Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:20
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** Honolulu Intl Arpt HI USA TMY3 WMO#=911820
Simulation Timestamp: 2020-06-03 19:20:23
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1168.79 | 559.14 | 559.14 |
Net Site Energy | 1168.79 | 559.14 | 559.14 |
Total Source Energy | 3701.56 | 1770.81 | 1770.81 |
Net Source Energy | 3701.56 | 1770.81 | 1770.81 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 430.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 402.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 59.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 89.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 58.58 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1168.79 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 430.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 402.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 59.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 89.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 58.58 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 221.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 276.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 559.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 221.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 276.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 559.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1168.791 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1168.791 | 100.00 |
Total On-Site and Utility Electric Sources | 1168.791 | 100.00 |
Total Electricity End Uses | 1168.791 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 391.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_HI_HONOLULU
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:20 |
RunPeriod | RUNPERIOD 1 |
Weather File | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
Latitude [deg] | 21.32 |
Longitude [deg] | -157.9 |
Elevation [m] | 2.00 |
Time Zone | -10.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 15.2783 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 18.1523 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 16.5377 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 16.5377 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 16.5377 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 9.5842 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 9.5842 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 9.5842 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 9.5842 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 9.5842 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 12.9856 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 12.9856 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 03-SEP-13:09 | - | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 51691.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 25772.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 8604.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 5412.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 99539.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 51691.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 25772.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 8604.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 5412.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1363.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1274.89 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 188.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 405.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 283.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 185.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3701.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 652.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 609.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 90.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 135.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 88.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1770.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 652.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 609.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 90.08 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 135.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 88.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1770.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 1.83 |
SMSTORE1 DIRECT AIR | 0.969760 |
SMSTORE2 DIRECT AIR | 1.00 |
SMSTORE3 DIRECT AIR | 0.996880 |
SMSTORE4 DIRECT AIR | 0.991718 |
LGSTORE2 DIRECT AIR | 1.66 |
SMSTORE5 DIRECT AIR | 0.864625 |
SMSTORE6 DIRECT AIR | 0.858452 |
SMSTORE7 DIRECT AIR | 0.858827 |
SMSTORE8 DIRECT AIR | 0.992916 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 1.83 | 1.83 | 1.83 | 1.83 | 1.83 | 1.83 | 1.00 | 1.00 | 1.83 |
PSZ-AC_2:2 | 0.969760 | 0.969760 | 0.969760 | 0.969760 | 0.969760 | 0.969760 | 1.00 | 1.000000 | 0.969760 |
PSZ-AC_3:3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PSZ-AC_4:4 | 0.996880 | 0.996880 | 0.996880 | 0.996880 | 0.996880 | 0.996880 | 1.00 | 1.000000 | 0.996880 |
PSZ-AC_5:5 | 0.991718 | 0.991718 | 0.991718 | 0.991718 | 0.991718 | 0.991718 | 1.00 | 1.00 | 0.991718 |
PSZ-AC_6:6 | 1.66 | 1.66 | 1.66 | 1.66 | 1.66 | 1.66 | 1.00 | 1.00 | 1.66 |
PSZ-AC_7:7 | 0.864625 | 0.864625 | 0.864625 | 0.864625 | 0.864625 | 0.864625 | 1.00 | 1.000000 | 0.864625 |
PSZ-AC_8:8 | 0.858452 | 0.858452 | 0.858452 | 0.858452 | 0.858452 | 0.858452 | 1.00 | 1.00 | 0.858452 |
PSZ-AC_9:9 | 0.858827 | 0.858827 | 0.858827 | 0.858827 | 0.858827 | 0.858827 | 1.00 | 0.999999 | 0.858827 |
PSZ-AC_10:10 | 0.992916 | 0.992916 | 0.992916 | 0.992916 | 0.992916 | 0.992916 | 1.00 | 1.000000 | 0.992916 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 1.83 | 0.411453 |
PSZ-AC_2:2_OA_CONTROLLER | 0.969760 | 0.205727 |
PSZ-AC_3:3_OA_CONTROLLER | 1.00 | 0.205727 |
PSZ-AC_4:4_OA_CONTROLLER | 0.996880 | 0.205727 |
PSZ-AC_5:5_OA_CONTROLLER | 0.991718 | 0.205727 |
PSZ-AC_6:6_OA_CONTROLLER | 1.66 | 0.411453 |
PSZ-AC_7:7_OA_CONTROLLER | 0.864625 | 0.205727 |
PSZ-AC_8:8_OA_CONTROLLER | 0.858452 | 0.205727 |
PSZ-AC_9:9_OA_CONTROLLER | 0.858827 | 0.205727 |
PSZ-AC_10:10_OA_CONTROLLER | 0.992916 | 0.205727 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 1.83 | 1.83 | 1.83 | 1.21 | 43070.75 | 44248.97 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 0.969760 | 0.969760 | 0.969760 | 0.640042 | 22657.89 | 23385.13 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 1.00 | 1.00 | 1.00 | 0.661623 | 23405.76 | 24132.10 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 0.996880 | 0.996880 | 0.996880 | 0.657941 | 23255.92 | 24004.58 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 0.991718 | 0.991718 | 0.991718 | 0.654534 | 23206.33 | 24114.03 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 1.66 | 1.66 | 1.66 | 1.10 | 40063.09 | 40382.91 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 0.864625 | 0.864625 | 0.864625 | 0.570653 | 20830.36 | 21245.64 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 0.858452 | 0.858452 | 0.858452 | 0.566578 | 20721.89 | 20840.83 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 0.858827 | 0.858827 | 0.858827 | 0.566826 | 20728.48 | 20849.54 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 0.992916 | 0.992916 | 0.992916 | 0.655325 | 22960.11 | 24250.39 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 1.83 | 0.914600 | 1.22 | 40856.69 | 43070.75 | 21535.38 | 21535.38 | 0.689470 | 0.689470 | 0.689470 | 0.689470 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 0.969760 | 0.484880 | 0.646507 | 21481.34 | 22657.89 | 11328.94 | 11328.94 | 0.691481 | 0.691480 | 0.691480 | 0.691480 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 1.00 | 0.501230 | 0.668307 | 22189.29 | 23405.76 | 11702.88 | 11702.88 | 0.691661 | 0.691660 | 0.691660 | 0.691660 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 0.996880 | 0.498440 | 0.664587 | 22045.92 | 23255.92 | 11627.96 | 11627.96 | 0.691880 | 0.691880 | 0.691880 | 0.691880 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 0.991720 | 0.495860 | 0.661147 | 22003.72 | 23206.33 | 11603.17 | 11603.17 | 0.691085 | 0.691080 | 0.691080 | 0.691080 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 1.66 | 0.830030 | 1.11 | 38068.54 | 40063.09 | 20031.54 | 20031.54 | 0.683180 | 0.683180 | 0.683180 | 0.683180 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 0.864630 | 0.432315 | 0.576420 | 19791.05 | 20830.36 | 10415.18 | 10415.18 | 0.683619 | 0.683620 | 0.683620 | 0.683620 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 0.858450 | 0.429225 | 0.572300 | 19690.45 | 20721.89 | 10360.94 | 10360.94 | 0.683126 | 0.683130 | 0.683130 | 0.683130 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 0.858830 | 0.429415 | 0.572553 | 19696.67 | 20728.48 | 10364.24 | 10364.24 | 0.683157 | 0.683160 | 0.683160 | 0.683160 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 0.992920 | 0.496460 | 0.661947 | 21753.68 | 22960.11 | 11480.06 | 11480.06 | 0.694192 | 0.694190 | 0.694190 | 0.694190 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.83 | 1957.33 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 0.969760 | 1073.68 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.00 | 1109.88 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.996880 | 1103.70 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 0.991718 | 1097.99 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 1.66 | 1776.34 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 0.864625 | 957.28 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 0.858452 | 950.44 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 0.858827 | 950.86 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 0.992916 | 1099.32 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 44248.97 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 23385.13 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 24132.10 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 24004.58 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 24114.03 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 40382.91 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 21245.64 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 20840.83 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 20849.54 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 24250.39 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 26.20 | 24.80 | 23.70 | 22.50 | 22.80 | 23.20 | 23.80 | 25.20 | 25.90 | 26.90 | 27.10 | 26.90 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Honolulu Intl Arpt HI USA TMY3 WMO#=911820 | 21.32 | -157.93 | -10.00 | 2.00 | 101301 | 1.2040 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 24.92 | 4.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 15.278 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 19.578 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 18.152 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 22.452 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 16.538 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.838 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 16.538 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.838 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 16.538 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.838 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 9.584 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 13.884 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 9.584 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 13.884 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 9.584 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 13.884 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 9.584 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 13.884 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 9.584 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 13.884 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 3339.000 | 9.584 | 111.314 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3339.000 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 1983.750 | 5.694 | 66.134 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1983.750 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1492.500 | 8.568 | 99.513 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1492.500 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 1211.250 | 6.953 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.250 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 1211.250 | 6.953 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.250 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 1211.250 | 6.953 | 80.761 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1211.250 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 3339.000 | 9.584 | 111.314 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3339.000 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 1669.500 | 9.584 | 111.315 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1669.500 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.7871 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1995 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.1125 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2888 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.037 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.937 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 8.813 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.386 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1010000 | 2.1010000 | 2.1010000 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
19 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
20 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
21 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
22 | 7 | -0.29735092E-12 | 0.24575595E-14 | -0.94456721E-13 | 0.15324278E-15 |
23 | 6 | 0.28546880E-07 | 0.22114619E-09 | 0.65405332E-08 | -0.13451374E-12 |
24 | 5 | -0.18947583E-03 | 0.18937623E-05 | -0.97466953E-04 | 0.64660656E-08 |
25 | 4 | 0.29140875 | 0.92215111E-03 | 0.99417931E-01 | -0.33466744E-04 |
26 | 3 | -7.2517161 | 0.28579858E-01 | -2.3345767 | 0.28937395E-01 |
27 | 2 | 40.822959 | 0.10163225 | 15.247323 | -0.33280368 |
28 | 1 | -80.508872 | 0.45869584E-01 | -29.125752 | 1.0778326 |
29 | 0 | 46.824339 | 0.92288667E-03 | 16.291614 | |
30 | 7 | -0.21163652E-08 | -0.68723841E-15 | 0.43910983E-14 | -0.57684426E-16 |
31 | 6 | 0.56109385E-05 | 0.38186281E-08 | 0.31898696E-02 | -0.26759299E-04 |
32 | 5 | -0.40164657E-03 | 0.22608617E-05 | -0.22372456 | 0.19561502E-02 |
33 | 4 | 0.92272104E-02 | 0.10289840E-03 | 4.8295456 | -0.45264980E-01 |
34 | 3 | -0.80993241E-01 | 0.81813938E-03 | -38.021416 | 0.39865375 |
35 | 2 | 0.28754352 | 0.13608947E-02 | 116.48395 | -1.4179393 |
36 | 1 | -0.41499682 | 0.41453381E-03 | -143.90731 | 2.0490399 |
37 | 0 | 0.20232414 | 0.10048102E-04 | 60.838472 | |
38 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
39 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
40 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
41 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
42 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
43 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
44 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
45 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
46 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
47 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
48 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
49 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
50 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
51 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
52 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
53 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
54 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
55 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
56 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
57 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
58 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
59 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
60 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
61 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
62 | 7 | -0.37862368E-08 | -0.38757603E-14 | 0.11479940E-14 | -0.41635801E-16 |
63 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
64 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
65 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
66 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
67 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
68 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
69 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
70 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
71 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
72 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
73 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
74 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
75 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
76 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
77 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
78 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479937E-14 | -0.41635796E-16 |
79 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
80 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
81 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
82 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
83 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
84 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
85 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
86 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479940E-14 | -0.41635801E-16 |
87 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
88 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
89 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
90 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
91 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
92 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
93 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
94 | 7 | -0.37862368E-08 | -0.38757604E-14 | 0.11479936E-14 | -0.41635794E-16 |
95 | 6 | 0.33337596E-05 | 0.21524044E-08 | 0.31966530E-02 | -0.26816204E-04 |
96 | 5 | -0.22954206E-03 | 0.12712390E-05 | -0.22411006 | 0.19595528E-02 |
97 | 4 | 0.52129973E-02 | 0.57790281E-04 | 4.8359653 | -0.45326691E-01 |
98 | 3 | -0.45565888E-01 | 0.45899116E-03 | -38.057676 | 0.39905455 |
99 | 2 | 0.16149801 | 0.76278124E-03 | 116.55452 | -1.4188832 |
100 | 1 | -0.23290653 | 0.23201668E-03 | -143.94884 | 2.0497227 |
101 | 0 | 0.11350612 | 0.56387423E-05 | 60.838472 | |
102 | 7 | -0.14484255E-08 | -0.22640907E-15 | 0.11860658E-13 | -0.17473455E-15 |
103 | 6 | 0.80640390E-05 | 0.55493782E-08 | 0.31828288E-02 | -0.26700235E-04 |
104 | 5 | -0.58275339E-03 | 0.32892043E-05 | -0.22332434 | 0.19526176E-02 |
105 | 4 | 0.13421983E-01 | 0.14977251E-03 | 4.8228790 | -0.45200897E-01 |
106 | 3 | -0.11791368 | 0.11914425E-02 | -37.983753 | 0.39823745 |
107 | 2 | 0.41875064 | 0.19825898E-02 | 116.41064 | -1.4169588 |
108 | 1 | -0.60444169 | 0.60433957E-03 | -143.86415 | 2.0483306 |
109 | 0 | 0.29470347 | 0.14596444E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 29 | 1 | VerySmooth | 2.843 | 0.232 | 0.142 | 0.254 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 1.97990E-002 | 0.14129 | 0.63099 | 0.63099 | 0.25300 | 0.16079 | 0.23715 | 0.00000 | 0.84000 | 0.84000 | 0.10909 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7252 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.159 | 4.569E-004 | 2.517E-004 | 0.317 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 6.149E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 4.561E-002 | 2.619E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.648E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 9.122E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.389 | 1.116E-003 | 7.565E-004 | 0.776 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 8.649E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.113 | 6.514E-004 | 3.022E-004 | 0.453 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.222 | 1.276E-003 | 5.921E-004 | 0.887 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 20764.40191 | 24917.28229 | 1.52433 | 1.82920 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 31.98700 | 1.43490E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
2 | LGSTORE1 | Heating | 6309.95661 | 7571.94793 | 0.26336 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
3 | SMSTORE1 | Cooling | 11008.19965 | 13209.83958 | 0.80813 | 0.96976 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 32.20000 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
4 | SMSTORE1 | Heating | 2866.76369 | 3440.11643 | 0.12025 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
5 | SMSTORE2 | Cooling | 11709.28673 | 14051.14407 | 0.83538 | 1.00246 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 28.29500 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
6 | SMSTORE2 | Heating | 2719.11962 | 3262.94354 | 0.11725 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
7 | SMSTORE3 | Cooling | 11646.28818 | 13975.54582 | 0.83073 | 0.99688 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 28.29500 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
8 | SMSTORE3 | Heating | 2752.71647 | 3303.25976 | 0.11870 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
9 | SMSTORE4 | Cooling | 11587.26434 | 13904.71720 | 0.82643 | 0.99172 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 28.29500 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
10 | SMSTORE4 | Heating | 2860.66262 | 3432.79514 | 0.12335 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
11 | LGSTORE2 | Cooling | 18844.68938 | 22613.62726 | 1.38338 | 1.66006 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 32.20000 | 1.43490E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
12 | LGSTORE2 | Heating | 6581.61910 | 7897.94292 | 0.27408 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
13 | SMSTORE5 | Cooling | 9814.83627 | 11777.80352 | 0.72052 | 0.86463 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 32.20000 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
14 | SMSTORE5 | Heating | 3404.55037 | 4085.46045 | 0.14235 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
15 | SMSTORE6 | Cooling | 9744.76433 | 11693.71719 | 0.71538 | 0.85845 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 32.20000 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
16 | SMSTORE6 | Heating | 3412.53466 | 4095.04159 | 0.14268 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
17 | SMSTORE7 | Cooling | 9749.06351 | 11698.87621 | 0.71569 | 0.85883 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 32.14083 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
18 | SMSTORE7 | Heating | 3674.56329 | 4409.47595 | 0.15336 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
19 | SMSTORE8 | Cooling | 11272.76573 | 13527.31887 | 0.82743 | 0.99292 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 31.84500 | 1.43490E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
20 | SMSTORE8 | Heating | 4352.20137 | 5222.64164 | 0.18110 | 0.21733 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 16.20000 | 1.15180E-002 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 28634.02 | 1.82920 | 1.82920 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 11847.79 | 0.41145 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:30:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 15075.27 | 0.96976 | 0.96976 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:50:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 15109.54 | 1.00246 | 1.00246 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 15151.37 | 0.99688 | 0.99688 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 15000.18 | 0.99172 | 0.99172 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 26403.17 | 1.66006 | 1.66006 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 11847.79 | 0.41145 | 0.41145 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 13665.36 | 0.86463 | 0.86463 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 13582.57 | 0.85845 | 0.85845 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 11:30:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 13587.60 | 0.85883 | 0.85883 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 5923.90 | 0.20573 | 0.20573 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 15299.05 | 0.99292 | 0.99292 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 6193.93 | 0.21733 | 0.21733 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.82920 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.96976 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00246 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.99688 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.99172 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.66006 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.86463 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.85845 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.85883 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.99292 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.82920 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.82920 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.82920 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.82920 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.82920 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.82920 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.96976 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.96976 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.96976 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.96976 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.96976 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.96976 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 1.00000 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00246 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00246 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00246 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00246 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00246 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.00246 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.99688 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.99688 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.99688 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.99688 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.99688 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.99688 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.99172 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.99172 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.99172 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.99172 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.99172 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 0.99172 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 1.00000 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.66006 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.66006 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.66006 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.66006 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.66006 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 1.66006 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 1.00000 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.86463 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.86463 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.86463 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.86463 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.86463 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 0.86463 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 1.00000 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.85845 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.85845 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.85845 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.85845 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.85845 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 0.85845 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 1.00000 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.85883 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.85883 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.85883 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.85883 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.85883 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 0.85883 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 1.00000 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.99292 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.99292 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.99292 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.99292 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.99292 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 0.99292 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 1.00000 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 1.82920 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 0.96976 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 1.00246 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 0.99688 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 0.99172 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 1.66006 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 0.86463 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 0.85845 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 0.85883 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 0.99292 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.82920 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.82920 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.82920 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.82920 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.20727 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.82920 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.91460 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.21947 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 40856.68925 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 43070.75000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 21535.37500 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 21535.37500 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68947 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68947 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68947 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68947 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 43070.75000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 44248.97379 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.82920 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1957.33013 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 44248.97379 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.96976 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.96976 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.96976 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.96976 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.64004 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.96976 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.48488 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.64651 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21481.34475 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22657.89000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11328.94500 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11328.94500 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69148 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69148 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69148 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69148 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22657.89000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 23385.12842 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.96976 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1073.67820 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 23385.12842 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00246 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00246 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00246 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00246 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66162 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.00246 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50123 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66831 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22189.29450 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23405.76000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11702.88000 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11702.88000 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69166 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69166 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69166 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69166 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23405.76000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 24132.09806 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.00246 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1109.88206 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 24132.09806 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.99688 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.99688 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.99688 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.99688 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.65794 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.99688 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.49844 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66459 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22045.92155 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23255.92000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11627.96000 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11627.96000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69188 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69188 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69188 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69188 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23255.92000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 24004.57666 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.99688 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1103.70441 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 24004.57666 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.99172 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.99172 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.99172 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.99172 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.65453 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.99172 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.49586 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66115 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22003.72390 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23206.33000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11603.16500 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11603.16500 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69108 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69108 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69108 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69108 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23206.33000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 24114.02997 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.99172 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1097.98944 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 24114.02997 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.66006 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.66006 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.66006 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.66006 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.09564 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.66006 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.83003 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.10671 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 38068.53767 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 40063.09000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 20031.54500 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 20031.54500 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68318 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68318 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68318 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68318 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 40063.09000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 40382.90902 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.66006 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1776.34365 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 40382.90902 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.86463 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.86463 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.86463 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.86463 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57065 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.86463 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.43232 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.57642 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 19791.05013 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 20830.36000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10415.18000 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 10415.18000 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68362 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68362 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68362 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68362 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20830.36000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 21245.64044 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.86463 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 957.27761 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 21245.64044 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.85845 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.85845 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.85845 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.85845 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.56658 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.85845 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.42923 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.57230 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 19690.45105 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 20721.89000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10360.94500 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 10360.94500 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68313 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68313 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68313 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68313 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20721.89000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20840.83101 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.85845 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 950.44288 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 20840.83101 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.85883 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.85883 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.85883 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.85883 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.56683 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.85883 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.42942 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.57255 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 19696.66655 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 20728.48000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10364.24000 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 10364.24000 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68316 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68316 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68316 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68316 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20728.48000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 20849.53520 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.85883 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 950.85835 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 20849.53520 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.99292 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.99292 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.99292 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.99292 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.65532 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.99292 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.49646 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66195 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 21753.67612 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22960.11000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11480.05500 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11480.05500 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69419 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69419 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69419 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69419 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22960.11000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 24250.38574 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.99292 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1099.31608 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 24250.38574 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 41629.1 | 11.67 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 21893.7 | 34.35 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 22615.8 | 45.08 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 22470.4 | 57.20 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 22424.8 | 69.19 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 38754.2 | 51.34 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 20148.6 | 112.12 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 20045.0 | 124.63 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 20051.3 | 136.49 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 22177.8 | 134.40 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.199 | 0.190 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 0.112 | 0.109 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 0.112 | 0.109 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.23 | N/A | 2.843 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.787 | 0.704 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.289 | 0.270 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 7 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 2.7295252709E-002 | 0.1200567785 | Pass | Pass | 5.8434521497E-002 | 0.3554765066 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 2.8929068854E-002 | 0.1437368886 | Pass | Pass | 4.9260370041E-002 | 0.2491909076 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 3.8143337271E-002 | 0.1564534632 | Pass | Pass | 0.4198730263 | 2.9470246527 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 3.8005712662E-002 | 0.1564454438 | Pass | Pass | 1.4721302567 | 15.0638642054 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 3.7872396140E-002 | 0.1531189127 | Pass | Pass | 0.3056728975 | 1.9965106021 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 3.7958247583E-002 | 0.1514728811 | Pass | Pass | 0.2485666460 | 1.7395374911 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 3.7034519938E-002 | 0.1485960107 | Pass | Pass | 0.2472042041 | 1.6158350152 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 3.6819426931E-002 | 0.1467137016 | Pass | Pass | 0.2456553087 | 1.6074884619 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 3.6291133340E-002 | 0.1409234669 | Pass | Pass | 1.7349695877 | 18.9991445304 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 4.3249589749E-002 | 0.1494540481 | Pass | Pass | 0.2058241272 | 1.3761437842 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 16.20 | 0.00 | 16.20 | Wetbulb [C] | 1.90 | 320.00 |
HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 32.20 | 7.10 | 23.30 | Wetbulb [C] | 6.70 | 60.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.704 | 0.787 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.199 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.112 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.112 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.289 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.843 | 0.232 | 0.254 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.843 | 0.232 | 0.254 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.843 | 0.232 | 0.254 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.843 | 0.232 | 0.254 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.5_SHGC_0.23 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.843 | 0.232 | 0.254 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 2.843 | 0.232 | 0.254 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 2.843 | 0.232 | 0.254 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 9.5842 | 348.39 | 3339.00 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 168.00 | 96.52 | 0.0000 | Y | 60.49 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 5.6941 | 348.39 | 1983.75 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 112.00 | 95.26 | 0.0000 | Y | 35.47 |
SMSTORE1_LIGHTS | SMSTORE1 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 168.00 | 96.52 | 0.0000 | Y | 30.25 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 8.5681 | 174.19 | 1492.50 | LightsWired | TYPE1_LIGHT_SCH | 98.22 | 112.00 | 95.26 | 0.0000 | Y | 26.69 |
SMSTORE2_LIGHTS | SMSTORE2 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 75.13 | 0.0000 | Y | 23.54 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
SMSTORE3_LIGHTS | SMSTORE3 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 75.13 | 0.0000 | Y | 23.54 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
SMSTORE4_LIGHTS | SMSTORE4 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 75.13 | 0.0000 | Y | 23.54 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 6.9535 | 174.19 | 1211.25 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 84.29 | 73.25 | 0.0000 | Y | 16.65 |
LGSTORE2_LIGHTS | LGSTORE2 | 9.5842 | 348.39 | 3339.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.64 | 0.0000 | Y | 43.02 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.64 | 0.0000 | Y | 21.51 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.64 | 0.0000 | Y | 21.51 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.64 | 0.0000 | Y | 21.51 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 9.5842 | 174.19 | 1669.50 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 68.64 | 0.0000 | Y | 21.51 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 6.4928 | 4180.64 | 27144.00 | 402.56 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 418.40 | AstronomicalClock | - | 41.86 | 41.86 | 3.29 | |
EXTERIOR_LIGHTS_B | 2520.30 | AstronomicalClock | - | 83.86 | 62.86 | 29.74 | |
EXTERIOR_LIGHTS_C | 2520.30 | AstronomicalClock | - | 83.86 | 55.86 | 26.43 | |
Exterior Lighting Total | 5459.01 | 59.45 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 43070.75 | 29695.99 | 13374.76 | 0.69 | 3.73 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22657.89 | 15667.48 | 6990.41 | 0.69 | 3.80 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23405.76 | 16188.83 | 7216.93 | 0.69 | 3.80 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23255.92 | 16090.31 | 7165.61 | 0.69 | 3.80 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23206.33 | 16037.43 | 7168.90 | 0.69 | 3.80 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 40063.09 | 27370.30 | 12692.79 | 0.68 | 3.73 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 20830.36 | 14240.05 | 6590.31 | 0.68 | 3.80 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 20721.89 | 14155.74 | 6566.15 | 0.68 | 3.80 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 20728.48 | 14160.87 | 6567.61 | 0.68 | 3.80 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22960.11 | 15938.68 | 7021.43 | 0.69 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 41629.1 | 11.67 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 21893.7 | 34.35 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 22615.8 | 45.08 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 22470.4 | 57.20 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 22424.8 | 69.19 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 38754.2 | 51.34 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 20148.6 | 112.12 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 20045.0 | 124.63 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 20051.3 | 136.49 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 22177.8 | 134.40 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 44248.97 | 0.81 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 23385.13 | 0.81 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 24132.10 | 0.81 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 24004.58 | 0.81 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 24114.03 | 0.81 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 40382.91 | 0.81 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 21245.64 | 0.81 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 20840.83 | 0.81 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 20849.54 | 0.81 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 24250.39 | 0.81 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.83 | 1957.33 | 1070.05 | 1.00 | 1.33 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.97 | 1073.68 | 1107.16 | 1.00 | 1.41 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.00 | 1109.88 | 1107.16 | 1.00 | 1.40 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.00 | 1103.70 | 1107.16 | 1.00 | 1.40 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.99 | 1097.99 | 1107.16 | 1.00 | 1.40 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.66 | 1776.34 | 1070.05 | 1.00 | 1.34 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.86 | 957.28 | 1107.16 | 1.00 | 1.44 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.86 | 950.44 | 1107.16 | 1.00 | 1.44 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.86 | 950.86 | 1107.16 | 1.00 | 1.44 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.99 | 1099.32 | 1107.16 | 1.00 | 1.40 | General | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.73 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 20764.40 | 24917.28 | 71.52 | 1.524 | 1.829 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.88 | 0.00993 | 31.99 | 0.01435 | 0.411 | 0.00 |
SMSTORE1 | 11008.20 | 13209.84 | 75.83 | 0.808 | 0.970 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 23.89 | 23.88 | 0.00996 | 32.20 | 0.01435 | 0.206 | 0.00 |
SMSTORE2 | 11709.29 | 14051.14 | 80.66 | 0.835 | 1.002 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00945 | 28.30 | 0.01435 | 0.206 | 0.00 |
SMSTORE3 | 11646.29 | 13975.55 | 80.23 | 0.831 | 0.997 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00943 | 28.30 | 0.01435 | 0.206 | 0.00 |
SMSTORE4 | 11587.26 | 13904.72 | 79.82 | 0.826 | 0.992 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00948 | 28.30 | 0.01435 | 0.206 | 0.00 |
LGSTORE2 | 18844.69 | 22613.63 | 64.91 | 1.383 | 1.660 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 23.89 | 23.89 | 0.01002 | 32.20 | 0.01435 | 0.411 | 0.00 |
SMSTORE5 | 9814.84 | 11777.80 | 67.61 | 0.721 | 0.865 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 23.89 | 23.88 | 0.01010 | 32.20 | 0.01435 | 0.206 | 0.00 |
SMSTORE6 | 9744.76 | 11693.72 | 67.13 | 0.715 | 0.858 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 23.89 | 23.88 | 0.01011 | 32.20 | 0.01435 | 0.206 | 0.00 |
SMSTORE7 | 9749.06 | 11698.88 | 67.16 | 0.716 | 0.859 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.88 | 0.01010 | 32.14 | 0.01435 | 0.206 | 0.00 |
SMSTORE8 | 11272.77 | 13527.32 | 77.66 | 0.827 | 0.993 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 23.89 | 23.88 | 0.00994 | 31.85 | 0.01435 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 6309.96 | 7571.95 | 21.73 | 0.263 | 0.411 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00919 | 16.20 | 0.01152 | 0.411 | 0.00 |
SMSTORE1 | 2866.76 | 3440.12 | 19.75 | 0.120 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00913 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE2 | 2719.12 | 3262.94 | 18.73 | 0.117 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 21.11 | 21.11 | 0.00993 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE3 | 2752.72 | 3303.26 | 18.96 | 0.119 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 21.11 | 21.11 | 0.00992 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE4 | 2860.66 | 3432.80 | 19.71 | 0.123 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 13:00:00 | 21.11 | 21.11 | 0.00988 | 16.20 | 0.01152 | 0.206 | 0.00 |
LGSTORE2 | 6581.62 | 7897.94 | 22.67 | 0.274 | 0.411 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00952 | 16.20 | 0.01152 | 0.411 | 0.00 |
SMSTORE5 | 3404.55 | 4085.46 | 23.45 | 0.142 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00954 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE6 | 3412.53 | 4095.04 | 23.51 | 0.143 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00954 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE7 | 3674.56 | 4409.48 | 25.31 | 0.153 | 0.206 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00947 | 16.20 | 0.01152 | 0.206 | 0.00 |
SMSTORE8 | 4352.20 | 5222.64 | 29.98 | 0.181 | 0.217 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 21.11 | 21.11 | 0.00961 | 16.20 | 0.01152 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 1.83 | 1.83 | 0.41 | 0.41 | 1.8292 | 1.8292 | 1.8292 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 0.97 | 0.97 | 0.21 | 0.21 | 0.9698 | 0.9698 | 0.9698 | 1.0000 | 1.0000 |
PSZ-AC_3:3 | 1.00 | 1.00 | 0.21 | 0.21 | 1.0025 | 1.0025 | 1.0025 | 1.0000 | 1.0000 |
PSZ-AC_4:4 | 1.00 | 1.00 | 0.21 | 0.21 | 0.9969 | 0.9969 | 0.9969 | 1.0000 | 1.0000 |
PSZ-AC_5:5 | 0.99 | 0.99 | 0.21 | 0.21 | 0.9917 | 0.9917 | 0.9917 | 1.0000 | 1.0000 |
PSZ-AC_6:6 | 1.66 | 1.66 | 0.41 | 0.41 | 1.6601 | 1.6601 | 1.6601 | 1.0000 | 1.0000 |
PSZ-AC_7:7 | 0.86 | 0.86 | 0.21 | 0.21 | 0.8646 | 0.8646 | 0.8646 | 1.0000 | 1.0000 |
PSZ-AC_8:8 | 0.86 | 0.86 | 0.21 | 0.21 | 0.8585 | 0.8585 | 0.8585 | 1.0000 | 1.0000 |
