Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:10
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904
Simulation Timestamp: 2020-06-03 19:10:41
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 843.49 | 174.45 | 174.45 |
Net Site Energy | 843.49 | 174.45 | 174.45 |
Total Source Energy | 2664.52 | 551.08 | 551.08 |
Net Source Energy | 2664.52 | 551.08 | 551.08 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 3.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 21.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 481.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 123.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 48.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.40 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 840.22 | 3.26 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 3.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 21.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 481.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 123.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 47.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 25.40 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 125.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 19.74 | 0.67 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 173.77 | 0.67 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 125.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 19.74 | 0.67 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 173.77 | 0.67 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 840.223 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 840.223 | 100.00 |
Total On-Site and Utility Electric Sources | 840.223 | 100.00 |
Total Electricity End Uses | 840.223 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 5.00 |
Time Setpoint Not Met During Occupied Cooling | 4.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 184.50 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2007
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3C
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CA_SANDIEGO
| Meter |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| ELECTRIC TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATERHEATINGCOIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATERFAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:10 |
RunPeriod | RUNPERIOD 1 |
Weather File | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Latitude [deg] | 32.58 |
Longitude [deg] | -117.0 |
Elevation [m] | 159.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 34.66 |
Skylight-Roof Ratio [%] | 0.75 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 10.7639 | 47.38 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 8.6111 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 8.6111 | 2.5587 | |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.7166 | 967.03 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.7166 | 967.03 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-SEP-12:00 | 03-JAN-06:10 | - | - | - | 26-JUN-11:30 |
Heating | 0.00 | 33074.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 12980.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 35620.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6194.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1745.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 66653.57 | 33074.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 33074.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 12980.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 35620.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 3889.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1745.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 3.54 | 0.00 | 0.00 | 0.00 |
Cooling | 69.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1526.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 391.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 152.79 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 80.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2660.99 | 3.54 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.73 | 0.00 | 0.00 | 0.00 |
Cooling | 14.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 315.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 80.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 31.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 16.64 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 550.34 | 0.73 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.73 | 0.00 | 0.00 | 0.00 |
Cooling | 14.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 315.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 80.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 31.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 16.64 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 550.34 | 0.73 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 1.05 |
ZONE2 FINE STORAGE DIRECT AIR | 2.46 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3UNITHEATER | 1.23 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATERFAN | 1.23 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATERHEATINGCOIL | 50194.80 |
PSZ-OFFICE HEATING COIL | 25704.83 |
PSZ-FINE STORAGE HEATING COIL | 77420.77 |
User-Specified Heating Design Capacity [W] | |
ZONE3HIRADIANT | 50194.80 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.00 | 1.000000 | 1.05 |
PSZ-FINE STORAGE | 2.46 | 2.46 | 2.46 | 2.46 | 2.46 | 2.46 | 1.00 | 1.00 | 2.46 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE OA CONTROLLER | 1.05 | 0.102285 |
PSZ-FINE STORAGE OA CONTROLLER | 2.46 | 0.424713 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 1.05 | 1.05 | 1.05 | 1.05 | 17333.92 | 25704.83 | 40.00 | 1.00 |
PSZ-FINE_UNITARY_PACKAGE_DX | 2.46 | 2.46 | 2.46 | 2.46 | 49307.65 | 77420.77 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 1.05 | 0.523570 | 1.05 | 17333.89 | 17333.92 | 8666.96 | 17333.92 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-FINE STORAGE COOLING COIL | 2.46 | 1.23 | 2.46 | 46636.31 | 49307.65 | 24653.83 | 49307.65 | 0.735008 | 0.735010 | 0.735010 | 0.735010 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 1.05 | 1193.86 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 2.46 | 2695.79 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE FRONT DOOR | |
OFFICE LEFT WALL | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | OFFICE LEFT WALL DOOR | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.80 | 14.30 | 13.60 | 13.20 | 13.30 | 12.60 | 15.30 | 15.60 | 17.70 | 19.40 | 19.70 | 18.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 | 32.58 | -116.98 | -8.00 | 159.00 | 99429 | 1.1818 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 16.00 | 7.10 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 66 | 42 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 0.00 | 11 | 6 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 14.86 | 6 | 30 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 5.0 | 47.376 | 2.111E-002 | 10.764 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 18.838 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 0.0 | N/A | 0.000 | 8.611 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8.611 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 0.0 | N/A | 0.000 | 8.611 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 11.170 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 5.0 | 2.111E-002 | 47.376 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | BLDG_LIGHT_OFFICE_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 2549.751 | 10.764 | 509.950 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 2549.751 |
2 | FINE STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 11998.830 | 8.611 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 11998.830 |
3 | BULK STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 27597.308 | 8.611 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 27597.308 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 1912.500 | 8.074 | 382.500 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 8200.120 | 2.559 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.3888 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.5959 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL | 19 | 3 | 4 | 0.167 | 0.6999 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL | 21 | 3 | 4 | 0.167 | 1.209 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 32 | 1 | 1 | 0.167 | 3.977 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 33 | 1 | 1 | 0.167 | 3.977 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 35 | 1 | 1 | 0.167 | 8.239 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 36 | 1 | 1 | 0.167 | 2.841 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 37 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 38 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 39 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.1926 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.7922E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.7415E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 43 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL | 44 | 3 | 4 | 0.167 | 1.209 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 45 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.572 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.678 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.329 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7281 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2514 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2514 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.1214 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3520 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.116 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.55 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 13.41 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7281 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.20482715E-10 | 0.21205973E-14 | 0.31184805E-15 | 0.0000000 |
2 | 1 | -5.2160080 | 0.41303701E-04 | -0.41204219E-04 | 0.97833724E-11 |
3 | 0 | 5.6048073 | 0.38875791 | 0.38884042 | |
4 | 2 | 0.53319041E-11 | 0.92099297E-16 | 0.18475806E-15 | 0.0000000 |
5 | 1 | -5.2159728 | 0.43155192E-04 | -0.26885250E-04 | 0.68722794E-11 |
6 | 0 | 5.8118483 | 0.59583229 | 0.59590233 | |
7 | 4 | 0.73826229E-12 | -0.15793949E-15 | 0.14714251E-14 | 0.12610148E-15 |
8 | 3 | -0.37015163E-03 | 0.48261894E-06 | -0.53553847E-04 | 0.14168247E-12 |
9 | 2 | 1.7048811 | 0.10720623E-01 | 1.1141045 | -0.70963114E-04 |
10 | 1 | -7.1749370 | 0.28051356 | -16.929564 | 0.32672988 |
11 | 0 | 5.9416824 | 0.18002168 | 16.286769 | |
12 | 4 | 0.64162135E-12 | 0.65646114E-15 | -0.12904024E-14 | 0.12678731E-15 |
13 | 3 | -0.33584230E-03 | 0.79457704E-06 | -0.48268613E-04 | 0.12317170E-12 |
14 | 2 | 1.6213285 | 0.18378730E-01 | 1.0506728 | -0.64380977E-04 |
15 | 1 | -7.2911921 | 0.49313376 | -16.520002 | 0.31060912 |
16 | 0 | 6.5034338 | 0.32172104 | 16.302612 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 3.9772727 | 3.9772727 | 3.9772727 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 3.9772727 | 3.9772727 | 3.9772727 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 8.2386364 | 8.2386364 | 8.2386364 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 2.8409091 | 2.8409091 | 2.8409091 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.21936956E-08 | -0.76657665E-15 | 0.52174295E-14 | -0.76362207E-16 |
55 | 6 | 0.54250385E-05 | 0.36865710E-08 | 0.31904099E-02 | -0.26763832E-04 |
56 | 5 | -0.38781740E-03 | 0.21819055E-05 | -0.22375527 | 0.19564212E-02 |
57 | 4 | 0.89061350E-02 | 0.99303795E-04 | 4.8300570 | -0.45269896E-01 |
58 | 3 | -0.78164548E-01 | 0.78949647E-03 | -38.024306 | 0.39868569 |
59 | 2 | 0.27748674 | 0.13132576E-02 | 116.48957 | -1.4180145 |
60 | 1 | -0.40047331 | 0.39992572E-03 | -143.91062 | 2.0490943 |
61 | 0 | 0.19524127 | 0.97244710E-05 | 60.838472 | |
62 | 7 | -0.53942680E-08 | -0.11156834E-13 | 0.16318657E-14 | -0.36257882E-16 |
63 | 6 | 0.25438785E-05 | 0.15223906E-08 | 0.31992327E-02 | -0.26837845E-04 |
64 | 5 | -0.16605865E-03 | 0.89659996E-06 | -0.22425660 | 0.19608463E-02 |
65 | 4 | 0.37075836E-02 | 0.40698259E-04 | 4.8384045 | -0.45350141E-01 |
66 | 3 | -0.32199378E-01 | 0.32283529E-03 | -38.071448 | 0.39920679 |
67 | 2 | 0.11382527 | 0.53586778E-03 | 116.58131 | -1.4192416 |
68 | 1 | -0.16395953 | 0.16275009E-03 | -143.96461 | 2.0499819 |
69 | 0 | 0.79856572E-01 | 0.39490086E-05 | 60.838472 | |
70 | 7 | -0.57660871E-08 | -0.13610624E-13 | 0.89936022E-15 | -0.28491615E-16 |
71 | 6 | 0.24333103E-05 | 0.14269892E-08 | 0.31996257E-02 | -0.26841142E-04 |
72 | 5 | -0.15663594E-03 | 0.83977476E-06 | -0.22427892 | 0.19610433E-02 |
73 | 4 | 0.34808858E-02 | 0.38103208E-04 | 4.8387759 | -0.45353710E-01 |
74 | 3 | -0.30176241E-01 | 0.30214868E-03 | -38.073544 | 0.39922996 |
75 | 2 | 0.10659492 | 0.50136596E-03 | 116.58539 | -1.4192962 |
76 | 1 | -0.15349297 | 0.15221123E-03 | -143.96701 | 2.0500213 |
77 | 0 | 0.74745977E-01 | 0.36906361E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.12904024E-14 | 0.65646114E-15 | 0.64162135E-12 | 0.12678731E-15 |
85 | 3 | -0.48268613E-04 | 0.79457704E-06 | -0.33584230E-03 | 0.12317170E-12 |
86 | 2 | 1.0506728 | 0.18378730E-01 | 1.6213285 | -0.64380977E-04 |
87 | 1 | -16.520002 | 0.49313376 | -7.2911921 | 0.31060912 |
88 | 0 | 16.302612 | 0.32172104 | 6.5034338 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.63_SHGC_0.25 | 28 | 1 | VerySmooth | 3.582 | 0.253 | 0.153 | 0.250 |
2 | SKYLIGHT_U_1.02_SHGC_0.39 | 29 | 1 | VerySmooth | 5.779 | 0.390 | 0.223 | 0.391 |
3 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 30 | 1 | VerySmooth | 5.779 | 0.550 | 0.397 | 0.551 |
4 | SKYLIGHT DOUBLE CLEAR | 34 | 3 | VerySmooth | 3.715 | 0.720 | 0.644 | 0.817 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.15304 | 0.57918 | 0.57918 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 1.81224E-002 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.22227 | 0.21773 | 0.21773 | 0.39000 | 0.13867 | 0.18233 | 0.00000 | 0.84000 | 0.84000 | 0.30192 | 1.00000 | No | |
3 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.39618 | 8.78068E-002 | 8.78068E-002 | 0.55000 | 0.12964 | 0.15485 | 0.00000 | 0.84000 | 0.84000 | 0.30192 | 1.00000 | No | |
4 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
5 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 20 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | ELECTRIC TANK | 7.5708E-002 | 6154.7 | 1.052 | 0.5205 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 5.0 | 6.083E-002 | 2.568E-004 | 3.964E-004 | 0.217 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 0.177 | 7.451E-004 | 1.150E-003 | 0.629 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 0.889 | 6.381E-004 | 4.064E-004 | 1.084 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 3.431 | 1.071E-003 | 6.993E-004 | 0.350 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 37.760 | 1.178E-002 | N/A | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 0.944 | 2.945E-004 | N/A | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 10410.08317 | 12492.09980 | 0.87262 | 1.04714 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 30.29133 | 8.20219E-003 | 236.87965 | 5.00000 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 8130.54601 | 9756.65521 | 0.23241 | 0.27889 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 3.80000 | 5.05843E-003 | 236.87965 | 5.00000 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 31412.47060 | 37694.96472 | 2.05252 | 2.46302 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 31.30000 | 8.20219E-003 | 1393.40969 | 0.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 21731.29729 | 26077.55675 | 0.52358 | 0.62829 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 3.80000 | 5.05843E-003 | 1393.40969 | 0.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 31.30000 | 8.20219E-003 | 3204.84228 | 0.00000 | 0.97684 | 0.00000 | |
