Program Version:EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.14 08:43
Tabular Output Report in Format: HTML
Building: Small Hotel
Environment: Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650
Simulation Timestamp: 2015-09-14 08:44:12
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 3011.32 | 750.28 | 808.39 |
Net Site Energy | 3011.32 | 750.28 | 808.39 |
Total Source Energy | 7389.52 | 1841.13 | 1983.71 |
Net Source Energy | 7389.52 | 1841.13 | 1983.71 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4013.58 |
Net Conditioned Building Area | 3725.09 |
Unconditioned Building Area | 288.49 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 74.20 | 20.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 344.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 578.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 65.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 601.95 | 421.49 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 315.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 589.19 | 0.00 | 0.00 | 0.00 | 2578.25 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1980.44 | 1030.88 | 0.00 | 0.00 | 0.00 | 2578.25 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 74.20 | 20.20 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 344.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | General Lights | 578.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 65.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | General | 573.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ELECTRIC EQUIPMENT#Laundry#05 | 28.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
GAS EQUIPMENT#Laundry#05 | 0.00 | 421.49 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 315.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 589.19 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2578.25 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 172.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 197.19 | 163.59 | 0.00 | 0.00 | 0.00 | 0.69 |
Other | 161.59 | 113.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 531.65 | 276.74 | 0.00 | 0.00 | 0.00 | 0.69 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 160.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 183.02 | 151.83 | 0.00 | 0.00 | 0.00 | 0.64 |
Other | 149.98 | 105.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 493.43 | 256.85 | 0.00 | 0.00 | 0.00 | 0.64 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.00 | 0.00 |
High Temperature Geothermal* | 0.00 | 0.00 |
Photovoltaic Power | 0.00 | 0.00 |
Wind Power | 0.00 | 0.00 |
Net Decrease in On-Site Storage | 0.00 | 0.00 |
Total On-Site Electric Sources | 0.00 | 0.00 |
Electricity Coming From Utility | 1980.44 | 100.00 |
Surplus Electricity Going To Utility | 0.00 | 0.00 |
Net Electricity From Utility | 1980.44 | 100.00 |
Total On-Site and Utility Electric Sources | 1980.44 | 100.00 |
Total Electricity End Uses | 1980.44 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 2578.25 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 2578.25 | 100.00 |
Total Water End Uses | 2578.25 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 62.75 |
Time Setpoint Not Met During Occupied Cooling | 4450.25 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 5554.00 |
Table of Contents
TopMONTHLY INDOOR TEMP
| REARSTAIRSFLR1 | CORRIDORFLR1 | REARSTORAGEFLR1 | FRONTLOUNGEFLR1 | RESTROOMFLR1 | MEETINGROOMFLR1 | MECHANICALROOMFLR1 | GUESTROOM101 | GUESTROOM102 | GUESTROOM103 | GUESTROOM104 | GUESTROOM105 | EMPLOYEELOUNGEFLR1 | LAUNDRYROOMFLR1 | ELEVATORCOREFLR1 | EXERCISECENTERFLR1 | FRONTOFFICEFLR1 | FRONTSTAIRSFLR1 | FRONTSTORAGEFLR1 | REARSTAIRSFLR2 | CORRIDORFLR2 | REARSTORAGEFLR2 | GUESTROOM201 | GUESTROOM202_205 | GUESTROOM206_208 | GUESTROOM209_212 | GUESTROOM213 | GUESTROOM214 | GUESTROOM215_218 | ELEVATORCOREFLR2 | GUESTROOM219 | GUESTROOM220_223 | GUESTROOM224 | FRONTSTORAGEFLR2 | FRONTSTAIRSFLR2 | REARSTAIRSFLR3 | CORRIDORFLR3 | REARSTORAGEFLR3 | GUESTROOM301 | GUESTROOM302_305 | GUESTROOM306_308 | GUESTROOM309_312 | GUESTROOM313 | GUESTROOM314 | GUESTROOM315_318 | ELEVATORCOREFLR3 | GUESTROOM319 | GUESTROOM320_323 | GUESTROOM324 | FRONTSTORAGEFLR3 | FRONTSTAIRSFLR3 | REARSTAIRSFLR4 | CORRIDORFLR4 | REARSTORAGEFLR4 | GUESTROOM401 | GUESTROOM402_405 | GUESTROOM406_408 | GUESTROOM409_412 | GUESTROOM413 | GUESTROOM414 | GUESTROOM415_418 | ELEVATORCOREFLR4 | GUESTROOM419 | GUESTROOM420_423 | GUESTROOM424 | FRONTSTORAGEFLR4 | FRONTSTAIRSFLR4 |PEAK ELECTRICAL DEMAND
| Meter |PEAK GAS DEMAND
| Meter |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
GeneralValue | |
Program Version and Build | EnergyPlus-Linux--- 8.0.0.---, YMD=2015.09.14 08:43 |
RunPeriod | Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650 |
Weather File | Albuquerque Intl Arpt Isis NM USA TMY3 WMO#=723650 |
Latitude [deg] | 35.04 |
Longitude [deg] | -106.6 |
Elevation [m] | 1619.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1694.58 | 211.83 | 635.46 | 211.83 | 635.46 |
Window Opening Area [m2] | 184.20 | 8.38 | 72.38 | 6.62 | 96.82 |
Window-Wall Ratio [%] | 10.87 | 3.95 | 11.39 | 3.13 | 15.24 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1492.32 | 211.83 | 556.77 | 116.50 | 607.21 |
Window Opening Area [m2] | 179.26 | 8.38 | 67.45 | 6.62 | 96.82 |
Window-Wall Ratio [%] | 12.01 | 3.95 | 12.11 | 5.68 | 15.95 |
Total | |
Gross Roof Area [m2] | 1003.40 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Gross Wall Area [m2] | Window Glass Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
REARSTAIRSFLR1 | 20.07 | Yes | Yes | 67.30 | 1.00 | 35.77 | 0.00 | 8.3610 | 0.0000 | |
CORRIDORFLR1 | 150.51 | Yes | Yes | 504.62 | 1.00 | 32.70 | 9.82 | 6.9675 | 0.0000 | |
REARSTORAGEFLR1 | 20.07 | No | Yes | 67.30 | 1.00 | 35.77 | 0.00 | 11.1480 | 0.0000 | |
FRONTLOUNGEFLR1 | 163.06 | Yes | Yes | 546.70 | 1.00 | 94.02 | 14.83 | 15.3285 | 3.08 | 26.0600 |
RESTROOMFLR1 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 12.5415 | 32.61 | 0.0000 |
MEETINGROOMFLR1 | 80.27 | Yes | Yes | 269.14 | 1.00 | 32.70 | 4.94 | 18.1154 | 1.87 | 6.1800 |
MECHANICALROOMFLR1 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 0.00 | 20.9024 | 0.0000 | |
GUESTROOM101 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM102 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM103 | 32.61 | Yes | Yes | 109.34 | 1.00 | 13.29 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM104 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM105 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 11.8403 | 21.74 | 11.8935 |
EMPLOYEELOUNGEFLR1 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 16.7220 | 1.81 | 21.5100 |
LAUNDRYROOMFLR1 | 97.83 | No | Yes | 327.99 | 1.00 | 39.86 | 4.94 | 8.3610 | 8.89 | 437.5596 |
ELEVATORCOREFLR1 | 15.05 | No | Yes | 50.46 | 1.00 | 6.13 | 0.00 | 0.0000 | 2155.0206 | |
EXERCISECENTERFLR1 | 32.61 | Yes | Yes | 109.33 | 1.00 | 13.29 | 1.65 | 12.5415 | 4.66 | 18.5900 |
FRONTOFFICEFLR1 | 130.44 | Yes | Yes | 437.33 | 1.00 | 53.14 | 6.58 | 15.3285 | 13.04 | 13.7800 |
FRONTSTAIRSFLR1 | 20.07 | Yes | Yes | 67.28 | 1.00 | 35.77 | 0.00 | 8.3610 | 0.0000 | |
FRONTSTORAGEFLR1 | 12.54 | No | Yes | 42.05 | 1.00 | 5.11 | 0.00 | 11.1480 | 0.0000 | |
REARSTAIRSFLR2 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 8.3610 | 0.0000 | |
CORRIDORFLR2 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 2.62 | 6.9675 | 0.0000 | |
REARSTORAGEFLR2 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 11.1480 | 0.0000 | |
GUESTROOM201 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM202_205 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM206_208 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 6.70 | 11.8403 | 23.41 | 11.8935 |
GUESTROOM209_212 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM213 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM214 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM215_218 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
ELEVATORCOREFLR2 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM219 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM220_223 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM224 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
FRONTSTORAGEFLR2 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 11.1480 | 0.0000 | |
FRONTSTAIRSFLR2 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 8.3610 | 0.0000 | |
REARSTAIRSFLR3 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 8.3610 | 0.0000 | |
CORRIDORFLR3 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 2.62 | 6.9675 | 0.0000 | |
REARSTORAGEFLR3 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 11.1480 | 0.0000 | |
GUESTROOM301 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM302_305 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM306_308 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 6.70 | 11.8403 | 23.41 | 11.8935 |
GUESTROOM309_312 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM313 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM314 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM315_318 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
ELEVATORCOREFLR3 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM319 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM320_323 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM324 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
FRONTSTORAGEFLR3 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 11.1480 | 0.0000 | |
FRONTSTAIRSFLR3 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 8.3610 | 0.0000 | |
REARSTAIRSFLR4 | 20.07 | Yes | Yes | 55.06 | 1.00 | 29.27 | 0.00 | 8.3610 | 0.0000 | |
CORRIDORFLR4 | 125.42 | Yes | Yes | 344.05 | 1.00 | 18.39 | 2.62 | 6.9675 | 0.0000 | |
REARSTORAGEFLR4 | 20.07 | No | Yes | 55.07 | 1.00 | 29.27 | 0.00 | 11.1480 | 0.0000 | |
GUESTROOM401 | 32.61 | Yes | Yes | 89.46 | 1.00 | 33.45 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM402_405 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM406_408 | 105.36 | Yes | Yes | 289.02 | 1.00 | 35.12 | 6.70 | 11.8403 | 23.41 | 11.8935 |
GUESTROOM409_412 | 130.45 | Yes | Yes | 357.84 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM413 | 32.61 | Yes | Yes | 89.46 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM414 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM415_418 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
ELEVATORCOREFLR4 | 15.05 | No | Yes | 41.29 | 1.00 | 5.02 | 0.00 | 0.0000 | 0.0000 | |
GUESTROOM419 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM420_423 | 130.44 | Yes | Yes | 357.81 | 1.00 | 43.48 | 6.58 | 11.8403 | 21.74 | 11.8935 |
GUESTROOM424 | 32.61 | Yes | Yes | 89.45 | 1.00 | 10.87 | 1.65 | 11.8403 | 21.74 | 11.8935 |
FRONTSTORAGEFLR4 | 12.54 | No | Yes | 34.40 | 1.00 | 4.18 | 0.00 | 11.1480 | 0.0000 | |
FRONTSTAIRSFLR4 | 20.07 | Yes | Yes | 55.05 | 1.00 | 29.26 | 0.00 | 8.3610 | 0.0000 | |
Total | 4013.58 | 11621.73 | 1694.58 | 184.20 | 11.2819 | 15.53 | 28.2097 | |||
Conditioned Total | 3725.09 | 10741.65 | 1492.32 | 179.26 | 11.5457 | 15.05 | 10.1966 | |||
Unconditioned Total | 288.49 | 880.07 | 202.26 | 4.94 | 7.8766 | 26.23 | 260.8031 | |||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00 | -7.90 | Wetbulb [C] | 3.20 | 0.00 |
ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 13.50 | 15.70 | Wetbulb [C] | 4.40 | 220.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
W_REARSTAIRSFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 180.00 | 90.00 | S |
W_REARSTAIRSFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.18 | 90.00 | 90.00 | E |
S_REARSTAIRSFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 20.07 | 90.00 | 180.00 | |
W_CORRIDORFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.13 | 180.00 | 90.00 | S |
W_CORRIDORFLR1_10_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 90.00 | 90.00 | E |
W_CORRIDORFLR1_16_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.13 | 0.00 | 90.00 | N |
W_CORRIDORFLR1_20_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.22 | 270.00 | 90.00 | W |
S_CORRIDORFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 150.51 | 90.00 | 180.00 | |
W_REARSTORAGEFLR1_2_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 180.00 | 90.00 | S |
W_REARSTORAGEFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.18 | 270.00 | 90.00 | W |
S_REARSTORAGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 20.07 | 90.00 | 180.00 | |
W_FRONTLOUNGEFLR1_4_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 0.00 | 90.00 | N |
W_FRONTLOUNGEFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 66.43 | 270.00 | 90.00 | W |
S_FRONTLOUNGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 163.06 | 90.00 | 180.00 | |
W_RESTROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 270.00 | 90.00 | W |
S_RESTROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_MEETINGROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 32.70 | 270.00 | 90.00 | W |
S_MEETINGROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 80.27 | 90.00 | 180.00 | |
W_MECHANICALROOMFLR1_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 270.00 | 90.00 | W |
S_MECHANICALROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_GUESTROOM101_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 270.00 | 90.00 | W |
S_GUESTROOM101_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_GUESTROOM102_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 270.00 | 90.00 | W |