PSZ-AC_9:9 | 0.86 | 0.86 | 0.21 | 0.21 | 0.8588 | 0.8588 | 0.8588 | 1.0000 | 1.0000 |
PSZ-AC_10:10 | 0.99 | 0.99 | 0.22 | 0.22 | 0.9929 | 0.9929 | 0.9929 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 21535.375 | 0.000 | 1.829200 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 21535.38 | 15086.66 | 1.829200 | 25.76 | 18.95 | 0.01092394 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 22.4936 | 23.88 | 0.00992598 | 53.6755 | 20732.86 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 44248.974 | 44248.974 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:30:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:30:00 | 44248.97 | 44248.97 | 1.829200 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 22.4936 | 21.11 | 0.00919459 | 58.9173 | 2609.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 11328.945 | 0.000 | 0.969760 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 11328.94 | 7950.88 | 0.969760 | 25.65 | 18.89 | 0.01089090 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 21.2142 | 23.88 | 0.00995976 | 53.8559 | 11008.20 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 23385.128 | 23385.128 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:50:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:50:00 | 23385.13 | 23385.13 | 0.969760 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 21.2142 | 21.11 | 0.00913454 | 58.5386 | 1180.71 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 11702.880 | 0.000 | 1.002460 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 11702.88 | 8217.45 | 1.002460 | 25.64 | 18.88 | 0.01088609 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 20.5222 | 23.89 | 0.00945332 | 51.1560 | 11037.21 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 24132.098 | 24132.098 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 24132.10 | 24132.10 | 1.002460 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 20.5222 | 21.11 | 0.00992550 | 63.5239 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 11627.960 | 0.000 | 0.996880 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 11627.96 | 8169.87 | 0.996880 | 25.64 | 18.88 | 0.01088022 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 20.6371 | 23.89 | 0.00942822 | 51.0215 | 11072.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 24004.577 | 24004.577 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 24004.58 | 24004.58 | 0.996880 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 20.6371 | 21.11 | 0.00991550 | 63.4609 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 11603.165 | 0.000 | 0.991720 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 11603.17 | 8134.26 | 0.991720 | 25.66 | 18.90 | 0.01090158 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 20.7444 | 23.89 | 0.00948102 | 51.3039 | 10944.64 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 24114.030 | 24114.030 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | 24114.03 | 24114.03 | 0.991718 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 20.7445 | 21.11 | 0.00987821 | 63.2259 | 1869.40 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 20031.545 | 0.000 | 1.660060 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 20031.54 | 13799.99 | 1.660060 | 25.95 | 19.14 | 0.01109431 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 24.7855 | 23.89 | 0.01002179 | 54.1850 | 18844.69 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 40382.909 | 40382.909 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 40382.91 | 40382.91 | 1.660061 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 24.7854 | 21.11 | 0.00951876 | 60.9621 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 10415.180 | 0.000 | 0.864630 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 10415.18 | 7150.49 | 0.864630 | 25.86 | 19.13 | 0.01110812 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 23.7936 | 23.88 | 0.01009622 | 54.5818 | 9814.84 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 21245.640 | 21245.640 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | 21245.64 | 21245.64 | 0.864625 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 23.7937 | 21.11 | 0.00953770 | 61.0812 | 1146.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 10360.945 | 0.000 | 0.858450 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 10360.94 | 7103.54 | 0.858450 | 25.88 | 19.14 | 0.01112209 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 23.9649 | 23.88 | 0.01010503 | 54.6286 | 9744.76 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 20840.831 | 20840.831 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 11:30:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 11:30:00 | 20840.83 | 20840.83 | 0.858452 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 23.9648 | 21.11 | 0.00953738 | 61.0792 | 1919.03 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 10364.240 | 0.000 | 0.858830 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 10364.24 | 7106.39 | 0.858830 | 25.88 | 19.14 | 0.01112124 | 12.80 | 12.10 | 0.00850000 | 32.20 | 0.01434902 | 23.30 | 23.9543 | 23.88 | 0.01010324 | 54.6191 | 9749.03 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 20849.535 | 20849.535 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 20849.54 | 20849.54 | 0.858827 | 16.20 | 16.20 | 0.01151798 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 23.9544 | 21.11 | 0.00946641 | 60.6313 | 0.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 11480.055 | 0.000 | 0.992920 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 11480.06 | 8071.51 | 0.992920 | 25.54 | 18.83 | 0.01085745 | 12.80 | 12.10 | 0.00850000 | 31.85 | 0.01434902 | 23.20 | 20.7194 | 23.88 | 0.00994495 | 53.7765 | 11272.77 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 24250.386 | 24250.386 | -999.0 | -999.0 | -999.000 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 24250.39 | 24250.39 | 0.992916 | 16.44 | 16.20 | 0.01141639 | 40.00 | 21.15 | 0.00800000 | 16.20 | 0.01151798 | 16.20 | 20.7194 | 21.11 | 0.00961452 | 61.5636 | 4352.20 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21535.375 | 0.000 | 1.829200 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.1471 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 21535.38 | 15086.66 | 1.0000 | 2.20239922 | 1.829200 | 25.76 | 18.95 | 0.01092394 | 53726.0 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21535.38 | 32.20 | 0.01434902 | 23.30 | 0.41145340 | 22.4936 | 23.88 | 0.00992797 | 23.88 | 0.00992598 | 53.6755 | 20732.86 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 44248.974 | 44248.974 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.829200 | 2.20239883 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:30:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:30:00 | 44248.97 | 44248.97 | 1.0000 | 2.20239883 | 1.829200 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 44248.97 | 16.20 | 0.01151798 | 16.20 | 0.41145340 | 22.4936 | 21.11 | 0.00868994 | 21.11 | 0.00919459 | 58.9173 | 2609.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11328.945 | 0.000 | 0.969760 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.0856 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 11328.94 | 7950.88 | 1.0000 | 1.16761353 | 0.969760 | 25.65 | 18.89 | 0.01089090 | 53529.7 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11328.94 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 21.2142 | 23.88 | 0.00995976 | 23.88 | 0.00995976 | 53.8559 | 11008.20 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 23385.128 | 23385.128 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.969760 | 1.16761346 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:50:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:50:00 | 23385.13 | 23385.13 | 1.0000 | 1.16761346 | 0.969760 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23385.13 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 21.2142 | 21.11 | 0.00875550 | 21.11 | 0.00913454 | 58.5386 | 1180.71 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11702.880 | 0.000 | 1.002460 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.0767 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 11702.88 | 8217.45 | 1.0000 | 1.20698509 | 1.002460 | 25.64 | 18.88 | 0.01088609 | 53512.6 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11702.88 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 20.5222 | 23.88 | 0.00995675 | 23.89 | 0.00945332 | 51.1560 | 11037.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24132.098 | 24132.098 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.002460 | 1.20698478 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 24132.10 | 24132.10 | 1.0000 | 1.20698478 | 1.002460 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24132.10 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 20.5222 | 21.11 | 0.00000000 | 21.11 | 0.00992550 | 63.5239 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11627.960 | 0.000 | 0.996880 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.0658 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 11627.96 | 8169.87 | 1.0000 | 1.20026664 | 0.996880 | 25.64 | 18.88 | 0.01088022 | 53491.9 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11627.96 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 20.6371 | 23.88 | 0.00995308 | 23.89 | 0.00942822 | 51.0215 | 11072.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24004.577 | 24004.577 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.996880 | 1.20026665 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 24004.58 | 24004.58 | 1.0000 | 1.20026665 | 0.996880 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24004.58 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 20.6371 | 21.11 | 0.00000000 | 21.11 | 0.00991550 | 63.4609 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11603.165 | 0.000 | 0.991720 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.1055 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 11603.17 | 8134.26 | 1.0000 | 1.19405388 | 0.991720 | 25.66 | 18.90 | 0.01090158 | 53567.4 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11603.17 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 20.7444 | 23.88 | 0.00996646 | 23.89 | 0.00948102 | 51.3039 | 10944.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24114.030 | 24114.030 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.991718 | 1.19405167 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | 24114.03 | 24114.03 | 1.0000 | 1.19405167 | 0.991718 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24114.03 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 20.7445 | 20.87 | 0.00940585 | 21.11 | 0.00987821 | 63.2259 | 1869.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 20031.545 | 0.000 | 1.660060 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.4638 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 20031.54 | 13799.99 | 1.0000 | 1.99875074 | 1.660060 | 25.95 | 19.14 | 0.01109431 | 54352.9 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20031.54 | 32.20 | 0.01434902 | 23.30 | 0.41145340 | 24.7855 | 23.89 | 0.01002179 | 23.89 | 0.01002179 | 54.1850 | 18844.69 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 40382.909 | 40382.909 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.660061 | 1.99875184 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 40382.91 | 40382.91 | 1.0000 | 1.99875184 | 1.660061 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40382.91 | 16.20 | 0.01151798 | 16.20 | 0.41145340 | 24.7854 | 21.11 | 0.00000000 | 21.11 | 0.00951876 | 60.9621 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 10415.180 | 0.000 | 0.864630 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.4894 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 10415.18 | 7150.49 | 1.0000 | 1.04103457 | 0.864630 | 25.86 | 19.13 | 0.01110812 | 54303.3 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10415.18 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 23.7936 | 23.88 | 0.01009622 | 23.88 | 0.01009622 | 54.5818 | 9814.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 21245.640 | 21245.640 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.864625 | 1.04102907 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 09:10:00 | 21245.64 | 21245.64 | 1.0000 | 1.04102907 | 0.864625 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21245.64 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 23.7937 | 20.78 | 0.00125308 | 21.11 | 0.00953770 | 61.0812 | 1146.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 10360.945 | 0.000 | 0.858450 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.5154 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 10360.94 | 7103.54 | 1.0000 | 1.03359371 | 0.858450 | 25.88 | 19.14 | 0.01112209 | 54353.5 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10360.94 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 23.9649 | 23.88 | 0.01010503 | 23.88 | 0.01010503 | 54.6286 | 9744.76 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20840.831 | 20840.831 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.858452 | 1.03359639 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 11:30:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 11:30:00 | 20840.83 | 20840.83 | 1.0000 | 1.03359639 | 0.858452 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20840.83 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 23.9648 | 21.11 | 0.00924343 | 21.11 | 0.00953738 | 61.0792 | 1919.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 10364.240 | 0.000 | 0.858830 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.5138 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | 10364.24 | 7106.39 | 1.0000 | 1.03405124 | 0.858830 | 25.88 | 19.14 | 0.01112124 | 54350.4 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 10364.24 | 32.20 | 0.01434902 | 23.30 | 0.20572670 | 23.9543 | 23.88 | 0.01010448 | 23.88 | 0.01010324 | 54.6191 | 9749.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 20849.535 | 20849.535 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.858827 | 1.03404820 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 00:10:00 | 20849.54 | 20849.54 | 1.0000 | 1.03404820 | 0.858827 | 16.20 | 16.20 | 0.01151798 | 45431.0 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20849.54 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 23.9544 | 21.11 | 0.00000000 | 21.11 | 0.00946641 | 60.6313 | 0.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11480.055 | 0.000 | 0.992920 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1025.0235 | 1004.8586 | 1.2040 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | HONOLULU INTL ARPT ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 11480.06 | 8071.51 | 1.0000 | 1.19549871 | 0.992920 | 25.54 | 18.83 | 0.01085745 | 53328.2 | 12.80 | 12.10 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11480.06 | 31.85 | 0.01434902 | 23.20 | 0.20572670 | 20.7194 | 23.89 | 0.00994495 | 23.88 | 0.00994495 | 53.7765 | 11272.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24250.386 | 24250.386 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2040 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.992916 | 1.19549439 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | unknown | unknown | HONOLULU INTL ARPT ANN HTG 99.6% CONDNS DB | 2/21 10:00:00 | 24250.39 | 24250.39 | 1.0000 | 1.19549439 | 0.992916 | 16.44 | 16.20 | 0.01141639 | 45423.5 | 40.00 | 21.15 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24250.39 | 16.20 | 0.01151798 | 16.20 | 0.20572670 | 20.7194 | 20.76 | 0.00961452 | 21.11 | 0.00961452 | 61.5636 | 4352.20 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 5720.83 | 158.17 | 152.50 |
SMSTORE1 | 5596.83 | 73.67 | 69.17 |
SMSTORE2 | 4354.50 | 172.50 | 171.67 |
SMSTORE3 | 4354.17 | 173.33 | 172.33 |
SMSTORE4 | 4346.83 | 191.50 | 189.67 |
LGSTORE2 | 3955.67 | 229.17 | 228.83 |
SMSTORE5 | 3919.83 | 247.50 | 246.83 |
SMSTORE6 | 3913.17 | 256.00 | 255.17 |
SMSTORE7 | 3915.17 | 266.67 | 265.17 |
SMSTORE8 | 3955.00 | 227.00 | 224.17 |
Facility | 5847.83 | 401.00 | 391.17 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 0.00 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 0.00 | 0.50 | 0.00 | 0.00 |
SMSTORE5 | 0.00 | 0.33 | 0.00 | 0.00 |
SMSTORE6 | 0.00 | 0.17 | 0.00 | 0.00 |
SMSTORE7 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 0.00 | 1.00 | 0.00 | 0.00 |
Facility | 0.00 | 1.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.02 | 30.00 | 1805.20 | 0.842 | 0.352 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.704 | 0.387 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.843 | 0.506 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.843 | 0.506 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.843 | 0.506 | 0.000 | 0.000 |
LGSTORE2 | 13.23 | 30.00 | 1805.20 | 0.843 | 0.474 | 0.000 | 0.000 |
SMSTORE5 | 6.62 | 15.00 | 902.60 | 0.843 | 0.540 | 0.000 | 0.000 |
SMSTORE6 | 6.62 | 15.00 | 902.60 | 0.843 | 0.540 | 0.000 | 0.000 |
SMSTORE7 | 6.62 | 15.00 | 902.60 | 0.843 | 0.540 | 0.000 | 0.000 |
SMSTORE8 | 6.62 | 15.00 | 902.60 | 0.843 | 0.565 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.02 | 30.00 | 1805.20 | 0.827 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.127 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.826 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.826 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.826 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.23 | 30.00 | 1805.20 | 0.829 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.62 | 15.00 | 902.60 | 0.829 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.62 | 15.00 | 902.60 | 0.829 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.62 | 15.00 | 902.60 | 0.829 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.62 | 15.00 | 902.60 | 0.829 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
Electricity:Building | 530.71 | 891.83 | 01-JAN-00:20 | 33831.79 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 122.22 | 148.64 | 01-JAN-00:20 | 6390.76 | 01-JAN-10:10 |
InteriorLights:Electricity | 402.56 | 450.00 | 01-JAN-00:20 | 25772.29 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 95.97 | 75.00 | 01-JAN-00:20 | 5047.51 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 402.56 | 450.00 | 01-JAN-00:20 | 25772.29 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 70.06 | 74.32 | 01-JAN-00:20 | 3670.12 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 56.93 | 37.50 | 01-JAN-00:20 | 2998.49 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 50.62 | 74.32 | 01-JAN-00:10 | 3408.34 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 40.20 | 37.50 | 01-JAN-00:10 | 2736.71 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 50.62 | 74.32 | 01-JAN-00:10 | 3408.34 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 40.20 | 37.50 | 01-JAN-00:10 | 2736.71 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 50.62 | 74.32 | 01-JAN-00:10 | 3408.34 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 40.20 | 37.50 | 01-JAN-00:10 | 2736.71 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 62.19 | 148.64 | 01-JAN-00:10 | 4515.30 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 43.02 | 75.00 | 01-JAN-00:10 | 3172.05 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 31.10 | 74.32 | 01-JAN-00:10 | 2257.65 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 21.51 | 37.50 | 01-JAN-00:10 | 1586.02 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 31.10 | 74.32 | 01-JAN-00:10 | 2257.65 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 21.51 | 37.50 | 01-JAN-00:10 | 1586.02 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 31.10 | 74.32 | 01-JAN-00:10 | 2257.65 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 21.51 | 37.50 | 01-JAN-00:10 | 1586.02 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 31.10 | 74.32 | 01-JAN-00:10 | 2257.65 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 21.51 | 37.50 | 01-JAN-00:10 | 1586.02 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.15 | 441.83 | 01-JAN-00:10 | 8059.50 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.25 | 73.64 | 01-JAN-00:10 | 1343.25 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.15 | 441.83 | 01-JAN-00:10 | 8059.50 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.12 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.42 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.17 | 73.64 | 01-JAN-00:10 | 1343.25 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.59 | 36.82 | 01-JAN-00:10 | 671.63 | 01-JAN-11:10 |
Electricity:Plant | 58.58 | 1211.00 | 18-JUN-08:10 | 11780.95 | 05-JAN-14:20 |
WaterSystems:Electricity | 58.58 | 1211.00 | 18-JUN-08:10 | 11780.95 | 05-JAN-14:20 |
Water Heater:WaterSystems:Electricity | 58.58 | 1211.00 | 18-JUN-08:10 | 11780.95 | 05-JAN-14:20 |
ElectricityPurchased:Facility | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
ElectricityPurchased:Plant | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
Cogeneration:ElectricityPurchased | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
ElectricityNet:Plant | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
Cogeneration:ElectricityNet | 1168.79 | 2102.83 | 01-JAN-07:20 | 99539.88 | 03-SEP-13:10 |
Electricity:HVAC | 520.04 | 0.00 | 01-JAN-00:10 | 60481.53 | 03-SEP-13:00 |
Fans:Electricity | 89.40 | 0.00 | 01-JAN-00:10 | 8637.40 | 03-SEP-13:00 |
General:Fans:Electricity | 89.40 | 0.00 | 01-JAN-00:10 | 8637.40 | 03-SEP-13:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 430.64 | 0.00 | 01-JAN-00:10 | 51844.12 | 03-SEP-13:00 |
ExteriorLights:Electricity | 59.45 | 0.00 | 01-JAN-07:20 | 5459.01 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 59.45 | 0.00 | 01-JAN-07:20 | 5459.01 | 01-JAN-06:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:Gas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 2695.12 | 0.00 | 01-JAN-00:10 | 305263.84 | 03-SEP-13:00 |
EnergyTransfer:Building | 910.46 | 0.00 | 01-JAN-00:10 | 99684.17 | 03-SEP-14:10 |
EnergyTransfer:Zone:LGSTORE1 | 189.91 | 0.00 | 01-JAN-00:10 | 17254.24 | 03-SEP-16:10 |
Heating:EnergyTransfer | 3.25 | 0.00 | 01-JAN-00:10 | 17313.54 | 03-SEP-16:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 0.20 | 0.00 | 01-JAN-00:10 | 1652.00 | 09-JUL-07:20 |
Cooling:EnergyTransfer | 907.21 | 0.00 | 01-JAN-00:10 | 99684.17 | 03-SEP-14:10 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 189.71 | 0.00 | 01-JAN-00:10 | 17254.24 | 03-SEP-16:10 |
EnergyTransfer:Zone:SMSTORE1 | 100.96 | 0.00 | 01-JAN-00:10 | 8885.33 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 0.11 | 0.00 | 01-JAN-00:10 | 854.29 | 04-NOV-07:20 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 100.85 | 0.00 | 01-JAN-00:10 | 8885.33 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE2 | 77.39 | 0.00 | 01-JAN-00:10 | 8716.47 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 0.40 | 0.00 | 01-JAN-00:10 | 1906.96 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 76.99 | 0.00 | 01-JAN-00:10 | 8716.47 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE3 | 77.37 | 0.00 | 01-JAN-00:10 | 8731.12 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 0.39 | 0.00 | 01-JAN-00:10 | 1905.33 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 76.97 | 0.00 | 01-JAN-00:10 | 8731.12 | 01-OCT-13:00 |
EnergyTransfer:Zone:SMSTORE4 | 75.21 | 0.00 | 01-JAN-00:10 | 8606.39 | 01-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 0.40 | 0.00 | 01-JAN-00:10 | 1912.33 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 74.81 | 0.00 | 01-JAN-00:10 | 8606.39 | 01-OCT-13:00 |
EnergyTransfer:Zone:LGSTORE2 | 123.62 | 0.00 | 01-JAN-00:10 | 15217.41 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 0.59 | 0.00 | 01-JAN-00:10 | 3875.39 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 123.04 | 0.00 | 01-JAN-00:10 | 15217.41 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE5 | 63.91 | 0.00 | 01-JAN-00:10 | 8029.22 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 0.30 | 0.00 | 01-JAN-00:10 | 1944.43 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 63.62 | 0.00 | 01-JAN-00:10 | 8029.22 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE6 | 63.34 | 0.00 | 01-JAN-00:10 | 7991.89 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 0.30 | 0.00 | 01-JAN-00:10 | 1946.23 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 63.04 | 0.00 | 01-JAN-00:10 | 7991.89 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE7 | 63.11 | 0.00 | 01-JAN-00:10 | 8050.29 | 03-SEP-14:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 0.30 | 0.00 | 01-JAN-00:10 | 1944.20 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 62.81 | 0.00 | 01-JAN-00:10 | 8050.29 | 03-SEP-14:10 |
EnergyTransfer:Zone:SMSTORE8 | 75.64 | 0.00 | 01-JAN-00:10 | 9612.50 | 11-OCT-13:00 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 0.26 | 0.00 | 01-JAN-00:10 | 1878.67 | 03-SEP-16:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 75.38 | 0.00 | 01-JAN-00:10 | 9612.50 | 11-OCT-13:00 |
EnergyTransfer:HVAC | 1784.66 | 0.00 | 01-JAN-00:10 | 211254.20 | 19-AUG-15:00 |
HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
CoolingCoils:EnergyTransfer | 1784.66 | 0.00 | 01-JAN-00:10 | 211254.20 | 19-AUG-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 0.200 | -189.703 | 0.000 | 0.000 | 12.382 | 95.966 | 26.249 | 14.603 | 0.000 | 17.149 | 27.558 | 0.000 | -2.955 | 0.000 | -1.450 | -0.001 |
SMSTORE1 | 0.000 | 0.000 | 0.111 | -100.849 | 0.000 | 0.000 | 6.191 | 56.935 | 13.125 | 7.321 | 0.000 | 9.512 | 9.661 | 0.000 | -1.481 | 0.000 | -0.526 | -0.000 |
SMSTORE2 | 0.000 | 0.000 | 0.396 | -76.987 | 0.000 | 0.000 | 3.719 | 40.199 | 10.421 | 7.293 | 0.000 | 9.328 | 8.006 | 0.000 | -1.649 | 0.000 | -0.725 | 0.000 |
SMSTORE3 | 0.000 | 0.000 | 0.393 | -76.972 | 0.000 | 0.000 | 3.719 | 40.199 | 10.421 | 7.293 | 0.000 | 9.327 | 8.002 | 0.000 | -1.653 | 0.000 | -0.728 | 0.000 |
SMSTORE4 | 0.000 | 0.000 | 0.405 | -74.807 | 0.000 | 0.000 | 3.719 | 40.199 | 10.421 | 7.304 | 0.000 | 9.330 | 5.753 | 0.000 | -1.621 | 0.000 | -0.701 | -0.000 |
LGSTORE2 | 0.000 | 0.000 | 0.587 | -123.034 | 0.000 | 0.000 | 12.763 | 43.019 | 19.173 | 14.588 | 0.000 | 16.403 | 20.835 | 0.000 | -3.053 | 0.000 | -1.282 | -0.001 |
SMSTORE5 | 0.000 | 0.000 | 0.298 | -63.615 | 0.000 | 0.000 | 6.382 | 21.510 | 9.586 | 7.308 | 0.000 | 9.341 | 11.337 | 0.000 | -1.491 | 0.000 | -0.656 | -0.000 |
SMSTORE6 | 0.000 | 0.000 | 0.298 | -63.040 | 0.000 | 0.000 | 6.382 | 21.510 | 9.586 | 7.313 | 0.000 | 9.343 | 10.741 | 0.000 | -1.483 | 0.000 | -0.650 | -0.000 |
SMSTORE7 | 0.000 | 0.000 | 0.298 | -62.809 | 0.000 | 0.000 | 6.382 | 21.510 | 9.586 | 7.312 | 0.000 | 9.343 | 10.493 | 0.000 | -1.477 | 0.000 | -0.638 | -0.000 |
SMSTORE8 | 0.000 | 0.000 | 0.265 | -75.376 | 0.000 | 0.000 | 6.381 | 21.510 | 9.586 | 7.232 | 0.000 | 9.734 | 23.386 | 0.000 | -1.484 | 0.000 | -1.234 | 0.000 |
Total Facility | 0.000 | 0.000 | 3.251 | -907.192 | 0.000 | 0.000 | 68.021 | 402.556 | 128.154 | 87.568 | 0.000 | 108.810 | 135.770 | 0.000 | -18.349 | 0.000 | -8.589 | -0.002 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 24-DEC-08:62 | 0.00 | 0.00 | 0.00 | -31149.11 | 0.00 | 0.00 | 95.45 | 75.00 | 74.62 | 1402.67 | 0.00 | 0.00 | 29654.81 | 0.00 | -0.00 | 0.00 | -153.45 | 0.00 |
SMSTORE1 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -17175.31 | 0.00 | 0.00 | 47.55 | 37.50 | 37.31 | 494.42 | 0.00 | 0.00 | 16652.42 | 0.00 | -0.00 | 0.00 | -93.89 | 0.00 |
SMSTORE2 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -16810.31 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 492.52 | 0.00 | 0.00 | 16339.31 | 0.00 | -0.00 | 0.00 | -96.33 | 0.00 |
SMSTORE3 | 25-DEC-08:62 | 0.00 | 0.00 | 0.00 | -16704.44 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 492.90 | 0.00 | 0.00 | 16232.72 | 0.00 | -0.00 | 0.00 | -95.99 | 0.00 |
SMSTORE4 | 24-DEC-08:62 | 0.00 | 0.00 | 0.00 | -16466.63 | 0.00 | 0.00 | 0.00 | 37.50 | 37.31 | 696.96 | 0.00 | 0.00 | 15777.32 | 0.00 | -0.00 | 0.00 | -82.46 | 0.00 |
LGSTORE2 | 25-DEC-09:02 | 0.00 | 0.00 | 0.00 | -28417.02 | 0.00 | 0.00 | 0.00 | 75.00 | 73.64 | 1796.69 | 0.00 | 0.00 | 26579.64 | 0.00 | -0.00 | 0.00 | -107.95 | 0.00 |
SMSTORE5 | 25-DEC-09:02 | 0.00 | 0.00 | 0.00 | -14684.96 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 898.29 | 0.00 | 0.00 | 13769.60 | 0.00 | -0.00 | 0.00 | -57.24 | 0.00 |
SMSTORE6 | 25-DEC-09:02 | 0.00 | 0.00 | 0.00 | -14586.58 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 899.08 | 0.00 | 0.00 | 13669.38 | 0.00 | -0.00 | 0.00 | -56.20 | 0.00 |
SMSTORE7 | 24-DEC-09:02 | 0.00 | 0.00 | 0.00 | -14421.39 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 1163.11 | 0.00 | 0.00 | 13220.92 | 0.00 | -0.00 | 0.00 | -36.96 | 0.00 |
SMSTORE8 | 24-DEC-09:02 | 0.00 | 0.00 | 0.00 | -16213.06 | 0.00 | 0.00 | 0.00 | 37.50 | 36.82 | 1155.36 | 0.00 | 0.00 | 15035.44 | 0.00 | -0.00 | 0.00 | -52.05 | 0.00 |
Total Facility | 19-DEC-08:62 | 0.00 | 0.00 | 0.00 | -139881.97 | 0.00 | 0.00 | 299.47 | 450.00 | 1452.23 | 6195.59 | 0.00 | 0.00 | 132402.63 | 0.00 | 0.00 | 0.00 | -917.96 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 03-SEP-07:06 | 0.00 | 0.00 | 2947.74 | 0.00 | 0.00 | 0.00 | 89.26 | 75.00 | 74.62 | 152.08 | 0.00 | 297.15 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -3635.85 |
SMSTORE1 | 03-SEP-07:06 | 0.00 | 0.00 | 1447.89 | 0.00 | 0.00 | 0.00 | 44.59 | 37.50 | 37.31 | 76.42 | 0.00 | 154.14 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1797.85 |
SMSTORE2 | 03-SEP-16:02 | 0.00 | 0.00 | 2300.06 | 0.00 | 0.00 | 0.00 | 52.54 | 1440.37 | 373.13 | 415.22 | 0.00 | 2193.82 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6775.14 |
SMSTORE3 | 03-SEP-16:02 | 0.00 | 0.00 | 2298.84 | 0.00 | 0.00 | 0.00 | 52.54 | 1440.37 | 373.13 | 415.04 | 0.00 | 2193.57 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6773.50 |
SMSTORE4 | 03-SEP-16:02 | 0.00 | 0.00 | 2302.21 | 0.00 | 0.00 | 0.00 | 52.54 | 1440.37 | 373.13 | 415.48 | 0.00 | 2194.80 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6778.54 |
LGSTORE2 | 03-SEP-16:02 | 0.00 | 0.00 | 4610.71 | 0.00 | 0.00 | 0.00 | 231.18 | 1669.50 | 746.25 | 829.65 | 0.00 | 3872.60 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -11959.89 |
SMSTORE5 | 03-SEP-16:02 | 0.00 | 0.00 | 2311.29 | 0.00 | 0.00 | 0.00 | 115.59 | 834.75 | 373.13 | 418.04 | 0.00 | 2202.17 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6254.96 |
SMSTORE6 | 03-SEP-16:02 | 0.00 | 0.00 | 2311.76 | 0.00 | 0.00 | 0.00 | 115.59 | 834.75 | 373.13 | 418.29 | 0.00 | 2202.59 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6256.11 |
SMSTORE7 | 03-SEP-16:02 | 0.00 | 0.00 | 2310.59 | 0.00 | 0.00 | 0.00 | 115.59 | 834.75 | 373.13 | 417.69 | 0.00 | 2202.14 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6253.89 |
SMSTORE8 | 03-SEP-16:02 | 0.00 | 0.00 | 2284.14 | 0.00 | 0.00 | 0.00 | 115.59 | 834.75 | 373.13 | 410.44 | 0.00 | 2266.16 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -6284.21 |
Total Facility | 03-SEP-16:02 | -25617.24 | 25617.24 | 20729.60 | -25617.24 | 0.00 | 0.00 | 2742.70 | 17375.63 | 5373.00 | 5000.28 | 0.00 | 25784.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -51388.22 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.8292 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8292 | 0.2249 | 1.0000 | 0.4115 | 0.2249 | ||
PSZ-AC_2:2 | 0.9698 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9698 | 0.2121 | 1.0000 | 0.2057 | 0.2121 | ||
PSZ-AC_3:3 | 1.0025 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0025 | 0.2052 | 1.0000 | 0.2057 | 0.2052 | ||
PSZ-AC_4:4 | 0.9969 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9969 | 0.2064 | 1.0000 | 0.2057 | 0.2064 | ||
PSZ-AC_5:5 | 0.9917 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9917 | 0.2074 | 1.0000 | 0.2057 | 0.2074 | ||
PSZ-AC_6:6 | 1.6601 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.6601 | 0.2479 | 1.0000 | 0.4115 | 0.2479 | ||
PSZ-AC_7:7 | 0.8646 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8646 | 0.2379 | 1.0000 | 0.2057 | 0.2379 | ||
PSZ-AC_8:8 | 0.8585 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8585 | 0.2396 | 1.0000 | 0.2057 | 0.2396 | ||
PSZ-AC_9:9 | 0.8588 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8588 | 0.2395 | 1.0000 | 0.2057 | 0.2395 | ||
PSZ-AC_10:10 | 0.9929 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9929 | 0.2072 | 1.0000 | 0.2057 | 0.2072 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.8292 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.8292 | 1.0000 | 1.0000 | 0.4115 | 0.2249 | ||
PSZ-AC_2:2 | 0.9698 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9698 | 1.0000 | 1.0000 | 0.2057 | 0.2121 | ||
PSZ-AC_3:3 | 1.0025 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 1.0025 | 1.0000 | 1.0000 | 0.2057 | 0.2052 | ||
PSZ-AC_4:4 | 0.9969 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9969 | 1.0000 | 1.0000 | 0.2057 | 0.2064 | ||
PSZ-AC_5:5 | 0.9917 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9917 | 1.0000 | 1.0000 | 0.2057 | 0.2074 | ||
PSZ-AC_6:6 | 1.6601 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.6601 | 1.0000 | 1.0000 | 0.4115 | 0.2479 | ||
PSZ-AC_7:7 | 0.8646 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8646 | 1.0000 | 1.0000 | 0.2057 | 0.2379 | ||
PSZ-AC_8:8 | 0.8585 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8585 | 1.0000 | 1.0000 | 0.2057 | 0.2396 | ||
PSZ-AC_9:9 | 0.8588 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8588 | 1.0000 | 1.0000 | 0.2057 | 0.2395 | ||
PSZ-AC_10:10 | 0.9929 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9929 | 1.0000 | 1.0000 | 0.2057 | 0.2072 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.8292 | 1.8292 | 1.8292 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 0.9698 | 0.9698 | 0.9698 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.0025 | 1.0025 | 1.0025 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 0.9969 | 0.9969 | 0.9969 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 0.9917 | 0.9917 | 0.9917 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.6601 | 1.6601 | 1.6601 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.8646 | 0.8646 | 0.8646 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.8585 | 0.8585 | 0.8585 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.8588 | 0.8588 | 0.8588 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 0.9929 | 0.9929 | 0.9929 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.8292 | 1.8292 | 1.8292 | 1.8292 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 0.9698 | 0.9698 | 0.9698 | 0.9698 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0025 | 1.0025 | 1.0025 | 1.0025 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 0.9969 | 0.9969 | 0.9969 | 0.9969 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 0.9917 | 0.9917 | 0.9917 | 0.9917 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.6601 | 1.6601 | 1.6601 | 1.6601 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.8646 | 0.8646 | 0.8646 | 0.8646 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.8585 | 0.8585 | 0.8585 | 0.8585 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.8588 | 0.8588 | 0.8588 | 0.8588 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 0.9929 | 0.9929 | 0.9929 | 0.9929 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.8292 | 1.8292 | 1.8292 | 0.4115 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 0.9698 | 0.9698 | 0.9698 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 1.0025 | 1.0025 | 1.0025 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 0.9969 | 0.9969 | 0.9969 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 0.9917 | 0.9917 | 0.9917 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.6601 | 1.6601 | 1.6601 | 0.4115 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.8646 | 0.8646 | 0.8646 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.8585 | 0.8585 | 0.8585 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.8588 | 0.8588 | 0.8588 | 0.2057 | 1.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 0.9929 | 0.9929 | 0.9929 | 0.2057 | 0.9466 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.8292 | 1.8292 | 1.8292 | 1.8292 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 0.9698 | 0.9698 | 0.9698 | 0.9698 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 1.0025 | 1.0025 | 1.0025 | 1.0025 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 0.9969 | 0.9969 | 0.9969 | 0.9969 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 0.9917 | 0.9917 | 0.9917 | 0.9917 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.6601 | 1.6601 | 1.6601 | 1.6601 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.8646 | 0.8646 | 0.8646 | 0.8646 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.8585 | 0.8585 | 0.8585 | 0.8585 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.8588 | 0.8588 | 0.8588 | 0.8588 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 0.9929 | 0.9929 | 0.9929 | 0.9929 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:20:23
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Honolulu Intl Arpt HI USA TMY3 WMO#=911820 |
Total gross floor area [m2] | 2090.32 |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 430.64 | 51844.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 402.56 | 25772.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 59.45 | 5459.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.15 | 8059.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 89.40 | 8637.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 58.58 | 11780.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.15 | 1168.79 |
Natural Gas | 0.00 | 0.00 |
Additional | 0.00 | 0.00 |
Total | 128.15 | 1168.79 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 192.58 |
Space Heating | 0.00 |
Space Cooling | 206.02 |
Fans (All) | 42.77 |
Service Water Heating | 28.03 |
Receptacle Equipment | 61.31 |
Miscellaneous (All) | 559.14 |
Subtotal | 559.14 |
Natural Gas [MJ/m2] | |
Space Heating | 0.00 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 0.00 |
Subtotal | 0.00 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 34.44 |
Space Heating | 0.00 |
Space Cooling | 36.85 |
Fans (All) | 7.65 |
Service Water Heating | 5.01 |
Receptacle Equipment | 10.96 |
Miscellaneous | 5.09 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5122. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4868. | 8760. |
TYPE2_EQUIP_SCH | 3893. | 8760. |
TYPE3_EQUIP_SCH | 3584. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6570. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_NO_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_NO_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_NO_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1A
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_HI_HONOLULU
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.000 |
February | 0.000 | 0.000 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.000 |
Annual Sum or Average | 0.000 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.000 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.134653E+11 | 28787.71 | 12-JAN-08:62 | 22.88 | 18.16 | 0.751627E+09 | 899.03 | 20-JAN-13:00 | 25.00 | 16.56 |
February | 0.126046E+11 | 25740.05 | 13-FEB-08:62 | 23.98 | 19.24 | 0.678474E+09 | 899.02 | 11-FEB-13:20 | 24.63 | 16.25 |
March | 0.141612E+11 | 28587.68 | 19-MAR-07:02 | 21.88 | 17.44 | 0.744825E+09 | 898.98 | 26-MAR-16:19 | 25.60 | 19.02 |
April | 0.137141E+11 | 26871.76 | 07-APR-07:03 | 23.07 | 18.56 | 0.726267E+09 | 899.00 | 30-APR-16:10 | 27.02 | 19.32 |
May | 0.160498E+11 | 27737.87 | 22-MAY-07:02 | 23.77 | 19.39 | 0.747358E+09 | 898.99 | 21-MAY-17:00 | 27.20 | 21.04 |
June | 0.162340E+11 | 27438.73 | 04-JUN-07:02 | 24.67 | 20.27 | 0.722046E+09 | 899.00 | 04-JUN-17:00 | 26.70 | 19.95 |
July | 0.182297E+11 | 26134.77 | 08-JUL-07:02 | 25.37 | 20.63 | 0.753601E+09 | 898.97 | 30-JUL-16:19 | 29.23 | 21.06 |
August | 0.184982E+11 | 26563.05 | 24-AUG-07:02 | 23.27 | 19.94 | 0.743083E+09 | 898.96 | 06-AUG-17:00 | 26.70 | 21.73 |
September | 0.181196E+11 | 26534.42 | 19-SEP-07:02 | 22.98 | 20.28 | 0.728221E+09 | 898.93 | 03-SEP-16:30 | 32.25 | 23.55 |
October | 0.179308E+11 | 27306.80 | 26-OCT-07:03 | 21.23 | 19.48 | 0.751661E+09 | 898.96 | 29-OCT-17:00 | 26.70 | 21.42 |
November | 0.157957E+11 | 28125.33 | 15-NOV-08:62 | 23.98 | 18.53 | 0.726887E+09 | 898.96 | 12-NOV-17:30 | 25.85 | 20.51 |
December | 0.149028E+11 | 31155.44 | 24-DEC-08:62 | 22.38 | 16.70 | 0.755451E+09 | 898.98 | 22-DEC-13:30 | 25.90 | 17.24 |
Annual Sum or Average | 0.189706E+12 | 0.882950E+10 | ||||||||
Minimum of Months | 0.126046E+11 | 25740.05 | 21.23 | 16.70 | 0.678474E+09 | 898.93 | 24.63 | 16.25 | ||
Maximum of Months | 0.184982E+11 | 31155.44 | 25.37 | 20.63 | 0.755451E+09 | 899.03 | 32.25 | 23.55 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.744513E+10 | 16582.04 | 22-JAN-08:62 | 20.78 | 16.89 | 0.375817E+09 | 449.51 | 20-JAN-13:00 | 25.00 | 16.56 |
February | 0.683271E+10 | 15080.57 | 04-FEB-08:62 | 21.97 | 19.50 | 0.339246E+09 | 449.51 | 11-FEB-13:50 | 24.08 | 16.32 |
March | 0.762324E+10 | 16210.69 | 19-MAR-07:02 | 21.88 | 17.44 | 0.372428E+09 | 449.50 | 24-MAR-12:00 | 26.10 | 17.93 |
April | 0.737850E+10 | 15603.00 | 06-APR-07:03 | 22.48 | 16.83 | 0.363135E+09 | 449.50 | 30-APR-16:10 | 27.02 | 19.32 |
May | 0.853654E+10 | 15997.48 | 22-MAY-07:02 | 23.77 | 19.39 | 0.373681E+09 | 449.48 | 29-MAY-16:30 | 26.15 | 21.01 |
June | 0.853320E+10 | 15608.11 | 04-JUN-07:02 | 24.67 | 20.27 | 0.361024E+09 | 449.48 | 18-JUN-16:19 | 29.17 | 21.62 |
July | 0.950949E+10 | 14996.80 | 08-JUL-07:02 | 25.37 | 20.63 | 0.376801E+09 | 449.48 | 02-JUL-16:30 | 29.75 | 21.23 |
August | 0.961236E+10 | 15201.32 | 24-AUG-07:02 | 23.27 | 19.94 | 0.371542E+09 | 449.48 | 06-AUG-16:19 | 28.67 | 22.02 |
September | 0.932780E+10 | 15282.53 | 19-SEP-07:02 | 22.98 | 20.28 | 0.364110E+09 | 449.48 | 17-SEP-16:19 | 28.70 | 21.46 |
October | 0.950555E+10 | 15639.92 | 26-OCT-07:03 | 21.23 | 19.48 | 0.375830E+09 | 449.48 | 29-OCT-16:30 | 28.60 | 21.73 |
November | 0.843292E+10 | 16162.43 | 26-NOV-08:62 | 21.38 | 17.99 | 0.363444E+09 | 449.48 | 12-NOV-17:30 | 25.85 | 20.51 |
December | 0.811350E+10 | 17178.00 | 25-DEC-08:62 | 21.85 | 16.27 | 0.377728E+09 | 449.50 | 22-DEC-13:09 | 25.77 | 17.26 |
Annual Sum or Average | 0.100851E+12 | 0.441479E+10 | ||||||||
Minimum of Months | 0.683271E+10 | 14996.80 | 20.78 | 16.27 | 0.339246E+09 | 449.48 | 24.08 | 16.32 | ||
Maximum of Months | 0.961236E+10 | 17178.00 | 25.37 | 20.63 | 0.377728E+09 | 449.51 | 29.75 | 22.02 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.558624E+10 | 16063.10 | 22-JAN-08:62 | 20.78 | 16.89 | 0.224016E+09 | 449.50 | 21-JAN-13:09 | 25.68 | 17.07 |
February | 0.509926E+10 | 14256.70 | 13-FEB-07:03 | 23.40 | 18.65 | 0.203490E+09 | 449.51 | 11-FEB-13:30 | 24.45 | 16.28 |
March | 0.576024E+10 | 15090.95 | 19-MAR-07:02 | 21.88 | 17.44 | 0.230005E+09 | 449.47 | 18-MAR-12:09 | 27.70 | 19.76 |
April | 0.548730E+10 | 15416.50 | 06-APR-06:03 | 22.20 | 17.21 | 0.218953E+09 | 449.48 | 29-APR-12:00 | 27.20 | 18.09 |
May | 0.653239E+10 | 15231.40 | 31-MAY-06:03 | 22.38 | 17.90 | 0.227173E+09 | 449.45 | 27-MAY-12:09 | 29.60 | 20.63 |
June | 0.658143E+10 | 14509.34 | 04-JUN-07:02 | 24.67 | 20.27 | 0.222339E+09 | 449.43 | 03-JUN-12:09 | 28.25 | 20.83 |
July | 0.728054E+10 | 13827.76 | 04-JUL-07:02 | 25.37 | 20.83 | 0.224065E+09 | 449.46 | 08-JUL-12:09 | 31.20 | 21.97 |
August | 0.756292E+10 | 14131.21 | 24-AUG-06:02 | 21.38 | 19.31 | 0.230247E+09 | 449.43 | 05-AUG-12:00 | 30.00 | 21.62 |
September | 0.715187E+10 | 14154.50 | 19-SEP-06:02 | 22.30 | 20.24 | 0.219217E+09 | 449.39 | 16-SEP-12:50 | 27.20 | 23.19 |
October | 0.735021E+10 | 14330.09 | 19-OCT-06:03 | 19.40 | 17.64 | 0.224306E+09 | 449.38 | 28-OCT-12:09 | 30.18 | 22.21 |
November | 0.648968E+10 | 15338.32 | 09-NOV-07:03 | 18.77 | 17.50 | 0.216582E+09 | 449.42 | 25-NOV-13:09 | 28.30 | 22.38 |
December | 0.610733E+10 | 16814.83 | 25-DEC-08:62 | 21.85 | 16.27 | 0.223812E+09 | 449.48 | 23-DEC-13:09 | 25.77 | 17.78 |
Annual Sum or Average | 0.769894E+11 | 0.266421E+10 | ||||||||
Minimum of Months | 0.509926E+10 | 13827.76 | 18.77 | 16.27 | 0.203490E+09 | 449.38 | 24.45 | 16.28 | ||
Maximum of Months | 0.756292E+10 | 16814.83 | 25.37 | 20.83 | 0.230247E+09 | 449.51 | 31.20 | 23.19 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.555777E+10 | 15952.34 | 22-JAN-08:62 | 20.78 | 16.89 | 0.224012E+09 | 449.50 | 21-JAN-13:09 | 25.68 | 17.07 |
February | 0.507745E+10 | 14147.85 | 13-FEB-07:03 | 23.40 | 18.65 | 0.203486E+09 | 449.51 | 11-FEB-13:30 | 24.45 | 16.28 |
March | 0.574088E+10 | 15014.01 | 19-MAR-07:02 | 21.88 | 17.44 | 0.230001E+09 | 449.47 | 18-MAR-12:09 | 27.70 | 19.76 |
April | 0.546636E+10 | 15316.80 | 06-APR-06:03 | 22.20 | 17.21 | 0.218950E+09 | 449.48 | 29-APR-12:00 | 27.20 | 18.09 |
May | 0.653072E+10 | 15146.43 | 31-MAY-06:03 | 22.38 | 17.90 | 0.227171E+09 | 449.45 | 27-MAY-12:09 | 29.60 | 20.63 |
June | 0.658495E+10 | 14431.25 | 04-JUN-07:02 | 24.67 | 20.27 | 0.222337E+09 | 449.43 | 03-JUN-12:09 | 28.25 | 20.83 |
July | 0.730145E+10 | 13770.71 | 04-JUL-07:02 | 25.37 | 20.83 | 0.224064E+09 | 449.43 | 29-JUL-12:09 | 30.10 | 22.30 |
August | 0.758058E+10 | 14059.73 | 24-AUG-06:02 | 21.38 | 19.31 | 0.230246E+09 | 449.38 | 05-AUG-12:00 | 30.00 | 21.62 |
September | 0.718317E+10 | 14092.56 | 19-SEP-06:02 | 22.30 | 20.24 | 0.219217E+09 | 449.39 | 16-SEP-12:00 | 27.20 | 23.26 |
October | 0.737280E+10 | 14255.15 | 19-OCT-06:03 | 19.40 | 17.64 | 0.224306E+09 | 449.38 | 28-OCT-12:09 | 30.18 | 22.21 |
November | 0.648591E+10 | 15253.51 | 09-NOV-07:03 | 18.77 | 17.50 | 0.216579E+09 | 449.42 | 25-NOV-13:09 | 28.30 | 22.38 |
December | 0.609190E+10 | 16708.91 | 25-DEC-08:62 | 21.85 | 16.27 | 0.223809E+09 | 449.48 | 23-DEC-13:09 | 25.77 | 17.78 |
Annual Sum or Average | 0.769739E+11 | 0.266418E+10 | ||||||||
Minimum of Months | 0.507745E+10 | 13770.71 | 18.77 | 16.27 | 0.203486E+09 | 449.38 | 24.45 | 16.28 | ||
Maximum of Months | 0.758058E+10 | 16708.91 | 25.37 | 20.83 | 0.230246E+09 | 449.51 | 30.18 | 23.26 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.536197E+10 | 14672.86 | 22-JAN-08:62 | 20.78 | 16.89 | 0.223994E+09 | 449.50 | 21-JAN-13:09 | 25.68 | 17.07 |
February | 0.489842E+10 | 13301.45 | 13-FEB-07:03 | 23.40 | 18.65 | 0.203467E+09 | 449.47 | 11-FEB-13:50 | 24.08 | 16.32 |
March | 0.553765E+10 | 14888.49 | 19-MAR-07:02 | 21.88 | 17.44 | 0.229977E+09 | 449.47 | 18-MAR-12:09 | 27.70 | 19.76 |
April | 0.527396E+10 | 14261.92 | 06-APR-06:03 | 22.20 | 17.21 | 0.218932E+09 | 449.47 | 22-APR-12:30 | 27.80 | 19.73 |
May | 0.634566E+10 | 14577.49 | 23-MAY-06:03 | 19.55 | 17.86 | 0.227154E+09 | 449.45 | 27-MAY-12:09 | 29.60 | 20.63 |
June | 0.641045E+10 | 14285.72 | 04-JUN-07:02 | 24.67 | 20.27 | 0.222321E+09 | 449.43 | 03-JUN-12:09 | 28.25 | 20.83 |
July | 0.713522E+10 | 13629.97 | 04-JUL-07:02 | 25.37 | 20.83 | 0.224048E+09 | 449.46 | 08-JUL-12:09 | 31.20 | 21.97 |
August | 0.740451E+10 | 13920.22 | 24-AUG-06:02 | 21.38 | 19.31 | 0.230229E+09 | 449.43 | 05-AUG-12:00 | 30.00 | 21.62 |
September | 0.702014E+10 | 13956.75 | 19-SEP-06:02 | 22.30 | 20.24 | 0.219202E+09 | 449.39 | 30-SEP-12:20 | 27.57 | 23.54 |
October | 0.720007E+10 | 14109.45 | 19-OCT-06:03 | 19.40 | 17.64 | 0.224289E+09 | 449.39 | 28-OCT-12:09 | 30.18 | 22.21 |
November | 0.631455E+10 | 15116.94 | 09-NOV-07:03 | 18.77 | 17.50 | 0.216563E+09 | 449.42 | 25-NOV-13:09 | 28.30 | 22.38 |
December | 0.590685E+10 | 16470.63 | 24-DEC-08:62 | 22.38 | 16.70 | 0.223791E+09 | 449.48 | 23-DEC-13:30 | 25.90 | 17.77 |
Annual Sum or Average | 0.748094E+11 | 0.266397E+10 | ||||||||
Minimum of Months | 0.489842E+10 | 13301.45 | 18.77 | 16.70 | 0.203467E+09 | 449.39 | 24.08 | 16.32 | ||
Maximum of Months | 0.740451E+10 | 16470.63 | 25.37 | 20.83 | 0.230229E+09 | 449.50 | 31.20 | 23.54 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.861514E+10 | 26983.15 | 12-JAN-08:62 | 22.88 | 18.16 | 0.764903E+09 | 1198.63 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.788636E+10 | 23346.83 | 13-FEB-08:62 | 23.98 | 19.24 | 0.696477E+09 | 1198.57 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.894557E+10 | 25136.02 | 19-MAR-08:62 | 23.27 | 17.70 | 0.788895E+09 | 1198.54 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.849525E+10 | 24704.36 | 07-APR-07:03 | 23.07 | 18.56 | 0.751590E+09 | 1198.63 | 29-APR-14:50 | 27.30 | 18.14 |
May | 0.104536E+11 | 25972.15 | 31-MAY-07:03 | 23.58 | 18.09 | 0.777210E+09 | 1198.52 | 06-MAY-14:09 | 30.40 | 21.69 |
June | 0.106135E+11 | 23958.27 | 04-JUN-08:62 | 25.15 | 20.78 | 0.762352E+09 | 1198.47 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.118939E+11 | 24284.08 | 18-JUL-07:02 | 26.28 | 19.61 | 0.766999E+09 | 1198.39 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.123741E+11 | 24336.31 | 24-AUG-07:02 | 23.27 | 19.94 | 0.789283E+09 | 1198.36 | 05-AUG-14:09 | 31.60 | 22.39 |
September | 0.116946E+11 | 24701.50 | 19-SEP-07:02 | 22.98 | 20.28 | 0.752106E+09 | 1198.41 | 16-SEP-14:20 | 27.77 | 23.42 |
October | 0.120220E+11 | 24532.37 | 26-OCT-07:03 | 21.23 | 19.48 | 0.765547E+09 | 1198.34 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.104280E+11 | 26051.41 | 15-NOV-08:62 | 23.98 | 18.53 | 0.736991E+09 | 1198.49 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.961459E+10 | 28424.00 | 25-DEC-09:02 | 22.75 | 16.77 | 0.766310E+09 | 1198.54 | 23-DEC-15:39 | 24.87 | 17.34 |
Annual Sum or Average | 0.123037E+12 | 0.911866E+10 | ||||||||
Minimum of Months | 0.788636E+10 | 23346.83 | 21.23 | 16.77 | 0.696477E+09 | 1198.34 | 22.98 | 16.33 | ||
Maximum of Months | 0.123741E+11 | 28424.00 | 26.28 | 20.78 | 0.789283E+09 | 1198.63 | 31.60 | 23.42 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.441345E+10 | 12996.15 | 12-JAN-08:62 | 22.88 | 18.16 | 0.382443E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.404406E+10 | 11266.48 | 13-FEB-08:62 | 23.98 | 19.24 | 0.348230E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.459571E+10 | 12980.87 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394439E+09 | 599.27 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.437047E+10 | 12697.31 | 11-APR-07:03 | 22.48 | 19.66 | 0.375786E+09 | 599.31 | 29-APR-14:50 | 27.30 | 18.14 |
May | 0.541140E+10 | 12861.87 | 23-MAY-07:03 | 23.27 | 19.89 | 0.388594E+09 | 599.25 | 06-MAY-14:30 | 30.00 | 21.62 |
June | 0.549016E+10 | 12378.10 | 04-JUN-08:62 | 25.15 | 20.78 | 0.381164E+09 | 599.23 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.618296E+10 | 12564.18 | 18-JUL-07:02 | 26.28 | 19.61 | 0.383482E+09 | 599.19 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.644052E+10 | 12590.08 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394625E+09 | 599.17 | 05-AUG-14:09 | 31.60 | 22.39 |
September | 0.607317E+10 | 12797.48 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376034E+09 | 599.19 | 16-SEP-14:20 | 27.77 | 23.42 |
October | 0.625520E+10 | 12666.59 | 18-OCT-07:03 | 21.15 | 19.35 | 0.382757E+09 | 599.16 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.539000E+10 | 13483.45 | 15-NOV-08:62 | 23.98 | 18.53 | 0.368484E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.494957E+10 | 14688.71 | 25-DEC-09:02 | 22.75 | 16.77 | 0.383143E+09 | 599.27 | 23-DEC-15:39 | 24.87 | 17.34 |
Annual Sum or Average | 0.636167E+11 | 0.455918E+10 | ||||||||
Minimum of Months | 0.404406E+10 | 11266.48 | 21.15 | 16.77 | 0.348230E+09 | 599.16 | 22.98 | 16.33 | ||
Maximum of Months | 0.644052E+10 | 14688.71 | 26.28 | 20.78 | 0.394625E+09 | 599.31 | 31.60 | 23.42 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.436167E+10 | 12631.34 | 12-JAN-08:62 | 22.88 | 18.16 | 0.382439E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.399506E+10 | 11170.91 | 24-FEB-08:62 | 23.07 | 20.91 | 0.348226E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.454245E+10 | 12894.96 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394435E+09 | 599.27 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.432382E+10 | 12604.44 | 11-APR-07:03 | 22.48 | 19.66 | 0.375783E+09 | 599.31 | 29-APR-14:50 | 27.30 | 18.14 |
May | 0.536432E+10 | 12771.95 | 23-MAY-07:03 | 23.27 | 19.89 | 0.388591E+09 | 599.25 | 06-MAY-14:30 | 30.00 | 21.62 |
June | 0.544342E+10 | 12291.30 | 04-JUN-08:62 | 25.15 | 20.78 | 0.381161E+09 | 599.23 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.613781E+10 | 12477.09 | 18-JUL-07:02 | 26.28 | 19.61 | 0.383478E+09 | 599.19 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.639593E+10 | 12498.54 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394622E+09 | 599.17 | 05-AUG-14:09 | 31.60 | 22.39 |
September | 0.602854E+10 | 12702.38 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376031E+09 | 599.19 | 16-SEP-14:20 | 27.77 | 23.42 |
October | 0.620947E+10 | 12575.58 | 18-OCT-07:03 | 21.15 | 19.35 | 0.382754E+09 | 599.16 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.534042E+10 | 13383.87 | 15-NOV-08:62 | 23.98 | 18.53 | 0.368481E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.489812E+10 | 14590.30 | 25-DEC-09:02 | 22.75 | 16.77 | 0.383139E+09 | 599.27 | 23-DEC-15:39 | 24.87 | 17.34 |
Annual Sum or Average | 0.630410E+11 | 0.455914E+10 | ||||||||
Minimum of Months | 0.399506E+10 | 11170.91 | 21.15 | 16.77 | 0.348226E+09 | 599.16 | 22.98 | 16.33 | ||
Maximum of Months | 0.639593E+10 | 14590.30 | 26.28 | 20.91 | 0.394622E+09 | 599.31 | 31.60 | 23.42 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.429861E+10 | 12005.63 | 04-JAN-08:62 | 21.85 | 20.29 | 0.382434E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.392653E+10 | 10237.06 | 28-FEB-08:62 | 24.50 | 21.72 | 0.348220E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.447682E+10 | 12851.78 | 19-MAR-08:62 | 23.27 | 17.70 | 0.394425E+09 | 599.27 | 25-MAR-14:09 | 26.10 | 17.78 |
April | 0.428679E+10 | 12008.44 | 10-APR-07:03 | 23.27 | 19.37 | 0.375779E+09 | 599.31 | 29-APR-14:39 | 27.40 | 18.19 |
May | 0.536073E+10 | 12541.09 | 27-MAY-07:02 | 23.30 | 20.09 | 0.388589E+09 | 599.24 | 06-MAY-14:39 | 29.80 | 21.58 |
June | 0.544487E+10 | 12238.63 | 04-JUN-08:62 | 25.15 | 20.78 | 0.381160E+09 | 599.23 | 03-JUN-14:00 | 28.30 | 20.42 |
July | 0.615771E+10 | 12437.43 | 18-JUL-07:02 | 26.28 | 19.61 | 0.383477E+09 | 599.19 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.642758E+10 | 12475.19 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394623E+09 | 599.17 | 05-AUG-14:09 | 31.60 | 22.39 |
September | 0.604171E+10 | 12674.25 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376030E+09 | 599.19 | 16-SEP-14:20 | 27.77 | 23.42 |
October | 0.622353E+10 | 12457.30 | 17-OCT-07:02 | 23.48 | 19.40 | 0.382753E+09 | 599.16 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.531354E+10 | 13310.81 | 15-NOV-08:62 | 23.98 | 18.53 | 0.368478E+09 | 599.24 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.485131E+10 | 14424.67 | 24-DEC-09:02 | 23.50 | 17.22 | 0.383135E+09 | 599.27 | 23-DEC-15:39 | 24.87 | 17.34 |
Annual Sum or Average | 0.628097E+11 | 0.455910E+10 | ||||||||
Minimum of Months | 0.392653E+10 | 10237.06 | 21.85 | 17.22 | 0.348220E+09 | 599.16 | 22.98 | 16.33 | ||
Maximum of Months | 0.642758E+10 | 14424.67 | 26.28 | 21.72 | 0.394623E+09 | 599.31 | 31.60 | 23.42 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.499463E+10 | 12448.40 | 08-JAN-09:02 | 24.87 | 21.15 | 0.382462E+09 | 599.31 | 21-JAN-15:09 | 22.98 | 17.97 |
February | 0.443533E+10 | 10127.47 | 28-FEB-08:62 | 24.50 | 21.72 | 0.348243E+09 | 599.29 | 11-FEB-15:00 | 23.90 | 16.33 |
March | 0.515814E+10 | 12508.94 | 02-MAR-08:62 | 23.48 | 20.30 | 0.394444E+09 | 599.27 | 25-MAR-14:50 | 26.10 | 17.89 |
April | 0.518634E+10 | 13068.35 | 10-APR-07:03 | 23.27 | 19.37 | 0.375822E+09 | 599.32 | 29-APR-14:00 | 27.20 | 18.09 |
May | 0.662314E+10 | 13532.75 | 30-MAY-07:03 | 24.18 | 18.91 | 0.388638E+09 | 599.25 | 20-MAY-14:09 | 28.80 | 21.96 |
June | 0.670133E+10 | 13775.82 | 04-JUN-08:62 | 25.15 | 20.78 | 0.381203E+09 | 599.23 | 10-JUN-14:09 | 29.32 | 21.13 |
July | 0.759389E+10 | 13385.21 | 04-JUL-08:61 | 27.38 | 20.84 | 0.383548E+09 | 599.18 | 01-JUL-14:00 | 31.10 | 21.52 |
August | 0.800917E+10 | 13139.23 | 24-AUG-07:02 | 23.27 | 19.94 | 0.394679E+09 | 599.16 | 05-AUG-14:09 | 31.60 | 22.39 |
September | 0.723779E+10 | 13520.57 | 19-SEP-07:02 | 22.98 | 20.28 | 0.376098E+09 | 599.19 | 16-SEP-14:30 | 28.05 | 23.49 |
October | 0.758622E+10 | 13343.74 | 27-OCT-07:02 | 22.43 | 19.75 | 0.382817E+09 | 599.15 | 21-OCT-14:00 | 28.90 | 22.67 |
November | 0.622491E+10 | 14694.12 | 15-NOV-08:62 | 23.98 | 18.53 | 0.368514E+09 | 599.25 | 25-NOV-15:00 | 26.10 | 20.73 |
December | 0.562704E+10 | 16216.94 | 24-DEC-09:02 | 23.50 | 17.22 | 0.383168E+09 | 599.27 | 23-DEC-15:39 | 24.87 | 17.34 |
Annual Sum or Average | 0.753779E+11 | 0.455964E+10 | ||||||||
Minimum of Months | 0.443533E+10 | 10127.47 | 22.43 | 17.22 | 0.348243E+09 | 599.15 | 22.98 | 16.33 | ||
Maximum of Months | 0.800917E+10 | 16216.94 | 27.38 | 21.72 | 0.394679E+09 | 599.32 | 31.60 | 23.49 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3606819.59 | 980.41 | 12-JAN-08:05 | 22.88 |
February | 9799118.16 | 1616.32 | 18-FEB-08:06 | 24.60 |
March | 7726365.39 | 1197.24 | 15-MAR-07:05 | 23.68 |
April | 8066331.67 | 1408.29 | 25-APR-07:05 | 24.18 |
May | 23802249.95 | 1925.36 | 09-MAY-07:06 | 25.28 |
June | 29174462.45 | 2321.88 | 18-JUN-07:05 | 26.03 |
July | 27954461.71 | 2461.66 | 18-JUL-07:05 | 26.28 |
August | 27384884.27 | 2410.65 | 27-AUG-07:05 | 26.38 |
September | 19982889.81 | 2948.09 | 03-SEP-07:06 | 27.48 |
October | 15307335.49 | 2233.67 | 05-OCT-07:06 | 25.78 |
November | 17776114.94 | 2156.26 | 23-NOV-08:05 | 25.87 |
December | 9532925.25 | 2211.56 | 03-DEC-08:06 | 26.10 |
Annual Sum or Average | 0.200114E+09 | |||
Minimum of Months | 3606819.59 | 980.41 | 22.88 | |
Maximum of Months | 29174462.45 | 2948.09 | 27.48 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 2331816.43 | 581.12 | 12-JAN-08:05 | 22.88 |
February | 5782795.02 | 842.41 | 18-FEB-08:06 | 24.60 |
March | 4597089.24 | 714.13 | 15-MAR-07:05 | 23.68 |
April | 5089191.89 | 829.30 | 25-APR-07:05 | 24.18 |
May | 11901156.40 | 993.19 | 09-MAY-07:06 | 25.28 |
June | 14449009.85 | 1420.03 | 21-JUN-07:05 | 26.78 |
July | 14591199.37 | 1336.42 | 18-JUL-07:05 | 26.28 |
August | 14030266.48 | 1337.14 | 27-AUG-07:05 | 26.38 |
September | 12360986.11 | 1447.81 | 03-SEP-07:06 | 27.48 |
October | 9169544.30 | 1256.03 | 06-OCT-07:05 | 25.97 |
November | 11181075.33 | 1358.78 | 06-NOV-08:05 | 26.47 |
December | 5868475.41 | 1208.74 | 01-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.111353E+09 | |||
Minimum of Months | 2331816.43 | 581.12 | 22.88 | |
Maximum of Months | 14591199.37 | 1447.81 | 27.48 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3953119.78 | 876.84 | 29-JAN-17:03 | 26.83 |
February | 6290510.78 | 832.64 | 17-FEB-07:06 | 24.40 |
March | 8704756.64 | 943.94 | 12-MAR-16:03 | 27.12 |
April | 12281779.64 | 1168.52 | 09-APR-16:03 | 28.12 |
May | 34405929.08 | 1208.23 | 21-MAY-16:03 | 28.30 |
June | 46837269.54 | 1476.22 | 18-JUN-16:02 | 29.23 |
July | 67484236.52 | 1744.33 | 09-JUL-16:02 | 30.40 |
August | 65652181.88 | 2031.79 | 20-AUG-16:02 | 31.42 |
September | 63664132.74 | 2299.62 | 03-SEP-16:02 | 32.62 |
October | 51607976.68 | 2151.21 | 01-OCT-16:02 | 31.93 |
November | 22324814.61 | 1454.01 | 05-NOV-16:02 | 29.22 |
December | 12785873.97 | 1168.25 | 03-DEC-08:06 | 26.10 |
Annual Sum or Average | 0.395993E+09 | |||
Minimum of Months | 3953119.78 | 832.64 | 24.40 | |
Maximum of Months | 67484236.52 | 2299.62 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3921704.06 | 878.05 | 29-JAN-17:03 | 26.83 |
February | 6284119.13 | 825.94 | 17-FEB-07:06 | 24.40 |
March | 8688311.39 | 944.93 | 12-MAR-16:03 | 27.12 |
April | 12245936.81 | 1168.92 | 09-APR-16:03 | 28.12 |
May | 34325866.51 | 1208.09 | 21-MAY-16:03 | 28.30 |
June | 46529269.14 | 1475.65 | 18-JUN-16:02 | 29.23 |
July | 66949632.38 | 1743.79 | 09-JUL-16:02 | 30.40 |
August | 64645623.25 | 2030.93 | 20-AUG-16:02 | 31.42 |
September | 63364596.20 | 2298.40 | 03-SEP-16:02 | 32.62 |
October | 50894872.51 | 2150.55 | 01-OCT-16:02 | 31.93 |
November | 22103682.30 | 1453.27 | 05-NOV-16:02 | 29.22 |
December | 12759391.05 | 1157.87 | 03-DEC-08:06 | 26.10 |
Annual Sum or Average | 0.392713E+09 | |||
Minimum of Months | 3921704.06 | 825.94 | 24.40 | |
Maximum of Months | 66949632.38 | 2298.40 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3959711.24 | 884.00 | 29-JAN-17:03 | 26.83 |
February | 6653965.29 | 766.80 | 17-FEB-07:06 | 24.40 |
March | 9015015.10 | 950.99 | 12-MAR-16:03 | 27.12 |
April | 12780744.64 | 1174.67 | 09-APR-16:03 | 28.12 |
May | 34885736.25 | 1213.67 | 21-MAY-16:03 | 28.30 |
June | 47435863.67 | 1479.78 | 18-JUN-16:02 | 29.23 |
July | 68382920.60 | 1748.06 | 09-JUL-16:02 | 30.40 |
August | 67370793.20 | 2034.36 | 20-AUG-16:02 | 31.42 |
September | 64980125.25 | 2301.77 | 03-SEP-16:02 | 32.62 |
October | 53121711.79 | 2154.00 | 01-OCT-16:02 | 31.93 |
November | 22835246.82 | 1457.28 | 05-NOV-16:02 | 29.22 |
December | 13332038.93 | 1194.56 | 03-DEC-08:06 | 26.10 |
Annual Sum or Average | 0.404754E+09 | |||
Minimum of Months | 3959711.24 | 766.80 | 24.40 | |
Maximum of Months | 68382920.60 | 2301.77 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 10472072.27 | 1769.95 | 29-JAN-17:03 | 26.83 |
February | 18227605.36 | 1550.42 | 05-FEB-09:07 | 24.50 |
March | 20470250.55 | 1906.22 | 12-MAR-16:03 | 27.12 |
April | 28649476.90 | 2360.96 | 09-APR-16:03 | 28.12 |
May | 60306402.10 | 2441.77 | 21-MAY-16:03 | 28.30 |
June | 65003226.17 | 2954.16 | 18-JUN-16:02 | 29.23 |
July | 96577125.78 | 3502.82 | 09-JUL-16:02 | 30.40 |
August | 80611468.35 | 4060.88 | 20-AUG-16:02 | 31.42 |
September | 79876762.93 | 4609.89 | 03-SEP-16:02 | 32.62 |
October | 69046657.12 | 4305.33 | 01-OCT-16:02 | 31.93 |
November | 38754791.06 | 2917.42 | 05-NOV-16:02 | 29.22 |
December | 19317531.65 | 1991.04 | 01-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.587313E+09 | |||
Minimum of Months | 10472072.27 | 1550.42 | 24.50 | |
Maximum of Months | 96577125.78 | 4609.89 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 5268546.13 | 895.70 | 29-JAN-17:03 | 26.83 |
February | 9721374.43 | 796.49 | 05-FEB-09:07 | 24.50 |
March | 11177925.26 | 964.49 | 12-MAR-16:03 | 27.12 |
April | 15693769.64 | 1190.08 | 09-APR-16:03 | 28.12 |
May | 29945809.03 | 1229.95 | 21-MAY-16:03 | 28.30 |
June | 32647011.07 | 1486.98 | 18-JUN-16:02 | 29.23 |
July | 46822097.59 | 1759.10 | 09-JUL-16:02 | 30.40 |
August | 39968243.58 | 2038.78 | 20-AUG-16:02 | 31.42 |
September | 41313992.46 | 2310.87 | 03-SEP-16:02 | 32.62 |
October | 35435400.78 | 2159.84 | 01-OCT-16:02 | 31.93 |
November | 19545631.32 | 1466.94 | 05-NOV-16:02 | 29.22 |
December | 10255539.33 | 1056.30 | 01-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.297795E+09 | |||
Minimum of Months | 5268546.13 | 796.49 | 24.50 | |
Maximum of Months | 46822097.59 | 2310.87 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 5222746.53 | 896.45 | 29-JAN-17:03 | 26.83 |
February | 9848460.85 | 784.23 | 05-FEB-09:07 | 24.50 |
March | 11203534.83 | 965.25 | 12-MAR-16:03 | 27.12 |
April | 15741052.30 | 1190.88 | 09-APR-16:03 | 28.12 |
May | 29940843.96 | 1230.73 | 21-MAY-16:03 | 28.30 |
June | 32084389.77 | 1487.41 | 18-JUN-16:02 | 29.23 |
July | 46871319.51 | 1759.56 | 09-JUL-16:02 | 30.40 |
August | 39894081.75 | 2038.92 | 20-AUG-16:02 | 31.42 |
September | 41420491.00 | 2311.34 | 03-SEP-16:02 | 32.62 |
October | 35561267.27 | 2160.23 | 01-OCT-16:02 | 31.93 |
November | 19680953.53 | 1467.58 | 05-NOV-16:02 | 29.22 |
December | 10373504.74 | 1052.46 | 01-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.297843E+09 | |||
Minimum of Months | 5222746.53 | 784.23 | 24.50 | |
Maximum of Months | 46871319.51 | 2311.34 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 5003781.44 | 898.19 | 29-JAN-17:03 | 26.83 |
February | 9799095.09 | 768.32 | 26-FEB-17:03 | 26.32 |
March | 11352521.24 | 966.73 | 12-MAR-16:03 | 27.12 |
April | 15869759.33 | 1191.41 | 09-APR-16:03 | 28.12 |
May | 29588420.28 | 1230.56 | 21-MAY-16:03 | 28.30 |
June | 32349368.51 | 1487.14 | 18-JUN-16:02 | 29.23 |
July | 47058836.38 | 1758.86 | 09-JUL-16:02 | 30.40 |
August | 39342233.50 | 2037.76 | 20-AUG-16:02 | 31.42 |
September | 41803863.40 | 2310.16 | 03-SEP-16:02 | 32.62 |
October | 35455300.87 | 2159.96 | 01-OCT-16:02 | 31.93 |
November | 19403292.20 | 1467.51 | 05-NOV-16:02 | 29.22 |
December | 10890076.25 | 1072.58 | 01-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.297917E+09 | |||
Minimum of Months | 5003781.44 | 768.32 | 25.72 | |
Maximum of Months | 47058836.38 | 2310.16 | 32.62 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 4424057.94 | 899.84 | 29-JAN-17:03 | 26.83 |
February | 9525989.63 | 845.19 | 28-FEB-08:05 | 24.50 |
March | 11201156.66 | 957.70 | 12-MAR-16:03 | 27.12 |
April | 15004792.29 | 1176.14 | 09-APR-16:03 | 28.12 |
May | 25976647.90 | 1211.89 | 21-MAY-16:03 | 28.30 |
June | 26601498.90 | 1473.56 | 18-JUN-16:02 | 29.23 |
July | 39511831.92 | 1734.73 | 09-JUL-16:02 | 30.40 |
August | 34112112.68 | 2018.91 | 20-AUG-16:02 | 31.42 |
September | 38658401.41 | 2283.70 | 03-SEP-16:02 | 32.62 |
October | 33606906.55 | 2142.69 | 01-OCT-16:02 | 31.93 |
November | 16218335.54 | 1463.48 | 23-NOV-09:06 | 27.38 |
December | 10060272.75 | 1157.85 | 01-DEC-08:05 | 25.72 |
Annual Sum or Average | 0.264902E+09 | |||
Minimum of Months | 4424057.94 | 845.19 | 24.50 | |
Maximum of Months | 39511831.92 | 2283.70 | 32.62 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.813874E+10 | 5047.51 | 01-JAN-10:09 | 0.222596E+10 | 1343.25 | 01-JAN-10:09 |
February | 0.736333E+10 | 5047.51 | 01-FEB-10:09 | 0.201408E+10 | 1343.25 | 01-FEB-10:09 |
March | 0.815452E+10 | 5047.51 | 01-MAR-10:09 | 0.223053E+10 | 1343.25 | 01-MAR-10:09 |
April | 0.789616E+10 | 5047.51 | 01-APR-09:09 | 0.215990E+10 | 1343.25 | 01-APR-09:09 |
May | 0.813874E+10 | 5047.51 | 01-MAY-09:09 | 0.222596E+10 | 1343.25 | 01-MAY-09:09 |
June | 0.789593E+10 | 5047.51 | 01-JUN-09:09 | 0.215990E+10 | 1343.25 | 01-JUN-09:09 |
July | 0.815463E+10 | 5047.51 | 01-JUL-09:09 | 0.223053E+10 | 1343.25 | 01-JUL-09:09 |
August | 0.813874E+10 | 5047.51 | 01-AUG-09:09 | 0.222596E+10 | 1343.25 | 01-AUG-09:09 |
September | 0.791171E+10 | 5047.51 | 01-SEP-09:09 | 0.216447E+10 | 1343.25 | 01-SEP-09:09 |
October | 0.813885E+10 | 5047.51 | 01-OCT-09:09 | 0.222596E+10 | 1343.25 | 01-OCT-09:09 |
November | 0.786437E+10 | 5047.51 | 01-NOV-09:09 | 0.215077E+10 | 1343.25 | 01-NOV-09:09 |
December | 0.817030E+10 | 5047.51 | 01-DEC-10:09 | 0.223509E+10 | 1343.25 | 01-DEC-10:09 |
Annual Sum or Average | 0.959660E+11 | 0.262491E+11 | ||||
Minimum of Months | 0.736333E+10 | 5047.51 | 0.201408E+10 | 1343.25 | ||
Maximum of Months | 0.817030E+10 | 5047.51 | 0.223509E+10 | 1343.25 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.482855E+10 | 2998.49 | 01-JAN-10:09 | 0.111298E+10 | 671.63 | 01-JAN-10:09 |
February | 0.436853E+10 | 2998.49 | 01-FEB-10:09 | 0.100704E+10 | 671.63 | 01-FEB-10:09 |
March | 0.483792E+10 | 2998.49 | 01-MAR-10:09 | 0.111526E+10 | 671.63 | 01-MAR-10:09 |
April | 0.468466E+10 | 2998.49 | 01-APR-09:09 | 0.107995E+10 | 671.63 | 01-APR-09:09 |
May | 0.482855E+10 | 2998.49 | 01-MAY-09:09 | 0.111298E+10 | 671.63 | 01-MAY-09:09 |
June | 0.468451E+10 | 2998.49 | 01-JUN-09:09 | 0.107995E+10 | 671.63 | 01-JUN-09:09 |
July | 0.483800E+10 | 2998.49 | 01-JUL-09:09 | 0.111526E+10 | 671.63 | 01-JUL-09:09 |
August | 0.482855E+10 | 2998.49 | 01-AUG-09:09 | 0.111298E+10 | 671.63 | 01-AUG-09:09 |
September | 0.469388E+10 | 2998.49 | 01-SEP-09:09 | 0.108223E+10 | 671.63 | 01-SEP-09:09 |
October | 0.482862E+10 | 2998.49 | 01-OCT-09:09 | 0.111298E+10 | 671.63 | 01-OCT-09:09 |
November | 0.466576E+10 | 2998.49 | 01-NOV-09:09 | 0.107538E+10 | 671.63 | 01-NOV-09:09 |
December | 0.484730E+10 | 2998.49 | 01-DEC-10:09 | 0.111755E+10 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.569348E+11 | 0.131245E+11 | ||||
Minimum of Months | 0.436853E+10 | 2998.49 | 0.100704E+10 | 671.63 | ||
Maximum of Months | 0.484730E+10 | 2998.49 | 0.111755E+10 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.339205E+10 | 2736.71 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.307257E+10 | 2736.71 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.346979E+10 | 2736.71 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.329204E+10 | 2736.71 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.343092E+10 | 2736.71 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.335034E+10 | 2736.71 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.337262E+10 | 2736.71 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.346979E+10 | 2736.71 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.329204E+10 | 2736.71 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.339205E+10 | 2736.71 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.329204E+10 | 2736.71 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.337262E+10 | 2736.71 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.401989E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.307257E+10 | 2736.71 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.346979E+10 | 2736.71 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.339205E+10 | 2736.71 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.307257E+10 | 2736.71 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.346979E+10 | 2736.71 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.329204E+10 | 2736.71 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.343092E+10 | 2736.71 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.335034E+10 | 2736.71 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.337262E+10 | 2736.71 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.346979E+10 | 2736.71 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.329204E+10 | 2736.71 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.339205E+10 | 2736.71 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.329204E+10 | 2736.71 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.337262E+10 | 2736.71 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.401989E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.307257E+10 | 2736.71 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.346979E+10 | 2736.71 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.339205E+10 | 2736.71 | 01-JAN-10:09 | 0.879849E+09 | 671.63 | 01-JAN-10:09 |
February | 0.307257E+10 | 2736.71 | 01-FEB-09:09 | 0.796766E+09 | 671.63 | 01-FEB-09:09 |
March | 0.346979E+10 | 2736.71 | 01-MAR-09:09 | 0.898128E+09 | 671.63 | 01-MAR-09:09 |
April | 0.329204E+10 | 2736.71 | 01-APR-08:09 | 0.853677E+09 | 671.63 | 01-APR-08:09 |
May | 0.343092E+10 | 2736.71 | 01-MAY-08:09 | 0.888989E+09 | 671.63 | 01-MAY-08:09 |
June | 0.335034E+10 | 2736.71 | 01-JUN-08:09 | 0.867387E+09 | 671.63 | 01-JUN-08:09 |
July | 0.337262E+10 | 2736.71 | 01-JUL-08:09 | 0.875279E+09 | 671.63 | 01-JUL-08:09 |
August | 0.346979E+10 | 2736.71 | 01-AUG-08:09 | 0.898128E+09 | 671.63 | 01-AUG-08:09 |
September | 0.329204E+10 | 2736.71 | 01-SEP-08:09 | 0.853677E+09 | 671.63 | 01-SEP-08:09 |
October | 0.339205E+10 | 2736.71 | 01-OCT-09:09 | 0.879849E+09 | 671.63 | 01-OCT-09:09 |
November | 0.329204E+10 | 2736.71 | 01-NOV-08:09 | 0.853679E+09 | 671.63 | 01-NOV-08:09 |
December | 0.337262E+10 | 2736.71 | 01-DEC-09:09 | 0.875279E+09 | 671.63 | 01-DEC-09:09 |
Annual Sum or Average | 0.401989E+11 | 0.104207E+11 | ||||
Minimum of Months | 0.307257E+10 | 2736.71 | 0.796766E+09 | 671.63 | ||
Maximum of Months | 0.346979E+10 | 2736.71 | 0.898128E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.362835E+10 | 3172.05 | 01-JAN-11:09 | 0.161799E+10 | 1343.25 | 01-JAN-11:09 |
February | 0.328729E+10 | 3172.05 | 01-FEB-10:09 | 0.146554E+10 | 1343.25 | 01-FEB-10:09 |
March | 0.371755E+10 | 3172.05 | 01-MAR-10:09 | 0.165455E+10 | 1343.25 | 01-MAR-10:09 |
April | 0.352210E+10 | 3172.05 | 01-APR-09:09 | 0.157022E+10 | 1343.25 | 01-APR-09:09 |
May | 0.367295E+10 | 3172.05 | 01-MAY-09:09 | 0.163627E+10 | 1343.25 | 01-MAY-09:09 |
June | 0.358899E+10 | 3172.05 | 01-JUN-09:09 | 0.159764E+10 | 1343.25 | 01-JUN-09:09 |
July | 0.360605E+10 | 3172.05 | 01-JUL-09:09 | 0.160885E+10 | 1343.25 | 01-JUL-09:09 |
August | 0.371755E+10 | 3172.05 | 01-AUG-09:09 | 0.165455E+10 | 1343.25 | 01-AUG-09:09 |
September | 0.352210E+10 | 3172.05 | 01-SEP-09:09 | 0.157022E+10 | 1343.25 | 01-SEP-09:09 |
October | 0.362835E+10 | 3172.05 | 01-OCT-10:09 | 0.161799E+10 | 1343.25 | 01-OCT-10:09 |
November | 0.352210E+10 | 3172.05 | 01-NOV-09:09 | 0.157022E+10 | 1343.25 | 01-NOV-09:09 |
December | 0.360605E+10 | 3172.05 | 01-DEC-10:09 | 0.160885E+10 | 1343.25 | 01-DEC-10:09 |
Annual Sum or Average | 0.430194E+11 | 0.191729E+11 | ||||
Minimum of Months | 0.328729E+10 | 3172.05 | 0.146554E+10 | 1343.25 | ||
Maximum of Months | 0.371755E+10 | 3172.05 | 0.165455E+10 | 1343.25 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.181418E+10 | 1586.02 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.164365E+10 | 1586.02 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.185877E+10 | 1586.02 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.176105E+10 | 1586.02 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.183648E+10 | 1586.02 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.179450E+10 | 1586.02 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.180303E+10 | 1586.02 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.185877E+10 | 1586.02 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.176105E+10 | 1586.02 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.181418E+10 | 1586.02 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.176105E+10 | 1586.02 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.180303E+10 | 1586.02 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.215097E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.164365E+10 | 1586.02 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.185877E+10 | 1586.02 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.181418E+10 | 1586.02 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.164365E+10 | 1586.02 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.185877E+10 | 1586.02 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.176105E+10 | 1586.02 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.183648E+10 | 1586.02 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.179450E+10 | 1586.02 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.180303E+10 | 1586.02 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.185877E+10 | 1586.02 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.176105E+10 | 1586.02 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.181418E+10 | 1586.02 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.176105E+10 | 1586.02 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.180303E+10 | 1586.02 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.215097E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.164365E+10 | 1586.02 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.185877E+10 | 1586.02 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.181418E+10 | 1586.02 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.164365E+10 | 1586.02 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.185877E+10 | 1586.02 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.176105E+10 | 1586.02 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.183648E+10 | 1586.02 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.179450E+10 | 1586.02 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.180303E+10 | 1586.02 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.185877E+10 | 1586.02 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.176105E+10 | 1586.02 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.181418E+10 | 1586.02 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.176105E+10 | 1586.02 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.180303E+10 | 1586.02 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.215097E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.164365E+10 | 1586.02 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.185877E+10 | 1586.02 | 0.827277E+09 | 671.63 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.181418E+10 | 1586.02 | 01-JAN-11:09 | 0.808994E+09 | 671.63 | 01-JAN-11:09 |
February | 0.164365E+10 | 1586.02 | 01-FEB-10:09 | 0.732769E+09 | 671.63 | 01-FEB-10:09 |
March | 0.185877E+10 | 1586.02 | 01-MAR-10:09 | 0.827277E+09 | 671.63 | 01-MAR-10:09 |
April | 0.176105E+10 | 1586.02 | 01-APR-09:09 | 0.785109E+09 | 671.63 | 01-APR-09:09 |
May | 0.183648E+10 | 1586.02 | 01-MAY-09:09 | 0.818135E+09 | 671.63 | 01-MAY-09:09 |
June | 0.179450E+10 | 1586.02 | 01-JUN-09:09 | 0.798821E+09 | 671.63 | 01-JUN-09:09 |
July | 0.180303E+10 | 1586.02 | 01-JUL-09:09 | 0.804424E+09 | 671.63 | 01-JUL-09:09 |
August | 0.185877E+10 | 1586.02 | 01-AUG-09:09 | 0.827277E+09 | 671.63 | 01-AUG-09:09 |
September | 0.176105E+10 | 1586.02 | 01-SEP-09:09 | 0.785109E+09 | 671.63 | 01-SEP-09:09 |
October | 0.181418E+10 | 1586.02 | 01-OCT-10:09 | 0.808994E+09 | 671.63 | 01-OCT-10:09 |
November | 0.176105E+10 | 1586.02 | 01-NOV-09:09 | 0.785109E+09 | 671.63 | 01-NOV-09:09 |
December | 0.180303E+10 | 1586.02 | 01-DEC-10:09 | 0.804424E+09 | 671.63 | 01-DEC-10:09 |
Annual Sum or Average | 0.215097E+11 | 0.958644E+10 | ||||
Minimum of Months | 0.164365E+10 | 1586.02 | 0.732769E+09 | 671.63 | ||
Maximum of Months | 0.185877E+10 | 1586.02 | 0.827277E+09 | 671.63 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.813874E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.574150E+09 | 0.343004E+09 |
February | 0.163016E+10 | 0.736333E+10 | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.624247E+09 | 0.178354E+09 |
March | 0.178954E+10 | 0.815452E+10 | 0.223053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.947818E+09 | 0.181324E+09 |
April | 0.174484E+10 | 0.789616E+10 | 0.215990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103389E+10 | 0.153455E+09 |
May | 0.179537E+10 | 0.813874E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.162730E+10 | 84699292.69 |
June | 0.173447E+10 | 0.789593E+10 | 0.215990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159677E+10 | 62305527.82 |
July | 0.181028E+10 | 0.815463E+10 | 0.223053E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220466E+10 | 45280621.32 |
August | 0.178501E+10 | 0.813874E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240668E+10 | 40320203.05 |
September | 0.174937E+10 | 0.791171E+10 | 0.216447E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199087E+10 | 30458571.75 |
October | 0.180574E+10 | 0.813885E+10 | 0.222596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210626E+10 | 50276452.28 |
November | 0.174613E+10 | 0.786437E+10 | 0.215077E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123663E+10 | 0.112139E+09 |
December | 0.181481E+10 | 0.817030E+10 | 0.223509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.800055E+09 | 0.167936E+09 |
Annual Sum or Average | 0.212115E+11 | 0.959660E+11 | 0.262491E+11 | 0.171493E+11 | 0.144955E+10 | ||||
Minimum of Months | 0.163016E+10 | 0.736333E+10 | 0.201408E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.574150E+09 | 30458571.75 |
Maximum of Months | 0.181481E+10 | 0.817030E+10 | 0.223509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240668E+10 | 0.343004E+09 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.482855E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.321535E+09 | 0.146496E+09 |
February | 0.815075E+09 | 0.436853E+10 | 0.100704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.349740E+09 | 68977138.83 |
March | 0.894769E+09 | 0.483792E+10 | 0.111526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.529160E+09 | 63547460.57 |
April | 0.872416E+09 | 0.468466E+10 | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576204E+09 | 52214261.04 |
May | 0.897684E+09 | 0.482855E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.905952E+09 | 26238018.06 |
June | 0.867232E+09 | 0.468451E+10 | 0.107995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.880927E+09 | 19156740.22 |
July | 0.905135E+09 | 0.483800E+10 | 0.111526E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121609E+10 | 13869907.93 |
August | 0.892501E+09 | 0.482855E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133108E+10 | 12152657.64 |
September | 0.874683E+09 | 0.469388E+10 | 0.108223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109725E+10 | 9041126.82 |
October | 0.902868E+09 | 0.482862E+10 | 0.111298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117334E+10 | 15663367.78 |
November | 0.873064E+09 | 0.466576E+10 | 0.107538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.683970E+09 | 37106276.92 |
December | 0.907403E+09 | 0.484730E+10 | 0.111755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.446457E+09 | 61189899.33 |
Annual Sum or Average | 0.106057E+11 | 0.569348E+11 | 0.131245E+11 | 0.951170E+10 | 0.525653E+09 | ||||
Minimum of Months | 0.815075E+09 | 0.436853E+10 | 0.100704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.321535E+09 | 9041126.82 |
Maximum of Months | 0.907403E+09 | 0.484730E+10 | 0.111755E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133108E+10 | 0.146496E+09 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.339205E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318163E+09 | 0.173995E+09 |
February | 0.487879E+09 | 0.307257E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344661E+09 | 90739128.63 |
March | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521266E+09 | 84754658.62 |
April | 0.524810E+09 | 0.329204E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566532E+09 | 76913313.21 |
May | 0.544247E+09 | 0.343092E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.890186E+09 | 40898374.34 |
June | 0.532585E+09 | 0.335034E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.862454E+09 | 31282425.70 |
July | 0.536472E+09 | 0.337262E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118562E+10 | 23327378.57 |
August | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130869E+10 | 18510989.29 |
September | 0.524810E+09 | 0.329204E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106906E+10 | 15526335.39 |
October | 0.537120E+09 | 0.339205E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114755E+10 | 23727793.89 |
November | 0.518979E+09 | 0.329204E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671088E+09 | 56253633.15 |
December | 0.536472E+09 | 0.337262E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442473E+09 | 88766823.52 |
Annual Sum or Average | 0.638324E+10 | 0.401989E+11 | 0.104207E+11 | 0.932775E+10 | 0.724696E+09 | ||||
Minimum of Months | 0.487879E+09 | 0.307257E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318163E+09 | 15526335.39 |
Maximum of Months | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130869E+10 | 0.173995E+09 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.339205E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318168E+09 | 0.173621E+09 |
February | 0.487879E+09 | 0.307257E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344664E+09 | 90541039.55 |
March | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521274E+09 | 84657610.13 |
April | 0.524810E+09 | 0.329204E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566545E+09 | 76736181.15 |
May | 0.544247E+09 | 0.343092E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.890172E+09 | 41098387.11 |
June | 0.532585E+09 | 0.335034E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.862417E+09 | 31758720.57 |
July | 0.536472E+09 | 0.337262E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118543E+10 | 24225693.30 |
August | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130856E+10 | 19201874.44 |
September | 0.524810E+09 | 0.329204E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106870E+10 | 16345309.87 |
October | 0.537120E+09 | 0.339205E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114743E+10 | 24234816.62 |
November | 0.518979E+09 | 0.329204E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671084E+09 | 56467627.48 |
December | 0.536472E+09 | 0.337262E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442476E+09 | 88671119.26 |
Annual Sum or Average | 0.638324E+10 | 0.401989E+11 | 0.104207E+11 | 0.932692E+10 | 0.727559E+09 | ||||
Minimum of Months | 0.487879E+09 | 0.307257E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318168E+09 | 16345309.87 |
Maximum of Months | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130856E+10 | 0.173621E+09 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.339205E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318184E+09 | 0.171344E+09 |
February | 0.487879E+09 | 0.307257E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344677E+09 | 88692394.50 |
March | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521321E+09 | 82538384.71 |
April | 0.524810E+09 | 0.329204E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.566628E+09 | 74390258.15 |
May | 0.544247E+09 | 0.343092E+10 | 0.888989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.890373E+09 | 39086065.82 |
June | 0.532585E+09 | 0.335034E+10 | 0.867387E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.862661E+09 | 29126721.20 |
July | 0.536472E+09 | 0.337262E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118594E+10 | 21457138.11 |
August | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130895E+10 | 16996448.87 |
September | 0.524810E+09 | 0.329204E+10 | 0.853677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106926E+10 | 14243778.80 |
October | 0.537120E+09 | 0.339205E+10 | 0.879849E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114785E+10 | 22705492.90 |
November | 0.518979E+09 | 0.329204E+10 | 0.853679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671180E+09 | 54094696.01 |
December | 0.536472E+09 | 0.337262E+10 | 0.875279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442507E+09 | 86226364.87 |
Annual Sum or Average | 0.638324E+10 | 0.401989E+11 | 0.104207E+11 | 0.932952E+10 | 0.700902E+09 | ||||
Minimum of Months | 0.487879E+09 | 0.307257E+10 | 0.796766E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318184E+09 | 14243778.80 |
Maximum of Months | 0.551374E+09 | 0.346979E+10 | 0.898128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130895E+10 | 0.171344E+09 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.362835E+10 | 0.161799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558511E+09 | 0.314032E+09 |
February | 0.167188E+10 | 0.328729E+10 | 0.146554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604972E+09 | 0.164320E+09 |
March | 0.189386E+10 | 0.371755E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.915733E+09 | 0.155362E+09 |
April | 0.180380E+10 | 0.352210E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.995702E+09 | 0.139852E+09 |
May | 0.186509E+10 | 0.367295E+10 | 0.163627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156490E+10 | 72245145.54 |
June | 0.182945E+10 | 0.358899E+10 | 0.159764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151744E+10 | 49663863.24 |
July | 0.183943E+10 | 0.360605E+10 | 0.160885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208655E+10 | 34804124.63 |
August | 0.189386E+10 | 0.371755E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230317E+10 | 27957362.58 |
September | 0.180380E+10 | 0.352210E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188322E+10 | 22829074.72 |
October | 0.183632E+10 | 0.362835E+10 | 0.161799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201758E+10 | 41625408.38 |
November | 0.176881E+10 | 0.352210E+10 | 0.157022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117919E+10 | 99125868.86 |
December | 0.183943E+10 | 0.360605E+10 | 0.160885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.776465E+09 | 0.160093E+09 |
Annual Sum or Average | 0.218821E+11 | 0.430194E+11 | 0.191729E+11 | 0.164034E+11 | 0.128191E+10 | ||||
Minimum of Months | 0.167188E+10 | 0.328729E+10 | 0.146554E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558511E+09 | 22829074.72 |
Maximum of Months | 0.189386E+10 | 0.371755E+10 | 0.165455E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230317E+10 | 0.314032E+09 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318296E+09 | 0.168452E+09 |
February | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344800E+09 | 86247463.71 |
March | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521704E+09 | 79530572.90 |
April | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.567131E+09 | 70993806.21 |
May | 0.932542E+09 | 0.183648E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.891341E+09 | 35388913.81 |
June | 0.914724E+09 | 0.179450E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863635E+09 | 23375827.53 |
July | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118785E+10 | 15939565.70 |
August | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131126E+10 | 12907098.81 |
September | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107209E+10 | 10340431.64 |
October | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114980E+10 | 20295844.77 |
November | 0.884402E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671068E+09 | 49532605.10 |
December | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442400E+09 | 82580714.10 |
Annual Sum or Average | 0.109410E+11 | 0.215097E+11 | 0.958644E+10 | 0.934137E+10 | 0.655584E+09 | ||||
Minimum of Months | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318296E+09 | 10340431.64 |
Maximum of Months | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131126E+10 | 0.168452E+09 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318303E+09 | 0.167886E+09 |
February | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344808E+09 | 85773528.73 |
March | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521727E+09 | 79025254.76 |
April | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.567160E+09 | 70481963.68 |
May | 0.932542E+09 | 0.183648E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.891413E+09 | 34996242.35 |
June | 0.914724E+09 | 0.179450E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863766E+09 | 22913261.25 |
July | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118809E+10 | 15527116.15 |
August | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131143E+10 | 12622027.73 |
September | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107234E+10 | 10048543.77 |
October | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114996E+10 | 20038699.00 |
November | 0.884402E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671123E+09 | 49001895.15 |
December | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442427E+09 | 81987318.29 |
Annual Sum or Average | 0.109410E+11 | 0.215097E+11 | 0.958644E+10 | 0.934255E+10 | 0.650302E+09 | ||||
Minimum of Months | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318303E+09 | 10048543.77 |
Maximum of Months | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131143E+10 | 0.167886E+09 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318308E+09 | 0.166408E+09 |
February | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344810E+09 | 84490407.24 |
March | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.521749E+09 | 77751338.67 |
April | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.567185E+09 | 69254309.95 |
May | 0.932542E+09 | 0.183648E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.891454E+09 | 34169135.87 |
June | 0.914724E+09 | 0.179450E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863885E+09 | 21899114.64 |
July | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118828E+10 | 14750838.65 |
August | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131152E+10 | 12135661.12 |
September | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107247E+10 | 9537835.66 |
October | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115004E+10 | 19621853.18 |
November | 0.884402E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.671187E+09 | 47783503.93 |
December | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442501E+09 | 80592192.60 |
Annual Sum or Average | 0.109410E+11 | 0.215097E+11 | 0.958644E+10 | 0.934339E+10 | 0.638394E+09 | ||||
Minimum of Months | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.318308E+09 | 9537835.66 |
Maximum of Months | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131152E+10 | 0.166408E+09 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.328113E+09 | 0.257891E+09 |
February | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.355118E+09 | 0.146218E+09 |
March | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.539891E+09 | 0.153162E+09 |
April | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.588249E+09 | 0.141097E+09 |
May | 0.932542E+09 | 0.183648E+10 | 0.818135E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.925234E+09 | 79531212.58 |
June | 0.914724E+09 | 0.179450E+10 | 0.798821E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.906100E+09 | 55968631.56 |
July | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124470E+10 | 41301011.81 |
August | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137100E+10 | 34687061.85 |
September | 0.901896E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.112476E+10 | 27239507.92 |
October | 0.918158E+09 | 0.181418E+10 | 0.808994E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119033E+10 | 47231322.05 |
November | 0.884402E+09 | 0.176105E+10 | 0.785109E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.702917E+09 | 0.100546E+09 |
December | 0.919713E+09 | 0.180303E+10 | 0.804424E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.457907E+09 | 0.149566E+09 |
Annual Sum or Average | 0.109410E+11 | 0.215097E+11 | 0.958644E+10 | 0.973432E+10 | 0.123444E+10 | ||||
Minimum of Months | 0.835938E+09 | 0.164365E+10 | 0.732769E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.328113E+09 | 27239507.92 |
Maximum of Months | 0.946926E+09 | 0.185877E+10 | 0.827277E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137100E+10 | 0.257891E+09 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 5047.51 | 01-JAN-10:09 | 1343.25 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2595.06 | 06-JAN-13:00 | 2205.21 | 25-JAN-12:10 |
February | 2159.72 | 03-FEB-13:09 | 5047.51 | 01-FEB-10:09 | 1343.25 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2357.68 | 25-FEB-13:00 | 1074.71 | 06-FEB-18:00 |
March | 2159.72 | 03-MAR-13:09 | 5047.51 | 01-MAR-10:09 | 1343.25 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2913.07 | 29-MAR-13:00 | 816.00 | 03-MAR-15:00 |
April | 2159.72 | 01-APR-12:09 | 5047.51 | 01-APR-09:09 | 1343.25 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2928.09 | 09-APR-14:00 | 825.53 | 11-APR-14:00 |
May | 2159.72 | 05-MAY-12:09 | 5047.51 | 01-MAY-09:09 | 1343.25 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3458.53 | 17-MAY-13:00 | 285.16 | 15-MAY-17:00 |
June | 2159.72 | 02-JUN-12:09 | 5047.51 | 01-JUN-09:09 | 1343.25 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3240.13 | 29-JUN-11:10 | 186.29 | 13-JUN-05:00 |
July | 2159.72 | 01-JUL-12:09 | 5047.51 | 01-JUL-09:09 | 1343.25 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3937.60 | 09-JUL-12:00 | 191.51 | 13-JUL-06:00 |
August | 2159.72 | 04-AUG-12:09 | 5047.51 | 01-AUG-09:09 | 1343.25 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4201.02 | 11-AUG-14:00 | 155.08 | 13-AUG-03:00 |
September | 2159.72 | 01-SEP-12:09 | 5047.51 | 01-SEP-09:09 | 1343.25 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4517.84 | 03-SEP-13:00 | 160.01 | 30-SEP-06:00 |
October | 2159.72 | 01-OCT-12:09 | 5047.51 | 01-OCT-09:09 | 1343.25 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4429.07 | 01-OCT-13:00 | 283.45 | 19-OCT-07:03 |
November | 2159.72 | 03-NOV-12:09 | 5047.51 | 01-NOV-09:09 | 1343.25 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3261.29 | 04-NOV-13:00 | 1082.42 | 25-NOV-18:00 |
December | 2159.72 | 01-DEC-13:09 | 5047.51 | 01-DEC-10:09 | 1343.25 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3178.58 | 13-DEC-14:00 | 1005.42 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 5047.51 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 2357.68 | 155.08 | |||||
Maximum of Months | 2159.72 | 5047.51 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4517.84 | 2205.21 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 2998.49 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1463.00 | 03-JAN-14:00 | 1242.68 | 25-JAN-12:10 |
February | 1079.86 | 03-FEB-13:09 | 2998.49 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.16 | 25-FEB-13:00 | 602.31 | 06-FEB-18:00 |
March | 1079.86 | 03-MAR-13:09 | 2998.49 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.09 | 29-MAR-13:00 | 457.95 | 03-MAR-15:00 |
April | 1079.86 | 01-APR-12:09 | 2998.49 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.96 | 09-APR-14:00 | 464.06 | 11-APR-14:00 |
May | 1079.86 | 05-MAY-12:09 | 2998.49 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.44 | 17-MAY-13:00 | 161.11 | 15-MAY-17:00 |
June | 1079.86 | 02-JUN-12:09 | 2998.49 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.51 | 29-JUN-11:20 | 57.02 | 13-JUN-05:00 |
July | 1079.86 | 01-JUL-12:09 | 2998.49 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.78 | 09-JUL-12:00 | 57.99 | 13-JUL-06:00 |
August | 1079.86 | 04-AUG-12:09 | 2998.49 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.40 | 11-AUG-14:00 | 73.29 | 26-AUG-07:03 |
September | 1079.86 | 01-SEP-12:09 | 2998.49 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.18 | 03-SEP-13:00 | 61.30 | 19-SEP-07:02 |
October | 1079.86 | 01-OCT-12:09 | 2998.49 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.21 | 01-OCT-13:00 | 154.39 | 19-OCT-07:03 |
November | 1079.86 | 03-NOV-12:09 | 2998.49 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.87 | 04-NOV-13:00 | 603.82 | 25-NOV-18:00 |
December | 1079.86 | 01-DEC-13:09 | 2998.49 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.16 | 13-DEC-14:00 | 568.94 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 2998.49 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.16 | 57.02 | |||||
Maximum of Months | 1079.86 | 2998.49 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.18 | 1242.68 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 2736.71 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1462.85 | 03-JAN-13:50 | 1242.69 | 25-JAN-12:10 |
February | 1079.86 | 04-FEB-13:09 | 2736.71 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.18 | 25-FEB-13:00 | 727.92 | 12-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 2736.71 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.02 | 29-MAR-13:00 | 660.20 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 2736.71 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.94 | 09-APR-14:00 | 464.09 | 11-APR-14:00 |
May | 1079.86 | 06-MAY-12:09 | 2736.71 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.51 | 17-MAY-13:00 | 547.94 | 14-MAY-17:00 |
June | 1079.86 | 03-JUN-12:09 | 2736.71 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.53 | 29-JUN-11:10 | 72.32 | 08-JUN-23:00 |
July | 1079.86 | 01-JUL-12:09 | 2736.71 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.77 | 09-JUL-12:00 | 70.87 | 22-JUL-18:10 |
August | 1079.86 | 05-AUG-12:09 | 2736.71 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.36 | 11-AUG-14:00 | 59.76 | 26-AUG-07:05 |
September | 1079.86 | 02-SEP-12:09 | 2736.71 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.12 | 03-SEP-13:00 | 66.73 | 30-SEP-18:10 |
October | 1079.86 | 07-OCT-12:09 | 2736.71 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.15 | 01-OCT-13:00 | 504.59 | 22-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 2736.71 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.85 | 04-NOV-13:00 | 705.51 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 2736.71 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.14 | 13-DEC-14:00 | 892.41 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 2736.71 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.18 | 59.76 | |||||
Maximum of Months | 1079.86 | 2736.71 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.12 | 1242.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 2736.71 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1462.98 | 03-JAN-14:00 | 1242.69 | 25-JAN-12:10 |
February | 1079.86 | 04-FEB-13:09 | 2736.71 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.19 | 25-FEB-13:00 | 723.69 | 12-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 2736.71 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.02 | 29-MAR-13:00 | 657.64 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 2736.71 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.94 | 09-APR-14:00 | 464.09 | 11-APR-14:00 |
May | 1079.86 | 06-MAY-12:09 | 2736.71 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.50 | 17-MAY-13:00 | 549.07 | 14-MAY-17:00 |
June | 1079.86 | 03-JUN-12:09 | 2736.71 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.52 | 29-JUN-11:10 | 72.32 | 03-JUN-19:00 |
July | 1079.86 | 01-JUL-12:09 | 2736.71 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.77 | 09-JUL-12:00 | 71.48 | 22-JUL-18:10 |
August | 1079.86 | 05-AUG-12:09 | 2736.71 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.36 | 11-AUG-14:00 | 60.55 | 06-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 2736.71 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.12 | 03-SEP-13:00 | 67.53 | 30-SEP-18:10 |
October | 1079.86 | 07-OCT-12:09 | 2736.71 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.15 | 01-OCT-13:00 | 506.03 | 22-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 2736.71 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.85 | 04-NOV-13:00 | 702.73 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 2736.71 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.14 | 13-DEC-14:00 | 888.96 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 2736.71 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.19 | 60.55 | |||||
Maximum of Months | 1079.86 | 2736.71 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.12 | 1242.69 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 2736.71 | 01-JAN-10:09 | 671.63 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1462.63 | 03-JAN-14:00 | 1242.69 | 25-JAN-12:10 |
February | 1079.86 | 04-FEB-13:09 | 2736.71 | 01-FEB-09:09 | 671.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.17 | 25-FEB-13:00 | 706.16 | 12-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 2736.71 | 01-MAR-09:09 | 671.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1629.99 | 29-MAR-13:00 | 641.47 | 05-MAR-18:00 |
April | 1079.86 | 01-APR-12:09 | 2736.71 | 01-APR-08:09 | 671.63 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.92 | 09-APR-14:00 | 464.10 | 11-APR-14:00 |
May | 1079.86 | 06-MAY-12:09 | 2736.71 | 01-MAY-08:09 | 671.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.53 | 17-MAY-13:00 | 534.75 | 14-MAY-17:00 |
June | 1079.86 | 03-JUN-12:09 | 2736.71 | 01-JUN-08:09 | 671.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.58 | 29-JUN-11:10 | 69.92 | 08-JUN-23:00 |
July | 1079.86 | 01-JUL-12:09 | 2736.71 | 01-JUL-08:09 | 671.63 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.76 | 09-JUL-12:00 | 67.04 | 22-JUL-18:10 |
August | 1079.86 | 05-AUG-12:09 | 2736.71 | 01-AUG-08:09 | 671.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.35 | 11-AUG-14:00 | 59.77 | 26-AUG-07:05 |
September | 1079.86 | 02-SEP-12:09 | 2736.71 | 01-SEP-08:09 | 671.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.11 | 03-SEP-13:00 | 62.70 | 30-SEP-18:10 |
October | 1079.86 | 07-OCT-12:09 | 2736.71 | 01-OCT-09:09 | 671.63 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.15 | 01-OCT-13:00 | 491.16 | 22-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 2736.71 | 01-NOV-08:09 | 671.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.84 | 04-NOV-13:00 | 686.35 | 26-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 2736.71 | 01-DEC-09:09 | 671.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.13 | 13-DEC-14:00 | 872.47 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 2736.71 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.17 | 59.77 | |||||
Maximum of Months | 1079.86 | 2736.71 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.11 | 1242.69 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 3172.05 | 01-JAN-11:09 | 1343.25 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2564.34 | 03-JAN-14:00 | 2178.51 | 25-JAN-12:10 |
February | 2879.63 | 04-FEB-15:09 | 3172.05 | 01-FEB-10:09 | 1343.25 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2334.53 | 25-FEB-13:00 | 1133.18 | 12-FEB-18:00 |
March | 2879.63 | 04-MAR-15:09 | 3172.05 | 01-MAR-10:09 | 1343.25 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2860.58 | 29-MAR-13:00 | 1030.37 | 05-MAR-18:00 |
April | 2879.63 | 01-APR-14:09 | 3172.05 | 01-APR-09:09 | 1343.25 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2871.58 | 09-APR-14:00 | 813.96 | 11-APR-14:00 |
May | 2879.63 | 06-MAY-14:09 | 3172.05 | 01-MAY-09:09 | 1343.25 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3383.03 | 17-MAY-13:00 | 864.85 | 14-MAY-17:00 |
June | 2879.63 | 03-JUN-14:09 | 3172.05 | 01-JUN-09:09 | 1343.25 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3164.94 | 29-JUN-11:10 | 129.17 | 08-JUN-23:00 |
July | 2879.63 | 01-JUL-14:09 | 3172.05 | 01-JUL-09:09 | 1343.25 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3871.65 | 09-JUL-12:00 | 104.47 | 13-JUL-06:00 |
August | 2879.63 | 05-AUG-14:09 | 3172.05 | 01-AUG-09:09 | 1343.25 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4130.64 | 11-AUG-14:00 | 162.91 | 06-AUG-07:10 |
September | 2879.63 | 02-SEP-14:09 | 3172.05 | 01-SEP-09:09 | 1343.25 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4406.47 | 03-SEP-13:00 | 115.50 | 10-SEP-07:02 |
October | 2879.63 | 07-OCT-14:09 | 3172.05 | 01-OCT-10:09 | 1343.25 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4354.83 | 01-OCT-13:00 | 782.32 | 22-OCT-17:00 |
November | 2879.63 | 04-NOV-14:09 | 3172.05 | 01-NOV-09:09 | 1343.25 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3176.92 | 04-NOV-13:00 | 1109.01 | 26-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 3172.05 | 01-DEC-10:09 | 1343.25 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3129.56 | 13-DEC-14:00 | 1424.27 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 3172.05 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 2334.53 | 104.47 | |||||
Maximum of Months | 2879.63 | 3172.05 | 1343.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4406.47 | 2178.51 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1586.02 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1463.03 | 03-JAN-14:00 | 1242.68 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 1586.02 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.23 | 25-FEB-13:00 | 630.71 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1586.02 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.09 | 29-MAR-13:00 | 570.52 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1586.02 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.99 | 09-APR-14:00 | 464.13 | 11-APR-14:00 |
May | 1439.81 | 06-MAY-14:09 | 1586.02 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.49 | 17-MAY-13:00 | 475.64 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 1586.02 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.86 | 29-JUN-11:10 | 62.88 | 08-JUN-23:00 |
July | 1439.81 | 01-JUL-14:09 | 1586.02 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.77 | 09-JUL-12:00 | 50.49 | 13-JUL-06:00 |
August | 1439.81 | 05-AUG-14:09 | 1586.02 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.38 | 11-AUG-14:00 | 86.66 | 06-AUG-07:10 |
September | 1439.81 | 02-SEP-14:09 | 1586.02 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.13 | 03-SEP-13:00 | 63.15 | 10-SEP-07:02 |
October | 1439.81 | 07-OCT-14:09 | 1586.02 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.17 | 01-OCT-13:00 | 427.92 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1586.02 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.87 | 04-NOV-13:00 | 612.96 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1586.02 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.19 | 13-DEC-14:00 | 794.85 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.23 | 50.49 | |||||
Maximum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.13 | 1242.68 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1586.02 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1463.03 | 03-JAN-14:00 | 1242.68 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 1586.02 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.23 | 25-FEB-13:00 | 625.15 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1586.02 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.09 | 29-MAR-13:00 | 565.86 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1586.02 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.99 | 09-APR-14:00 | 464.14 | 11-APR-14:00 |
May | 1439.81 | 06-MAY-14:09 | 1586.02 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.78 | 17-MAY-13:00 | 472.10 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 1586.02 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.86 | 29-JUN-11:10 | 62.45 | 08-JUN-23:00 |
July | 1439.81 | 01-JUL-14:09 | 1586.02 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.77 | 09-JUL-12:00 | 49.87 | 13-JUL-06:00 |
August | 1439.81 | 05-AUG-14:09 | 1586.02 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.38 | 11-AUG-14:00 | 85.60 | 06-AUG-07:10 |
September | 1439.81 | 02-SEP-14:09 | 1586.02 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.13 | 03-SEP-13:00 | 62.18 | 10-SEP-07:02 |
October | 1439.81 | 07-OCT-14:09 | 1586.02 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.17 | 01-OCT-13:00 | 424.67 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1586.02 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.87 | 04-NOV-13:00 | 608.52 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1586.02 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.19 | 13-DEC-14:00 | 789.90 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.23 | 49.87 | |||||
Maximum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.13 | 1242.68 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1586.02 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1463.03 | 03-JAN-14:00 | 1242.68 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 1586.02 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.23 | 25-FEB-13:00 | 614.75 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1586.02 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1630.08 | 29-MAR-13:00 | 560.40 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1586.02 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1635.99 | 09-APR-14:00 | 464.14 | 11-APR-14:00 |
May | 1439.81 | 06-MAY-14:09 | 1586.02 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1926.78 | 17-MAY-13:00 | 469.02 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 1586.02 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1801.84 | 29-JUN-11:10 | 61.69 | 08-JUN-23:00 |
July | 1439.81 | 01-JUL-14:09 | 1586.02 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2206.78 | 09-JUL-12:00 | 48.69 | 13-JUL-06:00 |
August | 1439.81 | 05-AUG-14:09 | 1586.02 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2354.38 | 11-AUG-14:00 | 83.23 | 06-AUG-07:03 |
September | 1439.81 | 02-SEP-14:09 | 1586.02 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.14 | 03-SEP-13:00 | 60.05 | 10-SEP-07:02 |
October | 1439.81 | 07-OCT-14:09 | 1586.02 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2482.17 | 01-OCT-13:00 | 421.98 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1586.02 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1807.87 | 04-NOV-13:00 | 603.90 | 25-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1586.02 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1784.19 | 13-DEC-14:00 | 784.31 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1332.23 | 48.69 | |||||
Maximum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2508.14 | 1242.68 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 1586.02 | 01-JAN-11:09 | 671.63 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1494.08 | 06-JAN-13:00 | 1269.33 | 25-JAN-12:10 |
February | 1439.81 | 04-FEB-15:09 | 1586.02 | 01-FEB-10:09 | 671.63 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1355.54 | 25-FEB-13:00 | 653.69 | 12-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 1586.02 | 01-MAR-10:09 | 671.63 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1682.56 | 29-MAR-13:00 | 627.96 | 05-MAR-18:00 |
April | 1439.81 | 01-APR-14:09 | 1586.02 | 01-APR-09:09 | 671.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1692.49 | 09-APR-14:00 | 475.75 | 11-APR-14:00 |
May | 1439.81 | 06-MAY-14:09 | 1586.02 | 01-MAY-09:09 | 671.63 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2002.38 | 17-MAY-13:00 | 554.06 | 14-MAY-17:00 |
June | 1439.81 | 03-JUN-14:09 | 1586.02 | 01-JUN-09:09 | 671.63 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1877.51 | 29-JUN-11:10 | 152.07 | 08-JUN-23:00 |
July | 1439.81 | 01-JUL-14:09 | 1586.02 | 01-JUL-09:09 | 671.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2272.68 | 09-JUL-12:00 | 117.50 | 13-JUL-06:00 |
August | 1439.81 | 05-AUG-14:09 | 1586.02 | 01-AUG-09:09 | 671.63 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2424.63 | 11-AUG-14:00 | 120.15 | 06-AUG-07:10 |
September | 1439.81 | 02-SEP-14:09 | 1586.02 | 01-SEP-09:09 | 671.63 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2619.30 | 03-SEP-13:00 | 108.90 | 29-SEP-22:00 |
October | 1439.81 | 07-OCT-14:09 | 1586.02 | 01-OCT-10:09 | 671.63 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2556.23 | 01-OCT-13:00 | 510.40 | 22-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 1586.02 | 01-NOV-09:09 | 671.63 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1892.15 | 04-NOV-13:00 | 648.99 | 26-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 1586.02 | 01-DEC-10:09 | 671.63 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1833.19 | 13-DEC-14:00 | 828.45 | 31-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 1355.54 | 108.90 | |||||
Maximum of Months | 1439.81 | 1586.02 | 671.63 | 0.00 | 0.00 | 0.00 | 0.00 | 2619.30 | 1269.33 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 28787.71 | 12-JAN-08:62 | 719.91 | 300.00 | 298.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.85 |
February | 25740.05 | 13-FEB-08:62 | 719.91 | 300.00 | 298.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.57 |
March | 28587.68 | 19-MAR-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 195.70 |
April | 26871.76 | 07-APR-07:03 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.78 |
May | 27737.87 | 22-MAY-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.04 |
June | 27438.73 | 04-JUN-07:02 | 1079.86 | 450.00 | 447.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.50 |
July | 26134.77 | 08-JUL-07:02 | 0.00 | 375.00 | 368.20 | 0.00 | 0.00 | 0.00 | 0.00 | 48.82 | 0.00 |
August | 26563.05 | 24-AUG-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.36 |
September | 26534.42 | 19-SEP-07:02 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.96 |
October | 27306.80 | 26-OCT-07:03 | 719.91 | 300.00 | 298.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 195.75 |
November | 28125.33 | 15-NOV-08:62 | 1079.86 | 450.00 | 447.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.82 |
December | 31155.44 | 24-DEC-08:62 | 899.88 | 375.00 | 373.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.45 |
Annual Sum or Average | |||||||||||
Minimum of Months | 25740.05 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31155.44 | 1079.86 | 450.00 | 447.75 | 0.00 | 0.00 | 0.00 | 0.00 | 48.82 | 195.75 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16582.04 | 22-JAN-08:62 | 359.95 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 140.45 |
February | 15080.57 | 04-FEB-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.37 |
March | 16210.69 | 19-MAR-07:02 | 449.94 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.21 |
April | 15603.00 | 06-APR-07:03 | 359.95 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.97 |
May | 15997.48 | 22-MAY-07:02 | 449.94 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.32 |
June | 15608.11 | 04-JUN-07:02 | 539.93 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.69 |
July | 14996.80 | 08-JUL-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.69 | 0.00 |
August | 15201.32 | 24-AUG-07:02 | 449.94 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.37 |
September | 15282.53 | 19-SEP-07:02 | 449.94 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.30 |
October | 15639.92 | 26-OCT-07:03 | 359.95 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.24 |
November | 16162.43 | 26-NOV-08:62 | 359.95 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.25 |
December | 17178.00 | 25-DEC-08:62 | 359.95 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.89 |
Annual Sum or Average | |||||||||||
Minimum of Months | 14996.80 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 17178.00 | 539.93 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 26.69 | 140.45 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 16063.10 | 22-JAN-08:62 | 0.00 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.92 |
February | 14256.70 | 13-FEB-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.19 |
March | 15090.95 | 19-MAR-07:02 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 112.72 |
April | 15416.50 | 06-APR-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.29 |
May | 15231.40 | 31-MAY-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.54 |
June | 14509.34 | 04-JUN-07:02 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.42 |
July | 13827.76 | 04-JUL-07:02 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 7.27 | 0.00 |
August | 14131.21 | 24-AUG-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.18 |
September | 14154.50 | 19-SEP-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.11 |
October | 14330.09 | 19-OCT-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.02 |
November | 15338.32 | 09-NOV-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.14 |
December | 16814.83 | 25-DEC-08:62 | 0.00 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.33 |
Annual Sum or Average | |||||||||||
Minimum of Months | 13827.76 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16814.83 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 7.27 | 141.92 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 15952.34 | 22-JAN-08:62 | 0.00 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 141.10 |
February | 14147.85 | 13-FEB-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.02 |
March | 15014.01 | 19-MAR-07:02 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 113.42 |
April | 15316.80 | 06-APR-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.27 |
May | 15146.43 | 31-MAY-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.59 |
June | 14431.25 | 04-JUN-07:02 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.11 |
July | 13770.71 | 04-JUL-07:02 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 5.76 | 0.00 |
August | 14059.73 | 24-AUG-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.22 |
September | 14092.56 | 19-SEP-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.12 |
October | 14255.15 | 19-OCT-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.05 |
November | 15253.51 | 09-NOV-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.16 |
December | 16708.91 | 25-DEC-08:62 | 0.00 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 95.99 |
Annual Sum or Average | |||||||||||
Minimum of Months | 13770.71 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16708.91 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 5.76 | 141.10 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 14672.86 | 22-JAN-08:62 | 0.00 | 150.00 | 149.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139.78 |
February | 13301.45 | 13-FEB-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.58 |
March | 14888.49 | 19-MAR-07:02 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.94 |
April | 14261.92 | 06-APR-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.10 |
May | 14577.49 | 23-MAY-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.95 |
June | 14285.72 | 04-JUN-07:02 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.71 |
July | 13629.97 | 04-JUL-07:02 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 10.81 | 0.00 |
August | 13920.22 | 24-AUG-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.01 |
September | 13956.75 | 19-SEP-06:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 |
October | 14109.45 | 19-OCT-06:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.79 |
November | 15116.94 | 09-NOV-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.02 |
December | 16470.63 | 24-DEC-08:62 | 0.00 | 187.50 | 186.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.46 |
Annual Sum or Average | |||||||||||
Minimum of Months | 13301.45 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16470.63 | 0.00 | 225.00 | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 10.81 | 139.78 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 26983.15 | 12-JAN-08:62 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 89.27 |
February | 23346.83 | 13-FEB-08:62 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 2.22 | 0.00 |
March | 25136.02 | 19-MAR-08:62 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.78 |
April | 24704.36 | 07-APR-07:03 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.10 |
May | 25972.15 | 31-MAY-07:03 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.34 |
June | 23958.27 | 04-JUN-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 2.89 | 0.00 |
July | 24284.08 | 18-JUL-07:02 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 83.45 | 0.00 |
August | 24336.31 | 24-AUG-07:02 | 0.00 | 375.00 | 368.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.35 |
September | 24701.50 | 19-SEP-07:02 | 0.00 | 375.00 | 368.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.08 |
October | 24532.37 | 26-OCT-07:03 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 191.03 |
November | 26051.41 | 15-NOV-08:62 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.44 |
December | 28424.00 | 25-DEC-09:02 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.95 |
Annual Sum or Average | |||||||||||
Minimum of Months | 23346.83 | 0.00 | 300.00 | 294.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 28424.00 | 0.00 | 450.00 | 441.83 | 0.00 | 0.00 | 0.00 | 0.00 | 83.45 | 191.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12996.15 | 12-JAN-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.43 |
February | 11266.48 | 13-FEB-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 1.34 | 0.00 |
March | 12980.87 | 19-MAR-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.07 |
April | 12697.31 | 11-APR-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.78 |
May | 12861.87 | 23-MAY-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.64 |
June | 12378.10 | 04-JUN-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 4.77 | 0.00 |
July | 12564.18 | 18-JUL-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 50.06 | 0.00 |
August | 12590.08 | 24-AUG-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.67 |
September | 12797.48 | 19-SEP-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.06 |
October | 12666.59 | 18-OCT-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 111.03 |
November | 13483.45 | 15-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.34 |
December | 14688.71 | 25-DEC-09:02 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.24 |
Annual Sum or Average | |||||||||||
Minimum of Months | 11266.48 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14688.71 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 50.06 | 111.03 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12631.34 | 12-JAN-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.29 |
February | 11170.91 | 24-FEB-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.18 |
March | 12894.96 | 19-MAR-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.12 |
April | 12604.44 | 11-APR-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.10 |
May | 12771.95 | 23-MAY-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.10 |
June | 12291.30 | 04-JUN-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 5.64 | 0.00 |
July | 12477.09 | 18-JUL-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 50.86 | 0.00 |
August | 12498.54 | 24-AUG-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.89 |
September | 12702.38 | 19-SEP-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.30 |
October | 12575.58 | 18-OCT-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.29 |
November | 13383.87 | 15-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.16 |
December | 14590.30 | 25-DEC-09:02 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.20 |
Annual Sum or Average | |||||||||||
Minimum of Months | 11170.91 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14590.30 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 50.86 | 110.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12005.63 | 04-JAN-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.99 |
February | 10237.06 | 28-FEB-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 16.48 | 0.00 |
March | 12851.78 | 19-MAR-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.18 |
April | 12008.44 | 10-APR-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.41 |
May | 12541.09 | 27-MAY-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.30 |
June | 12238.63 | 04-JUN-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 8.95 | 0.00 |
July | 12437.43 | 18-JUL-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 53.48 | 0.00 |
August | 12475.19 | 24-AUG-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.14 |
September | 12674.25 | 19-SEP-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.28 |
October | 12457.30 | 17-OCT-07:02 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.52 |
November | 13310.81 | 15-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.67 |
December | 14424.67 | 24-DEC-09:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.96 |
Annual Sum or Average | |||||||||||
Minimum of Months | 10237.06 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14424.67 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 53.48 | 85.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12448.40 | 08-JAN-09:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.91 | 0.00 |
February | 10127.47 | 28-FEB-08:62 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 26.91 | 0.00 |
March | 12508.94 | 02-MAR-08:62 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.57 |
April | 13068.35 | 10-APR-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.68 |
May | 13532.75 | 30-MAY-07:03 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 7.59 | 0.00 |
June | 13775.82 | 04-JUN-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.57 |
July | 13385.21 | 04-JUL-08:61 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 93.25 | 0.00 |
August | 13139.23 | 24-AUG-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.07 |
September | 13520.57 | 19-SEP-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.71 |
October | 13343.74 | 27-OCT-07:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.94 |
November | 14694.12 | 15-NOV-08:62 | 0.00 | 225.00 | 220.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.66 |
December | 16216.94 | 24-DEC-09:02 | 0.00 | 187.50 | 184.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.05 |
Annual Sum or Average | |||||||||||
Minimum of Months | 10127.47 | 0.00 | 150.00 | 147.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16216.94 | 0.00 | 262.50 | 257.74 | 0.00 | 0.00 | 0.00 | 0.00 | 93.25 | 72.94 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.893019E+11 | 87891.61 | 04-JAN-13:50 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 0.840604E+11 | 86196.48 | 20-FEB-14:00 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 0.925355E+11 | 83355.98 | 13-MAR-14:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 0.880994E+11 | 78977.82 | 24-APR-13:30 | 0.00 | 0.00 | 01-APR-00:10 |
May | 0.987376E+11 | 84951.02 | 18-MAY-14:09 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 0.974706E+11 | 86038.16 | 29-JUN-13:30 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.105732E+12 | 92802.26 | 15-JUL-13:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.109120E+12 | 96084.93 | 19-AUG-14:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.104855E+12 | 99539.88 | 03-SEP-13:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.107226E+12 | 97141.77 | 11-OCT-12:39 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 0.968922E+11 | 90360.32 | 22-NOV-13:30 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 0.947602E+11 | 88730.03 | 06-DEC-13:50 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.116879E+13 | 0.00 | ||||
Minimum of Months | 0.840604E+11 | 78977.82 | 0.00 | 0.00 | ||
Maximum of Months | 0.109120E+12 | 99539.88 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.340285E+11 | 0.575607E+10 | 0.108325E+11 | 0.00 | 0.714777E+10 | 0.00 | 0.00 | 0.265195E+11 | 0.00 | 0.00 | 0.00 | 0.501759E+10 | 0.00 |
February | 0.308114E+11 | 0.495506E+10 | 0.980803E+10 | 0.00 | 0.656008E+10 | 0.00 | 0.00 | 0.273910E+11 | 0.00 | 0.00 | 0.00 | 0.453473E+10 | 0.00 |
March | 0.345545E+11 | 0.513047E+10 | 0.110038E+11 | 0.00 | 0.726797E+10 | 0.00 | 0.00 | 0.295511E+11 | 0.00 | 0.00 | 0.00 | 0.502766E+10 | 0.00 |
April | 0.330232E+11 | 0.459379E+10 | 0.105115E+11 | 0.00 | 0.690525E+10 | 0.00 | 0.00 | 0.282452E+11 | 0.00 | 0.00 | 0.00 | 0.482031E+10 | 0.00 |
May | 0.342789E+11 | 0.444263E+10 | 0.109147E+11 | 0.00 | 0.736365E+10 | 0.00 | 0.00 | 0.367778E+11 | 0.00 | 0.00 | 0.00 | 0.495986E+10 | 0.00 |
June | 0.333984E+11 | 0.415489E+10 | 0.106349E+11 | 0.00 | 0.721389E+10 | 0.00 | 0.00 | 0.372802E+11 | 0.00 | 0.00 | 0.00 | 0.478826E+10 | 0.00 |
July | 0.339286E+11 | 0.433454E+10 | 0.107982E+11 | 0.00 | 0.797291E+10 | 0.00 | 0.00 | 0.437885E+11 | 0.00 | 0.00 | 0.00 | 0.490890E+10 | 0.00 |
August | 0.345293E+11 | 0.461623E+10 | 0.109970E+11 | 0.00 | 0.830270E+10 | 0.00 | 0.00 | 0.457295E+11 | 0.00 | 0.00 | 0.00 | 0.494582E+10 | 0.00 |
September | 0.330480E+11 | 0.481324E+10 | 0.105184E+11 | 0.00 | 0.797478E+10 | 0.00 | 0.00 | 0.437171E+11 | 0.00 | 0.00 | 0.00 | 0.478335E+10 | 0.00 |
October | 0.340287E+11 | 0.533027E+10 | 0.108325E+11 | 0.00 | 0.816443E+10 | 0.00 | 0.00 | 0.439076E+11 | 0.00 | 0.00 | 0.00 | 0.496260E+10 | 0.00 |
November | 0.329725E+11 | 0.548470E+10 | 0.104978E+11 | 0.00 | 0.727375E+10 | 0.00 | 0.00 | 0.358364E+11 | 0.00 | 0.00 | 0.00 | 0.482692E+10 | 0.00 |
December | 0.339536E+11 | 0.584123E+10 | 0.108050E+11 | 0.00 | 0.725185E+10 | 0.00 | 0.00 | 0.319012E+11 | 0.00 | 0.00 | 0.00 | 0.500733E+10 | 0.00 |
Annual Sum or Average | 0.402556E+12 | 0.594531E+11 | 0.128154E+12 | 0.893990E+11 | 0.00 | 0.430645E+12 | 0.585833E+11 | ||||||
Minimum of Months | 0.308114E+11 | 0.415489E+10 | 0.980803E+10 | 0.00 | 0.656008E+10 | 0.00 | 0.00 | 0.265195E+11 | 0.00 | 0.00 | 0.00 | 0.453473E+10 | 0.00 |
Maximum of Months | 0.345545E+11 | 0.584123E+10 | 0.110038E+11 | 0.00 | 0.830270E+10 | 0.00 | 0.00 | 0.457295E+11 | 0.00 | 0.00 | 0.00 | 0.502766E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 25772.29 | 01-JAN-11:09 | 5459.01 | 01-JAN-06:10 | 8059.50 | 01-JAN-11:09 | 0.00 | 6229.92 | 02-JAN-08:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 25772.29 | 01-FEB-10:09 | 5459.01 | 01-FEB-06:10 | 8059.50 | 01-FEB-10:09 | 0.00 | 6601.84 | 19-FEB-13:00 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 25772.29 | 01-MAR-10:09 | 5459.01 | 01-MAR-06:10 | 8059.50 | 01-MAR-10:09 | 0.00 | 6267.78 | 13-MAR-14:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 25772.29 | 01-APR-09:09 | 5459.01 | 01-APR-05:10 | 8059.50 | 01-APR-09:09 | 0.00 | 6145.52 | 10-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 25772.29 | 01-MAY-09:09 | 5459.01 | 01-MAY-05:10 | 8059.50 | 01-MAY-09:09 | 0.00 | 6438.14 | 13-MAY-13:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 25772.29 | 01-JUN-09:09 | 5459.01 | 01-JUN-05:10 | 8059.50 | 01-JUN-09:09 | 0.00 | 6583.78 | 21-JUN-07:10 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 25772.29 | 01-JUL-09:09 | 5459.01 | 01-JUL-05:10 | 8059.50 | 01-JUL-09:09 | 0.00 | 7581.86 | 15-JUL-13:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 25772.29 | 01-AUG-09:09 | 5459.01 | 01-AUG-05:10 | 8059.50 | 01-AUG-09:09 | 0.00 | 8508.01 | 19-AUG-14:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 25772.29 | 01-SEP-09:09 | 5459.01 | 01-SEP-05:10 | 8059.50 | 01-SEP-09:09 | 0.00 | 8637.40 | 03-SEP-12:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 25772.29 | 01-OCT-10:09 | 5459.01 | 01-OCT-05:10 | 8059.50 | 01-OCT-10:09 | 0.00 | 8375.91 | 14-OCT-12:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 25772.29 | 01-NOV-09:09 | 5459.01 | 01-NOV-05:10 | 8059.50 | 01-NOV-09:09 | 0.00 | 7377.39 | 06-NOV-13:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 25772.29 | 01-DEC-10:09 | 5459.01 | 01-DEC-06:10 | 8059.50 | 01-DEC-10:09 | 0.00 | 6690.25 | 13-DEC-13:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 25772.29 | 5459.01 | 8059.50 | 0.00 | 6145.52 | 0.00 | 0.00 | |||||
Maximum of Months | 25772.29 | 5459.01 | 8059.50 | 0.00 | 8637.40 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 37594.24 | 04-JAN-13:00 | 0.00 | 0.00 | 0.00 | 11780.95 | 05-JAN-14:20 | 0.00 |
February | 39789.72 | 19-FEB-13:00 | 0.00 | 0.00 | 0.00 | 9640.48 | 25-FEB-16:49 | 0.00 |
March | 38315.80 | 13-MAR-14:09 | 0.00 | 0.00 | 0.00 | 8817.07 | 14-MAR-13:20 | 0.00 |
April | 35226.44 | 24-APR-13:00 | 0.00 | 0.00 | 0.00 | 9624.12 | 01-APR-17:00 | 0.00 |
May | 40297.44 | 13-MAY-13:00 | 0.00 | 0.00 | 0.00 | 9415.14 | 07-MAY-11:30 | 0.00 |
June | 39114.54 | 29-JUN-12:00 | 0.00 | 0.00 | 0.00 | 8905.45 | 26-JUN-19:10 | 0.00 |
July | 45956.26 | 15-JUL-13:00 | 0.00 | 0.00 | 0.00 | 8986.82 | 07-JUL-10:30 | 0.00 |
August | 50333.85 | 19-AUG-14:00 | 0.00 | 0.00 | 0.00 | 9570.53 | 04-AUG-13:00 | 0.00 |
September | 51844.12 | 03-SEP-12:00 | 0.00 | 0.00 | 0.00 | 7547.94 | 20-SEP-12:39 | 0.00 |
October | 49816.70 | 15-OCT-12:00 | 0.00 | 0.00 | 0.00 | 8118.13 | 04-OCT-18:40 | 0.00 |
November | 44242.54 | 06-NOV-13:00 | 0.00 | 0.00 | 0.00 | 9641.11 | 28-NOV-17:10 | 0.00 |
December | 41080.26 | 13-DEC-13:00 | 0.00 | 0.00 | 0.00 | 9641.62 | 06-DEC-17:49 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 35226.44 | 0.00 | 0.00 | 0.00 | 7547.94 | 0.00 | ||
Maximum of Months | 51844.12 | 0.00 | 0.00 | 0.00 | 11780.95 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 87891.61 | 04-JAN-13:50 | 25772.29 | 8059.50 | 0.00 | 0.00 | 6037.72 | 0.00 | 0.00 | 37288.23 | 0.00 |
February | 86196.48 | 20-FEB-14:00 | 25772.29 | 8059.50 | 0.00 | 0.00 | 6359.50 | 0.00 | 0.00 | 38487.54 | 0.00 |
March | 83355.98 | 13-MAR-14:09 | 25772.29 | 8059.50 | 0.00 | 0.00 | 6267.78 | 0.00 | 0.00 | 38315.80 | 0.00 |
April | 78977.82 | 24-APR-13:30 | 25772.29 | 8059.50 | 0.00 | 0.00 | 5363.43 | 0.00 | 0.00 | 34347.15 | 0.00 |
May | 84951.02 | 18-MAY-14:09 | 25772.29 | 8059.50 | 0.00 | 0.00 | 5954.42 | 0.00 | 0.00 | 37632.52 | 0.00 |
June | 86038.16 | 29-JUN-13:30 | 25772.29 | 8059.50 | 0.00 | 0.00 | 6112.24 | 0.00 | 0.00 | 38549.98 | 0.00 |
July | 92802.26 | 15-JUL-13:00 | 25772.29 | 8059.50 | 0.00 | 0.00 | 7581.86 | 0.00 | 0.00 | 45956.26 | 0.00 |
August | 96084.93 | 19-AUG-14:20 | 25772.29 | 8059.50 | 0.00 | 0.00 | 8392.63 | 0.00 | 0.00 | 49791.08 | 0.00 |
September | 99539.88 | 03-SEP-13:09 | 25772.29 | 8059.50 | 0.00 | 0.00 | 8604.34 | 0.00 | 0.00 | 51691.73 | 0.00 |
October | 97141.77 | 11-OCT-12:39 | 25772.29 | 8059.50 | 0.00 | 0.00 | 7872.55 | 0.00 | 0.00 | 47887.98 | 0.00 |
November | 90360.32 | 22-NOV-13:30 | 25772.29 | 8059.50 | 0.00 | 0.00 | 7295.63 | 0.00 | 0.00 | 43794.27 | 0.00 |
December | 88730.03 | 06-DEC-13:50 | 25772.29 | 8059.50 | 0.00 | 0.00 | 6605.48 | 0.00 | 0.00 | 39955.29 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 78977.82 | 25772.29 | 8059.50 | 0.00 | 0.00 | 5363.43 | 0.00 | 0.00 | 34347.15 | 0.00 | |
Maximum of Months | 99539.88 | 25772.29 | 8059.50 | 0.00 | 0.00 | 8604.34 | 0.00 | 0.00 | 51691.73 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.47 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.50 | 24.48 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.48 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.45 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.33 | 24.45 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.45 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.45 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.60 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.00 | 24.53 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.60 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.83 | 23.88 | 455.00 | 23.89 | 1.50 | 23.91 |
February | 55.17 | 23.86 | 427.17 | 23.89 | 52.83 | 23.88 |
March | 18.00 | 23.83 | 470.50 | 23.89 | 15.00 | 23.89 |
April | 0.00 | 0.00 | 462.33 | 23.89 | 0.00 | 0.00 |
May | 4.83 | 23.89 | 494.67 | 23.89 | 4.83 | 23.89 |
June | 2.00 | 23.97 | 480.00 | 23.89 | 2.00 | 23.97 |
July | 15.17 | 23.92 | 496.00 | 23.89 | 15.17 | 23.92 |
August | 10.17 | 23.94 | 496.00 | 23.89 | 10.17 | 23.94 |
September | 29.33 | 23.91 | 480.00 | 23.89 | 29.33 | 23.91 |
October | 7.50 | 23.90 | 495.50 | 23.89 | 7.50 | 23.90 |
November | 8.33 | 23.92 | 479.33 | 23.89 | 8.33 | 23.92 |
December | 5.83 | 23.91 | 484.33 | 23.89 | 5.83 | 23.91 |
Annual Sum or Average | 158.17 | 23.89 | 5720.83 | 23.89 | 152.50 | 23.90 |
Minimum of Months | 0.00 | 0.00 | 427.17 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 55.17 | 23.97 | 496.00 | 23.89 | 52.83 | 23.97 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 23.79 | 430.17 | 23.89 | 0.00 | 0.00 |
February | 31.50 | 23.87 | 411.00 | 23.89 | 29.67 | 23.89 |
March | 11.67 | 23.84 | 447.50 | 23.89 | 9.33 | 23.89 |
April | 0.00 | 0.00 | 434.83 | 23.89 | 0.00 | 0.00 |
May | 0.83 | 23.89 | 488.50 | 23.89 | 0.83 | 23.89 |
June | 0.00 | 0.00 | 479.33 | 23.89 | 0.00 | 0.00 |
July | 8.00 | 23.90 | 496.00 | 23.89 | 8.00 | 23.90 |
August | 0.00 | 0.00 | 496.00 | 23.89 | 0.00 | 0.00 |
September | 15.50 | 23.89 | 480.00 | 23.89 | 15.50 | 23.89 |
October | 1.50 | 23.89 | 494.50 | 23.89 | 1.50 | 23.89 |
November | 1.50 | 23.89 | 471.67 | 23.89 | 1.50 | 23.89 |
December | 2.83 | 23.91 | 467.33 | 23.89 | 2.83 | 23.91 |
Annual Sum or Average | 73.67 | 23.87 | 5596.83 | 23.89 | 69.17 | 23.89 |
Minimum of Months | 0.00 | 0.00 | 411.00 | 23.89 | 0.00 | 0.00 |
Maximum of Months | 31.50 | 23.91 | 496.00 | 23.89 | 29.67 | 23.91 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.17 | 24.67 | 356.83 | 24.00 | 3.17 | 24.67 |
February | 55.33 | 24.15 | 327.50 | 24.01 | 54.83 | 24.15 |
March | 16.17 | 24.10 | 367.50 | 24.02 | 15.83 | 24.12 |
April | 1.83 | 24.84 | 356.00 | 24.02 | 1.83 | 24.84 |
May | 7.83 | 24.76 | 375.00 | 24.04 | 7.83 | 24.76 |
June | 1.17 | 26.39 | 366.00 | 24.05 | 1.17 | 26.39 |
July | 15.17 | 24.88 | 369.00 | 24.07 | 15.17 | 24.88 |
August | 8.67 | 25.74 | 379.00 | 24.07 | 8.67 | 25.74 |
September | 31.33 | 24.80 | 360.00 | 24.08 | 31.33 | 24.80 |
October | 15.83 | 25.08 | 371.00 | 24.07 | 15.83 | 25.08 |
November | 6.33 | 24.96 | 360.00 | 24.03 | 6.33 | 24.96 |
December | 9.67 | 24.71 | 366.67 | 24.02 | 9.67 | 24.71 |
Annual Sum or Average | 172.50 | 24.61 | 4354.50 | 24.04 | 171.67 | 24.62 |
Minimum of Months | 1.17 | 24.10 | 327.50 | 24.00 | 1.17 | 24.12 |
Maximum of Months | 55.33 | 26.39 | 379.00 | 24.08 | 54.83 | 26.39 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.17 | 24.67 | 356.67 | 24.00 | 3.17 | 24.67 |
February | 55.83 | 24.14 | 327.33 | 24.01 | 55.17 | 24.15 |
March | 16.67 | 24.12 | 367.67 | 24.02 | 16.33 | 24.13 |
April | 1.83 | 24.83 | 355.83 | 24.02 | 1.83 | 24.83 |
May | 7.67 | 24.78 | 375.00 | 24.04 | 7.67 | 24.78 |
June | 1.17 | 26.39 | 366.00 | 24.05 | 1.17 | 26.39 |
July | 15.17 | 24.88 | 369.00 | 24.07 | 15.17 | 24.88 |
August | 9.00 | 25.68 | 379.00 | 24.07 | 9.00 | 25.68 |
September | 30.83 | 24.82 | 360.00 | 24.08 | 30.83 | 24.82 |
October | 15.67 | 25.10 | 371.00 | 24.07 | 15.67 | 25.10 |
November | 6.50 | 24.98 | 360.00 | 24.03 | 6.50 | 24.98 |
December | 9.83 | 24.69 | 366.67 | 24.02 | 9.83 | 24.69 |
Annual Sum or Average | 173.33 | 24.61 | 4354.17 | 24.04 | 172.33 | 24.62 |
Minimum of Months | 1.17 | 24.12 | 327.33 | 24.00 | 1.17 | 24.13 |
Maximum of Months | 55.83 | 26.39 | 379.00 | 24.08 | 55.17 | 26.39 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 4.00 | 24.49 | 354.50 | 24.00 | 4.00 | 24.49 |
February | 60.83 | 24.13 | 326.17 | 24.00 | 60.00 | 24.14 |
March | 19.17 | 24.08 | 365.00 | 24.01 | 18.17 | 24.11 |
April | 2.00 | 24.90 | 355.00 | 24.01 | 2.00 | 24.90 |
May | 8.17 | 24.69 | 375.00 | 24.04 | 8.17 | 24.69 |
June | 1.33 | 26.05 | 366.00 | 24.05 | 1.33 | 26.05 |
July | 16.67 | 24.77 | 369.00 | 24.07 | 16.67 | 24.77 |
August | 10.17 | 25.33 | 379.00 | 24.06 | 10.17 | 25.33 |
September | 32.67 | 24.75 | 360.00 | 24.08 | 32.67 | 24.75 |
October | 17.33 | 24.96 | 371.00 | 24.06 | 17.33 | 24.96 |
November | 7.83 | 24.77 | 360.00 | 24.03 | 7.83 | 24.77 |
December | 11.33 | 24.57 | 366.17 | 24.01 | 11.33 | 24.57 |
Annual Sum or Average | 191.50 | 24.53 | 4346.83 | 24.04 | 189.67 | 24.54 |
Minimum of Months | 1.33 | 24.08 | 326.17 | 24.00 | 1.33 | 24.11 |
Maximum of Months | 60.83 | 26.05 | 379.00 | 24.08 | 60.00 | 26.05 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 7.33 | 24.22 | 314.50 | 23.93 | 7.33 | 24.22 |
February | 70.83 | 24.00 | 292.17 | 23.93 | 70.67 | 24.00 |
March | 24.00 | 24.03 | 332.17 | 23.93 | 23.83 | 24.04 |
April | 5.00 | 24.22 | 321.00 | 23.94 | 5.00 | 24.22 |
May | 8.50 | 24.47 | 344.00 | 23.94 | 8.50 | 24.47 |
June | 1.00 | 26.00 | 336.00 | 23.94 | 1.00 | 26.00 |
July | 23.33 | 24.33 | 338.00 | 23.97 | 23.33 | 24.33 |
August | 12.67 | 24.71 | 348.00 | 23.95 | 12.67 | 24.71 |
September | 41.33 | 24.40 | 330.00 | 23.97 | 41.33 | 24.40 |
October | 11.83 | 25.20 | 340.00 | 23.96 | 11.83 | 25.20 |
November | 8.33 | 24.42 | 330.00 | 23.94 | 8.33 | 24.42 |
December | 15.00 | 24.39 | 329.83 | 23.93 | 15.00 | 24.39 |
Annual Sum or Average | 229.17 | 24.29 | 3955.67 | 23.95 | 228.83 | 24.29 |
Minimum of Months | 1.00 | 24.00 | 292.17 | 23.93 | 1.00 | 24.00 |
Maximum of Months | 70.83 | 26.00 | 348.00 | 23.97 | 70.67 | 26.00 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.33 | 24.17 | 304.00 | 23.93 | 8.33 | 24.17 |
February | 77.00 | 23.99 | 287.00 | 23.93 | 76.83 | 23.99 |
March | 25.83 | 24.03 | 324.17 | 23.93 | 25.33 | 24.04 |
April | 6.00 | 24.16 | 313.67 | 23.94 | 6.00 | 24.16 |
May | 8.50 | 24.46 | 343.33 | 23.94 | 8.50 | 24.46 |
June | 0.83 | 25.67 | 336.00 | 23.94 | 0.83 | 25.67 |
July | 25.33 | 24.28 | 338.00 | 23.97 | 25.33 | 24.28 |
August | 12.83 | 24.68 | 348.00 | 23.95 | 12.83 | 24.68 |
September | 43.83 | 24.35 | 330.00 | 23.97 | 43.83 | 24.35 |
October | 11.83 | 25.12 | 340.00 | 23.96 | 11.83 | 25.12 |
November | 10.17 | 24.32 | 330.00 | 23.94 | 10.17 | 24.32 |
December | 17.00 | 24.33 | 325.67 | 23.93 | 17.00 | 24.33 |
Annual Sum or Average | 247.50 | 24.24 | 3919.83 | 23.95 | 246.83 | 24.25 |
Minimum of Months | 0.83 | 23.99 | 287.00 | 23.93 | 0.83 | 23.99 |
Maximum of Months | 77.00 | 25.67 | 348.00 | 23.97 | 76.83 | 25.67 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.50 | 24.16 | 302.00 | 23.93 | 8.50 | 24.16 |
February | 80.17 | 23.98 | 286.17 | 23.93 | 80.00 | 23.98 |
March | 26.50 | 24.03 | 323.17 | 23.93 | 25.83 | 24.03 |
April | 6.17 | 24.15 | 311.83 | 23.94 | 6.17 | 24.15 |
May | 8.83 | 24.43 | 343.00 | 23.94 | 8.83 | 24.43 |
June | 1.00 | 25.37 | 336.00 | 23.94 | 1.00 | 25.37 |
July | 25.67 | 24.27 | 338.00 | 23.97 | 25.67 | 24.27 |
August | 13.17 | 24.66 | 348.00 | 23.95 | 13.17 | 24.66 |
September | 45.00 | 24.34 | 330.00 | 23.97 | 45.00 | 24.34 |
October | 12.83 | 25.02 | 340.00 | 23.96 | 12.83 | 25.02 |
November | 11.00 | 24.29 | 330.00 | 23.94 | 11.00 | 24.29 |
December | 17.17 | 24.32 | 325.00 | 23.93 | 17.17 | 24.32 |
Annual Sum or Average | 256.00 | 24.23 | 3913.17 | 23.94 | 255.17 | 24.23 |
Minimum of Months | 1.00 | 23.98 | 286.17 | 23.93 | 1.00 | 23.98 |
Maximum of Months | 80.17 | 25.37 | 348.00 | 23.97 | 80.00 | 25.37 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 9.50 | 24.13 | 302.83 | 23.93 | 9.50 | 24.13 |
February | 83.33 | 23.98 | 286.00 | 23.93 | 82.83 | 23.98 |
March | 28.17 | 24.01 | 322.83 | 23.93 | 27.17 | 24.02 |
April | 6.83 | 24.13 | 313.17 | 23.94 | 6.83 | 24.13 |
May | 9.33 | 24.40 | 343.33 | 23.94 | 9.33 | 24.40 |
June | 1.17 | 25.16 | 336.00 | 23.94 | 1.17 | 25.16 |
July | 26.00 | 24.29 | 338.00 | 23.97 | 26.00 | 24.29 |
August | 13.67 | 24.63 | 348.00 | 23.95 | 13.67 | 24.63 |
September | 44.67 | 24.34 | 330.00 | 23.97 | 44.67 | 24.34 |
October | 13.67 | 24.95 | 340.00 | 23.96 | 13.67 | 24.95 |
November | 12.67 | 24.23 | 330.00 | 23.94 | 12.67 | 24.23 |
December | 17.67 | 24.31 | 325.00 | 23.93 | 17.67 | 24.31 |
Annual Sum or Average | 266.67 | 24.22 | 3915.17 | 23.94 | 265.17 | 24.22 |
Minimum of Months | 1.17 | 23.98 | 286.00 | 23.93 | 1.17 | 23.98 |
Maximum of Months | 83.33 | 25.16 | 348.00 | 23.97 | 82.83 | 25.16 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.67 | 24.18 | 314.50 | 23.93 | 8.67 | 24.18 |
February | 73.33 | 23.99 | 291.50 | 23.93 | 72.50 | 24.00 |
March | 26.50 | 24.01 | 330.83 | 23.93 | 24.50 | 24.04 |
April | 4.50 | 24.29 | 323.50 | 23.94 | 4.50 | 24.29 |
May | 8.00 | 24.63 | 344.00 | 23.95 | 8.00 | 24.63 |
June | 2.33 | 25.33 | 336.00 | 23.95 | 2.33 | 25.33 |
July | 18.50 | 24.61 | 338.00 | 23.98 | 18.50 | 24.61 |
August | 7.50 | 25.68 | 348.00 | 23.95 | 7.50 | 25.68 |
September | 40.00 | 24.48 | 330.00 | 23.98 | 40.00 | 24.48 |
October | 12.83 | 25.26 | 340.00 | 23.97 | 12.83 | 25.26 |
November | 9.83 | 24.44 | 330.00 | 23.94 | 9.83 | 24.44 |
December | 15.00 | 24.42 | 328.67 | 23.94 | 15.00 | 24.42 |
Annual Sum or Average | 227.00 | 24.35 | 3955.00 | 23.95 | 224.17 | 24.36 |
Minimum of Months | 2.33 | 23.99 | 291.50 | 23.93 | 2.33 | 24.00 |
Maximum of Months | 73.33 | 25.68 | 348.00 | 23.98 | 72.50 | 25.68 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 23.89207 | 51.50946 | 0.52476 | 10.84918 |
February | 448.00000 | 23.88781 | 56.45547 | 0.56211 | 11.73403 |
March | 496.00000 | 23.88843 | 53.04018 | 0.53817 | 11.15797 |
April | 480.00000 | 23.89141 | 51.98917 | 0.53120 | 10.96330 |
May | 496.00000 | 23.89727 | 54.37258 | -0.2898 | 6.83273 |
June | 480.00000 | 23.90113 | 54.73159 | -0.2729 | 6.62104 |
July | 496.00000 | 23.90332 | 55.92775 | -0.2467 | 6.34571 |
August | 496.00000 | 23.90338 | 55.85097 | -0.2452 | 6.32942 |
September | 480.00000 | 23.90226 | 57.18738 | -0.2277 | 6.17425 |
October | 496.00000 | 23.89883 | 56.44815 | 0.60109 | 12.63102 |
November | 480.00000 | 23.90094 | 55.40644 | 0.58238 | 12.17244 |
December | 496.00000 | 23.89739 | 54.05932 | 0.55864 | 11.62534 |
Annual Sum or Average | 5840.00000 | 23.89708 | 54.73329 | 0.21589 | 9.43944 |
Minimum of Months | 448.00000 | 23.88781 | 51.50946 | -0.2898 | 6.17425 |
Maximum of Months | 496.00000 | 23.90338 | 57.18738 | 0.60109 | 12.63102 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 23.89345 | 49.49573 | 0.50756 | 10.47956 |
February | 448.00000 | 23.89058 | 54.04748 | 0.53867 | 11.20220 |
March | 496.00000 | 23.89176 | 51.11741 | 0.51681 | 10.68592 |
April | 480.00000 | 23.89246 | 50.14363 | 0.50922 | 10.49169 |
May | 496.00000 | 23.89857 | 52.59840 | -0.3198 | 7.22165 |
June | 480.00000 | 23.90186 | 53.18281 | -0.3055 | 7.02317 |
July | 496.00000 | 23.90367 | 54.36367 | -0.2835 | 6.76112 |
August | 496.00000 | 23.90360 | 54.36858 | -0.2831 | 6.75223 |
September | 480.00000 | 23.90242 | 55.74822 | -0.2683 | 6.59627 |
October | 496.00000 | 23.89955 | 54.58791 | 0.57372 | 11.96499 |
November | 480.00000 | 23.90156 | 53.49134 | 0.55749 | 11.58384 |
December | 496.00000 | 23.89869 | 52.01626 | 0.53762 | 11.14623 |
Annual Sum or Average | 5840.00000 | 23.89823 | 52.91862 | 0.18794 | 9.31472 |
Minimum of Months | 448.00000 | 23.89058 | 49.49573 | -0.3198 | 6.59627 |
Maximum of Months | 496.00000 | 23.90367 | 55.74822 | 0.57372 | 11.96499 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 23.97742 | 51.56382 | 0.54326 | 11.28831 |
February | 336.00000 | 23.98025 | 56.88429 | 0.57988 | 12.20202 |
March | 379.00000 | 23.98479 | 53.40303 | 0.55288 | 11.53769 |
April | 360.00000 | 23.98986 | 52.30201 | 0.54522 | 11.32925 |
May | 375.00000 | 24.00896 | 54.61475 | -0.2705 | 6.75370 |
June | 366.00000 | 24.01557 | 55.14831 | -0.2560 | 6.59762 |
July | 369.00000 | 24.03093 | 56.24683 | -0.2290 | 6.40232 |
August | 379.00000 | 24.02477 | 56.13063 | -0.2316 | 6.40888 |
September | 360.00000 | 24.03775 | 57.74476 | -0.2116 | 6.31783 |
October | 371.00000 | 24.02825 | 56.69593 | 0.62062 | 13.25624 |
November | 360.00000 | 24.00183 | 55.64165 | 0.59868 | 12.63306 |
December | 369.00000 | 23.98981 | 54.23427 | 0.57663 | 12.09424 |
Annual Sum or Average | 4395.00000 | 24.00601 | 55.03320 | 0.23144 | 9.71129 |
Minimum of Months | 336.00000 | 23.97742 | 51.56382 | -0.2705 | 6.31783 |
Maximum of Months | 379.00000 | 24.03775 | 57.74476 | 0.62062 | 13.25624 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 23.97663 | 51.61936 | 0.54253 | 11.27121 |
February | 336.00000 | 23.97935 | 56.93935 | 0.57924 | 12.18647 |
March | 379.00000 | 23.98392 | 53.44638 | 0.55235 | 11.52508 |
April | 360.00000 | 23.98924 | 52.34779 | 0.54471 | 11.31675 |
May | 375.00000 | 24.00861 | 54.63492 | -0.2705 | 6.75379 |
June | 366.00000 | 24.01528 | 55.16126 | -0.2559 | 6.59577 |
July | 369.00000 | 24.03085 | 56.23501 | -0.2282 | 6.39585 |
August | 379.00000 | 24.02465 | 56.12514 | -0.2309 | 6.40323 |
September | 360.00000 | 24.03778 | 57.71010 | -0.2105 | 6.31052 |
October | 371.00000 | 24.02818 | 56.67711 | 0.62115 | 13.27078 |
November | 360.00000 | 24.00144 | 55.66530 | 0.59859 | 12.63069 |
December | 369.00000 | 23.98927 | 54.27149 | 0.57626 | 12.08503 |
Annual Sum or Average | 4395.00000 | 24.00559 | 55.05155 | 0.23147 | 9.70503 |
Minimum of Months | 336.00000 | 23.97663 | 51.61936 | -0.2705 | 6.31052 |
Maximum of Months | 379.00000 | 24.03778 | 57.71010 | 0.62115 | 13.27078 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 23.97301 | 51.87144 | 0.53886 | 11.18439 |
February | 336.00000 | 23.97525 | 57.27007 | 0.57583 | 12.10116 |
March | 379.00000 | 23.97943 | 53.72350 | 0.54838 | 11.43050 |
April | 360.00000 | 23.98580 | 52.60340 | 0.54093 | 11.22579 |
May | 375.00000 | 24.00550 | 54.86545 | -0.2759 | 6.80375 |
June | 366.00000 | 24.01226 | 55.38364 | -0.2609 | 6.63777 |
July | 369.00000 | 24.02798 | 56.43178 | -0.2327 | 6.42646 |
August | 379.00000 | 24.02178 | 56.33140 | -0.2357 | 6.43651 |
September | 360.00000 | 24.03487 | 57.93082 | -0.2149 | 6.33533 |
October | 371.00000 | 24.02519 | 56.89727 | 0.61820 | 13.18661 |
November | 360.00000 | 23.99829 | 55.90111 | 0.59560 | 12.55005 |
December | 369.00000 | 23.98592 | 54.52470 | 0.57300 | 12.00179 |
Annual Sum or Average | 4395.00000 | 24.00227 | 55.29269 | 0.22746 | 9.67010 |
Minimum of Months | 336.00000 | 23.97301 | 51.87144 | -0.2759 | 6.33533 |
Maximum of Months | 379.00000 | 24.03487 | 57.93082 | 0.61820 | 13.18661 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.91739 | 53.02168 | 0.52134 | 10.77472 |
February | 308.00000 | 23.92195 | 58.57912 | 0.56065 | 11.70683 |
March | 348.00000 | 23.91845 | 54.89636 | 0.53070 | 10.99487 |
April | 330.00000 | 23.92819 | 53.71167 | 0.52291 | 10.79316 |
May | 344.00000 | 23.93123 | 55.92246 | -0.3058 | 7.08359 |
June | 336.00000 | 23.93140 | 56.53200 | -0.2909 | 6.88640 |
July | 338.00000 | 23.95269 | 57.51092 | -0.2589 | 6.59629 |
August | 348.00000 | 23.93551 | 57.33221 | -0.2656 | 6.63746 |
September | 330.00000 | 23.95281 | 59.02791 | -0.2410 | 6.47189 |
October | 340.00000 | 23.94714 | 57.81878 | 0.60048 | 12.68132 |
November | 330.00000 | 23.92811 | 57.04386 | 0.57811 | 12.07970 |
December | 338.00000 | 23.92344 | 55.70955 | 0.55544 | 11.55525 |
Annual Sum or Average | 4030.00000 | 23.93238 | 56.40516 | 0.20533 | 9.50034 |
Minimum of Months | 308.00000 | 23.91739 | 53.02168 | -0.3058 | 6.47189 |
Maximum of Months | 348.00000 | 23.95281 | 59.02791 | 0.60048 | 12.68132 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.91680 | 53.17051 | 0.50694 | 10.45995 |
February | 308.00000 | 23.92140 | 58.80951 | 0.54645 | 11.37425 |
March | 348.00000 | 23.91798 | 55.06443 | 0.51609 | 10.66976 |
April | 330.00000 | 23.92761 | 53.85225 | 0.50818 | 10.47178 |
May | 344.00000 | 23.93073 | 56.08728 | -0.3293 | 7.39273 |
June | 336.00000 | 23.93077 | 56.70432 | -0.3154 | 7.19149 |
July | 338.00000 | 23.95187 | 57.67688 | -0.2847 | 6.88403 |
August | 348.00000 | 23.93476 | 57.48136 | -0.2913 | 6.93123 |
September | 330.00000 | 23.95184 | 59.23218 | -0.2671 | 6.73921 |
October | 340.00000 | 23.94632 | 57.99173 | 0.58276 | 12.23507 |
November | 330.00000 | 23.92748 | 57.23185 | 0.56176 | 11.68283 |
December | 338.00000 | 23.92269 | 55.89480 | 0.54015 | 11.19895 |
Annual Sum or Average | 4030.00000 | 23.93171 | 56.57883 | 0.18587 | 9.41716 |
Minimum of Months | 308.00000 | 23.91680 | 53.17051 | -0.3293 | 6.73921 |
Maximum of Months | 348.00000 | 23.95187 | 59.23218 | 0.58276 | 12.23507 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.91648 | 53.24907 | 0.50548 | 10.42848 |
February | 308.00000 | 23.92104 | 58.91379 | 0.54503 | 11.34163 |
March | 348.00000 | 23.91759 | 55.14847 | 0.51458 | 10.63691 |
April | 330.00000 | 23.92733 | 53.92405 | 0.50678 | 10.44148 |
May | 344.00000 | 23.93050 | 56.15360 | -0.3314 | 7.42036 |
June | 336.00000 | 23.93055 | 56.77111 | -0.3174 | 7.21753 |
July | 338.00000 | 23.95158 | 57.73701 | -0.2867 | 6.90595 |
August | 348.00000 | 23.93456 | 57.53749 | -0.2933 | 6.95302 |
September | 330.00000 | 23.95156 | 59.29815 | -0.2690 | 6.75917 |
October | 340.00000 | 23.94605 | 58.05415 | 0.58147 | 12.20247 |
November | 330.00000 | 23.92721 | 57.30951 | 0.56039 | 11.64974 |
December | 338.00000 | 23.92235 | 55.97593 | 0.53875 | 11.16667 |
Annual Sum or Average | 4030.00000 | 23.93143 | 56.65152 | 0.18422 | 9.40841 |
Minimum of Months | 308.00000 | 23.91648 | 53.24907 | -0.3314 | 6.75917 |
Maximum of Months | 348.00000 | 23.95158 | 59.29815 | 0.58147 | 12.20247 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.91599 | 53.36924 | 0.50622 | 10.44486 |
February | 308.00000 | 23.92028 | 59.09190 | 0.54555 | 11.35534 |
March | 348.00000 | 23.91662 | 55.28494 | 0.51515 | 10.65093 |
April | 330.00000 | 23.92700 | 54.00360 | 0.50821 | 10.47208 |
May | 344.00000 | 23.93035 | 56.17088 | -0.3282 | 7.37675 |
June | 336.00000 | 23.93044 | 56.77934 | -0.3141 | 7.17361 |
July | 338.00000 | 23.95155 | 57.71301 | -0.2826 | 6.85832 |
August | 348.00000 | 23.93461 | 57.49785 | -0.2888 | 6.90034 |
September | 330.00000 | 23.95152 | 59.28941 | -0.2654 | 6.72019 |
October | 340.00000 | 23.94600 | 58.04505 | 0.58411 | 12.26826 |
November | 330.00000 | 23.92694 | 57.37238 | 0.56197 | 11.68734 |
December | 338.00000 | 23.92196 | 56.06993 | 0.53989 | 11.19329 |
Annual Sum or Average | 4030.00000 | 23.93113 | 56.70184 | 0.18651 | 9.40630 |
Minimum of Months | 308.00000 | 23.91599 | 53.36924 | -0.3282 | 6.72019 |
Maximum of Months | 348.00000 | 23.95155 | 59.28941 | 0.58411 | 12.26826 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 23.91843 | 52.84752 | 0.52900 | 10.95754 |
February | 308.00000 | 23.92245 | 58.70306 | 0.56475 | 11.82138 |
March | 348.00000 | 23.91802 | 54.96303 | 0.53837 | 11.18419 |
April | 330.00000 | 23.93108 | 53.24099 | 0.53777 | 11.13522 |
May | 344.00000 | 23.93470 | 55.06014 | -0.2739 | 6.72244 |
June | 336.00000 | 23.93445 | 55.66059 | -0.2600 | 6.55625 |
July | 338.00000 | 23.95782 | 56.52535 | -0.2219 | 6.26073 |
August | 348.00000 | 23.93954 | 56.18147 | -0.2242 | 6.25514 |
September | 330.00000 | 23.95770 | 58.34105 | -0.2111 | 6.23625 |
October | 340.00000 | 23.95173 | 56.86425 | 0.62359 | 13.30272 |
November | 330.00000 | 23.93022 | 56.66083 | 0.58926 | 12.36887 |
December | 338.00000 | 23.92482 | 55.41430 | 0.56362 | 11.76021 |
Annual Sum or Average | 4030.00000 | 23.93512 | 55.84596 | 0.22613 | 9.52337 |
Minimum of Months | 308.00000 | 23.91802 | 52.84752 | -0.2739 | 6.23625 |
Maximum of Months | 348.00000 | 23.95782 | 58.70306 | 0.62359 | 13.30272 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.219877E+11 | 0.544420E+10 | 492.83 | 0.148612E+11 | 0.712654E+10 | 0.00 | 1.00 | 02-JAN-08:62 | 0.00 | 01-JAN-00:05 | 46671.85 | 31-JAN-08:62 | 32218.30 | 12-JAN-08:62 | 20252.14 | 31-JAN-08:62 | 10116.34 | 02-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.237113E+11 | 0.569613E+10 | 444.40 | 0.143792E+11 | 0.933207E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 48328.51 | 17-FEB-08:62 | 29630.23 | 13-FEB-08:62 | 25395.26 | 17-FEB-08:62 | 10301.02 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.248590E+11 | 0.609615E+10 | 490.60 | 0.164744E+11 | 0.838459E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 47147.40 | 03-MAR-08:62 | 31055.38 | 19-MAR-07:02 | 22729.49 | 03-MAR-08:62 | 10087.79 | 15-MAR-07:03 | 0.00 | 01-MAR-00:05 |
April | 0.237795E+11 | 0.589224E+10 | 478.35 | 0.162439E+11 | 0.753562E+10 | 0.00 | 1.00 | 07-APR-07:03 | 0.00 | 01-APR-00:05 | 46189.52 | 25-APR-07:03 | 30391.65 | 10-APR-07:03 | 17668.78 | 24-APR-07:03 | 10156.59 | 25-APR-07:03 | 0.00 | 01-APR-00:05 |
May | 0.308337E+11 | 0.752482E+10 | 497.02 | 0.202993E+11 | 0.105343E+11 | 0.00 | 1.00 | 03-MAY-07:03 | 0.00 | 01-MAY-00:10 | 47445.44 | 10-MAY-07:02 | 31483.97 | 30-MAY-07:03 | 21696.47 | 10-MAY-07:02 | 10321.95 | 09-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.314871E+11 | 0.764252E+10 | 485.02 | 0.206071E+11 | 0.108800E+11 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 46987.81 | 14-JUN-07:02 | 30822.28 | 04-JUN-07:02 | 19718.55 | 14-JUN-07:02 | 10493.43 | 21-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.371945E+11 | 0.903438E+10 | 502.50 | 0.240054E+11 | 0.131891E+11 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 48293.10 | 20-JUL-07:02 | 30127.33 | 18-JUL-07:02 | 23758.19 | 20-JUL-07:03 | 10507.13 | 20-JUL-07:03 | 0.00 | 01-JUL-00:05 |
August | 0.378707E+11 | 0.926135E+10 | 499.69 | 0.246408E+11 | 0.132299E+11 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 47582.22 | 08-AUG-07:02 | 29651.70 | 07-AUG-07:02 | 21341.76 | 08-AUG-07:03 | 10461.93 | 27-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.380464E+11 | 0.913648E+10 | 486.90 | 0.237154E+11 | 0.143310E+11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 47978.37 | 30-SEP-07:02 | 29562.61 | 27-SEP-07:02 | 23527.91 | 30-SEP-07:03 | 10600.45 | 03-SEP-07:01 | 0.00 | 01-SEP-00:10 |
October | 0.367742E+11 | 0.893615E+10 | 497.55 | 0.234832E+11 | 0.132910E+11 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:05 | 47300.47 | 13-OCT-07:02 | 29874.99 | 26-OCT-07:03 | 20592.18 | 13-OCT-07:03 | 10421.68 | 07-OCT-07:02 | 0.00 | 01-OCT-00:05 |
November | 0.302526E+11 | 0.731583E+10 | 482.41 | 0.193376E+11 | 0.109150E+11 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 47389.93 | 01-NOV-07:02 | 31143.22 | 15-NOV-08:62 | 21226.10 | 01-NOV-07:03 | 10461.36 | 06-NOV-08:62 | 0.00 | 01-NOV-00:10 |
December | 0.271603E+11 | 0.658931E+10 | 498.46 | 0.174126E+11 | 0.974765E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-01:05 | 47652.94 | 03-DEC-08:61 | 33902.97 | 24-DEC-08:62 | 21560.89 | 03-DEC-08:04 | 10447.53 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.363957E+12 | 0.885696E+11 | 5855.73 | 0.235460E+12 | 0.128497E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.219877E+11 | 0.544420E+10 | 444.40 | 0.143792E+11 | 0.712654E+10 | 0.00 | 1.00 | 0.00 | 46189.52 | 29562.61 | 17668.78 | 10087.79 | 0.00 | |||||||
Maximum of Months | 0.380464E+11 | 0.926135E+10 | 502.50 | 0.246408E+11 | 0.143310E+11 | 0.00 | 1.00 | 0.00 | 48328.51 | 33902.97 | 25395.26 | 10600.45 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.118711E+11 | 0.291692E+10 | 493.66 | 0.831157E+10 | 0.355954E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 24054.39 | 31-JAN-08:62 | 18057.52 | 22-JAN-08:62 | 8393.84 | 31-JAN-08:62 | 5183.17 | 02-JAN-08:62 | 0.00 | 01-JAN-00:05 |
February | 0.124151E+11 | 0.297057E+10 | 445.76 | 0.784157E+10 | 0.457349E+10 | 0.00 | 1.00 | 04-FEB-08:62 | 0.00 | 01-FEB-00:05 | 24753.74 | 17-FEB-08:62 | 17029.39 | 13-FEB-08:62 | 10639.78 | 17-FEB-08:62 | 5302.25 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.129977E+11 | 0.317465E+10 | 493.27 | 0.889246E+10 | 0.410529E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 24184.87 | 03-MAR-08:62 | 17660.11 | 19-MAR-07:02 | 9211.43 | 03-MAR-08:62 | 5166.73 | 15-MAR-07:03 | 0.00 | 01-MAR-00:05 |
April | 0.123499E+11 | 0.304884E+10 | 478.85 | 0.870054E+10 | 0.364933E+10 | 0.00 | 1.00 | 07-APR-07:03 | 0.00 | 01-APR-00:05 | 23756.38 | 18-APR-07:03 | 17496.99 | 08-APR-07:03 | 7299.53 | 18-APR-07:03 | 5194.29 | 25-APR-07:03 | 0.00 | 01-APR-00:05 |
May | 0.156507E+11 | 0.380922E+10 | 497.85 | 0.106129E+11 | 0.503778E+10 | 0.00 | 1.00 | 01-MAY-07:03 | 0.00 | 01-MAY-00:10 | 24386.89 | 10-MAY-07:02 | 17908.71 | 22-MAY-07:02 | 9034.81 | 10-MAY-07:02 | 5297.10 | 09-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.157950E+11 | 0.382744E+10 | 485.18 | 0.106207E+11 | 0.517429E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 24263.36 | 14-JUN-07:02 | 17494.64 | 04-JUN-07:02 | 8512.00 | 14-JUN-07:02 | 5399.51 | 21-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.184370E+11 | 0.447861E+10 | 502.56 | 0.122321E+11 | 0.620493E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 24835.21 | 20-JUL-07:02 | 17215.09 | 08-JUL-07:02 | 10441.29 | 20-JUL-07:03 | 5424.02 | 20-JUL-07:02 | 0.00 | 01-JUL-00:05 |
August | 0.187701E+11 | 0.458719E+10 | 500.33 | 0.125306E+11 | 0.623952E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 24512.67 | 08-AUG-07:02 | 16956.32 | 07-AUG-07:02 | 9326.45 | 08-AUG-07:03 | 5380.33 | 08-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.186341E+11 | 0.447805E+10 | 486.76 | 0.119355E+11 | 0.669855E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 24656.54 | 30-SEP-07:02 | 16972.74 | 19-SEP-07:02 | 10118.55 | 30-SEP-07:03 | 5458.47 | 03-SEP-07:01 | 0.00 | 01-SEP-00:10 |
October | 0.184848E+11 | 0.448226E+10 | 497.39 | 0.121589E+11 | 0.632590E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:05 | 24350.84 | 13-OCT-07:02 | 17247.23 | 28-OCT-07:03 | 8853.08 | 13-OCT-07:03 | 5357.95 | 07-OCT-07:02 | 0.00 | 01-OCT-00:05 |
November | 0.154477E+11 | 0.372153E+10 | 481.61 | 0.101926E+11 | 0.525513E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 24429.52 | 01-NOV-07:02 | 17745.41 | 26-NOV-08:62 | 9216.34 | 01-NOV-07:03 | 5382.62 | 22-NOV-08:62 | 0.00 | 01-NOV-00:10 |
December | 0.141625E+11 | 0.341919E+10 | 498.91 | 0.941853E+10 | 0.474397E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-01:05 | 24617.80 | 03-DEC-08:61 | 18937.39 | 25-DEC-08:62 | 9577.92 | 03-DEC-08:03 | 5385.38 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.185016E+12 | 0.449145E+11 | 5862.12 | 0.123448E+12 | 0.615677E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.118711E+11 | 0.291692E+10 | 445.76 | 0.784157E+10 | 0.355954E+10 | 0.00 | 1.00 | 0.00 | 23756.38 | 16956.32 | 7299.53 | 5166.73 | 0.00 | |||||||
Maximum of Months | 0.187701E+11 | 0.458719E+10 | 502.56 | 0.125306E+11 | 0.669855E+10 | 0.00 | 1.00 | 0.00 | 24835.21 | 18937.39 | 10639.78 | 5458.47 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.927925E+10 | 0.225750E+10 | 360.02 | 0.635422E+10 | 0.292504E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 25718.35 | 02-JAN-07:02 | 17927.69 | 12-JAN-07:03 | 11780.52 | 01-JAN-08:62 | 5394.24 | 02-JAN-07:02 | 0.00 | 01-JAN-00:05 |
February | 0.978726E+10 | 0.231463E+10 | 324.24 | 0.600895E+10 | 0.377831E+10 | 0.00 | 1.00 | 04-FEB-07:03 | 0.00 | 01-FEB-00:05 | 26498.45 | 18-FEB-07:02 | 16391.95 | 13-FEB-07:03 | 14416.30 | 18-FEB-07:02 | 5490.58 | 17-FEB-07:02 | 0.00 | 01-FEB-00:05 |
March | 0.103027E+11 | 0.249492E+10 | 362.80 | 0.689701E+10 | 0.340573E+10 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:05 | 26114.33 | 13-MAR-06:02 | 16565.20 | 19-MAR-07:02 | 13148.37 | 13-MAR-06:02 | 5387.08 | 14-MAR-06:02 | 0.00 | 01-MAR-00:05 |
April | 0.969075E+10 | 0.237252E+10 | 349.56 | 0.668029E+10 | 0.301046E+10 | 0.00 | 1.00 | 06-APR-06:03 | 0.00 | 01-APR-00:05 | 25637.16 | 24-APR-06:03 | 17286.43 | 06-APR-06:03 | 11868.95 | 24-APR-06:03 | 5395.39 | 25-APR-06:03 | 0.00 | 01-APR-00:05 |
May | 0.126607E+11 | 0.304989E+10 | 367.23 | 0.842381E+10 | 0.423687E+10 | 0.00 | 1.00 | 01-MAY-06:03 | 0.00 | 01-MAY-00:10 | 26109.48 | 15-MAY-06:02 | 17137.42 | 31-MAY-06:03 | 13377.98 | 15-MAY-06:02 | 5476.62 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.129050E+11 | 0.308818E+10 | 361.58 | 0.847893E+10 | 0.442607E+10 | 0.00 | 1.00 | 01-JUN-06:03 | 0.00 | 01-JUN-00:10 | 25689.37 | 18-JUN-07:02 | 16432.40 | 04-JUN-07:02 | 11092.40 | 09-JUN-06:03 | 5573.09 | 21-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.149479E+11 | 0.358450E+10 | 365.47 | 0.971175E+10 | 0.523617E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 26486.69 | 23-JUL-07:01 | 15883.77 | 04-JUL-07:02 | 13509.70 | 23-JUL-07:04 | 5591.28 | 23-JUL-07:04 | 0.00 | 01-JUL-00:05 |
August | 0.155259E+11 | 0.375586E+10 | 374.73 | 0.101952E+11 | 0.533075E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 26238.11 | 20-AUG-07:02 | 15806.71 | 23-AUG-06:02 | 12769.02 | 20-AUG-07:03 | 5596.62 | 27-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.150564E+11 | 0.357102E+10 | 357.53 | 0.943275E+10 | 0.562368E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 26676.59 | 25-SEP-06:02 | 15743.54 | 29-SEP-06:02 | 14767.50 | 25-SEP-06:02 | 5663.38 | 03-SEP-07:03 | 0.00 | 01-SEP-00:10 |
October | 0.150070E+11 | 0.359850E+10 | 366.21 | 0.969862E+10 | 0.530838E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:05 | 26139.10 | 10-OCT-06:02 | 15649.71 | 28-OCT-06:02 | 13551.79 | 23-OCT-06:02 | 5543.56 | 07-OCT-06:02 | 0.00 | 01-OCT-00:05 |
November | 0.125561E+11 | 0.298973E+10 | 354.39 | 0.810388E+10 | 0.445220E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 25935.23 | 24-NOV-07:02 | 16855.59 | 15-NOV-07:02 | 12374.74 | 24-NOV-07:02 | 5557.44 | 23-NOV-08:62 | 0.00 | 01-NOV-00:10 |
December | 0.112340E+11 | 0.267684E+10 | 361.72 | 0.728248E+10 | 0.395152E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 26102.28 | 03-DEC-08:61 | 18645.77 | 25-DEC-08:62 | 12588.54 | 10-DEC-08:62 | 5580.48 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.148953E+12 | 0.357541E+11 | 4305.48 | 0.972678E+11 | 0.516852E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.927925E+10 | 0.225750E+10 | 324.24 | 0.600895E+10 | 0.292504E+10 | 0.00 | 1.00 | 0.00 | 25637.16 | 15649.71 | 11092.40 | 5387.08 | 0.00 | |||||||
Maximum of Months | 0.155259E+11 | 0.375586E+10 | 374.73 | 0.101952E+11 | 0.562368E+10 | 0.00 | 1.00 | 0.00 | 26676.59 | 18645.77 | 14767.50 | 5663.38 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.923330E+10 | 0.224519E+10 | 359.60 | 0.632227E+10 | 0.291103E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 25555.53 | 02-JAN-07:02 | 17804.65 | 12-JAN-07:03 | 11698.85 | 01-JAN-08:62 | 5359.82 | 02-JAN-07:02 | 0.00 | 01-JAN-00:05 |
February | 0.974998E+10 | 0.230440E+10 | 323.99 | 0.598426E+10 | 0.376572E+10 | 0.00 | 1.00 | 04-FEB-07:03 | 0.00 | 01-FEB-00:05 | 26330.03 | 18-FEB-07:02 | 16268.23 | 13-FEB-07:03 | 14337.75 | 18-FEB-07:02 | 5455.44 | 17-FEB-07:02 | 0.00 | 01-FEB-00:05 |
March | 0.102686E+11 | 0.248492E+10 | 361.91 | 0.687423E+10 | 0.339441E+10 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:05 | 25948.86 | 13-MAR-06:02 | 16466.27 | 19-MAR-07:02 | 13059.97 | 13-MAR-06:02 | 5352.74 | 14-MAR-06:02 | 0.00 | 01-MAR-00:05 |
April | 0.965473E+10 | 0.236204E+10 | 349.23 | 0.665578E+10 | 0.299894E+10 | 0.00 | 1.00 | 06-APR-06:03 | 0.00 | 01-APR-00:05 | 25472.54 | 24-APR-06:03 | 17167.96 | 06-APR-06:03 | 11800.29 | 24-APR-06:03 | 5361.01 | 25-APR-06:03 | 0.00 | 01-APR-00:05 |
May | 0.126502E+11 | 0.304450E+10 | 367.23 | 0.841939E+10 | 0.423082E+10 | 0.00 | 1.00 | 01-MAY-06:03 | 0.00 | 01-MAY-00:10 | 25945.19 | 15-MAY-06:02 | 17029.84 | 31-MAY-06:03 | 13282.28 | 15-MAY-06:02 | 5441.71 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.129022E+11 | 0.308457E+10 | 361.41 | 0.848034E+10 | 0.442189E+10 | 0.00 | 1.00 | 01-JUN-06:03 | 0.00 | 01-JUN-00:10 | 25528.75 | 18-JUN-07:02 | 16334.22 | 04-JUN-07:02 | 11029.43 | 09-JUN-06:03 | 5537.53 | 21-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.149702E+11 | 0.358702E+10 | 365.46 | 0.973258E+10 | 0.523767E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 26321.76 | 23-JUL-07:01 | 15802.45 | 04-JUL-07:02 | 13409.39 | 23-JUL-07:04 | 5555.47 | 23-JUL-07:04 | 0.00 | 01-JUL-00:05 |
August | 0.155441E+11 | 0.375745E+10 | 375.12 | 0.102131E+11 | 0.533101E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 26075.50 | 20-AUG-07:02 | 15718.03 | 23-AUG-06:02 | 12668.16 | 20-AUG-07:03 | 5560.82 | 27-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.150948E+11 | 0.357698E+10 | 357.41 | 0.946427E+10 | 0.563053E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 26512.59 | 25-SEP-06:02 | 15650.27 | 29-SEP-06:02 | 14635.67 | 25-SEP-06:02 | 5627.13 | 03-SEP-07:03 | 0.00 | 01-SEP-00:10 |
October | 0.150326E+11 | 0.360172E+10 | 366.32 | 0.972110E+10 | 0.531146E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:05 | 25977.92 | 10-OCT-06:02 | 15550.57 | 28-OCT-06:02 | 13454.96 | 23-OCT-06:02 | 5508.19 | 07-OCT-06:02 | 0.00 | 01-OCT-00:05 |
November | 0.125437E+11 | 0.298429E+10 | 354.28 | 0.809784E+10 | 0.444584E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 25772.93 | 24-NOV-07:02 | 16744.09 | 15-NOV-07:02 | 12334.03 | 24-NOV-07:04 | 5521.95 | 23-NOV-08:62 | 0.00 | 01-NOV-00:10 |
December | 0.112058E+11 | 0.266811E+10 | 361.79 | 0.726394E+10 | 0.394186E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 25937.25 | 03-DEC-08:61 | 18520.28 | 25-DEC-08:62 | 12511.87 | 10-DEC-08:62 | 5544.77 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.148850E+12 | 0.357012E+11 | 4303.75 | 0.972290E+11 | 0.516212E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.923330E+10 | 0.224519E+10 | 323.99 | 0.598426E+10 | 0.291103E+10 | 0.00 | 1.00 | 0.00 | 25472.54 | 15550.57 | 11029.43 | 5352.74 | 0.00 | |||||||
Maximum of Months | 0.155441E+11 | 0.375745E+10 | 375.12 | 0.102131E+11 | 0.563053E+10 | 0.00 | 1.00 | 0.00 | 26512.59 | 18520.28 | 14635.67 | 5627.13 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.897518E+10 | 0.218915E+10 | 358.29 | 0.612225E+10 | 0.285293E+10 | 0.00 | 1.00 | 01-JAN-08:62 | 0.00 | 01-JAN-00:05 | 25490.83 | 02-JAN-07:02 | 16110.76 | 12-JAN-07:03 | 11739.11 | 01-JAN-08:62 | 5347.78 | 02-JAN-07:02 | 0.00 | 01-JAN-00:05 |
February | 0.949746E+10 | 0.225042E+10 | 322.94 | 0.580069E+10 | 0.369677E+10 | 0.00 | 1.00 | 04-FEB-07:03 | 0.00 | 01-FEB-00:05 | 26267.19 | 18-FEB-07:02 | 15248.30 | 13-FEB-07:03 | 14422.88 | 18-FEB-07:02 | 5443.79 | 17-FEB-07:02 | 0.00 | 01-FEB-00:05 |
March | 0.999802E+10 | 0.242662E+10 | 360.86 | 0.666716E+10 | 0.333085E+10 | 0.00 | 1.00 | 01-MAR-07:03 | 0.00 | 01-MAR-00:05 | 25882.21 | 13-MAR-06:02 | 16346.96 | 19-MAR-07:02 | 13110.35 | 13-MAR-06:02 | 5340.72 | 14-MAR-06:02 | 0.00 | 01-MAR-00:05 |
April | 0.940224E+10 | 0.230768E+10 | 348.78 | 0.645951E+10 | 0.294274E+10 | 0.00 | 1.00 | 07-APR-06:03 | 0.00 | 01-APR-00:05 | 25406.72 | 24-APR-06:03 | 15909.74 | 07-APR-06:03 | 11857.99 | 24-APR-06:03 | 5349.07 | 25-APR-06:03 | 0.00 | 01-APR-00:05 |
May | 0.124082E+11 | 0.299288E+10 | 367.74 | 0.822887E+10 | 0.417938E+10 | 0.00 | 1.00 | 03-MAY-06:03 | 0.00 | 01-MAY-00:10 | 25880.12 | 15-MAY-06:02 | 16184.44 | 31-MAY-06:03 | 13322.16 | 15-MAY-06:02 | 5429.73 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.126726E+11 | 0.303586E+10 | 361.73 | 0.829969E+10 | 0.437291E+10 | 0.00 | 1.00 | 01-JUN-06:03 | 0.00 | 01-JUN-00:10 | 25460.63 | 18-JUN-07:02 | 16198.30 | 04-JUN-07:02 | 11110.37 | 09-JUN-06:03 | 5525.22 | 21-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.147498E+11 | 0.353754E+10 | 365.96 | 0.955681E+10 | 0.519303E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:05 | 26253.98 | 23-JUL-07:01 | 15672.00 | 04-JUL-07:02 | 13460.31 | 23-JUL-07:04 | 5543.64 | 23-JUL-07:04 | 0.00 | 01-JUL-00:05 |
August | 0.153094E+11 | 0.370413E+10 | 374.80 | 0.100259E+11 | 0.528349E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 26009.07 | 20-AUG-07:02 | 15584.20 | 23-AUG-06:02 | 12718.24 | 20-AUG-07:03 | 5548.86 | 27-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.148730E+11 | 0.352764E+10 | 357.62 | 0.929152E+10 | 0.558143E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 26446.99 | 25-SEP-06:02 | 15515.84 | 29-SEP-06:02 | 14668.29 | 25-SEP-06:02 | 5615.12 | 03-SEP-07:03 | 0.00 | 01-SEP-00:10 |
October | 0.148006E+11 | 0.354952E+10 | 365.76 | 0.953852E+10 | 0.526213E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:05 | 25914.21 | 10-OCT-06:02 | 15408.44 | 28-OCT-06:02 | 13494.80 | 23-OCT-06:02 | 5496.09 | 07-OCT-06:02 | 0.00 | 01-OCT-00:05 |
November | 0.123145E+11 | 0.293569E+10 | 353.80 | 0.792075E+10 | 0.439373E+10 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 25707.59 | 24-NOV-07:02 | 16604.81 | 15-NOV-07:02 | 12323.95 | 24-NOV-07:02 | 5509.89 | 23-NOV-08:62 | 0.00 | 01-NOV-00:10 |
December | 0.109578E+11 | 0.261553E+10 | 360.21 | 0.707371E+10 | 0.388406E+10 | 0.00 | 1.00 | 01-DEC-07:02 | 0.00 | 01-DEC-00:10 | 25869.15 | 03-DEC-08:61 | 18111.98 | 24-DEC-08:62 | 12567.96 | 10-DEC-08:62 | 5532.87 | 03-DEC-08:61 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.145959E+12 | 0.350727E+11 | 4298.49 | 0.949854E+11 | 0.509734E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.897518E+10 | 0.218915E+10 | 322.94 | 0.580069E+10 | 0.285293E+10 | 0.00 | 1.00 | 0.00 | 25406.72 | 15248.30 | 11110.37 | 5340.72 | 0.00 | |||||||
Maximum of Months | 0.153094E+11 | 0.370413E+10 | 374.80 | 0.100259E+11 | 0.558143E+10 | 0.00 | 1.00 | 0.00 | 26446.99 | 18111.98 | 14668.29 | 5615.12 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.151305E+11 | 0.374765E+10 | 350.23 | 0.100449E+11 | 0.508559E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 44040.64 | 01-JAN-09:02 | 29942.95 | 12-JAN-08:62 | 20088.27 | 01-JAN-09:02 | 9575.85 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 |
February | 0.162138E+11 | 0.389298E+10 | 315.86 | 0.957938E+10 | 0.663441E+10 | 0.00 | 1.00 | 06-FEB-08:62 | 0.00 | 01-FEB-00:05 | 45031.68 | 18-FEB-08:62 | 26719.27 | 13-FEB-08:62 | 24140.78 | 17-FEB-08:62 | 9582.49 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.171217E+11 | 0.421366E+10 | 356.23 | 0.111170E+11 | 0.600471E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 44629.77 | 13-MAR-07:02 | 28121.75 | 19-MAR-08:62 | 23067.92 | 13-MAR-07:02 | 9395.81 | 13-MAR-07:02 | 0.00 | 01-MAR-00:05 |
April | 0.160001E+11 | 0.398109E+10 | 339.17 | 0.107271E+11 | 0.527302E+10 | 0.00 | 1.00 | 07-APR-07:03 | 0.00 | 01-APR-00:05 | 43908.11 | 24-APR-07:03 | 27680.41 | 07-APR-07:03 | 20920.76 | 24-APR-07:03 | 9479.83 | 09-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.216280E+11 | 0.527816E+10 | 359.50 | 0.140194E+11 | 0.760854E+10 | 0.00 | 1.00 | 01-MAY-07:03 | 0.00 | 01-MAY-00:10 | 44688.57 | 15-MAY-07:02 | 29245.69 | 31-MAY-07:03 | 23173.53 | 15-MAY-07:02 | 9728.19 | 14-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.221154E+11 | 0.535851E+10 | 353.12 | 0.141466E+11 | 0.796882E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 43959.77 | 18-JUN-08:61 | 27186.24 | 27-JUN-07:02 | 18846.04 | 25-JUN-08:03 | 9790.58 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.259600E+11 | 0.629829E+10 | 354.34 | 0.164652E+11 | 0.949480E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 45390.28 | 23-JUL-08:61 | 28018.97 | 04-JUL-08:61 | 23151.99 | 23-JUL-08:03 | 9857.62 | 23-JUL-08:13 | 0.00 | 01-JUL-00:05 |
August | 0.271056E+11 | 0.663922E+10 | 366.12 | 0.174021E+11 | 0.970356E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 44949.84 | 20-AUG-08:61 | 27364.99 | 23-AUG-07:02 | 21735.91 | 20-AUG-08:04 | 9942.51 | 20-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.261624E+11 | 0.627986E+10 | 346.60 | 0.159914E+11 | 0.101710E+11 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 45640.04 | 25-SEP-07:02 | 27176.23 | 19-SEP-07:02 | 25586.12 | 25-SEP-07:02 | 10046.73 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.262132E+11 | 0.636303E+10 | 355.34 | 0.165380E+11 | 0.967512E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:05 | 44724.97 | 10-OCT-07:02 | 26767.57 | 28-OCT-07:03 | 23502.64 | 23-OCT-07:03 | 9875.89 | 08-OCT-08:62 | 0.00 | 01-OCT-00:05 |
November | 0.213974E+11 | 0.516335E+10 | 346.40 | 0.134172E+11 | 0.798015E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 44475.21 | 24-NOV-08:62 | 28693.49 | 15-NOV-08:62 | 21348.52 | 24-NOV-08:04 | 9833.86 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.187831E+11 | 0.454221E+10 | 350.06 | 0.117843E+11 | 0.699883E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 44875.13 | 03-DEC-09:01 | 31228.15 | 25-DEC-09:02 | 21964.75 | 03-DEC-09:04 | 9722.97 | 03-DEC-09:01 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.253831E+12 | 0.617580E+11 | 4192.97 | 0.161233E+12 | 0.925986E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.151305E+11 | 0.374765E+10 | 315.86 | 0.957938E+10 | 0.508559E+10 | 0.00 | 1.00 | 0.00 | 43908.11 | 26719.27 | 18846.04 | 9395.81 | 0.00 | |||||||
Maximum of Months | 0.271056E+11 | 0.663922E+10 | 366.12 | 0.174021E+11 | 0.101710E+11 | 0.00 | 1.00 | 0.00 | 45640.04 | 31228.15 | 25586.12 | 10046.73 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.777666E+10 | 0.189560E+10 | 350.35 | 0.516730E+10 | 0.260936E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 22906.62 | 01-JAN-09:02 | 14426.18 | 12-JAN-08:62 | 10460.80 | 01-JAN-09:02 | 4891.91 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 |
February | 0.833402E+10 | 0.196919E+10 | 315.81 | 0.492673E+10 | 0.340728E+10 | 0.00 | 1.00 | 06-FEB-08:62 | 0.00 | 01-FEB-00:05 | 23404.28 | 18-FEB-08:62 | 12916.26 | 13-FEB-08:62 | 12522.02 | 17-FEB-08:62 | 4894.90 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.880642E+10 | 0.213248E+10 | 356.29 | 0.572085E+10 | 0.308557E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 23225.82 | 13-MAR-07:02 | 14626.69 | 19-MAR-08:62 | 12036.89 | 13-MAR-07:02 | 4800.45 | 13-MAR-07:02 | 0.00 | 01-MAR-00:05 |
April | 0.823231E+10 | 0.201540E+10 | 339.25 | 0.552289E+10 | 0.270942E+10 | 0.00 | 1.00 | 09-APR-08:62 | 0.00 | 01-APR-00:05 | 22840.71 | 24-APR-07:03 | 14194.80 | 11-APR-07:03 | 10892.67 | 24-APR-07:03 | 4842.85 | 09-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.111594E+11 | 0.267983E+10 | 360.45 | 0.723680E+10 | 0.392255E+10 | 0.00 | 1.00 | 04-MAY-07:03 | 0.00 | 01-MAY-00:10 | 23257.82 | 15-MAY-07:02 | 14560.17 | 23-MAY-07:03 | 12108.07 | 15-MAY-07:02 | 4969.56 | 14-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.114020E+11 | 0.271901E+10 | 354.41 | 0.729808E+10 | 0.410389E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 22858.66 | 18-JUN-08:61 | 14170.95 | 27-JUN-07:02 | 9812.34 | 25-JUN-08:03 | 5001.32 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.134219E+11 | 0.320553E+10 | 356.13 | 0.851762E+10 | 0.490427E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 23606.32 | 23-JUL-08:61 | 14557.45 | 04-JUL-08:61 | 12088.64 | 23-JUL-08:61 | 5035.54 | 23-JUL-08:13 | 0.00 | 01-JUL-00:05 |
August | 0.140186E+11 | 0.338036E+10 | 367.76 | 0.900501E+10 | 0.501359E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 23379.19 | 20-AUG-08:61 | 14247.18 | 23-AUG-07:02 | 11341.50 | 20-AUG-08:04 | 5078.88 | 20-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.135176E+11 | 0.319343E+10 | 347.07 | 0.826763E+10 | 0.525000E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 23759.82 | 25-SEP-07:02 | 14180.99 | 19-SEP-07:02 | 13396.69 | 25-SEP-07:02 | 5132.07 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.135619E+11 | 0.323994E+10 | 355.40 | 0.856144E+10 | 0.500045E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:05 | 23278.94 | 10-OCT-07:02 | 13956.26 | 28-OCT-07:03 | 12256.87 | 23-OCT-07:03 | 5044.83 | 08-OCT-08:62 | 0.00 | 01-OCT-00:05 |
November | 0.110359E+11 | 0.262083E+10 | 346.38 | 0.692637E+10 | 0.410953E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 23136.58 | 24-NOV-08:62 | 14937.80 | 15-NOV-08:62 | 11134.55 | 24-NOV-08:04 | 5023.20 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.967355E+10 | 0.230223E+10 | 351.03 | 0.607467E+10 | 0.359887E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 23332.66 | 03-DEC-09:01 | 16251.11 | 25-DEC-09:02 | 11434.56 | 03-DEC-09:04 | 4966.73 | 03-DEC-09:01 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.130940E+12 | 0.313538E+11 | 4200.33 | 0.832254E+11 | 0.477148E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.777666E+10 | 0.189560E+10 | 315.81 | 0.492673E+10 | 0.260936E+10 | 0.00 | 1.00 | 0.00 | 22840.71 | 12916.26 | 9812.34 | 4800.45 | 0.00 | |||||||
Maximum of Months | 0.140186E+11 | 0.338036E+10 | 367.76 | 0.900501E+10 | 0.525000E+10 | 0.00 | 1.00 | 0.00 | 23759.82 | 16251.11 | 13396.69 | 5132.07 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.770222E+10 | 0.187796E+10 | 350.35 | 0.511124E+10 | 0.259098E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 22785.77 | 01-JAN-09:02 | 13992.43 | 12-JAN-08:62 | 10426.55 | 01-JAN-09:02 | 4866.37 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 |
February | 0.825887E+10 | 0.195168E+10 | 315.72 | 0.487357E+10 | 0.338530E+10 | 0.00 | 1.00 | 06-FEB-08:62 | 0.00 | 01-FEB-00:05 | 23284.70 | 18-FEB-08:62 | 12775.76 | 24-FEB-08:62 | 12492.02 | 17-FEB-08:62 | 4869.43 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.872890E+10 | 0.211403E+10 | 355.81 | 0.566328E+10 | 0.306562E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 23102.45 | 13-MAR-07:02 | 14527.06 | 19-MAR-08:62 | 11993.92 | 13-MAR-07:02 | 4775.36 | 13-MAR-07:02 | 0.00 | 01-MAR-00:05 |
April | 0.816538E+10 | 0.199928E+10 | 339.13 | 0.547210E+10 | 0.269328E+10 | 0.00 | 1.00 | 09-APR-08:62 | 0.00 | 01-APR-00:05 | 22719.99 | 24-APR-07:03 | 14085.00 | 11-APR-07:03 | 10856.27 | 24-APR-07:03 | 4817.52 | 09-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.110924E+11 | 0.266354E+10 | 360.32 | 0.718558E+10 | 0.390683E+10 | 0.00 | 1.00 | 04-MAY-07:03 | 0.00 | 01-MAY-00:10 | 23134.94 | 15-MAY-07:02 | 14452.53 | 23-MAY-07:03 | 12063.80 | 15-MAY-07:02 | 4943.65 | 14-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.113363E+11 | 0.270322E+10 | 354.59 | 0.724790E+10 | 0.408842E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 22738.23 | 18-JUN-08:61 | 14066.90 | 27-JUN-07:02 | 9781.23 | 25-JUN-08:03 | 4975.25 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.133583E+11 | 0.318979E+10 | 356.13 | 0.846837E+10 | 0.488994E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 23482.33 | 23-JUL-08:61 | 14458.45 | 04-JUL-08:61 | 12044.12 | 23-JUL-08:61 | 5009.31 | 23-JUL-08:13 | 0.00 | 01-JUL-00:05 |
August | 0.139565E+11 | 0.336471E+10 | 367.66 | 0.895636E+10 | 0.500009E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 23257.25 | 20-AUG-08:61 | 14146.60 | 23-AUG-07:02 | 11295.23 | 20-AUG-08:03 | 5052.45 | 20-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.134535E+11 | 0.317766E+10 | 347.07 | 0.821879E+10 | 0.523472E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 23634.30 | 25-SEP-07:02 | 14073.84 | 19-SEP-07:02 | 13340.91 | 25-SEP-07:02 | 5105.36 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.134973E+11 | 0.322387E+10 | 355.37 | 0.851142E+10 | 0.498584E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:05 | 23155.88 | 10-OCT-07:02 | 13848.80 | 28-OCT-07:03 | 12209.53 | 23-OCT-07:03 | 5018.56 | 08-OCT-08:62 | 0.00 | 01-OCT-00:05 |
November | 0.109641E+11 | 0.260378E+10 | 346.27 | 0.687249E+10 | 0.409160E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 23014.29 | 24-NOV-08:62 | 14829.05 | 15-NOV-08:62 | 11096.08 | 24-NOV-08:04 | 4997.09 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.959886E+10 | 0.228467E+10 | 350.77 | 0.601888E+10 | 0.357997E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 23210.11 | 03-DEC-09:01 | 16138.61 | 25-DEC-09:02 | 11391.79 | 03-DEC-09:04 | 4940.87 | 03-DEC-09:01 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.130113E+12 | 0.311542E+11 | 4199.18 | 0.826000E+11 | 0.475126E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.770222E+10 | 0.187796E+10 | 315.72 | 0.487357E+10 | 0.259098E+10 | 0.00 | 1.00 | 0.00 | 22719.99 | 12775.76 | 9781.23 | 4775.36 | 0.00 | |||||||
Maximum of Months | 0.139565E+11 | 0.336471E+10 | 367.66 | 0.895636E+10 | 0.523472E+10 | 0.00 | 1.00 | 0.00 | 23634.30 | 16138.61 | 13340.91 | 5105.36 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.761148E+10 | 0.185766E+10 | 349.73 | 0.504719E+10 | 0.256430E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 22784.57 | 01-JAN-09:02 | 13307.93 | 04-JAN-08:62 | 10465.34 | 01-JAN-09:02 | 4867.58 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 |
February | 0.815339E+10 | 0.192880E+10 | 315.21 | 0.480374E+10 | 0.334965E+10 | 0.00 | 1.00 | 17-FEB-08:62 | 0.00 | 01-FEB-00:05 | 23288.23 | 18-FEB-08:62 | 12151.79 | 28-FEB-08:62 | 12566.21 | 17-FEB-08:62 | 4870.95 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.863246E+10 | 0.209256E+10 | 354.91 | 0.559690E+10 | 0.303556E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 23103.49 | 13-MAR-07:02 | 14497.16 | 19-MAR-08:62 | 12029.53 | 13-MAR-07:02 | 4776.63 | 13-MAR-07:02 | 0.00 | 01-MAR-00:05 |
April | 0.811108E+10 | 0.198704E+10 | 338.96 | 0.543413E+10 | 0.267695E+10 | 0.00 | 1.00 | 09-APR-08:62 | 0.00 | 01-APR-00:05 | 22719.82 | 24-APR-07:03 | 13614.40 | 10-APR-07:03 | 10891.48 | 24-APR-07:03 | 4818.46 | 09-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.110868E+11 | 0.266237E+10 | 360.45 | 0.718260E+10 | 0.390420E+10 | 0.00 | 1.00 | 05-MAY-07:03 | 0.00 | 01-MAY-00:10 | 23135.98 | 15-MAY-07:02 | 14117.78 | 20-MAY-07:02 | 12094.11 | 15-MAY-07:02 | 4945.03 | 14-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.113370E+11 | 0.270351E+10 | 354.54 | 0.724967E+10 | 0.408733E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 22740.20 | 18-JUN-08:61 | 14041.29 | 27-JUN-07:02 | 9805.87 | 25-JUN-08:03 | 4976.70 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.133848E+11 | 0.319619E+10 | 356.06 | 0.848955E+10 | 0.489529E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 23486.34 | 23-JUL-08:61 | 14439.12 | 04-JUL-08:61 | 12061.89 | 23-JUL-08:61 | 5010.89 | 23-JUL-08:13 | 0.00 | 01-JUL-00:05 |
August | 0.140010E+11 | 0.337533E+10 | 368.26 | 0.899059E+10 | 0.501038E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 23261.10 | 20-AUG-08:61 | 14126.93 | 23-AUG-07:02 | 11308.28 | 20-AUG-08:04 | 5054.06 | 20-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.134710E+11 | 0.318197E+10 | 346.95 | 0.823279E+10 | 0.523818E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 23638.83 | 25-SEP-07:02 | 14054.63 | 19-SEP-07:02 | 13356.46 | 25-SEP-07:02 | 5106.99 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.135167E+11 | 0.322867E+10 | 355.42 | 0.852686E+10 | 0.498984E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:05 | 23159.66 | 10-OCT-07:02 | 13826.07 | 28-OCT-07:03 | 12233.22 | 23-OCT-07:03 | 5020.17 | 08-OCT-08:62 | 0.00 | 01-OCT-00:05 |
November | 0.109244E+11 | 0.259566E+10 | 346.35 | 0.684566E+10 | 0.407869E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 23015.21 | 24-NOV-08:62 | 14779.09 | 15-NOV-08:62 | 11123.13 | 24-NOV-08:04 | 4998.50 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.952984E+10 | 0.226975E+10 | 350.00 | 0.597102E+10 | 0.355882E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 23212.45 | 03-DEC-09:01 | 15928.76 | 24-DEC-09:02 | 11417.35 | 03-DEC-09:04 | 4942.44 | 03-DEC-09:01 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.129760E+12 | 0.310795E+11 | 4196.82 | 0.823707E+11 | 0.473892E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.761148E+10 | 0.185766E+10 | 315.21 | 0.480374E+10 | 0.256430E+10 | 0.00 | 1.00 | 0.00 | 22719.82 | 12151.79 | 9805.87 | 4776.63 | 0.00 | |||||||
Maximum of Months | 0.140010E+11 | 0.337533E+10 | 368.26 | 0.899059E+10 | 0.523818E+10 | 0.00 | 1.00 | 0.00 | 23638.83 | 15928.76 | 13356.46 | 5106.99 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.856236E+10 | 0.208765E+10 | 351.19 | 0.582633E+10 | 0.273602E+10 | 0.00 | 1.00 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 | 25213.94 | 02-JAN-08:62 | 14584.06 | 08-JAN-09:02 | 11788.92 | 31-JAN-08:62 | 5390.49 | 01-JAN-09:02 | 0.00 | 01-JAN-00:05 |
February | 0.889825E+10 | 0.211220E+10 | 314.62 | 0.538823E+10 | 0.351002E+10 | 0.00 | 1.00 | 17-FEB-08:62 | 0.00 | 01-FEB-00:05 | 26146.81 | 18-FEB-08:62 | 12323.55 | 28-FEB-08:62 | 15144.70 | 18-FEB-08:62 | 5394.00 | 18-FEB-08:62 | 0.00 | 01-FEB-00:05 |
March | 0.956705E+10 | 0.232113E+10 | 352.79 | 0.636334E+10 | 0.320371E+10 | 0.00 | 1.00 | 02-MAR-08:62 | 0.00 | 01-MAR-00:05 | 25639.34 | 13-MAR-07:02 | 14437.75 | 02-MAR-08:62 | 13393.39 | 13-MAR-07:02 | 5292.73 | 13-MAR-07:02 | 0.00 | 01-MAR-00:05 |
April | 0.933583E+10 | 0.227911E+10 | 340.13 | 0.641565E+10 | 0.292018E+10 | 0.00 | 1.00 | 09-APR-08:62 | 0.00 | 01-APR-00:05 | 24776.17 | 09-APR-08:62 | 15106.76 | 10-APR-07:03 | 9826.25 | 09-APR-08:62 | 5346.89 | 09-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.128212E+11 | 0.307259E+10 | 361.81 | 0.854671E+10 | 0.427445E+10 | 0.00 | 1.00 | 06-MAY-07:02 | 0.00 | 01-MAY-00:10 | 25626.65 | 15-MAY-07:02 | 15795.70 | 30-MAY-07:03 | 13232.60 | 15-MAY-07:02 | 5480.27 | 14-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.130980E+11 | 0.311733E+10 | 355.58 | 0.861140E+10 | 0.448660E+10 | 0.00 | 1.00 | 01-JUN-07:02 | 0.00 | 01-JUN-00:10 | 25299.56 | 25-JUN-08:61 | 15708.57 | 04-JUN-08:62 | 11518.33 | 14-JUN-07:02 | 5514.12 | 18-JUN-08:61 | 0.00 | 01-JUN-00:10 |
July | 0.153942E+11 | 0.367669E+10 | 356.82 | 0.100471E+11 | 0.534711E+10 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:05 | 26169.06 | 23-JUL-08:61 | 15715.54 | 04-JUL-08:61 | 13707.13 | 20-JUL-07:02 | 5550.21 | 23-JUL-08:13 | 0.00 | 01-JUL-00:05 |
August | 0.161932E+11 | 0.390387E+10 | 369.18 | 0.107016E+11 | 0.549159E+10 | 0.00 | 1.00 | 01-AUG-07:02 | 0.00 | 01-AUG-00:10 | 25909.45 | 20-AUG-08:61 | 15104.66 | 23-AUG-07:02 | 12495.65 | 20-AUG-08:04 | 5598.27 | 20-AUG-08:13 | 0.00 | 01-AUG-00:10 |
September | 0.151776E+11 | 0.359397E+10 | 348.17 | 0.953962E+10 | 0.563799E+10 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 26206.08 | 25-SEP-07:02 | 15279.91 | 19-SEP-07:02 | 14705.01 | 25-SEP-07:02 | 5657.09 | 03-SEP-08:13 | 0.00 | 01-SEP-00:10 |
October | 0.153969E+11 | 0.368389E+10 | 355.63 | 0.100057E+11 | 0.539117E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:05 | 25702.31 | 10-OCT-07:02 | 14955.87 | 27-OCT-07:02 | 13375.26 | 10-OCT-07:02 | 5560.67 | 08-OCT-08:03 | 0.00 | 01-OCT-00:05 |
November | 0.122113E+11 | 0.290571E+10 | 348.24 | 0.785032E+10 | 0.436100E+10 | 0.00 | 1.00 | 01-NOV-07:02 | 0.00 | 01-NOV-00:10 | 25553.00 | 06-NOV-08:62 | 16456.70 | 15-NOV-08:62 | 12348.71 | 24-NOV-08:62 | 5545.70 | 23-NOV-09:01 | 0.00 | 01-NOV-00:10 |
December | 0.106216E+11 | 0.253332E+10 | 350.43 | 0.683362E+10 | 0.378794E+10 | 0.00 | 1.00 | 01-DEC-08:62 | 0.00 | 01-DEC-00:10 | 25820.80 | 03-DEC-09:01 | 18052.30 | 24-DEC-09:02 | 12683.54 | 03-DEC-09:04 | 5474.54 | 03-DEC-09:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.147277E+12 | 0.352875E+11 | 4204.60 | 0.961296E+11 | 0.511478E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.856236E+10 | 0.208765E+10 | 314.62 | 0.538823E+10 | 0.273602E+10 | 0.00 | 1.00 | 0.00 | 24776.17 | 12323.55 | 9826.25 | 5292.73 | 0.00 | |||||||
Maximum of Months | 0.161932E+11 | 0.390387E+10 | 369.18 | 0.107016E+11 | 0.563799E+10 | 0.00 | 1.00 | 0.00 | 26206.08 | 18052.30 | 15144.70 | 5657.09 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.25 | 23.32 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.55 | 22.05 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.99 | 21.68 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.57 | 18.09 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.33 | 13.03 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.79 | 9.93 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.09 | 7.16 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 46.99 | 8.28 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.52 | 7.40 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.06 | 12.45 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.50 | 14.97 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.74 | 17.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.37 | 14.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.57 | 7.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.74 | 23.32 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.25 | 23.32 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.55 | 22.05 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.99 | 21.68 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.57 | 18.09 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.33 | 13.03 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.79 | 9.93 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.09 | 7.16 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 46.99 | 8.28 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.52 | 7.40 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.06 | 12.45 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.50 | 14.97 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.74 | 17.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.37 | 14.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.57 | 7.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.74 | 23.32 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.25 | 23.32 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.55 | 22.05 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.99 | 21.68 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.57 | 18.09 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.33 | 13.03 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.79 | 9.93 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.09 | 7.16 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 46.99 | 8.28 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.52 | 7.40 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.06 | 12.45 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.50 | 14.97 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.74 | 17.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.37 | 14.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.57 | 7.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.74 | 23.32 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.25 | 23.32 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.55 | 22.05 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.99 | 21.68 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.57 | 18.09 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.33 | 13.03 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.79 | 9.93 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.09 | 7.16 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 46.99 | 8.28 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.52 | 7.40 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.06 | 12.45 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.50 | 14.97 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.74 | 17.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.37 | 14.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.57 | 7.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.74 | 23.32 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.40 | 50.49 | 29.91 | 134.79 | 27.97 | 0.00 | 0.00 | 744.00 |
February | 68.10 | 36.30 | 31.80 | 111.12 | 26.44 | 0.00 | 0.00 | 672.00 |
March | 49.41 | 16.93 | 32.48 | 76.79 | 26.00 | 0.00 | 0.00 | 744.00 |
April | 31.95 | 3.08 | 28.87 | 48.63 | 21.71 | 0.00 | 0.00 | 720.00 |
May | 27.04 | 0.07 | 26.97 | 49.47 | 15.66 | 0.00 | 0.00 | 744.00 |
June | 26.75 | 0.00 | 26.75 | 48.81 | 11.97 | 0.00 | 0.00 | 720.00 |
July | 25.94 | 0.07 | 25.87 | 52.72 | 8.65 | 0.00 | 0.00 | 744.00 |
August | 28.37 | 1.74 | 26.63 | 56.19 | 10.00 | 0.00 | 0.00 | 744.00 |
September | 42.88 | 10.41 | 32.47 | 76.09 | 8.94 | 0.00 | 0.00 | 720.00 |
October | 60.79 | 29.36 | 31.43 | 110.39 | 14.99 | 0.00 | 0.00 | 744.00 |
November | 76.76 | 44.00 | 32.76 | 135.02 | 18.01 | 0.00 | 0.00 | 720.00 |
December | 83.06 | 53.52 | 29.54 | 142.57 | 21.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.03 | 20.43 | 29.60 | 86.79 | 17.59 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.94 | 0.00 | 25.87 | 48.63 | 8.65 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 83.06 | 53.52 | 32.76 | 142.57 | 27.97 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.40 | 50.49 | 29.91 | 134.79 | 27.97 | 0.00 | 0.00 | 744.00 |
February | 68.10 | 36.30 | 31.80 | 111.12 | 26.44 | 0.00 | 0.00 | 672.00 |
March | 49.41 | 16.93 | 32.48 | 76.79 | 26.00 | 0.00 | 0.00 | 744.00 |
April | 31.95 | 3.08 | 28.87 | 48.63 | 21.71 | 0.00 | 0.00 | 720.00 |
May | 27.04 | 0.07 | 26.97 | 49.47 | 15.66 | 0.00 | 0.00 | 744.00 |
June | 26.75 | 0.00 | 26.75 | 48.81 | 11.97 | 0.00 | 0.00 | 720.00 |
July | 25.94 | 0.07 | 25.87 | 52.72 | 8.65 | 0.00 | 0.00 | 744.00 |
August | 28.37 | 1.74 | 26.63 | 56.19 | 10.00 | 0.00 | 0.00 | 744.00 |
September | 42.88 | 10.41 | 32.47 | 76.09 | 8.94 | 0.00 | 0.00 | 720.00 |
October | 60.79 | 29.36 | 31.43 | 110.39 | 14.99 | 0.00 | 0.00 | 744.00 |
November | 76.76 | 44.00 | 32.76 | 135.02 | 18.01 | 0.00 | 0.00 | 720.00 |
December | 83.06 | 53.52 | 29.54 | 142.57 | 21.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.03 | 20.43 | 29.60 | 86.79 | 17.59 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.94 | 0.00 | 25.87 | 48.63 | 8.65 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 83.06 | 53.52 | 32.76 | 142.57 | 27.97 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.07 | 23.60 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.47 | 22.27 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.06 | 21.89 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.71 | 18.23 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.61 | 13.08 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.14 | 9.87 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.57 | 7.03 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.51 | 8.11 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 64.04 | 7.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.32 | 12.43 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.54 | 14.98 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.63 | 17.83 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.56 | 14.67 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.71 | 7.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.63 | 23.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.07 | 23.60 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.47 | 22.27 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.06 | 21.89 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.71 | 18.23 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.61 | 13.08 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.14 | 9.87 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.57 | 7.03 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.51 | 8.11 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 64.04 | 7.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.32 | 12.43 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.54 | 14.98 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.63 | 17.83 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.56 | 14.67 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.71 | 7.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.63 | 23.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.40 | 50.49 | 29.91 | 134.58 | 28.31 | 0.00 | 0.00 | 744.00 |
February | 68.10 | 36.30 | 31.80 | 111.04 | 26.70 | 0.00 | 0.00 | 672.00 |
March | 49.41 | 16.93 | 32.48 | 76.88 | 26.24 | 0.00 | 0.00 | 744.00 |
April | 31.95 | 3.08 | 28.87 | 48.80 | 21.88 | 0.00 | 0.00 | 720.00 |
May | 27.04 | 0.07 | 26.97 | 49.80 | 15.72 | 0.00 | 0.00 | 744.00 |
June | 26.75 | 0.00 | 26.75 | 49.24 | 11.89 | 0.00 | 0.00 | 720.00 |
July | 25.94 | 0.07 | 25.87 | 53.30 | 8.49 | 0.00 | 0.00 | 744.00 |
August | 28.37 | 1.74 | 26.63 | 56.81 | 9.79 | 0.00 | 0.00 | 744.00 |
September | 42.88 | 10.41 | 32.47 | 76.72 | 8.66 | 0.00 | 0.00 | 720.00 |
October | 60.79 | 29.36 | 31.43 | 110.70 | 14.95 | 0.00 | 0.00 | 744.00 |
November | 76.76 | 44.00 | 32.76 | 135.08 | 18.02 | 0.00 | 0.00 | 720.00 |
December | 83.06 | 53.52 | 29.54 | 142.45 | 21.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 50.03 | 20.43 | 29.60 | 87.03 | 17.63 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.94 | 0.00 | 25.87 | 48.80 | 8.49 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 83.06 | 53.52 | 32.76 | 142.45 | 28.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.17 | 25.02 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.46 | 23.70 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.93 | 23.25 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.64 | 19.63 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.47 | 14.77 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.03 | 11.65 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.22 | 9.03 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.31 | 10.08 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.47 | 9.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.07 | 14.48 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.60 | 16.77 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.74 | 19.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.43 | 16.38 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.64 | 9.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.74 | 25.02 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.17 | 25.02 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.46 | 23.70 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.93 | 23.25 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.64 | 19.63 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.47 | 14.77 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.03 | 11.65 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.22 | 9.03 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.31 | 10.08 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.47 | 9.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.07 | 14.48 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.60 | 16.77 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.74 | 19.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.43 | 16.38 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.64 | 9.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.74 | 25.02 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 133.96 | 29.80 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.42 | 28.21 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.31 | 27.68 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.46 | 23.39 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.37 | 17.60 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 48.83 | 13.91 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.59 | 10.79 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.27 | 12.03 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.63 | 10.95 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.81 | 17.27 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.42 | 20.01 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.80 | 23.26 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.40 | 19.53 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.46 | 10.79 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.80 | 29.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.19 | 24.96 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.48 | 23.65 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.94 | 23.22 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.66 | 19.60 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.47 | 14.81 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.02 | 11.72 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.19 | 9.16 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.29 | 10.19 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.43 | 9.33 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.05 | 14.61 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.61 | 16.80 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.75 | 19.50 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.43 | 16.42 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.66 | 9.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.75 | 24.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.19 | 24.96 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.48 | 23.65 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.94 | 23.22 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.66 | 19.60 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.47 | 14.81 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.02 | 11.72 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.19 | 9.16 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.29 | 10.19 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.43 | 9.33 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.05 | 14.61 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.61 | 16.80 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.75 | 19.50 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.43 | 16.42 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.66 | 9.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.75 | 24.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 133.98 | 29.72 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.44 | 28.15 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.32 | 27.64 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.48 | 23.35 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.37 | 17.65 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 48.82 | 13.99 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.57 | 10.94 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.25 | 12.17 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.59 | 11.14 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.78 | 17.42 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.42 | 20.04 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.81 | 23.24 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.39 | 19.58 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.48 | 10.94 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.81 | 29.72 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.30 | 24.62 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.60 | 23.30 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.06 | 22.86 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.77 | 19.26 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.58 | 14.50 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.13 | 11.41 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.30 | 8.87 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.39 | 9.89 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.53 | 9.03 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.14 | 14.30 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.71 | 16.50 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.86 | 19.17 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.54 | 16.11 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.77 | 8.87 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.86 | 24.62 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.30 | 24.62 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.60 | 23.30 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.06 | 22.86 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.77 | 19.26 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.58 | 14.50 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.13 | 11.41 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.30 | 8.87 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.39 | 9.89 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.53 | 9.03 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.14 | 14.30 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.71 | 16.50 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.86 | 19.17 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.54 | 16.11 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.77 | 8.87 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.86 | 24.62 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 134.11 | 29.32 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.59 | 27.74 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.46 | 27.22 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.62 | 22.94 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.50 | 17.28 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 48.96 | 13.63 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.69 | 10.60 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.37 | 11.81 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.70 | 10.80 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.89 | 17.06 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.54 | 19.68 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.93 | 22.86 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.52 | 19.20 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.62 | 10.60 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.93 | 29.32 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.38 | 23.64 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.73 | 22.31 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.16 | 21.86 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.76 | 18.29 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.42 | 13.55 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.89 | 10.46 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 43.97 | 7.98 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.09 | 8.91 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.31 | 8.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 91.98 | 13.39 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.62 | 15.60 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.87 | 18.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.44 | 15.16 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.76 | 7.98 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.87 | 23.64 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.38 | 23.64 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.73 | 22.31 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.16 | 21.86 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.76 | 18.29 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.42 | 13.55 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.89 | 10.46 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 43.97 | 7.98 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.09 | 8.91 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.31 | 8.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 91.98 | 13.39 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.62 | 15.60 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.87 | 18.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.44 | 15.16 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.76 | 7.98 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.87 | 23.64 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.38 | 23.64 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.73 | 22.31 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.16 | 21.86 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.76 | 18.29 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.42 | 13.55 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.89 | 10.46 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 43.97 | 7.98 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.09 | 8.91 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.31 | 8.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 91.98 | 13.39 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.62 | 15.60 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.87 | 18.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.44 | 15.16 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.76 | 7.98 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.87 | 23.64 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.38 | 23.64 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.73 | 22.31 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.16 | 21.86 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.76 | 18.29 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.42 | 13.55 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.89 | 10.46 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 43.97 | 7.98 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.09 | 8.91 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.31 | 8.17 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 91.98 | 13.39 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.62 | 15.60 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.87 | 18.23 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.44 | 15.16 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.76 | 7.98 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.87 | 23.64 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 134.22 | 28.16 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.75 | 26.56 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.59 | 26.03 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.62 | 21.79 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.33 | 16.16 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 48.70 | 12.50 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.32 | 9.55 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.03 | 10.66 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.46 | 9.77 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.71 | 15.98 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.44 | 18.62 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.95 | 21.74 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.42 | 18.08 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.62 | 9.55 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.95 | 28.16 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 134.22 | 28.16 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.75 | 26.56 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.59 | 26.03 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.62 | 21.79 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.33 | 16.16 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 48.70 | 12.50 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.32 | 9.55 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.03 | 10.66 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.46 | 9.77 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.71 | 15.98 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.44 | 18.62 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.95 | 21.74 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.42 | 18.08 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.62 | 9.55 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.95 | 28.16 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.34 | 23.35 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.72 | 22.00 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.24 | 21.55 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.91 | 17.97 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.65 | 13.22 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.15 | 10.09 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.27 | 7.60 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.40 | 8.52 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.56 | 7.77 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.13 | 13.00 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.65 | 15.23 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.83 | 17.88 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.58 | 14.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.91 | 7.60 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.83 | 23.35 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.34 | 23.35 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.72 | 22.00 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.24 | 21.55 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.91 | 17.97 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.65 | 13.22 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.15 | 10.09 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.27 | 7.60 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.40 | 8.52 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.56 | 7.77 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.13 | 13.00 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.65 | 15.23 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.83 | 17.88 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.58 | 14.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.91 | 7.60 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.83 | 23.35 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 134.18 | 27.81 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.76 | 26.19 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.70 | 25.66 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.80 | 21.42 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.60 | 15.76 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 49.00 | 12.05 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.68 | 9.09 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.40 | 10.19 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.76 | 9.29 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.90 | 15.52 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.50 | 18.17 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.93 | 21.32 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.59 | 17.66 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.80 | 9.09 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.93 | 27.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.39 | 23.25 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.78 | 21.90 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.29 | 21.45 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.96 | 17.88 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.70 | 13.14 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.20 | 10.01 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.32 | 7.53 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.44 | 8.45 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.60 | 7.69 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.17 | 12.93 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.70 | 15.14 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.88 | 17.78 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.62 | 14.73 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.96 | 7.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.88 | 23.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.39 | 23.25 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.78 | 21.90 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.29 | 21.45 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.96 | 17.88 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.70 | 13.14 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.20 | 10.01 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.32 | 7.53 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.44 | 8.45 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.60 | 7.69 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.17 | 12.93 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.70 | 15.14 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.88 | 17.78 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.62 | 14.73 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.96 | 7.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.88 | 23.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 134.24 | 27.70 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.83 | 26.07 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.76 | 25.54 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.86 | 21.31 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.66 | 15.67 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 49.06 | 11.96 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.74 | 9.01 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.45 | 10.11 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.82 | 9.20 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.95 | 15.43 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.56 | 18.06 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.99 | 21.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.65 | 17.56 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.86 | 9.01 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.99 | 27.70 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.42 | 23.10 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.82 | 21.73 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.31 | 21.30 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.96 | 17.77 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.66 | 13.10 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.16 | 9.99 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.26 | 7.55 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.37 | 8.48 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.54 | 7.72 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.12 | 12.93 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.70 | 15.07 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.90 | 17.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.61 | 14.67 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.96 | 7.55 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.90 | 23.10 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 112.42 | 23.10 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.82 | 21.73 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 64.31 | 21.30 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.96 | 17.77 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 41.66 | 13.10 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 41.16 | 9.99 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 44.26 | 7.55 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 47.37 | 8.48 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 63.54 | 7.72 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 92.12 | 12.93 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.70 | 15.07 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.90 | 17.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 72.61 | 14.67 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.96 | 7.55 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.90 | 23.10 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 134.29 | 27.52 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.88 | 25.87 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.79 | 25.36 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.86 | 21.18 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 49.62 | 15.62 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 49.02 | 11.94 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 52.66 | 9.03 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 56.36 | 10.15 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 75.74 | 9.23 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 109.89 | 15.44 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 134.56 | 17.99 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 142.01 | 21.08 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 86.63 | 17.49 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 48.86 | 9.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 142.01 | 27.52 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 111.99 | 22.73 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.47 | 21.28 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.83 | 20.91 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.25 | 17.56 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 40.69 | 13.23 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.17 | 10.21 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 43.12 | 7.99 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 46.15 | 9.02 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 62.58 | 8.25 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 91.14 | 13.38 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.07 | 15.14 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.39 | 17.55 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 71.82 | 14.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.17 | 7.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.39 | 22.73 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.78 | 41.94 | 24.84 | 111.99 | 22.73 | 0.00 | 0.00 | 744.00 |
