Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:20
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000
Simulation Timestamp: 2020-06-03 19:20:51
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1511.69 | 723.19 | 723.19 |
Net Site Energy | 1511.69 | 723.19 | 723.19 |
Total Source Energy | 4787.53 | 2290.34 | 2290.34 |
Net Source Energy | 4787.53 | 2290.34 | 2290.34 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 698.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 450.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 59.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 117.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 57.52 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1511.69 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 698.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 450.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 59.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 117.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 57.52 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 244.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 417.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 723.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 244.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 417.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 723.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1511.693 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1511.693 | 100.00 |
Total On-Site and Utility Electric Sources | 1511.693 | 100.00 |
Total Electricity End Uses | 1511.693 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 3.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2686.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:20 |
RunPeriod | RUNPERIOD 1 |
Weather File | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Latitude [deg] | 10.82 |
Longitude [deg] | 106.67 |
Elevation [m] | 5.00 |
Time Zone | 7.00 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 16.9114 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 19.7854 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.1708 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.1708 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 18.1708 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 11.2173 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 11.2173 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 14.6187 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 14.6187 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 13-JUN-13:50 | - | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 77597.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 29013.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 12443.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 9647.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 136761.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 77597.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 29013.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 12443.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 9647.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 2212.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1427.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 188.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 405.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 370.83 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 182.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4787.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1058.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 683.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 90.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 177.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 87.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2290.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1058.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 683.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 90.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 177.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 87.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2290.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 2.10 |
SMSTORE1 DIRECT AIR | 1.10 |
SMSTORE2 DIRECT AIR | 1.10 |
SMSTORE3 DIRECT AIR | 1.11 |
SMSTORE4 DIRECT AIR | 1.10 |
LGSTORE2 DIRECT AIR | 1.91 |
SMSTORE5 DIRECT AIR | 1.01 |
SMSTORE6 DIRECT AIR | 1.00 |
SMSTORE7 DIRECT AIR | 1.00 |
SMSTORE8 DIRECT AIR | 1.14 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 2.10 | 2.10 | 2.10 | 2.10 | 2.10 | 2.10 | 1.00 | 1.00 | 2.10 |
PSZ-AC_2:2 | 1.10 | 1.10 | 1.10 | 1.10 | 1.10 | 1.10 | 1.00 | 1.00 | 1.10 |
PSZ-AC_3:3 | 1.10 | 1.10 | 1.10 | 1.10 | 1.10 | 1.10 | 1.00 | 0.999966 | 1.10 |
PSZ-AC_4:4 | 1.11 | 1.11 | 1.11 | 1.11 | 1.11 | 1.11 | 1.00 | 1.000000 | 1.11 |
PSZ-AC_5:5 | 1.10 | 1.10 | 1.10 | 1.10 | 1.10 | 1.10 | 1.00 | 0.999996 | 1.10 |
PSZ-AC_6:6 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.00 | 1.000000 | 1.91 |
PSZ-AC_7:7 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.01 | 1.00 | 0.999935 | 1.01 |
PSZ-AC_8:8 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 0.999938 | 1.00 |
PSZ-AC_9:9 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.000000 | 1.00 |
PSZ-AC_10:10 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.00 | 1.00 | 1.14 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 2.10 | 0.411453 |
PSZ-AC_2:2_OA_CONTROLLER | 1.10 | 0.205727 |
PSZ-AC_3:3_OA_CONTROLLER | 1.10 | 0.205727 |
PSZ-AC_4:4_OA_CONTROLLER | 1.11 | 0.205727 |
PSZ-AC_5:5_OA_CONTROLLER | 1.10 | 0.205727 |
PSZ-AC_6:6_OA_CONTROLLER | 1.91 | 0.411453 |
PSZ-AC_7:7_OA_CONTROLLER | 1.01 | 0.205727 |
PSZ-AC_8:8_OA_CONTROLLER | 1.00 | 0.205727 |
PSZ-AC_9:9_OA_CONTROLLER | 1.00 | 0.205727 |
PSZ-AC_10:10_OA_CONTROLLER | 1.14 | 0.205727 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 2.10 | 2.10 | 2.10 | 1.39 | 52267.15 | 48587.89 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 1.10 | 1.10 | 1.10 | 0.726595 | 27338.02 | 25402.03 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.10 | 1.10 | 1.10 | 0.728223 | 27399.25 | 25457.38 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 1.11 | 1.11 | 1.11 | 0.730436 | 27482.52 | 25592.39 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 1.10 | 1.10 | 1.10 | 0.724062 | 27242.72 | 25313.88 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 1.91 | 1.91 | 1.91 | 1.26 | 47508.14 | 44910.44 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 1.01 | 1.01 | 1.01 | 0.663725 | 24972.54 | 23224.04 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 1.00 | 1.00 | 1.00 | 0.660385 | 24846.87 | 23108.53 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 1.00 | 1.00 | 1.00 | 0.662281 | 24918.20 | 23553.07 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 1.14 | 1.14 | 1.14 | 0.752222 | 28302.20 | 26288.55 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 2.10 | 1.05 | 1.40 | 52166.43 | 52267.15 | 26133.58 | 26133.58 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 1.10 | 0.550450 | 0.733933 | 27212.02 | 27338.02 | 13669.01 | 13669.01 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 1.10 | 0.551685 | 0.735580 | 27259.96 | 27399.25 | 13699.62 | 13699.62 | 0.676084 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 1.11 | 0.553360 | 0.737813 | 27317.35 | 27482.52 | 13741.26 | 13741.26 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 1.10 | 0.548530 | 0.731373 | 27155.06 | 27242.72 | 13621.36 | 13621.36 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 1.91 | 0.956575 | 1.28 | 47508.07 | 47508.14 | 23754.07 | 23754.07 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 1.01 | 0.502820 | 0.670427 | 24972.44 | 24972.54 | 12486.27 | 12486.27 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 1.00 | 0.500290 | 0.667053 | 24846.78 | 24846.87 | 12423.43 | 12423.43 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 1.00 | 0.501730 | 0.668973 | 24918.30 | 24918.20 | 12459.10 | 12459.10 | 0.676084 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 1.14 | 0.569865 | 0.759820 | 27718.40 | 28302.20 | 14151.10 | 14151.10 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.10 | 2252.23 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 1.10 | 1218.87 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.10 | 1221.60 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.11 | 1225.32 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 1.10 | 1214.62 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 1.91 | 2047.16 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 1.01 | 1113.41 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 1.00 | 1107.80 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 1.00 | 1110.98 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 1.14 | 1261.86 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 48587.89 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 25402.03 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 25457.38 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 25592.39 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 25313.88 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 44910.44 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 23224.04 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 23108.53 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 23553.07 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 26288.55 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 26.90 | 26.70 | 26.00 | 26.40 | 27.50 | 28.30 | 29.20 | 29.00 | 28.90 | 27.20 | 27.50 | 27.60 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 | 10.82 | 106.67 | 7.00 | 5.00 | 101265 | 1.2036 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 27.60 | 3.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 16.911 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 21.211 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 19.785 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 24.085 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.171 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.471 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.171 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.471 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.171 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.471 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 11.217 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 15.517 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 3907.969 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3907.969 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 1983.747 | 5.694 | 66.133 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1983.747 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1492.505 | 8.568 | 99.514 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1492.505 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1211.252 | 6.954 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.252 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1211.252 | 6.954 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.252 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1211.252 | 6.954 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.252 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 3907.969 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3907.969 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 1953.984 | 11.217 | 130.283 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1953.984 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.7871 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1995 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2888 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.037 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.937 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.386 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1010000 | 2.1010000 | 2.1010000 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
19 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
20 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
21 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
22 | 7 | -0.29735092E-12 | 0.24575595E-14 | -0.94456721E-13 | 0.15324278E-15 |
23 | 6 | 0.28546880E-07 | 0.22114619E-09 | 0.65405332E-08 | -0.13451374E-12 |
24 | 5 | -0.18947583E-03 | 0.18937623E-05 | -0.97466953E-04 | 0.64660656E-08 |
25 | 4 | 0.29140875 | 0.92215111E-03 | 0.99417931E-01 | -0.33466744E-04 |
26 | 3 | -7.2517161 | 0.28579858E-01 | -2.3345767 | 0.28937395E-01 |
27 | 2 | 40.822959 | 0.10163225 | 15.247323 | -0.33280368 |
28 | 1 | -80.508872 | 0.45869584E-01 | -29.125752 | 1.0778326 |
29 | 0 | 46.824339 | 0.92288667E-03 | 16.291614 | |
30 | 7 | -0.21163652E-08 | -0.68723841E-15 | 0.43910983E-14 | -0.57684426E-16 |
31 | 6 | 0.56109385E-05 | 0.38186281E-08 | 0.31898696E-02 | -0.26759299E-04 |
32 | 5 | -0.40164657E-03 | 0.22608617E-05 | -0.22372456 | 0.19561502E-02 |
33 | 4 | 0.92272104E-02 | 0.10289840E-03 | 4.8295456 | -0.45264980E-01 |
34 | 3 | -0.80993241E-01 | 0.81813938E-03 | -38.021416 | 0.39865375 |
35 | 2 | 0.28754352 | 0.13608947E-02 | 116.48395 | -1.4179393 |
36 | 1 | -0.41499682 | 0.41453381E-03 | -143.90731 | 2.0490399 |
37 | 0 | 0.20232414 | 0.10048102E-04 | 60.838472 | |
38 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
39 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
40 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
41 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
42 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
43 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
44 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
45 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
46 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
47 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
48 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
49 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
50 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
51 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
52 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
53 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
54 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
55 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
56 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
57 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
58 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
59 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
60 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
61 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
62 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
63 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
64 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
65 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
66 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
67 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
68 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
69 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
70 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
71 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
72 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
73 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
74 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
75 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
76 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
77 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
78 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
79 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
80 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
81 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
82 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
83 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
84 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
85 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
86 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
87 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
88 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
89 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
90 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
91 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
92 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
93 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
94 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479936E-14 | -0.41635794E-16 |
95 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
96 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
97 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
98 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
99 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
100 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
101 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
102 | 7 | -0.14484255E-08 | -0.22640907E-15 | 0.11860658E-13 | -0.17473455E-15 |
103 | 6 | 0.80640390E-05 | 0.55493782E-08 | 0.31828288E-02 | -0.26700235E-04 |
104 | 5 | -0.58275339E-03 | 0.32892043E-05 | -0.22332434 | 0.19526176E-02 |
105 | 4 | 0.13421983E-01 | 0.14977251E-03 | 4.8228790 | -0.45200897E-01 |
106 | 3 | -0.11791368 | 0.11914425E-02 | -37.983753 | 0.39823745 |
107 | 2 | 0.41875064 | 0.19825898E-02 | 116.41064 | -1.4169588 |
108 | 1 | -0.60444169 | 0.60433957E-03 | -143.86415 | 2.0483306 |
109 | 0 | 0.29470347 | 0.14596444E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 29 | 1 | VerySmooth | 2.843 | 0.222 | 0.132 | 0.242 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 1.97990E-002 | 0.13126 | 0.64095 | 0.64095 | 0.24200 | 0.16318 | 0.24318 | 0.00000 | 0.84000 | 0.84000 | 0.10909 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.159 | 4.569E-004 | 2.517E-004 | 0.317 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 6.149E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 4.561E-002 | 2.619E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.648E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 9.122E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 7.565E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.113 | 6.514E-004 | 3.022E-004 | 0.453 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 5.921E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 23880.15527 | 28656.18633 | 1.75400 | 2.10480 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | 35.11500 | 1.71339E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
2 | LGSTORE1 | Heating | 1900.07938 | 2280.09525 | 8.01854E-002 | 0.41145 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
3 | SMSTORE1 | Cooling | 12490.24608 | 14988.29529 | 0.91742 | 1.10090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:40:00 | 35.05833 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
4 | SMSTORE1 | Heating | 913.75643 | 1096.50771 | 3.86879E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
5 | SMSTORE2 | Cooling | 12518.82649 | 15022.59179 | 0.91944 | 1.10333 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 34.91667 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
6 | SMSTORE2 | Heating | 991.49737 | 1189.79685 | 4.19669E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
7 | SMSTORE3 | Cooling | 12557.29910 | 15068.75892 | 0.92227 | 1.10672 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 34.91667 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
8 | SMSTORE3 | Heating | 1026.97347 | 1232.36817 | 4.34349E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
9 | SMSTORE4 | Cooling | 12447.68928 | 14937.22713 | 0.91422 | 1.09706 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 34.91667 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
10 | SMSTORE4 | Heating | 1173.78255 | 1408.53907 | 4.95249E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
11 | LGSTORE2 | Cooling | 21708.31786 | 26049.98143 | 1.59429 | 1.91315 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 34.91667 | 1.71339E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
12 | LGSTORE2 | Heating | 2210.83269 | 2652.99923 | 9.29322E-002 | 0.41145 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
13 | SMSTORE5 | Cooling | 11410.56419 | 13692.67702 | 0.83798 | 1.00558 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 34.84583 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
14 | SMSTORE5 | Heating | 1106.42596 | 1327.71116 | 4.67342E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
15 | SMSTORE6 | Cooling | 11353.18729 | 13623.82475 | 0.83377 | 1.00052 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 34.84583 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
16 | SMSTORE6 | Heating | 1097.97702 | 1317.57242 | 4.63834E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
17 | SMSTORE7 | Cooling | 11386.48123 | 13663.77747 | 0.83621 | 1.00346 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 34.84583 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
18 | SMSTORE7 | Heating | 1209.43786 | 1451.32543 | 5.09790E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
19 | SMSTORE8 | Cooling | 12933.60240 | 15520.32288 | 0.94977 | 1.13973 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | 34.77500 | 1.71339E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
20 | SMSTORE8 | Heating | 1240.52572 | 1488.63086 | 5.23498E-002 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 20.10000 | 1.47983E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 33835.52 | 2.10480 | 2.10480 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 9902.82 | 0.41145 | 0.41145 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 17563.69 | 1.10090 | 1.10090 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 17586.05 | 1.10337 | 1.10337 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:50:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 17628.82 | 1.10672 | 1.10672 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:20:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 17500.12 | 1.09706 | 1.09706 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 31233.25 | 1.91315 | 1.91315 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 9902.82 | 0.41145 | 0.41145 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 16270.85 | 1.00564 | 1.00564 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 16203.02 | 1.00058 | 1.00058 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 16235.55 | 1.00346 | 1.00346 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:40:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 17989.85 | 1.13973 | 1.13973 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 4951.41 | 0.20573 | 0.20573 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.10480 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.10090 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.10333 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.10672 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.09706 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.91315 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00558 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00052 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00346 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.13973 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.10480 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.10480 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.10480 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.10480 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.10480 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.10480 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.10090 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.10090 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.10090 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.10090 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.10090 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 1.10090 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.10333 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.10333 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.10333 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.10333 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.10337 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.10337 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 0.99997 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.10672 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.10672 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.10672 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.10672 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.10672 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.10672 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.09706 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.09706 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.09706 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.09706 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.09706 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 1.09706 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 1.00000 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.91315 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.91315 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.91315 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.91315 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.91315 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 1.91315 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00558 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00558 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00558 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00558 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00564 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 1.00564 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 0.99993 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00052 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00052 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00052 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00052 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00058 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 1.00058 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 0.99994 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00346 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00346 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00346 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00346 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00346 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 1.00346 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 1.00000 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.13973 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.13973 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.13973 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.13973 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.13973 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 1.13973 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 1.00000 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 2.10480 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 1.10090 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.10337 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 1.10672 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 1.09706 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 1.91315 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 1.00564 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 1.00058 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 1.00346 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 1.13973 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.10480 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.10480 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.10480 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.10480 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.38917 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.10480 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.05240 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.40320 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 52166.42872 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 52267.15000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 26133.57500 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 26133.57500 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 52267.15000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 48587.89206 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.10480 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2252.23370 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 48587.89206 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.10090 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.10090 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.10090 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.10090 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.72660 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.10090 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.55045 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.73393 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 27212.01887 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27338.02000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13669.01000 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 13669.01000 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27338.02000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25402.03090 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.10090 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1218.87326 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25402.03090 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.10337 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.10337 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.10337 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.10337 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.72822 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.10337 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.55169 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.73558 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 27259.96455 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27399.25000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13699.62500 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 13699.62500 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27399.25000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25457.38009 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.10337 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1221.60337 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25457.38009 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.10672 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.10672 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.10672 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.10672 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.73044 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.10672 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.55336 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.73781 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 27317.34803 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27482.52000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13741.26000 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 13741.26000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27482.52000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25592.38895 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.10672 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1225.31586 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25592.38895 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.09706 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.09706 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.09706 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.09706 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.72406 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.09706 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.54853 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.73137 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 27155.06177 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27242.72000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13621.36000 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 13621.36000 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27242.72000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25313.87810 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.09706 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1214.62416 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25313.87810 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.91315 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.91315 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.91315 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.91315 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.26268 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.91315 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.95658 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.27543 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 47508.07052 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 47508.14000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 23754.07000 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 23754.07000 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 47508.14000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 44910.43968 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.91315 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2047.16378 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 44910.43968 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00564 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00564 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00564 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00564 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66373 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.00564 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50282 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.67043 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24972.43606 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 24972.54000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12486.27000 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 12486.27000 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 24972.54000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 23224.03992 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.00564 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1113.40753 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 23224.03992 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00058 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00058 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00058 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00058 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66039 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.00058 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50029 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66705 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24846.78421 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 24846.87000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12423.43500 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 12423.43500 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 24846.87000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 23108.52772 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.00058 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1107.80478 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 23108.52772 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00346 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00346 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00346 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00346 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66228 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.00346 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50173 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66897 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 24918.30147 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 24918.20000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12459.10000 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 12459.10000 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 24918.20000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 23553.07466 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.00346 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1110.98482 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 23553.07466 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.13973 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.13973 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.13973 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.13973 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.75222 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.13973 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.56987 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.75982 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 27718.39931 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 28302.20000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 14151.10000 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14151.10000 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 28302.20000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26288.55309 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.13973 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1261.86157 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 26288.55309 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 50606.6 | 11.77 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 26469.5 | 34.79 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 26528.8 | 46.66 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 26609.4 | 58.47 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 26377.2 | 70.93 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 45998.8 | 51.83 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 24179.2 | 112.06 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 24057.5 | 124.57 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 24126.6 | 136.17 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 27403.1 | 131.83 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.199 | 0.190 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.22 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.289 | 0.270 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 6 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 2.8503583265E-002 | 0.1641698364 | Pass | Pass | 4.8078367999E-002 | 0.2938745143 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 2.9715845454E-002 | 0.1859425851 | Pass | Pass | 3.1274666466E-002 | 0.1424472679 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 4.1355985681E-002 | 0.2041872063 | Pass | Pass | 0.1184526239 | 0.9032717123 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 4.1501503649E-002 | 0.2060494384 | Pass | Pass | 0.1157673779 | 0.8995601924 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 4.0548596807E-002 | 0.1979697673 | Pass | Pass | 0.1342316292 | 0.9182557112 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 3.9604320400E-002 | 0.1915162223 | Pass | Pass | 9.9512281637E-002 | 0.7608894755 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 3.8667702599E-002 | 0.1889904099 | Pass | Pass | 0.1056658661 | 0.7535571008 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 3.8484657485E-002 | 0.1876088960 | Pass | Pass | 0.1047522825 | 0.7458849311 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 3.8347009220E-002 | 0.1835210527 | Pass | Pass | 0.1316900243 | 0.8575463072 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 4.1933196524E-002 | 0.1942699174 | Pass | Pass | 0.1938650908 | 1.3427482050 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 20.10 | 0.00 | 20.10 | Wetbulb [C] | 1.80 | 0.00 |
HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 35.20 | 8.50 | 25.80 | Wetbulb [C] | 4.10 | 160.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.199 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.289 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.843 | 0.222 | 0.242 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.843 | 0.222 | 0.242 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.843 | 0.222 | 0.242 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.222 | 0.242 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.22 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.222 | 0.242 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 2.843 | 0.222 | 0.242 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 2.843 | 0.222 | 0.242 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 11.2173 | 348.39 | 3907.97 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 168.00 | 96.33 | 0.0000 | Y | 70.67 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 5.6941 | 348.39 | 1983.75 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 112.00 | 95.26 | 0.0000 | Y | 35.47 |
SMSTORE1_LIGHTS | SMSTORE1 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 168.00 | 96.33 | 0.0000 | Y | 35.33 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 8.5681 | 174.19 | 1492.50 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 112.00 | 95.26 | 0.0000 | Y | 26.69 |
SMSTORE2_LIGHTS | SMSTORE2 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 74.85 | 0.0000 | Y | 27.46 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
SMSTORE3_LIGHTS | SMSTORE3 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 74.85 | 0.0000 | Y | 27.46 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
SMSTORE4_LIGHTS | SMSTORE4 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 74.85 | 0.0000 | Y | 27.46 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
LGSTORE2_LIGHTS | LGSTORE2 | 11.2173 | 348.39 | 3907.97 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 50.13 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 11.2173 | 174.19 | 1953.98 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.34 | 0.0000 | Y | 25.07 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 7.3094 | 4180.64 | 30557.82 | 450.89 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 418.40 | AstronomicalClock | - | 41.93 | 41.93 | 3.29 | |
EXTERIOR_LIGHTS_B | 2520.30 | AstronomicalClock | - | 83.83 | 62.88 | 29.75 | |
EXTERIOR_LIGHTS_C | 2520.30 | AstronomicalClock | - | 83.83 | 55.88 | 26.44 | |
Exterior Lighting Total | 5459.01 | 59.48 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 52267.15 | 35336.77 | 16930.38 | 0.68 | 3.73 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27338.02 | 18482.69 | 8855.33 | 0.68 | 3.80 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27399.25 | 18524.08 | 8875.17 | 0.68 | 3.80 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27482.52 | 18580.38 | 8902.14 | 0.68 | 3.80 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27242.72 | 18418.26 | 8824.46 | 0.68 | 3.80 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 47508.14 | 32119.30 | 15388.84 | 0.68 | 3.73 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 24972.54 | 16883.43 | 8089.11 | 0.68 | 3.80 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 24846.87 | 16798.47 | 8048.40 | 0.68 | 3.80 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 24918.20 | 16846.70 | 8071.50 | 0.68 | 3.80 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 28302.20 | 19134.55 | 9167.65 | 0.68 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 50606.6 | 11.77 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 26469.5 | 34.79 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 26528.8 | 46.66 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 26609.4 | 58.47 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 26377.2 | 70.93 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 45998.8 | 51.83 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 24179.2 | 112.06 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 24057.5 | 124.57 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 24126.6 | 136.17 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 27403.1 | 131.83 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 48587.89 | 0.80 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25402.03 | 0.80 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25457.38 | 0.80 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25592.39 | 0.80 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25313.88 | 0.80 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 44910.44 | 0.80 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 23224.04 | 0.80 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 23108.53 | 0.80 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 23553.07 | 0.80 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 26288.55 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 2.10 | 2252.23 | 1070.05 | 1.00 | 1.31 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.10 | 1218.87 | 1107.16 | 1.00 | 1.38 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:40:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.10 | 1221.60 | 1107.16 | 1.00 | 1.38 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:30:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.11 | 1225.32 | 1107.16 | 1.00 | 1.38 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.10 | 1214.62 | 1107.16 | 1.00 | 1.38 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:30:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.91 | 2047.16 | 1070.05 | 1.00 | 1.32 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.01 | 1113.41 | 1107.16 | 1.00 | 1.40 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.00 | 1107.80 | 1107.16 | 1.00 | 1.40 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.00 | 1110.98 | 1107.16 | 1.00 | 1.40 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.14 | 1261.86 | 1107.16 | 1.00 | 1.37 | General | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 23880.16 | 28656.19 | 82.25 | 1.754 | 2.105 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | 23.89 | 23.88 | 0.01023 | 35.12 | 0.01713 | 0.411 | 0.00 |
SMSTORE1 | 12490.25 | 14988.30 | 86.04 | 0.917 | 1.101 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:40:00 | 23.89 | 23.88 | 0.01031 | 35.06 | 0.01713 | 0.206 | 0.00 |
SMSTORE2 | 12518.83 | 15022.59 | 86.24 | 0.919 | 1.103 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 23.89 | 23.88 | 0.01030 | 34.92 | 0.01713 | 0.206 | 0.00 |
SMSTORE3 | 12557.30 | 15068.76 | 86.51 | 0.922 | 1.107 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 23.89 | 23.88 | 0.01030 | 34.92 | 0.01713 | 0.206 | 0.00 |
SMSTORE4 | 12447.69 | 14937.23 | 85.75 | 0.914 | 1.097 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 23.89 | 23.88 | 0.01031 | 34.92 | 0.01713 | 0.206 | 0.00 |
LGSTORE2 | 21708.32 | 26049.98 | 74.77 | 1.594 | 1.913 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 23.89 | 23.88 | 0.01035 | 34.92 | 0.01713 | 0.411 | 0.00 |
SMSTORE5 | 11410.56 | 13692.68 | 78.61 | 0.838 | 1.006 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 23.89 | 23.88 | 0.01044 | 34.85 | 0.01713 | 0.206 | 0.00 |
SMSTORE6 | 11353.19 | 13623.82 | 78.21 | 0.834 | 1.001 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 23.89 | 23.88 | 0.01045 | 34.85 | 0.01713 | 0.206 | 0.00 |
SMSTORE7 | 11386.48 | 13663.78 | 78.44 | 0.836 | 1.003 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 23.89 | 23.88 | 0.01044 | 34.85 | 0.01713 | 0.206 | 0.00 |
SMSTORE8 | 12933.60 | 15520.32 | 89.10 | 0.950 | 1.140 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | 23.89 | 23.88 | 0.01028 | 34.78 | 0.01713 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 1900.08 | 2280.10 | 6.54 | 0.080 | 0.411 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01192 | 20.10 | 0.01480 | 0.411 | 0.00 |
SMSTORE1 | 913.76 | 1096.51 | 6.29 | 0.039 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01183 | 20.10 | 0.01480 | 0.206 | 0.00 |
SMSTORE2 | 991.50 | 1189.80 | 6.83 | 0.042 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.11 | 21.11 | 0.01267 | 20.10 | 0.01480 | 0.206 | 0.00 |
SMSTORE3 | 1026.97 | 1232.37 | 7.07 | 0.043 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.11 | 21.11 | 0.01262 | 20.10 | 0.01480 | 0.206 | 0.00 |
SMSTORE4 | 1173.78 | 1408.54 | 8.09 | 0.050 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.11 | 21.11 | 0.01243 | 20.10 | 0.01480 | 0.206 | 0.00 |
LGSTORE2 | 2210.83 | 2653.00 | 7.62 | 0.093 | 0.411 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01253 | 20.10 | 0.01480 | 0.411 | 0.00 |
SMSTORE5 | 1106.43 | 1327.71 | 7.62 | 0.047 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01265 | 20.10 | 0.01480 | 0.206 | 0.00 |
SMSTORE6 | 1097.98 | 1317.57 | 7.56 | 0.046 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01266 | 20.10 | 0.01480 | 0.206 | 0.00 |
SMSTORE7 | 1209.44 | 1451.33 | 8.33 | 0.051 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01251 | 20.10 | 0.01480 | 0.206 | 0.00 |
SMSTORE8 | 1240.53 | 1488.63 | 8.55 | 0.052 | 0.206 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 21.11 | 21.11 | 0.01291 | 20.10 | 0.01480 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 2.10 | 2.10 | 0.41 | 0.41 | 2.1048 | 2.1048 | 2.1048 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 1.10 | 1.10 | 0.21 | 0.21 | 1.1009 | 1.1009 | 1.1009 | 1.0000 | 1.0000 |
PSZ-AC_3:3 | 1.10 | 1.10 | 0.21 | 0.21 | 1.1034 | 1.1033 | 1.1034 | 1.0000 | 1.0000 |
PSZ-AC_4:4 | 1.11 | 1.11 | 0.21 | 0.21 | 1.1067 | 1.1067 | 1.1067 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 1.10 | 1.10 | 0.21 | 0.21 | 1.0971 | 1.0971 | 1.0971 | 1.0000 | 1.0000 |
PSZ-AC_6:6 | 1.91 | 1.91 | 0.41 | 0.41 | 1.9132 | 1.9132 | 1.9132 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 1.01 | 1.01 | 0.21 | 0.21 | 1.0056 | 1.0056 | 1.0056 | 0.9999 | 1.0000 |
PSZ-AC_8:8 | 1.00 | 1.00 | 0.21 | 0.21 | 1.0006 | 1.0005 | 1.0006 | 0.9999 | 1.0000 |
PSZ-AC_9:9 | 1.00 | 1.00 | 0.21 | 0.21 | 1.0035 | 1.0035 | 1.0035 | 1.0000 | 1.0000 |