6 | ZONE3 BULK STORAGE | Heating | 41829.00010 | 50194.80012 | 1.02623 | 1.23148 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 3204.84228 | 0.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 15573.53 | 1.04714 | 1.04714 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 8379.67 | 0.27889 | 0.27889 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 45315.75 | 2.46302 | 2.46302 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 24166.72 | 0.62829 | 0.62829 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.04714 |
2 | AirTerminal:SingleDuct:Uncontrolled | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.46302 |
3 | ZoneHVAC:UnitHeater | ZONE3UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.23148 |
4 | Fan:ConstantVolume | ZONE3UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 1.23148 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 50194.80129 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3HIRADIANT | User-Specified Heating Design Capacity [W] | 50194.80012 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.04714 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.04714 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.04714 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.04714 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.04714 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 1.04714 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.46302 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.46302 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.46302 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 2.46302 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.46302 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 2.46302 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 1.04714 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 2.46302 |
25 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.04714 |
26 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.04714 |
28 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.04714 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.04714 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.04714 |
31 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.04714 |
32 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52357 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.04714 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17333.88512 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17333.92000 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8666.96000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17333.92000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
40 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
41 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17333.92000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25704.82854 |
44 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
45 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
46 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.04714 |
47 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1193.85729 |
48 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 25704.82854 |
49 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.46302 |
50 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.46302 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.46302 |
53 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.46302 |
54 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.46302 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.46302 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.23151 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.46302 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 46636.30771 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 49307.65000 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 24653.82500 |
61 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 49307.65000 |
62 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.73501 |
63 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.73501 |
64 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.73501 |
65 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.73501 |
66 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 49307.65000 |
67 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 77420.77205 |
68 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
69 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
70 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.46302 |
71 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2695.79172 |
72 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 77420.77205 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 16521.4 | 11.07 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 47395.1 | 13.29 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | ML KING BIRTHDAY | Holiday | InputFile | 01/16 | 1 |
3 | WASHINGTON'S BIRTHDAY | Holiday | InputFile | 02/20 | 1 |
4 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
5 | FOURTH OF JULY | Holiday | InputFile | 07/04 | 1 |
6 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
7 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
8 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
9 | THANKSGIVING DAY | Holiday | InputFile | 11/23 | 1 |
10 | CHRISTMAS DAY | Holiday | InputFile | 12/25 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 11 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 2.3110877310E-002 | 1.9007116454E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.1180524607 | 0.1536294572 | Pass | Pass | 0.4507537598 | 2.8339883409 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 3.6374136870E-002 | 3.9010555467E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00 | 3.80 | Wetbulb [C] | 3.00 | 120.00 |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 31.30 | 8.90 | 18.40 | Wetbulb [C] | 4.10 | 280.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 39.02 | 30.56 | 0.00 | 90.00 | N |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.369 | 0.389 | 1393.41 | 1393.41 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL | 0.30 | 1.023 | 1.209 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL | 0.30 | 1.023 | 1.209 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL | 0.30 | 1.023 | 1.209 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.551 | 0.596 | 3204.84 | 3170.19 | 270.00 | 0.00 | |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.193 | 236.88 | 236.88 | 90.00 | 180.00 | ||
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.079 | 1156.53 | 1156.53 | 90.00 | 180.00 | ||
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.074 | 3204.84 | 3204.84 | 90.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.63_SHGC_0.25 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 3.582 | 0.253 | 0.250 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.63_SHGC_0.25 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 3.582 | 0.253 | 0.250 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.63_SHGC_0.25 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 3.582 | 0.253 | 0.250 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.63_SHGC_0.25 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 3.582 | 0.253 | 0.250 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C5 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C5 | SEMIHTDSKYLIGHT_U_1.02_SHGC_0.55 | 1.49 | 1.98 | 0.00 | 3.47 | 3.47 | 5.779 | 0.550 | 0.551 | 283.913 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
Total or Average | 52.32 | 5.037 | 0.450 | 0.449 | ||||||||||||
North Total or Average | 6.51 | 3.582 | 0.253 | 0.250 | ||||||||||||
Non-North Total or Average | 45.81 | 5.244 | 0.477 | 0.478 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 2.493 | 3.977 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 2.493 | 3.977 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 2.493 | 3.977 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.993 | 2.841 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 2.493 | 3.977 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 2.493 | 3.977 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 2.493 | 3.977 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 2.493 | 3.977 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 2.493 | 3.977 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 3.689 | 8.239 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 2.493 | 3.977 | 1.95 | BULK STORAGE LEFT WALL |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | 10.7639 | 236.88 | 2549.75 | LightsWired | BLDG_LIGHT_OFFICE_SCH | 65.78 | 168.00 | 64.76 | 0.0000 | Y | 30.99 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | 8.6111 | 1393.41 | 11998.83 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 136.66 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | 8.6111 | 3204.84 | 27597.31 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 314.31 |
Interior Lighting Total | 8.7166 | 4835.13 | 42145.89 | 481.96 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7857.24 | AstronomicalClock | - | 83.75 | 83.75 | 123.53 | |
Exterior Lighting Total | 7857.24 | 123.53 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 17333.92 | 13843.91 | 3490.01 | 0.80 | 3.91 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 49307.65 | 36241.62 | 13066.03 | 0.74 | 3.30 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 16521.4 | 11.07 | ||||
PSZ-FINE STORAGE COOLING COIL | 47395.1 | 13.29 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATERHEATINGCOIL | Coil:Heating:Fuel | 50194.80 | 0.80 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 25704.83 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 77420.77 | 0.79 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 1.23 | 114.42 | 92.91 | 1.00 | 3.94 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.55 | 622.50 | 1.05 | 1193.86 | 1140.11 | 1.00 | 1.35 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.57 | 622.50 | 2.46 | 2695.79 | 1094.51 | 1.00 | 1.26 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
ELECTRIC TANK | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.05 | 0.52 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 10410.08 | 12492.10 | 52.74 | 0.873 | 1.047 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 23.90 | 23.90 | 0.00812 | 30.29 | 0.00820 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 31412.47 | 37694.96 | 27.05 | 2.053 | 2.463 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 26.70 | 26.70 | 0.00802 | 31.30 | 0.00820 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 10.00 | 0.00 | 0.00385 | 31.30 | 0.00820 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 8130.55 | 9756.66 | 41.19 | 0.232 | 0.279 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00772 | 3.80 | 0.00506 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 21731.30 | 26077.56 | 18.71 | 0.524 | 0.628 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 15.56 | 15.56 | 0.00666 | 3.80 | 0.00506 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 41829.00 | 50194.80 | 15.66 | 1.026 | 1.231 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 10.00 | 10.00 | 0.00778 | 3.80 | 0.00506 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 1.05 | 1.05 | 0.28 | 0.28 | 1.0471 | 1.0471 | 1.0471 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 2.46 | 2.46 | 0.63 | 0.63 | 2.4630 | 2.4630 | 2.4630 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | 50194.801 | 50194.801 | -999.0 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 50194.80 | 50194.80 | 1.231477 | 5.08 | 5.08 | 0.00562029 | 43.33 | 26.86 | 0.01600000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 10.00 | 0.00777570 | 100.0000 | 50194.80 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 17333.920 | 0.000 | 1.047140 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 17333.92 | 16956.48 | 1.047140 | 24.52 | 16.04 | 0.00812575 | 12.00 | 11.09 | 0.00800000 | 30.29 | 0.00820219 | 18.07 | 9.7680 | 23.90 | 0.00811748 | 43.1704 | 10410.08 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 25704.829 | 25704.829 | -999.0 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 25704.83 | 25704.83 | 1.047142 | 14.70 | 10.93 | 0.00674285 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 9.7680 | 21.10 | 0.00771844 | 48.6940 | 8130.55 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 49307.650 | 0.000 | 2.463020 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 49307.65 | 48934.97 | 2.463020 | 27.49 | 17.01 | 0.00805197 | 12.00 | 11.09 | 0.00800000 | 31.30 | 0.00820219 | 18.40 | 17.2436 | 26.70 | 0.00802067 | 36.1163 | 31412.47 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 77420.772 | 77420.772 | -999.0 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 77420.77 | 77420.77 | 2.463023 | 7.61 | 6.39 | 0.00557653 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 17.2436 | 15.56 | 0.00665739 | 59.5708 | 21731.30 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 50194.801 | 50194.801 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1034.5832 | 1004.8586 | 1.1818 | ZONE3UNITHEATERFAN | Fan:ConstantVolume | 1.231477 | 1.45533340 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 50194.80 | 50194.80 | 1.0000 | 1.45533340 | 1.231477 | 5.08 | 5.08 | 0.00562029 | 19214.9 | 43.33 | 26.86 | 0.01600000 | 84847.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 50194.80 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 10.00 | 0.00777570 | 10.00 | 0.00777570 | 100.0000 | 50194.80 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17333.920 | 0.000 | 1.047140 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9454 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 17333.92 | 16956.48 | 1.0000 | 1.23748771 | 1.047140 | 24.52 | 16.04 | 0.00812575 | 45335.1 | 12.00 | 11.09 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17333.92 | 30.29 | 0.00820219 | 18.07 | 0.10228487 | 9.7680 | 23.90 | 0.00811748 | 23.90 | 0.00811748 | 43.1704 | 10410.08 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25704.829 | 25704.829 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.047142 | 1.23749043 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 25704.83 | 25704.83 | 1.0000 | 1.23749043 | 1.047142 | 14.70 | 10.93 | 0.00674285 | 31816.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25704.83 | 3.80 | 0.00505843 | 3.80 | 0.10228487 | 9.7680 | 21.01 | 0.00771844 | 21.10 | 0.00771844 | 48.6940 | 8130.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 49307.650 | 0.000 | 2.463020 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8082 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 49307.65 | 48934.97 | 1.0000 | 2.91074448 | 2.463020 | 27.49 | 17.01 | 0.00805197 | 48175.2 | 12.00 | 11.09 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 49307.65 | 31.30 | 0.00820219 | 18.40 | 0.42471267 | 17.2436 | 26.70 | 0.00802067 | 26.70 | 0.00802067 | 36.1163 | 31412.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 77420.772 | 77420.772 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.463023 | 2.91074751 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 77420.77 | 77420.77 | 1.0000 | 2.91074751 | 2.463023 | 7.61 | 6.39 | 0.00557653 | 21672.1 | 40.00 | 20.93 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 77420.77 | 3.80 | 0.00505843 | 3.80 | 0.42471267 | 17.2436 | 15.56 | 0.00665739 | 15.56 | 0.00665739 | 59.5708 | 21731.30 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-FINE STORAGE OA CONTROLLER | DifferentialDryBulb | 0.42 | 2.46 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 1254.50 | 1946.83 | 184.50 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 |
Facility | 1254.50 | 1946.83 | 184.50 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 5.00 | 67.17 | 5.00 | 4.00 |
