Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:21
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750
Simulation Timestamp: 2020-06-03 19:21:27
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1520.13 | 727.22 | 727.22 |
Net Site Energy | 1520.13 | 727.22 | 727.22 |
Total Source Energy | 3591.36 | 1718.09 | 1718.09 |
Net Source Energy | 3591.36 | 1718.09 | 1718.09 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 587.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 49.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 450.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 59.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 179.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 65.79 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 933.05 | 587.08 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 587.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 49.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 450.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 59.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 179.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 65.79 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 244.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 140.91 | 280.86 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 446.37 | 280.86 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 244.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 140.91 | 280.86 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 446.37 | 280.86 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 933.049 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 933.049 | 100.00 |
Total On-Site and Utility Electric Sources | 933.049 | 100.00 |
Total Electricity End Uses | 933.049 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 2.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2287.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:21 |
RunPeriod | RUNPERIOD 1 |
Weather File | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Latitude [deg] | 47.47 |
Longitude [deg] | -111.4 |
Elevation [m] | 1117.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 16.9114 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 19.7854 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.1708 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.1708 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.1708 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 11.2173 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 14.6187 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 14.6187 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 17-JUL-16:40 | 08-JAN-17:00 | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 302456.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 35536.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 29013.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 11513.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 7559.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 91682.11 | 302456.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 302456.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 35536.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 29013.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 11513.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 7559.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 636.40 | 0.00 | 0.00 | 0.00 |
Cooling | 157.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1427.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 188.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 405.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 567.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 208.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2954.97 | 636.40 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 304.45 | 0.00 | 0.00 | 0.00 |
Cooling | 75.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 683.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 90.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 271.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 99.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1413.64 | 304.45 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 304.45 | 0.00 | 0.00 | 0.00 |
Cooling | 75.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 683.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 90.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 271.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 99.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1413.64 | 304.45 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 1.87 |
SMSTORE1 DIRECT AIR | 1.05 |
SMSTORE2 DIRECT AIR | 1.04 |
SMSTORE3 DIRECT AIR | 1.06 |
SMSTORE4 DIRECT AIR | 1.02 |
LGSTORE2 DIRECT AIR | 1.80 |
SMSTORE5 DIRECT AIR | 0.896637 |
SMSTORE6 DIRECT AIR | 0.915526 |
SMSTORE7 DIRECT AIR | 0.903463 |
SMSTORE8 DIRECT AIR | 1.01 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 1.87 | 1.87 | 1.87 | 1.87 | 1.87 | 1.87 | 1.00 | 1.00 | 1.87 |
PSZ-AC_2:2 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.00 | 1.00 | 1.05 |
PSZ-AC_3:3 | 1.04 | 1.04 | 1.04 | 1.04 | 1.06 | 1.06 | 1.00 | 0.980405 | 1.06 |
PSZ-AC_4:4 | 1.06 | 1.06 | 1.06 | 1.06 | 1.06 | 1.06 | 1.00 | 1.00 | 1.06 |
PSZ-AC_5:5 | 1.02 | 1.02 | 1.02 | 1.02 | 1.05 | 1.05 | 1.00 | 0.977263 | 1.05 |
PSZ-AC_6:6 | 1.80 | 1.80 | 1.80 | 1.80 | 1.80 | 1.80 | 1.00 | 1.00 | 1.80 |
PSZ-AC_7:7 | 0.896637 | 0.896637 | 0.896637 | 0.896637 | 0.925166 | 0.925166 | 1.00 | 0.969163 | 0.925166 |
PSZ-AC_8:8 | 0.915526 | 0.915526 | 0.915526 | 0.915526 | 0.915526 | 0.915526 | 1.00 | 1.00 | 0.915526 |
PSZ-AC_9:9 | 0.903463 | 0.903463 | 0.903463 | 0.903463 | 0.903463 | 0.903463 | 1.00 | 1.00 | 0.903463 |
PSZ-AC_10:10 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.00 | 1.00 | 1.01 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 1.87 | 0.411453 |
PSZ-AC_2:2_OA_CONTROLLER | 1.05 | 0.205727 |
PSZ-AC_3:3_OA_CONTROLLER | 1.06 | 0.205727 |
PSZ-AC_4:4_OA_CONTROLLER | 1.06 | 0.205727 |
PSZ-AC_5:5_OA_CONTROLLER | 1.05 | 0.205727 |
PSZ-AC_6:6_OA_CONTROLLER | 1.80 | 0.411453 |
PSZ-AC_7:7_OA_CONTROLLER | 0.925166 | 0.205727 |
PSZ-AC_8:8_OA_CONTROLLER | 0.915526 | 0.205727 |
PSZ-AC_9:9_OA_CONTROLLER | 0.903463 | 0.205727 |
PSZ-AC_10:10_OA_CONTROLLER | 1.01 | 0.205727 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 1.87 | 1.87 | 1.87 | 1.23 | 31452.19 | 58604.93 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 1.05 | 1.05 | 1.05 | 1.05 | 17378.15 | 31528.53 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.06 | 1.06 | 1.06 | 1.06 | 17520.91 | 31306.64 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 1.06 | 1.06 | 1.06 | 1.06 | 17588.94 | 31812.13 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 1.05 | 1.05 | 1.05 | 1.05 | 17392.07 | 31070.23 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 1.80 | 1.80 | 1.80 | 1.19 | 30378.79 | 57156.20 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 0.925166 | 0.925166 | 0.925166 | 0.925166 | 15581.47 | 28531.97 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 0.915526 | 0.915526 | 0.915526 | 0.915526 | 15438.56 | 28909.66 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 0.903463 | 0.903463 | 0.903463 | 0.903463 | 15259.69 | 28668.46 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 1.01 | 1.01 | 1.01 | 1.01 | 16988.69 | 30713.35 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 1.87 | 0.935180 | 1.25 | 30961.10 | 31452.19 | 15726.09 | 15726.09 | 0.792915 | 0.792910 | 0.792910 | 0.792910 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 1.05 | 0.523250 | 0.697667 | 17323.29 | 17378.15 | 8689.08 | 8689.08 | 0.797495 | 0.797500 | 0.797500 | 0.797500 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 1.06 | 0.528050 | 0.704067 | 17482.20 | 17520.91 | 8760.45 | 8760.45 | 0.797843 | 0.797840 | 0.797840 | 0.797840 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 1.06 | 0.530345 | 0.707127 | 17558.19 | 17588.94 | 8794.47 | 8794.47 | 0.798012 | 0.798010 | 0.798010 | 0.798010 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 1.05 | 0.523700 | 0.698267 | 17338.19 | 17392.07 | 8696.03 | 8696.03 | 0.797516 | 0.797510 | 0.797510 | 0.797510 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 1.80 | 0.898955 | 1.20 | 29761.79 | 30378.79 | 15189.40 | 15189.40 | 0.791188 | 0.791190 | 0.791190 | 0.791190 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 0.925170 | 0.462585 | 0.616780 | 15314.85 | 15581.47 | 7790.73 | 7790.73 | 0.792364 | 0.792360 | 0.792360 | 0.792360 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 0.915530 | 0.457765 | 0.610353 | 15155.27 | 15438.56 | 7719.28 | 7719.28 | 0.791909 | 0.791910 | 0.791910 | 0.791910 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 0.903460 | 0.451730 | 0.602307 | 14955.47 | 15259.69 | 7629.85 | 7629.85 | 0.791326 | 0.791330 | 0.791330 | 0.791330 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 1.01 | 0.502865 | 0.670487 | 16648.40 | 16988.69 | 8494.34 | 8494.34 | 0.791291 | 0.791290 | 0.791290 | 0.791290 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.87 | 2001.37 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 1.05 | 1158.64 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.06 | 1169.27 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.06 | 1174.35 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 1.05 | 1159.63 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 1.80 | 1923.85 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 0.925166 | 1024.31 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 0.915526 | 1013.63 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 0.903463 | 1000.28 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 1.01 | 1113.50 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 58604.93 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 31528.53 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 31306.64 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 31812.13 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 31070.23 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 57156.20 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 28531.97 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 28909.66 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 28668.46 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 30713.35 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 8.60 | 2.80 | -4.10 | -8.80 | -2.20 | 0.30 | 6.70 | 10.10 | 16.50 | 20.60 | 19.20 | 14.70 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Great Falls Intl Arpt MT USA TMY3 WMO#=727750 | 47.47 | -111.38 | -7.00 | 1117.00 | 88606 | 1.0531 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 7.03 | 29.40 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 16.911 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 21.211 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 19.785 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 24.085 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.171 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.471 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.171 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.471 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.171 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.471 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 3907.969 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3907.969 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 1983.747 | 5.694 | 66.133 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1983.747 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1492.505 | 8.568 | 99.514 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1492.505 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1211.252 | 6.954 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.252 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1211.252 | 6.954 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.252 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1211.252 | 6.954 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.252 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 3907.969 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3907.969 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.2903 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1381 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.7817E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.1990 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.210 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 7.167 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.72 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.947 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1010000 | 2.1010000 | 2.1010000 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
19 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
20 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
21 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
22 | 7 | -0.37770232E-12 | 0.51790214E-15 | -0.12781252E-12 | 0.55998589E-16 |
23 | 6 | 0.34333646E-07 | 0.85611267E-10 | 0.78179037E-08 | -0.16618826E-12 |
24 | 5 | -0.21846269E-03 | 0.70914283E-06 | -0.11192726E-03 | 0.77079120E-08 |
25 | 4 | 0.32474569 | 0.33518246E-03 | 0.11143489 | -0.38230638E-04 |
26 | 3 | -7.9105893 | 0.10117084E-01 | -2.5301860 | 0.32170091E-01 |
27 | 2 | 42.994418 | 0.35140113E-01 | 16.046370 | -0.35699651 |
28 | 1 | -82.171251 | 0.15534856E-01 | -29.841212 | 1.1132611 |
29 | 0 | 46.824329 | 0.30626733E-03 | 16.275140 | |
30 | 7 | -0.30768122E-08 | -0.20915384E-14 | 0.14239733E-14 | -0.43231278E-16 |
31 | 6 | 0.39835568E-05 | 0.26399824E-08 | 0.31946650E-02 | -0.26799527E-04 |
32 | 5 | -0.27951707E-03 | 0.15609240E-05 | -0.22399710 | 0.19585557E-02 |
33 | 4 | 0.63843515E-02 | 0.70996553E-04 | 4.8340844 | -0.45308610E-01 |
34 | 3 | -0.55922562E-01 | 0.56414668E-03 | -38.047054 | 0.39893714 |
35 | 2 | 0.19837327 | 0.93792475E-03 | 116.53385 | -1.4186067 |
36 | 1 | -0.28619643 | 0.28546699E-03 | -143.93668 | 2.0495227 |
37 | 0 | 0.13950394 | 0.69324754E-05 | 60.838472 | |
38 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223840E-14 | -0.37368711E-16 |
39 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
40 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
41 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
42 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
43 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
44 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
45 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
46 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223844E-14 | -0.37368717E-16 |
47 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
48 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
49 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
50 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
51 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
52 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
53 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
54 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223843E-14 | -0.37368715E-16 |
55 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
56 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
57 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
58 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
59 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
60 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
61 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
62 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223847E-14 | -0.37368722E-16 |
63 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
64 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
65 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
66 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
67 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
68 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
69 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
70 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223844E-14 | -0.37368717E-16 |
71 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
72 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
73 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
74 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
75 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
76 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
77 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
78 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223845E-14 | -0.37368719E-16 |
79 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
80 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
81 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
82 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
83 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
84 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
85 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
86 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223840E-14 | -0.37368711E-16 |
87 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
88 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
89 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
90 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
91 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
92 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
93 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
94 | 7 | -0.54670353E-08 | -0.11613337E-13 | 0.14223844E-14 | -0.37368717E-16 |
95 | 6 | 0.25207632E-05 | 0.15026623E-08 | 0.31993138E-02 | -0.26838525E-04 |
96 | 5 | -0.16410687E-03 | 0.88486983E-06 | -0.22426121 | 0.19608870E-02 |
97 | 4 | 0.36607299E-02 | 0.40162528E-04 | 4.8384812 | -0.45350877E-01 |
98 | 3 | -0.31781560E-01 | 0.31856588E-03 | -38.071881 | 0.39921157 |
99 | 2 | 0.11233251 | 0.52874598E-03 | 116.58215 | -1.4192529 |
100 | 1 | -0.16179893 | 0.16057723E-03 | -143.96511 | 2.0499900 |
101 | 0 | 0.78801674E-01 | 0.38948424E-05 | 60.838472 | |
102 | 7 | -0.21207308E-08 | -0.69128065E-15 | 0.45866753E-14 | -0.60902147E-16 |
103 | 6 | 0.56000727E-05 | 0.38109606E-08 | 0.31899011E-02 | -0.26759564E-04 |
104 | 5 | -0.40083884E-03 | 0.22562489E-05 | -0.22372635 | 0.19561660E-02 |
105 | 4 | 0.92084614E-02 | 0.10268861E-03 | 4.8295754 | -0.45265267E-01 |
106 | 3 | -0.80828076E-01 | 0.81646647E-03 | -38.021585 | 0.39865561 |
107 | 2 | 0.28695633 | 0.13581156E-02 | 116.48428 | -1.4179437 |
108 | 1 | -0.41414885 | 0.41367783E-03 | -143.90750 | 2.0490431 |
109 | 0 | 0.20191061 | 0.10030641E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 29 | 1 | VerySmooth | 2.045 | 0.394 | 0.315 | 0.441 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 3.65598E-002 | 0.31435 | 0.48154 | 0.48154 | 0.44000 | 0.13397 | 0.17027 | 0.00000 | 0.84000 | 0.84000 | 0.11562 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.159 | 4.569E-004 | 2.517E-004 | 0.317 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.241 | 6.922E-004 | 3.813E-004 | 0.481 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 4.561E-002 | 2.619E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 9.122E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.241 | 6.922E-004 | 4.692E-004 | 0.481 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.113 | 6.514E-004 | 3.022E-004 | 0.453 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 3.583E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 18527.47146 | 22232.96575 | 1.55863 | 1.87036 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 33.40000 | 6.26594E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
2 | LGSTORE1 | Heating | 28458.39569 | 34150.07483 | 1.40257 | 1.68308 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
3 | SMSTORE1 | Cooling | 10366.52753 | 12439.83304 | 0.87208 | 1.04650 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 33.26667 | 6.26594E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
4 | SMSTORE1 | Heating | 14316.74114 | 17180.08937 | 0.70559 | 0.84671 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
5 | SMSTORE2 | Cooling | 10551.89565 | 12662.27478 | 0.86284 | 1.03540 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 24.60000 | 6.26593E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
6 | SMSTORE2 | Heating | 14484.63792 | 17381.56550 | 0.71386 | 0.85664 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
7 | SMSTORE3 | Cooling | 10507.03505 | 12608.44206 | 0.88390 | 1.06069 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 33.26667 | 6.26594E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
8 | SMSTORE3 | Heating | 14564.70249 | 17477.64299 | 0.71781 | 0.86137 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
9 | SMSTORE4 | Cooling | 10434.54661 | 12521.45593 | 0.85298 | 1.02358 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 24.60000 | 6.26593E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
10 | SMSTORE4 | Heating | 14708.61853 | 17650.34224 | 0.72490 | 0.86988 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
11 | LGSTORE2 | Cooling | 17809.77771 | 21371.73325 | 1.49826 | 1.79791 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 33.26667 | 6.26594E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
12 | LGSTORE2 | Heating | 27956.60730 | 33547.92876 | 1.37785 | 1.65342 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
13 | SMSTORE5 | Cooling | 9174.29351 | 11009.15221 | 0.74720 | 0.89664 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 27.32000 | 6.26593E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
14 | SMSTORE5 | Heating | 15043.69728 | 18052.43674 | 0.74142 | 0.88970 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
15 | SMSTORE6 | Cooling | 9069.09520 | 10882.91424 | 0.76294 | 0.91553 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 33.26667 | 6.26594E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
16 | SMSTORE6 | Heating | 15026.61594 | 18031.93913 | 0.74058 | 0.88869 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
17 | SMSTORE7 | Cooling | 8949.59956 | 10739.51947 | 0.75289 | 0.90346 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 33.26667 | 6.26594E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
18 | SMSTORE7 | Heating | 15201.90569 | 18242.28683 | 0.74922 | 0.89906 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
19 | SMSTORE8 | Cooling | 8973.19588 | 10767.83506 | 0.75487 | 0.90585 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.00000 | 6.26594E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
20 | SMSTORE8 | Heating | 17005.66743 | 20406.80092 | 0.83810 | 1.00573 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -27.60000 | 3.41898E-004 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 26090.34 | 1.87036 | 1.87036 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 54860.40 | 1.68308 | 1.68308 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 14350.51 | 1.04650 | 1.04650 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 27533.67 | 0.84671 | 0.84671 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 14458.97 | 1.05610 | 1.05610 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 27732.21 | 0.85664 | 0.85664 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 14511.97 | 1.06069 | 1.06069 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 27826.89 | 0.86137 | 0.86137 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 14356.58 | 1.04740 | 1.04740 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 27997.08 | 0.86988 | 0.86988 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 25231.84 | 1.79791 | 1.79791 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 54267.08 | 1.65342 | 1.65342 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 12924.24 | 0.92517 | 0.92517 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 28393.32 | 0.88970 | 0.88970 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 12811.72 | 0.91553 | 0.91553 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 28373.12 | 0.88869 | 0.88869 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 12671.03 | 0.90346 | 0.90346 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 28580.41 | 0.89906 | 0.89906 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 12670.47 | 0.90585 | 0.90585 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 30713.35 | 1.00573 | 1.00573 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.87036 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.04650 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.03540 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.06069 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.02358 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.79791 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.89664 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.91553 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.90346 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00573 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.87036 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.87036 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.87036 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.87036 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.87036 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.87036 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.04650 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.04650 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.04650 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.04650 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04650 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04650 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.03540 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.03540 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.03540 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.03540 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.05610 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.05610 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 0.98040 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.06069 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.06069 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.06069 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.06069 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.06069 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.06069 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.02358 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.02358 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.02358 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.02358 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04740 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 1.04740 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 0.97726 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.79791 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.79791 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.79791 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.79791 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.79791 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 1.79791 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.89664 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.89664 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.89664 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.89664 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92517 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 0.92517 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 0.96916 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.91553 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.91553 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.91553 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.91553 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.91553 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 0.91553 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 1.00000 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.90346 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.90346 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.90346 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.90346 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.90346 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 0.90346 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 1.00000 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00573 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00573 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00573 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00573 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00573 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 1.00573 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 1.00000 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 1.87036 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 1.04650 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.05610 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 1.06069 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 1.04740 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 1.79791 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 0.92517 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 0.91553 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 0.90346 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 1.00573 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.87036 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.87036 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.87036 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.87036 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.23444 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.87036 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.93518 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.24691 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 30961.09916 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 31452.19000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 15726.09500 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15726.09500 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79291 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79291 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79291 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79291 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 31452.19000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 58604.93134 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.87036 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2001.37183 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 58604.93134 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04650 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04650 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04650 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04650 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04650 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04650 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52325 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.69767 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17323.29085 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17378.15000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8689.07500 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 8689.07500 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79749 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79750 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79750 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79750 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17378.15000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31528.52753 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04650 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1158.64330 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31528.52753 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.05610 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.05610 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.05610 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.05610 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.05610 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.05610 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52805 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.70407 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17482.20493 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17520.91000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8760.45500 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 8760.45500 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79784 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79784 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79784 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79784 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17520.91000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31306.64440 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.05610 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1169.26977 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31306.64440 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.06069 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.06069 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.06069 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.06069 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.06069 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.06069 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.53035 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.70713 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17558.18573 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17588.94000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8794.47000 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 8794.47000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79801 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79801 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79801 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79801 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17588.94000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31812.13167 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.06069 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1174.34733 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31812.13167 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04740 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04740 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04740 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04740 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04740 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04740 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52370 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.69827 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17338.18904 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17392.07000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8696.03500 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 8696.03500 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79752 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79751 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79751 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79751 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17392.07000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31070.23320 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04740 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1159.63336 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31070.23320 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.79791 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.79791 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.79791 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.79791 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.18662 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.79791 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.89896 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.19861 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 29761.79440 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 30378.79000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 15189.39500 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15189.39500 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79119 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79119 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79119 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79119 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 30378.79000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 57156.19965 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.79791 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1923.85043 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 57156.19965 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92517 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92517 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92517 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92517 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92517 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.92517 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46259 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.61678 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15314.84854 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15581.47000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7790.73500 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 7790.73500 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79236 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79236 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79236 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79236 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15581.47000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28531.97193 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.92517 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1024.30565 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 28531.97193 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.91553 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.91553 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.91553 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.91553 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.91553 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.91553 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.45777 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.61035 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15155.27231 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15438.56000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7719.28000 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 7719.28000 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79191 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79191 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79191 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79191 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15438.56000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28909.65934 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.91553 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1013.63285 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 28909.65934 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.90346 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.90346 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.90346 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.90346 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.90346 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.90346 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.45173 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.60231 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 14955.47095 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15259.69000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7629.84500 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 7629.84500 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79133 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79133 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79133 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79133 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15259.69000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28668.45868 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.90346 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1000.27716 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 28668.45868 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00573 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00573 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00573 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00573 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.00573 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.00573 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50287 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.67049 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 16648.40258 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 16988.69000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8494.34500 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 8494.34500 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79129 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79129 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79129 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79129 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 16988.69000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 30713.35434 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.00573 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1113.49830 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 30713.35434 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 29986.1 | 11.14 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 16558.0 | 33.28 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 16693.2 | 44.85 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 16757.6 | 56.51 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 16571.2 | 69.00 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 28969.4 | 48.33 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 14856.2 | 112.26 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 14720.9 | 125.21 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 14551.4 | 138.60 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 16200.3 | 136.38 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.138 | 0.134 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 7.817E-002 | 7.671E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.36_SHGC_0.4 | N/A | 2.045 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.290 | 0.278 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.199 | 0.190 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 11 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 2.9616768143E-002 | 0.1762583007 | Pass | Pass | 0.1713399681 | 0.4500449425 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 6.4534872638E-002 | 0.1209845228 | Pass | Pass | 6.7251297915E-002 | 0.2772646342 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 3.1317416318E-002 | 0.1591590259 | Pass | Pass | 0.1446337675 | 0.3803672552 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 3.3928984653E-002 | 0.1914538296 | Pass | Pass | 0.2622339410 | 1.2616921261 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 3.3220219776E-002 | 0.1864260730 | Pass | Pass | 0.2787265237 | 0.9930860325 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 4.1552142854E-002 | 0.2221758542 | Pass | Pass | 0.1241345391 | 0.4395390331 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 4.2405662585E-002 | 0.2246034043 | Pass | Pass | 0.1336873852 | 0.6737191875 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 4.4047214413E-002 | 0.2315047913 | Pass | Pass | 0.1433262369 | 0.7046919569 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 4.9584473165E-002 | 0.2592576048 | Pass | Pass | 8.9118660858E-002 | 0.3254304268 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 6.9860939049E-002 | 0.3587231927 | Pass | Pass | 3.9149471379E-002 | 9.3276316655E-002 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | -27.60 | 0.00 | -27.60 | Wetbulb [C] | 2.70 | 230.00 |
GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 33.40 | 16.00 | 16.30 | Wetbulb [C] | 4.90 | 240.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.278 | 0.290 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.138 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.078 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.078 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.199 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.045 | 0.394 | 0.441 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.045 | 0.394 | 0.441 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.045 | 0.394 | 0.441 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.045 | 0.394 | 0.441 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.36_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.045 | 0.394 | 0.441 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 2.045 | 0.394 | 0.441 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 2.045 | 0.394 | 0.441 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 11.2173 | 348.39 | 3907.97 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 168.00 | 96.33 | 0.0000 | Y | 70.67 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 5.6941 | 348.39 | 1983.75 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 112.00 | 95.26 | 0.0000 | Y | 35.47 |
SMSTORE1_LIGHTS | SMSTORE1 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 168.00 | 96.33 | 0.0000 | Y | 35.33 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 8.5681 | 174.19 | 1492.50 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 112.00 | 95.26 | 0.0000 | Y | 26.69 |
SMSTORE2_LIGHTS | SMSTORE2 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 74.85 | 0.0000 | Y | 27.46 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
SMSTORE3_LIGHTS | SMSTORE3 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 74.85 | 0.0000 | Y | 27.46 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
SMSTORE4_LIGHTS | SMSTORE4 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 74.85 | 0.0000 | Y | 27.46 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
LGSTORE2_LIGHTS | LGSTORE2 | 11.2173 | 348.39 | 3907.97 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 50.13 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 7.3094 | 4180.64 | 30557.82 | 450.89 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 418.40 | AstronomicalClock | - | 42.11 | 42.11 | 3.31 | |
EXTERIOR_LIGHTS_B | 2520.30 | AstronomicalClock | - | 83.57 | 62.84 | 29.73 | |
EXTERIOR_LIGHTS_C | 2520.30 | AstronomicalClock | - | 83.57 | 55.84 | 26.42 | |
Exterior Lighting Total | 5459.01 | 59.45 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 31452.19 | 24938.76 | 6513.43 | 0.79 | 3.80 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17378.15 | 13859.07 | 3519.08 | 0.80 | 4.12 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17520.91 | 13978.88 | 3542.03 | 0.80 | 4.12 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17588.94 | 14036.15 | 3552.79 | 0.80 | 4.12 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 17392.07 | 13870.35 | 3521.72 | 0.80 | 4.12 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 30378.79 | 24035.39 | 6343.40 | 0.79 | 3.80 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15581.47 | 12346.13 | 3235.34 | 0.79 | 4.12 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15438.56 | 12225.95 | 3212.61 | 0.79 | 4.12 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15259.69 | 12075.45 | 3184.24 | 0.79 | 4.12 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 16988.69 | 13442.98 | 3545.71 | 0.79 | 4.12 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 29986.1 | 11.14 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 16558.0 | 33.28 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 16693.2 | 44.85 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 16757.6 | 56.51 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 16571.2 | 69.00 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 28969.4 | 48.33 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 14856.2 | 112.26 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 14720.9 | 125.21 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 14551.4 | 138.60 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 16200.3 | 136.38 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 58604.93 | 0.80 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31528.53 | 0.80 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31306.64 | 0.80 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31812.13 | 0.80 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31070.23 | 0.80 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 57156.20 | 0.80 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 28531.97 | 0.80 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 28909.66 | 0.80 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 28668.46 | 0.80 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 30713.35 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.87 | 2001.37 | 1070.05 | 1.00 | 1.32 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.05 | 1158.64 | 1107.16 | 1.00 | 1.39 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.06 | 1169.27 | 1107.16 | 1.00 | 1.39 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.06 | 1174.35 | 1107.16 | 1.00 | 1.39 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.05 | 1159.63 | 1107.16 | 1.00 | 1.39 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.80 | 1923.85 | 1070.05 | 1.00 | 1.33 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.93 | 1024.31 | 1107.16 | 1.00 | 1.42 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.92 | 1013.63 | 1107.16 | 1.00 | 1.43 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.90 | 1000.28 | 1107.16 | 1.00 | 1.43 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.01 | 1113.50 | 1107.16 | 1.00 | 1.40 | General | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 18527.47 | 22232.97 | 63.82 | 1.559 | 1.870 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 23.89 | 23.89 | 0.00721 | 33.40 | 0.00627 | 0.411 | 0.00 |
SMSTORE1 | 10366.53 | 12439.83 | 71.41 | 0.872 | 1.047 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 23.89 | 23.89 | 0.00718 | 33.27 | 0.00627 | 0.206 | 0.00 |
SMSTORE2 | 10551.90 | 12662.27 | 72.69 | 0.863 | 1.035 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.89 | 23.89 | 0.00757 | 24.60 | 0.00627 | 0.206 | 0.00 |
SMSTORE3 | 10507.04 | 12608.44 | 72.38 | 0.884 | 1.061 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 23.89 | 23.89 | 0.00718 | 33.27 | 0.00627 | 0.206 | 0.00 |
SMSTORE4 | 10434.55 | 12521.46 | 71.88 | 0.853 | 1.024 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 23.89 | 23.89 | 0.00759 | 24.60 | 0.00627 | 0.206 | 0.00 |
LGSTORE2 | 17809.78 | 21371.73 | 61.34 | 1.498 | 1.798 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 23.89 | 23.89 | 0.00722 | 33.27 | 0.00627 | 0.411 | 0.00 |
SMSTORE5 | 9174.29 | 11009.15 | 63.20 | 0.747 | 0.897 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 10:00:00 | 23.89 | 23.89 | 0.00768 | 27.32 | 0.00627 | 0.206 | 0.00 |
SMSTORE6 | 9069.10 | 10882.91 | 62.48 | 0.763 | 0.916 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 23.89 | 23.89 | 0.00721 | 33.27 | 0.00627 | 0.206 | 0.00 |
SMSTORE7 | 8949.60 | 10739.52 | 61.65 | 0.753 | 0.903 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 23.89 | 23.89 | 0.00721 | 33.27 | 0.00627 | 0.206 | 0.00 |
SMSTORE8 | 8973.20 | 10767.84 | 61.82 | 0.755 | 0.906 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 23.89 | 23.89 | 0.00720 | 33.00 | 0.00627 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 28458.40 | 34150.07 | 98.02 | 1.403 | 1.683 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00672 | -27.60 | 0.00034 | 0.411 | 0.00 |
SMSTORE1 | 14316.74 | 17180.09 | 98.63 | 0.706 | 0.847 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00662 | -27.60 | 0.00034 | 0.206 | 0.00 |
SMSTORE2 | 14484.64 | 17381.57 | 99.78 | 0.714 | 0.857 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00663 | -27.60 | 0.00034 | 0.206 | 0.00 |
SMSTORE3 | 14564.70 | 17477.64 | 100.33 | 0.718 | 0.861 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00664 | -27.60 | 0.00034 | 0.206 | 0.00 |
SMSTORE4 | 14708.62 | 17650.34 | 101.33 | 0.725 | 0.870 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00665 | -27.60 | 0.00034 | 0.206 | 0.00 |
LGSTORE2 | 27956.61 | 33547.93 | 96.30 | 1.378 | 1.653 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00672 | -27.60 | 0.00034 | 0.411 | 0.00 |
SMSTORE5 | 15043.70 | 18052.44 | 103.63 | 0.741 | 0.890 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00667 | -27.60 | 0.00034 | 0.206 | 0.00 |
SMSTORE6 | 15026.62 | 18031.94 | 103.52 | 0.741 | 0.889 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00667 | -27.60 | 0.00034 | 0.206 | 0.00 |
SMSTORE7 | 15201.91 | 18242.29 | 104.72 | 0.749 | 0.899 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00668 | -27.60 | 0.00034 | 0.206 | 0.00 |
SMSTORE8 | 17005.67 | 20406.80 | 117.15 | 0.838 | 1.006 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.10 | 0.00676 | -27.60 | 0.00034 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 1.87 | 1.87 | 1.68 | 1.68 | 1.8704 | 1.8704 | 1.8704 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 1.05 | 1.05 | 0.85 | 0.85 | 1.0465 | 1.0465 | 1.0465 | 1.0000 | 1.0000 |
PSZ-AC_3:3 | 1.06 | 1.06 | 0.86 | 0.86 | 1.0561 | 1.0354 | 1.0561 | 0.9804 | 1.0000 |
PSZ-AC_4:4 | 1.06 | 1.06 | 0.86 | 0.86 | 1.0607 | 1.0607 | 1.0607 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 1.05 | 1.05 | 0.87 | 0.87 | 1.0474 | 1.0236 | 1.0474 | 0.9773 | 1.0000 |
PSZ-AC_6:6 | 1.80 | 1.80 | 1.65 | 1.65 | 1.7979 | 1.7979 | 1.7979 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 0.93 | 0.93 | 0.89 | 0.89 | 0.9252 | 0.8966 | 0.9252 | 0.9692 | 1.0000 |