S_GUESTROOM102_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_GUESTROOM103_5_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 270.00 | 90.00 | W |
S_GUESTROOM103_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_GUESTROOM104_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 90.00 | 90.00 | E |
S_GUESTROOM104_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_GUESTROOM105_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 90.00 | 90.00 | E |
S_GUESTROOM105_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_EMPLOYEELOUNGEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 90.00 | 90.00 | E |
S_EMPLOYEELOUNGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_LAUNDRYROOMFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.86 | 90.00 | 90.00 | E |
S_LAUNDRYROOMFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 97.83 | 90.00 | 180.00 | |
W_ELEVATORCOREFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.13 | 90.00 | 90.00 | E |
S_ELEVATORCOREFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 15.05 | 90.00 | 180.00 | |
W_EXERCISECENTERFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 13.29 | 90.00 | 90.00 | E |
S_EXERCISECENTERFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 32.61 | 90.00 | 180.00 | |
W_FRONTOFFICEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 53.14 | 90.00 | 90.00 | E |
S_FRONTOFFICEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 130.44 | 90.00 | 180.00 | |
W_FRONTSTAIRSFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.18 | 90.00 | 90.00 | E |
W_FRONTSTAIRSFLR1_4_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 27.59 | 0.00 | 90.00 | N |
S_FRONTSTAIRSFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 20.07 | 90.00 | 180.00 | |
W_FRONTSTORAGEFLR1_3_0_0 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.11 | 90.00 | 90.00 | E |
S_FRONTSTORAGEFLR1_0_0_0 | EXT_SLAB_8IN_WITH_CARPET | 0.30 | 1.827 | 3.285 | 12.54 | 90.00 | 180.00 | |
W_REARSTAIRSFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 180.00 | 90.00 | S |
W_REARSTAIRSFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 90.00 | 90.00 | E |
W_CORRIDORFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 180.00 | 90.00 | S |
W_CORRIDORFLR2_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 90.00 | 90.00 | E |
W_CORRIDORFLR2_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 0.00 | 90.00 | N |
W_REARSTORAGEFLR2_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 180.00 | 90.00 | S |
W_REARSTORAGEFLR2_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 270.00 | 90.00 | W |
W_GUESTROOM201_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 0.00 | 90.00 | N |
W_GUESTROOM201_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 270.00 | 90.00 | W |
W_GUESTROOM202_205_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 270.00 | 90.00 | W |
W_GUESTROOM206_208_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 270.00 | 90.00 | W |
W_GUESTROOM209_212_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 270.00 | 90.00 | W |
W_GUESTROOM213_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 270.00 | 90.00 | W |
W_GUESTROOM214_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
W_GUESTROOM215_218_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 90.00 | 90.00 | E |
W_ELEVATORCOREFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 90.00 | 90.00 | E |
W_GUESTROOM219_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
W_GUESTROOM220_223_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 90.00 | 90.00 | E |
W_GUESTROOM224_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
W_FRONTSTORAGEFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 90.00 | 90.00 | E |
W_FRONTSTAIRSFLR2_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 90.00 | 90.00 | E |
W_FRONTSTAIRSFLR2_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 0.00 | 90.00 | N |
W_REARSTAIRSFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 180.00 | 90.00 | S |
W_REARSTAIRSFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 90.00 | 90.00 | E |
W_CORRIDORFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 180.00 | 90.00 | S |
W_CORRIDORFLR3_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 90.00 | 90.00 | E |
W_CORRIDORFLR3_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 0.00 | 90.00 | N |
W_REARSTORAGEFLR3_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 180.00 | 90.00 | S |
W_REARSTORAGEFLR3_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 270.00 | 90.00 | W |
W_GUESTROOM301_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 0.00 | 90.00 | N |
W_GUESTROOM301_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 270.00 | 90.00 | W |
W_GUESTROOM302_305_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 270.00 | 90.00 | W |
W_GUESTROOM306_308_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 270.00 | 90.00 | W |
W_GUESTROOM309_312_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 270.00 | 90.00 | W |
W_GUESTROOM313_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 270.00 | 90.00 | W |
W_GUESTROOM314_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
W_GUESTROOM315_318_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 90.00 | 90.00 | E |
W_ELEVATORCOREFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 90.00 | 90.00 | E |
W_GUESTROOM319_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
W_GUESTROOM320_323_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 90.00 | 90.00 | E |
W_GUESTROOM324_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
W_FRONTSTORAGEFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 90.00 | 90.00 | E |
W_FRONTSTAIRSFLR3_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 90.00 | 90.00 | E |
W_FRONTSTAIRSFLR3_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 0.00 | 90.00 | N |
W_REARSTAIRSFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 180.00 | 90.00 | S |
W_REARSTAIRSFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 90.00 | 90.00 | E |
R_REARSTAIRSFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 20.07 | 270.00 | 0.00 | |
W_CORRIDORFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 180.00 | 90.00 | S |
W_CORRIDORFLR4_9_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 8.36 | 90.00 | 90.00 | E |
W_CORRIDORFLR4_15_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 0.00 | 90.00 | N |
R_CORRIDORFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 125.42 | 270.00 | 0.00 | |
W_REARSTORAGEFLR4_2_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 180.00 | 90.00 | S |
W_REARSTORAGEFLR4_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 270.00 | 90.00 | W |
R_REARSTORAGEFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 20.07 | 270.00 | 0.00 | |
W_GUESTROOM401_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 0.00 | 90.00 | N |
W_GUESTROOM401_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 270.00 | 90.00 | W |
R_GUESTROOM401_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 270.00 | 0.00 | |
W_GUESTROOM402_405_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 270.00 | 90.00 | W |
R_GUESTROOM402_405_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.45 | 270.00 | 0.00 | |
W_GUESTROOM406_408_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 35.12 | 270.00 | 90.00 | W |
R_GUESTROOM406_408_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 105.36 | 270.00 | 0.00 | |
W_GUESTROOM409_412_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 270.00 | 90.00 | W |
R_GUESTROOM409_412_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.45 | 270.00 | 0.00 | |
W_GUESTROOM413_5_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 270.00 | 90.00 | W |
R_GUESTROOM413_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 270.00 | 0.00 | |
W_GUESTROOM414_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
R_GUESTROOM414_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 270.00 | 0.00 | |
W_GUESTROOM415_418_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 90.00 | 90.00 | E |
R_GUESTROOM415_418_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.44 | 270.00 | 0.00 | |
W_ELEVATORCOREFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 5.02 | 90.00 | 90.00 | E |
R_ELEVATORCOREFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 15.05 | 270.00 | 0.00 | |
W_GUESTROOM419_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
R_GUESTROOM419_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 270.00 | 0.00 | |
W_GUESTROOM420_423_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 43.48 | 90.00 | 90.00 | E |
R_GUESTROOM420_423_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 130.44 | 270.00 | 0.00 | |
W_GUESTROOM424_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 10.87 | 90.00 | 90.00 | E |
R_GUESTROOM424_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 32.61 | 270.00 | 0.00 | |
W_FRONTSTORAGEFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 4.18 | 90.00 | 90.00 | E |
R_FRONTSTORAGEFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 12.54 | 270.00 | 0.00 | |
W_FRONTSTAIRSFLR4_3_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 6.69 | 90.00 | 90.00 | E |
W_FRONTSTAIRSFLR4_4_0_0 | RES_EXT_WALL | 0.30 | 0.363 | 0.384 | 22.58 | 0.00 | 90.00 | N |
R_FRONTSTAIRSFLR4_1_0_0 | RES_ROOF | 0.23 | 0.269 | 0.283 | 20.07 | 270.00 | 0.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
W_CORRIDORFLR1_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 2.69 | 0.00 | 0.00 | 2.69 | 2.69 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR1_2_0_0 | 180.00 | 90.00 | S | ||
D_CORRIDORFLR1_16_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 4.44 | 0.00 | 0.00 | 4.44 | 4.44 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR1_16_0_0 | 0.00 | 90.00 | N | ||
W_CORRIDORFLR1_20_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 2.69 | 0.00 | 0.00 | 2.69 | 2.69 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR1_20_0_0 | 270.00 | 90.00 | W | ||
W_FRONTLOUNGEFLR1_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_FRONTLOUNGEFLR1_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_FRONTLOUNGEFLR1_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_FRONTLOUNGEFLR1_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_FRONTLOUNGEFLR1_5_0_0_0_4 | WINDOW_U_0.52_SHGC_0.40 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 2.653 | 0.426 | 0.308 | No | W_FRONTLOUNGEFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_MEETINGROOMFLR1_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_MEETINGROOMFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_MEETINGROOMFLR1_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_MEETINGROOMFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_MEETINGROOMFLR1_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_MEETINGROOMFLR1_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM101_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM101_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM102_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM102_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM103_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM103_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM104_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM104_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM105_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM105_3_0_0 | 90.00 | 90.00 | E | ||
W_EMPLOYEELOUNGEFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_EMPLOYEELOUNGEFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_LAUNDRYROOMFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_LAUNDRYROOMFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_LAUNDRYROOMFLR1_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_LAUNDRYROOMFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_LAUNDRYROOMFLR1_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_LAUNDRYROOMFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_EXERCISECENTERFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_EXERCISECENTERFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_FRONTOFFICEFLR1_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_FRONTOFFICEFLR1_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_FRONTOFFICEFLR1_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_FRONTOFFICEFLR1_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_FRONTOFFICEFLR1_3_0_0 | 90.00 | 90.00 | E | ||