ZONE2 FINE STORAGE | 2.17 | 3.83 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 7.17 | 71.00 | 5.00 | 4.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.74 | 5.00 | 1010.76 | 0.343 | 0.247 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.74 | 5.00 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 14 | 14 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
Electricity:Building | 621.73 | 4992.32 | 01-JAN-00:10 | 48037.94 | 19-JUL-10:20 |
Electricity:Zone:ZONE1 OFFICE | 62.94 | 1032.71 | 01-JAN-00:10 | 3875.81 | 02-JAN-08:10 |
InteriorLights:Electricity | 481.96 | 4418.57 | 01-JAN-00:10 | 35620.03 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 30.99 | 458.96 | 01-JAN-00:10 | 1963.31 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 481.96 | 4418.57 | 01-JAN-00:10 | 35620.03 | 02-JAN-09:10 |
Electricity:Zone:ZONE2 FINE STORAGE | 136.66 | 1199.88 | 01-JAN-00:10 | 10199.01 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 136.66 | 1199.88 | 01-JAN-00:10 | 10199.01 | 02-JAN-09:10 |
Electricity:Zone:ZONE3 BULK STORAGE | 422.14 | 2759.73 | 01-JAN-00:10 | 33963.13 | 19-JUL-10:20 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 314.31 | 2759.73 | 01-JAN-00:10 | 23457.71 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Electricity:Plant | 25.40 | 483.00 | 05-JAN-06:10 | 1805.21 | 01-FEB-12:10 |
WaterSystems:Electricity | 25.40 | 483.00 | 05-JAN-06:10 | 1805.21 | 01-FEB-12:10 |
Water Heater:WaterSystems:Electricity | 25.40 | 483.00 | 05-JAN-06:10 | 1805.21 | 01-FEB-12:10 |
Fans:Electricity | 48.25 | 0.00 | 01-JAN-00:10 | 6194.94 | 16-OCT-10:00 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.49 | 0.00 | 01-JAN-00:10 | 2305.29 | 15-OCT-13:30 |
Ventilation (simple):Fans:Electricity | 0.49 | 0.00 | 01-JAN-00:10 | 2305.29 | 15-OCT-13:30 |
ElectricityPurchased:Facility | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
ElectricityPurchased:Plant | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
Cogeneration:ElectricityPurchased | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
ElectricityNet:Plant | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
Cogeneration:ElectricityNet | 840.22 | 5475.32 | 01-JAN-07:10 | 66653.57 | 29-SEP-13:00 |
Electricity:HVAC | 69.56 | 0.00 | 01-JAN-00:10 | 17350.20 | 16-OCT-11:20 |
General:Fans:Electricity | 47.75 | 0.00 | 01-JAN-00:10 | 3889.65 | 08-APR-14:20 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 21.80 | 0.00 | 01-JAN-00:10 | 13460.55 | 16-OCT-11:20 |
ExteriorLights:Electricity | 123.53 | 0.00 | 01-JAN-07:00 | 7857.24 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 123.53 | 0.00 | 01-JAN-07:00 | 7857.24 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 3.26 | 0.00 | 01-JAN-00:10 | 33074.93 | 03-JAN-06:10 |
Gas:HVAC | 3.26 | 0.00 | 01-JAN-00:10 | 33074.93 | 03-JAN-06:10 |
Heating:Gas | 3.26 | 0.00 | 01-JAN-00:10 | 33074.93 | 03-JAN-06:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 26-JUN-11:30 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 181.16 | 0.00 | 01-JAN-00:10 | 71465.18 | 16-OCT-12:00 |
EnergyTransfer:Building | 93.05 | 0.00 | 01-JAN-00:10 | 30676.33 | 16-OCT-12:00 |
EnergyTransfer:Zone:ZONE1 OFFICE | 41.94 | 0.00 | 01-JAN-00:10 | 12954.29 | 03-JAN-06:10 |
Heating:EnergyTransfer | 6.33 | 0.00 | 01-JAN-00:10 | 24043.54 | 03-JAN-06:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 1.96 | 0.00 | 01-JAN-00:10 | 12954.29 | 03-JAN-06:10 |
Cooling:EnergyTransfer | 86.72 | 0.00 | 01-JAN-00:10 | 30676.33 | 16-OCT-12:00 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 39.98 | 0.00 | 01-JAN-00:10 | 8671.56 | 16-OCT-11:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 51.10 | 0.00 | 01-JAN-00:10 | 23205.99 | 30-SEP-13:50 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 4.37 | 0.00 | 01-JAN-00:10 | 15990.55 | 03-JAN-02:10 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 46.74 | 0.00 | 01-JAN-00:10 | 23205.99 | 30-SEP-13:50 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 88.11 | 0.00 | 01-JAN-00:10 | 43383.75 | 31-JUL-14:20 |
HeatingCoils:EnergyTransfer | 2.21 | 0.00 | 01-JAN-00:10 | 24496.70 | 03-JAN-06:10 |
CoolingCoils:EnergyTransfer | 85.90 | 0.00 | 01-JAN-00:10 | 43383.75 | 31-JUL-14:20 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 1.961 | -39.983 | 0.000 | 0.000 | 3.632 | 30.994 | 31.946 | 8.665 | 0.000 | 0.148 | 0.000 | 0.000 | -8.783 | 0.000 | -9.057 | -19.523 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 4.368 | -46.736 | 0.000 | 0.000 | 0.000 | 136.656 | 0.000 | 0.000 | 0.000 | 0.396 | 0.001 | 0.000 | 0.000 | 0.000 | -67.958 | -26.727 |
ZONE3 BULK STORAGE | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 314.310 | 107.336 | 46.353 | 0.000 | 5.311 | 0.011 | 0.000 | -20.219 | 0.000 | -343.809 | -109.282 |
Total Facility | 0.000 | 0.000 | 6.330 | -86.720 | 0.000 | 0.000 | 3.632 | 481.960 | 139.282 | 55.018 | 0.000 | 5.855 | 0.012 | 0.000 | -29.003 | 0.000 | -420.823 | -155.532 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 05-JUL-00:01 | 0.00 | 0.00 | 0.00 | -16162.13 | 0.00 | 0.00 | 0.00 | 458.96 | 573.75 | 0.00 | 0.00 | 0.00 | 15658.28 | 0.00 | -528.85 | 0.00 | 0.00 | 0.00 |
ZONE2 FINE STORAGE | 04-JUL-16:51 | 0.00 | 0.00 | 0.00 | -49148.17 | 0.00 | 0.00 | 0.00 | 1199.88 | 0.00 | 0.00 | 0.00 | 0.00 | 47948.29 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 15-JUL-17:11 | 0.00 | 0.00 | 0.00 | -57402.71 | 0.00 | 0.00 | 0.00 | 4418.57 | 2623.78 | 2656.88 | 0.00 | 0.00 | 47703.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 02-JAN-06:01 | 0.00 | 0.00 | 25375.87 | 0.00 | 0.00 | 0.00 | 56.10 | 586.44 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -308.76 | 0.00 | -373.95 | -25909.45 |
ZONE2 FINE STORAGE | 02-JAN-06:07 | 0.00 | 0.00 | 61835.58 | 0.00 | 0.00 | 0.00 | 0.00 | 1199.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -2432.83 | -60602.63 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 03-JAN-06:01 | 0.00 | 0.00 | 85880.01 | 0.00 | 0.00 | 0.00 | 55.98 | 4546.06 | 2623.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2051.86 | 0.00 | -12365.23 | -78688.74 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.0471 | 0.0000 | 5.0000 | 1.0000 | 0.1023 | 1.0471 | 0.0977 | 1.0000 | 0.1023 | 0.0977 | ||
PSZ-FINE STORAGE | 2.4630 | 0.0000 | 0.0000 | 1.0000 | 0.4247 | 2.4630 | 0.1724 | 1.0000 | 0.4247 | 0.1724 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.0471 | 0.0000 | 5.0000 | 1.0000 | 0.1023 | 1.0471 | 1.0000 | 1.0000 | 0.1023 | 0.0977 | ||
PSZ-FINE STORAGE | 2.4630 | 0.0000 | 0.0000 | 1.0000 | 0.4247 | 2.4630 | 1.0000 | 1.0000 | 0.4247 | 0.1724 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 5.0000 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 0.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 5.00 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 1.0471 | 1.0471 | 1.0471 | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 2.4630 | 2.4630 | 2.4630 | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.0471 | 1.0471 | 1.0471 | 1.0471 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.4630 | 2.4630 | 2.4630 | 2.4630 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 1.0471 | 1.0471 | 1.0471 | 0.1023 | 0.3668 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 2.4630 | 2.4630 | 2.4630 | 0.4247 | 0.6760 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.0471 | 1.0471 | 1.0471 | 1.0471 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.4630 | 2.4630 | 2.4630 | 2.4630 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:10:41
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 0.00 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 5.00 |
Number of hours cooling loads not met | 4.00 |
Number of hours not met | 9.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 3.26 | 33074.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 21.80 | 13460.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 481.96 | 35620.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 123.53 | 7857.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.28 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.49 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 47.75 | 3889.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 25.40 | 1805.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.28 | 840.22 |
Natural Gas | 0.00 | 3.26 |
Additional | 0.00 | 0.00 |
Total | 139.28 | 843.49 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 99.68 |
Space Heating | 0.00 |
Space Cooling | 4.51 |
Fans (All) | 9.98 |
Service Water Heating | 5.25 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 173.77 |
Subtotal | 173.77 |
Natural Gas [MJ/m2] | |
Space Heating | 0.67 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 0.67 |
Subtotal | 0.67 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 57.14 |
Space Heating | 0.39 |
Space Cooling | 2.58 |
Fans (All) | 5.72 |
Service Water Heating | 3.01 |
Receptacle Equipment | 16.51 |
Miscellaneous | 14.65 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
OFFICE LIGHT SCHEDULE | 3792. | 8760. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
STORAGE LIGHT SCHEDULE | 3232. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
OFFICE LIGHT WITH SENSOR SCHEDULE | 3430. | 8760. |
STORAGE LIGHT WITH SENSOR SCHEDULE | 2877. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BLDG_LIGHT_OFFICE_SCH | 3430. | 8760. |
BLDG_LIGHT_STORAGE_SCH | 3232. | 8760. |
BLDG_OCC_SCH | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1121. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | HEATING SETPOINT WITH SB | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | July | 23.90 | 365 | 23.90 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2007
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3C
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CA_SANDIEGO
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.155704E+10 |
February | 0.000 | 0.394420E+09 |
March | 0.000 | 0.676089E+09 |
April | 0.000 | 0.512498E+08 |
May | 0.000 | 3202742.175 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.128279E+09 |
December | 0.000 | 0.451792E+09 |
Annual Sum or Average | 0.326207E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.155704E+10 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.869396E+09 | 3635.03 | 21-JAN-15:30 | 14.00 | 10.94 | 0.235729E+09 | 301.61 | 07-JAN-13:09 | 18.67 | 10.52 |
February | 0.770010E+09 | 3670.85 | 03-FEB-15:10 | 22.67 | 9.05 | 0.218673E+09 | 301.60 | 01-FEB-15:39 | 19.00 | 15.50 |
March | 0.103695E+10 | 6401.36 | 23-MAR-17:20 | 18.33 | 15.42 | 0.255826E+09 | 301.60 | 25-MAR-14:09 | 13.50 | 12.05 |
April | 0.279512E+10 | 12140.45 | 26-APR-17:10 | 21.50 | 16.58 | 0.246215E+09 | 301.69 | 17-APR-07:00 | 16.00 | 11.05 |
May | 0.346464E+10 | 14443.86 | 01-MAY-00:03 | 15.20 | 14.50 | 0.257570E+09 | 301.61 | 02-MAY-15:50 | 19.50 | 15.47 |
June | 0.514614E+10 | 15439.36 | 26-JUN-00:01 | 17.00 | 15.07 | 0.258685E+09 | 301.61 | 17-JUN-14:39 | 22.33 | 16.49 |
July | 0.680581E+10 | 16162.74 | 05-JUL-00:01 | 16.00 | 14.12 | 0.248934E+09 | 301.61 | 06-JUL-15:20 | 21.67 | 16.73 |
August | 0.691538E+10 | 14837.90 | 19-AUG-17:43 | 23.17 | 17.32 | 0.268843E+09 | 301.61 | 29-AUG-15:50 | 22.17 | 16.89 |
September | 0.512847E+10 | 14594.32 | 05-SEP-00:02 | 14.83 | 13.63 | 0.248838E+09 | 301.61 | 16-SEP-14:30 | 21.00 | 15.96 |
October | 0.446651E+10 | 15754.21 | 16-OCT-00:01 | 21.67 | 10.86 | 0.248106E+09 | 303.01 | 23-OCT-07:10 | 17.13 | 14.55 |
November | 0.152993E+10 | 3895.08 | 18-NOV-15:30 | 23.50 | 13.89 | 0.234263E+09 | 301.60 | 08-NOV-16:49 | 17.33 | 15.05 |
December | 0.105509E+10 | 3882.20 | 05-DEC-15:30 | 24.00 | 12.81 | 0.240100E+09 | 305.69 | 18-DEC-09:00 | 23.00 | 9.64 |
Annual Sum or Average | 0.399834E+11 | 0.296178E+10 | ||||||||
Minimum of Months | 0.770010E+09 | 3635.03 | 14.00 | 9.05 | 0.218673E+09 | 301.60 | 13.50 | 9.64 | ||
Maximum of Months | 0.691538E+10 | 16162.74 | 24.00 | 17.32 | 0.268843E+09 | 305.69 | 23.00 | 16.89 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.498352E+09 | 7866.85 | 12-JAN-07:10 | 7.00 | 7.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.575294E+09 | 6932.21 | 28-FEB-07:10 | 11.33 | 9.16 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.938082E+09 | 10248.68 | 10-MAR-07:10 | 10.67 | 7.38 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.218428E+10 | 45750.46 | 30-APR-14:51 | 23.00 | 16.65 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.255603E+10 | 13184.26 | 03-MAY-13:00 | 24.00 | 15.03 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.600162E+10 | 44744.82 | 25-JUN-14:21 | 21.50 | 16.68 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.113837E+11 | 49152.40 | 04-JUL-16:51 | 19.00 | 15.26 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.112239E+11 | 42868.69 | 20-AUG-15:51 | 22.00 | 17.39 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.589764E+10 | 46163.11 | 03-SEP-12:51 | 22.00 | 16.39 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.423928E+10 | 42415.45 | 15-OCT-13:43 | 31.17 | 15.31 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.654064E+09 | 8790.61 | 29-NOV-07:10 | 13.33 | 4.13 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.584074E+09 | 9968.64 | 23-DEC-07:10 | 6.33 | 2.87 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.467363E+11 | 0.00 | ||||||||
Minimum of Months | 0.498352E+09 | 6932.21 | 6.33 | 2.87 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.113837E+11 | 49152.40 | 31.17 | 17.39 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 | 8.36 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 15.20 | 14.50 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 | 17.39 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 7.63 | 5.43 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.00 | 0.00 | 18.42 | 17.39 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.615495E+09 | 25375.97 | 02-JAN-06:01 | 11.00 |
February | 0.318294E+09 | 24690.33 | 28-FEB-06:01 | 10.17 |
March | 0.444414E+09 | 24631.53 | 01-MAR-06:01 | 7.00 |
April | 49150253.64 | 24579.90 | 01-APR-05:01 | 7.83 |
May | 15744697.80 | 1126.31 | 15-MAY-06:10 | 11.33 |
June | 9525260.02 | 582.23 | 19-JUN-06:10 | 17.17 |
July | 1553973.85 | 592.55 | 03-JUL-06:10 | 18.00 |
August | 1673293.81 | 644.64 | 30-AUG-06:10 | 18.00 |
September | 5785168.57 | 554.76 | 21-SEP-06:10 | 17.17 |
October | 9807891.30 | 1239.41 | 04-OCT-06:05 | 20.17 |
November | 0.126265E+09 | 24262.69 | 27-NOV-06:02 | 10.67 |
December | 0.363530E+09 | 24704.54 | 16-DEC-06:02 | 12.17 |
Annual Sum or Average | 0.196124E+10 | |||
Minimum of Months | 1553973.85 | 554.76 | 7.00 | |
Maximum of Months | 0.615495E+09 | 25375.97 | 20.17 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.116981E+10 | 61836.10 | 02-JAN-06:07 | 11.00 |
February | 0.290022E+09 | 2896.60 | 27-FEB-08:00 | 9.00 |
March | 0.353150E+09 | 20249.69 | 30-MAR-04:40 | 4.73 |
April | 0.278211E+09 | 2596.69 | 21-APR-07:00 | 13.00 |
May | 0.204136E+09 | 2784.98 | 25-MAY-07:00 | 14.00 |
June | 0.193377E+09 | 2679.43 | 06-JUN-07:00 | 17.00 |
July | 0.142385E+09 | 2488.76 | 12-JUL-07:00 | 17.00 |
August | 0.200369E+09 | 2555.32 | 21-AUG-07:00 | 17.00 |
September | 0.194938E+09 | 2755.05 | 27-SEP-07:00 | 16.00 |
October | 0.251757E+09 | 3264.62 | 14-OCT-08:65 | 27.67 |
November | 0.397425E+09 | 2730.02 | 01-NOV-07:00 | 11.00 |
December | 0.692788E+09 | 3122.05 | 16-DEC-13:00 | 26.00 |
Annual Sum or Average | 0.436836E+10 | |||
Minimum of Months | 0.142385E+09 | 2488.76 | 4.73 | |