February | 56.57 | 30.15 | 26.41 | 92.47 | 21.28 | 0.00 | 0.00 | 672.00 |
March | 41.04 | 14.06 | 26.98 | 63.83 | 20.91 | 0.00 | 0.00 | 744.00 |
April | 26.54 | 2.56 | 23.98 | 40.25 | 17.56 | 0.00 | 0.00 | 720.00 |
May | 22.46 | 0.06 | 22.40 | 40.69 | 13.23 | 0.00 | 0.00 | 744.00 |
June | 22.22 | 0.00 | 22.22 | 40.17 | 10.21 | 0.00 | 0.00 | 720.00 |
July | 21.54 | 0.06 | 21.48 | 43.12 | 7.99 | 0.00 | 0.00 | 744.00 |
August | 23.57 | 1.45 | 22.12 | 46.15 | 9.02 | 0.00 | 0.00 | 744.00 |
September | 35.61 | 8.64 | 26.97 | 62.58 | 8.25 | 0.00 | 0.00 | 720.00 |
October | 50.49 | 24.38 | 26.11 | 91.14 | 13.38 | 0.00 | 0.00 | 744.00 |
November | 63.76 | 36.55 | 27.21 | 112.07 | 15.14 | 0.00 | 0.00 | 720.00 |
December | 68.99 | 44.45 | 24.54 | 118.39 | 17.55 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.56 | 16.97 | 24.59 | 71.82 | 14.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.54 | 0.00 | 21.48 | 40.17 | 7.99 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.99 | 44.45 | 27.21 | 118.39 | 22.73 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 79.96 | 50.21 | 29.75 | 133.76 | 27.09 | 0.00 | 0.00 | 744.00 |
February | 67.73 | 36.11 | 31.63 | 110.46 | 25.34 | 0.00 | 0.00 | 672.00 |
March | 49.14 | 16.83 | 32.30 | 76.19 | 24.90 | 0.00 | 0.00 | 744.00 |
April | 31.77 | 3.06 | 28.71 | 48.01 | 20.93 | 0.00 | 0.00 | 720.00 |
May | 26.89 | 0.07 | 26.82 | 48.44 | 15.78 | 0.00 | 0.00 | 744.00 |
June | 26.60 | 0.00 | 26.60 | 47.81 | 12.21 | 0.00 | 0.00 | 720.00 |
July | 25.79 | 0.07 | 25.72 | 51.29 | 9.56 | 0.00 | 0.00 | 744.00 |
August | 28.22 | 1.73 | 26.48 | 54.89 | 10.78 | 0.00 | 0.00 | 744.00 |
September | 42.64 | 10.35 | 32.29 | 74.57 | 9.87 | 0.00 | 0.00 | 720.00 |
October | 60.46 | 29.20 | 31.26 | 108.70 | 15.97 | 0.00 | 0.00 | 744.00 |
November | 76.34 | 43.76 | 32.58 | 133.79 | 18.07 | 0.00 | 0.00 | 720.00 |
December | 82.61 | 53.23 | 29.38 | 141.39 | 20.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 49.76 | 20.32 | 29.44 | 85.68 | 17.58 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 25.79 | 0.00 | 25.72 | 47.81 | 9.56 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 82.61 | 53.23 | 32.58 | 141.39 | 27.09 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300660E+09 | 62450738.17 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223887E+09 | 53349225.09 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171387E+09 | 58078053.12 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105151E+09 | 46880657.54 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110693E+09 | 34894596.62 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105720E+09 | 25750528.01 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118095E+09 | 19186687.90 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.125846E+09 | 22181424.10 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164640E+09 | 19180335.40 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246580E+09 | 33359073.93 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291605E+09 | 38803222.45 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318045E+09 | 47410349.50 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228231E+10 | 0.461525E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105151E+09 | 19180335.40 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318045E+09 | 62450738.17 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300660E+09 | 62450738.17 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223887E+09 | 53349225.09 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171387E+09 | 58078053.12 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105151E+09 | 46880657.54 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110693E+09 | 34894596.62 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105720E+09 | 25750528.01 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118095E+09 | 19186687.90 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.125846E+09 | 22181424.10 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164640E+09 | 19180335.40 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246580E+09 | 33359073.93 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291605E+09 | 38803222.45 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318045E+09 | 47410349.50 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228231E+10 | 0.461525E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105151E+09 | 19180335.40 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318045E+09 | 62450738.17 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300660E+09 | 62450738.17 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223887E+09 | 53349225.09 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171387E+09 | 58078053.12 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105151E+09 | 46880657.54 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110693E+09 | 34894596.62 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105720E+09 | 25750528.01 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118095E+09 | 19186687.90 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.125846E+09 | 22181424.10 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164640E+09 | 19180335.40 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246580E+09 | 33359073.93 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291605E+09 | 38803222.45 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318045E+09 | 47410349.50 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228231E+10 | 0.461525E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105151E+09 | 19180335.40 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318045E+09 | 62450738.17 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300660E+09 | 62450738.17 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223887E+09 | 53349225.09 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171387E+09 | 58078053.12 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105151E+09 | 46880657.54 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110693E+09 | 34894596.62 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105720E+09 | 25750528.01 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118095E+09 | 19186687.90 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.125846E+09 | 22181424.10 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164640E+09 | 19180335.40 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246580E+09 | 33359073.93 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291605E+09 | 38803222.45 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318045E+09 | 47410349.50 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228231E+10 | 0.461525E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105151E+09 | 19180335.40 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318045E+09 | 62450738.17 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215347E+09 | 0.135231E+09 | 80116211.50 | 0.361018E+09 | 74919139.47 |
February | 0.164756E+09 | 87826583.87 | 76928993.70 | 0.268823E+09 | 63971214.38 |
March | 0.132330E+09 | 45338550.99 | 86991751.27 | 0.205667E+09 | 69638684.33 |
April | 82806678.19 | 7974935.41 | 74831742.77 | 0.126053E+09 | 56274112.29 |
May | 72428531.74 | 187007.77 | 72241523.96 | 0.132488E+09 | 41936100.85 |
June | 69332668.71 | 0.00 | 69332668.71 | 0.126520E+09 | 31036346.34 |
July | 69468645.92 | 189914.32 | 69278731.60 | 0.141205E+09 | 23180946.01 |
August | 75992808.84 | 4666735.83 | 71326073.01 | 0.150492E+09 | 26775421.76 |
September | 0.111140E+09 | 26972761.43 | 84167486.74 | 0.197213E+09 | 23166029.60 |
October | 0.162819E+09 | 78627334.95 | 84191923.48 | 0.295663E+09 | 40143473.51 |
November | 0.198960E+09 | 0.114051E+09 | 84908887.51 | 0.349982E+09 | 46677725.35 |
December | 0.222467E+09 | 0.143341E+09 | 79125921.18 | 0.381861E+09 | 56965389.37 |
Annual Sum or Average | 0.157785E+10 | 0.644407E+09 | 0.933442E+09 | 0.273698E+10 | 0.554685E+09 |
Minimum of Months | 69332668.71 | 0.00 | 69278731.60 | 0.126053E+09 | 23166029.60 |
Maximum of Months | 0.222467E+09 | 0.143341E+09 | 86991751.27 | 0.381861E+09 | 74919139.47 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215347E+09 | 0.135231E+09 | 80116211.50 | 0.361018E+09 | 74919139.47 |
February | 0.164756E+09 | 87826583.87 | 76928993.70 | 0.268823E+09 | 63971214.38 |
March | 0.132330E+09 | 45338550.99 | 86991751.27 | 0.205667E+09 | 69638684.33 |
April | 82806678.19 | 7974935.41 | 74831742.77 | 0.126053E+09 | 56274112.29 |
May | 72428531.74 | 187007.77 | 72241523.96 | 0.132488E+09 | 41936100.85 |
June | 69332668.71 | 0.00 | 69332668.71 | 0.126520E+09 | 31036346.34 |
July | 69468645.92 | 189914.32 | 69278731.60 | 0.141205E+09 | 23180946.01 |
August | 75992808.84 | 4666735.83 | 71326073.01 | 0.150492E+09 | 26775421.76 |
September | 0.111140E+09 | 26972761.43 | 84167486.74 | 0.197213E+09 | 23166029.60 |
October | 0.162819E+09 | 78627334.95 | 84191923.48 | 0.295663E+09 | 40143473.51 |
November | 0.198960E+09 | 0.114051E+09 | 84908887.51 | 0.349982E+09 | 46677725.35 |
December | 0.222467E+09 | 0.143341E+09 | 79125921.18 | 0.381861E+09 | 56965389.37 |
Annual Sum or Average | 0.157785E+10 | 0.644407E+09 | 0.933442E+09 | 0.273698E+10 | 0.554685E+09 |
Minimum of Months | 69332668.71 | 0.00 | 69278731.60 | 0.126053E+09 | 23166029.60 |
Maximum of Months | 0.222467E+09 | 0.143341E+09 | 86991751.27 | 0.381861E+09 | 74919139.47 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300175E+09 | 63207909.07 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223704E+09 | 53875241.17 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171572E+09 | 58637819.72 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105520E+09 | 47249143.83 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111440E+09 | 35035563.20 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106635E+09 | 25580021.30 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.119382E+09 | 18832028.14 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.127243E+09 | 21726947.71 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.166000E+09 | 18594861.87 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.247272E+09 | 33280618.66 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291699E+09 | 38821779.48 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.317739E+09 | 47764556.30 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228838E+10 | 0.462606E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105520E+09 | 18594861.87 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.317739E+09 | 63207909.07 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300175E+09 | 63207909.07 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223704E+09 | 53875241.17 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171572E+09 | 58637819.72 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105520E+09 | 47249143.83 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111440E+09 | 35035563.20 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106635E+09 | 25580021.30 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.119382E+09 | 18832028.14 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.127243E+09 | 21726947.71 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.166000E+09 | 18594861.87 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.247272E+09 | 33280618.66 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291699E+09 | 38821779.48 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.317739E+09 | 47764556.30 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228838E+10 | 0.462606E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105520E+09 | 18594861.87 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.317739E+09 | 63207909.07 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215347E+09 | 0.135231E+09 | 80116211.50 | 0.360469E+09 | 75815962.35 |
February | 0.164756E+09 | 87826583.87 | 76928993.70 | 0.268632E+09 | 64589854.52 |
March | 0.132330E+09 | 45338550.99 | 86991751.27 | 0.205905E+09 | 70293745.55 |
April | 82806678.19 | 7974935.41 | 74831742.77 | 0.126502E+09 | 56702385.20 |
May | 72428531.74 | 187007.77 | 72241523.96 | 0.133389E+09 | 42095790.20 |
June | 69332668.71 | 0.00 | 69332668.71 | 0.127623E+09 | 30829190.03 |
July | 69468645.92 | 189914.32 | 69278731.60 | 0.142752E+09 | 22751542.74 |
August | 75992808.84 | 4666735.83 | 71326073.01 | 0.152164E+09 | 26224865.38 |
September | 0.111140E+09 | 26972761.43 | 84167486.74 | 0.198853E+09 | 22454147.40 |
October | 0.162819E+09 | 78627334.95 | 84191923.48 | 0.296511E+09 | 40042923.72 |
November | 0.198960E+09 | 0.114051E+09 | 84908887.51 | 0.350128E+09 | 46695595.66 |
December | 0.222467E+09 | 0.143341E+09 | 79125921.18 | 0.381535E+09 | 57382436.63 |
Annual Sum or Average | 0.157785E+10 | 0.644407E+09 | 0.933442E+09 | 0.274446E+10 | 0.555878E+09 |
Minimum of Months | 69332668.71 | 0.00 | 69278731.60 | 0.126502E+09 | 22454147.40 |
Maximum of Months | 0.222467E+09 | 0.143341E+09 | 86991751.27 | 0.381535E+09 | 75815962.35 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300425E+09 | 67018297.09 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223673E+09 | 57331088.13 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171226E+09 | 62267329.46 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105337E+09 | 50891875.57 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111074E+09 | 39550237.89 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106337E+09 | 30201640.27 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118437E+09 | 24188655.98 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126717E+09 | 26985560.23 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164512E+09 | 23758489.71 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246603E+09 | 38790005.81 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291872E+09 | 43471872.52 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318037E+09 | 52260770.61 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228425E+10 | 0.516716E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105337E+09 | 23758489.71 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318037E+09 | 67018297.09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300425E+09 | 67018297.09 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223673E+09 | 57331088.13 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171226E+09 | 62267329.46 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105337E+09 | 50891875.57 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111074E+09 | 39550237.89 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106337E+09 | 30201640.27 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118437E+09 | 24188655.98 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126717E+09 | 26985560.23 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164512E+09 | 23758489.71 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246603E+09 | 38790005.81 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291872E+09 | 43471872.52 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318037E+09 | 52260770.61 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228425E+10 | 0.516716E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105337E+09 | 23758489.71 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318037E+09 | 67018297.09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.358786E+09 | 79820551.21 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267128E+09 | 68247668.86 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.204375E+09 | 74128640.16 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.125599E+09 | 60629762.31 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132230E+09 | 47132327.39 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.126571E+09 | 36052082.36 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.140869E+09 | 28892530.66 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.150717E+09 | 32228869.64 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.196045E+09 | 28387219.87 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.294112E+09 | 46268794.26 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348406E+09 | 51854576.74 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.379786E+09 | 62294495.67 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.272462E+10 | 0.615938E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.125599E+09 | 28387219.87 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.379786E+09 | 79820551.21 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300484E+09 | 66841730.68 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223721E+09 | 57212923.19 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171262E+09 | 62181830.57 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105381E+09 | 50797574.73 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111071E+09 | 39663807.14 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106320E+09 | 30370479.05 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118372E+09 | 24527898.87 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126668E+09 | 27292856.14 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164421E+09 | 24173800.23 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246547E+09 | 39118996.35 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291873E+09 | 43557980.87 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318064E+09 | 52224344.97 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228418E+10 | 0.517964E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105381E+09 | 24173800.23 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318064E+09 | 66841730.68 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300484E+09 | 66841730.68 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223721E+09 | 57212923.19 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171262E+09 | 62181830.57 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105381E+09 | 50797574.73 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111071E+09 | 39663807.14 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106320E+09 | 30370479.05 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118372E+09 | 24527898.87 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126668E+09 | 27292856.14 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164421E+09 | 24173800.23 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246547E+09 | 39118996.35 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291873E+09 | 43557980.87 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318064E+09 | 52224344.97 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228418E+10 | 0.517964E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105381E+09 | 24173800.23 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318064E+09 | 66841730.68 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.358858E+09 | 79610586.54 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267185E+09 | 68107372.53 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.204419E+09 | 74026728.68 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.125651E+09 | 60518483.20 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132227E+09 | 47267518.02 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.126550E+09 | 36252776.13 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.140791E+09 | 29294996.74 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.150658E+09 | 32593283.04 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.195935E+09 | 28880660.16 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.294044E+09 | 46659604.91 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348407E+09 | 51955501.66 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.379819E+09 | 62250337.63 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.272454E+10 | 0.617418E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.125651E+09 | 28880660.16 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.379819E+09 | 79610586.54 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300771E+09 | 65938406.52 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224012E+09 | 56369702.09 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171578E+09 | 61233657.43 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105685E+09 | 49910509.00 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111375E+09 | 38829961.46 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106609E+09 | 29583630.36 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118647E+09 | 23763336.43 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126941E+09 | 26479239.89 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164663E+09 | 23415994.38 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246794E+09 | 38303223.95 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.292136E+09 | 42766985.64 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318343E+09 | 51354681.53 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228755E+10 | 0.507949E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105685E+09 | 23415994.38 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318343E+09 | 65938406.52 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300771E+09 | 65938406.52 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224012E+09 | 56369702.09 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171578E+09 | 61233657.43 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105685E+09 | 49910509.00 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111375E+09 | 38829961.46 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106609E+09 | 29583630.36 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118647E+09 | 23763336.43 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126941E+09 | 26479239.89 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164663E+09 | 23415994.38 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246794E+09 | 38303223.95 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.292136E+09 | 42766985.64 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318343E+09 | 51354681.53 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228755E+10 | 0.507949E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105685E+09 | 23415994.38 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318343E+09 | 65938406.52 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.359206E+09 | 78543001.68 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267539E+09 | 67112039.82 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.204801E+09 | 72906024.94 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.126019E+09 | 59469867.84 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132594E+09 | 46284519.58 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.126900E+09 | 35323468.04 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.141124E+09 | 28394087.90 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.150987E+09 | 31633899.29 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.196227E+09 | 27987233.08 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.294342E+09 | 45695693.90 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348725E+09 | 51021991.71 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.380156E+09 | 61222624.60 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.272862E+10 | 0.605594E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.126019E+09 | 27987233.08 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.380156E+09 | 78543001.68 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301004E+09 | 63319614.65 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224338E+09 | 53965353.41 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171834E+09 | 58549919.71 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105653E+09 | 47399509.48 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110934E+09 | 36297477.45 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105996E+09 | 27111505.63 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.117763E+09 | 21386626.09 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126130E+09 | 23876412.41 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164110E+09 | 21187365.74 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246361E+09 | 35868127.87 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291910E+09 | 40436026.25 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318374E+09 | 48823362.23 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228441E+10 | 0.478221E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105653E+09 | 21187365.74 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318374E+09 | 63319614.65 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301004E+09 | 63319614.65 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224338E+09 | 53965353.41 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171834E+09 | 58549919.71 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105653E+09 | 47399509.48 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110934E+09 | 36297477.45 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105996E+09 | 27111505.63 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.117763E+09 | 21386626.09 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126130E+09 | 23876412.41 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164110E+09 | 21187365.74 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246361E+09 | 35868127.87 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291910E+09 | 40436026.25 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318374E+09 | 48823362.23 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228441E+10 | 0.478221E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105653E+09 | 21187365.74 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318374E+09 | 63319614.65 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301004E+09 | 63319614.65 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224338E+09 | 53965353.41 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171834E+09 | 58549919.71 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105653E+09 | 47399509.48 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110934E+09 | 36297477.45 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105996E+09 | 27111505.63 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.117763E+09 | 21386626.09 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126130E+09 | 23876412.41 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164110E+09 | 21187365.74 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246361E+09 | 35868127.87 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291910E+09 | 40436026.25 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318374E+09 | 48823362.23 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228441E+10 | 0.478221E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105653E+09 | 21187365.74 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318374E+09 | 63319614.65 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301004E+09 | 63319614.65 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224338E+09 | 53965353.41 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.171834E+09 | 58549919.71 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.105653E+09 | 47399509.48 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.110934E+09 | 36297477.45 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.105996E+09 | 27111505.63 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.117763E+09 | 21386626.09 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126130E+09 | 23876412.41 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164110E+09 | 21187365.74 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246361E+09 | 35868127.87 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291910E+09 | 40436026.25 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318374E+09 | 48823362.23 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228441E+10 | 0.478221E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.105653E+09 | 21187365.74 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318374E+09 | 63319614.65 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.359498E+09 | 75435285.91 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267938E+09 | 64258169.20 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.205133E+09 | 69718292.23 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.126017E+09 | 56481916.48 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132116E+09 | 43276884.15 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.126224E+09 | 32387628.48 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.140131E+09 | 25571287.38 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.150083E+09 | 28538975.86 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.195605E+09 | 25329174.98 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.293858E+09 | 42795803.47 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348481E+09 | 48250927.48 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.380209E+09 | 58216612.14 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.272529E+10 | 0.570261E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.126017E+09 | 25329174.98 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.380209E+09 | 75435285.91 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.359498E+09 | 75435285.91 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267938E+09 | 64258169.20 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.205133E+09 | 69718292.23 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.126017E+09 | 56481916.48 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132116E+09 | 43276884.15 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.126224E+09 | 32387628.48 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.140131E+09 | 25571287.38 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.150083E+09 | 28538975.86 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.195605E+09 | 25329174.98 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.293858E+09 | 42795803.47 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348481E+09 | 48250927.48 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.380209E+09 | 58216612.14 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.272529E+10 | 0.570261E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.126017E+09 | 25329174.98 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.380209E+09 | 75435285.91 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300881E+09 | 62532809.55 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224315E+09 | 53222382.56 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.172063E+09 | 57714621.92 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.106043E+09 | 46583705.52 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111550E+09 | 35400621.44 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106652E+09 | 26146341.70 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118573E+09 | 20360425.29 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126949E+09 | 22820384.98 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164746E+09 | 20132482.79 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246748E+09 | 34829796.94 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291990E+09 | 39465951.56 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318271E+09 | 47884173.73 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228878E+10 | 0.467094E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.106043E+09 | 20132482.79 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318271E+09 | 62532809.55 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.300881E+09 | 62532809.55 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224315E+09 | 53222382.56 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.172063E+09 | 57714621.92 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.106043E+09 | 46583705.52 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111550E+09 | 35400621.44 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106652E+09 | 26146341.70 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118573E+09 | 20360425.29 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126949E+09 | 22820384.98 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164746E+09 | 20132482.79 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246748E+09 | 34829796.94 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.291990E+09 | 39465951.56 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318271E+09 | 47884173.73 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228878E+10 | 0.467094E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.106043E+09 | 20132482.79 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318271E+09 | 62532809.55 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.359398E+09 | 74496342.64 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267950E+09 | 63370119.15 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.205430E+09 | 68719394.54 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.126496E+09 | 55510304.84 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132861E+09 | 42210062.35 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.127015E+09 | 31242767.88 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.141102E+09 | 24355684.78 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.151061E+09 | 27288332.88 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.196376E+09 | 24079231.18 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.294345E+09 | 41563694.59 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348615E+09 | 47096910.42 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.380136E+09 | 57096797.46 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.273078E+10 | 0.557030E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.126496E+09 | 24079231.18 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.380136E+09 | 74496342.64 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301012E+09 | 62270167.16 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224446E+09 | 52968415.02 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.172197E+09 | 57442289.62 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.106165E+09 | 46347531.06 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111680E+09 | 35191009.06 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106784E+09 | 25948753.76 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118703E+09 | 20168654.75 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.127067E+09 | 22635827.38 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164861E+09 | 19937751.48 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246861E+09 | 34622236.93 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.292117E+09 | 39234577.63 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318404E+09 | 47627632.20 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.229030E+10 | 0.464395E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.106165E+09 | 19937751.48 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318404E+09 | 62270167.16 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301012E+09 | 62270167.16 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224446E+09 | 52968415.02 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.172197E+09 | 57442289.62 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.106165E+09 | 46347531.06 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111680E+09 | 35191009.06 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106784E+09 | 25948753.76 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118703E+09 | 20168654.75 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.127067E+09 | 22635827.38 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164861E+09 | 19937751.48 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246861E+09 | 34622236.93 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.292117E+09 | 39234577.63 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318404E+09 | 47627632.20 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.229030E+10 | 0.464395E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.106165E+09 | 19937751.48 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318404E+09 | 62270167.16 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.359557E+09 | 74183447.67 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.268108E+09 | 63068110.24 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.205592E+09 | 68395637.91 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.126643E+09 | 55229935.72 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.133018E+09 | 41961110.20 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.127173E+09 | 31008131.25 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.141260E+09 | 24127604.91 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.151204E+09 | 27068527.61 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.196516E+09 | 23847510.32 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.294480E+09 | 41316484.96 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348769E+09 | 46821653.09 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.380297E+09 | 56791786.81 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.273262E+10 | 0.553820E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.126643E+09 | 23847510.32 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.380297E+09 | 74183447.67 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301112E+09 | 61875829.44 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224557E+09 | 52558597.05 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.172261E+09 | 57042151.84 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.106164E+09 | 46066418.93 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111592E+09 | 35089872.20 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106683E+09 | 25885760.27 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118535E+09 | 20214076.89 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126867E+09 | 22723394.74 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164706E+09 | 20001597.07 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246729E+09 | 34644068.56 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.292127E+09 | 39057329.04 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318462E+09 | 47341613.80 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228980E+10 | 0.462501E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.106164E+09 | 20001597.07 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318462E+09 | 61875829.44 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.301112E+09 | 61875829.44 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.224557E+09 | 52558597.05 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.172261E+09 | 57042151.84 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.106164E+09 | 46066418.93 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.111592E+09 | 35089872.20 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.106683E+09 | 25885760.27 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.118535E+09 | 20214076.89 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.126867E+09 | 22723394.74 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.164706E+09 | 20001597.07 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.246729E+09 | 34644068.56 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.292127E+09 | 39057329.04 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.318462E+09 | 47341613.80 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.228980E+10 | 0.462501E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.106164E+09 | 20001597.07 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.318462E+09 | 61875829.44 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.359676E+09 | 73719335.06 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.268241E+09 | 62586836.39 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.205669E+09 | 67927002.99 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.126642E+09 | 54903239.65 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.132910E+09 | 41848357.28 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.127051E+09 | 30940824.15 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.141056E+09 | 24189455.82 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.150960E+09 | 27180852.72 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.196328E+09 | 23931201.03 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.294321E+09 | 41350559.61 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.348779E+09 | 46618392.35 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.380365E+09 | 56459456.53 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.273200E+10 | 0.551656E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.126642E+09 | 23931201.03 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.380365E+09 | 73719335.06 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.299961E+09 | 60876605.15 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223712E+09 | 51473460.02 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.170951E+09 | 55993332.37 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.104339E+09 | 45512502.87 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.108987E+09 | 35441568.57 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.104108E+09 | 26465720.36 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.115492E+09 | 21396207.85 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.123615E+09 | 24150078.36 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.162200E+09 | 21389885.95 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.244102E+09 | 35839165.44 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.290479E+09 | 39232676.06 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.317091E+09 | 46996305.01 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.226504E+10 | 0.464768E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.104108E+09 | 21389885.95 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.317091E+09 | 60876605.15 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178868E+09 | 0.112323E+09 | 66544612.83 | 0.299961E+09 | 60876605.15 |
February | 0.136846E+09 | 72948856.55 | 63897306.25 | 0.223712E+09 | 51473460.02 |
March | 0.109914E+09 | 37658250.00 | 72255443.68 | 0.170951E+09 | 55993332.37 |
April | 68779317.40 | 6623990.07 | 62155327.33 | 0.104339E+09 | 45512502.87 |
May | 60159217.62 | 155328.86 | 60003888.76 | 0.108987E+09 | 35441568.57 |
June | 57587790.40 | 0.00 | 57587790.40 | 0.104108E+09 | 26465720.36 |
July | 57700733.23 | 157743.04 | 57542990.18 | 0.115492E+09 | 21396207.85 |
August | 63119710.07 | 3876195.88 | 59243514.19 | 0.123615E+09 | 24150078.36 |
September | 92313211.60 | 22403605.13 | 69909606.48 | 0.162200E+09 | 21389885.95 |
October | 0.135238E+09 | 65307950.34 | 69929903.65 | 0.244102E+09 | 35839165.44 |
November | 0.165256E+09 | 94730964.45 | 70525414.76 | 0.290479E+09 | 39232676.06 |
December | 0.184782E+09 | 0.119059E+09 | 65722076.61 | 0.317091E+09 | 46996305.01 |
Annual Sum or Average | 0.131056E+10 | 0.535245E+09 | 0.775318E+09 | 0.226504E+10 | 0.464768E+09 |
Minimum of Months | 57587790.40 | 0.00 | 57542990.18 | 0.104108E+09 | 21389885.95 |
Maximum of Months | 0.184782E+09 | 0.119059E+09 | 72255443.68 | 0.317091E+09 | 60876605.15 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214171E+09 | 0.134492E+09 | 79678418.00 | 0.358269E+09 | 72545043.28 |
February | 0.163855E+09 | 87346657.18 | 76508616.69 | 0.267213E+09 | 61306412.64 |
March | 0.131607E+09 | 45090799.34 | 86516386.51 | 0.204080E+09 | 66693370.01 |
April | 82354182.68 | 7931356.53 | 74422826.15 | 0.124430E+09 | 54255993.69 |
May | 72032747.41 | 185985.87 | 71846761.54 | 0.129755E+09 | 42273965.56 |
June | 68953801.66 | 0.00 | 68953801.66 | 0.123932E+09 | 31638831.48 |
July | 69089035.84 | 188876.54 | 68900159.30 | 0.137373E+09 | 25601018.42 |
August | 75577547.59 | 4641234.54 | 70936313.05 | 0.147024E+09 | 28882861.42 |
September | 0.110533E+09 | 26825369.29 | 83707555.12 | 0.193298E+09 | 25587594.86 |
October | 0.161930E+09 | 78197677.38 | 83731858.32 | 0.291135E+09 | 42779053.20 |
November | 0.197873E+09 | 0.113428E+09 | 84444904.52 | 0.346777E+09 | 46837439.64 |
December | 0.221252E+09 | 0.142558E+09 | 78693539.10 | 0.378696E+09 | 56061266.27 |
Annual Sum or Average | 0.156923E+10 | 0.640886E+09 | 0.928341E+09 | 0.270198E+10 | 0.554463E+09 |
Minimum of Months | 68953801.66 | 0.00 | 68900159.30 | 0.123932E+09 | 25587594.86 |
Maximum of Months | 0.221252E+09 | 0.142558E+09 | 86516386.51 | 0.378696E+09 | 72545043.28 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 718.59 | 149.21 | 427.93 | 268.73 | 159.20 | 0.00 | 0.00 |
February | 592.42 | 141.10 | 362.47 | 193.22 | 169.25 | 0.00 | 0.00 |
March | 409.53 | 138.74 | 262.96 | 90.09 | 172.87 | 0.00 | 0.00 |
April | 259.53 | 115.77 | 170.03 | 16.38 | 153.66 | 0.00 | 0.00 |
May | 264.24 | 83.43 | 143.93 | 0.37 | 143.56 | 0.00 | 0.00 |
June | 260.77 | 63.69 | 142.37 | 0.00 | 142.37 | 0.00 | 0.00 |
July | 281.81 | 45.96 | 138.05 | 0.38 | 137.67 | 0.00 | 0.00 |
August | 300.32 | 53.12 | 151.01 | 9.27 | 141.74 | 0.00 | 0.00 |
September | 406.24 | 47.47 | 228.22 | 55.39 | 172.83 | 0.00 | 0.00 |
October | 589.02 | 79.80 | 323.55 | 156.24 | 167.30 | 0.00 | 0.00 |
November | 720.06 | 95.90 | 408.54 | 234.19 | 174.35 | 0.00 | 0.00 |
December | 760.12 | 113.34 | 442.08 | 284.84 | 157.24 | 0.00 | 0.00 |
Annual Sum or Average | 463.06 | 93.72 | 266.30 | 108.76 | 157.54 | 0.00 | 0.00 |
Minimum of Months | 259.53 | 45.96 | 138.05 | 0.00 | 137.67 | 0.00 | 0.00 |
Maximum of Months | 760.12 | 149.21 | 442.08 | 284.84 | 174.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 358.73 | 75.50 | 213.96 | 134.36 | 79.60 | 0.00 | 0.00 |
February | 295.98 | 71.24 | 181.24 | 96.61 | 84.62 | 0.00 | 0.00 |
March | 204.99 | 70.03 | 131.48 | 45.05 | 86.43 | 0.00 | 0.00 |
April | 130.22 | 58.33 | 85.02 | 8.19 | 76.83 | 0.00 | 0.00 |
May | 133.02 | 41.88 | 71.96 | 0.19 | 71.78 | 0.00 | 0.00 |
June | 131.52 | 31.63 | 71.18 | 0.00 | 71.18 | 0.00 | 0.00 |
July | 142.44 | 22.56 | 69.02 | 0.19 | 68.83 | 0.00 | 0.00 |
August | 151.83 | 26.01 | 75.50 | 4.64 | 70.87 | 0.00 | 0.00 |
September | 204.80 | 23.01 | 114.11 | 27.69 | 86.41 | 0.00 | 0.00 |
October | 295.35 | 39.80 | 161.77 | 78.12 | 83.65 | 0.00 | 0.00 |
November | 360.16 | 47.97 | 204.27 | 117.10 | 87.18 | 0.00 | 0.00 |
December | 379.71 | 57.09 | 221.04 | 142.42 | 78.62 | 0.00 | 0.00 |
Annual Sum or Average | 232.15 | 46.97 | 133.15 | 54.38 | 78.77 | 0.00 | 0.00 |
Minimum of Months | 130.22 | 22.56 | 69.02 | 0.00 | 68.83 | 0.00 | 0.00 |
Maximum of Months | 379.71 | 75.50 | 221.04 | 142.42 | 87.18 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 358.29 | 79.85 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 295.33 | 75.61 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 204.16 | 74.17 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 129.74 | 62.66 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 132.31 | 47.13 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 130.88 | 37.21 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 141.03 | 28.85 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 150.89 | 32.18 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 202.57 | 29.28 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 293.95 | 46.24 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 359.63 | 53.55 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 379.28 | 62.28 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 231.26 | 52.30 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 129.74 | 28.85 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 379.28 | 79.85 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 358.36 | 79.63 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 295.40 | 75.45 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 204.20 | 74.07 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 129.79 | 62.54 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 132.31 | 47.27 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 130.86 | 37.42 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 140.96 | 29.25 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 150.83 | 32.55 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 202.46 | 29.79 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 293.88 | 46.63 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 359.63 | 53.65 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 379.31 | 62.24 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 231.26 | 52.43 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 129.79 | 29.25 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 379.31 | 79.63 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 358.70 | 78.56 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 295.79 | 74.34 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 204.58 | 72.94 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 130.17 | 61.45 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 132.67 | 46.28 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 131.22 | 36.45 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 141.29 | 28.35 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 151.16 | 31.58 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 202.76 | 28.87 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 294.18 | 45.66 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 359.95 | 52.68 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 379.65 | 61.21 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 231.60 | 51.42 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 130.17 | 28.35 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 379.65 | 78.56 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 717.97 | 150.89 | 427.05 | 268.17 | 158.88 | 0.00 | 0.00 |
February | 592.44 | 142.35 | 361.73 | 192.83 | 168.90 | 0.00 | 0.00 |
March | 409.80 | 139.50 | 262.42 | 89.91 | 172.51 | 0.00 | 0.00 |
April | 260.28 | 116.73 | 169.69 | 16.34 | 153.34 | 0.00 | 0.00 |
May | 264.33 | 86.52 | 143.63 | 0.37 | 143.26 | 0.00 | 0.00 |
June | 260.97 | 66.83 | 142.08 | 0.00 | 142.08 | 0.00 | 0.00 |
July | 280.51 | 51.03 | 137.76 | 0.38 | 137.39 | 0.00 | 0.00 |
August | 300.44 | 56.97 | 150.70 | 9.25 | 141.45 | 0.00 | 0.00 |
September | 404.19 | 52.24 | 227.75 | 55.27 | 172.47 | 0.00 | 0.00 |
October | 587.35 | 85.52 | 322.88 | 155.92 | 166.96 | 0.00 | 0.00 |
November | 719.37 | 99.63 | 407.70 | 233.71 | 173.99 | 0.00 | 0.00 |
December | 759.38 | 116.39 | 441.17 | 284.26 | 156.91 | 0.00 | 0.00 |
Annual Sum or Average | 462.59 | 96.82 | 265.75 | 108.53 | 157.22 | 0.00 | 0.00 |
Minimum of Months | 260.28 | 51.03 | 137.76 | 0.00 | 137.39 | 0.00 | 0.00 |
Maximum of Months | 759.38 | 150.89 | 441.17 | 284.26 | 173.99 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 358.86 | 74.51 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 296.21 | 70.19 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 205.18 | 68.75 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 130.63 | 57.36 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 132.90 | 42.19 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 131.30 | 32.23 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 141.22 | 24.30 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 151.19 | 27.23 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 202.88 | 24.82 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 294.15 | 41.53 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 359.80 | 48.62 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 379.58 | 57.07 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 231.75 | 47.29 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 130.63 | 24.30 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 379.58 | 74.51 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 359.01 | 74.19 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 296.38 | 69.86 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 205.34 | 68.43 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 130.78 | 57.07 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 133.06 | 41.94 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 131.46 | 31.99 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 141.38 | 24.07 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 151.34 | 27.01 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 203.02 | 24.58 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 294.28 | 41.28 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 359.96 | 48.34 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 379.74 | 56.77 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 231.90 | 47.01 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 130.78 | 24.07 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 379.74 | 74.19 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 359.13 | 73.73 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 296.53 | 69.32 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 205.42 | 67.96 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 130.78 | 56.73 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 132.95 | 41.83 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 131.33 | 31.91 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 141.18 | 24.13 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 151.10 | 27.12 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 202.83 | 24.67 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 294.12 | 41.31 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 359.97 | 48.12 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 379.81 | 56.43 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 231.85 | 46.82 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 130.78 | 24.13 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 379.81 | 73.73 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 357.75 | 72.54 | 213.53 | 134.09 | 79.44 | 0.00 | 0.00 |