PSZ-AC_10:10 | 1.14 | 1.14 | 0.21 | 0.21 | 1.1397 | 1.1397 | 1.1397 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 26133.575 | 0.000 | 2.104800 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | 26133.58 | 17071.62 | 2.104800 | 26.10 | 19.56 | 0.01158235 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 19.5483 | 23.88 | 0.01023197 | 55.2902 | 23872.32 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 48587.892 | 48587.892 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 48587.89 | 48587.89 | 2.104798 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 19.5484 | 21.11 | 0.01192411 | 76.0507 | 1052.35 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 13669.010 | 0.000 | 1.100900 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:40:00 | 13669.01 | 8899.60 | 1.100900 | 26.00 | 19.54 | 0.01159129 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 18.6871 | 23.88 | 0.01031290 | 55.7215 | 12482.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 25402.031 | 25402.031 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 25402.03 | 25402.03 | 1.100902 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 18.6871 | 21.11 | 0.01183147 | 75.4715 | 505.66 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 13699.625 | 0.000 | 1.103370 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:30:00 | 13699.62 | 8922.55 | 1.103370 | 26.00 | 19.53 | 0.01158761 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 18.6453 | 23.88 | 0.01030348 | 55.6713 | 12501.75 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 25457.380 | 25457.380 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:50:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:50:00 | 25457.38 | 25457.38 | 1.103368 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 18.6453 | 21.11 | 0.01266706 | 80.6935 | 717.37 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 13741.260 | 0.000 | 1.106720 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 13741.26 | 8955.57 | 1.106720 | 25.99 | 19.53 | 0.01158048 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 18.5889 | 23.88 | 0.01029903 | 55.6477 | 12537.95 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 25592.389 | 25592.389 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:20:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:20:00 | 25592.39 | 25592.39 | 1.106721 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 18.5888 | 21.11 | 0.01262383 | 80.4235 | 788.47 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 13621.360 | 0.000 | 1.097060 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:30:00 | 13621.36 | 8859.75 | 1.097060 | 26.01 | 19.55 | 0.01160206 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 18.7525 | 23.88 | 0.01031178 | 55.7154 | 12429.02 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 25313.878 | 25313.878 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:40:00 | 25313.88 | 25313.88 | 1.097064 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 18.7525 | 21.11 | 0.01242567 | 79.1853 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 23754.070 | 0.000 | 1.913150 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 23754.07 | 15196.71 | 1.913150 | 26.32 | 19.81 | 0.01182003 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 21.5066 | 23.88 | 0.01034561 | 55.8936 | 21669.78 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 44910.440 | 44910.440 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 44910.44 | 44910.44 | 1.913153 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 21.5066 | 21.11 | 0.01252665 | 79.8160 | 2210.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 12486.270 | 0.000 | 1.005640 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 12486.27 | 7961.06 | 1.005640 | 26.20 | 19.78 | 0.01182457 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 20.4573 | 23.88 | 0.01043801 | 56.3858 | 11388.55 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 23224.040 | 23224.040 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 13:10:00 | 23224.04 | 23224.04 | 1.005644 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 20.4572 | 21.11 | 0.01265067 | 80.5907 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 12423.435 | 0.000 | 1.000580 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 12423.43 | 7911.90 | 1.000580 | 26.21 | 19.79 | 0.01183777 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 20.5607 | 23.88 | 0.01044556 | 56.4259 | 11331.14 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 23108.528 | 23108.528 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 23108.53 | 23108.53 | 1.000584 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 20.5607 | 21.11 | 0.01266451 | 80.6771 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 12459.100 | 0.000 | 1.003460 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 12459.10 | 7938.98 | 1.003460 | 26.21 | 19.78 | 0.01183145 | 12.80 | 12.09 | 0.00850000 | 35.20 | 0.01713393 | 25.80 | 20.5017 | 23.88 | 0.01044119 | 56.4026 | 11358.67 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 23553.075 | 23553.075 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:40:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:40:00 | 23553.07 | 23553.07 | 1.003456 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 20.5018 | 21.11 | 0.01251428 | 79.7386 | 932.72 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 14151.100 | 0.000 | 1.139730 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | 14151.10 | 9258.00 | 1.139730 | 25.85 | 19.43 | 0.01151772 | 12.80 | 12.09 | 0.00850000 | 34.78 | 0.01713393 | 25.69 | 18.0505 | 23.88 | 0.01028067 | 55.5495 | 12933.60 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 26288.553 | 26288.553 | -999.0 | -999.0 | -999.000 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 26288.55 | 26288.55 | 1.139730 | 20.10 | 20.10 | 0.01479830 | 40.00 | 21.14 | 0.00800000 | 20.10 | 0.01479830 | 20.10 | 18.0505 | 21.11 | 0.01291276 | 82.2250 | 0.00 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 26133.575 | 0.000 | 2.104800 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.3710 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 15:10:00 | 26133.58 | 17071.62 | 1.0000 | 2.53332672 | 2.104800 | 26.10 | 19.56 | 0.01158235 | 55750.9 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26133.58 | 35.20 | 0.01713393 | 25.80 | 0.41145340 | 19.5483 | 23.88 | 0.01023286 | 23.88 | 0.01023197 | 55.2902 | 23872.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 48587.892 | 48587.892 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.104798 | 2.53332469 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 48587.89 | 48587.89 | 1.0000 | 2.53332469 | 2.104798 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 48587.89 | 20.10 | 0.01479830 | 20.10 | 0.41145340 | 19.5484 | 21.11 | 0.01155090 | 21.11 | 0.01192411 | 76.0507 | 1052.35 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 13669.010 | 0.000 | 1.100900 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.3876 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:40:00 | 13669.01 | 8899.60 | 1.0000 | 1.32503772 | 1.100900 | 26.00 | 19.54 | 0.01159129 | 55673.9 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13669.01 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 18.6871 | 23.88 | 0.01031659 | 23.88 | 0.01031290 | 55.7215 | 12482.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25402.031 | 25402.031 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.100902 | 1.32504011 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 25402.03 | 25402.03 | 1.0000 | 1.32504011 | 1.100902 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25402.03 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 18.6871 | 21.11 | 0.01170525 | 21.11 | 0.01183147 | 75.4715 | 505.66 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 13699.625 | 0.000 | 1.103370 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.3808 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:30:00 | 13699.62 | 8922.55 | 1.0000 | 1.32801059 | 1.103370 | 26.00 | 19.53 | 0.01158761 | 55661.2 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13699.62 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 18.6453 | 23.88 | 0.01031443 | 23.88 | 0.01030348 | 55.6713 | 12501.75 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25457.380 | 25457.380 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.103368 | 1.32800802 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:50:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:50:00 | 25457.38 | 25457.38 | 1.0000 | 1.32800802 | 1.103368 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25457.38 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 18.6453 | 21.11 | 0.01251995 | 21.11 | 0.01266706 | 80.6935 | 717.37 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 13741.260 | 0.000 | 1.106720 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.3675 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 13741.26 | 8955.57 | 1.0000 | 1.33204264 | 1.106720 | 25.99 | 19.53 | 0.01158048 | 55636.8 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13741.26 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 18.5889 | 23.88 | 0.01031019 | 23.88 | 0.01029903 | 55.6477 | 12537.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25592.389 | 25592.389 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.106721 | 1.33204388 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:20:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:20:00 | 25592.39 | 25592.39 | 1.0000 | 1.33204388 | 1.106721 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25592.39 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 18.5888 | 21.06 | 0.01253433 | 21.11 | 0.01262383 | 80.4235 | 788.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 13621.360 | 0.000 | 1.097060 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.4077 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:30:00 | 13621.36 | 8859.75 | 1.0000 | 1.32041591 | 1.097060 | 26.01 | 19.55 | 0.01160206 | 55710.8 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13621.36 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 18.7525 | 23.88 | 0.01032306 | 23.88 | 0.01031178 | 55.7154 | 12429.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25313.878 | 25313.878 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.097064 | 1.32042090 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 08:40:00 | 25313.88 | 25313.88 | 1.0000 | 1.32042090 | 1.097064 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25313.88 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 18.7525 | 21.11 | 0.00000000 | 21.11 | 0.01242567 | 79.1853 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 23754.070 | 0.000 | 1.913150 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.8128 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 23754.07 | 15196.71 | 1.0000 | 2.30265774 | 1.913150 | 26.32 | 19.81 | 0.01182003 | 56588.0 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23754.07 | 35.20 | 0.01713393 | 25.80 | 0.41145340 | 21.5066 | 23.88 | 0.01036095 | 23.88 | 0.01034561 | 55.8936 | 21669.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 44910.440 | 44910.440 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.913153 | 2.30266094 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 10:00:00 | 44910.44 | 44910.44 | 1.0000 | 2.30266094 | 1.913153 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 44910.44 | 20.10 | 0.01479830 | 20.10 | 0.41145340 | 21.5066 | 20.73 | 0.01252665 | 21.11 | 0.01252665 | 79.8160 | 2210.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 12486.270 | 0.000 | 1.005640 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.8213 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 12486.27 | 7961.06 | 1.0000 | 1.21038326 | 1.005640 | 26.20 | 19.78 | 0.01182457 | 56477.4 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12486.27 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 20.4573 | 23.88 | 0.01045594 | 23.88 | 0.01043801 | 56.3858 | 11388.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 23224.040 | 23224.040 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.005644 | 1.21038806 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 13:10:00 | 23224.04 | 23224.04 | 1.0000 | 1.21038806 | 1.005644 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23224.04 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 20.4572 | 21.11 | 0.00000000 | 21.11 | 0.01265067 | 80.5907 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 12423.435 | 0.000 | 1.000580 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.8458 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:20:00 | 12423.43 | 7911.90 | 1.0000 | 1.20429307 | 1.000580 | 26.21 | 19.79 | 0.01183777 | 56523.2 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12423.43 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 20.5607 | 23.88 | 0.01046384 | 23.88 | 0.01044556 | 56.4259 | 11331.14 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 23108.528 | 23108.528 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.000584 | 1.20429730 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 23108.53 | 23108.53 | 1.0000 | 1.20429730 | 1.000584 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23108.53 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 20.5607 | 21.11 | 0.00000000 | 21.11 | 0.01266451 | 80.6771 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 12459.100 | 0.000 | 1.003460 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.8341 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 14:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:10:00 | 12459.10 | 7938.98 | 1.0000 | 1.20775942 | 1.003460 | 26.21 | 19.78 | 0.01183145 | 56501.3 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12459.10 | 35.20 | 0.01713393 | 25.80 | 0.20572670 | 20.5017 | 23.88 | 0.01046007 | 23.88 | 0.01044119 | 56.4026 | 11358.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 23553.075 | 23553.075 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.003456 | 1.20775432 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:40:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 09:40:00 | 23553.07 | 23553.07 | 1.0000 | 1.20775432 | 1.003456 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23553.07 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 20.5018 | 20.72 | 0.01256037 | 21.11 | 0.01251428 | 79.7386 | 932.72 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14151.100 | 0.000 | 1.139730 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1026.2509 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN CLG .4% CONDNS DB=>MWB | 4/21 13:00:00 | 14151.10 | 9258.00 | 1.0000 | 1.37177331 | 1.139730 | 25.85 | 19.43 | 0.01151772 | 55334.6 | 12.80 | 12.09 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14151.10 | 34.78 | 0.01713393 | 25.69 | 0.20572670 | 18.0505 | 23.89 | 0.01028067 | 23.88 | 0.01028067 | 55.5495 | 12933.60 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26288.553 | 26288.553 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.139730 | 1.37177281 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | HO.CHI.MINH.CITY-TAN.SON.NHAT.AP_VNM ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 26288.55 | 26288.55 | 1.0000 | 1.37177281 | 1.139730 | 20.10 | 20.10 | 0.01479830 | 57759.9 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26288.55 | 20.10 | 0.01479830 | 20.10 | 0.20572670 | 18.0505 | 21.11 | 0.00000000 | 21.11 | 0.01291276 | 82.2250 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 5840.00 | 1719.50 | 1719.50 |
SMSTORE1 | 5838.33 | 1455.67 | 1455.67 |
SMSTORE2 | 4395.00 | 1826.17 | 1826.17 |
SMSTORE3 | 4395.00 | 1809.00 | 1809.00 |
SMSTORE4 | 4395.00 | 1897.50 | 1897.50 |
LGSTORE2 | 4030.00 | 2093.67 | 2093.67 |
SMSTORE5 | 4030.00 | 2158.50 | 2158.50 |
SMSTORE6 | 4030.00 | 2185.50 | 2185.50 |
SMSTORE7 | 4030.00 | 2172.83 | 2172.83 |
SMSTORE8 | 4030.00 | 1609.33 | 1609.33 |
Facility | 5943.00 | 2686.33 | 2686.33 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 0.00 | 4.17 | 0.00 | 3.00 |
SMSTORE1 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 0.00 | 7.67 | 0.00 | 0.00 |
SMSTORE3 | 0.00 | 8.33 | 0.00 | 0.00 |
SMSTORE4 | 0.00 | 6.83 | 0.00 | 0.00 |
LGSTORE2 | 0.00 | 10.17 | 0.00 | 0.00 |
SMSTORE5 | 0.00 | 9.17 | 0.00 | 0.00 |
SMSTORE6 | 0.00 | 8.83 | 0.00 | 0.00 |
SMSTORE7 | 0.00 | 7.83 | 0.00 | 0.00 |
SMSTORE8 | 0.00 | 11.67 | 0.00 | 0.00 |
Facility | 0.00 | 22.17 | 0.00 | 3.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.02 | 30.00 | 1805.20 | 0.849 | 0.335 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.722 | 0.374 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.850 | 0.492 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.850 | 0.491 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.851 | 0.492 | 0.000 | 0.000 |
LGSTORE2 | 13.24 | 30.00 | 1805.20 | 0.851 | 0.460 | 0.000 | 0.000 |
SMSTORE5 | 6.62 | 15.00 | 902.60 | 0.851 | 0.524 | 0.000 | 0.000 |
SMSTORE6 | 6.62 | 15.00 | 902.60 | 0.851 | 0.524 | 0.000 | 0.000 |
SMSTORE7 | 6.62 | 15.00 | 902.60 | 0.851 | 0.524 | 0.000 | 0.000 |
SMSTORE8 | 6.62 | 15.00 | 902.60 | 0.850 | 0.538 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.02 | 30.00 | 1805.20 | 0.832 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.170 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.831 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.831 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.831 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.24 | 30.00 | 1805.20 | 0.833 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.62 | 15.00 | 902.60 | 0.833 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.62 | 15.00 | 902.60 | 0.833 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.62 | 15.00 | 902.60 | 0.833 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.62 | 15.00 | 902.60 | 0.833 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
Electricity:Building | 579.04 | 891.83 | 01-JAN-00:20 | 37073.46 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 132.39 | 148.64 | 01-JAN-00:20 | 6930.31 | 01-JAN-10:10 |
InteriorLights:Electricity | 450.89 | 450.00 | 01-JAN-00:20 | 29013.96 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 106.14 | 75.00 | 01-JAN-00:20 | 5587.06 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 450.89 | 450.00 | 01-JAN-00:20 | 29013.96 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 75.15 | 74.32 | 01-JAN-00:20 | 3939.90 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 62.02 | 37.50 | 01-JAN-00:20 | 3268.27 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 54.53 | 74.32 | 01-JAN-00:10 | 3678.60 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 44.11 | 37.50 | 01-JAN-00:10 | 3006.97 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 54.53 | 74.32 | 01-JAN-00:10 | 3678.60 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 44.11 | 37.50 | 01-JAN-00:10 | 3006.97 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 54.53 | 74.32 | 01-JAN-00:10 | 3678.60 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 44.11 | 37.50 | 01-JAN-00:10 | 3006.97 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 69.31 | 148.64 | 01-JAN-00:10 | 5055.82 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 50.13 | 75.00 | 01-JAN-00:10 | 3712.57 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 34.65 | 74.32 | 01-JAN-00:10 | 2527.91 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 25.07 | 37.50 | 01-JAN-00:10 | 1856.29 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.15 | 441.83 | 01-JAN-00:10 | 8059.50 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.25 | 73.64 | 01-JAN-00:10 | 1343.25 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.15 | 441.83 | 01-JAN-00:10 | 8059.50 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.12 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.17 | 73.64 | 01-JAN-00:10 | 1343.25 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
Electricity:Plant | 57.52 | 1211.00 | 05-JAN-07:10 | 11769.75 | 02-JAN-13:20 |
WaterSystems:Electricity | 57.52 | 1211.00 | 05-JAN-07:10 | 11769.75 | 02-JAN-13:20 |
Water Heater:WaterSystems:Electricity | 57.52 | 1211.00 | 05-JAN-07:10 | 11769.75 | 02-JAN-13:20 |
ElectricityPurchased:Facility | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
ElectricityPurchased:Plant | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
Cogeneration:ElectricityPurchased | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
ElectricityNet:Plant | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
Cogeneration:ElectricityNet | 1511.69 | 2102.83 | 01-JAN-06:20 | 136761.97 | 13-JUN-13:50 |
Electricity:HVAC | 815.65 | 0.00 | 01-JAN-00:10 | 91686.39 | 16-JUN-13:00 |
Fans:Electricity | 117.09 | 0.00 | 01-JAN-00:10 | 12687.72 | 16-JUN-13:00 |
General:Fans:Electricity | 117.09 | 0.00 | 01-JAN-00:10 | 12687.72 | 16-JUN-13:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 698.55 | 0.00 | 01-JAN-00:10 | 78998.67 | 16-JUN-13:00 |
ExteriorLights:Electricity | 59.48 | 0.00 | 01-JAN-06:20 | 5459.01 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 59.48 | 0.00 | 01-JAN-06:20 | 5459.01 | 01-JAN-06:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:Gas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 4113.21 | 0.00 | 01-JAN-00:10 | 424968.17 | 16-JUN-13:00 |
EnergyTransfer:Building | 1172.92 | 0.00 | 01-JAN-00:10 | 120786.73 | 06-MAY-13:00 |
EnergyTransfer:Zone:LGSTORE1 | 240.25 | 0.00 | 01-JAN-00:10 | 20300.88 | 06-MAY-13:00 |
Heating:EnergyTransfer | 6.17 | 0.00 | 01-JAN-00:10 | 21302.71 | 29-MAY-16:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 0.28 | 0.00 | 01-JAN-00:10 | 1909.89 | 25-FEB-08:20 |
Cooling:EnergyTransfer | 1166.75 | 0.00 | 01-JAN-00:10 | 120786.73 | 06-MAY-13:00 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 239.97 | 0.00 | 01-JAN-00:10 | 20300.88 | 06-MAY-13:00 |
EnergyTransfer:Zone:SMSTORE1 | 124.66 | 0.00 | 01-JAN-00:10 | 10524.64 | 06-MAY-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 0.14 | 0.00 | 01-JAN-00:10 | 835.55 | 29-SEP-07:20 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 124.51 | 0.00 | 01-JAN-00:10 | 10524.64 | 06-MAY-13:00 |
EnergyTransfer:Zone:SMSTORE2 | 98.45 | 0.00 | 01-JAN-00:10 | 10546.68 | 06-MAY-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 0.97 | 0.00 | 01-JAN-00:10 | 2354.57 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 97.48 | 0.00 | 01-JAN-00:10 | 10546.68 | 06-MAY-13:00 |
EnergyTransfer:Zone:SMSTORE3 | 98.86 | 0.00 | 01-JAN-00:10 | 10571.24 | 06-MAY-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 0.97 | 0.00 | 01-JAN-00:10 | 2352.72 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 97.89 | 0.00 | 01-JAN-00:10 | 10571.24 | 06-MAY-13:00 |
EnergyTransfer:Zone:SMSTORE4 | 96.91 | 0.00 | 01-JAN-00:10 | 10443.10 | 06-MAY-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 0.98 | 0.00 | 01-JAN-00:10 | 2358.38 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 95.93 | 0.00 | 01-JAN-00:10 | 10443.10 | 06-MAY-13:00 |
EnergyTransfer:Zone:LGSTORE2 | 162.02 | 0.00 | 01-JAN-00:10 | 18162.78 | 06-MAY-13:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 0.95 | 0.00 | 01-JAN-00:10 | 4761.38 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 161.07 | 0.00 | 01-JAN-00:10 | 18162.78 | 06-MAY-13:10 |
EnergyTransfer:Zone:SMSTORE5 | 84.45 | 0.00 | 01-JAN-00:10 | 9626.72 | 06-MAY-13:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 0.48 | 0.00 | 01-JAN-00:10 | 2387.43 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 83.97 | 0.00 | 01-JAN-00:10 | 9626.72 | 06-MAY-13:10 |
EnergyTransfer:Zone:SMSTORE6 | 83.86 | 0.00 | 01-JAN-00:10 | 9584.92 | 06-MAY-13:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 0.48 | 0.00 | 01-JAN-00:10 | 2389.23 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 83.38 | 0.00 | 01-JAN-00:10 | 9584.92 | 06-MAY-13:10 |
EnergyTransfer:Zone:SMSTORE7 | 84.10 | 0.00 | 01-JAN-00:10 | 9662.83 | 06-MAY-13:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 0.49 | 0.00 | 01-JAN-00:10 | 2386.68 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 83.62 | 0.00 | 01-JAN-00:10 | 9662.83 | 06-MAY-13:10 |
EnergyTransfer:Zone:SMSTORE8 | 99.36 | 0.00 | 01-JAN-00:10 | 11427.35 | 06-MAY-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 0.44 | 0.00 | 01-JAN-00:10 | 2312.32 | 29-MAY-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 98.93 | 0.00 | 01-JAN-00:10 | 11427.35 | 06-MAY-13:00 |
EnergyTransfer:HVAC | 2940.29 | 0.00 | 01-JAN-00:10 | 310386.51 | 16-JUN-13:00 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
CoolingCoils:EnergyTransfer | 2940.29 | 0.00 | 01-JAN-00:10 | 310386.51 | 16-JUN-13:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 0.277 | -239.970 | 0.000 | 0.000 | 12.382 | 106.140 | 26.249 | 13.836 | 0.000 | 28.378 | 54.046 | 0.000 | -1.119 | 0.000 | -0.219 | -0.000 |
SMSTORE1 | 0.000 | 0.000 | 0.145 | -124.508 | 0.000 | 0.000 | 6.191 | 62.022 | 13.125 | 6.984 | 0.000 | 15.902 | 20.758 | 0.000 | -0.549 | 0.000 | -0.069 | -0.002 |
SMSTORE2 | 0.000 | 0.000 | 0.968 | -97.476 | 0.000 | 0.000 | 3.717 | 44.110 | 10.421 | 6.875 | 0.000 | 15.623 | 16.598 | 0.000 | -0.720 | 0.000 | -0.117 | -0.000 |
SMSTORE3 | 0.000 | 0.000 | 0.966 | -97.889 | 0.000 | 0.000 | 3.717 | 44.110 | 10.421 | 6.870 | 0.000 | 15.618 | 17.042 | 0.000 | -0.735 | 0.000 | -0.120 | -0.000 |
SMSTORE4 | 0.000 | 0.000 | 0.982 | -95.929 | 0.000 | 0.000 | 3.717 | 44.110 | 10.421 | 6.882 | 0.000 | 15.627 | 15.011 | 0.000 | -0.709 | 0.000 | -0.111 | -0.000 |
LGSTORE2 | 0.000 | 0.000 | 0.950 | -161.069 | 0.000 | 0.000 | 12.760 | 50.132 | 19.173 | 13.729 | 0.000 | 27.447 | 38.337 | 0.000 | -1.259 | 0.000 | -0.200 | -0.001 |
SMSTORE5 | 0.000 | 0.000 | 0.479 | -83.966 | 0.000 | 0.000 | 6.380 | 25.066 | 9.586 | 6.901 | 0.000 | 15.654 | 20.591 | 0.000 | -0.595 | 0.000 | -0.097 | -0.000 |
SMSTORE6 | 0.000 | 0.000 | 0.482 | -83.376 | 0.000 | 0.000 | 6.380 | 25.066 | 9.586 | 6.908 | 0.000 | 15.656 | 19.981 | 0.000 | -0.589 | 0.000 | -0.096 | -0.000 |
SMSTORE7 | 0.000 | 0.000 | 0.485 | -83.613 | 0.000 | 0.000 | 6.380 | 25.066 | 9.586 | 6.900 | 0.000 | 15.657 | 20.224 | 0.000 | -0.591 | 0.000 | -0.094 | -0.000 |
SMSTORE8 | 0.000 | 0.000 | 0.436 | -98.923 | 0.000 | 0.000 | 6.380 | 25.066 | 9.586 | 6.781 | 0.000 | 16.089 | 35.448 | 0.000 | -0.643 | 0.000 | -0.220 | -0.001 |
Total Facility | 0.000 | 0.000 | 6.171 | -1166.719 | 0.000 | 0.000 | 68.003 | 450.890 | 128.154 | 82.666 | 0.000 | 181.651 | 258.036 | 0.000 | -7.509 | 0.000 | -1.343 | -0.004 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 24-JAN-08:62 | 0.00 | 0.00 | 0.00 | -34621.50 | 0.00 | 0.00 | 95.60 | 75.00 | 74.62 | 716.94 | 0.00 | 0.00 | 33982.02 | 0.00 | -0.00 | 0.00 | -322.68 | 0.00 |
SMSTORE1 | 24-JAN-08:62 | 0.00 | 0.00 | 0.00 | -19610.95 | 0.00 | 0.00 | 47.07 | 37.50 | 37.31 | 354.41 | 0.00 | 0.00 | 19313.97 | 0.00 | -0.00 | 0.00 | -179.31 | 0.00 |
SMSTORE2 | 25-FEB-07:02 | 0.00 | 0.00 | 0.00 | -17382.33 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 81.77 | 0.00 | 0.00 | 17226.95 | 0.00 | -0.00 | 0.00 | -0.71 | 0.00 |
SMSTORE3 | 25-FEB-07:02 | 0.00 | 0.00 | 0.00 | -17462.09 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 81.10 | 0.00 | 0.00 | 17307.39 | 0.00 | -0.00 | 0.00 | -0.72 | 0.00 |
SMSTORE4 | 25-FEB-07:02 | 0.00 | 0.00 | 0.00 | -17190.89 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 83.10 | 0.00 | 0.00 | 17034.16 | 0.00 | -0.00 | 0.00 | -0.68 | 0.00 |
LGSTORE2 | 23-FEB-08:62 | 0.00 | 0.00 | 0.00 | -30519.56 | 0.00 | 0.00 | 0.00 | 75.00 | 73.64 | 611.21 | 0.00 | 0.00 | 29882.42 | 0.00 | -0.00 | 0.00 | -122.71 | 0.00 |
SMSTORE5 | 23-FEB-08:62 | 0.00 | 0.00 | 0.00 | -15947.88 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 307.50 | 0.00 | 0.00 | 15630.88 | 0.00 | -0.00 | 0.00 | -64.82 | 0.00 |
SMSTORE6 | 23-FEB-08:62 | 0.00 | 0.00 | 0.00 | -15835.99 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 308.10 | 0.00 | 0.00 | 15517.50 | 0.00 | -0.00 | 0.00 | -63.93 | 0.00 |
SMSTORE7 | 23-FEB-08:62 | 0.00 | 0.00 | 0.00 | -15855.81 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 308.33 | 0.00 | 0.00 | 15535.43 | 0.00 | -0.00 | 0.00 | -62.27 | 0.00 |
SMSTORE8 | 23-FEB-08:62 | 0.00 | 0.00 | 0.00 | -17914.63 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 303.87 | 0.00 | 0.00 | 17604.96 | 0.00 | -0.00 | 0.00 | -68.52 | 0.00 |
Total Facility | 23-FEB-08:62 | 0.00 | 0.00 | 0.00 | -157605.51 | 0.00 | 0.00 | 293.07 | 450.00 | 1452.23 | 3715.90 | 0.00 | 0.00 | 152341.01 | 0.00 | 0.00 | 0.00 | -646.70 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 28-MAY-07:07 | 0.00 | 0.00 | 5264.35 | 0.00 | 0.00 | 0.00 | 86.73 | 75.00 | 74.62 | 529.35 | 0.00 | 578.73 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6608.78 |
SMSTORE1 | 28-MAY-07:06 | 0.00 | 0.00 | 2797.28 | 0.00 | 0.00 | 0.00 | 43.42 | 37.50 | 37.31 | 265.77 | 0.00 | 323.98 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3505.26 |
SMSTORE2 | 29-MAY-16:01 | 0.00 | 0.00 | 2813.89 | 0.00 | 0.00 | 0.00 | 52.55 | 1582.62 | 373.13 | 371.21 | 0.00 | 2606.21 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7799.60 |
SMSTORE3 | 29-MAY-16:01 | 0.00 | 0.00 | 2813.08 | 0.00 | 0.00 | 0.00 | 52.55 | 1582.62 | 373.13 | 370.98 | 0.00 | 2605.90 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7798.25 |
SMSTORE4 | 29-MAY-16:01 | 0.00 | 0.00 | 2815.39 | 0.00 | 0.00 | 0.00 | 52.55 | 1582.62 | 373.13 | 371.30 | 0.00 | 2606.79 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7801.77 |
LGSTORE2 | 29-MAY-16:01 | 0.00 | 0.00 | 5637.40 | 0.00 | 0.00 | 0.00 | 231.21 | 1953.98 | 746.25 | 740.25 | 0.00 | 4580.19 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -13889.29 |
SMSTORE5 | 29-MAY-16:01 | 0.00 | 0.00 | 2825.13 | 0.00 | 0.00 | 0.00 | 115.61 | 976.99 | 373.13 | 373.29 | 0.00 | 2612.35 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7276.50 |
SMSTORE6 | 29-MAY-16:01 | 0.00 | 0.00 | 2825.70 | 0.00 | 0.00 | 0.00 | 115.61 | 976.99 | 373.13 | 373.53 | 0.00 | 2612.70 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7277.65 |
SMSTORE7 | 29-MAY-16:01 | 0.00 | 0.00 | 2824.41 | 0.00 | 0.00 | 0.00 | 115.61 | 976.99 | 373.13 | 372.88 | 0.00 | 2612.20 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7275.22 |
SMSTORE8 | 29-MAY-16:01 | 0.00 | 0.00 | 2793.10 | 0.00 | 0.00 | 0.00 | 115.61 | 976.99 | 373.13 | 364.59 | 0.00 | 2614.54 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7237.95 |
Total Facility | 29-MAY-16:01 | -27475.66 | 27475.66 | 25348.10 | -27475.66 | 0.00 | 0.00 | 2743.13 | 19465.13 | 5373.00 | 4468.52 | 0.00 | 30346.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -60269.02 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.1048 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 2.1048 | 0.1955 | 1.0000 | 0.4115 | 0.1955 | ||
PSZ-AC_2:2 | 1.1009 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1009 | 0.1869 | 1.0000 | 0.2057 | 0.1869 | ||
PSZ-AC_3:3 | 1.1033 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1034 | 0.1865 | 1.0000 | 0.2057 | 0.1865 | ||
PSZ-AC_4:4 | 1.1067 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1067 | 0.1859 | 1.0000 | 0.2057 | 0.1859 | ||
PSZ-AC_5:5 | 1.0971 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0971 | 0.1875 | 1.0000 | 0.2057 | 0.1875 | ||
PSZ-AC_6:6 | 1.9132 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.9132 | 0.2151 | 1.0000 | 0.4115 | 0.2151 | ||
PSZ-AC_7:7 | 1.0056 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0056 | 0.2046 | 1.0000 | 0.2057 | 0.2046 | ||
PSZ-AC_8:8 | 1.0005 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0006 | 0.2056 | 1.0000 | 0.2057 | 0.2056 | ||
PSZ-AC_9:9 | 1.0035 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0035 | 0.2050 | 1.0000 | 0.2057 | 0.2050 | ||
PSZ-AC_10:10 | 1.1397 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1397 | 0.1805 | 1.0000 | 0.2057 | 0.1805 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 2.1048 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 2.1048 | 1.0000 | 1.0000 | 0.4115 | 0.1955 | ||
PSZ-AC_2:2 | 1.1009 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1009 | 1.0000 | 1.0000 | 0.2057 | 0.1869 | ||
PSZ-AC_3:3 | 1.1033 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1033 | 1.0000 | 1.0000 | 0.2057 | 0.1865 | ||
PSZ-AC_4:4 | 1.1067 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1067 | 1.0000 | 1.0000 | 0.2057 | 0.1859 | ||
PSZ-AC_5:5 | 1.0971 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0971 | 1.0000 | 1.0000 | 0.2057 | 0.1875 | ||
PSZ-AC_6:6 | 1.9132 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.9132 | 1.0000 | 1.0000 | 0.4115 | 0.2151 | ||
PSZ-AC_7:7 | 1.0056 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0056 | 1.0000 | 1.0000 | 0.2057 | 0.2046 | ||
PSZ-AC_8:8 | 1.0005 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0005 | 1.0000 | 1.0000 | 0.2057 | 0.2056 | ||
PSZ-AC_9:9 | 1.0035 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0035 | 1.0000 | 1.0000 | 0.2057 | 0.2050 | ||
PSZ-AC_10:10 | 1.1397 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.1397 | 1.0000 | 1.0000 | 0.2057 | 0.1805 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 2.1048 | 2.1048 | 2.1048 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.1009 | 1.1009 | 1.1009 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.1033 | 1.1033 | 1.1033 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.1067 | 1.1067 | 1.1067 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.0971 | 1.0971 | 1.0971 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.9132 | 1.9132 | 1.9132 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 1.0056 | 1.0056 | 1.0056 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 1.0005 | 1.0005 | 1.0005 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 1.0035 | 1.0035 | 1.0035 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.1397 | 1.1397 | 1.1397 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.1048 | 2.1048 | 2.1048 | 2.1048 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.1009 | 1.1009 | 1.1009 | 1.1009 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.1033 | 1.1034 | 1.1033 | 1.1033 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.1067 | 1.1067 | 1.1067 | 1.1067 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0971 | 1.0971 | 1.0971 | 1.0971 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.9132 | 1.9132 | 1.9132 | 1.9132 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 1.0056 | 1.0056 | 1.0056 | 1.0056 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 1.0005 | 1.0006 | 1.0005 | 1.0005 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 1.0035 | 1.0035 | 1.0035 | 1.0035 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.1397 | 1.1397 | 1.1397 | 1.1397 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 2.1048 | 2.1048 | 2.1048 | 0.4115 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 1.1009 | 1.1009 | 1.1009 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.1033 | 1.1033 | 1.1033 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 1.1067 | 1.1067 | 1.1067 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 1.0971 | 1.0971 | 1.0971 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.9132 | 1.9132 | 1.9132 | 0.4115 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 1.0056 | 1.0056 | 1.0056 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 1.0005 | 1.0005 | 1.0005 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 1.0035 | 1.0035 | 1.0035 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 1.1397 | 1.1397 | 1.1397 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 2.1048 | 2.1048 | 2.1048 | 2.1048 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 1.1009 | 1.1009 | 1.1009 | 1.1009 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.1033 | 1.1033 | 1.1033 | 1.1033 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 1.1067 | 1.1067 | 1.1067 | 1.1067 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 1.0971 | 1.0971 | 1.0971 | 1.0971 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.9132 | 1.9132 | 1.9132 | 1.9132 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 1.0056 | 1.0056 | 1.0056 | 1.0056 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 1.0005 | 1.0005 | 1.0005 | 1.0005 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 1.0035 | 1.0035 | 1.0035 | 1.0035 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 1.1397 | 1.1397 | 1.1397 | 1.1397 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:51
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Ho Chi Minh City-Tan Son Nhat Intl AP - VNM IWEC2 WMO#=489000 |
Total gross floor area [m2] | 2090.32 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 3.00 |
Number of hours not met | 3.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 698.55 | 78998.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 450.89 | 29013.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 59.48 | 5459.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.15 | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 117.09 | 12687.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 57.52 | 11769.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.15 | 1511.69 |
Natural Gas | 0.00 | 0.00 |
Additional | 0.00 | 0.00 |
Total | 128.15 | 1511.69 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 215.70 |
Space Heating | 0.00 |
Space Cooling | 334.19 |
Fans (All) | 56.02 |
Service Water Heating | 27.52 |
Receptacle Equipment | 61.31 |
Miscellaneous (All) | 723.19 |
Subtotal | 723.19 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 0.00 |
Subtotal | 0.00 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 29.83 |
Space Heating | 0.00 |
Space Cooling | 46.21 |
Fans (All) | 7.75 |
Service Water Heating | 3.81 |
Receptacle Equipment | 8.48 |
Miscellaneous | 3.93 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5122. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4868. | 8760. |
TYPE2_EQUIP_SCH | 3893. | 8760. |
TYPE3_EQUIP_SCH | 3584. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2016
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 0A
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY VNM_HOCHIMINH_TANSONHOA
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.198234E+11 | 34631.92 | 24-JAN-08:62 | 19.83 | 17.92 | 0.751710E+09 | 898.98 | 29-JAN-18:00 | 29.00 | 23.93 |
February | 0.187707E+11 | 33974.89 | 21-FEB-08:61 | 26.33 | 21.22 | 0.678607E+09 | 898.93 | 26-FEB-17:30 | 29.90 | 23.54 |
March | 0.212678E+11 | 31546.85 | 03-MAR-08:62 | 26.17 | 20.15 | 0.744968E+09 | 898.94 | 26-MAR-17:00 | 30.00 | 24.82 |
April | 0.210481E+11 | 28065.38 | 27-APR-07:01 | 27.08 | 24.31 | 0.726344E+09 | 898.96 | 23-APR-17:40 | 31.00 | 24.90 |
May | 0.216138E+11 | 26109.48 | 09-MAY-07:01 | 24.50 | 24.40 | 0.747383E+09 | 898.93 | 28-MAY-16:19 | 28.07 | 26.23 |
June | 0.215843E+11 | 27123.11 | 25-JUN-07:01 | 25.75 | 24.65 | 0.722006E+09 | 898.91 | 04-JUN-16:30 | 32.10 | 27.83 |
July | 0.201492E+11 | 30637.92 | 09-JUL-07:01 | 26.50 | 23.81 | 0.753585E+09 | 898.94 | 02-JUL-17:00 | 28.00 | 23.67 |
August | 0.196224E+11 | 27474.76 | 24-AUG-07:02 | 25.75 | 25.32 | 0.743052E+09 | 898.91 | 27-AUG-16:30 | 32.50 | 26.16 |
September | 0.194521E+11 | 28152.28 | 09-SEP-07:02 | 25.08 | 24.00 | 0.728199E+09 | 898.92 | 17-SEP-17:00 | 27.00 | 25.53 |
October | 0.187717E+11 | 27917.03 | 09-OCT-07:01 | 25.50 | 24.67 | 0.751683E+09 | 898.93 | 29-OCT-17:00 | 25.50 | 24.34 |
November | 0.185507E+11 | 32537.92 | 25-NOV-08:62 | 22.25 | 19.44 | 0.726902E+09 | 898.93 | 05-NOV-17:00 | 27.50 | 24.58 |
December | 0.193189E+11 | 32227.72 | 27-DEC-08:62 | 23.50 | 19.74 | 0.755464E+09 | 898.98 | 31-DEC-18:00 | 27.40 | 25.07 |
Annual Sum or Average | 0.239973E+12 | 0.882990E+10 | ||||||||
Minimum of Months | 0.185507E+11 | 26109.48 | 19.83 | 17.92 | 0.678607E+09 | 898.91 | 25.50 | 23.54 | ||
Maximum of Months | 0.216138E+11 | 34631.92 | 27.08 | 25.32 | 0.755464E+09 | 898.98 | 32.50 | 27.83 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.103646E+11 | 19614.43 | 24-JAN-08:62 | 19.83 | 17.92 | 0.375852E+09 | 449.48 | 08-JAN-17:30 | 29.40 | 23.96 |
February | 0.973153E+10 | 19451.66 | 24-FEB-08:62 | 23.33 | 18.56 | 0.339300E+09 | 449.47 | 26-FEB-17:30 | 29.90 | 23.54 |
March | 0.109318E+11 | 18408.05 | 03-MAR-08:62 | 26.17 | 20.15 | 0.372477E+09 | 449.46 | 19-MAR-16:30 | 33.35 | 24.64 |
April | 0.108075E+11 | 16657.70 | 23-APR-07:02 | 25.42 | 24.10 | 0.363163E+09 | 449.46 | 23-APR-16:30 | 32.60 | 24.72 |
May | 0.111798E+11 | 16038.97 | 09-MAY-07:01 | 24.50 | 24.40 | 0.373681E+09 | 449.45 | 14-MAY-16:30 | 33.40 | 27.22 |
June | 0.110965E+11 | 16929.83 | 25-JUN-07:01 | 25.75 | 24.65 | 0.360992E+09 | 449.45 | 04-JUN-16:30 | 32.10 | 27.83 |
July | 0.104318E+11 | 17969.77 | 08-JUL-07:02 | 25.08 | 22.66 | 0.376784E+09 | 449.46 | 02-JUL-16:30 | 28.40 | 23.64 |
August | 0.101877E+11 | 16581.88 | 24-AUG-07:02 | 25.75 | 25.32 | 0.371516E+09 | 449.45 | 27-AUG-16:30 | 32.50 | 26.16 |
September | 0.100760E+11 | 16987.55 | 10-SEP-07:01 | 26.50 | 25.49 | 0.364090E+09 | 449.45 | 04-SEP-16:30 | 32.50 | 26.80 |
October | 0.986117E+10 | 17020.30 | 08-OCT-07:02 | 25.75 | 24.25 | 0.375833E+09 | 449.45 | 08-OCT-16:30 | 29.55 | 25.00 |
November | 0.971456E+10 | 18946.90 | 25-NOV-08:62 | 22.25 | 19.44 | 0.363444E+09 | 449.45 | 05-NOV-16:30 | 29.10 | 24.59 |
December | 0.101275E+11 | 18748.71 | 27-DEC-08:62 | 23.50 | 19.74 | 0.377727E+09 | 449.47 | 25-DEC-17:19 | 28.33 | 24.29 |
Annual Sum or Average | 0.124510E+12 | 0.441486E+10 | ||||||||
Minimum of Months | 0.971456E+10 | 16038.97 | 19.83 | 17.92 | 0.339300E+09 | 449.45 | 28.33 | 23.54 | ||
Maximum of Months | 0.111798E+11 | 19614.43 | 26.50 | 25.49 | 0.377727E+09 | 449.48 | 33.40 | 27.83 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.808087E+10 | 16705.87 | 24-JAN-07:02 | 19.50 | 17.56 | 0.224376E+09 | 449.42 | 28-JAN-13:09 | 31.75 | 21.64 |
February | 0.765275E+10 | 17388.08 | 25-FEB-07:02 | 22.83 | 19.09 | 0.203840E+09 | 449.43 | 25-FEB-13:20 | 31.80 | 22.27 |
March | 0.871187E+10 | 15793.42 | 04-MAR-07:02 | 24.83 | 20.47 | 0.230368E+09 | 449.45 | 04-MAR-13:09 | 33.25 | 22.11 |
April | 0.849067E+10 | 14060.03 | 27-APR-06:01 | 26.15 | 23.95 | 0.219360E+09 | 449.31 | 22-APR-12:09 | 32.68 | 25.44 |
May | 0.886166E+10 | 12809.65 | 11-MAY-06:01 | 24.37 | 24.37 | 0.227431E+09 | 449.31 | 06-MAY-12:09 | 37.10 | 26.02 |
June | 0.886070E+10 | 12739.89 | 27-JUN-06:02 | 23.42 | 23.23 | 0.222565E+09 | 449.26 | 10-JUN-12:09 | 33.17 | 27.84 |
July | 0.801222E+10 | 14270.06 | 06-JUL-06:01 | 25.22 | 23.03 | 0.224162E+09 | 449.33 | 22-JUL-12:09 | 30.43 | 24.41 |
August | 0.802582E+10 | 13037.98 | 24-AUG-06:02 | 24.25 | 24.17 | 0.230270E+09 | 449.32 | 19-AUG-12:09 | 29.12 | 25.92 |
September | 0.780206E+10 | 12722.16 | 28-SEP-06:01 | 25.17 | 24.30 | 0.219226E+09 | 449.38 | 16-SEP-12:00 | 24.40 | 24.15 |
October | 0.760462E+10 | 12738.09 | 11-OCT-06:02 | 24.10 | 23.71 | 0.224330E+09 | 449.31 | 21-OCT-12:09 | 30.90 | 25.77 |
November | 0.756783E+10 | 15828.03 | 25-NOV-07:02 | 21.17 | 18.83 | 0.216724E+09 | 449.44 | 25-NOV-13:00 | 26.20 | 22.04 |
December | 0.780844E+10 | 17078.98 | 21-DEC-07:03 | 18.83 | 17.79 | 0.224035E+09 | 449.40 | 02-DEC-13:20 | 29.93 | 23.09 |
Annual Sum or Average | 0.974795E+11 | 0.266669E+10 | ||||||||
Minimum of Months | 0.756783E+10 | 12722.16 | 18.83 | 17.56 | 0.203840E+09 | 449.26 | 24.40 | 21.64 | ||
Maximum of Months | 0.886166E+10 | 17388.08 | 26.15 | 24.37 | 0.230368E+09 | 449.45 | 37.10 | 27.84 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.810873E+10 | 16777.74 | 24-JAN-07:02 | 19.50 | 17.56 | 0.224376E+09 | 449.42 | 28-JAN-13:09 | 31.75 | 21.64 |
February | 0.768232E+10 | 17467.88 | 25-FEB-07:02 | 22.83 | 19.09 | 0.203841E+09 | 449.43 | 25-FEB-13:20 | 31.80 | 22.27 |
March | 0.874603E+10 | 15851.28 | 04-MAR-07:02 | 24.83 | 20.47 | 0.230369E+09 | 449.45 | 04-MAR-13:09 | 33.25 | 22.11 |
April | 0.853349E+10 | 14140.30 | 27-APR-06:01 | 26.15 | 23.95 | 0.219361E+09 | 449.31 | 22-APR-12:09 | 32.68 | 25.44 |
May | 0.891711E+10 | 12884.06 | 11-MAY-06:01 | 24.37 | 24.37 | 0.227432E+09 | 449.31 | 06-MAY-12:09 | 37.10 | 26.02 |
June | 0.891216E+10 | 12849.60 | 20-JUN-06:01 | 24.05 | 24.05 | 0.222567E+09 | 449.26 | 10-JUN-12:09 | 33.17 | 27.84 |
July | 0.805760E+10 | 14365.24 | 06-JUL-06:01 | 25.22 | 23.03 | 0.224164E+09 | 449.33 | 22-JUL-12:09 | 30.43 | 24.41 |
August | 0.805456E+10 | 13090.46 | 24-AUG-06:02 | 24.25 | 24.17 | 0.230271E+09 | 449.32 | 19-AUG-12:09 | 29.12 | 25.92 |
September | 0.783551E+10 | 12790.84 | 28-SEP-06:01 | 25.17 | 24.30 | 0.219227E+09 | 449.38 | 16-SEP-12:00 | 24.40 | 24.15 |
October | 0.763386E+10 | 12824.80 | 11-OCT-06:02 | 24.10 | 23.71 | 0.224331E+09 | 449.31 | 21-OCT-12:09 | 30.90 | 25.77 |
November | 0.758622E+10 | 15896.01 | 25-NOV-07:02 | 21.17 | 18.83 | 0.216723E+09 | 449.44 | 25-NOV-13:00 | 26.20 | 22.04 |
December | 0.782518E+10 | 17123.76 | 21-DEC-07:03 | 18.83 | 17.79 | 0.224035E+09 | 449.40 | 16-DEC-13:09 | 29.25 | 24.38 |
Annual Sum or Average | 0.978928E+11 | 0.266670E+10 | ||||||||
Minimum of Months | 0.758622E+10 | 12790.84 | 18.83 | 17.56 | 0.203841E+09 | 449.26 | 24.40 | 21.64 | ||
Maximum of Months | 0.891711E+10 | 17467.88 | 26.15 | 24.37 | 0.230369E+09 | 449.45 | 37.10 | 27.84 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.794325E+10 | 16536.18 | 24-JAN-07:02 | 19.50 | 17.56 | 0.224360E+09 | 449.42 | 28-JAN-13:09 | 31.75 | 21.64 |
February | 0.753217E+10 | 17196.60 | 25-FEB-07:02 | 22.83 | 19.09 | 0.203825E+09 | 449.43 | 25-FEB-13:00 | 32.20 | 22.17 |
March | 0.857467E+10 | 15590.37 | 04-MAR-07:02 | 24.83 | 20.47 | 0.230352E+09 | 449.45 | 04-MAR-13:20 | 33.20 | 22.07 |
April | 0.837088E+10 | 13865.42 | 27-APR-06:01 | 26.15 | 23.95 | 0.219345E+09 | 449.32 | 22-APR-12:09 | 32.68 | 25.44 |
May | 0.875928E+10 | 12633.11 | 11-MAY-06:01 | 24.37 | 24.37 | 0.227417E+09 | 449.31 | 06-MAY-12:09 | 37.10 | 26.02 |
June | 0.875517E+10 | 12624.64 | 20-JUN-06:01 | 24.05 | 24.05 | 0.222551E+09 | 449.27 | 10-JUN-12:09 | 33.17 | 27.84 |
July | 0.789793E+10 | 14113.26 | 06-JUL-06:01 | 25.22 | 23.03 | 0.224147E+09 | 449.34 | 22-JUL-12:09 | 30.43 | 24.41 |
August | 0.788091E+10 | 12821.87 | 24-AUG-06:02 | 24.25 | 24.17 | 0.230254E+09 | 449.32 | 19-AUG-12:09 | 29.12 | 25.92 |
September | 0.767329E+10 | 12526.20 | 28-SEP-06:01 | 25.17 | 24.30 | 0.219212E+09 | 449.39 | 16-SEP-12:00 | 24.40 | 24.15 |
October | 0.746611E+10 | 12591.98 | 11-OCT-06:02 | 24.10 | 23.71 | 0.224314E+09 | 449.31 | 21-OCT-12:09 | 30.90 | 25.77 |
November | 0.742291E+10 | 15651.06 | 25-NOV-07:02 | 21.17 | 18.83 | 0.216707E+09 | 449.40 | 25-NOV-13:09 | 26.53 | 21.45 |
December | 0.765611E+10 | 16139.48 | 27-DEC-07:02 | 20.50 | 19.41 | 0.224018E+09 | 449.40 | 16-DEC-13:09 | 29.25 | 24.38 |
Annual Sum or Average | 0.959327E+11 | 0.266650E+10 | ||||||||
Minimum of Months | 0.742291E+10 | 12526.20 | 19.50 | 17.56 | 0.203825E+09 | 449.27 | 24.40 | 21.45 | ||
Maximum of Months | 0.875928E+10 | 17196.60 | 26.15 | 24.37 | 0.230352E+09 | 449.45 | 37.10 | 27.84 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.133498E+11 | 30393.31 | 24-JAN-08:62 | 19.83 | 17.92 | 0.765530E+09 | 1198.59 | 28-JAN-15:00 | 32.10 | 22.08 |
February | 0.126783E+11 | 30526.30 | 23-FEB-08:62 | 23.33 | 20.34 | 0.697032E+09 | 1198.47 | 25-FEB-15:20 | 31.67 | 21.82 |
March | 0.144628E+11 | 28341.82 | 03-MAR-08:62 | 26.17 | 20.15 | 0.789372E+09 | 1198.38 | 04-MAR-15:00 | 33.20 | 22.29 |
April | 0.140854E+11 | 25435.35 | 27-APR-07:01 | 27.08 | 24.31 | 0.752179E+09 | 1198.18 | 15-APR-14:09 | 33.00 | 26.03 |
May | 0.148103E+11 | 23921.15 | 09-MAY-07:01 | 24.50 | 24.40 | 0.777600E+09 | 1198.31 | 06-MAY-14:09 | 37.00 | 27.33 |
June | 0.148523E+11 | 25001.62 | 20-JUN-07:01 | 24.58 | 24.46 | 0.762570E+09 | 1198.14 | 24-JUN-14:09 | 35.50 | 27.37 |
July | 0.132304E+11 | 26819.33 | 06-JUL-07:01 | 25.92 | 23.26 | 0.767151E+09 | 1198.24 | 01-JUL-14:00 | 30.30 | 24.75 |
August | 0.131853E+11 | 23822.33 | 30-AUG-07:02 | 25.50 | 24.07 | 0.789118E+09 | 1198.36 | 19-AUG-14:00 | 24.00 | 24.00 |
September | 0.128300E+11 | 24012.19 | 06-SEP-07:01 | 27.17 | 25.69 | 0.751946E+09 | 1198.40 | 16-SEP-14:30 | 26.25 | 24.93 |
October | 0.124040E+11 | 24549.39 | 11-OCT-07:02 | 24.92 | 24.20 | 0.765437E+09 | 1198.18 | 21-OCT-14:00 | 29.50 | 25.83 |
November | 0.123912E+11 | 28571.78 | 25-NOV-08:62 | 22.25 | 19.44 | 0.737098E+09 | 1198.40 | 25-NOV-15:00 | 25.40 | 22.47 |
December | 0.127926E+11 | 29566.92 | 21-DEC-08:62 | 21.33 | 19.10 | 0.766822E+09 | 1198.38 | 09-DEC-15:20 | 26.63 | 24.57 |
Annual Sum or Average | 0.161072E+12 | 0.912185E+10 | ||||||||
Minimum of Months | 0.123912E+11 | 23822.33 | 19.83 | 17.92 | 0.697032E+09 | 1198.14 | 24.00 | 21.82 | ||
Maximum of Months | 0.148523E+11 | 30526.30 | 27.17 | 25.69 | 0.789372E+09 | 1198.59 | 37.00 | 27.37 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.695684E+10 | 15862.24 | 24-JAN-08:62 | 19.83 | 17.92 | 0.382752E+09 | 599.28 | 28-JAN-15:00 | 32.10 | 22.08 |
February | 0.661758E+10 | 15951.57 | 23-FEB-08:62 | 23.33 | 20.34 | 0.348502E+09 | 599.23 | 25-FEB-15:20 | 31.67 | 21.82 |
March | 0.755314E+10 | 14794.40 | 03-MAR-08:62 | 26.17 | 20.15 | 0.394669E+09 | 599.18 | 04-MAR-15:00 | 33.20 | 22.29 |
April | 0.736440E+10 | 13331.31 | 27-APR-07:01 | 27.08 | 24.31 | 0.376066E+09 | 599.07 | 15-APR-14:09 | 33.00 | 26.03 |
May | 0.774239E+10 | 12522.22 | 09-MAY-07:01 | 24.50 | 24.40 | 0.388776E+09 | 599.13 | 06-MAY-14:09 | 37.00 | 27.33 |
June | 0.775159E+10 | 13088.08 | 20-JUN-07:01 | 24.58 | 24.46 | 0.381262E+09 | 599.05 | 24-JUN-14:09 | 35.50 | 27.37 |
July | 0.688484E+10 | 14046.95 | 06-JUL-07:01 | 25.92 | 23.26 | 0.383550E+09 | 599.11 | 01-JUL-14:50 | 30.42 | 24.71 |
August | 0.686176E+10 | 12477.23 | 29-AUG-07:01 | 26.25 | 25.69 | 0.394541E+09 | 599.17 | 19-AUG-14:00 | 24.00 | 24.00 |
September | 0.668291E+10 | 12601.37 | 06-SEP-07:01 | 27.17 | 25.69 | 0.375952E+09 | 599.20 | 16-SEP-14:30 | 26.25 | 24.93 |
October | 0.645349E+10 | 12870.00 | 11-OCT-07:02 | 24.92 | 24.20 | 0.382701E+09 | 599.07 | 21-OCT-14:00 | 29.50 | 25.83 |
November | 0.644289E+10 | 14909.41 | 25-NOV-08:62 | 22.25 | 19.44 | 0.368535E+09 | 599.19 | 25-NOV-15:00 | 25.40 | 22.47 |
December | 0.665546E+10 | 15386.28 | 27-DEC-08:62 | 23.50 | 19.74 | 0.383396E+09 | 599.18 | 09-DEC-15:09 | 26.82 | 24.70 |
Annual Sum or Average | 0.839673E+11 | 0.456070E+10 | ||||||||
Minimum of Months | 0.644289E+10 | 12477.23 | 19.83 | 17.92 | 0.348502E+09 | 599.05 | 24.00 | 21.82 | ||
Maximum of Months | 0.775159E+10 | 15951.57 | 27.17 | 25.69 | 0.394669E+09 | 599.28 | 37.00 | 27.37 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.690378E+10 | 15755.58 | 24-JAN-08:62 | 19.83 | 17.92 | 0.382749E+09 | 599.28 | 28-JAN-15:00 | 32.10 | 22.08 |
February | 0.657183E+10 | 15839.66 | 23-FEB-08:62 | 23.33 | 20.34 | 0.348499E+09 | 599.23 | 25-FEB-15:20 | 31.67 | 21.82 |
March | 0.750297E+10 | 14691.68 | 03-MAR-08:62 | 26.17 | 20.15 | 0.394667E+09 | 599.18 | 04-MAR-15:00 | 33.20 | 22.29 |
April | 0.731742E+10 | 13230.69 | 27-APR-07:01 | 27.08 | 24.31 | 0.376063E+09 | 599.07 | 15-APR-14:09 | 33.00 | 26.03 |
May | 0.769370E+10 | 12430.81 | 09-MAY-07:01 | 24.50 | 24.40 | 0.388773E+09 | 599.13 | 06-MAY-14:09 | 37.00 | 27.33 |
June | 0.770234E+10 | 12991.54 | 20-JUN-07:01 | 24.58 | 24.46 | 0.381259E+09 | 599.05 | 24-JUN-14:09 | 35.50 | 27.37 |
July | 0.683740E+10 | 13944.26 | 06-JUL-07:01 | 25.92 | 23.26 | 0.383547E+09 | 599.11 | 01-JUL-14:50 | 30.42 | 24.71 |
August | 0.681282E+10 | 12380.63 | 29-AUG-07:01 | 26.25 | 25.69 | 0.394539E+09 | 599.18 | 19-AUG-14:00 | 24.00 | 24.00 |
September | 0.663689E+10 | 12511.33 | 06-SEP-07:01 | 27.17 | 25.69 | 0.375950E+09 | 599.20 | 16-SEP-14:30 | 26.25 | 24.93 |
October | 0.640405E+10 | 12772.01 | 11-OCT-07:02 | 24.92 | 24.20 | 0.382698E+09 | 599.07 | 21-OCT-14:00 | 29.50 | 25.83 |
November | 0.639191E+10 | 14802.62 | 25-NOV-08:62 | 22.25 | 19.44 | 0.368532E+09 | 599.19 | 25-NOV-15:00 | 25.40 | 22.47 |
December | 0.660222E+10 | 15278.62 | 27-DEC-08:62 | 23.50 | 19.74 | 0.383392E+09 | 599.18 | 09-DEC-15:09 | 26.82 | 24.70 |
Annual Sum or Average | 0.833773E+11 | 0.456067E+10 | ||||||||
Minimum of Months | 0.639191E+10 | 12380.63 | 19.83 | 17.92 | 0.348499E+09 | 599.05 | 24.00 | 21.82 | ||
Maximum of Months | 0.770234E+10 | 15839.66 | 27.17 | 25.69 | 0.394667E+09 | 599.28 | 37.00 | 27.37 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.690105E+10 | 15738.76 | 24-JAN-08:62 | 19.83 | 17.92 | 0.382748E+09 | 599.28 | 28-JAN-15:00 | 32.10 | 22.08 |
February | 0.658895E+10 | 15859.51 | 23-FEB-08:62 | 23.33 | 20.34 | 0.348499E+09 | 599.23 | 25-FEB-15:20 | 31.67 | 21.82 |
March | 0.752922E+10 | 14685.70 | 03-MAR-08:62 | 26.17 | 20.15 | 0.394667E+09 | 599.18 | 04-MAR-15:00 | 33.20 | 22.29 |
April | 0.735816E+10 | 13239.77 | 27-APR-07:01 | 27.08 | 24.31 | 0.376064E+09 | 599.07 | 15-APR-14:09 | 33.00 | 26.03 |
May | 0.773364E+10 | 12445.31 | 09-MAY-07:01 | 24.50 | 24.40 | 0.388775E+09 | 599.13 | 06-MAY-14:09 | 37.00 | 27.33 |
June | 0.775087E+10 | 13028.36 | 20-JUN-07:01 | 24.58 | 24.46 | 0.381260E+09 | 599.05 | 24-JUN-14:09 | 35.50 | 27.37 |
July | 0.686622E+10 | 13966.35 | 06-JUL-07:01 | 25.92 | 23.26 | 0.383548E+09 | 599.11 | 01-JUL-14:50 | 30.42 | 24.71 |
August | 0.683715E+10 | 12416.88 | 29-AUG-07:01 | 26.25 | 25.69 | 0.394538E+09 | 599.18 | 19-AUG-14:50 | 25.00 | 24.56 |
September | 0.666576E+10 | 12553.99 | 06-SEP-07:01 | 27.17 | 25.69 | 0.375950E+09 | 599.19 | 16-SEP-14:39 | 26.50 | 25.13 |
October | 0.640327E+10 | 12762.85 | 11-OCT-07:02 | 24.92 | 24.20 | 0.382698E+09 | 599.07 | 21-OCT-14:00 | 29.50 | 25.83 |
November | 0.638912E+10 | 14799.31 | 25-NOV-08:62 | 22.25 | 19.44 | 0.368531E+09 | 599.19 | 25-NOV-15:00 | 25.40 | 22.47 |
December | 0.659160E+10 | 15269.23 | 27-DEC-08:62 | 23.50 | 19.74 | 0.383390E+09 | 599.18 | 09-DEC-15:09 | 26.82 | 24.70 |
Annual Sum or Average | 0.836150E+11 | 0.456067E+10 | ||||||||
Minimum of Months | 0.638912E+10 | 12416.88 | 19.83 | 17.92 | 0.348499E+09 | 599.05 | 25.00 | 21.82 | ||
Maximum of Months | 0.775087E+10 | 15859.51 | 27.17 | 25.69 | 0.394667E+09 | 599.28 | 37.00 | 27.37 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.801153E+10 | 17271.66 | 24-JAN-08:62 | 19.83 | 17.92 | 0.382805E+09 | 599.26 | 28-JAN-15:00 | 32.10 | 22.08 |
February | 0.778500E+10 | 17919.62 | 23-FEB-08:62 | 23.33 | 20.34 | 0.348558E+09 | 599.23 | 25-FEB-15:09 | 31.83 | 22.02 |
March | 0.897544E+10 | 15816.68 | 03-MAR-08:62 | 26.17 | 20.15 | 0.394724E+09 | 599.25 | 04-MAR-15:00 | 33.20 | 22.29 |
April | 0.885753E+10 | 13943.07 | 27-APR-07:01 | 27.08 | 24.31 | 0.376132E+09 | 599.05 | 15-APR-14:09 | 33.00 | 26.03 |
May | 0.918924E+10 | 13173.65 | 11-MAY-07:02 | 26.50 | 26.26 | 0.388836E+09 | 599.09 | 06-MAY-14:30 | 37.00 | 27.33 |
June | 0.930771E+10 | 14090.20 | 20-JUN-07:01 | 24.58 | 24.46 | 0.381314E+09 | 599.01 | 03-JUN-14:00 | 28.00 | 27.19 |
July | 0.816717E+10 | 15752.97 | 11-JUL-07:02 | 24.67 | 23.95 | 0.383632E+09 | 599.08 | 01-JUL-14:00 | 30.30 | 24.75 |
August | 0.815486E+10 | 13707.52 | 24-AUG-07:02 | 25.75 | 25.32 | 0.394580E+09 | 599.18 | 19-AUG-14:00 | 24.00 | 24.00 |
September | 0.797107E+10 | 13905.14 | 12-SEP-07:02 | 26.13 | 25.27 | 0.376016E+09 | 599.17 | 16-SEP-14:09 | 25.75 | 24.54 |
October | 0.743470E+10 | 13975.24 | 11-OCT-07:02 | 24.92 | 24.20 | 0.382755E+09 | 599.05 | 21-OCT-14:00 | 29.50 | 25.83 |
November | 0.743620E+10 | 16250.63 | 25-NOV-08:62 | 22.25 | 19.44 | 0.368573E+09 | 599.19 | 25-NOV-15:00 | 25.40 | 22.47 |
December | 0.763651E+10 | 16575.03 | 27-DEC-08:62 | 23.50 | 19.74 | 0.383449E+09 | 599.17 | 02-DEC-15:20 | 29.60 | 23.21 |
Annual Sum or Average | 0.989269E+11 | 0.456137E+10 | ||||||||
Minimum of Months | 0.743470E+10 | 13173.65 | 19.83 | 17.92 | 0.348558E+09 | 599.01 | 24.00 | 22.02 | ||
Maximum of Months | 0.930771E+10 | 17919.62 | 27.08 | 26.26 | 0.394724E+09 | 599.26 | 37.00 | 27.33 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 22918974.99 | 3110.39 | 03-JAN-08:05 | 27.00 |
February | 28110628.48 | 3218.10 | 18-FEB-08:05 | 27.33 |
March | 25982307.82 | 3305.32 | 30-MAR-07:06 | 27.67 |
April | 26473115.84 | 3622.34 | 11-APR-07:06 | 28.42 |
May | 16509196.52 | 5264.20 | 28-MAY-07:07 | 32.25 |
June | 17122388.32 | 3657.86 | 09-JUN-07:07 | 28.75 |
July | 26654228.80 | 2885.50 | 29-JUL-07:05 | 26.73 |
August | 21390943.55 | 3628.37 | 28-AUG-07:06 | 28.42 |
September | 23828708.01 | 3416.30 | 01-SEP-07:07 | 28.17 |
October | 23733644.04 | 3140.16 | 05-OCT-07:07 | 27.75 |
November | 20371910.17 | 3289.60 | 14-NOV-08:06 | 27.67 |
December | 23674594.01 | 2851.23 | 07-DEC-08:05 | 26.33 |
Annual Sum or Average | 0.276771E+09 | |||
Minimum of Months | 16509196.52 | 2851.23 | 26.33 | |
Maximum of Months | 28110628.48 | 5264.20 | 32.25 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 13196532.81 | 2209.17 | 11-JAN-08:05 | 29.33 |
February | 13866160.83 | 1756.03 | 18-FEB-08:05 | 27.33 |
March | 13736985.64 | 1789.10 | 09-MAR-08:05 | 27.50 |
April | 9870479.34 | 1804.94 | 15-APR-07:05 | 27.62 |
May | 10683190.29 | 2796.98 | 28-MAY-07:06 | 32.25 |
June | 8878818.55 | 1943.77 | 07-JUN-07:06 | 28.67 |
July | 12415702.77 | 1581.62 | 29-JUL-07:05 | 26.73 |
August | 12886014.24 | 1898.37 | 09-AUG-07:06 | 28.75 |
September | 11423235.12 | 1745.74 | 02-SEP-07:05 | 27.67 |
October | 14226926.04 | 1737.53 | 05-OCT-07:05 | 27.75 |
November | 11515936.06 | 1711.07 | 07-NOV-08:05 | 27.25 |
December | 12117817.77 | 1737.22 | 09-DEC-08:05 | 27.33 |
Annual Sum or Average | 0.144818E+09 | |||
Minimum of Months | 8878818.55 | 1581.62 | 26.73 | |
Maximum of Months | 14226926.04 | 2796.98 | 32.25 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 66402812.42 | 1832.64 | 29-JAN-17:02 | 30.83 |
February | 77602977.17 | 1812.93 | 12-FEB-17:02 | 30.67 |
March | 93117532.22 | 2741.79 | 19-MAR-16:01 | 34.25 |
April | 0.116825E+09 | 2516.81 | 02-APR-16:01 | 33.25 |
May | 0.103193E+09 | 2813.02 | 29-MAY-16:01 | 34.50 |
June | 0.101835E+09 | 2749.32 | 11-JUN-16:01 | 34.25 |
July | 82394110.30 | 2388.14 | 15-JUL-17:02 | 32.83 |
August | 72140832.48 | 2363.46 | 27-AUG-16:02 | 32.83 |
September | 80062633.80 | 2372.85 | 04-SEP-16:02 | 32.83 |
October | 67275205.28 | 1582.24 | 08-OCT-16:02 | 29.72 |
November | 56735103.12 | 1583.19 | 17-NOV-20:03 | 29.48 |
December | 50497692.35 | 1425.84 | 10-DEC-17:02 | 29.00 |
Annual Sum or Average | 0.968081E+09 | |||
Minimum of Months | 50497692.35 | 1425.84 | 29.00 | |
Maximum of Months | 0.116825E+09 | 2813.02 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 66098747.33 | 1832.91 | 29-JAN-17:02 | 30.83 |
February | 77310547.43 | 1813.26 | 12-FEB-17:02 | 30.67 |
March | 92831962.65 | 2741.37 | 19-MAR-16:01 | 34.25 |
April | 0.116873E+09 | 2516.21 | 02-APR-16:01 | 33.25 |
May | 0.103074E+09 | 2812.21 | 29-MAY-16:01 | 34.50 |
June | 0.101476E+09 | 2748.22 | 11-JUN-16:01 | 34.25 |
July | 81909072.77 | 2388.25 | 15-JUL-17:02 | 32.83 |
August | 72012453.43 | 2362.93 | 27-AUG-16:02 | 32.83 |
September | 79934419.00 | 2372.03 | 04-SEP-16:02 | 32.83 |
October | 67239957.05 | 1582.10 | 08-OCT-16:02 | 29.72 |
November | 56796548.24 | 1587.19 | 23-NOV-08:06 | 27.25 |
December | 50403869.91 | 1426.28 | 10-DEC-17:02 | 29.00 |
Annual Sum or Average | 0.965961E+09 | |||
Minimum of Months | 50403869.91 | 1426.28 | 27.25 | |
Maximum of Months | 0.116873E+09 | 2812.21 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 67884401.78 | 1837.50 | 29-JAN-17:02 | 30.83 |
February | 78892237.55 | 1817.79 | 12-FEB-17:02 | 30.67 |
March | 94450564.10 | 2744.11 | 19-MAR-16:01 | 34.25 |
April | 0.117833E+09 | 2518.65 | 02-APR-16:01 | 33.25 |
May | 0.104390E+09 | 2814.52 | 29-MAY-16:01 | 34.50 |
June | 0.102850E+09 | 2750.62 | 11-JUN-16:01 | 34.25 |
July | 83236394.64 | 2393.00 | 15-JUL-17:02 | 32.83 |
August | 73120883.75 | 2366.35 | 27-AUG-16:02 | 32.83 |
September | 80897567.39 | 2375.04 | 04-SEP-16:02 | 32.83 |
October | 68010273.45 | 1586.25 | 08-OCT-16:02 | 29.72 |
November | 58017510.59 | 1589.78 | 17-NOV-20:03 | 29.48 |
December | 51872109.64 | 1430.33 | 10-DEC-17:02 | 29.00 |
Annual Sum or Average | 0.981454E+09 | |||
Minimum of Months | 51872109.64 | 1430.33 | 29.00 | |
Maximum of Months | 0.117833E+09 | 2814.52 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 66085233.41 | 3703.65 | 29-JAN-17:02 | 30.83 |
February | 85851387.85 | 3658.31 | 12-FEB-17:02 | 30.67 |
March | 86199419.09 | 5495.54 | 19-MAR-16:01 | 34.25 |
April | 0.102999E+09 | 5038.20 | 02-APR-16:01 | 33.25 |
May | 92916384.84 | 5635.79 | 29-MAY-16:01 | 34.50 |
June | 76460227.45 | 5509.28 | 11-JUN-16:01 | 34.25 |
July | 0.104097E+09 | 4797.85 | 15-JUL-17:02 | 32.83 |
August | 65859756.41 | 4750.51 | 27-AUG-16:02 | 32.83 |
September | 78081894.23 | 4763.96 | 04-SEP-16:02 | 32.83 |
October | 70557774.09 | 3195.64 | 08-OCT-08:07 | 28.25 |
November | 55681395.82 | 3380.47 | 23-NOV-09:06 | 28.57 |
December | 64903190.87 | 3360.26 | 31-DEC-09:07 | 28.47 |
Annual Sum or Average | 0.949693E+09 | |||
Minimum of Months | 55681395.82 | 3195.64 | 28.25 | |
Maximum of Months | 0.104097E+09 | 5635.79 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 34881335.92 | 1858.35 | 29-JAN-17:02 | 30.83 |
February | 43769266.15 | 1836.96 | 12-FEB-17:02 | 30.67 |
March | 42995179.05 | 2755.52 | 19-MAR-16:01 | 34.25 |
April | 51032411.65 | 2528.21 | 02-APR-16:01 | 33.25 |
May | 47462549.68 | 2824.28 | 29-MAY-16:01 | 34.50 |
June | 37952251.67 | 2761.94 | 11-JUN-16:01 | 34.25 |
July | 52756429.63 | 2415.31 | 15-JUL-17:02 | 32.83 |
August | 32014555.82 | 2382.16 | 27-AUG-16:02 | 32.83 |
September | 39177558.66 | 2388.61 | 04-SEP-16:02 | 32.83 |
October | 36166397.41 | 1604.79 | 08-OCT-16:02 | 29.72 |
November | 27823602.98 | 1582.93 | 14-NOV-08:06 | 27.67 |
December | 33266677.61 | 1660.86 | 31-DEC-09:07 | 28.47 |
Annual Sum or Average | 0.479298E+09 | |||
Minimum of Months | 27823602.98 | 1582.93 | 27.67 | |
Maximum of Months | 52756429.63 | 2824.28 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 35038527.66 | 1859.62 | 29-JAN-17:02 | 30.83 |
February | 43779603.17 | 1838.03 | 12-FEB-17:02 | 30.67 |
March | 43782666.25 | 2756.15 | 19-MAR-16:01 | 34.25 |
April | 51125973.57 | 2528.72 | 02-APR-16:01 | 33.25 |
May | 47506603.66 | 2824.85 | 29-MAY-16:01 | 34.50 |
June | 38058565.81 | 2762.60 | 11-JUN-16:01 | 34.25 |
July | 52828939.54 | 2416.28 | 15-JUL-17:02 | 32.83 |
August | 32229838.93 | 2382.99 | 27-AUG-16:02 | 32.83 |
September | 39191923.46 | 2389.34 | 04-SEP-16:02 | 32.83 |
October | 36983132.56 | 1605.84 | 08-OCT-16:02 | 29.72 |
November | 27946435.49 | 1574.81 | 14-NOV-08:06 | 27.67 |
December | 33352652.22 | 1653.76 | 31-DEC-09:07 | 28.47 |
Annual Sum or Average | 0.481825E+09 | |||
Minimum of Months | 27946435.49 | 1574.81 | 27.67 | |
Maximum of Months | 52828939.54 | 2824.85 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 35018269.47 | 2018.32 | 11-JAN-08:05 | 29.33 |
February | 42706515.20 | 1837.94 | 12-FEB-17:02 | 30.67 |
March | 43776945.29 | 2755.19 | 19-MAR-16:01 | 34.25 |
April | 51363103.84 | 2527.57 | 02-APR-16:01 | 33.25 |
May | 47789574.40 | 2823.56 | 29-MAY-16:01 | 34.50 |
June | 38444067.40 | 2760.87 | 11-JUN-16:01 | 34.25 |
July | 53069991.88 | 2415.06 | 15-JUL-17:02 | 32.83 |
August | 33648822.77 | 2381.48 | 27-AUG-16:02 | 32.83 |
September | 39331168.26 | 2387.80 | 04-SEP-16:02 | 32.83 |
October | 38287647.17 | 1604.99 | 08-OCT-16:02 | 29.72 |
November | 29031257.32 | 1556.52 | 14-NOV-08:06 | 27.67 |
December | 32815015.12 | 1633.01 | 31-DEC-09:07 | 28.47 |
Annual Sum or Average | 0.485282E+09 | |||
Minimum of Months | 29031257.32 | 1556.52 | 27.67 | |
Maximum of Months | 53069991.88 | 2823.56 | 34.50 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 31089076.53 | 2114.61 | 11-JAN-08:05 | 29.33 |
February | 37548379.11 | 1807.56 | 12-FEB-17:02 | 30.67 |
March | 37891030.26 | 2725.69 | 19-MAR-16:01 | 34.25 |
April | 46907269.11 | 2500.13 | 02-APR-16:01 | 33.25 |
May | 43324380.87 | 2792.22 | 29-MAY-16:01 | 34.50 |
June | 34695732.03 | 2726.02 | 11-JUN-16:01 | 34.25 |
July | 48826874.05 | 2376.47 | 15-JUL-17:02 | 32.83 |
August | 30501905.05 | 2342.90 | 27-AUG-16:02 | 32.83 |
September | 36440947.09 | 2350.84 | 04-SEP-16:02 | 32.83 |
October | 35352449.12 | 1646.26 | 08-OCT-08:07 | 28.25 |
November | 25284737.86 | 1816.19 | 23-NOV-09:06 | 28.57 |
December | 28295568.19 | 1717.19 | 31-DEC-09:07 | 28.47 |
Annual Sum or Average | 0.436158E+09 | |||
Minimum of Months | 25284737.86 | 1646.26 | 28.25 | |
Maximum of Months | 48826874.05 | 2792.22 | 34.50 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.900155E+10 | 5587.06 | 01-JAN-10:09 | 0.222596E+10 | 1343.25 | 01-JAN-10:09 |
February | 0.814396E+10 | 5587.06 | 01-FEB-10:09 | 0.201408E+10 | 1343.25 | 01-FEB-10:09 |
March | 0.901902E+10 | 5587.06 | 01-MAR-10:09 | 0.223053E+10 | 1343.25 | 01-MAR-10:09 |
April | 0.873329E+10 | 5587.06 | 01-APR-09:09 | 0.215990E+10 | 1343.25 | 01-APR-09:09 |
May | 0.900155E+10 | 5587.06 | 01-MAY-09:09 | 0.222596E+10 | 1343.25 | 01-MAY-09:09 |
June | 0.873302E+10 | 5587.06 | 01-JUN-09:09 | 0.215990E+10 | 1343.25 | 01-JUN-09:09 |
July | 0.901915E+10 | 5587.06 | 01-JUL-09:09 | 0.223053E+10 | 1343.25 | 01-JUL-09:09 |
August | 0.900155E+10 | 5587.06 | 01-AUG-09:09 | 0.222596E+10 | 1343.25 | 01-AUG-09:09 |
September | 0.875049E+10 | 5587.06 | 01-SEP-09:09 | 0.216447E+10 | 1343.25 | 01-SEP-09:09 |
October | 0.900168E+10 | 5587.06 | 01-OCT-09:09 | 0.222596E+10 | 1343.25 | 01-OCT-09:09 |
November | 0.869809E+10 | 5587.06 | 01-NOV-09:09 | 0.215077E+10 | 1343.25 | 01-NOV-09:09 |
December | 0.903649E+10 | 5587.06 | 01-DEC-10:09 | 0.223509E+10 | 1343.25 | 01-DEC-10:09 |
Annual Sum or Average | 0.106140E+12 | 0.262491E+11 | ||||
Minimum of Months | 0.814396E+10 | 5587.06 | 0.201408E+10 | 1343.25 | ||
Maximum of Months | 0.903649E+10 | 5587.06 | 0.223509E+10 | 1343.25 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.525997E+10 | 3268.27 | 01-JAN-10:09 | 0.111298E+10 | 671.63 | 01-JAN-10:09 |
February | 0.475885E+10 | 3268.27 | 01-FEB-10:09 | 0.100704E+10 | 671.63 | 01-FEB-10:09 |
March | 0.527019E+10 | 3268.27 | 01-MAR-10:09 | 0.111526E+10 | 671.63 | 01-MAR-10:09 |
April | 0.510323E+10 | 3268.27 | 01-APR-09:09 | 0.107995E+10 | 671.63 | 01-APR-09:09 |
May | 0.525997E+10 | 3268.27 | 01-MAY-09:09 | 0.111298E+10 | 671.63 | 01-MAY-09:09 |
June | 0.510306E+10 | 3268.27 | 01-JUN-09:09 | 0.107995E+10 | 671.63 | 01-JUN-09:09 |
July | 0.527027E+10 | 3268.27 | 01-JUL-09:09 | 0.111526E+10 | 671.63 | 01-JUL-09:09 |
August | 0.525997E+10 | 3268.27 | 01-AUG-09:09 | 0.111298E+10 | 671.63 | 01-AUG-09:09 |
September | 0.511328E+10 | 3268.27 | 01-SEP-09:09 | 0.108223E+10 | 671.63 | 01-SEP-09:09 |
October | 0.526005E+10 | 3268.27 | 01-OCT-09:09 | 0.111298E+10 | 671.63 | 01-OCT-09:09 |
November | 0.508263E+10 | 3268.27 | 01-NOV-09:09 | 0.107538E+10 | 671.63 | 01-NOV-09:09 |
December | 0.528040E+10 | 3268.27 | 01-DEC-10:09 | 0.111755E+10 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.620219E+11 | 0.131245E+11 | ||||
Minimum of Months | 0.475885E+10 | 3268.27 | 0.100704E+10 | 671.63 | ||
Maximum of Months | 0.528040E+10 | 3268.27 | 0.111755E+10 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.372206E+10 | 3006.97 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.337152E+10 | 3006.97 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.380758E+10 | 3006.97 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.361234E+10 | 3006.97 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.376482E+10 | 3006.97 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.367648E+10 | 3006.97 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.370068E+10 | 3006.97 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.380758E+10 | 3006.97 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.361234E+10 | 3006.97 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.372206E+10 | 3006.97 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.361234E+10 | 3006.97 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.370068E+10 | 3006.97 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.441105E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.337152E+10 | 3006.97 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.380758E+10 | 3006.97 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.372206E+10 | 3006.97 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.337152E+10 | 3006.97 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.380758E+10 | 3006.97 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.361234E+10 | 3006.97 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.376482E+10 | 3006.97 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.367648E+10 | 3006.97 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.370068E+10 | 3006.97 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.380758E+10 | 3006.97 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.361234E+10 | 3006.97 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.372206E+10 | 3006.97 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.361234E+10 | 3006.97 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.370068E+10 | 3006.97 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.441105E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.337152E+10 | 3006.97 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.380758E+10 | 3006.97 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.372206E+10 | 3006.97 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.337152E+10 | 3006.97 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.380758E+10 | 3006.97 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.361234E+10 | 3006.97 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.376482E+10 | 3006.97 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.367648E+10 | 3006.97 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.370068E+10 | 3006.97 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.380758E+10 | 3006.97 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.361234E+10 | 3006.97 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.372206E+10 | 3006.97 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.361234E+10 | 3006.97 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.370068E+10 | 3006.97 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.441105E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.337152E+10 | 3006.97 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.380758E+10 | 3006.97 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.422804E+10 | 3712.57 | 01-JAN-11:09 | 0.161799E+10 | 1343.25 | 01-JAN-11:09 |
February | 0.383070E+10 | 3712.57 | 01-FEB-10:09 | 0.146554E+10 | 1343.25 | 01-FEB-10:09 |
March | 0.433280E+10 | 3712.57 | 01-MAR-10:09 | 0.165455E+10 | 1343.25 | 01-MAR-10:09 |
April | 0.410432E+10 | 3712.57 | 01-APR-09:09 | 0.157022E+10 | 1343.25 | 01-APR-09:09 |
May | 0.428042E+10 | 3712.57 | 01-MAY-09:09 | 0.163627E+10 | 1343.25 | 01-MAY-09:09 |
June | 0.418290E+10 | 3712.57 | 01-JUN-09:09 | 0.159764E+10 | 1343.25 | 01-JUN-09:09 |
July | 0.420185E+10 | 3712.57 | 01-JUL-09:09 | 0.160885E+10 | 1343.25 | 01-JUL-09:09 |
August | 0.433280E+10 | 3712.57 | 01-AUG-09:09 | 0.165455E+10 | 1343.25 | 01-AUG-09:09 |
September | 0.410432E+10 | 3712.57 | 01-SEP-09:09 | 0.157022E+10 | 1343.25 | 01-SEP-09:09 |
October | 0.422804E+10 | 3712.57 | 01-OCT-10:09 | 0.161799E+10 | 1343.25 | 01-OCT-10:09 |
November | 0.410432E+10 | 3712.57 | 01-NOV-09:09 | 0.157022E+10 | 1343.25 | 01-NOV-09:09 |
December | 0.420185E+10 | 3712.57 | 01-DEC-10:09 | 0.160885E+10 | 1343.25 | 01-DEC-10:09 |
Annual Sum or Average | 0.501324E+11 | 0.191729E+11 | ||||
Minimum of Months | 0.383070E+10 | 3712.57 | 0.146554E+10 | 1343.25 | ||
Maximum of Months | 0.433280E+10 | 3712.57 | 0.165455E+10 | 1343.25 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.211402E+10 | 1856.29 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.191535E+10 | 1856.29 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.216640E+10 | 1856.29 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.205216E+10 | 1856.29 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.214021E+10 | 1856.29 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.209145E+10 | 1856.29 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.210092E+10 | 1856.29 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.216640E+10 | 1856.29 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.205216E+10 | 1856.29 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.211402E+10 | 1856.29 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.205216E+10 | 1856.29 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.210092E+10 | 1856.29 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.250662E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.191535E+10 | 1856.29 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.216640E+10 | 1856.29 | 0.827277E+09 | 671.63 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.900155E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.222980E+10 | 49802590.72 |
February | 0.163016E+10 | 0.814396E+10 | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240769E+10 | 11644096.60 |
March | 0.178954E+10 | 0.901902E+10 | 0.223053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291039E+10 | 17431629.36 |
April | 0.174484E+10 | 0.873329E+10 | 0.215990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.289097E+10 | 2849372.05 |
May | 0.179537E+10 | 0.900155E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.292396E+10 | 8122951.20 |
June | 0.173447E+10 | 0.873302E+10 | 0.215990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.285531E+10 | 8665787.74 |
July | 0.181028E+10 | 0.901915E+10 | 0.223053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214349E+10 | 7293706.71 |
August | 0.178501E+10 | 0.900155E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.217862E+10 | 17063219.30 |
September | 0.174937E+10 | 0.875049E+10 | 0.216447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214361E+10 | 7719545.96 |
October | 0.180574E+10 | 0.900168E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188896E+10 | 16699794.53 |
November | 0.174613E+10 | 0.869809E+10 | 0.215077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182290E+10 | 22466225.29 |
December | 0.181481E+10 | 0.903649E+10 | 0.223509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198264E+10 | 49255072.79 |
Annual Sum or Average | 0.212115E+11 | 0.106140E+12 | 0.262491E+11 | 0.283783E+11 | 0.219014E+09 | ||||
Minimum of Months | 0.163016E+10 | 0.814396E+10 | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182290E+10 | 2849372.05 |
Maximum of Months | 0.181481E+10 | 0.903649E+10 | 0.223509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.292396E+10 | 49802590.72 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.525997E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125724E+10 | 16476131.68 |
February | 0.815075E+09 | 0.475885E+10 | 0.100704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135327E+10 | 3688081.66 |
March | 0.894769E+09 | 0.527019E+10 | 0.111526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162488E+10 | 5136674.36 |
April | 0.872416E+09 | 0.510323E+10 | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161467E+10 | 946839.08 |
May | 0.897684E+09 | 0.525997E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162798E+10 | 2418575.11 |
June | 0.867232E+09 | 0.510306E+10 | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159313E+10 | 2538821.57 |
July | 0.905135E+09 | 0.527027E+10 | 0.111526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120145E+10 | 2230271.97 |
August | 0.892501E+09 | 0.525997E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121562E+10 | 5900105.14 |
September | 0.874683E+09 | 0.511328E+10 | 0.108223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120390E+10 | 2343656.88 |
October | 0.902868E+09 | 0.526005E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106212E+10 | 5541877.68 |
November | 0.873064E+09 | 0.508263E+10 | 0.107538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102799E+10 | 6927660.90 |
December | 0.907403E+09 | 0.528040E+10 | 0.111755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111995E+10 | 14748240.76 |
Annual Sum or Average | 0.106057E+11 | 0.620219E+11 | 0.131245E+11 | 0.159022E+11 | 68896936.80 | ||||
Minimum of Months | 0.815075E+09 | 0.475885E+10 | 0.100704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102799E+10 | 946839.08 |
Maximum of Months | 0.907403E+09 | 0.528040E+10 | 0.111755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162798E+10 | 16476131.68 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123186E+10 | 21923094.72 |
February | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132893E+10 | 5660427.52 |
March | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160131E+10 | 7968141.58 |
April | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158883E+10 | 2056037.71 |
May | 0.544247E+09 | 0.376482E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160233E+10 | 4302776.71 |
June | 0.532585E+09 | 0.367648E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157033E+10 | 5442036.67 |
July | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117384E+10 | 6154629.81 |
August | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119711E+10 | 10331055.43 |
September | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118212E+10 | 6672274.23 |
October | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104040E+10 | 12115933.77 |
November | 0.518979E+09 | 0.361234E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100944E+10 | 12533719.16 |
December | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109671E+10 | 21881612.21 |
Annual Sum or Average | 0.638324E+10 | 0.441105E+11 | 0.104207E+11 | 0.156232E+11 | 0.117042E+09 | ||||
Minimum of Months | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100944E+10 | 2056037.71 |
Maximum of Months | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160233E+10 | 21923094.72 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123178E+10 | 22356495.14 |
February | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132870E+10 | 5928861.14 |
March | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160077E+10 | 8419146.64 |
April | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158796E+10 | 2167113.20 |
May | 0.544247E+09 | 0.376482E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160142E+10 | 4511040.87 |
June | 0.532585E+09 | 0.367648E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156952E+10 | 5700266.61 |
July | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117347E+10 | 6446622.42 |
August | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119680E+10 | 10655744.23 |
September | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118182E+10 | 6904535.85 |
October | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104026E+10 | 12465128.68 |
November | 0.518979E+09 | 0.361234E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100934E+10 | 12753181.97 |
December | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109665E+10 | 22164496.65 |
Annual Sum or Average | 0.638324E+10 | 0.441105E+11 | 0.104207E+11 | 0.156185E+11 | 0.120473E+09 | ||||
Minimum of Months | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100934E+10 | 2167113.20 |
Maximum of Months | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160142E+10 | 22356495.14 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123210E+10 | 21239042.65 |
February | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132918E+10 | 5276309.91 |
March | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160172E+10 | 7285178.06 |
April | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158940E+10 | 1891843.16 |
May | 0.544247E+09 | 0.376482E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160259E+10 | 4067485.45 |
June | 0.532585E+09 | 0.367648E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157064E+10 | 5264204.31 |
July | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117408E+10 | 5901171.98 |
August | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119739E+10 | 9594547.83 |
September | 0.524810E+09 | 0.361234E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118236E+10 | 6263048.10 |
October | 0.537120E+09 | 0.372206E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104063E+10 | 11562788.40 |
November | 0.518979E+09 | 0.361234E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100968E+10 | 11885722.14 |
December | 0.536472E+09 | 0.370068E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109691E+10 | 21109588.80 |
Annual Sum or Average | 0.638324E+10 | 0.441105E+11 | 0.104207E+11 | 0.156267E+11 | 0.111341E+09 | ||||
Minimum of Months | 0.487879E+09 | 0.337152E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100968E+10 | 1891843.16 |
Maximum of Months | 0.551374E+09 | 0.380758E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160259E+10 | 21239042.65 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.422804E+10 | 0.161799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.216346E+10 | 42098681.47 |
February | 0.167188E+10 | 0.383070E+10 | 0.146554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.233293E+10 | 9677822.29 |
March | 0.189386E+10 | 0.433280E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281716E+10 | 11686117.74 |
April | 0.180380E+10 | 0.410432E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.279629E+10 | 2892485.67 |
May | 0.186509E+10 | 0.428042E+10 | 0.163627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281887E+10 | 6698465.57 |
June | 0.182945E+10 | 0.418290E+10 | 0.159764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276223E+10 | 9251006.97 |
July | 0.183943E+10 | 0.420185E+10 | 0.160885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206039E+10 | 9943976.41 |
August | 0.189386E+10 | 0.433280E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210443E+10 | 15171291.03 |
September | 0.180380E+10 | 0.410432E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207453E+10 | 10263197.05 |
October | 0.183632E+10 | 0.422804E+10 | 0.161799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182453E+10 | 20182354.46 |
November | 0.176881E+10 | 0.410432E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176988E+10 | 21585769.58 |
December | 0.183943E+10 | 0.420185E+10 | 0.160885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.192241E+10 | 40741433.09 |
Annual Sum or Average | 0.218821E+11 | 0.501324E+11 | 0.191729E+11 | 0.274471E+11 | 0.200193E+09 | ||||
Minimum of Months | 0.167188E+10 | 0.383070E+10 | 0.146554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176988E+10 | 2892485.67 |
Maximum of Months | 0.189386E+10 | 0.433280E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281887E+10 | 42098681.47 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123466E+10 | 20966159.19 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133100E+10 | 4565056.79 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160603E+10 | 5352313.54 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159408E+10 | 1364810.60 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160612E+10 | 3086073.12 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157453E+10 | 4439162.86 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117534E+10 | 4787867.82 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119959E+10 | 7397783.38 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118357E+10 | 4946241.97 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104100E+10 | 9915755.87 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101022E+10 | 10666375.99 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109741E+10 | 19820058.13 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.156536E+11 | 97307659.27 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101022E+10 | 1364810.60 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160612E+10 | 20966159.19 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123479E+10 | 20732656.18 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133117E+10 | 4469417.23 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160632E+10 | 5221356.53 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159441E+10 | 1325373.64 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160642E+10 | 3029562.33 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157481E+10 | 4373885.39 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117553E+10 | 4696898.01 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119980E+10 | 7268123.10 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118374E+10 | 4854662.90 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104113E+10 | 9740662.09 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101036E+10 | 10500219.66 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109751E+10 | 19580323.16 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.156560E+11 | 95793140.21 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101036E+10 | 1325373.64 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160642E+10 | 20732656.18 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123486E+10 | 20342365.10 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133123E+10 | 4328981.92 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160654E+10 | 5009600.81 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159449E+10 | 1261778.32 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160642E+10 | 2951357.86 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157478E+10 | 4309432.46 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117550E+10 | 4635844.56 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119991E+10 | 7043031.76 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118378E+10 | 4760525.73 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104124E+10 | 9485347.00 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101051E+10 | 10200243.58 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109758E+10 | 19174637.09 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.156568E+11 | 93503146.19 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101051E+10 | 1261778.32 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160654E+10 | 20342365.10 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125767E+10 | 44093369.23 |
February | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136088E+10 | 11283865.69 |
March | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165885E+10 | 14425578.01 |
April | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.164806E+10 | 2850241.88 |
May | 0.932542E+09 | 0.214021E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166776E+10 | 8319349.38 |
June | 0.914724E+09 | 0.209145E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162874E+10 | 11049626.96 |
July | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120631E+10 | 11491370.05 |
August | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124004E+10 | 16056041.04 |
September | 0.901896E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121192E+10 | 11569556.04 |
October | 0.918158E+09 | 0.211402E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106452E+10 | 20436361.72 |
November | 0.884402E+09 | 0.205216E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102915E+10 | 22082152.50 |
December | 0.919713E+09 | 0.210092E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.111468E+10 | 46072886.63 |
Annual Sum or Average | 0.109410E+11 | 0.250662E+11 | 0.958644E+10 | 0.160886E+11 | 0.219730E+09 | ||||
Minimum of Months | 0.835938E+09 | 0.191535E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.102915E+10 | 2850241.88 |
Maximum of Months | 0.946926E+09 | 0.216640E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.166776E+10 | 46072886.63 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 5587.06 | 01-JAN-10:09 | 1343.25 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4734.24 | 04-JAN-13:00 | 713.34 | 07-JAN-05:00 |
February | 2159.72 | 03-FEB-13:09 | 5587.06 | 01-FEB-10:09 | 1343.25 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5178.10 | 28-FEB-15:00 | 267.07 | 21-FEB-10:00 |
March | 2159.72 | 03-MAR-13:09 | 5587.06 | 01-MAR-10:09 | 1343.25 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5732.63 | 21-MAR-13:00 | 131.84 | 03-MAR-05:40 |
April | 2159.72 | 01-APR-12:09 | 5587.06 | 01-APR-09:09 | 1343.25 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5254.66 | 01-APR-14:00 | 472.55 | 14-APR-16:00 |
May | 2159.72 | 05-MAY-12:09 | 5587.06 | 01-MAY-09:09 | 1343.25 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6232.71 | 06-MAY-13:00 | 234.21 | 21-MAY-13:00 |
June | 2159.72 | 02-JUN-12:09 | 5587.06 | 01-JUN-09:09 | 1343.25 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5569.21 | 13-JUN-15:00 | 231.24 | 30-JUN-13:00 |
July | 2159.72 | 01-JUL-12:09 | 5587.06 | 01-JUL-09:09 | 1343.25 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4236.24 | 28-JUL-13:00 | 338.31 | 03-JUL-13:00 |
August | 2159.72 | 04-AUG-12:09 | 5587.06 | 01-AUG-09:09 | 1343.25 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4684.07 | 27-AUG-14:00 | 834.33 | 20-AUG-11:10 |
September | 2159.72 | 01-SEP-12:09 | 5587.06 | 01-SEP-09:09 | 1343.25 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4656.26 | 06-SEP-14:00 | 440.57 | 15-SEP-17:00 |
October | 2159.72 | 01-OCT-12:09 | 5587.06 | 01-OCT-09:09 | 1343.25 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4213.44 | 04-OCT-14:00 | 427.24 | 30-OCT-17:00 |
November | 2159.72 | 03-NOV-12:09 | 5587.06 | 01-NOV-09:09 | 1343.25 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4761.03 | 18-NOV-13:00 | 196.68 | 25-NOV-08:62 |
December | 2159.72 | 01-DEC-13:09 | 5587.06 | 01-DEC-10:09 | 1343.25 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4176.69 | 07-DEC-14:00 | 264.14 | 21-DEC-05:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 5587.06 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4176.69 | 131.84 | |||||
Maximum of Months | 2159.72 | 5587.06 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 6232.71 | 834.33 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 3268.27 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.17 | 04-JAN-13:00 | 216.23 | 07-JAN-05:00 |
February | 1079.86 | 03-FEB-13:09 | 3268.27 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.98 | 28-FEB-15:00 | 146.29 | 21-FEB-10:00 |
March | 1079.86 | 03-MAR-13:09 | 3268.27 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.77 | 21-MAR-13:00 | 38.85 | 03-MAR-05:40 |
April | 1079.86 | 01-APR-12:09 | 3268.27 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.40 | 01-APR-14:00 | 267.43 | 14-APR-16:00 |
May | 1079.86 | 05-MAY-12:09 | 3268.27 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.14 | 06-MAY-13:00 | 132.50 | 21-MAY-13:00 |
June | 1079.86 | 02-JUN-12:09 | 3268.27 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.22 | 13-JUN-15:00 | 131.66 | 30-JUN-13:00 |
July | 1079.86 | 01-JUL-12:09 | 3268.27 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.13 | 15-JUL-16:00 | 189.09 | 03-JUL-13:00 |
August | 1079.86 | 04-AUG-12:09 | 3268.27 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.97 | 27-AUG-14:00 | 469.32 | 20-AUG-11:10 |
September | 1079.86 | 01-SEP-12:09 | 3268.27 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.54 | 06-SEP-14:00 | 244.75 | 15-SEP-17:00 |
October | 1079.86 | 01-OCT-12:09 | 3268.27 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.66 | 04-OCT-14:00 | 241.00 | 30-OCT-17:00 |
November | 1079.86 | 03-NOV-12:09 | 3268.27 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.22 | 18-NOV-13:00 | 104.93 | 25-NOV-08:62 |
December | 1079.86 | 01-DEC-13:09 | 3268.27 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.40 | 07-DEC-14:00 | 110.96 | 21-DEC-08:62 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3268.27 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.40 | 38.85 | |||||
Maximum of Months | 1079.86 | 3268.27 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.14 | 469.32 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3006.97 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.16 | 04-JAN-13:00 | 239.24 | 01-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3006.97 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.95 | 28-FEB-15:00 | 166.59 | 05-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3006.97 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.77 | 21-MAR-13:00 | 90.68 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3006.97 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.39 | 01-APR-14:00 | 267.45 | 14-APR-16:00 |
May | 1079.86 | 06-MAY-12:09 | 3006.97 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.13 | 06-MAY-13:00 | 132.53 | 21-MAY-13:00 |
June | 1079.86 | 03-JUN-12:09 | 3006.97 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.21 | 13-JUN-15:00 | 193.24 | 25-JUN-19:00 |
July | 1079.86 | 01-JUL-12:09 | 3006.97 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.13 | 15-JUL-16:00 | 427.24 | 16-JUL-17:00 |
August | 1079.86 | 05-AUG-12:09 | 3006.97 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.94 | 27-AUG-14:00 | 469.32 | 20-AUG-11:10 |
September | 1079.86 | 02-SEP-12:09 | 3006.97 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.51 | 06-SEP-14:00 | 440.67 | 03-SEP-17:00 |
October | 1079.86 | 07-OCT-12:09 | 3006.97 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.62 | 04-OCT-14:00 | 359.38 | 29-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 3006.97 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.26 | 18-NOV-13:00 | 515.99 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3006.97 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.39 | 07-DEC-14:00 | 359.64 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.39 | 90.68 | |||||
Maximum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.13 | 515.99 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3006.97 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.16 | 04-JAN-13:00 | 241.51 | 01-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3006.97 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.95 | 28-FEB-15:00 | 171.26 | 05-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3006.97 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.77 | 21-MAR-13:00 | 94.07 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3006.97 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.39 | 01-APR-14:00 | 267.45 | 14-APR-16:00 |
May | 1079.86 | 06-MAY-12:09 | 3006.97 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.13 | 06-MAY-13:00 | 132.52 | 21-MAY-13:00 |
June | 1079.86 | 03-JUN-12:09 | 3006.97 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.21 | 13-JUN-15:00 | 197.91 | 25-JUN-19:00 |
July | 1079.86 | 01-JUL-12:09 | 3006.97 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.13 | 15-JUL-16:00 | 432.93 | 16-JUL-17:00 |
August | 1079.86 | 05-AUG-12:09 | 3006.97 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.94 | 27-AUG-14:00 | 469.32 | 20-AUG-11:10 |
September | 1079.86 | 02-SEP-12:09 | 3006.97 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.51 | 06-SEP-14:00 | 445.17 | 03-SEP-17:00 |
October | 1079.86 | 07-OCT-12:09 | 3006.97 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.62 | 04-OCT-14:00 | 364.99 | 29-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 3006.97 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.26 | 18-NOV-13:00 | 516.28 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3006.97 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.39 | 07-DEC-14:00 | 360.21 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.39 | 94.07 | |||||
Maximum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.13 | 516.28 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3006.97 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.15 | 04-JAN-13:00 | 227.80 | 01-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3006.97 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.94 | 28-FEB-15:00 | 157.67 | 05-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3006.97 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.77 | 21-MAR-13:00 | 80.41 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 3006.97 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.38 | 01-APR-14:00 | 267.47 | 14-APR-16:00 |
May | 1079.86 | 06-MAY-12:09 | 3006.97 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.12 | 06-MAY-13:00 | 132.54 | 21-MAY-13:00 |
June | 1079.86 | 03-JUN-12:09 | 3006.97 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.20 | 13-JUN-15:00 | 193.85 | 25-JUN-19:00 |
July | 1079.86 | 01-JUL-12:09 | 3006.97 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.12 | 15-JUL-16:00 | 420.58 | 16-JUL-17:00 |
August | 1079.86 | 05-AUG-12:09 | 3006.97 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.93 | 27-AUG-14:00 | 469.32 | 20-AUG-11:10 |
September | 1079.86 | 02-SEP-12:09 | 3006.97 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.50 | 06-SEP-14:00 | 432.63 | 03-SEP-17:00 |
October | 1079.86 | 07-OCT-12:09 | 3006.97 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.61 | 04-OCT-14:00 | 351.59 | 29-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 3006.97 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.25 | 18-NOV-13:00 | 502.11 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3006.97 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.38 | 07-DEC-14:00 | 345.60 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.38 | 80.41 | |||||
Maximum of Months | 1079.86 | 3006.97 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.12 | 502.11 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 3712.57 | 01-JAN-11:09 | 1343.25 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4669.86 | 04-JAN-13:00 | 409.17 | 07-JAN-05:00 |
February | 2879.63 | 04-FEB-15:09 | 3712.57 | 01-FEB-10:09 | 1343.25 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5091.28 | 28-FEB-15:00 | 257.50 | 21-FEB-10:00 |
March | 2879.63 | 04-MAR-15:09 | 3712.57 | 01-MAR-10:09 | 1343.25 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5654.71 | 21-MAR-13:00 | 76.50 | 14-MAR-22:00 |
April | 2879.63 | 01-APR-14:09 | 3712.57 | 01-APR-09:09 | 1343.25 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5218.30 | 01-APR-14:00 | 468.70 | 14-APR-16:00 |
May | 2879.63 | 06-MAY-14:09 | 3712.57 | 01-MAY-09:09 | 1343.25 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 6164.38 | 06-MAY-13:00 | 232.43 | 21-MAY-13:00 |
June | 2879.63 | 03-JUN-14:09 | 3712.57 | 01-JUN-09:09 | 1343.25 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5493.71 | 13-JUN-15:00 | 343.68 | 25-JUN-19:00 |
July | 2879.63 | 01-JUL-14:09 | 3712.57 | 01-JUL-09:09 | 1343.25 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4206.31 | 15-JUL-16:00 | 670.44 | 16-JUL-17:00 |
August | 2879.63 | 05-AUG-14:09 | 3712.57 | 01-AUG-09:09 | 1343.25 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4620.22 | 27-AUG-14:00 | 823.01 | 20-AUG-11:10 |
September | 2879.63 | 02-SEP-14:09 | 3712.57 | 01-SEP-09:09 | 1343.25 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4605.12 | 06-SEP-14:00 | 695.43 | 03-SEP-17:00 |
October | 2879.63 | 07-OCT-14:09 | 3712.57 | 01-OCT-10:09 | 1343.25 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4167.11 | 04-OCT-14:00 | 559.37 | 29-OCT-17:00 |
November | 2879.63 | 04-NOV-14:09 | 3712.57 | 01-NOV-09:09 | 1343.25 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4721.78 | 18-NOV-13:00 | 798.25 | 26-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 3712.57 | 01-DEC-10:09 | 1343.25 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4142.16 | 07-DEC-14:00 | 529.89 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4142.16 | 76.50 | |||||
Maximum of Months | 2879.63 | 3712.57 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 6164.38 | 823.01 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.18 | 04-JAN-13:00 | 199.72 | 15-JAN-09:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.94 | 28-FEB-15:00 | 146.27 | 21-FEB-10:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.80 | 21-MAR-13:00 | 35.94 | 14-MAR-22:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.41 | 01-APR-14:00 | 267.53 | 14-APR-16:00 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.11 | 06-MAY-13:00 | 132.65 | 21-MAY-13:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.05 | 13-JUN-15:00 | 183.40 | 25-JUN-19:00 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.16 | 15-JUL-16:00 | 360.95 | 16-JUL-17:00 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.92 | 27-AUG-14:00 | 469.35 | 20-AUG-11:10 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.49 | 06-SEP-14:00 | 374.07 | 03-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.58 | 04-OCT-14:00 | 290.16 | 29-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.29 | 18-NOV-13:00 | 439.16 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.41 | 07-DEC-14:00 | 291.18 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.41 | 35.94 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.11 | 469.35 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.18 | 04-JAN-13:00 | 198.44 | 15-JAN-09:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.94 | 28-FEB-15:00 | 146.27 | 21-FEB-10:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.80 | 21-MAR-13:00 | 35.61 | 14-MAR-22:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.40 | 01-APR-14:00 | 267.53 | 14-APR-16:00 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.11 | 06-MAY-13:00 | 132.66 | 21-MAY-13:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.06 | 13-JUN-15:00 | 182.40 | 25-JUN-19:00 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.16 | 15-JUL-16:00 | 357.31 | 16-JUL-17:00 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.92 | 27-AUG-14:00 | 469.35 | 20-AUG-11:10 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.49 | 06-SEP-14:00 | 370.79 | 03-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.58 | 04-OCT-14:00 | 286.04 | 29-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.28 | 18-NOV-13:00 | 434.91 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.41 | 07-DEC-14:00 | 288.22 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.41 | 35.61 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.11 | 469.35 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.18 | 04-JAN-13:00 | 198.26 | 24-JAN-09:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2901.94 | 28-FEB-15:00 | 146.27 | 21-FEB-10:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3224.81 | 21-MAR-13:00 | 35.19 | 14-MAR-22:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2979.41 | 01-APR-14:00 | 267.54 | 14-APR-16:00 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.11 | 06-MAY-13:00 | 132.66 | 21-MAY-13:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3133.07 | 13-JUN-15:00 | 182.90 | 25-JUN-19:00 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2402.16 | 15-JUL-16:00 | 359.94 | 16-JUL-17:00 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2634.92 | 27-AUG-14:00 | 469.35 | 20-AUG-11:10 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2627.50 | 06-SEP-14:00 | 374.08 | 03-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2377.58 | 04-OCT-14:00 | 286.54 | 29-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2695.28 | 18-NOV-13:00 | 430.79 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.41 | 07-DEC-14:00 | 281.17 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2364.41 | 35.19 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3517.11 | 469.35 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1856.29 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2727.55 | 04-JAN-13:00 | 456.33 | 07-JAN-05:00 |
February | 1439.81 | 04-FEB-15:09 | 1856.29 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2988.57 | 28-FEB-15:00 | 187.22 | 05-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1856.29 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3302.74 | 21-MAR-13:00 | 94.03 | 14-MAR-22:00 |
April | 1439.81 | 01-APR-14:09 | 1856.29 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3015.77 | 01-APR-14:00 | 271.45 | 14-APR-16:00 |
May | 1439.81 | 06-MAY-14:09 | 1856.29 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3585.38 | 06-MAY-13:00 | 195.66 | 08-MAY-22:00 |
June | 1439.81 | 03-JUN-14:09 | 1856.29 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3208.69 | 13-JUN-15:00 | 284.77 | 25-JUN-19:00 |
July | 1439.81 | 01-JUL-14:09 | 1856.29 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2440.66 | 28-JUL-13:00 | 457.51 | 16-JUL-17:00 |
August | 1439.81 | 05-AUG-14:09 | 1856.29 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2698.68 | 27-AUG-14:00 | 480.68 | 20-AUG-11:10 |
September | 1439.81 | 02-SEP-14:09 | 1856.29 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2678.53 | 06-SEP-14:00 | 488.91 | 03-SEP-17:00 |
October | 1439.81 | 07-OCT-14:09 | 1856.29 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2423.76 | 04-OCT-14:00 | 383.54 | 09-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1856.29 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2734.64 | 18-NOV-13:00 | 481.99 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1856.29 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2398.93 | 07-DEC-14:00 | 336.73 | 17-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2398.93 | 94.03 | |||||
Maximum of Months | 1439.81 | 1856.29 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 3585.38 | 488.91 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 34631.92 | 24-JAN-08:62 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 322.68 |
February | 33974.89 | 21-FEB-08:61 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 70.22 | 0.00 |
March | 31546.85 | 03-MAR-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 92.29 | 0.00 |
April | 28065.38 | 27-APR-07:01 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 103.17 | 0.00 |
May | 26109.48 | 09-MAY-07:01 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.06 |
June | 27123.11 | 25-JUN-07:01 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 19.55 | 0.00 |
July | 30637.92 | 09-JUL-07:01 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 72.88 | 0.00 |
August | 27474.76 | 24-AUG-07:02 | 1079.86 | 450.00 | 447.75 | 0.00 | 0.00 | 0.00 | 0.00 | 31.27 | 0.00 |
September | 28152.28 | 09-SEP-07:02 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 |
October | 27917.03 | 09-OCT-07:01 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 8.78 | 0.00 |
November | 32537.92 | 25-NOV-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196.68 |
December | 32227.72 | 27-DEC-08:62 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.58 |
Annual Sum or Average | |||||||||||
Minimum of Months | 26109.48 | 0.00 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 34631.92 | 1259.84 | 525.00 | 522.37 | 0.00 | 0.00 | 0.00 | 0.00 | 103.17 | 322.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 19614.43 | 24-JAN-08:62 | 449.94 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 179.31 |
February | 19451.66 | 24-FEB-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.81 |
March | 18408.05 | 03-MAR-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 52.32 | 0.00 |
April | 16657.70 | 23-APR-07:02 | 539.93 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 15.35 | 0.00 |
May | 16038.97 | 09-MAY-07:01 | 629.92 | 262.50 | 261.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.39 |
June | 16929.83 | 25-JUN-07:01 | 629.92 | 262.50 | 261.19 | 0.00 | 0.00 | 0.00 | 0.00 | 14.70 | 0.00 |
July | 17969.77 | 08-JUL-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.29 |
August | 16581.88 | 24-AUG-07:02 | 539.93 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 23.45 | 0.00 |
September | 16987.55 | 10-SEP-07:01 | 629.92 | 262.50 | 261.19 | 0.00 | 0.00 | 0.00 | 0.00 | 47.86 | 0.00 |
October | 17020.30 | 08-OCT-07:02 | 539.93 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 28.64 | 0.00 |
November | 18946.90 | 25-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.93 |
December | 18748.71 | 27-DEC-08:62 | 449.94 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.27 |
Annual Sum or Average | |||||||||||
Minimum of Months | 16038.97 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19614.43 | 629.92 | 262.50 | 261.19 | 0.00 | 0.00 | 0.00 | 0.00 | 52.32 | 179.31 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16705.87 | 24-JAN-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 |
February | 17388.08 | 25-FEB-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.71 |
March | 15793.42 | 04-MAR-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.36 | 0.00 |
April | 14060.03 | 27-APR-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 | 0.00 |
May | 12809.65 | 11-MAY-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 |
June | 12739.89 | 27-JUN-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.28 |
July | 14270.06 | 06-JUL-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.23 |
August | 13037.98 | 24-AUG-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
September | 12722.16 | 28-SEP-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 |
October | 12738.09 | 11-OCT-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.06 |
November | 15828.03 | 25-NOV-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.26 |
December | 17078.98 | 21-DEC-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.96 |
Annual Sum or Average | |||||||||||
Minimum of Months | 12722.16 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17388.08 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 | 13.96 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16777.74 | 24-JAN-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.19 |
February | 17467.88 | 25-FEB-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.72 |
March | 15851.28 | 04-MAR-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.31 | 0.00 |
April | 14140.30 | 27-APR-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 | 0.00 |
May | 12884.06 | 11-MAY-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.92 |
June | 12849.60 | 20-JUN-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.18 |
July | 14365.24 | 06-JUL-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.25 |
August | 13090.46 | 24-AUG-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
September | 12790.84 | 28-SEP-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.75 |
October | 12824.80 | 11-OCT-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.10 |
November | 15896.01 | 25-NOV-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.31 |
December | 17123.76 | 21-DEC-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.95 |
Annual Sum or Average | |||||||||||
Minimum of Months | 12790.84 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17467.88 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 | 13.95 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16536.18 | 24-JAN-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.09 |
February | 17196.60 | 25-FEB-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.68 |
March | 15590.37 | 04-MAR-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.75 | 0.00 |
April | 13865.42 | 27-APR-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.51 | 0.00 |
May | 12633.11 | 11-MAY-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.84 |
June | 12624.64 | 20-JUN-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.97 |
July | 14113.26 | 06-JUL-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.20 |
August | 12821.87 | 24-AUG-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 |
September | 12526.20 | 28-SEP-06:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 |
October | 12591.98 | 11-OCT-06:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.01 |
November | 15651.06 | 25-NOV-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.12 |
December | 16139.48 | 27-DEC-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.88 |
Annual Sum or Average | |||||||||||
Minimum of Months | 12526.20 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17196.60 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.75 | 7.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 30393.31 | 24-JAN-08:62 | 0.00 | 375.00 | 368.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 324.25 |
February | 30526.30 | 23-FEB-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.71 |
March | 28341.82 | 03-MAR-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 89.38 | 0.00 |
April | 25435.35 | 27-APR-07:01 | 0.00 | 525.00 | 515.47 | 0.00 | 0.00 | 0.00 | 0.00 | 108.55 | 0.00 |
May | 23921.15 | 09-MAY-07:01 | 0.00 | 525.00 | 515.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.04 |
June | 25001.62 | 20-JUN-07:01 | 0.00 | 525.00 | 515.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.15 |
July | 26819.33 | 06-JUL-07:01 | 0.00 | 525.00 | 515.47 | 0.00 | 0.00 | 0.00 | 0.00 | 27.52 | 0.00 |
August | 23822.33 | 30-AUG-07:02 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 26.26 | 0.00 |
September | 24012.19 | 06-SEP-07:01 | 0.00 | 525.00 | 515.47 | 0.00 | 0.00 | 0.00 | 0.00 | 97.82 | 0.00 |
October | 24549.39 | 11-OCT-07:02 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.79 |
November | 28571.78 | 25-NOV-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 192.29 |
December | 29566.92 | 21-DEC-08:62 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 23822.33 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 30526.30 | 0.00 | 525.00 | 515.47 | 0.00 | 0.00 | 0.00 | 0.00 | 108.55 | 324.25 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 15862.24 | 24-JAN-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 180.09 |
February | 15951.57 | 23-FEB-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.82 |
March | 14794.40 | 03-MAR-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 55.17 | 0.00 |
April | 13331.31 | 27-APR-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 65.67 | 0.00 |
May | 12522.22 | 09-MAY-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.90 |
June | 13088.08 | 20-JUN-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.28 |
July | 14046.95 | 06-JUL-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 19.60 | 0.00 |
August | 12477.23 | 29-AUG-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 23.18 | 0.00 |
September | 12601.37 | 06-SEP-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 59.32 | 0.00 |
October | 12870.00 | 11-OCT-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.32 |
November | 14909.41 | 25-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 104.72 |
December | 15386.28 | 27-DEC-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.01 |
Annual Sum or Average | |||||||||||
Minimum of Months | 12477.23 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15951.57 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 65.67 | 180.09 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 15755.58 | 24-JAN-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 179.22 |
February | 15839.66 | 23-FEB-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.93 |
March | 14691.68 | 03-MAR-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 56.04 | 0.00 |
April | 13230.69 | 27-APR-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 66.50 | 0.00 |
May | 12430.81 | 09-MAY-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.16 |
June | 12991.54 | 20-JUN-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.65 |
July | 13944.26 | 06-JUL-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 20.29 | 0.00 |
August | 12380.63 | 29-AUG-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 23.84 | 0.00 |
September | 12511.33 | 06-SEP-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 59.73 | 0.00 |
October | 12772.01 | 11-OCT-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.73 |
November | 14802.62 | 25-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.77 |
December | 15278.62 | 27-DEC-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.10 |
Annual Sum or Average | |||||||||||
Minimum of Months | 12380.63 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15839.66 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 66.50 | 179.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 15738.76 | 24-JAN-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.33 |
February | 15859.51 | 23-FEB-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.27 |
March | 14685.70 | 03-MAR-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 58.48 | 0.00 |
April | 13239.77 | 27-APR-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 68.33 | 0.00 |
May | 12445.31 | 09-MAY-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.45 |
June | 13028.36 | 20-JUN-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.53 |
July | 13966.35 | 06-JUL-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 21.72 | 0.00 |
August | 12416.88 | 29-AUG-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 24.85 | 0.00 |
September | 12553.99 | 06-SEP-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 60.52 | 0.00 |
October | 12762.85 | 11-OCT-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.36 |
November | 14799.31 | 25-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.53 |
December | 15269.23 | 27-DEC-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.40 |
Annual Sum or Average | |||||||||||
Minimum of Months | 12416.88 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 15859.51 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 68.33 | 176.33 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 17271.66 | 24-JAN-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.76 |
February | 17919.62 | 23-FEB-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.52 |
March | 15816.68 | 03-MAR-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 63.28 | 0.00 |
April | 13943.07 | 27-APR-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 65.14 | 0.00 |
May | 13173.65 | 11-MAY-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 51.16 | 0.00 |
June | 14090.20 | 20-JUN-07:01 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.11 |
July | 15752.97 | 11-JUL-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.09 |
August | 13707.52 | 24-AUG-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 28.70 | 0.00 |
September | 13905.14 | 12-SEP-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 27.57 | 0.00 |
October | 13975.24 | 11-OCT-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.60 |
November | 16250.63 | 25-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.08 |
December | 16575.03 | 27-DEC-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.65 |
Annual Sum or Average | |||||||||||
Minimum of Months | 13173.65 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17919.62 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 65.14 | 178.76 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.118298E+12 | 108067.68 | 12-JAN-13:50 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 0.111438E+12 | 117163.98 | 13-FEB-15:20 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 0.127934E+12 | 117224.46 | 27-MAR-13:50 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 0.129908E+12 | 119912.53 | 02-APR-14:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 0.140474E+12 | 129311.07 | 06-MAY-13:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 0.138988E+12 | 136761.97 | 13-JUN-13:50 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.123445E+12 | 109191.30 | 21-JUL-13:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.132800E+12 | 126823.42 | 13-AUG-13:39 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.126439E+12 | 121109.84 | 30-SEP-11:39 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.125155E+12 | 115668.38 | 16-OCT-14:20 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 0.118767E+12 | 111105.67 | 18-NOV-13:20 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 0.118048E+12 | 106384.72 | 30-DEC-13:39 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.151169E+13 | 0.00 | ||||
Minimum of Months | 0.111438E+12 | 106384.72 | 0.00 | 0.00 | ||
Maximum of Months | 0.140474E+12 | 136761.97 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.381118E+11 | 0.540232E+10 | 0.108325E+11 | 0.00 | 0.883342E+10 | 0.00 | 0.00 | 0.502066E+11 | 0.00 | 0.00 | 0.00 | 0.491165E+10 | 0.00 |
February | 0.345095E+11 | 0.477164E+10 | 0.980803E+10 | 0.00 | 0.850961E+10 | 0.00 | 0.00 | 0.493992E+11 | 0.00 | 0.00 | 0.00 | 0.444010E+10 | 0.00 |
March | 0.387104E+11 | 0.505186E+10 | 0.110038E+11 | 0.00 | 0.976462E+10 | 0.00 | 0.00 | 0.584781E+11 | 0.00 | 0.00 | 0.00 | 0.492537E+10 | 0.00 |
April | 0.369865E+11 | 0.472153E+10 | 0.105115E+11 | 0.00 | 0.101527E+11 | 0.00 | 0.00 | 0.628121E+11 | 0.00 | 0.00 | 0.00 | 0.472330E+10 | 0.00 |
May | 0.383972E+11 | 0.475707E+10 | 0.109147E+11 | 0.00 | 0.113193E+11 | 0.00 | 0.00 | 0.702195E+11 | 0.00 | 0.00 | 0.00 | 0.486580E+10 | 0.00 |
June | 0.374142E+11 | 0.452501E+10 | 0.106349E+11 | 0.00 | 0.113759E+11 | 0.00 | 0.00 | 0.703300E+11 | 0.00 | 0.00 | 0.00 | 0.470763E+10 | 0.00 |
July | 0.379970E+11 | 0.473087E+10 | 0.107982E+11 | 0.00 | 0.943286E+10 | 0.00 | 0.00 | 0.556494E+11 | 0.00 | 0.00 | 0.00 | 0.483709E+10 | 0.00 |
August | 0.386827E+11 | 0.481930E+10 | 0.109970E+11 | 0.00 | 0.104479E+11 | 0.00 | 0.00 | 0.629822E+11 | 0.00 | 0.00 | 0.00 | 0.487094E+10 | 0.00 |
September | 0.370138E+11 | 0.483945E+10 | 0.105184E+11 | 0.00 | 0.989923E+10 | 0.00 | 0.00 | 0.594561E+11 | 0.00 | 0.00 | 0.00 | 0.471174E+10 | 0.00 |
October | 0.381120E+11 | 0.518942E+10 | 0.108325E+11 | 0.00 | 0.960810E+10 | 0.00 | 0.00 | 0.565334E+11 | 0.00 | 0.00 | 0.00 | 0.487951E+10 | 0.00 |
November | 0.369307E+11 | 0.521636E+10 | 0.104978E+11 | 0.00 | 0.896276E+10 | 0.00 | 0.00 | 0.524177E+11 | 0.00 | 0.00 | 0.00 | 0.474117E+10 | 0.00 |
December | 0.380245E+11 | 0.545322E+10 | 0.108050E+11 | 0.00 | 0.878637E+10 | 0.00 | 0.00 | 0.500704E+11 | 0.00 | 0.00 | 0.00 | 0.490892E+10 | 0.00 |
Annual Sum or Average | 0.450890E+12 | 0.594780E+11 | 0.128154E+12 | 0.117093E+12 | 0.00 | 0.698555E+12 | 0.575232E+11 | ||||||
Minimum of Months | 0.345095E+11 | 0.452501E+10 | 0.980803E+10 | 0.00 | 0.850961E+10 | 0.00 | 0.00 | 0.493992E+11 | 0.00 | 0.00 | 0.00 | 0.444010E+10 | 0.00 |
Maximum of Months | 0.387104E+11 | 0.545322E+10 | 0.110038E+11 | 0.00 | 0.113759E+11 | 0.00 | 0.00 | 0.703300E+11 | 0.00 | 0.00 | 0.00 | 0.492537E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 29013.96 | 01-JAN-11:09 | 5459.01 | 01-JAN-06:10 | 8059.50 | 01-JAN-11:09 | 0.00 | 8571.03 | 12-JAN-13:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 29013.96 | 01-FEB-10:09 | 5459.01 | 01-FEB-06:10 | 8059.50 | 01-FEB-10:09 | 0.00 | 9575.74 | 15-FEB-13:00 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 29013.96 | 01-MAR-10:09 | 5459.01 | 01-MAR-06:10 | 8059.50 | 01-MAR-10:09 | 0.00 | 10081.53 | 27-MAR-12:00 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 29013.96 | 01-APR-09:09 | 5459.01 | 01-APR-05:10 | 8059.50 | 01-APR-09:09 | 0.00 | 10848.94 | 02-APR-14:00 | 0.00 | 0.00 | 01-APR-00:10 |
May | 29013.96 | 01-MAY-09:09 | 5459.01 | 01-MAY-05:10 | 8059.50 | 01-MAY-09:09 | 0.00 | 12307.02 | 04-MAY-12:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 29013.96 | 01-JUN-09:09 | 5459.01 | 01-JUN-05:10 | 8059.50 | 01-JUN-09:09 | 0.00 | 12687.72 | 16-JUN-12:00 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 29013.96 | 01-JUL-09:09 | 5459.01 | 01-JUL-05:10 | 8059.50 | 01-JUL-09:09 | 0.00 | 9350.14 | 28-JUL-12:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 29013.96 | 01-AUG-09:09 | 5459.01 | 01-AUG-05:10 | 8059.50 | 01-AUG-09:09 | 0.00 | 11901.58 | 13-AUG-14:30 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 29013.96 | 01-SEP-09:09 | 5459.01 | 01-SEP-05:10 | 8059.50 | 01-SEP-09:09 | 0.00 | 11021.36 | 30-SEP-11:39 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 29013.96 | 01-OCT-10:09 | 5459.01 | 01-OCT-05:10 | 8059.50 | 01-OCT-10:09 | 0.00 | 9940.67 | 28-OCT-12:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 29013.96 | 01-NOV-09:09 | 5459.01 | 01-NOV-05:10 | 8059.50 | 01-NOV-09:09 | 0.00 | 9450.55 | 10-NOV-13:39 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 29013.96 | 01-DEC-10:09 | 5459.01 | 01-DEC-17:30 | 8059.50 | 01-DEC-10:09 | 0.00 | 8779.67 | 30-DEC-13:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 29013.96 | 5459.01 | 8059.50 | 0.00 | 8571.03 | 0.00 | 0.00 | |||||
Maximum of Months | 29013.96 | 5459.01 | 8059.50 | 0.00 | 12687.72 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 55028.78 | 12-JAN-13:09 | 0.00 | 0.00 | 0.00 | 11769.75 | 02-JAN-13:20 | 0.00 |
February | 61382.82 | 15-FEB-13:00 | 0.00 | 0.00 | 0.00 | 9961.90 | 13-FEB-15:20 | 0.00 |
March | 64076.74 | 27-MAR-12:00 | 0.00 | 0.00 | 0.00 | 8638.42 | 24-MAR-13:39 | 0.00 |
April | 68678.47 | 02-APR-14:00 | 0.00 | 0.00 | 0.00 | 7542.60 | 17-APR-12:30 | 0.00 |
May | 77461.74 | 04-MAY-12:00 | 0.00 | 0.00 | 0.00 | 9272.37 | 23-MAY-12:00 | 0.00 |
June | 78998.67 | 16-JUN-12:00 | 0.00 | 0.00 | 0.00 | 9649.30 | 26-JUN-12:30 | 0.00 |
July | 59510.92 | 28-JUL-12:00 | 0.00 | 0.00 | 0.00 | 9649.01 | 13-JUL-12:09 | 0.00 |
August | 72984.77 | 13-AUG-14:30 | 0.00 | 0.00 | 0.00 | 9649.34 | 07-AUG-12:30 | 0.00 |
September | 67589.71 | 30-SEP-11:39 | 0.00 | 0.00 | 0.00 | 9652.05 | 26-SEP-12:39 | 0.00 |
October | 62339.78 | 28-OCT-12:00 | 0.00 | 0.00 | 0.00 | 9609.26 | 15-OCT-16:40 | 0.00 |
November | 59734.46 | 18-NOV-12:00 | 0.00 | 0.00 | 0.00 | 9303.92 | 03-NOV-14:09 | 0.00 |
December | 55932.86 | 30-DEC-13:00 | 0.00 | 0.00 | 0.00 | 7547.22 | 22-DEC-13:30 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 55028.78 | 0.00 | 0.00 | 0.00 | 7542.60 | 0.00 | ||
Maximum of Months | 78998.67 | 0.00 | 0.00 | 0.00 | 11769.75 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 108067.68 | 12-JAN-13:50 | 29013.96 | 8059.50 | 0.00 | 0.00 | 8205.92 | 0.00 | 0.00 | 52614.85 | 0.00 |
February | 117163.98 | 13-FEB-15:20 | 29013.96 | 8059.50 | 0.00 | 0.00 | 9458.12 | 0.00 | 0.00 | 60670.50 | 0.00 |
March | 117224.46 | 27-MAR-13:50 | 29013.96 | 8059.50 | 0.00 | 0.00 | 9846.85 | 0.00 | 0.00 | 62762.03 | 0.00 |
April | 119912.53 | 02-APR-14:00 | 29013.96 | 8059.50 | 0.00 | 0.00 | 10848.94 | 0.00 | 0.00 | 68678.47 | 0.00 |
May | 129311.07 | 06-MAY-13:00 | 29013.96 | 8059.50 | 0.00 | 0.00 | 11732.62 | 0.00 | 0.00 | 75075.19 | 0.00 |
June | 136761.97 | 13-JUN-13:50 | 29013.96 | 8059.50 | 0.00 | 0.00 | 12443.56 | 0.00 | 0.00 | 77597.70 | 0.00 |
July | 109191.30 | 21-JUL-13:00 | 29013.96 | 8059.50 | 0.00 | 0.00 | 9046.44 | 0.00 | 0.00 | 57642.13 | 0.00 |
August | 126823.42 | 13-AUG-13:39 | 29013.96 | 8059.50 | 0.00 | 0.00 | 11812.17 | 0.00 | 0.00 | 72529.14 | 0.00 |
September | 121109.84 | 30-SEP-11:39 | 29013.96 | 8059.50 | 0.00 | 0.00 | 11021.36 | 0.00 | 0.00 | 67589.71 | 0.00 |
October | 115668.38 | 16-OCT-14:20 | 29013.96 | 8059.50 | 0.00 | 0.00 | 9877.97 | 0.00 | 0.00 | 61184.48 | 0.00 |
November | 111105.67 | 18-NOV-13:20 | 29013.96 | 8059.50 | 0.00 | 0.00 | 8936.50 | 0.00 | 0.00 | 57549.75 | 0.00 |
December | 106384.72 | 30-DEC-13:39 | 29013.96 | 8059.50 | 0.00 | 0.00 | 8705.97 | 0.00 | 0.00 | 55523.17 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 106384.72 | 29013.96 | 8059.50 | 0.00 | 0.00 | 8205.92 | 0.00 | 0.00 | 52614.85 | 0.00 | |
Maximum of Months | 136761.97 | 29013.96 | 8059.50 | 0.00 | 0.00 | 12443.56 | 0.00 | 0.00 | 77597.70 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.53 | 1.33 | 24.51 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.53 | 1.67 | 24.52 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 4.17 | 24.53 | 3.00 | 24.52 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.53 | 1.67 | 24.52 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.55 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.68 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.65 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.57 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.59 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 7.67 | 24.62 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.68 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.49 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.59 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.70 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 24.61 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.47 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 24.55 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.63 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.46 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 8.33 | 24.61 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 24.70 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.46 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.55 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.66 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.62 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.56 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.58 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 6.83 | 24.61 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.66 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.54 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.50 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.70 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 24.88 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 24.74 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.51 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.68 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.60 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.54 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.56 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.53 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 10.17 | 24.70 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 24.88 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.49 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.68 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.83 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.70 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.72 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.63 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.51 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.51 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.59 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 9.17 | 24.68 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 24.83 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.49 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.67 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.85 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.74 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.51 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.72 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.63 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.51 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.58 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 8.83 | 24.69 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 24.85 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.46 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.47 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.63 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.81 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 24.68 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.70 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.61 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.48 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.49 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.56 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 7.83 | 24.66 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 24.81 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.55 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.55 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.75 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 24.97 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 24.83 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.49 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.80 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.65 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.56 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.50 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.60 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 11.67 | 24.76 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 24.97 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 14.00 | 23.91 | 496.00 | 23.89 | 14.00 | 23.91 |
February | 5.50 | 23.93 | 448.00 | 23.89 | 5.50 | 23.93 |
March | 27.00 | 23.93 | 496.00 | 23.89 | 27.00 | 23.93 |
April | 100.83 | 23.90 | 480.00 | 23.89 | 100.83 | 23.90 |
May | 247.00 | 23.90 | 496.00 | 23.89 | 247.00 | 23.90 |
June | 249.50 | 23.89 | 480.00 | 23.89 | 249.50 | 23.89 |
July | 86.00 | 23.89 | 496.00 | 23.89 | 86.00 | 23.89 |
August | 306.33 | 23.89 | 496.00 | 23.89 | 306.33 | 23.89 |
September | 246.17 | 23.89 | 480.00 | 23.89 | 246.17 | 23.89 |
October | 262.33 | 23.89 | 496.00 | 23.89 | 262.33 | 23.89 |
November | 126.00 | 23.90 | 480.00 | 23.89 | 126.00 | 23.90 |
December | 48.83 | 23.90 | 496.00 | 23.89 | 48.83 | 23.90 |
Annual Sum or Average | 1719.50 | 23.89 | 5840.00 | 23.89 | 1719.50 | 23.89 |
Minimum of Months | 5.50 | 23.89 | 448.00 | 23.89 | 5.50 | 23.89 |
Maximum of Months | 306.33 | 23.93 | 496.00 | 23.89 | 306.33 | 23.93 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.00 | 23.89 | 495.33 | 23.89 | 3.00 | 23.89 |
February | 2.17 | 23.89 | 448.00 | 23.89 | 2.17 | 23.89 |
March | 1.67 | 23.89 | 496.00 | 23.89 | 1.67 | 23.89 |
April | 69.50 | 23.89 | 480.00 | 23.89 | 69.50 | 23.89 |
May | 221.00 | 23.89 | 496.00 | 23.89 | 221.00 | 23.89 |
June | 235.50 | 23.89 | 480.00 | 23.89 | 235.50 | 23.89 |
July | 67.00 | 23.89 | 496.00 | 23.89 | 67.00 | 23.89 |
August | 278.33 | 23.89 | 496.00 | 23.89 | 278.33 | 23.89 |
September | 220.83 | 23.89 | 480.00 | 23.89 | 220.83 | 23.89 |
October | 222.83 | 23.89 | 496.00 | 23.89 | 222.83 | 23.89 |
November | 102.83 | 23.89 | 480.00 | 23.89 | 102.83 | 23.89 |
December | 31.00 | 23.89 | 495.00 | 23.89 | 31.00 | 23.89 |
Annual Sum or Average | 1455.67 | 23.89 | 5838.33 | 23.89 | 1455.67 | 23.89 |
Minimum of Months | 1.67 | 23.89 | 448.00 | 23.89 | 1.67 | 23.89 |
Maximum of Months | 278.33 | 23.89 | 496.00 | 23.89 | 278.33 | 23.89 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 24.00 | 25.18 | 371.00 | 24.08 | 24.00 | 25.18 |
February | 20.67 | 25.23 | 336.00 | 24.09 | 20.67 | 25.23 |
March | 28.50 | 25.27 | 379.00 | 24.09 | 28.50 | 25.27 |
April | 110.83 | 24.50 | 360.00 | 24.12 | 110.83 | 24.50 |
May | 240.83 | 24.20 | 375.00 | 24.10 | 240.83 | 24.20 |
June | 253.33 | 24.18 | 366.00 | 24.11 | 253.33 | 24.18 |
July | 120.17 | 24.39 | 369.00 | 24.10 | 120.17 | 24.39 |
August | 307.17 | 24.10 | 379.00 | 24.08 | 307.17 | 24.10 |
September | 251.67 | 24.15 | 360.00 | 24.09 | 251.67 | 24.15 |
October | 259.50 | 24.14 | 371.00 | 24.08 | 259.50 | 24.14 |
November | 145.83 | 24.27 | 360.00 | 24.07 | 145.83 | 24.27 |
December | 63.67 | 24.57 | 369.00 | 24.07 | 63.67 | 24.57 |
Annual Sum or Average | 1826.17 | 24.26 | 4395.00 | 24.09 | 1826.17 | 24.26 |
Minimum of Months | 20.67 | 24.10 | 336.00 | 24.07 | 20.67 | 24.10 |
Maximum of Months | 307.17 | 25.27 | 379.00 | 24.12 | 307.17 | 25.27 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 24.00 | 25.18 | 371.00 | 24.08 | 24.00 | 25.18 |
February | 19.83 | 25.26 | 336.00 | 24.09 | 19.83 | 25.26 |
March | 28.00 | 25.30 | 379.00 | 24.09 | 28.00 | 25.30 |
April | 109.83 | 24.51 | 360.00 | 24.12 | 109.83 | 24.51 |
May | 237.17 | 24.21 | 375.00 | 24.10 | 237.17 | 24.21 |
June | 249.67 | 24.18 | 366.00 | 24.11 | 249.67 | 24.18 |
July | 118.17 | 24.40 | 369.00 | 24.10 | 118.17 | 24.40 |
August | 305.33 | 24.10 | 379.00 | 24.08 | 305.33 | 24.10 |
September | 249.83 | 24.15 | 360.00 | 24.09 | 249.83 | 24.15 |
October | 257.83 | 24.14 | 371.00 | 24.08 | 257.83 | 24.14 |
November | 145.67 | 24.27 | 360.00 | 24.07 | 145.67 | 24.27 |
December | 63.67 | 24.58 | 369.00 | 24.07 | 63.67 | 24.58 |
Annual Sum or Average | 1809.00 | 24.26 | 4395.00 | 24.09 | 1809.00 | 24.26 |
Minimum of Months | 19.83 | 24.10 | 336.00 | 24.07 | 19.83 | 24.10 |
Maximum of Months | 305.33 | 25.30 | 379.00 | 24.12 | 305.33 | 25.30 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 26.17 | 25.07 | 371.00 | 24.08 | 26.17 | 25.07 |
February | 23.67 | 25.05 | 336.00 | 24.09 | 23.67 | 25.05 |
March | 31.00 | 25.15 | 379.00 | 24.09 | 31.00 | 25.15 |
April | 117.00 | 24.46 | 360.00 | 24.11 | 117.00 | 24.46 |
May | 244.67 | 24.20 | 375.00 | 24.10 | 244.67 | 24.20 |
June | 260.17 | 24.17 | 366.00 | 24.10 | 260.17 | 24.17 |
July | 126.67 | 24.36 | 369.00 | 24.10 | 126.67 | 24.36 |
August | 314.33 | 24.10 | 379.00 | 24.07 | 314.33 | 24.10 |
September | 262.33 | 24.14 | 360.00 | 24.08 | 262.33 | 24.14 |
October | 266.83 | 24.13 | 371.00 | 24.07 | 266.83 | 24.13 |
November | 157.33 | 24.25 | 360.00 | 24.07 | 157.33 | 24.25 |
December | 67.33 | 24.54 | 369.00 | 24.07 | 67.33 | 24.54 |
Annual Sum or Average | 1897.50 | 24.24 | 4395.00 | 24.09 | 1897.50 | 24.24 |
Minimum of Months | 23.67 | 24.10 | 336.00 | 24.07 | 23.67 | 24.10 |
Maximum of Months | 314.33 | 25.15 | 379.00 | 24.11 | 314.33 | 25.15 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 22.50 | 24.59 | 340.00 | 23.96 | 22.50 | 24.59 |
February | 28.83 | 24.52 | 308.00 | 23.97 | 28.83 | 24.52 |
March | 23.00 | 24.72 | 348.00 | 23.95 | 23.00 | 24.72 |
April | 143.83 | 24.09 | 330.00 | 23.98 | 143.83 | 24.09 |
May | 267.50 | 23.99 | 344.00 | 23.97 | 267.50 | 23.99 |
June | 280.67 | 23.98 | 336.00 | 23.96 | 280.67 | 23.98 |
July | 151.17 | 24.08 | 338.00 | 23.98 | 151.17 | 24.08 |
August | 326.33 | 23.95 | 348.00 | 23.94 | 326.33 | 23.95 |
September | 289.83 | 23.98 | 330.00 | 23.97 | 289.83 | 23.98 |
October | 300.50 | 23.97 | 340.00 | 23.96 | 300.50 | 23.97 |
November | 191.50 | 23.99 | 330.00 | 23.95 | 191.50 | 23.99 |
December | 68.00 | 24.23 | 338.00 | 23.96 | 68.00 | 24.23 |
Annual Sum or Average | 2093.67 | 24.02 | 4030.00 | 23.96 | 2093.67 | 24.02 |
Minimum of Months | 22.50 | 23.95 | 308.00 | 23.94 | 22.50 | 23.95 |
Maximum of Months | 326.33 | 24.72 | 348.00 | 23.98 | 326.33 | 24.72 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 25.67 | 24.50 | 340.00 | 23.96 | 25.67 | 24.50 |
February | 31.33 | 24.48 | 308.00 | 23.96 | 31.33 | 24.48 |
March | 25.33 | 24.64 | 348.00 | 23.95 | 25.33 | 24.64 |
April | 156.50 | 24.07 | 330.00 | 23.98 | 156.50 | 24.07 |
May | 275.50 | 23.99 | 344.00 | 23.97 | 275.50 | 23.99 |
June | 284.50 | 23.97 | 336.00 | 23.96 | 284.50 | 23.97 |
July | 161.17 | 24.07 | 338.00 | 23.98 | 161.17 | 24.07 |
August | 328.33 | 23.95 | 348.00 | 23.94 | 328.33 | 23.95 |
September | 293.83 | 23.97 | 330.00 | 23.96 | 293.83 | 23.97 |
October | 304.17 | 23.97 | 340.00 | 23.96 | 304.17 | 23.97 |
November | 199.17 | 23.98 | 330.00 | 23.95 | 199.17 | 23.98 |
December | 73.00 | 24.20 | 338.00 | 23.96 | 73.00 | 24.20 |
Annual Sum or Average | 2158.50 | 24.01 | 4030.00 | 23.96 | 2158.50 | 24.01 |
Minimum of Months | 25.33 | 23.95 | 308.00 | 23.94 | 25.33 | 23.95 |
Maximum of Months | 328.33 | 24.64 | 348.00 | 23.98 | 328.33 | 24.64 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 26.67 | 24.48 | 340.00 | 23.96 | 26.67 | 24.48 |
February | 32.50 | 24.46 | 308.00 | 23.96 | 32.50 | 24.46 |
March | 26.67 | 24.60 | 348.00 | 23.95 | 26.67 | 24.60 |
April | 158.67 | 24.06 | 330.00 | 23.98 | 158.67 | 24.06 |
May | 277.50 | 23.99 | 344.00 | 23.97 | 277.50 | 23.99 |
June | 287.33 | 23.97 | 336.00 | 23.96 | 287.33 | 23.97 |
July | 165.17 | 24.06 | 338.00 | 23.98 | 165.17 | 24.06 |
August | 329.50 | 23.95 | 348.00 | 23.94 | 329.50 | 23.95 |
September | 296.00 | 23.97 | 330.00 | 23.96 | 296.00 | 23.97 |
October | 306.33 | 23.97 | 340.00 | 23.96 | 306.33 | 23.97 |
November | 203.00 | 23.98 | 330.00 | 23.95 | 203.00 | 23.98 |
December | 76.17 | 24.19 | 338.00 | 23.96 | 76.17 | 24.19 |
Annual Sum or Average | 2185.50 | 24.01 | 4030.00 | 23.96 | 2185.50 | 24.01 |
Minimum of Months | 26.67 | 23.95 | 308.00 | 23.94 | 26.67 | 23.95 |
Maximum of Months | 329.50 | 24.60 | 348.00 | 23.98 | 329.50 | 24.60 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 27.00 | 24.47 | 340.00 | 23.96 | 27.00 | 24.47 |
February | 32.33 | 24.46 | 308.00 | 23.96 | 32.33 | 24.46 |
March | 27.00 | 24.59 | 348.00 | 23.95 | 27.00 | 24.59 |
April | 156.50 | 24.07 | 330.00 | 23.98 | 156.50 | 24.07 |
May | 275.17 | 23.99 | 344.00 | 23.97 | 275.17 | 23.99 |
June | 283.83 | 23.97 | 336.00 | 23.96 | 283.83 | 23.97 |
July | 163.17 | 24.07 | 338.00 | 23.98 | 163.17 | 24.07 |
August | 328.00 | 23.95 | 348.00 | 23.94 | 328.00 | 23.95 |
September | 293.33 | 23.97 | 330.00 | 23.96 | 293.33 | 23.97 |
October | 305.67 | 23.97 | 340.00 | 23.96 | 305.67 | 23.97 |
November | 203.33 | 23.98 | 330.00 | 23.95 | 203.33 | 23.98 |
December | 77.50 | 24.18 | 338.00 | 23.96 | 77.50 | 24.18 |
Annual Sum or Average | 2172.83 | 24.01 | 4030.00 | 23.96 | 2172.83 | 24.01 |
Minimum of Months | 27.00 | 23.95 | 308.00 | 23.94 | 27.00 | 23.95 |
Maximum of Months | 328.00 | 24.59 | 348.00 | 23.98 | 328.00 | 24.59 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 17.50 | 24.96 | 340.00 | 23.97 | 17.50 | 24.96 |
February | 14.67 | 25.13 | 308.00 | 23.97 | 14.67 | 25.13 |
March | 17.33 | 25.02 | 348.00 | 23.96 | 17.33 | 25.02 |
April | 84.33 | 24.25 | 330.00 | 23.98 | 84.33 | 24.25 |
May | 206.67 | 24.03 | 344.00 | 23.98 | 206.67 | 24.03 |
June | 214.17 | 24.01 | 336.00 | 23.97 | 214.17 | 24.01 |
July | 95.83 | 24.20 | 338.00 | 23.99 | 95.83 | 24.20 |
August | 282.17 | 23.96 | 348.00 | 23.95 | 282.17 | 23.96 |
September | 229.67 | 24.01 | 330.00 | 23.97 | 229.67 | 24.01 |
October | 248.17 | 23.99 | 340.00 | 23.97 | 248.17 | 23.99 |
November | 145.17 | 24.03 | 330.00 | 23.95 | 145.17 | 24.03 |
December | 53.67 | 24.34 | 338.00 | 23.97 | 53.67 | 24.34 |
Annual Sum or Average | 1609.33 | 24.07 | 4030.00 | 23.97 | 1609.33 | 24.07 |
Minimum of Months | 14.67 | 23.96 | 308.00 | 23.95 | 14.67 | 23.96 |
Maximum of Months | 282.17 | 25.13 | 348.00 | 23.99 | 282.17 | 25.13 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 23.90330 | 56.36970 | 0.62443 | 13.23625 |
February | 448.00000 | 23.90390 | 56.47541 | 0.63234 | 13.45856 |
March | 496.00000 | 23.90589 | 57.46333 | 0.64270 | 13.73969 |
April | 480.00000 | 23.90788 | 61.50638 | 0.67617 | 14.67070 |
May | 496.00000 | 23.91059 | 64.89170 | -0.1360 | 5.50571 |
June | 480.00000 | 23.90931 | 64.62099 | -0.1266 | 5.46934 |
July | 496.00000 | 23.90601 | 60.81710 | -0.1778 | 5.75405 |
August | 496.00000 | 23.90743 | 66.03499 | -0.1524 | 5.60399 |
September | 480.00000 | 23.90552 | 64.77149 | -0.1540 | 5.60388 |
October | 496.00000 | 23.90584 | 64.89484 | 0.67344 | 14.59355 |
November | 480.00000 | 23.90719 | 62.08302 | 0.65974 | 14.20496 |
December | 496.00000 | 23.90231 | 58.60927 | 0.63504 | 13.52366 |
Annual Sum or Average | 5840.00000 | 23.90627 | 61.56788 | 0.31440 | 10.42732 |
Minimum of Months | 448.00000 | 23.90231 | 56.36970 | -0.1778 | 5.46934 |
Maximum of Months | 496.00000 | 23.91059 | 66.03499 | 0.67617 | 14.67070 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 23.90363 | 54.22472 | 0.59005 | 12.37095 |
February | 448.00000 | 23.90400 | 54.56483 | 0.59666 | 12.54738 |
March | 496.00000 | 23.90523 | 55.70359 | 0.60540 | 12.76330 |
April | 480.00000 | 23.90710 | 59.75710 | 0.63812 | 13.62516 |
May | 496.00000 | 23.90915 | 63.06198 | -0.1824 | 5.81588 |
June | 480.00000 | 23.90775 | 62.91459 | -0.1754 | 5.78059 |
July | 496.00000 | 23.90546 | 58.84075 | -0.2230 | 6.15105 |
August | 496.00000 | 23.90637 | 63.97045 | -0.1964 | 5.93766 |
September | 480.00000 | 23.90455 | 62.69806 | -0.1997 | 5.96193 |
October | 496.00000 | 23.90522 | 62.45649 | 0.63889 | 13.66425 |
November | 480.00000 | 23.90689 | 59.76624 | 0.62492 | 13.28284 |
December | 496.00000 | 23.90251 | 56.16101 | 0.59962 | 12.62233 |
Annual Sum or Average | 5840.00000 | 23.90566 | 59.53119 | 0.27436 | 10.02721 |
Minimum of Months | 448.00000 | 23.90251 | 54.22472 | -0.2230 | 5.78059 |
Maximum of Months | 496.00000 | 23.90915 | 63.97045 | 0.63889 | 13.66425 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 24.04011 | 56.56915 | 0.64173 | 13.83825 |
February | 336.00000 | 24.04665 | 56.92181 | 0.64975 | 14.08269 |
March | 379.00000 | 24.04692 | 57.87357 | 0.65526 | 14.23927 |
April | 360.00000 | 24.06423 | 62.32010 | 0.69400 | 15.39955 |
May | 375.00000 | 24.05477 | 65.85898 | -0.1136 | 5.76080 |
June | 366.00000 | 24.05753 | 65.85653 | -0.1036 | 5.73037 |
July | 369.00000 | 24.05289 | 62.22943 | -0.1518 | 5.92571 |
August | 379.00000 | 24.03423 | 67.47163 | -0.1308 | 5.73047 |
September | 360.00000 | 24.04248 | 66.35462 | -0.1293 | 5.76121 |
October | 371.00000 | 24.03585 | 66.25151 | 0.69663 | 15.41090 |
November | 360.00000 | 24.02900 | 62.83303 | 0.67764 | 14.83763 |
December | 369.00000 | 24.02989 | 58.80603 | 0.65120 | 14.10048 |
Annual Sum or Average | 4395.00000 | 24.04451 | 62.48089 | 0.33325 | 10.86654 |
Minimum of Months | 336.00000 | 24.02900 | 56.56915 | -0.1518 | 5.73037 |
Maximum of Months | 379.00000 | 24.06423 | 67.47163 | 0.69663 | 15.41090 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 24.04015 | 56.52522 | 0.64224 | 13.85281 |
February | 336.00000 | 24.04674 | 56.87419 | 0.65037 | 14.10067 |
March | 379.00000 | 24.04702 | 57.82359 | 0.65589 | 14.25782 |
April | 360.00000 | 24.06446 | 62.24711 | 0.69478 | 15.42427 |
May | 375.00000 | 24.05508 | 65.76496 | -0.1121 | 5.75818 |
June | 366.00000 | 24.05784 | 65.76777 | -0.1021 | 5.72892 |
July | 369.00000 | 24.05313 | 62.14552 | -0.1505 | 5.92091 |
August | 379.00000 | 24.03428 | 67.42234 | -0.1300 | 5.72874 |
September | 360.00000 | 24.04260 | 66.29293 | -0.1283 | 5.75899 |
October | 371.00000 | 24.03591 | 66.19722 | 0.69708 | 15.42519 |
November | 360.00000 | 24.02894 | 62.80530 | 0.67794 | 14.84677 |
December | 369.00000 | 24.02984 | 58.78080 | 0.65148 | 14.10859 |
Annual Sum or Average | 4395.00000 | 24.04463 | 62.42252 | 0.33405 | 10.87433 |
Minimum of Months | 336.00000 | 24.02894 | 56.52522 | -0.1505 | 5.72874 |
Maximum of Months | 379.00000 | 24.06446 | 67.42234 | 0.69708 | 15.42519 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 24.03719 | 56.78506 | 0.63993 | 13.78228 |
February | 336.00000 | 24.04381 | 57.12792 | 0.64805 | 14.02896 |
March | 379.00000 | 24.04411 | 58.08258 | 0.65359 | 14.18612 |
April | 360.00000 | 24.06159 | 62.52642 | 0.69278 | 15.35636 |
May | 375.00000 | 24.05241 | 66.04516 | -0.1151 | 5.75582 |
June | 366.00000 | 24.05512 | 66.04692 | -0.1053 | 5.72471 |
July | 369.00000 | 24.05027 | 62.43713 | -0.1539 | 5.92524 |
August | 379.00000 | 24.03138 | 67.77271 | -0.1334 | 5.73140 |
September | 360.00000 | 24.03975 | 66.62565 | -0.1316 | 5.76060 |
October | 371.00000 | 24.03296 | 66.54462 | 0.69537 | 15.36659 |
November | 360.00000 | 24.02596 | 63.12332 | 0.67599 | 14.78284 |
December | 369.00000 | 24.02686 | 59.07053 | 0.64923 | 14.03956 |
Annual Sum or Average | 4395.00000 | 24.04175 | 62.71787 | 0.33146 | 10.83534 |
Minimum of Months | 336.00000 | 24.02596 | 56.78506 | -0.1539 | 5.72471 |
Maximum of Months | 379.00000 | 24.06159 | 67.77271 | 0.69537 | 15.36659 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.94623 | 58.04711 | 0.62297 | 13.24820 |
February | 308.00000 | 23.94835 | 58.50787 | 0.63149 | 13.49964 |
March | 348.00000 | 23.93996 | 59.42369 | 0.63498 | 13.58536 |
April | 330.00000 | 23.95719 | 63.97445 | 0.67489 | 14.72816 |
May | 344.00000 | 23.95097 | 67.48131 | -0.1425 | 5.71701 |
June | 336.00000 | 23.94492 | 67.48681 | -0.1337 | 5.65476 |
July | 338.00000 | 23.96206 | 63.93658 | -0.1778 | 5.93983 |
August | 348.00000 | 23.93184 | 69.52304 | -0.1618 | 5.74095 |
September | 330.00000 | 23.94805 | 68.25848 | -0.1574 | 5.75707 |
October | 340.00000 | 23.94406 | 68.24221 | 0.67951 | 14.82556 |
November | 330.00000 | 23.93411 | 64.73655 | 0.65902 | 14.21582 |
December | 338.00000 | 23.94774 | 60.38218 | 0.63336 | 13.54715 |
Annual Sum or Average | 4030.00000 | 23.94623 | 64.20374 | 0.31025 | 10.50450 |
Minimum of Months | 308.00000 | 23.93184 | 58.04711 | -0.1778 | 5.65476 |
Maximum of Months | 348.00000 | 23.96206 | 69.52304 | 0.67951 | 14.82556 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.94581 | 58.22190 | 0.60412 | 12.75899 |
February | 308.00000 | 23.94784 | 58.68853 | 0.61211 | 12.98979 |
March | 348.00000 | 23.93935 | 59.59500 | 0.61539 | 13.06484 |
April | 330.00000 | 23.95613 | 64.22848 | 0.65550 | 14.18126 |
May | 344.00000 | 23.95004 | 67.80147 | -0.1698 | 5.88774 |
June | 336.00000 | 23.94401 | 67.83927 | -0.1621 | 5.82276 |
July | 338.00000 | 23.96076 | 64.23680 | -0.2045 | 6.14521 |
August | 348.00000 | 23.93120 | 69.91537 | -0.1867 | 5.91450 |
September | 330.00000 | 23.94710 | 68.63476 | -0.1830 | 5.93298 |
October | 340.00000 | 23.94329 | 68.61215 | 0.66288 | 14.35142 |
November | 330.00000 | 23.93355 | 65.05549 | 0.64175 | 13.74035 |
December | 338.00000 | 23.94699 | 60.62159 | 0.61537 | 13.07223 |
Annual Sum or Average | 4030.00000 | 23.94544 | 64.49188 | 0.28839 | 10.29095 |
Minimum of Months | 308.00000 | 23.93120 | 58.22190 | -0.2045 | 5.82276 |
Maximum of Months | 348.00000 | 23.96076 | 69.91537 | 0.66288 | 14.35142 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.94552 | 58.31159 | 0.60282 | 12.72483 |
February | 308.00000 | 23.94759 | 58.77207 | 0.61085 | 12.95624 |
March | 348.00000 | 23.93914 | 59.67804 | 0.61419 | 13.03265 |
April | 330.00000 | 23.95587 | 64.31675 | 0.65437 | 14.14879 |
May | 344.00000 | 23.94982 | 67.89629 | -0.1716 | 5.89802 |
June | 336.00000 | 23.94379 | 67.93500 | -0.1639 | 5.83282 |
July | 338.00000 | 23.96046 | 64.33109 | -0.2063 | 6.15810 |
August | 348.00000 | 23.93100 | 70.02282 | -0.1884 | 5.92607 |
September | 330.00000 | 23.94684 | 68.73740 | -0.1847 | 5.94401 |
October | 340.00000 | 23.94302 | 68.72599 | 0.66183 | 14.32065 |
November | 330.00000 | 23.93331 | 65.16390 | 0.64061 | 13.70838 |
December | 338.00000 | 23.94667 | 60.72055 | 0.61409 | 13.03801 |
Annual Sum or Average | 4030.00000 | 23.94519 | 64.58868 | 0.28696 | 10.27668 |
Minimum of Months | 308.00000 | 23.93100 | 58.31159 | -0.2063 | 5.83282 |
Maximum of Months | 348.00000 | 23.96046 | 70.02282 | 0.66183 | 14.32065 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.94540 | 58.32765 | 0.60492 | 12.77837 |
February | 308.00000 | 23.94757 | 58.74915 | 0.61343 | 13.02347 |
March | 348.00000 | 23.93918 | 59.64074 | 0.61699 | 13.10673 |
April | 330.00000 | 23.95594 | 64.23951 | 0.65751 | 14.23695 |
May | 344.00000 | 23.94994 | 67.82781 | -0.1672 | 5.87054 |
June | 336.00000 | 23.94390 | 67.84236 | -0.1592 | 5.80463 |
July | 338.00000 | 23.96058 | 64.27507 | -0.2022 | 6.12550 |
August | 348.00000 | 23.93097 | 69.98024 | -0.1845 | 5.89806 |
September | 330.00000 | 23.94688 | 68.67805 | -0.1805 | 5.91487 |
October | 340.00000 | 23.94300 | 68.74235 | 0.66412 | 14.38570 |
November | 330.00000 | 23.93320 | 65.17853 | 0.64279 | 13.76777 |
December | 338.00000 | 23.94650 | 60.75088 | 0.61605 | 13.08906 |
Annual Sum or Average | 4030.00000 | 23.94519 | 64.55705 | 0.29016 | 10.30235 |
Minimum of Months | 308.00000 | 23.93097 | 58.32765 | -0.2022 | 5.80463 |
Maximum of Months | 348.00000 | 23.96058 | 69.98024 | 0.66412 | 14.38570 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.95037 | 56.88063 | 0.63337 | 13.54213 |
February | 308.00000 | 23.95321 | 57.03940 | 0.64602 | 13.91385 |
March | 348.00000 | 23.94422 | 57.91819 | 0.65216 | 14.07932 |
April | 330.00000 | 23.96233 | 62.08848 | 0.69382 | 15.30395 |
May | 344.00000 | 23.95563 | 65.81703 | -0.1151 | 5.64046 |
June | 336.00000 | 23.94917 | 65.55203 | -0.1031 | 5.56791 |
July | 338.00000 | 23.96830 | 62.26754 | -0.1522 | 5.82971 |
August | 348.00000 | 23.93503 | 67.90720 | -0.1382 | 5.65176 |
September | 330.00000 | 23.95337 | 66.46236 | -0.1313 | 5.66590 |
October | 340.00000 | 23.94836 | 67.05158 | 0.68861 | 15.11494 |
November | 330.00000 | 23.93722 | 63.46770 | 0.66767 | 14.47503 |
December | 338.00000 | 23.95175 | 59.25842 | 0.64236 | 13.80785 |
Annual Sum or Average | 4030.00000 | 23.95068 | 62.68009 | 0.32871 | 10.68008 |
Minimum of Months | 308.00000 | 23.93503 | 56.88063 | -0.1522 | 5.56791 |
Maximum of Months | 348.00000 | 23.96830 | 67.90720 | 0.69382 | 15.30395 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.418293E+11 | 0.102824E+11 | 499.04 | 0.259145E+11 | 0.159148E+11 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 57997.92 | 10-JAN-08:62 | 37132.67 | 24-JAN-08:62 | 27488.95 | 10-JAN-08:03 | 13144.96 | 11-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.406299E+11 | 0.100792E+11 | 451.88 | 0.252254E+11 | 0.154045E+11 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 57791.06 | 16-FEB-08:62 | 38624.67 | 21-FEB-08:61 | 26584.87 | 16-FEB-08:03 | 12825.48 | 18-FEB-08:62 | 0.00 | 01-FEB-00:03 |
March | 0.475407E+11 | 0.118192E+11 | 503.52 | 0.291631E+11 | 0.183777E+11 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 58684.89 | 28-MAR-07:01 | 36787.10 | 04-MAR-08:62 | 29228.76 | 28-MAR-07:04 | 12898.67 | 30-MAR-07:01 | 0.00 | 01-MAR-00:03 |
April | 0.528351E+11 | 0.128474E+11 | 487.71 | 0.295988E+11 | 0.232363E+11 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 58843.78 | 12-APR-07:01 | 32972.21 | 27-APR-07:01 | 29702.30 | 01-APR-07:04 | 13008.51 | 11-APR-07:04 | 0.00 | 01-APR-00:03 |
May | 0.591758E+11 | 0.141338E+11 | 503.13 | 0.306446E+11 | 0.285312E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 60020.83 | 19-MAY-07:01 | 30677.30 | 11-MAY-07:02 | 35659.53 | 22-MAY-07:04 | 13594.31 | 28-MAY-07:04 | 0.00 | 01-MAY-00:10 |
June | 0.588642E+11 | 0.140350E+11 | 488.10 | 0.303676E+11 | 0.284966E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 59998.31 | 10-JUN-07:01 | 31624.99 | 27-JUN-07:02 | 34311.54 | 10-JUN-07:04 | 13345.50 | 16-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.480781E+11 | 0.115078E+11 | 502.30 | 0.268047E+11 | 0.212734E+11 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 58451.02 | 01-JUL-07:02 | 35368.21 | 09-JUL-07:01 | 29072.08 | 01-JUL-07:03 | 12765.41 | 15-JUL-07:01 | 0.00 | 01-JUL-00:05 |
August | 0.541397E+11 | 0.126635E+11 | 502.97 | 0.268951E+11 | 0.272446E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 59926.31 | 11-AUG-07:01 | 32094.69 | 24-AUG-07:02 | 33412.20 | 11-AUG-07:04 | 13043.39 | 09-AUG-07:04 | 0.00 | 01-AUG-00:10 |
September | 0.516752E+11 | 0.121504E+11 | 488.52 | 0.264570E+11 | 0.252182E+11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 59104.58 | 01-SEP-07:02 | 32666.74 | 10-SEP-07:01 | 30659.71 | 01-SEP-07:03 | 12958.66 | 01-SEP-07:03 | 0.00 | 01-SEP-00:10 |
October | 0.492827E+11 | 0.115521E+11 | 501.96 | 0.251549E+11 | 0.241278E+11 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 58704.65 | 14-OCT-07:02 | 32478.31 | 08-OCT-07:02 | 30378.62 | 14-OCT-07:03 | 12908.67 | 05-OCT-07:03 | 0.00 | 01-OCT-00:03 |
November | 0.451494E+11 | 0.107209E+11 | 484.87 | 0.244984E+11 | 0.206510E+11 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 58365.82 | 12-NOV-08:62 | 35592.40 | 25-NOV-08:62 | 28562.80 | 12-NOV-08:03 | 12898.57 | 14-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.427065E+11 | 0.103325E+11 | 502.79 | 0.250942E+11 | 0.176123E+11 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-01:05 | 57789.75 | 11-DEC-08:62 | 36303.68 | 27-DEC-08:62 | 26685.92 | 11-DEC-08:03 | 12847.26 | 09-DEC-08:62 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.591907E+12 | 0.142124E+12 | 5916.79 | 0.325818E+12 | 0.266088E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.406299E+11 | 0.100792E+11 | 451.88 | 0.244984E+11 | 0.154045E+11 | 0.00 | 1.00 | 0.00 | 57789.75 | 30677.30 | 26584.87 | 12765.41 | 0.00 | |||||||
Maximum of Months | 0.591758E+11 | 0.141338E+11 | 503.52 | 0.306446E+11 | 0.285312E+11 | 0.00 | 1.00 | 0.00 | 60020.83 | 38624.67 | 35659.53 | 13594.31 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.206840E+11 | 0.508436E+10 | 499.38 | 0.132037E+11 | 0.748035E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 29476.53 | 10-JAN-08:62 | 21118.54 | 24-JAN-08:62 | 11358.76 | 10-JAN-08:03 | 6726.13 | 11-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.199529E+11 | 0.495081E+10 | 452.54 | 0.127115E+11 | 0.724149E+10 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 29403.39 | 16-FEB-08:62 | 21988.32 | 21-FEB-08:61 | 11070.97 | 16-FEB-08:03 | 6545.32 | 18-FEB-08:62 | 0.00 | 01-FEB-00:03 |
March | 0.231870E+11 | 0.577350E+10 | 502.94 | 0.145947E+11 | 0.859228E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 29798.95 | 28-MAR-07:01 | 21116.67 | 03-MAR-08:62 | 12190.32 | 28-MAR-07:03 | 6610.62 | 30-MAR-07:01 | 0.00 | 01-MAR-00:03 |
April | 0.255848E+11 | 0.623908E+10 | 488.05 | 0.147276E+11 | 0.108572E+11 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 29909.15 | 12-APR-07:01 | 19187.84 | 27-APR-07:01 | 12480.06 | 12-APR-07:03 | 6676.89 | 11-APR-07:01 | 0.00 | 01-APR-00:03 |
May | 0.287956E+11 | 0.688896E+10 | 502.95 | 0.153592E+11 | 0.134364E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 30665.00 | 22-MAY-07:01 | 18530.19 | 11-MAY-07:02 | 15535.06 | 22-MAY-07:12 | 7006.90 | 28-MAY-07:04 | 0.00 | 01-MAY-00:10 |
June | 0.286676E+11 | 0.683875E+10 | 488.06 | 0.152006E+11 | 0.134671E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 30638.85 | 14-JUN-07:01 | 19312.60 | 25-JUN-07:01 | 15152.80 | 10-JUN-07:13 | 6791.95 | 16-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.234737E+11 | 0.562724E+10 | 502.25 | 0.134755E+11 | 0.999820E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 29555.75 | 01-JUL-07:02 | 20512.89 | 09-JUL-07:01 | 11662.94 | 01-JUL-07:03 | 6528.01 | 15-JUL-07:01 | 0.00 | 01-JUL-00:05 |
August | 0.264937E+11 | 0.619795E+10 | 502.23 | 0.135738E+11 | 0.129199E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 30352.74 | 11-AUG-07:01 | 19137.65 | 24-AUG-07:02 | 14117.69 | 11-AUG-07:03 | 6710.65 | 09-AUG-07:01 | 0.00 | 01-AUG-00:10 |
September | 0.252000E+11 | 0.593286E+10 | 487.99 | 0.133117E+11 | 0.118883E+11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 29940.81 | 01-SEP-07:02 | 19584.70 | 10-SEP-07:01 | 12866.99 | 01-SEP-07:03 | 6663.40 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 0.242568E+11 | 0.568802E+10 | 501.44 | 0.128195E+11 | 0.114372E+11 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 29742.63 | 05-OCT-07:02 | 19601.01 | 08-OCT-07:02 | 12132.90 | 05-OCT-07:03 | 6626.24 | 05-OCT-07:02 | 0.00 | 01-OCT-00:03 |
November | 0.222379E+11 | 0.528209E+10 | 484.55 | 0.124813E+11 | 0.975654E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 29501.01 | 12-NOV-08:62 | 20719.03 | 25-NOV-08:62 | 11379.47 | 12-NOV-08:03 | 6608.51 | 14-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.211144E+11 | 0.511175E+10 | 502.91 | 0.128532E+11 | 0.826120E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-01:05 | 29276.07 | 10-DEC-08:61 | 21064.39 | 27-DEC-08:62 | 10650.13 | 11-DEC-08:03 | 6566.96 | 09-DEC-08:62 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.289648E+12 | 0.696154E+11 | 5915.28 | 0.164312E+12 | 0.125336E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.199529E+11 | 0.495081E+10 | 452.54 | 0.124813E+11 | 0.724149E+10 | 0.00 | 1.00 | 0.00 | 29276.07 | 18530.19 | 10650.13 | 6528.01 | 0.00 | |||||||
Maximum of Months | 0.287956E+11 | 0.688896E+10 | 502.95 | 0.153592E+11 | 0.134671E+11 | 0.00 | 1.00 | 0.00 | 30665.00 | 21988.32 | 15535.06 | 7006.90 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.170212E+11 | 0.411092E+10 | 366.12 | 0.106213E+11 | 0.639988E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 31319.64 | 02-JAN-07:02 | 17972.71 | 24-JAN-07:02 | 17761.77 | 02-JAN-07:02 | 6496.76 | 11-JAN-07:02 | 0.00 | 01-JAN-00:05 |
February | 0.165565E+11 | 0.403887E+10 | 331.83 | 0.103133E+11 | 0.624324E+10 | 0.00 | 1.00 | 01-FEB-07:02 | 0.00 | 01-FEB-00:03 | 31059.80 | 06-FEB-07:02 | 19188.10 | 25-FEB-07:02 | 16683.13 | 06-FEB-07:02 | 6549.26 | 18-FEB-07:02 | 0.00 | 01-FEB-00:03 |
March | 0.195586E+11 | 0.479732E+10 | 377.44 | 0.120405E+11 | 0.751816E+10 | 0.00 | 1.00 | 01-MAR-07:01 | 0.00 | 01-MAR-00:03 | 31491.85 | 27-MAR-06:01 | 18322.22 | 04-MAR-07:02 | 17596.02 | 27-MAR-06:01 | 6605.64 | 26-MAR-07:04 | 0.00 | 01-MAR-00:03 |
April | 0.213451E+11 | 0.511756E+10 | 359.24 | 0.119567E+11 | 0.938840E+10 | 0.00 | 1.00 | 01-APR-06:01 | 0.00 | 01-APR-00:03 | 31556.05 | 10-APR-06:02 | 16438.93 | 27-APR-06:01 | 19403.05 | 03-APR-06:03 | 6672.29 | 30-APR-07:13 | 0.00 | 01-APR-00:03 |
May | 0.243975E+11 | 0.574202E+10 | 374.43 | 0.125947E+11 | 0.118027E+11 | 0.00 | 1.00 | 01-MAY-06:01 | 0.00 | 01-MAY-00:10 | 31629.50 | 17-MAY-06:01 | 15282.16 | 06-MAY-13:00 | 21929.87 | 22-MAY-06:02 | 6971.17 | 28-MAY-07:01 | 0.00 | 01-MAY-00:10 |
June | 0.244894E+11 | 0.575590E+10 | 365.13 | 0.125654E+11 | 0.119240E+11 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 31626.01 | 26-JUN-06:01 | 14755.52 | 30-JUN-06:01 | 20463.34 | 05-JUN-06:02 | 6710.96 | 15-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.193758E+11 | 0.454141E+10 | 367.37 | 0.106780E+11 | 0.869778E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 31580.79 | 02-JUL-07:01 | 16427.84 | 06-JUL-06:01 | 17965.76 | 05-JUL-06:01 | 6560.00 | 09-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.225983E+11 | 0.518580E+10 | 377.71 | 0.111100E+11 | 0.114883E+11 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 31627.78 | 21-AUG-06:02 | 15116.19 | 24-AUG-06:02 | 20642.51 | 14-AUG-06:02 | 6630.90 | 13-AUG-07:13 | 0.00 | 01-AUG-00:10 |
September | 0.211080E+11 | 0.486812E+10 | 358.54 | 0.106934E+11 | 0.104146E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 31628.30 | 18-SEP-06:02 | 14961.43 | 13-SEP-06:02 | 20164.97 | 25-SEP-06:01 | 6621.35 | 03-SEP-07:13 | 0.00 | 01-SEP-00:10 |
October | 0.202841E+11 | 0.465469E+10 | 369.46 | 0.102686E+11 | 0.100155E+11 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 31629.08 | 02-OCT-06:02 | 14796.12 | 11-OCT-06:02 | 19326.98 | 16-OCT-06:04 | 6570.67 | 05-OCT-06:04 | 0.00 | 01-OCT-00:03 |
November | 0.185167E+11 | 0.431376E+10 | 358.13 | 0.100740E+11 | 0.844272E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 31583.93 | 13-NOV-07:02 | 17228.50 | 25-NOV-07:02 | 19307.48 | 13-NOV-07:03 | 6612.63 | 23-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.172753E+11 | 0.411085E+10 | 364.16 | 0.102771E+11 | 0.699814E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 31623.41 | 11-DEC-07:02 | 18531.49 | 21-DEC-07:03 | 19646.47 | 11-DEC-07:02 | 6539.11 | 10-DEC-08:04 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.242526E+12 | 0.572372E+11 | 4369.56 | 0.133193E+12 | 0.109333E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.165565E+11 | 0.403887E+10 | 331.83 | 0.100740E+11 | 0.624324E+10 | 0.00 | 1.00 | 0.00 | 31059.80 | 14755.52 | 16683.13 | 6496.76 | 0.00 | |||||||
Maximum of Months | 0.244894E+11 | 0.575590E+10 | 377.71 | 0.125947E+11 | 0.119240E+11 | 0.00 | 1.00 | 0.00 | 31629.50 | 19188.10 | 21929.87 | 6971.17 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.170612E+11 | 0.412100E+10 | 366.54 | 0.106512E+11 | 0.641000E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 31419.39 | 02-JAN-07:02 | 18049.79 | 24-JAN-07:02 | 17789.77 | 02-JAN-07:02 | 6516.53 | 11-JAN-07:02 | 0.00 | 01-JAN-00:05 |
February | 0.165982E+11 | 0.404920E+10 | 332.02 | 0.103448E+11 | 0.625333E+10 | 0.00 | 1.00 | 01-FEB-07:02 | 0.00 | 01-FEB-00:03 | 31161.66 | 06-FEB-07:02 | 19271.00 | 25-FEB-07:02 | 16696.37 | 06-FEB-07:02 | 6569.24 | 18-FEB-07:02 | 0.00 | 01-FEB-00:03 |
March | 0.196072E+11 | 0.480957E+10 | 377.49 | 0.120770E+11 | 0.753020E+10 | 0.00 | 1.00 | 01-MAR-07:01 | 0.00 | 01-MAR-00:03 | 31600.06 | 27-MAR-06:01 | 18388.28 | 04-MAR-07:02 | 17585.78 | 27-MAR-06:01 | 6625.66 | 26-MAR-07:04 | 0.00 | 01-MAR-00:03 |
April | 0.214073E+11 | 0.513284E+10 | 359.33 | 0.120019E+11 | 0.940538E+10 | 0.00 | 1.00 | 01-APR-06:01 | 0.00 | 01-APR-00:03 | 31657.00 | 10-APR-06:02 | 16519.99 | 27-APR-06:01 | 19379.81 | 03-APR-06:03 | 6692.60 | 30-APR-07:13 | 0.00 | 01-APR-00:03 |
May | 0.244810E+11 | 0.576283E+10 | 374.51 | 0.126542E+11 | 0.118268E+11 | 0.00 | 1.00 | 01-MAY-06:01 | 0.00 | 01-MAY-00:10 | 31725.64 | 17-MAY-06:01 | 15308.08 | 06-MAY-13:00 | 21938.63 | 22-MAY-06:02 | 6992.36 | 28-MAY-07:01 | 0.00 | 01-MAY-00:10 |
June | 0.245664E+11 | 0.577541E+10 | 365.26 | 0.126209E+11 | 0.119456E+11 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 31722.15 | 26-JUN-06:01 | 14826.98 | 30-JUN-06:01 | 20464.75 | 05-JUN-06:02 | 6722.93 | 15-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.194442E+11 | 0.455737E+10 | 367.51 | 0.107265E+11 | 0.871775E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 31676.78 | 02-JUL-07:01 | 16521.56 | 06-JUL-06:01 | 17966.27 | 05-JUL-06:01 | 6579.92 | 09-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.226415E+11 | 0.519700E+10 | 377.69 | 0.111411E+11 | 0.115003E+11 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 31723.92 | 21-AUG-06:02 | 15175.00 | 24-AUG-06:02 | 20632.63 | 14-AUG-06:02 | 6651.05 | 13-AUG-07:13 | 0.00 | 01-AUG-00:10 |
September | 0.211581E+11 | 0.488053E+10 | 358.64 | 0.107293E+11 | 0.104288E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 31724.44 | 18-SEP-06:02 | 15032.51 | 13-SEP-06:02 | 20163.89 | 25-SEP-06:01 | 6641.60 | 03-SEP-07:13 | 0.00 | 01-SEP-00:10 |
October | 0.203286E+11 | 0.466552E+10 | 369.39 | 0.102999E+11 | 0.100287E+11 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 31725.22 | 02-OCT-06:02 | 14882.84 | 11-OCT-06:02 | 19340.97 | 16-OCT-06:04 | 6590.62 | 05-OCT-06:04 | 0.00 | 01-OCT-00:03 |
November | 0.185429E+11 | 0.432075E+10 | 358.11 | 0.100939E+11 | 0.844903E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 31679.94 | 13-NOV-07:02 | 17301.49 | 25-NOV-07:02 | 19335.48 | 13-NOV-07:03 | 6632.71 | 23-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.172996E+11 | 0.411754E+10 | 364.25 | 0.102956E+11 | 0.700408E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 31719.54 | 11-DEC-07:02 | 18589.70 | 21-DEC-07:03 | 19659.65 | 11-DEC-07:02 | 6558.96 | 10-DEC-08:04 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.243136E+12 | 0.573896E+11 | 4370.74 | 0.133636E+12 | 0.109500E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.165982E+11 | 0.404920E+10 | 332.02 | 0.100939E+11 | 0.625333E+10 | 0.00 | 1.00 | 0.00 | 31161.66 | 14826.98 | 16696.37 | 6516.53 | 0.00 | |||||||
Maximum of Months | 0.245664E+11 | 0.577541E+10 | 377.69 | 0.126542E+11 | 0.119456E+11 | 0.00 | 1.00 | 0.00 | 31725.64 | 19271.00 | 21938.63 | 6992.36 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.168268E+11 | 0.406511E+10 | 366.21 | 0.104763E+11 | 0.635047E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 31135.68 | 02-JAN-07:02 | 17791.89 | 24-JAN-07:02 | 17710.43 | 02-JAN-07:02 | 6459.63 | 11-JAN-07:02 | 0.00 | 01-JAN-00:05 |
February | 0.163862E+11 | 0.399775E+10 | 331.77 | 0.101857E+11 | 0.620048E+10 | 0.00 | 1.00 | 01-FEB-07:02 | 0.00 | 01-FEB-00:03 | 30879.63 | 06-FEB-07:02 | 18990.11 | 25-FEB-07:02 | 16619.86 | 06-FEB-07:02 | 6511.78 | 18-FEB-07:02 | 0.00 | 01-FEB-00:03 |
March | 0.193637E+11 | 0.474995E+10 | 377.51 | 0.118954E+11 | 0.746831E+10 | 0.00 | 1.00 | 01-MAR-07:01 | 0.00 | 01-MAR-00:03 | 31315.76 | 27-MAR-06:01 | 18114.30 | 04-MAR-07:02 | 17496.97 | 27-MAR-06:01 | 6567.91 | 26-MAR-07:04 | 0.00 | 01-MAR-00:03 |
April | 0.211676E+11 | 0.507379E+10 | 359.23 | 0.118292E+11 | 0.933843E+10 | 0.00 | 1.00 | 01-APR-06:01 | 0.00 | 01-APR-00:03 | 31372.06 | 10-APR-06:02 | 16247.08 | 27-APR-06:01 | 19278.58 | 03-APR-06:03 | 6633.76 | 30-APR-07:13 | 0.00 | 01-APR-00:03 |
May | 0.242397E+11 | 0.570260E+10 | 374.35 | 0.124851E+11 | 0.117545E+11 | 0.00 | 1.00 | 01-MAY-06:01 | 0.00 | 01-MAY-00:10 | 31448.84 | 17-MAY-06:01 | 15171.33 | 06-MAY-13:00 | 21828.04 | 22-MAY-06:02 | 6931.35 | 28-MAY-07:01 | 0.00 | 01-MAY-00:10 |
June | 0.243282E+11 | 0.571563E+10 | 365.11 | 0.124525E+11 | 0.118756E+11 | 0.00 | 1.00 | 01-JUN-06:01 | 0.00 | 01-JUN-00:10 | 31445.37 | 26-JUN-06:01 | 14553.42 | 30-JUN-06:01 | 20371.11 | 05-JUN-06:02 | 6671.57 | 15-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.192052E+11 | 0.450084E+10 | 367.41 | 0.105567E+11 | 0.864855E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 31399.83 | 02-JUL-07:01 | 16265.73 | 06-JUL-06:01 | 17901.48 | 02-JUL-07:01 | 6522.52 | 09-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.223685E+11 | 0.513234E+10 | 378.01 | 0.109560E+11 | 0.114125E+11 | 0.00 | 1.00 | 01-AUG-06:01 | 0.00 | 01-AUG-00:10 | 31447.13 | 21-AUG-06:02 | 14904.49 | 24-AUG-06:02 | 20525.03 | 14-AUG-06:02 | 6593.02 | 13-AUG-07:13 | 0.00 | 01-AUG-00:10 |
September | 0.209073E+11 | 0.482106E+10 | 358.66 | 0.105566E+11 | 0.103508E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 31447.64 | 18-SEP-06:02 | 14779.15 | 13-SEP-06:02 | 20070.34 | 25-SEP-06:01 | 6582.81 | 03-SEP-07:13 | 0.00 | 01-SEP-00:10 |
October | 0.200678E+11 | 0.460490E+10 | 369.64 | 0.101219E+11 | 0.994585E+10 | 0.00 | 1.00 | 01-OCT-07:01 | 0.00 | 01-OCT-00:03 | 31448.42 | 02-OCT-06:02 | 14640.91 | 11-OCT-06:02 | 19243.88 | 16-OCT-06:04 | 6533.13 | 05-OCT-06:04 | 0.00 | 01-OCT-00:03 |
November | 0.182971E+11 | 0.426338E+10 | 358.05 | 0.992066E+10 | 0.837640E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 31403.53 | 13-NOV-07:02 | 17045.81 | 25-NOV-07:02 | 19248.69 | 13-NOV-07:02 | 6574.86 | 23-NOV-08:61 | 0.00 | 01-NOV-00:10 |
December | 0.170547E+11 | 0.406016E+10 | 364.45 | 0.101170E+11 | 0.693763E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 31442.79 | 11-DEC-07:02 | 17593.28 | 27-DEC-07:02 | 19562.64 | 11-DEC-07:02 | 6501.86 | 10-DEC-08:04 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.240213E+12 | 0.566875E+11 | 4370.39 | 0.131553E+12 | 0.108660E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.163862E+11 | 0.399775E+10 | 331.77 | 0.992066E+10 | 0.620048E+10 | 0.00 | 1.00 | 0.00 | 30879.63 | 14553.42 | 16619.86 | 6459.63 | 0.00 | |||||||
Maximum of Months | 0.243282E+11 | 0.571563E+10 | 378.01 | 0.124851E+11 | 0.118756E+11 | 0.00 | 1.00 | 0.00 | 31448.84 | 18990.11 | 21828.04 | 6931.35 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.297943E+11 | 0.729034E+10 | 356.93 | 0.182770E+11 | 0.115173E+11 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 54316.71 | 02-JAN-08:62 | 32163.97 | 24-JAN-08:62 | 30783.10 | 02-JAN-08:62 | 11951.88 | 11-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.290848E+11 | 0.718562E+10 | 323.24 | 0.178157E+11 | 0.112691E+11 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 53856.14 | 06-FEB-08:62 | 35069.36 | 25-FEB-08:62 | 28619.61 | 06-FEB-08:62 | 11831.04 | 20-FEB-09:13 | 0.00 | 01-FEB-00:03 |
March | 0.344022E+11 | 0.854399E+10 | 369.77 | 0.208533E+11 | 0.135489E+11 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 54627.43 | 27-MAR-07:01 | 32936.52 | 04-MAR-08:62 | 30431.80 | 27-MAR-07:01 | 11995.84 | 26-MAR-08:13 | 0.00 | 01-MAR-00:03 |
April | 0.377056E+11 | 0.914156E+10 | 349.05 | 0.207286E+11 | 0.169771E+11 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 54694.54 | 10-APR-07:02 | 29900.75 | 27-APR-07:01 | 33494.87 | 03-APR-07:03 | 11921.96 | 30-APR-08:15 | 0.00 | 01-APR-00:03 |
May | 0.433677E+11 | 0.103224E+11 | 365.59 | 0.219174E+11 | 0.214503E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 54664.04 | 15-MAY-07:01 | 27616.74 | 31-MAY-07:01 | 37616.80 | 22-MAY-07:01 | 12229.24 | 07-MAY-08:23 | 0.00 | 01-MAY-00:10 |
June | 0.437039E+11 | 0.103882E+11 | 357.41 | 0.219588E+11 | 0.217451E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 54722.26 | 26-JUN-07:02 | 28149.24 | 20-JUN-07:01 | 35316.65 | 05-JUN-07:01 | 12434.73 | 13-JUN-14:20 | 0.00 | 01-JUN-00:10 |
July | 0.339109E+11 | 0.803799E+10 | 355.67 | 0.182790E+11 | 0.156318E+11 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 54679.64 | 02-JUL-08:61 | 30699.50 | 06-JUL-07:01 | 31313.28 | 02-JUL-08:03 | 11724.15 | 30-JUL-08:04 | 0.00 | 01-JUL-00:05 |
August | 0.398548E+11 | 0.924403E+10 | 370.13 | 0.190314E+11 | 0.208235E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 54784.17 | 21-AUG-07:02 | 28057.05 | 16-AUG-07:02 | 35271.88 | 14-AUG-07:01 | 11972.99 | 13-AUG-08:25 | 0.00 | 01-AUG-00:10 |
September | 0.371016E+11 | 0.865143E+10 | 348.86 | 0.183123E+11 | 0.187893E+11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 54846.26 | 18-SEP-07:02 | 28465.13 | 06-SEP-07:01 | 35013.02 | 25-SEP-07:03 | 11841.35 | 10-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.354528E+11 | 0.822286E+10 | 359.27 | 0.174326E+11 | 0.180202E+11 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 54815.98 | 02-OCT-07:02 | 28269.83 | 11-OCT-07:02 | 33592.21 | 23-OCT-07:02 | 11823.14 | 29-OCT-08:13 | 0.00 | 01-OCT-00:03 |
November | 0.323364E+11 | 0.761834E+10 | 349.04 | 0.171272E+11 | 0.152091E+11 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 54709.10 | 20-NOV-08:61 | 31030.18 | 25-NOV-08:62 | 33378.02 | 12-NOV-09:05 | 11844.49 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.300266E+11 | 0.723355E+10 | 354.19 | 0.175016E+11 | 0.125250E+11 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 54758.63 | 11-DEC-08:62 | 32866.50 | 27-DEC-08:62 | 33719.41 | 11-DEC-08:62 | 11891.53 | 31-DEC-09:13 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.426742E+12 | 0.101880E+12 | 4259.15 | 0.229235E+12 | 0.197507E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.290848E+11 | 0.718562E+10 | 323.24 | 0.171272E+11 | 0.112691E+11 | 0.00 | 1.00 | 0.00 | 53856.14 | 27616.74 | 28619.61 | 11724.15 | 0.00 | |||||||
Maximum of Months | 0.437039E+11 | 0.103882E+11 | 370.13 | 0.219588E+11 | 0.217451E+11 | 0.00 | 1.00 | 0.00 | 54846.26 | 35069.36 | 37616.80 | 12434.73 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.154355E+11 | 0.372115E+10 | 357.26 | 0.947576E+10 | 0.595974E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 28579.45 | 02-JAN-08:62 | 16963.30 | 24-JAN-08:62 | 16259.90 | 02-JAN-08:62 | 6172.24 | 11-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.150804E+11 | 0.367106E+10 | 324.08 | 0.924088E+10 | 0.583951E+10 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 28329.25 | 06-FEB-08:62 | 18430.86 | 25-FEB-08:62 | 15120.19 | 06-FEB-08:62 | 6109.95 | 20-FEB-09:13 | 0.00 | 01-FEB-00:03 |
March | 0.178295E+11 | 0.436446E+10 | 369.63 | 0.108128E+11 | 0.701663E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 28732.23 | 27-MAR-07:01 | 17317.77 | 04-MAR-08:62 | 16055.07 | 27-MAR-07:01 | 6195.19 | 26-MAR-08:13 | 0.00 | 01-MAR-00:03 |
April | 0.195466E+11 | 0.467036E+10 | 349.17 | 0.107527E+11 | 0.879381E+10 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 28750.07 | 10-APR-07:02 | 15748.47 | 27-APR-07:01 | 17679.11 | 03-APR-07:03 | 6157.98 | 30-APR-08:15 | 0.00 | 01-APR-00:03 |
May | 0.224705E+11 | 0.526835E+10 | 365.60 | 0.113679E+11 | 0.111027E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 28734.04 | 15-MAY-07:01 | 14589.48 | 31-MAY-07:01 | 19879.54 | 22-MAY-07:01 | 6317.93 | 07-MAY-08:23 | 0.00 | 01-MAY-00:10 |
June | 0.226287E+11 | 0.529759E+10 | 357.53 | 0.113771E+11 | 0.112516E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 28764.64 | 26-JUN-07:02 | 14846.22 | 20-JUN-07:01 | 18705.57 | 05-JUN-07:01 | 6416.23 | 13-JUN-14:20 | 0.00 | 01-JUN-00:10 |
July | 0.175525E+11 | 0.409986E+10 | 356.29 | 0.947034E+10 | 0.808214E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 28753.35 | 05-JUL-07:01 | 16174.06 | 06-JUL-07:01 | 16532.98 | 02-JUL-08:03 | 6054.75 | 30-JUL-08:04 | 0.00 | 01-JUL-00:05 |
August | 0.206124E+11 | 0.471065E+10 | 370.30 | 0.985355E+10 | 0.107588E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 28797.18 | 21-AUG-07:02 | 14778.73 | 16-AUG-07:02 | 18635.17 | 14-AUG-07:01 | 6183.25 | 13-AUG-08:25 | 0.00 | 01-AUG-00:10 |
September | 0.192070E+11 | 0.441233E+10 | 348.86 | 0.948845E+10 | 0.971853E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 28829.82 | 18-SEP-07:02 | 15008.53 | 06-SEP-07:01 | 18495.00 | 25-SEP-07:02 | 6115.56 | 10-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.183458E+11 | 0.419263E+10 | 359.43 | 0.903073E+10 | 0.931509E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 28829.05 | 23-OCT-07:02 | 14921.81 | 11-OCT-07:02 | 17738.26 | 16-OCT-07:05 | 6105.99 | 29-OCT-08:13 | 0.00 | 01-OCT-00:03 |
November | 0.167297E+11 | 0.388396E+10 | 348.91 | 0.886948E+10 | 0.786019E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 28777.75 | 20-NOV-08:61 | 16340.21 | 25-NOV-08:62 | 17652.40 | 12-NOV-09:03 | 6116.83 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.155426E+11 | 0.368954E+10 | 355.40 | 0.906613E+10 | 0.647644E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 28783.76 | 11-DEC-08:62 | 17311.93 | 27-DEC-08:62 | 17858.66 | 11-DEC-08:62 | 6141.21 | 31-DEC-09:13 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.220981E+12 | 0.519819E+11 | 4262.47 | 0.118806E+12 | 0.102175E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.150804E+11 | 0.367106E+10 | 324.08 | 0.886948E+10 | 0.583951E+10 | 0.00 | 1.00 | 0.00 | 28329.25 | 14589.48 | 15120.19 | 6054.75 | 0.00 | |||||||
Maximum of Months | 0.226287E+11 | 0.529759E+10 | 370.30 | 0.113771E+11 | 0.112516E+11 | 0.00 | 1.00 | 0.00 | 28829.82 | 18430.86 | 19879.54 | 6416.23 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.153576E+11 | 0.370175E+10 | 357.12 | 0.941903E+10 | 0.593862E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 28434.56 | 02-JAN-08:62 | 16844.45 | 24-JAN-08:62 | 16194.57 | 02-JAN-08:62 | 6141.19 | 11-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.150139E+11 | 0.365412E+10 | 324.08 | 0.919199E+10 | 0.582191E+10 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 28185.45 | 06-FEB-08:62 | 18311.74 | 25-FEB-08:62 | 15058.59 | 06-FEB-08:62 | 6079.20 | 20-FEB-09:13 | 0.00 | 01-FEB-00:03 |
March | 0.177546E+11 | 0.434499E+10 | 369.47 | 0.107583E+11 | 0.699635E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 28587.50 | 27-MAR-07:01 | 17205.84 | 04-MAR-08:62 | 15986.30 | 27-MAR-07:01 | 6163.97 | 26-MAR-08:13 | 0.00 | 01-MAR-00:03 |
April | 0.194755E+11 | 0.465183E+10 | 349.14 | 0.107024E+11 | 0.877317E+10 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 28605.39 | 10-APR-07:02 | 15638.96 | 27-APR-07:01 | 17599.26 | 03-APR-07:03 | 6126.70 | 30-APR-08:15 | 0.00 | 01-APR-00:03 |
May | 0.223951E+11 | 0.524877E+10 | 365.57 | 0.113157E+11 | 0.110794E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 28589.44 | 15-MAY-07:01 | 14486.75 | 31-MAY-07:01 | 19791.91 | 22-MAY-07:01 | 6285.97 | 04-MAY-13:00 | 0.00 | 01-MAY-00:10 |
June | 0.225530E+11 | 0.527789E+10 | 357.53 | 0.113243E+11 | 0.112287E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 28619.89 | 26-JUN-07:02 | 14739.63 | 20-JUN-07:01 | 18629.73 | 05-JUN-07:01 | 6400.34 | 13-JUN-14:10 | 0.00 | 01-JUN-00:10 |
July | 0.174792E+11 | 0.408162E+10 | 356.35 | 0.941937E+10 | 0.805987E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 28607.84 | 05-JUL-07:01 | 16061.33 | 06-JUL-07:01 | 16465.65 | 02-JUL-08:03 | 6024.28 | 30-JUL-08:04 | 0.00 | 01-JUL-00:05 |
August | 0.205330E+11 | 0.469083E+10 | 370.30 | 0.980071E+10 | 0.107322E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 28652.26 | 21-AUG-07:02 | 14669.76 | 16-AUG-07:02 | 18552.53 | 14-AUG-07:01 | 6152.14 | 13-AUG-08:25 | 0.00 | 01-AUG-00:10 |
September | 0.191338E+11 | 0.439405E+10 | 348.89 | 0.943901E+10 | 0.969483E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 28684.74 | 18-SEP-07:02 | 14907.39 | 06-SEP-07:01 | 18417.25 | 25-SEP-07:02 | 6084.50 | 10-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.182646E+11 | 0.417263E+10 | 359.20 | 0.897669E+10 | 0.928787E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 28682.55 | 23-OCT-07:02 | 14811.95 | 11-OCT-07:02 | 17664.54 | 16-OCT-07:05 | 6075.05 | 29-OCT-08:13 | 0.00 | 01-OCT-00:03 |
November | 0.166499E+11 | 0.386447E+10 | 348.93 | 0.881472E+10 | 0.783522E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 28632.93 | 20-NOV-08:61 | 16224.13 | 25-NOV-08:62 | 17583.67 | 12-NOV-09:03 | 6086.07 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.154627E+11 | 0.366995E+10 | 355.40 | 0.900919E+10 | 0.645347E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 28638.91 | 11-DEC-08:62 | 17192.34 | 27-DEC-08:62 | 17786.11 | 11-DEC-08:62 | 6110.24 | 31-DEC-09:13 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.220073E+12 | 0.517529E+11 | 4261.99 | 0.118171E+12 | 0.101902E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.150139E+11 | 0.365412E+10 | 324.08 | 0.881472E+10 | 0.582191E+10 | 0.00 | 1.00 | 0.00 | 28185.45 | 14486.75 | 15058.59 | 6024.28 | 0.00 | |||||||
Maximum of Months | 0.225530E+11 | 0.527789E+10 | 370.30 | 0.113243E+11 | 0.112287E+11 | 0.00 | 1.00 | 0.00 | 28684.74 | 18311.74 | 19791.91 | 6400.34 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.153543E+11 | 0.370237E+10 | 357.60 | 0.941722E+10 | 0.593706E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 28507.66 | 02-JAN-08:62 | 16850.34 | 24-JAN-08:62 | 16278.31 | 02-JAN-08:62 | 6158.78 | 11-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.150399E+11 | 0.366145E+10 | 324.29 | 0.921151E+10 | 0.582835E+10 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 28259.99 | 06-FEB-08:62 | 18332.23 | 25-FEB-08:62 | 15123.98 | 06-FEB-08:62 | 6096.64 | 20-FEB-09:13 | 0.00 | 01-FEB-00:03 |
March | 0.177915E+11 | 0.435523E+10 | 369.37 | 0.107867E+11 | 0.700476E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 28665.21 | 27-MAR-07:01 | 17199.18 | 04-MAR-08:62 | 16042.90 | 27-MAR-07:01 | 6181.67 | 26-MAR-08:13 | 0.00 | 01-MAR-00:03 |
April | 0.195329E+11 | 0.466704E+10 | 348.94 | 0.107457E+11 | 0.878725E+10 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 28687.46 | 10-APR-07:02 | 15668.36 | 27-APR-07:01 | 17657.23 | 03-APR-07:03 | 6144.41 | 30-APR-08:15 | 0.00 | 01-APR-00:03 |
May | 0.224517E+11 | 0.526442E+10 | 365.37 | 0.113586E+11 | 0.110931E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 28671.46 | 15-MAY-07:01 | 14528.17 | 31-MAY-07:01 | 19874.58 | 22-MAY-07:01 | 6309.14 | 04-MAY-13:00 | 0.00 | 01-MAY-00:10 |
June | 0.226233E+11 | 0.529661E+10 | 357.38 | 0.113761E+11 | 0.112472E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 28702.00 | 26-JUN-07:02 | 14790.98 | 20-JUN-07:01 | 18713.76 | 05-JUN-07:01 | 6428.97 | 13-JUN-14:10 | 0.00 | 01-JUN-00:10 |
July | 0.175216E+11 | 0.409234E+10 | 355.99 | 0.945018E+10 | 0.807141E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 28685.56 | 05-JUL-07:01 | 16101.88 | 06-JUL-07:01 | 16524.86 | 02-JUL-08:03 | 6041.58 | 30-JUL-08:04 | 0.00 | 01-JUL-00:05 |
August | 0.205649E+11 | 0.469996E+10 | 369.90 | 0.982605E+10 | 0.107389E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 28734.47 | 21-AUG-07:02 | 14710.45 | 16-AUG-07:02 | 18611.24 | 14-AUG-07:01 | 6169.79 | 13-AUG-08:25 | 0.00 | 01-AUG-00:10 |
September | 0.191752E+11 | 0.440514E+10 | 348.56 | 0.947014E+10 | 0.970510E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 28767.04 | 18-SEP-07:02 | 14961.38 | 06-SEP-07:01 | 18487.67 | 25-SEP-07:02 | 6101.98 | 10-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.182577E+11 | 0.417269E+10 | 359.17 | 0.897556E+10 | 0.928210E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 28756.63 | 23-OCT-07:02 | 14824.46 | 11-OCT-07:02 | 17742.11 | 16-OCT-07:05 | 6092.48 | 29-OCT-08:13 | 0.00 | 01-OCT-00:03 |
November | 0.166417E+11 | 0.386403E+10 | 348.98 | 0.881153E+10 | 0.783013E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 28715.08 | 20-NOV-08:61 | 16234.59 | 25-NOV-08:62 | 17665.49 | 12-NOV-09:03 | 6103.52 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.154475E+11 | 0.366820E+10 | 355.88 | 0.899970E+10 | 0.644782E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 28721.08 | 11-DEC-08:62 | 17201.17 | 27-DEC-08:62 | 17869.22 | 11-DEC-08:62 | 6127.73 | 31-DEC-09:13 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.220402E+12 | 0.518495E+11 | 4261.42 | 0.118429E+12 | 0.101973E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.150399E+11 | 0.366145E+10 | 324.29 | 0.881153E+10 | 0.582835E+10 | 0.00 | 1.00 | 0.00 | 28259.99 | 14528.17 | 15123.98 | 6041.58 | 0.00 | |||||||
Maximum of Months | 0.226233E+11 | 0.529661E+10 | 369.90 | 0.113761E+11 | 0.112472E+11 | 0.00 | 1.00 | 0.00 | 28767.04 | 18332.23 | 19874.58 | 6428.97 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.170124E+11 | 0.412726E+10 | 358.38 | 0.106173E+11 | 0.639506E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 32546.77 | 09-JAN-08:62 | 18855.13 | 24-JAN-08:62 | 18796.41 | 09-JAN-08:62 | 6994.97 | 11-JAN-08:03 | 0.00 | 01-JAN-00:05 |
February | 0.167990E+11 | 0.411115E+10 | 325.28 | 0.104962E+11 | 0.630283E+10 | 0.00 | 1.00 | 01-FEB-08:62 | 0.00 | 01-FEB-00:03 | 32206.61 | 20-FEB-09:01 | 20107.55 | 25-FEB-08:62 | 17367.60 | 06-FEB-08:62 | 6924.37 | 20-FEB-09:13 | 0.00 | 01-FEB-00:03 |
March | 0.199856E+11 | 0.491980E+10 | 369.82 | 0.123451E+11 | 0.764045E+10 | 0.00 | 1.00 | 01-MAR-08:62 | 0.00 | 01-MAR-00:03 | 32565.20 | 27-MAR-07:01 | 18768.34 | 04-MAR-08:62 | 19063.10 | 27-MAR-07:03 | 7016.72 | 26-MAR-08:13 | 0.00 | 01-MAR-00:03 |
April | 0.218841E+11 | 0.527059E+10 | 349.33 | 0.123629E+11 | 0.952129E+10 | 0.00 | 1.00 | 01-APR-07:01 | 0.00 | 01-APR-00:03 | 32627.95 | 24-APR-07:01 | 16693.31 | 27-APR-07:01 | 20154.57 | 03-APR-07:01 | 6970.26 | 30-APR-08:13 | 0.00 | 01-APR-00:03 |
May | 0.248501E+11 | 0.588527E+10 | 365.88 | 0.129401E+11 | 0.119099E+11 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 32599.88 | 16-MAY-07:02 | 16230.68 | 06-MAY-13:00 | 22848.98 | 22-MAY-07:01 | 7153.04 | 07-MAY-08:23 | 0.00 | 01-MAY-00:10 |
June | 0.251566E+11 | 0.594898E+10 | 357.71 | 0.130623E+11 | 0.120943E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 32599.88 | 26-JUN-07:02 | 16197.51 | 20-JUN-07:01 | 21574.43 | 05-JUN-07:01 | 7132.26 | 16-JUN-13:00 | 0.00 | 01-JUN-00:10 |
July | 0.195711E+11 | 0.460302E+10 | 356.07 | 0.108557E+11 | 0.871537E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 32636.76 | 05-JUL-07:01 | 18113.77 | 11-JUL-07:02 | 19006.50 | 02-JUL-08:03 | 6860.69 | 09-JUL-08:04 | 0.00 | 01-JUL-00:05 |
August | 0.227920E+11 | 0.526016E+10 | 370.15 | 0.112619E+11 | 0.115301E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 32636.76 | 21-AUG-07:02 | 16372.43 | 16-AUG-07:02 | 21257.72 | 14-AUG-07:01 | 7007.68 | 13-AUG-08:25 | 0.00 | 01-AUG-00:10 |
September | 0.213002E+11 | 0.494012E+10 | 348.89 | 0.108852E+11 | 0.104149E+11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 32673.75 | 18-SEP-07:02 | 16567.02 | 12-SEP-07:02 | 21101.71 | 25-SEP-07:02 | 6932.03 | 10-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.199628E+11 | 0.460738E+10 | 359.62 | 0.101031E+11 | 0.985968E+10 | 0.00 | 1.00 | 01-OCT-08:61 | 0.00 | 01-OCT-00:03 | 32673.32 | 23-OCT-07:02 | 16429.25 | 11-OCT-07:02 | 20328.70 | 16-OCT-07:03 | 6916.33 | 29-OCT-08:13 | 0.00 | 01-OCT-00:03 |
November | 0.183076E+11 | 0.428600E+10 | 349.56 | 0.995012E+10 | 0.835744E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 32647.07 | 05-NOV-08:62 | 18080.37 | 25-NOV-08:62 | 20184.72 | 12-NOV-09:02 | 6933.63 | 23-NOV-09:13 | 0.00 | 01-NOV-00:10 |
December | 0.170424E+11 | 0.407640E+10 | 356.04 | 0.101343E+11 | 0.690806E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 32621.55 | 11-DEC-08:62 | 18954.67 | 27-DEC-08:62 | 20241.98 | 11-DEC-08:62 | 6960.13 | 31-DEC-09:13 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.244664E+12 | 0.580361E+11 | 4266.75 | 0.135014E+12 | 0.109649E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.167990E+11 | 0.407640E+10 | 325.28 | 0.995012E+10 | 0.630283E+10 | 0.00 | 1.00 | 0.00 | 32206.61 | 16197.51 | 17367.60 | 6860.69 | 0.00 | |||||||
Maximum of Months | 0.251566E+11 | 0.594898E+10 | 370.15 | 0.130623E+11 | 0.120943E+11 | 0.00 | 1.00 | 0.00 | 32673.75 | 20107.55 | 22848.98 | 7153.04 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.00 | 9.44 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.55 | 7.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.05 | 4.93 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.94 | 2.26 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.87 | 2.77 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.83 | 3.04 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.78 | 5.38 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.04 | 4.25 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.15 | 4.29 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.15 | 5.37 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.98 | 6.64 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.63 | 5.54 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.04 | 2.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.00 | 9.44 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.55 | 7.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.05 | 4.93 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.94 | 2.26 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.87 | 2.77 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.83 | 3.04 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.78 | 5.38 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.04 | 4.25 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.15 | 4.29 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.15 | 5.37 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.98 | 6.64 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.63 | 5.54 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.04 | 2.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.00 | 9.44 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.55 | 7.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.05 | 4.93 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.94 | 2.26 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.87 | 2.77 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.83 | 3.04 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.78 | 5.38 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.04 | 4.25 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.15 | 4.29 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.15 | 5.37 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.98 | 6.64 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.63 | 5.54 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.04 | 2.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.00 | 9.44 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.55 | 7.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.05 | 4.93 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.94 | 2.26 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.87 | 2.77 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.83 | 3.04 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.78 | 5.38 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.04 | 4.25 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.15 | 4.29 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.15 | 5.37 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.98 | 6.64 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.63 | 5.54 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.04 | 2.26 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.15 | 10.86 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.36 | 26.43 | 36.93 | 119.87 | 11.36 | 0.00 | 0.00 | 744.00 |
February | 53.80 | 17.53 | 36.27 | 102.46 | 8.67 | 0.00 | 0.00 | 672.00 |
March | 36.70 | 4.91 | 31.79 | 75.36 | 5.98 | 0.00 | 0.00 | 744.00 |
April | 27.38 | 0.01 | 27.37 | 67.94 | 2.74 | 0.00 | 0.00 | 720.00 |
May | 27.40 | 0.00 | 27.40 | 70.26 | 3.34 | 0.00 | 0.00 | 744.00 |
June | 27.30 | 0.00 | 27.30 | 69.02 | 3.67 | 0.00 | 0.00 | 720.00 |
July | 28.12 | 0.00 | 28.12 | 61.90 | 6.48 | 0.00 | 0.00 | 744.00 |
August | 27.38 | 0.04 | 27.34 | 59.78 | 5.14 | 0.00 | 0.00 | 744.00 |
September | 30.30 | 0.98 | 29.32 | 65.94 | 5.17 | 0.00 | 0.00 | 720.00 |
October | 39.65 | 6.31 | 33.33 | 75.62 | 6.47 | 0.00 | 0.00 | 744.00 |
November | 51.56 | 15.72 | 35.83 | 98.23 | 8.00 | 0.00 | 0.00 | 720.00 |
December | 63.33 | 26.94 | 36.39 | 120.06 | 13.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.64 | 8.21 | 31.43 | 82.11 | 6.68 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.30 | 0.00 | 27.30 | 59.78 | 2.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.36 | 26.94 | 36.93 | 120.06 | 13.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.36 | 26.43 | 36.93 | 119.87 | 11.36 | 0.00 | 0.00 | 744.00 |
February | 53.80 | 17.53 | 36.27 | 102.46 | 8.67 | 0.00 | 0.00 | 672.00 |
March | 36.70 | 4.91 | 31.79 | 75.36 | 5.98 | 0.00 | 0.00 | 744.00 |
April | 27.38 | 0.01 | 27.37 | 67.94 | 2.74 | 0.00 | 0.00 | 720.00 |
May | 27.40 | 0.00 | 27.40 | 70.26 | 3.34 | 0.00 | 0.00 | 744.00 |
June | 27.30 | 0.00 | 27.30 | 69.02 | 3.67 | 0.00 | 0.00 | 720.00 |
July | 28.12 | 0.00 | 28.12 | 61.90 | 6.48 | 0.00 | 0.00 | 744.00 |
August | 27.38 | 0.04 | 27.34 | 59.78 | 5.14 | 0.00 | 0.00 | 744.00 |
September | 30.30 | 0.98 | 29.32 | 65.94 | 5.17 | 0.00 | 0.00 | 720.00 |
October | 39.65 | 6.31 | 33.33 | 75.62 | 6.47 | 0.00 | 0.00 | 744.00 |
November | 51.56 | 15.72 | 35.83 | 98.23 | 8.00 | 0.00 | 0.00 | 720.00 |
December | 63.33 | 26.94 | 36.39 | 120.06 | 13.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.64 | 8.21 | 31.43 | 82.11 | 6.68 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.30 | 0.00 | 27.30 | 59.78 | 2.74 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.36 | 26.94 | 36.93 | 120.06 | 13.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.40 | 9.37 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 86.15 | 7.06 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.88 | 4.77 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 57.89 | 2.13 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 59.73 | 2.68 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 58.77 | 2.91 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 52.42 | 5.24 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.70 | 4.12 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.81 | 4.16 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.61 | 5.31 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.42 | 6.58 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.48 | 10.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 69.28 | 5.43 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.70 | 2.13 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.48 | 10.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.40 | 9.37 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 86.15 | 7.06 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.88 | 4.77 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 57.89 | 2.13 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 59.73 | 2.68 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 58.77 | 2.91 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 52.42 | 5.24 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.70 | 4.12 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.81 | 4.16 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.61 | 5.31 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.42 | 6.58 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.48 | 10.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 69.28 | 5.43 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.70 | 2.13 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.48 | 10.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.36 | 26.43 | 36.93 | 120.35 | 11.27 | 0.00 | 0.00 | 744.00 |
February | 53.80 | 17.53 | 36.27 | 103.18 | 8.52 | 0.00 | 0.00 | 672.00 |
March | 36.70 | 4.91 | 31.79 | 76.34 | 5.78 | 0.00 | 0.00 | 744.00 |
April | 27.38 | 0.01 | 27.37 | 69.08 | 2.59 | 0.00 | 0.00 | 720.00 |
May | 27.40 | 0.00 | 27.40 | 71.31 | 3.24 | 0.00 | 0.00 | 744.00 |
June | 27.30 | 0.00 | 27.30 | 70.14 | 3.52 | 0.00 | 0.00 | 720.00 |
July | 28.12 | 0.00 | 28.12 | 62.67 | 6.31 | 0.00 | 0.00 | 744.00 |
August | 27.38 | 0.04 | 27.34 | 60.58 | 4.98 | 0.00 | 0.00 | 744.00 |
September | 30.30 | 0.98 | 29.32 | 66.74 | 5.01 | 0.00 | 0.00 | 720.00 |
October | 39.65 | 6.31 | 33.33 | 76.17 | 6.39 | 0.00 | 0.00 | 744.00 |
November | 51.56 | 15.72 | 35.83 | 98.77 | 7.92 | 0.00 | 0.00 | 720.00 |
December | 63.33 | 26.94 | 36.39 | 120.47 | 12.99 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.64 | 8.21 | 31.43 | 82.89 | 6.55 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.30 | 0.00 | 27.30 | 60.58 | 2.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.36 | 26.94 | 36.93 | 120.47 | 12.99 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.11 | 11.56 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.72 | 9.24 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.18 | 6.69 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.89 | 3.15 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.73 | 3.75 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.94 | 4.10 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.20 | 6.98 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.98 | 5.84 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.74 | 5.78 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.01 | 7.22 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.05 | 8.47 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.34 | 12.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.33 | 7.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.98 | 3.15 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.34 | 12.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.11 | 11.56 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.72 | 9.24 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.18 | 6.69 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.89 | 3.15 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.73 | 3.75 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.94 | 4.10 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.20 | 6.98 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.98 | 5.84 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.74 | 5.78 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.01 | 7.22 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.05 | 8.47 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.34 | 12.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.33 | 7.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.98 | 3.15 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.34 | 12.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.36 | 13.78 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 102.13 | 11.04 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 75.15 | 8.02 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 66.40 | 3.79 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 68.59 | 4.49 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 67.65 | 4.90 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 60.93 | 8.32 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.43 | 6.98 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.13 | 6.90 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 75.06 | 8.60 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 97.81 | 10.10 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.65 | 15.44 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.35 | 8.53 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.43 | 3.79 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.65 | 15.44 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.08 | 11.70 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.68 | 9.39 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.15 | 6.86 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.80 | 3.32 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.59 | 3.91 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.84 | 4.29 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.14 | 7.16 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.95 | 5.98 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.69 | 5.94 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.97 | 7.36 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.02 | 8.58 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.32 | 13.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.28 | 7.30 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.95 | 3.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.32 | 13.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.08 | 11.70 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.68 | 9.39 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.15 | 6.86 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.80 | 3.32 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.59 | 3.91 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.84 | 4.29 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.14 | 7.16 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.95 | 5.98 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.69 | 5.94 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.97 | 7.36 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.02 | 8.58 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.32 | 13.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.28 | 7.30 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.95 | 3.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.32 | 13.06 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.32 | 13.94 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 102.08 | 11.22 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 75.10 | 8.22 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 66.30 | 4.00 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 68.43 | 4.67 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 67.53 | 5.13 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 60.85 | 8.54 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.39 | 7.15 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.08 | 7.08 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 75.02 | 8.77 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 97.77 | 10.23 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.62 | 15.56 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.28 | 8.71 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.39 | 4.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.62 | 15.56 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.19 | 11.42 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.79 | 9.11 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.25 | 6.56 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.95 | 3.09 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.75 | 3.71 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.99 | 4.07 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.25 | 6.91 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.06 | 5.70 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.81 | 5.67 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.09 | 7.08 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.14 | 8.31 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.44 | 12.79 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.40 | 7.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.06 | 3.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.44 | 12.79 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.19 | 11.42 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.79 | 9.11 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.25 | 6.56 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.95 | 3.09 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.75 | 3.71 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.99 | 4.07 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.25 | 6.91 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.06 | 5.70 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.81 | 5.67 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.09 | 7.08 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.14 | 8.31 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.44 | 12.79 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.40 | 7.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.06 | 3.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.44 | 12.79 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.45 | 13.62 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 102.22 | 10.89 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 75.23 | 7.88 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 66.47 | 3.72 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 68.62 | 4.44 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 67.71 | 4.87 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 60.98 | 8.24 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.53 | 6.82 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.22 | 6.77 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 75.16 | 8.44 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 97.92 | 9.91 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.76 | 15.24 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.43 | 8.41 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.53 | 3.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.76 | 15.24 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 99.97 | 10.53 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.48 | 8.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 62.96 | 5.67 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.94 | 2.51 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.66 | 3.14 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.93 | 3.47 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.01 | 6.13 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.86 | 4.81 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.67 | 4.92 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.93 | 6.23 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.94 | 7.47 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.22 | 6.25 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.86 | 2.51 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 99.97 | 10.53 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.48 | 8.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 62.96 | 5.67 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.94 | 2.51 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.66 | 3.14 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.93 | 3.47 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.01 | 6.13 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.86 | 4.81 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.67 | 4.92 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.93 | 6.23 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.94 | 7.47 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.22 | 6.25 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.86 | 2.51 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 99.97 | 10.53 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.48 | 8.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 62.96 | 5.67 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.94 | 2.51 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.66 | 3.14 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.93 | 3.47 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.01 | 6.13 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.86 | 4.81 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.67 | 4.92 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.93 | 6.23 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.94 | 7.47 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.22 | 6.25 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.86 | 2.51 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 99.97 | 10.53 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.48 | 8.18 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 62.96 | 5.67 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 55.94 | 2.51 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 57.66 | 3.14 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 56.93 | 3.47 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.01 | 6.13 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.86 | 4.81 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.67 | 4.92 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.93 | 6.23 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.94 | 7.47 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.22 | 6.25 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.86 | 2.51 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.22 | 11.92 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.20 | 12.56 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 101.86 | 9.78 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 74.91 | 6.81 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 66.46 | 3.02 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 68.54 | 3.75 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 67.64 | 4.15 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 60.71 | 7.31 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.31 | 5.76 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.08 | 5.87 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 74.99 | 7.43 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 97.68 | 8.91 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.53 | 14.21 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.23 | 7.47 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.31 | 3.02 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.53 | 14.21 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.20 | 12.56 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 101.86 | 9.78 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 74.91 | 6.81 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 66.46 | 3.02 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 68.54 | 3.75 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 67.64 | 4.15 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 60.71 | 7.31 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.31 | 5.76 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.08 | 5.87 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 74.99 | 7.43 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 97.68 | 8.91 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.53 | 14.21 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.23 | 7.47 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.31 | 3.02 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.53 | 14.21 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.18 | 10.17 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.77 | 7.78 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.38 | 5.25 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.51 | 2.23 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.23 | 2.88 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.50 | 3.18 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.34 | 5.78 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.22 | 4.43 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.02 | 4.58 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.20 | 5.87 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.17 | 7.12 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.40 | 11.57 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.58 | 5.91 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.22 | 2.23 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.40 | 11.57 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.18 | 10.17 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.77 | 7.78 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.38 | 5.25 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.51 | 2.23 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.23 | 2.88 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.50 | 3.18 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.34 | 5.78 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.22 | 4.43 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.02 | 4.58 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.20 | 5.87 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.17 | 7.12 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.40 | 11.57 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.58 | 5.91 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.22 | 2.23 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.40 | 11.57 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.47 | 12.13 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 102.22 | 9.30 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 75.40 | 6.31 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 67.15 | 2.68 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 69.21 | 3.44 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 68.33 | 3.81 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 61.11 | 6.90 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.73 | 5.31 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.50 | 5.47 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 75.31 | 7.01 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 97.98 | 8.50 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.75 | 13.79 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.67 | 7.06 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.73 | 2.68 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.75 | 13.79 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.24 | 10.09 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.83 | 7.71 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.43 | 5.18 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.58 | 2.18 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.31 | 2.83 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.58 | 3.13 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.39 | 5.71 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.28 | 4.36 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.08 | 4.52 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.26 | 5.80 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.23 | 7.05 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.46 | 11.49 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.65 | 5.84 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.28 | 2.18 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.46 | 11.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.24 | 10.09 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.83 | 7.71 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.43 | 5.18 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.58 | 2.18 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.31 | 2.83 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.58 | 3.13 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.39 | 5.71 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.28 | 4.36 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 55.08 | 4.52 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.26 | 5.80 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.23 | 7.05 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.46 | 11.49 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.65 | 5.84 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.28 | 2.18 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.46 | 11.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.54 | 12.04 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 102.28 | 9.22 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 75.47 | 6.23 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 67.23 | 2.63 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 69.30 | 3.39 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 68.42 | 3.75 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 61.17 | 6.82 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.80 | 5.23 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.56 | 5.40 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 75.39 | 6.92 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 98.05 | 8.41 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.82 | 13.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.75 | 6.98 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.80 | 2.63 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.82 | 13.70 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.21 | 10.08 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.77 | 7.73 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.36 | 5.22 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.45 | 2.22 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.16 | 2.87 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.44 | 3.19 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.30 | 5.78 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.19 | 4.41 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.98 | 4.57 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.21 | 5.81 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.20 | 7.05 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.45 | 11.47 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.57 | 5.87 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.19 | 2.22 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.45 | 11.47 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 100.21 | 10.08 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 85.77 | 7.73 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 63.36 | 5.22 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 56.45 | 2.22 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 58.16 | 2.87 | 0.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 57.44 | 3.19 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 51.30 | 5.78 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 50.19 | 4.41 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 54.98 | 4.57 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 63.21 | 5.81 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 82.20 | 7.05 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 100.45 | 11.47 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 68.57 | 5.87 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 50.19 | 2.22 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 100.45 | 11.47 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 119.50 | 12.03 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 102.21 | 9.25 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 75.37 | 6.28 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 67.07 | 2.68 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 69.13 | 3.44 | 0.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 68.25 | 3.81 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 61.06 | 6.90 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 59.70 | 5.28 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 65.45 | 5.46 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 75.32 | 6.93 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 98.01 | 8.41 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 119.80 | 13.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 81.65 | 7.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 59.70 | 2.68 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 119.80 | 13.68 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 99.37 | 10.44 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 84.71 | 8.24 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 62.17 | 5.79 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 54.83 | 2.72 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 56.55 | 3.32 | 5.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 55.81 | 3.76 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 50.09 | 6.49 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.03 | 5.03 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 53.73 | 5.23 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.32 | 6.27 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.32 | 7.44 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 99.68 | 11.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 67.39 | 6.38 | 5.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.03 | 2.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 99.68 | 11.80 | 5.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 52.63 | 21.95 | 30.68 | 99.37 | 10.44 | 0.00 | 0.00 | 744.00 |
February | 44.69 | 14.56 | 30.12 | 84.71 | 8.24 | 0.00 | 0.00 | 672.00 |
March | 30.49 | 4.08 | 26.41 | 62.17 | 5.79 | 0.00 | 0.00 | 744.00 |
April | 22.74 | 0.01 | 22.73 | 54.83 | 2.72 | 0.00 | 0.00 | 720.00 |
May | 22.76 | 0.00 | 22.76 | 56.55 | 3.32 | 5.00 | 0.00 | 744.00 |
June | 22.68 | 0.00 | 22.68 | 55.81 | 3.76 | 0.00 | 0.00 | 720.00 |
July | 23.36 | 0.00 | 23.36 | 50.09 | 6.49 | 0.00 | 0.00 | 744.00 |
August | 22.74 | 0.03 | 22.71 | 49.03 | 5.03 | 0.00 | 0.00 | 744.00 |
September | 25.17 | 0.82 | 24.35 | 53.73 | 5.23 | 0.00 | 0.00 | 720.00 |
October | 32.93 | 5.25 | 27.69 | 62.32 | 6.27 | 0.00 | 0.00 | 744.00 |
November | 42.82 | 13.06 | 29.76 | 81.32 | 7.44 | 0.00 | 0.00 | 720.00 |
December | 52.61 | 22.38 | 30.23 | 99.68 | 11.80 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.92 | 6.82 | 26.10 | 67.39 | 6.38 | 5.00 | 0.00 | 8760.00 |
Minimum of Months | 22.68 | 0.00 | 22.68 | 49.03 | 2.72 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 52.63 | 22.38 | 30.68 | 99.68 | 11.80 | 5.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.02 | 26.29 | 36.73 | 118.48 | 12.46 | 0.00 | 0.00 | 744.00 |
February | 53.51 | 17.44 | 36.07 | 100.93 | 9.86 | 0.00 | 0.00 | 672.00 |
March | 36.50 | 4.88 | 31.62 | 73.93 | 6.96 | 0.00 | 0.00 | 744.00 |
April | 27.23 | 0.01 | 27.22 | 65.13 | 3.28 | 0.00 | 0.00 | 720.00 |
May | 27.25 | 0.00 | 27.25 | 67.19 | 3.97 | 5.00 | 0.00 | 744.00 |
June | 27.15 | 0.00 | 27.15 | 66.29 | 4.50 | 0.00 | 0.00 | 720.00 |
July | 27.97 | 0.00 | 27.97 | 59.61 | 7.74 | 0.00 | 0.00 | 744.00 |
August | 27.23 | 0.04 | 27.19 | 58.30 | 6.03 | 0.00 | 0.00 | 744.00 |
September | 30.14 | 0.98 | 29.16 | 63.94 | 6.24 | 0.00 | 0.00 | 720.00 |
October | 39.43 | 6.28 | 33.15 | 74.25 | 7.49 | 0.00 | 0.00 | 744.00 |
November | 51.27 | 15.64 | 35.64 | 96.94 | 8.89 | 0.00 | 0.00 | 720.00 |
December | 62.99 | 26.80 | 36.19 | 118.88 | 14.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 39.42 | 8.16 | 31.25 | 80.23 | 7.63 | 5.00 | 0.00 | 8760.00 |
Minimum of Months | 27.15 | 0.00 | 27.15 | 58.30 | 3.28 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 63.02 | 26.80 | 36.73 | 118.88 | 14.07 | 5.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267853E+09 | 25277760.87 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206963E+09 | 17369068.89 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168886E+09 | 13205603.48 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.147581E+09 | 5857306.43 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.157665E+09 | 7407691.41 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149896E+09 | 7892104.20 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.138691E+09 | 14410330.69 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134014E+09 | 11385546.25 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142944E+09 | 11110360.15 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169146E+09 | 14382359.79 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212494E+09 | 17204413.83 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268233E+09 | 29074060.92 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216437E+10 | 0.174577E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134014E+09 | 5857306.43 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268233E+09 | 29074060.92 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267853E+09 | 25277760.87 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206963E+09 | 17369068.89 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168886E+09 | 13205603.48 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.147581E+09 | 5857306.43 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.157665E+09 | 7407691.41 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149896E+09 | 7892104.20 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.138691E+09 | 14410330.69 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134014E+09 | 11385546.25 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142944E+09 | 11110360.15 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169146E+09 | 14382359.79 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212494E+09 | 17204413.83 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268233E+09 | 29074060.92 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216437E+10 | 0.174577E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134014E+09 | 5857306.43 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268233E+09 | 29074060.92 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267853E+09 | 25277760.87 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206963E+09 | 17369068.89 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168886E+09 | 13205603.48 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.147581E+09 | 5857306.43 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.157665E+09 | 7407691.41 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149896E+09 | 7892104.20 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.138691E+09 | 14410330.69 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134014E+09 | 11385546.25 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142944E+09 | 11110360.15 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169146E+09 | 14382359.79 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212494E+09 | 17204413.83 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268233E+09 | 29074060.92 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216437E+10 | 0.174577E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134014E+09 | 5857306.43 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268233E+09 | 29074060.92 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267853E+09 | 25277760.87 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206963E+09 | 17369068.89 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168886E+09 | 13205603.48 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.147581E+09 | 5857306.43 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.157665E+09 | 7407691.41 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149896E+09 | 7892104.20 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.138691E+09 | 14410330.69 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134014E+09 | 11385546.25 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142944E+09 | 11110360.15 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169146E+09 | 14382359.79 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212494E+09 | 17204413.83 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268233E+09 | 29074060.92 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216437E+10 | 0.174577E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134014E+09 | 5857306.43 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268233E+09 | 29074060.92 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.169713E+09 | 70790556.86 | 98922711.46 | 0.321051E+09 | 30436276.10 |
February | 0.130158E+09 | 42417076.15 | 87740844.00 | 0.247874E+09 | 20973062.80 |
March | 98305492.71 | 13151861.11 | 85153631.59 | 0.201847E+09 | 16007443.07 |
April | 70968144.50 | 30556.83 | 70937587.67 | 0.176093E+09 | 7102116.76 |
May | 73385168.34 | 0.00 | 73385168.34 | 0.188197E+09 | 8936942.66 |
June | 70762245.09 | 0.00 | 70762245.09 | 0.178893E+09 | 9520795.17 |
July | 75325640.15 | 0.00 | 75325640.15 | 0.165801E+09 | 17351261.08 |
August | 73328231.96 | 111483.97 | 73216748.00 | 0.160110E+09 | 13753612.77 |
September | 78543910.01 | 2546956.28 | 75996953.73 | 0.170912E+09 | 13395912.77 |
October | 0.106188E+09 | 16913375.08 | 89275051.76 | 0.202531E+09 | 17336271.07 |
November | 0.133632E+09 | 40755222.93 | 92876527.11 | 0.254613E+09 | 20725528.27 |
December | 0.169635E+09 | 72162120.08 | 97472852.63 | 0.321562E+09 | 34969970.71 |
Annual Sum or Average | 0.124995E+10 | 0.258879E+09 | 0.991066E+09 | 0.258948E+10 | 0.210509E+09 |
Minimum of Months | 70762245.09 | 0.00 | 70762245.09 | 0.160110E+09 | 7102116.76 |
Maximum of Months | 0.169713E+09 | 72162120.08 | 98922711.46 | 0.321562E+09 | 34969970.71 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.169713E+09 | 70790556.86 | 98922711.46 | 0.321051E+09 | 30436276.10 |
February | 0.130158E+09 | 42417076.15 | 87740844.00 | 0.247874E+09 | 20973062.80 |
March | 98305492.71 | 13151861.11 | 85153631.59 | 0.201847E+09 | 16007443.07 |
April | 70968144.50 | 30556.83 | 70937587.67 | 0.176093E+09 | 7102116.76 |
May | 73385168.34 | 0.00 | 73385168.34 | 0.188197E+09 | 8936942.66 |
June | 70762245.09 | 0.00 | 70762245.09 | 0.178893E+09 | 9520795.17 |
July | 75325640.15 | 0.00 | 75325640.15 | 0.165801E+09 | 17351261.08 |
August | 73328231.96 | 111483.97 | 73216748.00 | 0.160110E+09 | 13753612.77 |
September | 78543910.01 | 2546956.28 | 75996953.73 | 0.170912E+09 | 13395912.77 |
October | 0.106188E+09 | 16913375.08 | 89275051.76 | 0.202531E+09 | 17336271.07 |
November | 0.133632E+09 | 40755222.93 | 92876527.11 | 0.254613E+09 | 20725528.27 |
December | 0.169635E+09 | 72162120.08 | 97472852.63 | 0.321562E+09 | 34969970.71 |
Annual Sum or Average | 0.124995E+10 | 0.258879E+09 | 0.991066E+09 | 0.258948E+10 | 0.210509E+09 |
Minimum of Months | 70762245.09 | 0.00 | 70762245.09 | 0.160110E+09 | 7102116.76 |
Maximum of Months | 0.169713E+09 | 72162120.08 | 98922711.46 | 0.321562E+09 | 34969970.71 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268909E+09 | 25083991.53 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.208411E+09 | 17078647.26 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.171084E+09 | 12768699.47 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.150049E+09 | 5520421.97 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.159993E+09 | 7191040.12 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.152326E+09 | 7554893.30 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.140391E+09 | 14029494.71 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.135803E+09 | 11033656.75 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.144668E+09 | 10775628.49 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.170375E+09 | 14214419.15 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.213644E+09 | 17046223.86 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269127E+09 | 28929470.34 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.218478E+10 | 0.171227E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.135803E+09 | 5520421.97 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269127E+09 | 28929470.34 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268909E+09 | 25083991.53 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.208411E+09 | 17078647.26 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.171084E+09 | 12768699.47 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.150049E+09 | 5520421.97 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.159993E+09 | 7191040.12 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.152326E+09 | 7554893.30 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.140391E+09 | 14029494.71 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.135803E+09 | 11033656.75 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.144668E+09 | 10775628.49 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.170375E+09 | 14214419.15 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.213644E+09 | 17046223.86 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269127E+09 | 28929470.34 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.218478E+10 | 0.171227E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.135803E+09 | 5520421.97 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269127E+09 | 28929470.34 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.169713E+09 | 70790556.86 | 98922711.46 | 0.322338E+09 | 30190571.62 |
February | 0.130158E+09 | 42417076.15 | 87740844.00 | 0.249614E+09 | 20612003.92 |
March | 98305492.71 | 13151861.11 | 85153631.59 | 0.204470E+09 | 15469018.04 |
April | 70968144.50 | 30556.83 | 70937587.67 | 0.179058E+09 | 6700867.04 |
May | 73385168.34 | 0.00 | 73385168.34 | 0.190996E+09 | 8674950.59 |
June | 70762245.09 | 0.00 | 70762245.09 | 0.181815E+09 | 9114387.68 |
July | 75325640.15 | 0.00 | 75325640.15 | 0.167853E+09 | 16888341.74 |
August | 73328231.96 | 111483.97 | 73216748.00 | 0.162264E+09 | 13326602.21 |
September | 78543910.01 | 2546956.28 | 75996953.73 | 0.172995E+09 | 12989932.25 |
October | 0.106188E+09 | 16913375.08 | 89275051.76 | 0.204024E+09 | 17128163.53 |
November | 0.133632E+09 | 40755222.93 | 92876527.11 | 0.256019E+09 | 20529896.34 |
December | 0.169635E+09 | 72162120.08 | 97472852.63 | 0.322660E+09 | 34782235.05 |
Annual Sum or Average | 0.124995E+10 | 0.258879E+09 | 0.991066E+09 | 0.261411E+10 | 0.206407E+09 |
Minimum of Months | 70762245.09 | 0.00 | 70762245.09 | 0.162264E+09 | 6700867.04 |
Maximum of Months | 0.169713E+09 | 72162120.08 | 98922711.46 | 0.322660E+09 | 34782235.05 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268135E+09 | 30963045.70 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207380E+09 | 22354189.59 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169228E+09 | 17914770.37 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144870E+09 | 8169922.58 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154617E+09 | 10052635.51 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147590E+09 | 10632682.88 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137147E+09 | 18691580.85 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133874E+09 | 15640198.35 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141875E+09 | 14984723.01 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168761E+09 | 19326409.79 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212678E+09 | 21949971.29 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268753E+09 | 34708344.92 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215491E+10 | 0.225388E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133874E+09 | 8169922.58 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268753E+09 | 34708344.92 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268135E+09 | 30963045.70 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207380E+09 | 22354189.59 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169228E+09 | 17914770.37 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144870E+09 | 8169922.58 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154617E+09 | 10052635.51 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147590E+09 | 10632682.88 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137147E+09 | 18691580.85 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133874E+09 | 15640198.35 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141875E+09 | 14984723.01 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168761E+09 | 19326409.79 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212678E+09 | 21949971.29 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268753E+09 | 34708344.92 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215491E+10 | 0.225388E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133874E+09 | 8169922.58 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268753E+09 | 34708344.92 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.319689E+09 | 36914837.47 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.247078E+09 | 26699167.98 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.201275E+09 | 21486682.71 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.172107E+09 | 9833541.22 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.183719E+09 | 12019256.11 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.175337E+09 | 12712569.90 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.163188E+09 | 22290359.11 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.159183E+09 | 18695921.12 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.168829E+09 | 17882857.61 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.201045E+09 | 23033433.82 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.253512E+09 | 26172741.91 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320472E+09 | 41358621.33 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.256543E+10 | 0.269100E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.159183E+09 | 9833541.22 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320472E+09 | 41358621.33 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268045E+09 | 31326841.64 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207282E+09 | 22720425.27 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169128E+09 | 18364517.81 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144646E+09 | 8609198.09 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154248E+09 | 10461835.86 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147339E+09 | 11115267.43 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.136974E+09 | 19188329.25 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133777E+09 | 16020766.27 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141746E+09 | 15387136.99 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168672E+09 | 19715639.57 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212607E+09 | 22231095.12 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268692E+09 | 34973551.32 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215316E+10 | 0.230115E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133777E+09 | 8609198.09 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268692E+09 | 34973551.32 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268045E+09 | 31326841.64 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207282E+09 | 22720425.27 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169128E+09 | 18364517.81 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144646E+09 | 8609198.09 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154248E+09 | 10461835.86 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147339E+09 | 11115267.43 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.136974E+09 | 19188329.25 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133777E+09 | 16020766.27 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141746E+09 | 15387136.99 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168672E+09 | 19715639.57 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212607E+09 | 22231095.12 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268692E+09 | 34973551.32 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215316E+10 | 0.230115E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133777E+09 | 8609198.09 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268692E+09 | 34973551.32 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.319580E+09 | 37346552.49 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.246961E+09 | 27134274.35 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.201156E+09 | 22020356.42 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.171840E+09 | 10356781.55 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.183280E+09 | 12508325.36 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.175040E+09 | 13288344.76 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.162979E+09 | 22881401.49 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.159066E+09 | 19148175.47 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.168675E+09 | 18360448.99 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.200939E+09 | 23496913.10 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.253427E+09 | 26506853.07 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320398E+09 | 41675154.70 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.256334E+10 | 0.274724E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.159066E+09 | 10356781.55 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320398E+09 | 41675154.70 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268344E+09 | 30594737.73 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207549E+09 | 22048056.11 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169418E+09 | 17581372.64 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.145031E+09 | 7997119.81 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154678E+09 | 9935481.24 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147726E+09 | 10552127.20 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137262E+09 | 18506202.14 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134090E+09 | 15265527.68 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142057E+09 | 14707201.52 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168970E+09 | 18961753.54 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212920E+09 | 21540708.21 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269006E+09 | 34251938.01 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215705E+10 | 0.221942E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134090E+09 | 7997119.81 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269006E+09 | 34251938.01 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268344E+09 | 30594737.73 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207549E+09 | 22048056.11 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169418E+09 | 17581372.64 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.145031E+09 | 7997119.81 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154678E+09 | 9935481.24 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147726E+09 | 10552127.20 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137262E+09 | 18506202.14 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134090E+09 | 15265527.68 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142057E+09 | 14707201.52 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168970E+09 | 18961753.54 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212920E+09 | 21540708.21 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269006E+09 | 34251938.01 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215705E+10 | 0.221942E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134090E+09 | 7997119.81 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269006E+09 | 34251938.01 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.319942E+09 | 36483989.47 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.247282E+09 | 26340727.48 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.201505E+09 | 21096782.35 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.172300E+09 | 9632354.98 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.183791E+09 | 11883857.54 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.175500E+09 | 12620259.01 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.163325E+09 | 22074628.87 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.159442E+09 | 18257631.31 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.169048E+09 | 17559087.73 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.201298E+09 | 22607922.49 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.253803E+09 | 25691735.14 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320775E+09 | 40822816.80 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.256801E+10 | 0.265072E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.159442E+09 | 9632354.98 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320775E+09 | 40822816.80 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267757E+09 | 28206153.43 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206783E+09 | 19783282.60 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168643E+09 | 15194962.50 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144985E+09 | 6516112.09 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154449E+09 | 8398323.55 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147554E+09 | 8998397.87 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.136625E+09 | 16419223.13 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133545E+09 | 12876490.20 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141715E+09 | 12752261.72 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168555E+09 | 16680270.70 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212380E+09 | 19361028.01 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268438E+09 | 31934729.29 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215143E+10 | 0.197121E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133545E+09 | 6516112.09 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268438E+09 | 31934729.29 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267757E+09 | 28206153.43 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206783E+09 | 19783282.60 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168643E+09 | 15194962.50 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144985E+09 | 6516112.09 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154449E+09 | 8398323.55 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147554E+09 | 8998397.87 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.136625E+09 | 16419223.13 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133545E+09 | 12876490.20 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141715E+09 | 12752261.72 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168555E+09 | 16680270.70 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212380E+09 | 19361028.01 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268438E+09 | 31934729.29 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215143E+10 | 0.197121E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133545E+09 | 6516112.09 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268438E+09 | 31934729.29 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267757E+09 | 28206153.43 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206783E+09 | 19783282.60 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168643E+09 | 15194962.50 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144985E+09 | 6516112.09 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154449E+09 | 8398323.55 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147554E+09 | 8998397.87 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.136625E+09 | 16419223.13 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133545E+09 | 12876490.20 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141715E+09 | 12752261.72 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168555E+09 | 16680270.70 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212380E+09 | 19361028.01 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268438E+09 | 31934729.29 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215143E+10 | 0.197121E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133545E+09 | 6516112.09 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268438E+09 | 31934729.29 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.267757E+09 | 28206153.43 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.206783E+09 | 19783282.60 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.168643E+09 | 15194962.50 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.144985E+09 | 6516112.09 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.154449E+09 | 8398323.55 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.147554E+09 | 8998397.87 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.136625E+09 | 16419223.13 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.133545E+09 | 12876490.20 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.141715E+09 | 12752261.72 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.168555E+09 | 16680270.70 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212380E+09 | 19361028.01 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268438E+09 | 31934729.29 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.215143E+10 | 0.197121E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.133545E+09 | 6516112.09 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268438E+09 | 31934729.29 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.319276E+09 | 33645947.47 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.246417E+09 | 23648938.67 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.200627E+09 | 18242646.89 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.172276E+09 | 7839828.07 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.183567E+09 | 10045726.56 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.175334E+09 | 10759748.51 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.162610E+09 | 19590808.42 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.158847E+09 | 15414222.97 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.168679E+09 | 15226119.92 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.200845E+09 | 19893223.15 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.253199E+09 | 23099820.33 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320142E+09 | 38072433.56 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.256182E+10 | 0.235479E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.158847E+09 | 7839828.07 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320142E+09 | 38072433.56 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.319276E+09 | 33645947.47 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.246417E+09 | 23648938.67 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.200627E+09 | 18242646.89 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.172276E+09 | 7839828.07 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.183567E+09 | 10045726.56 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.175334E+09 | 10759748.51 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.162610E+09 | 19590808.42 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.158847E+09 | 15414222.97 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.168679E+09 | 15226119.92 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.200845E+09 | 19893223.15 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.253199E+09 | 23099820.33 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320142E+09 | 38072433.56 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.256182E+10 | 0.235479E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.158847E+09 | 7839828.07 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320142E+09 | 38072433.56 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268325E+09 | 27230011.11 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207497E+09 | 18824715.11 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169750E+09 | 14060303.15 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.146472E+09 | 5773482.75 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.155964E+09 | 7703674.68 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149053E+09 | 8246117.44 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137503E+09 | 15475667.84 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134502E+09 | 11862008.65 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142618E+09 | 11878692.04 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169275E+09 | 15732355.21 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212990E+09 | 18459324.68 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268918E+09 | 30985514.95 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216287E+10 | 0.186232E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134502E+09 | 5773482.75 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268918E+09 | 30985514.95 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268325E+09 | 27230011.11 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207497E+09 | 18824715.11 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169750E+09 | 14060303.15 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.146472E+09 | 5773482.75 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.155964E+09 | 7703674.68 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149053E+09 | 8246117.44 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137503E+09 | 15475667.84 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134502E+09 | 11862008.65 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142618E+09 | 11878692.04 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169275E+09 | 15732355.21 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.212990E+09 | 18459324.68 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.268918E+09 | 30985514.95 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216287E+10 | 0.186232E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134502E+09 | 5773482.75 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.268918E+09 | 30985514.95 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.319981E+09 | 32485303.56 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.247279E+09 | 22510563.21 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.201942E+09 | 16899606.99 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.174040E+09 | 6958250.32 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.185371E+09 | 9217897.74 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.177116E+09 | 9862684.34 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.163666E+09 | 18467950.87 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.159993E+09 | 14209091.81 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.169763E+09 | 14186625.33 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.201723E+09 | 18764520.65 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.253954E+09 | 22027108.15 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320744E+09 | 36940401.53 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.257557E+10 | 0.222530E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.159993E+09 | 6958250.32 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320744E+09 | 36940401.53 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268486E+09 | 27030642.79 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207635E+09 | 18654551.78 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169903E+09 | 13876455.42 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.146666E+09 | 5650097.83 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.156169E+09 | 7584509.76 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149248E+09 | 8119112.87 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137652E+09 | 15306270.13 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134657E+09 | 11684529.67 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142768E+09 | 11717595.41 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169432E+09 | 15534249.35 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.213148E+09 | 18270370.69 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269078E+09 | 30777978.24 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216484E+10 | 0.184206E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134657E+09 | 5650097.83 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269078E+09 | 30777978.24 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268486E+09 | 27030642.79 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207635E+09 | 18654551.78 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169903E+09 | 13876455.42 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.146666E+09 | 5650097.83 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.156169E+09 | 7584509.76 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.149248E+09 | 8119112.87 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137652E+09 | 15306270.13 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134657E+09 | 11684529.67 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142768E+09 | 11717595.41 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169432E+09 | 15534249.35 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.213148E+09 | 18270370.69 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269078E+09 | 30777978.24 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216484E+10 | 0.184206E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134657E+09 | 5650097.83 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269078E+09 | 30777978.24 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.320175E+09 | 32247591.83 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.247445E+09 | 22307893.92 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.202126E+09 | 16680851.61 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.174273E+09 | 6810811.65 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.185616E+09 | 9075227.68 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.177349E+09 | 9711389.50 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.163846E+09 | 18266239.57 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.160180E+09 | 13997764.23 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.169944E+09 | 13995199.55 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.201912E+09 | 18528394.11 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.254144E+09 | 21801988.29 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320937E+09 | 36693415.92 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.257795E+10 | 0.220117E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.160180E+09 | 6810811.65 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320937E+09 | 36693415.92 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268409E+09 | 27009648.21 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207492E+09 | 18708374.77 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169700E+09 | 13978214.10 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.146319E+09 | 5763860.76 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.155789E+09 | 7691214.77 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.148881E+09 | 8260380.62 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137401E+09 | 15477978.37 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134431E+09 | 11800598.36 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142516E+09 | 11853485.14 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169299E+09 | 15558316.54 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.213055E+09 | 18264761.66 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269033E+09 | 30732104.07 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216233E+10 | 0.185099E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134431E+09 | 5763860.76 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269033E+09 | 30732104.07 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.268409E+09 | 27009648.21 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.207492E+09 | 18708374.77 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.169700E+09 | 13978214.10 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.146319E+09 | 5763860.76 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.155789E+09 | 7691214.77 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.148881E+09 | 8260380.62 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.137401E+09 | 15477978.37 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.134431E+09 | 11800598.36 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.142516E+09 | 11853485.14 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.169299E+09 | 15558316.54 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.213055E+09 | 18264761.66 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.269033E+09 | 30732104.07 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.216233E+10 | 0.185099E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.134431E+09 | 5763860.76 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.269033E+09 | 30732104.07 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.320080E+09 | 32229999.44 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.247271E+09 | 22378766.18 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.201879E+09 | 16808962.56 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.173853E+09 | 6951515.99 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.185156E+09 | 9206698.18 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.176907E+09 | 9885425.93 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.163542E+09 | 18478246.86 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.159906E+09 | 14142641.04 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.169640E+09 | 14164512.04 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.201749E+09 | 18564435.61 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.254029E+09 | 21801916.16 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.320880E+09 | 36646500.97 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.257489E+10 | 0.221260E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.159906E+09 | 6951515.99 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.320880E+09 | 36646500.97 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.266150E+09 | 27959095.74 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.204921E+09 | 19936831.95 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.166504E+09 | 15511892.04 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.142129E+09 | 7056666.13 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.151466E+09 | 8880872.41 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.144663E+09 | 9738668.94 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.134170E+09 | 17373450.46 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.131322E+09 | 13483588.12 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.139272E+09 | 13547554.11 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.166916E+09 | 16803423.53 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.210772E+09 | 19296768.02 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.266991E+09 | 31605836.49 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.212528E+10 | 0.201195E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.131322E+09 | 7056666.13 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.266991E+09 | 31605836.49 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.140964E+09 | 58798713.89 | 82165312.25 | 0.266150E+09 | 27959095.74 |
February | 0.108109E+09 | 35231669.81 | 72877640.92 | 0.204921E+09 | 19936831.95 |
March | 81652649.68 | 10923950.21 | 70728699.47 | 0.166504E+09 | 15511892.04 |
April | 58946218.38 | 25380.54 | 58920837.84 | 0.142129E+09 | 7056666.13 |
May | 60953801.03 | 0.00 | 60953801.03 | 0.151466E+09 | 8880872.41 |
June | 58775198.11 | 0.00 | 58775198.11 | 0.144663E+09 | 9738668.94 |
July | 62565559.03 | 0.00 | 62565559.03 | 0.134170E+09 | 17373450.46 |
August | 60906509.61 | 92598.71 | 60813910.90 | 0.131322E+09 | 13483588.12 |
September | 65238657.50 | 2115504.67 | 63123152.83 | 0.139272E+09 | 13547554.11 |
October | 88200223.39 | 14048267.82 | 74151955.56 | 0.166916E+09 | 16803423.53 |
November | 0.110995E+09 | 33851332.71 | 77143344.92 | 0.210772E+09 | 19296768.02 |
December | 0.140899E+09 | 59937935.80 | 80961057.92 | 0.266991E+09 | 31605836.49 |
Annual Sum or Average | 0.103821E+10 | 0.215025E+09 | 0.823180E+09 | 0.212528E+10 | 0.201195E+09 |
Minimum of Months | 58775198.11 | 0.00 | 58775198.11 | 0.131322E+09 | 7056666.13 |
Maximum of Months | 0.140964E+09 | 59937935.80 | 82165312.25 | 0.266991E+09 | 31605836.49 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.168786E+09 | 70403723.22 | 98382150.20 | 0.317342E+09 | 33364968.46 |
February | 0.129447E+09 | 42185288.85 | 87261385.84 | 0.244163E+09 | 23848158.17 |
March | 97768304.22 | 13079993.02 | 84688311.20 | 0.198023E+09 | 18639979.23 |
April | 70580340.43 | 30389.86 | 70549950.58 | 0.168817E+09 | 8503485.35 |
May | 72984156.49 | 0.00 | 72984156.49 | 0.179960E+09 | 10633440.44 |
June | 70375566.15 | 0.00 | 70375566.15 | 0.171832E+09 | 11653545.64 |
July | 74914024.63 | 0.00 | 74914024.63 | 0.159646E+09 | 20737171.86 |
August | 72927531.24 | 110874.77 | 72816656.48 | 0.156155E+09 | 16151254.78 |
September | 78114708.32 | 2533038.49 | 75581669.83 | 0.165727E+09 | 16184318.36 |
October | 0.105608E+09 | 16820952.26 | 88787209.95 | 0.198869E+09 | 20051650.79 |
November | 0.132902E+09 | 40532516.80 | 92369005.10 | 0.251264E+09 | 23033406.26 |
December | 0.168708E+09 | 71767791.56 | 96940214.09 | 0.318404E+09 | 37691576.94 |
Annual Sum or Average | 0.124311E+10 | 0.257465E+09 | 0.985650E+09 | 0.253020E+10 | 0.240493E+09 |
Minimum of Months | 70375566.15 | 0.00 | 70375566.15 | 0.156155E+09 | 8503485.35 |
Maximum of Months | 0.168786E+09 | 71767791.56 | 98382150.20 | 0.318404E+09 | 37691576.94 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 639.75 | 60.48 | 337.25 | 140.67 | 196.58 | 0.00 | 0.00 |
February | 547.12 | 46.06 | 286.36 | 93.32 | 193.04 | 0.00 | 0.00 |
March | 402.94 | 31.67 | 195.35 | 26.13 | 169.21 | 0.00 | 0.00 |
April | 363.62 | 14.52 | 145.73 | 0.06 | 145.66 | 0.00 | 0.00 |
May | 375.99 | 17.74 | 145.83 | 0.00 | 145.83 | 0.00 | 0.00 |
June | 369.36 | 19.53 | 145.30 | 0.00 | 145.30 | 0.00 | 0.00 |
July | 330.93 | 34.48 | 149.68 | 0.00 | 149.68 | 0.00 | 0.00 |
August | 319.70 | 27.27 | 145.71 | 0.22 | 145.49 | 0.00 | 0.00 |
September | 352.47 | 27.48 | 161.28 | 5.23 | 156.05 | 0.00 | 0.00 |
October | 403.84 | 34.42 | 211.01 | 33.61 | 177.40 | 0.00 | 0.00 |
November | 524.38 | 42.54 | 274.40 | 83.69 | 190.71 | 0.00 | 0.00 |
December | 640.70 | 69.53 | 337.09 | 143.40 | 193.69 | 0.00 | 0.00 |
Annual Sum or Average | 438.75 | 35.49 | 210.96 | 43.69 | 167.26 | 0.00 | 0.00 |
Minimum of Months | 319.70 | 14.52 | 145.30 | 0.00 | 145.30 | 0.00 | 0.00 |
Maximum of Months | 640.70 | 69.53 | 337.25 | 143.40 | 196.58 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 321.15 | 30.00 | 168.62 | 70.34 | 98.29 | 0.00 | 0.00 |
February | 275.48 | 22.64 | 143.18 | 46.66 | 96.52 | 0.00 | 0.00 |
March | 204.09 | 15.31 | 97.67 | 13.07 | 84.61 | 0.00 | 0.00 |
April | 184.86 | 6.84 | 72.86 | 0.03 | 72.83 | 0.00 | 0.00 |
May | 190.78 | 8.61 | 72.91 | 0.00 | 72.91 | 0.00 | 0.00 |
June | 187.68 | 9.35 | 72.65 | 0.00 | 72.65 | 0.00 | 0.00 |
July | 167.50 | 16.78 | 74.84 | 0.00 | 74.84 | 0.00 | 0.00 |
August | 161.99 | 13.21 | 72.86 | 0.11 | 72.75 | 0.00 | 0.00 |
September | 178.37 | 13.33 | 80.64 | 2.61 | 78.03 | 0.00 | 0.00 |
October | 203.39 | 17.01 | 105.51 | 16.80 | 88.70 | 0.00 | 0.00 |
November | 263.62 | 21.07 | 137.20 | 41.84 | 95.36 | 0.00 | 0.00 |
December | 321.43 | 34.59 | 168.55 | 71.70 | 96.85 | 0.00 | 0.00 |
Annual Sum or Average | 221.45 | 17.40 | 105.48 | 21.85 | 83.63 | 0.00 | 0.00 |
Minimum of Months | 161.99 | 6.84 | 72.65 | 0.00 | 72.65 | 0.00 | 0.00 |
Maximum of Months | 321.43 | 34.59 | 168.62 | 71.70 | 98.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 319.58 | 36.90 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 273.58 | 29.52 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 201.51 | 21.40 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 178.18 | 10.10 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 184.05 | 11.99 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 181.53 | 13.11 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 163.34 | 22.28 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 159.40 | 18.66 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 174.61 | 18.46 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 201.08 | 23.03 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 261.91 | 27.03 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 320.33 | 41.36 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 218.01 | 22.83 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 159.40 | 10.10 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 320.33 | 41.36 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 319.47 | 37.34 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 273.45 | 30.00 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 201.39 | 21.93 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 177.91 | 10.64 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 183.61 | 12.48 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 181.22 | 13.70 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 163.13 | 22.87 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 159.28 | 19.11 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 174.45 | 18.96 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 200.97 | 23.49 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 261.82 | 27.38 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 320.26 | 41.67 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 217.84 | 23.31 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 159.28 | 10.64 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 320.26 | 41.67 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 319.83 | 36.47 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 273.80 | 29.12 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 201.74 | 21.00 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 178.38 | 9.89 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 184.12 | 11.86 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 181.69 | 13.01 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 163.47 | 22.06 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 159.66 | 18.22 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 174.83 | 18.12 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 201.33 | 22.60 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 262.21 | 26.53 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 320.63 | 40.82 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 218.23 | 22.48 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 159.66 | 9.89 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 320.63 | 40.82 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 638.28 | 67.25 | 336.55 | 140.38 | 196.17 | 0.00 | 0.00 |
February | 545.62 | 52.26 | 285.77 | 93.13 | 192.64 | 0.00 | 0.00 |
March | 401.67 | 36.31 | 194.95 | 26.08 | 168.87 | 0.00 | 0.00 |
April | 356.67 | 16.10 | 145.43 | 0.06 | 145.36 | 0.00 | 0.00 |
May | 367.73 | 20.04 | 145.53 | 0.00 | 145.53 | 0.00 | 0.00 |
June | 363.00 | 22.19 | 145.00 | 0.00 | 145.00 | 0.00 | 0.00 |
July | 325.46 | 39.15 | 149.38 | 0.00 | 149.38 | 0.00 | 0.00 |
August | 318.05 | 30.74 | 145.42 | 0.22 | 145.19 | 0.00 | 0.00 |
September | 348.85 | 31.43 | 160.95 | 5.22 | 155.73 | 0.00 | 0.00 |
October | 401.70 | 39.77 | 210.58 | 33.54 | 177.04 | 0.00 | 0.00 |
November | 523.12 | 47.70 | 273.84 | 83.51 | 190.32 | 0.00 | 0.00 |
December | 639.95 | 76.12 | 336.40 | 143.10 | 193.30 | 0.00 | 0.00 |
Annual Sum or Average | 435.35 | 39.94 | 210.52 | 43.60 | 166.92 | 0.00 | 0.00 |
Minimum of Months | 318.05 | 16.10 | 145.00 | 0.00 | 145.00 | 0.00 | 0.00 |
Maximum of Months | 639.95 | 76.12 | 336.55 | 143.10 | 196.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 319.83 | 32.46 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 273.76 | 24.87 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 202.15 | 16.81 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 180.16 | 7.14 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 185.67 | 9.19 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 183.34 | 10.17 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 163.78 | 18.45 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 160.17 | 14.16 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 175.54 | 14.64 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 201.72 | 18.75 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 262.32 | 22.74 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 320.56 | 36.93 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 218.84 | 18.87 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 160.17 | 7.14 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 320.56 | 36.93 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 320.02 | 32.22 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 273.94 | 24.64 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 202.33 | 16.59 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 180.40 | 6.99 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 185.91 | 9.05 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 183.58 | 10.01 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 163.96 | 18.25 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 160.35 | 13.95 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 175.73 | 14.44 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 201.90 | 18.52 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 262.52 | 22.51 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 320.75 | 36.68 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 219.04 | 18.66 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 160.35 | 6.99 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 320.75 | 36.68 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 319.93 | 32.20 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 273.75 | 24.72 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 202.09 | 16.71 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 179.97 | 7.13 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 185.46 | 9.18 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 183.13 | 10.19 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 163.66 | 18.46 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 160.08 | 14.09 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 175.41 | 14.61 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 201.74 | 18.55 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 262.40 | 22.50 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 320.69 | 36.63 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 218.78 | 18.75 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 160.08 | 7.13 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 320.69 | 36.63 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 317.22 | 33.33 | 168.28 | 70.19 | 98.09 | 0.00 | 0.00 |
February | 270.34 | 26.34 | 142.88 | 46.56 | 96.32 | 0.00 | 0.00 |
March | 198.26 | 18.54 | 97.47 | 13.04 | 84.43 | 0.00 | 0.00 |
April | 174.80 | 8.73 | 72.71 | 0.03 | 72.68 | 0.00 | 0.00 |
May | 180.29 | 10.60 | 72.76 | 0.00 | 72.76 | 0.00 | 0.00 |
June | 177.92 | 12.01 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
July | 159.79 | 20.72 | 74.69 | 0.00 | 74.69 | 0.00 | 0.00 |
August | 156.36 | 16.10 | 72.71 | 0.11 | 72.60 | 0.00 | 0.00 |
September | 171.40 | 16.70 | 80.48 | 2.61 | 77.87 | 0.00 | 0.00 |
October | 198.89 | 20.03 | 105.29 | 16.77 | 88.52 | 0.00 | 0.00 |
November | 259.57 | 23.78 | 136.92 | 41.76 | 95.16 | 0.00 | 0.00 |
December | 318.24 | 37.67 | 168.20 | 71.55 | 96.65 | 0.00 | 0.00 |
Annual Sum or Average | 215.02 | 20.39 | 105.26 | 21.80 | 83.46 | 0.00 | 0.00 |
Minimum of Months | 156.36 | 8.73 | 72.50 | 0.00 | 72.50 | 0.00 | 0.00 |
Maximum of Months | 318.24 | 37.67 | 168.28 | 71.55 | 98.09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.171351E+10 | 0.161982E+09 | 0.903283E+09 | 0.376776E+09 | 0.526507E+09 | 0.00 | 0.00 |
February | 0.132360E+10 | 0.111419E+09 | 0.692753E+09 | 0.225761E+09 | 0.466992E+09 | 0.00 | 0.00 |
March | 0.107923E+10 | 84829989.19 | 0.523222E+09 | 69999523.07 | 0.453222E+09 | 0.00 | 0.00 |
April | 0.942509E+09 | 37633049.68 | 0.377721E+09 | 162635.82 | 0.377559E+09 | 0.00 | 0.00 |
May | 0.100705E+10 | 47503893.21 | 0.390586E+09 | 0.00 | 0.390586E+09 | 0.00 | 0.00 |
June | 0.957370E+09 | 50609422.26 | 0.376625E+09 | 0.00 | 0.376625E+09 | 0.00 | 0.00 |
July | 0.886364E+09 | 92341961.51 | 0.400914E+09 | 0.00 | 0.400914E+09 | 0.00 | 0.00 |
August | 0.856272E+09 | 73046815.50 | 0.390283E+09 | 593362.76 | 0.389689E+09 | 0.00 | 0.00 |
September | 0.913599E+09 | 71231859.38 | 0.418042E+09 | 13555931.25 | 0.404487E+09 | 0.00 | 0.00 |
October | 0.108164E+10 | 92201112.29 | 0.565178E+09 | 90019821.45 | 0.475158E+09 | 0.00 | 0.00 |
November | 0.135920E+10 | 0.110268E+09 | 0.711242E+09 | 0.216916E+09 | 0.494326E+09 | 0.00 | 0.00 |
December | 0.171605E+10 | 0.186234E+09 | 0.902866E+09 | 0.384076E+09 | 0.518790E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.138364E+11 | 0.111930E+10 | 0.665271E+10 | 0.137786E+10 | 0.527485E+10 | 0.00 | 0.00 |
Minimum of Months | 0.856272E+09 | 37633049.68 | 0.376625E+09 | 0.00 | 0.376625E+09 | 0.00 | 0.00 |
Maximum of Months | 0.171605E+10 | 0.186234E+09 | 0.903283E+09 | 0.384076E+09 | 0.526507E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.860155E+09 | 80356863.04 | 0.451641E+09 | 0.188388E+09 | 0.263253E+09 | 0.00 | 0.00 |
February | 0.666434E+09 | 54768069.59 | 0.346377E+09 | 0.112880E+09 | 0.233496E+09 | 0.00 | 0.00 |
March | 0.546638E+09 | 41005624.51 | 0.261611E+09 | 34999761.54 | 0.226611E+09 | 0.00 | 0.00 |
April | 0.479156E+09 | 17741144.23 | 0.188861E+09 | 81317.91 | 0.188779E+09 | 0.00 | 0.00 |
May | 0.510983E+09 | 23056846.84 | 0.195293E+09 | 0.00 | 0.195293E+09 | 0.00 | 0.00 |
June | 0.486466E+09 | 24223850.78 | 0.188313E+09 | 0.00 | 0.188313E+09 | 0.00 | 0.00 |
July | 0.448635E+09 | 44946816.03 | 0.200457E+09 | 0.00 | 0.200457E+09 | 0.00 | 0.00 |
August | 0.433870E+09 | 35392762.96 | 0.195141E+09 | 296681.38 | 0.194845E+09 | 0.00 | 0.00 |
September | 0.462331E+09 | 34540628.96 | 0.209021E+09 | 6777965.62 | 0.202243E+09 | 0.00 | 0.00 |
October | 0.544773E+09 | 45556674.88 | 0.282589E+09 | 45009910.72 | 0.237579E+09 | 0.00 | 0.00 |
November | 0.683306E+09 | 54621217.26 | 0.355621E+09 | 0.108458E+09 | 0.247163E+09 | 0.00 | 0.00 |
December | 0.860913E+09 | 92640589.39 | 0.451433E+09 | 0.192038E+09 | 0.259395E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.698366E+10 | 0.548851E+09 | 0.332636E+10 | 0.688930E+09 | 0.263743E+10 | 0.00 | 0.00 |
Minimum of Months | 0.433870E+09 | 17741144.23 | 0.188313E+09 | 0.00 | 0.188313E+09 | 0.00 | 0.00 |
Maximum of Months | 0.860913E+09 | 92640589.39 | 0.451641E+09 | 0.192038E+09 | 0.263253E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.855958E+09 | 98840653.33 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.661837E+09 | 71407183.43 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.539730E+09 | 57316150.79 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.461846E+09 | 26173279.12 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.492952E+09 | 32124258.42 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.470516E+09 | 33977481.10 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.437482E+09 | 59673385.04 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.426931E+09 | 49976133.67 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.452579E+09 | 47852281.36 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.538567E+09 | 61686055.75 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.678867E+09 | 70072524.48 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.857978E+09 | 0.110775E+09 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.687524E+10 | 0.719874E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.426931E+09 | 26173279.12 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.857978E+09 | 0.110775E+09 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.855668E+09 | 99999952.44 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.661525E+09 | 72574802.08 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.539412E+09 | 58749321.51 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.461132E+09 | 27574947.01 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.491776E+09 | 33431565.29 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.469718E+09 | 35518494.24 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.436927E+09 | 61257994.38 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.426621E+09 | 51189554.08 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.452168E+09 | 49134718.00 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.538283E+09 | 62928002.14 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.678642E+09 | 70968809.62 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.857782E+09 | 0.111622E+09 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.686965E+10 | 0.734950E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.426621E+09 | 27574947.01 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.857782E+09 | 0.111622E+09 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.856630E+09 | 97673098.78 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.662379E+09 | 70436261.50 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.540342E+09 | 56259445.46 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.462361E+09 | 25626178.16 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.493147E+09 | 31754591.92 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.470953E+09 | 33724153.63 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.437849E+09 | 59086856.35 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.427621E+09 | 48788513.80 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.453161E+09 | 46973428.98 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.539238E+09 | 60531357.14 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.679643E+09 | 68772970.53 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.858786E+09 | 0.109327E+09 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.688211E+10 | 0.708953E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.427621E+09 | 25626178.16 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.858786E+09 | 0.109327E+09 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.170958E+10 | 0.180115E+09 | 0.901428E+09 | 0.376002E+09 | 0.525426E+09 | 0.00 | 0.00 |
February | 0.131997E+10 | 0.126430E+09 | 0.691331E+09 | 0.225297E+09 | 0.466033E+09 | 0.00 | 0.00 |
March | 0.107582E+10 | 97264473.90 | 0.522147E+09 | 69855786.89 | 0.452291E+09 | 0.00 | 0.00 |
April | 0.924492E+09 | 41743545.10 | 0.376946E+09 | 162301.87 | 0.376783E+09 | 0.00 | 0.00 |
May | 0.984930E+09 | 53683763.87 | 0.389784E+09 | 0.00 | 0.389784E+09 | 0.00 | 0.00 |
June | 0.940883E+09 | 57512600.42 | 0.375852E+09 | 0.00 | 0.375852E+09 | 0.00 | 0.00 |
July | 0.871720E+09 | 0.104858E+09 | 0.400090E+09 | 0.00 | 0.400090E+09 | 0.00 | 0.00 |
August | 0.851875E+09 | 82334112.25 | 0.389481E+09 | 592144.35 | 0.388889E+09 | 0.00 | 0.00 |
September | 0.904219E+09 | 81461077.15 | 0.417184E+09 | 13528095.66 | 0.403656E+09 | 0.00 | 0.00 |
October | 0.107591E+10 | 0.106507E+09 | 0.564017E+09 | 89834975.82 | 0.474182E+09 | 0.00 | 0.00 |
November | 0.135592E+10 | 0.123643E+09 | 0.709782E+09 | 0.216470E+09 | 0.493311E+09 | 0.00 | 0.00 |
December | 0.171404E+10 | 0.203884E+09 | 0.901012E+09 | 0.383287E+09 | 0.517725E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.137294E+11 | 0.125944E+10 | 0.663905E+10 | 0.137503E+10 | 0.526402E+10 | 0.00 | 0.00 |
Minimum of Months | 0.851875E+09 | 41743545.10 | 0.375852E+09 | 0.00 | 0.375852E+09 | 0.00 | 0.00 |
Maximum of Months | 0.171404E+10 | 0.203884E+09 | 0.901428E+09 | 0.383287E+09 | 0.525426E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.856630E+09 | 86944819.87 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.662274E+09 | 60159581.34 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.541443E+09 | 45020068.75 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.466984E+09 | 18504871.19 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.497299E+09 | 24625008.22 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.475222E+09 | 26354758.31 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.438673E+09 | 49419240.13 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.428997E+09 | 37932979.95 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.454998E+09 | 37943915.31 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.540274E+09 | 50229048.15 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.679934E+09 | 58945727.63 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.858580E+09 | 98911170.65 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.690131E+10 | 0.594991E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.428997E+09 | 18504871.19 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.858580E+09 | 98911170.65 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.857147E+09 | 86308373.83 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.662713E+09 | 59616433.96 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.541932E+09 | 44433529.95 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.467604E+09 | 18110731.01 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.497953E+09 | 24244036.04 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.475845E+09 | 25949341.20 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.439150E+09 | 48878758.97 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.429494E+09 | 37366604.63 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.455480E+09 | 37430255.66 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.540775E+09 | 49596784.35 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.680441E+09 | 58342496.81 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.859093E+09 | 98248909.01 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.690763E+10 | 0.588526E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.429494E+09 | 18110731.01 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.859093E+09 | 98248909.01 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.856898E+09 | 86248713.67 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.662255E+09 | 59795167.59 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.541278E+09 | 44765076.63 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.466491E+09 | 18478837.89 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.496734E+09 | 24588995.87 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.474669E+09 | 26406021.12 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.438343E+09 | 49434072.95 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.428768E+09 | 37743654.72 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.454672E+09 | 37871422.04 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.540347E+09 | 49680860.22 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.680140E+09 | 58331399.01 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.858947E+09 | 98110404.46 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.689954E+10 | 0.591455E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.428768E+09 | 18478837.89 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.858947E+09 | 98110404.46 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.849642E+09 | 89282572.55 | 0.450714E+09 | 0.188001E+09 | 0.262713E+09 | 0.00 | 0.00 |
February | 0.654004E+09 | 63720735.10 | 0.345665E+09 | 0.112649E+09 | 0.233017E+09 | 0.00 | 0.00 |
March | 0.531030E+09 | 49662463.38 | 0.261074E+09 | 34927893.44 | 0.226146E+09 | 0.00 | 0.00 |
April | 0.453075E+09 | 22616522.51 | 0.188473E+09 | 81150.93 | 0.188392E+09 | 0.00 | 0.00 |
May | 0.482891E+09 | 28395077.53 | 0.194892E+09 | 0.00 | 0.194892E+09 | 0.00 | 0.00 |
June | 0.461158E+09 | 31130763.47 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
July | 0.427987E+09 | 55484045.66 | 0.200045E+09 | 0.00 | 0.200045E+09 | 0.00 | 0.00 |
August | 0.418799E+09 | 43118161.68 | 0.194741E+09 | 296072.18 | 0.194444E+09 | 0.00 | 0.00 |
September | 0.444270E+09 | 43279327.29 | 0.208592E+09 | 6764047.83 | 0.201828E+09 | 0.00 | 0.00 |
October | 0.532700E+09 | 53657993.58 | 0.282009E+09 | 44917487.91 | 0.237091E+09 | 0.00 | 0.00 |
November | 0.672808E+09 | 61626922.47 | 0.354891E+09 | 0.108235E+09 | 0.246656E+09 | 0.00 | 0.00 |
December | 0.852386E+09 | 0.100903E+09 | 0.450506E+09 | 0.191644E+09 | 0.258862E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.678075E+10 | 0.642878E+09 | 0.331953E+10 | 0.687515E+09 | 0.263201E+10 | 0.00 | 0.00 |
Minimum of Months | 0.418799E+09 | 22616522.51 | 0.187926E+09 | 0.00 | 0.187926E+09 | 0.00 | 0.00 |
Maximum of Months | 0.852386E+09 | 0.100903E+09 | 0.450714E+09 | 0.191644E+09 | 0.262713E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 26.42 | 22.38 | 20.70 | 2.25 | 18.65 | 103.85 | 146.57 | 0.01 |
February | 27.50 | 22.90 | 21.01 | 2.37 | 18.54 | 110.59 | 164.59 | 0.00 |
March | 28.33 | 23.63 | 21.77 | 3.67 | 19.85 | 110.33 | 194.39 | 0.01 |
April | 29.15 | 25.36 | 24.04 | 2.98 | 21.51 | 118.69 | 185.56 | 0.03 |
May | 29.01 | 26.53 | 25.72 | 3.19 | 22.99 | 127.71 | 124.87 | 0.08 |
June | 28.86 | 26.50 | 25.74 | 3.10 | 22.78 | 123.38 | 156.09 | 0.05 |
July | 27.25 | 24.29 | 23.20 | 2.32 | 21.53 | 137.39 | 88.28 | 0.02 |
August | 27.54 | 25.86 | 25.31 | 3.22 | 21.54 | 129.55 | 122.00 | 0.07 |
September | 27.58 | 25.59 | 24.93 | 2.22 | 22.00 | 128.30 | 103.37 | 0.04 |
October | 26.89 | 25.07 | 24.46 | 2.18 | 21.39 | 123.79 | 92.41 | 0.11 |
November | 26.68 | 24.13 | 23.20 | 1.94 | 20.28 | 113.70 | 103.30 | 0.02 |
December | 25.97 | 22.85 | 21.57 | 2.00 | 18.63 | 101.83 | 131.96 | 0.00 |
Annual Sum or Average | 27.59 | 24.59 | 23.48 | 2.62 | 20.82 | 119.14 | 134.17 | 0.04 |
Minimum of Months | 25.97 | 22.38 | 20.70 | 1.94 | 18.54 | 101.83 | 88.28 | 0.00 |
Maximum of Months | 29.15 | 26.53 | 25.74 | 3.67 | 22.99 | 137.39 | 194.39 | 0.11 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 34.10 | 04-JAN-12:00 | 23.66 | 19.40 | 5.00 | 24.66 | 266.50 | 576.50 |
February | 35.00 | 21-FEB-13:00 | 22.00 | 16.00 | 2.10 | 24.16 | 230.00 | 672.50 |
March | 36.40 | 21-MAR-12:00 | 22.99 | 17.00 | 5.00 | 26.97 | 269.50 | 658.50 |
April | 35.50 | 01-APR-13:00 | 26.95 | 24.00 | 2.50 | 27.14 | 295.50 | 519.50 |
May | 37.60 | 06-MAY-12:00 | 26.41 | 22.60 | 4.00 | 29.39 | 317.00 | 525.50 |
June | 36.00 | 12-JUN-14:00 | 27.58 | 25.00 | 4.00 | 28.43 | 235.00 | 472.00 |
July | 33.20 | 15-JUL-15:00 | 25.62 | 23.00 | 2.00 | 27.95 | 219.00 | 181.00 |
August | 34.00 | 10-AUG-13:00 | 27.85 | 26.00 | 5.00 | 26.65 | 344.50 | 278.50 |
September | 34.00 | 06-SEP-13:00 | 26.50 | 24.00 | 4.00 | 25.00 | 258.00 | 581.50 |
October | 33.00 | 04-OCT-13:00 | 26.22 | 24.00 | 4.00 | 25.16 | 303.00 | 428.50 |
November | 34.30 | 18-NOV-12:00 | 25.33 | 22.20 | 3.00 | 25.49 | 289.50 | 511.50 |
December | 33.00 | 07-DEC-13:00 | 23.21 | 19.00 | 3.00 | 22.98 | 215.00 | 596.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 33.00 | 22.00 | 16.00 | 2.00 | 22.98 | 215.00 | 181.00 | |
Maximum of Months | 37.60 | 27.85 | 26.00 | 5.00 | 29.39 | 344.50 | 672.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 18.70 | 23-JAN-05:00 | 16.92 | 16.00 | 2.00 | 7.75 | 0.00 | 0.00 |
February | 20.30 | 21-FEB-09:00 | 19.04 | 18.40 | 2.00 | 10.50 | 258.50 | 564.00 |
March | 22.00 | 03-MAR-05:00 | 19.93 | 19.00 | 3.00 | 13.35 | 0.00 | 0.00 |
April | 22.90 | 14-APR-15:00 | 22.90 | 22.90 | 3.00 | 14.65 | 199.50 | 264.50 |
May | 22.00 | 10-MAY-19:00 | 22.00 | 22.00 | 2.00 | 18.28 | 0.00 | 0.00 |
June | 23.00 | 20-JUN-23:00 | 23.00 | 23.00 | 2.00 | 19.35 | 0.00 | 0.00 |
July | 23.00 | 13-JUL-04:00 | 22.27 | 22.00 | 0.00 | 13.91 | 0.00 | 0.00 |
August | 22.00 | 20-AUG-10:00 | 22.00 | 22.00 | 5.00 | 18.28 | 430.50 | 41.50 |
September | 22.90 | 19-SEP-03:00 | 22.78 | 22.78 | 0.00 | 21.27 | 0.00 | 0.00 |
October | 22.50 | 23-OCT-04:00 | 22.50 | 22.50 | 2.80 | 18.82 | 0.00 | 0.00 |
November | 20.00 | 25-NOV-04:00 | 18.63 | 18.00 | 2.00 | 10.69 | 0.00 | 0.00 |
December | 18.00 | 21-DEC-04:00 | 17.36 | 17.00 | 3.00 | 9.13 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 18.00 | 16.92 | 16.00 | 0.00 | 7.75 | 0.00 | 0.00 | |
Maximum of Months | 23.00 | 23.00 | 23.00 | 5.00 | 21.27 | 430.50 | 564.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 25.52 | 12-JAN-12:00 | 32.40 | 23.10 | 2.00 | 25.00 | 353.00 | 347.00 |
February | 26.16 | 14-FEB-15:00 | 32.30 | 24.20 | 2.00 | 25.16 | 200.00 | 199.00 |
March | 26.27 | 27-MAR-12:00 | 34.20 | 23.60 | 4.00 | 26.32 | 326.00 | 535.00 |
April | 27.92 | 10-APR-16:49 | 31.52 | 26.85 | 4.08 | 27.69 | 110.67 | 57.00 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 30.10 | 15-JUN-09:00 | 33.20 | 29.20 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.42 | 20-JUL-14:00 | 32.80 | 24.20 | 1.00 | 26.65 | 305.00 | 253.00 |
August | 28.81 | 14-AUG-16:00 | 32.00 | 28.00 | 1.00 | 25.16 | 107.50 | 223.00 |
September | 30.05 | 30-SEP-10:00 | 32.80 | 29.40 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 27.36 | 16-OCT-14:00 | 31.50 | 26.00 | 3.00 | 24.16 | 239.00 | 346.50 |
November | 27.55 | 10-NOV-12:00 | 31.00 | 26.40 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.86 | 03-DEC-12:00 | 31.50 | 25.30 | 1.00 | 23.49 | 301.00 | 468.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 25.52 | 29.00 | 23.10 | 1.00 | 22.47 | 0.00 | 0.00 | |
Maximum of Months | 30.10 | 34.20 | 29.40 | 6.00 | 28.11 | 398.00 | 535.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 24.20 | 09-JAN-21:00 | 26.50 | 24.77 | 4.00 | 25.16 | 0.00 | 0.00 |
February | 24.40 | 15-FEB-18:00 | 28.30 | 25.33 | 4.00 | 20.75 | 0.00 | 0.00 |
March | 25.30 | 28-MAR-06:00 | 27.20 | 25.72 | 3.00 | 19.87 | 103.00 | 28.00 |
April | 27.00 | 10-APR-17:00 | 30.50 | 27.86 | 4.50 | 25.00 | 20.00 | 20.50 |
May | 29.00 | 28-MAY-20:00 | 29.00 | 29.00 | 3.00 | 22.47 | 0.00 | 0.00 |
June | 29.20 | 15-JUN-09:00 | 33.20 | 30.10 | 5.00 | 26.48 | 320.50 | 421.00 |
July | 26.00 | 10-JUL-14:00 | 26.50 | 26.11 | 2.30 | 23.49 | 286.00 | 36.50 |
August | 28.00 | 02-AUG-10:00 | 31.00 | 28.65 | 4.00 | 24.16 | 419.00 | 195.50 |
September | 29.40 | 30-SEP-10:00 | 32.80 | 30.05 | 3.00 | 25.66 | 398.00 | 359.50 |
October | 26.50 | 16-OCT-08:00 | 29.00 | 27.03 | 2.50 | 21.78 | 300.00 | 326.00 |
November | 26.40 | 10-NOV-12:00 | 31.00 | 27.55 | 6.00 | 28.11 | 388.00 | 95.50 |
December | 26.00 | 10-DEC-17:00 | 29.00 | 26.74 | 3.00 | 21.78 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.20 | 26.50 | 24.77 | 2.30 | 19.87 | 0.00 | 0.00 | |
Maximum of Months | 29.40 | 33.20 | 30.10 | 6.00 | 28.11 | 419.00 | 421.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 29.71 | 38.82 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 29.90 | 44.34 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 30.35 | 50.49 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 30.97 | 51.18 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 31.58 | 43.47 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 32.02 | 46.77 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 32.16 | 39.95 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 31.97 | 43.65 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 31.50 | 40.53 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 30.87 | 37.35 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 30.27 | 35.77 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 29.84 | 36.19 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 30.93 | 42.35 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 29.71 | 35.77 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 32.16 | 51.18 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.255383E+09 | -143756570.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111626101.5 | 58.99 | 0.00 | 0.00 |
February | 0.230423E+09 | -129696747.6 | 0.00 | 0.00 | 672.00 | 0.00 | -100726477.8 | 58.99 | 0.00 | 0.00 |
March | 0.254928E+09 | -143567173.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111360855.4 | 58.99 | 0.00 | 0.00 |
April | 0.241952E+09 | -134363739.2 | 0.00 | 0.00 | 720.00 | 0.00 | -107588363.4 | 58.99 | 0.00 | 0.00 |
May | 0.247060E+09 | -135939322.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111120422.8 | 58.99 | 0.00 | 0.00 |
June | 0.238189E+09 | -130701838.6 | 0.00 | 0.00 | 720.00 | 0.00 | -107487651.3 | 58.99 | 0.00 | 0.00 |
July | 0.243126E+09 | -131813519.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111312008.6 | 58.99 | 0.00 | 0.00 |
August | 0.246667E+09 | -135366242.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111300309.4 | 58.99 | 0.00 | 0.00 |
September | 0.239689E+09 | -131977278.8 | 0.00 | 0.00 | 720.00 | 0.00 | -107712008.7 | 58.99 | 0.00 | 0.00 |
October | 0.249472E+09 | -138055216.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111416712.0 | 58.99 | 0.00 | 0.00 |
November | 0.243984E+09 | -136099440.9 | 0.00 | 0.00 | 720.00 | 0.00 | -107884432.5 | 58.99 | 0.00 | 0.00 |
December | 0.255011E+09 | -143312109.6 | 0.00 | 0.00 | 744.00 | 0.00 | -111698503.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.294588E+10 | -.163465E+10 | 8760.00 | -.131123E+10 | 58.99 | |||||
Minimum of Months | 0.230423E+09 | -143756570.2 | 0.00 | 0.00 | 672.00 | 0.00 | -111698503.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.255383E+09 | -129696747.6 | 0.00 | 0.00 | 744.00 | 0.00 | -100726477.8 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.255314E+09 | -143755860.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111558308.4 | 58.99 | 0.00 | 0.00 |
February | 0.230392E+09 | -129701766.2 | 0.00 | 0.00 | 672.00 | 0.00 | -100690041.1 | 58.99 | 0.00 | 0.00 |
March | 0.254914E+09 | -143562693.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111351673.2 | 58.99 | 0.00 | 0.00 |
April | 0.241981E+09 | -134365040.1 | 0.00 | 0.00 | 720.00 | 0.00 | -107615542.8 | 58.99 | 0.00 | 0.00 |
May | 0.247081E+09 | -135938510.9 | 0.00 | 0.00 | 744.00 | 0.00 | -111142047.3 | 58.99 | 0.00 | 0.00 |
June | 0.238225E+09 | -130704233.1 | 0.00 | 0.00 | 720.00 | 0.00 | -107520352.7 | 58.99 | 0.00 | 0.00 |
July | 0.243129E+09 | -131815207.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111313886.9 | 58.99 | 0.00 | 0.00 |
August | 0.246674E+09 | -135366629.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111307519.4 | 58.99 | 0.00 | 0.00 |
September | 0.239701E+09 | -131977073.8 | 0.00 | 0.00 | 720.00 | 0.00 | -107723626.1 | 58.99 | 0.00 | 0.00 |
October | 0.249443E+09 | -138054525.6 | 0.00 | 0.00 | 744.00 | 0.00 | -111388796.8 | 58.99 | 0.00 | 0.00 |
November | 0.243942E+09 | -136098306.3 | 0.00 | 0.00 | 720.00 | 0.00 | -107844050.1 | 58.99 | 0.00 | 0.00 |
December | 0.254938E+09 | -143318843.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111619233.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.294573E+10 | -.163466E+10 | 8760.00 | -.131108E+10 | 58.99 | |||||
Minimum of Months | 0.230392E+09 | -143755860.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111619233.3 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.255314E+09 | -129701766.2 | 0.00 | 0.00 | 744.00 | 0.00 | -100690041.1 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.236125E+09 | -126454013.8 | 0.00 | 0.00 | 744.00 | 0.00 | -109670689.8 | 58.98 | 0.00 | 0.00 |
February | 0.213094E+09 | -114146479.8 | 0.00 | 0.00 | 672.00 | 0.00 | -98947244.8 | 58.99 | 0.00 | 0.00 |
March | 0.237679E+09 | -128230817.3 | 0.00 | 0.00 | 744.00 | 0.00 | -109448263.1 | 58.99 | 0.00 | 0.00 |
April | 0.223595E+09 | -118087051.3 | 0.00 | 0.00 | 720.00 | 0.00 | -105508256.8 | 58.99 | 0.00 | 0.00 |
May | 0.229578E+09 | -120555164.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109022610.8 | 58.99 | 0.00 | 0.00 |
June | 0.221977E+09 | -116480889.3 | 0.00 | 0.00 | 720.00 | 0.00 | -105495693.8 | 58.99 | 0.00 | 0.00 |
July | 0.224351E+09 | -115134430.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109216422.3 | 58.99 | 0.00 | 0.00 |
August | 0.230502E+09 | -120984621.5 | 0.00 | 0.00 | 744.00 | 0.00 | -109517805.6 | 58.99 | 0.00 | 0.00 |
September | 0.221705E+09 | -115907211.4 | 0.00 | 0.00 | 720.00 | 0.00 | -105797917.1 | 58.99 | 0.00 | 0.00 |
October | 0.230934E+09 | -121412869.2 | 0.00 | 0.00 | 744.00 | 0.00 | -109520742.0 | 58.99 | 0.00 | 0.00 |
November | 0.226331E+09 | -120165548.3 | 0.00 | 0.00 | 720.00 | 0.00 | -106165103.4 | 58.99 | 0.00 | 0.00 |
December | 0.234965E+09 | -125117094.5 | 0.00 | 0.00 | 744.00 | 0.00 | -109848144.5 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.273084E+10 | -.144268E+10 | 8760.00 | -.128816E+10 | 58.99 | |||||
Minimum of Months | 0.213094E+09 | -128230817.3 | 0.00 | 0.00 | 672.00 | 0.00 | -109848144.5 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.237679E+09 | -114146479.8 | 0.00 | 0.00 | 744.00 | 0.00 | -98947244.8 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.236057E+09 | -126445921.2 | 0.00 | 0.00 | 744.00 | 0.00 | -109611190.7 | 58.99 | 0.00 | 0.00 |
February | 0.213026E+09 | -114148437.0 | 0.00 | 0.00 | 672.00 | 0.00 | -98877742.5 | 58.99 | 0.00 | 0.00 |
March | 0.237595E+09 | -128224789.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109370013.4 | 58.99 | 0.00 | 0.00 |
April | 0.223507E+09 | -118094696.5 | 0.00 | 0.00 | 720.00 | 0.00 | -105412549.1 | 58.99 | 0.00 | 0.00 |
May | 0.229448E+09 | -120546436.7 | 0.00 | 0.00 | 744.00 | 0.00 | -108901245.3 | 58.99 | 0.00 | 0.00 |
June | 0.221884E+09 | -116526382.4 | 0.00 | 0.00 | 720.00 | 0.00 | -105357926.7 | 58.98 | 0.00 | 0.00 |
July | 0.224267E+09 | -115180549.4 | 0.00 | 0.00 | 744.00 | 0.00 | -109086430.9 | 58.98 | 0.00 | 0.00 |
August | 0.230432E+09 | -121015324.4 | 0.00 | 0.00 | 744.00 | 0.00 | -109416462.9 | 58.98 | 0.00 | 0.00 |
September | 0.221620E+09 | -115907031.5 | 0.00 | 0.00 | 720.00 | 0.00 | -105712826.7 | 58.99 | 0.00 | 0.00 |
October | 0.230851E+09 | -121391073.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109459555.9 | 58.99 | 0.00 | 0.00 |
November | 0.226282E+09 | -120168004.5 | 0.00 | 0.00 | 720.00 | 0.00 | -106114172.6 | 58.99 | 0.00 | 0.00 |
December | 0.234918E+09 | -125115165.1 | 0.00 | 0.00 | 744.00 | 0.00 | -109802609.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.272989E+10 | -.144276E+10 | 8760.00 | -.128712E+10 | 58.99 | |||||
Minimum of Months | 0.213026E+09 | -128224789.6 | 0.00 | 0.00 | 672.00 | 0.00 | -109802609.3 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.237595E+09 | -114148437.0 | 0.00 | 0.00 | 744.00 | 0.00 | -98877742.5 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.229700E+09 | -119478935.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110221456.3 | 58.99 | 0.00 | 0.00 |
February | 0.207361E+09 | -107953653.9 | 0.00 | 0.00 | 672.00 | 0.00 | -99407457.9 | 58.99 | 0.00 | 0.00 |
March | 0.231335E+09 | -121313580.0 | 0.00 | 0.00 | 744.00 | 0.00 | -110021193.6 | 58.99 | 0.00 | 0.00 |
April | 0.217743E+09 | -111728439.4 | 0.00 | 0.00 | 720.00 | 0.00 | -106014191.8 | 58.99 | 0.00 | 0.00 |
May | 0.223435E+09 | -114011653.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109422896.4 | 58.99 | 0.00 | 0.00 |
June | 0.216186E+09 | -110288548.0 | 0.00 | 0.00 | 720.00 | 0.00 | -105897241.3 | 58.97 | 0.00 | 0.00 |
July | 0.218539E+09 | -108937298.3 | 0.00 | 0.00 | 744.00 | 0.00 | -109601621.7 | 58.99 | 0.00 | 0.00 |
August | 0.224508E+09 | -114462396.0 | 0.00 | 0.00 | 744.00 | 0.00 | -110045930.9 | 58.99 | 0.00 | 0.00 |
September | 0.215934E+09 | -109665003.0 | 0.00 | 0.00 | 720.00 | 0.00 | -106268583.4 | 59.00 | 0.00 | 0.00 |
October | 0.224736E+09 | -114740133.4 | 0.00 | 0.00 | 744.00 | 0.00 | -109995639.8 | 58.99 | 0.00 | 0.00 |
November | 0.220146E+09 | -113494561.7 | 0.00 | 0.00 | 720.00 | 0.00 | -106651365.0 | 58.99 | 0.00 | 0.00 |
December | 0.228671E+09 | -118327016.1 | 0.00 | 0.00 | 744.00 | 0.00 | -110344430.0 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.265829E+10 | -.136440E+10 | 8760.00 | -.129389E+10 | 58.99 | |||||
Minimum of Months | 0.207361E+09 | -121313580.0 | 0.00 | 0.00 | 672.00 | 0.00 | -110344430.0 | 58.97 | 0.00 | 0.00 |
Maximum of Months | 0.231335E+09 | -107953653.9 | 0.00 | 0.00 | 744.00 | 0.00 | -99407457.9 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.229838E+09 | -119482716.0 | 0.00 | 0.00 | 744.00 | 0.00 | -110354950.5 | 58.99 | 0.00 | 0.00 |
February | 0.207494E+09 | -107946728.0 | 0.00 | 0.00 | 672.00 | 0.00 | -99547264.0 | 58.99 | 0.00 | 0.00 |
March | 0.231472E+09 | -121326808.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110145494.4 | 58.99 | 0.00 | 0.00 |
April | 0.217904E+09 | -111746082.3 | 0.00 | 0.00 | 720.00 | 0.00 | -106157677.0 | 58.99 | 0.00 | 0.00 |
May | 0.223592E+09 | -113986780.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109605255.8 | 58.99 | 0.00 | 0.00 |
June | 0.216349E+09 | -110224289.4 | 0.00 | 0.00 | 720.00 | 0.00 | -106124406.1 | 58.99 | 0.00 | 0.00 |
July | 0.218672E+09 | -108866891.8 | 0.00 | 0.00 | 744.00 | 0.00 | -109805190.1 | 59.00 | 0.00 | 0.00 |
August | 0.224647E+09 | -114416724.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110230262.9 | 59.01 | 0.00 | 0.00 |
September | 0.216079E+09 | -109670026.0 | 0.00 | 0.00 | 720.00 | 0.00 | -106409319.5 | 58.99 | 0.00 | 0.00 |
October | 0.224880E+09 | -114723994.1 | 0.00 | 0.00 | 744.00 | 0.00 | -110155862.7 | 58.99 | 0.00 | 0.00 |
November | 0.220281E+09 | -113499269.2 | 0.00 | 0.00 | 720.00 | 0.00 | -106781832.6 | 58.99 | 0.00 | 0.00 |
December | 0.228804E+09 | -118321766.3 | 0.00 | 0.00 | 744.00 | 0.00 | -110481902.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.266001E+10 | -.136421E+10 | 8760.00 | -.129580E+10 | 58.99 | |||||
Minimum of Months | 0.207494E+09 | -121326808.9 | 0.00 | 0.00 | 672.00 | 0.00 | -110481902.1 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.231472E+09 | -107946728.0 | 0.00 | 0.00 | 744.00 | 0.00 | -99547264.0 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.229877E+09 | -119485327.4 | 0.00 | 0.00 | 744.00 | 0.00 | -110391296.1 | 58.99 | 0.00 | 0.00 |
February | 0.207527E+09 | -107942316.5 | 0.00 | 0.00 | 672.00 | 0.00 | -99584336.3 | 58.99 | 0.00 | 0.00 |
March | 0.231508E+09 | -121325724.3 | 0.00 | 0.00 | 744.00 | 0.00 | -110182393.9 | 58.99 | 0.00 | 0.00 |
April | 0.217938E+09 | -111750333.1 | 0.00 | 0.00 | 720.00 | 0.00 | -106187906.7 | 58.99 | 0.00 | 0.00 |
May | 0.223621E+09 | -113983085.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109637595.5 | 58.99 | 0.00 | 0.00 |
June | 0.216393E+09 | -110271420.2 | 0.00 | 0.00 | 720.00 | 0.00 | -106121570.3 | 58.98 | 0.00 | 0.00 |
July | 0.218720E+09 | -108914014.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109805501.1 | 58.99 | 0.00 | 0.00 |
August | 0.224695E+09 | -114481083.1 | 0.00 | 0.00 | 744.00 | 0.00 | -110213526.7 | 58.99 | 0.00 | 0.00 |
September | 0.216112E+09 | -109676651.8 | 0.00 | 0.00 | 720.00 | 0.00 | -106435142.1 | 58.99 | 0.00 | 0.00 |
October | 0.224924E+09 | -114719360.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110204234.8 | 59.00 | 0.00 | 0.00 |
November | 0.220320E+09 | -113502451.4 | 0.00 | 0.00 | 720.00 | 0.00 | -106817492.6 | 58.99 | 0.00 | 0.00 |
December | 0.228842E+09 | -118340094.3 | 0.00 | 0.00 | 744.00 | 0.00 | -110502325.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.266048E+10 | -.136439E+10 | 8760.00 | -.129608E+10 | 58.99 | |||||
Minimum of Months | 0.207527E+09 | -121325724.3 | 0.00 | 0.00 | 672.00 | 0.00 | -110502325.9 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.231508E+09 | -107942316.5 | 0.00 | 0.00 | 744.00 | 0.00 | -99584336.3 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 350.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 321.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 361.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 358.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 376.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 370.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 383.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 369.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 357.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 356.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 337.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 349.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4292.33 | ||||||||||
Minimum of Months | 321.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 383.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.418293E+11 | 0.259145E+11 | 57997.92 | 10-JAN-08:62 | 30732.39 | 0.00 |
February | 0.00 | 0.00 | 0.406299E+11 | 0.252254E+11 | 57791.06 | 16-FEB-08:62 | 31474.41 | 0.00 |
March | 0.00 | 0.00 | 0.475407E+11 | 0.291631E+11 | 58684.89 | 28-MAR-07:01 | 29837.05 | 0.00 |
April | 0.00 | 0.00 | 0.528351E+11 | 0.295988E+11 | 58843.78 | 12-APR-07:01 | 29656.76 | 0.00 |
May | 0.00 | 0.00 | 0.591758E+11 | 0.306446E+11 | 60020.83 | 19-MAY-07:01 | 25447.90 | 0.00 |
June | 0.00 | 0.00 | 0.588642E+11 | 0.303676E+11 | 59998.31 | 10-JUN-07:01 | 26036.10 | 0.00 |
July | 0.00 | 0.00 | 0.480781E+11 | 0.268047E+11 | 58451.02 | 01-JUL-07:02 | 29538.70 | 0.00 |
August | 0.00 | 0.00 | 0.541397E+11 | 0.268951E+11 | 59926.31 | 11-AUG-07:01 | 26637.29 | 0.00 |
September | 0.00 | 0.00 | 0.516752E+11 | 0.264570E+11 | 59104.58 | 01-SEP-07:02 | 28586.61 | 0.00 |
October | 0.00 | 0.00 | 0.492827E+11 | 0.251549E+11 | 58704.65 | 14-OCT-07:02 | 28448.33 | 0.00 |
November | 0.00 | 0.00 | 0.451494E+11 | 0.244984E+11 | 58365.82 | 12-NOV-08:62 | 30025.14 | 0.00 |
December | 0.00 | 0.00 | 0.427065E+11 | 0.250942E+11 | 57789.75 | 11-DEC-08:62 | 31356.45 | 0.00 |
Annual Sum or Average | 0.591907E+12 | 0.325818E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.406299E+11 | 0.244984E+11 | 57789.75 | 25447.90 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.591758E+11 | 0.306446E+11 | 60020.83 | 31474.41 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.206840E+11 | 0.132037E+11 | 29476.53 | 10-JAN-08:62 | 18383.94 | 0.00 |
February | 0.00 | 0.00 | 0.199529E+11 | 0.127115E+11 | 29403.39 | 16-FEB-08:62 | 18613.10 | 0.00 |
March | 0.00 | 0.00 | 0.231870E+11 | 0.145947E+11 | 29798.95 | 28-MAR-07:01 | 17813.98 | 0.00 |
April | 0.00 | 0.00 | 0.255848E+11 | 0.147276E+11 | 29909.15 | 12-APR-07:01 | 17614.19 | 0.00 |
May | 0.00 | 0.00 | 0.287956E+11 | 0.153592E+11 | 30665.00 | 22-MAY-07:01 | 15614.06 | 0.00 |
June | 0.00 | 0.00 | 0.286676E+11 | 0.152006E+11 | 30638.85 | 14-JUN-07:01 | 16045.70 | 0.00 |
July | 0.00 | 0.00 | 0.234737E+11 | 0.134755E+11 | 29555.75 | 01-JUL-07:02 | 18146.04 | 0.00 |
August | 0.00 | 0.00 | 0.264937E+11 | 0.135738E+11 | 30352.74 | 11-AUG-07:01 | 16399.16 | 0.00 |
September | 0.00 | 0.00 | 0.252000E+11 | 0.133117E+11 | 29940.81 | 01-SEP-07:02 | 17299.38 | 0.00 |
October | 0.00 | 0.00 | 0.242568E+11 | 0.128195E+11 | 29742.63 | 05-OCT-07:02 | 17849.33 | 0.00 |
November | 0.00 | 0.00 | 0.222379E+11 | 0.124813E+11 | 29501.01 | 12-NOV-08:62 | 18410.67 | 0.00 |
December | 0.00 | 0.00 | 0.211144E+11 | 0.128532E+11 | 29276.07 | 10-DEC-08:61 | 19125.99 | 0.00 |
Annual Sum or Average | 0.289648E+12 | 0.164312E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.199529E+11 | 0.124813E+11 | 29276.07 | 15614.06 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.287956E+11 | 0.153592E+11 | 30665.00 | 19125.99 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.170212E+11 | 0.106213E+11 | 31319.64 | 02-JAN-07:02 | 13557.87 | 0.00 |
February | 0.00 | 0.00 | 0.165565E+11 | 0.103133E+11 | 31059.80 | 06-FEB-07:02 | 14376.68 | 0.00 |
March | 0.00 | 0.00 | 0.195586E+11 | 0.120405E+11 | 31491.85 | 27-MAR-06:01 | 13895.82 | 0.00 |
April | 0.00 | 0.00 | 0.213451E+11 | 0.119567E+11 | 31556.05 | 10-APR-06:02 | 13097.42 | 0.00 |
May | 0.00 | 0.00 | 0.243975E+11 | 0.125947E+11 | 31629.50 | 17-MAY-06:01 | 12623.12 | 0.00 |
June | 0.00 | 0.00 | 0.244894E+11 | 0.125654E+11 | 31626.01 | 26-JUN-06:01 | 11618.05 | 0.00 |
July | 0.00 | 0.00 | 0.193758E+11 | 0.106780E+11 | 31580.79 | 02-JUL-07:01 | 13642.71 | 0.00 |
August | 0.00 | 0.00 | 0.225983E+11 | 0.111100E+11 | 31627.78 | 21-AUG-06:02 | 11837.33 | 0.00 |
September | 0.00 | 0.00 | 0.211080E+11 | 0.106934E+11 | 31628.30 | 18-SEP-06:02 | 11874.88 | 0.00 |
October | 0.00 | 0.00 | 0.202841E+11 | 0.102686E+11 | 31629.08 | 02-OCT-06:02 | 12790.73 | 0.00 |
November | 0.00 | 0.00 | 0.185167E+11 | 0.100740E+11 | 31583.93 | 13-NOV-07:02 | 12278.49 | 0.00 |
December | 0.00 | 0.00 | 0.172753E+11 | 0.102771E+11 | 31623.41 | 11-DEC-07:02 | 11976.94 | 0.00 |
Annual Sum or Average | 0.242526E+12 | 0.133193E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.165565E+11 | 0.100740E+11 | 31059.80 | 11618.05 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.244894E+11 | 0.125947E+11 | 31629.50 | 14376.68 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.170612E+11 | 0.106512E+11 | 31419.39 | 02-JAN-07:02 | 13629.62 | 0.00 |
February | 0.00 | 0.00 | 0.165982E+11 | 0.103448E+11 | 31161.66 | 06-FEB-07:02 | 14465.29 | 0.00 |
March | 0.00 | 0.00 | 0.196072E+11 | 0.120770E+11 | 31600.06 | 27-MAR-06:01 | 14014.29 | 0.00 |
April | 0.00 | 0.00 | 0.214073E+11 | 0.120019E+11 | 31657.00 | 10-APR-06:02 | 13175.68 | 0.00 |
May | 0.00 | 0.00 | 0.244810E+11 | 0.126542E+11 | 31725.64 | 17-MAY-06:01 | 12696.44 | 0.00 |
June | 0.00 | 0.00 | 0.245664E+11 | 0.126209E+11 | 31722.15 | 26-JUN-06:01 | 11711.63 | 0.00 |
July | 0.00 | 0.00 | 0.194442E+11 | 0.107265E+11 | 31676.78 | 02-JUL-07:01 | 13723.83 | 0.00 |
August | 0.00 | 0.00 | 0.226415E+11 | 0.111411E+11 | 31723.92 | 21-AUG-06:02 | 11878.62 | 0.00 |
September | 0.00 | 0.00 | 0.211581E+11 | 0.107293E+11 | 31724.44 | 18-SEP-06:02 | 11935.16 | 0.00 |
October | 0.00 | 0.00 | 0.203286E+11 | 0.102999E+11 | 31725.22 | 02-OCT-06:02 | 12877.51 | 0.00 |
November | 0.00 | 0.00 | 0.185429E+11 | 0.100939E+11 | 31679.94 | 13-NOV-07:02 | 12348.93 | 0.00 |
December | 0.00 | 0.00 | 0.172996E+11 | 0.102956E+11 | 31719.54 | 11-DEC-07:02 | 12059.90 | 0.00 |
Annual Sum or Average | 0.243136E+12 | 0.133636E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.165982E+11 | 0.100939E+11 | 31161.66 | 11711.63 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.245664E+11 | 0.126542E+11 | 31725.64 | 14465.29 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.168268E+11 | 0.104763E+11 | 31135.68 | 02-JAN-07:02 | 13425.25 | 0.00 |
February | 0.00 | 0.00 | 0.163862E+11 | 0.101857E+11 | 30879.63 | 06-FEB-07:02 | 14259.77 | 0.00 |
March | 0.00 | 0.00 | 0.193637E+11 | 0.118954E+11 | 31315.76 | 27-MAR-06:01 | 13818.79 | 0.00 |
April | 0.00 | 0.00 | 0.211676E+11 | 0.118292E+11 | 31372.06 | 10-APR-06:02 | 12975.47 | 0.00 |
May | 0.00 | 0.00 | 0.242397E+11 | 0.124851E+11 | 31448.84 | 17-MAY-06:01 | 12472.37 | 0.00 |
June | 0.00 | 0.00 | 0.243282E+11 | 0.124525E+11 | 31445.37 | 26-JUN-06:01 | 11534.97 | 0.00 |
July | 0.00 | 0.00 | 0.192052E+11 | 0.105567E+11 | 31399.83 | 02-JUL-07:01 | 13498.36 | 0.00 |
August | 0.00 | 0.00 | 0.223685E+11 | 0.109560E+11 | 31447.13 | 21-AUG-06:02 | 11667.59 | 0.00 |
September | 0.00 | 0.00 | 0.209073E+11 | 0.105566E+11 | 31447.64 | 18-SEP-06:02 | 11732.68 | 0.00 |
October | 0.00 | 0.00 | 0.200678E+11 | 0.101219E+11 | 31448.42 | 02-OCT-06:02 | 12689.86 | 0.00 |
November | 0.00 | 0.00 | 0.182971E+11 | 0.992066E+10 | 31403.53 | 13-NOV-07:02 | 12154.85 | 0.00 |
December | 0.00 | 0.00 | 0.170547E+11 | 0.101170E+11 | 31442.79 | 11-DEC-07:02 | 11880.15 | 0.00 |
Annual Sum or Average | 0.240213E+12 | 0.131553E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.163862E+11 | 0.992066E+10 | 30879.63 | 11534.97 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.243282E+11 | 0.124851E+11 | 31448.84 | 14259.77 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.297943E+11 | 0.182770E+11 | 54316.71 | 02-JAN-08:62 | 23533.60 | 0.00 |
February | 0.00 | 0.00 | 0.290848E+11 | 0.178157E+11 | 53856.14 | 06-FEB-08:62 | 25236.54 | 0.00 |
March | 0.00 | 0.00 | 0.344022E+11 | 0.208533E+11 | 54627.43 | 27-MAR-07:01 | 24195.63 | 0.00 |
April | 0.00 | 0.00 | 0.377056E+11 | 0.207286E+11 | 54694.54 | 10-APR-07:02 | 22460.53 | 0.00 |
May | 0.00 | 0.00 | 0.433677E+11 | 0.219174E+11 | 54664.04 | 15-MAY-07:01 | 20350.14 | 0.00 |
June | 0.00 | 0.00 | 0.437039E+11 | 0.219588E+11 | 54722.26 | 26-JUN-07:02 | 20058.14 | 0.00 |
July | 0.00 | 0.00 | 0.339109E+11 | 0.182790E+11 | 54679.64 | 02-JUL-08:61 | 23440.17 | 0.00 |
August | 0.00 | 0.00 | 0.398548E+11 | 0.190314E+11 | 54784.17 | 21-AUG-07:02 | 20014.24 | 0.00 |
September | 0.00 | 0.00 | 0.371016E+11 | 0.183123E+11 | 54846.26 | 18-SEP-07:02 | 20309.66 | 0.00 |
October | 0.00 | 0.00 | 0.354528E+11 | 0.174326E+11 | 54815.98 | 02-OCT-07:02 | 22053.92 | 0.00 |
November | 0.00 | 0.00 | 0.323364E+11 | 0.171272E+11 | 54709.10 | 20-NOV-08:61 | 23505.81 | 0.00 |
December | 0.00 | 0.00 | 0.300266E+11 | 0.175016E+11 | 54758.63 | 11-DEC-08:62 | 21039.22 | 0.00 |
Annual Sum or Average | 0.426742E+12 | 0.229235E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.290848E+11 | 0.171272E+11 | 53856.14 | 20014.24 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.437039E+11 | 0.219588E+11 | 54846.26 | 25236.54 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.154355E+11 | 0.947576E+10 | 28579.45 | 02-JAN-08:62 | 12319.55 | 0.00 |
February | 0.00 | 0.00 | 0.150804E+11 | 0.924088E+10 | 28329.25 | 06-FEB-08:62 | 13209.06 | 0.00 |
March | 0.00 | 0.00 | 0.178295E+11 | 0.108128E+11 | 28732.23 | 27-MAR-07:01 | 12677.17 | 0.00 |
April | 0.00 | 0.00 | 0.195466E+11 | 0.107527E+11 | 28750.07 | 10-APR-07:02 | 11729.30 | 0.00 |
May | 0.00 | 0.00 | 0.224705E+11 | 0.113679E+11 | 28734.04 | 15-MAY-07:01 | 10599.69 | 0.00 |
June | 0.00 | 0.00 | 0.226287E+11 | 0.113771E+11 | 28764.64 | 26-JUN-07:02 | 10452.80 | 0.00 |
July | 0.00 | 0.00 | 0.175525E+11 | 0.947034E+10 | 28753.35 | 05-JUL-07:01 | 12272.90 | 0.00 |
August | 0.00 | 0.00 | 0.206124E+11 | 0.985355E+10 | 28797.18 | 21-AUG-07:02 | 10451.73 | 0.00 |
September | 0.00 | 0.00 | 0.192070E+11 | 0.948845E+10 | 28829.82 | 18-SEP-07:02 | 10566.87 | 0.00 |
October | 0.00 | 0.00 | 0.183458E+11 | 0.903073E+10 | 28829.05 | 23-OCT-07:02 | 11126.33 | 0.00 |
November | 0.00 | 0.00 | 0.167297E+11 | 0.886948E+10 | 28777.75 | 20-NOV-08:61 | 12216.41 | 0.00 |
December | 0.00 | 0.00 | 0.155426E+11 | 0.906613E+10 | 28783.76 | 11-DEC-08:62 | 10925.10 | 0.00 |
Annual Sum or Average | 0.220981E+12 | 0.118806E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.150804E+11 | 0.886948E+10 | 28329.25 | 10451.73 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.226287E+11 | 0.113771E+11 | 28829.82 | 13209.06 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.153576E+11 | 0.941903E+10 | 28434.56 | 02-JAN-08:62 | 12239.99 | 0.00 |
February | 0.00 | 0.00 | 0.150139E+11 | 0.919199E+10 | 28185.45 | 06-FEB-08:62 | 13126.86 | 0.00 |
March | 0.00 | 0.00 | 0.177546E+11 | 0.107583E+11 | 28587.50 | 27-MAR-07:01 | 12601.20 | 0.00 |
April | 0.00 | 0.00 | 0.194755E+11 | 0.107024E+11 | 28605.39 | 10-APR-07:02 | 11652.59 | 0.00 |
May | 0.00 | 0.00 | 0.223951E+11 | 0.113157E+11 | 28589.44 | 15-MAY-07:01 | 10533.32 | 0.00 |
June | 0.00 | 0.00 | 0.225530E+11 | 0.113243E+11 | 28619.89 | 26-JUN-07:02 | 10382.27 | 0.00 |
July | 0.00 | 0.00 | 0.174792E+11 | 0.941937E+10 | 28607.84 | 05-JUL-07:01 | 12195.36 | 0.00 |
August | 0.00 | 0.00 | 0.205330E+11 | 0.980071E+10 | 28652.26 | 21-AUG-07:02 | 10374.96 | 0.00 |
September | 0.00 | 0.00 | 0.191338E+11 | 0.943901E+10 | 28684.74 | 18-SEP-07:02 | 10493.88 | 0.00 |
October | 0.00 | 0.00 | 0.182646E+11 | 0.897669E+10 | 28682.55 | 23-OCT-07:02 | 11047.89 | 0.00 |
November | 0.00 | 0.00 | 0.166499E+11 | 0.881472E+10 | 28632.93 | 20-NOV-08:61 | 12138.45 | 0.00 |
December | 0.00 | 0.00 | 0.154627E+11 | 0.900919E+10 | 28638.91 | 11-DEC-08:62 | 10852.80 | 0.00 |
Annual Sum or Average | 0.220073E+12 | 0.118171E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.150139E+11 | 0.881472E+10 | 28185.45 | 10374.96 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.225530E+11 | 0.113243E+11 | 28684.74 | 13126.86 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.153543E+11 | 0.941722E+10 | 28507.66 | 02-JAN-08:62 | 12229.34 | 0.00 |
February | 0.00 | 0.00 | 0.150399E+11 | 0.921151E+10 | 28259.99 | 06-FEB-08:62 | 13136.01 | 0.00 |
March | 0.00 | 0.00 | 0.177915E+11 | 0.107867E+11 | 28665.21 | 27-MAR-07:01 | 12622.32 | 0.00 |
April | 0.00 | 0.00 | 0.195329E+11 | 0.107457E+11 | 28687.46 | 10-APR-07:02 | 11654.97 | 0.00 |
May | 0.00 | 0.00 | 0.224517E+11 | 0.113586E+11 | 28671.46 | 15-MAY-07:01 | 10561.50 | 0.00 |
June | 0.00 | 0.00 | 0.226233E+11 | 0.113761E+11 | 28702.00 | 26-JUN-07:02 | 10388.61 | 0.00 |
July | 0.00 | 0.00 | 0.175216E+11 | 0.945018E+10 | 28685.56 | 05-JUL-07:01 | 12213.40 | 0.00 |
August | 0.00 | 0.00 | 0.205649E+11 | 0.982605E+10 | 28734.47 | 21-AUG-07:02 | 10344.60 | 0.00 |
September | 0.00 | 0.00 | 0.191752E+11 | 0.947014E+10 | 28767.04 | 18-SEP-07:02 | 10490.97 | 0.00 |
October | 0.00 | 0.00 | 0.182577E+11 | 0.897556E+10 | 28756.63 | 23-OCT-07:02 | 11028.86 | 0.00 |
November | 0.00 | 0.00 | 0.166417E+11 | 0.881153E+10 | 28715.08 | 20-NOV-08:61 | 12138.30 | 0.00 |
December | 0.00 | 0.00 | 0.154475E+11 | 0.899970E+10 | 28721.08 | 11-DEC-08:62 | 10851.86 | 0.00 |
Annual Sum or Average | 0.220402E+12 | 0.118429E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.150399E+11 | 0.881153E+10 | 28259.99 | 10344.60 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.226233E+11 | 0.113761E+11 | 28767.04 | 13136.01 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.170124E+11 | 0.106173E+11 | 32546.77 | 09-JAN-08:62 | 13750.36 | 0.00 |
February | 0.00 | 0.00 | 0.167990E+11 | 0.104962E+11 | 32206.61 | 20-FEB-09:01 | 15904.96 | 0.00 |
March | 0.00 | 0.00 | 0.199856E+11 | 0.123451E+11 | 32565.20 | 27-MAR-07:01 | 13540.73 | 0.00 |
April | 0.00 | 0.00 | 0.218841E+11 | 0.123629E+11 | 32627.95 | 24-APR-07:01 | 13491.63 | 0.00 |
May | 0.00 | 0.00 | 0.248501E+11 | 0.129401E+11 | 32599.88 | 16-MAY-07:02 | 13539.51 | 0.00 |
June | 0.00 | 0.00 | 0.251566E+11 | 0.130623E+11 | 32599.88 | 26-JUN-07:02 | 12111.18 | 0.00 |
July | 0.00 | 0.00 | 0.195711E+11 | 0.108557E+11 | 32636.76 | 05-JUL-07:01 | 13715.22 | 0.00 |
August | 0.00 | 0.00 | 0.227920E+11 | 0.112619E+11 | 32636.76 | 21-AUG-07:02 | 11714.82 | 0.00 |
September | 0.00 | 0.00 | 0.213002E+11 | 0.108852E+11 | 32673.75 | 18-SEP-07:02 | 11916.86 | 0.00 |
October | 0.00 | 0.00 | 0.199628E+11 | 0.101031E+11 | 32673.32 | 23-OCT-07:02 | 12421.70 | 0.00 |
November | 0.00 | 0.00 | 0.183076E+11 | 0.995012E+10 | 32647.07 | 05-NOV-08:62 | 13552.53 | 0.00 |
December | 0.00 | 0.00 | 0.170424E+11 | 0.101343E+11 | 32621.55 | 11-DEC-08:62 | 12379.57 | 0.00 |
Annual Sum or Average | 0.244664E+12 | 0.135014E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.167990E+11 | 0.995012E+10 | 32206.61 | 11714.82 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.251566E+11 | 0.130623E+11 | 32673.75 | 15904.96 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.176508E+10 | 0.37 | 2252.23 | 01-JAN-08:62 | 0.86 |
February | 0.168392E+10 | 0.38 | 2252.23 | 01-FEB-08:62 | 0.87 |
March | 0.190515E+10 | 0.39 | 2252.23 | 01-MAR-08:62 | 0.86 |
April | 0.197935E+10 | 0.40 | 2252.23 | 01-APR-07:01 | 0.86 |
May | 0.216242E+10 | 0.41 | 2252.23 | 01-MAY-07:01 | 0.86 |
June | 0.216340E+10 | 0.42 | 2252.23 | 01-JUN-07:02 | 0.86 |
July | 0.186786E+10 | 0.38 | 2252.23 | 01-JUL-07:02 | 0.86 |
August | 0.201305E+10 | 0.40 | 2252.23 | 01-AUG-07:02 | 0.86 |
September | 0.193496E+10 | 0.40 | 2252.23 | 01-SEP-07:02 | 0.86 |
October | 0.188907E+10 | 0.38 | 2252.23 | 01-OCT-07:01 | 0.86 |
November | 0.177325E+10 | 0.38 | 2252.23 | 01-NOV-07:02 | 0.86 |
December | 0.176877E+10 | 0.37 | 2252.23 | 01-DEC-08:62 | 0.86 |
Annual Sum or Average | 0.229063E+11 | 0.39 | |||
Minimum of Months | 0.168392E+10 | 0.37 | 2252.23 | 0.86 | |
Maximum of Months | 0.216340E+10 | 0.42 | 2252.23 | 0.87 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.847589E+09 | 0.38 | 1218.87 | 01-JAN-08:62 | 0.90 |
February | 0.812988E+09 | 0.39 | 1218.87 | 01-FEB-08:62 | 0.90 |
March | 0.927580E+09 | 0.40 | 1218.87 | 01-MAR-08:62 | 0.90 |
April | 0.976157E+09 | 0.41 | 1218.87 | 01-APR-07:01 | 0.89 |
May | 0.107995E+10 | 0.42 | 1218.87 | 01-MAY-07:01 | 0.89 |
June | 0.107872E+10 | 0.43 | 1218.87 | 01-JUN-07:02 | 0.89 |
July | 0.913164E+09 | 0.39 | 1218.87 | 01-JUL-07:02 | 0.89 |
August | 0.993866E+09 | 0.41 | 1218.87 | 01-AUG-07:02 | 0.89 |
September | 0.951625E+09 | 0.41 | 1218.87 | 01-SEP-07:02 | 0.89 |
October | 0.925817E+09 | 0.40 | 1218.87 | 01-OCT-07:01 | 0.90 |
November | 0.863091E+09 | 0.39 | 1218.87 | 01-NOV-07:02 | 0.90 |
December | 0.847344E+09 | 0.38 | 1218.87 | 01-DEC-08:62 | 0.90 |
Annual Sum or Average | 0.112179E+11 | 0.40 | |||
Minimum of Months | 0.812988E+09 | 0.38 | 1218.87 | 0.89 | |
Maximum of Months | 0.107995E+10 | 0.43 | 1218.87 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.766448E+09 | 0.31 | 1221.60 | 01-JAN-08:62 | 0.89 |
February | 0.735838E+09 | 0.32 | 1221.60 | 01-FEB-07:02 | 0.90 |
March | 0.845469E+09 | 0.33 | 1221.60 | 01-MAR-07:01 | 0.89 |
April | 0.871415E+09 | 0.34 | 1221.60 | 01-APR-06:01 | 0.89 |
May | 0.970273E+09 | 0.35 | 1221.60 | 01-MAY-06:01 | 0.88 |
June | 0.976569E+09 | 0.36 | 1221.60 | 01-JUN-06:01 | 0.89 |
July | 0.813213E+09 | 0.32 | 1221.60 | 01-JUL-06:02 | 0.89 |
August | 0.903466E+09 | 0.34 | 1221.60 | 01-AUG-06:01 | 0.89 |
September | 0.851515E+09 | 0.33 | 1221.60 | 01-SEP-06:02 | 0.89 |
October | 0.831649E+09 | 0.32 | 1221.60 | 01-OCT-07:01 | 0.89 |
November | 0.777169E+09 | 0.32 | 1221.60 | 01-NOV-06:02 | 0.89 |
December | 0.761168E+09 | 0.31 | 1221.60 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.101042E+11 | 0.33 | |||
Minimum of Months | 0.735838E+09 | 0.31 | 1221.60 | 0.88 | |
Maximum of Months | 0.976569E+09 | 0.36 | 1221.60 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.768008E+09 | 0.31 | 1225.32 | 01-JAN-08:62 | 0.89 |
February | 0.737347E+09 | 0.32 | 1225.32 | 01-FEB-07:02 | 0.90 |
March | 0.847312E+09 | 0.33 | 1225.32 | 01-MAR-07:01 | 0.89 |
April | 0.873592E+09 | 0.34 | 1225.32 | 01-APR-06:01 | 0.89 |
May | 0.973712E+09 | 0.35 | 1225.32 | 01-MAY-06:01 | 0.88 |
June | 0.979829E+09 | 0.36 | 1225.32 | 01-JUN-06:01 | 0.89 |
July | 0.815384E+09 | 0.32 | 1225.32 | 01-JUL-06:02 | 0.89 |
August | 0.905456E+09 | 0.34 | 1225.32 | 01-AUG-06:01 | 0.89 |
September | 0.853507E+09 | 0.33 | 1225.32 | 01-SEP-06:02 | 0.89 |
October | 0.833352E+09 | 0.32 | 1225.32 | 01-OCT-07:01 | 0.89 |
November | 0.778533E+09 | 0.32 | 1225.32 | 01-NOV-06:02 | 0.89 |
December | 0.762597E+09 | 0.31 | 1225.32 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.101286E+11 | 0.33 | |||
Minimum of Months | 0.737347E+09 | 0.31 | 1225.32 | 0.88 | |
Maximum of Months | 0.979829E+09 | 0.36 | 1225.32 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.760060E+09 | 0.31 | 1214.62 | 01-JAN-08:62 | 0.89 |
February | 0.729762E+09 | 0.32 | 1214.62 | 01-FEB-07:02 | 0.90 |
March | 0.838633E+09 | 0.33 | 1214.62 | 01-MAR-07:01 | 0.89 |
April | 0.864678E+09 | 0.34 | 1214.62 | 01-APR-06:01 | 0.89 |
May | 0.964155E+09 | 0.35 | 1214.62 | 01-MAY-06:01 | 0.88 |
June | 0.970099E+09 | 0.36 | 1214.62 | 01-JUN-06:01 | 0.89 |
July | 0.806842E+09 | 0.32 | 1214.62 | 01-JUL-06:02 | 0.89 |
August | 0.895631E+09 | 0.34 | 1214.62 | 01-AUG-06:01 | 0.89 |
September | 0.844449E+09 | 0.33 | 1214.62 | 01-SEP-06:02 | 0.89 |
October | 0.824368E+09 | 0.32 | 1214.62 | 01-OCT-07:01 | 0.89 |
November | 0.770122E+09 | 0.31 | 1214.62 | 01-NOV-06:02 | 0.89 |
December | 0.754568E+09 | 0.30 | 1214.62 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.100234E+11 | 0.33 | |||
Minimum of Months | 0.729762E+09 | 0.30 | 1214.62 | 0.88 | |
Maximum of Months | 0.970099E+09 | 0.36 | 1214.62 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.121834E+10 | 0.28 | 2047.16 | 01-JAN-09:02 | 0.86 |
February | 0.118157E+10 | 0.29 | 2047.16 | 01-FEB-08:62 | 0.87 |
March | 0.136223E+10 | 0.30 | 2047.16 | 01-MAR-08:62 | 0.86 |
April | 0.142207E+10 | 0.31 | 2047.16 | 01-APR-07:01 | 0.86 |
May | 0.160818E+10 | 0.32 | 2047.16 | 01-MAY-07:01 | 0.85 |
June | 0.162067E+10 | 0.33 | 2047.16 | 01-JUN-07:02 | 0.86 |
July | 0.130742E+10 | 0.29 | 2047.16 | 01-JUL-07:02 | 0.86 |
August | 0.147284E+10 | 0.31 | 2047.16 | 01-AUG-07:02 | 0.86 |
September | 0.138645E+10 | 0.30 | 2047.16 | 01-SEP-07:02 | 0.86 |
October | 0.133873E+10 | 0.29 | 2047.16 | 01-OCT-08:61 | 0.86 |
November | 0.124404E+10 | 0.29 | 2047.16 | 01-NOV-07:02 | 0.86 |
December | 0.120830E+10 | 0.28 | 2047.16 | 01-DEC-08:62 | 0.86 |
Annual Sum or Average | 0.163708E+11 | 0.30 | |||
Minimum of Months | 0.118157E+10 | 0.28 | 2047.16 | 0.85 | |
Maximum of Months | 0.162067E+10 | 0.33 | 2047.16 | 0.87 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.660069E+09 | 0.29 | 1113.41 | 01-JAN-09:02 | 0.89 |
February | 0.640184E+09 | 0.30 | 1113.41 | 01-FEB-08:62 | 0.90 |
March | 0.738002E+09 | 0.31 | 1113.41 | 01-MAR-08:62 | 0.89 |
April | 0.768017E+09 | 0.32 | 1113.41 | 01-APR-07:01 | 0.89 |
May | 0.865444E+09 | 0.33 | 1113.41 | 01-MAY-07:01 | 0.88 |
June | 0.870801E+09 | 0.34 | 1113.41 | 01-JUN-07:02 | 0.89 |
July | 0.706822E+09 | 0.30 | 1113.41 | 01-JUL-07:02 | 0.89 |
August | 0.793262E+09 | 0.32 | 1113.41 | 01-AUG-07:02 | 0.89 |
September | 0.747521E+09 | 0.31 | 1113.41 | 01-SEP-07:02 | 0.89 |
October | 0.723280E+09 | 0.30 | 1113.41 | 01-OCT-08:61 | 0.89 |
November | 0.672498E+09 | 0.30 | 1113.41 | 01-NOV-07:02 | 0.89 |
December | 0.654297E+09 | 0.29 | 1113.41 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.884020E+10 | 0.31 | |||
Minimum of Months | 0.640184E+09 | 0.29 | 1113.41 | 0.88 | |
Maximum of Months | 0.870801E+09 | 0.34 | 1113.41 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.657039E+09 | 0.29 | 1107.80 | 01-JAN-09:02 | 0.89 |
February | 0.637478E+09 | 0.30 | 1107.80 | 01-FEB-08:62 | 0.90 |
March | 0.734994E+09 | 0.31 | 1107.80 | 01-MAR-08:62 | 0.89 |
April | 0.765190E+09 | 0.32 | 1107.80 | 01-APR-07:01 | 0.89 |
May | 0.862588E+09 | 0.33 | 1107.80 | 01-MAY-07:01 | 0.88 |
June | 0.867913E+09 | 0.34 | 1107.80 | 01-JUN-07:02 | 0.89 |
July | 0.703894E+09 | 0.30 | 1107.80 | 01-JUL-07:02 | 0.89 |
August | 0.790280E+09 | 0.32 | 1107.80 | 01-AUG-07:02 | 0.89 |
September | 0.744697E+09 | 0.31 | 1107.80 | 01-SEP-07:02 | 0.89 |
October | 0.720217E+09 | 0.30 | 1107.80 | 01-OCT-08:61 | 0.89 |
November | 0.669467E+09 | 0.30 | 1107.80 | 01-NOV-07:02 | 0.89 |
December | 0.651228E+09 | 0.29 | 1107.80 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.880499E+10 | 0.31 | |||
Minimum of Months | 0.637478E+09 | 0.29 | 1107.80 | 0.88 | |
Maximum of Months | 0.867913E+09 | 0.34 | 1107.80 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.657998E+09 | 0.29 | 1110.98 | 01-JAN-09:02 | 0.89 |
February | 0.638819E+09 | 0.30 | 1110.98 | 01-FEB-08:62 | 0.90 |
March | 0.737083E+09 | 0.31 | 1110.98 | 01-MAR-08:62 | 0.89 |
April | 0.767949E+09 | 0.32 | 1110.98 | 01-APR-07:01 | 0.89 |
May | 0.865727E+09 | 0.33 | 1110.98 | 01-MAY-07:01 | 0.88 |
June | 0.871438E+09 | 0.34 | 1110.98 | 01-JUN-07:02 | 0.89 |
July | 0.706037E+09 | 0.30 | 1110.98 | 01-JUL-07:02 | 0.89 |
August | 0.792703E+09 | 0.32 | 1110.98 | 01-AUG-07:02 | 0.89 |
September | 0.747061E+09 | 0.31 | 1110.98 | 01-SEP-07:02 | 0.89 |
October | 0.721357E+09 | 0.30 | 1110.98 | 01-OCT-08:61 | 0.89 |
November | 0.670338E+09 | 0.30 | 1110.98 | 01-NOV-07:02 | 0.89 |
December | 0.651998E+09 | 0.28 | 1110.98 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.882851E+10 | 0.31 | |||
Minimum of Months | 0.638819E+09 | 0.28 | 1110.98 | 0.88 | |
Maximum of Months | 0.871438E+09 | 0.34 | 1110.98 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.732794E+09 | 0.28 | 1261.86 | 01-JAN-09:02 | 0.89 |
February | 0.711705E+09 | 0.30 | 1261.86 | 01-FEB-08:62 | 0.90 |
March | 0.828163E+09 | 0.31 | 1261.86 | 01-MAR-08:62 | 0.89 |
April | 0.864261E+09 | 0.32 | 1261.86 | 01-APR-07:01 | 0.89 |
May | 0.966825E+09 | 0.33 | 1261.86 | 01-MAY-07:01 | 0.88 |
June | 0.976458E+09 | 0.34 | 1261.86 | 01-JUN-07:02 | 0.89 |
July | 0.792221E+09 | 0.30 | 1261.86 | 01-JUL-07:02 | 0.89 |
August | 0.887345E+09 | 0.32 | 1261.86 | 01-AUG-07:02 | 0.89 |
September | 0.837443E+09 | 0.31 | 1261.86 | 01-SEP-07:02 | 0.89 |
October | 0.800261E+09 | 0.30 | 1261.86 | 01-OCT-08:61 | 0.89 |
November | 0.744259E+09 | 0.29 | 1261.86 | 01-NOV-07:02 | 0.89 |
December | 0.726098E+09 | 0.28 | 1261.86 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.986783E+10 | 0.31 | |||
Minimum of Months | 0.711705E+09 | 0.28 | 1261.86 | 0.88 | |
Maximum of Months | 0.976458E+09 | 0.34 | 1261.86 | 0.90 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.97 | 0.00 |
February | 1.03 | 0.00 |
March | 0.83 | 0.00 |
April | 0.19 | 0.00 |
May | 0.36 | 0.00 |
June | 0.50 | 0.00 |
July | 1.17 | 0.00 |
August | 0.83 | 0.00 |
September | 0.81 | 0.00 |
October | 1.14 | 0.00 |
November | 1.00 | 0.00 |
December | 0.50 | 0.00 |
Annual Sum or Average | 9.33 | 0.00 |
Minimum of Months | 0.19 | 0.00 |
Maximum of Months | 1.17 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.56 | 0.08 |
February | 1.11 | 0.00 |
March | 0.83 | 0.00 |
April | 0.28 | 0.00 |
May | 0.28 | 0.00 |
June | 0.42 | 0.00 |
July | 1.25 | 0.00 |
August | 0.83 | 0.00 |
September | 0.97 | 0.00 |
October | 1.39 | 0.00 |
November | 1.25 | 0.00 |
December | 0.75 | 0.00 |
Annual Sum or Average | 10.92 | 0.01 |
Minimum of Months | 0.28 | 0.00 |
Maximum of Months | 1.56 | 0.08 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.42 | 0.75 |
February | 2.59 | 0.75 |
March | 2.95 | 0.75 |
April | 3.40 | 0.75 |
May | 3.59 | 0.74 |
June | 3.53 | 0.75 |
July | 2.67 | 0.75 |
August | 2.89 | 0.75 |
September | 2.92 | 0.75 |
October | 2.49 | 0.75 |
November | 2.04 | 0.75 |
December | 2.39 | 0.75 |
Annual Sum or Average | 33.88 | 0.75 |
Minimum of Months | 2.04 | 0.74 |
Maximum of Months | 3.59 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.42 | 0.75 |
February | 2.59 | 0.75 |
March | 2.95 | 0.75 |
April | 3.40 | 0.75 |
May | 3.59 | 0.74 |
June | 3.53 | 0.75 |
July | 2.67 | 0.75 |
August | 2.89 | 0.75 |
September | 2.92 | 0.75 |
October | 2.49 | 0.75 |
November | 2.04 | 0.75 |
December | 2.39 | 0.75 |
Annual Sum or Average | 33.88 | 0.75 |
Minimum of Months | 2.04 | 0.74 |
Maximum of Months | 3.59 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.19 | 0.75 |
February | 2.48 | 0.75 |
March | 2.89 | 0.75 |
April | 3.40 | 0.75 |
May | 3.55 | 0.75 |
June | 3.48 | 0.75 |
July | 2.67 | 0.75 |
August | 2.78 | 0.75 |
September | 2.87 | 0.75 |
October | 2.41 | 0.75 |
November | 1.79 | 0.75 |
December | 2.22 | 0.75 |
Annual Sum or Average | 32.73 | 0.75 |
Minimum of Months | 1.79 | 0.75 |
Maximum of Months | 3.55 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.32 | 1.77 |
February | 1.68 | 2.53 |
March | 1.23 | 2.70 |
April | 1.25 | 3.15 |
May | 1.41 | 2.63 |
June | 1.10 | 2.14 |
July | 1.12 | 3.14 |
August | 1.22 | 2.46 |
September | 1.02 | 3.30 |
October | 1.24 | 2.71 |
November | 1.29 | 1.88 |
December | 0.53 | 2.60 |
Annual Sum or Average | 14.39 | 2.56 |
Minimum of Months | 0.53 | 1.77 |
Maximum of Months | 1.68 | 3.30 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.96 | 0.88 |
February | 1.59 | 1.25 |
March | 1.17 | 1.42 |
April | 1.11 | 1.57 |
May | 1.30 | 1.37 |
June | 1.01 | 1.16 |
July | 1.08 | 1.56 |
August | 1.10 | 1.27 |
September | 0.98 | 1.65 |
October | 1.24 | 1.36 |
November | 1.04 | 1.03 |
December | 0.58 | 1.34 |
Annual Sum or Average | 13.17 | 1.32 |
Minimum of Months | 0.58 | 0.88 |
Maximum of Months | 1.59 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.90 | 0.94 |
February | 1.54 | 1.29 |
March | 1.12 | 1.49 |
April | 1.11 | 1.57 |
May | 1.30 | 1.37 |
June | 1.01 | 1.16 |
July | 1.08 | 1.56 |
August | 1.05 | 1.34 |
September | 0.98 | 1.65 |
October | 1.19 | 1.42 |
November | 1.04 | 1.03 |
December | 0.58 | 1.34 |
Annual Sum or Average | 12.89 | 1.35 |
Minimum of Months | 0.58 | 0.94 |
Maximum of Months | 1.54 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.90 | 0.94 |
February | 1.54 | 1.29 |
March | 1.12 | 1.49 |
April | 1.11 | 1.57 |
May | 1.23 | 1.46 |
June | 0.95 | 1.24 |
July | 1.08 | 1.56 |
August | 1.10 | 1.27 |
September | 0.98 | 1.65 |
October | 1.13 | 1.49 |
November | 1.04 | 1.03 |
December | 0.58 | 1.34 |
Annual Sum or Average | 12.75 | 1.37 |
Minimum of Months | 0.58 | 0.94 |
Maximum of Months | 1.54 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.82 | 0.64 |
February | 2.18 | 0.91 |
March | 1.56 | 1.06 |
April | 1.33 | 1.48 |
May | 1.52 | 1.17 |
June | 1.32 | 0.96 |
July | 1.20 | 1.46 |
August | 1.85 | 0.76 |
September | 1.16 | 1.45 |
October | 1.72 | 0.98 |
November | 1.71 | 0.71 |
December | 0.81 | 1.08 |
Annual Sum or Average | 18.17 | 1.01 |
Minimum of Months | 0.81 | 0.64 |
Maximum of Months | 2.18 | 1.48 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.120474E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.117631E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.137244E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.148267E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.162963E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.161984E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.133756E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.146765E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.140854E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.134411E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.124942E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.121013E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.165031E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.117631E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.162963E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.593195E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.576380E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.670108E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.721524E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.796891E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.791747E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.654040E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.719182E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.688449E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.661383E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.614519E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.595910E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.808333E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.576380E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.796891E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.487737E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.477471E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.564279E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.598898E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.671229E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.673247E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.535462E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.608926E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.571964E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.548634E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.509092E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.487202E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.673414E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.477471E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.673247E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.488901E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.478655E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.565689E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.600644E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.673654E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.675524E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.537275E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.610245E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.573403E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.549887E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.509929E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.488013E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.675182E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.478655E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.675524E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.482517E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.472751E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.558859E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.593847E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.666675E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.668573E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.530768E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.602798E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.566551E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.542926E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.503350E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.481473E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.667109E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.472751E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.668573E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.850868E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.836719E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.990622E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.105636E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.119306E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.120089E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.934541E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.107169E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.100379E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.956159E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.886237E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.844185E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.118251E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.836719E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.120089E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.438122E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.431124E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.510246E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.543838E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.613379E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.616839E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.480668E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.550391E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.515985E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.491591E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.455646E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.434384E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.608221E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.431124E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.616839E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.435879E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.429160E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.507998E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.541702E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.611136E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.614580E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.478552E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.548111E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.513874E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.489284E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.453394E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.432117E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.605579E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.429160E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.614580E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.436037E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.430027E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.509231E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.543499E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.613015E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.616804E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.479838E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.549267E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.515220E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.489405E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.453437E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.432020E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.606780E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.430027E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.616804E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.486005E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.482285E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.574796E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.613485E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.685210E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.692544E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.539524E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.614750E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.577756E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.540764E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.503026E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.480249E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.679039E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.480249E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.692544E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.176508E+10 | 0.418293E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.168392E+10 | 0.406299E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.190515E+10 | 0.475407E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.197935E+10 | 0.528351E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.216242E+10 | 0.591758E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.216340E+10 | 0.588642E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.186786E+10 | 0.480781E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.201305E+10 | 0.541397E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.193496E+10 | 0.516752E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.188907E+10 | 0.492827E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.177325E+10 | 0.451494E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.176877E+10 | 0.427065E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.229063E+11 | 0.591907E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.168392E+10 | 0.406299E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.216340E+10 | 0.591758E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.847589E+09 | 0.206840E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.812988E+09 | 0.199529E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.927580E+09 | 0.231870E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.976157E+09 | 0.255848E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.107995E+10 | 0.287956E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.107872E+10 | 0.286676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.913164E+09 | 0.234737E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.993866E+09 | 0.264937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.951625E+09 | 0.252000E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.925817E+09 | 0.242568E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.863091E+09 | 0.222379E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.847344E+09 | 0.211144E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.112179E+11 | 0.289648E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.812988E+09 | 0.199529E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.107995E+10 | 0.287956E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.766448E+09 | 0.170212E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.735838E+09 | 0.165565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.845469E+09 | 0.195586E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.871415E+09 | 0.213451E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.970273E+09 | 0.243975E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.976569E+09 | 0.244894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.813213E+09 | 0.193758E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.903466E+09 | 0.225983E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.851515E+09 | 0.211080E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.831649E+09 | 0.202841E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.777169E+09 | 0.185167E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.761168E+09 | 0.172753E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101042E+11 | 0.242526E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.735838E+09 | 0.165565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.976569E+09 | 0.244894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.768008E+09 | 0.170612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.737347E+09 | 0.165982E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.847312E+09 | 0.196072E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.873592E+09 | 0.214073E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.973712E+09 | 0.244810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.979829E+09 | 0.245664E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.815384E+09 | 0.194442E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.905456E+09 | 0.226415E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.853507E+09 | 0.211581E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.833352E+09 | 0.203286E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.778533E+09 | 0.185429E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.762597E+09 | 0.172996E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101286E+11 | 0.243136E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.737347E+09 | 0.165982E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.979829E+09 | 0.245664E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.760060E+09 | 0.168268E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.729762E+09 | 0.163862E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.838633E+09 | 0.193637E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.864678E+09 | 0.211676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.964155E+09 | 0.242397E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.970099E+09 | 0.243282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.806842E+09 | 0.192052E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.895631E+09 | 0.223685E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.844449E+09 | 0.209073E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.824368E+09 | 0.200678E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.770122E+09 | 0.182971E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.754568E+09 | 0.170547E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.100234E+11 | 0.240213E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.729762E+09 | 0.163862E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.970099E+09 | 0.243282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.121834E+10 | 0.297943E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118157E+10 | 0.290848E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136223E+10 | 0.344022E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.142207E+10 | 0.377056E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.160818E+10 | 0.433677E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.162067E+10 | 0.437039E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.130742E+10 | 0.339109E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.147284E+10 | 0.398548E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.138645E+10 | 0.371016E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133873E+10 | 0.354528E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.124404E+10 | 0.323364E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.120830E+10 | 0.300266E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.163708E+11 | 0.426742E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.118157E+10 | 0.290848E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.162067E+10 | 0.437039E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.660069E+09 | 0.154355E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.640184E+09 | 0.150804E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.738002E+09 | 0.178295E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.768017E+09 | 0.195466E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.865444E+09 | 0.224705E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.870801E+09 | 0.226287E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.706822E+09 | 0.175525E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.793262E+09 | 0.206124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.747521E+09 | 0.192070E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.723280E+09 | 0.183458E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.672498E+09 | 0.167297E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.654297E+09 | 0.155426E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.884020E+10 | 0.220981E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.640184E+09 | 0.150804E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.870801E+09 | 0.226287E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.657039E+09 | 0.153576E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.637478E+09 | 0.150139E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.734994E+09 | 0.177546E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.765190E+09 | 0.194755E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.862588E+09 | 0.223951E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.867913E+09 | 0.225530E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.703894E+09 | 0.174792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.790280E+09 | 0.205330E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.744697E+09 | 0.191338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.720217E+09 | 0.182646E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.669467E+09 | 0.166499E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651228E+09 | 0.154627E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.880499E+10 | 0.220073E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.637478E+09 | 0.150139E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.867913E+09 | 0.225530E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.657998E+09 | 0.153543E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.638819E+09 | 0.150399E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.737083E+09 | 0.177915E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.767949E+09 | 0.195329E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.865727E+09 | 0.224517E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.871438E+09 | 0.226233E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.706037E+09 | 0.175216E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.792703E+09 | 0.205649E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.747061E+09 | 0.191752E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.721357E+09 | 0.182577E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.670338E+09 | 0.166417E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651998E+09 | 0.154475E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.882851E+10 | 0.220402E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.638819E+09 | 0.150399E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.871438E+09 | 0.226233E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.732794E+09 | 0.170124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.711705E+09 | 0.167990E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.828163E+09 | 0.199856E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.864261E+09 | 0.218841E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.966825E+09 | 0.248501E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.976458E+09 | 0.251566E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.792221E+09 | 0.195711E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.887345E+09 | 0.227920E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.837443E+09 | 0.213002E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.800261E+09 | 0.199628E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.744259E+09 | 0.183076E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.726098E+09 | 0.170424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.986783E+10 | 0.244664E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.711705E+09 | 0.167990E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.976458E+09 | 0.251566E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.176508E+10 | 0.00 | 0.00 | 0.00 | 0.102824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.168392E+10 | 0.00 | 0.00 | 0.00 | 0.100792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.190515E+10 | 0.00 | 0.00 | 0.00 | 0.118192E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.197935E+10 | 0.00 | 0.00 | 0.00 | 0.128474E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.216242E+10 | 0.00 | 0.00 | 0.00 | 0.141338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.216340E+10 | 0.00 | 0.00 | 0.00 | 0.140350E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.186786E+10 | 0.00 | 0.00 | 0.00 | 0.115078E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.201305E+10 | 0.00 | 0.00 | 0.00 | 0.126635E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.193496E+10 | 0.00 | 0.00 | 0.00 | 0.121504E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.188907E+10 | 0.00 | 0.00 | 0.00 | 0.115521E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.177325E+10 | 0.00 | 0.00 | 0.00 | 0.107209E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.176877E+10 | 0.00 | 0.00 | 0.00 | 0.103325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.229063E+11 | 0.00 | 0.00 | 0.00 | 0.142124E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.168392E+10 | 0.00 | 0.00 | 0.00 | 0.100792E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.216340E+10 | 0.00 | 0.00 | 0.00 | 0.141338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.847589E+09 | 0.00 | 0.00 | 0.00 | 0.508436E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.812988E+09 | 0.00 | 0.00 | 0.00 | 0.495081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.927580E+09 | 0.00 | 0.00 | 0.00 | 0.577350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.976157E+09 | 0.00 | 0.00 | 0.00 | 0.623908E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.688896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.107872E+10 | 0.00 | 0.00 | 0.00 | 0.683875E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.913164E+09 | 0.00 | 0.00 | 0.00 | 0.562724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.993866E+09 | 0.00 | 0.00 | 0.00 | 0.619795E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.951625E+09 | 0.00 | 0.00 | 0.00 | 0.593286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.925817E+09 | 0.00 | 0.00 | 0.00 | 0.568802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.863091E+09 | 0.00 | 0.00 | 0.00 | 0.528209E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.847344E+09 | 0.00 | 0.00 | 0.00 | 0.511175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.112179E+11 | 0.00 | 0.00 | 0.00 | 0.696154E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.812988E+09 | 0.00 | 0.00 | 0.00 | 0.495081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.688896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.766448E+09 | 0.00 | 0.00 | 0.00 | 0.411092E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.735838E+09 | 0.00 | 0.00 | 0.00 | 0.403887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.845469E+09 | 0.00 | 0.00 | 0.00 | 0.479732E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.871415E+09 | 0.00 | 0.00 | 0.00 | 0.511756E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.970273E+09 | 0.00 | 0.00 | 0.00 | 0.574202E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.976569E+09 | 0.00 | 0.00 | 0.00 | 0.575590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.813213E+09 | 0.00 | 0.00 | 0.00 | 0.454141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.903466E+09 | 0.00 | 0.00 | 0.00 | 0.518580E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.851515E+09 | 0.00 | 0.00 | 0.00 | 0.486812E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.831649E+09 | 0.00 | 0.00 | 0.00 | 0.465469E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.777169E+09 | 0.00 | 0.00 | 0.00 | 0.431376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.761168E+09 | 0.00 | 0.00 | 0.00 | 0.411085E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101042E+11 | 0.00 | 0.00 | 0.00 | 0.572372E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.735838E+09 | 0.00 | 0.00 | 0.00 | 0.403887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.976569E+09 | 0.00 | 0.00 | 0.00 | 0.575590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.768008E+09 | 0.00 | 0.00 | 0.00 | 0.412100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.737347E+09 | 0.00 | 0.00 | 0.00 | 0.404920E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.847312E+09 | 0.00 | 0.00 | 0.00 | 0.480957E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.873592E+09 | 0.00 | 0.00 | 0.00 | 0.513284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.973712E+09 | 0.00 | 0.00 | 0.00 | 0.576283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.979829E+09 | 0.00 | 0.00 | 0.00 | 0.577541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.815384E+09 | 0.00 | 0.00 | 0.00 | 0.455737E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.905456E+09 | 0.00 | 0.00 | 0.00 | 0.519700E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.853507E+09 | 0.00 | 0.00 | 0.00 | 0.488053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.833352E+09 | 0.00 | 0.00 | 0.00 | 0.466552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.778533E+09 | 0.00 | 0.00 | 0.00 | 0.432075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.762597E+09 | 0.00 | 0.00 | 0.00 | 0.411754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101286E+11 | 0.00 | 0.00 | 0.00 | 0.573896E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.737347E+09 | 0.00 | 0.00 | 0.00 | 0.404920E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.979829E+09 | 0.00 | 0.00 | 0.00 | 0.577541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.760060E+09 | 0.00 | 0.00 | 0.00 | 0.406511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.729762E+09 | 0.00 | 0.00 | 0.00 | 0.399775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.838633E+09 | 0.00 | 0.00 | 0.00 | 0.474995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.864678E+09 | 0.00 | 0.00 | 0.00 | 0.507379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.964155E+09 | 0.00 | 0.00 | 0.00 | 0.570260E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.970099E+09 | 0.00 | 0.00 | 0.00 | 0.571563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.806842E+09 | 0.00 | 0.00 | 0.00 | 0.450084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.895631E+09 | 0.00 | 0.00 | 0.00 | 0.513234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.844449E+09 | 0.00 | 0.00 | 0.00 | 0.482106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.824368E+09 | 0.00 | 0.00 | 0.00 | 0.460490E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.770122E+09 | 0.00 | 0.00 | 0.00 | 0.426338E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.754568E+09 | 0.00 | 0.00 | 0.00 | 0.406016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.100234E+11 | 0.00 | 0.00 | 0.00 | 0.566875E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.729762E+09 | 0.00 | 0.00 | 0.00 | 0.399775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.970099E+09 | 0.00 | 0.00 | 0.00 | 0.571563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.121834E+10 | 0.00 | 0.00 | 0.00 | 0.729034E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118157E+10 | 0.00 | 0.00 | 0.00 | 0.718562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136223E+10 | 0.00 | 0.00 | 0.00 | 0.854399E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.142207E+10 | 0.00 | 0.00 | 0.00 | 0.914156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.160818E+10 | 0.00 | 0.00 | 0.00 | 0.103224E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.162067E+10 | 0.00 | 0.00 | 0.00 | 0.103882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.130742E+10 | 0.00 | 0.00 | 0.00 | 0.803799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.147284E+10 | 0.00 | 0.00 | 0.00 | 0.924403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.138645E+10 | 0.00 | 0.00 | 0.00 | 0.865143E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133873E+10 | 0.00 | 0.00 | 0.00 | 0.822286E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.124404E+10 | 0.00 | 0.00 | 0.00 | 0.761834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.120830E+10 | 0.00 | 0.00 | 0.00 | 0.723355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.163708E+11 | 0.00 | 0.00 | 0.00 | 0.101880E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.118157E+10 | 0.00 | 0.00 | 0.00 | 0.718562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.162067E+10 | 0.00 | 0.00 | 0.00 | 0.103882E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.660069E+09 | 0.00 | 0.00 | 0.00 | 0.372115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.640184E+09 | 0.00 | 0.00 | 0.00 | 0.367106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.738002E+09 | 0.00 | 0.00 | 0.00 | 0.436446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.768017E+09 | 0.00 | 0.00 | 0.00 | 0.467036E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.865444E+09 | 0.00 | 0.00 | 0.00 | 0.526835E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.870801E+09 | 0.00 | 0.00 | 0.00 | 0.529759E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.706822E+09 | 0.00 | 0.00 | 0.00 | 0.409986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.793262E+09 | 0.00 | 0.00 | 0.00 | 0.471065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.747521E+09 | 0.00 | 0.00 | 0.00 | 0.441233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.723280E+09 | 0.00 | 0.00 | 0.00 | 0.419263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.672498E+09 | 0.00 | 0.00 | 0.00 | 0.388396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.654297E+09 | 0.00 | 0.00 | 0.00 | 0.368954E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.884020E+10 | 0.00 | 0.00 | 0.00 | 0.519819E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.640184E+09 | 0.00 | 0.00 | 0.00 | 0.367106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.870801E+09 | 0.00 | 0.00 | 0.00 | 0.529759E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.657039E+09 | 0.00 | 0.00 | 0.00 | 0.370175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.637478E+09 | 0.00 | 0.00 | 0.00 | 0.365412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.734994E+09 | 0.00 | 0.00 | 0.00 | 0.434499E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.765190E+09 | 0.00 | 0.00 | 0.00 | 0.465183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.862588E+09 | 0.00 | 0.00 | 0.00 | 0.524877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.867913E+09 | 0.00 | 0.00 | 0.00 | 0.527789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.703894E+09 | 0.00 | 0.00 | 0.00 | 0.408162E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.790280E+09 | 0.00 | 0.00 | 0.00 | 0.469083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.744697E+09 | 0.00 | 0.00 | 0.00 | 0.439405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.720217E+09 | 0.00 | 0.00 | 0.00 | 0.417263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.669467E+09 | 0.00 | 0.00 | 0.00 | 0.386447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651228E+09 | 0.00 | 0.00 | 0.00 | 0.366995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.880499E+10 | 0.00 | 0.00 | 0.00 | 0.517529E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.637478E+09 | 0.00 | 0.00 | 0.00 | 0.365412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.867913E+09 | 0.00 | 0.00 | 0.00 | 0.527789E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.657998E+09 | 0.00 | 0.00 | 0.00 | 0.370237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.638819E+09 | 0.00 | 0.00 | 0.00 | 0.366145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.737083E+09 | 0.00 | 0.00 | 0.00 | 0.435523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.767949E+09 | 0.00 | 0.00 | 0.00 | 0.466704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.865727E+09 | 0.00 | 0.00 | 0.00 | 0.526442E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.871438E+09 | 0.00 | 0.00 | 0.00 | 0.529661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.706037E+09 | 0.00 | 0.00 | 0.00 | 0.409234E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.792703E+09 | 0.00 | 0.00 | 0.00 | 0.469996E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.747061E+09 | 0.00 | 0.00 | 0.00 | 0.440514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.721357E+09 | 0.00 | 0.00 | 0.00 | 0.417269E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.670338E+09 | 0.00 | 0.00 | 0.00 | 0.386403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651998E+09 | 0.00 | 0.00 | 0.00 | 0.366820E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.882851E+10 | 0.00 | 0.00 | 0.00 | 0.518495E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.638819E+09 | 0.00 | 0.00 | 0.00 | 0.366145E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.871438E+09 | 0.00 | 0.00 | 0.00 | 0.529661E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.732794E+09 | 0.00 | 0.00 | 0.00 | 0.412726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.711705E+09 | 0.00 | 0.00 | 0.00 | 0.411115E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.828163E+09 | 0.00 | 0.00 | 0.00 | 0.491980E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.864261E+09 | 0.00 | 0.00 | 0.00 | 0.527059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.966825E+09 | 0.00 | 0.00 | 0.00 | 0.588527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.976458E+09 | 0.00 | 0.00 | 0.00 | 0.594898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.792221E+09 | 0.00 | 0.00 | 0.00 | 0.460302E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.887345E+09 | 0.00 | 0.00 | 0.00 | 0.526016E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.837443E+09 | 0.00 | 0.00 | 0.00 | 0.494012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.800261E+09 | 0.00 | 0.00 | 0.00 | 0.460738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.744259E+09 | 0.00 | 0.00 | 0.00 | 0.428600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.726098E+09 | 0.00 | 0.00 | 0.00 | 0.407640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.986783E+10 | 0.00 | 0.00 | 0.00 | 0.580361E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.711705E+09 | 0.00 | 0.00 | 0.00 | 0.407640E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.976458E+09 | 0.00 | 0.00 | 0.00 | 0.594898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.150539E+11 | 0.00 | 154839.31 | 0.131289E+09 | 0.00 | 2273837.25 | 0.00 | 0.57 |
February | 0.00 | 0.151409E+11 | 0.00 | 50453.86 | 0.131308E+09 | 0.00 | 1168614.50 | 0.00 | 0.57 |
March | 0.00 | 0.182232E+11 | 0.00 | 0.00 | 0.113760E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
April | 0.00 | 0.224539E+11 | 0.00 | 0.00 | 0.132847E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
May | 0.00 | 0.264251E+11 | 0.00 | 0.00 | 0.102605E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
June | 0.00 | 0.261111E+11 | 0.00 | 0.00 | 0.106822E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
July | 0.00 | 0.193306E+11 | 0.00 | 0.00 | 0.162175E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
August | 0.00 | 0.237993E+11 | 0.00 | 0.00 | 0.135531E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
September | 0.00 | 0.223727E+11 | 0.00 | 0.00 | 0.155137E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
October | 0.00 | 0.209235E+11 | 0.00 | 0.00 | 0.164633E+09 | 0.00 | 0.00 | 0.00 | 0.58 |
November | 0.00 | 0.182456E+11 | 0.00 | 0.00 | 0.122690E+09 | 0.00 | 0.00 | 0.00 | 0.57 |
December | 0.00 | 0.159719E+11 | 0.00 | 4822.20 | 0.135837E+09 | 0.00 | 90807.30 | 0.00 | 0.58 |
Annual Sum or Average | 0.00 | 0.244052E+12 | 0.00 | 210115.37 | 0.159463E+10 | 0.00 | 3533259.05 | 0.00 | 0.58 |
Minimum of Months | 0.00 | 0.150539E+11 | 0.00 | 0.00 | 0.102605E+09 | 0.00 | 0.00 | 0.00 | 0.57 |
Maximum of Months | 0.00 | 0.264251E+11 | 0.00 | 154839.31 | 0.164633E+09 | 0.00 | 2273837.25 | 0.00 | 0.58 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.662748E+10 | 0.00 | 0.00 | 99893984.91 | 0.00 | 0.00 | 0.00 | 0.48 |
February | 0.00 | 0.666119E+10 | 0.00 | 0.00 | 87415692.94 | 0.00 | 0.00 | 0.00 | 0.48 |
March | 0.00 | 0.803771E+10 | 0.00 | 0.00 | 89187596.71 | 0.00 | 0.00 | 0.00 | 0.49 |
April | 0.00 | 0.986104E+10 | 0.00 | 0.00 | 85806139.99 | 0.00 | 0.00 | 0.00 | 0.50 |
May | 0.00 | 0.117273E+11 | 0.00 | 0.00 | 89459129.40 | 0.00 | 0.00 | 0.00 | 0.50 |
June | 0.00 | 0.116690E+11 | 0.00 | 0.00 | 82631876.77 | 0.00 | 0.00 | 0.00 | 0.50 |
July | 0.00 | 0.846476E+10 | 0.00 | 0.00 | 0.111080E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
August | 0.00 | 0.106006E+11 | 0.00 | 0.00 | 0.113900E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
September | 0.00 | 0.987088E+10 | 0.00 | 0.00 | 0.109430E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
October | 0.00 | 0.925091E+10 | 0.00 | 0.00 | 0.125072E+09 | 0.00 | 0.00 | 0.00 | 0.49 |
November | 0.00 | 0.806222E+10 | 0.00 | 0.00 | 97273953.59 | 0.00 | 0.00 | 0.00 | 0.49 |
December | 0.00 | 0.704480E+10 | 0.00 | 0.00 | 99659692.33 | 0.00 | 0.00 | 0.00 | 0.48 |
Annual Sum or Average | 0.00 | 0.107878E+12 | 0.00 | 0.00 | 0.119081E+10 | 0.00 | 0.00 | 0.00 | 0.49 |
Minimum of Months | 0.00 | 0.662748E+10 | 0.00 | 0.00 | 82631876.77 | 0.00 | 0.00 | 0.00 | 0.48 |
Maximum of Months | 0.00 | 0.117273E+11 | 0.00 | 0.00 | 0.125072E+09 | 0.00 | 0.00 | 0.00 | 0.50 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 2917369.69 | 0.546649E+10 | 0.00 | 347967.48 | 0.353535E+09 | 0.00 | 7319792.41 | 0.00 | 0.46 |
February | 967141.79 | 0.551119E+10 | 0.00 | 314121.28 | 0.357415E+09 | 0.00 | 880272.78 | 0.00 | 0.46 |
March | 0.00 | 0.681414E+10 | 0.00 | 38241.80 | 0.425504E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
April | 0.00 | 0.806546E+10 | 0.00 | 0.00 | 0.549084E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
May | 0.00 | 0.969985E+10 | 0.00 | 0.00 | 0.599853E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
June | 0.00 | 0.977289E+10 | 0.00 | 17140.90 | 0.603037E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
July | 0.00 | 0.692807E+10 | 0.00 | 0.00 | 0.451211E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
August | 0.00 | 0.896992E+10 | 0.00 | 14735.20 | 0.540936E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
September | 0.00 | 0.815210E+10 | 0.00 | 21421.19 | 0.519929E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
October | 0.00 | 0.768117E+10 | 0.00 | 73480.41 | 0.482971E+09 | 0.00 | 1840.66 | 0.00 | 0.46 |
November | 375545.58 | 0.664558E+10 | 0.00 | 285407.02 | 0.422975E+09 | 0.00 | 953550.63 | 0.00 | 0.46 |
December | 21578.17 | 0.573170E+10 | 0.00 | 445350.72 | 0.365183E+09 | 0.00 | 403126.06 | 0.00 | 0.46 |
Annual Sum or Average | 4281635.24 | 0.894385E+11 | 0.00 | 1557866.00 | 0.567163E+10 | 0.00 | 9558582.53 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.546649E+10 | 0.00 | 0.00 | 0.353535E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
Maximum of Months | 2917369.69 | 0.977289E+10 | 0.00 | 445350.72 | 0.603037E+09 | 0.00 | 7319792.41 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 2876909.36 | 0.547434E+10 | 0.00 | 351719.15 | 0.353456E+09 | 0.00 | 7150144.44 | 0.00 | 0.46 |
February | 940548.37 | 0.552087E+10 | 0.00 | 326471.19 | 0.355553E+09 | 0.00 | 869001.93 | 0.00 | 0.46 |
March | 0.00 | 0.682275E+10 | 0.00 | 42349.02 | 0.426312E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
April | 0.00 | 0.807765E+10 | 0.00 | 0.00 | 0.549827E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
May | 0.00 | 0.971681E+10 | 0.00 | 0.00 | 0.600149E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
June | 0.00 | 0.978812E+10 | 0.00 | 18859.70 | 0.603763E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
July | 0.00 | 0.694540E+10 | 0.00 | 0.00 | 0.448932E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
August | 0.00 | 0.897973E+10 | 0.00 | 16075.01 | 0.540605E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
September | 0.00 | 0.816332E+10 | 0.00 | 22347.84 | 0.519782E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
October | 0.00 | 0.769134E+10 | 0.00 | 77397.09 | 0.482995E+09 | 0.00 | 1842.88 | 0.00 | 0.46 |
November | 356385.93 | 0.665106E+10 | 0.00 | 295694.29 | 0.422782E+09 | 0.00 | 946637.59 | 0.00 | 0.46 |
December | 22268.85 | 0.573706E+10 | 0.00 | 457715.16 | 0.364734E+09 | 0.00 | 406113.86 | 0.00 | 0.46 |
Annual Sum or Average | 4196112.51 | 0.895684E+11 | 0.00 | 1608628.45 | 0.566889E+10 | 0.00 | 9373740.70 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.547434E+10 | 0.00 | 0.00 | 0.353456E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
Maximum of Months | 2876909.36 | 0.978812E+10 | 0.00 | 457715.16 | 0.603763E+09 | 0.00 | 7150144.44 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 3071112.35 | 0.543267E+10 | 0.00 | 335552.07 | 0.353367E+09 | 0.00 | 7888398.40 | 0.00 | 0.46 |
February | 1099603.10 | 0.548386E+10 | 0.00 | 303310.01 | 0.354901E+09 | 0.00 | 935006.97 | 0.00 | 0.46 |
March | 0.00 | 0.677918E+10 | 0.00 | 39349.72 | 0.425970E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
April | 0.00 | 0.803322E+10 | 0.00 | 0.00 | 0.548308E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
May | 0.00 | 0.967019E+10 | 0.00 | 0.00 | 0.598530E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
June | 0.00 | 0.974363E+10 | 0.00 | 17454.75 | 0.601346E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
July | 0.00 | 0.689716E+10 | 0.00 | 0.00 | 0.448467E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
August | 0.00 | 0.892252E+10 | 0.00 | 14058.06 | 0.536987E+09 | 0.00 | 0.00 | 0.00 | 0.47 |
September | 0.00 | 0.811164E+10 | 0.00 | 20206.48 | 0.516680E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
October | 0.00 | 0.763474E+10 | 0.00 | 70537.80 | 0.480844E+09 | 0.00 | 2010.76 | 0.00 | 0.46 |
November | 427662.42 | 0.659747E+10 | 0.00 | 280702.33 | 0.424651E+09 | 0.00 | 968136.98 | 0.00 | 0.46 |
December | 24128.67 | 0.569065E+10 | 0.00 | 428906.19 | 0.363002E+09 | 0.00 | 412343.44 | 0.00 | 0.46 |
Annual Sum or Average | 4622506.52 | 0.889969E+11 | 0.00 | 1510077.40 | 0.565305E+10 | 0.00 | 10205896.54 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.543267E+10 | 0.00 | 0.00 | 0.353367E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
Maximum of Months | 3071112.35 | 0.974363E+10 | 0.00 | 428906.19 | 0.601346E+09 | 0.00 | 7888398.40 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 1621243.64 | 0.104915E+11 | 0.00 | 656072.55 | 0.257084E+09 | 0.00 | 7407924.97 | 0.00 | 0.42 |
February | 0.00 | 0.105927E+11 | 0.00 | 160606.27 | 0.299480E+09 | 0.00 | 22409.13 | 0.00 | 0.42 |
March | 0.00 | 0.130157E+11 | 0.00 | 0.00 | 0.286367E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
April | 0.00 | 0.154644E+11 | 0.00 | 0.00 | 0.398244E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
May | 0.00 | 0.185542E+11 | 0.00 | 0.00 | 0.367450E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
June | 0.00 | 0.188741E+11 | 0.00 | 0.00 | 0.350279E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 0.00 | 0.131290E+11 | 0.00 | 0.00 | 0.384200E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.171536E+11 | 0.00 | 0.00 | 0.348087E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.155465E+11 | 0.00 | 132960.30 | 0.382183E+09 | 0.00 | 35465.04 | 0.00 | 0.43 |
October | 0.00 | 0.145637E+11 | 0.00 | 36800.19 | 0.373029E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
November | 284128.13 | 0.126870E+11 | 0.00 | 334552.15 | 0.281958E+09 | 0.00 | 1210762.17 | 0.00 | 0.43 |
December | 0.00 | 0.108615E+11 | 0.00 | 301795.86 | 0.327805E+09 | 0.00 | 420232.58 | 0.00 | 0.42 |
Annual Sum or Average | 1905371.77 | 0.170934E+12 | 0.00 | 1622787.31 | 0.405617E+10 | 0.00 | 9096793.88 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.104915E+11 | 0.00 | 0.00 | 0.257084E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 1621243.64 | 0.188741E+11 | 0.00 | 656072.55 | 0.398244E+09 | 0.00 | 7407924.97 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 963108.27 | 0.522289E+10 | 0.00 | 325024.27 | 0.126018E+09 | 0.00 | 3640951.72 | 0.00 | 0.42 |
February | 0.00 | 0.527268E+10 | 0.00 | 85172.05 | 0.149551E+09 | 0.00 | 9576.21 | 0.00 | 0.42 |
March | 0.00 | 0.648250E+10 | 0.00 | 0.00 | 0.145006E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
April | 0.00 | 0.769902E+10 | 0.00 | 0.00 | 0.198707E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
May | 0.00 | 0.923176E+10 | 0.00 | 0.00 | 0.183993E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
June | 0.00 | 0.939310E+10 | 0.00 | 0.00 | 0.170358E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 0.00 | 0.652341E+10 | 0.00 | 0.00 | 0.191061E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.852246E+10 | 0.00 | 0.00 | 0.171439E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.772487E+10 | 0.00 | 66496.43 | 0.187397E+09 | 0.00 | 35352.41 | 0.00 | 0.43 |
October | 0.00 | 0.723008E+10 | 0.00 | 23494.97 | 0.185195E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
November | 190453.10 | 0.629736E+10 | 0.00 | 177039.87 | 0.142649E+09 | 0.00 | 627303.09 | 0.00 | 0.43 |
December | 10411.43 | 0.539647E+10 | 0.00 | 143527.46 | 0.163246E+09 | 0.00 | 249203.64 | 0.00 | 0.42 |
Annual Sum or Average | 1163972.79 | 0.849966E+11 | 0.00 | 820755.04 | 0.201462E+10 | 0.00 | 4562387.07 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.522289E+10 | 0.00 | 0.00 | 0.126018E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 963108.27 | 0.939310E+10 | 0.00 | 325024.27 | 0.198707E+09 | 0.00 | 3640951.72 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 979528.25 | 0.520860E+10 | 0.00 | 318597.43 | 0.126176E+09 | 0.00 | 3781891.86 | 0.00 | 0.42 |
February | 0.00 | 0.525873E+10 | 0.00 | 83619.79 | 0.151487E+09 | 0.00 | 11451.82 | 0.00 | 0.42 |
March | 0.00 | 0.646727E+10 | 0.00 | 0.00 | 0.146588E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
April | 0.00 | 0.768560E+10 | 0.00 | 0.00 | 0.198413E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
May | 0.00 | 0.921626E+10 | 0.00 | 0.00 | 0.184032E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
June | 0.00 | 0.937809E+10 | 0.00 | 0.00 | 0.170122E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 0.00 | 0.650884E+10 | 0.00 | 0.00 | 0.190700E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.850529E+10 | 0.00 | 0.00 | 0.170934E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.770984E+10 | 0.00 | 65676.27 | 0.186487E+09 | 0.00 | 35915.86 | 0.00 | 0.43 |
October | 0.00 | 0.720901E+10 | 0.00 | 23249.06 | 0.187867E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
November | 196862.13 | 0.628086E+10 | 0.00 | 175417.95 | 0.142230E+09 | 0.00 | 630122.55 | 0.00 | 0.43 |
December | 10521.96 | 0.538242E+10 | 0.00 | 141211.94 | 0.161593E+09 | 0.00 | 251614.86 | 0.00 | 0.42 |
Annual Sum or Average | 1186912.33 | 0.848108E+11 | 0.00 | 807772.43 | 0.201663E+10 | 0.00 | 4710996.94 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.520860E+10 | 0.00 | 0.00 | 0.126176E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 979528.25 | 0.937809E+10 | 0.00 | 318597.43 | 0.198413E+09 | 0.00 | 3781891.86 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 886177.09 | 0.519839E+10 | 0.00 | 303929.07 | 0.133263E+09 | 0.00 | 4079615.45 | 0.00 | 0.42 |
February | 0.00 | 0.526234E+10 | 0.00 | 79966.31 | 0.150531E+09 | 0.00 | 10101.42 | 0.00 | 0.42 |
March | 0.00 | 0.646864E+10 | 0.00 | 0.00 | 0.150288E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
April | 0.00 | 0.769371E+10 | 0.00 | 0.00 | 0.200849E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
May | 0.00 | 0.922001E+10 | 0.00 | 0.00 | 0.190248E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
June | 0.00 | 0.938835E+10 | 0.00 | 0.00 | 0.173403E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 0.00 | 0.651103E+10 | 0.00 | 0.00 | 0.196055E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.850061E+10 | 0.00 | 0.00 | 0.180866E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.770610E+10 | 0.00 | 63173.63 | 0.197990E+09 | 0.00 | 35263.03 | 0.00 | 0.43 |
October | 0.00 | 0.720056E+10 | 0.00 | 22032.48 | 0.192088E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
November | 175162.10 | 0.626915E+10 | 0.00 | 166211.16 | 0.149918E+09 | 0.00 | 652619.27 | 0.00 | 0.43 |
December | 9892.15 | 0.537329E+10 | 0.00 | 138276.82 | 0.164946E+09 | 0.00 | 243844.56 | 0.00 | 0.42 |
Annual Sum or Average | 1071231.34 | 0.847922E+11 | 0.00 | 773589.47 | 0.208045E+10 | 0.00 | 5021443.73 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.519839E+10 | 0.00 | 0.00 | 0.133263E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 886177.09 | 0.938835E+10 | 0.00 | 303929.07 | 0.200849E+09 | 0.00 | 4079615.45 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:51
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 727812.23 | 0.539840E+10 | 0.00 | 378038.56 | 0.116877E+09 | 0.00 | 4382770.92 | 0.00 | 0.42 |
February | 931.29 | 0.548295E+10 | 0.00 | 198446.89 | 0.137215E+09 | 0.00 | 99624.54 | 0.00 | 0.42 |
March | 0.00 | 0.669642E+10 | 0.00 | 0.00 | 0.126222E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
April | 0.00 | 0.795782E+10 | 0.00 | 0.00 | 0.191485E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
May | 0.00 | 0.947008E+10 | 0.00 | 0.00 | 0.181966E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
June | 0.00 | 0.967488E+10 | 0.00 | 0.00 | 0.167116E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 0.00 | 0.678576E+10 | 0.00 | 0.00 | 0.188594E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
August | 0.00 | 0.878190E+10 | 0.00 | 0.00 | 0.163498E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
September | 0.00 | 0.799727E+10 | 0.00 | 66301.31 | 0.190215E+09 | 0.00 | 49511.49 | 0.00 | 0.43 |
October | 0.00 | 0.742692E+10 | 0.00 | 34049.22 | 0.181153E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
November | 32561.50 | 0.650833E+10 | 0.00 | 221721.14 | 0.131470E+09 | 0.00 | 443725.55 | 0.00 | 0.43 |
December | 4606.26 | 0.558903E+10 | 0.00 | 173989.66 | 0.143569E+09 | 0.00 | 453698.02 | 0.00 | 0.42 |
Annual Sum or Average | 765911.28 | 0.877698E+11 | 0.00 | 1072546.79 | 0.191938E+10 | 0.00 | 5429330.52 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.539840E+10 | 0.00 | 0.00 | 0.116877E+09 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 727812.23 | 0.967488E+10 | 0.00 | 378038.56 | 0.191485E+09 | 0.00 | 4382770.92 | 0.00 | 0.43 |