Maximum of Months | 0.116981E+10 | 61836.10 | 27.67 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.259236E+10 | 1963.31 | 02-JAN-08:09 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.236435E+10 | 1963.31 | 01-FEB-08:09 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.270141E+10 | 1963.31 | 01-MAR-08:09 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.255271E+10 | 1963.31 | 01-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.264689E+10 | 1963.31 | 01-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.260723E+10 | 1963.31 | 01-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.259236E+10 | 1963.31 | 01-JUL-07:10 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.270141E+10 | 1963.31 | 01-AUG-07:10 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.255271E+10 | 1963.31 | 01-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.259236E+10 | 1963.31 | 02-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.249819E+10 | 1963.31 | 01-NOV-07:10 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.259236E+10 | 1963.31 | 01-DEC-08:09 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.309943E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.236435E+10 | 1963.31 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.270141E+10 | 1963.31 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.113670E+11 | 10199.01 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.104037E+11 | 10199.01 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.120192E+11 | 10199.01 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.112633E+11 | 10199.01 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.116931E+11 | 10199.01 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.115894E+11 | 10199.01 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.113670E+11 | 10199.01 | 01-JUL-08:09 | 0.00 | 0.00 |
August | 0.120192E+11 | 10199.01 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.112633E+11 | 10199.01 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.113670E+11 | 10199.01 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.109372E+11 | 10199.01 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.113670E+11 | 10199.01 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.136656E+12 | ||||
Minimum of Months | 0.104037E+11 | 10199.01 | 0.00 | 0.00 | |
Maximum of Months | 0.120192E+11 | 10199.01 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.261440E+11 | 23457.71 | 02-JAN-09:09 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.239285E+11 | 23457.71 | 01-FEB-09:09 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.276442E+11 | 23457.71 | 01-MAR-09:09 | 0.956462E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.259056E+11 | 23457.71 | 01-APR-08:09 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.268941E+11 | 23457.71 | 01-MAY-08:09 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.266557E+11 | 23457.71 | 01-JUN-08:09 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.261440E+11 | 23457.71 | 01-JUL-08:09 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.276442E+11 | 23457.71 | 01-AUG-08:09 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.259056E+11 | 23457.71 | 01-SEP-08:09 | 0.885613E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.261440E+11 | 23457.71 | 02-OCT-08:09 | 0.885613E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.251555E+11 | 23457.71 | 01-NOV-08:09 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.261440E+11 | 23457.71 | 01-DEC-09:09 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.314310E+12 | 0.107336E+12 | ||||
Minimum of Months | 0.239285E+11 | 23457.71 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.276442E+11 | 23457.71 | 0.956462E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.544079E+09 | 0.259236E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2599013.50 | 0.908737E+09 |
February | 0.500553E+09 | 0.236435E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 898909.32 | 0.981255E+09 |
March | 0.587605E+09 | 0.270141E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17212.33 | 0.122547E+10 |
April | 0.544079E+09 | 0.255271E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3107275.07 | 0.800580E+09 |
May | 0.565842E+09 | 0.264689E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40895.31 | 0.886675E+09 |
June | 0.565842E+09 | 0.260723E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 769035.85 | 0.592516E+09 |
July | 0.544079E+09 | 0.259236E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20384022.08 | 0.377809E+09 |
August | 0.587605E+09 | 0.270141E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20630487.35 | 0.430818E+09 |
September | 0.544079E+09 | 0.255271E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32736166.10 | 0.508669E+09 |
October | 0.544079E+09 | 0.259236E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61842184.82 | 0.569209E+09 |
November | 0.522316E+09 | 0.249819E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1311876.20 | 0.890053E+09 |
December | 0.544079E+09 | 0.259236E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3283202.28 | 0.885352E+09 |
Annual Sum or Average | 0.659424E+10 | 0.309943E+11 | 0.319458E+11 | 0.147620E+09 | 0.905715E+10 | ||||
Minimum of Months | 0.500553E+09 | 0.236435E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17212.33 | 0.377809E+09 |
Maximum of Months | 0.587605E+09 | 0.270141E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61842184.82 | 0.122547E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.113670E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20220589.01 | 0.496630E+10 |
February | 0.00 | 0.104037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68614.78 | 0.622015E+10 |
March | 0.00 | 0.120192E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.761840E+10 |
April | 0.00 | 0.112633E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1730766.85 | 0.629080E+10 |
May | 0.00 | 0.116931E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.769484E+10 |
June | 0.00 | 0.115894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.546791E+10 |
July | 0.00 | 0.113670E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7078960.48 | 0.424100E+10 |
August | 0.00 | 0.120192E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4324508.68 | 0.483904E+10 |
September | 0.00 | 0.112633E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96513366.55 | 0.442815E+10 |
October | 0.00 | 0.113670E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243325E+09 | 0.534940E+10 |
November | 0.00 | 0.109372E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11809897.84 | 0.558493E+10 |
December | 0.00 | 0.113670E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10918038.25 | 0.525663E+10 |
Annual Sum or Average | 0.136656E+12 | 0.395989E+09 | 0.679576E+11 | ||||||
Minimum of Months | 0.00 | 0.104037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.424100E+10 |
Maximum of Months | 0.00 | 0.120192E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243325E+09 | 0.769484E+10 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.261440E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.406717E+09 | 0.136165E+11 |
February | 0.00 | 0.239285E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30104775.54 | 0.191317E+11 |
March | 0.00 | 0.276442E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16015627.04 | 0.240144E+11 |
April | 0.00 | 0.259056E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 53033188.81 | 0.215387E+11 |
May | 0.00 | 0.268941E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.277203E+11 |
June | 0.00 | 0.266557E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.226988E+11 |
July | 0.00 | 0.261440E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211846E+11 |
August | 0.00 | 0.276442E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228503E+11 |
September | 0.00 | 0.259056E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47643575.85 | 0.192529E+11 |
October | 0.00 | 0.261440E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.418222E+09 | 0.208451E+11 |
November | 0.00 | 0.251555E+11 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106192E+09 | 0.177843E+11 |
December | 0.00 | 0.261440E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.417822E+09 | 0.153977E+11 |
Annual Sum or Average | 0.314310E+12 | 0.107336E+12 | 0.149575E+10 | 0.246035E+12 | |||||
Minimum of Months | 0.00 | 0.239285E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.136165E+11 |
Maximum of Months | 0.00 | 0.276442E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.418222E+09 | 0.277203E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 659.25 | 02-JAN-08:09 | 1963.31 | 02-JAN-08:09 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 460.09 | 18-JAN-13:00 | 4416.14 | 09-JAN-07:10 |
February | 659.25 | 01-FEB-08:09 | 1963.31 | 01-FEB-08:09 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 394.78 | 01-FEB-12:10 | 3489.48 | 10-FEB-07:05 |
March | 659.25 | 01-MAR-08:09 | 1963.31 | 01-MAR-08:09 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 11-MAR-14:00 | 4132.16 | 30-MAR-06:10 |
April | 659.25 | 01-APR-07:10 | 1963.31 | 01-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 466.43 | 26-APR-11:10 | 3179.17 | 17-APR-16:15 |
May | 659.25 | 01-MAY-07:10 | 1963.31 | 01-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.49 | 03-MAY-12:00 | 2869.43 | 26-MAY-06:03 |
June | 659.25 | 01-JUN-07:10 | 1963.31 | 01-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 210.09 | 29-JUN-11:10 | 2395.33 | 05-JUN-06:03 |
July | 659.25 | 01-JUL-07:10 | 1963.31 | 01-JUL-07:10 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 915.07 | 19-JUL-11:55 | 2038.90 | 17-JUL-06:03 |
August | 659.25 | 01-AUG-07:10 | 1963.31 | 01-AUG-07:10 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 900.43 | 18-AUG-12:00 | 2216.40 | 28-AUG-07:00 |
September | 659.25 | 01-SEP-07:10 | 1963.31 | 01-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2591.82 | 29-SEP-12:00 | 2477.67 | 20-SEP-06:03 |
October | 659.25 | 02-OCT-07:10 | 1963.31 | 02-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2861.41 | 16-OCT-11:10 | 3139.81 | 12-OCT-06:03 |
November | 659.25 | 01-NOV-07:10 | 1963.31 | 01-NOV-07:10 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 76.05 | 19-NOV-13:00 | 3374.77 | 30-NOV-07:05 |
December | 659.25 | 01-DEC-08:09 | 1963.31 | 01-DEC-08:09 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 463.51 | 19-DEC-13:00 | 3835.33 | 22-DEC-07:05 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 659.25 | 1963.31 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 2038.90 | |||||
Maximum of Months | 659.25 | 1963.31 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 2861.41 | 4416.14 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 10199.01 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1805.97 | 15-JAN-10:00 | 8415.94 | 27-JAN-05:00 |
February | 0.00 | 10199.01 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 106.53 | 01-FEB-12:00 | 9421.33 | 25-FEB-16:05 |
March | 0.00 | 10199.01 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 13877.68 | 28-MAR-15:05 |
April | 0.00 | 10199.01 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 286.56 | 02-APR-12:00 | 14134.66 | 17-APR-16:15 |
May | 0.00 | 10199.01 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:03 | 13105.26 | 12-MAY-16:00 |
June | 0.00 | 10199.01 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 8254.40 | 12-JUN-16:00 |
July | 0.00 | 10199.01 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 453.45 | 31-JUL-13:00 | 8115.87 | 20-JUL-17:00 |
August | 0.00 | 10199.01 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 365.31 | 17-AUG-13:55 | 6402.38 | 21-AUG-17:00 |
September | 0.00 | 10199.01 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4615.77 | 29-SEP-15:10 | 7658.14 | 02-SEP-15:10 |
October | 0.00 | 10199.01 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4454.37 | 14-OCT-15:10 | 8707.33 | 23-OCT-15:05 |
November | 0.00 | 10199.01 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 945.27 | 19-NOV-13:00 | 8381.78 | 30-NOV-07:10 |
December | 0.00 | 10199.01 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1188.73 | 25-DEC-12:00 | 8384.41 | 13-DEC-08:00 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 0.00 | 10199.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6402.38 | |||
Maximum of Months | 0.00 | 10199.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4615.77 | 14134.66 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 23457.71 | 02-JAN-09:09 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8272.97 | 15-JAN-10:00 | 23997.06 | 27-JAN-05:00 |
February | 0.00 | 23457.71 | 01-FEB-09:09 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4477.45 | 01-FEB-12:00 | 32501.96 | 25-FEB-13:05 |
March | 0.00 | 23457.71 | 01-MAR-09:09 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1460.70 | 11-MAR-11:00 | 37779.45 | 28-MAR-14:10 |
April | 0.00 | 23457.71 | 01-APR-08:09 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3553.30 | 01-APR-12:00 | 43085.32 | 17-APR-16:00 |
May | 0.00 | 23457.71 | 01-MAY-08:09 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:03 | 41064.69 | 12-MAY-16:00 |
June | 0.00 | 23457.71 | 01-JUN-08:09 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 25077.33 | 12-JUN-16:00 |
July | 0.00 | 23457.71 | 01-JUL-08:09 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 30897.87 | 20-JUL-09:00 |
August | 0.00 | 23457.71 | 01-AUG-08:09 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 22392.59 | 22-AUG-16:00 |
September | 0.00 | 23457.71 | 01-SEP-08:09 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3669.80 | 29-SEP-09:42 | 28690.68 | 02-SEP-15:00 |
October | 0.00 | 23457.71 | 02-OCT-08:09 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16486.86 | 14-OCT-10:00 | 29160.13 | 07-OCT-08:00 |
November | 0.00 | 23457.71 | 01-NOV-08:09 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4770.94 | 19-NOV-13:00 | 23357.43 | 01-NOV-08:00 |
December | 0.00 | 23457.71 | 01-DEC-09:09 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 10658.48 | 18-DEC-11:00 | 28304.19 | 12-DEC-13:05 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 23457.71 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22392.59 | ||||
Maximum of Months | 0.00 | 23457.71 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 16486.86 | 43085.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3635.03 | 21-JAN-15:30 | 659.25 | 1963.31 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.23 |
February | 3670.85 | 03-FEB-15:10 | 659.25 | 1963.31 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.34 |
March | 6401.36 | 23-MAR-17:20 | 0.00 | 917.91 | 1147.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 362.76 |
April | 12140.45 | 26-APR-17:10 | 0.00 | 1376.87 | 1721.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.05 |
May | 14443.86 | 01-MAY-00:03 | 0.00 | 1835.82 | 2295.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.73 |
June | 15439.36 | 26-JUN-00:01 | 0.00 | 3212.69 | 4016.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 16162.74 | 05-JUL-00:01 | 0.00 | 3671.64 | 4590.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 14837.90 | 19-AUG-17:43 | 0.00 | 1376.87 | 1721.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.27 |
September | 14594.32 | 05-SEP-00:02 | 0.00 | 2294.78 | 2868.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 15754.21 | 16-OCT-00:01 | 0.00 | 3212.69 | 4016.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.08 |
November | 3895.08 | 18-NOV-15:30 | 659.25 | 1963.31 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.31 |
December | 3882.20 | 05-DEC-15:30 | 659.25 | 1963.31 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3635.03 | 0.00 | 917.91 | 1147.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16162.74 | 659.25 | 3671.64 | 4590.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 362.76 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7866.85 | 12-JAN-07:10 | 0.00 | 7199.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 762.31 |
February | 6932.21 | 28-FEB-07:10 | 0.00 | 7199.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3084.44 |
March | 10248.68 | 10-MAR-07:10 | 0.00 | 7199.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 301.15 |
April | 45750.46 | 30-APR-14:51 | 0.00 | 10798.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3032.35 |
May | 13184.26 | 03-MAY-13:00 | 0.00 | 10199.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 787.11 |
June | 44744.82 | 25-JUN-14:21 | 0.00 | 8399.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3380.81 |