W_CORRIDORFLR2_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR2_2_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR2_15_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR2_15_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM201_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM201_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM202_205_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM202_205_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM202_205_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM202_205_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM202_205_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM206_208_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM206_208_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM206_208_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM206_208_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM206_208_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM206_208_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM209_212_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM209_212_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM209_212_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM209_212_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM209_212_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM213_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM213_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM214_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM214_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM215_218_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM215_218_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM215_218_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM215_218_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM215_218_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM219_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM219_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM220_223_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM220_223_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM220_223_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM220_223_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM220_223_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM224_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM224_3_0_0 | 90.00 | 90.00 | E | ||
W_CORRIDORFLR3_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR3_2_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR3_15_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR3_15_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM301_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM301_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM302_305_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM302_305_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM302_305_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM302_305_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM302_305_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM306_308_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM306_308_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM306_308_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM306_308_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM306_308_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM306_308_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM309_312_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM309_312_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM309_312_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM309_312_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM309_312_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM313_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM313_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM314_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM314_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM315_318_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM315_318_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM315_318_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM315_318_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM315_318_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM319_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM319_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM320_323_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM320_323_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM320_323_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM320_323_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM320_323_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM324_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM324_3_0_0 | 90.00 | 90.00 | E | ||
W_CORRIDORFLR4_2_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR4_2_0_0 | 180.00 | 90.00 | S | ||
W_CORRIDORFLR4_15_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.31 | 0.00 | 0.00 | 1.31 | 1.31 | 2.653 | 0.426 | 0.308 | No | W_CORRIDORFLR4_15_0_0 | 0.00 | 90.00 | N | ||
W_GUESTROOM401_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM401_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM402_405_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM402_405_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM402_405_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM402_405_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM402_405_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM406_408_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM406_408_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM406_408_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM406_408_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM406_408_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 3.41 | 0.00 | 0.00 | 3.41 | 3.41 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM406_408_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM409_412_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM409_412_5_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM409_412_5_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM409_412_5_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM409_412_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM413_5_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM413_5_0_0 | 270.00 | 90.00 | W | ||
W_GUESTROOM414_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM414_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM415_418_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM415_418_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM415_418_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM415_418_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM415_418_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM419_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM419_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM420_423_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM420_423_3_0_0_0_1 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM420_423_3_0_0_0_2 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM420_423_3_0_0_0_3 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM420_423_3_0_0 | 90.00 | 90.00 | E | ||
W_GUESTROOM424_3_0_0_0_0 | WINDOW_U_0.52_SHGC_0.40 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.653 | 0.426 | 0.308 | No | W_GUESTROOM424_3_0_0 | 90.00 | 90.00 | E | ||
Total or Average | 184.20 | 2.653 | 0.426 | 0.308 | ||||||||||||
North Total or Average | 8.38 | 2.653 | 0.426 | 0.308 | ||||||||||||
Non-North Total or Average | 175.82 | 2.653 | 0.426 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
CORRIDORFLR1 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
101 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
102 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
103 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
104 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
105 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
CORRIDORFLR2 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
201 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
202_205 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
206_208 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7913.25 | 5780.50 | 2132.75 | 0.73 | 3.54 | |||
209_212 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
213 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
214 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
215_218 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
219 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
220_223 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
224 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
CORRIDORFLR3 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
301 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
302_305 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
306_308 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7913.25 | 5780.50 | 2132.75 | 0.73 | 3.54 | |||
309_312 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
313 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
314 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
315_318 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
319 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
320_323 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
324 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
CORRIDORFLR4 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
401 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
402_405 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
406_408 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7913.25 | 5780.50 | 2132.75 | 0.73 | 3.54 | |||
409_412 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
413 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
414 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
415_418 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
419 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
420_423 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10551.00 | 7707.33 | 2843.67 | 0.73 | 3.54 | |||
424 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2637.75 | 1926.83 | 710.92 | 0.73 | 3.54 | |||
SAC_FRONTOFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7677.84 | 6131.95 | 1545.89 | 0.80 | 3.91 | |||
SAC_FRONTLOUNGE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 20444.55 | 16328.15 | 4116.40 | 0.80 | 3.50 | |||
SAC_MEETINGROOM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9953.74 | 7616.68 | 2337.06 | 0.77 | 3.91 | |||
SAC_EXC_EMPLGE_RESTRM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 15620.65 | 12475.52 | 3145.14 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
CORRIDORFLR1 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
101 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
102 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
103 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
104 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
105 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
CORRIDORFLR2 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
201 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
202_205 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
206_208 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7610.9 | 3.00 | 10.24 | 10.86 | 10.31 |
209_212 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
213 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
214 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
215_218 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
219 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
220_223 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
224 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
CORRIDORFLR3 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
301 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
302_305 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
306_308 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7610.9 | 3.00 | 10.24 | 10.86 | 10.31 |
309_312 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
313 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
314 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
315_318 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
319 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
320_323 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
324 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
CORRIDORFLR4 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
401 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
402_405 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
406_408 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7610.9 | 3.00 | 10.24 | 10.86 | 10.31 |
409_412 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
413 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
414 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
415_418 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
419 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
420_423 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 10147.8 | 3.00 | 10.24 | 10.86 | 10.31 |
424 PTAC COOLING COIL | Coil:Cooling:DX:SingleSpeed | 2537.0 | 3.00 | 10.24 | 10.86 | 10.31 |
SAC_FRONTOFFICE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 7317.9 | 3.15 | 10.76 | 11.39 | 10.54 |
SAC_FRONTLOUNGE COOLING COIL | Coil:Cooling:DX:SingleSpeed | 19486.2 | 2.87 | 9.78 | 10.36 | 9.69 |
SAC_MEETINGROOM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 9529.5 | 3.21 | 10.96 | 11.60 | 10.83 |
SAC_EXC_EMPLGE_RESTRM COOLING COIL | Coil:Cooling:DX:SingleSpeed | 14888.4 | 3.15 | 10.76 | 11.39 | 10.54 |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
REARSTAIRSFLR1UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.34 | 1.00 | |
CORRIDORFLR1 PTAC HEATING COIL | Coil:Heating:Electric | 27386.18 | 1.00 | |
MECHRMUNITHEATERHEATINGCOIL | Coil:Heating:Electric | 0.00 | 1.00 | |
101 PTAC HEATING COIL | Coil:Heating:Electric | 423.36 | 1.00 | |
102 PTAC HEATING COIL | Coil:Heating:Electric | 423.36 | 1.00 | |
103 PTAC HEATING COIL | Coil:Heating:Electric | 999.93 | 1.00 | |
104 PTAC HEATING COIL | Coil:Heating:Electric | 885.97 | 1.00 | |
105 PTAC HEATING COIL | Coil:Heating:Electric | 787.84 | 1.00 | |
FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.28 | 1.00 | |
REARSTAIRSFLR2UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.34 | 1.00 | |
CORRIDORFLR2 PTAC HEATING COIL | Coil:Heating:Electric | 2234.52 | 1.00 | |
201 PTAC HEATING COIL | Coil:Heating:Electric | 787.90 | 1.00 | |