February | 295.40 | 67.90 | 180.86 | 96.41 | 84.45 | 0.00 | 0.00 |
March | 203.85 | 66.71 | 131.21 | 44.95 | 86.26 | 0.00 | 0.00 |
April | 128.51 | 56.05 | 84.84 | 8.17 | 76.67 | 0.00 | 0.00 |
May | 129.83 | 42.25 | 71.82 | 0.19 | 71.63 | 0.00 | 0.00 |
June | 128.14 | 32.63 | 71.04 | 0.00 | 71.04 | 0.00 | 0.00 |
July | 137.53 | 25.54 | 68.88 | 0.19 | 68.69 | 0.00 | 0.00 |
August | 147.20 | 28.82 | 75.35 | 4.63 | 70.72 | 0.00 | 0.00 |
September | 199.73 | 26.38 | 113.87 | 27.64 | 86.24 | 0.00 | 0.00 |
October | 290.97 | 42.73 | 161.44 | 77.96 | 83.48 | 0.00 | 0.00 |
November | 357.92 | 48.34 | 203.85 | 116.86 | 87.00 | 0.00 | 0.00 |
December | 378.17 | 56.02 | 220.58 | 142.13 | 78.46 | 0.00 | 0.00 |
Annual Sum or Average | 229.33 | 47.06 | 132.88 | 54.27 | 78.61 | 0.00 | 0.00 |
Minimum of Months | 128.14 | 25.54 | 68.88 | 0.00 | 68.69 | 0.00 | 0.00 |
Maximum of Months | 378.17 | 72.54 | 220.58 | 142.13 | 87.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.192467E+10 | 0.399641E+09 | 0.114617E+10 | 0.719755E+09 | 0.426411E+09 | 0.00 | 0.00 |
February | 0.143319E+10 | 0.341339E+09 | 0.876896E+09 | 0.467449E+09 | 0.409447E+09 | 0.00 | 0.00 |
March | 0.109688E+10 | 0.371590E+09 | 0.704315E+09 | 0.241310E+09 | 0.463005E+09 | 0.00 | 0.00 |
April | 0.672710E+09 | 0.300071E+09 | 0.440731E+09 | 42445831.10 | 0.398285E+09 | 0.00 | 0.00 |
May | 0.707746E+09 | 0.223450E+09 | 0.385494E+09 | 995330.98 | 0.384499E+09 | 0.00 | 0.00 |
June | 0.675920E+09 | 0.165075E+09 | 0.369016E+09 | 0.00 | 0.369016E+09 | 0.00 | 0.00 |
July | 0.754789E+09 | 0.123107E+09 | 0.369740E+09 | 1010800.82 | 0.368729E+09 | 0.00 | 0.00 |
August | 0.804366E+09 | 0.142276E+09 | 0.404464E+09 | 24838255.19 | 0.379626E+09 | 0.00 | 0.00 |
September | 0.105298E+10 | 0.123052E+09 | 0.591533E+09 | 0.143560E+09 | 0.447973E+09 | 0.00 | 0.00 |
October | 0.157764E+10 | 0.213723E+09 | 0.866590E+09 | 0.418486E+09 | 0.448103E+09 | 0.00 | 0.00 |
November | 0.186638E+10 | 0.248568E+09 | 0.105895E+10 | 0.607026E+09 | 0.451919E+09 | 0.00 | 0.00 |
December | 0.203590E+10 | 0.303572E+09 | 0.118406E+10 | 0.762920E+09 | 0.421140E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.146032E+11 | 0.295546E+10 | 0.839795E+10 | 0.342980E+10 | 0.496816E+10 | 0.00 | 0.00 |
Minimum of Months | 0.672710E+09 | 0.123052E+09 | 0.369016E+09 | 0.00 | 0.368729E+09 | 0.00 | 0.00 |
Maximum of Months | 0.203590E+10 | 0.399641E+09 | 0.118406E+10 | 0.762920E+09 | 0.463005E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.960819E+09 | 0.202232E+09 | 0.573083E+09 | 0.359877E+09 | 0.213205E+09 | 0.00 | 0.00 |
February | 0.716041E+09 | 0.172340E+09 | 0.438448E+09 | 0.233724E+09 | 0.204724E+09 | 0.00 | 0.00 |
March | 0.549049E+09 | 0.187569E+09 | 0.352158E+09 | 0.120655E+09 | 0.231503E+09 | 0.00 | 0.00 |
April | 0.337543E+09 | 0.151201E+09 | 0.220365E+09 | 21222915.55 | 0.199142E+09 | 0.00 | 0.00 |
May | 0.356268E+09 | 0.112167E+09 | 0.192747E+09 | 497665.49 | 0.192249E+09 | 0.00 | 0.00 |
June | 0.340893E+09 | 81988965.38 | 0.184508E+09 | 0.00 | 0.184508E+09 | 0.00 | 0.00 |
July | 0.381515E+09 | 60415225.67 | 0.184870E+09 | 505400.41 | 0.184365E+09 | 0.00 | 0.00 |
August | 0.406650E+09 | 69678240.00 | 0.202232E+09 | 12419127.59 | 0.189813E+09 | 0.00 | 0.00 |
September | 0.530852E+09 | 59643476.51 | 0.295767E+09 | 71779971.68 | 0.223987E+09 | 0.00 | 0.00 |
October | 0.791055E+09 | 0.106604E+09 | 0.433295E+09 | 0.209243E+09 | 0.224052E+09 | 0.00 | 0.00 |
November | 0.933525E+09 | 0.124339E+09 | 0.529473E+09 | 0.303513E+09 | 0.225960E+09 | 0.00 | 0.00 |
December | 0.101701E+10 | 0.152911E+09 | 0.592030E+09 | 0.381460E+09 | 0.210570E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.732122E+10 | 0.148109E+10 | 0.419898E+10 | 0.171490E+10 | 0.248408E+10 | 0.00 | 0.00 |
Minimum of Months | 0.337543E+09 | 59643476.51 | 0.184508E+09 | 0.00 | 0.184365E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101701E+10 | 0.202232E+09 | 0.592030E+09 | 0.381460E+09 | 0.231503E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.959637E+09 | 0.213857E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.714474E+09 | 0.182910E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.546828E+09 | 0.198663E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.336274E+09 | 0.162413E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.354378E+09 | 0.126233E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.339245E+09 | 96455358.62 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.377742E+09 | 77269748.79 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.404150E+09 | 86199823.05 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.525069E+09 | 75904036.60 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.787319E+09 | 0.123848E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.932149E+09 | 0.138798E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101586E+10 | 0.166816E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.729313E+10 | 0.164937E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.336274E+09 | 75904036.60 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101586E+10 | 0.213857E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.959827E+09 | 0.213294E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.714627E+09 | 0.182533E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.546943E+09 | 0.198390E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.336413E+09 | 0.162114E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.354369E+09 | 0.126595E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.339189E+09 | 96993718.32 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.377534E+09 | 78350704.63 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.403993E+09 | 87178850.99 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.524776E+09 | 77228121.09 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.787137E+09 | 0.124897E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.932153E+09 | 0.139071E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101595E+10 | 0.166699E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.729291E+10 | 0.165334E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.336413E+09 | 77228121.09 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101595E+10 | 0.213294E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.960748E+09 | 0.210420E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.715563E+09 | 0.179851E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.547956E+09 | 0.195373E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.337389E+09 | 0.159291E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.355343E+09 | 0.123944E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.340118E+09 | 94490533.38 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.378418E+09 | 75920730.92 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.404868E+09 | 84592379.07 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.525554E+09 | 74819195.14 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.787931E+09 | 0.122302E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.932996E+09 | 0.136556E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101684E+10 | 0.163932E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.730373E+10 | 0.162149E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.337389E+09 | 74819195.14 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101684E+10 | 0.210420E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.192301E+10 | 0.404149E+09 | 0.114381E+10 | 0.718277E+09 | 0.425535E+09 | 0.00 | 0.00 |
February | 0.143323E+10 | 0.344378E+09 | 0.875095E+09 | 0.466489E+09 | 0.408606E+09 | 0.00 | 0.00 |
March | 0.109760E+10 | 0.373636E+09 | 0.702869E+09 | 0.240815E+09 | 0.462055E+09 | 0.00 | 0.00 |
April | 0.674646E+09 | 0.302562E+09 | 0.439826E+09 | 42358673.34 | 0.397467E+09 | 0.00 | 0.00 |
May | 0.707969E+09 | 0.231744E+09 | 0.384702E+09 | 993287.18 | 0.383709E+09 | 0.00 | 0.00 |
June | 0.676430E+09 | 0.173221E+09 | 0.368259E+09 | 0.00 | 0.368259E+09 | 0.00 | 0.00 |
July | 0.751316E+09 | 0.136689E+09 | 0.368981E+09 | 1008725.26 | 0.367972E+09 | 0.00 | 0.00 |
August | 0.804685E+09 | 0.152583E+09 | 0.403634E+09 | 24787252.61 | 0.378847E+09 | 0.00 | 0.00 |
September | 0.104765E+10 | 0.135408E+09 | 0.590319E+09 | 0.143265E+09 | 0.447054E+09 | 0.00 | 0.00 |
October | 0.157316E+10 | 0.229064E+09 | 0.864810E+09 | 0.417627E+09 | 0.447183E+09 | 0.00 | 0.00 |
November | 0.186460E+10 | 0.258246E+09 | 0.105677E+10 | 0.605780E+09 | 0.450991E+09 | 0.00 | 0.00 |
December | 0.203391E+10 | 0.311726E+09 | 0.118163E+10 | 0.761354E+09 | 0.420275E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.145882E+11 | 0.305340E+10 | 0.838071E+10 | 0.342275E+10 | 0.495795E+10 | 0.00 | 0.00 |
Minimum of Months | 0.674646E+09 | 0.135408E+09 | 0.368259E+09 | 0.00 | 0.367972E+09 | 0.00 | 0.00 |
Maximum of Months | 0.203391E+10 | 0.404149E+09 | 0.118163E+10 | 0.761354E+09 | 0.462055E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.961159E+09 | 0.199562E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.716579E+09 | 0.169815E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.549556E+09 | 0.184149E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.338581E+09 | 0.148678E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.355961E+09 | 0.113011E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.340320E+09 | 83535233.03 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.378247E+09 | 65076535.35 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.404959E+09 | 72928966.55 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.525867E+09 | 64344161.93 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.787841E+09 | 0.111223E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.932595E+09 | 0.126029E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101668E+10 | 0.152865E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.730834E+10 | 0.149122E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.338581E+09 | 64344161.93 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101668E+10 | 0.199562E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.961581E+09 | 0.198724E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.717001E+09 | 0.169005E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.549986E+09 | 0.183280E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.338973E+09 | 0.147925E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.356378E+09 | 0.112343E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.340741E+09 | 82905588.26 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.378666E+09 | 64464812.94 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.405338E+09 | 72339761.06 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.526239E+09 | 63722967.03 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.788201E+09 | 0.110561E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.933003E+09 | 0.125291E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101710E+10 | 0.152047E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.731321E+10 | 0.148261E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.338973E+09 | 63722967.03 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101710E+10 | 0.198724E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.961901E+09 | 0.197471E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.717355E+09 | 0.167704E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.550191E+09 | 0.182011E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.338971E+09 | 0.147036E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.356094E+09 | 0.112028E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.340418E+09 | 82712089.57 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.378127E+09 | 64617591.69 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.404695E+09 | 72627541.97 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.525739E+09 | 63934349.05 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.787778E+09 | 0.110638E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.933032E+09 | 0.124733E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101729E+10 | 0.151143E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.731159E+10 | 0.147666E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.338971E+09 | 63934349.05 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101729E+10 | 0.197471E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.958190E+09 | 0.194298E+09 | 0.571906E+09 | 0.359138E+09 | 0.212768E+09 | 0.00 | 0.00 |
February | 0.714636E+09 | 0.164253E+09 | 0.437548E+09 | 0.233244E+09 | 0.204303E+09 | 0.00 | 0.00 |
March | 0.545982E+09 | 0.178680E+09 | 0.351435E+09 | 0.120407E+09 | 0.231027E+09 | 0.00 | 0.00 |
April | 0.333107E+09 | 0.145281E+09 | 0.219913E+09 | 21179336.67 | 0.198733E+09 | 0.00 | 0.00 |
May | 0.347728E+09 | 0.113157E+09 | 0.192351E+09 | 496643.59 | 0.191855E+09 | 0.00 | 0.00 |
June | 0.332149E+09 | 84570272.19 | 0.184129E+09 | 0.00 | 0.184129E+09 | 0.00 | 0.00 |
July | 0.368356E+09 | 68393238.24 | 0.184491E+09 | 504362.63 | 0.183986E+09 | 0.00 | 0.00 |
August | 0.394254E+09 | 77182989.29 | 0.201817E+09 | 12393626.30 | 0.189423E+09 | 0.00 | 0.00 |
September | 0.517697E+09 | 68367046.64 | 0.295159E+09 | 71632579.55 | 0.223527E+09 | 0.00 | 0.00 |
October | 0.779338E+09 | 0.114457E+09 | 0.432405E+09 | 0.208814E+09 | 0.223592E+09 | 0.00 | 0.00 |
November | 0.927735E+09 | 0.125303E+09 | 0.528386E+09 | 0.302890E+09 | 0.225496E+09 | 0.00 | 0.00 |
December | 0.101288E+10 | 0.150054E+09 | 0.590815E+09 | 0.380677E+09 | 0.210138E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.723205E+10 | 0.148400E+10 | 0.419035E+10 | 0.171138E+10 | 0.247898E+10 | 0.00 | 0.00 |
Minimum of Months | 0.332149E+09 | 68367046.64 | 0.184129E+09 | 0.00 | 0.183986E+09 | 0.00 | 0.00 |
Maximum of Months | 0.101288E+10 | 0.194298E+09 | 0.590815E+09 | 0.380677E+09 | 0.231027E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 22.49 | 18.25 | 15.90 | 4.15 | 13.31 | 59.87 | 181.51 | 0.00 |
February | 22.80 | 19.74 | 18.20 | 3.70 | 14.21 | 74.30 | 182.84 | 0.03 |
March | 23.17 | 18.99 | 16.85 | 4.23 | 14.23 | 89.51 | 186.76 | 0.02 |
April | 23.76 | 19.01 | 16.50 | 4.83 | 14.94 | 95.22 | 199.35 | 0.00 |
May | 25.23 | 20.49 | 18.23 | 4.38 | 17.08 | 98.73 | 213.00 | 0.00 |
June | 25.87 | 20.89 | 18.70 | 5.87 | 17.20 | 99.16 | 227.55 | 0.00 |
July | 26.90 | 21.77 | 19.49 | 5.98 | 18.80 | 89.26 | 241.04 | 0.00 |
August | 27.06 | 21.88 | 19.61 | 5.21 | 18.26 | 83.09 | 253.22 | 0.00 |
September | 26.87 | 22.30 | 20.37 | 5.44 | 18.71 | 93.82 | 214.78 | 0.00 |
October | 26.22 | 21.67 | 19.68 | 3.78 | 17.26 | 74.41 | 199.79 | 0.00 |
November | 24.76 | 20.57 | 18.62 | 5.17 | 16.20 | 67.97 | 175.93 | 0.00 |
December | 23.69 | 19.64 | 17.67 | 4.42 | 14.96 | 56.37 | 177.80 | 0.00 |
Annual Sum or Average | 24.91 | 20.44 | 18.32 | 4.77 | 16.27 | 81.79 | 204.64 | 0.00 |
Minimum of Months | 22.49 | 18.25 | 15.90 | 3.70 | 13.31 | 56.37 | 175.93 | 0.00 |
Maximum of Months | 27.06 | 22.30 | 20.37 | 5.98 | 18.80 | 99.16 | 253.22 | 0.03 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 29.40 | 03-JAN-12:00 | 22.05 | 18.90 | 3.60 | 19.35 | 145.50 | 575.00 |
February | 28.90 | 19-FEB-10:00 | 22.34 | 19.40 | 3.10 | 18.28 | 204.00 | 595.50 |
March | 30.00 | 29-MAR-12:00 | 20.05 | 15.00 | 6.70 | 20.22 | 350.50 | 543.50 |
April | 30.00 | 09-APR-13:00 | 20.06 | 15.00 | 7.20 | 17.39 | 126.00 | 778.50 |
May | 31.10 | 17-MAY-13:20 | 21.31 | 16.70 | 7.87 | 22.12 | 283.17 | 716.50 |
June | 30.60 | 26-JUN-13:00 | 21.72 | 17.80 | 6.70 | 20.40 | 162.00 | 756.50 |
July | 32.20 | 09-JUL-11:00 | 23.42 | 20.00 | 6.20 | 23.49 | 235.00 | 733.00 |
August | 32.80 | 11-AUG-13:00 | 23.28 | 19.40 | 6.20 | 23.99 | 228.00 | 563.00 |
September | 33.30 | 02-SEP-12:00 | 23.47 | 19.40 | 5.70 | 23.32 | 185.00 | 789.00 |
October | 33.30 | 01-OCT-12:00 | 23.04 | 18.90 | 6.20 | 23.15 | 143.50 | 854.50 |
November | 30.60 | 03-NOV-12:00 | 22.49 | 18.90 | 7.70 | 20.57 | 148.00 | 798.50 |
December | 30.60 | 13-DEC-13:00 | 22.11 | 18.30 | 5.70 | 18.64 | 59.00 | 832.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 28.90 | 20.05 | 15.00 | 3.10 | 17.39 | 59.00 | 543.50 | |
Maximum of Months | 33.30 | 23.47 | 20.00 | 7.87 | 23.99 | 350.50 | 854.50 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 17.20 | 07-JAN-06:00 | 15.82 | 15.00 | 1.50 | 3.89 | 0.00 | 0.00 |
February | 13.30 | 12-FEB-06:00 | 12.64 | 12.20 | 3.10 | 0.73 | 0.00 | 0.00 |
March | 15.00 | 08-MAR-03:00 | 13.29 | 12.20 | 0.00 | 1.16 | 0.00 | 0.00 |
April | 17.80 | 22-APR-02:00 | 16.39 | 15.60 | 0.00 | 6.75 | 0.00 | 0.00 |
May | 18.90 | 23-MAY-05:00 | 17.45 | 16.70 | 2.10 | 9.33 | 110.00 | 159.50 |
June | 21.10 | 06-JUN-04:00 | 19.20 | 18.30 | 2.60 | 9.52 | 0.00 | 0.00 |
July | 22.20 | 09-JUL-03:00 | 20.00 | 18.90 | 1.50 | 11.84 | 0.00 | 0.00 |
August | 21.10 | 18-AUG-05:00 | 19.93 | 19.40 | 2.10 | 8.54 | 0.00 | 0.00 |
September | 22.20 | 19-SEP-04:00 | 20.25 | 19.40 | 2.60 | 11.84 | 0.00 | 0.00 |
October | 19.40 | 19-OCT-05:00 | 17.58 | 16.70 | 2.60 | 9.33 | 0.00 | 0.00 |
November | 16.10 | 27-NOV-06:00 | 15.39 | 15.00 | 2.60 | 5.74 | 50.00 | 566.00 |
December | 16.70 | 26-DEC-01:00 | 15.01 | 13.90 | 2.60 | 4.31 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 13.30 | 12.64 | 12.20 | 0.00 | 0.73 | 0.00 | 0.00 | |
Maximum of Months | 22.20 | 20.25 | 19.40 | 3.10 | 11.84 | 110.00 | 566.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 23.03 | 01-JAN-15:00 | 27.80 | 21.10 | 4.10 | 20.92 | 91.00 | 199.00 |
February | 24.57 | 18-FEB-13:00 | 27.80 | 23.30 | 4.10 | 21.44 | 268.00 | 307.00 |
March | 23.81 | 13-MAR-12:00 | 27.80 | 22.20 | 5.70 | 22.47 | 468.50 | 259.00 |
April | 22.82 | 24-APR-11:00 | 28.30 | 20.60 | 4.60 | 19.87 | 357.00 | 446.00 |
May | 23.35 | 08-MAY-15:00 | 28.90 | 21.10 | 6.20 | 22.13 | 182.00 | 323.50 |
June | 23.02 | 20-JUN-13:00 | 28.90 | 20.60 | 7.70 | 21.96 | 370.50 | 346.50 |
July | 24.68 | 20-JUL-13:00 | 26.70 | 23.90 | 8.20 | 25.33 | 309.00 | 14.00 |
August | 25.47 | 19-AUG-14:00 | 31.70 | 23.30 | 5.20 | 25.33 | 229.00 | 409.00 |
September | 25.16 | 23-SEP-14:00 | 27.20 | 24.40 | 4.10 | 23.82 | 288.00 | 450.00 |
October | 24.72 | 15-OCT-13:00 | 31.70 | 22.20 | 5.20 | 22.98 | 151.50 | 527.00 |
November | 23.46 | 02-NOV-09:00 | 29.40 | 21.10 | 6.20 | 20.57 | 236.50 | 546.50 |
December | 23.69 | 03-DEC-10:00 | 26.10 | 22.80 | 6.70 | 24.50 | 251.50 | 3.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 22.82 | 26.10 | 20.60 | 4.10 | 19.87 | 91.00 | 3.00 | |
Maximum of Months | 25.47 | 31.70 | 24.40 | 8.20 | 25.33 | 468.50 | 546.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.10 | 01-JAN-15:00 | 27.80 | 23.03 | 4.10 | 20.92 | 91.00 | 199.00 |
February | 23.30 | 16-FEB-17:00 | 24.40 | 23.65 | 3.10 | 22.98 | 29.50 | 4.00 |
March | 22.20 | 13-MAR-10:00 | 27.20 | 23.57 | 4.60 | 21.78 | 336.00 | 148.00 |
April | 21.10 | 24-APR-23:00 | 22.80 | 21.58 | 1.50 | 18.82 | 0.00 | 0.00 |
May | 22.20 | 09-MAY-23:00 | 24.40 | 22.88 | 1.50 | 22.64 | 0.00 | 0.00 |
June | 20.80 | 09-JUN-00:10 | 22.15 | 21.03 | 3.78 | 18.14 | 0.00 | 0.00 |
July | 23.90 | 20-JUL-13:00 | 26.70 | 24.68 | 8.20 | 25.33 | 309.00 | 14.00 |
August | 23.30 | 19-AUG-14:00 | 31.70 | 25.47 | 5.20 | 25.33 | 229.00 | 409.00 |
September | 24.40 | 23-SEP-14:00 | 27.20 | 25.16 | 4.10 | 23.82 | 288.00 | 450.00 |
October | 22.80 | 24-OCT-12:00 | 26.10 | 23.69 | 4.10 | 19.70 | 259.00 | 474.50 |
November | 21.70 | 29-NOV-17:00 | 26.10 | 22.98 | 3.10 | 22.13 | 0.00 | 0.00 |
December | 22.80 | 03-DEC-10:00 | 26.10 | 23.69 | 6.70 | 24.50 | 251.50 | 3.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 20.80 | 22.15 | 21.03 | 1.50 | 18.14 | 0.00 | 0.00 | |
Maximum of Months | 24.40 | 31.70 | 25.47 | 8.20 | 25.33 | 336.00 | 474.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 26.59 | 31.34 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 26.78 | 37.09 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 27.35 | 43.34 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 28.17 | 47.38 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 29.01 | 50.82 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 29.64 | 52.70 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 29.90 | 53.08 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 29.71 | 53.00 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 29.13 | 48.47 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 28.31 | 39.62 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 27.47 | 33.78 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 26.84 | 30.10 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 28.25 | 43.42 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 26.59 | 30.10 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 29.90 | 53.08 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.271468E+09 | -159032547.9 | 0.00 | 0.00 | 744.00 | 0.00 | -112434968.1 | 59.00 | 0.00 | 0.00 |
February | 0.245091E+09 | -143586167.9 | 0.00 | 0.00 | 672.00 | 0.00 | -101504832.5 | 58.99 | 0.00 | 0.00 |
March | 0.271008E+09 | -158625541.9 | 0.00 | 0.00 | 744.00 | 0.00 | -112382675.1 | 58.99 | 0.00 | 0.00 |
April | 0.256546E+09 | -147847449.5 | 0.00 | 0.00 | 720.00 | 0.00 | -108698154.1 | 58.99 | 0.00 | 0.00 |
May | 0.260765E+09 | -148720086.9 | 0.00 | 0.00 | 744.00 | 0.00 | -112045345.9 | 58.99 | 0.00 | 0.00 |
June | 0.250463E+09 | -142212226.3 | 0.00 | 0.00 | 720.00 | 0.00 | -108250876.0 | 58.99 | 0.00 | 0.00 |
July | 0.254545E+09 | -142895833.6 | 0.00 | 0.00 | 744.00 | 0.00 | -111648755.8 | 58.99 | 0.00 | 0.00 |
August | 0.258298E+09 | -146662961.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111635246.9 | 58.99 | 0.00 | 0.00 |
September | 0.251296E+09 | -143350631.9 | 0.00 | 0.00 | 720.00 | 0.00 | -107945618.3 | 58.99 | 0.00 | 0.00 |
October | 0.262461E+09 | -150659026.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111802321.3 | 58.99 | 0.00 | 0.00 |
November | 0.257688E+09 | -149344964.6 | 0.00 | 0.00 | 720.00 | 0.00 | -108342994.7 | 58.99 | 0.00 | 0.00 |
December | 0.270197E+09 | -158052801.5 | 0.00 | 0.00 | 744.00 | 0.00 | -112144061.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.310983E+10 | -.179099E+10 | 8760.00 | -.131884E+10 | 58.99 | |||||
Minimum of Months | 0.245091E+09 | -159032547.9 | 0.00 | 0.00 | 672.00 | 0.00 | -112434968.1 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.271468E+09 | -142212226.3 | 0.00 | 0.00 | 744.00 | 0.00 | -101504832.5 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.271253E+09 | -159028047.7 | 0.00 | 0.00 | 744.00 | 0.00 | -112224599.1 | 59.00 | 0.00 | 0.00 |
February | 0.244924E+09 | -143581693.1 | 0.00 | 0.00 | 672.00 | 0.00 | -101342720.0 | 58.99 | 0.00 | 0.00 |
March | 0.270818E+09 | -158617888.8 | 0.00 | 0.00 | 744.00 | 0.00 | -112200548.7 | 58.99 | 0.00 | 0.00 |
April | 0.256366E+09 | -147825495.0 | 0.00 | 0.00 | 720.00 | 0.00 | -108540859.1 | 58.99 | 0.00 | 0.00 |
May | 0.260635E+09 | -148732035.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111902557.9 | 58.99 | 0.00 | 0.00 |
June | 0.250370E+09 | -142216479.1 | 0.00 | 0.00 | 720.00 | 0.00 | -108153937.3 | 58.99 | 0.00 | 0.00 |
July | 0.254480E+09 | -142901687.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111578298.3 | 58.99 | 0.00 | 0.00 |
August | 0.258248E+09 | -146660587.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111587723.2 | 58.99 | 0.00 | 0.00 |
September | 0.251279E+09 | -143349883.0 | 0.00 | 0.00 | 720.00 | 0.00 | -107929548.9 | 58.99 | 0.00 | 0.00 |
October | 0.262370E+09 | -150657800.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111711756.0 | 58.99 | 0.00 | 0.00 |
November | 0.257563E+09 | -149348171.8 | 0.00 | 0.00 | 720.00 | 0.00 | -108214537.5 | 58.99 | 0.00 | 0.00 |
December | 0.270029E+09 | -158051999.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111976605.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.310834E+10 | -.179097E+10 | 8760.00 | -.131736E+10 | 58.99 | |||||
Minimum of Months | 0.244924E+09 | -159028047.7 | 0.00 | 0.00 | 672.00 | 0.00 | -112224599.1 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.271253E+09 | -142216479.1 | 0.00 | 0.00 | 744.00 | 0.00 | -101342720.0 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.251052E+09 | -139837584.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111214527.7 | 59.00 | 0.00 | 0.00 |
February | 0.226704E+09 | -126371953.5 | 0.00 | 0.00 | 672.00 | 0.00 | -100332437.2 | 58.99 | 0.00 | 0.00 |
March | 0.252756E+09 | -141668399.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111087189.6 | 58.99 | 0.00 | 0.00 |
April | 0.237333E+09 | -129915698.9 | 0.00 | 0.00 | 720.00 | 0.00 | -107417560.8 | 58.99 | 0.00 | 0.00 |
May | 0.242404E+09 | -131895125.2 | 0.00 | 0.00 | 744.00 | 0.00 | -110508948.2 | 58.99 | 0.00 | 0.00 |
June | 0.233502E+09 | -126764469.5 | 0.00 | 0.00 | 720.00 | 0.00 | -106737593.6 | 58.99 | 0.00 | 0.00 |
July | 0.234670E+09 | -124852460.2 | 0.00 | 0.00 | 744.00 | 0.00 | -109817196.7 | 58.99 | 0.00 | 0.00 |
August | 0.241071E+09 | -131086354.0 | 0.00 | 0.00 | 744.00 | 0.00 | -109984490.3 | 58.99 | 0.00 | 0.00 |
September | 0.232003E+09 | -125893144.0 | 0.00 | 0.00 | 720.00 | 0.00 | -106109373.3 | 58.99 | 0.00 | 0.00 |
October | 0.242487E+09 | -132482629.0 | 0.00 | 0.00 | 744.00 | 0.00 | -110004819.7 | 58.99 | 0.00 | 0.00 |
November | 0.238798E+09 | -131882297.8 | 0.00 | 0.00 | 720.00 | 0.00 | -106916200.5 | 58.99 | 0.00 | 0.00 |
December | 0.248724E+09 | -137978454.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110745882.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.288150E+10 | -.158063E+10 | 8760.00 | -.130088E+10 | 58.99 | |||||
Minimum of Months | 0.226704E+09 | -141668399.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111214527.7 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.252756E+09 | -124852460.2 | 0.00 | 0.00 | 744.00 | 0.00 | -100332437.2 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.251080E+09 | -139837726.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111242065.3 | 59.00 | 0.00 | 0.00 |
February | 0.226722E+09 | -126370740.5 | 0.00 | 0.00 | 672.00 | 0.00 | -100351705.0 | 58.99 | 0.00 | 0.00 |
March | 0.252766E+09 | -141670102.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111096213.5 | 58.99 | 0.00 | 0.00 |
April | 0.237346E+09 | -129916862.0 | 0.00 | 0.00 | 720.00 | 0.00 | -107428979.6 | 58.99 | 0.00 | 0.00 |
May | 0.242386E+09 | -131897999.9 | 0.00 | 0.00 | 744.00 | 0.00 | -110487628.2 | 58.99 | 0.00 | 0.00 |
June | 0.233472E+09 | -126764378.8 | 0.00 | 0.00 | 720.00 | 0.00 | -106707802.4 | 58.99 | 0.00 | 0.00 |
July | 0.234607E+09 | -124854420.8 | 0.00 | 0.00 | 744.00 | 0.00 | -109753023.3 | 58.99 | 0.00 | 0.00 |
August | 0.241019E+09 | -131089843.7 | 0.00 | 0.00 | 744.00 | 0.00 | -109929354.6 | 58.99 | 0.00 | 0.00 |
September | 0.231928E+09 | -125895304.7 | 0.00 | 0.00 | 720.00 | 0.00 | -106033019.6 | 58.99 | 0.00 | 0.00 |
October | 0.242431E+09 | -132503863.4 | 0.00 | 0.00 | 744.00 | 0.00 | -109926658.9 | 58.98 | 0.00 | 0.00 |
November | 0.238786E+09 | -131900299.2 | 0.00 | 0.00 | 720.00 | 0.00 | -106885367.9 | 58.99 | 0.00 | 0.00 |
December | 0.248735E+09 | -137980973.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110754505.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.288128E+10 | -.158068E+10 | 8760.00 | -.130060E+10 | 58.99 | |||||
Minimum of Months | 0.226722E+09 | -141670102.0 | 0.00 | 0.00 | 672.00 | 0.00 | -111242065.3 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.252766E+09 | -124854420.8 | 0.00 | 0.00 | 744.00 | 0.00 | -100351705.0 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.243996E+09 | -132181708.9 | 0.00 | 0.00 | 744.00 | 0.00 | -111814669.2 | 58.99 | 0.00 | 0.00 |
February | 0.220401E+09 | -119494400.2 | 0.00 | 0.00 | 672.00 | 0.00 | -100906680.4 | 58.99 | 0.00 | 0.00 |
March | 0.245787E+09 | -134047132.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111739615.0 | 58.99 | 0.00 | 0.00 |
April | 0.230966E+09 | -122941627.4 | 0.00 | 0.00 | 720.00 | 0.00 | -108024847.4 | 58.99 | 0.00 | 0.00 |
May | 0.235802E+09 | -124741637.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111060509.7 | 58.99 | 0.00 | 0.00 |
June | 0.227223E+09 | -119924062.6 | 0.00 | 0.00 | 720.00 | 0.00 | -107298702.1 | 59.00 | 0.00 | 0.00 |
July | 0.228353E+09 | -118081220.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110271391.2 | 58.99 | 0.00 | 0.00 |
August | 0.234553E+09 | -124035779.8 | 0.00 | 0.00 | 744.00 | 0.00 | -110516961.0 | 58.99 | 0.00 | 0.00 |
September | 0.225707E+09 | -119128742.0 | 0.00 | 0.00 | 720.00 | 0.00 | -106577775.4 | 58.99 | 0.00 | 0.00 |
October | 0.235738E+09 | -125217299.6 | 0.00 | 0.00 | 744.00 | 0.00 | -110520420.1 | 58.99 | 0.00 | 0.00 |
November | 0.231962E+09 | -124550419.5 | 0.00 | 0.00 | 720.00 | 0.00 | -107411995.3 | 58.99 | 0.00 | 0.00 |
December | 0.241795E+09 | -130472806.9 | 0.00 | 0.00 | 744.00 | 0.00 | -111322551.8 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.280228E+10 | -.149482E+10 | 8760.00 | -.130747E+10 | 58.99 | |||||
Minimum of Months | 0.220401E+09 | -134047132.5 | 0.00 | 0.00 | 672.00 | 0.00 | -111814669.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.245787E+09 | -118081220.8 | 0.00 | 0.00 | 744.00 | 0.00 | -100906680.4 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.244085E+09 | -132184767.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111900200.7 | 58.99 | 0.00 | 0.00 |
February | 0.220487E+09 | -119497126.2 | 0.00 | 0.00 | 672.00 | 0.00 | -100989501.6 | 58.99 | 0.00 | 0.00 |
March | 0.245882E+09 | -134056171.4 | 0.00 | 0.00 | 744.00 | 0.00 | -111825809.4 | 58.99 | 0.00 | 0.00 |
April | 0.231054E+09 | -122928295.0 | 0.00 | 0.00 | 720.00 | 0.00 | -108125363.0 | 58.99 | 0.00 | 0.00 |
May | 0.235921E+09 | -124722063.8 | 0.00 | 0.00 | 744.00 | 0.00 | -111199092.6 | 58.99 | 0.00 | 0.00 |
June | 0.227327E+09 | -119972543.8 | 0.00 | 0.00 | 720.00 | 0.00 | -107354411.5 | 58.98 | 0.00 | 0.00 |
July | 0.228480E+09 | -118060607.4 | 0.00 | 0.00 | 744.00 | 0.00 | -110419531.9 | 58.99 | 0.00 | 0.00 |
August | 0.234683E+09 | -124054828.4 | 0.00 | 0.00 | 744.00 | 0.00 | -110628127.1 | 58.99 | 0.00 | 0.00 |
September | 0.225825E+09 | -119147282.3 | 0.00 | 0.00 | 720.00 | 0.00 | -106677855.1 | 58.98 | 0.00 | 0.00 |
October | 0.235857E+09 | -125209359.1 | 0.00 | 0.00 | 744.00 | 0.00 | -110648104.9 | 58.99 | 0.00 | 0.00 |
November | 0.232075E+09 | -124555853.4 | 0.00 | 0.00 | 720.00 | 0.00 | -107519553.0 | 58.99 | 0.00 | 0.00 |
December | 0.241903E+09 | -130483026.2 | 0.00 | 0.00 | 744.00 | 0.00 | -111419901.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.280358E+10 | -.149487E+10 | 8760.00 | -.130871E+10 | 58.99 | |||||
Minimum of Months | 0.220487E+09 | -134056171.4 | 0.00 | 0.00 | 672.00 | 0.00 | -111900200.7 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.245882E+09 | -118060607.4 | 0.00 | 0.00 | 744.00 | 0.00 | -100989501.6 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.244127E+09 | -132185905.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111940701.0 | 58.99 | 0.00 | 0.00 |
February | 0.220527E+09 | -119501495.5 | 0.00 | 0.00 | 672.00 | 0.00 | -101025888.0 | 58.99 | 0.00 | 0.00 |
March | 0.245923E+09 | -134056904.9 | 0.00 | 0.00 | 744.00 | 0.00 | -111865995.4 | 58.99 | 0.00 | 0.00 |
April | 0.231098E+09 | -122936473.8 | 0.00 | 0.00 | 720.00 | 0.00 | -108161607.9 | 58.99 | 0.00 | 0.00 |
May | 0.235954E+09 | -124725231.0 | 0.00 | 0.00 | 744.00 | 0.00 | -111228610.0 | 58.99 | 0.00 | 0.00 |
June | 0.227355E+09 | -119959189.1 | 0.00 | 0.00 | 720.00 | 0.00 | -107396160.1 | 58.98 | 0.00 | 0.00 |
July | 0.228521E+09 | -118077385.5 | 0.00 | 0.00 | 744.00 | 0.00 | -110444037.1 | 58.99 | 0.00 | 0.00 |
August | 0.234706E+09 | -124044334.7 | 0.00 | 0.00 | 744.00 | 0.00 | -110661514.6 | 58.99 | 0.00 | 0.00 |
September | 0.225863E+09 | -119133646.8 | 0.00 | 0.00 | 720.00 | 0.00 | -106729516.0 | 58.99 | 0.00 | 0.00 |
October | 0.235896E+09 | -125217268.2 | 0.00 | 0.00 | 744.00 | 0.00 | -110678785.4 | 58.99 | 0.00 | 0.00 |
November | 0.232109E+09 | -124549869.0 | 0.00 | 0.00 | 720.00 | 0.00 | -107558715.7 | 58.99 | 0.00 | 0.00 |
December | 0.241946E+09 | -130488503.7 | 0.00 | 0.00 | 744.00 | 0.00 | -111457522.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.280403E+10 | -.149488E+10 | 8760.00 | -.130915E+10 | 58.99 | |||||
Minimum of Months | 0.220527E+09 | -134056904.9 | 0.00 | 0.00 | 672.00 | 0.00 | -111940701.0 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.245923E+09 | -118077385.5 | 0.00 | 0.00 | 744.00 | 0.00 | -101025888.0 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 326.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 285.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 336.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 360.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 384.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 392.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 398.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 382.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 359.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 346.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 316.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 318.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4207.17 | ||||||||||
Minimum of Months | 285.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 398.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.219877E+11 | 0.148612E+11 | 46671.85 | 31-JAN-08:62 | 26419.71 | 0.00 |
February | 0.00 | 0.00 | 0.237113E+11 | 0.143792E+11 | 48328.51 | 17-FEB-08:62 | 22933.25 | 0.00 |
March | 0.00 | 0.00 | 0.248590E+11 | 0.164744E+11 | 47147.40 | 03-MAR-08:62 | 24417.90 | 0.00 |
April | 0.00 | 0.00 | 0.237795E+11 | 0.162439E+11 | 46189.52 | 25-APR-07:03 | 28611.61 | 0.00 |
May | 0.00 | 0.00 | 0.308337E+11 | 0.202993E+11 | 47445.44 | 10-MAY-07:02 | 25748.97 | 0.00 |
June | 0.00 | 0.00 | 0.314871E+11 | 0.206071E+11 | 46987.81 | 14-JUN-07:02 | 27269.26 | 0.00 |
July | 0.00 | 0.00 | 0.371945E+11 | 0.240054E+11 | 48293.10 | 20-JUL-07:02 | 24616.06 | 0.00 |
August | 0.00 | 0.00 | 0.378707E+11 | 0.246408E+11 | 47582.22 | 08-AUG-07:02 | 26362.94 | 0.00 |
September | 0.00 | 0.00 | 0.380464E+11 | 0.237154E+11 | 47978.37 | 30-SEP-07:02 | 24550.76 | 0.00 |
October | 0.00 | 0.00 | 0.367742E+11 | 0.234832E+11 | 47300.47 | 13-OCT-07:02 | 26860.38 | 0.00 |
November | 0.00 | 0.00 | 0.302526E+11 | 0.193376E+11 | 47389.93 | 01-NOV-07:02 | 26307.37 | 0.00 |
December | 0.00 | 0.00 | 0.271603E+11 | 0.174126E+11 | 47652.94 | 03-DEC-08:61 | 26372.95 | 0.00 |
Annual Sum or Average | 0.363957E+12 | 0.235460E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.219877E+11 | 0.143792E+11 | 46189.52 | 22933.25 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.380464E+11 | 0.246408E+11 | 48328.51 | 28611.61 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.118711E+11 | 0.831157E+10 | 24054.39 | 31-JAN-08:62 | 15660.55 | 0.00 |
February | 0.00 | 0.00 | 0.124151E+11 | 0.784157E+10 | 24753.74 | 17-FEB-08:62 | 14113.97 | 0.00 |
March | 0.00 | 0.00 | 0.129977E+11 | 0.889246E+10 | 24184.87 | 03-MAR-08:62 | 14973.44 | 0.00 |
April | 0.00 | 0.00 | 0.123499E+11 | 0.870054E+10 | 23756.38 | 18-APR-07:03 | 16456.85 | 0.00 |
May | 0.00 | 0.00 | 0.156507E+11 | 0.106129E+11 | 24386.89 | 10-MAY-07:02 | 15352.08 | 0.00 |
June | 0.00 | 0.00 | 0.157950E+11 | 0.106207E+11 | 24263.36 | 14-JUN-07:02 | 15751.37 | 0.00 |
July | 0.00 | 0.00 | 0.184370E+11 | 0.122321E+11 | 24835.21 | 20-JUL-07:02 | 14525.79 | 0.00 |
August | 0.00 | 0.00 | 0.187701E+11 | 0.125306E+11 | 24512.67 | 08-AUG-07:02 | 15334.22 | 0.00 |
September | 0.00 | 0.00 | 0.186341E+11 | 0.119355E+11 | 24656.54 | 30-SEP-07:02 | 14692.05 | 0.00 |
October | 0.00 | 0.00 | 0.184848E+11 | 0.121589E+11 | 24350.84 | 13-OCT-07:02 | 15667.81 | 0.00 |
November | 0.00 | 0.00 | 0.154477E+11 | 0.101926E+11 | 24429.52 | 01-NOV-07:02 | 15378.64 | 0.00 |
December | 0.00 | 0.00 | 0.141625E+11 | 0.941853E+10 | 24617.80 | 03-DEC-08:61 | 15166.59 | 0.00 |
Annual Sum or Average | 0.185016E+12 | 0.123448E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.118711E+11 | 0.784157E+10 | 23756.38 | 14113.97 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.187701E+11 | 0.125306E+11 | 24835.21 | 16456.85 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.927925E+10 | 0.635422E+10 | 25718.35 | 02-JAN-07:02 | 14174.20 | 0.00 |
February | 0.00 | 0.00 | 0.978726E+10 | 0.600895E+10 | 26498.45 | 18-FEB-07:02 | 12082.15 | 0.00 |
March | 0.00 | 0.00 | 0.103027E+11 | 0.689701E+10 | 26114.33 | 13-MAR-06:02 | 12965.95 | 0.00 |
April | 0.00 | 0.00 | 0.969075E+10 | 0.668029E+10 | 25637.16 | 24-APR-06:03 | 13768.22 | 0.00 |
May | 0.00 | 0.00 | 0.126607E+11 | 0.842381E+10 | 26109.48 | 15-MAY-06:02 | 12731.50 | 0.00 |
June | 0.00 | 0.00 | 0.129050E+11 | 0.847893E+10 | 25689.37 | 18-JUN-07:02 | 14979.33 | 0.00 |
July | 0.00 | 0.00 | 0.149479E+11 | 0.971175E+10 | 26486.69 | 23-JUL-07:01 | 12993.24 | 0.00 |
August | 0.00 | 0.00 | 0.155259E+11 | 0.101952E+11 | 26238.11 | 20-AUG-07:02 | 13498.76 | 0.00 |
September | 0.00 | 0.00 | 0.150564E+11 | 0.943275E+10 | 26676.59 | 25-SEP-06:02 | 11909.09 | 0.00 |
October | 0.00 | 0.00 | 0.150070E+11 | 0.969862E+10 | 26139.10 | 10-OCT-06:02 | 12789.98 | 0.00 |
November | 0.00 | 0.00 | 0.125561E+11 | 0.810388E+10 | 25935.23 | 24-NOV-07:02 | 13560.49 | 0.00 |
December | 0.00 | 0.00 | 0.112340E+11 | 0.728248E+10 | 26102.28 | 03-DEC-08:61 | 13957.59 | 0.00 |
Annual Sum or Average | 0.148953E+12 | 0.972678E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.927925E+10 | 0.600895E+10 | 25637.16 | 11909.09 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.155259E+11 | 0.101952E+11 | 26676.59 | 14979.33 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.923330E+10 | 0.632227E+10 | 25555.53 | 02-JAN-07:02 | 14093.96 | 0.00 |
February | 0.00 | 0.00 | 0.974998E+10 | 0.598426E+10 | 26330.03 | 18-FEB-07:02 | 11992.28 | 0.00 |
March | 0.00 | 0.00 | 0.102686E+11 | 0.687423E+10 | 25948.86 | 13-MAR-06:02 | 12888.89 | 0.00 |
April | 0.00 | 0.00 | 0.965473E+10 | 0.665578E+10 | 25472.54 | 24-APR-06:03 | 13672.25 | 0.00 |
May | 0.00 | 0.00 | 0.126502E+11 | 0.841939E+10 | 25945.19 | 15-MAY-06:02 | 12662.91 | 0.00 |
June | 0.00 | 0.00 | 0.129022E+11 | 0.848034E+10 | 25528.75 | 18-JUN-07:02 | 14902.61 | 0.00 |
July | 0.00 | 0.00 | 0.149702E+11 | 0.973258E+10 | 26321.76 | 23-JUL-07:01 | 12931.45 | 0.00 |
August | 0.00 | 0.00 | 0.155441E+11 | 0.102131E+11 | 26075.50 | 20-AUG-07:02 | 13438.36 | 0.00 |
September | 0.00 | 0.00 | 0.150948E+11 | 0.946427E+10 | 26512.59 | 25-SEP-06:02 | 11876.92 | 0.00 |
October | 0.00 | 0.00 | 0.150326E+11 | 0.972110E+10 | 25977.92 | 10-OCT-06:02 | 12746.85 | 0.00 |
November | 0.00 | 0.00 | 0.125437E+11 | 0.809784E+10 | 25772.93 | 24-NOV-07:02 | 13491.15 | 0.00 |
December | 0.00 | 0.00 | 0.112058E+11 | 0.726394E+10 | 25937.25 | 03-DEC-08:61 | 13876.12 | 0.00 |
Annual Sum or Average | 0.148850E+12 | 0.972290E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.923330E+10 | 0.598426E+10 | 25472.54 | 11876.92 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.155441E+11 | 0.102131E+11 | 26512.59 | 14902.61 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.897518E+10 | 0.612225E+10 | 25490.83 | 02-JAN-07:02 | 13987.42 | 0.00 |
February | 0.00 | 0.00 | 0.949746E+10 | 0.580069E+10 | 26267.19 | 18-FEB-07:02 | 11844.31 | 0.00 |
March | 0.00 | 0.00 | 0.999802E+10 | 0.666716E+10 | 25882.21 | 13-MAR-06:02 | 12771.85 | 0.00 |
April | 0.00 | 0.00 | 0.940224E+10 | 0.645951E+10 | 25406.72 | 24-APR-06:03 | 13548.73 | 0.00 |
May | 0.00 | 0.00 | 0.124082E+11 | 0.822887E+10 | 25880.12 | 15-MAY-06:02 | 12557.96 | 0.00 |
June | 0.00 | 0.00 | 0.126726E+11 | 0.829969E+10 | 25460.63 | 18-JUN-07:02 | 14775.86 | 0.00 |
July | 0.00 | 0.00 | 0.147498E+11 | 0.955681E+10 | 26253.98 | 23-JUL-07:01 | 12806.23 | 0.00 |
August | 0.00 | 0.00 | 0.153094E+11 | 0.100259E+11 | 26009.07 | 20-AUG-07:02 | 13316.11 | 0.00 |
September | 0.00 | 0.00 | 0.148730E+11 | 0.929152E+10 | 26446.99 | 25-SEP-06:02 | 11778.70 | 0.00 |
October | 0.00 | 0.00 | 0.148006E+11 | 0.953852E+10 | 25914.21 | 10-OCT-06:02 | 12654.66 | 0.00 |
November | 0.00 | 0.00 | 0.123145E+11 | 0.792075E+10 | 25707.59 | 24-NOV-07:02 | 13383.64 | 0.00 |
December | 0.00 | 0.00 | 0.109578E+11 | 0.707371E+10 | 25869.15 | 03-DEC-08:61 | 13750.41 | 0.00 |
Annual Sum or Average | 0.145959E+12 | 0.949854E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.897518E+10 | 0.580069E+10 | 25406.72 | 11778.70 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.153094E+11 | 0.100259E+11 | 26446.99 | 14775.86 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.151305E+11 | 0.100449E+11 | 44040.64 | 01-JAN-09:02 | 23952.37 | 0.00 |
February | 0.00 | 0.00 | 0.162138E+11 | 0.957938E+10 | 45031.68 | 18-FEB-08:62 | 20996.08 | 0.00 |
March | 0.00 | 0.00 | 0.171217E+11 | 0.111170E+11 | 44629.77 | 13-MAR-07:02 | 21561.85 | 0.00 |
April | 0.00 | 0.00 | 0.160001E+11 | 0.107271E+11 | 43908.11 | 24-APR-07:03 | 22987.35 | 0.00 |
May | 0.00 | 0.00 | 0.216280E+11 | 0.140194E+11 | 44688.57 | 15-MAY-07:02 | 21515.03 | 0.00 |
June | 0.00 | 0.00 | 0.221154E+11 | 0.141466E+11 | 43959.77 | 18-JUN-08:61 | 25543.30 | 0.00 |
July | 0.00 | 0.00 | 0.259600E+11 | 0.164652E+11 | 45390.28 | 23-JUL-08:61 | 22242.22 | 0.00 |
August | 0.00 | 0.00 | 0.271056E+11 | 0.174021E+11 | 44949.84 | 20-AUG-08:61 | 23249.57 | 0.00 |
September | 0.00 | 0.00 | 0.261624E+11 | 0.159914E+11 | 45640.04 | 25-SEP-07:02 | 20053.92 | 0.00 |
October | 0.00 | 0.00 | 0.262132E+11 | 0.165380E+11 | 44724.97 | 10-OCT-07:02 | 21540.06 | 0.00 |
November | 0.00 | 0.00 | 0.213974E+11 | 0.134172E+11 | 44475.21 | 24-NOV-08:62 | 23194.81 | 0.00 |
December | 0.00 | 0.00 | 0.187831E+11 | 0.117843E+11 | 44875.13 | 03-DEC-09:01 | 23019.15 | 0.00 |
Annual Sum or Average | 0.253831E+12 | 0.161233E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.151305E+11 | 0.957938E+10 | 43908.11 | 20053.92 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.271056E+11 | 0.174021E+11 | 45640.04 | 25543.30 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.777666E+10 | 0.516730E+10 | 22906.62 | 01-JAN-09:02 | 12445.82 | 0.00 |
February | 0.00 | 0.00 | 0.833402E+10 | 0.492673E+10 | 23404.28 | 18-FEB-08:62 | 10943.13 | 0.00 |
March | 0.00 | 0.00 | 0.880642E+10 | 0.572085E+10 | 23225.82 | 13-MAR-07:02 | 11188.93 | 0.00 |
April | 0.00 | 0.00 | 0.823231E+10 | 0.552289E+10 | 22840.71 | 24-APR-07:03 | 11948.04 | 0.00 |
May | 0.00 | 0.00 | 0.111594E+11 | 0.723680E+10 | 23257.82 | 15-MAY-07:02 | 11149.75 | 0.00 |
June | 0.00 | 0.00 | 0.114020E+11 | 0.729808E+10 | 22858.66 | 18-JUN-08:61 | 13258.16 | 0.00 |
July | 0.00 | 0.00 | 0.134219E+11 | 0.851762E+10 | 23606.32 | 23-JUL-08:61 | 11517.68 | 0.00 |
August | 0.00 | 0.00 | 0.140186E+11 | 0.900501E+10 | 23379.19 | 20-AUG-08:61 | 12048.77 | 0.00 |
September | 0.00 | 0.00 | 0.135176E+11 | 0.826763E+10 | 23759.82 | 25-SEP-07:02 | 10363.12 | 0.00 |
October | 0.00 | 0.00 | 0.135619E+11 | 0.856144E+10 | 23278.94 | 10-OCT-07:02 | 11173.33 | 0.00 |
November | 0.00 | 0.00 | 0.110359E+11 | 0.692637E+10 | 23136.58 | 24-NOV-08:62 | 12036.53 | 0.00 |
December | 0.00 | 0.00 | 0.967355E+10 | 0.607467E+10 | 23332.66 | 03-DEC-09:01 | 11949.84 | 0.00 |
Annual Sum or Average | 0.130940E+12 | 0.832254E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.777666E+10 | 0.492673E+10 | 22840.71 | 10363.12 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.140186E+11 | 0.900501E+10 | 23759.82 | 13258.16 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.770222E+10 | 0.511124E+10 | 22785.77 | 01-JAN-09:02 | 12359.22 | 0.00 |
February | 0.00 | 0.00 | 0.825887E+10 | 0.487357E+10 | 23284.70 | 18-FEB-08:62 | 10852.39 | 0.00 |
March | 0.00 | 0.00 | 0.872890E+10 | 0.566328E+10 | 23102.45 | 13-MAR-07:02 | 11108.53 | 0.00 |
April | 0.00 | 0.00 | 0.816538E+10 | 0.547210E+10 | 22719.99 | 24-APR-07:03 | 11863.72 | 0.00 |
May | 0.00 | 0.00 | 0.110924E+11 | 0.718558E+10 | 23134.94 | 15-MAY-07:02 | 11071.14 | 0.00 |
June | 0.00 | 0.00 | 0.113363E+11 | 0.724790E+10 | 22738.23 | 18-JUN-08:61 | 13171.11 | 0.00 |
July | 0.00 | 0.00 | 0.133583E+11 | 0.846837E+10 | 23482.33 | 23-JUL-08:61 | 11438.21 | 0.00 |
August | 0.00 | 0.00 | 0.139565E+11 | 0.895636E+10 | 23257.25 | 20-AUG-08:61 | 11971.42 | 0.00 |
September | 0.00 | 0.00 | 0.134535E+11 | 0.821879E+10 | 23634.30 | 25-SEP-07:02 | 10293.39 | 0.00 |
October | 0.00 | 0.00 | 0.134973E+11 | 0.851142E+10 | 23155.88 | 10-OCT-07:02 | 11097.27 | 0.00 |
November | 0.00 | 0.00 | 0.109641E+11 | 0.687249E+10 | 23014.29 | 24-NOV-08:62 | 11950.90 | 0.00 |
December | 0.00 | 0.00 | 0.959886E+10 | 0.601888E+10 | 23210.11 | 03-DEC-09:01 | 11867.10 | 0.00 |
Annual Sum or Average | 0.130113E+12 | 0.826000E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.770222E+10 | 0.487357E+10 | 22719.99 | 10293.39 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.139565E+11 | 0.895636E+10 | 23634.30 | 13171.11 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.761148E+10 | 0.504719E+10 | 22784.57 | 01-JAN-09:02 | 12319.24 | 0.00 |
February | 0.00 | 0.00 | 0.815339E+10 | 0.480374E+10 | 23288.23 | 18-FEB-08:62 | 10791.06 | 0.00 |
March | 0.00 | 0.00 | 0.863246E+10 | 0.559690E+10 | 23103.49 | 13-MAR-07:02 | 11073.96 | 0.00 |
April | 0.00 | 0.00 | 0.811108E+10 | 0.543413E+10 | 22719.82 | 24-APR-07:03 | 11828.34 | 0.00 |
May | 0.00 | 0.00 | 0.110868E+11 | 0.718260E+10 | 23135.98 | 15-MAY-07:02 | 11041.87 | 0.00 |
June | 0.00 | 0.00 | 0.113370E+11 | 0.724967E+10 | 22740.20 | 18-JUN-08:61 | 13150.99 | 0.00 |
July | 0.00 | 0.00 | 0.133848E+11 | 0.848955E+10 | 23486.34 | 23-JUL-08:61 | 11424.45 | 0.00 |
August | 0.00 | 0.00 | 0.140010E+11 | 0.899059E+10 | 23261.10 | 20-AUG-08:61 | 11963.32 | 0.00 |
September | 0.00 | 0.00 | 0.134710E+11 | 0.823279E+10 | 23638.83 | 25-SEP-07:02 | 10282.38 | 0.00 |
October | 0.00 | 0.00 | 0.135167E+11 | 0.852686E+10 | 23159.66 | 10-OCT-07:02 | 11083.65 | 0.00 |
November | 0.00 | 0.00 | 0.109244E+11 | 0.684566E+10 | 23015.21 | 24-NOV-08:62 | 11921.22 | 0.00 |
December | 0.00 | 0.00 | 0.952984E+10 | 0.597102E+10 | 23212.45 | 03-DEC-09:01 | 11843.61 | 0.00 |
Annual Sum or Average | 0.129760E+12 | 0.823707E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.761148E+10 | 0.480374E+10 | 22719.82 | 10282.38 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.140010E+11 | 0.899059E+10 | 23638.83 | 13150.99 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.856236E+10 | 0.582633E+10 | 25213.94 | 02-JAN-08:62 | 13775.69 | 0.00 |
February | 0.00 | 0.00 | 0.889825E+10 | 0.538823E+10 | 26146.81 | 18-FEB-08:62 | 11002.11 | 0.00 |
March | 0.00 | 0.00 | 0.956705E+10 | 0.636334E+10 | 25639.34 | 13-MAR-07:02 | 12245.95 | 0.00 |
April | 0.00 | 0.00 | 0.933583E+10 | 0.641565E+10 | 24776.17 | 09-APR-08:62 | 14949.92 | 0.00 |
May | 0.00 | 0.00 | 0.128212E+11 | 0.854671E+10 | 25626.65 | 15-MAY-07:02 | 12394.05 | 0.00 |
June | 0.00 | 0.00 | 0.130980E+11 | 0.861140E+10 | 25299.56 | 25-JUN-08:61 | 14700.98 | 0.00 |
July | 0.00 | 0.00 | 0.153942E+11 | 0.100471E+11 | 26169.06 | 23-JUL-08:61 | 12993.17 | 0.00 |
August | 0.00 | 0.00 | 0.161932E+11 | 0.107016E+11 | 25909.45 | 20-AUG-08:61 | 13442.71 | 0.00 |
September | 0.00 | 0.00 | 0.151776E+11 | 0.953962E+10 | 26206.08 | 25-SEP-07:02 | 11501.07 | 0.00 |
October | 0.00 | 0.00 | 0.153969E+11 | 0.100057E+11 | 25702.31 | 10-OCT-07:02 | 12327.05 | 0.00 |
November | 0.00 | 0.00 | 0.122113E+11 | 0.785032E+10 | 25553.00 | 06-NOV-08:62 | 13872.43 | 0.00 |
December | 0.00 | 0.00 | 0.106216E+11 | 0.683362E+10 | 25820.80 | 03-DEC-09:01 | 13203.23 | 0.00 |
Annual Sum or Average | 0.147277E+12 | 0.961296E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.856236E+10 | 0.538823E+10 | 24776.17 | 11002.11 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.161932E+11 | 0.107016E+11 | 26206.08 | 14949.92 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.143253E+10 | 0.36 | 1957.33 | 02-JAN-08:62 | 0.86 |
February | 0.131464E+10 | 0.36 | 1957.33 | 04-FEB-08:62 | 0.87 |
March | 0.143965E+10 | 0.36 | 1957.33 | 02-MAR-08:62 | 0.87 |
April | 0.138415E+10 | 0.36 | 1957.33 | 07-APR-07:03 | 0.87 |
May | 0.146434E+10 | 0.36 | 1957.33 | 03-MAY-07:03 | 0.87 |
June | 0.142952E+10 | 0.36 | 1957.33 | 01-JUN-07:02 | 0.86 |
July | 0.158697E+10 | 0.38 | 1957.33 | 01-JUL-07:02 | 0.87 |
August | 0.162003E+10 | 0.38 | 1957.33 | 01-AUG-07:02 | 0.86 |
September | 0.158687E+10 | 0.39 | 1957.33 | 01-SEP-07:02 | 0.86 |
October | 0.160737E+10 | 0.38 | 1957.33 | 01-OCT-07:02 | 0.86 |
November | 0.144747E+10 | 0.37 | 1957.33 | 01-NOV-07:02 | 0.86 |
December | 0.146040E+10 | 0.36 | 1957.33 | 01-DEC-08:62 | 0.86 |
Annual Sum or Average | 0.177739E+11 | 0.37 | |||
Minimum of Months | 0.131464E+10 | 0.36 | 1957.33 | 0.86 | |
Maximum of Months | 0.162003E+10 | 0.39 | 1957.33 | 0.87 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.689612E+09 | 0.39 | 1073.68 | 01-JAN-08:62 | 0.90 |
February | 0.640741E+09 | 0.39 | 1073.68 | 04-FEB-08:62 | 0.90 |
March | 0.701517E+09 | 0.39 | 1073.68 | 02-MAR-08:62 | 0.90 |
April | 0.669592E+09 | 0.39 | 1073.68 | 07-APR-07:03 | 0.90 |
May | 0.723717E+09 | 0.39 | 1073.68 | 01-MAY-07:03 | 0.90 |
June | 0.709264E+09 | 0.39 | 1073.68 | 01-JUN-07:02 | 0.90 |
July | 0.794884E+09 | 0.40 | 1073.68 | 01-JUL-07:02 | 0.90 |
August | 0.814512E+09 | 0.40 | 1073.68 | 01-AUG-07:02 | 0.90 |
September | 0.796854E+09 | 0.41 | 1073.68 | 01-SEP-07:02 | 0.90 |
October | 0.808949E+09 | 0.40 | 1073.68 | 01-OCT-07:02 | 0.90 |
November | 0.715443E+09 | 0.39 | 1073.68 | 01-NOV-07:02 | 0.89 |
December | 0.712153E+09 | 0.39 | 1073.68 | 01-DEC-08:62 | 0.90 |
Annual Sum or Average | 0.877724E+10 | 0.39 | |||
Minimum of Months | 0.640741E+09 | 0.39 | 1073.68 | 0.89 | |
Maximum of Months | 0.814512E+09 | 0.41 | 1073.68 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.647114E+09 | 0.30 | 1109.88 | 01-JAN-08:62 | 0.89 |
February | 0.592061E+09 | 0.30 | 1109.88 | 04-FEB-07:03 | 0.89 |
March | 0.659770E+09 | 0.30 | 1109.88 | 01-MAR-07:03 | 0.89 |
April | 0.625886E+09 | 0.30 | 1109.88 | 06-APR-06:03 | 0.90 |
May | 0.660819E+09 | 0.30 | 1109.88 | 01-MAY-06:03 | 0.90 |
June | 0.646169E+09 | 0.30 | 1109.88 | 01-JUN-06:03 | 0.90 |
July | 0.700945E+09 | 0.31 | 1109.88 | 01-JUL-06:02 | 0.89 |
August | 0.733569E+09 | 0.32 | 1109.88 | 01-AUG-06:02 | 0.89 |
September | 0.700181E+09 | 0.31 | 1109.88 | 01-SEP-06:02 | 0.89 |
October | 0.719967E+09 | 0.31 | 1109.88 | 01-OCT-07:02 | 0.89 |
November | 0.651107E+09 | 0.30 | 1109.88 | 01-NOV-06:02 | 0.89 |
December | 0.651940E+09 | 0.30 | 1109.88 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.798953E+10 | 0.30 | |||
Minimum of Months | 0.592061E+09 | 0.30 | 1109.88 | 0.89 | |
Maximum of Months | 0.733569E+09 | 0.32 | 1109.88 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.643729E+09 | 0.30 | 1103.70 | 01-JAN-08:62 | 0.89 |
February | 0.589212E+09 | 0.30 | 1103.70 | 04-FEB-07:03 | 0.89 |
March | 0.656315E+09 | 0.30 | 1103.70 | 01-MAR-07:03 | 0.89 |
April | 0.622416E+09 | 0.30 | 1103.70 | 06-APR-06:03 | 0.90 |
May | 0.658129E+09 | 0.30 | 1103.70 | 01-MAY-06:03 | 0.90 |
June | 0.643885E+09 | 0.30 | 1103.70 | 01-JUN-06:03 | 0.90 |
July | 0.700411E+09 | 0.31 | 1103.70 | 01-JUL-06:02 | 0.89 |
August | 0.732898E+09 | 0.32 | 1103.70 | 01-AUG-06:02 | 0.89 |
September | 0.700114E+09 | 0.32 | 1103.70 | 01-SEP-06:02 | 0.89 |
October | 0.719257E+09 | 0.31 | 1103.70 | 01-OCT-07:02 | 0.89 |
November | 0.648770E+09 | 0.30 | 1103.70 | 01-NOV-06:02 | 0.89 |
December | 0.648924E+09 | 0.30 | 1103.70 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.796406E+10 | 0.30 | |||
Minimum of Months | 0.589212E+09 | 0.30 | 1103.70 | 0.89 | |
Maximum of Months | 0.732898E+09 | 0.32 | 1103.70 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.639513E+09 | 0.30 | 1097.99 | 01-JAN-08:62 | 0.89 |
February | 0.584746E+09 | 0.30 | 1097.99 | 04-FEB-07:03 | 0.89 |
March | 0.652073E+09 | 0.30 | 1097.99 | 01-MAR-07:03 | 0.89 |
April | 0.618811E+09 | 0.30 | 1097.99 | 07-APR-06:03 | 0.90 |
May | 0.652615E+09 | 0.30 | 1097.99 | 03-MAY-06:03 | 0.90 |
June | 0.638036E+09 | 0.30 | 1097.99 | 01-JUN-06:03 | 0.90 |
July | 0.691747E+09 | 0.31 | 1097.99 | 01-JUL-06:02 | 0.89 |
August | 0.723887E+09 | 0.32 | 1097.99 | 01-AUG-06:02 | 0.89 |
September | 0.691578E+09 | 0.31 | 1097.99 | 01-SEP-06:02 | 0.89 |
October | 0.710930E+09 | 0.31 | 1097.99 | 01-OCT-07:02 | 0.89 |
November | 0.643151E+09 | 0.30 | 1097.99 | 01-NOV-06:02 | 0.89 |
December | 0.643929E+09 | 0.30 | 1097.99 | 01-DEC-07:02 | 0.89 |
Annual Sum or Average | 0.789102E+10 | 0.30 | |||
Minimum of Months | 0.584746E+09 | 0.30 | 1097.99 | 0.89 | |
Maximum of Months | 0.723887E+09 | 0.32 | 1097.99 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.959436E+09 | 0.26 | 1776.34 | 01-JAN-09:02 | 0.86 |
February | 0.880695E+09 | 0.27 | 1776.34 | 06-FEB-08:62 | 0.86 |
March | 0.979096E+09 | 0.27 | 1776.34 | 02-MAR-08:62 | 0.87 |
April | 0.924826E+09 | 0.26 | 1776.34 | 07-APR-07:03 | 0.87 |
May | 0.989866E+09 | 0.27 | 1776.34 | 01-MAY-07:03 | 0.87 |
June | 0.971951E+09 | 0.27 | 1776.34 | 01-JUN-07:02 | 0.87 |
July | 0.107708E+10 | 0.28 | 1776.34 | 01-JUL-07:02 | 0.87 |
August | 0.113012E+10 | 0.29 | 1776.34 | 01-AUG-07:02 | 0.86 |
September | 0.107990E+10 | 0.29 | 1776.34 | 01-SEP-07:02 | 0.86 |
October | 0.110782E+10 | 0.29 | 1776.34 | 01-OCT-08:62 | 0.86 |
November | 0.981221E+09 | 0.27 | 1776.34 | 01-NOV-07:02 | 0.86 |
December | 0.971636E+09 | 0.26 | 1776.34 | 01-DEC-08:62 | 0.86 |
Annual Sum or Average | 0.120537E+11 | 0.27 | |||
Minimum of Months | 0.880695E+09 | 0.26 | 1776.34 | 0.86 | |
Maximum of Months | 0.113012E+10 | 0.29 | 1776.34 | 0.87 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.516842E+09 | 0.27 | 957.28 | 01-JAN-09:02 | 0.89 |
February | 0.474329E+09 | 0.28 | 957.28 | 06-FEB-08:62 | 0.89 |
March | 0.527469E+09 | 0.28 | 957.28 | 02-MAR-08:62 | 0.90 |
April | 0.498182E+09 | 0.27 | 957.28 | 09-APR-08:62 | 0.90 |
May | 0.533540E+09 | 0.28 | 957.28 | 04-MAY-07:03 | 0.90 |
June | 0.523639E+09 | 0.28 | 957.28 | 01-JUN-07:02 | 0.90 |
July | 0.581183E+09 | 0.29 | 957.28 | 01-JUL-07:02 | 0.90 |
August | 0.610346E+09 | 0.30 | 957.28 | 01-AUG-07:02 | 0.89 |
September | 0.582228E+09 | 0.30 | 957.28 | 01-SEP-07:02 | 0.89 |
October | 0.598118E+09 | 0.30 | 957.28 | 01-OCT-08:62 | 0.89 |
November | 0.528671E+09 | 0.28 | 957.28 | 01-NOV-07:02 | 0.89 |
December | 0.523416E+09 | 0.27 | 957.28 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.649796E+10 | 0.28 | |||
Minimum of Months | 0.474329E+09 | 0.27 | 957.28 | 0.89 | |
Maximum of Months | 0.610346E+09 | 0.30 | 957.28 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.513093E+09 | 0.27 | 950.44 | 01-JAN-09:02 | 0.89 |
February | 0.470861E+09 | 0.28 | 950.44 | 06-FEB-08:62 | 0.89 |
March | 0.523649E+09 | 0.28 | 950.44 | 02-MAR-08:62 | 0.90 |
April | 0.494565E+09 | 0.27 | 950.44 | 09-APR-08:62 | 0.90 |
May | 0.529820E+09 | 0.28 | 950.44 | 04-MAY-07:03 | 0.90 |
June | 0.520016E+09 | 0.28 | 950.44 | 01-JUN-07:02 | 0.90 |
July | 0.577480E+09 | 0.29 | 950.44 | 01-JUL-07:02 | 0.90 |
August | 0.606608E+09 | 0.30 | 950.44 | 01-AUG-07:02 | 0.89 |
September | 0.578537E+09 | 0.30 | 950.44 | 01-SEP-07:02 | 0.89 |
October | 0.594348E+09 | 0.30 | 950.44 | 01-OCT-08:62 | 0.89 |
November | 0.524976E+09 | 0.28 | 950.44 | 01-NOV-07:02 | 0.89 |
December | 0.519667E+09 | 0.27 | 950.44 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.645362E+10 | 0.28 | |||
Minimum of Months | 0.470861E+09 | 0.27 | 950.44 | 0.89 | |
Maximum of Months | 0.606608E+09 | 0.30 | 950.44 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.512980E+09 | 0.27 | 950.86 | 01-JAN-09:02 | 0.89 |
February | 0.470433E+09 | 0.27 | 950.86 | 17-FEB-08:62 | 0.89 |
March | 0.523567E+09 | 0.28 | 950.86 | 02-MAR-08:62 | 0.90 |
April | 0.494554E+09 | 0.27 | 950.86 | 09-APR-08:62 | 0.90 |
May | 0.530284E+09 | 0.28 | 950.86 | 05-MAY-07:03 | 0.89 |
June | 0.520691E+09 | 0.28 | 950.86 | 01-JUN-07:02 | 0.90 |
July | 0.578944E+09 | 0.29 | 950.86 | 01-JUL-07:02 | 0.90 |
August | 0.608591E+09 | 0.30 | 950.86 | 01-AUG-07:02 | 0.89 |
September | 0.579785E+09 | 0.30 | 950.86 | 01-SEP-07:02 | 0.89 |
October | 0.595688E+09 | 0.30 | 950.86 | 01-OCT-08:62 | 0.89 |
November | 0.525085E+09 | 0.28 | 950.86 | 01-NOV-07:02 | 0.89 |
December | 0.519610E+09 | 0.27 | 950.86 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.646021E+10 | 0.28 | |||
Minimum of Months | 0.470433E+09 | 0.27 | 950.86 | 0.89 | |
Maximum of Months | 0.608591E+09 | 0.30 | 950.86 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.592929E+09 | 0.27 | 1099.32 | 01-JAN-09:02 | 0.89 |
February | 0.542360E+09 | 0.27 | 1099.32 | 17-FEB-08:62 | 0.89 |
March | 0.604856E+09 | 0.28 | 1099.32 | 02-MAR-08:62 | 0.89 |
April | 0.572265E+09 | 0.27 | 1099.32 | 09-APR-08:62 | 0.89 |
May | 0.620517E+09 | 0.28 | 1099.32 | 06-MAY-07:02 | 0.89 |
June | 0.610716E+09 | 0.29 | 1099.32 | 01-JUN-07:02 | 0.89 |
July | 0.683270E+09 | 0.30 | 1099.32 | 01-JUL-07:02 | 0.89 |
August | 0.722134E+09 | 0.31 | 1099.32 | 01-AUG-07:02 | 0.89 |
September | 0.678732E+09 | 0.30 | 1099.32 | 01-SEP-07:02 | 0.89 |
October | 0.701986E+09 | 0.30 | 1099.32 | 01-OCT-08:62 | 0.89 |
November | 0.607858E+09 | 0.28 | 1099.32 | 01-NOV-07:02 | 0.89 |
December | 0.600171E+09 | 0.27 | 1099.32 | 01-DEC-08:62 | 0.89 |
Annual Sum or Average | 0.753779E+10 | 0.29 | |||
Minimum of Months | 0.542360E+09 | 0.27 | 1099.32 | 0.89 | |
Maximum of Months | 0.722134E+09 | 0.31 | 1099.32 | 0.89 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 1.44 | 0.00 |
October | 0.06 | 0.00 |
November | 0.06 | 0.00 |
December | 0.14 | 0.00 |
Annual Sum or Average | 1.69 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.44 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 1.53 | 0.00 |
October | 0.14 | 0.00 |
November | 0.14 | 0.00 |
December | 0.14 | 0.00 |
Annual Sum or Average | 1.94 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.53 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.14 | 0.75 |
February | 0.64 | 0.75 |
March | 0.93 | 0.75 |
April | 0.88 | 0.75 |
May | 1.79 | 0.75 |
June | 2.16 | 0.75 |
July | 3.60 | 0.75 |
August | 3.54 | 0.75 |
September | 2.63 | 0.75 |
October | 2.64 | 0.75 |
November | 0.99 | 0.75 |
December | 0.82 | 0.75 |
Annual Sum or Average | 20.77 | 0.75 |
Minimum of Months | 0.14 | 0.75 |
Maximum of Months | 3.60 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.14 | 0.75 |
February | 0.64 | 0.75 |
March | 0.85 | 0.75 |
April | 0.88 | 0.75 |
May | 1.79 | 0.75 |
June | 2.16 | 0.75 |
July | 3.60 | 0.75 |
August | 3.54 | 0.75 |
September | 2.63 | 0.75 |
October | 2.64 | 0.75 |
November | 0.99 | 0.75 |
December | 0.65 | 0.75 |
Annual Sum or Average | 20.52 | 0.75 |
Minimum of Months | 0.14 | 0.75 |
Maximum of Months | 3.60 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.14 | 0.75 |
February | 0.56 | 0.75 |
March | 0.68 | 0.75 |
April | 0.80 | 0.75 |
May | 1.57 | 0.75 |
June | 2.00 | 0.75 |
July | 3.60 | 0.75 |
August | 3.54 | 0.75 |
September | 2.58 | 0.75 |
October | 2.56 | 0.75 |
November | 0.99 | 0.75 |
December | 0.65 | 0.75 |
Annual Sum or Average | 19.66 | 0.75 |
Minimum of Months | 0.14 | 0.75 |
Maximum of Months | 3.60 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.26 | 3.30 |
April | 0.30 | 3.30 |
May | 0.70 | 3.30 |
June | 0.57 | 3.30 |
July | 1.41 | 3.17 |
August | 1.00 | 3.30 |
September | 0.82 | 3.07 |
October | 0.60 | 2.99 |
November | 0.25 | 3.30 |
December | 0.21 | 3.30 |
Annual Sum or Average | 6.10 | 3.21 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.41 | 3.30 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.18 | 1.65 |
April | 0.30 | 1.65 |
May | 0.70 | 1.65 |
June | 0.51 | 1.65 |
July | 1.16 | 1.57 |
August | 0.74 | 1.65 |
September | 0.76 | 1.53 |
October | 0.57 | 1.49 |
November | 0.11 | 1.65 |
December | 0.21 | 1.65 |
Annual Sum or Average | 5.23 | 1.60 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.16 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.18 | 1.65 |
April | 0.30 | 1.65 |
May | 0.70 | 1.65 |
June | 0.51 | 1.65 |
July | 1.10 | 1.65 |
August | 0.74 | 1.65 |
September | 0.70 | 1.65 |
October | 0.51 | 1.47 |
November | 0.11 | 1.65 |
December | 0.21 | 1.65 |
Annual Sum or Average | 5.06 | 1.63 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.10 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.12 | 1.65 |
April | 0.30 | 1.65 |
May | 0.64 | 1.65 |
June | 0.51 | 1.65 |
July | 1.10 | 1.65 |
August | 0.74 | 1.65 |
September | 0.65 | 1.65 |
October | 0.51 | 1.47 |
November | 0.11 | 1.65 |
December | 0.21 | 1.65 |
Annual Sum or Average | 4.90 | 1.63 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.10 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.26 | 1.65 |
April | 0.30 | 1.65 |
May | 0.75 | 1.65 |
June | 0.62 | 1.65 |
July | 1.63 | 1.37 |
August | 1.56 | 1.06 |
September | 1.45 | 0.86 |
October | 0.74 | 1.34 |
November | 0.17 | 1.65 |
December | 0.21 | 1.65 |
Annual Sum or Average | 7.69 | 1.29 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.63 | 1.65 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.687673E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.701077E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.753581E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.727639E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.898916E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.907205E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.106213E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.108814E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.107234E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.105435E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.876330E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.804972E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.106344E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.687673E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.108814E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.360654E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.361132E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.387616E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.371843E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.453293E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.453670E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.527349E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.540170E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.527490E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.529121E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.443697E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.413134E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.536917E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.360654E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.540170E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.290461E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.290669E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.315469E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.299840E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.371071E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.373435E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.428544E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.448943E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.427120E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.431847E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.364084E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.332878E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.437436E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.290461E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.448943E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.288892E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.289361E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.314123E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.298445E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.370263E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.372846E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.428743E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.449035E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.427709E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.432098E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.363306E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.331704E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.436652E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.288892E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.449035E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.282867E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.283517E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.307869E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.292650E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.364550E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.367390E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.422928E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.442802E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.421922E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.426045E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.357884E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.325946E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.429637E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.282867E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.442802E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.470709E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.477368E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.519276E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.490591E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.626802E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.633046E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.737537E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.776935E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.735976E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.747085E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.614457E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.551385E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.738117E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.470709E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.776935E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.241244E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.244352E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.265994E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.251358E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.321337E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.324265E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.378671E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.399070E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.377566E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.383806E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.314950E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.282564E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.378518E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.241244E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.399070E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.239105E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.242254E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.263768E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.249385E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.319336E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.322324E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.376727E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.397132E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.375620E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.381822E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.312876E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.280434E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.376078E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.239105E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.397132E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.237064E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.239924E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.261613E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.248160E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.319266E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.322420E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.377514E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.398392E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.376175E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.382436E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.312074E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.278936E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.375397E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.237064E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.398392E+10 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.268058E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.265456E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.292599E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.285137E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.369311E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.372805E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.435996E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.462600E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.427270E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.438588E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.351357E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.313349E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.428252E+11 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.265456E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.462600E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.143253E+10 | 0.219877E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.131464E+10 | 0.237113E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143965E+10 | 0.248590E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.138415E+10 | 0.237795E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.146434E+10 | 0.308337E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.142952E+10 | 0.314871E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.158697E+10 | 0.371945E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.162003E+10 | 0.378707E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.158687E+10 | 0.380464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.160737E+10 | 0.367742E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144747E+10 | 0.302526E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.146040E+10 | 0.271603E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.177739E+11 | 0.363957E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.131464E+10 | 0.219877E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.162003E+10 | 0.380464E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.689612E+09 | 0.118711E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.640741E+09 | 0.124151E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.701517E+09 | 0.129977E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.669592E+09 | 0.123499E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.723717E+09 | 0.156507E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.709264E+09 | 0.157950E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.794884E+09 | 0.184370E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.814512E+09 | 0.187701E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.796854E+09 | 0.186341E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.808949E+09 | 0.184848E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.715443E+09 | 0.154477E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.712153E+09 | 0.141625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.877724E+10 | 0.185016E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.640741E+09 | 0.118711E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.814512E+09 | 0.187701E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.647114E+09 | 0.927925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.592061E+09 | 0.978726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.659770E+09 | 0.103027E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.625886E+09 | 0.969075E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.660819E+09 | 0.126607E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.646169E+09 | 0.129050E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.700945E+09 | 0.149479E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.733569E+09 | 0.155259E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.700181E+09 | 0.150564E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.719967E+09 | 0.150070E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.651107E+09 | 0.125561E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651940E+09 | 0.112340E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.798953E+10 | 0.148953E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.592061E+09 | 0.927925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.733569E+09 | 0.155259E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.643729E+09 | 0.923330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.589212E+09 | 0.974998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.656315E+09 | 0.102686E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.622416E+09 | 0.965473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.658129E+09 | 0.126502E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.643885E+09 | 0.129022E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.700411E+09 | 0.149702E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.732898E+09 | 0.155441E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.700114E+09 | 0.150948E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.719257E+09 | 0.150326E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.648770E+09 | 0.125437E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.648924E+09 | 0.112058E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.796406E+10 | 0.148850E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.589212E+09 | 0.923330E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.732898E+09 | 0.155441E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.639513E+09 | 0.897518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.584746E+09 | 0.949746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.652073E+09 | 0.999802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.618811E+09 | 0.940224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.652615E+09 | 0.124082E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.638036E+09 | 0.126726E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.691747E+09 | 0.147498E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.723887E+09 | 0.153094E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.691578E+09 | 0.148730E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.710930E+09 | 0.148006E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.643151E+09 | 0.123145E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.643929E+09 | 0.109578E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.789102E+10 | 0.145959E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.584746E+09 | 0.897518E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.723887E+09 | 0.153094E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.959436E+09 | 0.151305E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.880695E+09 | 0.162138E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.979096E+09 | 0.171217E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.924826E+09 | 0.160001E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.989866E+09 | 0.216280E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.971951E+09 | 0.221154E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.107708E+10 | 0.259600E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.113012E+10 | 0.271056E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.107990E+10 | 0.261624E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.110782E+10 | 0.262132E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.981221E+09 | 0.213974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.971636E+09 | 0.187831E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.120537E+11 | 0.253831E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.880695E+09 | 0.151305E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.113012E+10 | 0.271056E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.516842E+09 | 0.777666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.474329E+09 | 0.833402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.527469E+09 | 0.880642E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.498182E+09 | 0.823231E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.533540E+09 | 0.111594E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.523639E+09 | 0.114020E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.581183E+09 | 0.134219E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.610346E+09 | 0.140186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.582228E+09 | 0.135176E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.598118E+09 | 0.135619E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.528671E+09 | 0.110359E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.523416E+09 | 0.967355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.649796E+10 | 0.130940E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.474329E+09 | 0.777666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.610346E+09 | 0.140186E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.513093E+09 | 0.770222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.470861E+09 | 0.825887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.523649E+09 | 0.872890E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.494565E+09 | 0.816538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.529820E+09 | 0.110924E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.520016E+09 | 0.113363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.577480E+09 | 0.133583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.606608E+09 | 0.139565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.578537E+09 | 0.134535E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.594348E+09 | 0.134973E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.524976E+09 | 0.109641E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.519667E+09 | 0.959886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.645362E+10 | 0.130113E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.470861E+09 | 0.770222E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.606608E+09 | 0.139565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.512980E+09 | 0.761148E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.470433E+09 | 0.815339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.523567E+09 | 0.863246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.494554E+09 | 0.811108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.530284E+09 | 0.110868E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.520691E+09 | 0.113370E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.578944E+09 | 0.133848E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.608591E+09 | 0.140010E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.579785E+09 | 0.134710E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.595688E+09 | 0.135167E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.525085E+09 | 0.109244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.519610E+09 | 0.952984E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.646021E+10 | 0.129760E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.470433E+09 | 0.761148E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.608591E+09 | 0.140010E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.592929E+09 | 0.856236E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.542360E+09 | 0.889825E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.604856E+09 | 0.956705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.572265E+09 | 0.933583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.620517E+09 | 0.128212E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.610716E+09 | 0.130980E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.683270E+09 | 0.153942E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.722134E+09 | 0.161932E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.678732E+09 | 0.151776E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.701986E+09 | 0.153969E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.607858E+09 | 0.122113E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.600171E+09 | 0.106216E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.753779E+10 | 0.147277E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.542360E+09 | 0.856236E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.722134E+09 | 0.161932E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.143253E+10 | 0.00 | 0.00 | 0.00 | 0.544420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.131464E+10 | 0.00 | 0.00 | 0.00 | 0.569613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143965E+10 | 0.00 | 0.00 | 0.00 | 0.609615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.138415E+10 | 0.00 | 0.00 | 0.00 | 0.589224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.146434E+10 | 0.00 | 0.00 | 0.00 | 0.752482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.142952E+10 | 0.00 | 0.00 | 0.00 | 0.764252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.158697E+10 | 0.00 | 0.00 | 0.00 | 0.903438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.162003E+10 | 0.00 | 0.00 | 0.00 | 0.926135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.158687E+10 | 0.00 | 0.00 | 0.00 | 0.913648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.160737E+10 | 0.00 | 0.00 | 0.00 | 0.893615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144747E+10 | 0.00 | 0.00 | 0.00 | 0.731583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.146040E+10 | 0.00 | 0.00 | 0.00 | 0.658931E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.177739E+11 | 0.00 | 0.00 | 0.00 | 0.885696E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.131464E+10 | 0.00 | 0.00 | 0.00 | 0.544420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.162003E+10 | 0.00 | 0.00 | 0.00 | 0.926135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.689612E+09 | 0.00 | 0.00 | 0.00 | 0.291692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.640741E+09 | 0.00 | 0.00 | 0.00 | 0.297057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.701517E+09 | 0.00 | 0.00 | 0.00 | 0.317465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.669592E+09 | 0.00 | 0.00 | 0.00 | 0.304884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.723717E+09 | 0.00 | 0.00 | 0.00 | 0.380922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.709264E+09 | 0.00 | 0.00 | 0.00 | 0.382744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.794884E+09 | 0.00 | 0.00 | 0.00 | 0.447861E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.814512E+09 | 0.00 | 0.00 | 0.00 | 0.458719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.796854E+09 | 0.00 | 0.00 | 0.00 | 0.447805E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.808949E+09 | 0.00 | 0.00 | 0.00 | 0.448226E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.715443E+09 | 0.00 | 0.00 | 0.00 | 0.372153E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.712153E+09 | 0.00 | 0.00 | 0.00 | 0.341919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.877724E+10 | 0.00 | 0.00 | 0.00 | 0.449145E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.640741E+09 | 0.00 | 0.00 | 0.00 | 0.291692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.814512E+09 | 0.00 | 0.00 | 0.00 | 0.458719E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.647114E+09 | 0.00 | 0.00 | 0.00 | 0.225750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.592061E+09 | 0.00 | 0.00 | 0.00 | 0.231463E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.659770E+09 | 0.00 | 0.00 | 0.00 | 0.249492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.625886E+09 | 0.00 | 0.00 | 0.00 | 0.237252E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.660819E+09 | 0.00 | 0.00 | 0.00 | 0.304989E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.646169E+09 | 0.00 | 0.00 | 0.00 | 0.308818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.700945E+09 | 0.00 | 0.00 | 0.00 | 0.358450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.733569E+09 | 0.00 | 0.00 | 0.00 | 0.375586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.700181E+09 | 0.00 | 0.00 | 0.00 | 0.357102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.719967E+09 | 0.00 | 0.00 | 0.00 | 0.359850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.651107E+09 | 0.00 | 0.00 | 0.00 | 0.298973E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.651940E+09 | 0.00 | 0.00 | 0.00 | 0.267684E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.798953E+10 | 0.00 | 0.00 | 0.00 | 0.357541E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.592061E+09 | 0.00 | 0.00 | 0.00 | 0.225750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.733569E+09 | 0.00 | 0.00 | 0.00 | 0.375586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.643729E+09 | 0.00 | 0.00 | 0.00 | 0.224519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.589212E+09 | 0.00 | 0.00 | 0.00 | 0.230440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.656315E+09 | 0.00 | 0.00 | 0.00 | 0.248492E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.622416E+09 | 0.00 | 0.00 | 0.00 | 0.236204E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.658129E+09 | 0.00 | 0.00 | 0.00 | 0.304450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.643885E+09 | 0.00 | 0.00 | 0.00 | 0.308457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.700411E+09 | 0.00 | 0.00 | 0.00 | 0.358702E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.732898E+09 | 0.00 | 0.00 | 0.00 | 0.375745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.700114E+09 | 0.00 | 0.00 | 0.00 | 0.357698E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.719257E+09 | 0.00 | 0.00 | 0.00 | 0.360172E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.648770E+09 | 0.00 | 0.00 | 0.00 | 0.298429E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.648924E+09 | 0.00 | 0.00 | 0.00 | 0.266811E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.796406E+10 | 0.00 | 0.00 | 0.00 | 0.357012E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.589212E+09 | 0.00 | 0.00 | 0.00 | 0.224519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.732898E+09 | 0.00 | 0.00 | 0.00 | 0.375745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.639513E+09 | 0.00 | 0.00 | 0.00 | 0.218915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.584746E+09 | 0.00 | 0.00 | 0.00 | 0.225042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.652073E+09 | 0.00 | 0.00 | 0.00 | 0.242662E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.618811E+09 | 0.00 | 0.00 | 0.00 | 0.230768E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.652615E+09 | 0.00 | 0.00 | 0.00 | 0.299288E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.638036E+09 | 0.00 | 0.00 | 0.00 | 0.303586E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.691747E+09 | 0.00 | 0.00 | 0.00 | 0.353754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.723887E+09 | 0.00 | 0.00 | 0.00 | 0.370413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.691578E+09 | 0.00 | 0.00 | 0.00 | 0.352764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.710930E+09 | 0.00 | 0.00 | 0.00 | 0.354952E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.643151E+09 | 0.00 | 0.00 | 0.00 | 0.293569E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.643929E+09 | 0.00 | 0.00 | 0.00 | 0.261553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.789102E+10 | 0.00 | 0.00 | 0.00 | 0.350727E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.584746E+09 | 0.00 | 0.00 | 0.00 | 0.218915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.723887E+09 | 0.00 | 0.00 | 0.00 | 0.370413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.959436E+09 | 0.00 | 0.00 | 0.00 | 0.374765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.880695E+09 | 0.00 | 0.00 | 0.00 | 0.389298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.979096E+09 | 0.00 | 0.00 | 0.00 | 0.421366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.924826E+09 | 0.00 | 0.00 | 0.00 | 0.398109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.989866E+09 | 0.00 | 0.00 | 0.00 | 0.527816E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.971951E+09 | 0.00 | 0.00 | 0.00 | 0.535851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.107708E+10 | 0.00 | 0.00 | 0.00 | 0.629829E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.113012E+10 | 0.00 | 0.00 | 0.00 | 0.663922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.107990E+10 | 0.00 | 0.00 | 0.00 | 0.627986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.110782E+10 | 0.00 | 0.00 | 0.00 | 0.636303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.981221E+09 | 0.00 | 0.00 | 0.00 | 0.516335E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.971636E+09 | 0.00 | 0.00 | 0.00 | 0.454221E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.120537E+11 | 0.00 | 0.00 | 0.00 | 0.617580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.880695E+09 | 0.00 | 0.00 | 0.00 | 0.374765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.113012E+10 | 0.00 | 0.00 | 0.00 | 0.663922E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.516842E+09 | 0.00 | 0.00 | 0.00 | 0.189560E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.474329E+09 | 0.00 | 0.00 | 0.00 | 0.196919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.527469E+09 | 0.00 | 0.00 | 0.00 | 0.213248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.498182E+09 | 0.00 | 0.00 | 0.00 | 0.201540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.533540E+09 | 0.00 | 0.00 | 0.00 | 0.267983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.523639E+09 | 0.00 | 0.00 | 0.00 | 0.271901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.581183E+09 | 0.00 | 0.00 | 0.00 | 0.320553E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.610346E+09 | 0.00 | 0.00 | 0.00 | 0.338036E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.582228E+09 | 0.00 | 0.00 | 0.00 | 0.319343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.598118E+09 | 0.00 | 0.00 | 0.00 | 0.323994E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.528671E+09 | 0.00 | 0.00 | 0.00 | 0.262083E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.523416E+09 | 0.00 | 0.00 | 0.00 | 0.230223E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.649796E+10 | 0.00 | 0.00 | 0.00 | 0.313538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.474329E+09 | 0.00 | 0.00 | 0.00 | 0.189560E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.610346E+09 | 0.00 | 0.00 | 0.00 | 0.338036E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.513093E+09 | 0.00 | 0.00 | 0.00 | 0.187796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.470861E+09 | 0.00 | 0.00 | 0.00 | 0.195168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.523649E+09 | 0.00 | 0.00 | 0.00 | 0.211403E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.494565E+09 | 0.00 | 0.00 | 0.00 | 0.199928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.529820E+09 | 0.00 | 0.00 | 0.00 | 0.266354E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.520016E+09 | 0.00 | 0.00 | 0.00 | 0.270322E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.577480E+09 | 0.00 | 0.00 | 0.00 | 0.318979E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.606608E+09 | 0.00 | 0.00 | 0.00 | 0.336471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.578537E+09 | 0.00 | 0.00 | 0.00 | 0.317766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.594348E+09 | 0.00 | 0.00 | 0.00 | 0.322387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.524976E+09 | 0.00 | 0.00 | 0.00 | 0.260378E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.519667E+09 | 0.00 | 0.00 | 0.00 | 0.228467E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.645362E+10 | 0.00 | 0.00 | 0.00 | 0.311542E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.470861E+09 | 0.00 | 0.00 | 0.00 | 0.187796E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.606608E+09 | 0.00 | 0.00 | 0.00 | 0.336471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.512980E+09 | 0.00 | 0.00 | 0.00 | 0.185766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.470433E+09 | 0.00 | 0.00 | 0.00 | 0.192880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.523567E+09 | 0.00 | 0.00 | 0.00 | 0.209256E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.494554E+09 | 0.00 | 0.00 | 0.00 | 0.198704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.530284E+09 | 0.00 | 0.00 | 0.00 | 0.266237E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.520691E+09 | 0.00 | 0.00 | 0.00 | 0.270351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.578944E+09 | 0.00 | 0.00 | 0.00 | 0.319619E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.608591E+09 | 0.00 | 0.00 | 0.00 | 0.337533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.579785E+09 | 0.00 | 0.00 | 0.00 | 0.318197E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.595688E+09 | 0.00 | 0.00 | 0.00 | 0.322867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.525085E+09 | 0.00 | 0.00 | 0.00 | 0.259566E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.519610E+09 | 0.00 | 0.00 | 0.00 | 0.226975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.646021E+10 | 0.00 | 0.00 | 0.00 | 0.310795E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.470433E+09 | 0.00 | 0.00 | 0.00 | 0.185766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.608591E+09 | 0.00 | 0.00 | 0.00 | 0.337533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.592929E+09 | 0.00 | 0.00 | 0.00 | 0.208765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.542360E+09 | 0.00 | 0.00 | 0.00 | 0.211220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.604856E+09 | 0.00 | 0.00 | 0.00 | 0.232113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.572265E+09 | 0.00 | 0.00 | 0.00 | 0.227911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.620517E+09 | 0.00 | 0.00 | 0.00 | 0.307259E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.610716E+09 | 0.00 | 0.00 | 0.00 | 0.311733E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.683270E+09 | 0.00 | 0.00 | 0.00 | 0.367669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.722134E+09 | 0.00 | 0.00 | 0.00 | 0.390387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.678732E+09 | 0.00 | 0.00 | 0.00 | 0.359397E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.701986E+09 | 0.00 | 0.00 | 0.00 | 0.368389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.607858E+09 | 0.00 | 0.00 | 0.00 | 0.290571E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.600171E+09 | 0.00 | 0.00 | 0.00 | 0.253332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.753779E+10 | 0.00 | 0.00 | 0.00 | 0.352875E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.542360E+09 | 0.00 | 0.00 | 0.00 | 0.208765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.722134E+09 | 0.00 | 0.00 | 0.00 | 0.390387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 15980700.35 | 0.444575E+10 | 0.00 | 2647532.11 | 38892586.76 | 0.00 | 0.187020E+09 | 0.00 | 0.57 |
February | 18659270.35 | 0.654673E+10 | 0.00 | 1433020.29 | 73705940.10 | 0.00 | 0.139924E+09 | 0.00 | 0.57 |
March | 29315978.09 | 0.614637E+10 | 0.00 | 1115372.53 | 37583428.70 | 0.00 | 86281669.52 | 0.00 | 0.57 |
April | 6545841.40 | 0.583671E+10 | 0.00 | 488471.28 | 55364339.03 | 0.00 | 18787338.26 | 0.00 | 0.57 |
May | 0.00 | 0.947571E+10 | 0.00 | 18762.44 | 89272756.81 | 0.00 | 0.00 | 0.00 | 0.57 |
June | 0.00 | 0.982240E+10 | 0.00 | 0.00 | 89116817.90 | 0.00 | 0.00 | 0.00 | 0.57 |
July | 283753.52 | 0.126112E+11 | 0.00 | 161686.78 | 80173053.31 | 0.00 | 349687.95 | 0.00 | 0.57 |
August | 0.00 | 0.130843E+11 | 0.00 | 0.00 | 99596107.17 | 0.00 | 0.00 | 0.00 | 0.57 |
September | 0.00 | 0.133614E+11 | 0.00 | 0.00 | 79051689.19 | 0.00 | 0.00 | 0.00 | 0.57 |
October | 0.00 | 0.126160E+11 | 0.00 | 81184.19 | 98037309.30 | 0.00 | 0.00 | 0.00 | 0.57 |
November | 98718.37 | 0.898084E+10 | 0.00 | 141458.14 | 72578189.21 | 0.00 | 2694066.57 | 0.00 | 0.57 |
December | 2000100.81 | 0.720278E+10 | 0.00 | 624270.75 | 52347385.23 | 0.00 | 19030922.49 | 0.00 | 0.57 |
Annual Sum or Average | 72884362.89 | 0.110130E+12 | 0.00 | 6711758.52 | 0.865720E+09 | 0.00 | 0.454088E+09 | 0.00 | 0.57 |
Minimum of Months | 0.00 | 0.444575E+10 | 0.00 | 0.00 | 37583428.70 | 0.00 | 0.00 | 0.00 | 0.57 |
Maximum of Months | 29315978.09 | 0.133614E+11 | 0.00 | 2647532.11 | 99596107.17 | 0.00 | 0.187020E+09 | 0.00 | 0.57 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 2649134.93 | 0.220860E+10 | 0.00 | 934904.49 | 45277332.19 | 0.00 | 35378329.83 | 0.00 | 0.47 |
February | 1897867.67 | 0.306928E+10 | 0.00 | 715038.32 | 69034609.94 | 0.00 | 20446650.48 | 0.00 | 0.47 |
March | 2210851.28 | 0.290245E+10 | 0.00 | 293781.39 | 45363718.08 | 0.00 | 8868414.92 | 0.00 | 0.48 |
April | 1205587.57 | 0.272857E+10 | 0.00 | 97022.15 | 57146911.93 | 0.00 | 2755934.00 | 0.00 | 0.47 |
May | 0.00 | 0.429567E+10 | 0.00 | 0.00 | 70571892.18 | 0.00 | 0.00 | 0.00 | 0.48 |
June | 0.00 | 0.440039E+10 | 0.00 | 0.00 | 68199664.96 | 0.00 | 0.00 | 0.00 | 0.48 |
July | 0.00 | 0.559126E+10 | 0.00 | 0.00 | 65766925.39 | 0.00 | 0.00 | 0.00 | 0.48 |
August | 0.00 | 0.584345E+10 | 0.00 | 0.00 | 75943558.86 | 0.00 | 0.00 | 0.00 | 0.49 |
September | 0.00 | 0.585369E+10 | 0.00 | 0.00 | 69971085.83 | 0.00 | 0.00 | 0.00 | 0.49 |
October | 0.00 | 0.565789E+10 | 0.00 | 0.00 | 82122065.93 | 0.00 | 0.00 | 0.00 | 0.48 |
November | 0.00 | 0.411644E+10 | 0.00 | 0.00 | 66808057.03 | 0.00 | 0.00 | 0.00 | 0.48 |
December | 77586.90 | 0.335137E+10 | 0.00 | 105035.54 | 54262640.07 | 0.00 | 928018.68 | 0.00 | 0.47 |
Annual Sum or Average | 8041028.36 | 0.500191E+11 | 0.00 | 2145781.89 | 0.770468E+09 | 0.00 | 68377347.91 | 0.00 | 0.48 |
Minimum of Months | 0.00 | 0.220860E+10 | 0.00 | 0.00 | 45277332.19 | 0.00 | 0.00 | 0.00 | 0.47 |
Maximum of Months | 2649134.93 | 0.585369E+10 | 0.00 | 934904.49 | 82122065.93 | 0.00 | 35378329.83 | 0.00 | 0.49 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 43009910.77 | 0.183751E+10 | 0.00 | 1018384.59 | 58286865.99 | 0.00 | 80263046.33 | 0.00 | 0.45 |
February | 33113827.43 | 0.250185E+10 | 0.00 | 653035.84 | 0.121688E+09 | 0.00 | 41642118.65 | 0.00 | 0.46 |
March | 36317765.32 | 0.240682E+10 | 0.00 | 576935.65 | 0.103730E+09 | 0.00 | 54263543.23 | 0.00 | 0.46 |
April | 13687529.66 | 0.225122E+10 | 0.00 | 423840.48 | 0.102425E+09 | 0.00 | 25756551.86 | 0.00 | 0.46 |
May | 1585561.51 | 0.357816E+10 | 0.00 | 362723.35 | 0.202790E+09 | 0.00 | 1466216.32 | 0.00 | 0.46 |
June | 0.00 | 0.373144E+10 | 0.00 | 51757.64 | 0.228929E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.462704E+10 | 0.00 | 88813.24 | 0.290049E+09 | 0.00 | 13646.99 | 0.00 | 0.45 |
August | 0.00 | 0.489155E+10 | 0.00 | 195275.75 | 0.306463E+09 | 0.00 | 58235.14 | 0.00 | 0.47 |
September | 10333.51 | 0.471551E+10 | 0.00 | 242159.02 | 0.300328E+09 | 0.00 | 319990.75 | 0.00 | 0.46 |
October | 770398.24 | 0.460644E+10 | 0.00 | 529814.77 | 0.272124E+09 | 0.00 | 3285721.45 | 0.00 | 0.46 |
November | 3768956.28 | 0.347765E+10 | 0.00 | 309395.53 | 0.171548E+09 | 0.00 | 5232362.57 | 0.00 | 0.46 |
December | 8359713.55 | 0.276727E+10 | 0.00 | 642846.57 | 0.133915E+09 | 0.00 | 16783091.98 | 0.00 | 0.45 |
Annual Sum or Average | 0.140624E+09 | 0.413925E+11 | 0.00 | 5094982.42 | 0.229228E+10 | 0.00 | 0.229085E+09 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.183751E+10 | 0.00 | 51757.64 | 58286865.99 | 0.00 | 0.00 | 0.00 | 0.45 |
Maximum of Months | 43009910.77 | 0.489155E+10 | 0.00 | 1018384.59 | 0.306463E+09 | 0.00 | 80263046.33 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 43302164.22 | 0.183071E+10 | 0.00 | 1009894.02 | 57972004.94 | 0.00 | 81668071.93 | 0.00 | 0.45 |
February | 34585892.28 | 0.249522E+10 | 0.00 | 647594.96 | 0.121205E+09 | 0.00 | 40864904.48 | 0.00 | 0.46 |
March | 37311266.76 | 0.240104E+10 | 0.00 | 572434.45 | 0.103432E+09 | 0.00 | 53903608.47 | 0.00 | 0.46 |
April | 13765722.68 | 0.224501E+10 | 0.00 | 425778.68 | 0.101973E+09 | 0.00 | 26111176.82 | 0.00 | 0.46 |
May | 1599487.99 | 0.357553E+10 | 0.00 | 369383.00 | 0.202466E+09 | 0.00 | 1481997.52 | 0.00 | 0.46 |
June | 0.00 | 0.372986E+10 | 0.00 | 56048.42 | 0.228708E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.463462E+10 | 0.00 | 94436.44 | 0.284897E+09 | 0.00 | 14818.49 | 0.00 | 0.45 |
August | 0.00 | 0.489366E+10 | 0.00 | 204293.22 | 0.305845E+09 | 0.00 | 59506.75 | 0.00 | 0.47 |
September | 9106.55 | 0.472250E+10 | 0.00 | 256590.67 | 0.299549E+09 | 0.00 | 319459.98 | 0.00 | 0.46 |
October | 759755.57 | 0.461082E+10 | 0.00 | 546822.98 | 0.271300E+09 | 0.00 | 3261782.93 | 0.00 | 0.46 |
November | 3785745.10 | 0.347482E+10 | 0.00 | 314639.24 | 0.171074E+09 | 0.00 | 5317667.77 | 0.00 | 0.46 |
December | 8381585.46 | 0.276223E+10 | 0.00 | 639095.94 | 0.133532E+09 | 0.00 | 17181140.27 | 0.00 | 0.45 |
Annual Sum or Average | 0.143501E+09 | 0.413760E+11 | 0.00 | 5137012.03 | 0.228195E+10 | 0.00 | 0.230184E+09 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.183071E+10 | 0.00 | 56048.42 | 57972004.94 | 0.00 | 0.00 | 0.00 | 0.45 |
Maximum of Months | 43302164.22 | 0.489366E+10 | 0.00 | 1009894.02 | 0.305845E+09 | 0.00 | 81668071.93 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 46272399.77 | 0.179826E+10 | 0.00 | 961112.37 | 56366959.08 | 0.00 | 85306332.16 | 0.00 | 0.45 |
February | 36433231.57 | 0.245195E+10 | 0.00 | 593463.74 | 0.119799E+09 | 0.00 | 41283448.19 | 0.00 | 0.46 |
March | 44435880.06 | 0.236156E+10 | 0.00 | 504833.61 | 0.101711E+09 | 0.00 | 49727283.35 | 0.00 | 0.46 |
April | 14088133.68 | 0.220894E+10 | 0.00 | 388299.33 | 0.101017E+09 | 0.00 | 27878964.74 | 0.00 | 0.46 |
May | 1590631.19 | 0.353884E+10 | 0.00 | 326261.48 | 0.201692E+09 | 0.00 | 1468160.20 | 0.00 | 0.46 |
June | 0.00 | 0.369556E+10 | 0.00 | 45476.31 | 0.228061E+09 | 0.00 | 0.00 | 0.00 | 0.46 |
July | 0.00 | 0.459972E+10 | 0.00 | 83648.17 | 0.288318E+09 | 0.00 | 13746.49 | 0.00 | 0.45 |
August | 0.00 | 0.485966E+10 | 0.00 | 185976.87 | 0.305537E+09 | 0.00 | 57964.86 | 0.00 | 0.47 |
September | 11567.45 | 0.468562E+10 | 0.00 | 235979.59 | 0.301745E+09 | 0.00 | 325312.10 | 0.00 | 0.46 |
October | 806913.99 | 0.457505E+10 | 0.00 | 504908.01 | 0.271786E+09 | 0.00 | 3584914.40 | 0.00 | 0.46 |
November | 3849776.61 | 0.343863E+10 | 0.00 | 281208.78 | 0.170748E+09 | 0.00 | 5521496.41 | 0.00 | 0.46 |
December | 9434902.99 | 0.272437E+10 | 0.00 | 595118.27 | 0.133037E+09 | 0.00 | 17868147.41 | 0.00 | 0.45 |
Annual Sum or Average | 0.156923E+09 | 0.409382E+11 | 0.00 | 4706286.53 | 0.227982E+10 | 0.00 | 0.233036E+09 | 0.00 | 0.46 |
Minimum of Months | 0.00 | 0.179826E+10 | 0.00 | 45476.31 | 56366959.08 | 0.00 | 0.00 | 0.00 | 0.45 |
Maximum of Months | 46272399.77 | 0.485966E+10 | 0.00 | 961112.37 | 0.305537E+09 | 0.00 | 85306332.16 | 0.00 | 0.47 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 36767827.90 | 0.327310E+10 | 0.00 | 1478992.89 | 63002986.56 | 0.00 | 0.140433E+09 | 0.00 | 0.42 |
February | 21101551.58 | 0.455694E+10 | 0.00 | 798635.44 | 0.118239E+09 | 0.00 | 65255324.16 | 0.00 | 0.42 |
March | 28010090.59 | 0.440538E+10 | 0.00 | 572837.97 | 87647015.94 | 0.00 | 41165434.02 | 0.00 | 0.43 |
April | 13251683.28 | 0.410741E+10 | 0.00 | 356887.15 | 0.107721E+09 | 0.00 | 20212633.71 | 0.00 | 0.42 |
May | 167923.58 | 0.675538E+10 | 0.00 | 246431.92 | 0.180516E+09 | 0.00 | 579021.16 | 0.00 | 0.42 |
June | 0.00 | 0.700246E+10 | 0.00 | 2548.85 | 0.177723E+09 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 395140.20 | 0.877667E+10 | 0.00 | 146022.54 | 0.251746E+09 | 0.00 | 489661.67 | 0.00 | 0.42 |
August | 0.00 | 0.941395E+10 | 0.00 | 101393.23 | 0.228434E+09 | 0.00 | 1571.98 | 0.00 | 0.43 |
September | 0.00 | 0.894653E+10 | 0.00 | 243135.81 | 0.258375E+09 | 0.00 | 250978.56 | 0.00 | 0.42 |
October | 471509.72 | 0.887851E+10 | 0.00 | 309674.33 | 0.249962E+09 | 0.00 | 934218.55 | 0.00 | 0.42 |
November | 6083657.43 | 0.646662E+10 | 0.00 | 55614.62 | 0.140774E+09 | 0.00 | 1854003.60 | 0.00 | 0.42 |
December | 8146492.55 | 0.507978E+10 | 0.00 | 840303.34 | 0.115164E+09 | 0.00 | 14802599.05 | 0.00 | 0.42 |
Annual Sum or Average | 0.114396E+09 | 0.776627E+11 | 0.00 | 5152478.08 | 0.197930E+10 | 0.00 | 0.285979E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.327310E+10 | 0.00 | 2548.85 | 63002986.56 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 36767827.90 | 0.941395E+10 | 0.00 | 1478992.89 | 0.258375E+09 | 0.00 | 0.140433E+09 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 18646695.09 | 0.161748E+10 | 0.00 | 733556.54 | 30026855.06 | 0.00 | 71542060.91 | 0.00 | 0.42 |
February | 12122980.47 | 0.224946E+10 | 0.00 | 395953.92 | 57633200.13 | 0.00 | 31208009.82 | 0.00 | 0.42 |
March | 14306144.54 | 0.217918E+10 | 0.00 | 281802.15 | 42450799.96 | 0.00 | 20569542.02 | 0.00 | 0.43 |
April | 6225808.23 | 0.203573E+10 | 0.00 | 174181.99 | 51859494.76 | 0.00 | 10630892.91 | 0.00 | 0.42 |
May | 89685.60 | 0.335582E+10 | 0.00 | 118370.80 | 87665739.80 | 0.00 | 312257.60 | 0.00 | 0.42 |
June | 0.00 | 0.347933E+10 | 0.00 | 2592.13 | 86663407.44 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 184728.24 | 0.437183E+10 | 0.00 | 68088.86 | 0.119688E+09 | 0.00 | 229872.55 | 0.00 | 0.42 |
August | 0.00 | 0.468763E+10 | 0.00 | 51191.77 | 0.112234E+09 | 0.00 | 3488.33 | 0.00 | 0.43 |
September | 0.00 | 0.444867E+10 | 0.00 | 123743.01 | 0.125946E+09 | 0.00 | 144737.23 | 0.00 | 0.42 |
October | 292206.33 | 0.441548E+10 | 0.00 | 152149.61 | 0.124364E+09 | 0.00 | 499312.75 | 0.00 | 0.42 |
November | 3003812.88 | 0.320705E+10 | 0.00 | 25920.58 | 70966577.62 | 0.00 | 1087809.06 | 0.00 | 0.42 |
December | 4369591.73 | 0.251610E+10 | 0.00 | 390944.84 | 54995838.93 | 0.00 | 7248522.65 | 0.00 | 0.42 |
Annual Sum or Average | 59241653.10 | 0.385638E+11 | 0.00 | 2518496.18 | 0.964494E+09 | 0.00 | 0.143477E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.161748E+10 | 0.00 | 2592.13 | 30026855.06 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 18646695.09 | 0.468763E+10 | 0.00 | 733556.54 | 0.125946E+09 | 0.00 | 71542060.91 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 19218545.59 | 0.160735E+10 | 0.00 | 723839.40 | 29735667.28 | 0.00 | 72968359.82 | 0.00 | 0.42 |
February | 12504847.09 | 0.223561E+10 | 0.00 | 390914.22 | 57294597.77 | 0.00 | 31467233.98 | 0.00 | 0.42 |
March | 14506106.64 | 0.216580E+10 | 0.00 | 275938.40 | 43170231.09 | 0.00 | 21049249.24 | 0.00 | 0.43 |
April | 6836131.40 | 0.202509E+10 | 0.00 | 174929.59 | 51907732.90 | 0.00 | 10433707.32 | 0.00 | 0.42 |
May | 91086.02 | 0.334495E+10 | 0.00 | 115815.84 | 88017622.54 | 0.00 | 312297.03 | 0.00 | 0.42 |
June | 0.00 | 0.346963E+10 | 0.00 | 2110.78 | 86239330.04 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 190120.02 | 0.435942E+10 | 0.00 | 66948.06 | 0.122826E+09 | 0.00 | 237465.89 | 0.00 | 0.42 |
August | 0.00 | 0.467876E+10 | 0.00 | 50623.79 | 0.112031E+09 | 0.00 | 3476.24 | 0.00 | 0.43 |
September | 0.00 | 0.443847E+10 | 0.00 | 121400.80 | 0.126109E+09 | 0.00 | 145544.33 | 0.00 | 0.42 |
October | 302838.42 | 0.440452E+10 | 0.00 | 149945.16 | 0.125508E+09 | 0.00 | 499397.73 | 0.00 | 0.42 |
November | 3016319.25 | 0.319531E+10 | 0.00 | 24994.54 | 70935143.57 | 0.00 | 1126350.62 | 0.00 | 0.42 |
December | 4391156.40 | 0.250351E+10 | 0.00 | 384956.79 | 55166925.57 | 0.00 | 7509759.53 | 0.00 | 0.42 |
Annual Sum or Average | 61057150.83 | 0.384284E+11 | 0.00 | 2482417.35 | 0.968941E+09 | 0.00 | 0.145753E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.160735E+10 | 0.00 | 2110.78 | 29735667.28 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 19218545.59 | 0.467876E+10 | 0.00 | 723839.40 | 0.126109E+09 | 0.00 | 72968359.82 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 20024140.15 | 0.159208E+10 | 0.00 | 690362.96 | 28914880.48 | 0.00 | 76432440.16 | 0.00 | 0.42 |
February | 13723782.50 | 0.221199E+10 | 0.00 | 373554.64 | 55890146.70 | 0.00 | 31583912.80 | 0.00 | 0.42 |
March | 15470507.34 | 0.214505E+10 | 0.00 | 256154.20 | 43253247.86 | 0.00 | 21280368.04 | 0.00 | 0.43 |
April | 7091872.61 | 0.201238E+10 | 0.00 | 165512.61 | 52071758.05 | 0.00 | 11136468.22 | 0.00 | 0.42 |
May | 89188.72 | 0.334241E+10 | 0.00 | 109878.84 | 86766176.90 | 0.00 | 303208.91 | 0.00 | 0.42 |
June | 0.00 | 0.346617E+10 | 0.00 | 483.07 | 87319495.22 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 221865.36 | 0.436137E+10 | 0.00 | 60043.67 | 0.123170E+09 | 0.00 | 234769.63 | 0.00 | 0.42 |
August | 0.00 | 0.468242E+10 | 0.00 | 48882.81 | 0.113396E+09 | 0.00 | 3105.18 | 0.00 | 0.43 |
September | 0.00 | 0.443758E+10 | 0.00 | 116145.79 | 0.127542E+09 | 0.00 | 143992.08 | 0.00 | 0.42 |
October | 239465.25 | 0.440482E+10 | 0.00 | 143206.30 | 0.125776E+09 | 0.00 | 574805.04 | 0.00 | 0.42 |
November | 3175508.16 | 0.318591E+10 | 0.00 | 21125.59 | 70153406.89 | 0.00 | 1097911.02 | 0.00 | 0.42 |
December | 4754335.85 | 0.248791E+10 | 0.00 | 364065.83 | 55649338.63 | 0.00 | 7696976.06 | 0.00 | 0.42 |
Annual Sum or Average | 64790665.94 | 0.383301E+11 | 0.00 | 2349416.33 | 0.969903E+09 | 0.00 | 0.150488E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.159208E+10 | 0.00 | 483.07 | 28914880.48 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 20024140.15 | 0.468242E+10 | 0.00 | 690362.96 | 0.127542E+09 | 0.00 | 76432440.16 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:20:23
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 20449741.99 | 0.166143E+10 | 0.00 | 736453.04 | 19938962.50 | 0.00 | 81266705.56 | 0.00 | 0.42 |
February | 18362824.23 | 0.225140E+10 | 0.00 | 354821.72 | 46015072.51 | 0.00 | 32515821.85 | 0.00 | 0.42 |
March | 24764686.00 | 0.217987E+10 | 0.00 | 259833.44 | 36019647.19 | 0.00 | 18872986.40 | 0.00 | 0.43 |
April | 8686606.87 | 0.210876E+10 | 0.00 | 189118.82 | 40903156.85 | 0.00 | 12604028.78 | 0.00 | 0.42 |
May | 89744.75 | 0.349056E+10 | 0.00 | 153763.43 | 73287467.41 | 0.00 | 323084.11 | 0.00 | 0.42 |
June | 0.00 | 0.361370E+10 | 0.00 | 55368.41 | 65616987.39 | 0.00 | 0.00 | 0.00 | 0.43 |
July | 217061.23 | 0.451321E+10 | 0.00 | 157658.99 | 0.104472E+09 | 0.00 | 1569251.15 | 0.00 | 0.42 |
August | 0.00 | 0.485208E+10 | 0.00 | 50979.89 | 97821729.19 | 0.00 | 551.76 | 0.00 | 0.43 |
September | 0.00 | 0.453833E+10 | 0.00 | 168149.48 | 0.114380E+09 | 0.00 | 145625.82 | 0.00 | 0.42 |
October | 325990.28 | 0.456059E+10 | 0.00 | 179439.98 | 0.107792E+09 | 0.00 | 480941.18 | 0.00 | 0.42 |
November | 3291337.44 | 0.327399E+10 | 0.00 | 79832.87 | 54006884.33 | 0.00 | 1517027.40 | 0.00 | 0.42 |
December | 5532068.39 | 0.256998E+10 | 0.00 | 425325.15 | 46843725.95 | 0.00 | 9168817.79 | 0.00 | 0.42 |
Annual Sum or Average | 81720061.16 | 0.396139E+11 | 0.00 | 2810745.22 | 0.807097E+09 | 0.00 | 0.158465E+09 | 0.00 | 0.42 |
Minimum of Months | 0.00 | 0.166143E+10 | 0.00 | 50979.89 | 19938962.50 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 24764686.00 | 0.485208E+10 | 0.00 | 736453.04 | 0.114380E+09 | 0.00 | 81266705.56 | 0.00 | 0.43 |