July | 49152.40 | 04-JUL-16:51 | 0.00 | 10798.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 42868.69 | 20-AUG-15:51 | 0.00 | 8399.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2257.93 |
September | 46163.11 | 03-SEP-12:51 | 0.00 | 10798.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2776.12 |
October | 42415.45 | 15-OCT-13:43 | 0.00 | 3599.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2548.22 | 0.00 |
November | 8790.61 | 29-NOV-07:10 | 0.00 | 7199.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 9968.64 | 23-DEC-07:10 | 0.00 | 7199.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 6932.21 | 0.00 | 3599.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 49152.40 | 0.00 | 10798.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2548.22 | 3380.81 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:05 | 0.00 | 5519.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7477.40 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7673.31 |
April | 0.00 | 01-APR-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11700.17 |
May | 0.00 | 01-MAY-00:03 | 0.00 | 11038.92 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8236.16 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6242.55 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5047.70 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6659.61 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7348.20 |
October | 0.00 | 01-OCT-00:05 | 0.00 | 5519.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11138.57 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 2759.73 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8791.96 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 2759.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 11038.92 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11700.17 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.701630E+11 | 55243.99 | 07-JAN-16:00 | 0.155704E+10 | 33074.93 | 03-JAN-06:10 |
February | 0.634521E+11 | 52506.37 | 03-FEB-15:09 | 0.394420E+09 | 9699.68 | 28-FEB-06:10 |
March | 0.720800E+11 | 52892.90 | 23-MAR-14:39 | 0.676089E+09 | 18417.05 | 30-MAR-05:19 |
April | 0.676226E+11 | 57783.65 | 26-APR-13:09 | 51249781.53 | 10134.82 | 01-APR-05:10 |
May | 0.695417E+11 | 56140.43 | 04-MAY-12:09 | 3202742.17 | 1574.07 | 15-MAY-06:10 |
June | 0.698354E+11 | 59134.11 | 29-JUN-12:30 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.719360E+11 | 64436.98 | 31-JUL-13:30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.761961E+11 | 64898.98 | 17-AUG-14:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.698969E+11 | 66653.57 | 29-SEP-12:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.716328E+11 | 66556.36 | 16-OCT-10:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 0.674829E+11 | 56018.16 | 10-NOV-16:00 | 0.128279E+09 | 6426.21 | 27-NOV-06:10 |
December | 0.703834E+11 | 55911.81 | 19-DEC-16:49 | 0.451792E+09 | 10519.75 | 15-DEC-06:10 |
Annual Sum or Average | 0.840223E+12 | 0.326207E+10 | ||||
Minimum of Months | 0.634521E+11 | 52506.37 | 0.00 | 0.00 | ||
Maximum of Months | 0.761961E+11 | 66653.57 | 0.155704E+10 | 33074.93 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.401034E+11 | 0.121724E+11 | 0.115358E+11 | 0.00 | 0.388244E+10 | 0.00 | 0.00 | 0.290402E+09 | 0.00 | 0.00 | 0.00 | 0.217861E+10 | 0.00 |
February | 0.366966E+11 | 0.104046E+11 | 0.105871E+11 | 0.00 | 0.354821E+10 | 0.00 | 0.00 | 0.236155E+09 | 0.00 | 0.00 | 0.00 | 0.197947E+10 | 0.00 |
March | 0.423649E+11 | 0.106638E+11 | 0.123357E+11 | 0.00 | 0.416948E+10 | 0.00 | 0.00 | 0.322088E+09 | 0.00 | 0.00 | 0.00 | 0.222406E+10 | 0.00 |
April | 0.397216E+11 | 0.948055E+10 | 0.114862E+11 | 0.00 | 0.387260E+10 | 0.00 | 0.00 | 0.960790E+09 | 0.00 | 0.00 | 0.00 | 0.210089E+10 | 0.00 |
May | 0.412341E+11 | 0.905154E+10 | 0.119357E+11 | 0.00 | 0.403613E+10 | 0.00 | 0.00 | 0.112860E+10 | 0.00 | 0.00 | 0.00 | 0.215557E+10 | 0.00 |
June | 0.408524E+11 | 0.839153E+10 | 0.118862E+11 | 0.00 | 0.414901E+10 | 0.00 | 0.00 | 0.246763E+10 | 0.00 | 0.00 | 0.00 | 0.208869E+10 | 0.00 |
July | 0.401034E+11 | 0.883468E+10 | 0.115358E+11 | 0.00 | 0.432204E+10 | 0.00 | 0.00 | 0.504033E+10 | 0.00 | 0.00 | 0.00 | 0.209982E+10 | 0.00 |
August | 0.423649E+11 | 0.946169E+10 | 0.123357E+11 | 0.00 | 0.450206E+10 | 0.00 | 0.00 | 0.538198E+10 | 0.00 | 0.00 | 0.00 | 0.214986E+10 | 0.00 |
September | 0.397216E+11 | 0.996141E+10 | 0.114862E+11 | 0.00 | 0.408487E+10 | 0.00 | 0.00 | 0.258201E+10 | 0.00 | 0.00 | 0.00 | 0.206077E+10 | 0.00 |
October | 0.401034E+11 | 0.111636E+11 | 0.115358E+11 | 0.00 | 0.412281E+10 | 0.00 | 0.00 | 0.258279E+10 | 0.00 | 0.00 | 0.00 | 0.212453E+10 | 0.00 |
November | 0.385909E+11 | 0.115643E+11 | 0.110862E+11 | 0.00 | 0.369818E+10 | 0.00 | 0.00 | 0.470040E+09 | 0.00 | 0.00 | 0.00 | 0.207335E+10 | 0.00 |
December | 0.401034E+11 | 0.123799E+11 | 0.115358E+11 | 0.00 | 0.385741E+10 | 0.00 | 0.00 | 0.339913E+09 | 0.00 | 0.00 | 0.00 | 0.216709E+10 | 0.00 |
Annual Sum or Average | 0.481960E+12 | 0.123530E+12 | 0.139282E+12 | 0.482452E+11 | 0.00 | 0.218027E+11 | 0.254027E+11 | ||||||
Minimum of Months | 0.366966E+11 | 0.839153E+10 | 0.105871E+11 | 0.00 | 0.354821E+10 | 0.00 | 0.00 | 0.236155E+09 | 0.00 | 0.00 | 0.00 | 0.197947E+10 | 0.00 |
Maximum of Months | 0.423649E+11 | 0.123799E+11 | 0.123357E+11 | 0.00 | 0.450206E+10 | 0.00 | 0.00 | 0.538198E+10 | 0.00 | 0.00 | 0.00 | 0.222406E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.155704E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.394420E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.676089E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 51249781.53 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 3202742.17 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.128279E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.451792E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.326207E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.155704E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 35620.03 | 02-JAN-09:09 | 7857.24 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 3889.65 | 02-JAN-07:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 35620.03 | 01-FEB-09:09 | 7857.24 | 01-FEB-00:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 3889.65 | 01-FEB-07:10 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 35620.03 | 01-MAR-09:09 | 7857.24 | 01-MAR-00:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 3889.65 | 01-MAR-07:10 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 35620.03 | 01-APR-08:09 | 7857.24 | 01-APR-00:10 | 10112.62 | 01-APR-07:10 | 0.00 | 3889.65 | 08-APR-14:20 | 0.00 | 0.00 | 01-APR-00:10 |
May | 35620.03 | 01-MAY-08:09 | 7857.24 | 01-MAY-00:10 | 10112.62 | 01-MAY-07:10 | 0.00 | 3889.65 | 01-MAY-10:20 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 35620.03 | 01-JUN-08:09 | 7857.24 | 01-JUN-00:10 | 10112.62 | 01-JUN-07:10 | 0.00 | 4465.97 | 27-JUN-12:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 35620.03 | 01-JUL-08:09 | 7857.24 | 01-JUL-00:10 | 10112.62 | 01-JUL-07:10 | 0.00 | 6194.94 | 19-JUL-10:20 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 35620.03 | 01-AUG-08:09 | 7857.24 | 01-AUG-00:10 | 10112.62 | 01-AUG-07:10 | 0.00 | 6194.94 | 14-AUG-10:39 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 35620.03 | 01-SEP-08:09 | 7857.24 | 01-SEP-00:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 6194.94 | 29-SEP-09:50 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 35620.03 | 02-OCT-08:09 | 7857.24 | 01-OCT-00:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 6194.94 | 16-OCT-09:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 35620.03 | 01-NOV-08:09 | 7857.24 | 01-NOV-00:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 3889.65 | 01-NOV-06:10 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 35620.03 | 01-DEC-09:09 | 7857.24 | 01-DEC-00:10 | 10112.62 | 01-DEC-08:09 | 0.00 | 3889.65 | 01-DEC-07:10 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 35620.03 | 7857.24 | 10112.62 | 0.00 | 3889.65 | 0.00 | 0.00 | |||||
Maximum of Months | 35620.03 | 7857.24 | 10112.62 | 0.00 | 6194.94 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 1146.62 | 24-JAN-15:30 | 0.00 | 0.00 | 0.00 | 1805.13 | 26-JAN-12:09 | 0.00 |
February | 1120.50 | 03-FEB-14:00 | 0.00 | 0.00 | 0.00 | 1805.21 | 01-FEB-12:09 | 0.00 |
March | 1568.80 | 23-MAR-15:50 | 0.00 | 0.00 | 0.00 | 1803.22 | 01-MAR-12:39 | 0.00 |
April | 6440.02 | 26-APR-13:09 | 0.00 | 0.00 | 0.00 | 1797.20 | 03-APR-11:00 | 0.00 |
May | 4899.01 | 04-MAY-11:00 | 0.00 | 0.00 | 0.00 | 1789.47 | 01-MAY-11:09 | 0.00 |
June | 7423.32 | 29-JUN-12:00 | 0.00 | 0.00 | 0.00 | 1781.06 | 02-JUN-11:39 | 0.00 |
July | 11358.25 | 31-JUL-14:20 | 0.00 | 0.00 | 0.00 | 1775.13 | 01-JUL-11:09 | 0.00 |
August | 11330.13 | 18-AUG-14:39 | 0.00 | 0.00 | 0.00 | 1774.14 | 31-AUG-11:09 | 0.00 |
September | 12980.44 | 29-SEP-12:00 | 0.00 | 0.00 | 0.00 | 1779.50 | 29-SEP-11:20 | 0.00 |
October | 13460.55 | 16-OCT-11:20 | 0.00 | 0.00 | 0.00 | 1787.80 | 31-OCT-11:09 | 0.00 |
November | 1254.30 | 10-NOV-14:39 | 0.00 | 0.00 | 0.00 | 1795.75 | 29-NOV-12:09 | 0.00 |
December | 1249.56 | 05-DEC-14:00 | 0.00 | 0.00 | 0.00 | 1802.12 | 30-DEC-12:09 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1120.50 | 0.00 | 0.00 | 0.00 | 1774.14 | 0.00 | ||
Maximum of Months | 13460.55 | 0.00 | 0.00 | 0.00 | 1805.21 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 55243.99 | 07-JAN-16:00 | 31660.41 | 10112.62 | 7857.24 | 0.00 | 3889.65 | 0.00 | 0.00 | 116.67 | 0.00 |
February | 52506.37 | 03-FEB-15:09 | 35620.03 | 10112.62 | 0.00 | 0.00 | 3889.65 | 0.00 | 0.00 | 1116.98 | 0.00 |
March | 52892.90 | 23-MAR-14:39 | 35620.03 | 10112.62 | 0.00 | 0.00 | 3889.65 | 0.00 | 0.00 | 1508.87 | 0.00 |
April | 57783.65 | 26-APR-13:09 | 35620.03 | 10112.62 | 0.00 | 0.00 | 3889.65 | 0.00 | 0.00 | 6440.02 | 0.00 |
May | 56140.43 | 04-MAY-12:09 | 35620.03 | 10112.62 | 0.00 | 0.00 | 3889.65 | 0.00 | 0.00 | 4893.15 | 0.00 |
June | 59134.11 | 29-JUN-12:30 | 35620.03 | 10112.62 | 0.00 | 0.00 | 4465.97 | 0.00 | 0.00 | 7193.38 | 0.00 |
July | 64436.98 | 31-JUL-13:30 | 35620.03 | 10112.62 | 0.00 | 0.00 | 6194.94 | 0.00 | 0.00 | 10801.31 | 0.00 |
August | 64898.98 | 17-AUG-14:09 | 35620.03 | 10112.62 | 0.00 | 0.00 | 6194.94 | 0.00 | 0.00 | 11232.05 | 0.00 |
September | 66653.57 | 29-SEP-12:00 | 35620.03 | 10112.62 | 0.00 | 0.00 | 6194.94 | 0.00 | 0.00 | 12980.44 | 0.00 |
October | 66556.36 | 16-OCT-10:00 | 35620.03 | 10112.62 | 0.00 | 0.00 | 6194.94 | 0.00 | 0.00 | 12913.09 | 0.00 |
November | 56018.16 | 10-NOV-16:00 | 31660.41 | 10112.62 | 7857.24 | 0.00 | 3889.65 | 0.00 | 0.00 | 894.13 | 0.00 |
December | 55911.81 | 19-DEC-16:49 | 31660.41 | 10112.62 | 7857.24 | 0.00 | 3889.65 | 0.00 | 0.00 | 785.53 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 52506.37 | 31660.41 | 10112.62 | 0.00 | 0.00 | 3889.65 | 0.00 | 0.00 | 116.67 | 0.00 | |
Maximum of Months | 66653.57 | 35620.03 | 10112.62 | 7857.24 | 0.00 | 6194.94 | 0.00 | 0.00 | 12980.44 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 33074.93 | 03-JAN-06:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 9699.68 | 28-FEB-06:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 18417.05 | 30-MAR-05:19 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 10134.82 | 01-APR-05:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 1574.07 | 15-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 6426.21 | 27-NOV-06:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 10519.75 | 15-DEC-06:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 33074.93 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.17 | 20.26 | 2.17 | 20.26 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.50 | 20.49 | 0.50 | 20.49 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1.33 | 20.40 | 1.33 | 20.40 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.33 | 20.51 | 0.33 | 20.51 | 4.67 | 24.51 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 24.50 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 13.67 | 24.53 | 0.83 | 24.50 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 24.61 | 0.67 | 24.51 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 10.00 | 24.57 | 0.67 | 24.51 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 14.33 | 24.51 | 1.50 | 24.50 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 24.50 | 0.33 | 24.51 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 20.47 | 0.67 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 5.00 | 20.37 | 5.00 | 20.37 | 67.17 | 24.54 | 4.00 | 24.50 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.17 | 20.51 | 2.17 | 20.51 | 14.33 | 24.61 | 1.50 | 24.51 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.00 | 14.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.17 | 14.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.34 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.28 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 27.29 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.28 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.48 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2.17 | 14.97 | 0.00 | 3.83 | 27.37 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.00 | 14.99 | 0.00 | 0.00 | 1.67 | 27.48 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 298.33 | 22.95 | 57.17 | 21.21 | 57.17 | 21.21 |
February | 276.00 | 23.03 | 30.17 | 21.18 | 30.17 | 21.18 |
March | 308.83 | 22.97 | 42.50 | 21.46 | 37.50 | 21.13 |
April | 170.67 | 23.39 | 49.50 | 23.69 | 3.67 | 21.11 |
May | 143.33 | 23.55 | 63.67 | 23.90 | 0.00 | 0.00 |
June | 44.00 | 23.75 | 161.33 | 23.90 | 0.00 | 0.00 |
July | 0.83 | 23.75 | 251.50 | 23.90 | 0.00 | 0.00 |
August | 2.33 | 23.81 | 269.33 | 23.90 | 0.00 | 0.00 |
September | 29.00 | 23.82 | 178.83 | 23.90 | 0.00 | 0.00 |
October | 99.17 | 23.59 | 94.50 | 23.90 | 0.00 | 0.00 |
November | 276.50 | 23.33 | 14.00 | 21.19 | 14.00 | 21.19 |
December | 297.83 | 23.15 | 42.00 | 21.22 | 42.00 | 21.22 |
Annual Sum or Average | 1946.83 | 23.20 | 1254.50 | 23.50 | 184.50 | 21.19 |
Minimum of Months | 0.83 | 22.95 | 14.00 | 21.18 | 0.00 | 0.00 |
Maximum of Months | 308.83 | 23.82 | 269.33 | 23.90 | 57.17 | 21.22 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | ||
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.119806E+10 | 0.290402E+09 | 146.92 | 0.113306E+10 | 65005036.78 | 0.00 | 0.31 | 14-JAN-15:00 | 0.00 | 01-JAN-00:05 | 4778.21 | 24-JAN-15:30 | 4720.03 | 24-JAN-15:30 | 600.09 | 20-JAN-15:30 | 1146.62 | 24-JAN-15:30 | 0.00 | 01-JAN-00:05 |
February | 0.974623E+09 | 0.236155E+09 | 128.17 | 0.919653E+09 | 54969395.44 | 0.00 | 0.33 | 03-FEB-15:00 | 0.00 | 01-FEB-00:10 | 4729.74 | 03-FEB-15:00 | 4729.74 | 03-FEB-15:00 | 528.37 | 11-FEB-15:20 | 1120.50 | 03-FEB-15:00 | 0.00 | 01-FEB-00:10 |
March | 0.133676E+10 | 0.322088E+09 | 154.50 | 0.119148E+10 | 0.145280E+09 | 0.00 | 0.53 | 23-MAR-17:20 | 0.00 | 01-MAR-00:10 | 7963.84 | 23-MAR-17:20 | 7037.06 | 23-MAR-17:20 | 1063.69 | 23-MAR-16:00 | 1952.65 | 23-MAR-17:20 | 0.00 | 01-MAR-00:10 |
April | 0.359712E+10 | 0.857998E+09 | 251.53 | 0.325973E+10 | 0.337385E+09 | 0.00 | 0.87 | 26-APR-17:10 | 0.00 | 01-APR-00:10 | 14987.21 | 26-APR-17:10 | 13513.92 | 26-APR-17:10 | 1473.29 | 26-APR-17:10 | 3293.59 | 26-APR-17:10 | 0.00 | 01-APR-00:10 |
May | 0.432277E+10 | 0.103085E+10 | 289.15 | 0.398678E+10 | 0.335991E+09 | 0.00 | 1.00 | 01-MAY-00:03 | 0.00 | 01-MAY-00:05 | 18149.75 | 01-MAY-00:03 | 15609.72 | 01-MAY-00:03 | 2540.03 | 01-MAY-00:03 | 3822.90 | 01-MAY-00:03 | 0.00 | 01-MAY-00:03 |
June | 0.678762E+10 | 0.160369E+10 | 365.50 | 0.596761E+10 | 0.820009E+09 | 0.00 | 1.00 | 05-JUN-00:03 | 0.00 | 01-JUN-00:10 | 18639.17 | 19-JUN-00:02 | 16331.79 | 24-JUN-17:43 | 3485.09 | 27-JUN-17:10 | 3908.89 | 19-JUN-00:02 | 0.00 | 01-JUN-00:10 |
July | 0.936627E+10 | 0.219912E+10 | 438.43 | 0.790465E+10 | 0.146163E+10 | 0.00 | 1.00 | 01-JUL-17:10 | 0.00 | 01-JUL-00:15 | 19394.50 | 31-JUL-00:01 | 16811.20 | 10-JUL-00:01 | 4929.60 | 31-JUL-00:05 | 4032.95 | 31-JUL-00:01 | 0.00 | 01-JUL-00:10 |