202_205 PTAC HEATING COIL | Coil:Heating:Electric | 3151.59 | 1.00 | |
206_208 PTAC HEATING COIL | Coil:Heating:Electric | 2497.75 | 1.00 | |
209_212 PTAC HEATING COIL | Coil:Heating:Electric | 3151.59 | 1.00 | |
213 PTAC HEATING COIL | Coil:Heating:Electric | 1076.53 | 1.00 | |
214 PTAC HEATING COIL | Coil:Heating:Electric | 960.45 | 1.00 | |
215_218 PTAC HEATING COIL | Coil:Heating:Electric | 3151.37 | 1.00 | |
219 PTAC HEATING COIL | Coil:Heating:Electric | 787.84 | 1.00 | |
220_223 PTAC HEATING COIL | Coil:Heating:Electric | 3151.37 | 1.00 | |
224 PTAC HEATING COIL | Coil:Heating:Electric | 892.10 | 1.00 | |
FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.28 | 1.00 | |
REARSTAIRSFLR3UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.34 | 1.00 | |
CORRIDORFLR3 PTAC HEATING COIL | Coil:Heating:Electric | 2591.35 | 1.00 | |
301 PTAC HEATING COIL | Coil:Heating:Electric | 787.90 | 1.00 | |
302_305 PTAC HEATING COIL | Coil:Heating:Electric | 3151.59 | 1.00 | |
306_308 PTAC HEATING COIL | Coil:Heating:Electric | 2497.75 | 1.00 | |
309_312 PTAC HEATING COIL | Coil:Heating:Electric | 3151.59 | 1.00 | |
313 PTAC HEATING COIL | Coil:Heating:Electric | 787.90 | 1.00 | |
314 PTAC HEATING COIL | Coil:Heating:Electric | 1079.93 | 1.00 | |
315_318 PTAC HEATING COIL | Coil:Heating:Electric | 3151.37 | 1.00 | |
319 PTAC HEATING COIL | Coil:Heating:Electric | 787.84 | 1.00 | |
320_323 PTAC HEATING COIL | Coil:Heating:Electric | 3151.37 | 1.00 | |
324 PTAC HEATING COIL | Coil:Heating:Electric | 787.84 | 1.00 | |
FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.28 | 1.00 | |
REARSTAIRSFLR4UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.34 | 1.00 | |
CORRIDORFLR4 PTAC HEATING COIL | Coil:Heating:Electric | 3789.48 | 1.00 | |
401 PTAC HEATING COIL | Coil:Heating:Electric | 1337.65 | 1.00 | |
402_405 PTAC HEATING COIL | Coil:Heating:Electric | 3151.59 | 1.00 | |
406_408 PTAC HEATING COIL | Coil:Heating:Electric | 2497.75 | 1.00 | |
409_412 PTAC HEATING COIL | Coil:Heating:Electric | 3810.72 | 1.00 | |
413 PTAC HEATING COIL | Coil:Heating:Electric | 1085.22 | 1.00 | |
414 PTAC HEATING COIL | Coil:Heating:Electric | 927.68 | 1.00 | |
415_418 PTAC HEATING COIL | Coil:Heating:Electric | 3735.04 | 1.00 | |
419 PTAC HEATING COIL | Coil:Heating:Electric | 1069.78 | 1.00 | |
420_423 PTAC HEATING COIL | Coil:Heating:Electric | 3601.43 | 1.00 | |
424 PTAC HEATING COIL | Coil:Heating:Electric | 1290.72 | 1.00 | |
FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | Coil:Heating:Electric | 264.28 | 1.00 | |
SAC_FRONTOFFICE HEATING COIL | Coil:Heating:Gas | 3244.22 | 0.80 | |
SAC_FRONTLOUNGE HEATING COIL | Coil:Heating:Gas | 13598.06 | 0.80 | |
SAC_MEETINGROOM HEATING COIL | Coil:Heating:Gas | 7281.66 | 0.80 | |
SAC_EXC_EMPLGE_RESTRM HEATING COIL | Coil:Heating:Gas | 5451.70 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | End Use | |
REARSTAIRSFLR1UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR1 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
MECHRMUNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.00 | 0.00 | 1.00 | General | |
101 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
102 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
103 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
104 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
105 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR1UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
REARSTAIRSFLR2UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR2 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
201 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
202_205 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
206_208 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.39 | 248.38 | 636.87 | 1.00 | General |
209_212 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
213 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
214 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
215_218 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
219 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
220_223 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
224 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR2UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
REARSTAIRSFLR3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR3 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
301 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
302_305 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
306_308 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.39 | 248.38 | 636.87 | 1.00 | General |
309_312 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
313 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
314 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
315_318 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
319 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
320_323 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
324 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
REARSTAIRSFLR4UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
CORRIDORFLR4 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
401 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
402_405 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
406_408 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.39 | 248.38 | 636.87 | 1.00 | General |
409_412 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
413 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
414 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
415_418 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
419 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
420_423 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.52 | 331.17 | 636.87 | 1.00 | General |
424 PTAC SUPPLY FAN | Fan:ConstantVolume | 0.52 | 331.17 | 0.13 | 82.79 | 636.87 | 1.00 | General |
FRONTSTAIRSFLR4UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.01 | 0.57 | 92.91 | 1.00 | General |
SAC_FRONTOFFICE SUPPLY FAN | Fan:ConstantVolume | 0.54 | 622.50 | 0.46 | 538.42 | 1160.84 | 1.00 | General |
SAC_FRONTLOUNGE SUPPLY FAN | Fan:ConstantVolume | 0.55 | 622.50 | 1.24 | 1408.10 | 1140.11 | 1.00 | General |
SAC_MEETINGROOM SUPPLY FAN | Fan:OnOff | 0.54 | 622.50 | 0.55 | 634.52 | 1160.84 | 1.00 | General |
SAC_EXC_EMPLGE_RESTRM SUPPLY FAN | Fan:ConstantVolume | 0.55 | 622.50 | 0.94 | 1075.86 | 1140.11 | 1.00 | General |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | |
SHWSYSSHOWER PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.0002 | 8.11 | 45084.46 | 0.85 |
SHWSYSLAUNDRY PUMP | Pump:ConstantSpeed | Intermittent | 0.00 | 0.0001 | 0.00 | 0.00 | 0.30 |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHWSYSSHOWER WATER HEATER | WaterHeater:Mixed | 1.14 | 87921.32 | 0.80 | 0.51 | 0.27 |
SHWSYSLAUNDRY WATER HEATER | WaterHeater:Mixed | 0.76 | 58614.21 | 0.81 | 0.80 | 0.51 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
Zone CoolingCalculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
FRONTLOUNGEFLR1 | 10269.00 | 12322.80 | 1.029 | 1.235 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
RESTROOMFLR1 | 708.31 | 849.97 | 0.071 | 0.085 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
MEETINGROOMFLR1 | 4541.65 | 5449.98 | 0.456 | 0.547 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
GUESTROOM101 | 578.12 | 693.74 | 0.061 | 0.074 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM102 | 441.59 | 529.91 | 0.047 | 0.056 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM103 | 1542.32 | 1850.78 | 0.215 | 0.258 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM104 | 1398.39 | 1678.07 | 0.195 | 0.234 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM105 | 1837.80 | 2205.36 | 0.256 | 0.307 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
EMPLOYEELOUNGEFLR1 | 5775.88 | 6931.06 | 0.579 | 0.695 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
EXERCISECENTERFLR1 | 1361.43 | 1633.72 | 0.136 | 0.164 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 27.68 | 0.00565 |
FRONTOFFICEFLR1 | 3859.45 | 4631.34 | 0.387 | 0.464 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
GUESTROOM201 | 895.05 | 1074.06 | 0.095 | 0.114 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
GUESTROOM202_205 | 6086.61 | 7303.93 | 0.848 | 1.017 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM206_208 | 4985.46 | 5982.55 | 0.694 | 0.833 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM209_212 | 5682.91 | 6819.49 | 0.791 | 0.950 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM213 | 1653.23 | 1983.87 | 0.230 | 0.276 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM214 | 1628.80 | 1954.57 | 0.227 | 0.272 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM215_218 | 8890.78 | 10668.93 | 0.943 | 1.132 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
GUESTROOM219 | 5794.68 | 6953.62 | 0.807 | 0.968 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
GUESTROOM220_223 | 5442.95 | 6531.54 | 0.758 | 0.910 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
GUESTROOM224 | 1636.20 | 1963.44 | 0.228 | 0.273 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:30:00 | 30.98 | 0.00565 |
GUESTROOM301 | 761.07 | 913.28 | 0.081 | 0.097 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:15:00 | 32.87 | 0.00565 |
GUESTROOM302_305 | 2103.22 | 2523.87 | 0.223 | 0.268 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM306_308 | 1904.90 | 2285.88 | 0.202 | 0.242 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM309_312 | 5700.82 | 6840.99 | 0.794 | 0.953 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM313 | 714.91 | 857.89 | 0.076 | 0.091 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
GUESTROOM314 | 1554.27 | 1865.12 | 0.216 | 0.260 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM315_318 | 6128.30 | 7353.96 | 0.853 | 1.024 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM319 | 894.28 | 1073.14 | 0.095 | 0.114 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM320_323 | 5263.69 | 6316.43 | 0.733 | 0.880 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM324 | 573.51 | 688.22 | 0.061 | 0.073 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 10:45:00 | 31.49 | 0.00565 |
GUESTROOM401 | 2133.34 | 2560.01 | 0.297 | 0.356 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.75 | 0.00565 |
GUESTROOM402_405 | 3182.73 | 3819.28 | 0.338 | 0.405 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.75 | 0.00565 |
GUESTROOM406_408 | 2871.54 | 3445.85 | 0.305 | 0.366 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 33.48 | 0.00565 |
GUESTROOM409_412 | 7039.68 | 8447.61 | 0.980 | 1.176 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 16:30:00 | 33.75 | 0.00565 |
GUESTROOM413 | 1090.44 | 1308.52 | 0.116 | 0.139 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 16:45:00 | 33.48 | 0.00565 |
GUESTROOM414 | 871.31 | 1045.58 | 0.092 | 0.111 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 14:45:00 | 35.10 | 0.00565 |
GUESTROOM415_418 | 6593.63 | 7912.36 | 0.918 | 1.102 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 11:00:00 | 32.00 | 0.00565 |
GUESTROOM419 | 1814.49 | 2177.39 | 0.253 | 0.303 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 32.67 | 0.00565 |
GUESTROOM420_423 | 6446.31 | 7735.57 | 0.898 | 1.077 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 11:15:00 | 32.33 | 0.00565 |
GUESTROOM424 | 1855.99 | 2227.19 | 0.258 | 0.310 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 11:30:00 | 32.67 | 0.00565 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
CORRIDORFLR1 | 18073.50 | 21688.20 | 1.809 | 2.171 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 18:00:00 | 31.86 | 0.00565 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
CORRIDORFLR2 | 3088.30 | 3705.96 | 0.309 | 0.371 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 32.54 | 0.00565 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
CORRIDORFLR3 | 1816.55 | 2179.86 | 0.182 | 0.218 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 17:45:00 | 32.20 | 0.00565 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 | |
CORRIDORFLR4 | 2902.82 | 3483.38 | 0.291 | 0.349 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 35.10 | 0.00565 |
FRONTSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN CLG .4% CONDNS DB=>MWB | 35.10 | 0.00565 |
Calculated Design Load [W] | User Design Load [W] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak | Temperature at Peak [C] | Humidity Ratio at Peak [kgWater/kgAir] | |
FRONTLOUNGEFLR1 | 1448.49 | 1738.19 | 0.050 | 0.236 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 07:15:00 | -7.90 | 0.00234 |
RESTROOMFLR1 | 10.88 | 13.05 | 0.000 | 0.000 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 07:45:00 | -7.90 | 0.00234 |
MEETINGROOMFLR1 | 489.07 | 586.88 | 0.017 | 0.126 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 07:00:00 | -7.90 | 0.00234 |
GUESTROOM101 | 0.00 | 0.00 | 0.000 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
GUESTROOM102 | 0.00 | 0.00 | 0.000 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
GUESTROOM103 | 504.29 | 605.15 | 0.017 | 0.021 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 07:30:00 | -7.90 | 0.00234 |
GUESTROOM104 | 409.35 | 491.22 | 0.014 | 0.017 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 07:45:00 | -7.90 | 0.00234 |
GUESTROOM105 | 275.13 | 330.16 | 0.009 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 08:30:00 | -7.90 | 0.00234 |
EMPLOYEELOUNGEFLR1 | 247.41 | 296.89 | 0.008 | 0.051 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -7.90 | 0.00234 |
EXERCISECENTERFLR1 | 126.86 | 152.23 | 0.004 | 0.043 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 06:00:00 | -7.90 | 0.00234 |
FRONTOFFICEFLR1 | 870.73 | 1044.88 | 0.030 | 0.056 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 06:30:00 | -7.90 | 0.00234 |
GUESTROOM201 | 195.15 | 234.17 | 0.006 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 11:15:00 | -7.90 | 0.00234 |
GUESTROOM202_205 | 1127.77 | 1353.33 | 0.039 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 10:45:00 | -7.90 | 0.00234 |
GUESTROOM206_208 | 827.75 | 993.30 | 0.028 | 0.043 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
GUESTROOM209_212 | 870.77 | 1044.93 | 0.030 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -7.90 | 0.00234 |
GUESTROOM213 | 568.12 | 681.75 | 0.019 | 0.023 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 11:00:00 | -7.90 | 0.00234 |
GUESTROOM214 | 471.41 | 565.70 | 0.016 | 0.019 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 10:15:00 | -7.90 | 0.00234 |
GUESTROOM215_218 | 64.04 | 76.85 | 0.002 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | -7.90 | 0.00234 |
GUESTROOM219 | 239.01 | 286.81 | 0.008 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -7.90 | 0.00234 |
GUESTROOM220_223 | 746.81 | 896.18 | 0.026 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 08:15:00 | -7.90 | 0.00234 |
GUESTROOM224 | 414.46 | 497.35 | 0.014 | 0.017 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:15:00 | -7.90 | 0.00234 |
GUESTROOM301 | 267.85 | 321.42 | 0.009 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 17:30:00 | -7.90 | 0.00234 |
GUESTROOM302_305 | 486.37 | 583.64 | 0.015 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 17:30:00 | -7.90 | 0.00234 |
GUESTROOM306_308 | 380.55 | 456.66 | 0.012 | 0.043 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 13:45:00 | -7.90 | 0.00234 |
GUESTROOM309_312 | 1096.22 | 1315.47 | 0.038 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 15:30:00 | -7.90 | 0.00234 |
GUESTROOM313 | 332.82 | 399.39 | 0.011 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 20:30:00 | -7.90 | 0.00234 |
GUESTROOM314 | 570.98 | 685.18 | 0.020 | 0.023 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 15:30:00 | -7.90 | 0.00234 |
GUESTROOM315_318 | 1145.53 | 1374.64 | 0.039 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 13:15:00 | -7.90 | 0.00234 |
GUESTROOM319 | 33.51 | 40.22 | 0.001 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 12:45:00 | -7.90 | 0.00234 |
GUESTROOM320_323 | 971.01 | 1165.21 | 0.033 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 13:15:00 | -7.90 | 0.00234 |
GUESTROOM324 | 163.21 | 195.85 | 0.005 | 0.013 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | -7.90 | 0.00234 |
GUESTROOM401 | 785.73 | 942.87 | 0.027 | 0.032 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 22:15:00 | -7.90 | 0.00234 |
GUESTROOM402_405 | 1266.17 | 1519.40 | 0.040 | 0.054 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 21:45:00 | -7.90 | 0.00234 |
GUESTROOM406_408 | 1048.99 | 1258.78 | 0.033 | 0.043 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 19:00:00 | -7.90 | 0.00234 |
GUESTROOM409_412 | 1859.67 | 2231.60 | 0.064 | 0.076 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 19:45:00 | -7.90 | 0.00234 |
GUESTROOM413 | 600.57 | 720.68 | 0.019 | 0.023 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 23:30:00 | -7.90 | 0.00234 |
GUESTROOM414 | 469.31 | 563.17 | 0.015 | 0.018 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 20:15:00 | -7.90 | 0.00234 |
GUESTROOM415_418 | 1796.70 | 2156.04 | 0.062 | 0.074 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 17:15:00 | -7.90 | 0.00234 |
GUESTROOM419 | 562.52 | 675.03 | 0.019 | 0.023 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 18:15:00 | -7.90 | 0.00234 |
GUESTROOM420_423 | 1685.35 | 2022.42 | 0.058 | 0.069 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 18:45:00 | -7.90 | 0.00234 |
GUESTROOM424 | 746.64 | 895.97 | 0.026 | 0.031 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | -7.90 | 0.00234 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
CORRIDORFLR1 | 21690.18 | 26028.21 | 0.743 | 0.891 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 08:15:00 | -7.90 | 0.00234 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
CORRIDORFLR2 | 799.66 | 959.60 | 0.027 | 0.038 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 09:45:00 | -7.90 | 0.00234 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
CORRIDORFLR3 | 1226.48 | 1471.78 | 0.042 | 0.050 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 13:30:00 | -7.90 | 0.00234 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 | |
CORRIDORFLR4 | 2224.93 | 2669.92 | 0.076 | 0.092 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | 12/21 13:30:00 | -7.90 | 0.00234 |
FRONTSTAIRSFLR4 | 0.00 | 0.00 | 0.000 | 0.006 | ALBUQUERQUE INTL ARPT ISIS ANN HTG 99.6% CONDNS DB | -7.90 | 0.00234 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | |
SAC_FRONTOFFICE | 0.46 | 0.46 | 0.06 | 0.06 |
SAC_FRONTLOUNGE | 1.24 | 1.24 | 0.24 | 0.24 |
SAC_MEETINGROOM | 0.55 | 0.55 | 0.13 | 0.13 |
SAC_EXC_EMPLGE_RESTRM | 0.94 | 0.94 | 0.09 | 0.09 |
Report: System Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
SAC_FRONTLOUNGE OA CONTROLLER | DifferentialDryBulb | 0.24 | 1.24 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
FRONTLOUNGEFLR1 | 1990.75 | 6019.50 | 499.00 |
RESTROOMFLR1 | 651.25 | 6382.50 | 0.25 |
MEETINGROOMFLR1 | 1443.00 | 2298.75 | 45.50 |
GUESTROOM101 | 0.00 | 0.00 | 0.00 |
GUESTROOM102 | 0.00 | 0.00 | 0.00 |
GUESTROOM103 | 257.25 | 8742.75 | 257.25 |
GUESTROOM104 | 21.00 | 8640.50 | 21.00 |
GUESTROOM105 | 0.00 | 8182.50 | 0.00 |
EMPLOYEELOUNGEFLR1 | 3047.75 | 2043.00 | 217.75 |
EXERCISECENTERFLR1 | 1859.75 | 2533.25 | 0.25 |
FRONTOFFICEFLR1 | 1477.00 | 5265.25 | 7.00 |
GUESTROOM201 | 0.00 | 0.00 | 0.00 |
GUESTROOM202_205 | 35.00 | 8259.00 | 31.00 |
GUESTROOM206_208 | 12.75 | 8252.25 | 7.00 |
GUESTROOM209_212 | 4.50 | 8461.75 | 2.00 |
GUESTROOM213 | 278.50 | 8619.75 | 278.50 |
GUESTROOM214 | 10.25 | 8173.50 | 10.25 |
GUESTROOM215_218 | 0.00 | 0.00 | 0.00 |
GUESTROOM219 | 4480.75 | 3946.75 | 873.00 |
GUESTROOM220_223 | 17.50 | 7935.00 | 0.00 |
GUESTROOM224 | 10.50 | 8099.75 | 10.50 |
GUESTROOM301 | 0.00 | 0.00 | 0.00 |
GUESTROOM302_305 | 0.00 | 0.00 | 0.00 |
GUESTROOM306_308 | 0.00 | 0.00 | 0.00 |
GUESTROOM309_312 | 35.25 | 8484.50 | 32.50 |
GUESTROOM313 | 0.00 | 0.00 | 0.00 |
GUESTROOM314 | 135.00 | 8180.50 | 135.00 |
GUESTROOM315_318 | 36.75 | 7832.00 | 0.00 |
GUESTROOM319 | 0.00 | 0.00 | 0.00 |
GUESTROOM320_323 | 8.25 | 8082.25 | 1.00 |
GUESTROOM324 | 0.00 | 0.00 | 0.00 |
GUESTROOM401 | 2521.25 | 7914.25 | 2244.50 |
GUESTROOM402_405 | 0.00 | 0.00 | 0.00 |
GUESTROOM406_408 | 0.00 | 0.00 | 0.00 |
GUESTROOM409_412 | 1008.50 | 7629.50 | 475.00 |
GUESTROOM413 | 0.00 | 0.00 | 0.00 |
GUESTROOM414 | 0.00 | 0.00 | 0.00 |
GUESTROOM415_418 | 984.00 | 7377.75 | 216.75 |
GUESTROOM419 | 716.00 | 7613.25 | 232.50 |
GUESTROOM420_423 | 998.75 | 7413.00 | 258.50 |
GUESTROOM424 | 1292.50 | 7682.50 | 802.25 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR1 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR2 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR3 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR4 | 0.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR4 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR1 | 0.00 | 0.00 | 0.00 |
MECHANICALROOMFLR1 | 0.00 | 0.00 | 0.00 |
LAUNDRYROOMFLR1 | 2920.00 | 2920.00 | 2920.00 |
ELEVATORCOREFLR1 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR1 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR2 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR2 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR2 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR3 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR3 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR3 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR4 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR4 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR4 | 0.00 | 0.00 | 0.00 |
Facility | 7300.00 | 8760.00 | 5554.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
FRONTLOUNGEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
RESTROOMFLR1 | 0.00 | 1269.25 | 0.00 | 1269.25 |
MEETINGROOMFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM101 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM102 | 0.00 | 0.25 | 0.00 | 0.00 |
GUESTROOM103 | 1.00 | 33.00 | 1.00 | 33.00 |
GUESTROOM104 | 0.00 | 32.50 | 0.00 | 32.50 |
GUESTROOM105 | 0.00 | 37.25 | 0.00 | 37.25 |
EMPLOYEELOUNGEFLR1 | 75.25 | 1247.25 | 57.50 | 655.25 |
EXERCISECENTERFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTOFFICEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM201 | 0.25 | 0.00 | 0.00 | 0.00 |
GUESTROOM202_205 | 0.25 | 23.00 | 0.25 | 23.00 |
GUESTROOM206_208 | 0.00 | 31.75 | 0.00 | 31.75 |
GUESTROOM209_212 | 0.00 | 18.75 | 0.00 | 18.75 |
GUESTROOM213 | 0.50 | 24.50 | 0.50 | 24.50 |
GUESTROOM214 | 0.00 | 24.00 | 0.00 | 24.00 |
GUESTROOM215_218 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM219 | 0.00 | 3363.25 | 0.00 | 3363.25 |
GUESTROOM220_223 | 0.00 | 17.75 | 0.00 | 17.75 |
GUESTROOM224 | 0.00 | 23.00 | 0.00 | 23.00 |
GUESTROOM301 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM302_305 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM306_308 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM309_312 | 0.00 | 18.75 | 0.00 | 18.75 |
GUESTROOM313 | 0.25 | 0.00 | 0.00 | 0.00 |
GUESTROOM314 | 1.50 | 23.25 | 1.50 | 23.25 |
GUESTROOM315_318 | 0.00 | 20.50 | 0.00 | 20.50 |
GUESTROOM319 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM320_323 | 0.00 | 17.00 | 0.00 | 17.00 |
GUESTROOM324 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM401 | 2.75 | 43.50 | 2.75 | 43.50 |
GUESTROOM402_405 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM406_408 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM409_412 | 0.25 | 33.25 | 0.25 | 33.25 |
GUESTROOM413 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM414 | 0.00 | 0.00 | 0.00 | 0.00 |
GUESTROOM415_418 | 0.00 | 27.75 | 0.00 | 27.75 |
GUESTROOM419 | 0.00 | 33.75 | 0.00 | 33.75 |
GUESTROOM420_423 | 0.25 | 26.50 | 0.25 | 26.50 |
GUESTROOM424 | 1.25 | 34.25 | 1.25 | 34.25 |
REARSTAIRSFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR1 | 0.25 | 3660.00 | 0.00 | 0.00 |
FRONTSTAIRSFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR2 | 0.00 | 291.75 | 0.00 | 0.00 |
FRONTSTAIRSFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR3 | 0.00 | 0.50 | 0.00 | 0.00 |
FRONTSTAIRSFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTAIRSFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDORFLR4 | 0.00 | 575.25 | 0.00 | 0.00 |
FRONTSTAIRSFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
MECHANICALROOMFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRYROOMFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR1 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR2 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR3 | 0.00 | 0.00 | 0.00 | 0.00 |
REARSTORAGEFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
ELEVATORCOREFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
FRONTSTORAGEFLR4 | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 81.00 | 5518.50 | 62.75 | 4450.25 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2015-09-14 08:44:12
ZoneHVAC:UnitHeaterMaximum Supply Air Flow Rate [m3/s] | |
REARSTAIRSFLR1 UNITHEATER | 0.006116 |
MECHRM UNITHEATER | 0.000000 |
FRONTSTAIRSFLR1 UNITHEATER | 0.006114 |
REARSTAIRSFLR2 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR2 UNITHEATER | 0.006114 |
REARSTAIRSFLR3 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR3 UNITHEATER | 0.006114 |
REARSTAIRSFLR4 UNITHEATER | 0.006116 |
FRONTSTAIRSFLR4 UNITHEATER | 0.006114 |
Maximum Flow Rate [m3/s] | |
REARSTAIRSFLR1UNITHEATERFAN | 0.006116 |
MECHRMUNITHEATERFAN | 0.000000 |
FRONTSTAIRSFLR1UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR2UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR2UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR3UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR3UNITHEATERFAN | 0.006114 |
REARSTAIRSFLR4UNITHEATERFAN | 0.006116 |
FRONTSTAIRSFLR4UNITHEATERFAN | 0.006114 |
SAC_FRONTOFFICE SUPPLY FAN | 0.463819 |
SAC_FRONTLOUNGE SUPPLY FAN | 1.24 |
SAC_EXC_EMPLGE_RESTRM SUPPLY FAN | 0.943644 |
Nominal Capacity [W] | |
REARSTAIRSFLR1UNITHEATERHEATINGCOIL | 264.34 |
CORRIDORFLR1 PTAC HEATING COIL | 27386.18 |
MECHRMUNITHEATERHEATINGCOIL | 0.000000 |
101 PTAC HEATING COIL | 423.36 |
102 PTAC HEATING COIL | 423.36 |
103 PTAC HEATING COIL | 999.93 |
104 PTAC HEATING COIL | 885.97 |
105 PTAC HEATING COIL | 787.84 |
FRONTSTAIRSFLR1UNITHEATERHEATINGCOIL | 264.28 |
REARSTAIRSFLR2UNITHEATERHEATINGCOIL | 264.34 |
CORRIDORFLR2 PTAC HEATING COIL | 2234.52 |
201 PTAC HEATING COIL | 787.90 |
202_205 PTAC HEATING COIL | 3151.59 |
206_208 PTAC HEATING COIL | 2497.75 |
209_212 PTAC HEATING COIL | 3151.59 |
213 PTAC HEATING COIL | 1076.53 |
214 PTAC HEATING COIL | 960.45 |
215_218 PTAC HEATING COIL | 3151.37 |
219 PTAC HEATING COIL | 787.84 |
220_223 PTAC HEATING COIL | 3151.37 |
224 PTAC HEATING COIL | 892.10 |
FRONTSTAIRSFLR2UNITHEATERHEATINGCOIL | 264.28 |
REARSTAIRSFLR3UNITHEATERHEATINGCOIL | 264.34 |
CORRIDORFLR3 PTAC HEATING COIL | 2591.35 |
301 PTAC HEATING COIL | 787.90 |
302_305 PTAC HEATING COIL | 3151.59 |
306_308 PTAC HEATING COIL | 2497.75 |
309_312 PTAC HEATING COIL | 3151.59 |
313 PTAC HEATING COIL | 787.90 |
314 PTAC HEATING COIL | 1079.93 |
315_318 PTAC HEATING COIL | 3151.37 |
319 PTAC HEATING COIL | 787.84 |
320_323 PTAC HEATING COIL | 3151.37 |
324 PTAC HEATING COIL | 787.84 |
FRONTSTAIRSFLR3UNITHEATERHEATINGCOIL | 264.28 |
REARSTAIRSFLR4UNITHEATERHEATINGCOIL | 264.34 |
CORRIDORFLR4 PTAC HEATING COIL | 3789.48 |
401 PTAC HEATING COIL | 1337.65 |
402_405 PTAC HEATING COIL | 3151.59 |
406_408 PTAC HEATING COIL | 2497.75 |
409_412 PTAC HEATING COIL | 3810.72 |
413 PTAC HEATING COIL | 1085.22 |
414 PTAC HEATING COIL | 927.68 |
415_418 PTAC HEATING COIL | 3735.04 |
419 PTAC HEATING COIL | 1069.78 |
420_423 PTAC HEATING COIL | 3601.43 |
424 PTAC HEATING COIL | 1290.72 |
FRONTSTAIRSFLR4UNITHEATERHEATINGCOIL | 264.28 |
Rated Sensible Heat Ratio | Rated Air Flow Rate [m3/s] | Rated Total Cooling Capacity (gross) [W] | |
CORRIDORFLR1 PTAC COOLING COIL | 0.730484 | ||
101 PTAC COOLING COIL | 0.730484 | ||
102 PTAC COOLING COIL | 0.730484 | ||
103 PTAC COOLING COIL | 0.730484 | ||
104 PTAC COOLING COIL | 0.730484 | ||
105 PTAC COOLING COIL | 0.730484 | ||
CORRIDORFLR2 PTAC COOLING COIL | 0.730484 | ||
201 PTAC COOLING COIL | 0.730484 | ||
202_205 PTAC COOLING COIL | 0.730484 | ||
206_208 PTAC COOLING COIL | 0.730484 | ||
209_212 PTAC COOLING COIL | 0.730484 | ||
213 PTAC COOLING COIL | 0.730484 | ||
214 PTAC COOLING COIL | 0.730484 | ||
215_218 PTAC COOLING COIL | 0.730484 | ||
219 PTAC COOLING COIL | 0.730484 | ||
220_223 PTAC COOLING COIL | 0.730484 | ||
224 PTAC COOLING COIL | 0.730484 | ||
CORRIDORFLR3 PTAC COOLING COIL | 0.730484 | ||
301 PTAC COOLING COIL | 0.730484 | ||
302_305 PTAC COOLING COIL | 0.730484 | ||
306_308 PTAC COOLING COIL | 0.730484 | ||
309_312 PTAC COOLING COIL | 0.730484 | ||
313 PTAC COOLING COIL | 0.730484 | ||
314 PTAC COOLING COIL | 0.730484 | ||
315_318 PTAC COOLING COIL | 0.730484 | ||
319 PTAC COOLING COIL | 0.730484 | ||
320_323 PTAC COOLING COIL | 0.730484 | ||
324 PTAC COOLING COIL | 0.730484 | ||
CORRIDORFLR4 PTAC COOLING COIL | 0.730484 | ||
401 PTAC COOLING COIL | 0.730484 | ||
402_405 PTAC COOLING COIL | 0.730484 | ||
406_408 PTAC COOLING COIL | 0.730484 | ||
409_412 PTAC COOLING COIL | 0.730484 | ||
413 PTAC COOLING COIL | 0.730484 | ||
414 PTAC COOLING COIL | 0.730484 | ||
415_418 PTAC COOLING COIL | 0.730484 | ||
419 PTAC COOLING COIL | 0.730484 | ||
420_423 PTAC COOLING COIL | 0.730484 | ||
424 PTAC COOLING COIL | 0.730484 | ||
SAC_FRONTOFFICE COOLING COIL | 0.798655 | 0.463819 | 7677.84 |
SAC_FRONTLOUNGE COOLING COIL | 0.798655 | 1.24 | 20444.55 |
SAC_MEETINGROOM COOLING COIL | 0.765208 | 0.546602 | 9953.74 |
SAC_EXC_EMPLGE_RESTRM COOLING COIL | 0.798655 | 0.943644 | 15620.65 |
Maximum Air Flow Rate [m3/s] | |
FRONTLOUNGEFLR1 DIRECT AIR | 1.24 |
RESTROOMFLR1 DIRECT AIR | 0.085109 |
MEETINGROOMFLR1 DIRECT AIR | 0.546602 |
EMPLOYEELOUNGEFLR1 DIRECT AIR | 0.694862 |
EXERCISECENTERFLR1 DIRECT AIR | 0.163673 |
FRONTOFFICEFLR1 DIRECT AIR | 0.463819 |
Maximum Flow Rate [m3/s] | |
SAC_FRONTOFFICE MAIN BRANCH | 0.463819 |
SAC_FRONTLOUNGE MAIN BRANCH | 1.24 |
SAC_MEETINGROOM MAIN BRANCH | 0.546602 |
SAC_EXC_EMPLGE_RESTRM MAIN BRANCH | 0.943644 |
Design Supply Air Flow Rate [m3/s] | |
SAC_FRONTOFFICE | 0.463819 |
SAC_FRONTLOUNGE | 1.24 |
SAC_MEETINGROOM | 0.546602 |
SAC_EXC_EMPLGE_RESTRM | 0.943644 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
SAC_FRONTOFFICE OA CONTROLLER | 0.463819 | 0.056300 |
SAC_FRONTLOUNGE OA CONTROLLER | 1.24 | 0.235982 |
SAC_MEETINGROOM OA CONTROLLER | 0.546602 | 0.126367 |
SAC_EXC_EMPLGE_RESTRM OA CONTROLLER | 0.943644 | 0.094386 |
Supply Air Flow Rate [m3/s] | Supply Air Flow Rate During Heating Operation [m3/s] | Supply Air Flow Rate During Cooling Operation [m3/s] | Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] | Nominal Heating Capacity [W] | Nominal Cooling Capacity [W] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
SAC_FRONTOFFICE | 0.463819 | 0.463819 | 0.463819 | 0.463819 | 3244.22 | 7677.84 | 1.00 |
SAC_FRONTLOUNGE | 1.24 | 1.24 | 1.24 | 1.24 | 13598.06 | 20444.55 | 1.00 |
SAC_MEETINGROOM | 0.546602 | 0.546602 | 0.546602 | 0.546602 | 7281.66 | 9953.74 | 1.00 |
SAC_EXC_EMPLGE_RESTRM | 0.943644 | 0.943644 | 0.943644 | 0.943644 | 5451.70 | 15620.65 | 0.173448 |
Nominal Capacity [W] | |
SAC_FRONTOFFICE HEATING COIL | 3244.22 |
SAC_FRONTLOUNGE HEATING COIL | 13598.06 |
SAC_MEETINGROOM HEATING COIL | 7281.66 |
SAC_EXC_EMPLGE_RESTRM HEATING COIL | 5451.70 |
Maximum Flow Rate [m3/s] | |
SAC_MEETINGROOM SUPPLY FAN | 0.546602 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SHWSYSSHOWER | 0.000180 | 0.202443 |
SHWSYSLAUNDRY | 0.000129 | 0.145496 |
Use Side Design Flow Rate [m3/s] | |
SHWSYSSHOWER WATER HEATER | 0.000180 |
SHWSYSLAUNDRY WATER HEATER | 0.000129 |
Rated Flow Rate [m3/s] | Rated Power Consumption [W] | |
SHWSYSSHOWER PUMP | 0.000180 | 8.11 |
SHWSYSLAUNDRY PUMP | 0.000129 | 0.000001 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.22 | 2.60 |
February | 19.31 | 4.29 |
March | 20.27 | 8.77 |
April | 21.95 | 13.91 |
May | 22.92 | 17.82 |
June | 24.57 | 23.21 |
July | 25.41 | 25.63 |
August | 25.02 | 24.08 |
September | 24.16 | 20.49 |
October | 22.48 | 13.71 |
November | 20.57 | 6.96 |
December | 19.42 | 2.07 |
Annual Sum or Average | 22.12 | 13.68 |
Minimum of Months | 19.22 | 2.07 |
Maximum of Months | 25.41 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.87 | 2.60 |
February | 23.08 | 4.29 |
March | 23.61 | 8.77 |
April | 24.35 | 13.91 |
May | 25.01 | 17.82 |
June | 26.18 | 23.21 |
July | 26.73 | 25.63 |
August | 26.40 | 24.08 |
September | 25.64 | 20.49 |
October | 24.43 | 13.71 |
November | 23.42 | 6.96 |
December | 22.88 | 2.07 |
Annual Sum or Average | 24.56 | 13.68 |
Minimum of Months | 22.87 | 2.07 |
Maximum of Months | 26.73 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.28 | 2.60 |
February | 18.42 | 4.29 |
March | 19.40 | 8.77 |
April | 21.10 | 13.91 |
May | 22.14 | 17.82 |
June | 23.81 | 23.21 |
July | 24.65 | 25.63 |
August | 24.27 | 24.08 |
September | 23.41 | 20.49 |
October | 21.66 | 13.71 |
November | 19.68 | 6.96 |
December | 18.47 | 2.07 |
Annual Sum or Average | 21.29 | 13.68 |
Minimum of Months | 18.28 | 2.07 |
Maximum of Months | 24.65 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTLOUNGEFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.32 | 2.60 |
February | 21.50 | 4.29 |
March | 22.00 | 8.77 |
April | 22.75 | 13.91 |
May | 23.22 | 17.82 |
June | 23.61 | 23.21 |
July | 23.85 | 25.63 |
August | 23.81 | 24.08 |
September | 23.55 | 20.49 |
October | 22.71 | 13.71 |
November | 21.69 | 6.96 |
December | 21.21 | 2.07 |
Annual Sum or Average | 22.61 | 13.68 |
Minimum of Months | 21.21 | 2.07 |
Maximum of Months | 23.85 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: RESTROOMFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.32 | 2.60 |
February | 22.45 | 4.29 |
March | 22.78 | 8.77 |
April | 23.21 | 13.91 |
May | 23.44 | 17.82 |
June | 23.64 | 23.21 |
July | 23.72 | 25.63 |
August | 23.70 | 24.08 |
September | 23.61 | 20.49 |
October | 23.26 | 13.71 |
November | 22.75 | 6.96 |
December | 22.34 | 2.07 |
Annual Sum or Average | 23.11 | 13.68 |
Minimum of Months | 22.32 | 2.07 |
Maximum of Months | 23.72 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: MEETINGROOMFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.30 | 2.60 |
February | 22.53 | 4.29 |
March | 23.14 | 8.77 |
April | 23.57 | 13.91 |
May | 23.74 | 17.82 |
June | 23.85 | 23.21 |
July | 23.89 | 25.63 |
August | 23.88 | 24.08 |
September | 23.84 | 20.49 |
October | 23.54 | 13.71 |
November | 22.97 | 6.96 |
December | 22.19 | 2.07 |
Annual Sum or Average | 23.29 | 13.68 |
Minimum of Months | 22.19 | 2.07 |
Maximum of Months | 23.89 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: MECHANICALROOMFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 24.80 | 2.60 |
February | 25.00 | 4.29 |
March | 25.50 | 8.77 |
April | 26.11 | 13.91 |
May | 26.46 | 17.82 |
June | 26.91 | 23.21 |
July | 27.09 | 25.63 |
August | 27.02 | 24.08 |
September | 26.76 | 20.49 |
October | 26.17 | 13.71 |
November | 25.42 | 6.96 |
December | 24.78 | 2.07 |
Annual Sum or Average | 26.01 | 13.68 |
Minimum of Months | 24.78 | 2.07 |
Maximum of Months | 27.09 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM101
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.30 | 2.60 |
February | 20.67 | 4.29 |
March | 21.56 | 8.77 |
April | 22.49 | 13.91 |
May | 22.94 | 17.82 |
June | 23.23 | 23.21 |
July | 23.33 | 25.63 |
August | 23.32 | 24.08 |
September | 23.22 | 20.49 |
October | 22.47 | 13.71 |
November | 21.32 | 6.96 |
December | 20.24 | 2.07 |
Annual Sum or Average | 22.10 | 13.68 |
Minimum of Months | 20.24 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM102
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.95 | 2.60 |
February | 20.32 | 4.29 |
March | 21.20 | 8.77 |
April | 22.22 | 13.91 |
May | 22.73 | 17.82 |
June | 23.14 | 23.21 |
July | 23.31 | 25.63 |
August | 23.28 | 24.08 |
September | 23.09 | 20.49 |
October | 22.19 | 13.71 |
November | 20.93 | 6.96 |
December | 19.88 | 2.07 |
Annual Sum or Average | 21.86 | 13.68 |
Minimum of Months | 19.88 | 2.07 |
Maximum of Months | 23.31 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM103
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.08 | 2.60 |
February | 21.16 | 4.29 |
March | 21.40 | 8.77 |
April | 21.60 | 13.91 |
May | 21.70 | 17.82 |
June | 21.75 | 23.21 |
July | 21.75 | 25.63 |
August | 21.75 | 24.08 |
September | 21.75 | 20.49 |
October | 21.60 | 13.71 |
November | 21.36 | 6.96 |
December | 21.03 | 2.07 |
Annual Sum or Average | 21.50 | 13.68 |
Minimum of Months | 21.03 | 2.07 |
Maximum of Months | 21.75 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM104
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.34 | 2.60 |
February | 21.41 | 4.29 |
March | 21.63 | 8.77 |
April | 21.73 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.70 | 13.71 |
November | 21.57 | 6.96 |
December | 21.29 | 2.07 |
Annual Sum or Average | 21.62 | 13.68 |
Minimum of Months | 21.29 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM105
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.64 | 2.60 |
February | 21.67 | 4.29 |
March | 21.74 | 8.77 |
April | 21.75 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.74 | 13.71 |
November | 21.73 | 6.96 |
December | 21.63 | 2.07 |
Annual Sum or Average | 21.72 | 13.68 |
Minimum of Months | 21.63 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: EMPLOYEELOUNGEFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.58 | 2.60 |
February | 22.61 | 4.29 |
March | 22.74 | 8.77 |
April | 22.79 | 13.91 |
May | 22.73 | 17.82 |
June | 22.43 | 23.21 |
July | 22.29 | 25.63 |
August | 22.38 | 24.08 |
September | 22.62 | 20.49 |
October | 22.81 | 13.71 |
November | 22.79 | 6.96 |
December | 22.62 | 2.07 |
Annual Sum or Average | 22.62 | 13.68 |
Minimum of Months | 22.29 | 2.07 |
Maximum of Months | 22.81 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: LAUNDRYROOMFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 51.26 | 2.60 |
February | 51.38 | 4.29 |
March | 51.84 | 8.77 |
April | 52.49 | 13.91 |
May | 52.86 | 17.82 |
June | 53.48 | 23.21 |
July | 53.74 | 25.63 |
August | 53.62 | 24.08 |
September | 53.22 | 20.49 |
October | 52.55 | 13.71 |
November | 51.79 | 6.96 |
December | 51.30 | 2.07 |
Annual Sum or Average | 52.47 | 13.68 |
Minimum of Months | 51.26 | 2.07 |
Maximum of Months | 53.74 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 69.43 | 2.60 |
February | 69.46 | 4.29 |
March | 69.84 | 8.77 |
April | 70.57 | 13.91 |
May | 71.03 | 17.82 |
June | 71.88 | 23.21 |
July | 72.28 | 25.63 |
August | 72.11 | 24.08 |
September | 71.71 | 20.49 |
October | 70.88 | 13.71 |
November | 69.98 | 6.96 |
December | 69.54 | 2.07 |
Annual Sum or Average | 70.73 | 13.68 |
Minimum of Months | 69.43 | 2.07 |
Maximum of Months | 72.28 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: EXERCISECENTERFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.10 | 2.60 |
February | 23.18 | 4.29 |
March | 23.46 | 8.77 |
April | 23.76 | 13.91 |
May | 23.86 | 17.82 |
June | 23.89 | 23.21 |
July | 23.89 | 25.63 |
August | 23.89 | 24.08 |
September | 23.89 | 20.49 |
October | 23.75 | 13.71 |
November | 23.44 | 6.96 |
December | 23.13 | 2.07 |
Annual Sum or Average | 23.60 | 13.68 |
Minimum of Months | 23.10 | 2.07 |
Maximum of Months | 23.89 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTOFFICEFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.74 | 2.60 |
February | 22.94 | 4.29 |
March | 23.45 | 8.77 |
April | 23.79 | 13.91 |
May | 23.87 | 17.82 |
June | 23.89 | 23.21 |
July | 23.89 | 25.63 |
August | 23.89 | 24.08 |
September | 23.89 | 20.49 |
October | 23.77 | 13.71 |
November | 23.41 | 6.96 |
December | 22.79 | 2.07 |
Annual Sum or Average | 23.53 | 13.68 |
Minimum of Months | 22.74 | 2.07 |
Maximum of Months | 23.89 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.19 | 2.60 |
February | 18.33 | 4.29 |
March | 19.69 | 8.77 |
April | 21.80 | 13.91 |
May | 23.19 | 17.82 |
June | 25.26 | 23.21 |
July | 26.18 | 25.63 |
August | 25.57 | 24.08 |
September | 24.35 | 20.49 |
October | 22.11 | 13.71 |
November | 19.73 | 6.96 |
December | 18.31 | 2.07 |
Annual Sum or Average | 21.91 | 13.68 |
Minimum of Months | 18.19 | 2.07 |
Maximum of Months | 26.18 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR1
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.82 | 2.60 |
February | 20.98 | 4.29 |
March | 21.91 | 8.77 |
April | 23.17 | 13.91 |
May | 23.94 | 17.82 |
June | 25.06 | 23.21 |
July | 25.56 | 25.63 |
August | 25.25 | 24.08 |
September | 24.56 | 20.49 |
October | 23.31 | 13.71 |
November | 21.87 | 6.96 |
December | 20.87 | 2.07 |
Annual Sum or Average | 23.12 | 13.68 |
Minimum of Months | 20.82 | 2.07 |
Maximum of Months | 25.56 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR2
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.93 | 2.60 |
February | 19.02 | 4.29 |
March | 20.30 | 8.77 |
April | 22.38 | 13.91 |
May | 23.55 | 17.82 |
June | 25.52 | 23.21 |
July | 26.52 | 25.63 |
August | 26.03 | 24.08 |
September | 25.02 | 20.49 |
October | 22.96 | 13.71 |
November | 20.60 | 6.96 |
December | 19.12 | 2.07 |
Annual Sum or Average | 22.52 | 13.68 |
Minimum of Months | 18.93 | 2.07 |
Maximum of Months | 26.52 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR2
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.36 | 2.60 |
February | 22.59 | 4.29 |
March | 23.31 | 8.77 |
April | 23.77 | 13.91 |
May | 23.85 | 17.82 |
June | 23.95 | 23.21 |
July | 23.98 | 25.63 |
August | 23.93 | 24.08 |
September | 23.89 | 20.49 |
October | 23.69 | 13.71 |
November | 23.17 | 6.96 |
December | 22.28 | 2.07 |
Annual Sum or Average | 23.40 | 13.68 |
Minimum of Months | 22.28 | 2.07 |
Maximum of Months | 23.98 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR2
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.43 | 2.60 |
February | 17.61 | 4.29 |
March | 18.95 | 8.77 |
April | 21.14 | 13.91 |
May | 22.42 | 17.82 |
June | 24.45 | 23.21 |
July | 25.45 | 25.63 |
August | 24.97 | 24.08 |
September | 23.94 | 20.49 |
October | 21.73 | 13.71 |
November | 19.18 | 6.96 |
December | 17.59 | 2.07 |
Annual Sum or Average | 21.26 | 13.68 |
Minimum of Months | 17.43 | 2.07 |
Maximum of Months | 25.45 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM201
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.33 | 2.60 |
February | 19.70 | 4.29 |
March | 20.73 | 8.77 |
April | 22.30 | 13.91 |
May | 22.91 | 17.82 |
June | 23.24 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.26 | 20.49 |
October | 22.10 | 13.71 |
November | 20.21 | 6.96 |
December | 19.21 | 2.07 |
Annual Sum or Average | 21.65 | 13.68 |
Minimum of Months | 19.21 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM202_205
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.26 | 2.60 |
February | 21.35 | 4.29 |
March | 21.60 | 8.77 |
April | 21.72 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.68 | 13.71 |
November | 21.51 | 6.96 |
December | 21.17 | 2.07 |
Annual Sum or Average | 21.59 | 13.68 |
Minimum of Months | 21.17 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM206_208
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.33 | 2.60 |
February | 21.41 | 4.29 |
March | 21.64 | 8.77 |
April | 21.73 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.70 | 13.71 |
November | 21.57 | 6.96 |
December | 21.25 | 2.07 |
Annual Sum or Average | 21.62 | 13.68 |
Minimum of Months | 21.25 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM209_212
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.37 | 2.60 |
February | 21.44 | 4.29 |
March | 21.65 | 8.77 |
April | 21.73 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.70 | 13.71 |
November | 21.59 | 6.96 |
December | 21.29 | 2.07 |
Annual Sum or Average | 21.63 | 13.68 |
Minimum of Months | 21.29 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM213
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.07 | 2.60 |
February | 21.15 | 4.29 |
March | 21.44 | 8.77 |
April | 21.65 | 13.91 |
May | 21.72 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.63 | 13.71 |
November | 21.38 | 6.96 |
December | 21.00 | 2.07 |
Annual Sum or Average | 21.51 | 13.68 |
Minimum of Months | 21.00 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM214
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.43 | 2.60 |
February | 21.48 | 4.29 |
March | 21.70 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.72 | 13.71 |
November | 21.65 | 6.96 |
December | 21.37 | 2.07 |
Annual Sum or Average | 21.66 | 13.68 |
Minimum of Months | 21.37 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM215_218
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 23.15 | 2.60 |
February | 23.20 | 4.29 |
March | 23.32 | 8.77 |
April | 23.33 | 13.91 |
May | 23.33 | 17.82 |
June | 23.33 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.33 | 20.49 |
October | 23.32 | 13.71 |
November | 23.31 | 6.96 |
December | 23.16 | 2.07 |
Annual Sum or Average | 23.29 | 13.68 |
Minimum of Months | 23.15 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR2
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 31.10 | 2.60 |
February | 31.21 | 4.29 |
March | 31.84 | 8.77 |
April | 32.67 | 13.91 |
May | 33.09 | 17.82 |
June | 33.79 | 23.21 |
July | 34.12 | 25.63 |
August | 33.94 | 24.08 |
September | 33.55 | 20.49 |
October | 32.76 | 13.71 |
November | 31.79 | 6.96 |
December | 31.09 | 2.07 |
Annual Sum or Average | 32.58 | 13.68 |
Minimum of Months | 31.09 | 2.07 |
Maximum of Months | 34.12 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM219
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.89 | 2.60 |
February | 21.96 | 4.29 |
March | 22.16 | 8.77 |
April | 22.42 | 13.91 |
May | 22.70 | 17.82 |
June | 23.26 | 23.21 |
July | 23.63 | 25.63 |
August | 23.44 | 24.08 |
September | 23.01 | 20.49 |
October | 22.48 | 13.71 |
November | 22.06 | 6.96 |
December | 21.86 | 2.07 |
Annual Sum or Average | 22.58 | 13.68 |
Minimum of Months | 21.86 | 2.07 |
Maximum of Months | 23.63 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM220_223
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.56 | 2.60 |
February | 21.60 | 4.29 |
March | 21.74 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.74 | 13.71 |
November | 21.71 | 6.96 |
December | 21.48 | 2.07 |
Annual Sum or Average | 21.70 | 13.68 |
Minimum of Months | 21.48 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM224
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.39 | 2.60 |
February | 21.46 | 4.29 |
March | 21.70 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.73 | 13.71 |
November | 21.64 | 6.96 |
December | 21.31 | 2.07 |
Annual Sum or Average | 21.65 | 13.68 |
Minimum of Months | 21.31 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR2
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.96 | 2.60 |
February | 20.13 | 4.29 |
March | 21.43 | 8.77 |
April | 23.11 | 13.91 |
May | 24.12 | 17.82 |
June | 25.56 | 23.21 |
July | 26.20 | 25.63 |
August | 25.78 | 24.08 |
September | 24.90 | 20.49 |
October | 23.21 | 13.71 |
November | 21.27 | 6.96 |
December | 19.93 | 2.07 |
Annual Sum or Average | 22.98 | 13.68 |
Minimum of Months | 19.93 | 2.07 |
Maximum of Months | 26.20 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR2
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 17.22 | 2.60 |
February | 17.39 | 4.29 |
March | 19.29 | 8.77 |
April | 22.01 | 13.91 |
May | 23.77 | 17.82 |
June | 26.36 | 23.21 |
July | 27.51 | 25.63 |
August | 26.72 | 24.08 |
September | 25.19 | 20.49 |
October | 22.32 | 13.71 |
November | 19.21 | 6.96 |
December | 17.27 | 2.07 |
Annual Sum or Average | 22.05 | 13.68 |
Minimum of Months | 17.22 | 2.07 |
Maximum of Months | 27.51 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR3
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.12 | 2.60 |
February | 18.27 | 4.29 |
March | 19.78 | 8.77 |
April | 22.18 | 13.91 |
May | 23.54 | 17.82 |
June | 25.72 | 23.21 |
July | 26.81 | 25.63 |
August | 26.27 | 24.08 |
September | 25.13 | 20.49 |
October | 22.73 | 13.71 |
November | 19.98 | 6.96 |
December | 18.26 | 2.07 |
Annual Sum or Average | 22.25 | 13.68 |
Minimum of Months | 18.12 | 2.07 |
Maximum of Months | 26.81 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR3
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.34 | 2.60 |
February | 21.57 | 4.29 |
March | 22.25 | 8.77 |
April | 23.30 | 13.91 |
May | 23.65 | 17.82 |
June | 23.85 | 23.21 |
July | 23.89 | 25.63 |
August | 23.89 | 24.08 |
September | 23.86 | 20.49 |
October | 23.19 | 13.71 |
November | 21.94 | 6.96 |
December | 21.24 | 2.07 |
Annual Sum or Average | 22.84 | 13.68 |
Minimum of Months | 21.24 | 2.07 |
Maximum of Months | 23.89 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR3
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 16.25 | 2.60 |
February | 16.52 | 4.29 |
March | 18.16 | 8.77 |
April | 20.82 | 13.91 |
May | 22.38 | 17.82 |
June | 24.70 | 23.21 |
July | 25.81 | 25.63 |
August | 25.28 | 24.08 |
September | 24.07 | 20.49 |
October | 21.38 | 13.71 |
November | 18.23 | 6.96 |
December | 16.36 | 2.07 |
Annual Sum or Average | 20.85 | 13.68 |
Minimum of Months | 16.25 | 2.07 |
Maximum of Months | 25.81 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM301
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.02 | 2.60 |
February | 19.29 | 4.29 |
March | 20.05 | 8.77 |
April | 21.87 | 13.91 |
May | 22.69 | 17.82 |
June | 23.18 | 23.21 |
July | 23.33 | 25.63 |
August | 23.32 | 24.08 |
September | 23.17 | 20.49 |
October | 21.67 | 13.71 |
November | 19.54 | 6.96 |
December | 18.95 | 2.07 |
Annual Sum or Average | 21.35 | 13.68 |
Minimum of Months | 18.95 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM302_305
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.22 | 2.60 |
February | 19.61 | 4.29 |
March | 20.65 | 8.77 |
April | 22.29 | 13.91 |
May | 22.92 | 17.82 |
June | 23.25 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.26 | 20.49 |
October | 22.02 | 13.71 |
November | 20.01 | 6.96 |
December | 19.10 | 2.07 |
Annual Sum or Average | 21.59 | 13.68 |
Minimum of Months | 19.10 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM306_308
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.36 | 2.60 |
February | 19.79 | 4.29 |
March | 20.88 | 8.77 |
April | 22.38 | 13.91 |
May | 22.94 | 17.82 |
June | 23.25 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.26 | 20.49 |
October | 22.11 | 13.71 |
November | 20.25 | 6.96 |
December | 19.22 | 2.07 |
Annual Sum or Average | 21.68 | 13.68 |
Minimum of Months | 19.22 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM309_312
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.27 | 2.60 |
February | 21.35 | 4.29 |
March | 21.59 | 8.77 |
April | 21.70 | 13.91 |
May | 21.74 | 17.82 |
June | 21.75 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.67 | 13.71 |
November | 21.51 | 6.96 |
December | 21.17 | 2.07 |
Annual Sum or Average | 21.59 | 13.68 |
Minimum of Months | 21.17 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM313
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.25 | 2.60 |
February | 19.60 | 4.29 |
March | 20.53 | 8.77 |
April | 22.12 | 13.91 |
May | 22.79 | 17.82 |
June | 23.22 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.24 | 20.49 |
October | 22.03 | 13.71 |
November | 20.13 | 6.96 |
December | 19.15 | 2.07 |
Annual Sum or Average | 21.57 | 13.68 |
Minimum of Months | 19.15 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM314
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.22 | 2.60 |
February | 21.30 | 4.29 |
March | 21.60 | 8.77 |
April | 21.74 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.69 | 13.71 |
November | 21.50 | 6.96 |
December | 21.14 | 2.07 |
Annual Sum or Average | 21.58 | 13.68 |
Minimum of Months | 21.14 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM315_318
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.57 | 2.60 |
February | 21.61 | 4.29 |
March | 21.74 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.74 | 13.71 |
November | 21.71 | 6.96 |
December | 21.50 | 2.07 |
Annual Sum or Average | 21.70 | 13.68 |
Minimum of Months | 21.50 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR3
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 22.76 | 2.60 |
February | 22.97 | 4.29 |
March | 23.87 | 8.77 |
April | 25.06 | 13.91 |
May | 25.61 | 17.82 |
June | 26.34 | 23.21 |
July | 26.66 | 25.63 |
August | 26.47 | 24.08 |
September | 26.04 | 20.49 |
October | 25.02 | 13.71 |
November | 23.67 | 6.96 |
December | 22.70 | 2.07 |
Annual Sum or Average | 24.77 | 13.68 |
Minimum of Months | 22.70 | 2.07 |
Maximum of Months | 26.66 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM319
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.53 | 2.60 |
February | 21.86 | 4.29 |
March | 22.78 | 8.77 |
April | 23.23 | 13.91 |
May | 23.31 | 17.82 |
June | 23.33 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.33 | 20.49 |
October | 23.11 | 13.71 |
November | 22.52 | 6.96 |
December | 21.38 | 2.07 |
Annual Sum or Average | 22.76 | 13.68 |
Minimum of Months | 21.38 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM320_323
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.44 | 2.60 |
February | 21.50 | 4.29 |
March | 21.71 | 8.77 |
April | 21.75 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.72 | 13.71 |
November | 21.64 | 6.96 |
December | 21.34 | 2.07 |
Annual Sum or Average | 21.66 | 13.68 |
Minimum of Months | 21.34 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM324
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.75 | 2.60 |
February | 20.12 | 4.29 |
March | 21.44 | 8.77 |
April | 22.69 | 13.91 |
May | 23.08 | 17.82 |
June | 23.29 | 23.21 |
July | 23.33 | 25.63 |
August | 23.33 | 24.08 |
September | 23.29 | 20.49 |
October | 22.47 | 13.71 |
November | 20.89 | 6.96 |
December | 19.52 | 2.07 |
Annual Sum or Average | 21.94 | 13.68 |
Minimum of Months | 19.52 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR3
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.81 | 2.60 |
February | 19.08 | 4.29 |
March | 20.73 | 8.77 |
April | 22.87 | 13.91 |
May | 24.11 | 17.82 |
June | 25.80 | 23.21 |
July | 26.54 | 25.63 |
August | 26.05 | 24.08 |
September | 25.01 | 20.49 |
October | 22.89 | 13.71 |
November | 20.40 | 6.96 |
December | 18.71 | 2.07 |
Annual Sum or Average | 22.60 | 13.68 |
Minimum of Months | 18.71 | 2.07 |
Maximum of Months | 26.54 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR3
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 16.22 | 2.60 |
February | 16.47 | 4.29 |
March | 18.67 | 8.77 |
April | 21.78 | 13.91 |
May | 23.77 | 17.82 |
June | 26.65 | 23.21 |
July | 27.91 | 25.63 |
August | 27.04 | 24.08 |
September | 25.33 | 20.49 |
October | 22.04 | 13.71 |
November | 18.45 | 6.96 |
December | 16.21 | 2.07 |
Annual Sum or Average | 21.74 | 13.68 |
Minimum of Months | 16.21 | 2.07 |
Maximum of Months | 27.91 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTAIRSFLR4
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 16.79 | 2.60 |
February | 17.17 | 4.29 |
March | 18.97 | 8.77 |
April | 21.86 | 13.91 |
May | 23.50 | 17.82 |
June | 26.02 | 23.21 |
July | 27.24 | 25.63 |
August | 26.64 | 24.08 |
September | 25.21 | 20.49 |
October | 22.26 | 13.71 |
November | 18.92 | 6.96 |
December | 16.89 | 2.07 |
Annual Sum or Average | 21.81 | 13.68 |
Minimum of Months | 16.79 | 2.07 |
Maximum of Months | 27.24 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: CORRIDORFLR4
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.35 | 2.60 |
February | 21.52 | 4.29 |
March | 21.97 | 8.77 |
April | 22.79 | 13.91 |
May | 23.25 | 17.82 |
June | 23.82 | 23.21 |
July | 24.11 | 25.63 |
August | 23.98 | 24.08 |
September | 23.60 | 20.49 |
October | 22.69 | 13.71 |
November | 21.65 | 6.96 |
December | 21.22 | 2.07 |
Annual Sum or Average | 22.67 | 13.68 |
Minimum of Months | 21.22 | 2.07 |
Maximum of Months | 24.11 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: REARSTORAGEFLR4
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 15.32 | 2.60 |
February | 15.77 | 4.29 |
March | 17.57 | 8.77 |
April | 20.55 | 13.91 |
May | 22.33 | 17.82 |
June | 24.96 | 23.21 |
July | 26.20 | 25.63 |
August | 25.60 | 24.08 |
September | 24.11 | 20.49 |
October | 20.97 | 13.71 |
November | 17.44 | 6.96 |
December | 15.40 | 2.07 |
Annual Sum or Average | 20.54 | 13.68 |
Minimum of Months | 15.32 | 2.07 |
Maximum of Months | 26.20 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM401
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.78 | 2.60 |
February | 20.93 | 4.29 |
March | 21.26 | 8.77 |
April | 21.59 | 13.91 |
May | 21.70 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.50 | 13.71 |
November | 21.11 | 6.96 |
December | 20.67 | 2.07 |
Annual Sum or Average | 21.38 | 13.68 |
Minimum of Months | 20.67 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM402_405
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.24 | 2.60 |
February | 19.55 | 4.29 |
March | 20.26 | 8.77 |
April | 21.70 | 13.91 |
May | 22.48 | 17.82 |
June | 23.05 | 23.21 |
July | 23.32 | 25.63 |
August | 23.28 | 24.08 |
September | 22.97 | 20.49 |
October | 21.48 | 13.71 |
November | 19.69 | 6.96 |
December | 19.08 | 2.07 |
Annual Sum or Average | 21.35 | 13.68 |
Minimum of Months | 19.08 | 2.07 |
Maximum of Months | 23.32 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM406_408
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.32 | 2.60 |
February | 19.65 | 4.29 |
March | 20.36 | 8.77 |
April | 21.75 | 13.91 |
May | 22.49 | 17.82 |
June | 23.05 | 23.21 |
July | 23.31 | 25.63 |
August | 23.28 | 24.08 |
September | 22.96 | 20.49 |
October | 21.52 | 13.71 |
November | 19.81 | 6.96 |
December | 19.15 | 2.07 |
Annual Sum or Average | 21.40 | 13.68 |
Minimum of Months | 19.15 | 2.07 |
Maximum of Months | 23.31 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM409_412
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.26 | 2.60 |
February | 21.38 | 4.29 |
March | 21.61 | 8.77 |
April | 21.72 | 13.91 |
May | 21.75 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.75 | 20.49 |
October | 21.66 | 13.71 |
November | 21.54 | 6.96 |
December | 21.16 | 2.07 |
Annual Sum or Average | 21.59 | 13.68 |
Minimum of Months | 21.16 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM413
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.27 | 2.60 |
February | 19.57 | 4.29 |
March | 20.25 | 8.77 |
April | 21.66 | 13.91 |
May | 22.43 | 17.82 |
June | 23.05 | 23.21 |
July | 23.32 | 25.63 |
August | 23.28 | 24.08 |
September | 22.98 | 20.49 |
October | 21.57 | 13.71 |
November | 19.82 | 6.96 |
December | 19.12 | 2.07 |
Annual Sum or Average | 21.37 | 13.68 |
Minimum of Months | 19.12 | 2.07 |
Maximum of Months | 23.32 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM414
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 19.52 | 2.60 |
February | 19.86 | 4.29 |
March | 20.79 | 8.77 |
April | 22.12 | 13.91 |
May | 22.71 | 17.82 |
June | 23.15 | 23.21 |
July | 23.33 | 25.63 |
August | 23.30 | 24.08 |
September | 23.10 | 20.49 |
October | 21.97 | 13.71 |
November | 20.30 | 6.96 |
December | 19.31 | 2.07 |
Annual Sum or Average | 21.63 | 13.68 |
Minimum of Months | 19.31 | 2.07 |
Maximum of Months | 23.33 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM415_418
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.49 | 2.60 |
February | 21.57 | 4.29 |
March | 21.72 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.72 | 13.71 |
November | 21.69 | 6.96 |
December | 21.41 | 2.07 |
Annual Sum or Average | 21.68 | 13.68 |
Minimum of Months | 21.41 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: ELEVATORCOREFLR4
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 20.47 | 2.60 |
February | 20.82 | 4.29 |
March | 21.82 | 8.77 |
April | 23.23 | 13.91 |
May | 23.96 | 17.82 |
June | 24.98 | 23.21 |
July | 25.44 | 25.63 |
August | 25.17 | 24.08 |
September | 24.44 | 20.49 |
October | 23.03 | 13.71 |
November | 21.43 | 6.96 |
December | 20.36 | 2.07 |
Annual Sum or Average | 22.94 | 13.68 |
Minimum of Months | 20.36 | 2.07 |
Maximum of Months | 25.44 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM419
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.42 | 2.60 |
February | 21.52 | 4.29 |
March | 21.71 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.71 | 13.71 |
November | 21.66 | 6.96 |
December | 21.34 | 2.07 |
Annual Sum or Average | 21.66 | 13.68 |
Minimum of Months | 21.34 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM420_423
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.46 | 2.60 |
February | 21.55 | 4.29 |
March | 21.71 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.72 | 13.71 |
November | 21.68 | 6.96 |
December | 21.37 | 2.07 |
Annual Sum or Average | 21.67 | 13.68 |
Minimum of Months | 21.37 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: GUESTROOM424
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 21.20 | 2.60 |
February | 21.33 | 4.29 |
March | 21.65 | 8.77 |
April | 21.75 | 13.91 |
May | 21.76 | 17.82 |
June | 21.76 | 23.21 |
July | 21.76 | 25.63 |
August | 21.76 | 24.08 |
September | 21.76 | 20.49 |
October | 21.69 | 13.71 |
November | 21.54 | 6.96 |
December | 21.07 | 2.07 |
Annual Sum or Average | 21.59 | 13.68 |
Minimum of Months | 21.07 | 2.07 |
Maximum of Months | 21.76 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTORAGEFLR4
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 18.26 | 2.60 |
February | 18.68 | 4.29 |
March | 20.39 | 8.77 |
April | 22.69 | 13.91 |
May | 24.05 | 17.82 |
June | 25.94 | 23.21 |
July | 26.77 | 25.63 |
August | 26.24 | 24.08 |
September | 24.97 | 20.49 |
October | 22.56 | 13.71 |
November | 19.90 | 6.96 |
December | 18.12 | 2.07 |
Annual Sum or Average | 22.40 | 13.68 |
Minimum of Months | 18.12 | 2.07 |
Maximum of Months | 26.77 | 25.63 |
Report: MONTHLY INDOOR TEMP
For: FRONTSTAIRSFLR4
Timestamp: 2015-09-14 08:44:12
ZONE MEAN AIR TEMPERATURE [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 15.35 | 2.60 |
February | 15.79 | 4.29 |
March | 18.16 | 8.77 |
April | 21.55 | 13.91 |
May | 23.71 | 17.82 |
June | 26.85 | 23.21 |
July | 28.21 | 25.63 |
August | 27.30 | 24.08 |
September | 25.32 | 20.49 |
October | 21.64 | 13.71 |
November | 17.74 | 6.96 |
December | 15.30 | 2.07 |
Annual Sum or Average | 21.44 | 13.68 |
Minimum of Months | 15.30 | 2.07 |
Maximum of Months | 28.21 | 25.63 |
Report: PEAK ELECTRICAL DEMAND
For: Meter
Timestamp: 2015-09-14 08:44:12
ELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [Invalid/Undefined] | EXTERIOREQUIPMENT:ELECTRICITY [Invalid/Undefined] | HUMIDIFICATION:ELECTRICITY [Invalid/Undefined] | HEATRECOVERY:ELECTRICITY [Invalid/Undefined] | WATERSYSTEMS:ELECTRICITY [Invalid/Undefined] | REFRIGERATION:ELECTRICITY [Invalid/Undefined] | GENERATORS:ELECTRICITY [Invalid/Undefined] | ELECTRICITYPRODUCED:FACILITY [Invalid/Undefined] | |
January | 0.160756E+12 | 118735.778 | 17-JAN-07:15 | 20847.837 | 39740.848 | 9722.796 | 43865.521 | 362.663 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
February | 0.142819E+12 | 116361.230 | 05-FEB-07:15 | 20847.837 | 39740.848 | 9722.796 | 45636.076 | 405.559 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
March | 0.153208E+12 | 102352.475 | 05-MAR-07:15 | 20847.837 | 39740.848 | 9722.796 | 29416.827 | 2616.054 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
April | 0.154053E+12 | 95940.584 | 28-APR-07:00 | 25182.171 | 43578.554 | 10357.313 | 0.000 | 16814.433 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
May | 0.167025E+12 | 100117.915 | 19-MAY-07:00 | 25182.171 | 43578.554 | 10357.313 | 0.000 | 20991.764 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
June | 0.177623E+12 | 106243.654 | 24-JUN-07:00 | 25182.171 | 43578.554 | 10357.313 | 0.000 | 27117.504 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
July | 0.194787E+12 | 110351.718 | 21-JUL-07:00 | 25182.171 | 43578.554 | 10357.313 | 0.000 | 31225.567 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
August | 0.189479E+12 | 106417.212 | 12-AUG-07:00 | 25182.171 | 43578.554 | 10357.313 | 0.000 | 27291.062 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
September | 0.170939E+12 | 103729.070 | 03-SEP-07:00 | 25182.171 | 43578.554 | 10357.313 | 0.000 | 24602.920 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
October | 0.161302E+12 | 105274.500 | 26-OCT-06:15 | 20847.837 | 39740.848 | 9722.796 | 29249.312 | 1517.595 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
November | 0.147838E+12 | 106145.801 | 27-NOV-07:15 | 20847.837 | 39740.848 | 9722.796 | 34680.157 | 1146.050 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
December | 0.160610E+12 | 116808.675 | 22-DEC-07:15 | 17938.631 | 34285.948 | 9722.796 | 50438.054 | 227.134 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Annual Sum or Average | 0.198044E+13 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
Minimum of Months | 0.142819E+12 | 95940.584 | 17938.631 | 34285.948 | 9722.796 | 0.000 | 227.134 | 0.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |
Maximum of Months | 0.194787E+12 | 118735.778 | 25182.171 | 43578.554 | 10357.313 | 50438.054 | 31225.567 | 4188.000 | 8.113 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: PEAK GAS DEMAND
For: Meter
Timestamp: 2015-09-14 08:44:12
GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | GAS:HVAC {AT MAX/MIN} [W] | INTERIOREQUIPMENT:GAS {AT MAX/MIN} [W] | MISCPLUGGAS:INTERIOREQUIPMENT:GAS [Invalid/Undefined] | GAS:PLANT {AT MAX/MIN} [W] | WATERSYSTEMS:GAS {AT MAX/MIN} [W] | WATER HEATER:WATERSYSTEMS:GAS {AT MAX/MIN} [W] | HEATING:GAS {AT MAX/MIN} [W] | |
January | 0.981898E+11 | 107473.161 | 20-JAN-09:15 | 632.592 | 40096.028 | 0.000 | 66744.541 | 66744.541 | 66744.541 | 632.592 |
February | 0.880611E+11 | 104184.975 | 18-FEB-09:15 | 0.000 | 40096.028 | 0.000 | 64088.947 | 64088.947 | 64088.947 | 0.000 |
March | 0.932823E+11 | 101249.190 | 18-MAR-08:15 | 0.000 | 40096.028 | 0.000 | 61153.162 | 61153.162 | 61153.162 | 0.000 |
April | 0.861539E+11 | 91727.249 | 01-APR-08:15 | 0.000 | 40096.028 | 0.000 | 51631.221 | 51631.221 | 51631.221 | 0.000 |
May | 0.850865E+11 | 87525.923 | 12-MAY-08:15 | 0.000 | 40096.028 | 0.000 | 47429.895 | 47429.895 | 47429.895 | 0.000 |
June | 0.789493E+11 | 84057.823 | 02-JUN-08:15 | 0.000 | 40096.028 | 0.000 | 43961.795 | 43961.795 | 43961.795 | 0.000 |
July | 0.792973E+11 | 83201.363 | 07-JUL-08:15 | 0.000 | 40096.028 | 0.000 | 43105.335 | 43105.335 | 43105.335 | 0.000 |
August | 0.787879E+11 | 82758.706 | 18-AUG-08:15 | 0.000 | 40096.028 | 0.000 | 42662.678 | 42662.678 | 42662.678 | 0.000 |
September | 0.775629E+11 | 83373.690 | 30-SEP-08:15 | 0.000 | 40096.028 | 0.000 | 43277.662 | 43277.662 | 43277.662 | 0.000 |
October | 0.836527E+11 | 85493.440 | 21-OCT-08:15 | 0.000 | 40096.028 | 0.000 | 45397.412 | 45397.412 | 45397.412 | 0.000 |
November | 0.860205E+11 | 91839.586 | 22-NOV-09:15 | 0.000 | 40096.028 | 0.000 | 51743.557 | 51743.557 | 51743.557 | 0.000 |
December | 0.958339E+11 | 105620.360 | 29-DEC-09:15 | 0.000 | 40096.028 | 0.000 | 65524.332 | 65524.332 | 65524.332 | 0.000 |
Annual Sum or Average | 0.103088E+13 | 0.000 | ||||||||
Minimum of Months | 0.775629E+11 | 82758.706 | 0.000 | 40096.028 | 0.000 | 42662.678 | 42662.678 | 42662.678 | 0.000 | |
Maximum of Months | 0.981898E+11 | 107473.161 | 632.592 | 40096.028 | 0.000 | 66744.541 | 66744.541 | 66744.541 | 632.592 |