PSZ-AC_8:8 | 0.92 | 0.92 | 0.89 | 0.89 | 0.9155 | 0.9155 | 0.9155 | 1.0000 | 1.0000 |
PSZ-AC_9:9 | 0.90 | 0.90 | 0.90 | 0.90 | 0.9035 | 0.9035 | 0.9035 | 1.0000 | 1.0000 |
PSZ-AC_10:10 | 0.91 | 0.91 | 1.01 | 1.01 | 1.0057 | 1.0057 | 1.0057 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 15726.095 | 0.000 | 1.870360 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 15726.09 | 15726.09 | 1.870360 | 25.98 | 14.42 | 0.00700441 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 21.9986 | 23.89 | 0.00721268 | 34.2536 | 18527.47 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 58604.931 | 58604.931 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 58604.93 | 58604.93 | 1.870358 | 9.20 | 5.80 | 0.00516136 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 21.9986 | 21.10 | 0.00672076 | 37.8343 | 28458.40 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 8689.075 | 0.000 | 1.046500 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8689.08 | 8689.08 | 1.046500 | 25.76 | 14.34 | 0.00700271 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.6585 | 23.89 | 0.00718313 | 34.1147 | 10365.60 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 31528.528 | 31528.528 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31528.53 | 31528.53 | 1.046502 | 9.27 | 5.75 | 0.00509344 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.6585 | 21.10 | 0.00661848 | 37.2655 | 14316.74 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 8760.455 | 0.000 | 1.056100 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8760.45 | 8760.45 | 1.056100 | 25.74 | 14.34 | 0.00700316 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.4799 | 23.89 | 0.00757442 | 35.9549 | 10457.15 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 31306.644 | 31306.644 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31306.64 | 31306.64 | 1.056099 | 9.41 | 5.85 | 0.00511987 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.4799 | 21.10 | 0.00663000 | 37.3297 | 14484.64 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 8794.470 | 0.000 | 1.060690 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8794.47 | 8794.47 | 1.060690 | 25.73 | 14.33 | 0.00700337 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.3956 | 23.89 | 0.00718098 | 34.1046 | 10501.88 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 31812.132 | 31812.132 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31812.13 | 31812.13 | 1.060686 | 9.47 | 5.89 | 0.00513229 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.3956 | 21.10 | 0.00663540 | 37.3598 | 14564.70 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 8696.035 | 0.000 | 1.047400 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8696.03 | 8696.03 | 1.047400 | 25.76 | 14.34 | 0.00700273 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 19.6417 | 23.89 | 0.00759114 | 36.0335 | 10370.72 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 31070.233 | 31070.233 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31070.23 | 31070.23 | 1.047396 | 9.59 | 5.97 | 0.00515437 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 19.6417 | 21.10 | 0.00664506 | 37.4136 | 14708.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 15189.395 | 0.000 | 1.797910 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 15189.40 | 15189.40 | 1.797910 | 26.07 | 14.45 | 0.00700405 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 22.8851 | 23.89 | 0.00722344 | 34.3041 | 17802.79 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 57156.200 | 57156.200 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 57156.20 | 57156.20 | 1.797912 | 8.99 | 5.66 | 0.00513222 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 22.8851 | 21.10 | 0.00671921 | 37.8254 | 27956.61 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 7790.735 | 0.000 | 0.925170 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 7790.73 | 7790.73 | 0.925170 | 26.00 | 14.42 | 0.00699513 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 22.2366 | 23.89 | 0.00767915 | 36.4473 | 9161.67 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 28531.972 | 28531.972 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 28531.97 | 28531.97 | 0.925166 | 9.84 | 6.15 | 0.00520441 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 22.2367 | 21.10 | 0.00666696 | 37.5356 | 15043.70 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 7719.280 | 0.000 | 0.915530 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 7719.28 | 7719.28 | 0.915530 | 26.03 | 14.43 | 0.00699437 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 22.4708 | 23.89 | 0.00720582 | 34.2212 | 9066.69 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 28909.659 | 28909.659 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 28909.66 | 28909.66 | 0.915526 | 9.83 | 6.14 | 0.00520191 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 22.4709 | 21.10 | 0.00666586 | 37.5295 | 15026.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 7629.845 | 0.000 | 0.903460 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 7629.85 | 7629.85 | 0.903460 | 26.06 | 14.44 | 0.00699339 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 22.7710 | 23.89 | 0.00720821 | 34.2324 | 8947.93 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 28668.459 | 28668.459 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 28668.46 | 28668.46 | 0.903463 | 9.96 | 6.23 | 0.00522740 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 22.7709 | 21.10 | 0.00667703 | 37.5917 | 15201.91 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 8494.345 | 0.000 | 1.005730 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 8494.34 | 8494.34 | 1.005730 | 26.06 | 14.43 | 0.00698920 | 12.80 | 10.89 | 0.00850000 | 33.40 | 0.00626594 | 16.30 | 20.4555 | 23.89 | 0.00720353 | 34.2104 | 8947.46 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 30713.354 | 30713.354 | -999.0 | -999.0 | -999.000 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 30713.35 | 30713.35 | 1.005726 | 11.14 | 7.02 | 0.00544574 | 40.00 | 19.60 | 0.00800000 | -27.60 | 0.00034190 | -27.60 | 20.4555 | 21.10 | 0.00675824 | 38.0445 | 17005.67 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15726.095 | 0.000 | 1.870360 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8609 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:20:00 | 15726.09 | 15726.09 | 1.0000 | 1.96975071 | 1.870360 | 25.98 | 14.42 | 0.00700441 | 43963.1 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15726.09 | 33.40 | 0.00626594 | 16.30 | 0.41145340 | 21.9986 | 23.89 | 0.00721268 | 23.89 | 0.00721268 | 34.2536 | 18527.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 58604.931 | 58604.931 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.870358 | 1.96974895 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 58604.93 | 58604.93 | 1.0000 | 1.96974895 | 1.870358 | 9.20 | 5.80 | 0.00516136 | 22240.2 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 58604.93 | -27.60 | 0.00034190 | -27.60 | 0.41145340 | 21.9986 | 21.11 | 0.00672076 | 21.10 | 0.00672076 | 37.8343 | 28458.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 8689.075 | 0.000 | 1.046500 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8577 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8689.08 | 8689.08 | 1.0000 | 1.10211088 | 1.046500 | 25.76 | 14.34 | 0.00700271 | 43732.5 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8689.08 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 19.6585 | 23.89 | 0.00718300 | 23.89 | 0.00718313 | 34.1147 | 10365.60 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31528.528 | 31528.528 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.046502 | 1.10211248 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31528.53 | 31528.53 | 1.0000 | 1.10211248 | 1.046502 | 9.27 | 5.75 | 0.00509344 | 22142.7 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31528.53 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 19.6585 | 21.11 | 0.00661848 | 21.10 | 0.00661848 | 37.2655 | 14316.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 8760.455 | 0.000 | 1.056100 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8585 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8760.45 | 8760.45 | 1.0000 | 1.11222103 | 1.056100 | 25.74 | 14.34 | 0.00700316 | 43717.0 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8760.45 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 19.4799 | 23.89 | 0.00718160 | 23.89 | 0.00757442 | 35.9549 | 10457.15 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31306.644 | 31306.644 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.056099 | 1.11222049 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31306.64 | 31306.64 | 1.0000 | 1.11222049 | 1.056099 | 9.41 | 5.85 | 0.00511987 | 22348.4 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31306.64 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 19.4799 | 21.11 | 0.00663000 | 21.10 | 0.00663000 | 37.3297 | 14484.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 8794.470 | 0.000 | 1.060690 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8589 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8794.47 | 8794.47 | 1.0000 | 1.11705494 | 1.060690 | 25.73 | 14.33 | 0.00700337 | 43709.5 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8794.47 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 19.3956 | 23.89 | 0.00718093 | 23.89 | 0.00718098 | 34.1046 | 10501.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31812.132 | 31812.132 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.060686 | 1.11705031 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31812.13 | 31812.13 | 1.0000 | 1.11705031 | 1.060686 | 9.47 | 5.89 | 0.00513229 | 22444.9 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31812.13 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 19.3956 | 21.11 | 0.00663540 | 21.10 | 0.00663540 | 37.3598 | 14564.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 8696.035 | 0.000 | 1.047400 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8577 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 8696.03 | 8696.03 | 1.0000 | 1.10305871 | 1.047400 | 25.76 | 14.34 | 0.00700273 | 43731.6 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8696.03 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 19.6417 | 23.89 | 0.00718293 | 23.89 | 0.00759114 | 36.0335 | 10370.72 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31070.233 | 31070.233 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.047396 | 1.10305424 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 31070.23 | 31070.23 | 1.0000 | 1.10305424 | 1.047396 | 9.59 | 5.97 | 0.00515437 | 22616.0 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31070.23 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 19.6417 | 21.11 | 0.00664506 | 21.10 | 0.00664506 | 37.4136 | 14708.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15189.395 | 0.000 | 1.797910 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8602 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 15189.40 | 15189.40 | 1.0000 | 1.89345072 | 1.797910 | 26.07 | 14.45 | 0.00700405 | 44048.9 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15189.40 | 33.40 | 0.00626594 | 16.30 | 0.41145340 | 22.8851 | 23.89 | 0.00722320 | 23.89 | 0.00722344 | 34.3041 | 17802.79 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 57156.200 | 57156.200 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.797912 | 1.89345243 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 57156.20 | 57156.20 | 1.0000 | 1.89345243 | 1.797912 | 8.99 | 5.66 | 0.00513222 | 21950.2 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 57156.20 | -27.60 | 0.00034190 | -27.60 | 0.41145340 | 22.8851 | 21.11 | 0.00671921 | 21.10 | 0.00671921 | 37.8254 | 27956.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 7790.735 | 0.000 | 0.925170 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8436 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 7790.73 | 7790.73 | 1.0000 | 0.97433342 | 0.925170 | 26.00 | 14.42 | 0.00699513 | 43963.3 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7790.73 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 22.2366 | 23.89 | 0.00720373 | 23.89 | 0.00767915 | 36.4473 | 9161.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28531.972 | 28531.972 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.925166 | 0.97432924 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 28531.97 | 28531.97 | 1.0000 | 0.97432924 | 0.925166 | 9.84 | 6.15 | 0.00520441 | 23002.3 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28531.97 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 22.2367 | 21.11 | 0.00666696 | 21.10 | 0.00666696 | 37.5356 | 15043.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 7719.280 | 0.000 | 0.915530 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8422 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 7719.28 | 7719.28 | 1.0000 | 0.96418115 | 0.915530 | 26.03 | 14.43 | 0.00699437 | 43983.9 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7719.28 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 22.4708 | 23.89 | 0.00720558 | 23.89 | 0.00720582 | 34.2212 | 9066.69 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28909.659 | 28909.659 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.915526 | 0.96417717 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 28909.66 | 28909.66 | 1.0000 | 0.96417717 | 0.915526 | 9.83 | 6.14 | 0.00520191 | 22983.0 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28909.66 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 22.4709 | 21.11 | 0.00666586 | 21.10 | 0.00666586 | 37.5295 | 15026.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 7629.845 | 0.000 | 0.903460 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8404 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | 7629.85 | 7629.85 | 1.0000 | 0.95146976 | 0.903460 | 26.06 | 14.44 | 0.00699339 | 44010.3 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7629.85 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 22.7710 | 23.89 | 0.00720793 | 23.89 | 0.00720821 | 34.2324 | 8947.93 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28668.459 | 28668.459 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.903463 | 0.95147311 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 28668.46 | 28668.46 | 1.0000 | 0.95147311 | 0.903463 | 9.96 | 6.23 | 0.00522740 | 23179.2 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28668.46 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 22.7709 | 21.11 | 0.00667703 | 21.10 | 0.00667703 | 37.5917 | 15201.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 8494.345 | 0.000 | 1.005730 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1017.8326 | 1004.8586 | 1.0531 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | GREAT FALLS INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 8494.34 | 8494.34 | 1.0000 | 1.05917437 | 1.005730 | 26.06 | 14.43 | 0.00698920 | 43999.7 | 12.80 | 10.89 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 8494.34 | 33.40 | 0.00626594 | 16.30 | 0.20572670 | 20.4555 | 23.89 | 0.00720252 | 23.89 | 0.00720353 | 34.2104 | 8947.46 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 30713.354 | 30713.354 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0531 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.005726 | 1.05917014 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | GREAT FALLS INTL ARPT ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 30713.35 | 30713.35 | 1.0000 | 1.05917014 | 1.005726 | 11.14 | 7.02 | 0.00544574 | 24928.8 | 40.00 | 19.60 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 30713.35 | -27.60 | 0.00034190 | -27.60 | 0.20572670 | 20.4555 | 21.11 | 0.00675824 | 21.10 | 0.00675824 | 38.0445 | 17005.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC_1:1_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.87 | - | |||
PSZ-AC_2:2_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.05 | - | |||
PSZ-AC_3:3_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.06 | - | |||
PSZ-AC_4:4_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.06 | - | |||
PSZ-AC_5:5_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.05 | - | |||
PSZ-AC_6:6_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.80 | - | |||
PSZ-AC_10:10_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 1.01 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 1924.83 | 4164.50 | 1322.50 |
SMSTORE1 | 1304.83 | 3866.00 | 668.33 |
SMSTORE2 | 1331.83 | 2890.00 | 732.67 |
SMSTORE3 | 1404.50 | 2928.33 | 810.00 |
SMSTORE4 | 1478.17 | 3015.83 | 925.17 |
LGSTORE2 | 1527.83 | 2963.33 | 1167.67 |
SMSTORE5 | 1496.83 | 2973.17 | 1208.33 |
SMSTORE6 | 1532.50 | 2989.33 | 1256.67 |
SMSTORE7 | 1644.83 | 3045.50 | 1392.17 |
SMSTORE8 | 1979.50 | 3171.00 | 1754.50 |
Facility | 3034.33 | 4660.83 | 2287.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 9.17 | 0.00 | 2.00 | 0.00 |
SMSTORE1 | 1.67 | 0.00 | 0.17 | 0.00 |
SMSTORE2 | 1.17 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 1.83 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 2.00 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 4.33 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 4.17 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 4.33 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 6.33 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 33.00 | 0.00 | 0.00 | 0.00 |
Facility | 41.83 | 0.00 | 2.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.939 | 0.241 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.990 | 0.253 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 1.165 | 0.329 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 1.161 | 0.329 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 1.136 | 0.329 | 0.000 | 0.000 |
LGSTORE2 | 13.21 | 30.00 | 1805.20 | 0.940 | 0.316 | 0.000 | 0.000 |
SMSTORE5 | 6.60 | 15.00 | 902.60 | 0.830 | 0.351 | 0.000 | 0.000 |
SMSTORE6 | 6.60 | 15.00 | 902.60 | 0.830 | 0.351 | 0.000 | 0.000 |
SMSTORE7 | 6.60 | 15.00 | 902.60 | 0.830 | 0.351 | 0.000 | 0.000 |
SMSTORE8 | 6.60 | 15.00 | 902.60 | 1.039 | 0.377 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.804 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.804 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.804 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.21 | 30.00 | 1805.20 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.60 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.60 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.60 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.60 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
Electricity:Building | 579.04 | 891.83 | 01-JAN-00:20 | 37073.46 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 132.39 | 148.64 | 01-JAN-00:20 | 6930.31 | 01-JAN-10:10 |
InteriorLights:Electricity | 450.89 | 450.00 | 01-JAN-00:20 | 29013.96 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 106.14 | 75.00 | 01-JAN-00:20 | 5587.06 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 450.89 | 450.00 | 01-JAN-00:20 | 29013.96 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 75.15 | 74.32 | 01-JAN-00:20 | 3939.90 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 62.02 | 37.50 | 01-JAN-00:20 | 3268.27 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 54.53 | 74.32 | 01-JAN-00:10 | 3678.60 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 44.11 | 37.50 | 01-JAN-00:10 | 3006.97 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 54.53 | 74.32 | 01-JAN-00:10 | 3678.60 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 44.11 | 37.50 | 01-JAN-00:10 | 3006.97 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 54.53 | 74.32 | 01-JAN-00:10 | 3678.60 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 44.11 | 37.50 | 01-JAN-00:10 | 3006.97 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 69.31 | 148.64 | 01-JAN-00:10 | 5055.82 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 50.13 | 75.00 | 01-JAN-00:10 | 3712.57 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.15 | 441.83 | 01-JAN-00:10 | 8059.50 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.25 | 73.64 | 01-JAN-00:10 | 1343.25 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.15 | 441.83 | 01-JAN-00:10 | 8059.50 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.12 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.17 | 73.64 | 01-JAN-00:10 | 1343.25 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
Electricity:Plant | 65.79 | 1211.00 | 06-JAN-00:20 | 14008.81 | 21-JAN-14:20 |
WaterSystems:Electricity | 65.79 | 1211.00 | 06-JAN-00:20 | 14008.81 | 21-JAN-14:20 |
Water Heater:WaterSystems:Electricity | 65.79 | 1211.00 | 06-JAN-00:20 | 14008.81 | 21-JAN-14:20 |
ElectricityPurchased:Facility | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
ElectricityPurchased:Plant | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
Cogeneration:ElectricityPurchased | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
ElectricityNet:Plant | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
Cogeneration:ElectricityNet | 933.05 | 2102.83 | 19-FEB-07:40 | 91682.11 | 17-JUL-16:40 |
Electricity:HVAC | 228.77 | 0.00 | 01-JAN-00:10 | 48538.16 | 17-JUL-16:10 |
Fans:Electricity | 179.12 | 0.00 | 01-JAN-00:10 | 11969.69 | 08-JAN-18:00 |
General:Fans:Electricity | 179.12 | 0.00 | 01-JAN-00:10 | 11969.69 | 08-JAN-18:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 49.65 | 0.00 | 01-JAN-00:10 | 36924.20 | 17-JUL-16:10 |
ExteriorLights:Electricity | 59.45 | 0.00 | 01-JAN-08:20 | 5459.01 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 59.45 | 0.00 | 01-JAN-08:20 | 5459.01 | 01-JAN-06:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 587.08 | 0.00 | 01-JAN-00:10 | 302456.48 | 08-JAN-18:00 |
Gas:HVAC | 587.08 | 0.00 | 01-JAN-00:10 | 302456.48 | 08-JAN-18:00 |
Heating:Gas | 587.08 | 0.00 | 01-JAN-00:10 | 302456.48 | 08-JAN-18:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1138.81 | 0.00 | 01-JAN-00:10 | 370893.80 | 09-JAN-08:10 |
EnergyTransfer:Building | 458.44 | 0.00 | 01-JAN-00:10 | 173104.48 | 09-JAN-08:10 |
EnergyTransfer:Zone:LGSTORE1 | 93.28 | 0.00 | 01-JAN-00:10 | 33272.37 | 27-JAN-08:10 |
Heating:EnergyTransfer | 168.13 | 0.00 | 01-JAN-00:10 | 173104.48 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 23.57 | 0.00 | 01-JAN-00:10 | 33272.37 | 27-JAN-08:10 |
Cooling:EnergyTransfer | 290.32 | 0.00 | 01-JAN-00:10 | 86655.04 | 17-JUL-16:10 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 69.71 | 0.00 | 01-JAN-00:10 | 19355.01 | 28-JAN-00:10 |
EnergyTransfer:Zone:SMSTORE1 | 47.26 | 0.00 | 01-JAN-00:10 | 13710.41 | 11-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 8.07 | 0.00 | 01-JAN-00:10 | 13710.41 | 11-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 39.18 | 0.00 | 01-JAN-00:10 | 10929.31 | 27-JUL-20:20 |
EnergyTransfer:Zone:SMSTORE2 | 38.12 | 0.00 | 01-JAN-00:10 | 15032.59 | 09-JAN-07:10 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 9.97 | 0.00 | 01-JAN-00:10 | 15032.59 | 09-JAN-07:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 28.15 | 0.00 | 01-JAN-00:10 | 7792.10 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE3 | 38.06 | 0.00 | 01-JAN-00:10 | 16188.74 | 09-JAN-07:10 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 10.84 | 0.00 | 01-JAN-00:10 | 16188.74 | 09-JAN-07:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 27.22 | 0.00 | 01-JAN-00:10 | 7839.61 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE4 | 37.08 | 0.00 | 01-JAN-00:10 | 16101.25 | 29-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 12.23 | 0.00 | 01-JAN-00:10 | 16101.25 | 29-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 24.85 | 0.00 | 01-JAN-00:10 | 7724.00 | 17-JUL-16:10 |
EnergyTransfer:Zone:LGSTORE2 | 64.27 | 0.00 | 01-JAN-00:10 | 32588.36 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 26.47 | 0.00 | 01-JAN-00:10 | 32588.36 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 37.80 | 0.00 | 01-JAN-00:10 | 13435.92 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE5 | 33.02 | 0.00 | 01-JAN-00:10 | 17225.12 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 15.35 | 0.00 | 01-JAN-00:10 | 17225.12 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 17.67 | 0.00 | 01-JAN-00:10 | 7041.13 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE6 | 32.94 | 0.00 | 01-JAN-00:10 | 17329.33 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 15.78 | 0.00 | 01-JAN-00:10 | 17329.33 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 17.15 | 0.00 | 01-JAN-00:10 | 6984.22 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE7 | 33.42 | 0.00 | 01-JAN-00:10 | 17265.58 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 17.78 | 0.00 | 01-JAN-00:10 | 17265.58 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 15.63 | 0.00 | 01-JAN-00:10 | 6890.36 | 17-JUL-16:10 |
EnergyTransfer:Zone:SMSTORE8 | 41.00 | 0.00 | 01-JAN-00:10 | 19662.41 | 09-JAN-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 28.06 | 0.00 | 01-JAN-00:10 | 19662.41 | 09-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 12.94 | 0.00 | 01-JAN-00:10 | 7001.30 | 17-JUL-16:10 |
EnergyTransfer:HVAC | 680.36 | 0.00 | 01-JAN-00:10 | 241965.19 | 08-JAN-18:00 |
HeatingCoils:EnergyTransfer | 469.67 | 0.00 | 01-JAN-00:10 | 241965.19 | 08-JAN-18:00 |
CoolingCoils:EnergyTransfer | 210.70 | 0.00 | 01-JAN-00:10 | 132914.96 | 17-JUL-16:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 23.566 | -69.709 | 0.000 | 0.000 | 13.615 | 106.140 | 26.249 | 23.118 | 0.000 | 1.726 | 0.001 | 0.000 | -12.590 | 0.000 | -43.483 | -68.633 |
SMSTORE1 | 0.000 | 0.000 | 8.073 | -39.184 | 0.000 | 0.000 | 6.654 | 62.022 | 13.125 | 11.450 | 0.000 | 0.931 | 0.002 | 0.000 | -6.590 | 0.000 | -21.054 | -35.428 |
SMSTORE2 | 0.000 | 0.000 | 9.973 | -28.150 | 0.000 | 0.000 | 4.050 | 44.110 | 10.421 | 11.433 | 0.000 | 0.913 | 0.000 | 0.000 | -6.515 | 0.000 | -21.703 | -24.533 |
SMSTORE3 | 0.000 | 0.000 | 10.838 | -27.224 | 0.000 | 0.000 | 4.057 | 44.110 | 10.421 | 11.448 | 0.000 | 0.913 | 0.001 | 0.000 | -6.455 | 0.000 | -21.619 | -26.489 |
SMSTORE4 | 0.000 | 0.000 | 12.229 | -24.850 | 0.000 | 0.000 | 4.069 | 44.110 | 10.421 | 11.477 | 0.000 | 0.913 | 0.000 | 0.000 | -6.382 | 0.000 | -21.494 | -30.494 |
LGSTORE2 | 0.000 | 0.000 | 26.467 | -37.800 | 0.000 | 0.000 | 14.104 | 50.132 | 19.173 | 23.100 | 0.000 | 1.650 | 0.002 | 0.000 | -12.356 | 0.000 | -39.262 | -45.208 |
SMSTORE5 | 0.000 | 0.000 | 15.350 | -17.673 | 0.000 | 0.000 | 7.025 | 25.066 | 9.586 | 11.529 | 0.000 | 0.916 | 0.002 | 0.000 | -6.194 | 0.000 | -21.433 | -24.172 |
SMSTORE6 | 0.000 | 0.000 | 15.784 | -17.154 | 0.000 | 0.000 | 7.029 | 25.066 | 9.586 | 11.539 | 0.000 | 0.916 | 0.001 | 0.000 | -6.173 | 0.000 | -21.403 | -25.191 |
SMSTORE7 | 0.000 | 0.000 | 17.783 | -15.633 | 0.000 | 0.000 | 7.043 | 25.066 | 9.586 | 11.567 | 0.000 | 0.916 | 0.000 | 0.000 | -6.094 | 0.000 | -21.285 | -28.950 |
SMSTORE8 | 0.000 | 0.000 | 28.064 | -12.940 | 0.000 | 0.000 | 7.068 | 25.066 | 9.586 | 11.649 | 0.000 | 0.968 | 0.001 | 0.000 | -5.804 | 0.000 | -27.614 | -36.044 |
Total Facility | 0.000 | 0.000 | 168.127 | -290.316 | 0.000 | 0.000 | 74.715 | 450.890 | 128.154 | 138.311 | 0.000 | 10.762 | 0.009 | 0.000 | -75.153 | 0.000 | -260.349 | -345.141 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 04-SEP-07:02 | 0.00 | 0.00 | 0.00 | -31752.66 | 0.00 | 0.00 | 96.00 | 75.00 | 74.62 | 135.69 | 0.00 | 0.00 | 31543.74 | 0.00 | -0.00 | 0.00 | -172.40 | 0.00 |
SMSTORE1 | 08-SEP-20:30 | 0.00 | 0.00 | 0.00 | -20775.79 | 0.00 | 0.00 | 355.04 | 3268.27 | 671.63 | 0.00 | 0.00 | 0.00 | 16736.70 | 0.00 | -226.56 | 0.00 | -29.29 | 0.00 |
SMSTORE2 | 27-JUL-06:02 | 0.00 | 0.00 | 0.00 | -20426.63 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 20507.40 | 0.00 | -126.00 | 0.00 | -29.10 | 0.00 |
SMSTORE3 | 27-JUL-06:02 | 0.00 | 0.00 | 0.00 | -20540.17 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 20621.73 | 0.00 | -126.69 | 0.00 | -29.18 | 0.00 |
SMSTORE4 | 03-SEP-07:02 | 0.00 | 0.00 | 0.00 | -19293.39 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 12.27 | 0.00 | 0.00 | 19336.97 | 0.00 | -0.00 | 0.00 | -130.65 | 0.00 |
LGSTORE2 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -31335.32 | 0.00 | 0.00 | 0.00 | 75.00 | 73.64 | 0.00 | 0.00 | 0.00 | 31436.29 | 0.00 | -16.99 | 0.00 | -232.62 | 0.00 |
SMSTORE5 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -13607.43 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 13670.75 | 0.00 | -8.04 | 0.00 | -129.61 | 0.00 |
SMSTORE6 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -13484.76 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 13546.51 | 0.00 | -7.26 | 0.00 | -128.81 | 0.00 |
SMSTORE7 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -13321.69 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 13379.02 | 0.00 | -5.41 | 0.00 | -126.23 | 0.00 |
SMSTORE8 | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -16842.91 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.67 | 0.00 | 0.00 | 16904.74 | 0.00 | -0.00 | 0.00 | -136.81 | 0.00 |
Total Facility | 05-SEP-07:02 | 0.00 | 0.00 | 0.00 | -145004.34 | 0.00 | 0.00 | 300.67 | 450.00 | 1452.23 | 15.30 | 0.00 | 0.00 | 144255.40 | 0.00 | -40.16 | 0.00 | -1429.10 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 27-JAN-08:12 | 0.00 | 0.00 | 58974.62 | 0.00 | 0.00 | 0.00 | 0.00 | 75.00 | 73.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -823.17 | 0.00 | -2567.57 | -55732.52 |
SMSTORE1 | 08-JAN-08:61 | 0.00 | 0.00 | 31592.43 | 0.00 | 0.00 | 0.00 | 72.66 | 37.50 | 37.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -756.45 | 0.00 | -1015.36 | -29968.09 |
SMSTORE2 | 08-JAN-08:61 | 0.00 | 0.00 | 31384.05 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -743.83 | 0.00 | -1000.97 | -29714.07 |
SMSTORE3 | 05-FEB-08:61 | 0.00 | 0.00 | 31873.07 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -313.02 | 0.00 | -905.55 | -30729.31 |
SMSTORE4 | 05-FEB-08:61 | 0.00 | 0.00 | 31156.38 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -307.98 | 0.00 | -898.17 | -30025.04 |
LGSTORE2 | 08-JAN-09:12 | 0.00 | 0.00 | 57563.85 | 0.00 | 0.00 | 0.00 | 0.00 | 75.00 | 73.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -928.16 | 0.00 | -2019.83 | -54764.49 |
SMSTORE5 | 08-JAN-09:12 | 0.00 | 0.00 | 28867.19 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -463.83 | 0.00 | -1114.81 | -27362.87 |
SMSTORE6 | 08-JAN-09:12 | 0.00 | 0.00 | 29221.12 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -464.38 | 0.00 | -1119.60 | -27711.47 |
SMSTORE7 | 08-JAN-09:12 | 0.00 | 0.00 | 29010.40 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -462.40 | 0.00 | -1118.14 | -27504.18 |
SMSTORE8 | 08-JAN-09:12 | 0.00 | 0.00 | 31141.48 | 0.00 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -450.70 | 0.00 | -1180.09 | -29585.02 |
Total Facility | 09-JAN-08:61 | 0.00 | 0.00 | 289991.43 | 0.00 | 0.00 | 0.00 | 411.21 | 450.00 | 1452.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -9119.03 | 0.00 | -12215.28 | -270970.56 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.8704 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8704 | 0.2200 | 1.0000 | 0.4115 | 0.2200 | ||
PSZ-AC_2:2 | 1.0465 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0465 | 0.1966 | 1.0000 | 0.2057 | 0.1966 | ||
PSZ-AC_3:3 | 1.0354 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0561 | 0.1948 | 1.0000 | 0.2057 | 0.1948 | ||
PSZ-AC_4:4 | 1.0607 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0607 | 0.1940 | 1.0000 | 0.2057 | 0.1940 | ||
PSZ-AC_5:5 | 1.0236 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0474 | 0.1964 | 1.0000 | 0.2057 | 0.1964 | ||
PSZ-AC_6:6 | 1.7979 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.7979 | 0.2289 | 1.0000 | 0.4115 | 0.2289 | ||
PSZ-AC_7:7 | 0.8966 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9252 | 0.2224 | 1.0000 | 0.2057 | 0.2224 | ||
PSZ-AC_8:8 | 0.9155 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9155 | 0.2247 | 1.0000 | 0.2057 | 0.2247 | ||
PSZ-AC_9:9 | 0.9035 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9035 | 0.2277 | 1.0000 | 0.2057 | 0.2277 | ||
PSZ-AC_10:10 | 1.0057 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0057 | 0.2271 | 1.0000 | 0.2057 | 0.2046 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.8704 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8704 | 1.0000 | 1.0000 | 0.4115 | 0.2200 | ||
PSZ-AC_2:2 | 1.0465 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0465 | 1.0000 | 1.0000 | 0.2057 | 0.1966 | ||
PSZ-AC_3:3 | 1.0354 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0354 | 1.0000 | 1.0000 | 0.2057 | 0.1987 | ||
PSZ-AC_4:4 | 1.0607 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0607 | 1.0000 | 1.0000 | 0.2057 | 0.1940 | ||
PSZ-AC_5:5 | 1.0236 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0236 | 1.0000 | 1.0000 | 0.2057 | 0.2010 | ||
PSZ-AC_6:6 | 1.7979 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.7979 | 1.0000 | 1.0000 | 0.4115 | 0.2289 | ||
PSZ-AC_7:7 | 0.8966 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8966 | 1.0000 | 1.0000 | 0.2057 | 0.2294 | ||
PSZ-AC_8:8 | 0.9155 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9155 | 1.0000 | 1.0000 | 0.2057 | 0.2247 | ||
PSZ-AC_9:9 | 0.9035 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9035 | 1.0000 | 1.0000 | 0.2057 | 0.2277 | ||
PSZ-AC_10:10 | 1.0057 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0057 | 1.0000 | 1.0000 | 0.2057 | 0.2046 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.8704 | 1.8704 | 1.8704 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.0465 | 1.0465 | 1.0465 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.0354 | 1.0354 | 1.0354 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.0607 | 1.0607 | 1.0607 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.0236 | 1.0236 | 1.0236 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.7979 | 1.7979 | 1.7979 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.8966 | 0.8966 | 0.8966 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.9155 | 0.9155 | 0.9155 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.9035 | 0.9035 | 0.9035 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.0057 | 1.0057 | 1.0057 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.8704 | 1.8704 | 1.8704 | 1.8704 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.0465 | 1.0465 | 1.0465 | 1.0465 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0354 | 1.0561 | 1.0354 | 1.0354 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.0607 | 1.0607 | 1.0607 | 1.0607 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0236 | 1.0474 | 1.0236 | 1.0236 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.7979 | 1.7979 | 1.7979 | 1.7979 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.8966 | 0.9252 | 0.8966 | 0.8966 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.9155 | 0.9155 | 0.9155 | 0.9155 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.9035 | 0.9035 | 0.9035 | 0.9035 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.0057 | 1.0057 | 1.0057 | 1.0057 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.8704 | 1.8704 | 1.8704 | 0.4115 | 0.2445 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.0465 | 1.0465 | 1.0465 | 0.2057 | 0.2430 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.0354 | 1.0354 | 1.0354 | 0.2057 | 0.2402 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.0607 | 1.0607 | 1.0607 | 0.2057 | 0.2388 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.0236 | 1.0236 | 1.0236 | 0.2057 | 0.2365 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.7979 | 1.7979 | 1.7979 | 0.4115 | 0.2489 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.8966 | 0.8966 | 0.8966 | 0.2057 | 0.2312 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.9155 | 0.9155 | 0.9155 | 0.2057 | 0.2315 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.9035 | 0.9035 | 0.9035 | 0.2057 | 0.2288 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.0057 | 1.0057 | 1.0057 | 0.2057 | 0.2046 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.8704 | 1.8704 | 1.8704 | 1.8704 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.0465 | 1.0465 | 1.0465 | 1.0465 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0354 | 1.0354 | 1.0354 | 1.0354 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.0607 | 1.0607 | 1.0607 | 1.0607 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0236 | 1.0236 | 1.0236 | 1.0236 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.7979 | 1.7979 | 1.7979 | 1.7979 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.8966 | 0.8966 | 0.8966 | 0.8966 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.9155 | 0.9155 | 0.9155 | 0.9155 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.9035 | 0.9035 | 0.9035 | 0.9035 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.0057 | 1.0057 | 1.0057 | 1.0057 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:21:27
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Great Falls Intl Arpt MT USA TMY3 WMO#=727750 |
Total gross floor area [m2] | 2090.32 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 2.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 2.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 587.08 | 302456.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 49.65 | 36924.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 450.89 | 29013.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 59.45 | 5459.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.15 | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 179.12 | 11969.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 65.79 | 14008.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.15 | 933.05 |
Natural Gas | 0.00 | 587.08 |
Additional | 0.00 | 0.00 |
Total | 128.15 | 1520.13 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 215.70 |
Space Heating | 0.00 |
Space Cooling | 23.75 |
Fans (All) | 85.69 |
Service Water Heating | 31.47 |
Receptacle Equipment | 61.31 |
Miscellaneous (All) | 446.37 |
Subtotal | 446.37 |
Natural Gas [MJ/m2] | |
Space Heating | 280.86 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 280.86 |
Subtotal | 280.86 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 29.66 |
Space Heating | 38.62 |
Space Cooling | 3.27 |
Fans (All) | 11.78 |
Service Water Heating | 4.33 |
Receptacle Equipment | 8.43 |
Miscellaneous | 3.91 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5122. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4868. | 8760. |
TYPE2_EQUIP_SCH | 3893. | 8760. |
TYPE3_EQUIP_SCH | 3584. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 6B
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MT_GREATFALLS
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.172002E+12 |
February | 0.000 | 0.968417E+11 |
March | 0.000 | 0.773610E+11 |
April | 0.000 | 0.301957E+11 |
May | 0.000 | 0.188946E+11 |
June | 0.000 | 0.509442E+09 |
July | 0.000 | 0.000 |
August | 0.000 | 0.126804E+08 |
September | 0.000 | 0.271566E+10 |
October | 0.000 | 0.114614E+11 |
November | 0.000 | 0.534474E+11 |
December | 0.000 | 0.123640E+12 |
Annual Sum or Average | 0.587081E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.172002E+12 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.967252E+09 | 20520.43 | 28-JAN-00:01 | -29.2 | -29.5 | 0.567878E+09 | 680.12 | 13-JAN-13:39 | 6.50 | 2.60 |
February | 0.193562E+10 | 17029.54 | 04-FEB-00:01 | -21.0 | -21.3 | 0.518770E+09 | 818.22 | 26-FEB-17:10 | 14.85 | 5.61 |
March | 0.248334E+10 | 15377.85 | 04-MAR-00:01 | -17.2 | -17.7 | 0.563916E+09 | 680.12 | 10-MAR-13:09 | 8.72 | 4.37 |
April | 0.374997E+10 | 9933.00 | 28-APR-23:03 | -4.6 | -6.1 | 0.589599E+09 | 898.99 | 16-APR-17:19 | 19.80 | 8.87 |
May | 0.539048E+10 | 8938.95 | 20-MAY-16:10 | 29.82 | 15.08 | 0.658254E+09 | 899.01 | 19-MAY-12:09 | 24.27 | 14.49 |
June | 0.897099E+10 | 12282.96 | 22-JUN-07:03 | 19.37 | 14.44 | 0.710780E+09 | 899.02 | 04-JUN-12:09 | 23.12 | 14.05 |
July | 0.125129E+11 | 27158.36 | 17-JUL-07:02 | 23.17 | 14.92 | 0.753039E+09 | 899.01 | 16-JUL-16:00 | 33.30 | 17.40 |
August | 0.119492E+11 | 28928.19 | 07-AUG-07:02 | 22.77 | 12.36 | 0.738392E+09 | 899.07 | 06-AUG-16:10 | 35.50 | 16.21 |
September | 0.957112E+10 | 31752.63 | 04-SEP-07:02 | 20.02 | 12.32 | 0.695692E+09 | 899.07 | 10-SEP-12:00 | 18.30 | 13.27 |
October | 0.699702E+10 | 8927.23 | 18-OCT-14:00 | 25.00 | 11.37 | 0.661693E+09 | 898.99 | 22-OCT-17:19 | 15.57 | 7.64 |
November | 0.369470E+10 | 13977.97 | 26-NOV-18:20 | -13.9 | -15.0 | 0.567616E+09 | 845.65 | 04-NOV-12:00 | 16.70 | 8.09 |
December | 0.148711E+10 | 18089.55 | 29-DEC-00:01 | -23.6 | -23.9 | 0.570794E+09 | 680.12 | 09-DEC-13:09 | 3.95 | 0.92 |
Annual Sum or Average | 0.697097E+11 | 0.759642E+10 | ||||||||
Minimum of Months | 0.967252E+09 | 8927.23 | -29.2 | -29.5 | 0.518770E+09 | 680.12 | 3.95 | 0.92 | ||
Maximum of Months | 0.125129E+11 | 31752.63 | 29.82 | 15.08 | 0.753039E+09 | 899.07 | 35.50 | 17.40 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.456448E+09 | 5977.57 | 06-JAN-18:42 | -13.6 | -14.6 | 0.291161E+09 | 410.42 | 01-JAN-18:00 | 2.80 | -0.1 |
February | 0.828906E+09 | 3952.30 | 22-FEB-09:43 | -4.3 | -5.3 | 0.275068E+09 | 449.50 | 26-FEB-17:19 | 14.10 | 5.33 |
March | 0.129493E+10 | 3709.06 | 01-MAR-09:03 | -2.3 | -3.4 | 0.299657E+09 | 428.30 | 26-MAR-17:00 | 8.90 | 1.04 |
April | 0.180707E+10 | 18198.49 | 25-APR-20:02 | 12.12 | 5.44 | 0.323792E+09 | 449.50 | 16-APR-16:10 | 20.00 | 8.80 |
May | 0.314780E+10 | 19335.16 | 13-MAY-20:14 | 17.80 | 7.43 | 0.346556E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.558048E+10 | 20247.64 | 24-JUN-21:40 | 16.70 | 8.28 | 0.357142E+09 | 449.52 | 18-JUN-12:09 | 21.78 | 14.73 |
July | 0.744861E+10 | 19045.84 | 28-JUL-22:54 | 18.30 | 10.32 | 0.374863E+09 | 449.50 | 23-JUL-17:19 | 23.87 | 12.98 |
August | 0.717693E+10 | 20081.22 | 14-AUG-20:36 | 16.33 | 9.36 | 0.368602E+09 | 449.51 | 20-AUG-12:09 | 18.98 | 12.62 |
September | 0.549192E+10 | 20777.22 | 08-SEP-20:30 | 13.60 | 8.06 | 0.355240E+09 | 449.52 | 10-SEP-12:50 | 18.77 | 13.26 |
October | 0.352685E+10 | 19434.15 | 15-OCT-18:08 | 16.93 | 8.37 | 0.354312E+09 | 449.49 | 22-OCT-17:19 | 15.57 | 7.64 |
November | 0.168851E+10 | 18124.67 | 04-NOV-19:22 | 13.70 | 6.55 | 0.309658E+09 | 449.49 | 05-NOV-17:19 | 12.73 | 5.65 |
December | 0.735964E+09 | 7927.94 | 29-DEC-20:52 | -22.8 | -23.1 | 0.295446E+09 | 401.93 | 10-DEC-18:00 | 0.00 | -3.2 |
Annual Sum or Average | 0.391844E+11 | 0.395150E+10 | ||||||||
Minimum of Months | 0.456448E+09 | 3709.06 | -22.8 | -23.1 | 0.275068E+09 | 401.93 | 0.00 | -3.2 | ||
Maximum of Months | 0.744861E+10 | 20777.22 | 18.30 | 10.32 | 0.374863E+09 | 449.52 | 23.87 | 14.73 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.240460E+09 | 4039.03 | 21-JAN-18:43 | -4.8 | -6.4 | 0.169179E+09 | 345.31 | 14-JAN-13:20 | 10.20 | 4.86 |
February | 0.582119E+09 | 5277.46 | 01-FEB-19:23 | -10.6 | -12.3 | 0.158744E+09 | 420.06 | 25-FEB-13:00 | 15.00 | 5.03 |
March | 0.103597E+10 | 5393.53 | 01-MAR-08:61 | -9.3 | -10.0 | 0.177199E+09 | 365.46 | 18-MAR-12:00 | 11.70 | 3.92 |
April | 0.139947E+10 | 4007.83 | 28-APR-07:01 | -3.2 | -4.6 | 0.186295E+09 | 435.18 | 08-APR-12:30 | 12.80 | 6.12 |
May | 0.212642E+10 | 5098.60 | 20-MAY-16:00 | 30.00 | 15.19 | 0.204981E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.391693E+10 | 13028.76 | 26-JUN-06:02 | 13.03 | 10.63 | 0.220361E+09 | 449.50 | 03-JUN-12:00 | 23.90 | 14.38 |
July | 0.531498E+10 | 20426.10 | 27-JUL-06:02 | 13.40 | 10.16 | 0.224048E+09 | 449.50 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.520418E+10 | 19084.02 | 01-AUG-06:02 | 13.07 | 9.91 | 0.229339E+09 | 449.49 | 12-AUG-12:00 | 30.00 | 14.95 |
September | 0.390603E+10 | 19467.48 | 03-SEP-07:02 | 18.27 | 10.73 | 0.212011E+09 | 449.50 | 23-SEP-12:09 | 21.28 | 11.86 |
October | 0.262327E+10 | 7047.24 | 19-OCT-06:02 | 12.02 | 5.44 | 0.205622E+09 | 449.49 | 28-OCT-12:09 | 18.12 | 9.55 |
November | 0.132510E+10 | 4996.44 | 11-NOV-09:01 | -7.9 | -8.8 | 0.175953E+09 | 449.49 | 04-NOV-12:30 | 16.40 | 7.95 |
December | 0.475330E+09 | 3730.20 | 23-DEC-18:03 | -3.3 | -5.7 | 0.169190E+09 | 343.70 | 02-DEC-13:00 | 9.40 | 4.25 |
Annual Sum or Average | 0.281503E+11 | 0.233292E+10 | ||||||||
Minimum of Months | 0.240460E+09 | 3730.20 | -10.6 | -12.3 | 0.158744E+09 | 343.70 | 9.40 | 3.92 | ||
Maximum of Months | 0.531498E+10 | 20426.10 | 30.00 | 15.19 | 0.229339E+09 | 449.50 | 30.00 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.185353E+09 | 5232.83 | 19-JAN-11:13 | -10.4 | -11.1 | 0.169156E+09 | 341.26 | 14-JAN-13:20 | 10.20 | 4.86 |
February | 0.505827E+09 | 6020.54 | 02-FEB-18:32 | -13.9 | -14.4 | 0.158156E+09 | 415.47 | 25-FEB-13:00 | 15.00 | 5.03 |
March | 0.919053E+09 | 5816.76 | 03-MAR-11:42 | -12.9 | -13.8 | 0.176542E+09 | 362.23 | 18-MAR-12:00 | 11.70 | 3.92 |
April | 0.125781E+10 | 3891.76 | 27-APR-07:01 | -1.6 | -3.1 | 0.184855E+09 | 430.42 | 08-APR-12:30 | 12.80 | 6.12 |
May | 0.199736E+10 | 5040.71 | 20-MAY-16:00 | 30.00 | 15.19 | 0.204140E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.387430E+10 | 13539.45 | 26-JUN-06:02 | 13.03 | 10.63 | 0.220287E+09 | 449.50 | 03-JUN-12:00 | 23.90 | 14.38 |
July | 0.532845E+10 | 20539.63 | 27-JUL-06:02 | 13.40 | 10.16 | 0.224046E+09 | 449.50 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.520810E+10 | 19874.25 | 01-AUG-06:02 | 13.07 | 9.91 | 0.229315E+09 | 449.49 | 12-AUG-12:00 | 30.00 | 14.95 |
September | 0.385683E+10 | 19606.11 | 03-SEP-07:02 | 18.27 | 10.73 | 0.211687E+09 | 449.50 | 23-SEP-12:09 | 21.28 | 11.86 |
October | 0.248925E+10 | 5910.28 | 19-OCT-06:02 | 12.02 | 5.44 | 0.204658E+09 | 449.49 | 28-OCT-12:09 | 18.12 | 9.55 |
November | 0.120373E+10 | 6004.94 | 26-NOV-11:42 | -13.8 | -14.8 | 0.174477E+09 | 449.49 | 04-NOV-12:00 | 16.70 | 8.09 |
December | 0.397809E+09 | 4824.39 | 14-DEC-10:23 | -8.3 | -8.6 | 0.169112E+09 | 340.50 | 02-DEC-13:50 | 9.40 | 4.29 |
Annual Sum or Average | 0.272239E+11 | 0.232643E+10 | ||||||||
Minimum of Months | 0.185353E+09 | 3891.76 | -13.9 | -14.8 | 0.158156E+09 | 340.50 | 9.40 | 3.92 | ||
Maximum of Months | 0.532845E+10 | 20539.63 | 30.00 | 15.19 | 0.229315E+09 | 449.50 | 30.00 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.116932E+09 | 3598.68 | 20-JAN-10:33 | -2.6 | -5.2 | 0.169146E+09 | 340.06 | 14-JAN-13:09 | 10.40 | 5.00 |
February | 0.409001E+09 | 5248.32 | 01-FEB-18:33 | -10.4 | -12.0 | 0.157306E+09 | 406.55 | 25-FEB-13:00 | 15.00 | 5.03 |
March | 0.751282E+09 | 5233.23 | 01-MAR-08:61 | -9.3 | -10.0 | 0.175641E+09 | 356.64 | 18-MAR-12:00 | 11.70 | 3.92 |
April | 0.102307E+10 | 3808.68 | 27-APR-07:01 | -1.6 | -3.1 | 0.182384E+09 | 417.38 | 08-APR-12:30 | 12.80 | 6.12 |
May | 0.171715E+10 | 4799.54 | 20-MAY-16:00 | 30.00 | 15.19 | 0.202459E+09 | 449.50 | 13-MAY-12:09 | 23.40 | 10.96 |
June | 0.361664E+10 | 11381.68 | 26-JUN-06:02 | 13.03 | 10.63 | 0.219978E+09 | 449.50 | 03-JUN-12:00 | 23.90 | 14.38 |
July | 0.510602E+10 | 19142.64 | 27-JUL-06:02 | 13.40 | 10.16 | 0.224009E+09 | 449.50 | 01-JUL-12:00 | 26.70 | 16.71 |
August | 0.497663E+10 | 18772.29 | 09-AUG-06:02 | 15.83 | 11.03 | 0.229130E+09 | 449.49 | 12-AUG-12:00 | 30.00 | 14.95 |
September | 0.361685E+10 | 19293.32 | 03-SEP-07:02 | 18.27 | 10.73 | 0.210876E+09 | 449.50 | 23-SEP-12:09 | 21.28 | 11.86 |
October | 0.221772E+10 | 4756.54 | 18-OCT-14:00 | 25.00 | 11.37 | 0.202432E+09 | 449.49 | 28-OCT-12:09 | 18.12 | 9.55 |
November | 0.101895E+10 | 4323.12 | 10-NOV-08:61 | -4.6 | -5.5 | 0.172067E+09 | 449.44 | 04-NOV-12:00 | 16.70 | 8.09 |
December | 0.279709E+09 | 1958.69 | 06-DEC-18:10 | 5.32 | 1.45 | 0.169029E+09 | 340.06 | 09-DEC-13:09 | 3.95 | 0.92 |
Annual Sum or Average | 0.248499E+11 | 0.231446E+10 | ||||||||
Minimum of Months | 0.116932E+09 | 1958.69 | -10.4 | -12.0 | 0.157306E+09 | 340.06 | 3.95 | 0.92 | ||
Maximum of Months | 0.510602E+10 | 19293.32 | 30.00 | 15.19 | 0.229130E+09 | 449.50 | 30.00 | 16.71 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 39626790.57 | 6906.67 | 03-JAN-11:23 | 2.50 | -2.3 | 0.578269E+09 | 906.82 | 14-JAN-15:39 | 10.20 | 4.75 |
February | 0.489570E+09 | 4956.38 | 27-FEB-18:40 | 7.93 | 3.27 | 0.531652E+09 | 1007.66 | 25-FEB-15:50 | 15.00 | 5.15 |
March | 0.789025E+09 | 5816.46 | 11-MAR-18:33 | 5.17 | 0.65 | 0.596750E+09 | 908.66 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.153355E+10 | 4469.65 | 26-APR-17:30 | 9.15 | 4.23 | 0.597894E+09 | 1063.81 | 06-APR-16:10 | 22.02 | 10.90 |
May | 0.254271E+10 | 7765.16 | 20-MAY-16:00 | 30.00 | 15.19 | 0.667124E+09 | 1198.63 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.557514E+10 | 13844.18 | 26-JUN-07:03 | 17.67 | 12.35 | 0.745836E+09 | 1198.64 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.810893E+10 | 27865.60 | 27-JUL-07:02 | 13.98 | 10.40 | 0.765644E+09 | 1198.64 | 08-JUL-14:09 | 19.08 | 9.43 |
August | 0.792157E+10 | 29672.97 | 08-AUG-07:03 | 19.60 | 12.39 | 0.782329E+09 | 1198.71 | 05-AUG-14:09 | 34.40 | 17.14 |
September | 0.569389E+10 | 31336.30 | 05-SEP-07:02 | 18.98 | 12.61 | 0.709443E+09 | 1198.70 | 02-SEP-14:09 | 33.98 | 16.01 |
October | 0.356463E+10 | 8746.77 | 21-OCT-08:62 | -0.5 | -1.4 | 0.658283E+09 | 1198.63 | 28-OCT-14:30 | 19.45 | 9.56 |
November | 0.139374E+10 | 6264.59 | 22-NOV-10:33 | 4.10 | 0.27 | 0.565111E+09 | 1144.18 | 04-NOV-14:39 | 16.87 | 8.02 |
December | 0.147410E+09 | 9673.04 | 14-DEC-18:33 | -3.9 | -5.5 | 0.579249E+09 | 906.82 | 02-DEC-15:00 | 3.90 | 1.29 |
Annual Sum or Average | 0.377998E+11 | 0.777758E+10 | ||||||||
Minimum of Months | 39626790.57 | 4469.65 | -3.9 | -5.5 | 0.531652E+09 | 906.82 | 3.90 | 1.29 | ||
Maximum of Months | 0.810893E+10 | 31336.30 | 30.00 | 15.19 | 0.782329E+09 | 1198.71 | 34.40 | 17.14 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 17893221.74 | 4039.28 | 03-JAN-18:12 | -3.5 | -6.3 | 0.289122E+09 | 453.41 | 14-JAN-15:39 | 10.20 | 4.75 |
February | 0.186478E+09 | 4691.24 | 23-FEB-18:53 | -6.7 | -7.2 | 0.267076E+09 | 524.65 | 25-FEB-15:00 | 15.00 | 5.18 |
March | 0.333183E+09 | 3380.56 | 31-MAR-18:53 | -0.6 | -1.8 | 0.298855E+09 | 469.43 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.541488E+09 | 2444.67 | 20-APR-10:15 | 3.70 | 2.26 | 0.303425E+09 | 533.35 | 01-APR-14:00 | 18.30 | 6.98 |
May | 0.103485E+10 | 4026.84 | 20-MAY-16:00 | 30.00 | 15.19 | 0.338101E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.268133E+10 | 6209.94 | 26-JUN-07:03 | 17.67 | 12.35 | 0.375547E+09 | 599.32 | 17-JUN-14:09 | 18.98 | 10.18 |
July | 0.411144E+10 | 13225.00 | 17-JUL-07:02 | 23.17 | 14.92 | 0.383214E+09 | 599.32 | 01-JUL-14:00 | 24.40 | 16.22 |
August | 0.397464E+10 | 13139.65 | 08-AUG-07:03 | 19.60 | 12.39 | 0.392003E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.271279E+10 | 13607.43 | 05-SEP-07:02 | 18.98 | 12.61 | 0.358056E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.147810E+10 | 3997.77 | 18-OCT-14:40 | 25.00 | 11.51 | 0.335651E+09 | 599.32 | 28-OCT-14:09 | 19.08 | 9.41 |
November | 0.538811E+09 | 2457.67 | 06-NOV-11:40 | 5.27 | 1.51 | 0.285392E+09 | 595.09 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 62080754.49 | 4342.28 | 22-DEC-11:23 | -5.0 | -6.2 | 0.289626E+09 | 453.41 | 02-DEC-15:09 | 6.65 | 2.69 |
Annual Sum or Average | 0.176731E+11 | 0.391607E+10 | ||||||||
Minimum of Months | 17893221.74 | 2444.67 | -6.7 | -7.2 | 0.267076E+09 | 453.41 | 6.65 | 2.69 | ||
Maximum of Months | 0.411144E+10 | 13607.43 | 30.00 | 15.19 | 0.392003E+09 | 599.33 | 27.70 | 16.22 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 11945632.21 | 1986.35 | 17-JAN-11:25 | 6.10 | 1.61 | 0.289133E+09 | 453.41 | 14-JAN-15:00 | 10.00 | 4.55 |
February | 0.169903E+09 | 3271.65 | 15-FEB-19:03 | 0.00 | -1.8 | 0.266815E+09 | 521.37 | 25-FEB-15:00 | 15.00 | 5.18 |
March | 0.297021E+09 | 2208.13 | 16-MAR-15:25 | 5.00 | -1.1 | 0.298733E+09 | 466.50 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.505059E+09 | 2531.34 | 20-APR-10:55 | 3.30 | 2.03 | 0.302516E+09 | 531.90 | 06-APR-16:10 | 22.02 | 10.90 |
May | 0.979029E+09 | 3936.24 | 20-MAY-16:00 | 30.00 | 15.19 | 0.337316E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.260257E+10 | 5490.19 | 26-JUN-07:03 | 17.67 | 12.35 | 0.375224E+09 | 599.32 | 17-JUN-14:20 | 19.07 | 10.19 |
July | 0.403133E+10 | 13082.13 | 17-JUL-07:02 | 23.17 | 14.92 | 0.383179E+09 | 599.32 | 01-JUL-14:00 | 24.40 | 16.22 |
August | 0.389841E+10 | 13015.30 | 08-AUG-07:03 | 19.60 | 12.39 | 0.391930E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.265699E+10 | 13484.75 | 05-SEP-07:02 | 18.98 | 12.61 | 0.357691E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.144043E+10 | 3922.18 | 18-OCT-14:40 | 25.00 | 11.51 | 0.334864E+09 | 599.32 | 28-OCT-14:09 | 19.08 | 9.41 |
November | 0.508621E+09 | 2422.91 | 06-NOV-11:50 | 5.48 | 1.64 | 0.284932E+09 | 592.23 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 52436060.61 | 4481.81 | 16-DEC-11:53 | -5.6 | -6.4 | 0.289625E+09 | 453.41 | 09-DEC-15:00 | 10.60 | 3.83 |
Annual Sum or Average | 0.171537E+11 | 0.391196E+10 | ||||||||
Minimum of Months | 11945632.21 | 1986.35 | -5.6 | -6.4 | 0.266815E+09 | 453.41 | 10.00 | 3.83 | ||
Maximum of Months | 0.403133E+10 | 13484.75 | 30.00 | 15.19 | 0.391930E+09 | 599.33 | 27.70 | 16.22 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 4325541.14 | 914.51 | 14-JAN-12:00 | 10.00 | 4.77 | 0.289134E+09 | 453.41 | 14-JAN-15:09 | 10.50 | 5.05 |
February | 0.122638E+09 | 1922.01 | 27-FEB-18:50 | 7.57 | 3.05 | 0.266035E+09 | 509.86 | 25-FEB-15:00 | 15.00 | 5.18 |
March | 0.202513E+09 | 3108.63 | 01-MAR-10:13 | 0.93 | -0.8 | 0.298466E+09 | 458.15 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.377928E+09 | 3789.14 | 27-APR-10:43 | -2.5 | -3.7 | 0.299802E+09 | 531.90 | 06-APR-16:10 | 22.02 | 10.90 |
May | 0.802813E+09 | 3697.65 | 20-MAY-16:00 | 30.00 | 15.19 | 0.334627E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.236145E+10 | 5008.72 | 23-JUN-14:10 | 31.13 | 15.20 | 0.373688E+09 | 599.33 | 17-JUN-14:50 | 19.32 | 10.21 |
July | 0.383968E+10 | 12853.55 | 17-JUL-07:02 | 23.17 | 14.92 | 0.383017E+09 | 599.32 | 01-JUL-14:00 | 24.40 | 16.22 |
August | 0.371226E+10 | 12848.24 | 07-AUG-07:02 | 22.77 | 12.36 | 0.391596E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.248729E+10 | 13321.69 | 05-SEP-07:02 | 18.98 | 12.61 | 0.356246E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.128397E+10 | 3682.39 | 18-OCT-14:40 | 25.00 | 11.51 | 0.331696E+09 | 599.32 | 28-OCT-14:09 | 19.08 | 9.41 |
November | 0.411262E+09 | 3601.69 | 13-NOV-19:33 | -1.6 | -5.2 | 0.283596E+09 | 582.13 | 04-NOV-14:00 | 16.70 | 7.95 |
December | 26719035.08 | 3380.04 | 20-DEC-19:03 | -0.5 | -3.2 | 0.289624E+09 | 453.41 | 09-DEC-15:00 | 10.60 | 3.83 |
Annual Sum or Average | 0.156328E+11 | 0.389753E+10 | ||||||||
Minimum of Months | 4325541.14 | 914.51 | -2.5 | -5.2 | 0.266035E+09 | 453.41 | 10.50 | 3.83 | ||
Maximum of Months | 0.383968E+10 | 13321.69 | 31.13 | 15.20 | 0.391596E+09 | 599.33 | 27.70 | 16.22 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 358085.67 | 295.54 | 14-JAN-12:00 | 10.00 | 4.77 | 0.289135E+09 | 453.41 | 14-JAN-15:09 | 10.50 | 5.05 |
February | 37717298.95 | 1179.87 | 27-FEB-18:10 | 9.03 | 3.92 | 0.264966E+09 | 486.69 | 25-FEB-15:00 | 15.00 | 5.18 |
March | 26578328.15 | 2601.00 | 16-MAR-17:33 | 2.77 | -2.3 | 0.298199E+09 | 453.41 | 18-MAR-14:00 | 12.20 | 4.15 |
April | 0.113532E+09 | 1416.74 | 13-APR-19:35 | 8.53 | 4.51 | 0.295409E+09 | 531.91 | 06-APR-16:49 | 21.28 | 10.52 |
May | 0.439588E+09 | 3342.13 | 20-MAY-16:00 | 30.00 | 15.19 | 0.330063E+09 | 599.32 | 27-MAY-14:00 | 23.30 | 12.28 |
June | 0.193739E+10 | 4902.75 | 23-JUN-14:10 | 31.13 | 15.20 | 0.370071E+09 | 599.32 | 03-JUN-14:09 | 24.18 | 14.31 |
July | 0.362610E+10 | 14129.01 | 17-JUL-07:02 | 23.17 | 14.92 | 0.382480E+09 | 599.33 | 01-JUL-14:00 | 24.40 | 16.22 |
August | 0.346953E+10 | 13302.48 | 07-AUG-07:02 | 22.77 | 12.36 | 0.390787E+09 | 599.32 | 19-AUG-14:09 | 21.28 | 11.33 |
September | 0.218045E+10 | 16843.78 | 05-SEP-07:02 | 18.98 | 12.61 | 0.353769E+09 | 599.33 | 09-SEP-14:09 | 27.70 | 13.65 |
October | 0.921979E+09 | 3375.61 | 18-OCT-14:40 | 25.00 | 11.51 | 0.326793E+09 | 599.32 | 28-OCT-14:39 | 19.63 | 9.63 |
November | 0.185842E+09 | 2245.08 | 15-NOV-18:35 | 4.07 | -0.6 | 0.281912E+09 | 567.58 | 04-NOV-14:50 | 16.78 | 7.98 |
December | 854906.03 | 307.82 | 07-DEC-12:00 | 7.80 | 3.02 | 0.289624E+09 | 453.41 | 09-DEC-15:50 | 10.13 | 3.72 |
Annual Sum or Average | 0.129399E+11 | 0.387321E+10 | ||||||||
Minimum of Months | 358085.67 | 295.54 | 2.77 | -2.3 | 0.264966E+09 | 453.41 | 10.13 | 3.72 | ||
Maximum of Months | 0.362610E+10 | 16843.78 | 31.13 | 15.20 | 0.390787E+09 | 599.33 | 27.70 | 16.22 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.843014E+10 | 58974.64 | 27-JAN-08:12 | -27.2 |
February | 0.405667E+10 | 58781.24 | 05-FEB-08:61 | -20.1 |
March | 0.285631E+10 | 58766.79 | 04-MAR-08:61 | -19.9 |
April | 0.920893E+09 | 58718.57 | 22-APR-07:01 | 2.85 |
May | 0.531184E+09 | 58699.28 | 01-MAY-07:01 | 0.78 |
June | 47415025.48 | 4250.58 | 17-JUN-07:02 | 8.77 |
July | 25632837.40 | 1488.73 | 18-JUL-07:05 | 24.27 |
August | 27133085.84 | 1432.26 | 07-AUG-07:04 | 22.77 |
September | 61370134.52 | 48976.78 | 20-SEP-07:01 | 4.78 |
October | 0.186721E+09 | 58708.24 | 10-OCT-07:01 | -5.7 |
November | 0.150766E+10 | 58740.58 | 21-NOV-08:61 | -8.0 |
December | 0.491442E+10 | 58780.66 | 29-DEC-08:61 | -27.9 |
Annual Sum or Average | 0.235656E+11 | |||
Minimum of Months | 25632837.40 | 1432.26 | -27.9 | |
Maximum of Months | 0.843014E+10 | 58974.64 | 24.27 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.315353E+10 | 31592.46 | 08-JAN-08:61 | -27.2 |
February | 0.134827E+10 | 31589.68 | 05-FEB-08:61 | -20.1 |
March | 0.793657E+09 | 31578.38 | 04-MAR-08:61 | -19.9 |
April | 0.207891E+09 | 31547.13 | 29-APR-07:01 | -4.5 |
May | 0.141388E+09 | 31538.07 | 08-MAY-07:01 | -2.1 |
June | 26098010.89 | 1557.26 | 22-JUN-07:07 | 19.37 |
July | 21074665.60 | 1772.27 | 26-JUL-07:05 | 23.68 |
August | 23104497.44 | 1754.86 | 08-AUG-07:05 | 19.60 |
September | 48399366.03 | 1759.57 | 04-SEP-07:04 | 20.02 |
October | 89657096.77 | 13744.47 | 10-OCT-07:01 | -5.7 |
November | 0.496389E+09 | 31561.54 | 27-NOV-08:61 | -12.7 |
December | 0.172392E+10 | 31586.38 | 29-DEC-08:61 | -27.9 |
Annual Sum or Average | 0.807338E+10 | |||
Minimum of Months | 21074665.60 | 1557.26 | -27.9 | |
Maximum of Months | 0.315353E+10 | 31592.46 | 23.68 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.362086E+10 | 31384.06 | 08-JAN-08:61 | -27.2 |
February | 0.163635E+10 | 31384.02 | 05-FEB-08:61 | -20.1 |
March | 0.102622E+10 | 31356.81 | 05-MAR-08:61 | -18.1 |
April | 0.266694E+09 | 30901.24 | 30-APR-07:01 | -3.2 |
May | 0.215249E+09 | 31045.57 | 08-MAY-06:01 | -2.7 |
June | 54086100.39 | 1647.58 | 22-JUN-06:05 | 16.57 |
July | 98202585.55 | 2774.49 | 17-JUL-19:02 | 33.48 |
August | 80668375.94 | 3155.53 | 06-AUG-16:02 | 35.50 |
September | 76604433.39 | 2859.56 | 02-SEP-17:02 | 34.03 |
October | 0.105033E+09 | 16189.95 | 10-OCT-06:02 | -6.1 |
November | 0.667491E+09 | 31332.96 | 27-NOV-07:01 | -13.5 |
December | 0.212596E+10 | 31362.13 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.997342E+10 | |||
Minimum of Months | 54086100.39 | 1647.58 | -27.6 | |
Maximum of Months | 0.362086E+10 | 31384.06 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.384431E+10 | 31872.66 | 08-JAN-08:61 | -27.2 |
February | 0.177508E+10 | 31873.08 | 05-FEB-08:61 | -20.1 |
March | 0.114806E+10 | 31845.18 | 05-MAR-08:61 | -18.1 |
April | 0.308187E+09 | 31380.89 | 30-APR-07:01 | -3.2 |
May | 0.250750E+09 | 31529.49 | 08-MAY-06:01 | -2.7 |
June | 56369215.14 | 1650.23 | 22-JUN-06:05 | 16.57 |
July | 98294160.22 | 2775.37 | 17-JUL-19:02 | 33.48 |
August | 80477215.49 | 3156.83 | 06-AUG-16:02 | 35.50 |
September | 80284419.98 | 2861.72 | 02-SEP-17:02 | 34.03 |
October | 0.128407E+09 | 22062.82 | 10-OCT-06:02 | -6.1 |
November | 0.758579E+09 | 31822.25 | 27-NOV-07:01 | -13.5 |
December | 0.230911E+10 | 31850.83 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.108379E+11 | |||
Minimum of Months | 56369215.14 | 1650.23 | -27.6 | |
Maximum of Months | 0.384431E+10 | 31873.08 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.419722E+10 | 31155.84 | 08-JAN-08:61 | -27.2 |
February | 0.201731E+10 | 31156.38 | 05-FEB-08:61 | -20.1 |
March | 0.135609E+10 | 31129.45 | 05-MAR-08:61 | -18.1 |
April | 0.394405E+09 | 30681.33 | 30-APR-07:01 | -3.2 |
May | 0.303737E+09 | 30824.52 | 08-MAY-06:01 | -2.7 |
June | 62086325.00 | 1555.28 | 24-JUN-17:12 | 27.23 |
July | 97763067.18 | 2774.79 | 17-JUL-19:02 | 33.48 |
August | 81524985.74 | 3156.78 | 06-AUG-16:02 | 35.50 |
September | 86612328.15 | 3087.12 | 20-SEP-06:05 | 3.48 |
October | 0.159440E+09 | 26889.96 | 10-OCT-06:02 | -6.1 |
November | 0.889841E+09 | 31107.13 | 27-NOV-07:01 | -13.5 |
December | 0.258308E+10 | 31134.96 | 31-DEC-08:61 | -27.6 |
Annual Sum or Average | 0.122291E+11 | |||
Minimum of Months | 62086325.00 | 1555.28 | -27.6 | |
Maximum of Months | 0.419722E+10 | 31156.38 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.886494E+10 | 57563.87 | 08-JAN-09:12 | -27.0 |
February | 0.442851E+10 | 57367.59 | 04-FEB-08:61 | -20.0 |
March | 0.309238E+10 | 57492.34 | 06-MAR-08:12 | -15.5 |
April | 0.105597E+10 | 57303.82 | 22-APR-07:01 | 2.85 |
May | 0.676348E+09 | 57295.42 | 08-MAY-07:01 | -2.1 |
June | 54413068.24 | 1960.20 | 24-JUN-17:03 | 27.52 |
July | 68039309.99 | 4277.23 | 16-JUL-16:02 | 32.88 |
August | 63589305.21 | 5337.36 | 06-AUG-16:02 | 35.50 |
September | 0.106254E+09 | 49526.26 | 20-SEP-07:01 | 4.78 |
October | 0.306377E+09 | 57312.92 | 10-OCT-07:01 | -5.7 |
November | 0.207368E+10 | 57335.29 | 27-NOV-08:61 | -12.7 |
December | 0.567596E+10 | 57365.64 | 31-DEC-09:01 | -26.2 |
Annual Sum or Average | 0.264665E+11 | |||
Minimum of Months | 54413068.24 | 1960.20 | -27.0 | |
Maximum of Months | 0.886494E+10 | 57563.87 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.494742E+10 | 28867.21 | 08-JAN-09:12 | -27.0 |
February | 0.253027E+10 | 28681.14 | 04-FEB-08:61 | -20.0 |
March | 0.181919E+10 | 28816.84 | 06-MAR-08:12 | -15.5 |
April | 0.664553E+09 | 28645.84 | 29-APR-07:01 | -4.5 |
May | 0.453001E+09 | 28642.45 | 08-MAY-07:01 | -2.1 |
June | 60533741.58 | 1473.73 | 24-JUN-17:12 | 27.23 |
July | 57394097.53 | 2612.19 | 16-JUL-16:02 | 32.88 |
August | 53151562.41 | 3123.87 | 06-AUG-16:02 | 35.50 |
September | 93682385.40 | 25233.08 | 20-SEP-07:01 | 4.78 |
October | 0.227946E+09 | 28651.64 | 10-OCT-07:01 | -5.7 |
November | 0.121558E+10 | 28663.42 | 27-NOV-08:61 | -12.7 |
December | 0.322710E+10 | 28692.71 | 31-DEC-09:13 | -25.8 |
Annual Sum or Average | 0.153498E+11 | |||
Minimum of Months | 53151562.41 | 1473.73 | -27.0 | |
Maximum of Months | 0.494742E+10 | 28867.21 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.502639E+10 | 29221.14 | 08-JAN-09:12 | -27.0 |
February | 0.259549E+10 | 29046.09 | 04-FEB-08:61 | -20.0 |
March | 0.188799E+10 | 29183.37 | 06-MAR-08:12 | -15.5 |
April | 0.714486E+09 | 29010.79 | 29-APR-07:01 | -4.5 |
May | 0.478614E+09 | 29007.37 | 08-MAY-07:01 | -2.1 |
June | 64424292.69 | 1467.55 | 24-JUN-17:12 | 27.23 |
July | 57600065.19 | 2608.69 | 16-JUL-16:02 | 32.88 |
August | 53716929.48 | 3120.89 | 06-AUG-16:02 | 35.50 |
September | 96040886.47 | 26956.19 | 20-SEP-07:01 | 4.78 |
October | 0.239814E+09 | 29016.60 | 10-OCT-07:01 | -5.7 |
November | 0.126201E+10 | 29028.38 | 27-NOV-08:61 | -12.7 |
December | 0.330735E+10 | 29056.74 | 31-DEC-09:13 | -25.8 |
Annual Sum or Average | 0.157839E+11 | |||
Minimum of Months | 53716929.48 | 1467.55 | -27.0 | |
Maximum of Months | 0.502639E+10 | 29221.14 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.542755E+10 | 29010.41 | 08-JAN-09:12 | -27.0 |
February | 0.290785E+10 | 28848.42 | 05-FEB-09:01 | -20.4 |
March | 0.221331E+10 | 28980.56 | 06-MAR-08:12 | -15.5 |
April | 0.925436E+09 | 28778.60 | 22-APR-07:01 | 2.85 |
May | 0.601760E+09 | 28774.59 | 08-MAY-07:01 | -2.1 |
June | 75890095.73 | 6889.70 | 17-JUN-07:02 | 8.77 |
July | 61475291.00 | 2605.68 | 16-JUL-16:02 | 32.88 |
August | 61367741.83 | 3118.38 | 06-AUG-16:02 | 35.50 |
September | 0.109480E+09 | 28554.55 | 20-SEP-07:01 | 4.78 |
October | 0.280741E+09 | 28781.62 | 10-OCT-07:01 | -5.7 |
November | 0.145429E+10 | 28793.49 | 27-NOV-08:61 | -12.7 |
December | 0.366360E+10 | 28854.12 | 31-DEC-09:13 | -25.8 |
Annual Sum or Average | 0.177828E+11 | |||
Minimum of Months | 61367741.83 | 2605.68 | -27.0 | |
Maximum of Months | 0.542755E+10 | 29010.41 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.792350E+10 | 31141.49 | 08-JAN-09:12 | -27.0 |
February | 0.453026E+10 | 30924.66 | 04-FEB-08:13 | -20.0 |
March | 0.385040E+10 | 31072.13 | 06-MAR-08:12 | -15.5 |
April | 0.189914E+10 | 30771.77 | 22-APR-07:01 | 2.85 |
May | 0.116566E+10 | 30765.02 | 01-MAY-07:01 | 0.78 |
June | 0.128314E+09 | 26117.06 | 17-JUN-07:02 | 8.77 |
July | 82642403.67 | 2673.65 | 16-JUL-16:02 | 32.88 |
August | 92411772.18 | 7251.12 | 18-AUG-07:03 | 10.37 |
September | 0.206545E+09 | 30492.68 | 20-SEP-07:01 | 4.78 |
October | 0.503776E+09 | 30767.94 | 10-OCT-07:01 | -5.7 |
November | 0.229876E+10 | 30830.87 | 27-NOV-08:13 | -12.5 |
December | 0.538270E+10 | 30954.38 | 31-DEC-09:13 | -25.8 |
Annual Sum or Average | 0.280641E+11 | |||
Minimum of Months | 82642403.67 | 2673.65 | -27.0 | |
Maximum of Months | 0.792350E+10 | 31141.49 | 32.88 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.900155E+10 | 5587.06 | 01-JAN-10:09 | 0.222596E+10 | 1343.25 | 01-JAN-10:09 |
February | 0.814396E+10 | 5587.06 | 01-FEB-10:09 | 0.201408E+10 | 1343.25 | 01-FEB-10:09 |
March | 0.901902E+10 | 5587.06 | 01-MAR-10:09 | 0.223053E+10 | 1343.25 | 01-MAR-10:09 |
April | 0.873329E+10 | 5587.06 | 01-APR-09:09 | 0.215990E+10 | 1343.25 | 01-APR-09:09 |
May | 0.900155E+10 | 5587.06 | 01-MAY-09:09 | 0.222596E+10 | 1343.25 | 01-MAY-09:09 |
June | 0.873302E+10 | 5587.06 | 01-JUN-09:09 | 0.215990E+10 | 1343.25 | 01-JUN-09:09 |
July | 0.901915E+10 | 5587.06 | 01-JUL-09:09 | 0.223053E+10 | 1343.25 | 01-JUL-09:09 |
August | 0.900155E+10 | 5587.06 | 01-AUG-09:09 | 0.222596E+10 | 1343.25 | 01-AUG-09:09 |
September | 0.875049E+10 | 5587.06 | 01-SEP-09:09 | 0.216447E+10 | 1343.25 | 01-SEP-09:09 |
October | 0.900168E+10 | 5587.06 | 01-OCT-09:09 | 0.222596E+10 | 1343.25 | 01-OCT-09:09 |
November | 0.869809E+10 | 5587.06 | 01-NOV-09:09 | 0.215077E+10 | 1343.25 | 01-NOV-09:09 |
December | 0.903649E+10 | 5587.06 | 01-DEC-10:09 | 0.223509E+10 | 1343.25 | 01-DEC-10:09 |
Annual Sum or Average | 0.106140E+12 | 0.262491E+11 | ||||
Minimum of Months | 0.814396E+10 | 5587.06 | 0.201408E+10 | 1343.25 | ||
Maximum of Months | 0.903649E+10 | 5587.06 | 0.223509E+10 | 1343.25 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.525997E+10 | 3268.27 | 01-JAN-10:09 | 0.111298E+10 | 671.63 | 01-JAN-10:09 |
February | 0.475885E+10 | 3268.27 | 01-FEB-10:09 | 0.100704E+10 | 671.63 | 01-FEB-10:09 |
March | 0.527019E+10 | 3268.27 | 01-MAR-10:09 | 0.111526E+10 | 671.63 | 01-MAR-10:09 |
April | 0.510323E+10 | 3268.27 | 01-APR-09:09 | 0.107995E+10 | 671.63 | 01-APR-09:09 |
May | 0.525997E+10 | 3268.27 | 01-MAY-09:09 | 0.111298E+10 | 671.63 | 01-MAY-09:09 |
June | 0.510306E+10 | 3268.27 | 01-JUN-09:09 | 0.107995E+10 | 671.63 | 01-JUN-09:09 |
July | 0.527027E+10 | 3268.27 | 01-JUL-09:09 | 0.111526E+10 | 671.63 | 01-JUL-09:09 |
August | 0.525997E+10 | 3268.27 | 01-AUG-09:09 | 0.111298E+10 | 671.63 | 01-AUG-09:09 |
September | 0.511328E+10 | 3268.27 | 01-SEP-09:09 | 0.108223E+10 | 671.63 | 01-SEP-09:09 |
October | 0.526005E+10 | 3268.27 | 01-OCT-09:09 | 0.111298E+10 | 671.63 | 01-OCT-09:09 |
November | 0.508263E+10 | 3268.27 | 01-NOV-09:09 | 0.107538E+10 | 671.63 | 01-NOV-09:09 |
December | 0.528040E+10 | 3268.27 | 01-DEC-10:09 | 0.111755E+10 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.620219E+11 | 0.131245E+11 | ||||
Minimum of Months | 0.475885E+10 | 3268.27 | 0.100704E+10 | 671.63 | ||
Maximum of Months | 0.528040E+10 | 3268.27 | 0.111755E+10 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.372206E+10 | 3006.97 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.337152E+10 | 3006.97 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.380758E+10 | 3006.97 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.361234E+10 | 3006.97 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.376482E+10 | 3006.97 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.367648E+10 | 3006.97 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.370068E+10 | 3006.97 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.380758E+10 | 3006.97 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.361234E+10 | 3006.97 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.372206E+10 | 3006.97 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.361234E+10 | 3006.97 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.370068E+10 | 3006.97 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.441105E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.337152E+10 | 3006.97 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.380758E+10 | 3006.97 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.372206E+10 | 3006.97 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.337152E+10 | 3006.97 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.380758E+10 | 3006.97 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.361234E+10 | 3006.97 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.376482E+10 | 3006.97 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.367648E+10 | 3006.97 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.370068E+10 | 3006.97 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.380758E+10 | 3006.97 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.361234E+10 | 3006.97 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.372206E+10 | 3006.97 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.361234E+10 | 3006.97 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.370068E+10 | 3006.97 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.441105E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.337152E+10 | 3006.97 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.380758E+10 | 3006.97 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.372206E+10 | 3006.97 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.337152E+10 | 3006.97 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.380758E+10 | 3006.97 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.361234E+10 | 3006.97 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.376482E+10 | 3006.97 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.367648E+10 | 3006.97 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.370068E+10 | 3006.97 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.380758E+10 | 3006.97 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.361234E+10 | 3006.97 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.372206E+10 | 3006.97 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.361234E+10 | 3006.97 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.370068E+10 | 3006.97 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.441105E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.337152E+10 | 3006.97 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.380758E+10 | 3006.97 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.422804E+10 | 3712.57 | 01-JAN-11:09 | 0.161799E+10 | 1343.25 | 01-JAN-11:09 |
February | 0.383070E+10 | 3712.57 | 01-FEB-10:09 | 0.146554E+10 | 1343.25 | 01-FEB-10:09 |
March | 0.433280E+10 | 3712.57 | 01-MAR-10:09 | 0.165455E+10 | 1343.25 | 01-MAR-10:09 |
April | 0.410432E+10 | 3712.57 | 01-APR-09:09 | 0.157022E+10 | 1343.25 | 01-APR-09:09 |
May | 0.428042E+10 | 3712.57 | 01-MAY-09:09 | 0.163627E+10 | 1343.25 | 01-MAY-09:09 |
June | 0.418290E+10 | 3712.57 | 01-JUN-09:09 | 0.159764E+10 | 1343.25 | 01-JUN-09:09 |
July | 0.420185E+10 | 3712.57 | 01-JUL-09:09 | 0.160885E+10 | 1343.25 | 01-JUL-09:09 |
August | 0.433280E+10 | 3712.57 | 01-AUG-09:09 | 0.165455E+10 | 1343.25 | 01-AUG-09:09 |
September | 0.410432E+10 | 3712.57 | 01-SEP-09:09 | 0.157022E+10 | 1343.25 | 01-SEP-09:09 |
October | 0.422804E+10 | 3712.57 | 01-OCT-10:09 | 0.161799E+10 | 1343.25 | 01-OCT-10:09 |
November | 0.410432E+10 | 3712.57 | 01-NOV-09:09 | 0.157022E+10 | 1343.25 | 01-NOV-09:09 |
December | 0.420185E+10 | 3712.57 | 01-DEC-10:09 | 0.160885E+10 | 1343.25 | 01-DEC-10:09 |
Annual Sum or Average | 0.501324E+11 | 0.191729E+11 | ||||
Minimum of Months | 0.383070E+10 | 3712.57 | 0.146554E+10 | 1343.25 | ||
Maximum of Months | 0.433280E+10 | 3712.57 | 0.165455E+10 | 1343.25 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.900155E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.821744E+10 |
February | 0.163016E+10 | 0.814396E+10 | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.547979E+10 |
March | 0.178954E+10 | 0.901902E+10 | 0.223053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.503549E+10 |
April | 0.174484E+10 | 0.873329E+10 | 0.215990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.316103E+10 |
May | 0.179537E+10 | 0.900155E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40073531.63 | 0.276386E+10 |
June | 0.173447E+10 | 0.873302E+10 | 0.215990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249775E+09 | 0.125895E+10 |
July | 0.181028E+10 | 0.901915E+10 | 0.223053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.677627E+09 | 0.605262E+09 |
August | 0.178501E+10 | 0.900155E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.518201E+09 | 0.877119E+09 |
September | 0.174937E+10 | 0.875049E+10 | 0.216447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237866E+09 | 0.182892E+10 |
October | 0.180574E+10 | 0.900168E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2821189.41 | 0.305823E+10 |
November | 0.174613E+10 | 0.869809E+10 | 0.215077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.461860E+10 |
December | 0.181481E+10 | 0.903649E+10 | 0.223509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.657783E+10 |
Annual Sum or Average | 0.212115E+11 | 0.106140E+12 | 0.262491E+11 | 0.172636E+10 | 0.434825E+11 | ||||
Minimum of Months | 0.163016E+10 | 0.814396E+10 | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.605262E+09 |
Maximum of Months | 0.181481E+10 | 0.903649E+10 | 0.223509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.677627E+09 | 0.821744E+10 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.525997E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401663E+10 |
February | 0.815075E+09 | 0.475885E+10 | 0.100704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266846E+10 |
March | 0.894769E+09 | 0.527019E+10 | 0.111526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.245989E+10 |
April | 0.872416E+09 | 0.510323E+10 | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158669E+10 |
May | 0.897684E+09 | 0.525997E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 21453297.65 | 0.132751E+10 |
June | 0.867232E+09 | 0.510306E+10 | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134778E+09 | 0.560890E+09 |
July | 0.905135E+09 | 0.527027E+10 | 0.111526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366023E+09 | 0.240132E+09 |
August | 0.892501E+09 | 0.525997E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279253E+09 | 0.377180E+09 |
September | 0.874683E+09 | 0.511328E+10 | 0.108223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128207E+09 | 0.841216E+09 |
October | 0.902868E+09 | 0.526005E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1515574.68 | 0.149297E+10 |
November | 0.873064E+09 | 0.508263E+10 | 0.107538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226242E+10 |
December | 0.907403E+09 | 0.528040E+10 | 0.111755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.321974E+10 |
Annual Sum or Average | 0.106057E+11 | 0.620219E+11 | 0.131245E+11 | 0.931229E+09 | 0.210537E+11 | ||||
Minimum of Months | 0.815075E+09 | 0.475885E+10 | 0.100704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240132E+09 |
Maximum of Months | 0.907403E+09 | 0.528040E+10 | 0.111755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366023E+09 | 0.401663E+10 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411880E+10 |
February | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274586E+10 |
March | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252441E+10 |
April | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162851E+10 |
May | 0.544247E+09 | 0.376482E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21302760.77 | 0.136878E+10 |
June | 0.532585E+09 | 0.367648E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133365E+09 | 0.595659E+09 |
July | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.357971E+09 | 0.270258E+09 |
August | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276055E+09 | 0.404791E+09 |
September | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122642E+09 | 0.879687E+09 |
October | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1515543.58 | 0.153671E+10 |
November | 0.518979E+09 | 0.361234E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231782E+10 |
December | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331205E+10 |
Annual Sum or Average | 0.638324E+10 | 0.441105E+11 | 0.104207E+11 | 0.912851E+09 | 0.217033E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.270258E+09 |
Maximum of Months | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.357971E+09 | 0.411880E+10 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411189E+10 |
February | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273570E+10 |
March | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251566E+10 |
April | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161519E+10 |
May | 0.544247E+09 | 0.376482E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21303218.68 | 0.136025E+10 |
June | 0.532585E+09 | 0.367648E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133368E+09 | 0.594606E+09 |
July | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.357898E+09 | 0.270508E+09 |
August | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.275997E+09 | 0.404642E+09 |
September | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122566E+09 | 0.876309E+09 |
October | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1515543.31 | 0.152680E+10 |
November | 0.518979E+09 | 0.361234E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230211E+10 |
December | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330515E+10 |
Annual Sum or Average | 0.638324E+10 | 0.441105E+11 | 0.104207E+11 | 0.912648E+09 | 0.216188E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.270508E+09 |
Maximum of Months | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.357898E+09 | 0.411189E+10 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.410628E+10 |
February | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.272456E+10 |
March | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250599E+10 |
April | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159499E+10 |
May | 0.544247E+09 | 0.376482E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21305796.77 | 0.134566E+10 |
June | 0.532585E+09 | 0.367648E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133378E+09 | 0.590231E+09 |
July | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.358122E+09 | 0.268212E+09 |
August | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276080E+09 | 0.401453E+09 |
September | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.122668E+09 | 0.868049E+09 |
October | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1515544.19 | 0.150810E+10 |
November | 0.518979E+09 | 0.361234E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228084E+10 |
December | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.329933E+10 |
Annual Sum or Average | 0.638324E+10 | 0.441105E+11 | 0.104207E+11 | 0.913069E+09 | 0.214937E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268212E+09 |
Maximum of Months | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.358122E+09 | 0.410628E+10 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.422804E+10 | 0.161799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.755482E+10 |
February | 0.167188E+10 | 0.383070E+10 | 0.146554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.499682E+10 |
March | 0.189386E+10 | 0.433280E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.460461E+10 |
April | 0.180380E+10 | 0.410432E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.284884E+10 |
May | 0.186509E+10 | 0.428042E+10 | 0.163627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38434494.29 | 0.242283E+10 |
June | 0.182945E+10 | 0.418290E+10 | 0.159764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240583E+09 | 0.108427E+10 |
July | 0.183943E+10 | 0.420185E+10 | 0.160885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.647521E+09 | 0.507673E+09 |
August | 0.189386E+10 | 0.433280E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.498448E+09 | 0.749033E+09 |
September | 0.180380E+10 | 0.410432E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221995E+09 | 0.158298E+10 |
October | 0.183632E+10 | 0.422804E+10 | 0.161799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2730540.68 | 0.269172E+10 |
November | 0.176881E+10 | 0.410432E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.414747E+10 |
December | 0.183943E+10 | 0.420185E+10 | 0.160885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.607061E+10 |
Annual Sum or Average | 0.218821E+11 | 0.501324E+11 | 0.191729E+11 | 0.164971E+10 | 0.392617E+11 | ||||
Minimum of Months | 0.167188E+10 | 0.383070E+10 | 0.146554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.507673E+09 |
Maximum of Months | 0.189386E+10 | 0.433280E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.647521E+09 | 0.755482E+10 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.412703E+10 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.272579E+10 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251001E+10 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156381E+10 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21319439.18 | 0.132622E+10 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133569E+09 | 0.588677E+09 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359372E+09 | 0.268228E+09 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276710E+09 | 0.402059E+09 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123092E+09 | 0.861933E+09 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1515744.53 | 0.148087E+10 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226435E+10 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331431E+10 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.915579E+09 | 0.214333E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268228E+09 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359372E+09 | 0.412703E+10 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.412568E+10 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.272306E+10 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250808E+10 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155891E+10 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21320652.03 | 0.132163E+10 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133592E+09 | 0.586559E+09 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359456E+09 | 0.267333E+09 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276746E+09 | 0.401090E+09 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123133E+09 | 0.859724E+09 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1515745.48 | 0.147678E+10 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226102E+10 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.331271E+10 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.915764E+09 | 0.214026E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.267333E+09 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359456E+09 | 0.412568E+10 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411895E+10 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271257E+10 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250081E+10 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.154283E+10 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21323753.71 | 0.130488E+10 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133682E+09 | 0.577417E+09 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359671E+09 | 0.264183E+09 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276817E+09 | 0.397406E+09 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123214E+09 | 0.850758E+09 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1515739.81 | 0.146009E+10 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224958E+10 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330569E+10 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.916224E+09 | 0.212852E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.264183E+09 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.359671E+09 | 0.411895E+10 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.516264E+10 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.346697E+10 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318983E+10 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197440E+10 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22705701.89 | 0.173616E+10 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141078E+09 | 0.828058E+09 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379658E+09 | 0.436504E+09 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.293006E+09 | 0.600548E+09 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130173E+09 | 0.121148E+10 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1606593.31 | 0.193940E+10 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.292454E+10 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.414342E+10 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.968227E+09 | 0.276139E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.436504E+09 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379658E+09 | 0.516264E+10 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 5587.06 | 01-JAN-10:09 | 1343.25 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 15364.08 | 10-JAN-18:00 |
February | 2159.72 | 03-FEB-13:09 | 5587.06 | 01-FEB-10:09 | 1343.25 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 12414.04 | 09-FEB-18:00 |
March | 2159.72 | 03-MAR-13:09 | 5587.06 | 01-MAR-10:09 | 1343.25 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 11849.64 | 04-MAR-18:00 |
April | 2159.72 | 01-APR-12:09 | 5587.06 | 01-APR-09:09 | 1343.25 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 7152.78 | 27-APR-11:10 |
May | 2159.72 | 05-MAY-12:09 | 5587.06 | 01-MAY-09:09 | 1343.25 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1606.61 | 20-MAY-16:00 | 6558.06 | 22-MAY-16:00 |
June | 2159.72 | 02-JUN-12:09 | 5587.06 | 01-JUN-09:09 | 1343.25 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2254.10 | 29-JUN-15:00 | 4389.35 | 16-JUN-11:05 |
July | 2159.72 | 01-JUL-12:09 | 5587.06 | 01-JUL-09:09 | 1343.25 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3402.03 | 17-JUL-16:00 | 2602.56 | 05-JUL-11:10 |
August | 2159.72 | 04-AUG-12:09 | 5587.06 | 01-AUG-09:09 | 1343.25 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3013.91 | 05-AUG-16:00 | 4141.93 | 17-AUG-11:05 |
September | 2159.72 | 01-SEP-12:09 | 5587.06 | 01-SEP-09:09 | 1343.25 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2770.45 | 02-SEP-15:00 | 5059.85 | 12-SEP-11:10 |
October | 2159.72 | 01-OCT-12:09 | 5587.06 | 01-OCT-09:09 | 1343.25 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 300.32 | 18-OCT-14:00 | 6168.47 | 10-OCT-11:10 |
November | 2159.72 | 03-NOV-12:09 | 5587.06 | 01-NOV-09:09 | 1343.25 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 10834.03 | 26-NOV-18:00 |
December | 2159.72 | 01-DEC-13:09 | 5587.06 | 01-DEC-10:09 | 1343.25 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 13286.18 | 28-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 5587.06 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2602.56 | |||||
Maximum of Months | 2159.72 | 5587.06 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 3402.03 | 15364.08 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 3268.27 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.71 | 10-JAN-18:00 |
February | 1079.86 | 03-FEB-13:09 | 3268.27 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.34 | 09-FEB-18:00 |
March | 1079.86 | 03-MAR-13:09 | 3268.27 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.56 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3268.27 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.43 | 27-APR-11:10 |
May | 1079.86 | 05-MAY-12:09 | 3268.27 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 20-MAY-16:00 | 3450.85 | 22-MAY-16:00 |
June | 1079.86 | 02-JUN-12:09 | 3268.27 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.97 | 29-JUN-15:00 | 2518.16 | 16-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 3268.27 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.59 | 17-JUL-16:00 | 1485.07 | 05-JUL-11:10 |
August | 1079.86 | 04-AUG-12:09 | 3268.27 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.32 | 05-AUG-16:00 | 2361.32 | 17-AUG-11:05 |
September | 1079.86 | 01-SEP-12:09 | 3268.27 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.52 | 02-SEP-15:00 | 2800.70 | 12-SEP-11:05 |
October | 1079.86 | 01-OCT-12:09 | 3268.27 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.34 | 18-OCT-14:00 | 3337.09 | 10-OCT-11:10 |
November | 1079.86 | 03-NOV-12:09 | 3268.27 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.64 | 26-NOV-18:00 |
December | 1079.86 | 01-DEC-13:09 | 3268.27 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.57 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3268.27 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1485.07 | |||||
Maximum of Months | 1079.86 | 3268.27 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.59 | 8415.71 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3006.97 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.69 | 10-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3006.97 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.33 | 09-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3006.97 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.56 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3006.97 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.42 | 27-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3006.97 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 20-MAY-16:00 | 3450.84 | 22-MAY-16:00 |
June | 1079.86 | 03-JUN-12:09 | 3006.97 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.97 | 29-JUN-15:00 | 2514.35 | 16-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 3006.97 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.58 | 17-JUL-16:00 | 1485.07 | 05-JUL-11:10 |
August | 1079.86 | 05-AUG-12:09 | 3006.97 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.32 | 05-AUG-16:00 | 2368.37 | 17-AUG-11:05 |
September | 1079.86 | 02-SEP-12:09 | 3006.97 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.52 | 02-SEP-15:00 | 2794.24 | 12-SEP-11:05 |
October | 1079.86 | 07-OCT-12:09 | 3006.97 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.34 | 18-OCT-14:00 | 3337.08 | 10-OCT-11:10 |
November | 1079.86 | 04-NOV-12:09 | 3006.97 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.64 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3006.97 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.58 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1485.07 | |||||
Maximum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.58 | 8415.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3006.97 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.69 | 10-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3006.97 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.33 | 09-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3006.97 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.56 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3006.97 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.42 | 27-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3006.97 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 20-MAY-16:00 | 3450.82 | 22-MAY-16:00 |
June | 1079.86 | 03-JUN-12:09 | 3006.97 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.97 | 29-JUN-15:00 | 2505.45 | 16-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 3006.97 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.58 | 17-JUL-16:00 | 1485.07 | 05-JUL-11:10 |
August | 1079.86 | 05-AUG-12:09 | 3006.97 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.32 | 05-AUG-16:00 | 2365.60 | 17-AUG-11:05 |
September | 1079.86 | 02-SEP-12:09 | 3006.97 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.52 | 02-SEP-15:00 | 2782.54 | 12-SEP-11:05 |
October | 1079.86 | 07-OCT-12:09 | 3006.97 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.34 | 18-OCT-14:00 | 3337.08 | 10-OCT-11:10 |
November | 1079.86 | 04-NOV-12:09 | 3006.97 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.64 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3006.97 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.58 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1485.07 | |||||
Maximum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.58 | 8415.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3006.97 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.70 | 10-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3006.97 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.33 | 09-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3006.97 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.56 | 04-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3006.97 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.42 | 27-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3006.97 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 20-MAY-16:00 | 3450.83 | 22-MAY-16:00 |
June | 1079.86 | 03-JUN-12:09 | 3006.97 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.96 | 29-JUN-15:00 | 2472.10 | 16-JUN-11:05 |
July | 1079.86 | 01-JUL-12:09 | 3006.97 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.58 | 17-JUL-16:00 | 1485.07 | 05-JUL-11:10 |
August | 1079.86 | 05-AUG-12:09 | 3006.97 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.32 | 05-AUG-16:00 | 2336.95 | 17-AUG-11:05 |
September | 1079.86 | 02-SEP-12:09 | 3006.97 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.52 | 02-SEP-15:00 | 2742.95 | 12-SEP-11:05 |
October | 1079.86 | 07-OCT-12:09 | 3006.97 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.34 | 18-OCT-14:00 | 3337.08 | 10-OCT-11:10 |
November | 1079.86 | 04-NOV-12:09 | 3006.97 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.64 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3006.97 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.58 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1485.07 | |||||
Maximum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.58 | 8415.70 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 3712.57 | 01-JAN-11:09 | 1343.25 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 15122.72 | 10-JAN-18:00 |
February | 2879.63 | 04-FEB-15:09 | 3712.57 | 01-FEB-10:09 | 1343.25 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 12193.07 | 09-FEB-18:00 |
March | 2879.63 | 04-MAR-15:09 | 3712.57 | 01-MAR-10:09 | 1343.25 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 11770.37 | 04-MAR-18:00 |
April | 2879.63 | 01-APR-14:09 | 3712.57 | 01-APR-09:09 | 1343.25 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 6915.20 | 27-APR-11:10 |
May | 2879.63 | 06-MAY-14:09 | 3712.57 | 01-MAY-09:09 | 1343.25 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1561.15 | 20-MAY-16:00 | 6232.48 | 22-MAY-16:00 |
June | 2879.63 | 03-JUN-14:09 | 3712.57 | 01-JUN-09:09 | 1343.25 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2159.35 | 29-JUN-15:00 | 4348.49 | 16-JUN-11:05 |
July | 2879.63 | 01-JUL-14:09 | 3712.57 | 01-JUL-09:09 | 1343.25 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3334.50 | 17-JUL-16:00 | 2518.16 | 05-JUL-11:10 |
August | 2879.63 | 05-AUG-14:09 | 3712.57 | 01-AUG-09:09 | 1343.25 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2946.72 | 05-AUG-16:00 | 3931.63 | 17-AUG-11:05 |
September | 2879.63 | 02-SEP-14:09 | 3712.57 | 01-SEP-09:09 | 1343.25 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2681.20 | 02-SEP-15:00 | 4867.42 | 12-SEP-11:10 |
October | 2879.63 | 07-OCT-14:09 | 3712.57 | 01-OCT-10:09 | 1343.25 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 290.66 | 18-OCT-14:00 | 6005.89 | 10-OCT-11:10 |
November | 2879.63 | 04-NOV-14:09 | 3712.57 | 01-NOV-09:09 | 1343.25 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 10596.59 | 26-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 3712.57 | 01-DEC-10:09 | 1343.25 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 13191.80 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2518.16 | |||||
Maximum of Months | 2879.63 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 3334.50 | 15122.72 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.69 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.32 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.55 | 04-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.41 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 20-MAY-16:00 | 3450.82 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.98 | 29-JUN-15:00 | 2422.46 | 16-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.61 | 17-JUL-16:00 | 1460.21 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.34 | 05-AUG-16:00 | 2244.89 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.54 | 02-SEP-15:00 | 2699.79 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.35 | 18-OCT-14:00 | 3337.07 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.63 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.58 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1460.21 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.61 | 8415.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.69 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.32 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.55 | 04-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.41 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 20-MAY-16:00 | 3450.82 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.98 | 29-JUN-15:00 | 2422.12 | 16-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.61 | 17-JUL-16:00 | 1454.14 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.34 | 05-AUG-16:00 | 2238.40 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.54 | 02-SEP-15:00 | 2699.79 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.35 | 18-OCT-14:00 | 3337.07 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.63 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.58 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1454.14 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.61 | 8415.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8415.69 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 6783.32 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6558.55 | 04-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 3838.39 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 20-MAY-16:00 | 3450.82 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1196.98 | 29-JUN-15:00 | 2422.12 | 16-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.61 | 17-JUL-16:00 | 1418.23 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1638.34 | 05-AUG-16:00 | 2206.53 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1488.54 | 02-SEP-15:00 | 2699.79 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 161.35 | 18-OCT-14:00 | 3337.07 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 5891.64 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7350.58 | 31-DEC-12:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1418.23 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1854.61 | 8415.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8656.72 | 10-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 7003.99 | 09-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6689.31 | 04-MAR-14:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:05 | 4075.67 | 27-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 912.60 | 20-MAY-16:00 | 3775.94 | 22-MAY-16:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1291.67 | 29-JUN-15:00 | 2462.91 | 16-JUN-11:05 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1922.11 | 17-JUL-16:00 | 1368.10 | 05-JUL-11:10 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1705.54 | 05-AUG-16:00 | 2304.67 | 17-AUG-11:05 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1577.77 | 02-SEP-15:00 | 2891.97 | 12-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 171.02 | 18-OCT-14:00 | 3499.42 | 10-OCT-11:10 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 6128.78 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 7465.44 | 28-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1368.10 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1922.11 | 8656.72 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 20520.43 | 28-JAN-00:01 | 1619.79 | 26465.00 | 6716.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 357.00 |
February | 17029.54 | 04-FEB-00:01 | 1439.81 | 23524.44 | 5970.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 403.99 |
March | 15377.85 | 04-MAR-00:01 | 1259.84 | 20583.89 | 5223.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 464.30 |
April | 9933.00 | 28-APR-23:03 | 719.91 | 11762.22 | 2985.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 240.14 |
May | 8938.95 | 20-MAY-16:10 | 1799.77 | 5587.06 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 1553.57 | 0.00 |
June | 12282.96 | 22-JUN-07:03 | 539.93 | 225.00 | 223.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 182.69 |
July | 27158.36 | 17-JUL-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.22 |
August | 28928.19 | 07-AUG-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.23 |
September | 31752.63 | 04-SEP-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 172.40 |
October | 8927.23 | 18-OCT-14:00 | 1439.81 | 5587.06 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 300.32 | 0.00 |
November | 13977.97 | 26-NOV-18:20 | 12958.32 | 33522.33 | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1903.94 |
December | 18089.55 | 29-DEC-00:01 | 1439.81 | 23524.44 | 5970.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.32 |
Annual Sum or Average | |||||||||||
Minimum of Months | 8927.23 | 539.93 | 225.00 | 223.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31752.63 | 12958.32 | 33522.33 | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 1553.57 | 1903.94 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5977.57 | 06-JAN-18:42 | 4499.40 | 16341.36 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 824.60 |
February | 3952.30 | 22-FEB-09:43 | 269.96 | 5160.43 | 1119.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.98 |
March | 3709.06 | 01-MAR-09:03 | 269.96 | 5160.43 | 1119.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 567.07 |
April | 18198.49 | 25-APR-20:02 | 5399.28 | 32682.71 | 6716.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 19335.16 | 13-MAY-20:14 | 4859.35 | 29414.44 | 6044.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 |
June | 20247.64 | 24-JUN-21:40 | 4859.35 | 29414.44 | 6044.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.79 |
July | 19045.84 | 28-JUL-22:54 | 3239.57 | 29414.44 | 6044.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.89 |
August | 20081.22 | 14-AUG-20:36 | 3779.50 | 22877.90 | 4701.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.24 |
September | 20777.22 | 08-SEP-20:30 | 1619.78 | 9804.81 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.29 |
October | 19434.15 | 15-OCT-18:08 | 2879.62 | 13073.08 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.53 |
November | 18124.67 | 04-NOV-19:22 | 5399.28 | 32682.71 | 6716.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.56 |
December | 7927.94 | 29-DEC-20:52 | 3239.57 | 19609.63 | 4029.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3709.06 | 269.96 | 5160.43 | 1119.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20777.22 | 5399.28 | 32682.71 | 6716.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 824.60 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4039.03 | 21-JAN-18:43 | 269.96 | 4747.86 | 1119.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 609.35 |
February | 5277.46 | 01-FEB-19:23 | 1439.81 | 12027.90 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 845.13 |
March | 5393.53 | 01-MAR-08:61 | 809.89 | 337.50 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 665.53 |
April | 4007.83 | 28-APR-07:01 | 899.88 | 375.00 | 3731.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 502.09 |
May | 5098.60 | 20-MAY-16:00 | 539.93 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 0.00 |
June | 13028.76 | 26-JUN-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.03 |
July | 20426.10 | 27-JUL-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.10 |
August | 19084.02 | 01-AUG-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.23 |
September | 19467.48 | 03-SEP-07:02 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.26 |
October | 7047.24 | 19-OCT-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.37 |
November | 4996.44 | 11-NOV-09:01 | 809.89 | 337.50 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 656.07 |
December | 3730.20 | 23-DEC-18:03 | 269.96 | 4747.86 | 1119.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 642.81 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3730.20 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20426.10 | 1439.81 | 12027.90 | 3731.25 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 845.13 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5232.83 | 19-JAN-11:13 | 719.90 | 12027.90 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 753.11 |
February | 6020.54 | 02-FEB-18:32 | 4499.40 | 15034.87 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 832.46 |
March | 5816.76 | 03-MAR-11:42 | 899.88 | 15034.87 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 876.85 |
April | 3891.76 | 27-APR-07:01 | 899.88 | 375.00 | 3731.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 586.95 |
May | 5040.71 | 20-MAY-16:00 | 539.93 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 0.00 |
June | 13539.45 | 26-JUN-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.04 |
July | 20539.63 | 27-JUL-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.18 |
August | 19874.25 | 01-AUG-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.24 |
September | 19606.11 | 03-SEP-07:02 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.67 |
October | 5910.28 | 19-OCT-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.35 |
November | 6004.94 | 26-NOV-11:42 | 1799.76 | 15034.87 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 905.18 |
December | 4824.39 | 14-DEC-10:23 | 719.90 | 12027.90 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 657.63 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3891.76 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20539.63 | 4499.40 | 15034.87 | 3731.25 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 905.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3598.68 | 20-JAN-10:33 | 539.93 | 9020.92 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 653.77 |
February | 5248.32 | 01-FEB-18:33 | 3599.52 | 12027.90 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 857.03 |
March | 5233.23 | 01-MAR-08:61 | 809.89 | 337.50 | 3358.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 651.42 |
April | 3808.68 | 27-APR-07:01 | 899.88 | 375.00 | 3731.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 575.33 |
May | 4799.54 | 20-MAY-16:00 | 539.93 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 0.00 |
June | 11381.68 | 26-JUN-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.02 |
July | 19142.64 | 27-JUL-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.00 |
August | 18772.29 | 09-AUG-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.26 |
September | 19293.32 | 03-SEP-07:02 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.65 |
October | 4756.54 | 18-OCT-14:00 | 539.93 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 161.34 | 0.00 |
November | 4323.12 | 10-NOV-08:61 | 719.90 | 300.00 | 2985.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 626.76 |
December | 1958.69 | 06-DEC-18:10 | 899.88 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 400.13 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1958.69 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19293.32 | 3599.52 | 12027.90 | 3731.25 | 0.00 | 0.00 | 0.00 | 0.00 | 867.12 | 857.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6906.67 | 03-JAN-11:23 | 4643.40 | 11137.71 | 4029.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 928.78 |
February | 4956.38 | 27-FEB-18:40 | 1223.84 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 629.43 |
March | 5816.46 | 11-MAR-18:33 | 1187.85 | 5861.95 | 2238.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 707.38 |
April | 4469.65 | 26-APR-17:30 | 1223.84 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 529.85 |
May | 7765.16 | 20-MAY-16:00 | 2663.65 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 1561.15 | 0.00 |
June | 13844.18 | 26-JUN-07:03 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 237.75 |
July | 27865.60 | 27-JUL-07:02 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 382.17 |
August | 29672.97 | 08-AUG-07:03 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 171.46 |
September | 31336.30 | 05-SEP-07:02 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 232.62 |
October | 8746.77 | 21-OCT-08:62 | 1583.79 | 300.00 | 2985.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 907.44 |
November | 6264.59 | 22-NOV-10:33 | 1187.85 | 11137.71 | 4029.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 745.86 |
December | 9673.04 | 14-DEC-18:33 | 4895.36 | 14850.28 | 5373.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1108.77 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4469.65 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31336.30 | 4895.36 | 14850.28 | 5373.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1561.15 | 1108.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4039.28 | 03-JAN-18:12 | 2447.67 | 7425.14 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 653.66 |
February | 4691.24 | 23-FEB-18:53 | 2447.67 | 7425.14 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 631.36 |
March | 3380.56 | 31-MAR-18:53 | 1403.81 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 494.65 |
April | 2444.67 | 20-APR-10:15 | 1547.79 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 442.16 |
May | 4026.84 | 20-MAY-16:00 | 1331.82 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 0.00 |
June | 6209.94 | 26-JUN-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.24 |
July | 13225.00 | 17-JUL-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.55 |
August | 13139.65 | 08-AUG-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.82 |
September | 13607.43 | 05-SEP-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 129.61 |
October | 3997.77 | 18-OCT-14:40 | 1241.83 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 161.24 | 0.00 |
November | 2457.67 | 06-NOV-11:40 | 773.90 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 349.17 |
December | 4342.28 | 22-DEC-11:23 | 3095.59 | 7425.14 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 619.85 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2444.67 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13607.43 | 3095.59 | 7425.14 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 653.66 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1986.35 | 17-JAN-11:25 | 1547.79 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 410.64 |
February | 3271.65 | 15-FEB-19:03 | 1403.81 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 537.96 |
March | 2208.13 | 16-MAR-15:25 | 1943.74 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2500.19 |
April | 2531.34 | 20-APR-10:55 | 1547.79 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 482.70 |
May | 3936.24 | 20-MAY-16:00 | 1331.82 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 0.00 |
June | 5490.19 | 26-JUN-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.14 |
July | 13082.13 | 17-JUL-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.79 |
August | 13015.30 | 08-AUG-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.04 |
September | 13484.75 | 05-SEP-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.81 |
October | 3922.18 | 18-OCT-14:40 | 1241.83 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 161.24 | 0.00 |
November | 2422.91 | 06-NOV-11:50 | 773.90 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 345.20 |
December | 4481.81 | 16-DEC-11:53 | 4175.44 | 7425.14 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 648.60 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1986.35 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13484.75 | 4175.44 | 7425.14 | 2686.50 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 2500.19 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 914.51 | 14-JAN-12:00 | 1043.86 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 285.20 |
February | 1922.01 | 27-FEB-18:50 | 611.92 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 347.76 |
March | 3108.63 | 01-MAR-10:13 | 593.92 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 491.54 |
April | 3789.14 | 27-APR-10:43 | 2321.69 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 630.79 |
May | 3697.65 | 20-MAY-16:00 | 1331.82 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 867.14 | 0.00 |
June | 5008.72 | 23-JUN-14:10 | 1241.83 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1010.05 | 0.00 |
July | 12853.55 | 17-JUL-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.83 |
August | 12848.24 | 07-AUG-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.79 |
September | 13321.69 | 05-SEP-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126.23 |
October | 3682.39 | 18-OCT-14:40 | 1241.83 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 161.24 | 0.00 |
November | 3601.69 | 13-NOV-19:33 | 1403.81 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 508.19 |
December | 3380.04 | 20-DEC-19:03 | 1403.81 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 481.59 |
Annual Sum or Average | |||||||||||
Minimum of Months | 914.51 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13321.69 | 2321.69 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 1010.05 | 630.79 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 295.54 | 14-JAN-12:00 | 1043.86 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 393.17 |
February | 1179.87 | 27-FEB-18:10 | 611.92 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 453.57 |
March | 2601.00 | 16-MAR-17:33 | 1835.76 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 679.87 |
April | 1416.74 | 13-APR-19:35 | 395.95 | 1953.98 | 746.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.45 |
May | 3342.13 | 20-MAY-16:00 | 1331.82 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 912.60 | 0.00 |
June | 4902.75 | 23-JUN-14:10 | 1241.83 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1034.37 | 0.00 |
July | 14129.01 | 17-JUL-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.08 |
August | 13302.48 | 07-AUG-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.99 |
September | 16843.78 | 05-SEP-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.81 |
October | 3375.61 | 18-OCT-14:40 | 1241.83 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 170.90 | 0.00 |
November | 2245.08 | 15-NOV-18:35 | 1223.84 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 509.72 |
December | 307.82 | 07-DEC-12:00 | 773.90 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 400.71 |
Annual Sum or Average | |||||||||||
Minimum of Months | 295.54 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16843.78 | 1835.76 | 5568.86 | 2014.88 | 0.00 | 0.00 | 0.00 | 0.00 | 1034.37 | 679.87 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.774664E+11 | 63924.98 | 07-JAN-17:10 | 0.172002E+12 | 302456.48 | 08-JAN-17:00 |
February | 0.690788E+11 | 64885.73 | 02-FEB-19:40 | 0.968417E+11 | 233186.17 | 05-FEB-17:00 |
March | 0.762106E+11 | 60896.71 | 07-MAR-19:19 | 0.773610E+11 | 214225.26 | 06-MAR-08:09 |
April | 0.716709E+11 | 60258.53 | 07-APR-13:50 | 0.301957E+11 | 110498.66 | 29-APR-07:10 |
May | 0.752953E+11 | 71587.81 | 20-MAY-15:00 | 0.188946E+11 | 111829.59 | 08-MAY-07:10 |
June | 0.794858E+11 | 76548.39 | 29-JUN-14:50 | 0.509442E+09 | 24553.43 | 16-JUN-11:09 |
July | 0.891916E+11 | 91682.11 | 17-JUL-16:40 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.882685E+11 | 85897.77 | 06-AUG-15:09 | 12680396.77 | 2898.07 | 18-AUG-07:10 |
September | 0.791900E+11 | 84549.67 | 03-SEP-13:00 | 0.271566E+10 | 40632.86 | 20-SEP-07:10 |
October | 0.760315E+11 | 67218.46 | 18-OCT-13:50 | 0.114614E+11 | 92083.61 | 10-OCT-07:10 |
November | 0.739891E+11 | 63008.46 | 28-NOV-18:49 | 0.534474E+11 | 189705.30 | 26-NOV-17:00 |
December | 0.771702E+11 | 63731.14 | 30-DEC-17:49 | 0.123640E+12 | 264614.00 | 31-DEC-17:00 |
Annual Sum or Average | 0.933049E+12 | 0.587081E+12 | ||||
Minimum of Months | 0.690788E+11 | 60258.53 | 0.00 | 0.00 | ||
Maximum of Months | 0.891916E+11 | 91682.11 | 0.172002E+12 | 302456.48 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.381118E+11 | 0.704003E+10 | 0.108325E+11 | 0.00 | 0.157169E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576518E+10 | 0.00 |
February | 0.345095E+11 | 0.564290E+10 | 0.980803E+10 | 0.00 | 0.138751E+11 | 0.00 | 0.00 | 632951.25 | 0.00 | 0.00 | 0.00 | 0.524266E+10 | 0.00 |
March | 0.387104E+11 | 0.524511E+10 | 0.110038E+11 | 0.00 | 0.154292E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.582214E+10 | 0.00 |
April | 0.369865E+11 | 0.406317E+10 | 0.105115E+11 | 0.00 | 0.145011E+11 | 0.00 | 0.00 | 89627033.21 | 0.00 | 0.00 | 0.00 | 0.551897E+10 | 0.00 |
May | 0.383972E+11 | 0.335770E+10 | 0.109147E+11 | 0.00 | 0.151076E+11 | 0.00 | 0.00 | 0.191015E+10 | 0.00 | 0.00 | 0.00 | 0.560783E+10 | 0.00 |
June | 0.374142E+11 | 0.288222E+10 | 0.106349E+11 | 0.00 | 0.147378E+11 | 0.00 | 0.00 | 0.849889E+10 | 0.00 | 0.00 | 0.00 | 0.531767E+10 | 0.00 |
July | 0.379970E+11 | 0.311028E+10 | 0.107982E+11 | 0.00 | 0.150019E+11 | 0.00 | 0.00 | 0.169184E+11 | 0.00 | 0.00 | 0.00 | 0.536583E+10 | 0.00 |
August | 0.386827E+11 | 0.379410E+10 | 0.109970E+11 | 0.00 | 0.152984E+11 | 0.00 | 0.00 | 0.141140E+11 | 0.00 | 0.00 | 0.00 | 0.538234E+10 | 0.00 |
September | 0.370138E+11 | 0.463309E+10 | 0.105184E+11 | 0.00 | 0.145671E+11 | 0.00 | 0.00 | 0.724302E+10 | 0.00 | 0.00 | 0.00 | 0.521461E+10 | 0.00 |
October | 0.381120E+11 | 0.582813E+10 | 0.108325E+11 | 0.00 | 0.149269E+11 | 0.00 | 0.00 | 0.872582E+09 | 0.00 | 0.00 | 0.00 | 0.545933E+10 | 0.00 |
November | 0.369307E+11 | 0.655576E+10 | 0.104978E+11 | 0.00 | 0.146023E+11 | 0.00 | 0.00 | 1477407.33 | 0.00 | 0.00 | 0.00 | 0.540095E+10 | 0.00 |
December | 0.380245E+11 | 0.729878E+10 | 0.108050E+11 | 0.00 | 0.153545E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568749E+10 | 0.00 |
Annual Sum or Average | 0.450890E+12 | 0.594513E+11 | 0.128154E+12 | 0.179119E+12 | 0.00 | 0.496489E+11 | 0.657850E+11 | ||||||
Minimum of Months | 0.345095E+11 | 0.288222E+10 | 0.980803E+10 | 0.00 | 0.138751E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521461E+10 | 0.00 |
Maximum of Months | 0.387104E+11 | 0.729878E+10 | 0.110038E+11 | 0.00 | 0.157169E+11 | 0.00 | 0.00 | 0.169184E+11 | 0.00 | 0.00 | 0.00 | 0.582214E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.172002E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.968417E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.773610E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.301957E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.188946E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.509442E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 12680396.77 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.271566E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.114614E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.534474E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.123640E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.587081E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.172002E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 29013.96 | 01-JAN-11:09 | 5459.01 | 01-JAN-06:10 | 8059.50 | 01-JAN-11:09 | 0.00 | 11969.69 | 08-JAN-17:00 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 29013.96 | 01-FEB-10:09 | 5459.01 | 01-FEB-06:10 | 8059.50 | 01-FEB-10:09 | 0.00 | 11605.33 | 05-FEB-17:00 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 29013.96 | 01-MAR-10:09 | 5459.01 | 01-MAR-06:10 | 8059.50 | 01-MAR-10:09 | 0.00 | 11548.09 | 06-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 29013.96 | 01-APR-09:09 | 5459.01 | 01-APR-05:10 | 8059.50 | 01-APR-09:09 | 0.00 | 10986.93 | 29-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 29013.96 | 01-MAY-09:09 | 5459.01 | 01-MAY-05:10 | 8059.50 | 01-MAY-09:09 | 0.00 | 10965.11 | 08-MAY-07:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 29013.96 | 01-JUN-09:09 | 5459.01 | 01-JUN-20:10 | 8059.50 | 01-JUN-09:09 | 0.00 | 10578.96 | 16-JUN-11:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 29013.96 | 01-JUL-09:09 | 5459.01 | 01-JUL-20:30 | 8059.50 | 01-JUL-09:09 | 0.00 | 11613.96 | 17-JUL-16:10 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 29013.96 | 01-AUG-09:09 | 5459.01 | 01-AUG-19:00 | 8059.50 | 01-AUG-09:09 | 0.00 | 11264.71 | 06-AUG-15:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 29013.96 | 01-SEP-09:09 | 5459.01 | 01-SEP-05:10 | 8059.50 | 01-SEP-09:09 | 0.00 | 11214.66 | 02-SEP-14:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 29013.96 | 01-OCT-10:09 | 5459.01 | 01-OCT-05:10 | 8059.50 | 01-OCT-10:09 | 0.00 | 10909.63 | 10-OCT-08:09 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 29013.96 | 01-NOV-09:09 | 5459.01 | 01-NOV-05:10 | 8059.50 | 01-NOV-09:09 | 0.00 | 11380.18 | 26-NOV-17:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 29013.96 | 01-DEC-10:09 | 5459.01 | 01-DEC-06:10 | 8059.50 | 01-DEC-10:09 | 0.00 | 11786.42 | 31-DEC-12:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 29013.96 | 5459.01 | 8059.50 | 0.00 | 10578.96 | 0.00 | 0.00 | |||||
Maximum of Months | 29013.96 | 5459.01 | 8059.50 | 0.00 | 11969.69 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 14008.81 | 21-JAN-14:20 | 0.00 |
February | 122.24 | 28-FEB-22:40 | 0.00 | 0.00 | 0.00 | 11886.68 | 06-FEB-13:30 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 9750.92 | 08-MAR-13:09 | 0.00 |
April | 5627.82 | 07-APR-13:00 | 0.00 | 0.00 | 0.00 | 11832.04 | 07-APR-11:20 | 0.00 |
May | 18837.32 | 20-MAY-15:00 | 0.00 | 0.00 | 0.00 | 11165.61 | 11-MAY-18:19 | 0.00 |
June | 23699.85 | 29-JUN-14:00 | 0.00 | 0.00 | 0.00 | 8870.63 | 12-JUN-13:09 | 0.00 |
July | 36924.20 | 17-JUL-16:10 | 0.00 | 0.00 | 0.00 | 10976.66 | 24-JUL-10:20 | 0.00 |
August | 32428.54 | 06-AUG-15:00 | 0.00 | 0.00 | 0.00 | 9706.34 | 08-AUG-12:00 | 0.00 |
September | 31466.76 | 02-SEP-14:00 | 0.00 | 0.00 | 0.00 | 7586.73 | 22-SEP-12:50 | 0.00 |
October | 14624.04 | 18-OCT-14:30 | 0.00 | 0.00 | 0.00 | 9684.55 | 23-OCT-13:39 | 0.00 |
November | 319.48 | 04-NOV-19:30 | 0.00 | 0.00 | 0.00 | 9726.30 | 09-NOV-13:00 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 9746.46 | 29-DEC-13:30 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 7586.73 | 0.00 | ||
Maximum of Months | 36924.20 | 0.00 | 0.00 | 0.00 | 14008.81 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 63924.98 | 07-JAN-17:10 | 29013.96 | 8059.50 | 5459.01 | 0.00 | 11692.91 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 64885.73 | 02-FEB-19:40 | 29013.96 | 8059.50 | 5459.01 | 0.00 | 11044.97 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 60896.71 | 07-MAR-19:19 | 29013.96 | 8059.50 | 5459.01 | 0.00 | 10791.94 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 60258.53 | 07-APR-13:50 | 29013.96 | 8059.50 | 0.00 | 0.00 | 10383.70 | 0.00 | 0.00 | 5195.62 | 0.00 |
May | 71587.81 | 20-MAY-15:00 | 29013.96 | 8059.50 | 0.00 | 0.00 | 10383.70 | 0.00 | 0.00 | 18837.32 | 0.00 |
June | 76548.39 | 29-JUN-14:50 | 29013.96 | 8059.50 | 0.00 | 0.00 | 10490.98 | 0.00 | 0.00 | 23533.75 | 0.00 |
July | 91682.11 | 17-JUL-16:40 | 29013.96 | 8059.50 | 0.00 | 0.00 | 11513.02 | 0.00 | 0.00 | 35536.08 | 0.00 |
August | 85897.77 | 06-AUG-15:09 | 29013.96 | 8059.50 | 0.00 | 0.00 | 11134.64 | 0.00 | 0.00 | 30710.63 | 0.00 |
September | 84549.67 | 03-SEP-13:00 | 29013.96 | 8059.50 | 0.00 | 0.00 | 11168.94 | 0.00 | 0.00 | 30882.01 | 0.00 |
October | 67218.46 | 18-OCT-13:50 | 29013.96 | 8059.50 | 0.00 | 0.00 | 10383.70 | 0.00 | 0.00 | 14299.02 | 0.00 |
November | 63008.46 | 28-NOV-18:49 | 29013.96 | 8059.50 | 5459.01 | 0.00 | 10786.80 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 63731.14 | 30-DEC-17:49 | 29013.96 | 8059.50 | 5459.01 | 0.00 | 11498.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 60258.53 | 29013.96 | 8059.50 | 0.00 | 0.00 | 10383.70 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 91682.11 | 29013.96 | 8059.50 | 5459.01 | 0.00 | 11692.91 | 0.00 | 0.00 | 35536.08 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 302456.48 | 08-JAN-17:00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 233186.17 | 05-FEB-17:00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 214225.26 | 06-MAR-08:09 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 110498.66 | 29-APR-07:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 111829.59 | 08-MAY-07:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 24553.43 | 16-JUN-11:09 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 2898.07 | 18-AUG-07:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 40632.86 | 20-SEP-07:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 92083.61 | 10-OCT-07:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 189705.30 | 26-NOV-17:00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 264614.00 | 31-DEC-17:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 302456.48 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.83 | 20.25 | 1.17 | 20.22 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1.50 | 20.44 | 0.17 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1.50 | 20.46 | 0.33 | 20.39 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.33 | 20.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.50 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.33 | 20.41 | 0.33 | 20.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 9.17 | 20.37 | 2.00 | 20.26 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3.83 | 20.54 | 1.17 | 20.39 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.83 | 20.37 | 0.17 | 20.45 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.33 | 20.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.67 | 20.44 | 0.17 | 20.45 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.83 | 20.54 | 0.17 | 20.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.00 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.17 | 20.40 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.00 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.33 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 20.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.17 | 20.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.83 | 20.38 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.33 | 20.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.50 | 20.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 20.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.17 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 20.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2.00 | 20.32 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.50 | 20.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.33 | 19.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.83 | 20.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 20.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 20.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4.33 | 20.05 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.33 | 20.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.17 | 20.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.83 | 20.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 20.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 20.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4.17 | 20.23 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.17 | 20.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.17 | 20.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.83 | 20.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.33 | 20.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.83 | 20.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4.33 | 20.24 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.17 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.67 | 19.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 1.33 | 20.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.67 | 18.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.33 | 20.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.33 | 20.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 6.33 | 19.99 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.67 | 20.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 16.17 | 16.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 4.33 | 19.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 4.17 | 18.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.50 | 20.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.67 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1.17 | 19.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6.00 | 17.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 33.00 | 17.46 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 16.17 | 20.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.05 | 377.17 | 21.03 | 377.17 | 21.03 |
February | 448.00 | 21.13 | 225.17 | 21.00 | 225.17 | 21.00 |
March | 496.00 | 21.08 | 180.33 | 21.00 | 180.33 | 21.00 |
April | 480.00 | 21.59 | 70.17 | 20.97 | 70.17 | 20.97 |
May | 393.00 | 21.97 | 34.83 | 21.43 | 29.83 | 21.02 |
June | 152.00 | 23.10 | 108.33 | 23.89 | 0.00 | 0.00 |
July | 29.33 | 23.60 | 225.33 | 23.89 | 0.83 | 23.89 |
August | 63.17 | 23.19 | 140.00 | 23.89 | 0.00 | 0.00 |
September | 205.50 | 22.44 | 130.17 | 23.88 | 5.67 | 23.74 |
October | 425.50 | 22.14 | 8.00 | 21.06 | 8.00 | 21.06 |
November | 480.00 | 21.35 | 115.50 | 21.10 | 115.50 | 21.10 |
December | 496.00 | 21.05 | 309.83 | 21.01 | 309.83 | 21.01 |
Annual Sum or Average | 4164.50 | 21.55 | 1924.83 | 21.93 | 1322.50 | 21.03 |
Minimum of Months | 29.33 | 21.05 | 8.00 | 20.97 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.60 | 377.17 | 23.89 | 377.17 | 23.89 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.34 | 264.33 | 21.11 | 264.33 | 21.11 |
February | 448.00 | 21.72 | 130.67 | 21.13 | 130.67 | 21.13 |
March | 496.00 | 21.70 | 75.00 | 21.15 | 75.00 | 21.15 |
April | 471.00 | 22.57 | 6.50 | 21.14 | 6.50 | 21.14 |
May | 342.33 | 22.65 | 18.00 | 23.24 | 4.33 | 21.20 |
June | 88.00 | 23.44 | 125.50 | 23.88 | 0.00 | 0.00 |
July | 22.50 | 23.56 | 233.50 | 23.87 | 0.00 | 0.00 |
August | 55.33 | 23.45 | 139.33 | 23.89 | 0.00 | 0.00 |
September | 147.33 | 23.00 | 130.33 | 23.87 | 5.83 | 23.89 |
October | 327.33 | 22.87 | 0.33 | 21.42 | 0.33 | 21.42 |
November | 476.17 | 22.20 | 36.50 | 21.15 | 36.50 | 21.15 |
December | 496.00 | 21.46 | 144.83 | 21.12 | 144.83 | 21.12 |
Annual Sum or Average | 3866.00 | 22.10 | 1304.83 | 22.48 | 668.33 | 21.15 |
Minimum of Months | 22.50 | 21.34 | 0.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.56 | 264.33 | 23.89 | 264.33 | 23.89 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 242.83 | 21.11 | 242.83 | 21.11 |
February | 336.00 | 21.36 | 128.67 | 21.11 | 128.67 | 21.11 |
March | 379.00 | 21.25 | 93.83 | 21.11 | 93.83 | 21.11 |
April | 355.67 | 22.07 | 13.83 | 21.11 | 13.83 | 21.11 |
May | 266.00 | 22.22 | 27.83 | 23.28 | 9.83 | 21.11 |
June | 56.67 | 23.15 | 121.17 | 24.17 | 0.00 | 0.00 |
July | 8.83 | 24.14 | 211.33 | 24.18 | 0.83 | 28.38 |
August | 31.50 | 23.46 | 145.83 | 24.23 | 0.50 | 29.00 |
September | 113.83 | 22.65 | 110.17 | 24.15 | 6.67 | 24.47 |
October | 245.67 | 22.35 | 3.00 | 22.08 | 2.33 | 21.11 |
November | 356.83 | 21.69 | 57.50 | 21.11 | 57.50 | 21.11 |
December | 369.00 | 21.12 | 175.83 | 21.11 | 175.83 | 21.11 |
Annual Sum or Average | 2890.00 | 21.69 | 1331.83 | 22.52 | 732.67 | 21.15 |
Minimum of Months | 8.83 | 21.11 | 3.00 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 24.14 | 242.83 | 24.23 | 242.83 | 29.00 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 258.83 | 21.11 | 258.83 | 21.11 |
February | 336.00 | 21.33 | 139.50 | 21.11 | 139.50 | 21.11 |
March | 379.00 | 21.22 | 105.83 | 21.11 | 105.83 | 21.11 |
April | 360.00 | 22.02 | 20.00 | 21.11 | 20.00 | 21.11 |
May | 273.67 | 22.20 | 27.33 | 22.96 | 12.50 | 21.11 |
June | 59.00 | 23.15 | 120.17 | 24.17 | 0.00 | 0.00 |
July | 9.00 | 24.12 | 211.50 | 24.18 | 0.83 | 28.41 |
August | 32.33 | 23.46 | 145.50 | 24.24 | 0.50 | 29.02 |
September | 121.50 | 22.67 | 109.83 | 24.15 | 6.67 | 24.48 |
October | 259.83 | 22.36 | 3.50 | 21.93 | 2.83 | 21.11 |
November | 358.00 | 21.62 | 66.83 | 21.11 | 66.83 | 21.11 |
December | 369.00 | 21.12 | 195.67 | 21.11 | 195.67 | 21.11 |
Annual Sum or Average | 2928.33 | 21.68 | 1404.50 | 22.43 | 810.00 | 21.15 |
Minimum of Months | 9.00 | 21.11 | 3.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 24.12 | 258.83 | 24.24 | 258.83 | 29.02 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 285.17 | 21.11 | 285.17 | 21.11 |
February | 336.00 | 21.29 | 157.00 | 21.11 | 157.00 | 21.11 |
March | 379.00 | 21.18 | 123.00 | 21.11 | 123.00 | 21.11 |
April | 360.00 | 21.90 | 33.83 | 21.11 | 33.83 | 21.11 |
May | 288.00 | 22.17 | 28.83 | 22.48 | 17.33 | 21.11 |
June | 75.67 | 23.21 | 108.67 | 24.18 | 0.00 | 0.00 |
July | 11.83 | 24.01 | 200.33 | 24.18 | 0.83 | 28.34 |
August | 36.83 | 23.40 | 135.67 | 24.24 | 0.50 | 28.97 |
September | 137.83 | 22.67 | 104.83 | 24.15 | 6.67 | 24.47 |
October | 290.67 | 22.37 | 3.83 | 21.11 | 3.83 | 21.11 |
November | 360.00 | 21.51 | 83.67 | 21.11 | 83.67 | 21.11 |
December | 369.00 | 21.11 | 213.33 | 21.11 | 213.33 | 21.11 |
Annual Sum or Average | 3015.83 | 21.67 | 1478.17 | 22.28 | 925.17 | 21.14 |
Minimum of Months | 11.83 | 21.11 | 3.83 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 24.01 | 285.17 | 24.24 | 285.17 | 28.97 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 308.33 | 21.11 | 308.33 | 21.11 |
February | 308.00 | 21.17 | 215.00 | 21.11 | 215.00 | 21.11 |
March | 348.00 | 21.11 | 165.00 | 21.11 | 165.00 | 21.11 |
April | 330.00 | 21.51 | 54.83 | 21.11 | 54.83 | 21.11 |
May | 301.83 | 21.96 | 36.33 | 21.22 | 35.50 | 21.11 |
June | 119.00 | 23.09 | 60.17 | 23.99 | 0.00 | 0.00 |
July | 19.17 | 23.57 | 139.83 | 24.02 | 0.33 | 28.26 |
August | 45.00 | 23.03 | 87.67 | 24.02 | 0.17 | 29.01 |
September | 161.00 | 22.40 | 78.50 | 24.04 | 6.33 | 24.01 |
October | 323.33 | 22.11 | 6.83 | 21.11 | 6.83 | 21.11 |
November | 330.00 | 21.21 | 116.67 | 21.11 | 116.67 | 21.11 |
December | 338.00 | 21.11 | 258.67 | 21.11 | 258.67 | 21.11 |
Annual Sum or Average | 2963.33 | 21.56 | 1527.83 | 21.81 | 1167.67 | 21.13 |
Minimum of Months | 19.17 | 21.11 | 6.83 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.57 | 308.33 | 24.04 | 308.33 | 29.01 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 310.50 | 21.11 | 310.50 | 21.11 |
February | 308.00 | 21.20 | 222.00 | 21.11 | 222.00 | 21.11 |
March | 348.00 | 21.12 | 176.17 | 21.11 | 176.17 | 21.11 |
April | 330.00 | 21.64 | 61.33 | 21.11 | 61.33 | 21.11 |
May | 306.00 | 22.15 | 39.83 | 21.21 | 39.00 | 21.11 |
June | 121.17 | 23.36 | 50.67 | 24.04 | 0.00 | 0.00 |
July | 20.67 | 23.79 | 111.33 | 24.07 | 0.33 | 28.40 |
August | 47.83 | 23.33 | 61.33 | 24.11 | 0.17 | 29.08 |
September | 158.17 | 22.63 | 70.17 | 24.07 | 5.33 | 24.17 |
October | 325.33 | 22.34 | 7.17 | 21.11 | 7.17 | 21.11 |
November | 330.00 | 21.29 | 122.33 | 21.11 | 122.33 | 21.11 |
December | 338.00 | 21.11 | 264.00 | 21.11 | 264.00 | 21.11 |
Annual Sum or Average | 2973.17 | 21.67 | 1496.83 | 21.69 | 1208.33 | 21.13 |
Minimum of Months | 20.67 | 21.11 | 7.17 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.79 | 310.50 | 24.11 | 310.50 | 29.08 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 312.67 | 21.11 | 312.67 | 21.11 |
February | 308.00 | 21.20 | 229.83 | 21.11 | 229.83 | 21.11 |
March | 348.00 | 21.12 | 186.83 | 21.11 | 186.83 | 21.11 |
April | 330.00 | 21.62 | 69.83 | 21.11 | 69.83 | 21.11 |
May | 308.50 | 22.14 | 44.33 | 21.20 | 43.50 | 21.11 |
June | 125.33 | 23.35 | 47.50 | 24.05 | 0.00 | 0.00 |
July | 22.67 | 23.79 | 107.00 | 24.07 | 0.33 | 28.38 |
August | 50.67 | 23.34 | 57.33 | 24.12 | 0.17 | 29.05 |
September | 160.17 | 22.62 | 69.00 | 24.07 | 5.33 | 23.95 |
October | 328.00 | 22.33 | 8.17 | 21.11 | 8.17 | 21.11 |
November | 330.00 | 21.27 | 129.17 | 21.11 | 129.17 | 21.11 |
December | 338.00 | 21.11 | 270.83 | 21.11 | 270.83 | 21.11 |
Annual Sum or Average | 2989.33 | 21.67 | 1532.50 | 21.66 | 1256.67 | 21.12 |
Minimum of Months | 22.67 | 21.11 | 8.17 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.79 | 312.67 | 24.12 | 312.67 | 29.05 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 317.67 | 21.11 | 317.67 | 21.11 |
February | 308.00 | 21.18 | 250.50 | 21.11 | 250.50 | 21.11 |
March | 348.00 | 21.12 | 224.00 | 21.11 | 224.00 | 21.11 |
April | 330.00 | 21.54 | 95.67 | 21.11 | 95.67 | 21.11 |
May | 319.00 | 22.11 | 53.00 | 21.17 | 52.33 | 21.11 |
June | 143.17 | 23.29 | 41.17 | 24.04 | 0.00 | 0.00 |
July | 30.67 | 23.74 | 98.33 | 24.09 | 0.33 | 28.33 |
August | 59.00 | 23.33 | 53.67 | 24.12 | 0.17 | 29.00 |
September | 168.00 | 22.57 | 65.50 | 24.05 | 6.17 | 23.72 |
October | 331.67 | 22.24 | 12.50 | 21.11 | 12.50 | 21.11 |
November | 330.00 | 21.24 | 145.50 | 21.11 | 145.50 | 21.11 |
December | 338.00 | 21.11 | 287.33 | 21.11 | 287.33 | 21.11 |
Annual Sum or Average | 3045.50 | 21.66 | 1644.83 | 21.58 | 1392.17 | 21.12 |
Minimum of Months | 30.67 | 21.11 | 12.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.74 | 317.67 | 24.12 | 317.67 | 29.00 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 334.50 | 21.11 | 334.50 | 21.11 |
February | 308.00 | 21.15 | 278.83 | 21.11 | 278.83 | 21.11 |
March | 348.00 | 21.11 | 302.00 | 21.11 | 302.00 | 21.11 |
April | 330.00 | 21.42 | 190.17 | 21.11 | 190.17 | 21.11 |
May | 331.17 | 22.02 | 98.67 | 21.14 | 98.00 | 21.11 |
June | 189.50 | 23.20 | 35.83 | 23.98 | 0.00 | 0.00 |
July | 50.83 | 23.65 | 84.83 | 24.12 | 0.33 | 28.35 |
August | 80.00 | 23.32 | 50.50 | 24.13 | 0.17 | 29.09 |
September | 188.33 | 22.56 | 64.17 | 23.94 | 10.50 | 23.15 |
October | 337.17 | 22.11 | 28.00 | 21.11 | 28.00 | 21.11 |
November | 330.00 | 21.19 | 190.00 | 21.11 | 190.00 | 21.11 |
December | 338.00 | 21.11 | 322.00 | 21.11 | 322.00 | 21.11 |
Annual Sum or Average | 3171.00 | 21.66 | 1979.50 | 21.46 | 1754.50 | 21.12 |
Minimum of Months | 50.83 | 21.11 | 28.00 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.65 | 334.50 | 24.13 | 334.50 | 29.09 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.03367 | 10.63035 | -0.6665 | 14.87184 |
February | 448.00000 | 21.12547 | 13.87902 | -0.5689 | 12.44116 |
March | 496.00000 | 21.06992 | 15.61400 | -0.5489 | 11.64135 |
April | 480.00000 | 21.58421 | 20.82030 | -0.3633 | 8.81099 |
May | 496.00000 | 22.36472 | 24.38677 | -1.1841 | 37.35024 |
June | 480.00000 | 23.63538 | 31.23576 | -0.6389 | 14.73421 |
July | 496.00000 | 23.87054 | 33.80716 | -0.4892 | 10.22297 |
August | 496.00000 | 23.80175 | 30.41131 | -0.5412 | 11.67807 |
September | 480.00000 | 23.26851 | 31.53150 | -0.7398 | 19.30193 |
October | 496.00000 | 22.39225 | 23.09070 | -0.0931 | 6.71871 |
November | 480.00000 | 21.33452 | 17.16796 | -0.4342 | 9.61393 |
December | 496.00000 | 21.04331 | 12.93027 | -0.6038 | 13.03472 |
Annual Sum or Average | 5840.00000 | 22.21658 | 22.15963 | -0.5730 | 14.22805 |
Minimum of Months | 448.00000 | 21.03367 | 10.63035 | -1.1841 | 6.71871 |
Maximum of Months | 496.00000 | 23.87054 | 33.80716 | -0.0931 | 37.35024 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.31473 | 11.75530 | -0.5516 | 12.08100 |
February | 448.00000 | 21.70069 | 14.52300 | -0.4074 | 9.67446 |
March | 496.00000 | 21.67316 | 16.48770 | -0.3809 | 8.73184 |
April | 480.00000 | 22.57282 | 20.52771 | -0.1293 | 6.62510 |
May | 496.00000 | 23.00628 | 23.94593 | -0.9652 | 27.31369 |
June | 480.00000 | 23.77755 | 31.00192 | -0.5742 | 12.42791 |
July | 496.00000 | 23.83830 | 33.92534 | -0.4870 | 10.15103 |
August | 496.00000 | 23.81115 | 30.38706 | -0.5267 | 11.08277 |
September | 480.00000 | 23.59369 | 31.10279 | -0.6333 | 14.86659 |
October | 496.00000 | 23.20746 | 22.40642 | 0.08409 | 6.22772 |
November | 480.00000 | 22.19613 | 17.33125 | -0.2341 | 7.53218 |
December | 496.00000 | 21.43489 | 13.99174 | -0.4792 | 10.36237 |
Annual Sum or Average | 5840.00000 | 22.68134 | 22.31627 | -0.4412 | 11.44905 |
Minimum of Months | 448.00000 | 21.31473 | 11.75530 | -0.9652 | 6.22772 |
Maximum of Months | 496.00000 | 23.83830 | 33.92534 | 0.08409 | 27.31369 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.11113 | 10.30459 | -0.6164 | 13.26517 |
February | 336.00000 | 21.35885 | 13.15469 | -0.4911 | 10.86437 |
March | 379.00000 | 21.24802 | 15.33811 | -0.4723 | 10.01227 |
April | 360.00000 | 22.09313 | 19.79193 | -0.2282 | 7.44359 |
May | 375.00000 | 22.73651 | 23.23206 | -1.0518 | 31.63876 |
June | 366.00000 | 23.86459 | 30.61719 | -0.5528 | 12.28522 |
July | 369.00000 | 24.02367 | 33.43815 | -0.4361 | 9.39669 |
August | 379.00000 | 23.96312 | 29.96805 | -0.4843 | 10.41327 |
September | 360.00000 | 23.55700 | 31.03395 | -0.6439 | 16.04212 |
October | 371.00000 | 22.88843 | 22.12207 | 0.02158 | 6.53143 |
November | 360.00000 | 21.71432 | 16.61566 | -0.3352 | 8.52388 |
December | 369.00000 | 21.12221 | 12.78024 | -0.5574 | 11.74875 |
Annual Sum or Average | 4395.00000 | 22.48148 | 21.58652 | -0.4883 | 12.38300 |
Minimum of Months | 336.00000 | 21.11113 | 10.30459 | -1.0518 | 6.53143 |
Maximum of Months | 379.00000 | 24.02367 | 33.43815 | 0.02158 | 31.63876 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.11016 | 10.30667 | -0.6284 | 13.57254 |
February | 336.00000 | 21.32878 | 13.18095 | -0.5084 | 11.15474 |
March | 379.00000 | 21.22059 | 15.36449 | -0.4883 | 10.30581 |
April | 360.00000 | 22.01778 | 19.88634 | -0.2538 | 7.65235 |
May | 375.00000 | 22.68908 | 23.29399 | -1.0771 | 32.75690 |
June | 366.00000 | 23.85857 | 30.62895 | -0.5572 | 12.42144 |
July | 369.00000 | 24.02326 | 33.44018 | -0.4357 | 9.39375 |
August | 379.00000 | 23.96138 | 29.97248 | -0.4848 | 10.43518 |
September | 360.00000 | 23.53459 | 31.07254 | -0.6542 | 16.47182 |
October | 371.00000 | 22.83339 | 22.19620 | 0.00299 | 6.58053 |
November | 360.00000 | 21.63700 | 16.70594 | -0.3622 | 8.81162 |
December | 369.00000 | 21.11779 | 12.78628 | -0.5694 | 12.03030 |
Annual Sum or Average | 4395.00000 | 22.45264 | 21.62285 | -0.5023 | 12.66850 |
Minimum of Months | 336.00000 | 21.11016 | 10.30667 | -1.0771 | 6.58053 |
Maximum of Months | 379.00000 | 24.02326 | 33.44018 | 0.00299 | 32.75690 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10995 | 10.30616 | -0.6436 | 13.98219 |
February | 336.00000 | 21.28538 | 13.21826 | -0.5321 | 11.57245 |
March | 379.00000 | 21.18441 | 15.39787 | -0.5097 | 10.71681 |
April | 360.00000 | 21.89123 | 20.04634 | -0.2951 | 8.01467 |
May | 375.00000 | 22.59116 | 23.43790 | -1.1256 | 34.83382 |
June | 366.00000 | 23.83200 | 30.68009 | -0.5768 | 12.98746 |
July | 369.00000 | 24.01739 | 33.45638 | -0.4455 | 9.57180 |
August | 379.00000 | 23.94622 | 30.00245 | -0.4979 | 10.75265 |
September | 360.00000 | 23.47523 | 31.19238 | -0.6838 | 17.54090 |
October | 371.00000 | 22.70777 | 22.37059 | -0.0355 | 6.64104 |
November | 360.00000 | 21.51207 | 16.85705 | -0.4022 | 9.24584 |
December | 369.00000 | 21.11397 | 12.79112 | -0.5846 | 12.39834 |
Annual Sum or Average | 4395.00000 | 22.39743 | 21.69944 | -0.5286 | 13.22596 |
Minimum of Months | 336.00000 | 21.10995 | 10.30616 | -1.1256 | 6.64104 |
Maximum of Months | 379.00000 | 24.01739 | 33.45638 | -0.0355 | 34.83382 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10984 | 11.07410 | -0.6920 | 15.33485 |
February | 308.00000 | 21.17270 | 14.06838 | -0.5967 | 12.86086 |
March | 348.00000 | 21.11348 | 16.30831 | -0.5617 | 11.79592 |
April | 330.00000 | 21.50825 | 21.27797 | -0.4033 | 9.15377 |
May | 344.00000 | 22.20134 | 24.71553 | -1.2772 | 41.51919 |
June | 336.00000 | 23.61744 | 31.55127 | -0.6639 | 15.49675 |
July | 338.00000 | 23.90648 | 33.92288 | -0.4957 | 10.45179 |
August | 348.00000 | 23.80317 | 30.87953 | -0.5558 | 12.18199 |
September | 330.00000 | 23.19179 | 32.39356 | -0.7865 | 21.24851 |
October | 340.00000 | 22.19852 | 23.88091 | -0.1575 | 6.96728 |
November | 330.00000 | 21.20777 | 18.04482 | -0.4968 | 10.57276 |
December | 338.00000 | 21.10982 | 13.59438 | -0.6308 | 13.57005 |
Annual Sum or Average | 4030.00000 | 22.18730 | 22.69720 | -0.6107 | 15.14115 |
Minimum of Months | 308.00000 | 21.10982 | 11.07410 | -1.2772 | 6.96728 |
Maximum of Months | 348.00000 | 23.90648 | 33.92288 | -0.1575 | 41.51919 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10949 | 11.01563 | -0.6894 | 15.23579 |
February | 308.00000 | 21.20512 | 13.98248 | -0.5941 | 12.83883 |
March | 348.00000 | 21.12385 | 16.23114 | -0.5663 | 11.90370 |
April | 330.00000 | 21.63676 | 21.08385 | -0.3915 | 9.11488 |
May | 344.00000 | 22.35252 | 24.55842 | -1.2556 | 40.51384 |
June | 336.00000 | 23.71852 | 31.53341 | -0.6569 | 15.07863 |
July | 338.00000 | 23.92813 | 33.87047 | -0.5133 | 10.80416 |
August | 348.00000 | 23.84520 | 30.91916 | -0.5666 | 12.28651 |
September | 330.00000 | 23.32008 | 32.18796 | -0.7737 | 20.52874 |
October | 340.00000 | 22.41046 | 23.64576 | -0.1303 | 6.91389 |
November | 330.00000 | 21.28710 | 17.88145 | -0.4908 | 10.54535 |
December | 338.00000 | 21.10974 | 13.53180 | -0.6317 | 13.57579 |
Annual Sum or Average | 4030.00000 | 22.26282 | 22.59197 | -0.6060 | 14.98993 |
Minimum of Months | 308.00000 | 21.10949 | 11.01563 | -1.2556 | 6.91389 |
Maximum of Months | 348.00000 | 23.92813 | 33.87047 | -0.1303 | 40.51384 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10984 | 11.01549 | -0.6929 | 15.33360 |
February | 308.00000 | 21.19811 | 13.98844 | -0.6001 | 12.96897 |
March | 348.00000 | 21.12151 | 16.23392 | -0.5719 | 12.03563 |
April | 330.00000 | 21.61171 | 21.11402 | -0.4021 | 9.26482 |
May | 344.00000 | 22.32748 | 24.60051 | -1.2699 | 41.15988 |
June | 336.00000 | 23.70636 | 31.56914 | -0.6660 | 15.36100 |
July | 338.00000 | 23.92619 | 33.88353 | -0.5182 | 10.91447 |
August | 348.00000 | 23.84151 | 30.93858 | -0.5718 | 12.42452 |
September | 330.00000 | 23.30669 | 32.21971 | -0.7816 | 20.81398 |
October | 340.00000 | 22.38518 | 23.68588 | -0.1384 | 6.95546 |
November | 330.00000 | 21.27449 | 17.89759 | -0.4975 | 10.66944 |
December | 338.00000 | 21.10982 | 13.53194 | -0.6361 | 13.69081 |
Annual Sum or Average | 4030.00000 | 22.25218 | 22.61179 | -0.6132 | 15.17833 |
Minimum of Months | 308.00000 | 21.10982 | 11.01549 | -1.2699 | 6.95546 |
Maximum of Months | 348.00000 | 23.92619 | 33.88353 | -0.1384 | 41.15988 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10992 | 11.01576 | -0.7059 | 15.71215 |
February | 308.00000 | 21.17793 | 14.00451 | -0.6196 | 13.42080 |
March | 348.00000 | 21.11554 | 16.24068 | -0.5895 | 12.46276 |
April | 330.00000 | 21.53681 | 21.20095 | -0.4343 | 9.74186 |
May | 344.00000 | 22.23958 | 24.72780 | -1.3163 | 43.28995 |
June | 336.00000 | 23.64941 | 31.68600 | -0.6976 | 16.44100 |
July | 338.00000 | 23.91823 | 33.92516 | -0.5284 | 11.16362 |
August | 348.00000 | 23.82542 | 30.97348 | -0.5846 | 12.81903 |
September | 330.00000 | 23.25301 | 32.32508 | -0.8072 | 21.83239 |
October | 340.00000 | 22.28459 | 23.82187 | -0.1687 | 7.11308 |
November | 330.00000 | 21.23765 | 17.94449 | -0.5171 | 11.04121 |
December | 338.00000 | 21.10979 | 13.53248 | -0.6504 | 14.08046 |
Annual Sum or Average | 4030.00000 | 22.21378 | 22.67184 | -0.6359 | 15.80739 |
Minimum of Months | 308.00000 | 21.10979 | 11.01576 | -1.3163 | 7.11308 |
Maximum of Months | 348.00000 | 23.91823 | 33.92516 | -0.1687 | 43.28995 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.10994 | 10.90675 | -0.7656 | 17.59476 |
February | 308.00000 | 21.15196 | 13.93249 | -0.6872 | 15.26485 |
March | 348.00000 | 21.10993 | 16.09841 | -0.6556 | 14.22834 |
April | 330.00000 | 21.41524 | 21.19646 | -0.5198 | 11.35720 |
May | 344.00000 | 22.08652 | 24.78278 | -1.4286 | 48.55509 |
June | 336.00000 | 23.50909 | 31.74849 | -0.7818 | 19.55826 |
July | 338.00000 | 23.89396 | 34.04860 | -0.5513 | 11.82022 |
August | 348.00000 | 23.78487 | 30.75561 | -0.6156 | 13.89279 |
September | 330.00000 | 23.15547 | 32.37208 | -0.8630 | 24.21725 |
October | 340.00000 | 22.12110 | 23.76058 | -0.2317 | 7.65553 |
November | 330.00000 | 21.19236 | 17.91502 | -0.5699 | 12.23615 |
December | 338.00000 | 21.10994 | 13.44627 | -0.7074 | 15.74372 |
Annual Sum or Average | 4030.00000 | 22.14558 | 22.63497 | -0.6990 | 17.72741 |
Minimum of Months | 308.00000 | 21.10993 | 10.90675 | -1.4286 | 7.65553 |
Maximum of Months | 348.00000 | 23.89396 | 34.04860 | -0.2317 | 48.55509 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 517.58 | 146.30 | 1.50 | 517.58 | 0.00 | 0.00 | 0.00 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 | 0.15 | 27-FEB-15:30 | 0.15 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 | 0.04 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 36535100.73 | 10114761.85 | 14.91 | 36535100.73 | 0.00 | 0.00 | 0.28 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 3292.22 | 07-APR-14:00 | 3292.22 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 901.15 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.144806E+10 | 0.378004E+09 | 115.35 | 0.143719E+10 | 10866266.23 | 0.00 | 0.88 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 | 12347.37 | 20-MAY-16:10 | 12347.37 | 20-MAY-16:10 | 296.91 | 20-MAY-11:00 | 3235.96 | 20-MAY-16:10 | 0.00 | 01-MAY-00:10 |
June | 0.634181E+10 | 0.162021E+10 | 296.34 | 0.601172E+10 | 0.330088E+09 | 0.00 | 1.00 | 28-JUN-16:20 | 0.00 | 01-JUN-00:10 | 15773.47 | 20-JUN-17:00 | 15251.81 | 23-JUN-14:00 | 3429.21 | 22-JUN-07:03 | 4059.76 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.129984E+11 | 0.335819E+10 | 429.86 | 0.125997E+11 | 0.398738E+09 | 0.00 | 1.00 | 17-JUL-07:02 | 0.00 | 01-JUL-00:05 | 32430.16 | 19-JUL-07:03 | 29016.24 | 18-JUL-07:03 | 10666.15 | 19-JUL-07:03 | 6898.94 | 19-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.105700E+11 | 0.273369E+10 | 400.00 | 0.104825E+11 | 87494023.26 | 0.00 | 1.00 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 29776.03 | 07-AUG-07:02 | 29776.03 | 07-AUG-07:02 | 2209.43 | 09-AUG-07:03 | 6497.21 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.578338E+10 | 0.146595E+10 | 239.38 | 0.543364E+10 | 0.349734E+09 | 0.00 | 1.00 | 04-SEP-07:02 | 0.00 | 01-SEP-00:10 | 30117.99 | 05-SEP-07:02 | 28684.05 | 04-SEP-07:02 | 10030.83 | 07-SEP-07:02 | 6397.32 | 05-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 0.584933E+09 | 0.150603E+09 | 70.53 | 0.584933E+09 | 2.35 | 0.00 | 0.76 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 10214.84 | 18-OCT-14:00 | 10214.84 | 18-OCT-14:00 | 0.00 | 13-OCT-17:20 | 2517.72 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.377632E+11 | 0.971677E+10 | 1567.87 | 0.365862E+11 | 0.117692E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.129984E+11 | 0.335819E+10 | 429.86 | 0.125997E+11 | 0.398738E+09 | 0.00 | 1.00 | 0.00 | 32430.16 | 29776.03 | 10666.15 | 6898.94 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 1475374.14 | 406776.77 | 8.25 | 1475374.14 | 0.00 | 0.00 | 0.08 | 28-FEB-22:40 | 0.00 | 01-FEB-00:05 | 444.46 | 28-FEB-22:40 | 444.46 | 28-FEB-22:40 | 0.00 | 20-FEB-22:10 | 122.24 | 28-FEB-22:40 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 83060944.73 | 18647870.14 | 40.23 | 83060944.73 | 0.00 | 0.00 | 1.00 | 06-APR-20:02 | 0.00 | 01-APR-00:05 | 16354.29 | 06-APR-20:02 | 16354.29 | 06-APR-20:02 | 0.00 | 07-APR-12:40 | 3194.75 | 06-APR-20:02 | 0.00 | 01-APR-00:05 |
May | 0.125384E+10 | 0.270870E+09 | 129.79 | 0.124679E+10 | 7057095.65 | 0.00 | 1.00 | 02-MAY-20:31 | 0.00 | 01-MAY-00:10 | 16666.00 | 20-MAY-18:17 | 16666.00 | 20-MAY-18:17 | 2833.63 | 20-MAY-21:20 | 3427.51 | 20-MAY-18:17 | 0.00 | 01-MAY-00:10 |
June | 0.441773E+10 | 0.961115E+09 | 289.65 | 0.425782E+10 | 0.159916E+09 | 0.00 | 1.00 | 03-JUN-18:01 | 0.00 | 01-JUN-00:10 | 17452.78 | 21-JUN-20:02 | 16676.91 | 25-JUN-17:47 | 5239.02 | 21-JUN-22:39 | 3523.10 | 18-JUN-19:11 | 0.00 | 01-JUN-00:10 |
July | 0.828962E+10 | 0.184745E+10 | 377.29 | 0.809720E+10 | 0.192420E+09 | 0.00 | 1.00 | 01-JUL-18:02 | 0.00 | 01-JUL-00:05 | 17939.93 | 18-JUL-22:00 | 16849.23 | 18-JUL-07:03 | 7548.54 | 18-JUL-22:00 | 3516.23 | 18-JUL-20:02 | 0.00 | 01-JUL-00:05 |
August | 0.686328E+10 | 0.152683E+10 | 351.53 | 0.682824E+10 | 35047507.61 | 0.00 | 1.00 | 02-AUG-21:02 | 0.00 | 01-AUG-00:10 | 16891.10 | 08-AUG-22:44 | 16582.10 | 07-AUG-22:01 | 3553.17 | 15-AUG-20:30 | 3449.77 | 08-AUG-22:01 | 0.00 | 01-AUG-00:10 |
September | 0.370729E+10 | 0.810363E+09 | 229.53 | 0.353520E+10 | 0.172094E+09 | 0.00 | 1.00 | 01-SEP-20:01 | 0.00 | 01-SEP-00:10 | 17733.61 | 06-SEP-20:02 | 16646.72 | 24-SEP-17:17 | 6310.66 | 06-SEP-23:00 | 3489.60 | 06-SEP-20:02 | 0.00 | 01-SEP-00:10 |
October | 0.444489E+09 | 97484675.99 | 102.08 | 0.444489E+09 | 0.00 | 0.00 | 1.00 | 02-OCT-20:02 | 0.00 | 01-OCT-00:10 | 16354.29 | 02-OCT-20:02 | 16354.29 | 02-OCT-20:02 | 0.00 | 15-OCT-14:10 | 3194.75 | 02-OCT-20:02 | 0.00 | 01-OCT-00:10 |
November | 6215933.25 | 1471936.13 | 15.88 | 6215933.25 | 0.00 | 0.00 | 1.00 | 04-NOV-19:22 | 0.00 | 01-NOV-00:10 | 16354.29 | 04-NOV-19:22 | 16354.29 | 04-NOV-19:22 | 0.00 | 03-NOV-14:30 | 3194.75 | 04-NOV-19:22 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.250670E+11 | 0.553464E+10 | 1544.24 | 0.245005E+11 | 0.566535E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.828962E+10 | 0.184745E+10 | 377.29 | 0.809720E+10 | 0.192420E+09 | 0.00 | 1.00 | 0.00 | 17939.93 | 16849.23 | 7548.54 | 3523.10 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 1661.22 | 409.42 | 6.33 | 1661.22 | 0.00 | 0.00 | 0.00 | 27-FEB-11:50 | 0.00 | 01-FEB-00:05 | 0.17 | 27-FEB-11:50 | 0.17 | 27-FEB-11:50 | 0.00 | 26-FEB-14:40 | 0.04 | 27-FEB-11:50 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 47467491.99 | 11158861.04 | 32.17 | 47467491.99 | 0.00 | 0.00 | 0.42 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 3148.49 | 07-APR-14:00 | 3148.49 | 07-APR-14:00 | 0.00 | 07-APR-13:20 | 722.64 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.767575E+09 | 0.172204E+09 | 110.39 | 0.766677E+09 | 898389.79 | 0.00 | 0.88 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 7612.71 | 20-MAY-16:00 | 7612.71 | 20-MAY-16:00 | 73.19 | 28-MAY-10:30 | 1742.11 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.321566E+10 | 0.714714E+09 | 252.97 | 0.312020E+10 | 95463450.62 | 0.00 | 1.00 | 29-JUN-12:40 | 0.00 | 01-JUN-00:10 | 12503.20 | 22-JUN-06:03 | 9062.97 | 23-JUN-14:00 | 3955.02 | 22-JUN-06:03 | 2396.51 | 22-JUN-06:03 | 0.00 | 01-JUN-00:10 |
July | 0.621007E+10 | 0.140416E+10 | 313.12 | 0.610376E+10 | 0.106312E+09 | 0.00 | 1.00 | 16-JUL-07:02 | 0.00 | 01-JUL-00:05 | 17896.81 | 19-JUL-06:03 | 15770.53 | 26-JUL-06:03 | 5762.20 | 19-JUL-06:03 | 3507.89 | 19-JUL-06:03 | 0.00 | 01-JUL-00:05 |
August | 0.513884E+10 | 0.116113E+10 | 295.90 | 0.512097E+10 | 17861834.13 | 0.00 | 1.00 | 07-AUG-06:02 | 0.00 | 01-AUG-00:10 | 16573.33 | 06-AUG-07:03 | 16573.33 | 06-AUG-07:03 | 2480.72 | 01-AUG-06:02 | 3261.55 | 06-AUG-07:03 | 0.00 | 01-AUG-00:10 |
September | 0.261045E+10 | 0.578124E+09 | 197.28 | 0.248991E+10 | 0.120540E+09 | 0.00 | 1.00 | 03-SEP-07:02 | 0.00 | 01-SEP-00:10 | 17150.13 | 07-SEP-06:02 | 16454.03 | 03-SEP-07:02 | 6251.49 | 07-SEP-06:02 | 3368.82 | 07-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.348474E+09 | 77594571.40 | 92.30 | 0.348474E+09 | 0.00 | 0.00 | 0.79 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 6534.93 | 18-OCT-14:00 | 6534.93 | 18-OCT-14:00 | 0.00 | 18-OCT-13:40 | 1393.06 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 15855.87 | 3904.91 | 7.33 | 15855.87 | 0.00 | 0.00 | 0.00 | 04-NOV-11:30 | 0.00 | 01-NOV-00:10 | 23.18 | 04-NOV-11:30 | 23.18 | 04-NOV-11:30 | 0.00 | 04-NOV-15:40 | 5.71 | 04-NOV-11:30 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.183385E+11 | 0.411909E+10 | 1307.80 | 0.179975E+11 | 0.341075E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.621007E+10 | 0.140416E+10 | 313.12 | 0.610376E+10 | 0.120540E+09 | 0.00 | 1.00 | 0.00 | 17896.81 | 16573.33 | 6251.49 | 3507.89 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 909.54 | 224.17 | 4.50 | 909.54 | 0.00 | 0.00 | 0.00 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 | 0.13 | 27-FEB-15:30 | 0.13 | 27-FEB-15:30 | 0.00 | 27-FEB-16:00 | 0.03 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 41079181.07 | 9701699.62 | 30.67 | 41079181.07 | 0.00 | 0.00 | 0.40 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 2994.38 | 07-APR-14:00 | 2994.38 | 07-APR-14:00 | 0.00 | 07-APR-14:10 | 691.11 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.742872E+09 | 0.167160E+09 | 108.26 | 0.742060E+09 | 811698.19 | 0.00 | 0.88 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 7559.91 | 20-MAY-16:00 | 7559.91 | 20-MAY-16:00 | 68.00 | 19-MAY-11:00 | 1734.15 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.319541E+10 | 0.711109E+09 | 250.59 | 0.310085E+10 | 94563347.00 | 0.00 | 1.00 | 23-JUN-13:20 | 0.00 | 01-JUN-00:10 | 12319.97 | 22-JUN-06:03 | 9062.24 | 23-JUN-14:00 | 3892.47 | 22-JUN-06:03 | 2357.34 | 22-JUN-06:03 | 0.00 | 01-JUN-00:10 |
July | 0.622822E+10 | 0.140850E+10 | 312.37 | 0.612123E+10 | 0.106986E+09 | 0.00 | 1.00 | 16-JUL-07:02 | 0.00 | 01-JUL-00:05 | 17967.20 | 19-JUL-06:03 | 16121.69 | 26-JUL-06:03 | 5776.55 | 19-JUL-06:03 | 3521.66 | 19-JUL-06:03 | 0.00 | 01-JUL-00:05 |
August | 0.514620E+10 | 0.116313E+10 | 295.16 | 0.512837E+10 | 17833683.77 | 0.00 | 1.00 | 06-AUG-07:03 | 0.00 | 01-AUG-00:10 | 16724.16 | 06-AUG-07:03 | 16724.16 | 06-AUG-07:03 | 2655.72 | 01-AUG-06:02 | 3292.38 | 06-AUG-07:03 | 0.00 | 01-AUG-00:10 |
September | 0.260312E+10 | 0.576784E+09 | 193.40 | 0.248224E+10 | 0.120874E+09 | 0.00 | 1.00 | 03-SEP-07:02 | 0.00 | 01-SEP-00:10 | 17217.71 | 07-SEP-06:02 | 16531.65 | 03-SEP-07:02 | 6269.72 | 07-SEP-06:02 | 3382.11 | 07-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.325677E+09 | 72694086.30 | 86.20 | 0.325677E+09 | 0.00 | 0.00 | 0.78 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 6442.51 | 18-OCT-14:00 | 6442.51 | 18-OCT-14:00 | 0.00 | 18-OCT-13:30 | 1378.23 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 1256.77 | 309.74 | 5.17 | 1256.77 | 0.00 | 0.00 | 0.00 | 04-NOV-14:00 | 0.00 | 01-NOV-00:10 | 0.18 | 04-NOV-14:00 | 0.18 | 04-NOV-14:00 | 0.00 | 04-NOV-13:40 | 0.05 | 04-NOV-14:00 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.182826E+11 | 0.410908E+10 | 1286.31 | 0.179415E+11 | 0.341069E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.622822E+10 | 0.140850E+10 | 312.37 | 0.612123E+10 | 0.120874E+09 | 0.00 | 1.00 | 0.00 | 17967.20 | 16724.16 | 6269.72 | 3521.66 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 575.71 | 141.89 | 2.67 | 575.71 | 0.00 | 0.00 | 0.00 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 | 0.11 | 27-FEB-15:30 | 0.11 | 27-FEB-15:30 | 0.00 | 27-FEB-14:40 | 0.03 | 27-FEB-15:30 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 29531651.48 | 7037922.15 | 27.17 | 29531651.48 | 0.00 | 0.00 | 0.36 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 2618.87 | 07-APR-14:00 | 2618.87 | 07-APR-14:00 | 0.00 | 07-APR-14:10 | 611.54 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.673444E+09 | 0.152536E+09 | 101.23 | 0.672829E+09 | 615067.11 | 0.00 | 0.86 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 7304.06 | 20-MAY-16:00 | 7304.06 | 20-MAY-16:00 | 58.75 | 19-MAY-11:00 | 1683.91 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.305442E+10 | 0.682272E+09 | 244.44 | 0.296445E+10 | 89978182.24 | 0.00 | 1.00 | 29-JUN-13:50 | 0.00 | 01-JUN-00:10 | 9506.61 | 22-JUN-06:03 | 8883.53 | 23-JUN-14:00 | 2965.34 | 22-JUN-06:03 | 2060.50 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.604363E+10 | 0.137010E+10 | 310.18 | 0.594141E+10 | 0.102225E+09 | 0.00 | 1.00 | 16-JUL-07:02 | 0.00 | 01-JUL-00:05 | 17762.28 | 19-JUL-06:03 | 15593.77 | 18-JUL-06:02 | 5739.80 | 19-JUL-06:03 | 3481.61 | 19-JUL-06:03 | 0.00 | 01-JUL-00:05 |
August | 0.497750E+10 | 0.112763E+10 | 291.41 | 0.496123E+10 | 16262955.32 | 0.00 | 1.00 | 07-AUG-06:02 | 0.00 | 01-AUG-00:10 | 16367.37 | 07-AUG-06:02 | 16367.37 | 07-AUG-06:02 | 2456.37 | 09-AUG-06:02 | 3197.31 | 07-AUG-06:02 | 0.00 | 01-AUG-00:10 |
September | 0.250109E+10 | 0.555364E+09 | 185.18 | 0.238375E+10 | 0.117348E+09 | 0.00 | 1.00 | 03-SEP-07:02 | 0.00 | 01-SEP-00:10 | 17021.44 | 07-SEP-06:02 | 16320.50 | 03-SEP-07:02 | 6224.76 | 07-SEP-06:02 | 3343.52 | 07-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.283255E+09 | 63536327.12 | 75.42 | 0.283255E+09 | 0.00 | 0.00 | 0.76 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 | 6159.81 | 18-OCT-14:00 | 6159.81 | 18-OCT-14:00 | 0.00 | 18-OCT-13:10 | 1326.26 | 18-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 5099.40 | 1256.54 | 4.33 | 5099.40 | 0.00 | 0.00 | 0.00 | 04-NOV-12:30 | 0.00 | 01-NOV-00:10 | 6.82 | 04-NOV-12:30 | 6.82 | 04-NOV-12:30 | 0.00 | 01-NOV-00:10 | 1.68 | 04-NOV-12:30 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.175629E+11 | 0.395847E+10 | 1242.03 | 0.172365E+11 | 0.326430E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.604363E+10 | 0.137010E+10 | 310.18 | 0.594141E+10 | 0.117348E+09 | 0.00 | 1.00 | 0.00 | 17762.28 | 16367.37 | 6224.76 | 3481.61 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 14472416.40 | 4061066.72 | 6.17 | 14472416.40 | 0.00 | 0.00 | 0.20 | 07-APR-14:10 | 0.00 | 01-APR-00:05 | 2201.40 | 07-APR-14:10 | 2201.40 | 07-APR-14:10 | 0.00 | 07-APR-14:50 | 612.71 | 07-APR-14:10 | 0.00 | 01-APR-00:05 |
May | 0.850632E+09 | 0.226073E+09 | 65.50 | 0.845525E+09 | 5106733.71 | 0.00 | 0.83 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 11222.10 | 20-MAY-16:00 | 11222.10 | 20-MAY-16:00 | 291.95 | 20-MAY-11:00 | 2986.48 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.461905E+10 | 0.119660E+10 | 215.01 | 0.438934E+10 | 0.229712E+09 | 0.00 | 1.00 | 29-JUN-12:50 | 0.00 | 01-JUN-00:10 | 14447.79 | 29-JUN-15:00 | 14447.79 | 29-JUN-15:00 | 3387.56 | 22-JUN-07:03 | 3866.29 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.946307E+10 | 0.247283E+10 | 305.12 | 0.920463E+10 | 0.258435E+09 | 0.00 | 1.00 | 16-JUL-08:62 | 0.00 | 01-JUL-00:05 | 31179.63 | 19-JUL-07:03 | 29367.65 | 18-JUL-07:03 | 9633.18 | 19-JUL-07:03 | 6639.56 | 19-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.782306E+10 | 0.204192E+10 | 291.20 | 0.776266E+10 | 60394243.94 | 0.00 | 1.00 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 | 29240.19 | 06-AUG-08:62 | 29240.19 | 06-AUG-08:62 | 3392.84 | 01-AUG-07:02 | 6526.28 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.393415E+10 | 0.100141E+10 | 158.81 | 0.366262E+10 | 0.271531E+09 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 29291.39 | 06-SEP-07:02 | 29219.62 | 04-SEP-08:62 | 10351.69 | 07-SEP-07:02 | 6752.21 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.357721E+09 | 93562584.30 | 42.17 | 0.357721E+09 | 0.00 | 0.00 | 0.70 | 18-OCT-14:30 | 0.00 | 01-OCT-00:10 | 8856.70 | 18-OCT-14:30 | 8856.70 | 18-OCT-14:30 | 0.00 | 18-OCT-15:10 | 2227.24 | 18-OCT-14:30 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.270622E+11 | 0.703646E+10 | 1083.97 | 0.262370E+11 | 0.825179E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.946307E+10 | 0.247283E+10 | 305.12 | 0.920463E+10 | 0.271531E+09 | 0.00 | 1.00 | 0.00 | 31179.63 | 29367.65 | 10351.69 | 6752.21 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 676217.84 | 165102.50 | 0.83 | 676217.84 | 0.00 | 0.00 | 0.04 | 27-FEB-15:20 | 0.00 | 01-FEB-00:05 | 251.86 | 27-FEB-15:20 | 251.86 | 27-FEB-15:20 | 0.00 | 01-FEB-00:05 | 61.43 | 27-FEB-15:20 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 48183032.35 | 11454500.11 | 16.50 | 48183032.35 | 0.00 | 0.00 | 0.29 | 07-APR-14:10 | 0.00 | 01-APR-00:05 | 1893.52 | 07-APR-14:10 | 1893.52 | 07-APR-14:10 | 0.00 | 07-APR-15:00 | 447.72 | 07-APR-14:10 | 0.00 | 01-APR-00:05 |
May | 0.716223E+09 | 0.164551E+09 | 93.58 | 0.716192E+09 | 30438.16 | 0.00 | 0.84 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 6395.55 | 20-MAY-16:00 | 6395.55 | 20-MAY-16:00 | 11.63 | 30-MAY-09:50 | 1479.96 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.322498E+10 | 0.727357E+09 | 275.97 | 0.312781E+10 | 97165454.59 | 0.00 | 1.00 | 23-JUN-13:50 | 0.00 | 01-JUN-00:10 | 8016.82 | 29-JUN-15:00 | 8016.82 | 29-JUN-15:00 | 1173.43 | 20-JUN-15:20 | 1881.04 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.582918E+10 | 0.132845E+10 | 345.35 | 0.573130E+10 | 97876784.24 | 0.00 | 1.00 | 16-JUL-08:62 | 0.00 | 01-JUL-00:05 | 16014.74 | 19-JUL-07:03 | 15132.28 | 17-JUL-07:02 | 2789.22 | 19-JUL-07:03 | 3145.69 | 19-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.513629E+10 | 0.116678E+10 | 339.69 | 0.511785E+10 | 18442117.47 | 0.00 | 1.00 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 | 15219.57 | 08-AUG-07:03 | 15219.57 | 08-AUG-07:03 | 412.30 | 22-AUG-14:30 | 3108.38 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.280434E+10 | 0.623808E+09 | 208.30 | 0.267247E+10 | 0.131874E+09 | 0.00 | 1.00 | 03-SEP-08:62 | 0.00 | 01-SEP-00:10 | 15977.66 | 07-SEP-07:02 | 15386.20 | 05-SEP-07:02 | 2830.64 | 07-SEP-07:02 | 3195.98 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.457255E+09 | 0.103348E+09 | 70.11 | 0.457255E+09 | 0.00 | 0.00 | 0.72 | 18-OCT-14:30 | 0.00 | 01-OCT-00:10 | 5265.35 | 18-OCT-14:40 | 5265.35 | 18-OCT-14:40 | 0.00 | 18-OCT-15:20 | 1144.27 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.182171E+11 | 0.412591E+10 | 1350.34 | 0.178717E+11 | 0.345388E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.582918E+10 | 0.132845E+10 | 345.35 | 0.573130E+10 | 0.131874E+09 | 0.00 | 1.00 | 0.00 | 16014.74 | 15386.20 | 2830.64 | 3195.98 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 245109.95 | 60150.20 | 0.67 | 245109.95 | 0.00 | 0.00 | 0.02 | 27-FEB-15:40 | 0.00 | 01-FEB-00:05 | 114.54 | 27-FEB-15:40 | 114.54 | 27-FEB-15:40 | 0.00 | 27-FEB-15:40 | 28.09 | 27-FEB-15:40 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 42852589.04 | 10209412.60 | 14.17 | 42852589.04 | 0.00 | 0.00 | 0.29 | 07-APR-14:10 | 0.00 | 01-APR-00:05 | 1809.99 | 07-APR-14:10 | 1809.99 | 07-APR-14:10 | 0.00 | 07-APR-14:10 | 429.08 | 07-APR-14:10 | 0.00 | 01-APR-00:05 |
May | 0.680621E+09 | 0.156674E+09 | 89.00 | 0.680584E+09 | 37314.43 | 0.00 | 0.84 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 6294.30 | 20-MAY-16:00 | 6294.30 | 20-MAY-16:00 | 11.81 | 19-MAY-12:00 | 1458.58 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.313344E+10 | 0.707524E+09 | 269.82 | 0.303760E+10 | 95844421.72 | 0.00 | 1.00 | 29-JUN-15:20 | 0.00 | 01-JUN-00:10 | 7935.97 | 29-JUN-15:00 | 7935.97 | 29-JUN-15:00 | 1164.17 | 20-JUN-15:20 | 1861.75 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.573374E+10 | 0.130778E+10 | 344.13 | 0.563715E+10 | 96591839.83 | 0.00 | 1.00 | 16-JUL-08:62 | 0.00 | 01-JUL-00:05 | 15863.56 | 19-JUL-07:03 | 14960.27 | 17-JUL-07:02 | 2793.47 | 19-JUL-07:03 | 3116.17 | 19-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.504555E+10 | 0.114713E+10 | 338.04 | 0.502728E+10 | 18262593.26 | 0.00 | 1.00 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 | 15065.36 | 08-AUG-07:03 | 15065.36 | 08-AUG-07:03 | 409.80 | 22-AUG-14:30 | 3078.22 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.274846E+10 | 0.611769E+09 | 205.21 | 0.261800E+10 | 0.130455E+09 | 0.00 | 1.00 | 03-SEP-08:62 | 0.00 | 01-SEP-00:10 | 15828.09 | 07-SEP-07:02 | 15238.28 | 05-SEP-07:02 | 2836.96 | 07-SEP-07:02 | 3165.07 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.436351E+09 | 98752779.14 | 68.75 | 0.436351E+09 | 0.00 | 0.00 | 0.72 | 18-OCT-14:30 | 0.00 | 01-OCT-00:10 | 5179.09 | 18-OCT-14:40 | 5179.09 | 18-OCT-14:40 | 0.00 | 18-OCT-11:40 | 1127.00 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.178213E+11 | 0.403990E+10 | 1329.78 | 0.174801E+11 | 0.341192E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.573374E+10 | 0.130778E+10 | 344.13 | 0.563715E+10 | 0.130455E+09 | 0.00 | 1.00 | 0.00 | 15863.56 | 15238.28 | 2836.96 | 3165.07 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 29290976.72 | 7038557.17 | 11.33 | 29290976.72 | 0.00 | 0.00 | 0.25 | 07-APR-14:10 | 0.00 | 01-APR-00:05 | 1521.39 | 07-APR-14:10 | 1521.39 | 07-APR-14:10 | 0.00 | 07-APR-13:40 | 364.56 | 07-APR-14:10 | 0.00 | 01-APR-00:05 |
May | 0.583872E+09 | 0.135368E+09 | 78.00 | 0.583837E+09 | 34922.70 | 0.00 | 0.82 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 6042.43 | 20-MAY-16:00 | 6042.43 | 20-MAY-16:00 | 11.87 | 19-MAY-12:00 | 1408.69 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.288833E+10 | 0.655088E+09 | 252.39 | 0.279755E+10 | 90784006.31 | 0.00 | 1.00 | 29-JUN-13:00 | 0.00 | 01-JUN-00:10 | 7766.99 | 29-JUN-15:00 | 7766.99 | 29-JUN-15:00 | 1134.38 | 20-JUN-15:20 | 1819.77 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.551650E+10 | 0.126176E+10 | 339.07 | 0.542479E+10 | 91718453.37 | 0.00 | 1.00 | 16-JUL-08:62 | 0.00 | 01-JUL-00:05 | 15378.38 | 16-JUL-08:62 | 14712.33 | 18-JUL-07:03 | 2696.77 | 19-JUL-07:03 | 3065.70 | 17-JUL-07:02 | 0.00 | 01-JUL-00:05 |
August | 0.483572E+10 | 0.110242E+10 | 330.70 | 0.481851E+10 | 17212877.29 | 0.00 | 1.00 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 | 14666.74 | 07-AUG-07:02 | 14666.74 | 07-AUG-07:02 | 397.30 | 22-AUG-14:30 | 2982.08 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.260891E+10 | 0.582038E+09 | 198.19 | 0.248198E+10 | 0.126932E+09 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 15294.38 | 06-SEP-07:02 | 15043.26 | 05-SEP-07:02 | 2659.32 | 07-SEP-15:00 | 3124.08 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.373610E+09 | 84979821.43 | 62.33 | 0.373610E+09 | 0.00 | 0.00 | 0.70 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 | 4925.96 | 18-OCT-14:40 | 4925.96 | 18-OCT-14:40 | 0.00 | 18-OCT-13:30 | 1079.25 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.168362E+11 | 0.382869E+10 | 1272.01 | 0.165096E+11 | 0.326683E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.551650E+10 | 0.126176E+10 | 339.07 | 0.542479E+10 | 0.126932E+09 | 0.00 | 1.00 | 0.00 | 15378.38 | 15043.26 | 2696.77 | 3124.08 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 802547.46 | 202381.82 | 0.83 | 802547.46 | 0.00 | 0.00 | 0.07 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 459.22 | 07-APR-14:00 | 459.22 | 07-APR-14:00 | 0.00 | 01-APR-00:05 | 115.77 | 07-APR-14:00 | 0.00 | 01-APR-00:05 |
May | 0.364570E+09 | 86707851.38 | 52.75 | 0.364367E+09 | 203368.41 | 0.00 | 0.73 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 | 5800.39 | 20-MAY-16:00 | 5800.39 | 20-MAY-16:00 | 32.17 | 19-MAY-11:30 | 1391.44 | 20-MAY-16:00 | 0.00 | 01-MAY-00:10 |
June | 0.225718E+10 | 0.522895E+09 | 194.58 | 0.217738E+10 | 79799422.33 | 0.00 | 0.94 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 | 7728.11 | 29-JUN-15:00 | 7728.11 | 29-JUN-15:00 | 1127.61 | 20-JUN-15:30 | 1844.33 | 29-JUN-15:00 | 0.00 | 01-JUN-00:10 |
July | 0.499083E+10 | 0.115924E+10 | 288.43 | 0.490560E+10 | 85232372.49 | 0.00 | 1.00 | 15-JUL-15:20 | 0.00 | 01-JUL-00:05 | 16457.47 | 17-JUL-07:02 | 14981.17 | 17-JUL-07:02 | 1913.36 | 16-JUL-08:62 | 3333.78 | 17-JUL-07:02 | 0.00 | 01-JUL-00:05 |
August | 0.406937E+10 | 0.943369E+09 | 272.08 | 0.405818E+10 | 11182711.32 | 0.00 | 1.00 | 05-AUG-12:50 | 0.00 | 01-AUG-00:10 | 13812.57 | 07-AUG-07:02 | 13812.57 | 07-AUG-07:02 | 408.81 | 22-AUG-14:20 | 2751.27 | 07-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.193289E+10 | 0.437410E+09 | 139.23 | 0.183439E+10 | 98495710.61 | 0.00 | 1.00 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 | 16288.68 | 04-SEP-08:62 | 16288.68 | 04-SEP-08:62 | 3527.20 | 07-SEP-14:50 | 3473.11 | 04-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.129964E+09 | 30026191.97 | 37.92 | 0.129964E+09 | 0.00 | 0.00 | 0.62 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 | 4732.49 | 18-OCT-14:40 | 4732.49 | 18-OCT-14:40 | 0.00 | 18-OCT-13:20 | 1062.17 | 18-OCT-14:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.137456E+11 | 0.317985E+10 | 985.82 | 0.134707E+11 | 0.274914E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.499083E+10 | 0.115924E+10 | 288.43 | 0.490560E+10 | 98495710.61 | 0.00 | 1.00 | 0.00 | 16457.47 | 16288.68 | 3527.20 | 3473.11 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.86 | 119.34 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.92 | 88.64 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.82 | 77.88 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.48 | 56.54 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 73.90 | 45.24 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.61 | 31.97 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.04 | 25.21 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.52 | 28.72 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.08 | 41.14 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.45 | 59.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 130.82 | 74.83 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.92 | 102.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.38 | 62.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 73.90 | 25.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.45 | 119.34 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.86 | 119.34 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.92 | 88.64 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.82 | 77.88 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.48 | 56.54 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 73.90 | 45.24 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.61 | 31.97 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.04 | 25.21 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.52 | 28.72 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.08 | 41.14 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.45 | 59.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 130.82 | 74.83 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.92 | 102.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.38 | 62.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 73.90 | 25.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.45 | 119.34 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.86 | 119.34 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.92 | 88.64 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.82 | 77.88 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.48 | 56.54 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 73.90 | 45.24 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.61 | 31.97 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.04 | 25.21 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.52 | 28.72 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.08 | 41.14 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.45 | 59.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 130.82 | 74.83 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.92 | 102.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.38 | 62.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 73.90 | 25.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.45 | 119.34 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.86 | 119.34 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.92 | 88.64 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.82 | 77.88 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.48 | 56.54 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 73.90 | 45.24 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.61 | 31.97 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.04 | 25.21 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.52 | 28.72 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.08 | 41.14 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.45 | 59.11 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 130.82 | 74.83 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.92 | 102.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.38 | 62.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 73.90 | 25.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.45 | 119.34 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 142.04 | 101.44 | 40.61 | 131.29 | 142.37 | 0.00 | 0.00 | 744.00 |
February | 180.96 | 130.15 | 50.80 | 178.29 | 105.81 | 0.00 | 0.00 | 672.00 |
March | 161.82 | 90.90 | 70.92 | 149.25 | 92.98 | 0.00 | 0.00 | 744.00 |
April | 130.03 | 62.20 | 67.83 | 110.24 | 67.56 | 0.00 | 0.00 | 720.00 |
May | 115.50 | 38.35 | 77.15 | 89.06 | 54.06 | 0.00 | 0.00 | 744.00 |
June | 114.76 | 33.45 | 81.30 | 95.83 | 38.25 | 0.00 | 0.00 | 720.00 |
July | 123.72 | 45.68 | 78.03 | 116.70 | 30.21 | 0.00 | 0.00 | 744.00 |
August | 147.05 | 74.14 | 72.92 | 148.59 | 34.41 | 0.00 | 0.00 | 744.00 |
September | 163.17 | 100.00 | 63.17 | 172.21 | 49.24 | 0.00 | 0.00 | 720.00 |
October | 170.57 | 117.96 | 52.61 | 178.76 | 70.69 | 0.00 | 0.00 | 744.00 |
November | 155.43 | 112.58 | 42.85 | 157.61 | 89.40 | 0.00 | 0.00 | 720.00 |
December | 135.07 | 97.52 | 37.55 | 128.93 | 122.01 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 144.76 | 83.39 | 61.37 | 137.78 | 74.64 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.76 | 33.45 | 37.55 | 89.06 | 30.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.96 | 130.15 | 81.30 | 178.76 | 142.37 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 142.04 | 101.44 | 40.61 | 131.29 | 142.37 | 0.00 | 0.00 | 744.00 |
February | 180.96 | 130.15 | 50.80 | 178.29 | 105.81 | 0.00 | 0.00 | 672.00 |
March | 161.82 | 90.90 | 70.92 | 149.25 | 92.98 | 0.00 | 0.00 | 744.00 |
April | 130.03 | 62.20 | 67.83 | 110.24 | 67.56 | 0.00 | 0.00 | 720.00 |
May | 115.50 | 38.35 | 77.15 | 89.06 | 54.06 | 0.00 | 0.00 | 744.00 |
June | 114.76 | 33.45 | 81.30 | 95.83 | 38.25 | 0.00 | 0.00 | 720.00 |
July | 123.72 | 45.68 | 78.03 | 116.70 | 30.21 | 0.00 | 0.00 | 744.00 |
August | 147.05 | 74.14 | 72.92 | 148.59 | 34.41 | 0.00 | 0.00 | 744.00 |
September | 163.17 | 100.00 | 63.17 | 172.21 | 49.24 | 0.00 | 0.00 | 720.00 |
October | 170.57 | 117.96 | 52.61 | 178.76 | 70.69 | 0.00 | 0.00 | 744.00 |
November | 155.43 | 112.58 | 42.85 | 157.61 | 89.40 | 0.00 | 0.00 | 720.00 |
December | 135.07 | 97.52 | 37.55 | 128.93 | 122.01 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 144.76 | 83.39 | 61.37 | 137.78 | 74.64 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.76 | 33.45 | 37.55 | 89.06 | 30.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.96 | 130.15 | 81.30 | 178.76 | 142.37 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 107.93 | 123.30 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 146.47 | 92.75 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 122.49 | 82.18 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 89.67 | 61.29 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.40 | 48.45 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.86 | 33.17 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.89 | 25.58 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.26 | 29.26 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.27 | 42.82 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 146.96 | 62.49 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 129.24 | 78.98 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 105.96 | 105.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.30 | 65.42 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.40 | 25.58 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 146.96 | 123.30 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 107.93 | 123.30 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 146.47 | 92.75 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 122.49 | 82.18 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 89.67 | 61.29 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.40 | 48.45 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.86 | 33.17 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.89 | 25.58 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.26 | 29.26 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.27 | 42.82 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 146.96 | 62.49 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 129.24 | 78.98 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 105.96 | 105.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.30 | 65.42 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.40 | 25.58 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 146.96 | 123.30 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 142.04 | 101.44 | 40.61 | 130.17 | 147.08 | 0.00 | 0.00 | 744.00 |
February | 180.96 | 130.15 | 50.80 | 176.55 | 110.68 | 0.00 | 0.00 | 672.00 |
March | 161.82 | 90.90 | 70.92 | 147.66 | 98.09 | 0.00 | 0.00 | 744.00 |
April | 130.03 | 62.20 | 67.83 | 108.07 | 73.20 | 0.00 | 0.00 | 720.00 |
May | 115.50 | 38.35 | 77.15 | 87.27 | 57.87 | 0.00 | 0.00 | 744.00 |
June | 114.76 | 33.45 | 81.30 | 94.92 | 39.68 | 0.00 | 0.00 | 720.00 |
July | 123.72 | 45.68 | 78.03 | 116.52 | 30.66 | 0.00 | 0.00 | 744.00 |
August | 147.05 | 74.14 | 72.92 | 148.27 | 35.04 | 0.00 | 0.00 | 744.00 |
September | 163.17 | 100.00 | 63.17 | 171.24 | 51.22 | 0.00 | 0.00 | 720.00 |
October | 170.57 | 117.96 | 52.61 | 176.98 | 74.70 | 0.00 | 0.00 | 744.00 |
November | 155.43 | 112.58 | 42.85 | 155.73 | 94.31 | 0.00 | 0.00 | 720.00 |
December | 135.07 | 97.52 | 37.55 | 127.78 | 126.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 144.76 | 83.39 | 61.37 | 136.48 | 78.13 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.76 | 33.45 | 37.55 | 87.27 | 30.66 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.96 | 130.15 | 81.30 | 176.98 | 147.08 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.15 | 120.98 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 146.81 | 90.80 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 122.76 | 80.32 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 89.93 | 59.93 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.49 | 47.95 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.62 | 34.15 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.40 | 27.16 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.92 | 30.75 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.10 | 43.66 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 147.15 | 61.97 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 129.62 | 77.30 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.24 | 103.82 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.36 | 64.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.49 | 27.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 147.15 | 120.98 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.15 | 120.98 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 146.81 | 90.80 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 122.76 | 80.32 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 89.93 | 59.93 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.49 | 47.95 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.62 | 34.15 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.40 | 27.16 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.92 | 30.75 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.10 | 43.66 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 147.15 | 61.97 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 129.62 | 77.30 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.24 | 103.82 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.36 | 64.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.49 | 27.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 147.15 | 120.98 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 129.73 | 143.52 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 176.00 | 107.78 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 147.18 | 95.35 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 107.79 | 71.19 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 86.89 | 56.95 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 94.12 | 40.60 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.30 | 32.34 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.06 | 36.60 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 170.11 | 51.93 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 176.25 | 73.67 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 155.34 | 91.81 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 127.41 | 123.24 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 135.82 | 76.97 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 86.89 | 32.34 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 176.25 | 143.52 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.28 | 120.00 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.04 | 89.88 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 122.95 | 79.46 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 90.22 | 59.02 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.71 | 47.31 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.67 | 34.02 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.38 | 27.21 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.91 | 30.76 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.17 | 43.44 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 147.36 | 61.31 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 129.91 | 76.30 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.39 | 102.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.51 | 64.21 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.71 | 27.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 147.36 | 120.00 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.28 | 120.00 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.04 | 89.88 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 122.95 | 79.46 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 90.22 | 59.02 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 72.71 | 47.31 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.67 | 34.02 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.38 | 27.21 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 122.91 | 30.76 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.17 | 43.44 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 147.36 | 61.31 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 129.91 | 76.30 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.39 | 102.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.51 | 64.21 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 72.71 | 27.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 147.36 | 120.00 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 129.89 | 142.35 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 176.27 | 106.68 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 147.41 | 94.32 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 108.14 | 70.11 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 87.16 | 56.20 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 94.19 | 40.45 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.28 | 32.40 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.06 | 36.61 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 170.20 | 51.66 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 176.50 | 72.88 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 155.68 | 90.62 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 127.59 | 122.17 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 136.00 | 76.27 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 87.16 | 32.40 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 176.50 | 142.35 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.44 | 119.19 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.32 | 89.05 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.21 | 78.67 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 90.67 | 57.96 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 73.16 | 46.45 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.91 | 33.58 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.52 | 26.90 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.06 | 30.40 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.42 | 42.86 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 147.76 | 60.36 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 130.31 | 75.25 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.57 | 102.17 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.79 | 63.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 73.16 | 26.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 147.76 | 119.19 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.44 | 119.19 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.32 | 89.05 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.21 | 78.67 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 90.67 | 57.96 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 73.16 | 46.45 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 78.91 | 33.58 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.52 | 26.90 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.06 | 30.40 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.42 | 42.86 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 147.76 | 60.36 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 130.31 | 75.25 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.57 | 102.17 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 113.79 | 63.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 73.16 | 26.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 147.76 | 119.19 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 130.09 | 141.38 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 176.62 | 105.69 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 147.72 | 93.39 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 108.67 | 68.85 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 87.70 | 55.17 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 94.48 | 39.92 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.45 | 32.04 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.24 | 36.19 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 170.49 | 50.97 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 176.98 | 71.75 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 156.16 | 89.37 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 127.82 | 121.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 136.33 | 75.40 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 87.70 | 32.04 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 176.98 | 141.38 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 109.12 | 116.40 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.33 | 86.58 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.96 | 76.46 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.75 | 55.52 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.25 | 44.27 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.41 | 32.22 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.56 | 25.90 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.20 | 29.27 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.00 | 41.31 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.93 | 58.01 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.32 | 72.79 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.27 | 99.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.52 | 61.45 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.25 | 25.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.93 | 116.40 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 109.12 | 116.40 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.33 | 86.58 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.96 | 76.46 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.75 | 55.52 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.25 | 44.27 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.41 | 32.22 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.56 | 25.90 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.20 | 29.27 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.00 | 41.31 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.93 | 58.01 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.32 | 72.79 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.27 | 99.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.52 | 61.45 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.25 | 25.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.93 | 116.40 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 109.12 | 116.40 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.33 | 86.58 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.96 | 76.46 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.75 | 55.52 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.25 | 44.27 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.41 | 32.22 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.56 | 25.90 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.20 | 29.27 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.00 | 41.31 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.93 | 58.01 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.32 | 72.79 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.27 | 99.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.52 | 61.45 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.25 | 25.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.93 | 116.40 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 109.12 | 116.40 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.33 | 86.58 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.96 | 76.46 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.75 | 55.52 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.25 | 44.27 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.41 | 32.22 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.56 | 25.90 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.20 | 29.27 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.00 | 41.31 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.93 | 58.01 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.32 | 72.79 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.27 | 99.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.52 | 61.45 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.25 | 25.90 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.93 | 116.40 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 130.90 | 138.09 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 177.81 | 102.77 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 148.62 | 90.77 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 109.96 | 65.96 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 89.01 | 52.60 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 95.08 | 38.31 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.50 | 30.85 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.42 | 34.85 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 171.18 | 49.13 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 178.37 | 68.97 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 157.37 | 86.46 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 128.66 | 118.39 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 137.20 | 73.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 89.01 | 30.85 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 178.37 | 138.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 130.90 | 138.09 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 177.81 | 102.77 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 148.62 | 90.77 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 109.96 | 65.96 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 89.01 | 52.60 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 95.08 | 38.31 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.50 | 30.85 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.42 | 34.85 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 171.18 | 49.13 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 178.37 | 68.97 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 157.37 | 86.46 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 128.66 | 118.39 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 137.20 | 73.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 89.01 | 30.85 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 178.37 | 138.09 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.77 | 117.01 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.94 | 86.93 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.68 | 76.66 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.53 | 55.64 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.06 | 44.38 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.39 | 32.21 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.74 | 25.70 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.26 | 29.11 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.79 | 41.37 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.49 | 58.29 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.01 | 73.02 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.95 | 100.14 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.31 | 61.62 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.06 | 25.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.49 | 117.01 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.77 | 117.01 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 147.94 | 86.93 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.68 | 76.66 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.53 | 55.64 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.06 | 44.38 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.39 | 32.21 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.74 | 25.70 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.26 | 29.11 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.79 | 41.37 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.49 | 58.29 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.01 | 73.02 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 106.95 | 100.14 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.31 | 61.62 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.06 | 25.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.49 | 117.01 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 130.50 | 138.79 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 177.37 | 103.17 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 148.31 | 90.99 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 109.72 | 66.09 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 88.79 | 52.71 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 95.06 | 38.29 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.72 | 30.60 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.49 | 34.65 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 170.95 | 49.20 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 177.86 | 69.29 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 157.01 | 86.72 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 128.28 | 118.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 136.97 | 73.18 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 88.79 | 30.60 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 177.86 | 138.79 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.81 | 116.81 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.02 | 86.69 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.76 | 76.39 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.66 | 55.32 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.21 | 44.11 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.51 | 32.03 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.82 | 25.57 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.34 | 28.98 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.87 | 41.22 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.58 | 58.08 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.10 | 72.79 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.01 | 99.91 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.40 | 61.41 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.21 | 25.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.58 | 116.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.81 | 116.81 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.02 | 86.69 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 123.76 | 76.39 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 91.66 | 55.32 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.21 | 44.11 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.51 | 32.03 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 96.82 | 25.57 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.34 | 28.98 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 142.87 | 41.22 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.58 | 58.08 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.10 | 72.79 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.01 | 99.91 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.40 | 61.41 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.21 | 25.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.58 | 116.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 130.55 | 138.55 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 177.47 | 102.88 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 148.40 | 90.67 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 109.88 | 65.71 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 88.97 | 52.39 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 95.21 | 38.08 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 115.83 | 30.46 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.58 | 34.50 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 171.04 | 49.02 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 177.97 | 69.05 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 157.12 | 86.44 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 128.35 | 118.58 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 137.08 | 72.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 88.97 | 30.46 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 177.97 | 138.55 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.97 | 115.93 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.31 | 85.70 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 124.01 | 75.40 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 92.06 | 54.19 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.69 | 43.15 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.92 | 31.39 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.01 | 25.24 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.51 | 28.62 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.10 | 40.67 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.92 | 57.28 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.36 | 71.97 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.20 | 98.99 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.68 | 60.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.69 | 25.24 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.92 | 115.93 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 108.97 | 115.93 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 148.31 | 85.70 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 124.01 | 75.40 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 92.06 | 54.19 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 74.69 | 43.15 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 79.92 | 31.39 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.01 | 25.24 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.51 | 28.62 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.10 | 40.67 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 148.92 | 57.28 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 131.36 | 71.97 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.20 | 98.99 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 114.68 | 60.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 74.69 | 25.24 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 148.92 | 115.93 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 130.74 | 137.49 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 177.82 | 101.70 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 148.71 | 89.48 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 110.36 | 64.37 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 89.55 | 51.26 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 95.70 | 37.32 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 116.05 | 30.06 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 147.79 | 34.07 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 171.32 | 48.37 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 178.38 | 68.09 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 157.44 | 85.47 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 128.59 | 117.48 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 137.42 | 72.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 89.55 | 30.06 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 178.38 | 137.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 109.62 | 112.13 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 149.30 | 81.68 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 124.93 | 71.35 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 93.20 | 50.23 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 75.95 | 39.96 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 81.07 | 29.18 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.48 | 23.99 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.93 | 27.29 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.63 | 38.84 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 149.67 | 54.84 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 132.14 | 69.02 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.92 | 95.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 115.50 | 57.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 75.95 | 23.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 149.67 | 112.13 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 117.98 | 84.25 | 33.73 | 109.62 | 112.13 | 0.00 | 0.00 | 744.00 |
February | 150.30 | 108.10 | 42.20 | 149.30 | 81.68 | 0.00 | 0.00 | 672.00 |
March | 134.40 | 75.50 | 58.90 | 124.93 | 71.35 | 0.00 | 0.00 | 744.00 |
April | 108.00 | 51.66 | 56.34 | 93.20 | 50.23 | 0.00 | 0.00 | 720.00 |
May | 95.93 | 31.85 | 64.08 | 75.95 | 39.96 | 0.00 | 0.00 | 744.00 |
June | 95.32 | 27.79 | 67.53 | 81.07 | 29.18 | 0.00 | 0.00 | 720.00 |
July | 102.76 | 37.95 | 64.81 | 97.48 | 23.99 | 0.00 | 0.00 | 744.00 |
August | 122.14 | 61.58 | 60.56 | 123.93 | 27.29 | 0.00 | 0.00 | 744.00 |
September | 135.53 | 83.06 | 52.47 | 143.63 | 38.84 | 0.00 | 0.00 | 720.00 |
October | 141.68 | 97.98 | 43.70 | 149.67 | 54.84 | 0.00 | 0.00 | 744.00 |
November | 129.10 | 93.51 | 35.59 | 132.14 | 69.02 | 0.00 | 0.00 | 720.00 |
December | 112.19 | 81.00 | 31.19 | 107.92 | 95.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 120.24 | 69.26 | 50.97 | 115.50 | 57.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 95.32 | 27.79 | 31.19 | 75.95 | 23.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 150.30 | 108.10 | 67.53 | 149.67 | 112.13 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 141.27 | 100.88 | 40.39 | 131.52 | 132.98 | 0.00 | 0.00 | 744.00 |
February | 179.97 | 129.44 | 50.53 | 179.02 | 96.93 | 0.00 | 0.00 | 672.00 |
March | 160.93 | 90.40 | 70.53 | 149.82 | 84.67 | 0.00 | 0.00 | 744.00 |
April | 129.32 | 61.86 | 67.46 | 111.74 | 59.66 | 0.00 | 0.00 | 720.00 |
May | 114.87 | 38.14 | 76.73 | 91.07 | 47.47 | 0.00 | 0.00 | 744.00 |
June | 114.13 | 33.27 | 80.86 | 97.08 | 34.70 | 0.00 | 0.00 | 720.00 |
July | 123.04 | 45.43 | 77.61 | 116.62 | 28.58 | 0.00 | 0.00 | 744.00 |
August | 146.25 | 73.73 | 72.52 | 148.30 | 32.50 | 0.00 | 0.00 | 744.00 |
September | 162.28 | 99.46 | 62.82 | 171.96 | 46.20 | 0.00 | 0.00 | 720.00 |
October | 169.64 | 117.32 | 52.32 | 179.28 | 65.20 | 0.00 | 0.00 | 744.00 |
November | 154.58 | 111.96 | 42.62 | 158.38 | 81.97 | 0.00 | 0.00 | 720.00 |
December | 134.33 | 96.99 | 37.35 | 129.46 | 113.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.97 | 82.93 | 61.04 | 138.40 | 68.57 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 114.13 | 33.27 | 37.35 | 91.07 | 28.58 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 179.97 | 129.44 | 80.86 | 179.28 | 132.98 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291567E+09 | 0.319648E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.357847E+09 | 0.214434E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331630E+09 | 0.208593E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237109E+09 | 0.146559E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.197931E+09 | 0.121163E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.206343E+09 | 82878151.93 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259904E+09 | 67513689.23 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330835E+09 | 76936073.38 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370869E+09 | 0.106647E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397608E+09 | 0.158320E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339073E+09 | 0.193970E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286380E+09 | 0.273742E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360710E+10 | 0.197040E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.197931E+09 | 67513689.23 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397608E+09 | 0.319648E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291567E+09 | 0.319648E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.357847E+09 | 0.214434E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331630E+09 | 0.208593E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237109E+09 | 0.146559E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.197931E+09 | 0.121163E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.206343E+09 | 82878151.93 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259904E+09 | 67513689.23 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330835E+09 | 76936073.38 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370869E+09 | 0.106647E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397608E+09 | 0.158320E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339073E+09 | 0.193970E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286380E+09 | 0.273742E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360710E+10 | 0.197040E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.197931E+09 | 67513689.23 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397608E+09 | 0.319648E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291567E+09 | 0.319648E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.357847E+09 | 0.214434E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331630E+09 | 0.208593E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237109E+09 | 0.146559E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.197931E+09 | 0.121163E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.206343E+09 | 82878151.93 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259904E+09 | 67513689.23 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330835E+09 | 76936073.38 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370869E+09 | 0.106647E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397608E+09 | 0.158320E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339073E+09 | 0.193970E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286380E+09 | 0.273742E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360710E+10 | 0.197040E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.197931E+09 | 67513689.23 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397608E+09 | 0.319648E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291567E+09 | 0.319648E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.357847E+09 | 0.214434E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331630E+09 | 0.208593E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237109E+09 | 0.146559E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.197931E+09 | 0.121163E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.206343E+09 | 82878151.93 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259904E+09 | 67513689.23 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330835E+09 | 76936073.38 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370869E+09 | 0.106647E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397608E+09 | 0.158320E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339073E+09 | 0.193970E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286380E+09 | 0.273742E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360710E+10 | 0.197040E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.197931E+09 | 67513689.23 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397608E+09 | 0.319648E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.380453E+09 | 0.271690E+09 | 0.108762E+09 | 0.351645E+09 | 0.381329E+09 |
February | 0.437770E+09 | 0.314863E+09 | 0.122907E+09 | 0.431310E+09 | 0.255968E+09 |
March | 0.433407E+09 | 0.243461E+09 | 0.189946E+09 | 0.399759E+09 | 0.249034E+09 |
April | 0.337031E+09 | 0.161216E+09 | 0.175815E+09 | 0.285731E+09 | 0.175127E+09 |
May | 0.309355E+09 | 0.102713E+09 | 0.206642E+09 | 0.238550E+09 | 0.144796E+09 |
June | 0.297452E+09 | 86712993.89 | 0.210739E+09 | 0.248387E+09 | 99149679.12 |
July | 0.331364E+09 | 0.122361E+09 | 0.209003E+09 | 0.312563E+09 | 80919723.88 |
August | 0.393866E+09 | 0.198570E+09 | 0.195296E+09 | 0.397988E+09 | 92172951.78 |
September | 0.422938E+09 | 0.259211E+09 | 0.163727E+09 | 0.446373E+09 | 0.127627E+09 |
October | 0.456854E+09 | 0.315950E+09 | 0.140904E+09 | 0.478796E+09 | 0.189348E+09 |
November | 0.402876E+09 | 0.291803E+09 | 0.111073E+09 | 0.408524E+09 | 0.231726E+09 |
December | 0.361772E+09 | 0.261197E+09 | 0.100575E+09 | 0.345323E+09 | 0.326788E+09 |
Annual Sum or Average | 0.456514E+10 | 0.262975E+10 | 0.193539E+10 | 0.434495E+10 | 0.235398E+10 |
Minimum of Months | 0.297452E+09 | 86712993.89 | 0.100575E+09 | 0.238550E+09 | 80919723.88 |
Maximum of Months | 0.456854E+09 | 0.315950E+09 | 0.210739E+09 | 0.478796E+09 | 0.381329E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.380453E+09 | 0.271690E+09 | 0.108762E+09 | 0.351645E+09 | 0.381329E+09 |
February | 0.437770E+09 | 0.314863E+09 | 0.122907E+09 | 0.431310E+09 | 0.255968E+09 |
March | 0.433407E+09 | 0.243461E+09 | 0.189946E+09 | 0.399759E+09 | 0.249034E+09 |
April | 0.337031E+09 | 0.161216E+09 | 0.175815E+09 | 0.285731E+09 | 0.175127E+09 |
May | 0.309355E+09 | 0.102713E+09 | 0.206642E+09 | 0.238550E+09 | 0.144796E+09 |
June | 0.297452E+09 | 86712993.89 | 0.210739E+09 | 0.248387E+09 | 99149679.12 |
July | 0.331364E+09 | 0.122361E+09 | 0.209003E+09 | 0.312563E+09 | 80919723.88 |
August | 0.393866E+09 | 0.198570E+09 | 0.195296E+09 | 0.397988E+09 | 92172951.78 |
September | 0.422938E+09 | 0.259211E+09 | 0.163727E+09 | 0.446373E+09 | 0.127627E+09 |
October | 0.456854E+09 | 0.315950E+09 | 0.140904E+09 | 0.478796E+09 | 0.189348E+09 |
November | 0.402876E+09 | 0.291803E+09 | 0.111073E+09 | 0.408524E+09 | 0.231726E+09 |
December | 0.361772E+09 | 0.261197E+09 | 0.100575E+09 | 0.345323E+09 | 0.326788E+09 |
Annual Sum or Average | 0.456514E+10 | 0.262975E+10 | 0.193539E+10 | 0.434495E+10 | 0.235398E+10 |
Minimum of Months | 0.297452E+09 | 86712993.89 | 0.100575E+09 | 0.238550E+09 | 80919723.88 |
Maximum of Months | 0.456854E+09 | 0.315950E+09 | 0.210739E+09 | 0.478796E+09 | 0.381329E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.289081E+09 | 0.330255E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.354329E+09 | 0.224377E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.328073E+09 | 0.220119E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.232425E+09 | 0.158868E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.193928E+09 | 0.129763E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.204403E+09 | 85985699.53 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259523E+09 | 68511962.84 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330136E+09 | 78360374.36 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368760E+09 | 0.110984E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.393605E+09 | 0.167375E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.334989E+09 | 0.204720E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.283816E+09 | 0.283705E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.357307E+10 | 0.206302E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.193928E+09 | 68511962.84 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.393605E+09 | 0.330255E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.289081E+09 | 0.330255E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.354329E+09 | 0.224377E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.328073E+09 | 0.220119E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.232425E+09 | 0.158868E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.193928E+09 | 0.129763E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.204403E+09 | 85985699.53 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259523E+09 | 68511962.84 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330136E+09 | 78360374.36 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368760E+09 | 0.110984E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.393605E+09 | 0.167375E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.334989E+09 | 0.204720E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.283816E+09 | 0.283705E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.357307E+10 | 0.206302E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.193928E+09 | 68511962.84 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.393605E+09 | 0.330255E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.380453E+09 | 0.271690E+09 | 0.108762E+09 | 0.348658E+09 | 0.393929E+09 |
February | 0.437770E+09 | 0.314863E+09 | 0.122907E+09 | 0.427103E+09 | 0.267765E+09 |
March | 0.433407E+09 | 0.243461E+09 | 0.189946E+09 | 0.395488E+09 | 0.262714E+09 |
April | 0.337031E+09 | 0.161216E+09 | 0.175815E+09 | 0.280107E+09 | 0.189738E+09 |
May | 0.309355E+09 | 0.102713E+09 | 0.206642E+09 | 0.233734E+09 | 0.154991E+09 |
June | 0.297452E+09 | 86712993.89 | 0.210739E+09 | 0.246045E+09 | 0.102839E+09 |
July | 0.331364E+09 | 0.122361E+09 | 0.209003E+09 | 0.312083E+09 | 82108799.05 |
August | 0.393866E+09 | 0.198570E+09 | 0.195296E+09 | 0.397136E+09 | 93861613.44 |
September | 0.422938E+09 | 0.259211E+09 | 0.163727E+09 | 0.443854E+09 | 0.132761E+09 |
October | 0.456854E+09 | 0.315950E+09 | 0.140904E+09 | 0.474032E+09 | 0.200072E+09 |
November | 0.402876E+09 | 0.291803E+09 | 0.111073E+09 | 0.403657E+09 | 0.244461E+09 |
December | 0.361772E+09 | 0.261197E+09 | 0.100575E+09 | 0.342250E+09 | 0.338606E+09 |
Annual Sum or Average | 0.456514E+10 | 0.262975E+10 | 0.193539E+10 | 0.430415E+10 | 0.246385E+10 |
Minimum of Months | 0.297452E+09 | 86712993.89 | 0.100575E+09 | 0.233734E+09 | 82108799.05 |
Maximum of Months | 0.456854E+09 | 0.315950E+09 | 0.210739E+09 | 0.474032E+09 | 0.393929E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.289674E+09 | 0.324038E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.355168E+09 | 0.219667E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.328801E+09 | 0.215139E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.233104E+09 | 0.155336E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.194152E+09 | 0.128427E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.203779E+09 | 88525467.75 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258187E+09 | 72757166.44 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329225E+09 | 82350677.80 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368327E+09 | 0.113177E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.394135E+09 | 0.165989E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.335980E+09 | 0.200361E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.284547E+09 | 0.278072E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.357508E+10 | 0.204384E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.194152E+09 | 72757166.44 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.394135E+09 | 0.324038E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.289674E+09 | 0.324038E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.355168E+09 | 0.219667E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.328801E+09 | 0.215139E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.233104E+09 | 0.155336E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.194152E+09 | 0.128427E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.203779E+09 | 88525467.75 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258187E+09 | 72757166.44 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329225E+09 | 82350677.80 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368327E+09 | 0.113177E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.394135E+09 | 0.165989E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.335980E+09 | 0.200361E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.284547E+09 | 0.278072E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.357508E+10 | 0.204384E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.194152E+09 | 72757166.44 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.394135E+09 | 0.324038E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.347473E+09 | 0.384408E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.425780E+09 | 0.260731E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.394204E+09 | 0.255393E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.279391E+09 | 0.184526E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.232734E+09 | 0.152541E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.243965E+09 | 0.105237E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.308809E+09 | 86631477.31 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.393891E+09 | 98021232.28 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.440922E+09 | 0.134591E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.472075E+09 | 0.197315E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.402637E+09 | 0.237965E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.341263E+09 | 0.330087E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.428314E+10 | 0.242745E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.232734E+09 | 86631477.31 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.472075E+09 | 0.384408E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.290027E+09 | 0.321412E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.355709E+09 | 0.217444E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.329322E+09 | 0.212821E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.233849E+09 | 0.152976E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.194756E+09 | 0.126723E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.203919E+09 | 88191063.56 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258147E+09 | 72882474.59 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329213E+09 | 82381142.29 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368517E+09 | 0.112595E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.394683E+09 | 0.164203E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.336717E+09 | 0.197774E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.284947E+09 | 0.275676E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.357980E+10 | 0.202508E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.194756E+09 | 72882474.59 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.394683E+09 | 0.321412E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.290027E+09 | 0.321412E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.355709E+09 | 0.217444E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.329322E+09 | 0.212821E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.233849E+09 | 0.152976E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.194756E+09 | 0.126723E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.203919E+09 | 88191063.56 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258147E+09 | 72882474.59 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329213E+09 | 82381142.29 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.368517E+09 | 0.112595E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.394683E+09 | 0.164203E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.336717E+09 | 0.197774E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.284947E+09 | 0.275676E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.357980E+10 | 0.202508E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.194756E+09 | 72882474.59 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.394683E+09 | 0.321412E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.347903E+09 | 0.381277E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.426432E+09 | 0.258084E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.394835E+09 | 0.252633E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.280287E+09 | 0.181721E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.233460E+09 | 0.150515E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.244133E+09 | 0.104839E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.308761E+09 | 86780896.74 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.393876E+09 | 98057436.89 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.441151E+09 | 0.133900E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.472734E+09 | 0.195192E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.403522E+09 | 0.234888E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.341748E+09 | 0.327231E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.428884E+10 | 0.240512E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.233460E+09 | 86780896.74 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.472734E+09 | 0.381277E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.290457E+09 | 0.319234E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.356402E+09 | 0.215425E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.329997E+09 | 0.210715E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.235004E+09 | 0.150240E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.195940E+09 | 0.124400E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.204543E+09 | 87027916.96 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258529E+09 | 72062181.58 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329613E+09 | 81426951.15 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.369142E+09 | 0.111097E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.395766E+09 | 0.161664E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.337757E+09 | 0.195040E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.285436E+09 | 0.273655E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.358859E+10 | 0.200199E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.195940E+09 | 72062181.58 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.395766E+09 | 0.319234E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.290457E+09 | 0.319234E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.356402E+09 | 0.215425E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.329997E+09 | 0.210715E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.235004E+09 | 0.150240E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.195940E+09 | 0.124400E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.204543E+09 | 87027916.96 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258529E+09 | 72062181.58 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329613E+09 | 81426951.15 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.369142E+09 | 0.111097E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.395766E+09 | 0.161664E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.337757E+09 | 0.195040E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.285436E+09 | 0.273655E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.358859E+10 | 0.200199E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.195940E+09 | 72062181.58 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.395766E+09 | 0.319234E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.348428E+09 | 0.378678E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.427268E+09 | 0.255680E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.395651E+09 | 0.250125E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.281674E+09 | 0.178469E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.234885E+09 | 0.147759E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.244886E+09 | 0.103462E+09 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.309222E+09 | 85809790.37 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.394360E+09 | 96928092.85 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.441904E+09 | 0.132124E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.474032E+09 | 0.192179E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.404768E+09 | 0.231639E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.342342E+09 | 0.324821E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.429942E+10 | 0.237767E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.234885E+09 | 85809790.37 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.474032E+09 | 0.378678E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.292280E+09 | 0.311761E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358834E+09 | 0.209458E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.332010E+09 | 0.204784E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237809E+09 | 0.143914E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198863E+09 | 0.118580E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205833E+09 | 83503126.51 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258613E+09 | 69379539.76 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329991E+09 | 78408457.27 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370652E+09 | 0.107067E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.398896E+09 | 0.155365E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.340388E+09 | 0.188672E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.287318E+09 | 0.267126E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.361149E+10 | 0.193802E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198863E+09 | 69379539.76 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.398896E+09 | 0.311761E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.292280E+09 | 0.311761E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358834E+09 | 0.209458E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.332010E+09 | 0.204784E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237809E+09 | 0.143914E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198863E+09 | 0.118580E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205833E+09 | 83503126.51 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258613E+09 | 69379539.76 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329991E+09 | 78408457.27 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370652E+09 | 0.107067E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.398896E+09 | 0.155365E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.340388E+09 | 0.188672E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.287318E+09 | 0.267126E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.361149E+10 | 0.193802E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198863E+09 | 69379539.76 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.398896E+09 | 0.311761E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.292280E+09 | 0.311761E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358834E+09 | 0.209458E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.332010E+09 | 0.204784E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237809E+09 | 0.143914E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198863E+09 | 0.118580E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205833E+09 | 83503126.51 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258613E+09 | 69379539.76 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329991E+09 | 78408457.27 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370652E+09 | 0.107067E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.398896E+09 | 0.155365E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.340388E+09 | 0.188672E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.287318E+09 | 0.267126E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.361149E+10 | 0.193802E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198863E+09 | 69379539.76 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.398896E+09 | 0.311761E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.292280E+09 | 0.311761E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358834E+09 | 0.209458E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.332010E+09 | 0.204784E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237809E+09 | 0.143914E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198863E+09 | 0.118580E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205833E+09 | 83503126.51 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.258613E+09 | 69379539.76 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.329991E+09 | 78408457.27 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370652E+09 | 0.107067E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.398896E+09 | 0.155365E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.340388E+09 | 0.188672E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.287318E+09 | 0.267126E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.361149E+10 | 0.193802E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198863E+09 | 69379539.76 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.398896E+09 | 0.311761E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.350609E+09 | 0.369860E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.430161E+09 | 0.248633E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.398062E+09 | 0.243118E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.285028E+09 | 0.170977E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.238394E+09 | 0.140881E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.246450E+09 | 99292293.16 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.309365E+09 | 82631820.23 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.394844E+09 | 93353126.32 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.443707E+09 | 0.127356E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.477740E+09 | 0.184725E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.407897E+09 | 0.224113E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.344590E+09 | 0.317106E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.432685E+10 | 0.230205E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.238394E+09 | 82631820.23 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.477740E+09 | 0.369860E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.350609E+09 | 0.369860E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.430161E+09 | 0.248633E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.398062E+09 | 0.243118E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.285028E+09 | 0.170977E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.238394E+09 | 0.140881E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.246450E+09 | 99292293.16 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.309365E+09 | 82631820.23 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.394844E+09 | 93353126.32 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.443707E+09 | 0.127356E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.477740E+09 | 0.184725E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.407897E+09 | 0.224113E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.344590E+09 | 0.317106E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.432685E+10 | 0.230205E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.238394E+09 | 82631820.23 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.477740E+09 | 0.369860E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291336E+09 | 0.313405E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.357890E+09 | 0.210304E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331271E+09 | 0.205315E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237249E+09 | 0.144221E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198357E+09 | 0.118863E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205769E+09 | 83484437.02 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259106E+09 | 68828534.03 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330152E+09 | 77968041.11 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370114E+09 | 0.107240E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397715E+09 | 0.156120E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339578E+09 | 0.189275E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286449E+09 | 0.268225E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360498E+10 | 0.194325E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198357E+09 | 68828534.03 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397715E+09 | 0.313405E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291336E+09 | 0.313405E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.357890E+09 | 0.210304E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331271E+09 | 0.205315E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237249E+09 | 0.144221E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198357E+09 | 0.118863E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.205769E+09 | 83484437.02 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259106E+09 | 68828534.03 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330152E+09 | 77968041.11 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370114E+09 | 0.107240E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397715E+09 | 0.156120E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339578E+09 | 0.189275E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286449E+09 | 0.268225E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360498E+10 | 0.194325E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198357E+09 | 68828534.03 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397715E+09 | 0.313405E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.349522E+09 | 0.371731E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.429082E+09 | 0.249584E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.397224E+09 | 0.243695E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.284391E+09 | 0.171303E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.237816E+09 | 0.141181E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.246390E+09 | 99252219.90 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.309956E+09 | 81970687.66 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.395049E+09 | 92817550.96 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.443101E+09 | 0.127535E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.476386E+09 | 0.185582E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.406977E+09 | 0.224779E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.343594E+09 | 0.318348E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.431949E+10 | 0.230778E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.237816E+09 | 81970687.66 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.476386E+09 | 0.371731E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291445E+09 | 0.312874E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358097E+09 | 0.209724E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331482E+09 | 0.204613E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237587E+09 | 0.143400E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198757E+09 | 0.118142E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.206099E+09 | 83019717.31 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259330E+09 | 68497633.67 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330350E+09 | 77625057.29 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370315E+09 | 0.106835E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397965E+09 | 0.155575E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339804E+09 | 0.188670E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286604E+09 | 0.267611E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360783E+10 | 0.193659E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198757E+09 | 68497633.67 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397965E+09 | 0.312874E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291445E+09 | 0.312874E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358097E+09 | 0.209724E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.331482E+09 | 0.204613E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.237587E+09 | 0.143400E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.198757E+09 | 0.118142E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.206099E+09 | 83019717.31 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259330E+09 | 68497633.67 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330350E+09 | 77625057.29 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370315E+09 | 0.106835E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.397965E+09 | 0.155575E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.339804E+09 | 0.188670E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.286604E+09 | 0.267611E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.360783E+10 | 0.193659E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.198757E+09 | 68497633.67 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.397965E+09 | 0.312874E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.349654E+09 | 0.371097E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.429332E+09 | 0.248893E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.397480E+09 | 0.242857E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.284799E+09 | 0.170326E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.238299E+09 | 0.140325E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.246787E+09 | 98701110.47 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.310227E+09 | 81576960.10 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.395288E+09 | 92409993.46 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.443342E+09 | 0.127053E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.476686E+09 | 0.184933E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.407250E+09 | 0.224059E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.343783E+09 | 0.317616E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.432293E+10 | 0.229985E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.238299E+09 | 81576960.10 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.476686E+09 | 0.371097E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291861E+09 | 0.310497E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358795E+09 | 0.207328E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.332155E+09 | 0.201938E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.238630E+09 | 0.140465E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.200041E+09 | 0.115577E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.207164E+09 | 81359379.63 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259825E+09 | 67597800.34 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330809E+09 | 76646150.07 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370918E+09 | 0.105409E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.398866E+09 | 0.153422E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.340490E+09 | 0.186545E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.287129E+09 | 0.265131E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.361668E+10 | 0.191192E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.200041E+09 | 67597800.34 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.398866E+09 | 0.310497E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.291861E+09 | 0.310497E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.358795E+09 | 0.207328E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.332155E+09 | 0.201938E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.238630E+09 | 0.140465E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.200041E+09 | 0.115577E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.207164E+09 | 81359379.63 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.259825E+09 | 67597800.34 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.330809E+09 | 76646150.07 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.370918E+09 | 0.105409E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.398866E+09 | 0.153422E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.340490E+09 | 0.186545E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.287129E+09 | 0.265131E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.361668E+10 | 0.191192E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.200041E+09 | 67597800.34 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.398866E+09 | 0.310497E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.350161E+09 | 0.368264E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.430176E+09 | 0.246043E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.398299E+09 | 0.239675E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.286056E+09 | 0.166836E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.239845E+09 | 0.137284E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.248064E+09 | 96730988.05 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.310822E+09 | 80512152.78 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.395842E+09 | 91251664.57 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.444066E+09 | 0.125363E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.477764E+09 | 0.182380E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.408077E+09 | 0.221535E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.344420E+09 | 0.314664E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.433359E+10 | 0.227054E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.239845E+09 | 80512152.78 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.477764E+09 | 0.368264E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.293596E+09 | 0.300342E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.361193E+09 | 0.197597E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.334613E+09 | 0.191095E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.241584E+09 | 0.130194E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.203412E+09 | 0.107016E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.210138E+09 | 75630298.09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.261101E+09 | 64249839.32 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.331932E+09 | 73089137.04 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.372285E+09 | 0.100672E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.400886E+09 | 0.146876E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.342512E+09 | 0.178895E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.289048E+09 | 0.255112E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.364230E+10 | 0.182077E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.203412E+09 | 64249839.32 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.400886E+09 | 0.300342E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.316004E+09 | 0.225666E+09 | 90338001.12 | 0.293596E+09 | 0.300342E+09 |
February | 0.363612E+09 | 0.261526E+09 | 0.102086E+09 | 0.361193E+09 | 0.197597E+09 |
March | 0.359988E+09 | 0.202219E+09 | 0.157769E+09 | 0.334613E+09 | 0.191095E+09 |
April | 0.279938E+09 | 0.133906E+09 | 0.146032E+09 | 0.241584E+09 | 0.130194E+09 |
May | 0.256951E+09 | 85313868.24 | 0.171637E+09 | 0.203412E+09 | 0.107016E+09 |
June | 0.247064E+09 | 72023907.49 | 0.175040E+09 | 0.210138E+09 | 75630298.09 |
July | 0.275231E+09 | 0.101633E+09 | 0.173598E+09 | 0.261101E+09 | 64249839.32 |
August | 0.327145E+09 | 0.164932E+09 | 0.162213E+09 | 0.331932E+09 | 73089137.04 |
September | 0.351293E+09 | 0.215301E+09 | 0.135992E+09 | 0.372285E+09 | 0.100672E+09 |
October | 0.379464E+09 | 0.262428E+09 | 0.117035E+09 | 0.400886E+09 | 0.146876E+09 |
November | 0.334629E+09 | 0.242372E+09 | 92257076.27 | 0.342512E+09 | 0.178895E+09 |
December | 0.300488E+09 | 0.216951E+09 | 83537300.00 | 0.289048E+09 | 0.255112E+09 |
Annual Sum or Average | 0.379181E+10 | 0.218427E+10 | 0.160754E+10 | 0.364230E+10 | 0.182077E+10 |
Minimum of Months | 0.247064E+09 | 72023907.49 | 83537300.00 | 0.203412E+09 | 64249839.32 |
Maximum of Months | 0.379464E+09 | 0.262428E+09 | 0.175040E+09 | 0.400886E+09 | 0.300342E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.378374E+09 | 0.270206E+09 | 0.108168E+09 | 0.352274E+09 | 0.356161E+09 |
February | 0.435378E+09 | 0.313143E+09 | 0.122235E+09 | 0.433081E+09 | 0.234484E+09 |
March | 0.431038E+09 | 0.242130E+09 | 0.188908E+09 | 0.401290E+09 | 0.226788E+09 |
April | 0.335189E+09 | 0.160335E+09 | 0.174854E+09 | 0.289631E+09 | 0.154641E+09 |
May | 0.307665E+09 | 0.102152E+09 | 0.205513E+09 | 0.243913E+09 | 0.127143E+09 |
June | 0.295827E+09 | 86239152.39 | 0.209588E+09 | 0.251634E+09 | 89947747.25 |
July | 0.329553E+09 | 0.121693E+09 | 0.207861E+09 | 0.312357E+09 | 76548796.76 |
August | 0.391714E+09 | 0.197485E+09 | 0.194229E+09 | 0.397194E+09 | 87041543.99 |
September | 0.420627E+09 | 0.257795E+09 | 0.162832E+09 | 0.445711E+09 | 0.119760E+09 |
October | 0.454358E+09 | 0.314223E+09 | 0.140134E+09 | 0.480191E+09 | 0.174629E+09 |
November | 0.400674E+09 | 0.290209E+09 | 0.110466E+09 | 0.410524E+09 | 0.212467E+09 |
December | 0.359795E+09 | 0.259770E+09 | 0.100025E+09 | 0.346754E+09 | 0.302759E+09 |
Annual Sum or Average | 0.454019E+10 | 0.261538E+10 | 0.192481E+10 | 0.436456E+10 | 0.216237E+10 |
Minimum of Months | 0.295827E+09 | 86239152.39 | 0.100025E+09 | 0.243913E+09 | 76548796.76 |
Maximum of Months | 0.454358E+09 | 0.314223E+09 | 0.209588E+09 | 0.480191E+09 | 0.356161E+09 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 698.01 | 762.11 | 756.02 | 539.89 | 216.13 | 0.00 | 0.00 |
February | 948.25 | 566.17 | 963.12 | 692.72 | 270.40 | 0.00 | 0.00 |
March | 793.77 | 497.48 | 861.25 | 483.79 | 377.45 | 0.00 | 0.00 |
April | 586.38 | 361.30 | 692.06 | 331.04 | 361.02 | 0.00 | 0.00 |
May | 473.72 | 289.07 | 614.74 | 204.11 | 410.63 | 0.00 | 0.00 |
June | 510.09 | 204.40 | 610.79 | 178.06 | 432.73 | 0.00 | 0.00 |
July | 621.54 | 161.25 | 658.47 | 243.15 | 415.32 | 0.00 | 0.00 |
August | 791.26 | 183.73 | 782.67 | 394.59 | 388.08 | 0.00 | 0.00 |
September | 916.75 | 263.06 | 868.46 | 532.26 | 336.20 | 0.00 | 0.00 |
October | 951.32 | 377.83 | 907.84 | 627.84 | 280.00 | 0.00 | 0.00 |
November | 838.48 | 478.14 | 827.26 | 599.19 | 228.08 | 0.00 | 0.00 |
December | 685.55 | 652.83 | 718.90 | 519.04 | 199.86 | 0.00 | 0.00 |
Annual Sum or Average | 733.08 | 399.21 | 770.47 | 443.83 | 326.64 | 0.00 | 0.00 |
Minimum of Months | 473.72 | 161.25 | 610.79 | 178.06 | 199.86 | 0.00 | 0.00 |
Maximum of Months | 951.32 | 762.11 | 963.12 | 692.72 | 432.73 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 346.03 | 393.68 | 378.01 | 269.95 | 108.06 | 0.00 | 0.00 |
February | 469.48 | 296.18 | 481.56 | 346.36 | 135.20 | 0.00 | 0.00 |
March | 392.63 | 262.45 | 430.62 | 241.90 | 188.73 | 0.00 | 0.00 |
April | 287.41 | 195.78 | 346.03 | 165.52 | 180.51 | 0.00 | 0.00 |
May | 232.07 | 154.76 | 307.37 | 102.05 | 205.32 | 0.00 | 0.00 |
June | 252.64 | 106.02 | 305.39 | 89.03 | 216.37 | 0.00 | 0.00 |
July | 310.31 | 81.81 | 329.24 | 121.58 | 207.66 | 0.00 | 0.00 |
August | 394.79 | 93.56 | 391.34 | 197.29 | 194.04 | 0.00 | 0.00 |
September | 455.78 | 136.86 | 434.23 | 266.13 | 168.10 | 0.00 | 0.00 |
October | 470.89 | 199.68 | 453.92 | 313.92 | 140.00 | 0.00 | 0.00 |
November | 414.21 | 252.28 | 413.63 | 299.59 | 114.04 | 0.00 | 0.00 |
December | 339.71 | 338.27 | 359.45 | 259.52 | 99.93 | 0.00 | 0.00 |
Annual Sum or Average | 363.09 | 208.96 | 385.23 | 221.91 | 163.32 | 0.00 | 0.00 |
Minimum of Months | 232.07 | 81.81 | 305.39 | 89.03 | 99.93 | 0.00 | 0.00 |
Maximum of Months | 470.89 | 393.68 | 481.56 | 346.36 | 216.37 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 346.03 | 385.48 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 469.62 | 289.38 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 392.70 | 256.00 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 287.65 | 191.05 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 231.87 | 152.85 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 251.36 | 108.91 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 308.09 | 86.67 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 392.90 | 98.09 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 454.31 | 139.25 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 470.56 | 197.62 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 414.58 | 246.41 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 339.89 | 330.88 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 362.55 | 206.59 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 231.87 | 86.67 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 470.56 | 385.48 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 346.46 | 382.36 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 470.34 | 286.45 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 393.32 | 253.24 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 288.57 | 188.15 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 232.59 | 150.82 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 251.53 | 108.50 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 308.04 | 86.82 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 392.88 | 98.13 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 454.55 | 138.54 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 471.21 | 195.49 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 415.49 | 243.22 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 340.37 | 328.03 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 363.03 | 204.70 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 232.59 | 86.82 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 471.21 | 382.36 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 346.98 | 379.76 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 471.26 | 283.78 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 394.13 | 250.73 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 290.00 | 184.78 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 234.01 | 148.06 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 252.30 | 107.07 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 308.50 | 85.85 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 393.36 | 96.99 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 455.32 | 136.70 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 472.51 | 192.47 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 416.78 | 239.86 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 340.95 | 325.62 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 363.92 | 202.36 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 234.01 | 85.85 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 472.51 | 379.76 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 698.30 | 741.77 | 754.47 | 538.78 | 215.68 | 0.00 | 0.00 |
February | 948.93 | 551.88 | 961.15 | 691.30 | 269.85 | 0.00 | 0.00 |
March | 793.07 | 487.37 | 859.48 | 482.80 | 376.68 | 0.00 | 0.00 |
April | 586.92 | 354.01 | 690.64 | 330.36 | 360.28 | 0.00 | 0.00 |
May | 475.00 | 282.29 | 613.48 | 203.69 | 409.79 | 0.00 | 0.00 |
June | 507.81 | 205.48 | 609.53 | 177.69 | 431.84 | 0.00 | 0.00 |
July | 617.23 | 165.32 | 657.12 | 242.65 | 414.47 | 0.00 | 0.00 |
August | 787.65 | 186.81 | 781.07 | 393.78 | 387.29 | 0.00 | 0.00 |
September | 914.36 | 263.49 | 866.68 | 531.17 | 335.51 | 0.00 | 0.00 |
October | 952.46 | 369.96 | 905.98 | 626.55 | 279.42 | 0.00 | 0.00 |
November | 840.02 | 464.09 | 825.57 | 597.96 | 227.61 | 0.00 | 0.00 |
December | 686.40 | 635.72 | 717.42 | 517.97 | 199.45 | 0.00 | 0.00 |
Annual Sum or Average | 732.48 | 391.81 | 768.89 | 442.92 | 325.97 | 0.00 | 0.00 |
Minimum of Months | 475.00 | 165.32 | 609.53 | 177.69 | 199.45 | 0.00 | 0.00 |
Maximum of Months | 952.46 | 741.77 | 961.15 | 691.30 | 431.84 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 348.04 | 372.81 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 473.24 | 277.03 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 395.67 | 244.30 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 292.78 | 177.37 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 236.91 | 141.47 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 253.83 | 102.71 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 309.20 | 82.00 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 394.02 | 92.87 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 456.53 | 131.95 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 474.84 | 185.87 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 419.03 | 232.77 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 342.18 | 319.14 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 365.60 | 196.42 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 236.91 | 82.00 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 474.84 | 372.81 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 348.17 | 372.18 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 473.51 | 276.26 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 395.92 | 243.46 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 293.20 | 176.36 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 237.38 | 140.61 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 254.24 | 102.14 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 309.47 | 81.61 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 394.26 | 92.47 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 456.78 | 131.45 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 475.14 | 185.22 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 419.31 | 232.02 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 342.37 | 318.41 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 365.89 | 195.74 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 237.38 | 81.61 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 475.14 | 372.18 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 348.67 | 369.35 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 474.44 | 273.11 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 396.73 | 240.27 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 294.49 | 172.75 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 238.92 | 137.56 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 255.55 | 100.10 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 310.06 | 80.54 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 394.81 | 91.30 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 457.52 | 129.70 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 476.22 | 182.66 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 420.16 | 229.41 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 343.00 | 315.46 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 366.79 | 193.25 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 238.92 | 80.54 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 476.22 | 369.35 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 350.76 | 357.24 | 377.23 | 269.39 | 107.84 | 0.00 | 0.00 |
February | 477.62 | 260.28 | 480.57 | 345.65 | 134.92 | 0.00 | 0.00 |
March | 399.68 | 227.37 | 429.74 | 241.40 | 188.34 | 0.00 | 0.00 |
April | 298.15 | 160.12 | 345.32 | 165.18 | 180.14 | 0.00 | 0.00 |
May | 242.96 | 127.38 | 306.74 | 101.84 | 204.89 | 0.00 | 0.00 |
June | 259.22 | 93.06 | 304.77 | 88.85 | 215.92 | 0.00 | 0.00 |
July | 311.59 | 76.56 | 328.56 | 121.33 | 207.23 | 0.00 | 0.00 |
August | 396.15 | 87.07 | 390.53 | 196.89 | 193.64 | 0.00 | 0.00 |
September | 459.21 | 123.88 | 433.34 | 265.59 | 167.75 | 0.00 | 0.00 |
October | 478.63 | 174.87 | 452.99 | 313.28 | 139.71 | 0.00 | 0.00 |
November | 422.66 | 220.01 | 412.78 | 298.98 | 113.80 | 0.00 | 0.00 |
December | 345.30 | 303.53 | 358.71 | 258.99 | 99.72 | 0.00 | 0.00 |
Annual Sum or Average | 369.39 | 184.04 | 384.44 | 221.46 | 162.98 | 0.00 | 0.00 |
Minimum of Months | 242.96 | 76.56 | 304.77 | 88.85 | 99.72 | 0.00 | 0.00 |
Maximum of Months | 478.63 | 357.24 | 480.57 | 345.65 | 215.92 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.186956E+10 | 0.204125E+10 | 0.202492E+10 | 0.144605E+10 | 0.578876E+09 | 0.00 | 0.00 |
February | 0.229401E+10 | 0.136967E+10 | 0.232999E+10 | 0.167583E+10 | 0.654159E+09 | 0.00 | 0.00 |
March | 0.212603E+10 | 0.133244E+10 | 0.230677E+10 | 0.129580E+10 | 0.101097E+10 | 0.00 | 0.00 |
April | 0.151990E+10 | 0.936488E+09 | 0.179381E+10 | 0.858059E+09 | 0.935756E+09 | 0.00 | 0.00 |
May | 0.126882E+10 | 0.774241E+09 | 0.164651E+10 | 0.546682E+09 | 0.109983E+10 | 0.00 | 0.00 |
June | 0.132214E+10 | 0.529812E+09 | 0.158316E+10 | 0.461522E+09 | 0.112164E+10 | 0.00 | 0.00 |
July | 0.166474E+10 | 0.431894E+09 | 0.176365E+10 | 0.651256E+09 | 0.111240E+10 | 0.00 | 0.00 |
August | 0.211932E+10 | 0.492090E+09 | 0.209631E+10 | 0.105687E+10 | 0.103944E+10 | 0.00 | 0.00 |
September | 0.237622E+10 | 0.681844E+09 | 0.225105E+10 | 0.137963E+10 | 0.871421E+09 | 0.00 | 0.00 |
October | 0.254802E+10 | 0.101197E+10 | 0.243156E+10 | 0.168161E+10 | 0.749950E+09 | 0.00 | 0.00 |
November | 0.217334E+10 | 0.123933E+10 | 0.214427E+10 | 0.155309E+10 | 0.591174E+09 | 0.00 | 0.00 |
December | 0.183616E+10 | 0.174854E+10 | 0.192550E+10 | 0.139020E+10 | 0.535298E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.231183E+11 | 0.125896E+11 | 0.242975E+11 | 0.139966E+11 | 0.103009E+11 | 0.00 | 0.00 |
Minimum of Months | 0.126882E+10 | 0.431894E+09 | 0.158316E+10 | 0.461522E+09 | 0.535298E+09 | 0.00 | 0.00 |
Maximum of Months | 0.254802E+10 | 0.204125E+10 | 0.243156E+10 | 0.168161E+10 | 0.112164E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.926819E+09 | 0.105444E+10 | 0.101246E+10 | 0.723023E+09 | 0.289438E+09 | 0.00 | 0.00 |
February | 0.113576E+10 | 0.716518E+09 | 0.116499E+10 | 0.837915E+09 | 0.327080E+09 | 0.00 | 0.00 |
March | 0.105163E+10 | 0.702952E+09 | 0.115338E+10 | 0.647898E+09 | 0.505485E+09 | 0.00 | 0.00 |
April | 0.744957E+09 | 0.507473E+09 | 0.896907E+09 | 0.429029E+09 | 0.467878E+09 | 0.00 | 0.00 |
May | 0.621589E+09 | 0.414515E+09 | 0.823257E+09 | 0.273341E+09 | 0.549916E+09 | 0.00 | 0.00 |
June | 0.654850E+09 | 0.274810E+09 | 0.791580E+09 | 0.230761E+09 | 0.560820E+09 | 0.00 | 0.00 |
July | 0.831129E+09 | 0.219133E+09 | 0.881826E+09 | 0.325628E+09 | 0.556198E+09 | 0.00 | 0.00 |
August | 0.105741E+10 | 0.250582E+09 | 0.104816E+10 | 0.528435E+09 | 0.519722E+09 | 0.00 | 0.00 |
September | 0.118137E+10 | 0.354730E+09 | 0.112552E+10 | 0.689814E+09 | 0.435711E+09 | 0.00 | 0.00 |
October | 0.126124E+10 | 0.534821E+09 | 0.121578E+10 | 0.840807E+09 | 0.374975E+09 | 0.00 | 0.00 |
November | 0.107363E+10 | 0.653902E+09 | 0.107213E+10 | 0.776547E+09 | 0.295587E+09 | 0.00 | 0.00 |
December | 0.909882E+09 | 0.906016E+09 | 0.962748E+09 | 0.695099E+09 | 0.267649E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.114503E+11 | 0.658989E+10 | 0.121488E+11 | 0.699830E+10 | 0.515046E+10 | 0.00 | 0.00 |
Minimum of Months | 0.621589E+09 | 0.219133E+09 | 0.791580E+09 | 0.230761E+09 | 0.267649E+09 | 0.00 | 0.00 |
Maximum of Months | 0.126124E+10 | 0.105444E+10 | 0.121578E+10 | 0.840807E+09 | 0.560820E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.926820E+09 | 0.103248E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.113612E+10 | 0.700065E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.105180E+10 | 0.685670E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.745599E+09 | 0.495197E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.621038E+09 | 0.409394E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.651523E+09 | 0.282288E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.825183E+09 | 0.232146E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105234E+10 | 0.262722E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.117758E+10 | 0.360944E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.126034E+10 | 0.529294E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.107460E+10 | 0.638687E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.910356E+09 | 0.886231E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.114333E+11 | 0.651512E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.621038E+09 | 0.232146E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.126034E+10 | 0.103248E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.927955E+09 | 0.102410E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.113785E+10 | 0.692972E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.105348E+10 | 0.678275E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.747983E+09 | 0.487673E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.622972E+09 | 0.403961E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.651970E+09 | 0.281221E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.825055E+09 | 0.232546E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105230E+10 | 0.262820E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.117818E+10 | 0.359090E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.126210E+10 | 0.523598E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.107696E+10 | 0.630436E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.911642E+09 | 0.878583E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.114484E+11 | 0.645527E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.622972E+09 | 0.232546E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.126210E+10 | 0.102410E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.929340E+09 | 0.101715E+10 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.114007E+10 | 0.686529E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.105564E+10 | 0.671554E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.751682E+09 | 0.478947E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.626763E+09 | 0.396559E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.653973E+09 | 0.277517E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.826280E+09 | 0.229934E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105359E+10 | 0.259782E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.118019E+10 | 0.354319E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.126556E+10 | 0.515507E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.108028E+10 | 0.621717E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.913213E+09 | 0.872131E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.114766E+11 | 0.638164E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.626763E+09 | 0.229934E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.126556E+10 | 0.101715E+10 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.187034E+10 | 0.198676E+10 | 0.202076E+10 | 0.144308E+10 | 0.577688E+09 | 0.00 | 0.00 |
February | 0.229566E+10 | 0.133510E+10 | 0.232520E+10 | 0.167239E+10 | 0.652816E+09 | 0.00 | 0.00 |
March | 0.212416E+10 | 0.130537E+10 | 0.230203E+10 | 0.129314E+10 | 0.100889E+10 | 0.00 | 0.00 |
April | 0.152129E+10 | 0.917607E+09 | 0.179013E+10 | 0.856297E+09 | 0.933834E+09 | 0.00 | 0.00 |
May | 0.127224E+10 | 0.756079E+09 | 0.164313E+10 | 0.545560E+09 | 0.109757E+10 | 0.00 | 0.00 |
June | 0.131623E+10 | 0.532597E+09 | 0.157991E+10 | 0.460574E+09 | 0.111934E+10 | 0.00 | 0.00 |
July | 0.165318E+10 | 0.442781E+09 | 0.176003E+10 | 0.649918E+09 | 0.111011E+10 | 0.00 | 0.00 |
August | 0.210965E+10 | 0.500340E+09 | 0.209201E+10 | 0.105470E+10 | 0.103731E+10 | 0.00 | 0.00 |
September | 0.237002E+10 | 0.682978E+09 | 0.224643E+10 | 0.137680E+10 | 0.869632E+09 | 0.00 | 0.00 |
October | 0.255106E+10 | 0.990912E+09 | 0.242657E+10 | 0.167816E+10 | 0.748410E+09 | 0.00 | 0.00 |
November | 0.217734E+10 | 0.120291E+10 | 0.213986E+10 | 0.154990E+10 | 0.589960E+09 | 0.00 | 0.00 |
December | 0.183845E+10 | 0.170272E+10 | 0.192154E+10 | 0.138734E+10 | 0.534199E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.230996E+11 | 0.123562E+11 | 0.242476E+11 | 0.139679E+11 | 0.102798E+11 | 0.00 | 0.00 |
Minimum of Months | 0.127224E+10 | 0.442781E+09 | 0.157991E+10 | 0.460574E+09 | 0.534199E+09 | 0.00 | 0.00 |
Maximum of Months | 0.255106E+10 | 0.198676E+10 | 0.242657E+10 | 0.167816E+10 | 0.111934E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.932192E+09 | 0.998538E+09 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.114486E+10 | 0.670192E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.105976E+10 | 0.654324E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.758888E+09 | 0.459745E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.634527E+09 | 0.378904E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.657928E+09 | 0.266221E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.828167E+09 | 0.219628E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105535E+10 | 0.248754E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.118333E+10 | 0.342014E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.127182E+10 | 0.497822E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.108613E+10 | 0.603329E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.916491E+09 | 0.854797E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.115294E+11 | 0.619427E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.634527E+09 | 0.219628E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.127182E+10 | 0.998538E+09 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.932542E+09 | 0.996843E+09 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.114553E+10 | 0.668340E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.106044E+10 | 0.652082E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.759972E+09 | 0.457125E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.635809E+09 | 0.376605E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.658986E+09 | 0.264740E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.828886E+09 | 0.218572E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105599E+10 | 0.247660E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.118397E+10 | 0.340723E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.127262E+10 | 0.496082E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.108686E+10 | 0.601399E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.916991E+09 | 0.852839E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.115386E+11 | 0.617301E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.635809E+09 | 0.218572E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.127262E+10 | 0.996843E+09 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.933882E+09 | 0.989257E+09 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.114777E+10 | 0.660700E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.106261E+10 | 0.643551E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.763316E+09 | 0.447765E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.639926E+09 | 0.368436E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.662392E+09 | 0.259449E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.830472E+09 | 0.215708E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.105746E+10 | 0.244544E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.118590E+10 | 0.336180E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.127550E+10 | 0.489224E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.108906E+10 | 0.594625E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.918678E+09 | 0.844926E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.115670E+11 | 0.609436E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.639926E+09 | 0.215708E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.127550E+10 | 0.989257E+09 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.939465E+09 | 0.956844E+09 | 0.101038E+10 | 0.721538E+09 | 0.288844E+09 | 0.00 | 0.00 |
February | 0.115547E+10 | 0.629677E+09 | 0.116260E+10 | 0.836194E+09 | 0.326408E+09 | 0.00 | 0.00 |
March | 0.107052E+10 | 0.608977E+09 | 0.115101E+10 | 0.646568E+09 | 0.504447E+09 | 0.00 | 0.00 |
April | 0.772797E+09 | 0.415027E+09 | 0.895066E+09 | 0.428148E+09 | 0.466917E+09 | 0.00 | 0.00 |
May | 0.650737E+09 | 0.341174E+09 | 0.821566E+09 | 0.272780E+09 | 0.548787E+09 | 0.00 | 0.00 |
June | 0.671910E+09 | 0.241208E+09 | 0.789955E+09 | 0.230287E+09 | 0.559668E+09 | 0.00 | 0.00 |
July | 0.834559E+09 | 0.205048E+09 | 0.880015E+09 | 0.324959E+09 | 0.555056E+09 | 0.00 | 0.00 |
August | 0.106106E+10 | 0.233220E+09 | 0.104600E+10 | 0.527350E+09 | 0.518655E+09 | 0.00 | 0.00 |
September | 0.119028E+10 | 0.321104E+09 | 0.112321E+10 | 0.688398E+09 | 0.434816E+09 | 0.00 | 0.00 |
October | 0.128196E+10 | 0.468382E+09 | 0.121329E+10 | 0.839080E+09 | 0.374205E+09 | 0.00 | 0.00 |
November | 0.109555E+10 | 0.570255E+09 | 0.106993E+10 | 0.774952E+09 | 0.294980E+09 | 0.00 | 0.00 |
December | 0.924850E+09 | 0.812983E+09 | 0.960771E+09 | 0.693672E+09 | 0.267100E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.116492E+11 | 0.580390E+10 | 0.121238E+11 | 0.698393E+10 | 0.513988E+10 | 0.00 | 0.00 |
Minimum of Months | 0.650737E+09 | 0.205048E+09 | 0.789955E+09 | 0.230287E+09 | 0.267100E+09 | 0.00 | 0.00 |
Maximum of Months | 0.128196E+10 | 0.956844E+09 | 0.121329E+10 | 0.839080E+09 | 0.559668E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -8.8 | -10.8 | -16.1 | 5.70 | -23.3 | 32.48 | 106.19 | 0.00 |
February | -2.2 | -4.9 | -9.9 | 6.21 | -16.1 | 41.31 | 158.25 | 0.00 |
March | 0.30 | -2.8 | -8.4 | 5.38 | -12.8 | 78.62 | 145.02 | 0.00 |
April | 6.67 | 2.37 | -2.9 | 4.89 | -6.2 | 82.10 | 182.32 | 0.01 |
May | 10.10 | 5.18 | 0.22 | 5.28 | -1.1 | 102.67 | 205.47 | 0.01 |
June | 16.46 | 10.04 | 4.91 | 4.56 | 5.04 | 103.05 | 264.47 | 0.02 |
July | 20.57 | 12.44 | 6.56 | 4.24 | 8.00 | 89.47 | 301.47 | 0.00 |
August | 19.17 | 11.02 | 4.61 | 4.29 | 7.18 | 78.96 | 261.05 | 0.00 |
September | 14.69 | 9.07 | 4.37 | 5.43 | 3.41 | 63.03 | 204.21 | 0.00 |
October | 8.64 | 4.13 | -1.0 | 5.38 | -4.2 | 47.64 | 162.42 | 0.00 |
November | 2.84 | -0.8 | -6.9 | 5.91 | -11.0 | 33.00 | 125.52 | 0.00 |
December | -4.1 | -6.4 | -11.1 | 5.64 | -18.2 | 26.54 | 97.81 | 0.00 |
Annual Sum or Average | 7.07 | 2.40 | -2.9 | 5.23 | -5.7 | 65.04 | 184.63 | 0.00 |
Minimum of Months | -8.8 | -10.8 | -16.1 | 4.24 | -23.3 | 26.54 | 97.81 | 0.00 |
Maximum of Months | 20.57 | 12.44 | 6.56 | 6.21 | 8.00 | 103.05 | 301.47 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.60 | 14-JAN-12:00 | 5.15 | -1.1 | 8.20 | -2.3 | 105.00 | 464.50 |
February | 18.90 | 27-FEB-14:00 | 7.20 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 15.00 | 14-MAR-13:20 | 6.65 | -2.4 | 9.30 | 1.23 | 201.67 | 711.67 |
April | 23.30 | 07-APR-13:00 | 9.64 | -4.4 | 9.30 | 4.92 | 314.50 | 110.00 |
May | 30.00 | 20-MAY-15:00 | 15.19 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 32.20 | 29-JUN-12:00 | 14.36 | 0.60 | 9.30 | 17.03 | 187.00 | 729.00 |
July | 37.20 | 17-JUL-15:00 | 17.25 | 4.40 | 4.60 | 20.22 | 119.50 | 797.00 |
August | 35.60 | 05-AUG-15:00 | 17.61 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 34.40 | 02-SEP-14:00 | 16.25 | 4.40 | 7.70 | 20.75 | 95.50 | 789.50 |
October | 25.00 | 18-OCT-13:00 | 11.37 | -1.1 | 7.70 | 7.35 | 48.00 | 913.00 |
November | 17.20 | 04-NOV-13:00 | 8.15 | -1.1 | 11.30 | 2.22 | 81.00 | 689.50 |
December | 13.90 | 10-DEC-01:00 | 5.47 | -5.0 | 13.90 | 5.74 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 10.60 | 5.15 | -7.8 | 4.60 | -2.3 | 0.00 | 0.00 | |
Maximum of Months | 37.20 | 17.61 | 6.70 | 13.90 | 22.47 | 314.50 | 913.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -33.9 | 10-JAN-21:00 | -34.0 | -37.8 | 3.10 | -54.3 | 0.00 | 0.00 |
February | -25.0 | 01-FEB-03:00 | -25.2 | -27.8 | 2.10 | -45.6 | 0.00 | 0.00 |
March | -23.3 | 04-MAR-23:00 | -23.8 | -28.9 | 3.60 | -44.5 | 0.00 | 0.00 |
April | -7.8 | 29-APR-03:00 | -8.6 | -10.6 | 4.10 | -25.6 | 0.00 | 0.00 |
May | -2.8 | 08-MAY-00:10 | -3.3 | -3.9 | 6.18 | -10.2 | 0.00 | 0.00 |
June | 0.60 | 15-JUN-03:00 | -0.4 | -1.7 | 2.60 | -15.7 | 0.00 | 0.00 |
July | 5.60 | 08-JUL-03:00 | 2.98 | 0.00 | 4.10 | -9.2 | 0.00 | 0.00 |
August | 6.70 | 17-AUG-00:00 | 4.32 | 1.70 | 2.60 | -7.1 | 0.00 | 0.00 |
September | 0.00 | 17-SEP-02:00 | -1.5 | -3.9 | 4.10 | -16.8 | 0.00 | 0.00 |
October | -6.1 | 10-OCT-05:19 | -6.6 | -7.8 | 3.77 | -20.6 | 0.00 | 0.00 |
November | -16.7 | 26-NOV-07:00 | -17.3 | -20.6 | 4.60 | -33.8 | 19.50 | 94.00 |
December | -28.3 | 29-DEC-08:00 | -28.5 | -32.2 | 2.10 | -48.7 | 69.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -33.9 | -34.0 | -37.8 | 2.10 | -54.3 | 0.00 | 0.00 | |
Maximum of Months | 6.70 | 4.32 | 1.70 | 6.18 | -7.1 | 69.50 | 94.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.17 | 13-JAN-14:00 | 10.00 | 0.00 | 8.80 | -3.0 | 40.00 | 694.00 |
February | 7.20 | 27-FEB-14:00 | 18.90 | -7.8 | 5.20 | 1.37 | 76.00 | 634.50 |
March | 6.92 | 14-MAR-13:00 | 15.00 | -1.7 | 10.30 | 1.80 | 241.00 | 538.00 |
April | 11.00 | 06-APR-15:00 | 22.20 | 1.10 | 3.60 | 5.33 | 110.00 | 779.00 |
May | 15.19 | 20-MAY-15:00 | 30.00 | 5.60 | 6.70 | 20.57 | 215.50 | 18.50 |
June | 19.18 | 20-JUN-14:00 | 29.40 | 14.40 | 2.60 | 18.28 | 204.00 | 614.00 |
July | 19.19 | 19-JUL-11:00 | 29.40 | 14.40 | 8.80 | 19.52 | 306.50 | 563.50 |
August | 17.61 | 05-AUG-15:00 | 35.60 | 6.70 | 5.20 | 22.47 | 136.50 | 625.50 |
September | 20.11 | 07-SEP-15:20 | 25.17 | 17.93 | 4.10 | 15.88 | 127.67 | 652.00 |
October | 11.58 | 18-OCT-14:00 | 25.00 | -0.6 | 7.70 | 7.55 | 40.50 | 852.00 |
November | 8.87 | 17-NOV-16:00 | 17.20 | 1.10 | 11.30 | 4.10 | 0.00 | 0.00 |
December | 7.61 | 19-DEC-14:00 | 12.80 | 2.80 | 8.20 | 1.37 | 74.00 | 138.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 5.17 | 10.00 | -7.8 | 2.60 | -3.0 | 0.00 | 0.00 | |
Maximum of Months | 20.11 | 35.60 | 17.93 | 11.30 | 22.47 | 306.50 | 852.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.70 | 12-JAN-14:00 | 7.20 | 4.47 | 5.20 | -1.0 | 107.00 | 61.00 |
February | -0.6 | 11-FEB-08:00 | 4.40 | 2.15 | 10.80 | -5.7 | 69.50 | 50.50 |
March | -0.6 | 10-MAR-12:00 | 8.90 | 4.49 | 10.30 | -2.3 | 253.00 | 140.50 |
April | 6.10 | 17-APR-16:19 | 7.97 | 6.96 | 4.50 | 0.84 | 201.50 | 117.50 |
May | 12.20 | 02-MAY-12:00 | 18.90 | 14.60 | 12.90 | 14.84 | 108.50 | 934.50 |
June | 15.60 | 20-JUN-19:00 | 25.60 | 18.75 | 3.60 | 20.22 | 17.50 | 17.00 |
July | 16.70 | 18-JUL-21:00 | 19.40 | 17.51 | 4.10 | 16.49 | 0.00 | 0.00 |
August | 11.10 | 08-AUG-11:00 | 26.70 | 16.73 | 2.60 | 12.03 | 134.50 | 869.00 |
September | 18.30 | 07-SEP-14:00 | 24.40 | 20.09 | 4.10 | 15.57 | 111.00 | 720.00 |
October | 6.70 | 01-OCT-14:09 | 9.08 | 7.77 | 2.10 | 4.06 | 260.33 | 0.33 |
November | 3.30 | 16-NOV-19:00 | 10.60 | 6.87 | 9.80 | -1.7 | 0.00 | 0.00 |
December | 2.80 | 19-DEC-14:09 | 10.97 | 6.80 | 10.78 | -1.0 | 95.00 | 292.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.6 | 4.40 | 2.15 | 2.10 | -5.7 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 26.70 | 20.09 | 12.90 | 20.22 | 260.33 | 934.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 5.41 | 12.59 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 4.46 | 20.37 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 5.03 | 30.19 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 7.01 | 37.07 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 9.90 | 46.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 12.91 | 55.45 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 15.24 | 57.38 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 16.26 | 48.01 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 15.67 | 34.51 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.64 | 22.84 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 10.74 | 14.52 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 7.74 | 10.24 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 10.37 | 32.53 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 4.46 | 10.24 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 16.26 | 57.38 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.388428E+09 | -263100301.1 | 0.00 | 0.00 | 744.00 | 0.00 | -125327750.8 | 59.00 | 0.00 | 0.00 |
February | 0.355487E+09 | -243118716.9 | 0.00 | 0.00 | 672.00 | 0.00 | -112367824.8 | 58.99 | 0.00 | 0.00 |
March | 0.394707E+09 | -270541847.7 | 0.00 | 0.00 | 744.00 | 0.00 | -124165023.8 | 58.99 | 0.00 | 0.00 |
April | 0.367381E+09 | -249357697.3 | 0.00 | 0.00 | 720.00 | 0.00 | -118023204.5 | 58.99 | 0.00 | 0.00 |
May | 0.362818E+09 | -243585222.7 | 0.00 | 0.00 | 744.00 | 0.00 | -119233246.5 | 58.99 | 0.00 | 0.00 |
June | 0.333851E+09 | -223294778.8 | 0.00 | 0.00 | 720.00 | 0.00 | -110556227.6 | 58.99 | 0.00 | 0.00 |
July | 0.327787E+09 | -214924360.3 | 0.00 | 0.00 | 744.00 | 0.00 | -112862309.4 | 58.99 | 0.00 | 0.00 |
August | 0.327177E+09 | -214079980.6 | 0.00 | 0.00 | 744.00 | 0.00 | -113097265.8 | 58.99 | 0.00 | 0.00 |
September | 0.319433E+09 | -207988521.9 | 0.00 | 0.00 | 720.00 | 0.00 | -111443985.5 | 58.99 | 0.00 | 0.00 |
October | 0.341088E+09 | -222682411.5 | 0.00 | 0.00 | 744.00 | 0.00 | -118406008.0 | 59.00 | 0.00 | 0.00 |
November | 0.347216E+09 | -228627914.8 | 0.00 | 0.00 | 720.00 | 0.00 | -118588117.7 | 58.99 | 0.00 | 0.00 |
December | 0.376477E+09 | -251950833.7 | 0.00 | 0.00 | 744.00 | 0.00 | -124526575.5 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.424185E+10 | -.283325E+10 | 8760.00 | -.140860E+10 | 58.99 | |||||
Minimum of Months | 0.319433E+09 | -270541847.7 | 0.00 | 0.00 | 672.00 | 0.00 | -125327750.8 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.394707E+09 | -207988521.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110556227.6 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.386607E+09 | -263102377.7 | 0.00 | 0.00 | 744.00 | 0.00 | -123504939.2 | 58.99 | 0.00 | 0.00 |
February | 0.353196E+09 | -243119159.2 | 0.00 | 0.00 | 672.00 | 0.00 | -110077245.4 | 58.99 | 0.00 | 0.00 |
March | 0.392038E+09 | -270545693.7 | 0.00 | 0.00 | 744.00 | 0.00 | -121492266.3 | 58.99 | 0.00 | 0.00 |
April | 0.363829E+09 | -249344938.4 | 0.00 | 0.00 | 720.00 | 0.00 | -114484442.5 | 58.99 | 0.00 | 0.00 |
May | 0.360227E+09 | -243582288.9 | 0.00 | 0.00 | 744.00 | 0.00 | -116644798.7 | 58.99 | 0.00 | 0.00 |
June | 0.332959E+09 | -223291942.3 | 0.00 | 0.00 | 720.00 | 0.00 | -109666801.3 | 58.99 | 0.00 | 0.00 |
July | 0.327577E+09 | -214925541.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112651571.8 | 58.99 | 0.00 | 0.00 |
August | 0.326822E+09 | -214078852.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112743584.7 | 58.99 | 0.00 | 0.00 |
September | 0.318113E+09 | -207992577.1 | 0.00 | 0.00 | 720.00 | 0.00 | -110120908.7 | 58.99 | 0.00 | 0.00 |
October | 0.338214E+09 | -222683063.5 | 0.00 | 0.00 | 744.00 | 0.00 | -115531013.2 | 58.99 | 0.00 | 0.00 |
November | 0.344189E+09 | -228630376.7 | 0.00 | 0.00 | 720.00 | 0.00 | -115558207.3 | 58.99 | 0.00 | 0.00 |
December | 0.374483E+09 | -251965991.4 | 0.00 | 0.00 | 744.00 | 0.00 | -122517286.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.421826E+10 | -.283326E+10 | 8760.00 | -.138499E+10 | 58.99 | |||||
Minimum of Months | 0.318113E+09 | -270545693.7 | 0.00 | 0.00 | 672.00 | 0.00 | -123504939.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.392038E+09 | -207992577.1 | 0.00 | 0.00 | 744.00 | 0.00 | -109666801.3 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.356736E+09 | -231377424.4 | 0.00 | 0.00 | 744.00 | 0.00 | -125358262.5 | 58.99 | 0.00 | 0.00 |
February | 0.325616E+09 | -213951196.7 | 0.00 | 0.00 | 672.00 | 0.00 | -111665218.8 | 58.99 | 0.00 | 0.00 |
March | 0.364849E+09 | -241643236.8 | 0.00 | 0.00 | 744.00 | 0.00 | -123206238.3 | 58.99 | 0.00 | 0.00 |
April | 0.335025E+09 | -219124311.4 | 0.00 | 0.00 | 720.00 | 0.00 | -115900679.3 | 58.99 | 0.00 | 0.00 |
May | 0.333194E+09 | -216058260.7 | 0.00 | 0.00 | 744.00 | 0.00 | -117135609.4 | 58.99 | 0.00 | 0.00 |
June | 0.307767E+09 | -199008093.9 | 0.00 | 0.00 | 720.00 | 0.00 | -108758872.7 | 58.99 | 0.00 | 0.00 |
July | 0.298718E+09 | -187740207.5 | 0.00 | 0.00 | 744.00 | 0.00 | -110977946.7 | 58.99 | 0.00 | 0.00 |
August | 0.302683E+09 | -191355503.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111327610.0 | 58.99 | 0.00 | 0.00 |
September | 0.292103E+09 | -182665515.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109437499.6 | 58.99 | 0.00 | 0.00 |
October | 0.312075E+09 | -195843160.8 | 0.00 | 0.00 | 744.00 | 0.00 | -116231428.4 | 59.00 | 0.00 | 0.00 |
November | 0.319006E+09 | -201866663.6 | 0.00 | 0.00 | 720.00 | 0.00 | -117138993.5 | 58.99 | 0.00 | 0.00 |
December | 0.344243E+09 | -219928990.5 | 0.00 | 0.00 | 744.00 | 0.00 | -124314104.5 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.389202E+10 | -.250056E+10 | 8760.00 | -.139145E+10 | 58.99 | |||||
Minimum of Months | 0.292103E+09 | -241643236.8 | 0.00 | 0.00 | 672.00 | 0.00 | -125358262.5 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.364849E+09 | -182665515.9 | 0.00 | 0.00 | 744.00 | 0.00 | -108758872.7 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.357188E+09 | -231353266.5 | 0.00 | 0.00 | 744.00 | 0.00 | -125834348.9 | 59.00 | 0.00 | 0.00 |
February | 0.326054E+09 | -213966193.9 | 0.00 | 0.00 | 672.00 | 0.00 | -112087920.4 | 58.99 | 0.00 | 0.00 |
March | 0.365297E+09 | -241633879.3 | 0.00 | 0.00 | 744.00 | 0.00 | -123662817.8 | 58.99 | 0.00 | 0.00 |
April | 0.335570E+09 | -219135365.9 | 0.00 | 0.00 | 720.00 | 0.00 | -116434721.8 | 58.99 | 0.00 | 0.00 |
May | 0.333587E+09 | -216045341.3 | 0.00 | 0.00 | 744.00 | 0.00 | -117541450.6 | 59.00 | 0.00 | 0.00 |
June | 0.307840E+09 | -198994407.4 | 0.00 | 0.00 | 720.00 | 0.00 | -108846031.3 | 59.00 | 0.00 | 0.00 |
July | 0.298687E+09 | -187732746.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110953756.7 | 58.99 | 0.00 | 0.00 |
August | 0.302681E+09 | -191354769.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111326358.2 | 58.99 | 0.00 | 0.00 |
September | 0.292235E+09 | -182667093.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109567863.7 | 58.99 | 0.00 | 0.00 |
October | 0.312477E+09 | -195843203.7 | 0.00 | 0.00 | 744.00 | 0.00 | -116633779.9 | 59.00 | 0.00 | 0.00 |
November | 0.319562E+09 | -201875246.0 | 0.00 | 0.00 | 720.00 | 0.00 | -117686541.5 | 58.99 | 0.00 | 0.00 |
December | 0.344675E+09 | -219917060.9 | 0.00 | 0.00 | 744.00 | 0.00 | -124757515.4 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.389585E+10 | -.250052E+10 | 8760.00 | -.139533E+10 | 58.99 | |||||
Minimum of Months | 0.292235E+09 | -241633879.3 | 0.00 | 0.00 | 672.00 | 0.00 | -125834348.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.365297E+09 | -182667093.9 | 0.00 | 0.00 | 744.00 | 0.00 | -108846031.3 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.346169E+09 | -218673869.1 | 0.00 | 0.00 | 744.00 | 0.00 | -127495072.9 | 58.99 | 0.00 | 0.00 |
February | 0.316160E+09 | -202327645.2 | 0.00 | 0.00 | 672.00 | 0.00 | -113832468.2 | 59.00 | 0.00 | 0.00 |
March | 0.353939E+09 | -228639867.6 | 0.00 | 0.00 | 744.00 | 0.00 | -125298726.3 | 58.99 | 0.00 | 0.00 |
April | 0.326301E+09 | -207357137.5 | 0.00 | 0.00 | 720.00 | 0.00 | -118943786.7 | 58.99 | 0.00 | 0.00 |
May | 0.324272E+09 | -204327838.5 | 0.00 | 0.00 | 744.00 | 0.00 | -119943997.2 | 58.99 | 0.00 | 0.00 |
June | 0.298529E+09 | -188310290.2 | 0.00 | 0.00 | 720.00 | 0.00 | -110219097.1 | 58.99 | 0.00 | 0.00 |
July | 0.289443E+09 | -177558024.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111884848.1 | 58.99 | 0.00 | 0.00 |
August | 0.293461E+09 | -181026109.3 | 0.00 | 0.00 | 744.00 | 0.00 | -112435383.0 | 59.01 | 0.00 | 0.00 |
September | 0.283979E+09 | -172851980.6 | 0.00 | 0.00 | 720.00 | 0.00 | -111126659.8 | 58.99 | 0.00 | 0.00 |
October | 0.304324E+09 | -185118864.2 | 0.00 | 0.00 | 744.00 | 0.00 | -119205380.6 | 58.99 | 0.00 | 0.00 |
November | 0.310602E+09 | -190661374.9 | 0.00 | 0.00 | 720.00 | 0.00 | -119940209.8 | 58.99 | 0.00 | 0.00 |
December | 0.334282E+09 | -207997337.6 | 0.00 | 0.00 | 744.00 | 0.00 | -126284281.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.378146E+10 | -.236485E+10 | 8760.00 | -.141661E+10 | 58.99 | |||||
Minimum of Months | 0.283979E+09 | -228639867.6 | 0.00 | 0.00 | 672.00 | 0.00 | -127495072.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.353939E+09 | -172851980.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110219097.1 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.346094E+09 | -218673877.8 | 0.00 | 0.00 | 744.00 | 0.00 | -127419864.5 | 58.99 | 0.00 | 0.00 |
February | 0.316078E+09 | -202328676.7 | 0.00 | 0.00 | 672.00 | 0.00 | -113749162.8 | 58.99 | 0.00 | 0.00 |
March | 0.353922E+09 | -228639286.2 | 0.00 | 0.00 | 744.00 | 0.00 | -125282843.4 | 58.99 | 0.00 | 0.00 |
April | 0.326102E+09 | -207354051.8 | 0.00 | 0.00 | 720.00 | 0.00 | -118747465.2 | 59.00 | 0.00 | 0.00 |
May | 0.324006E+09 | -204325845.0 | 0.00 | 0.00 | 744.00 | 0.00 | -119679929.5 | 58.99 | 0.00 | 0.00 |
June | 0.298375E+09 | -188308177.5 | 0.00 | 0.00 | 720.00 | 0.00 | -110066888.5 | 58.99 | 0.00 | 0.00 |
July | 0.289499E+09 | -177530065.6 | 0.00 | 0.00 | 744.00 | 0.00 | -111969292.0 | 59.00 | 0.00 | 0.00 |
August | 0.293451E+09 | -181076893.8 | 0.00 | 0.00 | 744.00 | 0.00 | -112374486.5 | 58.99 | 0.00 | 0.00 |
September | 0.283771E+09 | -172882908.0 | 0.00 | 0.00 | 720.00 | 0.00 | -110888355.4 | 58.98 | 0.00 | 0.00 |
October | 0.303921E+09 | -185107685.2 | 0.00 | 0.00 | 744.00 | 0.00 | -118813306.8 | 58.99 | 0.00 | 0.00 |
November | 0.310481E+09 | -190665455.9 | 0.00 | 0.00 | 720.00 | 0.00 | -119815076.4 | 58.99 | 0.00 | 0.00 |
December | 0.334246E+09 | -207993342.4 | 0.00 | 0.00 | 744.00 | 0.00 | -126252897.5 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.377995E+10 | -.236489E+10 | 8760.00 | -.141506E+10 | 58.99 | |||||
Minimum of Months | 0.283771E+09 | -228639286.2 | 0.00 | 0.00 | 672.00 | 0.00 | -127419864.5 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.353922E+09 | -172882908.0 | 0.00 | 0.00 | 744.00 | 0.00 | -110066888.5 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.346177E+09 | -218673750.3 | 0.00 | 0.00 | 744.00 | 0.00 | -127503388.0 | 58.99 | 0.00 | 0.00 |
February | 0.316193E+09 | -202328447.1 | 0.00 | 0.00 | 672.00 | 0.00 | -113864672.1 | 59.00 | 0.00 | 0.00 |
March | 0.354045E+09 | -228639679.1 | 0.00 | 0.00 | 744.00 | 0.00 | -125405600.1 | 58.99 | 0.00 | 0.00 |
April | 0.326277E+09 | -207356192.9 | 0.00 | 0.00 | 720.00 | 0.00 | -118921194.9 | 58.99 | 0.00 | 0.00 |
May | 0.324186E+09 | -204327536.5 | 0.00 | 0.00 | 744.00 | 0.00 | -119858654.7 | 58.99 | 0.00 | 0.00 |
June | 0.298495E+09 | -188310163.7 | 0.00 | 0.00 | 720.00 | 0.00 | -110184580.7 | 58.99 | 0.00 | 0.00 |
July | 0.289567E+09 | -177566228.7 | 0.00 | 0.00 | 744.00 | 0.00 | -112000433.3 | 58.98 | 0.00 | 0.00 |
August | 0.293538E+09 | -181030869.3 | 0.00 | 0.00 | 744.00 | 0.00 | -112506699.6 | 59.00 | 0.00 | 0.00 |
September | 0.283866E+09 | -172861841.9 | 0.00 | 0.00 | 720.00 | 0.00 | -111004598.7 | 58.99 | 0.00 | 0.00 |
October | 0.304057E+09 | -185117186.2 | 0.00 | 0.00 | 744.00 | 0.00 | -118940090.2 | 58.99 | 0.00 | 0.00 |
November | 0.310601E+09 | -190669592.8 | 0.00 | 0.00 | 720.00 | 0.00 | -119931696.7 | 58.99 | 0.00 | 0.00 |
December | 0.334350E+09 | -207987766.7 | 0.00 | 0.00 | 744.00 | 0.00 | -126362238.6 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.378135E+10 | -.236487E+10 | 8760.00 | -.141648E+10 | 58.99 | |||||
Minimum of Months | 0.283866E+09 | -228639679.1 | 0.00 | 0.00 | 672.00 | 0.00 | -127503388.0 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.354045E+09 | -172861841.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110184580.7 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 226.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 275.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 304.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 325.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 385.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 434.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 417.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 421.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 352.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 317.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 269.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 236.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3965.83 | ||||||||||
Minimum of Months | 226.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 434.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.270584E+11 | 58604.93 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153701E+11 | 58604.93 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.128947E+11 | 58604.93 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.509228E+10 | 58604.93 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.305441E+10 | 58604.93 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 95880957.22 | 7466.12 | 16-JUN-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.467012E+09 | 49065.51 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.179861E+10 | 58604.93 | 10-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.856422E+10 | 58604.93 | 10-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.197394E+11 | 58604.93 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.941351E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.270584E+11 | 58604.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.888797E+10 | 31528.53 | 04-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.451253E+10 | 31528.53 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.296720E+10 | 31528.53 | 03-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.817500E+09 | 31528.53 | 29-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.503701E+09 | 31528.53 | 08-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 8968093.34 | 1530.90 | 19-SEP-08:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.208938E+09 | 13077.92 | 10-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.198083E+10 | 31528.53 | 14-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.583605E+10 | 31528.53 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.257237E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.888797E+10 | 31528.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.100217E+11 | 31306.64 | 06-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.532330E+10 | 31306.64 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.378327E+10 | 31306.64 | 04-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.112750E+10 | 31306.64 | 29-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.725269E+09 | 31306.64 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 26281046.40 | 3480.81 | 19-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.371836E+09 | 16178.48 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.254746E+10 | 31306.64 | 13-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.689748E+10 | 31306.64 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.308241E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.100217E+11 | 31306.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.102938E+11 | 31812.13 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.551753E+10 | 31812.13 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.400673E+10 | 31812.13 | 03-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.124730E+10 | 31812.13 | 29-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.803485E+09 | 31812.13 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 38270137.68 | 3425.69 | 20-SEP-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.429416E+09 | 22465.11 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.272424E+10 | 31812.13 | 13-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.715065E+10 | 31812.13 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.322114E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.102938E+11 | 31812.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.107378E+11 | 31070.23 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.585843E+10 | 31070.23 | 01-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.439441E+10 | 31070.23 | 03-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.149273E+10 | 31070.23 | 29-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.944576E+09 | 31070.23 | 01-MAY-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1296847.16 | 604.07 | 16-JUN-11:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 70811452.15 | 4317.14 | 20-SEP-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.531704E+09 | 27621.65 | 10-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.301471E+10 | 31070.23 | 12-NOV-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.756405E+10 | 31070.23 | 01-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.346105E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.107378E+11 | 31070.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.225175E+11 | 57156.20 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.131117E+11 | 57156.20 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.108840E+11 | 57156.20 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.461598E+10 | 57156.20 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.294387E+10 | 57156.20 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.101704E+09 | 6261.24 | 16-JUN-08:18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.542986E+09 | 49601.07 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.201468E+10 | 57156.20 | 08-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.790505E+10 | 57156.20 | 10-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.167109E+11 | 57156.20 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.813483E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.225175E+11 | 57156.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.111489E+11 | 28531.97 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.629805E+10 | 28531.97 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.501649E+10 | 28531.97 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.195305E+10 | 28531.97 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.123890E+10 | 28531.97 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 25548090.89 | 1898.80 | 16-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.180397E+09 | 25217.30 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.777133E+09 | 28531.97 | 08-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.356219E+10 | 28531.97 | 10-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.807554E+10 | 28531.97 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.382762E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.111489E+11 | 28531.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.112480E+11 | 28909.66 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.639083E+10 | 28909.66 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.513552E+10 | 28909.66 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.204135E+10 | 28909.66 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.129254E+10 | 28909.66 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 29409819.95 | 1981.98 | 16-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.194576E+09 | 27008.81 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.813538E+09 | 28909.66 | 08-OCT-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.364943E+10 | 28909.66 | 10-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.817973E+10 | 28909.66 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.389749E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.112480E+11 | 28909.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.116748E+11 | 28668.46 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.676257E+10 | 28668.46 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.557316E+10 | 28668.46 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.236352E+10 | 28668.46 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.149083E+10 | 28668.46 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 47084748.85 | 6311.21 | 17-JUN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.246090E+09 | 28668.46 | 20-SEP-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.940108E+09 | 28668.46 | 05-OCT-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.394724E+10 | 28668.46 | 03-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.858047E+10 | 28668.46 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.416259E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.116748E+11 | 28668.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.140124E+11 | 30713.35 | 01-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.832833E+10 | 30713.35 | 01-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.723330E+10 | 30713.35 | 01-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.340533E+10 | 30713.35 | 01-APR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.211808E+10 | 30713.35 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.106629E+09 | 26796.18 | 17-JUN-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 10144317.41 | 6955.36 | 18-AUG-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.397137E+09 | 30713.35 | 19-SEP-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.128317E+10 | 30713.35 | 04-OCT-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.486253E+10 | 30713.35 | 01-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.101779E+11 | 30713.35 | 01-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.519349E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.140124E+11 | 30713.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 517.58 | 517.58 | 0.15 | 27-FEB-15:30 | 0.15 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 36535100.73 | 36535100.73 | 3292.22 | 07-APR-14:00 | 3292.22 | 0.00 |
May | 0.00 | 0.00 | 0.144806E+10 | 0.143719E+10 | 12347.37 | 20-MAY-16:10 | 12347.37 | 0.00 |
June | 0.00 | 0.00 | 0.634181E+10 | 0.601172E+10 | 15773.47 | 20-JUN-17:00 | 13175.80 | 0.00 |
July | 0.00 | 0.00 | 0.129984E+11 | 0.125997E+11 | 32430.16 | 19-JUL-07:03 | 21764.01 | 0.00 |
August | 0.00 | 0.00 | 0.105700E+11 | 0.104825E+11 | 29776.03 | 07-AUG-07:02 | 29776.03 | 0.00 |
September | 0.00 | 0.00 | 0.578338E+10 | 0.543364E+10 | 30117.99 | 05-SEP-07:02 | 26518.73 | 0.00 |
October | 0.00 | 0.00 | 0.584933E+09 | 0.584933E+09 | 10214.84 | 18-OCT-14:00 | 10214.84 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.377632E+11 | 0.365862E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.129984E+11 | 0.125997E+11 | 32430.16 | 29776.03 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 1475374.14 | 1475374.14 | 444.46 | 28-FEB-22:40 | 444.46 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 83060944.73 | 83060944.73 | 16354.29 | 06-APR-20:02 | 16354.29 | 0.00 |
May | 0.00 | 0.00 | 0.125384E+10 | 0.124679E+10 | 16666.00 | 20-MAY-18:17 | 16666.00 | 0.00 |
June | 0.00 | 0.00 | 0.441773E+10 | 0.425782E+10 | 17452.78 | 21-JUN-20:02 | 14093.61 | 0.00 |
July | 0.00 | 0.00 | 0.828962E+10 | 0.809720E+10 | 17939.93 | 18-JUL-22:00 | 10391.39 | 0.00 |
August | 0.00 | 0.00 | 0.686328E+10 | 0.682824E+10 | 16891.10 | 08-AUG-22:44 | 15738.71 | 0.00 |
September | 0.00 | 0.00 | 0.370729E+10 | 0.353520E+10 | 17733.61 | 06-SEP-20:02 | 12413.30 | 0.00 |
October | 0.00 | 0.00 | 0.444489E+09 | 0.444489E+09 | 16354.29 | 02-OCT-20:02 | 16354.29 | 0.00 |
November | 0.00 | 0.00 | 6215933.25 | 6215933.25 | 16354.29 | 04-NOV-19:22 | 16354.29 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.250670E+11 | 0.245005E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.828962E+10 | 0.809720E+10 | 17939.93 | 16666.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 1661.22 | 1661.22 | 0.17 | 27-FEB-11:50 | 0.17 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 47467491.99 | 47467491.99 | 3148.49 | 07-APR-14:00 | 3148.49 | 0.00 |
May | 0.00 | 0.00 | 0.767575E+09 | 0.766677E+09 | 7612.71 | 20-MAY-16:00 | 7612.71 | 0.00 |
June | 0.00 | 0.00 | 0.321566E+10 | 0.312020E+10 | 12503.20 | 22-JUN-06:03 | 8548.18 | 0.00 |
July | 0.00 | 0.00 | 0.621007E+10 | 0.610376E+10 | 17896.81 | 19-JUL-06:03 | 12134.61 | 0.00 |
August | 0.00 | 0.00 | 0.513884E+10 | 0.512097E+10 | 16573.33 | 06-AUG-07:03 | 16573.33 | 0.00 |
September | 0.00 | 0.00 | 0.261045E+10 | 0.248991E+10 | 17150.13 | 07-SEP-06:02 | 10898.64 | 0.00 |
October | 0.00 | 0.00 | 0.348474E+09 | 0.348474E+09 | 6534.93 | 18-OCT-14:00 | 6534.93 | 0.00 |
November | 0.00 | 0.00 | 15855.87 | 15855.87 | 23.18 | 04-NOV-11:30 | 23.18 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.183385E+11 | 0.179975E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.621007E+10 | 0.610376E+10 | 17896.81 | 16573.33 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 909.54 | 909.54 | 0.13 | 27-FEB-15:30 | 0.13 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 41079181.07 | 41079181.07 | 2994.38 | 07-APR-14:00 | 2994.38 | 0.00 |
May | 0.00 | 0.00 | 0.742872E+09 | 0.742060E+09 | 7559.91 | 20-MAY-16:00 | 7559.91 | 0.00 |
June | 0.00 | 0.00 | 0.319541E+10 | 0.310085E+10 | 12319.97 | 22-JUN-06:03 | 8427.50 | 0.00 |
July | 0.00 | 0.00 | 0.622822E+10 | 0.612123E+10 | 17967.20 | 19-JUL-06:03 | 12190.65 | 0.00 |
August | 0.00 | 0.00 | 0.514620E+10 | 0.512837E+10 | 16724.16 | 06-AUG-07:03 | 16724.16 | 0.00 |
September | 0.00 | 0.00 | 0.260312E+10 | 0.248224E+10 | 17217.71 | 07-SEP-06:02 | 10947.99 | 0.00 |
October | 0.00 | 0.00 | 0.325677E+09 | 0.325677E+09 | 6442.51 | 18-OCT-14:00 | 6442.51 | 0.00 |
November | 0.00 | 0.00 | 1256.77 | 1256.77 | 0.18 | 04-NOV-14:00 | 0.18 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.182826E+11 | 0.179415E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.622822E+10 | 0.612123E+10 | 17967.20 | 16724.16 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 575.71 | 575.71 | 0.11 | 27-FEB-15:30 | 0.11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 29531651.48 | 29531651.48 | 2618.87 | 07-APR-14:00 | 2618.87 | 0.00 |
May | 0.00 | 0.00 | 0.673444E+09 | 0.672829E+09 | 7304.06 | 20-MAY-16:00 | 7304.06 | 0.00 |
June | 0.00 | 0.00 | 0.305442E+10 | 0.296445E+10 | 9506.61 | 22-JUN-06:03 | 6541.27 | 0.00 |
July | 0.00 | 0.00 | 0.604363E+10 | 0.594141E+10 | 17762.28 | 19-JUL-06:03 | 12022.48 | 0.00 |
August | 0.00 | 0.00 | 0.497750E+10 | 0.496123E+10 | 16367.37 | 07-AUG-06:02 | 16367.37 | 0.00 |
September | 0.00 | 0.00 | 0.250109E+10 | 0.238375E+10 | 17021.44 | 07-SEP-06:02 | 10796.68 | 0.00 |
October | 0.00 | 0.00 | 0.283255E+09 | 0.283255E+09 | 6159.81 | 18-OCT-14:00 | 6159.81 | 0.00 |
November | 0.00 | 0.00 | 5099.40 | 5099.40 | 6.82 | 04-NOV-12:30 | 6.82 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.175629E+11 | 0.172365E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.604363E+10 | 0.594141E+10 | 17762.28 | 16367.37 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 14472416.40 | 14472416.40 | 2201.40 | 07-APR-14:10 | 2201.40 | 0.00 |
May | 0.00 | 0.00 | 0.850632E+09 | 0.845525E+09 | 11222.10 | 20-MAY-16:00 | 11222.10 | 0.00 |
June | 0.00 | 0.00 | 0.461905E+10 | 0.438934E+10 | 14447.79 | 29-JUN-15:00 | 14447.79 | 0.00 |
July | 0.00 | 0.00 | 0.946307E+10 | 0.920463E+10 | 31179.63 | 19-JUL-07:03 | 21546.46 | 0.00 |
August | 0.00 | 0.00 | 0.782306E+10 | 0.776266E+10 | 29240.19 | 06-AUG-08:62 | 29240.19 | 0.00 |
September | 0.00 | 0.00 | 0.393415E+10 | 0.366262E+10 | 29291.39 | 06-SEP-07:02 | 19441.00 | 0.00 |
October | 0.00 | 0.00 | 0.357721E+09 | 0.357721E+09 | 8856.70 | 18-OCT-14:30 | 8856.70 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.270622E+11 | 0.262370E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.946307E+10 | 0.920463E+10 | 31179.63 | 29240.19 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 676217.84 | 676217.84 | 251.86 | 27-FEB-15:20 | 251.86 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 48183032.35 | 48183032.35 | 1893.52 | 07-APR-14:10 | 1893.52 | 0.00 |
May | 0.00 | 0.00 | 0.716223E+09 | 0.716192E+09 | 6395.55 | 20-MAY-16:00 | 6395.55 | 0.00 |
June | 0.00 | 0.00 | 0.322498E+10 | 0.312781E+10 | 8016.82 | 29-JUN-15:00 | 8016.82 | 0.00 |
July | 0.00 | 0.00 | 0.582918E+10 | 0.573130E+10 | 16014.74 | 19-JUL-07:03 | 13225.52 | 0.00 |
August | 0.00 | 0.00 | 0.513629E+10 | 0.511785E+10 | 15219.57 | 08-AUG-07:03 | 15219.57 | 0.00 |
September | 0.00 | 0.00 | 0.280434E+10 | 0.267247E+10 | 15977.66 | 07-SEP-07:02 | 13147.02 | 0.00 |
October | 0.00 | 0.00 | 0.457255E+09 | 0.457255E+09 | 5265.35 | 18-OCT-14:40 | 5265.35 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.182171E+11 | 0.178717E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.582918E+10 | 0.573130E+10 | 16014.74 | 15219.57 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 245109.95 | 245109.95 | 114.54 | 27-FEB-15:40 | 114.54 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 42852589.04 | 42852589.04 | 1809.99 | 07-APR-14:10 | 1809.99 | 0.00 |
May | 0.00 | 0.00 | 0.680621E+09 | 0.680584E+09 | 6294.30 | 20-MAY-16:00 | 6294.30 | 0.00 |
June | 0.00 | 0.00 | 0.313344E+10 | 0.303760E+10 | 7935.97 | 29-JUN-15:00 | 7935.97 | 0.00 |
July | 0.00 | 0.00 | 0.573374E+10 | 0.563715E+10 | 15863.56 | 19-JUL-07:03 | 13070.09 | 0.00 |
August | 0.00 | 0.00 | 0.504555E+10 | 0.502728E+10 | 15065.36 | 08-AUG-07:03 | 15065.36 | 0.00 |
September | 0.00 | 0.00 | 0.274846E+10 | 0.261800E+10 | 15828.09 | 07-SEP-07:02 | 12991.13 | 0.00 |
October | 0.00 | 0.00 | 0.436351E+09 | 0.436351E+09 | 5179.09 | 18-OCT-14:40 | 5179.09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.178213E+11 | 0.174801E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.573374E+10 | 0.563715E+10 | 15863.56 | 15065.36 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 29290976.72 | 29290976.72 | 1521.39 | 07-APR-14:10 | 1521.39 | 0.00 |
May | 0.00 | 0.00 | 0.583872E+09 | 0.583837E+09 | 6042.43 | 20-MAY-16:00 | 6042.43 | 0.00 |
June | 0.00 | 0.00 | 0.288833E+10 | 0.279755E+10 | 7766.99 | 29-JUN-15:00 | 7766.99 | 0.00 |
July | 0.00 | 0.00 | 0.551650E+10 | 0.542479E+10 | 15378.38 | 16-JUL-08:62 | 13929.61 | 0.00 |
August | 0.00 | 0.00 | 0.483572E+10 | 0.481851E+10 | 14666.74 | 07-AUG-07:02 | 14666.74 | 0.00 |
September | 0.00 | 0.00 | 0.260891E+10 | 0.248198E+10 | 15294.38 | 06-SEP-07:02 | 13931.14 | 0.00 |
October | 0.00 | 0.00 | 0.373610E+09 | 0.373610E+09 | 4925.96 | 18-OCT-14:40 | 4925.96 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.168362E+11 | 0.165096E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.551650E+10 | 0.542479E+10 | 15378.38 | 14666.74 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 802547.46 | 802547.46 | 459.22 | 07-APR-14:00 | 459.22 | 0.00 |
May | 0.00 | 0.00 | 0.364570E+09 | 0.364367E+09 | 5800.39 | 20-MAY-16:00 | 5800.39 | 0.00 |
June | 0.00 | 0.00 | 0.225718E+10 | 0.217738E+10 | 7728.11 | 29-JUN-15:00 | 7728.11 | 0.00 |
July | 0.00 | 0.00 | 0.499083E+10 | 0.490560E+10 | 16457.47 | 17-JUL-07:02 | 14981.17 | 0.00 |
August | 0.00 | 0.00 | 0.406937E+10 | 0.405818E+10 | 13812.57 | 07-AUG-07:02 | 13812.57 | 0.00 |
September | 0.00 | 0.00 | 0.193289E+10 | 0.183439E+10 | 16288.68 | 04-SEP-08:62 | 16288.68 | 0.00 |
October | 0.00 | 0.00 | 0.129964E+09 | 0.129964E+09 | 4732.49 | 18-OCT-14:40 | 4732.49 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.137456E+11 | 0.134707E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.499083E+10 | 0.490560E+10 | 16457.47 | 16288.68 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.201010E+10 | 0.51 | 2001.37 | 01-JAN-08:62 | 1.01 |
February | 0.163049E+10 | 0.48 | 2001.37 | 01-FEB-08:61 | 1.01 |
March | 0.172060E+10 | 0.46 | 2001.37 | 01-MAR-08:61 | 1.01 |
April | 0.151369E+10 | 0.43 | 2001.37 | 01-APR-07:01 | 1.01 |
May | 0.151520E+10 | 0.42 | 2001.37 | 01-MAY-07:01 | 1.01 |
June | 0.141184E+10 | 0.41 | 953.53 | 16-JUN-08:10 | 0.68 |
July | 0.149178E+10 | 0.42 | 2001.37 | 17-JUL-07:02 | 1.00 |
August | 0.148775E+10 | 0.42 | 2001.37 | 07-AUG-07:02 | 1.00 |
September | 0.144003E+10 | 0.42 | 2001.37 | 04-SEP-07:02 | 1.00 |
October | 0.148937E+10 | 0.42 | 2001.37 | 10-OCT-07:01 | 1.00 |
November | 0.157976E+10 | 0.45 | 2001.37 | 10-NOV-08:61 | 1.01 |
December | 0.186381E+10 | 0.49 | 2001.37 | 01-DEC-08:61 | 1.01 |
Annual Sum or Average | 0.191544E+11 | 0.44 | |||
Minimum of Months | 0.141184E+10 | 0.41 | 953.53 | 0.68 | |
Maximum of Months | 0.201010E+10 | 0.51 | 2001.37 | 1.01 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.157963E+10 | 0.59 | 1158.64 | 02-JAN-15:20 | 1.04 |
February | 0.143133E+10 | 0.58 | 1158.64 | 03-FEB-08:17 | 1.04 |
March | 0.159857E+10 | 0.55 | 1158.64 | 03-MAR-08:10 | 1.04 |
April | 0.159765E+10 | 0.63 | 1158.64 | 03-APR-09:20 | 1.04 |
May | 0.176893E+10 | 0.64 | 1158.64 | 02-MAY-16:40 | 1.04 |
June | 0.184532E+10 | 0.66 | 1158.64 | 01-JUN-13:30 | 1.03 |
July | 0.189931E+10 | 0.65 | 1158.64 | 05-JUL-07:30 | 1.03 |
August | 0.189862E+10 | 0.65 | 1158.64 | 13-AUG-09:50 | 1.03 |
September | 0.180605E+10 | 0.67 | 1158.64 | 11-SEP-07:10 | 1.03 |
October | 0.175414E+10 | 0.67 | 1158.64 | 02-OCT-13:30 | 1.04 |
November | 0.156547E+10 | 0.60 | 1158.64 | 13-NOV-10:20 | 1.04 |
December | 0.156584E+10 | 0.54 | 1158.64 | 01-DEC-11:20 | 1.04 |
Annual Sum or Average | 0.203108E+11 | 0.62 | |||
Minimum of Months | 0.143133E+10 | 0.54 | 1158.64 | 1.03 | |
Maximum of Months | 0.189931E+10 | 0.67 | 1158.64 | 1.04 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.169217E+10 | 0.56 | 1169.27 | 01-JAN-09:08 | 1.04 |
February | 0.153221E+10 | 0.56 | 1169.27 | 01-FEB-07:40 | 1.04 |
March | 0.172584E+10 | 0.57 | 1169.27 | 01-MAR-10:00 | 1.04 |
April | 0.164165E+10 | 0.56 | 1169.27 | 01-APR-06:30 | 1.04 |
May | 0.170900E+10 | 0.57 | 1169.27 | 01-MAY-07:03 | 1.04 |
June | 0.166691E+10 | 0.57 | 1169.27 | 01-JUN-14:10 | 1.03 |
July | 0.168375E+10 | 0.56 | 1169.27 | 01-JUL-09:40 | 1.03 |
August | 0.172584E+10 | 0.57 | 1169.27 | 01-AUG-09:10 | 1.03 |
September | 0.164165E+10 | 0.56 | 1169.27 | 01-SEP-08:40 | 1.03 |
October | 0.169217E+10 | 0.56 | 1169.27 | 02-OCT-12:40 | 1.04 |
November | 0.164165E+10 | 0.56 | 1169.27 | 02-NOV-08:15 | 1.04 |
December | 0.168375E+10 | 0.56 | 1169.27 | 01-DEC-08:40 | 1.04 |
Annual Sum or Average | 0.200366E+11 | 0.56 | |||
Minimum of Months | 0.153221E+10 | 0.56 | 1169.27 | 1.03 | |
Maximum of Months | 0.172584E+10 | 0.57 | 1169.27 | 1.04 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.169952E+10 | 0.56 | 1174.35 | 01-JAN-08:40 | 1.04 |
February | 0.153886E+10 | 0.56 | 1174.35 | 01-FEB-07:55 | 1.04 |
March | 0.173334E+10 | 0.57 | 1174.35 | 01-MAR-07:05 | 1.04 |
April | 0.164878E+10 | 0.56 | 1174.35 | 01-APR-11:20 | 1.04 |
May | 0.171643E+10 | 0.57 | 1174.35 | 01-MAY-11:40 | 1.04 |
June | 0.167415E+10 | 0.57 | 1174.35 | 01-JUN-13:40 | 1.03 |
July | 0.169106E+10 | 0.56 | 1174.35 | 04-JUL-08:00 | 1.03 |
August | 0.173334E+10 | 0.57 | 1174.35 | 02-AUG-06:06 | 1.03 |
September | 0.164878E+10 | 0.56 | 1174.35 | 01-SEP-15:40 | 1.03 |
October | 0.169952E+10 | 0.56 | 1174.35 | 02-OCT-13:10 | 1.04 |
November | 0.164878E+10 | 0.56 | 1174.35 | 02-NOV-08:62 | 1.04 |
December | 0.169106E+10 | 0.56 | 1174.35 | 01-DEC-13:30 | 1.04 |
Annual Sum or Average | 0.201236E+11 | 0.56 | |||
Minimum of Months | 0.153886E+10 | 0.56 | 1174.35 | 1.03 | |
Maximum of Months | 0.173334E+10 | 0.57 | 1174.35 | 1.04 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.167835E+10 | 0.56 | 1159.63 | 01-JAN-09:05 | 1.04 |
February | 0.151958E+10 | 0.56 | 1159.63 | 01-FEB-19:40 | 1.04 |
March | 0.171162E+10 | 0.57 | 1159.63 | 01-MAR-17:40 | 1.04 |
April | 0.162813E+10 | 0.56 | 1159.63 | 01-APR-08:70 | 1.04 |
May | 0.169492E+10 | 0.57 | 1159.63 | 01-MAY-09:20 | 1.04 |
June | 0.165317E+10 | 0.57 | 1159.63 | 01-JUN-15:10 | 1.03 |
July | 0.166987E+10 | 0.56 | 1159.63 | 04-JUL-12:50 | 1.03 |
August | 0.171162E+10 | 0.57 | 1159.63 | 01-AUG-15:40 | 1.03 |
September | 0.162813E+10 | 0.56 | 1159.63 | 03-SEP-07:30 | 1.03 |
October | 0.167822E+10 | 0.56 | 1159.63 | 04-OCT-07:15 | 1.04 |
November | 0.162813E+10 | 0.56 | 1159.63 | 01-NOV-07:50 | 1.04 |
December | 0.166987E+10 | 0.56 | 1159.63 | 01-DEC-16:10 | 1.04 |
Annual Sum or Average | 0.198716E+11 | 0.56 | |||
Minimum of Months | 0.151958E+10 | 0.56 | 1159.63 | 1.03 | |
Maximum of Months | 0.171162E+10 | 0.57 | 1159.63 | 1.04 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.148370E+10 | 0.39 | 1923.85 | 01-JAN-09:01 | 1.01 |
February | 0.119564E+10 | 0.35 | 1923.85 | 01-FEB-08:61 | 1.01 |
March | 0.126977E+10 | 0.35 | 1923.85 | 01-MAR-08:61 | 1.00 |
April | 0.109055E+10 | 0.32 | 1923.85 | 01-APR-07:01 | 1.01 |
May | 0.109833E+10 | 0.32 | 1923.85 | 01-MAY-07:01 | 1.01 |
June | 0.101614E+10 | 0.31 | 895.99 | 16-JUN-08:18 | 0.67 |
July | 0.105096E+10 | 0.30 | 1923.85 | 16-JUL-08:62 | 0.99 |
August | 0.107659E+10 | 0.31 | 1923.85 | 06-AUG-08:62 | 1.00 |
September | 0.102186E+10 | 0.31 | 1923.85 | 04-SEP-08:62 | 1.00 |
October | 0.106849E+10 | 0.31 | 1923.85 | 08-OCT-08:61 | 1.00 |
November | 0.115697E+10 | 0.33 | 1923.85 | 10-NOV-08:61 | 1.01 |
December | 0.135989E+10 | 0.36 | 1923.85 | 01-DEC-08:61 | 1.01 |
Annual Sum or Average | 0.138889E+11 | 0.33 | |||
Minimum of Months | 0.101614E+10 | 0.30 | 895.99 | 0.67 | |
Maximum of Months | 0.148370E+10 | 0.39 | 1923.85 | 1.01 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.136925E+10 | 0.53 | 1024.31 | 09-JAN-21:00 | 1.05 |
February | 0.123900E+10 | 0.52 | 1024.31 | 10-FEB-15:10 | 1.04 |
March | 0.139756E+10 | 0.53 | 1024.31 | 01-MAR-14:20 | 1.04 |
April | 0.132750E+10 | 0.52 | 1024.31 | 03-APR-09:20 | 1.04 |
May | 0.138281E+10 | 0.52 | 1024.31 | 02-MAY-16:30 | 1.04 |
June | 0.134963E+10 | 0.53 | 1024.31 | 03-JUN-16:40 | 1.03 |
July | 0.136069E+10 | 0.51 | 1024.31 | 05-JUL-13:00 | 1.03 |
August | 0.139756E+10 | 0.53 | 1024.31 | 01-AUG-19:20 | 1.03 |
September | 0.132750E+10 | 0.52 | 1024.31 | 01-SEP-19:03 | 1.04 |
October | 0.136806E+10 | 0.52 | 1024.31 | 04-OCT-08:30 | 1.04 |
November | 0.132750E+10 | 0.52 | 1024.31 | 16-NOV-20:30 | 1.04 |
December | 0.136087E+10 | 0.52 | 1024.31 | 06-DEC-19:00 | 1.04 |
Annual Sum or Average | 0.162079E+11 | 0.52 | |||
Minimum of Months | 0.123900E+10 | 0.51 | 1024.31 | 1.03 | |
Maximum of Months | 0.139756E+10 | 0.53 | 1024.31 | 1.05 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.135520E+10 | 0.53 | 1013.63 | 03-JAN-11:00 | 1.04 |
February | 0.122609E+10 | 0.52 | 1013.63 | 02-FEB-08:06 | 1.04 |
March | 0.138300E+10 | 0.53 | 1013.63 | 03-MAR-17:10 | 1.04 |
April | 0.131367E+10 | 0.52 | 1013.63 | 01-APR-09:10 | 1.04 |
May | 0.136840E+10 | 0.52 | 1013.63 | 01-MAY-07:09 | 1.04 |
June | 0.133556E+10 | 0.53 | 1013.63 | 07-JUN-19:20 | 1.04 |
July | 0.134651E+10 | 0.51 | 1013.63 | 04-JUL-13:30 | 1.03 |
August | 0.138300E+10 | 0.53 | 1013.63 | 02-AUG-19:50 | 1.04 |
September | 0.131367E+10 | 0.52 | 1013.63 | 11-SEP-07:40 | 1.03 |
October | 0.135381E+10 | 0.52 | 1013.63 | 03-OCT-08:17 | 1.04 |
November | 0.131367E+10 | 0.52 | 1013.63 | 05-NOV-09:50 | 1.04 |
December | 0.134670E+10 | 0.52 | 1013.63 | 01-DEC-19:50 | 1.04 |
Annual Sum or Average | 0.160393E+11 | 0.52 | |||
Minimum of Months | 0.122609E+10 | 0.51 | 1013.63 | 1.03 | |
Maximum of Months | 0.138300E+10 | 0.53 | 1013.63 | 1.04 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.133836E+10 | 0.53 | 1000.28 | 01-JAN-10:30 | 1.04 |
February | 0.121007E+10 | 0.52 | 1000.28 | 01-FEB-08:18 | 1.04 |
March | 0.136493E+10 | 0.53 | 1000.28 | 09-MAR-19:40 | 1.04 |
April | 0.129636E+10 | 0.52 | 1000.28 | 21-APR-14:00 | 1.04 |
May | 0.135037E+10 | 0.52 | 1000.28 | 01-MAY-07:08 | 1.04 |
June | 0.131797E+10 | 0.53 | 1000.28 | 13-JUN-09:30 | 1.03 |
July | 0.132877E+10 | 0.51 | 1000.28 | 01-JUL-07:50 | 1.03 |
August | 0.136478E+10 | 0.53 | 1000.28 | 01-AUG-07:08 | 1.04 |
September | 0.129636E+10 | 0.52 | 1000.28 | 01-SEP-07:50 | 1.03 |
October | 0.133597E+10 | 0.52 | 1000.28 | 05-OCT-11:30 | 1.04 |
November | 0.129636E+10 | 0.52 | 1000.28 | 10-NOV-16:20 | 1.04 |
December | 0.132907E+10 | 0.52 | 1000.28 | 10-DEC-14:20 | 1.04 |
Annual Sum or Average | 0.158294E+11 | 0.52 | |||
Minimum of Months | 0.121007E+10 | 0.51 | 1000.28 | 1.03 | |
Maximum of Months | 0.136493E+10 | 0.53 | 1000.28 | 1.04 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.151067E+10 | 0.61 | 1113.50 | 04-JAN-13:50 | 1.04 |
February | 0.135186E+10 | 0.55 | 1113.50 | 03-FEB-17:30 | 1.04 |
March | 0.152397E+10 | 0.55 | 1113.50 | 02-MAR-15:10 | 1.04 |
April | 0.144309E+10 | 0.52 | 1113.50 | 03-APR-16:00 | 1.04 |
May | 0.150322E+10 | 0.52 | 1113.50 | 06-MAY-11:25 | 1.04 |
June | 0.146715E+10 | 0.53 | 1113.50 | 02-JUN-13:30 | 1.04 |
July | 0.147917E+10 | 0.51 | 1113.50 | 03-JUL-10:40 | 1.03 |
August | 0.151926E+10 | 0.53 | 1113.50 | 01-AUG-19:10 | 1.03 |
September | 0.144309E+10 | 0.52 | 1113.50 | 03-SEP-09:40 | 1.03 |
October | 0.148719E+10 | 0.52 | 1113.50 | 08-OCT-10:10 | 1.04 |
November | 0.144404E+10 | 0.53 | 1113.50 | 03-NOV-09:40 | 1.04 |
December | 0.148361E+10 | 0.54 | 1113.50 | 02-DEC-08:09 | 1.04 |
Annual Sum or Average | 0.176563E+11 | 0.53 | |||
Minimum of Months | 0.135186E+10 | 0.51 | 1113.50 | 1.03 | |
Maximum of Months | 0.152397E+10 | 0.61 | 1113.50 | 1.04 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.99 | 0.33 |
February | 0.94 | 0.73 |
March | 1.17 | 0.50 |
April | 0.17 | 1.50 |
May | 0.08 | 1.50 |
June | 0.04 | 1.50 |
July | 0.50 | 0.50 |
August | 0.42 | 0.90 |
September | 0.56 | 1.50 |
October | 0.22 | 1.12 |
November | 0.42 | 0.30 |
December | 0.83 | 0.65 |
Annual Sum or Average | 7.34 | 0.64 |
Minimum of Months | 0.04 | 0.30 |
Maximum of Months | 1.99 | 1.50 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.66 | 3.13 |
February | 0.58 | 6.64 |
March | 0.99 | 4.69 |
April | 1.22 | 5.49 |
May | 3.88 | 4.54 |
June | 4.22 | 3.70 |
July | 4.54 | 2.34 |
August | 7.72 | 2.71 |
September | 5.07 | 3.58 |
October | 1.25 | 3.87 |
November | 1.31 | 5.35 |
December | 0.28 | 4.72 |
Annual Sum or Average | 31.71 | 3.57 |
Minimum of Months | 0.28 | 2.34 |
Maximum of Months | 7.72 | 6.64 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.34 | 0.00 |
February | 0.17 | 0.00 |
March | 0.07 | 0.00 |
April | 0.53 | 0.75 |
May | 1.26 | 0.65 |
June | 1.59 | 0.75 |
July | 3.02 | 0.75 |
August | 2.60 | 0.71 |
September | 1.79 | 0.75 |
October | 1.35 | 0.58 |
November | 0.33 | 0.75 |
December | 0.17 | 0.00 |
Annual Sum or Average | 13.20 | 0.67 |
Minimum of Months | 0.07 | 0.00 |
Maximum of Months | 3.02 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.49 | 0.00 |
February | 0.17 | 0.00 |
March | 0.07 | 0.00 |
April | 0.53 | 0.75 |
May | 1.10 | 0.69 |
June | 1.59 | 0.75 |
July | 3.02 | 0.75 |
August | 2.52 | 0.73 |
September | 1.79 | 0.75 |
October | 1.35 | 0.58 |
November | 0.28 | 0.52 |
December | 0.21 | 0.00 |
Annual Sum or Average | 13.10 | 0.67 |
Minimum of Months | 0.07 | 0.00 |
Maximum of Months | 3.02 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.61 | 0.00 |
February | 0.17 | 0.00 |
March | 0.07 | 0.00 |
April | 0.36 | 0.75 |
May | 0.89 | 0.68 |
June | 1.51 | 0.75 |
July | 2.90 | 0.75 |
August | 2.35 | 0.71 |
September | 1.71 | 0.75 |
October | 0.88 | 0.61 |
November | 0.11 | 0.75 |
December | 0.21 | 0.00 |
Annual Sum or Average | 11.75 | 0.66 |
Minimum of Months | 0.07 | 0.00 |
Maximum of Months | 2.90 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.49 | 0.00 |
February | 0.40 | 0.00 |
March | 0.25 | 0.00 |
April | 0.00 | 0.00 |
May | 0.08 | 0.00 |
June | 0.38 | 3.30 |
July | 0.96 | 3.30 |
August | 0.69 | 2.64 |
September | 0.91 | 3.00 |
October | 0.14 | 0.00 |
November | 0.11 | 0.00 |
December | 0.49 | 0.00 |
Annual Sum or Average | 5.92 | 1.52 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.49 | 3.30 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.18 | 0.00 |
February | 0.27 | 0.00 |
March | 0.25 | 0.00 |
April | 0.00 | 0.00 |
May | 0.14 | 0.66 |
June | 0.55 | 1.65 |
July | 1.10 | 1.65 |
August | 0.83 | 1.10 |
September | 0.91 | 1.65 |
October | 0.08 | 0.00 |
November | 0.11 | 0.00 |
December | 0.49 | 0.00 |
Annual Sum or Average | 5.92 | 0.88 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.18 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.34 | 0.00 |
February | 0.27 | 0.00 |
March | 0.25 | 0.00 |
April | 0.00 | 0.00 |
May | 0.14 | 0.66 |
June | 0.46 | 1.65 |
July | 1.10 | 1.65 |
August | 0.83 | 1.10 |
September | 0.91 | 1.65 |
October | 0.14 | 0.00 |
November | 0.11 | 0.00 |
December | 0.57 | 0.00 |
Annual Sum or Average | 6.14 | 0.83 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.34 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.76 | 0.00 |
February | 0.57 | 0.00 |
March | 0.34 | 0.00 |
April | 0.00 | 0.00 |
May | 0.14 | 0.66 |
June | 0.46 | 1.65 |
July | 1.10 | 1.65 |
August | 0.75 | 1.22 |
September | 0.91 | 1.65 |
October | 0.08 | 0.00 |
November | 0.22 | 0.00 |
December | 0.67 | 0.00 |
Annual Sum or Average | 7.00 | 0.73 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.76 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 3.60 | 0.00 |
February | 1.83 | 0.00 |
March | 0.95 | 0.00 |
April | 0.39 | 0.00 |
May | 0.25 | 0.00 |
June | 0.42 | 1.32 |
July | 1.10 | 1.65 |
August | 0.75 | 1.22 |
September | 0.91 | 1.65 |
October | 0.08 | 0.00 |
November | 0.75 | 0.00 |
December | 2.19 | 0.00 |
Annual Sum or Average | 13.22 | 0.36 |
Minimum of Months | 0.08 | 0.00 |
Maximum of Months | 3.60 | 1.65 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.201010E+10 | 0.338230E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.163049E+10 | 0.192127E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.172060E+10 | 0.161184E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.152381E+10 | 0.636535E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.189320E+10 | 0.381802E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.303206E+10 | 0.119851E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.484996E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.422144E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.290599E+10 | 0.583764E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.163997E+10 | 0.224826E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.157976E+10 | 0.107053E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.186381E+10 | 0.246742E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.288712E+11 | 0.117669E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.152381E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.484996E+10 | 0.338230E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.157963E+10 | 0.111100E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.143173E+10 | 0.564066E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.159857E+10 | 0.370900E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.161630E+10 | 0.102187E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.203980E+10 | 0.629626E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.280643E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.374676E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.342545E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.261642E+10 | 11210116.68 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.185162E+10 | 0.261172E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.156695E+10 | 0.247604E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.156584E+10 | 0.729506E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.258455E+11 | 0.321546E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.143173E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.374676E+10 | 0.111100E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.169217E+10 | 0.125271E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.153221E+10 | 0.665412E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.172584E+10 | 0.472909E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.165281E+10 | 0.140938E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.188121E+10 | 0.906586E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.238163E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.308791E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.288697E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.221978E+10 | 32851308.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.176976E+10 | 0.464794E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.164166E+10 | 0.318433E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.168375E+10 | 0.862185E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.241557E+11 | 0.385301E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.153221E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.308791E+10 | 0.125271E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.169952E+10 | 0.128673E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.153886E+10 | 0.689692E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.173334E+10 | 0.500841E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.165849E+10 | 0.155912E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.188359E+10 | 0.100436E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.238526E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.309956E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.289647E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.222557E+10 | 47837672.10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.177221E+10 | 0.536771E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.164878E+10 | 0.340530E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.169106E+10 | 0.893831E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.242327E+11 | 0.402643E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.153886E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.309956E+10 | 0.128673E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.167835E+10 | 0.134223E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.151958E+10 | 0.732304E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.171162E+10 | 0.549301E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.163516E+10 | 0.186591E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.184746E+10 | 0.118072E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.233544E+10 | 1621058.95 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.303997E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.283925E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.218349E+10 | 88514315.18 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.174176E+10 | 0.664630E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.162813E+10 | 0.376839E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.166987E+10 | 0.945506E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.238301E+11 | 0.432631E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.151958E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.303997E+10 | 0.134223E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.148370E+10 | 0.281468E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.119564E+10 | 0.163896E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.126977E+10 | 0.136050E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.109461E+10 | 0.576998E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.132441E+10 | 0.367984E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.221274E+10 | 0.127130E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.352378E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.311851E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.202328E+10 | 0.678732E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.116205E+10 | 0.251835E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.115697E+10 | 0.988131E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.135989E+10 | 0.208886E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.209253E+11 | 0.101685E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.109461E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.352378E+10 | 0.281468E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.136925E+10 | 0.139361E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.123917E+10 | 0.787256E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.139756E+10 | 0.627061E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.133895E+10 | 0.244131E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.154736E+10 | 0.154862E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.207698E+10 | 31935113.61 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.268913E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.256434E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.195131E+10 | 0.225496E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.147141E+10 | 0.971417E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.132750E+10 | 0.445274E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.136087E+10 | 0.100944E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.203338E+11 | 0.478452E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.123917E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.268913E+10 | 0.139361E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.135520E+10 | 0.140600E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.122615E+10 | 0.798854E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.138300E+10 | 0.641940E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.132388E+10 | 0.255169E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.152508E+10 | 0.161567E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.204309E+10 | 36762274.93 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.265429E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.253013E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.192544E+10 | 0.243219E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.145256E+10 | 0.101692E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.131367E+10 | 0.456179E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.134670E+10 | 0.102247E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.200792E+11 | 0.487187E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.122615E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.265429E+10 | 0.140600E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.133836E+10 | 0.145935E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.121007E+10 | 0.845321E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.136493E+10 | 0.696645E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.130340E+10 | 0.295440E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.148574E+10 | 0.186354E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.197305E+10 | 58855936.06 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.259052E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.246720E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.187840E+10 | 0.307613E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.142095E+10 | 0.117513E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.129636E+10 | 0.493405E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.132907E+10 | 0.107256E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.196581E+11 | 0.520323E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.121007E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.259052E+10 | 0.145935E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.151067E+10 | 0.175155E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.135186E+10 | 0.104104E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.152397E+10 | 0.904162E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.144330E+10 | 0.425667E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.158993E+10 | 0.264760E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.199004E+10 | 0.133286E+09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.263841E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.246263E+10 | 12680396.77 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.188050E+10 | 0.496421E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.151721E+10 | 0.160396E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.144404E+10 | 0.607817E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.148361E+10 | 0.127224E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.208362E+11 | 0.649186E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.135186E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.263841E+10 | 0.175155E+11 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.201010E+10 | 0.00 | 0.270584E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.163049E+10 | 517.58 | 0.153701E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.172060E+10 | 0.00 | 0.128947E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.151369E+10 | 36535100.73 | 0.509228E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.151520E+10 | 0.144806E+10 | 0.305441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.141184E+10 | 0.634181E+10 | 95880957.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.149178E+10 | 0.129984E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.148775E+10 | 0.105700E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.144003E+10 | 0.578338E+10 | 0.467012E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148937E+10 | 0.584933E+09 | 0.179861E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.157976E+10 | 0.00 | 0.856422E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.186381E+10 | 0.00 | 0.197394E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.191544E+11 | 0.377632E+11 | 0.941351E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.141184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.201010E+10 | 0.129984E+11 | 0.270584E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.157963E+10 | 0.00 | 0.888797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.143133E+10 | 1475374.14 | 0.451253E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.159857E+10 | 0.00 | 0.296720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.159765E+10 | 83060944.73 | 0.817500E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.176893E+10 | 0.125384E+10 | 0.503701E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.184532E+10 | 0.441773E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.189931E+10 | 0.828962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.189862E+10 | 0.686328E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.180605E+10 | 0.370729E+10 | 8968093.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.175414E+10 | 0.444489E+09 | 0.208938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.156547E+10 | 6215933.25 | 0.198083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.156584E+10 | 0.00 | 0.583605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203108E+11 | 0.250670E+11 | 0.257237E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.143133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.189931E+10 | 0.828962E+10 | 0.888797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.169217E+10 | 0.00 | 0.100217E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153221E+10 | 1661.22 | 0.532330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.172584E+10 | 0.00 | 0.378327E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.164165E+10 | 47467491.99 | 0.112750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.170900E+10 | 0.767575E+09 | 0.725269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.166691E+10 | 0.321566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.168375E+10 | 0.621007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.172584E+10 | 0.513884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.164165E+10 | 0.261045E+10 | 26281046.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.169217E+10 | 0.348474E+09 | 0.371836E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.164165E+10 | 15855.87 | 0.254746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168375E+10 | 0.00 | 0.689748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.200366E+11 | 0.183385E+11 | 0.308241E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.153221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.172584E+10 | 0.621007E+10 | 0.100217E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.169952E+10 | 0.00 | 0.102938E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153886E+10 | 909.54 | 0.551753E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.173334E+10 | 0.00 | 0.400673E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.164878E+10 | 41079181.07 | 0.124730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.171643E+10 | 0.742872E+09 | 0.803485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.167415E+10 | 0.319541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.169106E+10 | 0.622822E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.173334E+10 | 0.514620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.164878E+10 | 0.260312E+10 | 38270137.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.169952E+10 | 0.325677E+09 | 0.429416E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.164878E+10 | 1256.77 | 0.272424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.169106E+10 | 0.00 | 0.715065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.201236E+11 | 0.182826E+11 | 0.322114E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.153886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.173334E+10 | 0.622822E+10 | 0.102938E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.167835E+10 | 0.00 | 0.107378E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.151958E+10 | 575.71 | 0.585843E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.171162E+10 | 0.00 | 0.439441E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.162813E+10 | 29531651.48 | 0.149273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.169492E+10 | 0.673444E+09 | 0.944576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.165317E+10 | 0.305442E+10 | 1296847.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.166987E+10 | 0.604363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.171162E+10 | 0.497750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.162813E+10 | 0.250109E+10 | 70811452.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.167822E+10 | 0.283255E+09 | 0.531704E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.162813E+10 | 5099.40 | 0.301471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.166987E+10 | 0.00 | 0.756405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.198716E+11 | 0.175629E+11 | 0.346105E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.151958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.171162E+10 | 0.604363E+10 | 0.107378E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.148370E+10 | 0.00 | 0.225175E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119564E+10 | 0.00 | 0.131117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.126977E+10 | 0.00 | 0.108840E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.109055E+10 | 14472416.40 | 0.461598E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.109833E+10 | 0.850632E+09 | 0.294387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.101614E+10 | 0.461905E+10 | 0.101704E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.105096E+10 | 0.946307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.107659E+10 | 0.782306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.102186E+10 | 0.393415E+10 | 0.542986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.106849E+10 | 0.357721E+09 | 0.201468E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.115697E+10 | 0.00 | 0.790505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.135989E+10 | 0.00 | 0.167109E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.138889E+11 | 0.270622E+11 | 0.813483E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.101614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.148370E+10 | 0.946307E+10 | 0.225175E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.136925E+10 | 0.00 | 0.111489E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.123900E+10 | 676217.84 | 0.629805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.139756E+10 | 0.00 | 0.501649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.132750E+10 | 48183032.35 | 0.195305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.138281E+10 | 0.716223E+09 | 0.123890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.134963E+10 | 0.322498E+10 | 25548090.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.136069E+10 | 0.582918E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.139756E+10 | 0.513629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.132750E+10 | 0.280434E+10 | 0.180397E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.136806E+10 | 0.457255E+09 | 0.777133E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.132750E+10 | 0.00 | 0.356219E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.136087E+10 | 0.00 | 0.807554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.162079E+11 | 0.182171E+11 | 0.382762E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.123900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.139756E+10 | 0.582918E+10 | 0.111489E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.135520E+10 | 0.00 | 0.112480E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122609E+10 | 245109.95 | 0.639083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.138300E+10 | 0.00 | 0.513552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.131367E+10 | 42852589.04 | 0.204135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.136840E+10 | 0.680621E+09 | 0.129254E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.133556E+10 | 0.313344E+10 | 29409819.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.134651E+10 | 0.573374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.138300E+10 | 0.504555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.131367E+10 | 0.274846E+10 | 0.194576E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.135381E+10 | 0.436351E+09 | 0.813538E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.131367E+10 | 0.00 | 0.364943E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.134670E+10 | 0.00 | 0.817973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.160393E+11 | 0.178213E+11 | 0.389749E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.122609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.138300E+10 | 0.573374E+10 | 0.112480E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.133836E+10 | 0.00 | 0.116748E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.121007E+10 | 0.00 | 0.676257E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136493E+10 | 0.00 | 0.557316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129636E+10 | 29290976.72 | 0.236352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.135037E+10 | 0.583872E+09 | 0.149083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.131797E+10 | 0.288833E+10 | 47084748.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.132877E+10 | 0.551650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.136478E+10 | 0.483572E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.129636E+10 | 0.260891E+10 | 0.246090E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133597E+10 | 0.373610E+09 | 0.940108E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.129636E+10 | 0.00 | 0.394724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132907E+10 | 0.00 | 0.858047E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.158294E+11 | 0.168362E+11 | 0.416259E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.121007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.136493E+10 | 0.551650E+10 | 0.116748E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.151067E+10 | 0.00 | 0.140124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.135186E+10 | 0.00 | 0.832833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.152397E+10 | 0.00 | 0.723330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.144309E+10 | 802547.46 | 0.340533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150322E+10 | 0.364570E+09 | 0.211808E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.146715E+10 | 0.225718E+10 | 0.106629E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147917E+10 | 0.499083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151926E+10 | 0.406937E+10 | 10144317.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.144309E+10 | 0.193289E+10 | 0.397137E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148719E+10 | 0.129964E+09 | 0.128317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144404E+10 | 0.00 | 0.486253E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.148361E+10 | 0.00 | 0.101779E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.176563E+11 | 0.137456E+11 | 0.519349E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.135186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.152397E+10 | 0.499083E+10 | 0.140124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.201010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338230E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.163049E+10 | 0.00 | 0.00 | 0.00 | 146.30 | 0.00 | 0.192127E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.172060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161184E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.151369E+10 | 0.00 | 0.00 | 0.00 | 10114761.85 | 0.00 | 0.636535E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.151520E+10 | 0.00 | 0.00 | 0.00 | 0.378004E+09 | 0.00 | 0.381802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.141184E+10 | 0.00 | 0.00 | 0.00 | 0.162021E+10 | 0.00 | 0.119851E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.149178E+10 | 0.00 | 0.00 | 0.00 | 0.335819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.148775E+10 | 0.00 | 0.00 | 0.00 | 0.273369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.144003E+10 | 0.00 | 0.00 | 0.00 | 0.146595E+10 | 0.00 | 0.583764E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148937E+10 | 0.00 | 0.00 | 0.00 | 0.150603E+09 | 0.00 | 0.224826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.157976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107053E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.186381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.246742E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.191544E+11 | 0.00 | 0.00 | 0.00 | 0.971677E+10 | 0.00 | 0.117669E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.141184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.201010E+10 | 0.00 | 0.00 | 0.00 | 0.335819E+10 | 0.00 | 0.338230E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.157963E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111100E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.143133E+10 | 0.00 | 0.00 | 0.00 | 406776.77 | 0.00 | 0.564066E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.159857E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.159765E+10 | 0.00 | 0.00 | 0.00 | 18647870.14 | 0.00 | 0.102187E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.176893E+10 | 0.00 | 0.00 | 0.00 | 0.270870E+09 | 0.00 | 0.629626E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.184532E+10 | 0.00 | 0.00 | 0.00 | 0.961115E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.189931E+10 | 0.00 | 0.00 | 0.00 | 0.184745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.189862E+10 | 0.00 | 0.00 | 0.00 | 0.152683E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.180605E+10 | 0.00 | 0.00 | 0.00 | 0.810363E+09 | 0.00 | 11210116.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.175414E+10 | 0.00 | 0.00 | 0.00 | 97484675.99 | 0.00 | 0.261172E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.156547E+10 | 0.00 | 0.00 | 0.00 | 1471936.13 | 0.00 | 0.247604E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.156584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.729506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203108E+11 | 0.00 | 0.00 | 0.00 | 0.553464E+10 | 0.00 | 0.321546E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.143133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.189931E+10 | 0.00 | 0.00 | 0.00 | 0.184745E+10 | 0.00 | 0.111100E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.169217E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125271E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153221E+10 | 0.00 | 0.00 | 0.00 | 409.42 | 0.00 | 0.665412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.172584E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.472909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.164165E+10 | 0.00 | 0.00 | 0.00 | 11158861.04 | 0.00 | 0.140938E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.170900E+10 | 0.00 | 0.00 | 0.00 | 0.172204E+09 | 0.00 | 0.906586E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.166691E+10 | 0.00 | 0.00 | 0.00 | 0.714714E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.168375E+10 | 0.00 | 0.00 | 0.00 | 0.140416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.172584E+10 | 0.00 | 0.00 | 0.00 | 0.116113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.164165E+10 | 0.00 | 0.00 | 0.00 | 0.578124E+09 | 0.00 | 32851308.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.169217E+10 | 0.00 | 0.00 | 0.00 | 77594571.40 | 0.00 | 0.464794E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.164165E+10 | 0.00 | 0.00 | 0.00 | 3904.91 | 0.00 | 0.318433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.168375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.862185E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.200366E+11 | 0.00 | 0.00 | 0.00 | 0.411909E+10 | 0.00 | 0.385301E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.153221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.172584E+10 | 0.00 | 0.00 | 0.00 | 0.140416E+10 | 0.00 | 0.125271E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.169952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128673E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153886E+10 | 0.00 | 0.00 | 0.00 | 224.17 | 0.00 | 0.689692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.173334E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.500841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.164878E+10 | 0.00 | 0.00 | 0.00 | 9701699.62 | 0.00 | 0.155912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.171643E+10 | 0.00 | 0.00 | 0.00 | 0.167160E+09 | 0.00 | 0.100436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.167415E+10 | 0.00 | 0.00 | 0.00 | 0.711109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.169106E+10 | 0.00 | 0.00 | 0.00 | 0.140850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.173334E+10 | 0.00 | 0.00 | 0.00 | 0.116313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.164878E+10 | 0.00 | 0.00 | 0.00 | 0.576784E+09 | 0.00 | 47837672.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.169952E+10 | 0.00 | 0.00 | 0.00 | 72694086.30 | 0.00 | 0.536771E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.164878E+10 | 0.00 | 0.00 | 0.00 | 309.74 | 0.00 | 0.340530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.169106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.893831E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.201236E+11 | 0.00 | 0.00 | 0.00 | 0.410908E+10 | 0.00 | 0.402643E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.153886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.173334E+10 | 0.00 | 0.00 | 0.00 | 0.140850E+10 | 0.00 | 0.128673E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.167835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134223E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.151958E+10 | 0.00 | 0.00 | 0.00 | 141.89 | 0.00 | 0.732304E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.171162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.549301E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.162813E+10 | 0.00 | 0.00 | 0.00 | 7037922.15 | 0.00 | 0.186591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.169492E+10 | 0.00 | 0.00 | 0.00 | 0.152536E+09 | 0.00 | 0.118072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.165317E+10 | 0.00 | 0.00 | 0.00 | 0.682272E+09 | 0.00 | 1621058.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.166987E+10 | 0.00 | 0.00 | 0.00 | 0.137010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.171162E+10 | 0.00 | 0.00 | 0.00 | 0.112763E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.162813E+10 | 0.00 | 0.00 | 0.00 | 0.555364E+09 | 0.00 | 88514315.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.167822E+10 | 0.00 | 0.00 | 0.00 | 63536327.12 | 0.00 | 0.664630E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.162813E+10 | 0.00 | 0.00 | 0.00 | 1256.54 | 0.00 | 0.376839E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.166987E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.945506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.198716E+11 | 0.00 | 0.00 | 0.00 | 0.395847E+10 | 0.00 | 0.432631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.151958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.171162E+10 | 0.00 | 0.00 | 0.00 | 0.137010E+10 | 0.00 | 0.134223E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.148370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281468E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119564E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163896E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.126977E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136050E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.109055E+10 | 0.00 | 0.00 | 0.00 | 4061066.72 | 0.00 | 0.576998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.109833E+10 | 0.00 | 0.00 | 0.00 | 0.226073E+09 | 0.00 | 0.367984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.101614E+10 | 0.00 | 0.00 | 0.00 | 0.119660E+10 | 0.00 | 0.127130E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.105096E+10 | 0.00 | 0.00 | 0.00 | 0.247283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.107659E+10 | 0.00 | 0.00 | 0.00 | 0.204192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.102186E+10 | 0.00 | 0.00 | 0.00 | 0.100141E+10 | 0.00 | 0.678732E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.106849E+10 | 0.00 | 0.00 | 0.00 | 93562584.30 | 0.00 | 0.251835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.115697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.988131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.135989E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208886E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.138889E+11 | 0.00 | 0.00 | 0.00 | 0.703646E+10 | 0.00 | 0.101685E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.101614E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.148370E+10 | 0.00 | 0.00 | 0.00 | 0.247283E+10 | 0.00 | 0.281468E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.136925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139361E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.123900E+10 | 0.00 | 0.00 | 0.00 | 165102.50 | 0.00 | 0.787256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.139756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.627061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.132750E+10 | 0.00 | 0.00 | 0.00 | 11454500.11 | 0.00 | 0.244131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.138281E+10 | 0.00 | 0.00 | 0.00 | 0.164551E+09 | 0.00 | 0.154862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.134963E+10 | 0.00 | 0.00 | 0.00 | 0.727357E+09 | 0.00 | 31935113.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.136069E+10 | 0.00 | 0.00 | 0.00 | 0.132845E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.139756E+10 | 0.00 | 0.00 | 0.00 | 0.116678E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.132750E+10 | 0.00 | 0.00 | 0.00 | 0.623808E+09 | 0.00 | 0.225496E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.136806E+10 | 0.00 | 0.00 | 0.00 | 0.103348E+09 | 0.00 | 0.971417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.132750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.445274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.136087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100944E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.162079E+11 | 0.00 | 0.00 | 0.00 | 0.412591E+10 | 0.00 | 0.478452E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.123900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.139756E+10 | 0.00 | 0.00 | 0.00 | 0.132845E+10 | 0.00 | 0.139361E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.135520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140600E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.122609E+10 | 0.00 | 0.00 | 0.00 | 60150.20 | 0.00 | 0.798854E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.138300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.641940E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.131367E+10 | 0.00 | 0.00 | 0.00 | 10209412.60 | 0.00 | 0.255169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.136840E+10 | 0.00 | 0.00 | 0.00 | 0.156674E+09 | 0.00 | 0.161567E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.133556E+10 | 0.00 | 0.00 | 0.00 | 0.707524E+09 | 0.00 | 36762274.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.134651E+10 | 0.00 | 0.00 | 0.00 | 0.130778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.138300E+10 | 0.00 | 0.00 | 0.00 | 0.114713E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.131367E+10 | 0.00 | 0.00 | 0.00 | 0.611769E+09 | 0.00 | 0.243219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.135381E+10 | 0.00 | 0.00 | 0.00 | 98752779.14 | 0.00 | 0.101692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.131367E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.456179E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.134670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102247E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.160393E+11 | 0.00 | 0.00 | 0.00 | 0.403990E+10 | 0.00 | 0.487187E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.122609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.138300E+10 | 0.00 | 0.00 | 0.00 | 0.130778E+10 | 0.00 | 0.140600E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.133836E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.121007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.845321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.696645E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129636E+10 | 0.00 | 0.00 | 0.00 | 7038557.17 | 0.00 | 0.295440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.135037E+10 | 0.00 | 0.00 | 0.00 | 0.135368E+09 | 0.00 | 0.186354E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.131797E+10 | 0.00 | 0.00 | 0.00 | 0.655088E+09 | 0.00 | 58855936.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.132877E+10 | 0.00 | 0.00 | 0.00 | 0.126176E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.136478E+10 | 0.00 | 0.00 | 0.00 | 0.110242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.129636E+10 | 0.00 | 0.00 | 0.00 | 0.582038E+09 | 0.00 | 0.307613E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133597E+10 | 0.00 | 0.00 | 0.00 | 84979821.43 | 0.00 | 0.117513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.129636E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.493405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132907E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107256E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.158294E+11 | 0.00 | 0.00 | 0.00 | 0.382869E+10 | 0.00 | 0.520323E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.121007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.136493E+10 | 0.00 | 0.00 | 0.00 | 0.126176E+10 | 0.00 | 0.145935E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.151067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175155E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.135186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104104E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.152397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.904162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.144309E+10 | 0.00 | 0.00 | 0.00 | 202381.82 | 0.00 | 0.425667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150322E+10 | 0.00 | 0.00 | 0.00 | 86707851.38 | 0.00 | 0.264760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.146715E+10 | 0.00 | 0.00 | 0.00 | 0.522895E+09 | 0.00 | 0.133286E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147917E+10 | 0.00 | 0.00 | 0.00 | 0.115924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151926E+10 | 0.00 | 0.00 | 0.00 | 0.943369E+09 | 0.00 | 12680396.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.144309E+10 | 0.00 | 0.00 | 0.00 | 0.437410E+09 | 0.00 | 0.496421E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148719E+10 | 0.00 | 0.00 | 0.00 | 30026191.97 | 0.00 | 0.160396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.607817E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.148361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127224E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.176563E+11 | 0.00 | 0.00 | 0.00 | 0.317985E+10 | 0.00 | 0.649186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.135186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.152397E+10 | 0.00 | 0.00 | 0.00 | 0.115924E+10 | 0.00 | 0.175155E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.446639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175677E+11 | 0.00 | 0.00 | 0.52 |
February | 0.582602E+10 | 0.00 | 0.00 | 20676.63 | 0.00 | 0.940737E+10 | 24487100.38 | 0.00 | 0.52 |
March | 0.805033E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.660973E+10 | 0.00 | 0.00 | 0.53 |
April | 0.713517E+10 | 0.00 | 0.00 | 489746.18 | 0.00 | 0.228524E+10 | 0.413605E+09 | 0.00 | 0.55 |
May | 0.540059E+10 | 44992687.78 | 0.00 | 7199167.74 | 4312862.00 | 0.128734E+10 | 0.179927E+10 | 0.00 | 0.64 |
June | 0.145499E+10 | 0.569771E+09 | 0.00 | 16490125.26 | 0.00 | 1639350.96 | 0.377872E+10 | 0.00 | 0.77 |
July | 0.180506E+09 | 0.146877E+10 | 0.00 | 21010847.61 | 0.00 | 0.00 | 0.288488E+10 | 0.00 | 0.77 |
August | 0.511745E+09 | 0.103655E+10 | 0.00 | 22151250.85 | 0.00 | 0.00 | 0.394684E+10 | 0.00 | 0.82 |
September | 0.313615E+10 | 0.535657E+09 | 0.00 | 13291870.22 | 0.00 | 10510832.19 | 0.361269E+10 | 0.00 | 0.74 |
October | 0.726112E+10 | 3826062.86 | 0.00 | 3551189.94 | 0.00 | 0.462221E+09 | 0.231140E+10 | 0.00 | 0.60 |
November | 0.876732E+10 | 0.00 | 0.00 | 20914.13 | 0.00 | 0.393837E+10 | 59942401.69 | 0.00 | 0.52 |
December | 0.739908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112131E+11 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.595894E+11 | 0.365957E+10 | 0.00 | 84225788.56 | 4312862.00 | 0.527832E+11 | 0.188318E+11 | 0.00 | 0.63 |
Minimum of Months | 0.180506E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
Maximum of Months | 0.876732E+10 | 0.146877E+10 | 0.00 | 22151250.85 | 4312862.00 | 0.175677E+11 | 0.394684E+10 | 0.00 | 0.82 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.192430E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604041E+10 | 0.00 | 0.00 | 0.38 |
February | 0.238040E+10 | 0.00 | 0.00 | 169255.91 | 0.00 | 0.304763E+10 | 0.170743E+09 | 0.00 | 0.40 |
March | 0.330088E+10 | 0.00 | 0.00 | 5787.33 | 0.00 | 0.196079E+10 | 4168641.25 | 0.00 | 0.39 |
April | 0.260972E+10 | 0.00 | 0.00 | 1086022.36 | 0.00 | 0.537843E+09 | 0.995041E+09 | 0.00 | 0.51 |
May | 0.190049E+10 | 22438913.70 | 0.00 | 3952142.23 | 720941.27 | 0.269583E+09 | 0.213339E+10 | 0.00 | 0.76 |
June | 0.273893E+09 | 0.269883E+09 | 0.00 | 7494429.78 | 0.00 | 0.00 | 0.329203E+10 | 0.00 | 1.04 |
July | 19947493.72 | 0.712741E+09 | 0.00 | 7303554.53 | 120605.70 | 0.00 | 0.206362E+10 | 0.00 | 0.94 |
August | 0.121611E+09 | 0.509962E+09 | 0.00 | 8620009.63 | 296830.63 | 0.00 | 0.291148E+10 | 0.00 | 1.06 |
September | 0.793684E+09 | 0.260901E+09 | 0.00 | 6645721.30 | 0.00 | 0.00 | 0.333364E+10 | 0.00 | 0.95 |
October | 0.214454E+10 | 2187134.39 | 0.00 | 4103525.55 | 0.00 | 17319652.55 | 0.305756E+10 | 0.00 | 0.71 |
November | 0.330242E+10 | 0.00 | 0.00 | 511717.94 | 0.00 | 0.116327E+10 | 0.471285E+09 | 0.00 | 0.42 |
December | 0.266407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.394605E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.214360E+11 | 0.177811E+10 | 0.00 | 39892166.57 | 1138377.60 | 0.169829E+11 | 0.184330E+11 | 0.00 | 0.66 |
Minimum of Months | 19947493.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.330242E+10 | 0.712741E+09 | 0.00 | 8620009.63 | 720941.27 | 0.604041E+10 | 0.333364E+10 | 0.00 | 1.06 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.135455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.708613E+10 | 0.00 | 0.00 | 0.41 |
February | 0.195930E+10 | 0.00 | 0.00 | 53855.12 | 0.00 | 0.387016E+10 | 71429479.74 | 0.00 | 0.42 |
March | 0.310493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252071E+10 | 0.00 | 0.00 | 0.42 |
April | 0.286919E+10 | 0.00 | 0.00 | 415191.37 | 0.00 | 0.641496E+09 | 0.444175E+09 | 0.00 | 0.48 |
May | 0.211228E+10 | 20781618.56 | 0.00 | 1629410.65 | 1941062.48 | 0.381053E+09 | 0.122212E+10 | 0.00 | 0.64 |
June | 0.473848E+09 | 0.250780E+09 | 0.00 | 3851642.31 | 5117858.61 | 0.00 | 0.224012E+10 | 0.00 | 0.86 |
July | 99420332.32 | 0.607961E+09 | 0.00 | 3719446.58 | 29468471.03 | 0.00 | 0.137381E+10 | 0.00 | 0.78 |
August | 0.289279E+09 | 0.454803E+09 | 0.00 | 4569970.79 | 17972087.60 | 0.00 | 0.202424E+10 | 0.00 | 0.89 |
September | 0.112950E+10 | 0.217323E+09 | 0.00 | 3575821.75 | 14236863.69 | 1765084.32 | 0.213450E+10 | 0.00 | 0.80 |
October | 0.248669E+10 | 2380242.27 | 0.00 | 2040420.54 | 0.00 | 0.172427E+09 | 0.170937E+10 | 0.00 | 0.62 |
November | 0.317748E+10 | 0.00 | 0.00 | 97112.09 | 0.00 | 0.162921E+10 | 0.146568E+09 | 0.00 | 0.42 |
December | 0.228288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.475606E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.213393E+11 | 0.155403E+10 | 0.00 | 19952871.22 | 68736343.41 | 0.210590E+11 | 0.113663E+11 | 0.00 | 0.60 |
Minimum of Months | 99420332.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.317748E+10 | 0.607961E+09 | 0.00 | 4569970.79 | 29468471.03 | 0.708613E+10 | 0.224012E+10 | 0.00 | 0.89 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.121502E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.722553E+10 | 0.00 | 0.00 | 0.41 |
February | 0.181170E+10 | 0.00 | 0.00 | 35613.88 | 0.00 | 0.401806E+10 | 55994630.33 | 0.00 | 0.42 |
March | 0.289778E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271962E+10 | 0.00 | 0.00 | 0.42 |
April | 0.280179E+10 | 0.00 | 0.00 | 345641.09 | 0.00 | 0.712360E+09 | 0.390337E+09 | 0.00 | 0.48 |
May | 0.206851E+10 | 20429662.42 | 0.00 | 1509304.23 | 2473063.37 | 0.440401E+09 | 0.115061E+10 | 0.00 | 0.64 |
June | 0.483105E+09 | 0.250565E+09 | 0.00 | 3785781.88 | 5114712.34 | 0.00 | 0.221234E+10 | 0.00 | 0.86 |
July | 0.100936E+09 | 0.607988E+09 | 0.00 | 3730876.78 | 29445153.08 | 0.00 | 0.137487E+10 | 0.00 | 0.78 |
August | 0.294941E+09 | 0.454713E+09 | 0.00 | 4560577.47 | 17938882.77 | 0.00 | 0.202262E+10 | 0.00 | 0.90 |
September | 0.113738E+10 | 0.217345E+09 | 0.00 | 3502153.75 | 14205322.49 | 3271739.09 | 0.209767E+10 | 0.00 | 0.79 |
October | 0.250736E+10 | 2382658.59 | 0.00 | 1872693.31 | 0.00 | 0.210745E+09 | 0.157901E+10 | 0.00 | 0.61 |
November | 0.304297E+10 | 0.00 | 0.00 | 65535.14 | 0.00 | 0.178112E+10 | 99170290.18 | 0.00 | 0.42 |
December | 0.209213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.494563E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.204536E+11 | 0.155342E+10 | 0.00 | 19408177.52 | 69177134.05 | 0.220567E+11 | 0.109826E+11 | 0.00 | 0.59 |
Minimum of Months | 0.100936E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.304297E+10 | 0.607988E+09 | 0.00 | 4560577.47 | 29445153.08 | 0.722553E+10 | 0.221234E+10 | 0.00 | 0.90 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.941023E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.749935E+10 | 0.00 | 0.00 | 0.41 |
February | 0.160867E+10 | 0.00 | 0.00 | 16715.58 | 0.00 | 0.423204E+10 | 26070760.18 | 0.00 | 0.41 |
March | 0.260557E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.300051E+10 | 0.00 | 0.00 | 0.42 |
April | 0.260355E+10 | 0.00 | 0.00 | 238662.27 | 0.00 | 0.920463E+09 | 0.295327E+09 | 0.00 | 0.46 |
May | 0.196666E+10 | 20436906.73 | 0.00 | 1200957.04 | 2821946.03 | 0.599254E+09 | 0.946730E+09 | 0.00 | 0.61 |
June | 0.526405E+09 | 0.249483E+09 | 0.00 | 3372102.33 | 5144678.35 | 0.00 | 0.202414E+10 | 0.00 | 0.83 |
July | 0.115519E+09 | 0.607249E+09 | 0.00 | 3447278.14 | 29882506.67 | 0.00 | 0.130265E+10 | 0.00 | 0.77 |
August | 0.344459E+09 | 0.454847E+09 | 0.00 | 4212910.79 | 18165430.46 | 0.00 | 0.188911E+10 | 0.00 | 0.88 |
September | 0.119377E+10 | 0.216475E+09 | 0.00 | 3117597.36 | 14335907.40 | 3806710.07 | 0.190627E+10 | 0.00 | 0.77 |
October | 0.256210E+10 | 2375640.92 | 0.00 | 1483998.52 | 0.00 | 0.245028E+09 | 0.130772E+10 | 0.00 | 0.58 |
November | 0.279452E+10 | 0.00 | 0.00 | 30440.96 | 0.00 | 0.203018E+10 | 50730000.35 | 0.00 | 0.41 |
December | 0.177154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.526507E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.190338E+11 | 0.155087E+10 | 0.00 | 17120662.99 | 70350468.90 | 0.237957E+11 | 0.974875E+10 | 0.00 | 0.58 |
Minimum of Months | 0.115519E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.279452E+10 | 0.607249E+09 | 0.00 | 4212910.79 | 29882506.67 | 0.749935E+10 | 0.202414E+10 | 0.00 | 0.88 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.476366E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150618E+11 | 0.00 | 0.00 | 0.38 |
February | 0.172292E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.898339E+10 | 0.00 | 0.00 | 0.38 |
March | 0.356903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.665458E+10 | 0.00 | 0.00 | 0.39 |
April | 0.381889E+10 | 0.00 | 0.00 | 99364.90 | 0.00 | 0.262732E+10 | 0.108486E+09 | 0.00 | 0.39 |
May | 0.340060E+10 | 28763964.43 | 0.00 | 1325042.34 | 5484558.39 | 0.148385E+10 | 0.641643E+09 | 0.00 | 0.43 |
June | 0.122622E+10 | 0.480593E+09 | 0.00 | 4129465.73 | 278406.98 | 0.00 | 0.183203E+10 | 0.00 | 0.53 |
July | 0.187343E+09 | 0.120791E+10 | 0.00 | 4901505.44 | 22737814.51 | 0.00 | 0.126244E+10 | 0.00 | 0.51 |
August | 0.466933E+09 | 0.853514E+09 | 0.00 | 6163636.51 | 26180077.78 | 0.00 | 0.208391E+10 | 0.00 | 0.56 |
September | 0.243412E+10 | 0.395130E+09 | 0.00 | 3859475.62 | 27299712.75 | 27995405.20 | 0.171584E+10 | 0.00 | 0.51 |
October | 0.487858E+10 | 1783448.97 | 0.00 | 1285544.01 | 0.00 | 0.704183E+09 | 0.848388E+09 | 0.00 | 0.43 |
November | 0.406670E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.468570E+10 | 0.00 | 0.00 | 0.38 |
December | 0.149911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114107E+11 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.277468E+11 | 0.296770E+10 | 0.00 | 21764034.55 | 81980570.40 | 0.516396E+11 | 0.849274E+10 | 0.00 | 0.44 |
Minimum of Months | 0.187343E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.487858E+10 | 0.120791E+10 | 0.00 | 6163636.51 | 27299712.75 | 0.150618E+11 | 0.208391E+10 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.179793E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.758217E+10 | 0.00 | 0.00 | 0.38 |
February | 0.801839E+09 | 0.00 | 0.00 | 1502.72 | 0.00 | 0.454831E+10 | 5020306.30 | 0.00 | 0.38 |
March | 0.160211E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350465E+10 | 0.00 | 0.00 | 0.39 |
April | 0.181267E+10 | 0.00 | 0.00 | 62555.70 | 0.00 | 0.140008E+10 | 78092295.03 | 0.00 | 0.38 |
May | 0.158377E+10 | 13862565.68 | 0.00 | 712144.85 | 2766261.99 | 0.842611E+09 | 0.270039E+09 | 0.00 | 0.38 |
June | 0.475648E+09 | 0.230572E+09 | 0.00 | 2180836.37 | 103474.96 | 0.00 | 0.771804E+09 | 0.00 | 0.39 |
July | 70993302.33 | 0.599504E+09 | 0.00 | 2234333.27 | 10550578.97 | 0.00 | 0.397300E+09 | 0.00 | 0.38 |
August | 0.202795E+09 | 0.435214E+09 | 0.00 | 2887106.37 | 12698521.64 | 0.00 | 0.670334E+09 | 0.00 | 0.39 |
September | 0.111990E+10 | 0.195520E+09 | 0.00 | 1890381.80 | 13150172.44 | 13302340.03 | 0.650704E+09 | 0.00 | 0.38 |
October | 0.231739E+10 | 954652.35 | 0.00 | 748061.63 | 0.00 | 0.400005E+09 | 0.424577E+09 | 0.00 | 0.38 |
November | 0.195885E+10 | 0.00 | 0.00 | 1039.72 | 0.00 | 0.242443E+10 | 7968061.54 | 0.00 | 0.38 |
December | 0.655108E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.579230E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.127809E+11 | 0.147563E+10 | 0.00 | 10717962.45 | 39269010.00 | 0.265079E+11 | 0.327584E+10 | 0.00 | 0.38 |
Minimum of Months | 70993302.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.231739E+10 | 0.599504E+09 | 0.00 | 2887106.37 | 13150172.44 | 0.758217E+10 | 0.771804E+09 | 0.00 | 0.39 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.151997E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761009E+10 | 0.00 | 0.00 | 0.38 |
February | 0.729376E+09 | 0.00 | 0.00 | 708.02 | 0.00 | 0.462059E+10 | 3384630.69 | 0.00 | 0.38 |
March | 0.148814E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.361798E+10 | 0.00 | 0.00 | 0.39 |
April | 0.174497E+10 | 0.00 | 0.00 | 52271.25 | 0.00 | 0.147001E+10 | 69005189.86 | 0.00 | 0.38 |
May | 0.156320E+10 | 13873991.49 | 0.00 | 663588.93 | 2866954.40 | 0.867668E+09 | 0.259401E+09 | 0.00 | 0.38 |
June | 0.501614E+09 | 0.230355E+09 | 0.00 | 2073996.67 | 105421.69 | 0.00 | 0.744531E+09 | 0.00 | 0.39 |
July | 75514362.78 | 0.599650E+09 | 0.00 | 2176876.59 | 10621351.20 | 0.00 | 0.393749E+09 | 0.00 | 0.38 |
August | 0.206369E+09 | 0.435359E+09 | 0.00 | 2812271.45 | 12746500.48 | 0.00 | 0.667789E+09 | 0.00 | 0.39 |
September | 0.112071E+10 | 0.195347E+09 | 0.00 | 1833221.19 | 13211171.74 | 29353467.70 | 0.631514E+09 | 0.00 | 0.38 |
October | 0.230758E+10 | 945021.69 | 0.00 | 708343.69 | 0.00 | 0.432373E+09 | 0.395709E+09 | 0.00 | 0.38 |
November | 0.189113E+10 | 0.00 | 0.00 | 31.75 | 0.00 | 0.249323E+10 | 3384170.25 | 0.00 | 0.38 |
December | 0.578669E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.586880E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.123593E+11 | 0.147553E+10 | 0.00 | 10321309.53 | 39551399.51 | 0.270101E+11 | 0.316847E+10 | 0.00 | 0.38 |
Minimum of Months | 75514362.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.230758E+10 | 0.599650E+09 | 0.00 | 2812271.45 | 13211171.74 | 0.761009E+10 | 0.744531E+09 | 0.00 | 0.39 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 80795209.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.768136E+10 | 0.00 | 0.00 | 0.38 |
February | 0.504776E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.484326E+10 | 0.00 | 0.00 | 0.38 |
March | 0.115237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.395203E+10 | 0.00 | 0.00 | 0.39 |
April | 0.153612E+10 | 0.00 | 0.00 | 25123.97 | 0.00 | 0.169001E+10 | 36801140.78 | 0.00 | 0.38 |
May | 0.140049E+10 | 13885027.07 | 0.00 | 517577.24 | 3208440.16 | 0.105387E+10 | 0.210914E+09 | 0.00 | 0.38 |
June | 0.618245E+09 | 0.228879E+09 | 0.00 | 1736351.91 | 109017.60 | 1190931.72 | 0.613117E+09 | 0.00 | 0.39 |
July | 93574256.86 | 0.598579E+09 | 0.00 | 2010373.29 | 10756181.48 | 0.00 | 0.376103E+09 | 0.00 | 0.38 |
August | 0.227565E+09 | 0.435292E+09 | 0.00 | 2602061.24 | 12832301.28 | 0.00 | 0.642904E+09 | 0.00 | 0.39 |
September | 0.112410E+10 | 0.194403E+09 | 0.00 | 1654882.49 | 13320252.24 | 85903956.07 | 0.558741E+09 | 0.00 | 0.38 |
October | 0.222306E+10 | 940464.97 | 0.00 | 576520.14 | 0.00 | 0.553290E+09 | 0.330687E+09 | 0.00 | 0.38 |
November | 0.163697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274047E+10 | 0.00 | 0.00 | 0.38 |
December | 0.318031E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.612948E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.109161E+11 | 0.147198E+10 | 0.00 | 9122890.27 | 40226192.75 | 0.287309E+11 | 0.276927E+10 | 0.00 | 0.38 |
Minimum of Months | 80795209.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.222306E+10 | 0.598579E+09 | 0.00 | 2602061.24 | 13320252.24 | 0.768136E+10 | 0.642904E+09 | 0.00 | 0.39 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:21:27
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 4801834.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.774446E+10 | 0.00 | 0.00 | 0.38 |
February | 0.237766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.509364E+10 | 0.00 | 0.00 | 0.38 |
March | 0.274519E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.481006E+10 | 0.00 | 0.00 | 0.39 |
April | 0.749997E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.247053E+10 | 0.00 | 0.00 | 0.38 |
May | 0.990488E+09 | 14522715.47 | 0.00 | 282252.67 | 3789919.33 | 0.149773E+10 | 0.248469E+09 | 0.00 | 0.46 |
June | 0.669759E+09 | 0.229570E+09 | 0.00 | 1245257.76 | 112790.87 | 96781490.65 | 0.829751E+09 | 0.00 | 0.62 |
July | 0.164626E+09 | 0.588462E+09 | 0.00 | 1834286.12 | 11175960.78 | 0.00 | 0.745216E+09 | 0.00 | 0.63 |
August | 0.276186E+09 | 0.428033E+09 | 0.00 | 2317382.85 | 13095005.72 | 0.00 | 0.125732E+10 | 0.00 | 0.72 |
September | 0.966253E+09 | 0.189887E+09 | 0.00 | 1470044.94 | 13188919.32 | 0.296777E+09 | 0.104584E+10 | 0.00 | 0.62 |
October | 0.188129E+10 | 1246933.32 | 0.00 | 406764.35 | 0.00 | 0.909896E+09 | 0.455793E+09 | 0.00 | 0.46 |
November | 0.969380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.338517E+10 | 0.00 | 0.00 | 0.38 |
December | 15479621.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.642186E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.720055E+10 | 0.145172E+10 | 0.00 | 7555988.70 | 41362596.02 | 0.327269E+11 | 0.458239E+10 | 0.00 | 0.48 |
Minimum of Months | 4801834.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.188129E+10 | 0.588462E+09 | 0.00 | 2317382.85 | 13188919.32 | 0.774446E+10 | 0.125732E+10 | 0.00 | 0.72 |