August | 0.980799E+10 | 0.229896E+10 | 448.70 | 0.812069E+10 | 0.168730E+10 | 0.00 | 1.00 | 01-AUG-17:10 | 0.00 | 01-AUG-00:15 | 19643.46 | 07-AUG-00:01 | 16315.22 | 19-AUG-17:43 | 5612.91 | 07-AUG-00:04 | 4071.57 | 07-AUG-00:01 | 0.00 | 01-AUG-00:10 |
September | 0.693968E+10 | 0.166022E+10 | 356.21 | 0.602429E+10 | 0.915398E+09 | 0.00 | 1.00 | 05-SEP-00:02 | 0.00 | 01-SEP-00:10 | 19135.26 | 25-SEP-00:02 | 16445.83 | 29-SEP-17:08 | 4833.46 | 25-SEP-00:02 | 3991.54 | 25-SEP-00:02 | 0.00 | 01-SEP-00:10 |
October | 0.597178E+10 | 0.144739E+10 | 326.63 | 0.544053E+10 | 0.531251E+09 | 0.00 | 1.00 | 02-OCT-00:01 | 0.00 | 01-OCT-00:05 | 19603.78 | 02-OCT-00:01 | 17146.63 | 16-OCT-00:01 | 5213.70 | 02-OCT-00:13 | 4065.49 | 02-OCT-00:01 | 0.00 | 01-OCT-00:05 |
November | 0.194854E+10 | 0.470040E+09 | 195.00 | 0.184713E+10 | 0.101410E+09 | 0.00 | 0.34 | 18-NOV-14:20 | 0.00 | 01-NOV-00:10 | 5320.34 | 10-NOV-14:40 | 5130.40 | 18-NOV-14:30 | 860.44 | 10-NOV-13:20 | 1254.30 | 10-NOV-14:40 | 0.00 | 01-NOV-00:10 |
December | 0.140279E+10 | 0.339913E+09 | 167.33 | 0.136382E+10 | 38970203.76 | 0.00 | 0.35 | 05-DEC-15:00 | 0.00 | 01-DEC-00:10 | 5170.71 | 05-DEC-15:00 | 5170.71 | 05-DEC-15:00 | 553.70 | 07-DEC-15:50 | 1249.56 | 05-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.536540E+11 | 0.127568E+11 | 3268.07 | 0.471594E+11 | 0.649460E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.974623E+09 | 0.236155E+09 | 128.17 | 0.919653E+09 | 38970203.76 | 0.00 | 0.31 | 0.00 | 4729.74 | 4720.03 | 528.37 | 1120.50 | 0.00 | |||||||
Maximum of Months | 0.980799E+10 | 0.229896E+10 | 448.70 | 0.812069E+10 | 0.168730E+10 | 0.00 | 1.00 | 0.00 | 19643.46 | 17146.63 | 5612.91 | 4071.57 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 116.37 | 33.88 | 0.33 | 87.17 | 29.20 | 0.00 | 0.00 | 23-MAR-15:10 | 0.00 | 01-MAR-00:10 | 0.17 | 23-MAR-15:10 | 0.13 | 23-MAR-15:10 | 0.04 | 23-MAR-15:10 | 0.05 | 23-MAR-15:10 | 0.00 | 01-MAR-00:10 |
April | 0.360597E+09 | 0.102792E+09 | 35.58 | 0.304517E+09 | 56079907.17 | 0.00 | 1.00 | 30-APR-11:11 | 0.00 | 01-APR-00:10 | 52171.60 | 30-APR-13:01 | 44981.71 | 30-APR-11:11 | 10989.35 | 30-APR-14:51 | 13192.26 | 30-APR-11:11 | 0.00 | 01-APR-00:10 |
May | 0.341107E+09 | 97746045.51 | 41.50 | 0.283688E+09 | 57419186.16 | 0.00 | 0.26 | 04-MAY-12:00 | 0.00 | 01-MAY-00:03 | 11994.56 | 04-MAY-12:00 | 10299.66 | 03-MAY-13:00 | 2064.77 | 04-MAY-12:30 | 3391.18 | 04-MAY-12:00 | 0.00 | 01-MAY-00:03 |
June | 0.310811E+10 | 0.863937E+09 | 118.77 | 0.218538E+10 | 0.922728E+09 | 0.00 | 1.00 | 18-JUN-11:31 | 0.00 | 01-JUN-00:10 | 55058.67 | 29-JUN-17:11 | 40580.50 | 25-JUN-12:17 | 20663.63 | 29-JUN-17:37 | 13579.87 | 29-JUN-17:11 | 0.00 | 01-JUN-00:10 |
July | 0.104112E+11 | 0.284121E+10 | 209.76 | 0.705879E+10 | 0.335239E+10 | 0.00 | 1.00 | 02-JUL-09:21 | 0.00 | 01-JUL-00:10 | 57126.20 | 31-JUL-17:10 | 42430.16 | 16-JUL-13:11 | 25513.01 | 29-JUL-17:11 | 14155.68 | 23-JUL-10:57 | 0.00 | 01-JUL-00:10 |
August | 0.112775E+11 | 0.308302E+10 | 217.34 | 0.748082E+10 | 0.379673E+10 | 0.00 | 1.00 | 06-AUG-09:41 | 0.00 | 01-AUG-00:10 | 57142.62 | 06-AUG-10:30 | 39996.02 | 19-AUG-17:10 | 25207.38 | 18-AUG-17:11 | 14154.28 | 06-AUG-13:02 | 0.00 | 01-AUG-00:10 |
September | 0.305343E+10 | 0.921793E+09 | 127.29 | 0.256793E+10 | 0.485503E+09 | 0.00 | 1.00 | 03-SEP-12:51 | 0.00 | 01-SEP-00:10 | 54850.44 | 10-SEP-13:30 | 43215.37 | 30-SEP-17:11 | 20056.45 | 10-SEP-12:01 | 13540.69 | 10-SEP-13:30 | 0.00 | 01-SEP-00:10 |
October | 0.369368E+10 | 0.113540E+10 | 116.09 | 0.332882E+10 | 0.364861E+09 | 0.00 | 1.00 | 01-OCT-11:01 | 0.00 | 01-OCT-00:05 | 57387.81 | 01-OCT-11:42 | 46095.92 | 15-OCT-13:43 | 23636.55 | 01-OCT-15:25 | 14320.53 | 01-OCT-12:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.322456E+11 | 0.904589E+10 | 866.67 | 0.232099E+11 | 0.903571E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.112775E+11 | 0.308302E+10 | 217.34 | 0.748082E+10 | 0.379673E+10 | 0.00 | 1.00 | 0.00 | 57387.81 | 46095.92 | 25513.01 | 14320.53 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 61.49 | 31.05 | 30.44 | 75.49 | 105.73 | 0.00 | 0.00 | 744.00 |
February | 73.18 | 33.75 | 39.43 | 85.16 | 97.54 | 0.00 | 0.00 | 672.00 |
March | 83.83 | 37.04 | 46.79 | 99.97 | 101.94 | 0.00 | 0.00 | 744.00 |
April | 115.39 | 59.92 | 55.48 | 153.24 | 92.23 | 0.00 | 0.00 | 720.00 |
May | 113.39 | 52.19 | 61.20 | 142.11 | 87.11 | 0.00 | 0.00 | 744.00 |
June | 120.36 | 60.14 | 60.23 | 161.66 | 69.63 | 0.00 | 0.00 | 720.00 |
July | 127.43 | 68.15 | 59.28 | 182.32 | 63.67 | 0.00 | 0.00 | 744.00 |
August | 119.38 | 64.58 | 54.80 | 174.40 | 66.07 | 0.00 | 0.00 | 744.00 |
September | 102.22 | 54.60 | 47.62 | 143.14 | 75.65 | 0.00 | 0.00 | 720.00 |
October | 78.28 | 42.75 | 35.53 | 113.28 | 83.65 | 0.00 | 0.00 | 744.00 |
November | 70.64 | 36.90 | 33.73 | 86.93 | 104.61 | 0.00 | 0.00 | 720.00 |
December | 62.33 | 33.37 | 28.96 | 77.20 | 110.61 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 94.08 | 47.93 | 46.14 | 124.77 | 88.16 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 61.49 | 31.05 | 28.96 | 75.49 | 63.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 127.43 | 68.15 | 61.20 | 182.32 | 110.61 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 61.49 | 31.05 | 30.44 | 75.49 | 105.73 | 0.00 | 0.00 | 744.00 |
February | 73.18 | 33.75 | 39.43 | 85.16 | 97.54 | 0.00 | 0.00 | 672.00 |
March | 83.83 | 37.04 | 46.79 | 99.97 | 101.94 | 0.00 | 0.00 | 744.00 |
April | 115.39 | 59.92 | 55.48 | 153.24 | 92.23 | 0.00 | 0.00 | 720.00 |
May | 113.39 | 52.19 | 61.20 | 142.11 | 87.11 | 0.00 | 0.00 | 744.00 |
June | 120.36 | 60.14 | 60.23 | 161.66 | 69.63 | 0.00 | 0.00 | 720.00 |
July | 127.43 | 68.15 | 59.28 | 182.32 | 63.67 | 0.00 | 0.00 | 744.00 |
August | 119.38 | 64.58 | 54.80 | 174.40 | 66.07 | 0.00 | 0.00 | 744.00 |
September | 102.22 | 54.60 | 47.62 | 143.14 | 75.65 | 0.00 | 0.00 | 720.00 |
October | 78.28 | 42.75 | 35.53 | 113.28 | 83.65 | 0.00 | 0.00 | 744.00 |
November | 70.64 | 36.90 | 33.73 | 86.93 | 104.61 | 0.00 | 0.00 | 720.00 |
December | 62.33 | 33.37 | 28.96 | 77.20 | 110.61 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 94.08 | 47.93 | 46.14 | 124.77 | 88.16 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 61.49 | 31.05 | 28.96 | 75.49 | 63.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 127.43 | 68.15 | 61.20 | 182.32 | 110.61 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.95 | 0.00 | 13.95 | 7.56 | 64.38 | 0.00 | 0.00 | 744.00 |
February | 17.51 | 0.00 | 17.51 | 8.03 | 59.84 | 0.00 | 0.00 | 672.00 |
March | 21.46 | 0.00 | 21.46 | 12.43 | 62.20 | 0.00 | 0.00 | 744.00 |
April | 24.80 | 0.16 | 24.64 | 15.53 | 56.16 | 0.00 | 0.00 | 720.00 |
May | 29.97 | 1.63 | 28.34 | 17.61 | 50.57 | 0.00 | 0.00 | 744.00 |
June | 31.74 | 3.18 | 28.56 | 22.18 | 39.43 | 0.00 | 0.00 | 720.00 |
July | 30.05 | 2.58 | 27.47 | 23.61 | 36.40 | 0.00 | 0.00 | 744.00 |
August | 25.02 | 0.62 | 24.40 | 21.18 | 39.23 | 0.00 | 0.00 | 744.00 |
September | 21.07 | 0.01 | 21.07 | 16.58 | 46.50 | 0.00 | 0.00 | 720.00 |
October | 16.71 | 0.00 | 16.71 | 15.89 | 50.64 | 0.00 | 0.00 | 744.00 |
November | 15.13 | 0.00 | 15.13 | 7.34 | 64.17 | 0.00 | 0.00 | 720.00 |
December | 12.99 | 0.00 | 12.99 | 6.37 | 67.69 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 21.72 | 0.69 | 21.03 | 14.57 | 53.06 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 12.99 | 0.00 | 12.99 | 6.37 | 36.40 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 31.74 | 3.18 | 28.56 | 23.61 | 67.69 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.95 | 0.00 | 13.95 | 7.56 | 64.38 | 0.00 | 0.00 | 744.00 |
February | 17.51 | 0.00 | 17.51 | 8.03 | 59.84 | 0.00 | 0.00 | 672.00 |
March | 21.46 | 0.00 | 21.46 | 12.43 | 62.20 | 0.00 | 0.00 | 744.00 |
April | 24.80 | 0.16 | 24.64 | 15.53 | 56.16 | 0.00 | 0.00 | 720.00 |
May | 29.97 | 1.63 | 28.34 | 17.61 | 50.57 | 0.00 | 0.00 | 744.00 |
June | 31.73 | 3.18 | 28.56 | 22.18 | 39.43 | 0.00 | 0.00 | 720.00 |
July | 30.05 | 2.58 | 27.47 | 23.61 | 36.40 | 0.00 | 0.00 | 744.00 |
August | 25.02 | 0.62 | 24.40 | 21.18 | 39.23 | 0.00 | 0.00 | 744.00 |
September | 21.07 | 0.01 | 21.06 | 16.58 | 46.50 | 0.00 | 0.00 | 720.00 |
October | 16.71 | 0.00 | 16.71 | 15.89 | 50.64 | 0.00 | 0.00 | 744.00 |
November | 15.13 | 0.00 | 15.13 | 7.34 | 64.17 | 0.00 | 0.00 | 720.00 |
December | 12.99 | 0.00 | 12.99 | 6.37 | 67.69 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 21.72 | 0.69 | 21.03 | 14.57 | 53.06 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 12.99 | 0.00 | 12.99 | 6.37 | 36.40 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 31.73 | 3.18 | 28.56 | 23.61 | 67.69 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 67.71 | 44.70 | 23.01 | 87.92 | 68.69 | 11.83 | 0.00 | 744.00 |
February | 76.98 | 43.35 | 33.64 | 95.35 | 61.34 | 3.00 | 0.00 | 672.00 |
March | 99.48 | 56.25 | 43.22 | 128.32 | 61.52 | 30.00 | 0.00 | 744.00 |
April | 148.54 | 107.20 | 41.34 | 193.66 | 61.74 | 3.33 | 0.00 | 720.00 |
May | 148.22 | 94.35 | 53.87 | 187.88 | 60.33 | 0.00 | 0.00 | 744.00 |
June | 157.19 | 107.27 | 49.92 | 201.28 | 53.32 | 0.00 | 0.00 | 720.00 |
July | 172.24 | 128.19 | 44.06 | 221.51 | 58.74 | 0.00 | 0.00 | 744.00 |
August | 159.64 | 121.67 | 37.97 | 206.06 | 60.74 | 0.00 | 0.00 | 744.00 |
September | 123.14 | 87.12 | 36.02 | 156.80 | 63.07 | 0.50 | 0.00 | 720.00 |
October | 88.47 | 61.05 | 27.43 | 112.33 | 70.72 | 0.00 | 0.00 | 744.00 |
November | 72.13 | 46.29 | 25.84 | 89.98 | 72.23 | 9.33 | 0.00 | 720.00 |
December | 63.18 | 43.07 | 20.10 | 79.51 | 76.37 | 9.50 | 0.00 | 744.00 |
Annual Sum or Average | 114.94 | 78.57 | 36.37 | 146.99 | 64.11 | 67.50 | 0.00 | 8760.00 |
Minimum of Months | 63.18 | 43.07 | 20.10 | 79.51 | 53.32 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 172.24 | 128.19 | 53.87 | 221.51 | 76.37 | 30.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.164704E+09 | 83161027.17 | 81543204.66 | 0.202183E+09 | 0.283197E+09 |
February | 0.177026E+09 | 81641732.75 | 95384754.49 | 0.206008E+09 | 0.235967E+09 |
March | 0.224538E+09 | 99211238.17 | 0.125327E+09 | 0.267771E+09 | 0.273038E+09 |
April | 0.299101E+09 | 0.155309E+09 | 0.143792E+09 | 0.397203E+09 | 0.239068E+09 |
May | 0.303701E+09 | 0.139795E+09 | 0.163907E+09 | 0.380632E+09 | 0.233317E+09 |
June | 0.311985E+09 | 0.155880E+09 | 0.156106E+09 | 0.419032E+09 | 0.180469E+09 |
July | 0.341316E+09 | 0.182529E+09 | 0.158787E+09 | 0.488325E+09 | 0.170534E+09 |
August | 0.319737E+09 | 0.172965E+09 | 0.146773E+09 | 0.467100E+09 | 0.176971E+09 |
September | 0.264966E+09 | 0.141531E+09 | 0.123435E+09 | 0.371026E+09 | 0.196074E+09 |
October | 0.209668E+09 | 0.114507E+09 | 95160416.82 | 0.303418E+09 | 0.224060E+09 |
November | 0.183087E+09 | 95651696.21 | 87435329.09 | 0.225333E+09 | 0.271155E+09 |
December | 0.166939E+09 | 89369873.17 | 77569015.99 | 0.206776E+09 | 0.296265E+09 |
Annual Sum or Average | 0.296677E+10 | 0.151155E+10 | 0.145522E+10 | 0.393481E+10 | 0.278012E+10 |
Minimum of Months | 0.164704E+09 | 81641732.75 | 77569015.99 | 0.202183E+09 | 0.170534E+09 |
Maximum of Months | 0.341316E+09 | 0.182529E+09 | 0.163907E+09 | 0.488325E+09 | 0.296265E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.164704E+09 | 83161027.17 | 81543204.66 | 0.202183E+09 | 0.283197E+09 |
February | 0.177026E+09 | 81641732.75 | 95384754.49 | 0.206008E+09 | 0.235967E+09 |
March | 0.224538E+09 | 99211238.17 | 0.125327E+09 | 0.267771E+09 | 0.273038E+09 |
April | 0.299101E+09 | 0.155309E+09 | 0.143792E+09 | 0.397203E+09 | 0.239068E+09 |
May | 0.303701E+09 | 0.139795E+09 | 0.163907E+09 | 0.380632E+09 | 0.233317E+09 |
June | 0.311985E+09 | 0.155880E+09 | 0.156106E+09 | 0.419032E+09 | 0.180469E+09 |
July | 0.341316E+09 | 0.182529E+09 | 0.158787E+09 | 0.488325E+09 | 0.170534E+09 |
August | 0.319737E+09 | 0.172965E+09 | 0.146773E+09 | 0.467100E+09 | 0.176971E+09 |
September | 0.264966E+09 | 0.141531E+09 | 0.123435E+09 | 0.371026E+09 | 0.196074E+09 |
October | 0.209668E+09 | 0.114507E+09 | 95160416.82 | 0.303418E+09 | 0.224060E+09 |
November | 0.183087E+09 | 95651696.21 | 87435329.09 | 0.225333E+09 | 0.271155E+09 |
December | 0.166939E+09 | 89369873.17 | 77569015.99 | 0.206776E+09 | 0.296265E+09 |
Annual Sum or Average | 0.296677E+10 | 0.151155E+10 | 0.145522E+10 | 0.393481E+10 | 0.278012E+10 |
Minimum of Months | 0.164704E+09 | 81641732.75 | 77569015.99 | 0.202183E+09 | 0.170534E+09 |
Maximum of Months | 0.341316E+09 | 0.182529E+09 | 0.163907E+09 | 0.488325E+09 | 0.296265E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37362038.68 | 0.00 | 37362038.68 | 20247390.08 | 0.172441E+09 |
February | 42360664.79 | 0.00 | 42360664.79 | 19428547.94 | 0.144759E+09 |
March | 57478292.74 | 2044.22 | 57476248.52 | 33292266.12 | 0.166597E+09 |
April | 64282328.51 | 415081.34 | 63867247.17 | 40259743.60 | 0.145563E+09 |
May | 80274667.20 | 4373903.32 | 75900763.88 | 47170558.64 | 0.135445E+09 |
June | 82257438.06 | 8232399.16 | 74025038.89 | 57487337.65 | 0.102190E+09 |
July | 80490241.17 | 6923384.08 | 73566857.09 | 63227510.32 | 97491171.15 |
August | 67021876.97 | 1664277.73 | 65357599.24 | 56741615.91 | 0.105075E+09 |
September | 54622769.71 | 21529.06 | 54601240.65 | 42969993.24 | 0.120535E+09 |
October | 44759735.36 | 0.00 | 44759735.36 | 42571099.06 | 0.135639E+09 |
November | 39219397.29 | 0.00 | 39219397.29 | 19019008.71 | 0.166318E+09 |
December | 34780879.84 | 0.00 | 34780879.84 | 17057000.39 | 0.181304E+09 |
Annual Sum or Average | 0.684910E+09 | 21632618.92 | 0.663278E+09 | 0.459472E+09 | 0.167336E+10 |
Minimum of Months | 34780879.84 | 0.00 | 34780879.84 | 17057000.39 | 97491171.15 |
Maximum of Months | 82257438.06 | 8232399.16 | 75900763.88 | 63227510.32 | 0.181304E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37361001.61 | 0.00 | 37361001.61 | 20246660.17 | 0.172440E+09 |
February | 42359404.44 | 0.00 | 42359404.44 | 19427448.92 | 0.144758E+09 |
March | 57476589.15 | 2044.12 | 57474545.02 | 33290515.76 | 0.166596E+09 |
April | 64280718.47 | 415061.89 | 63865656.59 | 40258436.79 | 0.145562E+09 |
May | 80272338.28 | 4373698.31 | 75898639.97 | 47168331.44 | 0.135445E+09 |
June | 82255047.39 | 8232013.30 | 74023034.09 | 57484737.90 | 0.102190E+09 |
July | 80488119.64 | 6923059.58 | 73565060.07 | 63225496.77 | 97490778.80 |
August | 67020270.40 | 1664199.72 | 65356070.68 | 56740346.48 | 0.105074E+09 |
September | 54621373.68 | 21528.05 | 54599845.62 | 42968673.75 | 0.120534E+09 |
October | 44758538.18 | 0.00 | 44758538.18 | 42570088.07 | 0.135638E+09 |
November | 39218295.25 | 0.00 | 39218295.25 | 19018187.70 | 0.166317E+09 |
December | 34779932.83 | 0.00 | 34779932.83 | 17056566.04 | 0.181303E+09 |
Annual Sum or Average | 0.684892E+09 | 21631604.97 | 0.663260E+09 | 0.459455E+09 | 0.167335E+10 |
Minimum of Months | 34779932.83 | 0.00 | 34779932.83 | 17056566.04 | 97490778.80 |
Maximum of Months | 82255047.39 | 8232013.30 | 75898639.97 | 63225496.77 | 0.181303E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.181347E+09 | 0.119716E+09 | 61630919.77 | 0.235487E+09 | 0.183985E+09 |
February | 0.186236E+09 | 0.104862E+09 | 81373495.60 | 0.230660E+09 | 0.148402E+09 |
March | 0.266443E+09 | 0.150673E+09 | 0.115770E+09 | 0.343686E+09 | 0.164773E+09 |
April | 0.385015E+09 | 0.277859E+09 | 0.107156E+09 | 0.501979E+09 | 0.160040E+09 |
May | 0.396990E+09 | 0.252708E+09 | 0.144282E+09 | 0.503227E+09 | 0.161590E+09 |
June | 0.407430E+09 | 0.278037E+09 | 0.129393E+09 | 0.521730E+09 | 0.138218E+09 |
July | 0.461340E+09 | 0.343333E+09 | 0.118007E+09 | 0.593292E+09 | 0.157337E+09 |
August | 0.427582E+09 | 0.325877E+09 | 0.101705E+09 | 0.551902E+09 | 0.162684E+09 |
September | 0.319172E+09 | 0.225805E+09 | 93367161.82 | 0.406419E+09 | 0.163477E+09 |
October | 0.236966E+09 | 0.163508E+09 | 73458627.40 | 0.300872E+09 | 0.189410E+09 |
November | 0.186967E+09 | 0.119996E+09 | 66971083.52 | 0.233245E+09 | 0.187229E+09 |
December | 0.169211E+09 | 0.115367E+09 | 53844398.11 | 0.212973E+09 | 0.204554E+09 |
Annual Sum or Average | 0.362470E+10 | 0.247774E+10 | 0.114696E+10 | 0.463547E+10 | 0.202170E+10 |
Minimum of Months | 0.169211E+09 | 0.104862E+09 | 53844398.11 | 0.212973E+09 | 0.138218E+09 |
Maximum of Months | 0.461340E+09 | 0.343333E+09 | 0.144282E+09 | 0.593292E+09 | 0.204554E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 161.23 | 335.37 | 150.89 | 62.10 | 88.79 | 0.00 | 0.00 |
February | 181.08 | 309.46 | 181.37 | 67.49 | 113.88 | 0.00 | 0.00 |
March | 219.74 | 323.21 | 210.58 | 74.08 | 136.50 | 0.00 | 0.00 |
April | 333.02 | 292.26 | 280.39 | 120.16 | 160.23 | 0.00 | 0.00 |
May | 317.38 | 273.29 | 286.72 | 107.65 | 179.07 | 0.00 | 0.00 |
June | 366.06 | 216.47 | 304.20 | 126.63 | 177.57 | 0.00 | 0.00 |
July | 410.04 | 198.32 | 314.97 | 141.47 | 173.50 | 0.00 | 0.00 |
August | 388.83 | 208.28 | 288.80 | 130.40 | 158.40 | 0.00 | 0.00 |
September | 314.84 | 239.69 | 246.60 | 109.22 | 137.37 | 0.00 | 0.00 |
October | 254.74 | 264.98 | 189.98 | 85.50 | 104.48 | 0.00 | 0.00 |
November | 182.54 | 331.55 | 171.53 | 73.81 | 97.73 | 0.00 | 0.00 |
December | 161.75 | 351.22 | 150.63 | 66.73 | 83.89 | 0.00 | 0.00 |
Annual Sum or Average | 274.76 | 278.52 | 231.59 | 97.23 | 134.35 | 0.00 | 0.00 |
Minimum of Months | 161.23 | 198.32 | 150.63 | 62.10 | 83.89 | 0.00 | 0.00 |
Maximum of Months | 410.04 | 351.22 | 314.97 | 141.47 | 179.07 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 879.21 | 686.92 | 677.07 | 446.97 | 230.10 | 0.00 | 0.00 |
February | 953.45 | 613.43 | 769.82 | 433.46 | 336.37 | 0.00 | 0.00 |
March | 1283.17 | 615.19 | 994.78 | 562.55 | 432.24 | 0.00 | 0.00 |
April | 1936.65 | 617.44 | 1485.40 | 1071.99 | 413.41 | 0.00 | 0.00 |
May | 1878.84 | 603.31 | 1482.19 | 943.50 | 538.69 | 0.00 | 0.00 |
June | 2012.85 | 533.25 | 1571.88 | 1072.68 | 499.20 | 0.00 | 0.00 |
July | 2215.10 | 587.42 | 1722.45 | 1281.86 | 440.59 | 0.00 | 0.00 |
August | 2060.56 | 607.39 | 1596.41 | 1216.69 | 379.72 | 0.00 | 0.00 |
September | 1567.97 | 630.70 | 1231.38 | 871.16 | 360.21 | 0.00 | 0.00 |
October | 1123.33 | 707.17 | 884.73 | 610.47 | 274.26 | 0.00 | 0.00 |
November | 899.85 | 722.33 | 721.32 | 462.95 | 258.38 | 0.00 | 0.00 |
December | 795.15 | 763.72 | 631.76 | 430.73 | 201.03 | 0.00 | 0.00 |
Annual Sum or Average | 1469.90 | 641.07 | 1149.39 | 785.69 | 363.70 | 0.00 | 0.00 |
Minimum of Months | 795.15 | 533.25 | 631.76 | 430.73 | 201.03 | 0.00 | 0.00 |
Maximum of Months | 2215.10 | 763.72 | 1722.45 | 1281.86 | 538.69 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.431850E+09 | 0.898265E+09 | 0.404132E+09 | 0.166322E+09 | 0.237809E+09 | 0.00 | 0.00 |
February | 0.438058E+09 | 0.748636E+09 | 0.438773E+09 | 0.163283E+09 | 0.275490E+09 | 0.00 | 0.00 |
March | 0.588544E+09 | 0.865687E+09 | 0.564031E+09 | 0.198427E+09 | 0.365604E+09 | 0.00 | 0.00 |
April | 0.863199E+09 | 0.757535E+09 | 0.726765E+09 | 0.311449E+09 | 0.415316E+09 | 0.00 | 0.00 |
May | 0.850060E+09 | 0.731980E+09 | 0.767950E+09 | 0.288337E+09 | 0.479612E+09 | 0.00 | 0.00 |
June | 0.948815E+09 | 0.561098E+09 | 0.788483E+09 | 0.328223E+09 | 0.460259E+09 | 0.00 | 0.00 |
July | 0.109825E+10 | 0.531193E+09 | 0.843611E+09 | 0.378905E+09 | 0.464706E+09 | 0.00 | 0.00 |
August | 0.104145E+10 | 0.557862E+09 | 0.773517E+09 | 0.349258E+09 | 0.424259E+09 | 0.00 | 0.00 |
September | 0.816059E+09 | 0.621286E+09 | 0.639175E+09 | 0.283104E+09 | 0.356071E+09 | 0.00 | 0.00 |
October | 0.682291E+09 | 0.709712E+09 | 0.508854E+09 | 0.229015E+09 | 0.279839E+09 | 0.00 | 0.00 |
November | 0.473140E+09 | 0.859381E+09 | 0.444612E+09 | 0.191303E+09 | 0.253308E+09 | 0.00 | 0.00 |
December | 0.433228E+09 | 0.940700E+09 | 0.403439E+09 | 0.178740E+09 | 0.224699E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.866494E+10 | 0.878333E+10 | 0.730334E+10 | 0.306637E+10 | 0.423697E+10 | 0.00 | 0.00 |
Minimum of Months | 0.431850E+09 | 0.531193E+09 | 0.403439E+09 | 0.163283E+09 | 0.224699E+09 | 0.00 | 0.00 |
Maximum of Months | 0.109825E+10 | 0.940700E+09 | 0.843611E+09 | 0.378905E+09 | 0.479612E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.235487E+10 | 0.183985E+10 | 0.181347E+10 | 0.119716E+10 | 0.616309E+09 | 0.00 | 0.00 |
February | 0.230660E+10 | 0.148401E+10 | 0.186236E+10 | 0.104862E+10 | 0.813735E+09 | 0.00 | 0.00 |
March | 0.343685E+10 | 0.164773E+10 | 0.266443E+10 | 0.150673E+10 | 0.115770E+10 | 0.00 | 0.00 |
April | 0.501979E+10 | 0.160040E+10 | 0.385015E+10 | 0.277859E+10 | 0.107156E+10 | 0.00 | 0.00 |
May | 0.503227E+10 | 0.161590E+10 | 0.396990E+10 | 0.252708E+10 | 0.144282E+10 | 0.00 | 0.00 |
June | 0.521730E+10 | 0.138218E+10 | 0.407430E+10 | 0.278037E+10 | 0.129393E+10 | 0.00 | 0.00 |
July | 0.593291E+10 | 0.157336E+10 | 0.461340E+10 | 0.343333E+10 | 0.118007E+10 | 0.00 | 0.00 |
August | 0.551901E+10 | 0.162684E+10 | 0.427582E+10 | 0.325877E+10 | 0.101705E+10 | 0.00 | 0.00 |
September | 0.406418E+10 | 0.163477E+10 | 0.319172E+10 | 0.225805E+10 | 0.933672E+09 | 0.00 | 0.00 |
October | 0.300872E+10 | 0.189410E+10 | 0.236966E+10 | 0.163508E+10 | 0.734586E+09 | 0.00 | 0.00 |
November | 0.233240E+10 | 0.187228E+10 | 0.186967E+10 | 0.119996E+10 | 0.669711E+09 | 0.00 | 0.00 |
December | 0.212972E+10 | 0.204553E+10 | 0.169211E+10 | 0.115367E+10 | 0.538444E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.463546E+11 | 0.202169E+11 | 0.362470E+11 | 0.247774E+11 | 0.114696E+11 | 0.00 | 0.00 |
Minimum of Months | 0.212972E+10 | 0.138218E+10 | 0.169211E+10 | 0.104862E+10 | 0.538444E+09 | 0.00 | 0.00 |
Maximum of Months | 0.593291E+10 | 0.204553E+10 | 0.461340E+10 | 0.343333E+10 | 0.144282E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 13.22 | 9.60 | 5.99 | 2.23 | 0.81 | 45.19 | 208.20 | 0.00 |
February | 13.28 | 10.19 | 7.03 | 3.12 | 2.95 | 66.07 | 175.60 | 0.04 |
March | 12.64 | 10.60 | 8.97 | 2.93 | 3.55 | 84.90 | 179.28 | 0.03 |
April | 15.30 | 12.61 | 10.61 | 2.62 | 4.75 | 81.20 | 282.81 | 0.02 |
May | 15.56 | 12.64 | 10.56 | 2.92 | 6.16 | 105.80 | 234.18 | 0.01 |
June | 17.67 | 14.80 | 13.02 | 2.53 | 9.02 | 98.05 | 261.27 | 0.00 |
July | 19.43 | 16.75 | 15.28 | 2.35 | 9.62 | 86.54 | 312.15 | 0.00 |
August | 19.66 | 17.23 | 15.95 | 2.55 | 9.61 | 74.58 | 307.55 | 0.00 |
September | 18.47 | 15.49 | 13.65 | 2.19 | 8.98 | 70.75 | 240.05 | 0.00 |
October | 18.77 | 13.71 | 9.60 | 2.71 | 7.73 | 53.88 | 216.36 | 0.00 |
November | 14.32 | 10.42 | 6.22 | 2.47 | 2.40 | 50.75 | 207.87 | 0.01 |
December | 13.59 | 8.80 | 3.19 | 2.50 | 0.04 | 39.49 | 221.83 | 0.00 |
Annual Sum or Average | 16.01 | 12.75 | 10.02 | 2.59 | 5.48 | 71.44 | 237.65 | 0.01 |
Minimum of Months | 12.64 | 8.80 | 3.19 | 2.19 | 0.04 | 39.49 | 175.60 | 0.00 |
Maximum of Months | 19.66 | 17.23 | 15.95 | 3.12 | 9.62 | 105.80 | 312.15 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 26.00 | 13-JAN-13:00 | 15.44 | 8.00 | 3.10 | 11.84 | 120.00 | 725.00 |
February | 26.00 | 01-FEB-11:00 | 14.65 | 6.00 | 4.10 | 10.11 | 166.00 | 715.50 |
March | 24.00 | 11-MAR-10:00 | 13.80 | 6.00 | 2.60 | 8.15 | 120.00 | 907.00 |
April | 27.00 | 26-APR-12:00 | 17.11 | 11.00 | 4.10 | 12.22 | 159.00 | 884.00 |
May | 24.00 | 03-MAY-11:00 | 15.03 | 9.00 | 4.10 | 12.98 | 187.00 | 842.50 |
June | 25.00 | 29-JUN-10:00 | 19.58 | 17.00 | 4.60 | 11.65 | 177.50 | 829.00 |
July | 28.00 | 19-JUL-10:00 | 20.48 | 17.00 | 3.60 | 14.65 | 173.00 | 813.00 |
August | 28.00 | 14-AUG-10:00 | 21.18 | 18.00 | 3.60 | 14.84 | 148.00 | 840.00 |
September | 36.00 | 29-SEP-10:00 | 17.88 | 5.00 | 3.60 | 19.35 | 159.50 | 790.00 |
October | 37.00 | 16-OCT-10:00 | 17.83 | 4.00 | 5.70 | 20.05 | 122.00 | 871.50 |
November | 27.00 | 19-NOV-12:00 | 14.94 | 6.00 | 4.10 | 11.07 | 128.50 | 796.00 |
December | 26.00 | 05-DEC-09:00 | 13.06 | 1.00 | 3.60 | 8.94 | 75.50 | 857.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.00 | 13.06 | 1.00 | 2.60 | 8.15 | 75.50 | 715.50 | |
Maximum of Months | 37.00 | 21.18 | 18.00 | 5.70 | 20.05 | 187.00 | 907.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.00 | 08-JAN-06:00 | -0.2 | -2.0 | 3.10 | -15.5 | 11.50 | 193.50 |
February | 5.00 | 04-FEB-05:00 | 0.20 | -8.0 | 4.10 | -10.9 | 0.00 | 0.00 |
March | 4.00 | 07-MAR-04:00 | 3.53 | 3.00 | 0.00 | -11.4 | 0.00 | 0.00 |
April | 7.00 | 01-APR-05:00 | 4.32 | 1.00 | 4.10 | -9.0 | 23.50 | 211.00 |
May | 8.00 | 14-MAY-03:00 | 7.45 | 7.00 | 1.50 | -6.6 | 0.00 | 0.00 |
June | 11.00 | 13-JUN-03:00 | 9.85 | 9.00 | 2.10 | -3.4 | 0.00 | 0.00 |
July | 13.00 | 06-JUL-00:00 | 13.00 | 13.00 | 0.00 | -0.6 | 0.00 | 0.00 |
August | 14.00 | 24-AUG-01:00 | 14.00 | 14.00 | 0.00 | 0.51 | 0.00 | 0.00 |
September | 11.00 | 20-SEP-02:00 | 9.85 | 9.00 | 1.50 | -3.4 | 0.00 | 0.00 |
October | 9.00 | 12-OCT-04:00 | 6.55 | 4.00 | 3.10 | -6.4 | 0.00 | 0.00 |
November | 7.00 | 05-NOV-01:00 | 5.53 | 4.00 | 3.10 | -8.3 | 0.00 | 0.00 |
December | 5.00 | 03-DEC-00:00 | 5.00 | 5.00 | 2.10 | -0.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.00 | -0.2 | -8.0 | 0.00 | -15.5 | 0.00 | 0.00 | |
Maximum of Months | 14.00 | 14.00 | 14.00 | 4.10 | 0.51 | 23.50 | 211.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 17.02 | 17-JAN-11:00 | 24.00 | 13.00 | 3.10 | 12.79 | 223.50 | 9.00 |
February | 16.80 | 11-FEB-13:00 | 18.00 | 16.20 | 1.10 | 15.02 | 241.00 | 12.50 |
March | 17.40 | 22-MAR-12:00 | 22.00 | 15.00 | 3.10 | 8.35 | 145.50 | 876.00 |
April | 18.31 | 26-APR-10:00 | 26.00 | 14.00 | 4.10 | 12.03 | 141.50 | 915.50 |
May | 16.69 | 05-MAY-14:00 | 18.00 | 16.00 | 5.10 | 8.74 | 303.50 | 269.00 |
June | 19.58 | 29-JUN-10:00 | 25.00 | 17.00 | 4.60 | 11.65 | 177.50 | 829.00 |
July | 21.18 | 19-JUL-11:00 | 28.00 | 18.00 | 4.60 | 14.84 | 182.50 | 808.00 |
August | 21.18 | 18-AUG-11:00 | 28.00 | 18.00 | 3.60 | 17.21 | 244.00 | 667.50 |
September | 21.84 | 22-SEP-11:00 | 26.00 | 20.00 | 2.60 | 20.05 | 284.00 | 21.00 |
October | 21.08 | 01-OCT-11:00 | 26.00 | 19.00 | 3.60 | 13.16 | 102.00 | 899.50 |
November | 16.52 | 10-NOV-12:00 | 21.00 | 14.00 | 5.10 | 7.15 | 131.00 | 808.50 |
December | 15.63 | 07-DEC-12:00 | 20.00 | 13.00 | 5.10 | 5.94 | 89.00 | 868.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.63 | 18.00 | 13.00 | 1.10 | 5.94 | 89.00 | 9.00 | |
Maximum of Months | 21.84 | 28.00 | 20.00 | 5.10 | 20.05 | 303.50 | 915.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 17-JAN-12:00 | 22.00 | 16.84 | 2.10 | 11.65 | 241.50 | 67.50 |
February | 16.20 | 11-FEB-13:00 | 18.00 | 16.80 | 1.10 | 15.02 | 241.00 | 12.50 |
March | 15.00 | 23-MAR-15:20 | 21.67 | 17.33 | 3.77 | 8.01 | 112.00 | 809.83 |
April | 15.00 | 26-APR-21:19 | 16.00 | 15.39 | 2.23 | 6.02 | 0.00 | 0.00 |
May | 16.00 | 05-MAY-14:00 | 18.00 | 16.69 | 5.10 | 8.74 | 303.50 | 269.00 |
June | 17.00 | 28-JUN-08:00 | 19.00 | 17.66 | 1.50 | 16.12 | 285.00 | 428.50 |
July | 18.00 | 18-JUL-10:00 | 26.00 | 20.46 | 4.60 | 12.79 | 169.00 | 819.00 |
August | 18.10 | 14-AUG-09:00 | 26.90 | 20.91 | 3.40 | 13.73 | 139.00 | 817.00 |
September | 20.00 | 22-SEP-09:00 | 22.00 | 20.55 | 1.50 | 16.30 | 296.00 | 18.00 |
October | 19.00 | 01-OCT-07:10 | 19.17 | 19.06 | 0.25 | 16.82 | 53.33 | 0.00 |
November | 15.00 | 10-NOV-17:19 | 16.67 | 15.62 | 2.77 | 3.34 | 0.00 | 0.00 |
December | 13.00 | 07-DEC-12:00 | 20.00 | 15.63 | 5.10 | 5.94 | 89.00 | 868.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 13.00 | 16.00 | 15.39 | 0.25 | 3.34 | 0.00 | 0.00 | |
Maximum of Months | 20.00 | 26.90 | 20.91 | 5.10 | 16.82 | 303.50 | 868.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 17.43 | 27.46 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 17.38 | 30.87 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 17.83 | 38.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 18.69 | 55.75 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 19.73 | 55.13 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 20.65 | 58.21 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 21.22 | 63.49 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 21.28 | 59.02 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 20.81 | 46.26 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 19.94 | 34.64 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 18.91 | 29.25 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 17.99 | 26.27 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.33 | 43.77 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 17.38 | 26.27 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 21.28 | 63.49 | 0.00 |
Report: WaterHeaterReportMonthly
For: ELECTRIC TANK
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.885091E+09 | -742384980.6 | 0.00 | 0.00 | 744.00 | 0.00 | -142706152.7 | 58.99 | 0.00 | 0.00 |
February | 0.810708E+09 | -682812821.3 | 0.00 | 0.00 | 672.00 | 0.00 | -127895123.2 | 58.99 | 0.00 | 0.00 |
March | 0.930372E+09 | -789365402.5 | 0.00 | 0.00 | 744.00 | 0.00 | -141006731.6 | 58.99 | 0.00 | 0.00 |
April | 0.848932E+09 | -718010521.3 | 0.00 | 0.00 | 720.00 | 0.00 | -130921068.8 | 58.99 | 0.00 | 0.00 |
May | 0.861695E+09 | -727618364.7 | 0.00 | 0.00 | 744.00 | 0.00 | -134077081.3 | 58.99 | 0.00 | 0.00 |
June | 0.836896E+09 | -708288248.2 | 0.00 | 0.00 | 720.00 | 0.00 | -128608039.9 | 58.99 | 0.00 | 0.00 |
July | 0.806020E+09 | -674431493.0 | 0.00 | 0.00 | 744.00 | 0.00 | -131588494.3 | 58.99 | 0.00 | 0.00 |
August | 0.855684E+09 | -723274908.1 | 0.00 | 0.00 | 744.00 | 0.00 | -132409399.5 | 58.99 | 0.00 | 0.00 |
September | 0.808799E+09 | -680507967.1 | 0.00 | 0.00 | 720.00 | 0.00 | -128291466.3 | 58.99 | 0.00 | 0.00 |
October | 0.830639E+09 | -697666943.3 | 0.00 | 0.00 | 744.00 | 0.00 | -132972326.2 | 59.00 | 0.00 | 0.00 |
November | 0.821700E+09 | -687604375.8 | 0.00 | 0.00 | 720.00 | 0.00 | -134096120.4 | 58.99 | 0.00 | 0.00 |
December | 0.873361E+09 | -732064268.1 | 0.00 | 0.00 | 744.00 | 0.00 | -141296816.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.101699E+11 | -.856403E+10 | 8760.00 | -.160587E+10 | 58.99 | |||||
Minimum of Months | 0.806020E+09 | -789365402.5 | 0.00 | 0.00 | 672.00 | 0.00 | -142706152.7 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.930372E+09 | -674431493.0 | 0.00 | 0.00 | 744.00 | 0.00 | -127895123.2 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 293.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 279.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 338.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 358.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 393.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 381.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 408.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 390.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 328.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 296.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 300.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 297.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4065.67 | ||||||||||
Minimum of Months | 279.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 408.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.544884E+09 | 25704.83 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.266943E+09 | 25704.83 | 06-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.414116E+09 | 25704.83 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 34457593.11 | 25704.83 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2064739.19 | 1130.34 | 15-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 85437129.50 | 25704.83 | 27-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.307444E+09 | 25704.83 | 13-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.165535E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.544884E+09 | 25704.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.509293E+09 | 60810.81 | 02-JAN-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 45223852.83 | 19919.65 | 30-MAR-04:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.554517E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.509293E+09 | 60810.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATERHEATINGCOIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.119806E+10 | 0.113306E+10 | 4778.21 | 24-JAN-15:30 | 4720.03 | 0.00 |
February | 0.00 | 0.00 | 0.974623E+09 | 0.919653E+09 | 4729.74 | 03-FEB-15:00 | 4729.74 | 0.00 |
March | 0.00 | 0.00 | 0.133676E+10 | 0.119148E+10 | 7963.84 | 23-MAR-17:20 | 7037.06 | 0.00 |
April | 0.00 | 0.00 | 0.359712E+10 | 0.325973E+10 | 14987.21 | 26-APR-17:10 | 13513.92 | 0.00 |
May | 0.00 | 0.00 | 0.432277E+10 | 0.398678E+10 | 18149.75 | 01-MAY-00:03 | 15609.72 | 0.00 |
June | 0.00 | 0.00 | 0.678762E+10 | 0.596761E+10 | 18639.17 | 19-JUN-00:02 | 15595.65 | 0.00 |
July | 0.00 | 0.00 | 0.936627E+10 | 0.790465E+10 | 19394.50 | 31-JUL-00:01 | 15181.09 | 0.00 |
August | 0.00 | 0.00 | 0.980799E+10 | 0.812069E+10 | 19643.46 | 07-AUG-00:01 | 14475.32 | 0.00 |
September | 0.00 | 0.00 | 0.693968E+10 | 0.602429E+10 | 19135.26 | 25-SEP-00:02 | 14301.79 | 0.00 |
October | 0.00 | 0.00 | 0.597178E+10 | 0.544053E+10 | 19603.78 | 02-OCT-00:01 | 15149.03 | 0.00 |
November | 0.00 | 0.00 | 0.194854E+10 | 0.184713E+10 | 5320.34 | 10-NOV-14:40 | 4501.87 | 0.00 |
December | 0.00 | 0.00 | 0.140279E+10 | 0.136382E+10 | 5170.71 | 05-DEC-15:00 | 5170.71 | 0.00 |
Annual Sum or Average | 0.536540E+11 | 0.471594E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.974623E+09 | 0.919653E+09 | 4729.74 | 4501.87 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.980799E+10 | 0.812069E+10 | 19643.46 | 15609.72 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 116.37 | 87.17 | 0.17 | 23-MAR-15:10 | 0.13 | 0.00 |
April | 0.00 | 0.00 | 0.360597E+09 | 0.304517E+09 | 52171.60 | 30-APR-13:01 | 42396.91 | 0.00 |
May | 0.00 | 0.00 | 0.341107E+09 | 0.283688E+09 | 11994.56 | 04-MAY-12:00 | 10035.23 | 0.00 |
June | 0.00 | 0.00 | 0.310811E+10 | 0.218538E+10 | 55058.67 | 29-JUN-17:11 | 35226.12 | 0.00 |
July | 0.00 | 0.00 | 0.104112E+11 | 0.705879E+10 | 57126.20 | 31-JUL-17:10 | 34336.60 | 0.00 |
August | 0.00 | 0.00 | 0.112775E+11 | 0.748082E+10 | 57142.62 | 06-AUG-10:30 | 34571.59 | 0.00 |
September | 0.00 | 0.00 | 0.305343E+10 | 0.256793E+10 | 54850.44 | 10-SEP-13:30 | 35444.93 | 0.00 |
October | 0.00 | 0.00 | 0.369368E+10 | 0.332882E+10 | 57387.81 | 01-OCT-11:42 | 35342.53 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.322456E+11 | 0.232099E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.112775E+11 | 0.748082E+10 | 57387.81 | 42396.91 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATERFAN
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:03 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.119280E+10 | 0.36 | 1193.86 | 02-JAN-08:40 | 0.95 |
February | 0.109288E+10 | 0.37 | 1193.86 | 01-FEB-10:10 | 0.95 |
March | 0.128524E+10 | 0.39 | 1193.86 | 01-MAR-07:30 | 0.95 |
April | 0.119900E+10 | 0.39 | 1193.86 | 01-APR-06:50 | 0.95 |
May | 0.126054E+10 | 0.41 | 1193.86 | 01-MAY-07:10 | 0.95 |
June | 0.132415E+10 | 0.51 | 1193.86 | 01-JUN-07:40 | 0.94 |
July | 0.135519E+10 | 0.59 | 1193.86 | 01-JUL-09:10 | 0.94 |
August | 0.144043E+10 | 0.60 | 1193.86 | 01-AUG-07:30 | 0.94 |
September | 0.127599E+10 | 0.50 | 1193.86 | 01-SEP-08:65 | 0.94 |
October | 0.125038E+10 | 0.45 | 1193.86 | 02-OCT-06:20 | 0.94 |
November | 0.113610E+10 | 0.35 | 1193.86 | 01-NOV-08:20 | 0.95 |
December | 0.118857E+10 | 0.36 | 1193.86 | 01-DEC-08:00 | 0.95 |
Annual Sum or Average | 0.150013E+11 | 0.44 | |||
Minimum of Months | 0.109288E+10 | 0.35 | 1193.86 | 0.94 | |
Maximum of Months | 0.144043E+10 | 0.60 | 1193.86 | 0.95 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.268964E+10 | 0.36 | 2695.79 | 02-JAN-07:10 | 0.91 |
February | 0.245533E+10 | 0.34 | 2695.79 | 01-FEB-07:10 | 0.91 |
March | 0.288424E+10 | 0.37 | 2695.79 | 01-MAR-07:05 | 0.91 |
April | 0.267360E+10 | 0.35 | 2695.79 | 08-APR-14:20 | 0.91 |
May | 0.277559E+10 | 0.35 | 2695.79 | 01-MAY-10:20 | 0.91 |
June | 0.281329E+10 | 0.37 | 2695.79 | 03-JUN-09:50 | 0.91 |
July | 0.286894E+10 | 0.36 | 2695.79 | 01-JUL-09:32 | 0.90 |
August | 0.297464E+10 | 0.37 | 2695.79 | 01-AUG-09:00 | 0.90 |
September | 0.268578E+10 | 0.35 | 2695.79 | 01-SEP-13:50 | 0.91 |
October | 0.270080E+10 | 0.35 | 2695.79 | 02-OCT-13:30 | 0.90 |
November | 0.256208E+10 | 0.33 | 2695.79 | 01-NOV-06:03 | 0.91 |
December | 0.266883E+10 | 0.34 | 2695.79 | 01-DEC-07:03 | 0.91 |
Annual Sum or Average | 0.327528E+11 | 0.35 | |||
Minimum of Months | 0.245533E+10 | 0.33 | 2695.79 | 0.90 | |
Maximum of Months | 0.297464E+10 | 0.37 | 2695.79 | 0.91 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.75 | 3.11 |
February | 0.42 | 1.86 |
March | 0.75 | 2.01 |
April | 1.00 | 5.00 |
May | 0.42 | 5.00 |
June | 0.17 | 5.00 |
July | 0.00 | 0.00 |
August | 0.17 | 0.00 |
September | 0.17 | 0.00 |
October | 0.31 | 3.01 |
November | 1.08 | 4.70 |
December | 0.83 | 2.20 |
Annual Sum or Average | 6.06 | 3.36 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.08 | 5.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.08 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.90 | 0.00 |
July | 4.24 | 0.00 |
August | 2.59 | 0.00 |
September | 0.50 | 0.00 |
October | 0.39 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 8.71 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 4.24 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 3.17 | 0.00 |
August | 1.26 | 0.00 |
September | 0.00 | 0.00 |
October | 0.18 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 4.61 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.17 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.148321E+10 | 0.789687E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.132904E+10 | 0.394420E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.160733E+10 | 0.607193E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.205700E+10 | 51249781.53 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.229139E+10 | 3202742.17 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.292784E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.355432E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.373940E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.293621E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.269777E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.160614E+10 | 0.128279E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.152849E+10 | 0.451792E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.277581E+11 | 0.242582E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.132904E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.373940E+10 | 0.789687E+09 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.268964E+10 | 0.767352E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.245533E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.288424E+10 | 68896170.64 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.277639E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.287333E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.367723E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.571014E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.605766E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.360757E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.383620E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.256208E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.266883E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.417986E+11 | 0.836248E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.245533E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.605766E+10 | 0.767352E+09 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.119280E+10 | 0.119806E+10 | 0.544884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.109288E+10 | 0.974623E+09 | 0.266943E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.128524E+10 | 0.133676E+10 | 0.414116E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.119900E+10 | 0.359712E+10 | 34457593.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.126054E+10 | 0.432277E+10 | 2064739.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.132415E+10 | 0.678762E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.135519E+10 | 0.936627E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.144043E+10 | 0.980799E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.127599E+10 | 0.693968E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.125038E+10 | 0.597178E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.113610E+10 | 0.194854E+10 | 85437129.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.118857E+10 | 0.140279E+10 | 0.307444E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.150013E+11 | 0.536540E+11 | 0.165535E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.109288E+10 | 0.974623E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.144043E+10 | 0.980799E+10 | 0.544884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.268964E+10 | 0.00 | 0.509293E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.245533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.288424E+10 | 116.37 | 45223852.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.267360E+10 | 0.360597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.277559E+10 | 0.341107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.281329E+10 | 0.310811E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.286894E+10 | 0.104112E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.297464E+10 | 0.112775E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.268578E+10 | 0.305343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.270080E+10 | 0.369368E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.256208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.266883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.327528E+11 | 0.322456E+11 | 0.554517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.245533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.297464E+10 | 0.112775E+11 | 0.509293E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.119280E+10 | 0.00 | 0.00 | 0.00 | 0.290402E+09 | 0.00 | 0.789687E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.109288E+10 | 0.00 | 0.00 | 0.00 | 0.236155E+09 | 0.00 | 0.394420E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.128524E+10 | 0.00 | 0.00 | 0.00 | 0.322088E+09 | 0.00 | 0.607193E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.119900E+10 | 0.00 | 0.00 | 0.00 | 0.857998E+09 | 0.00 | 51249781.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.126054E+10 | 0.00 | 0.00 | 0.00 | 0.103085E+10 | 0.00 | 3202742.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.132415E+10 | 0.00 | 0.00 | 0.00 | 0.160369E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.135519E+10 | 0.00 | 0.00 | 0.00 | 0.219912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.144043E+10 | 0.00 | 0.00 | 0.00 | 0.229896E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.127599E+10 | 0.00 | 0.00 | 0.00 | 0.166022E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.125038E+10 | 0.00 | 0.00 | 0.00 | 0.144739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.113610E+10 | 0.00 | 0.00 | 0.00 | 0.470040E+09 | 0.00 | 0.128279E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.118857E+10 | 0.00 | 0.00 | 0.00 | 0.339913E+09 | 0.00 | 0.451792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.150013E+11 | 0.00 | 0.00 | 0.00 | 0.127568E+11 | 0.00 | 0.242582E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.109288E+10 | 0.00 | 0.00 | 0.00 | 0.236155E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.144043E+10 | 0.00 | 0.00 | 0.00 | 0.229896E+10 | 0.00 | 0.789687E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.268964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.767352E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.245533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.288424E+10 | 0.00 | 0.00 | 0.00 | 33.88 | 0.00 | 68896170.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.267360E+10 | 0.00 | 0.00 | 0.00 | 0.102792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.277559E+10 | 0.00 | 0.00 | 0.00 | 97746045.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.281329E+10 | 0.00 | 0.00 | 0.00 | 0.863937E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.286894E+10 | 0.00 | 0.00 | 0.00 | 0.284121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.297464E+10 | 0.00 | 0.00 | 0.00 | 0.308302E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.268578E+10 | 0.00 | 0.00 | 0.00 | 0.921793E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.270080E+10 | 0.00 | 0.00 | 0.00 | 0.113540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.256208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.266883E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.327528E+11 | 0.00 | 0.00 | 0.00 | 0.904589E+10 | 0.00 | 0.836248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.245533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.297464E+10 | 0.00 | 0.00 | 0.00 | 0.308302E+10 | 0.00 | 0.767352E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.364154E+09 | 6453207.86 | 0.00 | 1322709.12 | 0.00 | 0.208177E+09 | 0.335067E+09 | 0.00 | 0.14 |
February | 0.434522E+09 | 2743418.22 | 0.00 | 1221027.08 | 0.00 | 0.108841E+09 | 0.372012E+09 | 0.00 | 0.14 |
March | 0.518168E+09 | 4768525.08 | 0.00 | 1546382.17 | 0.00 | 0.149469E+09 | 0.443401E+09 | 0.00 | 0.15 |
April | 0.146221E+09 | 15597956.31 | 0.00 | 4468176.69 | 0.00 | 21062848.04 | 0.516669E+09 | 0.00 | 0.14 |
May | 0.114826E+09 | 8087537.83 | 0.00 | 6025902.46 | 0.00 | 3744915.23 | 0.577776E+09 | 0.00 | 0.15 |
June | 43721594.53 | 0.122049E+09 | 0.00 | 6933541.07 | 0.00 | 0.00 | 0.296611E+09 | 0.00 | 0.16 |
July | 2051337.46 | 0.490448E+09 | 0.00 | 5439262.07 | 0.00 | 0.00 | 87872423.54 | 0.00 | 0.16 |
August | 6337830.81 | 0.588463E+09 | 0.00 | 4107555.83 | 74846.83 | 0.00 | 76458227.39 | 0.00 | 0.17 |
September | 35590397.08 | 0.225197E+09 | 0.00 | 5936768.36 | 45088.52 | 0.00 | 0.216601E+09 | 0.00 | 0.15 |
October | 90179315.48 | 0.260788E+09 | 0.00 | 4362977.35 | 324702.53 | 0.00 | 0.284263E+09 | 0.00 | 0.15 |
November | 0.218368E+09 | 1579759.36 | 0.00 | 2595036.14 | 0.00 | 69937452.97 | 0.520671E+09 | 0.00 | 0.14 |
December | 0.369425E+09 | 5396266.73 | 0.00 | 1694472.54 | 0.00 | 0.113520E+09 | 0.363211E+09 | 0.00 | 0.14 |
Annual Sum or Average | 0.234356E+10 | 0.173157E+10 | 0.00 | 45653810.89 | 444637.88 | 0.674752E+09 | 0.409061E+10 | 0.00 | 0.15 |
Minimum of Months | 2051337.46 | 1579759.36 | 0.00 | 1221027.08 | 0.00 | 0.00 | 76458227.39 | 0.00 | 0.14 |
Maximum of Months | 0.518168E+09 | 0.588463E+09 | 0.00 | 6933541.07 | 324702.53 | 0.208177E+09 | 0.577776E+09 | 0.00 | 0.17 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.219421E+10 | 0.00 | 0.00 | 0.00 | 42142307.51 | 0.00 | 0.00 | 0.00 | 0.18 |
February | 0.242273E+10 | 0.00 | 0.00 | 0.00 | 9728851.02 | 0.00 | 0.00 | 0.00 | 0.18 |
March | 0.308927E+10 | 0.00 | 0.00 | 74362.58 | 649009.20 | 0.00 | 0.104837E+09 | 0.00 | 0.20 |
April | 0.230870E+10 | 2103575.76 | 0.00 | 2512030.88 | 2265155.75 | 0.00 | 0.173787E+10 | 0.00 | 0.27 |
May | 0.228499E+10 | 2606946.93 | 0.00 | 2974854.96 | 0.00 | 0.00 | 0.231000E+10 | 0.00 | 0.29 |
June | 0.116731E+10 | 12994207.32 | 0.00 | 11723632.12 | 0.00 | 0.00 | 0.441409E+10 | 0.00 | 0.51 |
July | 0.208219E+09 | 0.640777E+09 | 0.00 | 23241888.13 | 0.00 | 0.00 | 0.481665E+10 | 0.00 | 0.68 |
August | 0.358709E+09 | 0.718438E+09 | 0.00 | 20215817.32 | 0.00 | 0.00 | 0.386880E+10 | 0.00 | 0.70 |
September | 0.915548E+09 | 0.214210E+09 | 0.00 | 7332584.29 | 89711.70 | 0.00 | 0.456962E+10 | 0.00 | 0.46 |
October | 0.119761E+10 | 0.496426E+09 | 0.00 | 3059558.81 | 8977606.86 | 0.00 | 0.192919E+10 | 0.00 | 0.34 |
November | 0.252617E+10 | 0.00 | 0.00 | 0.00 | 5738313.04 | 0.00 | 0.00 | 0.00 | 0.18 |
December | 0.210879E+10 | 0.00 | 0.00 | 0.00 | 35587525.50 | 0.00 | 0.00 | 0.00 | 0.18 |
Annual Sum or Average | 0.207823E+11 | 0.208756E+10 | 0.00 | 71134729.07 | 0.105178E+09 | 0.00 | 0.237511E+11 | 0.00 | 0.35 |
Minimum of Months | 0.208219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
Maximum of Months | 0.308927E+10 | 0.718438E+09 | 0.00 | 23241888.13 | 42142307.51 | 0.00 | 0.481665E+10 | 0.00 | 0.70 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:10:41
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |