Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:47
Tabular Output Report in Format: HTML
Building: HotelLarge
Environment: RUNPERIOD 1 ** San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904
Simulation Timestamp: 2020-06-03 19:47:16
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 10362.42 | 913.37 | 913.37 |
Net Site Energy | 10362.42 | 913.37 | 913.37 |
Total Source Energy | 22839.16 | 2013.10 | 2013.10 |
Net Source Energy | 22839.16 | 2013.10 | 2013.10 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 11345.29 |
Net Conditioned Building Area | 11345.29 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 963.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 1005.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 767.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 226.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 1745.02 | 1788.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 982.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 560.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 130.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 90.76 | 2038.30 | 0.00 | 0.00 | 0.00 | 22864.31 |
Refrigeration | 61.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 5571.92 | 4790.50 | 0.00 | 0.00 | 0.00 | 22864.31 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Boiler | 0.00 | 963.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 1005.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 767.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 226.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 959.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 762.04 | 1198.64 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInFreezer | 14.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInRefrigerator | 8.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 590.21 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 32.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 947.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 2.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 560.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 130.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 90.76 | 2038.30 | 0.00 | 0.00 | 0.00 | 18749.60 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4114.71 | |
Refrigeration | General | 7.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LowTempRefrigeration | 20.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MedTempRefrigeration | 34.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 87.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 157.55 | 264.57 | 0.00 | 0.00 | 0.00 | 2.02 |
Other | 245.91 | 157.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 491.12 | 422.25 | 0.00 | 0.00 | 0.00 | 2.02 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 87.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 157.55 | 264.57 | 0.00 | 0.00 | 0.00 | 2.02 |
Other | 245.91 | 157.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 491.12 | 422.25 | 0.00 | 0.00 | 0.00 | 2.02 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 5571.917 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 5571.917 | 100.00 |
Total On-Site and Utility Electric Sources | 5571.917 | 100.00 |
Total Electricity End Uses | 5571.917 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 22864.31 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 22864.31 | 100.00 |
Total Water End Uses | 22864.31 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 3.67 |
Time Setpoint Not Met During Occupied Cooling | 78.83 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 7235.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3C
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CA_SANDIEGO
| Meter |ZoneCoolingSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ZoneHeatingSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ZoneElectricSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |SpaceGainsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | MECH_FLR_1 | STORAGE_FLR_1 | CORRIDOR_FLR_3 | CORRIDOR_FLR_6 |PeakSpaceGainsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | MECH_FLR_1 | STORAGE_FLR_1 | CORRIDOR_FLR_3 | CORRIDOR_FLR_6 |SpaceGainComponentsAtCoolingPeakMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |ComfortReportSimple55Monthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |OccupantComfortDataSummaryMonthly
| BASEMENT PEOPLE | RETAIL_1_FLR_1 PEOPLE | RETAIL_2_FLR_1 PEOPLE | LAUNDRY_FLR_1 PEOPLE | CAFE_FLR_1 PEOPLE | LOBBY_FLR_1 PEOPLE | ROOM_1_FLR_3 PEOPLE | ROOM_2_FLR_3 PEOPLE | ROOM_3_MULT19_FLR_3 PEOPLE | ROOM_4_MULT19_FLR_3 PEOPLE | ROOM_5_FLR_3 PEOPLE | ROOM_6_FLR_3 PEOPLE | ROOM_1_FLR_6 PEOPLE | ROOM_2_FLR_6 PEOPLE | ROOM_3_MULT9_FLR_6 PEOPLE | BANQUET_FLR_6 PEOPLE | DINING_FLR_6 PEOPLE | KITCHEN_FLR_6 PEOPLE |ChillerReportMonthly
| COOLSYS1 CHILLER |BoilerReportMonthly
| HEATSYS1 BOILER |DXReportMonthly
| ROOM_1_FLR_3 FAN COILCOOL COIL | ROOM_2_FLR_3 FAN COILCOOL COIL | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | ROOM_5_FLR_3 FAN COILCOOL COIL | ROOM_6_FLR_3 FAN COILCOOL COIL | ROOM_1_FLR_6 FAN COILCOOL COIL | ROOM_2_FLR_6 FAN COILCOOL COIL | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | VAV WITH REHEAT_COOLC | FLR_3_DOAS_COOLC |WindowReportMonthly
| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |WindowEnergyReportMonthly
| RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | CAFE_FLR_1_WALL_SOUTH_WINDOW | LOBBY_FLR_1_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | ROOM_1_FLR_3_WALL_WEST_WINDOW | ROOM_2_FLR_3_WALL_NORTH_WINDOW | ROOM_2_FLR_3_WALL_WEST_WINDOW | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | ROOM_5_FLR_3_WALL_EAST_WINDOW | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | ROOM_6_FLR_3_WALL_NORTH_WINDOW | ROOM_6_FLR_3_WALL_EAST_WINDOW | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | ROOM_1_FLR_6_WALL_WEST_WINDOW | ROOM_2_FLR_6_WALL_NORTH_WINDOW | ROOM_2_FLR_6_WALL_WEST_WINDOW | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | BANQUET_FLR_6_WALL_NORTH_WINDOW | DINING_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_NORTH_WINDOW | KITCHEN_FLR_6_WALL_EAST_WINDOW | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW |WindowZoneSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |WindowEnergyZoneSummaryMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER | SHW BOOSTER WATER HEATER | SWH LAUNDRY |DaylightingReportMonthly
| LOBBY_FLR_1_DAYLCTRL | CAFE_FLR_1_DAYLCTRL | DINING_FLR_6_DAYLCTRL | BANQUET_FLR_6_DAYLCTRL |CoilReportMonthly
| BASEMENT VAV BOX REHEAT COIL | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | MECH_FLR_1 VAV BOX REHEAT COIL | STORAGE_FLR_1 VAV BOX REHEAT COIL | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | CAFE_FLR_1 VAV BOX REHEAT COIL | LOBBY_FLR_1 VAV BOX REHEAT COIL | ROOM_1_FLR_3 FAN COILHEAT COIL | ROOM_2_FLR_3 FAN COILHEAT COIL | ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | ROOM_5_FLR_3 FAN COILHEAT COIL | ROOM_6_FLR_3 FAN COILHEAT COIL | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | ROOM_1_FLR_6 FAN COILHEAT COIL | ROOM_2_FLR_6 FAN COILHEAT COIL | ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | BANQUET_FLR_6 VAV BOX REHEAT COIL | DINING_FLR_6 VAV BOX REHEAT COIL | KITCHEN_FLR_6 VAV BOX REHEAT COIL | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | VAV WITH REHEAT_HEATC | FLR_3_DOAS_HEATC | ROOM_1_FLR_3 FAN COILCOOL COIL | ROOM_2_FLR_3 FAN COILCOOL COIL | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | ROOM_5_FLR_3 FAN COILCOOL COIL | ROOM_6_FLR_3 FAN COILCOOL COIL | ROOM_1_FLR_6 FAN COILCOOL COIL | ROOM_2_FLR_6 FAN COILCOOL COIL | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | VAV WITH REHEAT_COOLC | FLR_3_DOAS_COOLC |PlantLoopDemandReportMonthly
| SWHSYS1 | HEATSYS1 | COOLSYS1 |FanReportMonthly
| FLR_3_DOAS_FAN | VAV WITH REHEAT_FAN | LAUNDRY_FLR_1 EXHAUST FAN | LOBBY_FLR_1 DUMMY EXHAUST FAN | DINING_FLR_6 DUMMY EXHAUST FAN | BANQUET_FLR_6 DUMMY EXHAUST FAN | KITCHEN_FLR_6 EXHAUST FAN | ROOM_1_FLR_3 FAN COILFAN | ROOM_2_FLR_3 FAN COILFAN | ROOM_3_MULT19_FLR_3 FAN COILFAN | ROOM_4_MULT19_FLR_3 FAN COILFAN | ROOM_5_FLR_3 FAN COILFAN | ROOM_6_FLR_3 FAN COILFAN | ROOM_1_FLR_6 FAN COILFAN | ROOM_2_FLR_6 FAN COILFAN | ROOM_3_MULT9_FLR_6 FAN COILFAN |PumpReportMonthly
| HEATSYS1 PUMP | COOLSYS1 PUMP SECONDARY | SWHSYS1 PUMP | COOLSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 | HEATSYS1 | COOLSYS1 |ZoneTemperatureOscillationReportMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |AirLoopSystemEnergyAndWaterUseMonthly
| VAV WITH REHEAT | FLR_3_DOAS |AirLoopSystemComponentLoadsMonthly
| VAV WITH REHEAT | FLR_3_DOAS |AirLoopSystemComponentEnergyUseMonthly
| VAV WITH REHEAT | FLR_3_DOAS |MechanicalVentilationLoadsMonthly
| BASEMENT | RETAIL_1_FLR_1 | RETAIL_2_FLR_1 | MECH_FLR_1 | STORAGE_FLR_1 | LAUNDRY_FLR_1 | CAFE_FLR_1 | LOBBY_FLR_1 | ROOM_1_FLR_3 | ROOM_2_FLR_3 | ROOM_3_MULT19_FLR_3 | ROOM_4_MULT19_FLR_3 | ROOM_5_FLR_3 | ROOM_6_FLR_3 | CORRIDOR_FLR_3 | ROOM_1_FLR_6 | ROOM_2_FLR_6 | ROOM_3_MULT9_FLR_6 | BANQUET_FLR_6 | DINING_FLR_6 | KITCHEN_FLR_6 | CORRIDOR_FLR_6 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:47 |
RunPeriod | RUNPERIOD 1 |
Weather File | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Latitude [deg] | 32.58 |
Longitude [deg] | -117.0 |
Elevation [m] | 159.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 4559.59 | 1873.43 | 406.47 | 1873.22 | 406.47 |
Above Ground Wall Area [m2] | 4025.82 | 1662.30 | 350.71 | 1662.10 | 350.71 |
Window Opening Area [m2] | 1214.08 | 432.93 | 85.84 | 609.46 | 85.84 |
Gross Window-Wall Ratio [%] | 26.63 | 23.11 | 21.12 | 32.54 | 21.12 |
Above Ground Window-Wall Ratio [%] | 30.16 | 26.04 | 24.48 | 36.67 | 24.48 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 4559.59 | 1873.43 | 406.47 | 1873.22 | 406.47 |
Above Ground Wall Area [m2] | 4025.82 | 1662.30 | 350.71 | 1662.10 | 350.71 |
Window Opening Area [m2] | 1214.08 | 432.93 | 85.84 | 609.46 | 85.84 |
Gross Window-Wall Ratio [%] | 26.63 | 23.11 | 21.12 | 32.54 | 21.12 |
Above Ground Window-Wall Ratio [%] | 30.16 | 26.04 | 24.48 | 36.67 | 24.48 |
Total | |
Gross Roof Area [m2] | 1978.84 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BASEMENT | 1978.83 | Yes | Yes | 4826.41 | 1.00 | 0.00 | 533.77 | 0.00 | 0.00 | 8.4281 | 18.58 | 5.3800 |
RETAIL_1_FLR_1 | 67.07 | Yes | Yes | 265.76 | 1.00 | 68.84 | 0.00 | 23.30 | 23.30 | 12.2063 | 6.19 | 10.7600 |
RETAIL_2_FLR_1 | 77.67 | Yes | Yes | 307.76 | 1.00 | 26.57 | 0.00 | 0.00 | 0.00 | 12.2063 | 6.19 | 10.7600 |
MECH_FLR_1 | 164.24 | Yes | Yes | 650.80 | 1.00 | 62.80 | 0.00 | 0.00 | 0.00 | 9.2031 | 5.3800 | |
STORAGE_FLR_1 | 94.76 | Yes | Yes | 375.47 | 1.00 | 36.23 | 0.00 | 0.00 | 0.00 | 6.1031 | 2.6900 | |
LAUNDRY_FLR_1 | 78.04 | Yes | Yes | 309.22 | 1.00 | 85.75 | 0.00 | 0.00 | 0.00 | 5.8125 | 9.29 | 597.5300 |
CAFE_FLR_1 | 188.86 | Yes | Yes | 748.35 | 1.00 | 152.17 | 0.00 | 65.62 | 65.62 | 10.3656 | 1.33 | 5.3800 |
LOBBY_FLR_1 | 1308.19 | Yes | Yes | 5183.56 | 1.00 | 434.79 | 0.00 | 85.24 | 85.24 | 10.2688 | 3.10 | 8.0700 |
ROOM_1_FLR_3 | 39.02 | Yes | Yes | 118.94 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_2_FLR_3 | 39.02 | Yes | Yes | 118.93 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_3_MULT19_FLR_3 | 24.52 | Yes | Yes | 74.75 | 76.00 | 11.15 | 0.00 | 3.68 | 3.68 | 4.5531 | 16.35 | 10.5200 |
ROOM_4_MULT19_FLR_3 | 24.53 | Yes | Yes | 74.77 | 76.00 | 11.15 | 0.00 | 3.68 | 3.68 | 4.5531 | 16.35 | 10.5200 |
ROOM_5_FLR_3 | 39.02 | Yes | Yes | 118.94 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
ROOM_6_FLR_3 | 39.02 | Yes | Yes | 118.93 | 4.00 | 39.95 | 0.00 | 13.18 | 13.18 | 4.5531 | 26.01 | 6.7500 |
CORRIDOR_FLR_3 | 389.40 | Yes | Yes | 1186.91 | 4.00 | 48.31 | 0.00 | 15.94 | 15.94 | 6.3938 | 0.0000 | |
ROOM_1_FLR_6 | 39.02 | Yes | Yes | 118.94 | 1.00 | 39.95 | 0.00 | 13.19 | 13.19 | 4.5531 | 26.01 | 6.7500 |
ROOM_2_FLR_6 | 39.02 | Yes | Yes | 118.93 | 1.00 | 39.95 | 0.00 | 13.19 | 13.19 | 4.5531 | 26.01 | 6.7500 |
ROOM_3_MULT9_FLR_6 | 24.53 | Yes | Yes | 74.77 | 9.00 | 20.44 | 0.00 | 6.75 | 6.75 | 4.5531 | 16.35 | 10.5200 |
BANQUET_FLR_6 | 331.66 | Yes | Yes | 1010.89 | 1.00 | 97.55 | 0.00 | 32.21 | 32.21 | 10.3656 | 1.33 | 67.8200 |
DINING_FLR_6 | 331.66 | Yes | Yes | 1010.89 | 1.00 | 97.55 | 0.00 | 32.21 | 32.21 | 10.3656 | 1.33 | 67.8200 |
KITCHEN_FLR_6 | 103.30 | Yes | Yes | 314.87 | 1.00 | 87.33 | 0.00 | 26.38 | 26.38 | 11.7219 | 4.65 | 2934.4875 |
CORRIDOR_FLR_6 | 412.12 | Yes | Yes | 1256.16 | 1.00 | 85.47 | 0.00 | 28.22 | 28.22 | 6.3938 | 0.0000 | |
Total | 11345.29 | 35184.81 | 4025.82 | 533.77 | 1214.08 | 1214.08 | 6.8961 | 7.60 | 41.0709 | |||
Conditioned Total | 11345.29 | 35184.81 | 4025.82 | 533.77 | 1214.08 | 1214.08 | 6.8961 | 7.60 | 41.0709 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-SEP-19:10 | 11-JAN-18:40 | - | - | - | 02-JAN-21:10 |
Heating | 0.00 | 140070.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 111233.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 66976.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 14423.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 88772.42 | 104248.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 50891.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 23542.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 6008.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 3660.61 | 174270.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 1831.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 367340.34 | 418589.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | Boiler | 0.00 | 140070.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Cooling | General | 111233.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 66976.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 14423.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 58789.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooking | 29240.64 | 74976.11 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInFreezer | 457.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ReachInRefrigerator | 285.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Laundry | 0.00 | 29272.21 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 1851.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 48888.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 150.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Fans | Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 23542.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 6008.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 3660.61 | 174270.85 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 241.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LowTempRefrigeration | 530.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
MedTempRefrigeration | 1059.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1044.26 | 0.00 | 0.00 | 0.00 |
Cooling | 3183.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 2431.64 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 718.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 5526.49 | 1939.12 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 3112.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1776.12 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 414.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 287.42 | 2209.52 | 0.00 | 0.00 | 0.00 |
Refrigeration | 196.25 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 17646.26 | 5192.90 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 92.04 | 0.00 | 0.00 | 0.00 |
Cooling | 280.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 214.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 63.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 487.12 | 170.92 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 274.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 156.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 36.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.33 | 194.75 | 0.00 | 0.00 | 0.00 |
Refrigeration | 17.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1555.38 | 457.71 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 92.04 | 0.00 | 0.00 | 0.00 |
Cooling | 280.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 214.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 63.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 487.12 | 170.92 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 274.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 156.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 36.50 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.33 | 194.75 | 0.00 | 0.00 | 0.00 |
Refrigeration | 17.30 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1555.38 | 457.71 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
BASEMENT VAV BOX COMPONENT | 2.36 | 0.638401 | 0.588000 | 1.39 | 1.00 | 0.500000 | 0.000597 | 0.000159 | 1.39 | 16.70 | 0.008000 |
RETAIL_1_FLR_1 VAV BOX COMPONENT | 0.293125 | 0.174357 | 0.588000 | 0.172357 | 0.588000 | 0.500000 | 0.002185 | 0.000062 | 0.172357 | 16.70 | 0.008000 |
RETAIL_2_FLR_1 VAV BOX COMPONENT | 0.230233 | 0.257060 | 0.588000 | 0.135377 | 0.685494 | 0.500000 | 0.001482 | 0.000028 | 0.135377 | 16.70 | 0.008000 |
MECH_FLR_1 VAV BOX COMPONENT | 0.211291 | 0.592327 | 0.588000 | 0.124239 | 1.00 | 0.500000 | 0.000643 | 0.000036 | 0.124239 | 16.70 | 0.008000 |
STORAGE_FLR_1 VAV BOX COMPONENT | 0.097769 | 0.738543 | 0.588000 | 0.057488 | 1.00 | 0.500000 | 0.000516 | 0.000020 | 0.057488 | 16.70 | 0.008000 |
LAUNDRY_FLR_1 VAV BOX COMPONENT | 3.31 | 0.071246 | 0.588000 | 1.95 | 0.588000 | 0.500000 | 0.021221 | 0.000252 | 1.95 | 16.70 | 0.008000 |
CAFE_FLR_1 VAV BOX COMPONENT | 1.28 | 0.112725 | 0.588000 | 0.750681 | 0.588000 | 0.500000 | 0.003380 | 0.000197 | 0.750681 | 16.70 | 0.008000 |
LOBBY_FLR_1 VAV BOX COMPONENT | 4.50 | 0.221656 | 0.588000 | 2.64 | 0.591082 | 0.500000 | 0.001719 | 0.000542 | 2.64 | 16.70 | 0.008000 |
CORRIDOR_FLR_3 VAV BOX COMPONENT | 1.19 | 1.00 | 0.588000 | 0.697900 | 1.00 | 0.500000 | 0.000381 | 0.000205 | 0.697900 | 16.70 | 0.008000 |
BANQUET_FLR_6 VAV BOX COMPONENT | 2.08 | 0.121249 | 0.588000 | 1.23 | 0.588000 | 0.500000 | 0.003142 | 0.000224 | 1.23 | 16.70 | 0.008000 |
DINING_FLR_6 VAV BOX COMPONENT | 2.19 | 0.115444 | 0.588000 | 1.29 | 0.588000 | 0.500000 | 0.003300 | 0.000231 | 1.29 | 16.70 | 0.008000 |
KITCHEN_FLR_6 VAV BOX COMPONENT | 2.22 | 0.700000 | 0.588000 | 1.31 | 0.588000 | 0.500000 | 0.010751 | 0.000150 | 1.31 | 16.70 | 0.008000 |
CORRIDOR_FLR_6 VAV BOX COMPONENT | 0.547739 | 0.573337 | 0.588000 | 0.322070 | 1.00 | 0.500000 | 0.000665 | 0.000126 | 0.322070 | 16.70 | 0.008000 |
Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
BASEMENT VAV BOX REHEAT COIL | 7196.63 | 0.000159 | 127.35 |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | 2828.65 | 0.000062 | 55.95 |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | 1273.53 | 0.000028 | 23.62 |
MECH_FLR_1 VAV BOX REHEAT COIL | 1616.73 | 0.000036 | 31.28 |
STORAGE_FLR_1 VAV BOX REHEAT COIL | 924.03 | 0.000020 | 18.24 |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | 11386.89 | 0.000252 | 202.96 |
CAFE_FLR_1 VAV BOX REHEAT COIL | 8909.05 | 0.000197 | 170.03 |
LOBBY_FLR_1 VAV BOX REHEAT COIL | 24520.44 | 0.000542 | 454.08 |
ROOM_1_FLR_3 FAN COILHEAT COIL | 3634.44 | 0.000080 | 82.74 |
ROOM_2_FLR_3 FAN COILHEAT COIL | 3635.01 | 0.000080 | 82.75 |
ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | 21042.69 | 0.000465 | 479.05 |
ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | 21088.33 | 0.000466 | 480.08 |
ROOM_5_FLR_3 FAN COILHEAT COIL | 3633.75 | 0.000080 | 82.72 |
ROOM_6_FLR_3 FAN COILHEAT COIL | 3634.31 | 0.000080 | 82.74 |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | 9299.81 | 0.000205 | 180.48 |
ROOM_1_FLR_6 FAN COILHEAT COIL | 1127.98 | 0.000025 | 25.68 |
ROOM_2_FLR_6 FAN COILHEAT COIL | 1129.93 | 0.000025 | 25.72 |
ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | 5463.03 | 0.000121 | 124.37 |
BANQUET_FLR_6 VAV BOX REHEAT COIL | 10125.81 | 0.000224 | 185.38 |
DINING_FLR_6 VAV BOX REHEAT COIL | 10453.58 | 0.000231 | 191.07 |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | 6768.07 | 0.000150 | 119.76 |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | 5686.14 | 0.000126 | 113.41 |
VAV WITH REHEAT_HEATC | 92205.04 | 0.002037 | 1451.96 |
FLR_3_DOAS_HEATC | 9426.70 | 0.000208 | 148.44 |
Design Size Maximum Air Flow Rate [m3/s] | User-Specified Maximum Air Flow Rate [m3/s] | |
ROOM_1_FLR_3 DIRECT AIR | 0.893239 | 0.061733 |
ROOM_2_FLR_3 DIRECT AIR | 0.872110 | 0.061733 |
ROOM_3_MULT19_FLR_3 DIRECT AIR | 4.88 | 0.836953 |
ROOM_4_MULT19_FLR_3 DIRECT AIR | 5.02 | 0.836953 |
ROOM_5_FLR_3 DIRECT AIR | 0.772598 | 0.061733 |
ROOM_6_FLR_3 DIRECT AIR | 0.764876 | 0.061733 |
ROOM_1_FLR_6 DIRECT AIR | 0.230757 | 0.015433 |
ROOM_2_FLR_6 DIRECT AIR | 0.225325 | 0.015433 |
ROOM_3_MULT9_FLR_6 DIRECT AIR | 0.993524 | 0.099113 |
Design Size Maximum Supply Air Flow Rate [m3/s] | Design Size Maximum Hot Water Flow [m3/s] | Design Size Maximum Cold Water Flow [m3/s] | |
ROOM_1_FLR_3 FAN COIL | 0.893239 | 0.000080 | 0.000349 |
ROOM_2_FLR_3 FAN COIL | 0.872110 | 0.000080 | 0.000341 |
ROOM_3_MULT19_FLR_3 FAN COIL | 4.88 | 0.000465 | 0.001869 |
ROOM_4_MULT19_FLR_3 FAN COIL | 5.02 | 0.000466 | 0.002071 |
ROOM_5_FLR_3 FAN COIL | 0.772598 | 0.000080 | 0.000303 |
ROOM_6_FLR_3 FAN COIL | 0.764876 | 0.000080 | 0.000300 |
ROOM_1_FLR_6 FAN COIL | 0.230757 | 0.000025 | 0.000090 |
ROOM_2_FLR_6 FAN COIL | 0.225325 | 0.000025 | 0.000088 |
ROOM_3_MULT9_FLR_6 FAN COIL | 0.993524 | 0.000121 | 0.000398 |
Design Size Maximum Flow Rate [m3/s] | |
ROOM_1_FLR_3 FAN COILFAN | 0.893239 |
ROOM_2_FLR_3 FAN COILFAN | 0.872110 |
ROOM_3_MULT19_FLR_3 FAN COILFAN | 4.88 |
ROOM_4_MULT19_FLR_3 FAN COILFAN | 5.02 |
ROOM_5_FLR_3 FAN COILFAN | 0.772598 |
ROOM_6_FLR_3 FAN COILFAN | 0.764876 |
ROOM_1_FLR_6 FAN COILFAN | 0.230757 |
ROOM_2_FLR_6 FAN COILFAN | 0.225325 |
ROOM_3_MULT9_FLR_6 FAN COILFAN | 0.993524 |
Design Size Design Water Flow Rate [m3/s] | User-Specified Design Air Flow Rate [m3/s] | Design Size Design Inlet Air Humidity Ratio | Design Size Design Inlet Air Temperature [C] | Design Size Design Inlet Water Temperature [C] | Design Size Design Outlet Air Temperature [C] | Design Size Design Outlet Air Humidity Ratio | Design Size Design Coil Load [W] | Design Size Design Air Flow Rate [m3/s] | |
ROOM_1_FLR_3 FAN COILCOOL COIL | 0.000349 | 0.893239 | 0.008575 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_2_FLR_3 FAN COILCOOL COIL | 0.000341 | 0.872110 | 0.008577 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | 0.001869 | 4.88 | 0.008493 | 21.69 | 6.70 | 12.80 | 0.008493 | ||
ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | 0.002071 | 5.02 | 0.008773 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_5_FLR_3 FAN COILCOOL COIL | 0.000303 | 0.772598 | 0.008587 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_6_FLR_3 FAN COILCOOL COIL | 0.000300 | 0.764876 | 0.008588 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_1_FLR_6 FAN COILCOOL COIL | 0.000090 | 0.230757 | 0.008573 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_2_FLR_6 FAN COILCOOL COIL | 0.000088 | 0.225325 | 0.008575 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | 0.000398 | 0.993524 | 0.008659 | 21.69 | 6.70 | 12.80 | 0.008500 | ||
VAV WITH REHEAT_COOLC | 0.015685 | 0.008783 | 28.38 | 6.70 | 10.94 | 0.008436 | 439146.39 | 20.06 | |
FLR_3_DOAS_COOLC | 0.001712 | 0.008202 | 31.30 | 6.70 | 10.94 | 0.008202 | 47940.88 | 2.05 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
VAV WITH REHEAT | 12.06 | 12.06 | 20.51 | 12.06 | 20.06 | 20.06 | 0.300000 | 0.601085 | 20.06 |
FLR_3_DOAS | 2.05 | 2.05 | 2.05 | 2.05 | 2.05 | 2.05 | 0.300000 | 1.00 | 2.05 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
VAV WITH REHEAT_OA_CONTROLLER | 20.06 | |
FLR_3_DOAS_OA_CONTROLLER | 2.05 | 2.05 |
Design Size Maximum Flow Rate [m3/s] | |
VAV WITH REHEAT_FAN | 20.06 |
Maximum Actuated Flow [m3/s] | Controller Convergence Tolerance | |
VAV WITH REHEAT_COOLC_CONTROLLER | 0.015685 | 0.000030 |
VAV WITH REHEAT_HEATC_CONTROLLER | 0.002037 | |
FLR_3_DOAS_COOLC_CONTROLLER | 0.001712 | 0.000278 |
FLR_3_DOAS_HEATC_CONTROLLER | 0.000208 |
User-Specified Maximum Flow Rate [m3/s] | |
FLR_3_DOAS_FAN | 2.05 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
COOLSYS1 PUMP SECONDARY | 0.023209 | 5558.65 |
HEATSYS1 PUMP | 0.005899 | 1507.19 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SWHSYS1 | 0.000375 | 0.045004 |
HEATSYS1 | 0.005899 | 0.707913 |
COOLSYS1 | 0.023209 | 2.79 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000375 | 47.91 |
COOLSYS1 PUMP | 0.023209 | 1852.88 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000375 |
Design Size Nominal Capacity [W] | User-Specified Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
HEATSYS1 BOILER | 267010.60 | 267010.60 | 0.005899 |
Design Size Reference Chilled Water Flow Rate [m3/s] | Design Size Reference Capacity [W] | User-Specified Reference Capacity [W] | Design Size Reference Condenser Fluid Flow Rate [m3/s] | |
COOLSYS1 CHILLER | 0.023209 | 649777.94 | 650353.95 | 74.14 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesPossible Shadow Receivers | |
RETAIL_1_FLR_1_CEILING | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
CAFE_FLR_1_CEILING | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
LOBBY_FLR_1_CEILING_2 | ROOM_1_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH | ROOM_1_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH | |
Possible Shadow Receivers | |
RETAIL_1_FLR_1_WALL_SOUTH | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | |
RETAIL_2_FLR_1_WALL_WEST | RETAIL_2_FLR_1_WALL_WEST_DOOR | |
STORAGE_FLR_1_WALL_NORTH | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | |
LAUNDRY_FLR_1_WALL_EAST | LAUNDRY_FLR_1_WALL_EAST_DOOR | |
CAFE_FLR_1_WALL_EAST | CAFE_FLR_1_WALL_EAST_DOOR | |
CAFE_FLR_1_WALL_SOUTH | CAFE_FLR_1_WALL_SOUTH_WINDOW | |
LOBBY_FLR_1_WALL_1_NORTH | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | |
LOBBY_FLR_1_WALL_1_SOUTH | LOBBY_FLR_1_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_3_WALL_SOUTH | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_3_WALL_WEST | ROOM_1_FLR_3_WALL_WEST_WINDOW | |
ROOM_2_FLR_3_WALL_NORTH | ROOM_2_FLR_3_WALL_NORTH_WINDOW | |
ROOM_2_FLR_3_WALL_WEST | ROOM_2_FLR_3_WALL_WEST_WINDOW | |
ROOM_3_MULT19_FLR_3_WALL_SOUTH | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_4_MULT19_FLR_3_WALL_NORTH | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | |
ROOM_5_FLR_3_WALL_EAST | ROOM_5_FLR_3_WALL_EAST_WINDOW | |
ROOM_5_FLR_3_WALL_SOUTH | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | |
ROOM_6_FLR_3_WALL_NORTH | ROOM_6_FLR_3_WALL_NORTH_WINDOW | |
ROOM_6_FLR_3_WALL_EAST | ROOM_6_FLR_3_WALL_EAST_WINDOW | |
CORRIDOR_FLR_3_WALL_1_NORTH | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | |
CORRIDOR_FLR_3_WALL_2_NORTH | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | |
CORRIDOR_FLR_3_WALL_1_SOUTH | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | |
CORRIDOR_FLR_3_WALL_2_SOUTH | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | |
ROOM_1_FLR_6_WALL_SOUTH | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | |
ROOM_1_FLR_6_WALL_WEST | ROOM_1_FLR_6_WALL_WEST_WINDOW | |
ROOM_2_FLR_6_WALL_NORTH | ROOM_2_FLR_6_WALL_NORTH_WINDOW | |
ROOM_2_FLR_6_WALL_WEST | ROOM_2_FLR_6_WALL_WEST_WINDOW | |
ROOM_3_MULT9_FLR_6_WALL_SOUTH | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | |
BANQUET_FLR_6_WALL_NORTH | BANQUET_FLR_6_WALL_NORTH_WINDOW | |
DINING_FLR_6_WALL_NORTH | DINING_FLR_6_WALL_NORTH_WINDOW | |
KITCHEN_FLR_6_WALL_NORTH | KITCHEN_FLR_6_WALL_NORTH_WINDOW | |
KITCHEN_FLR_6_WALL_EAST | KITCHEN_FLR_6_WALL_EAST_WINDOW | |
KITCHEN_FLR_6_WALL_1_SOUTH | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | |
CORRIDOR_FLR_6_WALL_1_NORTH | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | |
CORRIDOR_FLR_6_WALL_2_NORTH | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | |
CORRIDOR_FLR_6_WALL_2_SOUTH | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.80 | 14.30 | 13.60 | 13.20 | 13.30 | 12.60 | 15.30 | 15.60 | 17.70 | 19.40 | 19.70 | 18.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 | 32.58 | -116.98 | -8.00 | 159.00 | 99429 | 1.1818 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 16.00 | 7.10 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | HotelLarge | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | DOE-2 |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 22 | 235 | 36 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BASEMENT | 0.0 | 0.00 | 0.00 | 0.00 | 41.45 | 11.51 | -1.22 | 1 | 1 | 1 | 0.00 | 86.56 | 0.00 | 22.86 | -2.44 | 0.00 | 2.44 | 4826.41 | TARP | DOE-2 | 1978.83 | 0.00 | 0.00 | 0.00 | 13 | 0 | 0 | Yes |
2 | RETAIL_1_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 2.90 | 1.98 | 1 | 1 | 1 | 0.00 | 11.58 | 0.00 | 5.79 | 0.00 | 3.96 | 3.96 | 265.76 | TARP | DOE-2 | 67.07 | 68.84 | 45.54 | 23.30 | 6 | 1 | 0 | Yes |
3 | RETAIL_2_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 5.79 | 9.14 | 1.98 | 1 | 1 | 1 | 0.00 | 11.58 | 5.79 | 12.50 | 0.00 | 3.96 | 3.96 | 307.76 | TARP | DOE-2 | 77.67 | 26.57 | 24.62 | 0.00 | 6 | 1 | 0 | Yes |
4 | MECH_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 61.87 | 17.68 | 1.98 | 1 | 1 | 1 | 53.95 | 69.80 | 12.50 | 22.86 | 0.00 | 3.96 | 3.96 | 650.80 | TARP | DOE-2 | 164.24 | 62.80 | 62.80 | 0.00 | 6 | 0 | 0 | Yes |
5 | STORAGE_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 74.37 | 17.68 | 1.98 | 1 | 1 | 1 | 69.80 | 78.94 | 12.50 | 22.86 | 0.00 | 3.96 | 3.96 | 375.47 | TARP | DOE-2 | 94.76 | 36.23 | 28.80 | 0.00 | 6 | 1 | 0 | Yes |
6 | LAUNDRY_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 14.33 | 1.98 | 1 | 1 | 1 | 81.99 | 86.56 | 5.79 | 22.86 | 0.00 | 3.96 | 3.96 | 309.22 | TARP | DOE-2 | 78.04 | 85.75 | 83.80 | 0.00 | 6 | 1 | 0 | Yes |
7 | CAFE_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 70.26 | 2.90 | 1.98 | 1 | 1 | 1 | 53.95 | 86.56 | 0.00 | 5.79 | 0.00 | 3.96 | 3.96 | 748.35 | TARP | DOE-2 | 188.86 | 152.17 | 84.60 | 65.62 | 7 | 2 | 0 | Yes |
8 | LOBBY_FLR_1 | 0.0 | 0.00 | 0.00 | 0.00 | 38.29 | 12.45 | 1.98 | 1 | 1 | 1 | 0.00 | 81.99 | 0.00 | 22.86 | 0.00 | 3.96 | 3.96 | 5183.56 | TARP | DOE-2 | 1308.19 | 434.79 | 345.64 | 85.24 | 18 | 3 | 0 | Yes |
9 | ROOM_1_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 10.06 | 8.53 | 1 | 4 | 1 | 0.00 | 4.57 | 5.79 | 14.33 | 7.01 | 10.06 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
10 | ROOM_2_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 18.59 | 8.53 | 1 | 4 | 1 | 0.00 | 4.57 | 14.33 | 22.86 | 7.01 | 10.06 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
11 | ROOM_3_MULT19_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 8.53 | 9.14 | 8.53 | 1 | 76 | 1 | 6.71 | 10.36 | 5.79 | 12.50 | 7.01 | 10.06 | 3.05 | 74.75 | TARP | DOE-2 | 24.52 | 11.15 | 7.47 | 3.68 | 6 | 1 | 0 | Yes |
12 | ROOM_4_MULT19_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 12.19 | 19.51 | 8.53 | 1 | 76 | 1 | 10.36 | 14.02 | 16.15 | 22.86 | 7.01 | 10.06 | 3.05 | 74.77 | TARP | DOE-2 | 24.53 | 11.15 | 7.47 | 3.68 | 6 | 1 | 0 | Yes |
13 | ROOM_5_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 10.06 | 8.53 | 1 | 4 | 1 | 81.99 | 86.56 | 5.79 | 14.33 | 7.01 | 10.06 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
14 | ROOM_6_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 84.28 | 18.59 | 8.53 | 1 | 4 | 1 | 81.99 | 86.56 | 14.33 | 22.86 | 7.01 | 10.06 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.77 | 13.18 | 6 | 2 | 0 | Yes |
15 | CORRIDOR_FLR_3 | 0.0 | 0.00 | 0.00 | 0.00 | 43.28 | 14.33 | 8.53 | 1 | 4 | 1 | 4.57 | 81.99 | 5.79 | 22.86 | 7.01 | 10.06 | 3.05 | 1186.91 | TARP | DOE-2 | 389.40 | 48.31 | 32.37 | 15.94 | 20 | 4 | 0 | Yes |
16 | ROOM_1_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 10.06 | 17.68 | 1 | 1 | 1 | 0.00 | 4.57 | 5.79 | 14.33 | 16.15 | 19.20 | 3.05 | 118.94 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.19 | 6 | 2 | 0 | Yes |
17 | ROOM_2_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 2.29 | 18.59 | 17.68 | 1 | 1 | 1 | 0.00 | 4.57 | 14.33 | 22.86 | 16.15 | 19.20 | 3.05 | 118.93 | TARP | DOE-2 | 39.02 | 39.95 | 26.76 | 13.19 | 6 | 2 | 0 | Yes |
18 | ROOM_3_MULT9_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 7.93 | 7.62 | 17.68 | 1 | 9 | 1 | 4.57 | 11.28 | 5.79 | 9.45 | 16.15 | 19.20 | 3.05 | 74.77 | TARP | DOE-2 | 24.53 | 20.44 | 13.69 | 6.75 | 6 | 1 | 0 | Yes |
19 | BANQUET_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 26.37 | 17.68 | 17.68 | 1 | 1 | 1 | 10.36 | 42.37 | 12.50 | 22.86 | 16.15 | 19.20 | 3.05 | 1010.89 | TARP | DOE-2 | 331.66 | 97.55 | 65.34 | 32.21 | 6 | 1 | 0 | Yes |
20 | DINING_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 63.55 | 17.68 | 17.68 | 1 | 1 | 1 | 47.55 | 79.55 | 12.50 | 22.86 | 16.15 | 19.20 | 3.05 | 1010.89 | TARP | DOE-2 | 331.66 | 97.55 | 65.34 | 32.21 | 6 | 1 | 0 | Yes |
21 | KITCHEN_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 82.99 | 14.11 | 17.68 | 1 | 1 | 1 | 79.55 | 86.56 | 5.79 | 22.86 | 16.15 | 19.20 | 3.05 | 314.87 | TARP | DOE-2 | 103.30 | 87.33 | 60.95 | 26.38 | 8 | 3 | 0 | Yes |
22 | CORRIDOR_FLR_6 | 0.0 | 0.00 | 0.00 | 0.00 | 41.51 | 13.35 | 17.68 | 1 | 1 | 1 | 4.57 | 81.99 | 5.79 | 22.86 | 16.15 | 19.20 | 3.05 | 1256.16 | TARP | DOE-2 | 412.12 | 85.47 | 57.25 | 28.22 | 15 | 3 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BASEMENT | 1978.83 | 106.5 | 18.581 | 5.382E-002 | 8.428 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 13.808 | No |
2 | RETAIL_1_FLR_1 | 67.07 | 10.8 | 6.194 | 0.161 | 12.206 | 10.760 | 0.000 | 0.000 | 0.000 | 0.000 | 22.966 | No |
3 | RETAIL_2_FLR_1 | 77.67 | 12.5 | 6.194 | 0.161 | 12.206 | 10.760 | 0.000 | 0.000 | 0.000 | 0.000 | 22.966 | No |
4 | MECH_FLR_1 | 164.24 | 0.0 | N/A | 0.000 | 9.203 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 14.583 | No |
5 | STORAGE_FLR_1 | 94.76 | 0.0 | N/A | 0.000 | 6.103 | 2.690 | 0.000 | 0.000 | 0.000 | 0.000 | 8.793 | No |
6 | LAUNDRY_FLR_1 | 78.04 | 8.4 | 9.290 | 0.108 | 5.813 | 61.680 | 535.850 | 0.000 | 0.000 | 0.000 | 603.343 | No |
7 | CAFE_FLR_1 | 188.86 | 142.3 | 1.327 | 0.753 | 10.366 | 5.380 | 0.000 | 0.000 | 0.000 | 0.000 | 15.746 | No |
8 | LOBBY_FLR_1 | 1308.19 | 422.4 | 3.097 | 0.323 | 10.269 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 18.339 | No |
9 | ROOM_1_FLR_3 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
10 | ROOM_2_FLR_3 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
11 | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 16.349 | 6.116E-002 | 4.553 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 15.073 | No |
12 | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 16.354 | 6.115E-002 | 4.553 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 15.073 | No |
13 | ROOM_5_FLR_3 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
14 | ROOM_6_FLR_3 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
15 | CORRIDOR_FLR_3 | 389.40 | 0.0 | N/A | 0.000 | 6.394 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.394 | No |
16 | ROOM_1_FLR_6 | 39.02 | 1.5 | 26.015 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
17 | ROOM_2_FLR_6 | 39.02 | 1.5 | 26.012 | 3.844E-002 | 4.553 | 6.750 | 0.000 | 0.000 | 0.000 | 0.000 | 11.303 | No |
18 | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 16.354 | 6.115E-002 | 4.553 | 10.520 | 0.000 | 0.000 | 0.000 | 0.000 | 15.073 | No |
19 | BANQUET_FLR_6 | 331.66 | 249.9 | 1.327 | 0.753 | 10.366 | 67.820 | 0.000 | 0.000 | 0.000 | 0.000 | 78.186 | No |
20 | DINING_FLR_6 | 331.66 | 249.9 | 1.327 | 0.753 | 10.366 | 67.820 | 0.000 | 0.000 | 0.000 | 0.000 | 78.186 | No |
21 | KITCHEN_FLR_6 | 103.30 | 22.2 | 4.645 | 0.215 | 11.722 | 515.227 | 2419.260 | 0.000 | 0.000 | 0.000 | 2946.209 | No |
22 | CORRIDOR_FLR_6 | 412.12 | 0.0 | N/A | 0.000 | 6.394 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 6.394 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BASEMENT PEOPLE | BLDG_OCC_SCH | BASEMENT | 1978.83 | 106.5 | 106.5 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 106 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | RETAIL_1_FLR_1 PEOPLE | BLDG_OCC_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 10.8 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | RETAIL_2_FLR_1 PEOPLE | BLDG_OCC_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 12.5 | 0.161 | 6.194 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 13 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | LAUNDRY_FLR_1 PEOPLE | BLDG_OCC_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 8.4 | 0.108 | 9.290 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 8 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | CAFE_FLR_1 PEOPLE | BLDG_OCC_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 142.3 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 142 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LOBBY_FLR_1 PEOPLE | BLDG_OCC_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 422.4 | 0.323 | 3.097 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 422 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | ROOM_1_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | ROOM_2_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | ROOM_3_MULT19_FLR_3 PEOPLE | ALWAYS_OFF | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 1.5 | 6.116E-002 | 16.349 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | ROOM_4_MULT19_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 1.5 | 6.115E-002 | 16.354 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
11 | ROOM_5_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
12 | ROOM_6_FLR_3 PEOPLE | GUESTROOM_OCC_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
13 | ROOM_1_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.015 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
14 | ROOM_2_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 1.5 | 3.844E-002 | 26.012 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
15 | ROOM_3_MULT9_FLR_6 PEOPLE | GUESTROOM_OCC_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 1.5 | 6.115E-002 | 16.354 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 2 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
16 | BANQUET_FLR_6 PEOPLE | BLDG_OCC_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 249.9 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 250 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
17 | DINING_FLR_6 PEOPLE | BLDG_OCC_SCH | DINING_FLR_6 | 331.66 | 249.9 | 249.9 | 0.753 | 1.327 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 250 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
18 | KITCHEN_FLR_6 PEOPLE | BLDG_OCC_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 22.2 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BASEMENT_LIGHTS | BLDG_LIGHT_OFFICE_BSMT_SCH | BASEMENT | 1978.83 | 106.5 | 16677.861 | 8.428 | 156.601 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 16677.861 |
2 | RETAIL_1_FLR_1_LIGHTS | BLDG_LIGHT_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 818.691 | 12.206 | 75.602 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 818.691 |
3 | RETAIL_2_FLR_1_LIGHTS | BLDG_LIGHT_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 948.048 | 12.206 | 75.602 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 948.048 |
4 | MECH_FLR_1_LIGHTS | BLDG_LIGHT_MECHANIC_SCH | MECH_FLR_1 | 164.24 | 0.0 | 1511.554 | 9.203 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1511.554 |
5 | STORAGE_FLR_1_LIGHTS | BLDG_LIGHT_STORAGE_SCH | STORAGE_FLR_1 | 94.76 | 0.0 | 578.329 | 6.103 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 578.329 |
6 | LAUNDRY_FLR_1_LIGHTS | BLDG_LIGHT_MISC_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 453.605 | 5.813 | 54.001 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 453.605 |
7 | CAFE_FLR_1_LIGHTS | BLDG_LIGHT_MISC_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 1957.675 | 10.366 | 13.757 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1957.675 |
8 | LOBBY_FLR_1_LIGHTS | BLDG_LIGHT_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 13433.463 | 10.269 | 31.800 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 13433.463 |
9 | ROOM_1_FLR_3_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 177.672 | 4.553 | 118.448 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.672 |
10 | ROOM_2_FLR_3_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 177.652 | 4.553 | 118.434 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.652 |
11 | ROOM_3_MULT19_FLR_3_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 111.660 | 4.553 | 74.440 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 111.660 |
12 | ROOM_4_MULT19_FLR_3_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 111.691 | 4.553 | 74.461 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 111.691 |
13 | ROOM_5_FLR_3_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 177.672 | 4.553 | 118.448 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.672 |
14 | ROOM_6_FLR_3_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 177.652 | 4.553 | 118.434 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.652 |
15 | CORRIDOR_FLR_3_LIGHTS | BLDG_LIGHT_CORRIDOR_SCH | CORRIDOR_FLR_3 | 389.40 | 0.0 | 2489.761 | 6.394 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2489.761 |
16 | ROOM_1_FLR_6_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 177.672 | 4.553 | 118.448 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.672 |
17 | ROOM_2_FLR_6_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 177.652 | 4.553 | 118.434 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 177.652 |
18 | ROOM_3_MULT9_FLR_6_LIGHTS | BLDG_LIGHT_GUESTROOM_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 111.691 | 4.553 | 74.461 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 111.691 |
19 | BANQUET_FLR_6_LIGHTS | BLDG_LIGHT_MISC_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 3437.844 | 10.366 | 13.757 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3437.844 |
20 | DINING_FLR_6_LIGHTS | BLDG_LIGHT_MISC_SCH | DINING_FLR_6 | 331.66 | 249.9 | 3437.844 | 10.366 | 13.757 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3437.844 |
21 | KITCHEN_FLR_6_LIGHTS | BLDG_LIGHT_MISC_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 1210.924 | 11.722 | 54.453 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1210.924 |
22 | CORRIDOR_FLR_6_LIGHTS | BLDG_LIGHT_CORRIDOR_SCH | CORRIDOR_FLR_6 | 412.12 | 0.0 | 2635.028 | 6.394 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2635.028 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BASEMENT_MISCPLUG_EQUIP | BASEMENT_EQUIP_SCH | BASEMENT | 1978.83 | 106.5 | 10646.106 | 5.380 | 99.964 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 10646.106 |
2 | RETAIL_1_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 721.688 | 10.760 | 66.644 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 721.688 |
3 | RETAIL_2_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 835.717 | 10.760 | 66.644 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 835.717 |
4 | MECH_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | MECH_FLR_1 | 164.24 | 0.0 | 883.628 | 5.380 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 883.628 |
5 | STORAGE_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | STORAGE_FLR_1 | 94.76 | 0.0 | 254.902 | 2.690 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 254.902 |
6 | LAUNDRY_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 4813.474 | 61.680 | 573.033 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 4813.474 |
7 | CAFE_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 1016.077 | 5.380 | 7.140 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1016.077 |
8 | LOBBY_FLR_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 10557.062 | 8.070 | 24.991 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 10557.062 |
9 | ROOM_1_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_1_FLR_3 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
10 | ROOM_2_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_2_FLR_3 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
11 | ROOM_3_MULT19_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 257.991 | 10.520 | 171.994 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 257.991 |
12 | ROOM_4_MULT19_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 258.061 | 10.520 | 172.041 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 258.061 |
13 | ROOM_5_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_5_FLR_3 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
14 | ROOM_6_FLR_3_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_6_FLR_3 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
15 | ROOM_1_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_1_FLR_6 | 39.02 | 1.5 | 263.399 | 6.750 | 175.599 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.399 |
16 | ROOM_2_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_2_FLR_6 | 39.02 | 1.5 | 263.368 | 6.750 | 175.579 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 263.368 |
17 | ROOM_3_MULT9_FLR_6_PLUGMISC_EQUIP | GUESTROOM_EQP_SCH_BASE | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 258.061 | 10.520 | 172.041 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 258.061 |
18 | BANQUET_FLR_6_MISCPLUG_EQUIP | KITCHEN_ELEC_EQUIP_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 22493.008 | 67.820 | 90.009 | 0.000 | 0.500 | 0.000 | 0.500 | Cooking | 0.000 | 6747.903 |
19 | DINING_FLR_6_MISCPLUG_EQUIP | KITCHEN_ELEC_EQUIP_SCH | DINING_FLR_6 | 331.66 | 249.9 | 22493.008 | 67.820 | 90.009 | 0.000 | 0.500 | 0.000 | 0.500 | Cooking | 0.000 | 6747.903 |
20 | KITCHEN_FLR_6_MISCELEC_EQUIP | KITCHEN_ELEC_EQUIP_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 52482.799 | 508.040 | 2360.050 | 0.200 | 0.500 | 0.100 | 0.200 | Cooking | 0.000 | 15744.840 |
21 | KITCHEN_FLR_6_REACH-IN-FREEZER | ALWAYS_ON | KITCHEN_FLR_6 | 103.30 | 22.2 | 457.500 | 4.429 | 20.573 | 0.000 | 0.250 | 0.000 | 0.750 | ReachInFreezer | 457.500 | 457.500 |
22 | KITCHEN_FLR_6_REACH-IN-REFRIGERATOR | ALWAYS_ON | KITCHEN_FLR_6 | 103.30 | 22.2 | 285.000 | 2.759 | 12.816 | 0.000 | 0.250 | 0.000 | 0.750 | ReachInRefrigerator | 285.000 | 285.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LAUNDRY_FLR_1_MISCGAS_EQUIP | BLDG_EQUIP_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 41817.449 | 535.850 | 4978.268 | 0.000 | 0.500 | 0.000 | 0.500 | Laundry | 0.000 | 41817.449 |
2 | KITCHEN_FLR_6_MISCGAS_EQUIP | KITCHEN_GAS_EQUIP_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 249920.353 | 2419.260 | 11238.437 | 0.100 | 0.200 | 0.700 | 0.000 | Cooking | 0.000 | 74976.106 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.195 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2284 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.7800 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | NONRES_FLOOR | 24 | 3 | 7 | 0.167 | 0.1963 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
8 | NONRES_FLOOR_CEILING | 27 | 3 | 7 | 0.167 | 0.1963 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
9 | BASEMENT_FLOOR | 30 | 2 | 7 | 0.333 | 2.705 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
10 | BASEMENT_WALL_NORTH_CFACTOR | 33 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | BASEMENT_WALL_EAST_CFACTOR | 34 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | BASEMENT_WALL_SOUTH_CFACTOR | 35 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | BASEMENT_WALL_WEST_CFACTOR | 36 | 2 | 7 | 0.167 | 0.9401 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8365 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.115 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | NONRES_FLOOR_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.833 |
13 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
14 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
15 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
16 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
17 | NONRES_FLOOR_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.833 |
18 | M10 200MM CONCRETE BLOCK BASEMENT WALL | 0.2032 | 1.326 | 1842.000 | 912.000 | 0.1532 |
19 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
20 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 0.9868 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637443 | 3.4637443 | 3.4637443 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.1954460 | 1.1954460 | 1.1954460 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
21 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
22 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
23 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
24 | 9 | -0.41768822E-14 | 0.27520919E-16 | -0.15672466E-09 | 0.83927561E-16 |
25 | 8 | 0.22856702E-07 | 0.10578700E-12 | 0.38803401E-03 | -0.25988854E-09 |
26 | 7 | -0.12546900E-01 | 0.54357740E-08 | -0.23525379E-01 | 0.14266284E-03 |
27 | 6 | 0.41364683 | 0.18861797E-05 | 0.47915075 | -0.48455579E-02 |
28 | 5 | -5.2715232 | 0.70271773E-04 | -4.4954566 | 0.64187715E-01 |
29 | 4 | 33.360936 | 0.57369956E-03 | 21.652120 | -0.42687724 |
30 | 3 | -111.98802 | 0.12481219E-02 | -56.042688 | 1.5262008 |
31 | 2 | 197.88617 | 0.70096321E-03 | 78.258916 | -2.9127067 |
32 | 1 | -171.44340 | 0.74721452E-04 | -55.366563 | 2.7504751 |
33 | 0 | 57.057407 | 0.42462867E-06 | 15.540328 | |
34 | 7 | -0.15963512E-14 | -0.15187529E-16 | -0.22427203E-13 | 0.56155309E-15 |
35 | 6 | 0.17983713E-10 | 0.23594901E-11 | 0.52322926E-09 | -0.18637893E-10 |
36 | 5 | -0.60139213E-07 | 0.11510628E-07 | -0.21924491E-05 | 0.17161312E-06 |
37 | 4 | 0.62746279E-04 | 0.43399923E-05 | 0.17681060E-02 | -0.28244642E-03 |
38 | 3 | -0.90508353E-02 | 0.15320797E-03 | -0.21560640 | 0.43341486E-01 |
39 | 2 | 0.12836503 | 0.66328859E-03 | 2.9007871 | -0.61911613 |
40 | 1 | -0.32478029 | 0.41934727E-03 | -7.1379041 | 1.5697129 |
41 | 0 | 0.20664896 | 0.54311639E-05 | 4.4522013 | |
42 | 7 | -0.22427203E-13 | -0.15187529E-16 | -0.15963512E-14 | 0.56155309E-15 |
43 | 6 | 0.52322926E-09 | 0.23594901E-11 | 0.17983713E-10 | -0.18637893E-10 |
44 | 5 | -0.21924491E-05 | 0.11510628E-07 | -0.60139213E-07 | 0.17161312E-06 |
45 | 4 | 0.17681060E-02 | 0.43399923E-05 | 0.62746279E-04 | -0.28244642E-03 |
46 | 3 | -0.21560640 | 0.15320797E-03 | -0.90508353E-02 | 0.43341486E-01 |
47 | 2 | 2.9007871 | 0.66328859E-03 | 0.12836503 | -0.61911613 |
48 | 1 | -7.1379041 | 0.41934727E-03 | -0.32478029 | 1.5697129 |
49 | 0 | 4.4522013 | 0.54311639E-05 | 0.20664896 | |
50 | 7 | -0.52459208E-15 | -0.63961428E-15 | -0.12292524E-09 | -0.35846135E-17 |
51 | 6 | 0.39860198E-02 | 0.96339020E-07 | 0.40499006E-03 | -0.70890431E-04 |
52 | 5 | -0.20832379 | 0.49172556E-04 | -0.20585669E-01 | 0.38489246E-02 |
53 | 4 | 3.5198270 | 0.18993977E-02 | 0.34924834 | -0.69168259E-01 |
54 | 3 | -23.366787 | 0.13311857E-01 | -2.4329538 | 0.50524779 |
55 | 2 | 64.890127 | 0.19943872E-01 | 7.3672511 | -1.5911358 |
56 | 1 | -76.040094 | 0.56792084E-02 | -9.5568013 | 2.1361271 |
57 | 0 | 31.242244 | 0.96490710E-04 | 4.3344156 | |
58 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
59 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
60 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
61 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
62 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
63 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
64 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
65 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 | |
66 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
67 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
68 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
69 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
70 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
71 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
72 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
73 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 | |
74 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
75 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
76 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
77 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
78 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
79 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
80 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
81 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 | |
82 | 7 | -0.41493644E-09 | 0.26375357E-16 | 0.26213203E-14 | -0.63268016E-17 |
83 | 6 | 0.27465604E-04 | 0.18700671E-07 | 0.31288692E-02 | -0.26247577E-04 |
84 | 5 | -0.19935291E-02 | 0.11146933E-04 | -0.22025565 | 0.19255324E-02 |
85 | 4 | 0.45890804E-01 | 0.50864553E-03 | 4.7717348 | -0.44709298E-01 |
86 | 3 | -0.40280019 | 0.40571884E-02 | -37.694667 | 0.39504237 |
87 | 2 | 1.4296488 | 0.67623010E-02 | 115.84777 | -1.4094303 |
88 | 1 | -2.0629154 | 0.20697549E-02 | -143.53273 | 2.0428830 |
89 | 0 | 1.0055995 | 0.48413807E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 31 | 1 | VerySmooth | 2.615 | 0.252 | 0.162 | 0.251 |
2 | RESWINDOW_U_0.47_SHGC_0.25 | 32 | 1 | VerySmooth | 2.672 | 0.252 | 0.162 | 0.251 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER | SpectralAverage | 2.53892E-002 | 0.16139 | 0.61607 | 0.61607 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12001 | 1.00000 | No | |
2 | RESIDENTIAL WINDOW GLAZING LAYER | SpectralAverage | 2.40629E-002 | 0.16139 | 0.61485 | 0.61485 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.11822 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 7 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CAFE_FLR_1 | 1 | 0 |
2 | LOBBY_FLR_1 | 1 | 0 |
3 | BANQUET_FLR_6 | 1 | 0 |
4 | DINING_FLR_6 | 1 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CAFE_FLR_1 | 0 | |
2 | LOBBY_FLR_1 | 0 | |
3 | BANQUET_FLR_6 | 0 | |
4 | DINING_FLR_6 | 0 |
Number of Refrigeration Compressor Racks | |
1 | 2 |
Compressor Rack Name | # Refrigerated Cases Connected | # WalkIn Coolers Connected | Heat Rejection Location | Condenser Type | COP | |
1 | RACK1 | 1 | 0 | Zone | Air-Cooled | 1.500 |
2 | RACK2 | 1 | 0 | Zone | Air-Cooled | 3.000 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SHW BOOSTER WATER HEATER | 2.2712E-002 | 8000.0 | 1.240 | 1.1473 |
2 | WaterHeater:Mixed | SWH LAUNDRY | 1.1356 | 87921.3 | 0.536 | 0.4981 |
3 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 2.2712 | 175842.6 | 0.000 | 0.0000 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BASEMENT_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
2 | BASEMENT_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
3 | BASEMENT_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
4 | BASEMENT_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
5 | BASEMENT_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
6 | BASEMENT_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
7 | BASEMENT_CEILING_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
8 | BASEMENT_CEILING_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
9 | BASEMENT_CEILING_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
10 | BASEMENT_CEILING_5 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
11 | BASEMENT_CEILING_6 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
12 | BASEMENT_CEILING_7 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
13 | BASEMENT_CEILING_8 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
14 | BASEMENT_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.44 | 0.00 | 36.17 | -999.00 | 0 | No | No |
15 | RETAIL_1_FLR_1_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 4 | No | No |
16 | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 1 | No | No |
17 | RETAIL_1_FLR_1_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 3 | No | No |
18 | RETAIL_1_FLR_1_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
19 | RETAIL_1_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
20 | RETAIL_1_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
21 | RETAIL_1_FLR_1_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
22 | RETAIL_1_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 17.37 | 7.72 | 0.34 | 0 | No | No |
23 | RETAIL_2_FLR_1_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
24 | RETAIL_2_FLR_1_WALL_WEST_DOOR | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
25 | RETAIL_2_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
26 | RETAIL_2_FLR_1_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
27 | RETAIL_2_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
28 | RETAIL_2_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
29 | RETAIL_2_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
30 | RETAIL_2_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 6.71 | 8.49 | 0.00 | 0 | No | No |
31 | MECH_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
32 | MECH_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
33 | MECH_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
34 | MECH_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
35 | MECH_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
36 | MECH_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
37 | MECH_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 15.85 | 12.53 | 0.00 | 0 | No | No |
38 | STORAGE_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
39 | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
40 | STORAGE_FLR_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
41 | STORAGE_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
42 | STORAGE_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
43 | STORAGE_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
44 | STORAGE_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
45 | STORAGE_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 9.14 | 9.72 | 0.00 | 0 | No | No |
46 | LAUNDRY_FLR_1_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
47 | LAUNDRY_FLR_1_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
48 | LAUNDRY_FLR_1_WALL_EAST_DOOR | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
49 | LAUNDRY_FLR_1_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
50 | LAUNDRY_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
51 | LAUNDRY_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
52 | LAUNDRY_FLR_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
53 | LAUNDRY_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 21.64 | 7.21 | 0.00 | 0 | No | No |
54 | CAFE_FLR_1_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 3 | No | No |
55 | CAFE_FLR_1_WALL_EAST_DOOR | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
56 | CAFE_FLR_1_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 4 | No | No |
57 | CAFE_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 1 | No | No |
58 | CAFE_FLR_1_WALL_1_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
59 | CAFE_FLR_1_WALL_2_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
60 | CAFE_FLR_1_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
61 | CAFE_FLR_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
62 | CAFE_FLR_1_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
63 | CAFE_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 38.40 | 9.84 | 0.43 | 0 | No | No |
64 | LOBBY_FLR_1_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 3 | No | No |
65 | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
66 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
67 | LOBBY_FLR_1_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 4 | No | No |
68 | LOBBY_FLR_1_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 4 | No | No |
69 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 1 | No | No |
70 | LOBBY_FLR_1_WALL_1_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 3 | No | No |
71 | LOBBY_FLR_1_WALL_2_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
72 | LOBBY_FLR_1_WALL_3_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
73 | LOBBY_FLR_1_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
74 | LOBBY_FLR_1_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
75 | LOBBY_FLR_1_WALL_4_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
76 | LOBBY_FLR_1_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
77 | LOBBY_FLR_1_WALL_4_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
78 | LOBBY_FLR_1_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
79 | LOBBY_FLR_1_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
80 | LOBBY_FLR_1_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
81 | LOBBY_FLR_1_FLOOR_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
82 | LOBBY_FLR_1_FLOOR_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
83 | LOBBY_FLR_1_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
84 | LOBBY_FLR_1_CEILING_2 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
85 | LOBBY_FLR_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.96 | 109.73 | 24.95 | 0.20 | 0 | No | No |
86 | ROOM_1_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
87 | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
88 | ROOM_1_FLR_3_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
89 | ROOM_1_FLR_3_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
90 | ROOM_1_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
91 | ROOM_1_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
92 | ROOM_1_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
93 | ROOM_1_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
94 | ROOM_1_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
95 | ROOM_2_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
96 | ROOM_2_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
97 | ROOM_2_FLR_3_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
98 | ROOM_2_FLR_3_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
99 | ROOM_2_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
100 | ROOM_2_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
101 | ROOM_2_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
102 | ROOM_2_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
103 | ROOM_2_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
104 | ROOM_3_MULT19_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 3 | No | No |
105 | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 2 | No | No |
106 | ROOM_3_MULT19_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
107 | ROOM_3_MULT19_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
108 | ROOM_3_MULT19_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
109 | ROOM_3_MULT19_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
110 | ROOM_3_MULT19_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
111 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
112 | ROOM_4_MULT19_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 3 | No | No |
113 | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 2 | No | No |
114 | ROOM_4_MULT19_FLR_3_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
115 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
116 | ROOM_4_MULT19_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
117 | ROOM_4_MULT19_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
118 | ROOM_4_MULT19_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
119 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 3.66 | 4.73 | 0.33 | 0 | No | No |
120 | ROOM_5_FLR_3_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
121 | ROOM_5_FLR_3_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
122 | ROOM_5_FLR_3_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
123 | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
124 | ROOM_5_FLR_3_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
125 | ROOM_5_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
126 | ROOM_5_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
127 | ROOM_5_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
128 | ROOM_5_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
129 | ROOM_6_FLR_3_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
130 | ROOM_6_FLR_3_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
131 | ROOM_6_FLR_3_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
132 | ROOM_6_FLR_3_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
133 | ROOM_6_FLR_3_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
134 | ROOM_6_FLR_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
135 | ROOM_6_FLR_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
136 | ROOM_6_FLR_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
137 | ROOM_6_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
138 | CORRIDOR_FLR_3_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
139 | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
140 | CORRIDOR_FLR_3_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
141 | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
142 | CORRIDOR_FLR_3_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
143 | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
144 | CORRIDOR_FLR_3_WALL_2_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 3 | No | No |
145 | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 2 | No | No |
146 | CORRIDOR_FLR_3_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
147 | CORRIDOR_FLR_3_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
148 | CORRIDOR_FLR_3_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
149 | CORRIDOR_FLR_3_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
150 | CORRIDOR_FLR_3_WALL_4_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
151 | CORRIDOR_FLR_3_WALL_3_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
152 | CORRIDOR_FLR_3_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
153 | CORRIDOR_FLR_3_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
154 | CORRIDOR_FLR_3_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
155 | CORRIDOR_FLR_3_WALL_4_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
156 | CORRIDOR_FLR_3_FLOOR_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
157 | CORRIDOR_FLR_3_FLOOR_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
158 | CORRIDOR_FLR_3_FLOOR_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
159 | CORRIDOR_FLR_3_CEILING_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
160 | CORRIDOR_FLR_3_CEILING_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
161 | CORRIDOR_FLR_3_CEILING_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
162 | CORRIDOR_FLR_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 15.85 | 8.24 | 0.33 | 0 | No | No |
163 | ROOM_1_FLR_6_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
164 | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
165 | ROOM_1_FLR_6_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
166 | ROOM_1_FLR_6_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
167 | ROOM_1_FLR_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
168 | ROOM_1_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
169 | ROOM_1_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
170 | ROOM_1_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
171 | ROOM_1_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
172 | ROOM_2_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
173 | ROOM_2_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
174 | ROOM_2_FLR_6_WALL_WEST | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 3 | No | No |
175 | ROOM_2_FLR_6_WALL_WEST_WINDOW | 0 | 194.63 | 84.12 | 19.20 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 2 | No | No |
176 | ROOM_2_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
177 | ROOM_2_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
178 | ROOM_2_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
179 | ROOM_2_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
180 | ROOM_2_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 13.11 | 5.95 | 0.33 | 0 | No | No |
181 | ROOM_3_MULT9_FLR_6_WALL_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 3 | No | No |
182 | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 2 | No | No |
183 | ROOM_3_MULT9_FLR_6_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
184 | ROOM_3_MULT9_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
185 | ROOM_3_MULT9_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
186 | ROOM_3_MULT9_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
187 | ROOM_3_MULT9_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
188 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 6.71 | 4.73 | 0.33 | 0 | No | No |
189 | BANQUET_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 3 | No | No |
190 | BANQUET_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 2 | No | No |
191 | BANQUET_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
192 | BANQUET_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
193 | BANQUET_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
194 | BANQUET_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
195 | BANQUET_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
196 | BANQUET_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
197 | DINING_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 3 | No | No |
198 | DINING_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 2 | No | No |
199 | DINING_FLR_6_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
200 | DINING_FLR_6_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
201 | DINING_FLR_6_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
202 | DINING_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
203 | DINING_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
204 | DINING_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 32.00 | 15.66 | 0.33 | 0 | No | No |
205 | KITCHEN_FLR_6_WALL_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
206 | KITCHEN_FLR_6_WALL_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
207 | KITCHEN_FLR_6_WALL_EAST | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
208 | KITCHEN_FLR_6_WALL_EAST_WINDOW | 0 | 194.63 | 217.46 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
209 | KITCHEN_FLR_6_WALL_1_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 3 | No | No |
210 | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 2 | No | No |
211 | KITCHEN_FLR_6_WALL_2_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
212 | KITCHEN_FLR_6_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
213 | KITCHEN_FLR_6_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
214 | KITCHEN_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
215 | KITCHEN_FLR_6_CEILING | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
216 | KITCHEN_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.65 | 8.58 | 0.30 | 0 | No | No |
217 | CORRIDOR_FLR_6_WALL_1_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
218 | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
219 | CORRIDOR_FLR_6_WALL_2_NORTH | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
220 | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | 0 | 670.01 | 217.46 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
221 | CORRIDOR_FLR_6_WALL_2_SOUTH | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 3 | No | No |
222 | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | 0 | 506.51 | 211.91 | 19.20 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 2 | No | No |
223 | CORRIDOR_FLR_6_WALL_3_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
224 | CORRIDOR_FLR_6_WALL_4_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
225 | CORRIDOR_FLR_6_WALL_1_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
226 | CORRIDOR_FLR_6_WALL_1_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
227 | CORRIDOR_FLR_6_WALL_2_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
228 | CORRIDOR_FLR_6_WALL_3_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
229 | CORRIDOR_FLR_6_WALL_1_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
230 | CORRIDOR_FLR_6_WALL_2_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
231 | CORRIDOR_FLR_6_WALL_3_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
232 | CORRIDOR_FLR_6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
233 | CORRIDOR_FLR_6_CEILING_1 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
234 | CORRIDOR_FLR_6_CEILING_2 | 0 | 1782.60 | 293.11 | 15.24 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
235 | CORRIDOR_FLR_6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 3.05 | 28.04 | 8.72 | 0.33 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | RETAIL_1_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | RETAIL_1_FLR_1 | 67.07 | 10.8 | 7.733E-002 | 1.153E-003 | 5.690E-004 | 1.047 | 1.000 | 0.000 | 0.000 | 0.000 |
2 | RETAIL_2_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | RETAIL_2_FLR_1 | 77.67 | 12.5 | 1.623E-002 | 2.089E-004 | 5.690E-004 | 0.190 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | MECH_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | MECH_FLR_1 | 164.24 | 0.0 | 3.573E-002 | 2.175E-004 | 5.690E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
4 | STORAGE_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | STORAGE_FLR_1 | 94.76 | 0.0 | 2.484E-002 | 2.622E-004 | 5.690E-004 | 0.238 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | LAUNDRY_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | LAUNDRY_FLR_1 | 78.04 | 8.4 | 4.990E-002 | 6.394E-004 | 5.690E-004 | 0.581 | 1.000 | 0.000 | 0.000 | 0.000 |
6 | CAFE_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | CAFE_FLR_1 | 188.86 | 142.3 | 0.195 | 1.033E-003 | 5.690E-004 | 0.939 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | LOBBY_FLR_1_INFILTRATION | INFIL_QUARTER_ON_SCH | LOBBY_FLR_1 | 1308.19 | 422.4 | 0.389 | 2.975E-004 | 5.690E-004 | 0.270 | 1.000 | 0.000 | 0.000 | 0.000 |
8 | ROOM_1_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_1_FLR_3 | 39.02 | 1.5 | 2.273E-002 | 5.825E-004 | 5.690E-004 | 0.688 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | ROOM_2_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_2_FLR_3 | 39.02 | 1.5 | 2.273E-002 | 5.825E-004 | 5.690E-004 | 0.688 | 1.000 | 0.000 | 0.000 | 0.000 |
10 | ROOM_3_MULT19_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 6.342E-003 | 2.586E-004 | 5.690E-004 | 0.305 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | ROOM_4_MULT19_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 6.344E-003 | 2.586E-004 | 5.690E-004 | 0.305 | 1.000 | 0.000 | 0.000 | 0.000 |
12 | ROOM_5_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_5_FLR_3 | 39.02 | 1.5 | 2.273E-002 | 5.825E-004 | 5.690E-004 | 0.688 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | ROOM_6_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_6_FLR_3 | 39.02 | 1.5 | 2.273E-002 | 5.825E-004 | 5.690E-004 | 0.688 | 1.000 | 0.000 | 0.000 | 0.000 |
14 | CORRIDOR_FLR_3_INFILTRATION | INFIL_QUARTER_ON_SCH | CORRIDOR_FLR_3 | 389.40 | 0.0 | 2.749E-002 | 7.058E-005 | 5.690E-004 | 8.337E-002 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | ROOM_1_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_1_FLR_6 | 39.02 | 1.5 | 2.273E-002 | 5.825E-004 | 2.878E-004 | 0.688 | 1.000 | 0.000 | 0.000 | 0.000 |
16 | ROOM_2_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_2_FLR_6 | 39.02 | 1.5 | 2.273E-002 | 5.825E-004 | 2.878E-004 | 0.688 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | ROOM_3_MULT9_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 1.163E-002 | 4.741E-004 | 2.586E-004 | 0.560 | 1.000 | 0.000 | 0.000 | 0.000 |
18 | BANQUET_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | BANQUET_FLR_6 | 331.66 | 249.9 | 5.551E-002 | 1.674E-004 | 1.293E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | DINING_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | DINING_FLR_6 | 331.66 | 249.9 | 5.551E-002 | 1.674E-004 | 1.293E-004 | 0.198 | 1.000 | 0.000 | 0.000 | 0.000 |
20 | KITCHEN_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | KITCHEN_FLR_6 | 103.30 | 22.2 | 4.969E-002 | 4.810E-004 | 2.606E-004 | 0.568 | 1.000 | 0.000 | 0.000 | 0.000 |
21 | CORRIDOR_FLR_6_INFILTRATION | INFIL_QUARTER_ON_SCH | CORRIDOR_FLR_6 | 412.12 | 0.0 | 4.864E-002 | 1.180E-004 | 9.775E-005 | 0.139 | 1.000 | 0.000 | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | ROOM_1_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_1_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
2 | ROOM_2_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_2_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
3 | ROOM_3_MULT19_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_3_MULT19_FLR_3 | 24.52 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
4 | ROOM_4_MULT19_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_4_MULT19_FLR_3 | 24.53 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
5 | ROOM_5_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_5_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
6 | ROOM_6_FLR_3 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_6_FLR_3 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
7 | ROOM_1_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_1_FLR_6 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
8 | ROOM_2_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_2_FLR_6 | 39.02 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
9 | ROOM_3_MULT9_FLR_6 SLIDING DOOR VENTILATION | Constant-0.0 | ROOM_3_MULT9_FLR_6 | 24.53 | 1.5 | 0.000 | 0.000 | 0.000 | 0.000 | Natural | 0.000 | 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 18.89 | 25.56 | -100.00 | 15.56 | 26.67 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BASEMENT | Mixing/Well-Stirred |
2 | RETAIL_1_FLR_1 | Mixing/Well-Stirred |
3 | RETAIL_2_FLR_1 | Mixing/Well-Stirred |
4 | MECH_FLR_1 | Mixing/Well-Stirred |
5 | STORAGE_FLR_1 | Mixing/Well-Stirred |
6 | LAUNDRY_FLR_1 | Mixing/Well-Stirred |
7 | CAFE_FLR_1 | Mixing/Well-Stirred |
8 | LOBBY_FLR_1 | Mixing/Well-Stirred |
9 | ROOM_1_FLR_3 | Mixing/Well-Stirred |
10 | ROOM_2_FLR_3 | Mixing/Well-Stirred |
11 | ROOM_3_MULT19_FLR_3 | Mixing/Well-Stirred |
12 | ROOM_4_MULT19_FLR_3 | Mixing/Well-Stirred |
13 | ROOM_5_FLR_3 | Mixing/Well-Stirred |
14 | ROOM_6_FLR_3 | Mixing/Well-Stirred |
15 | CORRIDOR_FLR_3 | Mixing/Well-Stirred |
16 | ROOM_1_FLR_6 | Mixing/Well-Stirred |
17 | ROOM_2_FLR_6 | Mixing/Well-Stirred |
18 | ROOM_3_MULT9_FLR_6 | Mixing/Well-Stirred |
19 | BANQUET_FLR_6 | Mixing/Well-Stirred |
20 | DINING_FLR_6 | Mixing/Well-Stirred |
21 | KITCHEN_FLR_6 | Mixing/Well-Stirred |
22 | CORRIDOR_FLR_6 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BASEMENT | Cooling | 31903.53783 | 31903.53783 | 2.36195 | 2.36195 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 20:00:00 | 26.85000 | 8.20219E-003 | 1978.83018 | 106.49900 | 0.85413 | 0.00000 |
2 | BASEMENT | Heating | 0.00000 | 0.00000 | 0.00000 | 0.85413 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80000 | 5.05843E-003 | 1978.83018 | 106.49900 | 0.85413 | 0.00000 | |
3 | RETAIL_1_FLR_1 | Cooling | 3959.02437 | 3959.02437 | 0.29312 | 0.29312 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | 30.92917 | 8.20219E-003 | 67.07136 | 10.82900 | 7.91874E-002 | 0.00000 |
4 | RETAIL_1_FLR_1 | Heating | 1936.58406 | 1936.58406 | 8.45773E-002 | 8.45773E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 67.07136 | 10.82900 | 7.91874E-002 | 0.00000 |
5 | RETAIL_2_FLR_1 | Cooling | 3109.49277 | 3109.49277 | 0.23023 | 0.23023 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:50:00 | 30.17267 | 8.20219E-003 | 77.66889 | 12.54000 | 9.16993E-002 | 0.00000 |
6 | RETAIL_2_FLR_1 | Heating | 572.60358 | 572.60358 | 2.50083E-002 | 9.16993E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 77.66889 | 12.54000 | 9.16993E-002 | 0.00000 |
7 | MECH_FLR_1 | Cooling | 2854.35705 | 2854.35705 | 0.21129 | 0.21129 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:20:00 | 29.75733 | 8.20219E-003 | 164.24319 | 0.00000 | 0.00000 | 0.00000 |
8 | MECH_FLR_1 | Heating | 973.59556 | 973.59556 | 4.25215E-002 | 4.25215E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 164.24319 | 0.00000 | 0.00000 | 0.00000 |
9 | STORAGE_FLR_1 | Cooling | 1320.77574 | 1320.77574 | 9.77690E-002 | 9.77690E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 31.21100 | 8.20220E-003 | 94.75927 | 0.00000 | 5.77430E-002 | 0.00000 |
10 | STORAGE_FLR_1 | Heating | 626.45462 | 626.45462 | 2.73602E-002 | 5.77430E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 94.75927 | 0.00000 | 5.77430E-002 | 0.00000 |
11 | LAUNDRY_FLR_1 | Cooling | 44738.65773 | 44738.65773 | 3.31212 | 3.31212 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 31.30000 | 8.20219E-003 | 78.03947 | 8.40000 | 0.23597 | 0.00000 |
12 | LAUNDRY_FLR_1 | Heating | 1306.12240 | 1306.12240 | 5.70437E-002 | 0.23597 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 78.03947 | 8.40000 | 0.23597 | 0.00000 |
13 | CAFE_FLR_1 | Cooling | 17228.80452 | 17228.80452 | 1.27667 | 1.27667 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | 30.92917 | 8.20219E-003 | 188.86188 | 142.30000 | 0.67613 | 0.00000 |
14 | CAFE_FLR_1 | Heating | 5023.63535 | 5023.63535 | 0.21940 | 0.67613 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 188.86188 | 142.30000 | 0.67613 | 0.00000 |
15 | LOBBY_FLR_1 | Cooling | 60722.47617 | 60722.47617 | 4.49724 | 4.49724 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 31.00333 | 8.20219E-003 | 1308.18612 | 422.43500 | 1.89326 | 0.00000 |
16 | LOBBY_FLR_1 | Heating | 10831.41918 | 10831.41918 | 0.47306 | 1.89326 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 1308.18612 | 422.43500 | 1.89326 | 0.00000 |
17 | ROOM_1_FLR_3 | Cooling | 8953.89438 | 8953.89438 | 0.89324 | 0.89324 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 30.41000 | 8.20219E-003 | 39.02202 | 1.50000 | 6.17129E-002 | 0.00000 |
18 | ROOM_1_FLR_3 | Heating | 3634.44894 | 3634.44894 | 0.15966 | 0.15966 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 39.02202 | 1.50000 | 6.17129E-002 | 0.00000 |
19 | ROOM_2_FLR_3 | Cooling | 8742.09173 | 8742.09173 | 0.87211 | 0.87211 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 30.41000 | 8.20219E-003 | 39.01745 | 1.50000 | 6.17056E-002 | 0.00000 |
20 | ROOM_2_FLR_3 | Heating | 3635.01214 | 3635.01214 | 0.15969 | 0.15969 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 39.01745 | 1.50000 | 6.17056E-002 | 0.00000 |
21 | ROOM_3_MULT19_FLR_3 | Cooling | 48908.83742 | 48908.83742 | 4.87892 | 4.87892 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 31.00333 | 8.20219E-003 | 24.52384 | 1.50000 | 0.83677 | 0.00000 |
22 | ROOM_3_MULT19_FLR_3 | Heating | 21042.70779 | 21042.70779 | 0.92443 | 0.92443 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 24.52384 | 1.50000 | 0.83677 | 0.00000 |
23 | ROOM_4_MULT19_FLR_3 | Cooling | 50341.75420 | 50341.75420 | 5.02226 | 5.02226 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | 31.30000 | 8.20219E-003 | 24.53055 | 1.50000 | 0.83699 | 0.00000 |
24 | ROOM_4_MULT19_FLR_3 | Heating | 21088.34169 | 21088.34169 | 0.92644 | 0.92644 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 24.53055 | 1.50000 | 0.83699 | 0.00000 |
25 | ROOM_5_FLR_3 | Cooling | 7744.57557 | 7744.57557 | 0.77260 | 0.77260 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 | 26.65717 | 8.20219E-003 | 39.02202 | 1.50000 | 6.17129E-002 | 0.00000 |
26 | ROOM_5_FLR_3 | Heating | 3633.75181 | 3633.75181 | 0.15963 | 0.15963 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 39.02202 | 1.50000 | 6.17129E-002 | 0.00000 |
27 | ROOM_6_FLR_3 | Cooling | 7667.17473 | 7667.17473 | 0.76488 | 0.76488 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 26.40500 | 8.20219E-003 | 39.01745 | 1.50000 | 6.17056E-002 | 0.00000 |
28 | ROOM_6_FLR_3 | Heating | 3634.31560 | 3634.31560 | 0.15966 | 0.15966 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 39.01745 | 1.50000 | 6.17056E-002 | 0.00000 |
29 | CORRIDOR_FLR_3 | Cooling | 11546.50134 | 11546.50134 | 0.85472 | 1.18691 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:10:00 | 31.30000 | 8.20219E-003 | 389.40468 | 0.00000 | 0.47458 | 0.00000 |
30 | CORRIDOR_FLR_3 | Heating | 5685.48636 | 5685.48636 | 0.24831 | 0.47458 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 389.40468 | 0.00000 | 0.47458 | 0.00000 |
31 | ROOM_1_FLR_6 | Cooling | 2313.13032 | 2313.13032 | 0.23076 | 0.23076 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 30.41000 | 8.20219E-003 | 39.02202 | 1.50000 | 1.54282E-002 | 0.00000 |
32 | ROOM_1_FLR_6 | Heating | 1127.98337 | 1127.98337 | 4.95530E-002 | 4.95530E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 39.02202 | 1.50000 | 1.54282E-002 | 0.00000 |
33 | ROOM_2_FLR_6 | Cooling | 2258.67419 | 2258.67419 | 0.22532 | 0.22532 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 30.41000 | 8.20219E-003 | 39.01745 | 1.50000 | 1.54264E-002 | 0.00000 |
34 | ROOM_2_FLR_6 | Heating | 1129.93522 | 1129.93522 | 4.96387E-002 | 4.96387E-002 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 39.01745 | 1.50000 | 1.54264E-002 | 0.00000 |
35 | ROOM_3_MULT9_FLR_6 | Cooling | 9958.87951 | 9958.87951 | 0.99352 | 0.99352 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 31.07750 | 8.20219E-003 | 24.53055 | 1.50000 | 9.91178E-002 | 0.00000 |
36 | ROOM_3_MULT9_FLR_6 | Heating | 5463.04009 | 5463.04009 | 0.24000 | 0.24000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 24.53055 | 1.50000 | 9.91178E-002 | 0.00000 |
37 | BANQUET_FLR_6 | Cooling | 28119.31174 | 28119.31174 | 2.08433 | 2.08433 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:10:00 | 31.30000 | 8.20219E-003 | 331.65745 | 249.89600 | 1.18734 | 0.00000 |
38 | BANQUET_FLR_6 | Heating | 3778.22931 | 3778.22931 | 0.16501 | 1.18734 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | 3.80000 | 5.05843E-003 | 331.65745 | 249.89600 | 1.18734 | 0.00000 |
39 | DINING_FLR_6 | Cooling | 29533.83220 | 29533.83220 | 2.18914 | 2.18914 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:10:00 | 31.30000 | 8.20219E-003 | 331.65745 | 249.89600 | 1.18734 | 0.00000 |
40 | DINING_FLR_6 | Heating | 3786.63365 | 3786.63365 | 0.16538 | 1.18734 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 3.80000 | 5.05843E-003 | 331.65745 | 249.89600 | 1.18734 | 0.00000 |
41 | KITCHEN_FLR_6 | Cooling | 29925.79770 | 29925.79770 | 2.22129 | 2.22129 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 12:30:00 | 30.49900 | 8.20219E-003 | 103.30446 | 22.23800 | 0.36721 | 0.00000 |
42 | KITCHEN_FLR_6 | Heating | 0.00000 | 0.00000 | 0.00000 | 0.36721 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80000 | 5.05843E-003 | 103.30446 | 22.23800 | 0.36721 | 0.00000 | |
43 | CORRIDOR_FLR_6 | Cooling | 7399.48037 | 7399.48037 | 0.54774 | 0.54774 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 31.22583 | 8.20219E-003 | 412.12471 | 0.00000 | 0.12557 | 0.00000 |
44 | CORRIDOR_FLR_6 | Heating | 4017.88295 | 4017.88295 | 0.17548 | 0.17548 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 3.80000 | 5.05843E-003 | 412.12471 | 0.00000 | 0.12557 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | VAV WITH REHEAT | Cooling | Sensible | 371099.51 | 20.06331 | 20.06331 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
2 | VAV WITH REHEAT | Heating | Sensible | 112253.29 | 7.32771 | 7.32771 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 |
3 | FLR_3_DOAS | Cooling | Sensible | 45063.05 | 13.86243 | 2.05120 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
4 | FLR_3_DOAS | Heating | Sensible | 31422.35 | 2.82870 | 2.05120 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.36195 |
2 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.63840 |
3 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
4 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.38882 |
5 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
6 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.96804E-004 |
8 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.59001E-004 |
9 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.38882 |
10 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
11 | AirTerminal:SingleDuct:VAV:Reheat | BASEMENT VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
12 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 7196.63140 |
13 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.59001E-004 |
14 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 127.34782 |
15 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.29312 |
16 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.17436 |
17 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
18 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.17236 |
19 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58800 |
20 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
21 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.18517E-003 |
22 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.24955E-005 |
23 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.17236 |
24 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
25 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_1_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
26 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 2828.64922 |
27 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.24955E-005 |
28 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 55.95088 |
29 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.23023 |
30 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.25706 |
31 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
32 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13538 |
33 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.68549 |
34 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
35 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.48214E-003 |
36 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.81371E-005 |
37 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.13538 |
38 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | RETAIL_2_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
40 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 1273.53204 |
41 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.81371E-005 |
42 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 23.62043 |
43 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.21129 |
44 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.59233 |
45 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
46 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.12424 |
47 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
48 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
49 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.43225E-004 |
50 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.57198E-005 |
51 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.12424 |
52 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
53 | AirTerminal:SingleDuct:VAV:Reheat | MECH_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
54 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 1616.73460 |
55 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.57198E-005 |
56 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 31.28097 |
57 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 9.77690E-002 |
58 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.73854 |
59 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
60 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 5.74882E-002 |
61 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
62 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.15881E-004 |
64 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.04153E-005 |
65 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.74882E-002 |
66 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
67 | AirTerminal:SingleDuct:VAV:Reheat | STORAGE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
68 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 924.02919 |
69 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.04153E-005 |
70 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 18.23685 |
71 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 3.31212 |
72 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 7.12455E-002 |
73 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
74 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.94753 |
75 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58800 |
76 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
77 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.12208E-002 |
78 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.51579E-004 |
79 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.94753 |
80 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
81 | AirTerminal:SingleDuct:VAV:Reheat | LAUNDRY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
82 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 11386.88869 |
83 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.51579E-004 |
84 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 202.95555 |
85 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.27667 |
86 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11273 |
87 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
88 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.75068 |
89 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58800 |
90 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
91 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.37990E-003 |
92 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.96835E-004 |
93 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.75068 |
94 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | CAFE_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
96 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 8909.05396 |
97 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.96835E-004 |
98 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 170.02884 |
99 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 4.49724 |
100 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.22166 |
101 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
102 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 2.64437 |
103 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.59108 |
104 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
105 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.71888E-003 |
106 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.41749E-004 |
107 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.64437 |
108 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
109 | AirTerminal:SingleDuct:VAV:Reheat | LOBBY_FLR_1 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
110 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 24520.44085 |
111 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.41749E-004 |
112 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 454.08430 |
113 | AirTerminal:SingleDuct:Uncontrolled | ROOM_1_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.89324 |
114 | AirTerminal:SingleDuct:Uncontrolled | ROOM_1_FLR_3 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 6.17331E-002 |
115 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.89324 |
116 | Fan:OnOff | ROOM_1_FLR_3 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.89324 |
117 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 8.02986E-005 |
118 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 3.49453E-004 |
119 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 3.49453E-004 |
120 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.89324 |
121 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.57515E-003 |
122 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69394 |
123 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
124 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
125 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
126 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 3634.44425 |
127 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.02986E-005 |
128 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 82.74034 |
129 | AirTerminal:SingleDuct:Uncontrolled | ROOM_2_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.87211 |
130 | AirTerminal:SingleDuct:Uncontrolled | ROOM_2_FLR_3 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 6.17331E-002 |
131 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.87211 |
132 | Fan:OnOff | ROOM_2_FLR_3 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.87211 |
133 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 8.03110E-005 |
134 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 3.41351E-004 |
135 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 3.41351E-004 |
136 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.87211 |
137 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.57691E-003 |
138 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69394 |
139 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
140 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
141 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
142 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 3635.00745 |
143 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.03110E-005 |
144 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 82.75316 |
145 | AirTerminal:SingleDuct:Uncontrolled | ROOM_3_MULT19_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 4.87892 |
146 | AirTerminal:SingleDuct:Uncontrolled | ROOM_3_MULT19_FLR_3 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 0.83695 |
147 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 4.87892 |
148 | Fan:OnOff | ROOM_3_MULT19_FLR_3 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 4.87892 |
149 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 4.64913E-004 |
150 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT19_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 1.86947E-003 |
151 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 1.86947E-003 |
152 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 4.87892 |
153 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.49315E-003 |
154 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69439 |
155 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
156 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
157 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.49315E-003 |
158 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 21042.69399 |
159 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.64913E-004 |
160 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 479.04599 |
161 | AirTerminal:SingleDuct:Uncontrolled | ROOM_4_MULT19_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 5.02226 |
162 | AirTerminal:SingleDuct:Uncontrolled | ROOM_4_MULT19_FLR_3 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 0.83695 |
163 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 5.02226 |
164 | Fan:OnOff | ROOM_4_MULT19_FLR_3 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 5.02226 |
165 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 4.65921E-004 |
166 | ZoneHVAC:FourPipeFanCoil | ROOM_4_MULT19_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 2.07118E-003 |
167 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 2.07118E-003 |
168 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 5.02226 |
169 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.77281E-003 |
170 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69343 |
171 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
172 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
173 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
174 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 21088.32786 |
175 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.65921E-004 |
176 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 480.08476 |
177 | AirTerminal:SingleDuct:Uncontrolled | ROOM_5_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.77260 |
178 | AirTerminal:SingleDuct:Uncontrolled | ROOM_5_FLR_3 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 6.17331E-002 |
179 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.77260 |
180 | Fan:OnOff | ROOM_5_FLR_3 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.77260 |
181 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 8.02832E-005 |
182 | ZoneHVAC:FourPipeFanCoil | ROOM_5_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 3.03213E-004 |
183 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 3.03213E-004 |
184 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.77260 |
185 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.58672E-003 |
186 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69393 |
187 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
188 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
189 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
190 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 3633.74712 |
191 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.02832E-005 |
192 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 82.72447 |
193 | AirTerminal:SingleDuct:Uncontrolled | ROOM_6_FLR_3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.76488 |
194 | AirTerminal:SingleDuct:Uncontrolled | ROOM_6_FLR_3 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 6.17331E-002 |
195 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.76488 |
196 | Fan:OnOff | ROOM_6_FLR_3 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.76488 |
197 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 8.02957E-005 |
198 | ZoneHVAC:FourPipeFanCoil | ROOM_6_FLR_3 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 3.00250E-004 |
199 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 3.00250E-004 |
200 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.76488 |
201 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.58753E-003 |
202 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69392 |
203 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
204 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
205 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
206 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 3634.31091 |
207 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.02957E-005 |
208 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 82.73730 |
209 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.18691 |
210 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 1.00000 |
211 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
212 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.69790 |
213 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
214 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
215 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.81000E-004 |
216 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.05468E-004 |
217 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.69790 |
218 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
219 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_3 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
220 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 9299.80675 |
221 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.05468E-004 |
222 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 180.47615 |
223 | AirTerminal:SingleDuct:Uncontrolled | ROOM_1_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.23076 |
224 | AirTerminal:SingleDuct:Uncontrolled | ROOM_1_FLR_6 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 1.54333E-002 |
225 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.23076 |
226 | Fan:OnOff | ROOM_1_FLR_6 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.23076 |
227 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 2.49214E-005 |
228 | ZoneHVAC:FourPipeFanCoil | ROOM_1_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 9.02198E-005 |
229 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 9.02198E-005 |
230 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.23076 |
231 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.57284E-003 |
232 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69395 |
233 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
234 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
235 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
236 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 1127.98200 |
237 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.49214E-005 |
238 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 25.67857 |
239 | AirTerminal:SingleDuct:Uncontrolled | ROOM_2_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.22532 |
240 | AirTerminal:SingleDuct:Uncontrolled | ROOM_2_FLR_6 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 1.54333E-002 |
241 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.22532 |
242 | Fan:OnOff | ROOM_2_FLR_6 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.22532 |
243 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 2.49645E-005 |
244 | ZoneHVAC:FourPipeFanCoil | ROOM_2_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 8.81366E-005 |
245 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 8.81366E-005 |
246 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.22532 |
247 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.57453E-003 |
248 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69394 |
249 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
250 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
251 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
252 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 1129.93385 |
253 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.49645E-005 |
254 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 25.72300 |
255 | AirTerminal:SingleDuct:Uncontrolled | ROOM_3_MULT9_FLR_6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.99352 |
256 | AirTerminal:SingleDuct:Uncontrolled | ROOM_3_MULT9_FLR_6 DIRECT AIR | User-Specified Maximum Air Flow Rate [m3/s] | 9.91128E-002 |
257 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.99352 |
258 | Fan:OnOff | ROOM_3_MULT9_FLR_6 FAN COILFAN | Design Size Maximum Flow Rate [m3/s] | 0.99352 |
259 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Hot Water Flow [m3/s] | 1.20699E-004 |
260 | ZoneHVAC:FourPipeFanCoil | ROOM_3_MULT9_FLR_6 FAN COIL | Design Size Maximum Cold Water Flow [m3/s] | 3.97659E-004 |
261 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Design Size Design Water Flow Rate [m3/s] | 3.97659E-004 |
262 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | User-Specified Design Air Flow Rate [m3/s] | 0.99352 |
263 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Air Humidity Ratio | 8.65947E-003 |
264 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Air Temperature [C] | 21.69362 |
265 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Design Size Design Inlet Water Temperature [C] | 6.70000 |
266 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Design Size Design Outlet Air Temperature [C] | 12.80000 |
267 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Design Size Design Outlet Air Humidity Ratio | 8.50000E-003 |
268 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | Design Size Rated Capacity [W] | 5463.03488 |
269 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.20699E-004 |
270 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 124.36573 |
271 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.08433 |
272 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12125 |
273 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
274 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.22559 |
275 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58800 |
276 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
277 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.14229E-003 |
278 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.23717E-004 |
279 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.22559 |
280 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
281 | AirTerminal:SingleDuct:VAV:Reheat | BANQUET_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
282 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10125.80965 |
283 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.23717E-004 |
284 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 185.37547 |
285 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.18914 |
286 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11544 |
287 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
288 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.28722 |
289 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58800 |
290 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
291 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.30031E-003 |
292 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.30959E-004 |
293 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.28722 |
294 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
295 | AirTerminal:SingleDuct:VAV:Reheat | DINING_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
296 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 10453.58326 |
297 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.30959E-004 |
298 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 191.07251 |
299 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.22129 |
300 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.70000 |
301 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
302 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 1.30612 |
303 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58800 |
304 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
305 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.07512E-002 |
306 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.49532E-004 |
307 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.30612 |
308 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
309 | AirTerminal:SingleDuct:VAV:Reheat | KITCHEN_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
310 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 6768.07202 |
311 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.49532E-004 |
312 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 119.76426 |
313 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.54774 |
314 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.57334 |
315 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.58800 |
316 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.32207 |
317 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
318 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
319 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.64531E-004 |
320 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.25628E-004 |
321 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.32207 |
322 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 16.70000 |
323 | AirTerminal:SingleDuct:VAV:Reheat | CORRIDOR_FLR_6 VAV BOX COMPONENT | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
324 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size Rated Capacity [W] | 5686.13800 |
325 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.25628E-004 |
326 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 113.40764 |
327 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 12.05976 |
328 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 12.05976 |
329 | AirLoopHVAC | VAV WITH REHEAT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 20.50980 |
330 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Heating Design Air Flow Rate [m3/s] | 12.05976 |
331 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Cooling Design Air Flow Rate [m3/s] | 20.06331 |
332 | AirLoopHVAC | VAV WITH REHEAT | Adjusted Main Design Air Flow Rate [m3/s] | 20.06331 |
333 | AirLoopHVAC | VAV WITH REHEAT | User Heating Air Flow Ratio [] | 0.30000 |
334 | AirLoopHVAC | VAV WITH REHEAT | Calculated Heating Air Flow Ratio [] | 0.60109 |
335 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.05082 |
336 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.05082 |
337 | AirLoopHVAC | FLR_3_DOAS | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.05082 |
338 | AirLoopHVAC | FLR_3_DOAS | Adjusted Heating Design Air Flow Rate [m3/s] | 2.05120 |
339 | AirLoopHVAC | FLR_3_DOAS | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.05120 |
340 | AirLoopHVAC | FLR_3_DOAS | Adjusted Main Design Air Flow Rate [m3/s] | 2.05120 |
341 | AirLoopHVAC | FLR_3_DOAS | User Heating Air Flow Ratio [] | 0.30000 |
342 | AirLoopHVAC | FLR_3_DOAS | Calculated Heating Air Flow Ratio [] | 1.00000 |
343 | AirLoopHVAC | VAV WITH REHEAT | Design Supply Air Flow Rate [m3/s] | 20.06331 |
344 | AirLoopHVAC | FLR_3_DOAS | Design Supply Air Flow Rate [m3/s] | 2.05120 |
345 | Controller:OutdoorAir | VAV WITH REHEAT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 20.06331 |
346 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Coil Load [W] | 439146.39089 |
347 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Water Flow Rate [m3/s] | 1.56853E-002 |
348 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Air Flow Rate [m3/s] | 20.06331 |
349 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Inlet Air Humidity Ratio | 8.78275E-003 |
350 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Inlet Air Temperature [C] | 28.38159 |
351 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Inlet Water Temperature [C] | 6.70000 |
352 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Outlet Air Temperature [C] | 10.94331 |
353 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | Design Size Design Outlet Air Humidity Ratio | 8.43576E-003 |
354 | Coil:Heating:Water | VAV WITH REHEAT_HEATC | Design Size Rated Capacity [W] | 92205.04039 |
355 | Coil:Heating:Water | VAV WITH REHEAT_HEATC | Design Size Maximum Water Flow Rate [m3/s] | 2.03716E-003 |
356 | Coil:Heating:Water | VAV WITH REHEAT_HEATC | Design Size U-Factor Times Area Value [W/K] | 1451.96477 |
357 | Fan:VariableVolume | VAV WITH REHEAT_FAN | Design Size Maximum Flow Rate [m3/s] | 20.06331 |
358 | Controller:WaterCoil | VAV WITH REHEAT_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.56853E-002 |
359 | Controller:WaterCoil | VAV WITH REHEAT_COOLC_CONTROLLER | Controller Convergence Tolerance | 3.03590E-005 |
360 | Controller:WaterCoil | VAV WITH REHEAT_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 2.03716E-003 |
361 | Controller:OutdoorAir | FLR_3_DOAS_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.05120 |
362 | Controller:OutdoorAir | FLR_3_DOAS_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 2.05120 |
363 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Coil Load [W] | 47940.87599 |
364 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Water Flow Rate [m3/s] | 1.71234E-003 |
365 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Air Flow Rate [m3/s] | 2.05120 |
366 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Inlet Air Humidity Ratio | 8.20219E-003 |
367 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Inlet Air Temperature [C] | 31.30000 |
368 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Inlet Water Temperature [C] | 6.70000 |
369 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Outlet Air Temperature [C] | 10.94135 |
370 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | Design Size Design Outlet Air Humidity Ratio | 8.20219E-003 |
371 | Coil:Heating:Water | FLR_3_DOAS_HEATC | Design Size Rated Capacity [W] | 9426.70388 |
372 | Coil:Heating:Water | FLR_3_DOAS_HEATC | Design Size Maximum Water Flow Rate [m3/s] | 2.08272E-004 |
373 | Coil:Heating:Water | FLR_3_DOAS_HEATC | Design Size U-Factor Times Area Value [W/K] | 148.44353 |
374 | Fan:ConstantVolume | FLR_3_DOAS_FAN | User-Specified Maximum Flow Rate [m3/s] | 2.05120 |
375 | Controller:WaterCoil | FLR_3_DOAS_COOLC_CONTROLLER | Maximum Actuated Flow [m3/s] | 1.71234E-003 |
376 | Controller:WaterCoil | FLR_3_DOAS_COOLC_CONTROLLER | Controller Convergence Tolerance | 2.78094E-004 |
377 | Controller:WaterCoil | FLR_3_DOAS_HEATC_CONTROLLER | Maximum Actuated Flow [m3/s] | 2.08272E-004 |
378 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Flow Rate [m3/s] | 2.32086E-002 |
379 | Pump:VariableSpeed | COOLSYS1 PUMP SECONDARY | Design Power Consumption [W] | 5558.64944 |
380 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 3.75036E-004 |
381 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 4.50044E-002 |
382 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 3.75036E-004 |
383 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 47.90688 |
384 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 3.75036E-004 |
385 | PlantLoop | HEATSYS1 | Maximum Loop Flow Rate [m3/s] | 5.89927E-003 |
386 | PlantLoop | HEATSYS1 | Plant Loop Volume [m3] | 0.70791 |
387 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Flow Rate [m3/s] | 5.89927E-003 |
388 | Pump:VariableSpeed | HEATSYS1 PUMP | Design Power Consumption [W] | 1507.18857 |
389 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Nominal Capacity [W] | 267010.59619 |
390 | Boiler:HotWater | HEATSYS1 BOILER | User-Specified Nominal Capacity [W] | 267010.60000 |
391 | Boiler:HotWater | HEATSYS1 BOILER | Design Size Design Water Flow Rate [m3/s] | 5.89927E-003 |
392 | PlantLoop | COOLSYS1 | Maximum Loop Flow Rate [m3/s] | 2.32086E-002 |
393 | PlantLoop | COOLSYS1 | Plant Loop Volume [m3] | 2.78503 |
394 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Flow Rate [m3/s] | 2.32086E-002 |
395 | Pump:ConstantSpeed | COOLSYS1 PUMP | Design Power Consumption [W] | 1852.88315 |
396 | Chiller:Electric:EIR | COOLSYS1 CHILLER | Design Size Reference Chilled Water Flow Rate [m3/s] | 2.32086E-002 |
397 | Chiller:Electric:EIR | COOLSYS1 CHILLER | Design Size Reference Capacity [W] | 649777.93903 |
398 | Chiller:Electric:EIR | COOLSYS1 CHILLER | User-Specified Reference Capacity [W] | 650353.95000 |
399 | Chiller:Electric:EIR | COOLSYS1 CHILLER | Design Size Reference Condenser Fluid Flow Rate [m3/s] | 74.14035 |
Component Type | Name | Nominal Total Capacity {W} | |
1 | Coil:Heating:Water | BASEMENT VAV BOX REHEAT COIL | 7237.99 |
2 | Coil:Heating:Water | RETAIL_1_FLR_1 VAV BOX REHEAT COIL | 2846.81 |
3 | Coil:Heating:Water | RETAIL_2_FLR_1 VAV BOX REHEAT COIL | 1280.53 |
4 | Coil:Heating:Water | MECH_FLR_1 VAV BOX REHEAT COIL | 1625.77 |
5 | Coil:Heating:Water | STORAGE_FLR_1 VAV BOX REHEAT COIL | 929.97 |
6 | Coil:Heating:Water | LAUNDRY_FLR_1 VAV BOX REHEAT COIL | 11451.84 |
7 | Coil:Heating:Water | CAFE_FLR_1 VAV BOX REHEAT COIL | 8955.85 |
8 | Coil:Heating:Water | LOBBY_FLR_1 VAV BOX REHEAT COIL | 24655.35 |
9 | Coil:Heating:Water | ROOM_1_FLR_3 FAN COILHEAT COIL | 3921.75 |
10 | Coil:Heating:Water | ROOM_2_FLR_3 FAN COILHEAT COIL | 3922.36 |
11 | Coil:Heating:Water | ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | 22706.07 |
12 | Coil:Heating:Water | ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | 22755.31 |
13 | Coil:Heating:Water | ROOM_5_FLR_3 FAN COILHEAT COIL | 3921.00 |
14 | Coil:Heating:Water | ROOM_6_FLR_3 FAN COILHEAT COIL | 3921.61 |
15 | Coil:Heating:Water | CORRIDOR_FLR_3 VAV BOX REHEAT COIL | 9360.96 |
16 | Coil:Heating:Water | ROOM_1_FLR_6 FAN COILHEAT COIL | 1217.13 |
17 | Coil:Heating:Water | ROOM_2_FLR_6 FAN COILHEAT COIL | 1219.24 |
18 | Coil:Heating:Water | ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | 5894.78 |
19 | Coil:Heating:Water | BANQUET_FLR_6 VAV BOX REHEAT COIL | 10182.08 |
20 | Coil:Heating:Water | DINING_FLR_6 VAV BOX REHEAT COIL | 10511.76 |
21 | Coil:Heating:Water | KITCHEN_FLR_6 VAV BOX REHEAT COIL | 6806.97 |
22 | Coil:Heating:Water | CORRIDOR_FLR_6 VAV BOX REHEAT COIL | 5721.83 |
23 | Coil:Heating:Water | VAV WITH REHEAT_HEATC | 77497.57 |
24 | Coil:Heating:Water | FLR_3_DOAS_HEATC | 7923.07 |
Component Type | Name | Nominal Total Capacity {W} | Nominal Sensible Capacity {W} | Nominal Latent Capacity {W} | Nominal Sensible Heat Ratio | Nominal Coil UA Value {W/C} | Nominal Coil Surface Area {m2} | |
1 | Coil:Cooling:Water | ROOM_1_FLR_3 FAN COILCOOL COIL | 14792.10 | 11901.08 | 2891.03 | 0.80 | 1708.06 | 17.32 |
2 | Coil:Cooling:Water | ROOM_2_FLR_3 FAN COILCOOL COIL | 14446.75 | 11621.76 | 2824.99 | 0.80 | 1668.10 | 16.92 |
3 | Coil:Cooling:Water | ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | 79741.13 | 64506.42 | 15234.71 | 0.81 | 9239.90 | 93.72 |
4 | Coil:Cooling:Water | ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | 86053.99 | 68306.26 | 17747.73 | 0.79 | 9882.91 | 100.24 |
5 | Coil:Cooling:Water | ROOM_5_FLR_3 FAN COILCOOL COIL | 12820.73 | 10306.51 | 2514.23 | 0.80 | 1479.91 | 15.01 |
6 | Coil:Cooling:Water | ROOM_6_FLR_3 FAN COILCOOL COIL | 12694.44 | 10204.39 | 2490.05 | 0.80 | 1465.29 | 14.86 |
7 | Coil:Cooling:Water | ROOM_1_FLR_6 FAN COILCOOL COIL | 3819.78 | 3073.73 | 746.05 | 0.80 | 441.11 | 4.47 |
8 | Coil:Cooling:Water | ROOM_2_FLR_6 FAN COILCOOL COIL | 3730.98 | 3001.92 | 729.06 | 0.80 | 430.83 | 4.37 |
9 | Coil:Cooling:Water | ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | 16698.91 | 13356.13 | 3342.79 | 0.80 | 1923.50 | 19.51 |
10 | Coil:Cooling:Water | VAV WITH REHEAT_COOLC | 557144.35 | 375052.06 | 182092.28 | 0.67 | 85647.31 | 868.68 |
11 | Coil:Cooling:Water | FLR_3_DOAS_COOLC | 56669.74 | 38137.19 | 18532.55 | 0.67 | 7894.17 | 80.07 |
Component Type | Component Name | IPLV in SI Units {W/W} | IPLV in IP Units {Btu/W-h} | |
1 | Chiller:Electric:EIR | COOLSYS1 CHILLER | 4.04 | 13.79 |
Zone Name | # Surfaces | |
1 | BASEMENT | 14 |
2 | RETAIL_1_FLR_1 | 8 |
3 | RETAIL_2_FLR_1 | 8 |
4 | MECH_FLR_1 | 7 |
5 | STORAGE_FLR_1 | 8 |
6 | LAUNDRY_FLR_1 | 8 |
7 | CAFE_FLR_1 | 10 |
8 | LOBBY_FLR_1 | 22 |
9 | ROOM_1_FLR_3 | 9 |
10 | ROOM_2_FLR_3 | 9 |
11 | ROOM_3_MULT19_FLR_3 | 8 |
12 | ROOM_4_MULT19_FLR_3 | 8 |
13 | ROOM_5_FLR_3 | 9 |
14 | ROOM_6_FLR_3 | 9 |
15 | CORRIDOR_FLR_3 | 25 |
16 | ROOM_1_FLR_6 | 9 |
17 | ROOM_2_FLR_6 | 9 |
18 | ROOM_3_MULT9_FLR_6 | 8 |
19 | BANQUET_FLR_6 | 8 |
20 | DINING_FLR_6 | 8 |
21 | KITCHEN_FLR_6 | 12 |
22 | CORRIDOR_FLR_6 | 19 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BASEMENT_WALL_NORTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_NORTH_CFACTOR | 0.940 | 0.824 | 211.13 | 211.13 | 211.13 | 0.00 | 90.00 | 86.56 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BASEMENT_WALL_EAST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_EAST_CFACTOR | 0.940 | 0.824 | 55.76 | 55.76 | 55.76 | 90.00 | 90.00 | 22.86 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | BASEMENT_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_SOUTH_CFACTOR | 0.940 | 0.824 | 211.13 | 211.13 | 211.13 | 180.00 | 90.00 | 86.56 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BASEMENT_WALL_WEST | Wall | CTF - ConductionTransferFunction | BASEMENT_WALL_WEST_CFACTOR | 0.940 | 0.824 | 55.76 | 55.76 | 55.76 | 270.00 | 90.00 | 22.86 | 2.44 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | BASEMENT_FLOOR | Floor | CTF - ConductionTransferFunction | BASEMENT_FLOOR | 2.705 | 1.632 | 1978.83 | 1978.83 | 1978.83 | 0.00 | 180.00 | 86.56 | 22.86 | 0.00 | BASEMENT_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | BASEMENT_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 67.07 | 67.07 | 67.07 | 180.00 | 0.00 | 11.58 | 5.79 | 0.00 | RETAIL_1_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | BASEMENT_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 77.67 | 77.67 | 77.67 | 180.00 | 0.00 | 11.58 | 6.71 | 0.00 | RETAIL_2_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
8 | BASEMENT_CEILING_3 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 164.24 | 164.24 | 164.24 | 180.00 | 0.00 | 15.85 | 10.36 | 0.00 | MECH_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
9 | BASEMENT_CEILING_4 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 94.76 | 94.76 | 94.76 | 180.00 | 0.00 | 9.14 | 10.36 | 0.00 | STORAGE_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
10 | BASEMENT_CEILING_5 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 78.04 | 78.04 | 78.04 | 180.00 | 0.00 | 4.57 | 17.07 | 0.00 | LAUNDRY_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
11 | BASEMENT_CEILING_6 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 188.86 | 188.86 | 188.86 | 180.00 | 0.00 | 32.61 | 5.79 | 0.00 | CAFE_FLR_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
12 | BASEMENT_CEILING_7 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 1088.56 | 1088.56 | 1088.56 | 180.00 | 0.00 | 32.99 | 32.99 | 0.00 | LOBBY_FLR_1_FLOOR_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
13 | BASEMENT_CEILING_8 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 219.63 | 219.63 | 219.63 | 90.00 | 0.00 | 14.82 | 14.82 | 0.00 | LOBBY_FLR_1_FLOOR_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
14 | BASEMENT_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3957.66 | 3957.66 | 3957.66 | 0.00 | 90.00 | 3957.66 | 1.00 | 0.00 | BASEMENT_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | RETAIL_1_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 22.59 | 45.89 | 22.59 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | Window | RETAIL_1_FLR_1_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 23.30 | 23.30 | 23.30 | 180.00 | 90.00 | 10.92 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
17 | RETAIL_1_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | RETAIL_1_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 0.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | RETAIL_1_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | RETAIL_1_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 67.07 | 67.07 | 67.07 | 0.00 | 180.00 | 11.58 | 5.79 | 0.00 | BASEMENT_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
21 | RETAIL_1_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 67.07 | 67.07 | 67.07 | 180.00 | 0.00 | 11.58 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 7.62E-002 | 0.92 | 4 | ||
22 | RETAIL_1_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 134.14 | 134.14 | 134.14 | 0.00 | 90.00 | 134.14 | 1.00 | 0.00 | RETAIL_1_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
23 | RETAIL_2_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 24.62 | 26.57 | 24.62 | 270.00 | 90.00 | 6.71 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | RETAIL_2_FLR_1_WALL_WEST_DOOR | Door | RETAIL_2_FLR_1_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
25 | RETAIL_2_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_1_FLR_1_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
26 | RETAIL_2_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 0.00 | 90.00 | 11.58 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
27 | RETAIL_2_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.57 | 26.57 | 26.57 | 90.00 | 90.00 | 6.71 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | RETAIL_2_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 77.67 | 77.67 | 77.67 | 0.00 | 180.00 | 11.58 | 6.71 | 0.00 | BASEMENT_CEILING_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
29 | RETAIL_2_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 77.67 | 77.67 | 77.67 | 180.00 | 0.00 | 11.58 | 6.71 | 0.00 | RETAIL_2_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | RETAIL_2_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 155.34 | 155.34 | 155.34 | 0.00 | 90.00 | 155.34 | 1.00 | 0.00 | RETAIL_2_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
31 | MECH_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 62.80 | 62.80 | 62.80 | 0.00 | 90.00 | 15.85 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | MECH_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | MECH_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 62.80 | 62.80 | 62.80 | 180.00 | 90.00 | 15.85 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | MECH_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | MECH_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 164.24 | 164.24 | 164.24 | 0.00 | 180.00 | 15.85 | 10.36 | 0.00 | BASEMENT_CEILING_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | MECH_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 164.24 | 164.24 | 164.24 | 180.00 | 0.00 | 15.85 | 10.36 | 0.00 | MECH_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | MECH_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 328.49 | 328.49 | 328.49 | 0.00 | 90.00 | 328.49 | 1.00 | 0.00 | MECH_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | STORAGE_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 28.80 | 36.23 | 28.80 | 0.00 | 90.00 | 9.14 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | Door | STORAGE_FLR_1_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
40 | STORAGE_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_4_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
41 | STORAGE_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 36.23 | 36.23 | 36.23 | 180.00 | 90.00 | 9.14 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_4_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
42 | STORAGE_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | MECH_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | STORAGE_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 94.76 | 94.76 | 94.76 | 0.00 | 180.00 | 9.14 | 10.36 | 0.00 | BASEMENT_CEILING_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
44 | STORAGE_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 94.76 | 94.76 | 94.76 | 180.00 | 0.00 | 9.14 | 10.36 | 0.00 | STORAGE_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | STORAGE_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 189.52 | 189.52 | 189.52 | 0.00 | 90.00 | 189.52 | 1.00 | 0.00 | STORAGE_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
46 | LAUNDRY_FLR_1_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 18.12 | 18.12 | 18.12 | 0.00 | 90.00 | 4.57 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | LAUNDRY_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 65.68 | 67.63 | 65.68 | 90.00 | 90.00 | 17.07 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | LAUNDRY_FLR_1_WALL_EAST_DOOR | Door | LAUNDRY_FLR_1_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
49 | LAUNDRY_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.12 | 18.12 | 18.12 | 180.00 | 90.00 | 4.57 | 3.96 | 0.00 | CAFE_FLR_1_WALL_2_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | LAUNDRY_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 67.63 | 67.63 | 67.63 | 270.00 | 90.00 | 17.07 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | LAUNDRY_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 78.04 | 78.04 | 78.04 | 0.00 | 180.00 | 4.57 | 17.07 | 0.00 | BASEMENT_CEILING_5 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
52 | LAUNDRY_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 78.04 | 78.04 | 78.04 | 180.00 | 0.00 | 4.57 | 17.07 | 0.00 | LAUNDRY_FLR_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
53 | LAUNDRY_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 156.08 | 156.08 | 156.08 | 0.00 | 90.00 | 156.08 | 1.00 | 0.00 | LAUNDRY_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
54 | CAFE_FLR_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 21.00 | 22.95 | 21.00 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CAFE_FLR_1_WALL_EAST_DOOR | Door | CAFE_FLR_1_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | CAFE_FLR_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 63.61 | 129.23 | 63.61 | 180.00 | 90.00 | 32.61 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CAFE_FLR_1_WALL_SOUTH_WINDOW | Window | CAFE_FLR_1_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 65.62 | 65.62 | 65.62 | 180.00 | 90.00 | 30.75 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
58 | CAFE_FLR_1_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.11 | 111.11 | 111.11 | 0.00 | 90.00 | 28.04 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_3_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | CAFE_FLR_1_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.12 | 18.12 | 18.12 | 0.00 | 90.00 | 4.57 | 3.96 | 0.00 | LAUNDRY_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | CAFE_FLR_1_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | LOBBY_FLR_1_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | CAFE_FLR_1_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 188.86 | 188.86 | 188.86 | 0.00 | 180.00 | 32.61 | 5.79 | 0.00 | BASEMENT_CEILING_6 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
62 | CAFE_FLR_1_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 188.86 | 188.86 | 188.86 | 180.00 | 0.00 | 32.61 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 3.86E-002 | 0.96 | 4 | ||
63 | CAFE_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 377.72 | 377.72 | 377.72 | 0.00 | 90.00 | 377.72 | 1.00 | 0.00 | CAFE_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
64 | LOBBY_FLR_1_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 209.87 | 213.77 | 209.87 | 0.00 | 90.00 | 53.95 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | Door | LOBBY_FLR_1_WALL_1_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
66 | LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | Door | LOBBY_FLR_1_WALL_1_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
67 | LOBBY_FLR_1_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 12.08 | 12.08 | 12.08 | 0.00 | 90.00 | 3.05 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | LOBBY_FLR_1_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 82.63 | 167.88 | 82.63 | 180.00 | 90.00 | 42.37 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | LOBBY_FLR_1_WALL_SOUTH_WINDOW | Window | LOBBY_FLR_1_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 85.24 | 85.24 | 85.24 | 180.00 | 90.00 | 39.95 | 2.13 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LOBBY_FLR_1_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | LOBBY_FLR_1_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 45.89 | 45.89 | 45.89 | 180.00 | 90.00 | 11.58 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | LOBBY_FLR_1_WALL_3_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.11 | 111.11 | 111.11 | 180.00 | 90.00 | 28.04 | 3.96 | 0.00 | CAFE_FLR_1_WALL_1_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | LOBBY_FLR_1_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 270.00 | 90.00 | 5.79 | 3.96 | 0.00 | RETAIL_1_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
74 | LOBBY_FLR_1_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.57 | 26.57 | 26.57 | 270.00 | 90.00 | 6.71 | 3.96 | 0.00 | RETAIL_2_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
75 | LOBBY_FLR_1_WALL_4_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 270.00 | 90.00 | 10.36 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | LOBBY_FLR_1_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 62.80 | 62.80 | 62.80 | 0.00 | 90.00 | 15.85 | 3.96 | 0.00 | MECH_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | LOBBY_FLR_1_WALL_4_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 36.23 | 36.23 | 36.23 | 0.00 | 90.00 | 9.14 | 3.96 | 0.00 | STORAGE_FLR_1_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
78 | LOBBY_FLR_1_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 41.06 | 41.06 | 41.06 | 90.00 | 90.00 | 10.36 | 3.96 | 0.00 | MECH_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | LOBBY_FLR_1_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 22.95 | 22.95 | 22.95 | 90.00 | 90.00 | 5.79 | 3.96 | 0.00 | CAFE_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | LOBBY_FLR_1_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 67.63 | 67.63 | 67.63 | 90.00 | 90.00 | 17.07 | 3.96 | 0.00 | LAUNDRY_FLR_1_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | LOBBY_FLR_1_FLOOR_1 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 1088.56 | 1088.56 | 1088.56 | 180.00 | 180.00 | 32.99 | 32.99 | 0.00 | BASEMENT_CEILING_7 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
82 | LOBBY_FLR_1_FLOOR_2 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 219.63 | 219.63 | 219.63 | 90.00 | 180.00 | 14.82 | 14.82 | 0.00 | BASEMENT_CEILING_8 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
83 | LOBBY_FLR_1_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 1062.83 | 1062.83 | 1062.83 | 270.00 | 0.00 | 32.60 | 32.60 | 0.00 | LOBBY_FLR_1_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 10 | ||
84 | LOBBY_FLR_1_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 245.35 | 245.35 | 245.35 | 180.00 | 0.00 | 42.37 | 5.79 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.22E-003 | 1.00 | 4 | ||
85 | LOBBY_FLR_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 2616.37 | 2616.37 | 2616.37 | 0.00 | 90.00 | 2616.37 | 1.00 | 0.00 | LOBBY_FLR_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | ROOM_1_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | ROOM_1_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_1_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | ROOM_1_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | ROOM_1_FLR_3_WALL_WEST_WINDOW | Window | ROOM_1_FLR_3_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | ROOM_1_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_2_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | ROOM_1_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | ROOM_1_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
93 | ROOM_1_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
94 | ROOM_1_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_1_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
95 | ROOM_2_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
96 | ROOM_2_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_2_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
97 | ROOM_2_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 17.43 | 26.01 | 17.43 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | ROOM_2_FLR_3_WALL_WEST_WINDOW | Window | ROOM_2_FLR_3_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 8.58 | 8.58 | 8.58 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | ROOM_2_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_4_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | ROOM_2_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_1_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | ROOM_2_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | ROOM_2_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | ROOM_2_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_2_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | ROOM_3_MULT19_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 7.47 | 11.15 | 7.47 | 180.00 | 90.00 | 3.66 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_3_MULT19_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 3.68 | 3.68 | 3.68 | 180.00 | 90.00 | 3.02 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | ROOM_3_MULT19_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 0.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
107 | ROOM_3_MULT19_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
108 | ROOM_3_MULT19_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT19_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | ROOM_3_MULT19_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.52 | 24.52 | 24.52 | 0.00 | 180.00 | 3.66 | 6.71 | 0.00 | ROOM_3_MULT19_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
110 | ROOM_3_MULT19_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 24.52 | 24.52 | 24.52 | 180.00 | 0.00 | 3.66 | 6.71 | 0.00 | ROOM_3_MULT19_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
111 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.05 | 49.05 | 49.05 | 0.00 | 90.00 | 49.05 | 1.00 | 0.00 | ROOM_3_MULT19_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
112 | ROOM_4_MULT19_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 7.47 | 11.15 | 7.47 | 0.00 | 90.00 | 3.66 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_4_MULT19_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 3.68 | 3.68 | 3.68 | 0.00 | 90.00 | 3.02 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
114 | ROOM_4_MULT19_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 180.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | ROOM_4_MULT19_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_4_MULT19_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
117 | ROOM_4_MULT19_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.53 | 24.53 | 24.53 | 0.00 | 180.00 | 3.66 | 6.71 | 0.00 | ROOM_4_MULT19_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
118 | ROOM_4_MULT19_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 24.53 | 24.53 | 24.53 | 180.00 | 0.00 | 3.66 | 6.71 | 0.00 | ROOM_4_MULT19_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
119 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.06 | 49.06 | 49.06 | 0.00 | 90.00 | 49.06 | 1.00 | 0.00 | ROOM_4_MULT19_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
120 | ROOM_5_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 17.43 | 26.01 | 17.43 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | ROOM_5_FLR_3_WALL_EAST_WINDOW | Window | ROOM_5_FLR_3_WALL_EAST | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 8.58 | 8.58 | 8.58 | 90.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
122 | ROOM_5_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.34 | 13.94 | 9.34 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | ROOM_5_FLR_3_WALL_SOUTH_WINDOW | Window | ROOM_5_FLR_3_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
124 | ROOM_5_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_6_FLR_3_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
125 | ROOM_5_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
126 | ROOM_5_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_5_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
127 | ROOM_5_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ROOM_5_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
128 | ROOM_5_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_5_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
129 | ROOM_6_FLR_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.34 | 13.94 | 9.34 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
130 | ROOM_6_FLR_3_WALL_NORTH_WINDOW | Window | ROOM_6_FLR_3_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
131 | ROOM_6_FLR_3_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 17.43 | 26.01 | 17.43 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | ROOM_6_FLR_3_WALL_EAST_WINDOW | Window | ROOM_6_FLR_3_WALL_EAST | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 8.58 | 8.58 | 8.58 | 90.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
133 | ROOM_6_FLR_3_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_5_FLR_3_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
134 | ROOM_6_FLR_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_4_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
135 | ROOM_6_FLR_3_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_6_FLR_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
136 | ROOM_6_FLR_3_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ROOM_6_FLR_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
137 | ROOM_6_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_6_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
138 | CORRIDOR_FLR_3_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 11.83 | 17.65 | 11.83 | 0.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_1_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 5.82 | 5.82 | 5.82 | 0.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
140 | CORRIDOR_FLR_3_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 4.35 | 6.50 | 4.35 | 0.00 | 90.00 | 2.13 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_2_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.15 | 2.15 | 2.15 | 0.00 | 90.00 | 1.76 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
142 | CORRIDOR_FLR_3_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 4.36 | 6.50 | 4.36 | 180.00 | 90.00 | 2.13 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
143 | CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 2.15 | 2.15 | 2.15 | 180.00 | 90.00 | 1.76 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
144 | CORRIDOR_FLR_3_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 11.83 | 17.65 | 11.83 | 180.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | Window | CORRIDOR_FLR_3_WALL_2_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 5.82 | 5.82 | 5.82 | 180.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | CORRIDOR_FLR_3_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 211.82 | 211.82 | 211.82 | 0.00 | 90.00 | 69.50 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | CORRIDOR_FLR_3_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | CORRIDOR_FLR_3_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | CORRIDOR_FLR_3_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_5_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
150 | CORRIDOR_FLR_3_WALL_4_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_6_FLR_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
151 | CORRIDOR_FLR_3_WALL_3_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 211.82 | 211.82 | 211.82 | 180.00 | 90.00 | 69.49 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_3_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
152 | CORRIDOR_FLR_3_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | CORRIDOR_FLR_3_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_3_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
154 | CORRIDOR_FLR_3_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_1_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | CORRIDOR_FLR_3_WALL_4_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_2_FLR_3_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | CORRIDOR_FLR_3_FLOOR_1 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 74.32 | 74.32 | 74.32 | 180.00 | 180.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_FLOOR_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
157 | CORRIDOR_FLR_3_FLOOR_2 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 240.77 | 240.77 | 240.77 | 270.00 | 180.00 | 3.66 | 65.84 | 0.00 | CORRIDOR_FLR_3_FLOOR_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | CORRIDOR_FLR_3_FLOOR_3 | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 74.32 | 74.32 | 74.32 | 90.00 | 180.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_FLOOR_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
159 | CORRIDOR_FLR_3_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 74.32 | 74.32 | 74.32 | 90.00 | 0.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_CEILING_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
160 | CORRIDOR_FLR_3_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 240.77 | 240.77 | 240.77 | 90.00 | 0.00 | 3.66 | 65.84 | 0.00 | CORRIDOR_FLR_3_CEILING_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
161 | CORRIDOR_FLR_3_CEILING_3 | Roof | CTF - ConductionTransferFunction | NONRES_FLOOR_CEILING | 0.196 | 0.189 | 74.32 | 74.32 | 74.32 | 90.00 | 0.00 | 8.62 | 8.62 | 0.00 | CORRIDOR_FLR_3_CEILING_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
162 | CORRIDOR_FLR_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 778.81 | 778.81 | 778.81 | 0.00 | 90.00 | 778.81 | 1.00 | 0.00 | CORRIDOR_FLR_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
163 | ROOM_1_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.33 | 13.94 | 9.33 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | ROOM_1_FLR_6_WALL_SOUTH_WINDOW | Window | ROOM_1_FLR_6_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
165 | ROOM_1_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 17.42 | 26.01 | 17.42 | 270.00 | 90.00 | 8.54 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
166 | ROOM_1_FLR_6_WALL_WEST_WINDOW | Window | ROOM_1_FLR_6_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 8.59 | 8.59 | 8.59 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
167 | ROOM_1_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_2_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
168 | ROOM_1_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.54 | 3.05 | 0.00 | ROOM_1_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
169 | ROOM_1_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.54 | 0.00 | ROOM_1_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
170 | ROOM_1_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.54 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
171 | ROOM_1_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.04 | 78.04 | 78.04 | 0.00 | 90.00 | 78.04 | 1.00 | 0.00 | ROOM_1_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
172 | ROOM_2_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.33 | 13.94 | 9.33 | 0.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
173 | ROOM_2_FLR_6_WALL_NORTH_WINDOW | Window | ROOM_2_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
174 | ROOM_2_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 17.42 | 26.01 | 17.42 | 270.00 | 90.00 | 8.53 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
175 | ROOM_2_FLR_6_WALL_WEST_WINDOW | Window | ROOM_2_FLR_6_WALL_WEST | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 8.59 | 8.59 | 8.59 | 270.00 | 90.00 | 7.04 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
176 | ROOM_2_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 26.01 | 26.01 | 26.01 | 90.00 | 90.00 | 8.53 | 3.05 | 0.00 | ROOM_2_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
177 | ROOM_2_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 13.94 | 13.94 | 13.94 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ROOM_1_FLR_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
178 | ROOM_2_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 39.02 | 39.02 | 39.02 | 0.00 | 180.00 | 4.57 | 8.53 | 0.00 | ROOM_2_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
179 | ROOM_2_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 39.02 | 39.02 | 39.02 | 180.00 | 0.00 | 4.57 | 8.53 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
180 | ROOM_2_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 78.03 | 78.03 | 78.03 | 0.00 | 90.00 | 78.03 | 1.00 | 0.00 | ROOM_2_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
181 | ROOM_3_MULT9_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 13.69 | 20.44 | 13.69 | 180.00 | 90.00 | 6.71 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
182 | ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | Window | ROOM_3_MULT9_FLR_6_WALL_SOUTH | Window5 Detailed Fenestration | RESWINDOW_U_0.47_SHGC_0.25 | N/A | 2.672 | No | 6.75 | 6.75 | 6.75 | 180.00 | 90.00 | 5.53 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
183 | ROOM_3_MULT9_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 0.00 | 90.00 | 6.71 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
184 | ROOM_3_MULT9_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 90.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
185 | ROOM_3_MULT9_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 270.00 | 90.00 | 3.66 | 3.05 | 0.00 | ROOM_3_MULT9_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
186 | ROOM_3_MULT9_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 24.53 | 24.53 | 24.53 | 0.00 | 180.00 | 6.71 | 3.66 | 0.00 | ROOM_3_MULT9_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
187 | ROOM_3_MULT9_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 24.53 | 24.53 | 24.53 | 180.00 | 0.00 | 6.71 | 3.66 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
188 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 49.06 | 49.06 | 49.06 | 0.00 | 90.00 | 49.06 | 1.00 | 0.00 | ROOM_3_MULT9_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
189 | BANQUET_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 65.34 | 97.55 | 65.34 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
190 | BANQUET_FLR_6_WALL_NORTH_WINDOW | Window | BANQUET_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 32.21 | 32.21 | 32.21 | 0.00 | 90.00 | 26.40 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
191 | BANQUET_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
192 | BANQUET_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 180.00 | 90.00 | 32.00 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
193 | BANQUET_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
194 | BANQUET_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 331.66 | 331.66 | 331.66 | 0.00 | 180.00 | 32.00 | 10.36 | 0.00 | BANQUET_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
195 | BANQUET_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 331.66 | 331.66 | 331.66 | 180.00 | 0.00 | 32.00 | 10.36 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
196 | BANQUET_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 663.31 | 663.31 | 663.31 | 0.00 | 90.00 | 663.31 | 1.00 | 0.00 | BANQUET_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
197 | DINING_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 65.34 | 97.55 | 65.34 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
198 | DINING_FLR_6_WALL_NORTH_WINDOW | Window | DINING_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 32.21 | 32.21 | 32.21 | 0.00 | 90.00 | 26.40 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
199 | DINING_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
200 | DINING_FLR_6_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 180.00 | 90.00 | 32.00 | 3.05 | 0.00 | DINING_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
201 | DINING_FLR_6_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_2_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
202 | DINING_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 331.66 | 331.66 | 331.66 | 0.00 | 180.00 | 32.00 | 10.36 | 0.00 | DINING_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
203 | DINING_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 331.66 | 331.66 | 331.66 | 180.00 | 0.00 | 32.00 | 10.36 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
204 | DINING_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 663.31 | 663.31 | 663.31 | 0.00 | 90.00 | 663.31 | 1.00 | 0.00 | DINING_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
205 | KITCHEN_FLR_6_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 16.76 | 21.37 | 16.76 | 0.00 | 90.00 | 7.01 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
206 | KITCHEN_FLR_6_WALL_NORTH_WINDOW | Window | KITCHEN_FLR_6_WALL_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 4.60 | 4.60 | 4.60 | 0.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
207 | KITCHEN_FLR_6_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 34.85 | 52.03 | 34.85 | 90.00 | 90.00 | 17.07 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
208 | KITCHEN_FLR_6_WALL_EAST_WINDOW | Window | KITCHEN_FLR_6_WALL_EAST | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 17.18 | 17.18 | 17.18 | 90.00 | 90.00 | 14.08 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
209 | KITCHEN_FLR_6_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 9.33 | 13.94 | 9.33 | 180.00 | 90.00 | 4.57 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
210 | KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | Window | KITCHEN_FLR_6_WALL_1_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 4.60 | 4.60 | 4.60 | 180.00 | 90.00 | 3.77 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
211 | KITCHEN_FLR_6_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 7.43 | 7.43 | 7.43 | 180.00 | 90.00 | 2.44 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_2_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
212 | KITCHEN_FLR_6_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 270.00 | 90.00 | 6.71 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_3_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
213 | KITCHEN_FLR_6_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | DINING_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
214 | KITCHEN_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 103.30 | 103.30 | 103.30 | 180.00 | 180.00 | 10.16 | 10.16 | 0.00 | KITCHEN_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 6 | ||
215 | KITCHEN_FLR_6_CEILING | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 103.30 | 103.30 | 103.30 | 270.00 | 0.00 | 10.16 | 10.16 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
216 | KITCHEN_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 206.61 | 206.61 | 206.61 | 0.00 | 90.00 | 206.61 | 1.00 | 0.00 | KITCHEN_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
217 | CORRIDOR_FLR_6_WALL_1_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 11.82 | 17.65 | 11.82 | 0.00 | 90.00 | 5.79 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
218 | CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_1_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 5.83 | 5.83 | 5.83 | 0.00 | 90.00 | 4.78 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
219 | CORRIDOR_FLR_6_WALL_2_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 10.58 | 15.79 | 10.58 | 0.00 | 90.00 | 5.18 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
220 | CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_2_NORTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 5.21 | 5.21 | 5.21 | 0.00 | 90.00 | 4.27 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
221 | CORRIDOR_FLR_6_WALL_2_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 34.85 | 52.03 | 34.85 | 180.00 | 90.00 | 17.07 | 3.05 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
222 | CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | Window | CORRIDOR_FLR_6_WALL_2_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 17.18 | 17.18 | 17.18 | 180.00 | 90.00 | 14.08 | 1.22 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
223 | CORRIDOR_FLR_6_WALL_3_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 97.55 | 97.55 | 97.55 | 0.00 | 90.00 | 32.00 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
224 | CORRIDOR_FLR_6_WALL_4_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 104.98 | 104.98 | 104.98 | 0.00 | 90.00 | 34.44 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_4_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
225 | CORRIDOR_FLR_6_WALL_1_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 183.95 | 183.95 | 183.95 | 180.00 | 90.00 | 60.35 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
226 | CORRIDOR_FLR_6_WALL_1_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 11.15 | 11.15 | 11.15 | 270.00 | 90.00 | 3.66 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
227 | CORRIDOR_FLR_6_WALL_2_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 40.88 | 40.88 | 40.88 | 270.00 | 90.00 | 13.41 | 3.05 | 0.00 | CORRIDOR_FLR_6_WALL_2_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
228 | CORRIDOR_FLR_6_WALL_3_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 270.00 | 90.00 | 10.36 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
229 | CORRIDOR_FLR_6_WALL_1_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | BANQUET_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
230 | CORRIDOR_FLR_6_WALL_2_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 31.59 | 31.59 | 31.59 | 90.00 | 90.00 | 10.36 | 3.05 | 0.00 | DINING_FLR_6_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
231 | CORRIDOR_FLR_6_WALL_3_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 20.44 | 20.44 | 20.44 | 90.00 | 90.00 | 6.71 | 3.05 | 0.00 | KITCHEN_FLR_6_WALL_1_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
232 | CORRIDOR_FLR_6_FLOOR | Floor | CTF - ConductionTransferFunction | NONRES_FLOOR | 0.196 | 0.187 | 412.12 | 412.12 | 412.12 | 180.00 | 180.00 | 20.30 | 20.30 | 0.00 | CORRIDOR_FLR_6_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 12 | ||
233 | CORRIDOR_FLR_6_CEILING_1 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 244.71 | 244.71 | 244.71 | 90.00 | 0.00 | 15.64 | 15.64 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
234 | CORRIDOR_FLR_6_CEILING_2 | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 167.42 | 167.42 | 167.42 | 270.00 | 0.00 | 12.94 | 12.94 | 0.00 | ExternalEnvironment | DOE-2 | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 6 | ||
235 | CORRIDOR_FLR_6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 824.25 | 824.25 | 824.25 | 0.00 | 90.00 | 824.25 | 1.00 | 0.00 | CORRIDOR_FLR_6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 7 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BASEMENT | RunPeriod: RUNPERIOD 1 | 2.2458996845E-002 | 2.4109149296E-002 | Pass | Pass | 6.0222215471E-003 | 6.2460990416E-003 | Pass | Pass |
2 | RETAIL_1_FLR_1 | RunPeriod: RUNPERIOD 1 | 9.6313676713E-003 | 3.1163107964E-002 | Pass | Pass | 7.2225725529E-002 | 8.2651121238E-002 | Pass | Pass |
3 | RETAIL_2_FLR_1 | RunPeriod: RUNPERIOD 1 | 3.0160862380E-002 | 3.3972198735E-002 | Pass | Pass | 9.1562749084E-003 | 9.8554532397E-003 | Pass | Pass |
4 | MECH_FLR_1 | RunPeriod: RUNPERIOD 1 | 8.7437648404E-003 | 1.6858410477E-002 | Pass | Pass | 1.6175956759E-002 | 3.3473587163E-002 | Pass | Pass |
5 | STORAGE_FLR_1 | RunPeriod: RUNPERIOD 1 | 1.4358302284E-003 | 3.7033542825E-003 | Pass | Pass | 2.5691923683E-002 | 3.3466291039E-002 | Pass | Pass |
6 | LAUNDRY_FLR_1 | RunPeriod: RUNPERIOD 1 | 8.0483264558E-002 | 0.2147460567 | Pass | Pass | 1.8257113487E-002 | 4.9320178598E-002 | Pass | Pass |
7 | CAFE_FLR_1 | RunPeriod: RUNPERIOD 1 | 6.0509466395E-002 | 7.8789327785E-002 | Pass | Pass | 1.8114782055E-002 | 2.6783772263E-002 | Pass | Pass |
8 | LOBBY_FLR_1 | RunPeriod: RUNPERIOD 1 | 4.5273269598E-002 | 4.7600048757E-002 | Pass | Pass | 8.1570723649E-003 | 8.5098257684E-003 | Pass | Pass |
9 | ROOM_1_FLR_3 | RunPeriod: RUNPERIOD 1 | 3.0016552853E-002 | 7.8994854694E-002 | Pass | Pass | 0.2124189324 | 0.6259978270 | Pass | Pass |
10 | ROOM_2_FLR_3 | RunPeriod: RUNPERIOD 1 | 4.0330170672E-002 | 0.1234785732 | Pass | Pass | 0.1275351397 | 0.4358222856 | Pass | Pass |
11 | ROOM_3_MULT19_FLR_3 | RunPeriod: RUNPERIOD 1 | 4.7638072103E-002 | 5.8617252290E-002 | Pass | Pass | 7.5483187522E-003 | 7.3038370926E-003 | Pass | Pass |
12 | ROOM_4_MULT19_FLR_3 | RunPeriod: RUNPERIOD 1 | 1.6425775966E-002 | 6.8039620115E-002 | Pass | Pass | 0.1064406175 | 0.2977707768 | Pass | Pass |
13 | ROOM_5_FLR_3 | RunPeriod: RUNPERIOD 1 | 4.4052483380E-002 | 0.1633406478 | Pass | Pass | 0.4589355669 | 2.9280950978 | Pass | Pass |
14 | ROOM_6_FLR_3 | RunPeriod: RUNPERIOD 1 | 4.0868827538E-002 | 0.1373696256 | Pass | Pass | 0.3182906722 | 0.9632969556 | Pass | Pass |
15 | CORRIDOR_FLR_3 | RunPeriod: RUNPERIOD 1 | 5.0266633373E-004 | 1.0241061553E-003 | Pass | Pass | 2.1599422506 | 20.7715165344 | Pass | Pass |
16 | ROOM_1_FLR_6 | RunPeriod: RUNPERIOD 1 | 3.9320091662E-002 | 0.1142438861 | Pass | Pass | 0.2773356428 | 2.1685742866 | Pass | Pass |
17 | ROOM_2_FLR_6 | RunPeriod: RUNPERIOD 1 | 5.5406597500E-002 | 0.1741014433 | Pass | Pass | 0.6441692340 | 5.7884052376 | Pass | Pass |
18 | ROOM_3_MULT9_FLR_6 | RunPeriod: RUNPERIOD 1 | 4.2808433490E-002 | 0.1588474604 | Pass | Pass | 0.3864692715 | 1.8387045126 | Pass | Pass |
19 | BANQUET_FLR_6 | RunPeriod: RUNPERIOD 1 | 4.6601270637E-002 | 8.0751141577E-002 | Pass | Pass | 9.5111118677E-003 | 2.3989761769E-002 | Pass | Pass |
20 | DINING_FLR_6 | RunPeriod: RUNPERIOD 1 | 3.7691231453E-002 | 6.7833675788E-002 | Pass | Pass | 1.0956910773E-002 | 3.0208327498E-002 | Pass | Pass |
21 | KITCHEN_FLR_6 | RunPeriod: RUNPERIOD 1 | 5.6561099605E-002 | 0.1245280395 | Pass | Pass | 1.9522831543E-002 | 3.4027615619E-002 | Pass | Pass |
22 | CORRIDOR_FLR_6 | RunPeriod: RUNPERIOD 1 | 1.8923557410E-003 | 4.4380940973E-003 | Pass | Pass | 3.8574375191E-002 | 3.8361194063E-002 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00 | 3.80 | Wetbulb [C] | 3.00 | 120.00 |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 31.30 | 8.90 | 18.40 | Wetbulb [C] | 4.10 | 280.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
RETAIL_1_FLR_1_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 45.89 | 22.59 | 180.00 | 90.00 | S |
RETAIL_1_FLR_1_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 22.95 | 22.95 | 270.00 | 90.00 | W |
RETAIL_1_FLR_1_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 67.07 | 67.07 | 180.00 | 0.00 | |
RETAIL_2_FLR_1_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 26.57 | 24.62 | 270.00 | 90.00 | W |
MECH_FLR_1_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 62.80 | 62.80 | 0.00 | 90.00 | N |
STORAGE_FLR_1_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 36.23 | 28.80 | 0.00 | 90.00 | N |
LAUNDRY_FLR_1_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 18.12 | 18.12 | 0.00 | 90.00 | N |
LAUNDRY_FLR_1_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 67.63 | 65.68 | 90.00 | 90.00 | E |
CAFE_FLR_1_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 22.95 | 21.00 | 90.00 | 90.00 | E |
CAFE_FLR_1_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 129.23 | 63.61 | 180.00 | 90.00 | S |
CAFE_FLR_1_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 188.86 | 188.86 | 180.00 | 0.00 | |
LOBBY_FLR_1_WALL_1_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 213.77 | 209.87 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_2_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 12.08 | 12.08 | 0.00 | 90.00 | N |
LOBBY_FLR_1_WALL_1_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 167.88 | 82.63 | 180.00 | 90.00 | S |
LOBBY_FLR_1_WALL_1_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 41.06 | 41.06 | 270.00 | 90.00 | W |
LOBBY_FLR_1_CEILING_2 | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 245.35 | 245.35 | 180.00 | 0.00 | |
ROOM_1_FLR_3_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 55.74 | 37.35 | 180.00 | 90.00 | S |
ROOM_1_FLR_3_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 104.06 | 69.73 | 270.00 | 90.00 | W |
ROOM_2_FLR_3_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 55.74 | 37.35 | 0.00 | 90.00 | N |
ROOM_2_FLR_3_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 104.05 | 69.71 | 270.00 | 90.00 | W |
ROOM_3_MULT19_FLR_3_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 847.14 | 567.63 | 180.00 | 90.00 | S |
ROOM_4_MULT19_FLR_3_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 847.37 | 567.77 | 0.00 | 90.00 | N |
ROOM_5_FLR_3_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 104.06 | 69.73 | 90.00 | 90.00 | E |
ROOM_5_FLR_3_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 55.74 | 37.35 | 180.00 | 90.00 | S |
ROOM_6_FLR_3_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 55.74 | 37.35 | 0.00 | 90.00 | N |
ROOM_6_FLR_3_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 104.05 | 69.71 | 90.00 | 90.00 | E |
CORRIDOR_FLR_3_WALL_1_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 70.60 | 47.31 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_2_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 26.01 | 17.42 | 0.00 | 90.00 | N |
CORRIDOR_FLR_3_WALL_1_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 26.02 | 17.44 | 180.00 | 90.00 | S |
CORRIDOR_FLR_3_WALL_2_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 70.60 | 47.31 | 180.00 | 90.00 | S |
ROOM_1_FLR_6_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 13.94 | 9.33 | 180.00 | 90.00 | S |
ROOM_1_FLR_6_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 26.01 | 17.42 | 270.00 | 90.00 | W |
ROOM_1_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 39.02 | 39.02 | 180.00 | 0.00 | |
ROOM_2_FLR_6_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 13.94 | 9.33 | 0.00 | 90.00 | N |
ROOM_2_FLR_6_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 26.01 | 17.42 | 270.00 | 90.00 | W |
ROOM_2_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 39.02 | 39.02 | 180.00 | 0.00 | |
ROOM_3_MULT9_FLR_6_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 183.96 | 123.22 | 180.00 | 90.00 | S |
ROOM_3_MULT9_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 220.77 | 220.77 | 180.00 | 0.00 | |
BANQUET_FLR_6_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 97.55 | 65.34 | 0.00 | 90.00 | N |
BANQUET_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 331.66 | 331.66 | 180.00 | 0.00 | |
DINING_FLR_6_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 97.55 | 65.34 | 0.00 | 90.00 | N |
DINING_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 331.66 | 331.66 | 180.00 | 0.00 | |
KITCHEN_FLR_6_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 21.37 | 16.76 | 0.00 | 90.00 | N |
KITCHEN_FLR_6_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 52.03 | 34.85 | 90.00 | 90.00 | E |
KITCHEN_FLR_6_WALL_1_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 13.94 | 9.33 | 180.00 | 90.00 | S |
KITCHEN_FLR_6_CEILING | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 103.30 | 103.30 | 270.00 | 0.00 | |
CORRIDOR_FLR_6_WALL_1_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 17.65 | 11.82 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_2_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 15.79 | 10.58 | 0.00 | 90.00 | N |
CORRIDOR_FLR_6_WALL_2_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 52.03 | 34.85 | 180.00 | 90.00 | S |
CORRIDOR_FLR_6_CEILING_1 | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 244.71 | 244.71 | 90.00 | 0.00 | |
CORRIDOR_FLR_6_CEILING_2 | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 167.42 | 167.42 | 270.00 | 0.00 | |
BASEMENT_WALL_NORTH | BASEMENT_WALL_NORTH_CFACTOR | 1.00 | 0.940 | 211.13 | 211.13 | 0.00 | 90.00 | N | |
BASEMENT_WALL_EAST | BASEMENT_WALL_EAST_CFACTOR | 1.00 | 0.940 | 55.76 | 55.76 | 90.00 | 90.00 | E | |
BASEMENT_WALL_SOUTH | BASEMENT_WALL_SOUTH_CFACTOR | 1.00 | 0.940 | 211.13 | 211.13 | 180.00 | 90.00 | S | |
BASEMENT_WALL_WEST | BASEMENT_WALL_WEST_CFACTOR | 1.00 | 0.940 | 55.76 | 55.76 | 270.00 | 90.00 | W |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 23.30 | 0.00 | 0.00 | 23.30 | 23.30 | 2.615 | 0.252 | 0.251 | No | RETAIL_1_FLR_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
CAFE_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 65.62 | 0.00 | 0.00 | 65.62 | 65.62 | 2.615 | 0.252 | 0.251 | No | CAFE_FLR_1_WALL_SOUTH | 180.00 | 90.00 | S | ||
LOBBY_FLR_1_WALL_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 85.24 | 0.00 | 0.00 | 85.24 | 85.24 | 2.615 | 0.252 | 0.251 | No | LOBBY_FLR_1_WALL_1_SOUTH | 180.00 | 90.00 | S | ||
ROOM_1_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.39 | 2.672 | 0.252 | 0.251 | No | ROOM_1_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | ||
ROOM_1_FLR_3_WALL_WEST_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.33 | 2.672 | 0.252 | 0.251 | No | ROOM_1_FLR_3_WALL_WEST | 270.00 | 90.00 | W | ||
ROOM_2_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.39 | 2.672 | 0.252 | 0.251 | No | ROOM_2_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | ||
ROOM_2_FLR_3_WALL_WEST_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.33 | 2.672 | 0.252 | 0.251 | No | ROOM_2_FLR_3_WALL_WEST | 270.00 | 90.00 | W | ||
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 3.68 | 0.00 | 0.00 | 3.68 | 279.51 | 2.672 | 0.252 | 0.251 | No | ROOM_3_MULT19_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | ||
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 3.68 | 0.00 | 0.00 | 3.68 | 279.60 | 2.672 | 0.252 | 0.251 | No | ROOM_4_MULT19_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | ||
ROOM_5_FLR_3_WALL_EAST_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.33 | 2.672 | 0.252 | 0.251 | No | ROOM_5_FLR_3_WALL_EAST | 90.00 | 90.00 | E | ||
ROOM_5_FLR_3_WALL_SOUTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.39 | 2.672 | 0.252 | 0.251 | No | ROOM_5_FLR_3_WALL_SOUTH | 180.00 | 90.00 | S | ||
ROOM_6_FLR_3_WALL_NORTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 18.39 | 2.672 | 0.252 | 0.251 | No | ROOM_6_FLR_3_WALL_NORTH | 0.00 | 90.00 | N | ||
ROOM_6_FLR_3_WALL_EAST_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 8.58 | 0.00 | 0.00 | 8.58 | 34.33 | 2.672 | 0.252 | 0.251 | No | ROOM_6_FLR_3_WALL_EAST | 90.00 | 90.00 | E | ||
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 5.82 | 0.00 | 0.00 | 5.82 | 23.29 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_3_WALL_1_NORTH | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.15 | 0.00 | 0.00 | 2.15 | 8.59 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_3_WALL_2_NORTH | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 2.15 | 0.00 | 0.00 | 2.15 | 8.58 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_3_WALL_1_SOUTH | 180.00 | 90.00 | S | ||
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 5.82 | 0.00 | 0.00 | 5.82 | 23.29 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_3_WALL_2_SOUTH | 180.00 | 90.00 | S | ||
ROOM_1_FLR_6_WALL_SOUTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.672 | 0.252 | 0.251 | No | ROOM_1_FLR_6_WALL_SOUTH | 180.00 | 90.00 | S | ||
ROOM_1_FLR_6_WALL_WEST_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 8.59 | 0.00 | 0.00 | 8.59 | 8.59 | 2.672 | 0.252 | 0.251 | No | ROOM_1_FLR_6_WALL_WEST | 270.00 | 90.00 | W | ||
ROOM_2_FLR_6_WALL_NORTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.672 | 0.252 | 0.251 | No | ROOM_2_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | ||
ROOM_2_FLR_6_WALL_WEST_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 8.59 | 0.00 | 0.00 | 8.59 | 8.59 | 2.672 | 0.252 | 0.251 | No | ROOM_2_FLR_6_WALL_WEST | 270.00 | 90.00 | W | ||
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | RESWINDOW_U_0.47_SHGC_0.25 | 6.75 | 0.00 | 0.00 | 6.75 | 60.74 | 2.672 | 0.252 | 0.251 | No | ROOM_3_MULT9_FLR_6_WALL_SOUTH | 180.00 | 90.00 | S | ||
BANQUET_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 32.21 | 0.00 | 0.00 | 32.21 | 32.21 | 2.615 | 0.252 | 0.251 | No | BANQUET_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | ||
DINING_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 32.21 | 0.00 | 0.00 | 32.21 | 32.21 | 2.615 | 0.252 | 0.251 | No | DINING_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | ||
KITCHEN_FLR_6_WALL_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.615 | 0.252 | 0.251 | No | KITCHEN_FLR_6_WALL_NORTH | 0.00 | 90.00 | N | ||
KITCHEN_FLR_6_WALL_EAST_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 17.18 | 0.00 | 0.00 | 17.18 | 17.18 | 2.615 | 0.252 | 0.251 | No | KITCHEN_FLR_6_WALL_EAST | 90.00 | 90.00 | E | ||
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 4.60 | 0.00 | 0.00 | 4.60 | 4.60 | 2.615 | 0.252 | 0.251 | No | KITCHEN_FLR_6_WALL_1_SOUTH | 180.00 | 90.00 | S | ||
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 5.83 | 0.00 | 0.00 | 5.83 | 5.83 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_6_WALL_1_NORTH | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 5.21 | 0.00 | 0.00 | 5.21 | 5.21 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_6_WALL_2_NORTH | 0.00 | 90.00 | N | ||
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | NONRESWINDOW_U_0.46_SHGC_0.25 | 17.18 | 0.00 | 0.00 | 17.18 | 17.18 | 2.615 | 0.252 | 0.251 | No | CORRIDOR_FLR_6_WALL_2_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 1214.08 | 2.655 | 0.252 | 0.251 | ||||||||||||
North Total or Average | 432.93 | 2.657 | 0.252 | 0.251 | ||||||||||||
Non-North Total or Average | 781.15 | 2.654 | 0.252 | 0.251 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
RETAIL_2_FLR_1_WALL_WEST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | RETAIL_2_FLR_1_WALL_WEST |
STORAGE_FLR_1_WALL_NORTH_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | STORAGE_FLR_1_WALL_NORTH |
LAUNDRY_FLR_1_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LAUNDRY_FLR_1_WALL_EAST |
CAFE_FLR_1_WALL_EAST_DOOR | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CAFE_FLR_1_WALL_EAST |
LOBBY_FLR_1_WALL_1_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LOBBY_FLR_1_WALL_1_NORTH |
LOBBY_FLR_1_WALL_1_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | LOBBY_FLR_1_WALL_1_NORTH |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
RETAIL_1_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CAFE_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LOBBY_FLR_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_3_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_2_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
ROOM_5_FLR_3_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_6_FLR_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_6_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
ROOM_1_FLR_6_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_2_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
BANQUET_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BASEMENT_LIGHTS | BASEMENT | 8.4281 | 1978.83 | 16677.86 | LightsWired | BLDG_LIGHT_OFFICE_BSMT_SCH | 54.51 | 168.00 | 54.45 | 0.0000 | Y | 170.46 |
RETAIL_1_FLR_1_LIGHTS | RETAIL_1_FLR_1 | 12.2063 | 67.07 | 818.69 | LightsWired | BLDG_LIGHT_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 9.01 |
RETAIL_2_FLR_1_LIGHTS | RETAIL_2_FLR_1 | 12.2063 | 77.67 | 948.05 | LightsWired | BLDG_LIGHT_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 10.43 |
MECH_FLR_1_LIGHTS | MECH_FLR_1 | 9.2031 | 164.24 | 1511.55 | LightsWired | BLDG_LIGHT_MECHANIC_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 16.64 |
STORAGE_FLR_1_LIGHTS | STORAGE_FLR_1 | 6.1031 | 94.76 | 578.33 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 30.52 | 168.00 | 30.49 | 0.0000 | Y | 3.31 |
LAUNDRY_FLR_1_LIGHTS | LAUNDRY_FLR_1 | 5.8125 | 78.04 | 453.61 | LightsWired | BLDG_LIGHT_MISC_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 4.99 |
CAFE_FLR_1_LIGHTS | CAFE_FLR_1 | 10.3656 | 188.86 | 1957.68 | LightsWired | BLDG_LIGHT_MISC_SCH | 58.69 | 168.00 | 49.25 | 0.0000 | Y | 18.10 |
LOBBY_FLR_1_LIGHTS | LOBBY_FLR_1 | 10.2688 | 1308.19 | 13433.46 | LightsWired | BLDG_LIGHT_SCH | 58.69 | 168.00 | 57.00 | 0.0000 | Y | 143.73 |
ROOM_1_FLR_3_LIGHTS | ROOM_1_FLR_3 | 4.5531 | 156.09 | 710.69 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 5.69 |
ROOM_2_FLR_3_LIGHTS | ROOM_2_FLR_3 | 4.5531 | 156.07 | 710.61 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 5.69 |
ROOM_3_MULT19_FLR_3_LIGHTS | ROOM_3_MULT19_FLR_3 | 4.5531 | 1863.81 | 8486.19 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 67.92 |
ROOM_4_MULT19_FLR_3_LIGHTS | ROOM_4_MULT19_FLR_3 | 4.5531 | 1864.32 | 8488.51 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 67.94 |
ROOM_5_FLR_3_LIGHTS | ROOM_5_FLR_3 | 4.5531 | 156.09 | 710.69 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 5.69 |
ROOM_6_FLR_3_LIGHTS | ROOM_6_FLR_3 | 4.5531 | 156.07 | 710.61 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 5.69 |
CORRIDOR_FLR_3_LIGHTS | CORRIDOR_FLR_3 | 6.3938 | 1557.62 | 9959.04 | LightsWired | BLDG_LIGHT_CORRIDOR_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 109.60 |
ROOM_1_FLR_6_LIGHTS | ROOM_1_FLR_6 | 4.5531 | 39.02 | 177.67 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 1.42 |
ROOM_2_FLR_6_LIGHTS | ROOM_2_FLR_6 | 4.5531 | 39.02 | 177.65 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 1.42 |
ROOM_3_MULT9_FLR_6_LIGHTS | ROOM_3_MULT9_FLR_6 | 4.5531 | 220.77 | 1005.22 | LightsWired | BLDG_LIGHT_GUESTROOM_SCH | 42.59 | 168.00 | 42.64 | 0.0000 | Y | 8.05 |
BANQUET_FLR_6_LIGHTS | BANQUET_FLR_6 | 10.3656 | 331.66 | 3437.84 | LightsWired | BLDG_LIGHT_MISC_SCH | 58.69 | 168.00 | 53.98 | 0.0000 | Y | 34.84 |
DINING_FLR_6_LIGHTS | DINING_FLR_6 | 10.3656 | 331.66 | 3437.84 | LightsWired | BLDG_LIGHT_MISC_SCH | 58.69 | 168.00 | 53.98 | 0.0000 | Y | 34.84 |
KITCHEN_FLR_6_LIGHTS | KITCHEN_FLR_6 | 11.7219 | 103.30 | 1210.92 | LightsWired | BLDG_LIGHT_MISC_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 13.33 |
CORRIDOR_FLR_6_LIGHTS | CORRIDOR_FLR_6 | 6.3938 | 412.12 | 2635.03 | LightsWired | BLDG_LIGHT_CORRIDOR_SCH | 58.69 | 168.00 | 58.63 | 0.0000 | Y | 29.00 |
Interior Lighting Total | 6.8961 | 11345.29 | 78237.74 | 527.29 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CAFE_FLR_1_DAYLREFPT1 | CAFE_FLR_1 | CAFE_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.39 | 1957.68 | 763.49 |
CAFE_FLR_1_DAYLREFPT2 | CAFE_FLR_1 | CAFE_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.00 | 1957.68 | 0.00 |
LOBBY_FLR_1_DAYLREFPT1 | LOBBY_FLR_1 | LOBBY_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.07 | 13433.46 | 940.34 |
LOBBY_FLR_1_DAYLREFPT2 | LOBBY_FLR_1 | LOBBY_FLR_1_DAYLCTRL | SplitFlux | Stepped | 0.00 | 13433.46 | 0.00 |
BANQUET_FLR_6_DAYLREFPT1 | BANQUET_FLR_6 | BANQUET_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.20 | 3437.84 | 687.57 |
BANQUET_FLR_6_DAYLREFPT2 | BANQUET_FLR_6 | BANQUET_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.00 | 3437.84 | 0.00 |
DINING_FLR_6_DAYLREFPT1 | DINING_FLR_6 | DINING_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.20 | 3437.84 | 687.57 |
DINING_FLR_6_DAYLREFPT2 | DINING_FLR_6 | DINING_FLR_6_DAYLCTRL | SplitFlux | Stepped | 0.00 | 3437.84 | 0.00 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR FACADE LIGHTING | 14423.55 | AstronomicalClock | - | 83.75 | 83.75 | 226.76 | |
Exterior Lighting Total | 14423.55 | 226.76 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
HEATSYS1 BOILER | Boiler:HotWater | 267010.60 | 0.80 | ||
COOLSYS1 CHILLER | Chiller:Electric:EIR | 650353.95 | 2.96 | 4.04 | 13.79 |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
ROOM_1_FLR_3 FAN COILCOOL COIL | Coil:Cooling:Water | 9783.93 | 14792.10 | 11901.08 | 2891.03 | 0.80 | - | 1708.06 | 17.32 |
ROOM_2_FLR_3 FAN COILCOOL COIL | Coil:Cooling:Water | 9557.10 | 14446.75 | 11621.76 | 2824.99 | 0.80 | - | 1668.10 | 16.92 |
ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | Coil:Cooling:Water | 52341.22 | 79741.13 | 64506.42 | 15234.71 | 0.81 | - | 9239.90 | 93.72 |
ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | Coil:Cooling:Water | 57988.59 | 86053.99 | 68306.26 | 17747.73 | 0.79 | - | 9882.91 | 100.24 |
ROOM_5_FLR_3 FAN COILCOOL COIL | Coil:Cooling:Water | 8489.33 | 12820.73 | 10306.51 | 2514.23 | 0.80 | - | 1479.91 | 15.01 |
ROOM_6_FLR_3 FAN COILCOOL COIL | Coil:Cooling:Water | 8406.36 | 12694.44 | 10204.39 | 2490.05 | 0.80 | - | 1465.29 | 14.86 |
ROOM_1_FLR_6 FAN COILCOOL COIL | Coil:Cooling:Water | 2525.96 | 3819.78 | 3073.73 | 746.05 | 0.80 | - | 441.11 | 4.47 |
ROOM_2_FLR_6 FAN COILCOOL COIL | Coil:Cooling:Water | 2467.64 | 3730.98 | 3001.92 | 729.06 | 0.80 | - | 430.83 | 4.37 |
ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | Coil:Cooling:Water | 11133.59 | 16698.91 | 13356.13 | 3342.79 | 0.80 | - | 1923.50 | 19.51 |
VAV WITH REHEAT_COOLC | Coil:Cooling:Water | 439146.39 | 557144.35 | 375052.06 | 182092.28 | 0.67 | - | 85647.31 | 868.68 |
FLR_3_DOAS_COOLC | Coil:Cooling:Water | 47940.88 | 56669.74 | 38137.19 | 18532.55 | 0.67 | - | 7894.17 | 80.07 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
None |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
None |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
BASEMENT VAV BOX REHEAT COIL | Coil:Heating:Water | 7196.63 | 7237.99 | - |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 2828.65 | 2846.81 | - |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 1273.53 | 1280.53 | - |
MECH_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 1616.73 | 1625.77 | - |
STORAGE_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 924.03 | 929.97 | - |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 11386.89 | 11451.84 | - |
CAFE_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 8909.05 | 8955.85 | - |
LOBBY_FLR_1 VAV BOX REHEAT COIL | Coil:Heating:Water | 24520.44 | 24655.35 | - |
ROOM_1_FLR_3 FAN COILHEAT COIL | Coil:Heating:Water | 3634.44 | 3921.75 | - |
ROOM_2_FLR_3 FAN COILHEAT COIL | Coil:Heating:Water | 3635.01 | 3922.36 | - |
ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | Coil:Heating:Water | 21042.69 | 22706.07 | - |
ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | Coil:Heating:Water | 21088.33 | 22755.31 | - |
ROOM_5_FLR_3 FAN COILHEAT COIL | Coil:Heating:Water | 3633.75 | 3921.00 | - |
ROOM_6_FLR_3 FAN COILHEAT COIL | Coil:Heating:Water | 3634.31 | 3921.61 | - |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | Coil:Heating:Water | 9299.81 | 9360.96 | - |
ROOM_1_FLR_6 FAN COILHEAT COIL | Coil:Heating:Water | 1127.98 | 1217.13 | - |
ROOM_2_FLR_6 FAN COILHEAT COIL | Coil:Heating:Water | 1129.93 | 1219.24 | - |
ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | Coil:Heating:Water | 5463.03 | 5894.78 | - |
BANQUET_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 10125.81 | 10182.08 | - |
DINING_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 10453.58 | 10511.76 | - |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 6768.07 | 6806.97 | - |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | Coil:Heating:Water | 5686.14 | 5721.83 | - |
VAV WITH REHEAT_HEATC | Coil:Heating:Water | 92205.04 | 77497.57 | - |
FLR_3_DOAS_HEATC | Coil:Heating:Water | 9426.70 | 7923.07 | - |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
LAUNDRY_FLR_1 EXHAUST FAN | Fan:ZoneExhaust | 0.39 | 125.00 | 0.24 | 76.61 | 324.68 | 1.00 | 2.78 | General | ||
LOBBY_FLR_1 DUMMY EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 | General | |||
ROOM_1_FLR_3 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.89 | 628.52 | 703.64 | 1.00 | 1.23 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 |
ROOM_2_FLR_3 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.87 | 613.65 | 703.64 | 1.00 | 1.23 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 |
ROOM_3_MULT19_FLR_3 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 4.88 | 3432.99 | 703.64 | 1.00 | 0.97 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 |
ROOM_4_MULT19_FLR_3 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 5.02 | 3533.85 | 703.64 | 1.00 | 0.97 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 |
ROOM_5_FLR_3 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.77 | 543.63 | 703.64 | 1.00 | 1.27 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 |
ROOM_6_FLR_3 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.76 | 538.19 | 703.64 | 1.00 | 1.27 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
ROOM_1_FLR_6 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.23 | 162.37 | 703.64 | 1.00 | 1.92 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 |
ROOM_2_FLR_6 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.23 | 158.55 | 703.64 | 1.00 | 1.94 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 |
ROOM_3_MULT9_FLR_6 FAN COILFAN | Fan:OnOff | 0.39 | 270.90 | 0.99 | 699.08 | 703.64 | 1.00 | 1.20 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 |
BANQUET_FLR_6 DUMMY EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.87 | 0.00 | 0.00 | 1.00 | 0.00 | General | ||
DINING_FLR_6 DUMMY EXHAUST FAN | Fan:ZoneExhaust | 1.00 | 0.00 | 0.87 | 0.00 | 0.00 | 1.00 | 0.00 | General | ||
KITCHEN_FLR_6 EXHAUST FAN | Fan:ZoneExhaust | 0.39 | 125.00 | 1.89 | 612.92 | 324.68 | 1.00 | 1.48 | General | ||
VAV WITH REHEAT_FAN | Fan:VariableVolume | 0.62 | 1389.42 | 20.06 | 44954.63 | 2240.64 | 1.00 | 1.11 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 |
FLR_3_DOAS_FAN | Fan:ConstantVolume | 0.58 | 622.50 | 2.05 | 2194.88 | 1070.05 | 1.00 | 1.30 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
COOLSYS1 PUMP SECONDARY | Pump:VariableSpeed | Intermittent | 168135.01 | 0.023209 | 5558.65 | 239508.57 | 0.90 | General |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000375 | 47.91 | 127739.32 | 0.30 | General |
HEATSYS1 PUMP | Pump:VariableSpeed | Intermittent | 179352.00 | 0.005899 | 1507.19 | 255487.18 | 0.90 | General |
COOLSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 56045.00 | 0.023209 | 1852.88 | 79836.19 | 0.90 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SHW BOOSTER WATER HEATER | WaterHeater:Mixed | 0.02 | 8000.00 | 1.00 | 1.24 | 1.15 |
SWH LAUNDRY | WaterHeater:Mixed | 1.14 | 87921.32 | 0.80 | 0.54 | 0.50 |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 2.27 | 175842.60 | 0.80 | 0.00 | 0.00 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 31903.54 | 31903.54 | 16.12 | 2.362 | 2.362 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 20:00:00 | 24.00 | 24.00 | 0.00926 | 26.85 | 0.00820 | 0.854 | 0.00 |
RETAIL_1_FLR_1 | 3959.02 | 3959.02 | 59.03 | 0.293 | 0.293 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | 24.00 | 24.00 | 0.00907 | 30.93 | 0.00820 | 0.079 | 0.00 |
RETAIL_2_FLR_1 | 3109.49 | 3109.49 | 40.04 | 0.230 | 0.230 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:50:00 | 24.00 | 24.00 | 0.00939 | 30.17 | 0.00820 | 0.092 | 0.00 |
LAUNDRY_FLR_1 | 44738.66 | 44738.66 | 573.28 | 3.312 | 3.312 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:40:00 | 24.00 | 24.00 | 0.00854 | 31.30 | 0.00820 | 0.236 | 0.00 |
CAFE_FLR_1 | 17228.80 | 17228.80 | 91.22 | 1.277 | 1.277 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | 24.00 | 23.99 | 0.01029 | 30.93 | 0.00820 | 0.676 | 0.00 |
LOBBY_FLR_1 | 60722.48 | 60722.48 | 46.42 | 4.497 | 4.497 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 24.00 | 23.99 | 0.01004 | 31.00 | 0.00820 | 1.893 | 0.00 |
ROOM_1_FLR_3 | 8953.89 | 8953.89 | 229.46 | 0.893 | 0.893 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 21.11 | 21.11 | 0.00858 | 30.41 | 0.00820 | 0.062 | 0.00 |
ROOM_2_FLR_3 | 8742.09 | 8742.09 | 224.06 | 0.872 | 0.872 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 21.11 | 21.11 | 0.00858 | 30.41 | 0.00820 | 0.062 | 0.00 |
ROOM_3_MULT19_FLR_3 | 48908.84 | 48908.84 | 1994.34 | 4.879 | 4.879 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 21.11 | 21.11 | 0.00849 | 31.00 | 0.00820 | 0.837 | 0.00 |
ROOM_4_MULT19_FLR_3 | 50341.75 | 50341.75 | 2052.21 | 5.022 | 5.022 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | 21.11 | 21.11 | 0.00877 | 31.30 | 0.00820 | 0.837 | 0.00 |
ROOM_5_FLR_3 | 7744.58 | 7744.58 | 198.47 | 0.773 | 0.773 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 | 21.11 | 21.11 | 0.00859 | 26.66 | 0.00820 | 0.062 | 0.00 |
ROOM_6_FLR_3 | 7667.17 | 7667.17 | 196.51 | 0.765 | 0.765 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.11 | 21.11 | 0.00859 | 26.41 | 0.00820 | 0.062 | 0.00 |
ROOM_1_FLR_6 | 2313.13 | 2313.13 | 59.28 | 0.231 | 0.231 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 21.11 | 21.11 | 0.00857 | 30.41 | 0.00820 | 0.015 | 0.00 |
ROOM_2_FLR_6 | 2258.67 | 2258.67 | 57.89 | 0.225 | 0.225 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 21.11 | 21.11 | 0.00857 | 30.41 | 0.00820 | 0.015 | 0.00 |
ROOM_3_MULT9_FLR_6 | 9958.88 | 9958.88 | 405.98 | 0.994 | 0.994 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 21.11 | 21.11 | 0.00866 | 31.08 | 0.00820 | 0.099 | 0.00 |
BANQUET_FLR_6 | 28119.31 | 28119.31 | 84.78 | 2.084 | 2.084 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:10:00 | 24.00 | 23.98 | 0.01049 | 31.30 | 0.00820 | 1.187 | 0.00 |
DINING_FLR_6 | 29533.83 | 29533.83 | 89.05 | 2.189 | 2.189 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:10:00 | 24.00 | 23.99 | 0.01040 | 31.30 | 0.00820 | 1.187 | 0.00 |
KITCHEN_FLR_6 | 29925.80 | 29925.80 | 289.69 | 2.221 | 2.221 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 12:30:00 | 24.00 | 23.97 | 0.01011 | 30.50 | 0.00820 | 0.367 | 0.00 |
MECH_FLR_1 | 2854.36 | 2854.36 | 17.38 | 0.211 | 0.211 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:20:00 | 24.00 | 24.00 | 0.00849 | 29.76 | 0.00820 | 0.000 | 0.00 |
STORAGE_FLR_1 | 1320.78 | 1320.78 | 13.94 | 0.098 | 0.098 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 24.00 | 24.00 | 0.00848 | 31.21 | 0.00820 | 0.058 | 0.00 |
CORRIDOR_FLR_3 | 11546.50 | 11546.50 | 29.65 | 0.855 | 1.187 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:10:00 | 24.00 | 24.00 | 0.00849 | 31.30 | 0.00820 | 0.475 | 0.00 |
CORRIDOR_FLR_6 | 7399.48 | 7399.48 | 17.95 | 0.548 | 0.548 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 24.00 | 24.00 | 0.00849 | 31.23 | 0.00820 | 0.126 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.000 | 0.854 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 0.00 | 21.00 | 0.00800 | 3.80 | 0.00506 | 0.854 | 0.00 | |
RETAIL_1_FLR_1 | 1936.58 | 1936.58 | 28.87 | 0.085 | 0.085 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00743 | 3.80 | 0.00506 | 0.079 | 0.00 |
RETAIL_2_FLR_1 | 572.60 | 572.60 | 7.37 | 0.025 | 0.092 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00757 | 3.80 | 0.00506 | 0.092 | 0.00 |
LAUNDRY_FLR_1 | 1306.12 | 1306.12 | 16.74 | 0.057 | 0.236 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00745 | 3.80 | 0.00506 | 0.236 | 0.00 |
CAFE_FLR_1 | 5023.64 | 5023.64 | 26.60 | 0.219 | 0.676 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00744 | 3.80 | 0.00506 | 0.676 | 0.00 |
LOBBY_FLR_1 | 10831.42 | 10831.42 | 8.28 | 0.473 | 1.893 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00748 | 3.80 | 0.00506 | 1.893 | 0.00 |
ROOM_1_FLR_3 | 3634.45 | 3634.45 | 93.14 | 0.160 | 0.160 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00762 | 3.80 | 0.00506 | 0.062 | 0.00 |
ROOM_2_FLR_3 | 3635.01 | 3635.01 | 93.16 | 0.160 | 0.160 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00762 | 3.80 | 0.00506 | 0.062 | 0.00 |
ROOM_3_MULT19_FLR_3 | 21042.71 | 21042.71 | 858.05 | 0.924 | 0.924 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00765 | 3.80 | 0.00506 | 0.837 | 0.00 |
ROOM_4_MULT19_FLR_3 | 21088.34 | 21088.34 | 859.68 | 0.926 | 0.926 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00765 | 3.80 | 0.00506 | 0.837 | 0.00 |
ROOM_5_FLR_3 | 3633.75 | 3633.75 | 93.12 | 0.160 | 0.160 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00762 | 3.80 | 0.00506 | 0.062 | 0.00 |
ROOM_6_FLR_3 | 3634.32 | 3634.32 | 93.15 | 0.160 | 0.160 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00762 | 3.80 | 0.00506 | 0.062 | 0.00 |
ROOM_1_FLR_6 | 1127.98 | 1127.98 | 28.91 | 0.050 | 0.050 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00768 | 3.80 | 0.00506 | 0.015 | 0.00 |
ROOM_2_FLR_6 | 1129.94 | 1129.94 | 28.96 | 0.050 | 0.050 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00768 | 3.80 | 0.00506 | 0.015 | 0.00 |
ROOM_3_MULT9_FLR_6 | 5463.04 | 5463.04 | 222.70 | 0.240 | 0.240 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.11 | 21.11 | 0.00770 | 3.80 | 0.00506 | 0.099 | 0.00 |
BANQUET_FLR_6 | 3778.23 | 3778.23 | 11.39 | 0.165 | 1.187 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | 21.00 | 21.00 | 0.00776 | 3.80 | 0.00506 | 1.187 | 0.00 |
DINING_FLR_6 | 3786.63 | 3786.63 | 11.42 | 0.165 | 1.187 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 21.00 | 21.00 | 0.00776 | 3.80 | 0.00506 | 1.187 | 0.00 |
KITCHEN_FLR_6 | 0.00 | 0.00 | 0.00 | 0.000 | 0.367 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 0.00 | 21.00 | 0.00800 | 3.80 | 0.00506 | 0.367 | 0.00 | |
MECH_FLR_1 | 973.60 | 973.60 | 5.93 | 0.043 | 0.043 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00747 | 3.80 | 0.00506 | 0.000 | 0.00 |
STORAGE_FLR_1 | 626.45 | 626.45 | 6.61 | 0.027 | 0.058 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00743 | 3.80 | 0.00506 | 0.058 | 0.00 |
CORRIDOR_FLR_3 | 5685.49 | 5685.49 | 14.60 | 0.248 | 0.475 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 21.00 | 21.00 | 0.00769 | 3.80 | 0.00506 | 0.475 | 0.00 |
CORRIDOR_FLR_6 | 4017.88 | 4017.88 | 9.75 | 0.175 | 0.175 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 21.00 | 21.00 | 0.00780 | 3.80 | 0.00506 | 0.126 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
VAV WITH REHEAT | 20.06 | 20.06 | 7.33 | 7.33 | 20.0633 | 12.0598 | 20.0633 | 0.6011 | 0.3000 |
FLR_3_DOAS | 13.86 | 2.05 | 2.83 | 2.05 | 2.0512 | 2.0512 | 2.0512 | 1.0000 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
BASEMENT VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | BASEMENT VAV BOX | 7196.631 | 7196.631 | 1.388824 | 0.00015900 | 127.348 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 7237.99 | 7196.63 | 1.388824 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00800000 | 50.7558 | 0.00 | 0.00 | 7239.32 | 7239.32 |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_1_FLR_1 VAV BOX | 2828.649 | 2828.649 | 0.172357 | 0.00006250 | 55.951 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 2846.81 | 2828.65 | 0.172357 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00743063 | 47.1880 | 1936.58 | 0.00 | 2847.72 | 2847.72 |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_2_FLR_1 VAV BOX | 1273.532 | 1273.532 | 0.135377 | 0.00002814 | 23.620 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1280.53 | 1273.53 | 0.135377 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00757166 | 48.0713 | 572.60 | 0.00 | 1280.96 | 1280.96 |
MECH_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | MECH_FLR_1 VAV BOX | 1616.735 | 1616.735 | 0.124239 | 0.00003572 | 31.281 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1625.77 | 1616.73 | 0.124239 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00746804 | 47.4212 | 973.60 | 0.00 | 1626.13 | 1626.13 |
STORAGE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | STORAGE_FLR_1 VAV BOX | 924.029 | 924.029 | 0.057488 | 0.00002042 | 18.237 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 929.97 | 924.03 | 0.057488 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00743350 | 47.2046 | 626.45 | 0.00 | 930.26 | 930.26 |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 11386.889 | 11386.889 | 1.947527 | 0.00025158 | 202.956 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 11451.84 | 11386.89 | 1.947527 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00745062 | 47.3126 | 1306.12 | 0.00 | 11454.21 | 11454.21 |
CAFE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CAFE_FLR_1 VAV BOX | 8909.054 | 8909.054 | 0.750681 | 0.00019683 | 170.029 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 8955.85 | 8909.05 | 0.750681 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00744317 | 47.2665 | 5023.64 | 0.00 | 8959.72 | 8959.72 |
LOBBY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 24520.441 | 24520.441 | 2.644374 | 0.00054175 | 454.084 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 24655.35 | 24520.44 | 2.644374 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00747736 | 47.4799 | 10831.42 | 0.00 | 24663.56 | 24663.56 |
ROOM_1_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | 9783.934 | -999.000 | 0.893239 | 0.00034945 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | 8/21 16:30:00 | 9783.93 | 9610.66 | 0.893239 | 21.69 | 15.42 | 0.00857515 | 12.80 | 11.93 | 0.00850000 | 30.41 | 0.00820219 | 18.11 | 0.0000 | 21.11 | 0.00857515 | 53.9869 | 8953.89 | 0.00 | 9960.25 | 9610.16 |
ROOM_1_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | 3634.444 | 3634.444 | 0.159664 | 0.00008030 | 82.740 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3921.75 | 3634.44 | 0.159664 | 21.11 | 14.35 | 0.00761741 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00761741 | 48.0304 | 3634.45 | 0.00 | 3923.52 | 3923.52 |
ROOM_2_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | 9557.099 | -999.000 | 0.872110 | 0.00034135 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | 8/21 16:30:00 | 9557.10 | 9383.96 | 0.872110 | 21.69 | 15.42 | 0.00857691 | 12.80 | 11.93 | 0.00850000 | 30.41 | 0.00820219 | 18.11 | 0.0000 | 21.11 | 0.00857691 | 53.9979 | 8742.09 | 0.00 | 9729.28 | 9383.53 |
ROOM_2_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | 3635.007 | 3635.007 | 0.159688 | 0.00008031 | 82.753 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3922.36 | 3635.01 | 0.159688 | 21.11 | 14.35 | 0.00761749 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00761749 | 48.0309 | 3635.01 | 0.00 | 3924.13 | 3924.13 |
ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | 52341.215 | -999.000 | 4.878924 | 0.00186947 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | unknown | 8/21 13:20:00 | 52341.22 | 52341.22 | 4.878924 | 21.69 | 15.35 | 0.00849315 | 12.80 | 11.93 | 0.00849315 | 31.00 | 0.00820219 | 18.30 | 0.0000 | 21.11 | 0.00849315 | 53.4765 | 48908.84 | 0.00 | 53285.63 | 52369.52 |
ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | 21042.694 | 21042.694 | 0.924431 | 0.00046491 | 479.046 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 22706.07 | 21042.69 | 0.924431 | 21.11 | 14.37 | 0.00764580 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00764580 | 48.2066 | 21042.71 | 0.00 | 22716.49 | 22716.49 |
ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | 57988.592 | -999.000 | 5.022263 | 0.00207118 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | unknown | 8/21 14:50:00 | 57988.59 | 54426.42 | 5.022263 | 21.69 | 15.60 | 0.00877281 | 12.80 | 11.93 | 0.00850000 | 31.30 | 0.00820219 | 18.40 | 0.0000 | 21.11 | 0.00877281 | 55.2150 | 50341.75 | 0.00 | 59006.41 | 54466.07 |
ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | 21088.328 | 21088.328 | 0.926435 | 0.00046592 | 480.085 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 22755.31 | 21088.33 | 0.926435 | 21.11 | 14.37 | 0.00764639 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00764639 | 48.2103 | 21088.34 | 0.00 | 22765.76 | 22765.76 |
ROOM_5_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | 8489.329 | -999.000 | 0.772598 | 0.00030321 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 | unknown | 8/21 09:10:00 | 8489.33 | 8316.32 | 0.772598 | 21.69 | 15.43 | 0.00858672 | 12.80 | 11.93 | 0.00850000 | 26.66 | 0.00820219 | 16.85 | 0.0000 | 21.11 | 0.00858672 | 54.0588 | 7744.58 | 0.00 | 8642.07 | 8316.27 |
ROOM_5_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | 3633.747 | 3633.747 | 0.159633 | 0.00008028 | 82.724 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3921.00 | 3633.75 | 0.159633 | 21.11 | 14.35 | 0.00761735 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00761735 | 48.0300 | 3633.75 | 0.00 | 3922.77 | 3922.77 |
ROOM_6_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | 8406.355 | -999.000 | 0.764876 | 0.00030025 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | unknown | 8/21 09:00:00 | 8406.36 | 8233.46 | 0.764876 | 21.69 | 15.43 | 0.00858753 | 12.80 | 11.93 | 0.00850000 | 26.41 | 0.00820219 | 16.76 | 0.0000 | 21.11 | 0.00858753 | 54.0638 | 7667.17 | 0.00 | 8557.59 | 8233.44 |
ROOM_6_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | 3634.311 | 3634.311 | 0.159658 | 0.00008030 | 82.737 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3921.61 | 3634.31 | 0.159658 | 21.11 | 14.35 | 0.00761742 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00761742 | 48.0305 | 3634.32 | 0.00 | 3923.38 | 3923.38 |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_3 VAV BOX | 9299.807 | 9299.807 | 0.697900 | 0.00020547 | 180.476 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 9360.96 | 9299.81 | 0.697900 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00769350 | 48.8352 | 5685.49 | 0.00 | 9363.13 | 9363.13 |
ROOM_1_FLR_6 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | 2525.962 | -999.000 | 0.230757 | 0.00009022 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | 8/21 16:30:00 | 2525.96 | 2482.58 | 0.230757 | 21.69 | 15.42 | 0.00857284 | 12.80 | 11.93 | 0.00850000 | 30.41 | 0.00820219 | 18.11 | 0.0000 | 21.11 | 0.00857284 | 53.9726 | 2313.13 | 0.00 | 2571.50 | 2482.42 |
ROOM_1_FLR_6 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | 1127.982 | 1127.982 | 0.049553 | 0.00002492 | 25.679 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1217.13 | 1127.98 | 0.049553 | 21.11 | 14.41 | 0.00768375 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00768375 | 48.4436 | 1127.98 | 0.00 | 1217.70 | 1217.70 |
ROOM_2_FLR_6 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | 2467.636 | -999.000 | 0.225325 | 0.00008814 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | 8/21 16:30:00 | 2467.64 | 2424.29 | 0.225325 | 21.69 | 15.42 | 0.00857453 | 12.80 | 11.93 | 0.00850000 | 30.41 | 0.00820219 | 18.11 | 0.0000 | 21.11 | 0.00857453 | 53.9831 | 2258.67 | 0.00 | 2512.11 | 2424.16 |
ROOM_2_FLR_6 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | 1129.934 | 1129.934 | 0.049639 | 0.00002496 | 25.723 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1219.24 | 1129.93 | 0.049639 | 21.11 | 14.41 | 0.00768427 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00768427 | 48.4468 | 1129.94 | 0.00 | 1219.81 | 1219.81 |
ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | COIL:COOLING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | 11133.589 | -999.000 | 0.993524 | 0.00039766 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | unknown | 8/21 13:30:00 | 11133.59 | 10723.33 | 0.993524 | 21.69 | 15.50 | 0.00865947 | 12.80 | 11.93 | 0.00850000 | 31.08 | 0.00820219 | 18.33 | 0.0000 | 21.11 | 0.00865947 | 54.5113 | 9958.88 | 0.00 | 11331.95 | 10726.40 |
ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | 5463.035 | 5463.035 | 0.239996 | 0.00012070 | 124.366 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 5894.78 | 5463.03 | 0.239996 | 21.11 | 14.42 | 0.00769775 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.11 | 0.00769775 | 48.5306 | 5463.04 | 0.00 | 5897.57 | 5897.57 |
BANQUET_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 10125.810 | 10125.810 | 1.225585 | 0.00022372 | 185.375 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | 10182.08 | 10125.81 | 1.225585 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00776124 | 49.2605 | 3778.23 | 0.00 | 10185.09 | 10185.09 |
DINING_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 10453.583 | 10453.583 | 1.287216 | 0.00023096 | 191.073 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 10511.76 | 10453.58 | 1.287216 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00776140 | 49.2612 | 3786.63 | 0.00 | 10514.81 | 10514.81 |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | 6768.072 | 6768.072 | 1.306120 | 0.00014953 | 119.764 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6806.97 | 6768.07 | 1.306120 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00800000 | 50.7558 | 0.00 | 0.00 | 6808.21 | 6808.21 |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_6 VAV BOX | 5686.138 | 5686.138 | 0.322070 | 0.00012563 | 113.408 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 5721.83 | 5686.14 | 0.322070 | 16.70 | 13.01 | 0.00800000 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 21.00 | 0.00780019 | 49.5042 | 4017.88 | 0.00 | 5723.87 | 5723.87 |
VAV WITH REHEAT_COOLC | Coil:Cooling:Water | AirLoopHVAC | VAV WITH REHEAT | 439146.391 | -999.000 | 20.063311 | 0.01568529 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 439146.39 | 418018.88 | 20.063311 | 28.38 | 17.91 | 0.00878275 | 10.94 | 10.94 | 0.00843576 | 31.30 | 0.00820219 | 18.40 | 60.0612 | 23.99 | 0.00946970 | 49.9740 | 270719.68 | 0.00 | 494604.00 | 434248.62 |
VAV WITH REHEAT_HEATC | Coil:Heating:Water | AirLoopHVAC | VAV WITH REHEAT | 92205.040 | 92205.040 | 6.018993 | 0.00203716 | 1451.965 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 77497.57 | 92205.04 | 6.018993 | 3.80 | 3.80 | 0.00505843 | 16.70 | 13.01 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 200.2039 | 21.00 | 0.00767754 | 48.7355 | 38469.32 | 0.00 | 77489.40 | 77489.40 |
FLR_3_DOAS_COOLC | Coil:Cooling:Water | AirLoopHVAC | FLR_3_DOAS | 47940.876 | -999.000 | 2.051199 | 0.00171234 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 47940.88 | 47940.88 | 2.051199 | 31.30 | 18.40 | 0.00820219 | 10.94 | 11.63 | 0.00820219 | 31.30 | 0.00820219 | 18.40 | 100.0000 | 21.11 | 0.00863433 | 54.3544 | 138957.95 | 0.00 | 53222.24 | 50929.65 |
FLR_3_DOAS_HEATC | Coil:Heating:Water | AirLoopHVAC | FLR_3_DOAS | 9426.704 | 9426.704 | 0.615360 | 0.00020827 | 148.444 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 7923.07 | 9426.70 | 0.615360 | 3.80 | 3.80 | 0.00505843 | 16.70 | 13.01 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 333.3333 | 21.11 | 0.00764639 | 48.2103 | 64389.54 | 0.00 | 7922.23 | 7922.23 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
BASEMENT VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | BASEMENT VAV BOX | BASEMENT | N/A | N/A | N/A | Yes | Yes | Yes | No | 7196.631 | 7196.631 | 1.388824 | 0.00015900 | 127.348 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 2.6573 | 2.695261 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 7237.99 | 7196.63 | 1.0000 | 1.64128290 | 1.388824 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.15898456 | 60.00 | 49.00 | 11.00 | 0.000 | 7237.99 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00800000 | 21.00 | 0.00800000 | 50.7558 | 0.00 | 0.00 | 7239.32 | 7239.32 | 1.64128290 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 20.93 | 14.81 | 0.00800000 | 41345.5 | |
RETAIL_1_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_1_FLR_1 VAV BOX | RETAIL_1_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2828.649 | 2828.649 | 0.172357 | 0.00006250 | 55.951 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 1.0451 | 1.059377 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 2846.81 | 2828.65 | 1.0000 | 0.20368817 | 0.172357 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.06248917 | 60.00 | 49.00 | 11.00 | 0.000 | 2846.81 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00743063 | 21.00 | 0.00743063 | 47.1880 | 1936.58 | 0.00 | 2847.72 | 2847.72 | 0.20368817 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 30.31 | 18.12 | 0.00800000 | 50915.5 | |
RETAIL_2_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | RETAIL_2_FLR_1 VAV BOX | RETAIL_2_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1273.532 | 1273.532 | 0.135377 | 0.00002814 | 23.620 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 0.4701 | 0.476959 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1280.53 | 1273.53 | 1.0000 | 0.15998539 | 0.135377 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.02813426 | 60.00 | 49.00 | 11.00 | 0.000 | 1280.53 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00757166 | 21.00 | 0.00757166 | 48.0713 | 572.60 | 0.00 | 1280.96 | 1280.96 | 0.15998539 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 24.45 | 16.10 | 0.00800000 | 44941.5 | |
MECH_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | MECH_FLR_1 VAV BOX | MECH_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1616.735 | 1616.735 | 0.124239 | 0.00003572 | 31.281 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 0.5969 | 0.605495 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1625.77 | 1616.73 | 1.0000 | 0.14682294 | 0.124239 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.03571613 | 60.00 | 49.00 | 11.00 | 0.000 | 1625.77 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00746804 | 21.00 | 0.00746804 | 47.4212 | 973.60 | 0.00 | 1626.13 | 1626.13 | 0.14682294 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 27.46 | 17.15 | 0.00800000 | 48010.2 | |
STORAGE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | STORAGE_FLR_1 VAV BOX | STORAGE_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 924.029 | 924.029 | 0.057488 | 0.00002042 | 18.237 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 0.3414 | 0.346065 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 929.97 | 924.03 | 1.0000 | 0.06793829 | 0.057488 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.02041321 | 60.00 | 49.00 | 11.00 | 0.000 | 929.97 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00743350 | 21.00 | 0.00743350 | 47.2046 | 626.45 | 0.00 | 930.26 | 930.26 | 0.06793829 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 30.03 | 18.02 | 0.00800000 | 50627.5 | |
LAUNDRY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | LAUNDRY_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11386.889 | 11386.889 | 1.947527 | 0.00025158 | 202.956 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 4.2043 | 4.264583 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 11451.84 | 11386.89 | 1.0000 | 2.30154576 | 1.947527 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.25155373 | 60.00 | 49.00 | 11.00 | 0.000 | 11451.84 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00745062 | 21.00 | 0.00745062 | 47.3126 | 1306.12 | 0.00 | 11454.21 | 11454.21 | 2.30154576 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 21.48 | 15.02 | 0.00800000 | 41911.5 | |
CAFE_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CAFE_FLR_1 VAV BOX | CAFE_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 8909.054 | 8909.054 | 0.750681 | 0.00019683 | 170.029 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 3.2879 | 3.336592 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 8955.85 | 8909.05 | 1.0000 | 0.88713918 | 0.750681 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.19681458 | 60.00 | 49.00 | 11.00 | 0.000 | 8955.85 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00744317 | 21.00 | 0.00744317 | 47.2665 | 5023.64 | 0.00 | 8959.72 | 8959.72 | 0.88713918 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 26.50 | 16.82 | 0.00800000 | 47034.3 | |
LOBBY_FLR_1 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | LOBBY_FLR_1 | N/A | N/A | N/A | Yes | Yes | Yes | No | 24520.441 | 24520.441 | 2.644374 | 0.00054175 | 454.084 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 9.0517 | 9.183321 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 24655.35 | 24520.44 | 1.0000 | 3.12506536 | 2.644374 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.54169391 | 60.00 | 49.00 | 11.00 | 0.000 | 24655.35 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00747736 | 21.00 | 0.00747736 | 47.4799 | 10831.42 | 0.00 | 24663.56 | 24663.56 | 3.12506536 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 24.34 | 16.06 | 0.00800000 | 44826.9 | |
ROOM_1_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | ROOM_1_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 9783.934 | -999.000 | 0.893239 | 0.00034945 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7808 | 1004.8586 | 1.1818 | ROOM_1_FLR_3 FAN COILFAN | Fan:OnOff | 0.893239 | 1.05561080 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 1.5057 | 1.505707 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | unknown | unknown | 8/21 16:30:00 | 9783.93 | 9610.66 | 1.0000 | 1.05561080 | 0.893239 | 21.69 | 15.42 | 0.00857515 | 43590.7 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.34941729 | 6.70 | 11.72 | 6.67 | 0.000 | 9783.93 | 30.41 | 0.00820219 | 18.11 | 0.00000000 | 0.0000 | 21.11 | 0.00857515 | 21.11 | 0.00857515 | 53.9869 | 8953.89 | 0.00 | 9960.25 | 9610.16 | 1.05561080 | 21.69 | 15.61 | 0.00857515 | 43590.7 | 12.78 | 12.03 | 0.00844379 | 34155.2 | |
ROOM_1_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_3 FAN COIL | ROOM_1_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3634.444 | 3634.444 | 0.159664 | 0.00008030 | 82.740 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_1_FLR_3 FAN COILFAN | Fan:OnOff | 0.893239 | 1.05561080 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 1.4398 | 1.361161 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3921.75 | 3634.44 | 1.0000 | 0.18868697 | 0.159664 | 21.11 | 14.35 | 0.00761741 | 40562.4 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.08029041 | 60.00 | 49.00 | 11.00 | 0.000 | 3921.75 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00761741 | 21.11 | 0.00761741 | 48.0304 | 3634.45 | 0.00 | 3923.52 | 3923.52 | 0.18868697 | 16.60 | 12.77 | 0.00761741 | 35966.1 | 37.01 | 19.96 | 0.00761741 | 56759.9 | |
ROOM_2_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | ROOM_2_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 9557.099 | -999.000 | 0.872110 | 0.00034135 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7840 | 1004.8586 | 1.1818 | ROOM_2_FLR_3 FAN COILFAN | Fan:OnOff | 0.872110 | 1.03064079 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 1.4708 | 1.470798 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | unknown | unknown | 8/21 16:30:00 | 9557.10 | 9383.96 | 1.0000 | 1.03064079 | 0.872110 | 21.69 | 15.42 | 0.00857691 | 43595.2 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.34131624 | 6.70 | 11.72 | 6.67 | 0.000 | 9557.10 | 30.41 | 0.00820219 | 18.11 | 0.00000000 | 0.0000 | 21.11 | 0.00857691 | 21.11 | 0.00857691 | 53.9979 | 8742.09 | 0.00 | 9729.28 | 9383.53 | 1.03064079 | 21.69 | 15.61 | 0.00857691 | 43595.2 | 12.77 | 12.03 | 0.00844403 | 34155.1 | |
ROOM_2_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_3 FAN COIL | ROOM_2_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3635.007 | 3635.007 | 0.159688 | 0.00008031 | 82.753 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_2_FLR_3 FAN COILFAN | Fan:OnOff | 0.872110 | 1.03064079 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 1.4400 | 1.361372 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3922.36 | 3635.01 | 1.0000 | 0.18871620 | 0.159688 | 21.11 | 14.35 | 0.00761749 | 40562.6 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.08030286 | 60.00 | 49.00 | 11.00 | 0.000 | 3922.36 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00761749 | 21.11 | 0.00761749 | 48.0309 | 3635.01 | 0.00 | 3924.13 | 3924.13 | 0.18871620 | 16.60 | 12.77 | 0.00761749 | 35966.3 | 37.01 | 19.96 | 0.00761749 | 56760.1 | |
ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | ROOM_3_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 52341.215 | -999.000 | 4.878924 | 0.00186947 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.6283 | 1004.8586 | 1.1818 | ROOM_3_MULT19_FLR_3 FAN COILFAN | Fan:OnOff | 4.878924 | 5.76580834 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 8.0552 | 8.055096 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | unknown | unknown | unknown | 8/21 13:20:00 | 52341.22 | 52341.22 | 1.0000 | 5.76580834 | 4.878924 | 21.69 | 15.35 | 0.00849315 | 43382.8 | 12.80 | 11.93 | 0.00849315 | 34322.2 | 1.86928131 | 6.70 | 11.72 | 6.67 | 0.000 | 52341.22 | 31.00 | 0.00820219 | 18.30 | 0.00000000 | 0.0000 | 21.11 | 0.00849315 | 21.11 | 0.00849315 | 53.4765 | 48908.84 | 0.00 | 53285.63 | 52369.52 | 5.76580834 | 21.69 | 15.54 | 0.00849315 | 43382.8 | 12.80 | 12.03 | 0.00843022 | 34141.1 | |
ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT19_FLR_3 FAN COIL | ROOM_3_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 21042.694 | 21042.694 | 0.924431 | 0.00046491 | 479.046 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_3_MULT19_FLR_3 FAN COILFAN | Fan:OnOff | 4.878924 | 5.76580834 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 8.3360 | 7.880846 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 22706.07 | 21042.69 | 1.0000 | 1.09247241 | 0.924431 | 21.11 | 14.37 | 0.00764580 | 40634.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.46486518 | 60.00 | 49.00 | 11.00 | 0.000 | 22706.07 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00764580 | 21.11 | 0.00764580 | 48.2066 | 21042.71 | 0.00 | 22716.49 | 22716.49 | 1.09247241 | 16.60 | 12.80 | 0.00764580 | 36038.0 | 37.00 | 19.98 | 0.00764580 | 56831.6 | |
ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | ROOM_4_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 57988.592 | -999.000 | 5.022263 | 0.00207118 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1482 | 1004.8586 | 1.1818 | ROOM_4_MULT19_FLR_3 FAN COILFAN | Fan:OnOff | 5.022263 | 5.93520352 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 8.9244 | 8.924204 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:50:00 | unknown | unknown | unknown | 8/21 14:50:00 | 57988.59 | 54426.42 | 1.0000 | 5.93520352 | 5.022263 | 21.69 | 15.60 | 0.00877281 | 44092.5 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 2.07096819 | 6.70 | 11.72 | 6.67 | 0.000 | 57988.59 | 31.30 | 0.00820219 | 18.40 | 0.00000000 | 0.0000 | 21.11 | 0.00877281 | 21.11 | 0.00877281 | 55.2150 | 50341.75 | 0.00 | 59006.41 | 54466.07 | 5.93520352 | 21.69 | 15.79 | 0.00877281 | 44092.5 | 12.71 | 12.03 | 0.00846979 | 34150.7 | |
ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_4_MULT19_FLR_3 FAN COIL | ROOM_4_MULT19_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 21088.328 | 21088.328 | 0.926435 | 0.00046592 | 480.085 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_4_MULT19_FLR_3 FAN COILFAN | Fan:OnOff | 5.022263 | 5.93520352 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 8.3541 | 7.897937 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 22755.31 | 21088.33 | 1.0000 | 1.09484158 | 0.926435 | 21.11 | 14.37 | 0.00764639 | 40636.2 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.46587331 | 60.00 | 49.00 | 11.00 | 0.000 | 22755.31 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00764639 | 21.11 | 0.00764639 | 48.2103 | 21088.34 | 0.00 | 22765.76 | 22765.76 | 1.09484158 | 16.60 | 12.80 | 0.00764639 | 36039.5 | 37.00 | 19.98 | 0.00764639 | 56833.1 | |
ROOM_5_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | ROOM_5_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 8489.329 | -999.000 | 0.772598 | 0.00030321 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8023 | 1004.8586 | 1.1818 | ROOM_5_FLR_3 FAN COILFAN | Fan:OnOff | 0.772598 | 0.91303947 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 1.3065 | 1.306472 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:10:00 | unknown | unknown | unknown | 8/21 09:10:00 | 8489.33 | 8316.32 | 1.0000 | 0.91303947 | 0.772598 | 21.69 | 15.43 | 0.00858672 | 43620.1 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.30318255 | 6.70 | 11.72 | 6.67 | 0.000 | 8489.33 | 26.66 | 0.00820219 | 16.85 | 0.00000000 | 0.0000 | 21.11 | 0.00858672 | 21.11 | 0.00858672 | 54.0588 | 7744.58 | 0.00 | 8642.07 | 8316.27 | 0.91303947 | 21.69 | 15.62 | 0.00858672 | 43620.1 | 12.77 | 12.03 | 0.00844538 | 34154.9 | |
ROOM_5_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_5_FLR_3 FAN COIL | ROOM_5_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3633.747 | 3633.747 | 0.159633 | 0.00008028 | 82.724 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_5_FLR_3 FAN COILFAN | Fan:OnOff | 0.772598 | 0.91303947 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 1.4395 | 1.360900 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3921.00 | 3633.75 | 1.0000 | 0.18865077 | 0.159633 | 21.11 | 14.35 | 0.00761735 | 40562.2 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.08027501 | 60.00 | 49.00 | 11.00 | 0.000 | 3921.00 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00761735 | 21.11 | 0.00761735 | 48.0300 | 3633.75 | 0.00 | 3922.77 | 3922.77 | 0.18865077 | 16.60 | 12.77 | 0.00761735 | 35965.9 | 37.01 | 19.96 | 0.00761735 | 56759.8 | |
ROOM_6_FLR_3 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | ROOM_6_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 8406.355 | -999.000 | 0.764876 | 0.00030025 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.8038 | 1004.8586 | 1.1818 | ROOM_6_FLR_3 FAN COILFAN | Fan:OnOff | 0.764876 | 0.90391454 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 1.2937 | 1.293703 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | unknown | unknown | unknown | 8/21 09:00:00 | 8406.36 | 8233.46 | 1.0000 | 0.90391454 | 0.764876 | 21.69 | 15.43 | 0.00858753 | 43622.1 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.30021929 | 6.70 | 11.72 | 6.67 | 0.000 | 8406.36 | 26.41 | 0.00820219 | 16.76 | 0.00000000 | 0.0000 | 21.11 | 0.00858753 | 21.11 | 0.00858753 | 54.0638 | 7667.17 | 0.00 | 8557.59 | 8233.44 | 0.90391454 | 21.69 | 15.62 | 0.00858753 | 43622.1 | 12.77 | 12.03 | 0.00844549 | 34154.9 | |
ROOM_6_FLR_3 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_6_FLR_3 FAN COIL | ROOM_6_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 3634.311 | 3634.311 | 0.159658 | 0.00008030 | 82.737 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_6_FLR_3 FAN COILFAN | Fan:OnOff | 0.764876 | 0.90391454 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 1.4397 | 1.361111 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3921.61 | 3634.31 | 1.0000 | 0.18868004 | 0.159658 | 21.11 | 14.35 | 0.00761742 | 40562.4 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.08028747 | 60.00 | 49.00 | 11.00 | 0.000 | 3921.61 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00761742 | 21.11 | 0.00761742 | 48.0305 | 3634.32 | 0.00 | 3923.38 | 3923.38 | 0.18868004 | 16.60 | 12.77 | 0.00761742 | 35966.1 | 37.01 | 19.96 | 0.00761742 | 56760.0 | |
CORRIDOR_FLR_3 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_3 VAV BOX | CORRIDOR_FLR_3 | N/A | N/A | N/A | Yes | Yes | Yes | No | 9299.807 | 9299.807 | 0.697900 | 0.00020547 | 180.476 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 3.4367 | 3.482935 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 9360.96 | 9299.81 | 1.0000 | 0.82476381 | 0.697900 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.20544691 | 60.00 | 49.00 | 11.00 | 0.000 | 9360.96 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00769350 | 21.00 | 0.00769350 | 48.8352 | 5685.49 | 0.00 | 9363.13 | 9363.13 | 0.82476381 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 27.73 | 17.25 | 0.00800000 | 48287.2 | |
ROOM_1_FLR_6 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | ROOM_1_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2525.962 | -999.000 | 0.230757 | 0.00009022 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7765 | 1004.8586 | 1.1818 | ROOM_1_FLR_6 FAN COILFAN | Fan:OnOff | 0.230757 | 0.27270420 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 0.3887 | 0.388735 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | unknown | unknown | 8/21 16:30:00 | 2525.96 | 2482.58 | 1.0000 | 0.27270420 | 0.230757 | 21.69 | 15.42 | 0.00857284 | 43584.8 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.09021061 | 6.70 | 11.72 | 6.67 | 0.000 | 2525.96 | 30.41 | 0.00820219 | 18.11 | 0.00000000 | 0.0000 | 21.11 | 0.00857284 | 21.11 | 0.00857284 | 53.9726 | 2313.13 | 0.00 | 2571.50 | 2482.42 | 0.27270420 | 21.69 | 15.61 | 0.00857284 | 43584.8 | 12.78 | 12.03 | 0.00844347 | 34155.2 | |
ROOM_1_FLR_6 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_1_FLR_6 FAN COIL | ROOM_1_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1127.982 | 1127.982 | 0.049553 | 0.00002492 | 25.679 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_1_FLR_6 FAN COILFAN | Fan:OnOff | 0.230757 | 0.27270420 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 0.4468 | 0.422448 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1217.13 | 1127.98 | 1.0000 | 0.05856067 | 0.049553 | 21.11 | 14.41 | 0.00768375 | 40730.9 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.02491884 | 60.00 | 49.00 | 11.00 | 0.000 | 1217.13 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00768375 | 21.11 | 0.00768375 | 48.4436 | 1127.98 | 0.00 | 1217.70 | 1217.70 | 0.05856067 | 16.60 | 12.83 | 0.00768375 | 36134.1 | 37.00 | 20.01 | 0.00768375 | 56927.9 | |
ROOM_2_FLR_6 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | ROOM_2_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 2467.636 | -999.000 | 0.225325 | 0.00008814 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.7796 | 1004.8586 | 1.1818 | ROOM_2_FLR_6 FAN COILFAN | Fan:OnOff | 0.225325 | 0.26628422 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 0.3798 | 0.379759 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | unknown | unknown | unknown | 8/21 16:30:00 | 2467.64 | 2424.29 | 1.0000 | 0.26628422 | 0.225325 | 21.69 | 15.42 | 0.00857453 | 43589.1 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.08812759 | 6.70 | 11.72 | 6.67 | 0.000 | 2467.64 | 30.41 | 0.00820219 | 18.11 | 0.00000000 | 0.0000 | 21.11 | 0.00857453 | 21.11 | 0.00857453 | 53.9831 | 2258.67 | 0.00 | 2512.11 | 2424.16 | 0.26628422 | 21.69 | 15.61 | 0.00857453 | 43589.1 | 12.78 | 12.03 | 0.00844371 | 34155.2 | |
ROOM_2_FLR_6 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_2_FLR_6 FAN COIL | ROOM_2_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 1129.934 | 1129.934 | 0.049639 | 0.00002496 | 25.723 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_2_FLR_6 FAN COILFAN | Fan:OnOff | 0.225325 | 0.26628422 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 0.4476 | 0.423179 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 1219.24 | 1129.93 | 1.0000 | 0.05866200 | 0.049639 | 21.11 | 14.41 | 0.00768427 | 40732.2 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.02496196 | 60.00 | 49.00 | 11.00 | 0.000 | 1219.24 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00768427 | 21.11 | 0.00768427 | 48.4468 | 1129.94 | 0.00 | 1219.81 | 1219.81 | 0.05866200 | 16.60 | 12.83 | 0.00768427 | 36135.4 | 37.00 | 20.01 | 0.00768427 | 56929.2 | |
ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL | COIL:COOLING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | ROOM_3_MULT9_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 11133.589 | -999.000 | 0.993524 | 0.00039766 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9375 | 1004.8586 | 1.1818 | ROOM_3_MULT9_FLR_6 FAN COILFAN | Fan:OnOff | 0.993524 | 1.17412500 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 1.7134 | 1.713413 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | unknown | unknown | unknown | 8/21 13:30:00 | 11133.59 | 10723.33 | 1.0000 | 1.17412500 | 0.993524 | 21.69 | 15.50 | 0.00865947 | 43804.7 | 12.80 | 11.93 | 0.00850000 | 34322.2 | 0.39761799 | 6.70 | 11.72 | 6.67 | 0.000 | 11133.59 | 31.08 | 0.00820219 | 18.33 | 0.00000000 | 0.0000 | 21.11 | 0.00865947 | 21.11 | 0.00865947 | 54.5113 | 9958.88 | 0.00 | 11331.95 | 10726.40 | 1.17412500 | 21.69 | 15.69 | 0.00865947 | 43804.7 | 12.75 | 12.03 | 0.00845519 | 34153.3 | |
ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:FOURPIPEFANCOIL | ROOM_3_MULT9_FLR_6 FAN COIL | ROOM_3_MULT9_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 5463.035 | 5463.035 | 0.239996 | 0.00012070 | 124.366 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | ROOM_3_MULT9_FLR_6 FAN COILFAN | Fan:OnOff | 0.993524 | 1.17412500 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 2.1641 | 2.045999 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 5894.78 | 5463.03 | 1.0000 | 0.28362182 | 0.239996 | 21.11 | 14.42 | 0.00769775 | 40766.5 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.12068677 | 60.00 | 49.00 | 11.00 | 0.000 | 5894.78 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.11 | 0.00769775 | 21.11 | 0.00769775 | 48.5306 | 5463.04 | 0.00 | 5897.57 | 5897.57 | 0.28362182 | 16.60 | 12.85 | 0.00769775 | 36169.5 | 37.00 | 20.02 | 0.00769775 | 56963.3 | |
BANQUET_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | BANQUET_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10125.810 | 10125.810 | 1.225585 | 0.00022372 | 185.375 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 3.7381 | 3.792288 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 20:00:00 | 10182.08 | 10125.81 | 1.0000 | 1.44837068 | 1.225585 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.22369457 | 60.00 | 49.00 | 11.00 | 0.000 | 10182.08 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00776124 | 21.00 | 0.00776124 | 49.2605 | 3778.23 | 0.00 | 10185.09 | 10185.09 | 1.44837068 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 23.50 | 15.76 | 0.00800000 | 43966.8 | |
DINING_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | DINING_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 10453.583 | 10453.583 | 1.287216 | 0.00023096 | 191.073 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 3.8592 | 3.915044 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 10511.76 | 10453.58 | 1.0000 | 1.52120490 | 1.287216 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.23093559 | 60.00 | 49.00 | 11.00 | 0.000 | 10511.76 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00776140 | 21.00 | 0.00776140 | 49.2612 | 3786.63 | 0.00 | 10514.81 | 10514.81 | 1.52120490 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 23.38 | 15.71 | 0.00800000 | 43846.9 | |
KITCHEN_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Unknown | Unknown | Unknown | KITCHEN_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 6768.072 | 6768.072 | 1.306120 | 0.00014953 | 119.764 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 2.4990 | 2.534758 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 00:10:00 | 6806.97 | 6768.07 | 1.0000 | 1.54354451 | 1.306120 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.14951703 | 60.00 | 49.00 | 11.00 | 0.000 | 6806.97 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00800000 | 21.00 | 0.00800000 | 50.7558 | 0.00 | 0.00 | 6808.21 | 6808.21 | 1.54354451 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 20.93 | 14.81 | 0.00800000 | 41345.5 | |
CORRIDOR_FLR_6 VAV BOX REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORRIDOR_FLR_6 VAV BOX | CORRIDOR_FLR_6 | N/A | N/A | N/A | Yes | Yes | Yes | No | 5686.138 | 5686.138 | 0.322070 | 0.00012563 | 113.408 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 2.1006 | 2.129555 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 5721.83 | 5686.14 | 1.0000 | 0.38061603 | 0.322070 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | 0.12561546 | 60.00 | 49.00 | 11.00 | 0.000 | 5721.83 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 21.00 | 0.00780019 | 21.00 | 0.00780019 | 49.5042 | 4017.88 | 0.00 | 5723.87 | 5723.87 | 0.38061603 | 16.60 | 13.14 | 0.00800000 | 36934.7 | 31.35 | 18.46 | 0.00800000 | 51973.2 | |
VAV WITH REHEAT_COOLC | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV WITH REHEAT | BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; CORRIDOR_FLR_6; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 439146.391 | -999.000 | 20.063311 | 0.01568529 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1667 | 1004.8586 | 1.1818 | VAV WITH REHEAT_FAN | Fan:VariableVolume | 20.063311 | 23.71039277 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 67.5841 | 67.584072 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | 439146.39 | 418018.88 | 1.0000 | 23.71039277 | 20.063311 | 28.38 | 17.91 | 0.00878275 | 50947.5 | 10.94 | 10.94 | 0.00843576 | 32427.2 | 15.68369151 | 6.70 | 11.72 | 6.67 | 44954.629 | 394191.76 | 31.30 | 0.00820219 | 18.40 | 12.05026000 | 60.0612 | 23.99 | 0.00965665 | 23.99 | 0.00946970 | 49.9740 | 270719.68 | 0.00 | 494604.00 | 434248.62 | 23.71039277 | 28.38 | 18.11 | 0.00878275 | 50947.5 | 10.45 | 10.35 | 0.00777277 | 30087.2 | |
VAV WITH REHEAT_HEATC | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV WITH REHEAT | BASEMENT; RETAIL_1_FLR_1; RETAIL_2_FLR_1; MECH_FLR_1; STORAGE_FLR_1; LAUNDRY_FLR_1; CAFE_FLR_1; LOBBY_FLR_1; CORRIDOR_FLR_3; BANQUET_FLR_6; DINING_FLR_6; KITCHEN_FLR_6; CORRIDOR_FLR_6; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 92205.040 | 92205.040 | 6.018993 | 0.00203716 | 1451.965 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | VAV WITH REHEAT_FAN | Fan:VariableVolume | 20.063311 | 23.71039277 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 28.4516 | 34.532353 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 04:30:00 | 77497.57 | 92205.04 | 1.0000 | 7.11311783 | 6.018993 | 3.80 | 3.80 | 0.00505843 | 16505.0 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 2.03694989 | 60.00 | 49.00 | 11.00 | 0.000 | 77497.57 | 3.80 | 0.00505843 | 3.80 | 12.05026000 | 200.2039 | 17.50 | 0.00634051 | 21.00 | 0.00767754 | 48.7355 | 38469.32 | 0.00 | 77489.40 | 77489.40 | 7.11311783 | 16.60 | 10.13 | 0.00505843 | 29487.3 | 27.34 | 14.51 | 0.00505843 | 40381.1 | |
FLR_3_DOAS_COOLC | Coil:Cooling:Water | AirLoop | AirLoopHVAC | FLR_3_DOAS | ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; ROOM_1_FLR_6; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 47940.876 | -999.000 | 2.051199 | 0.00171234 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.0875 | 1004.8586 | 1.1818 | FLR_3_DOAS_FAN | Fan:ConstantVolume | 2.051199 | 2.42406327 | 4197.9300 | 999.8980 | 23.20619493 | 13.37 | 6.70 | 6.67 | 649777.94 | 7.3780 | 7.378040 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 47940.88 | 47940.88 | 1.0000 | 2.42406327 | 2.051199 | 31.30 | 18.40 | 0.00820219 | 52441.9 | 10.94 | 11.63 | 0.00820219 | 33570.3 | 1.71216233 | 6.70 | 11.72 | 6.67 | 2194.880 | 45746.00 | 31.30 | 0.00820219 | 18.40 | 2.05119905 | 100.0000 | 21.11 | 0.00862948 | 21.11 | 0.00863433 | 54.3544 | 138957.95 | 0.00 | 53222.24 | 50929.65 | 2.42406327 | 31.30 | 18.60 | 0.00820219 | 52441.9 | 10.70 | 10.52 | 0.00782701 | 30486.1 | |
FLR_3_DOAS_HEATC | Coil:Heating:Water | AirLoop | AirLoopHVAC | FLR_3_DOAS | ROOM_1_FLR_3; ROOM_2_FLR_3; ROOM_3_MULT19_FLR_3; ROOM_4_MULT19_FLR_3; ROOM_5_FLR_3; ROOM_6_FLR_3; ROOM_2_FLR_6; ROOM_3_MULT9_FLR_6; ROOM_1_FLR_6; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 9426.704 | 9426.704 | 0.615360 | 0.00020827 | 148.444 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | FLR_3_DOAS_FAN | Fan:ConstantVolume | 2.051199 | 2.42406327 | 4197.9300 | 999.8980 | 5.89867107 | 71.00 | 82.00 | 11.00 | 272384.29 | 2.9088 | 3.530461 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 7923.07 | 9426.70 | 1.0000 | 0.72721898 | 0.615360 | 3.80 | 3.80 | 0.00505843 | 16505.0 | 16.70 | 13.01 | 0.00800000 | 37036.7 | 0.20825026 | 60.00 | 49.00 | 11.00 | 0.000 | 7923.07 | 3.80 | 0.00505843 | 3.80 | 2.05119905 | 333.3333 | 21.11 | 0.00764533 | 21.11 | 0.00764639 | 48.2103 | 64389.54 | 0.00 | 7922.23 | 7922.23 | 0.72721898 | 16.60 | 10.13 | 0.00505843 | 29487.3 | 27.34 | 14.51 | 0.00505843 | 40381.1 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
VAV WITH REHEAT_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 20.06 | - | |||
FLR_3_DOAS_OA_CONTROLLER | DifferentialDryBulb | 2.05 | 2.05 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
BASEMENT | VAV_WITH_REHEAT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
RETAIL_1_FLR_1 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.001181 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
RETAIL_2_FLR_1 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.001181 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
LAUNDRY_FLR_1 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
CAFE_FLR_1 | VAV_WITH_REHEAT_DCV | 0.003539 | 0.000914 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
LOBBY_FLR_1 | VAV_WITH_REHEAT_DCV | 0.003539 | 0.000305 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
BANQUET_FLR_6 | VAV_WITH_REHEAT_DCV | 0.009440 | 0.003580 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
DINING_FLR_6 | VAV_WITH_REHEAT_DCV | 0.009440 | 0.003580 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
KITCHEN_FLR_6 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.003555 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
MECH_FLR_1 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
STORAGE_FLR_1 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.000609 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
CORRIDOR_FLR_3 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
CORRIDOR_FLR_6 | VAV_WITH_REHEAT_DCV | 0.000000 | 0.000305 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BASEMENT | 0.00 | 8758.33 | 0.00 |
RETAIL_1_FLR_1 | 301.00 | 8193.33 | 39.83 |
RETAIL_2_FLR_1 | 6.00 | 8709.00 | 0.00 |
LAUNDRY_FLR_1 | 4843.33 | 3205.00 | 1959.17 |
CAFE_FLR_1 | 979.00 | 7317.33 | 362.83 |
LOBBY_FLR_1 | 152.33 | 7954.33 | 17.67 |
ROOM_1_FLR_3 | 103.67 | 8535.33 | 103.67 |
ROOM_2_FLR_3 | 303.83 | 8640.83 | 303.83 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 161.17 | 8760.00 | 161.17 |
ROOM_5_FLR_3 | 114.50 | 8726.17 | 114.50 |
ROOM_6_FLR_3 | 235.50 | 8736.50 | 235.50 |
ROOM_1_FLR_6 | 255.50 | 8300.67 | 247.83 |
ROOM_2_FLR_6 | 515.17 | 8466.17 | 513.50 |
ROOM_3_MULT9_FLR_6 | 38.50 | 8311.50 | 28.33 |
BANQUET_FLR_6 | 4124.17 | 3767.00 | 692.17 |
DINING_FLR_6 | 5291.33 | 2070.17 | 571.50 |
KITCHEN_FLR_6 | 8232.83 | 6552.50 | 6311.33 |
MECH_FLR_1 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 0.00 | 0.00 | 0.00 |
Facility | 8580.00 | 8760.00 | 7235.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BASEMENT | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 3.67 | 0.00 | 3.67 | 0.00 |
RETAIL_2_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | 0.00 | 3.83 | 0.00 | 3.83 |
CAFE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 0.00 | 2.00 | 0.00 | 2.00 |
ROOM_2_FLR_3 | 0.00 | 0.50 | 0.00 | 0.50 |
ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 0.00 | 2.33 | 0.00 | 2.33 |
ROOM_6_FLR_3 | 0.00 | 0.50 | 0.00 | 0.50 |
ROOM_1_FLR_6 | 0.00 | 4.67 | 0.00 | 4.67 |
ROOM_2_FLR_6 | 0.00 | 1.17 | 0.00 | 1.17 |
ROOM_3_MULT9_FLR_6 | 0.00 | 21.00 | 0.00 | 21.00 |
BANQUET_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | 0.00 | 53.50 | 0.00 | 53.50 |
MECH_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 1.50 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 3.83 | 78.83 | 3.67 | 78.83 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 61.79 | 106.50 | 4826.41 | 1.054 | 0.000 | 0.000 | 0.000 |
RETAIL_1_FLR_1 | 6.28 | 10.83 | 265.76 | 2.377 | 0.267 | 0.000 | 0.000 |
RETAIL_2_FLR_1 | 7.28 | 12.54 | 307.76 | 1.611 | 0.048 | 0.000 | 0.000 |
LAUNDRY_FLR_1 | 4.87 | 8.40 | 309.22 | 24.839 | 0.148 | 0.000 | 0.000 |
CAFE_FLR_1 | 82.56 | 142.30 | 748.35 | 3.687 | 0.240 | 0.000 | 0.000 |
LOBBY_FLR_1 | 245.08 | 422.44 | 5183.56 | 1.873 | 0.069 | 0.000 | 0.000 |
ROOM_1_FLR_3 | 0.95 | 1.50 | 118.94 | 0.475 | 0.175 | 0.000 | 0.094 |
ROOM_2_FLR_3 | 0.95 | 1.50 | 118.93 | 0.475 | 0.175 | 0.000 | 0.093 |
ROOM_3_MULT19_FLR_3 | 1.50 | 74.75 | |||||
ROOM_4_MULT19_FLR_3 | 0.95 | 1.50 | 74.77 | 0.538 | 0.078 | 0.000 | 0.146 |
ROOM_5_FLR_3 | 0.95 | 1.50 | 118.94 | 0.475 | 0.175 | 0.000 | 0.094 |
ROOM_6_FLR_3 | 0.95 | 1.50 | 118.93 | 0.475 | 0.175 | 0.000 | 0.093 |
ROOM_1_FLR_6 | 0.95 | 1.50 | 118.94 | 0.475 | 0.175 | 0.000 | 0.106 |
ROOM_2_FLR_6 | 0.95 | 1.50 | 118.93 | 0.475 | 0.175 | 0.000 | 0.105 |
ROOM_3_MULT9_FLR_6 | 0.95 | 1.50 | 74.77 | 0.539 | 0.143 | 0.000 | 0.168 |
BANQUET_FLR_6 | 144.98 | 249.90 | 1010.89 | 4.667 | 0.051 | 0.000 | 0.000 |
DINING_FLR_6 | 144.98 | 249.90 | 1010.89 | 5.017 | 0.051 | 0.000 | 0.000 |
KITCHEN_FLR_6 | 12.90 | 22.24 | 314.87 | 20.320 | 0.146 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BASEMENT | 61.79 | 106.50 | 4826.41 | 1.031 | 0.000 | 0.000 | 0.000 |
RETAIL_1_FLR_1 | 6.28 | 10.83 | 265.76 | 2.316 | 0.006 | 0.000 | 0.000 |
RETAIL_2_FLR_1 | 7.28 | 12.54 | 307.76 | 1.571 | 0.001 | 0.000 | 0.000 |
LAUNDRY_FLR_1 | 4.87 | 8.40 | 309.22 | 22.379 | 0.003 | 0.000 | 0.000 |
CAFE_FLR_1 | 82.56 | 142.30 | 748.35 | 3.588 | 0.005 | 0.000 | 0.000 |
LOBBY_FLR_1 | 245.08 | 422.44 | 5183.56 | 1.825 | 0.002 | 0.000 | 0.000 |
ROOM_1_FLR_3 | 0.95 | 1.50 | 118.94 | 0.463 | 0.004 | 0.000 | 0.000 |
ROOM_2_FLR_3 | 0.95 | 1.50 | 118.93 | 0.462 | 0.004 | 0.000 | 0.000 |
ROOM_3_MULT19_FLR_3 | 1.50 | 74.75 | |||||
ROOM_4_MULT19_FLR_3 | 0.95 | 1.50 | 74.77 | 0.526 | 0.002 | 0.000 | 0.000 |
ROOM_5_FLR_3 | 0.95 | 1.50 | 118.94 | 0.464 | 0.004 | 0.000 | 0.000 |
ROOM_6_FLR_3 | 0.95 | 1.50 | 118.93 | 0.463 | 0.004 | 0.000 | 0.000 |
ROOM_1_FLR_6 | 0.95 | 1.50 | 118.94 | 0.463 | 0.004 | 0.000 | 0.000 |
ROOM_2_FLR_6 | 0.95 | 1.50 | 118.93 | 0.462 | 0.004 | 0.000 | 0.000 |
ROOM_3_MULT9_FLR_6 | 0.95 | 1.50 | 74.77 | 0.526 | 0.003 | 0.000 | 0.000 |
BANQUET_FLR_6 | 144.98 | 249.90 | 1010.89 | 4.340 | 0.001 | 0.000 | 0.000 |
DINING_FLR_6 | 144.98 | 249.90 | 1010.89 | 4.564 | 0.001 | 0.000 | 0.000 |
KITCHEN_FLR_6 | 12.90 | 22.24 | 314.87 | 14.839 | 0.003 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Surfaces by ClassTotal | Outdoors | |
Wall | 119 | 44 |
Floor | 25 | 0 |
Roof | 33 | 11 |
Internal Mass | 22 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 30 | 30 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 22 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
Electricity:Building | 2519.92 | 32514.46 | 03-JUN-05:00 | 155989.88 | 02-JAN-20:10 |
Electricity:Zone:BASEMENT | 320.72 | 3678.09 | 02-JAN-02:10 | 24053.66 | 02-JAN-20:10 |
InteriorLights:Electricity | 767.80 | 6681.52 | 03-JUN-05:00 | 66976.13 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:BASEMENT | 170.46 | 1548.87 | 02-JAN-02:10 | 13939.86 | 02-JAN-20:10 |
LightsWired:InteriorLights:Electricity | 767.80 | 6681.52 | 03-JUN-05:00 | 66976.13 | 02-JAN-20:10 |
Electricity:Zone:RETAIL_1_FLR_1 | 19.20 | 226.21 | 02-JAN-02:10 | 1422.43 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:RETAIL_1_FLR_1 | 9.01 | 81.87 | 02-JAN-02:10 | 736.82 | 02-JAN-20:10 |
Electricity:Zone:RETAIL_2_FLR_1 | 22.23 | 261.95 | 02-JAN-02:10 | 1647.17 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:RETAIL_2_FLR_1 | 10.43 | 94.80 | 02-JAN-02:10 | 853.24 | 02-JAN-20:10 |
Electricity:Zone:MECH_FLR_1 | 29.11 | 327.88 | 02-JAN-02:10 | 2199.85 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:MECH_FLR_1 | 16.64 | 151.16 | 02-JAN-02:10 | 1360.40 | 02-JAN-20:10 |
Electricity:Zone:STORAGE_FLR_1 | 6.91 | 81.05 | 02-JAN-02:10 | 512.82 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:STORAGE_FLR_1 | 3.31 | 30.07 | 02-JAN-02:10 | 270.66 | 02-JAN-20:10 |
Electricity:Zone:LAUNDRY_FLR_1 | 72.93 | 1008.06 | 02-JAN-02:10 | 4981.05 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:LAUNDRY_FLR_1 | 4.99 | 45.36 | 02-JAN-02:10 | 408.24 | 02-JAN-20:10 |
Electricity:Zone:CAFE_FLR_1 | 32.44 | 373.53 | 13-MAY-05:00 | 2727.18 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CAFE_FLR_1 | 18.10 | 170.32 | 13-MAY-05:00 | 1761.91 | 02-JAN-20:10 |
Electricity:Zone:LOBBY_FLR_1 | 292.74 | 3423.41 | 03-JUN-05:00 | 22119.33 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:LOBBY_FLR_1 | 143.73 | 1312.00 | 03-JUN-05:00 | 12090.12 | 02-JAN-20:10 |
Electricity:Zone:ROOM_1_FLR_3 | 17.98 | 253.36 | 01-JAN-02:10 | 1306.07 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_1_FLR_3 | 5.69 | 35.53 | 01-JAN-11:10 | 568.55 | 01-JAN-19:10 |
Electricity:Zone:ROOM_2_FLR_3 | 17.98 | 253.33 | 01-JAN-02:10 | 1305.92 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_2_FLR_3 | 5.69 | 35.53 | 01-JAN-11:10 | 568.49 | 01-JAN-19:10 |
Electricity:Zone:ROOM_3_MULT19_FLR_3 | 296.68 | 4430.63 | 01-JAN-02:10 | 21465.35 | 01-JAN-08:10 |
InteriorLights:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 67.93 | 424.31 | 01-JAN-11:10 | 6788.95 | 01-JAN-19:10 |
Electricity:Zone:ROOM_4_MULT19_FLR_3 | 296.76 | 4431.84 | 01-JAN-02:10 | 21471.23 | 01-JAN-08:10 |
InteriorLights:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 67.94 | 424.43 | 01-JAN-11:10 | 6790.81 | 01-JAN-19:10 |
Electricity:Zone:ROOM_5_FLR_3 | 17.98 | 253.36 | 01-JAN-02:10 | 1306.07 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_5_FLR_3 | 5.69 | 35.53 | 01-JAN-11:10 | 568.55 | 01-JAN-19:10 |
Electricity:Zone:ROOM_6_FLR_3 | 17.98 | 253.33 | 01-JAN-02:10 | 1305.92 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_6_FLR_3 | 5.69 | 35.53 | 01-JAN-11:10 | 568.49 | 01-JAN-19:10 |
Electricity:Zone:CORRIDOR_FLR_3 | 109.61 | 995.90 | 02-JAN-02:10 | 8963.14 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CORRIDOR_FLR_3 | 109.61 | 995.90 | 02-JAN-02:10 | 8963.14 | 02-JAN-20:10 |
Electricity:Zone:ROOM_1_FLR_6 | 4.50 | 63.34 | 01-JAN-02:10 | 326.52 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_1_FLR_6 | 1.42 | 8.88 | 01-JAN-11:10 | 142.14 | 01-JAN-19:10 |
Electricity:Zone:ROOM_2_FLR_6 | 4.49 | 63.33 | 01-JAN-02:10 | 326.48 | 01-JAN-21:10 |
InteriorLights:Electricity:Zone:ROOM_2_FLR_6 | 1.42 | 8.88 | 01-JAN-11:10 | 142.12 | 01-JAN-19:10 |
Electricity:Zone:ROOM_3_MULT9_FLR_6 | 35.14 | 524.82 | 01-JAN-02:10 | 2542.65 | 01-JAN-08:10 |
InteriorLights:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 8.05 | 50.26 | 01-JAN-11:10 | 804.17 | 01-JAN-19:10 |
Electricity:Zone:BANQUET_FLR_6 | 210.70 | 2547.25 | 03-JUN-05:00 | 9841.96 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:BANQUET_FLR_6 | 34.84 | 297.95 | 03-JUN-05:00 | 3094.06 | 02-JAN-20:10 |
Electricity:Zone:DINING_FLR_6 | 210.70 | 2547.25 | 03-JUN-05:00 | 9841.96 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:DINING_FLR_6 | 34.84 | 297.95 | 03-JUN-05:00 | 3094.06 | 02-JAN-20:10 |
Electricity:Zone:KITCHEN_FLR_6 | 454.16 | 6253.02 | 02-JAN-02:10 | 18944.06 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:KITCHEN_FLR_6 | 13.33 | 121.09 | 02-JAN-02:10 | 1089.83 | 02-JAN-20:10 |
Electricity:Zone:CORRIDOR_FLR_6 | 29.00 | 263.50 | 02-JAN-02:10 | 2371.52 | 02-JAN-20:10 |
InteriorLights:Electricity:Zone:CORRIDOR_FLR_6 | 29.00 | 263.50 | 02-JAN-02:10 | 2371.52 | 02-JAN-20:10 |
InteriorEquipment:Electricity | 1745.02 | 25691.80 | 02-JAN-02:10 | 89475.41 | 02-JAN-07:10 |
InteriorEquipment:Electricity:Zone:BASEMENT | 150.26 | 2129.22 | 02-JAN-02:10 | 10113.80 | 02-JAN-20:10 |
MiscPlug:InteriorEquipment:Electricity | 959.57 | 15202.41 | 02-JAN-02:10 | 59492.27 | 02-JAN-07:10 |
InteriorEquipment:Electricity:Zone:RETAIL_1_FLR_1 | 10.19 | 144.34 | 02-JAN-02:10 | 685.60 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:RETAIL_2_FLR_1 | 11.80 | 167.14 | 02-JAN-02:10 | 793.93 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:MECH_FLR_1 | 12.47 | 176.73 | 02-JAN-02:10 | 839.45 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:STORAGE_FLR_1 | 3.60 | 50.98 | 02-JAN-02:10 | 242.16 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:LAUNDRY_FLR_1 | 67.94 | 962.69 | 02-JAN-02:10 | 4572.80 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:CAFE_FLR_1 | 14.34 | 203.22 | 02-JAN-02:10 | 965.27 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:LOBBY_FLR_1 | 149.00 | 2111.41 | 02-JAN-02:10 | 10029.21 | 02-JAN-20:10 |
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 228.75 | 3921.46 | 01-JAN-00:10 | 17646.57 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 228.82 | 3922.53 | 01-JAN-00:10 | 17651.40 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_5_FLR_3 | 12.29 | 210.72 | 01-JAN-00:10 | 948.23 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_6_FLR_3 | 12.29 | 210.69 | 01-JAN-00:10 | 948.12 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_1_FLR_6 | 3.07 | 52.68 | 01-JAN-00:10 | 237.06 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_2_FLR_6 | 3.07 | 52.67 | 01-JAN-00:10 | 237.03 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 27.10 | 464.51 | 01-JAN-00:10 | 2090.30 | 01-JAN-08:10 |
InteriorEquipment:Electricity:Zone:BANQUET_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
Cooking:InteriorEquipment:Electricity | 762.04 | 9746.88 | 01-JAN-00:10 | 29240.64 | 01-JAN-07:10 |
InteriorEquipment:Electricity:Zone:DINING_FLR_6 | 175.86 | 2249.30 | 01-JAN-00:10 | 6747.90 | 01-JAN-07:10 |
InteriorEquipment:Electricity:Zone:KITCHEN_FLR_6 | 433.74 | 5990.78 | 01-JAN-00:10 | 16487.34 | 01-JAN-07:10 |
ReachInFreezer:InteriorEquipment:Electricity | 14.43 | 457.50 | 01-JAN-00:10 | 457.50 | 01-JAN-00:10 |
ReachInRefrigerator:InteriorEquipment:Electricity | 8.99 | 285.00 | 01-JAN-00:10 | 285.00 | 01-JAN-00:10 |
Refrigeration:Electricity | 61.97 | 1111.64 | 06-JAN-23:30 | 3259.62 | 04-APR-07:20 |
Refrigeration:Electricity:Zone:KITCHEN_FLR_6 | 7.09 | 88.82 | 02-JAN-11:30 | 2093.44 | 01-JAN-11:10 |
General:Refrigeration:Electricity | 7.09 | 88.82 | 02-JAN-11:30 | 2093.44 | 01-JAN-11:10 |
Electricity:Plant | 1281.49 | 3295.14 | 07-FEB-03:50 | 193686.03 | 16-OCT-11:00 |
LowTempRefrigeration:Refrigeration:Electricity | 20.34 | 0.00 | 01-JAN-11:10 | 1913.54 | 02-DEC-11:50 |
MedTempRefrigeration:Refrigeration:Electricity | 34.53 | 927.79 | 29-DEC-03:10 | 1196.19 | 12-FEB-15:00 |
WaterSystems:Electricity | 90.76 | 1086.74 | 13-MAY-00:40 | 4739.51 | 30-MAR-06:10 |
Water Heater:WaterSystems:Electricity | 90.76 | 1086.74 | 13-MAY-00:40 | 4739.51 | 30-MAR-06:10 |
Fans:Electricity | 560.82 | 14595.12 | 27-AUG-05:10 | 26465.09 | 02-FEB-21:20 |
Fans:Electricity:Zone:ROOM_1_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Ventilation (simple):Fans:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_2_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_4_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_5_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_6_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_1_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_2_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Fans:Electricity:Zone:ROOM_3_MULT9_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Electricity:HVAC | 593.29 | 15456.14 | 27-AUG-05:10 | 28329.61 | 02-FEB-21:20 |
ExteriorEquipment:Electricity | 982.92 | 6683.63 | 02-JAN-02:20 | 63148.16 | 18-JAN-07:20 |
Transformer:ExteriorEquipment:Electricity | 32.47 | 553.73 | 27-MAY-05:00 | 1873.65 | 02-JAN-21:10 |
ElectricityPurchased:Facility | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
ElectricityPurchased:Plant | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
Cogeneration:ElectricityPurchased | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
ElectricityNet:Plant | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
Cogeneration:ElectricityNet | 5571.92 | 72624.30 | 15-MAY-01:50 | 367340.34 | 29-SEP-19:10 |
General:Fans:Electricity | 560.82 | 14595.12 | 27-AUG-05:10 | 26465.09 | 02-FEB-21:20 |
ExteriorLights:Electricity | 226.76 | 0.00 | 01-JAN-07:00 | 14423.55 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 226.76 | 0.00 | 01-JAN-07:00 | 14423.55 | 01-JAN-00:10 |
ElevatorLift:ExteriorEquipment:Electricity | 947.54 | 6111.10 | 01-JAN-00:10 | 61110.99 | 01-JAN-07:10 |
ElevatorLightsFan:ExteriorEquipment:Electricity | 2.91 | 18.79 | 01-JAN-00:10 | 187.95 | 01-JAN-07:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 1005.13 | 0.00 | 01-JAN-00:10 | 182724.56 | 16-OCT-11:00 |
General:Cooling:Electricity | 1005.13 | 0.00 | 01-JAN-00:10 | 182724.56 | 16-OCT-11:00 |
Pumps:Electricity | 130.74 | 87.09 | 06-APR-17:40 | 6680.13 | 29-SEP-15:20 |
General:Pumps:Electricity | 130.74 | 87.09 | 06-APR-17:40 | 6680.13 | 29-SEP-15:20 |
WIRED_LTG_ELECTRICITY | 27.03 | 0.00 | 01-JAN-00:10 | 2357.56 | 02-JAN-20:20 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 4790.50 | 32853.80 | 01-NOV-00:10 | 418589.45 | 11-JAN-18:40 |
Gas:Building | 1788.85 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
Gas:Zone:LAUNDRY_FLR_1 | 590.21 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
InteriorEquipment:Gas | 1788.85 | 13361.90 | 02-JAN-02:10 | 104248.32 | 02-JAN-18:10 |
InteriorEquipment:Gas:Zone:LAUNDRY_FLR_1 | 590.21 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
Laundry:InteriorEquipment:Gas | 590.21 | 8363.49 | 02-JAN-02:10 | 39726.58 | 02-JAN-20:10 |
Gas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
InteriorEquipment:Gas:Zone:KITCHEN_FLR_6 | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Cooking:InteriorEquipment:Gas | 1198.64 | 4998.41 | 01-JAN-00:10 | 74976.11 | 01-JAN-16:10 |
Gas:Plant | 3001.64 | 15908.90 | 21-JAN-09:50 | 323188.81 | 29-MAR-22:50 |
WaterSystems:Gas | 2038.30 | 15908.90 | 15-JAN-16:10 | 175037.60 | 02-FEB-22:00 |
Water Heater:WaterSystems:Gas | 2038.30 | 15908.90 | 15-JAN-16:10 | 175037.60 | 02-FEB-22:00 |
Heating:Gas | 963.34 | 0.00 | 14-JAN-19:20 | 214982.90 | 08-JAN-07:00 |
Boiler:Heating:Gas | 963.34 | 0.00 | 14-JAN-19:20 | 214982.90 | 08-JAN-07:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopCoolingDemand:Facility | 3453.35 | 0.00 | 01-JAN-00:10 | 567565.81 | 18-AUG-15:10 |
PlantLoopCoolingDemand:HVAC | 3453.35 | 0.00 | 01-JAN-00:10 | 567565.81 | 18-AUG-15:10 |
CoolingCoils:PlantLoopCoolingDemand | 3453.35 | 0.00 | 01-JAN-00:10 | 567565.81 | 18-AUG-15:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 22864.31 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
Water:Plant | 22864.31 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
WaterSystems:Water | 22864.31 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
Water Heater:WaterSystems:Water | 18749.60 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-19:10 |
MainsWater:Facility | 22864.31 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
MainsWater:Plant | 22864.31 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
WaterSystems:MainsWater | 22864.31 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-21:10 |
Water Heater:WaterSystems:MainsWater | 18749.60 | 0.00 | 02-JAN-01:10 | 0.00 | 02-JAN-19:10 |
WaterUse:WaterSystems:Water | 4114.71 | 0.00 | 02-JAN-01:10 | 0.00 | 03-JAN-07:20 |
WaterUse:WaterSystems:MainsWater | 4114.71 | 0.00 | 02-JAN-01:10 | 0.00 | 03-JAN-07:20 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 18802.15 | 157070.51 | 31-MAR-10:20 | 2139495.95 | 18-AUG-15:10 |
EnergyTransfer:Building | 5142.21 | 101726.97 | 29-MAR-12:10 | 282003.21 | 16-OCT-15:10 |
EnergyTransfer:Zone:KITCHEN_FLR_6 | 734.15 | 12093.01 | 07-JAN-03:20 | 34804.69 | 15-OCT-10:40 |
Refrigeration:EnergyTransfer | 184.27 | 3941.10 | 29-DEC-03:10 | 10335.50 | 08-SEP-06:30 |
Refrigeration:EnergyTransfer:Zone:KITCHEN_FLR_6 | 92.13 | 1970.55 | 29-DEC-03:10 | 5167.75 | 08-SEP-06:30 |
EnergyTransfer:Plant | 9549.73 | 24150.70 | 28-FEB-15:20 | 1317769.46 | 18-AUG-15:10 |
LowTempRefrigeration:Refrigeration:EnergyTransfer | 21.64 | 0.00 | 01-JAN-11:10 | 2686.44 | 01-JAN-11:40 |
MedTempRefrigeration:Refrigeration:EnergyTransfer | 70.49 | 1733.38 | 29-DEC-03:10 | 2538.56 | 12-FEB-15:00 |
PlantLoopHeatingDemand:Facility | 1340.09 | 10179.81 | 01-OCT-00:10 | 197303.81 | 08-JAN-07:00 |
PlantLoopHeatingDemand:Plant | 683.24 | 8686.79 | 28-AUG-00:10 | 47545.11 | 03-FEB-07:50 |
WaterSystems:PlantLoopHeatingDemand | 683.24 | 8686.79 | 28-AUG-00:10 | 47545.11 | 03-FEB-07:50 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Zone:BASEMENT | 423.36 | 10243.47 | 29-MAR-13:40 | 22827.97 | 08-JAN-07:00 |
Heating:EnergyTransfer | 11.23 | 0.00 | 01-JAN-08:10 | 15660.61 | 29-MAR-08:10 |
Heating:EnergyTransfer:Zone:BASEMENT | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer | 5038.84 | 98805.45 | 29-MAR-12:10 | 279459.73 | 16-OCT-15:10 |
Cooling:EnergyTransfer:Zone:BASEMENT | 423.36 | 10243.47 | 29-MAR-13:40 | 22827.97 | 08-JAN-07:00 |
EnergyTransfer:Zone:RETAIL_1_FLR_1 | 43.08 | 0.05 | 13-DEC-04:00 | 3685.50 | 16-OCT-12:10 |
Heating:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 196.88 | 30-MAR-07:00 |
Cooling:EnergyTransfer:Zone:RETAIL_1_FLR_1 | 43.08 | 0.00 | 07-MAR-05:30 | 3685.50 | 16-OCT-12:10 |
EnergyTransfer:Zone:RETAIL_2_FLR_1 | 41.36 | 731.21 | 29-MAR-12:10 | 1815.08 | 06-JAN-23:00 |
Heating:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:RETAIL_2_FLR_1 | 41.36 | 731.21 | 29-MAR-12:10 | 1815.08 | 06-JAN-23:00 |
EnergyTransfer:Zone:MECH_FLR_1 | 34.07 | 339.46 | 30-MAR-05:00 | 1482.17 | 06-JAN-23:00 |
Heating:EnergyTransfer:Zone:MECH_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:MECH_FLR_1 | 34.07 | 339.46 | 30-MAR-05:00 | 1482.17 | 06-JAN-23:00 |
EnergyTransfer:Zone:STORAGE_FLR_1 | 15.07 | 22.83 | 30-MAR-06:00 | 657.52 | 06-JAN-23:00 |
Heating:EnergyTransfer:Zone:STORAGE_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:STORAGE_FLR_1 | 15.07 | 22.83 | 30-MAR-06:00 | 657.52 | 06-JAN-23:00 |
EnergyTransfer:Zone:LAUNDRY_FLR_1 | 612.75 | 10054.58 | 10-JAN-05:00 | 38066.93 | 29-SEP-20:00 |
Heating:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:LAUNDRY_FLR_1 | 612.75 | 10054.58 | 10-JAN-05:00 | 38066.93 | 29-SEP-20:00 |
EnergyTransfer:Zone:CAFE_FLR_1 | 236.11 | 1918.63 | 29-MAR-12:10 | 13362.05 | 19-NOV-11:00 |
Heating:EnergyTransfer:Zone:CAFE_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:CAFE_FLR_1 | 236.11 | 1918.63 | 29-MAR-12:10 | 13362.05 | 19-NOV-11:00 |
EnergyTransfer:Zone:LOBBY_FLR_1 | 847.08 | 15716.16 | 29-MAR-12:10 | 37167.48 | 03-JAN-02:00 |
Heating:EnergyTransfer:Zone:LOBBY_FLR_1 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:LOBBY_FLR_1 | 847.08 | 15716.16 | 29-MAR-12:10 | 37167.48 | 03-JAN-02:00 |
EnergyTransfer:Zone:ROOM_1_FLR_3 | 40.66 | 0.04 | 22-MAR-02:30 | 9967.17 | 15-OCT-15:10 |
Heating:EnergyTransfer:Zone:ROOM_1_FLR_3 | 1.28 | 0.00 | 01-JAN-08:10 | 2322.97 | 29-MAR-08:10 |
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_3 | 39.37 | 0.00 | 01-JAN-00:10 | 9967.17 | 15-OCT-15:10 |
EnergyTransfer:Zone:ROOM_2_FLR_3 | 33.94 | 0.01 | 31-OCT-04:30 | 8635.29 | 16-OCT-15:10 |
Heating:EnergyTransfer:Zone:ROOM_2_FLR_3 | 2.49 | 0.00 | 01-JAN-08:10 | 2509.56 | 30-MAR-08:10 |
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_3 | 31.45 | 0.00 | 01-JAN-00:10 | 8635.29 | 16-OCT-15:10 |
EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 364.12 | 4476.51 | 30-MAR-08:40 | 51371.24 | 16-OCT-12:10 |
Heating:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:ROOM_3_MULT19_FLR_3 | 364.12 | 4476.51 | 30-MAR-08:40 | 51371.24 | 16-OCT-12:10 |
EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 379.54 | 1.12 | 30-MAR-02:10 | 47009.12 | 19-JUL-15:10 |
Heating:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 0.60 | 0.00 | 01-JAN-00:10 | 9316.76 | 03-JAN-16:10 |
Cooling:EnergyTransfer:Zone:ROOM_4_MULT19_FLR_3 | 378.94 | 0.00 | 03-JAN-03:50 | 47009.12 | 19-JUL-15:10 |
EnergyTransfer:Zone:ROOM_5_FLR_3 | 37.61 | 0.00 | 21-MAR-02:50 | 8282.80 | 15-OCT-08:10 |
Heating:EnergyTransfer:Zone:ROOM_5_FLR_3 | 1.45 | 0.00 | 01-JAN-07:20 | 1999.17 | 30-MAR-04:00 |
Cooling:EnergyTransfer:Zone:ROOM_5_FLR_3 | 36.16 | 0.00 | 01-JAN-00:10 | 8282.80 | 15-OCT-08:10 |
EnergyTransfer:Zone:ROOM_6_FLR_3 | 31.45 | 0.01 | 07-MAY-04:20 | 7466.46 | 15-OCT-08:10 |
Heating:EnergyTransfer:Zone:ROOM_6_FLR_3 | 2.75 | 0.00 | 01-JAN-07:20 | 2126.78 | 29-MAR-18:10 |
Cooling:EnergyTransfer:Zone:ROOM_6_FLR_3 | 28.70 | 0.00 | 01-JAN-00:10 | 7466.46 | 15-OCT-08:10 |
EnergyTransfer:Zone:CORRIDOR_FLR_3 | 135.22 | 0.06 | 11-FEB-05:20 | 7439.85 | 16-OCT-13:50 |
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 0.01 | 0.00 | 01-JAN-00:10 | 596.32 | 30-MAR-08:00 |
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_3 | 135.21 | 0.00 | 01-JAN-04:50 | 7439.85 | 16-OCT-13:50 |
EnergyTransfer:Zone:ROOM_1_FLR_6 | 11.20 | 0.00 | 16-NOV-01:40 | 2707.45 | 15-OCT-15:10 |
Heating:EnergyTransfer:Zone:ROOM_1_FLR_6 | 0.76 | 0.00 | 01-JAN-08:10 | 755.31 | 30-MAR-08:10 |
Cooling:EnergyTransfer:Zone:ROOM_1_FLR_6 | 10.44 | 0.00 | 01-JAN-00:10 | 2707.45 | 15-OCT-15:10 |
EnergyTransfer:Zone:ROOM_2_FLR_6 | 9.70 | 0.01 | 02-FEB-02:20 | 2418.02 | 16-OCT-15:10 |
Heating:EnergyTransfer:Zone:ROOM_2_FLR_6 | 1.32 | 0.00 | 01-JAN-08:10 | 786.56 | 30-MAR-08:10 |
Cooling:EnergyTransfer:Zone:ROOM_2_FLR_6 | 8.39 | 0.00 | 01-JAN-00:10 | 2418.02 | 16-OCT-15:10 |
EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 75.81 | 0.43 | 08-NOV-06:00 | 12473.98 | 16-OCT-15:10 |
Heating:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 0.55 | 0.00 | 01-JAN-07:20 | 2489.52 | 30-MAR-08:10 |
Cooling:EnergyTransfer:Zone:ROOM_3_MULT9_FLR_6 | 75.26 | 0.00 | 01-JAN-00:10 | 12473.98 | 16-OCT-15:10 |
EnergyTransfer:Zone:BANQUET_FLR_6 | 454.70 | 9650.43 | 29-MAR-11:50 | 20428.82 | 29-SEP-22:00 |
Heating:EnergyTransfer:Zone:BANQUET_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:BANQUET_FLR_6 | 454.70 | 9650.43 | 29-MAR-11:50 | 20428.82 | 29-SEP-22:00 |
EnergyTransfer:Zone:DINING_FLR_6 | 496.54 | 10716.97 | 29-MAR-11:50 | 22120.83 | 29-SEP-21:10 |
Heating:EnergyTransfer:Zone:DINING_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:DINING_FLR_6 | 496.54 | 10716.97 | 29-MAR-11:50 | 22120.83 | 29-SEP-21:10 |
Heating:EnergyTransfer:Zone:KITCHEN_FLR_6 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:KITCHEN_FLR_6 | 642.02 | 10047.00 | 07-JAN-03:20 | 29810.50 | 15-OCT-10:40 |
EnergyTransfer:Zone:CORRIDOR_FLR_6 | 84.66 | 0.54 | 30-MAR-03:20 | 4056.92 | 16-OCT-13:20 |
Heating:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 0.01 | 0.00 | 01-JAN-00:10 | 518.77 | 07-MAR-05:50 |
Cooling:EnergyTransfer:Zone:CORRIDOR_FLR_6 | 84.65 | 0.00 | 03-JAN-02:50 | 4056.92 | 16-OCT-13:20 |
WaterSystems:EnergyTransfer | 683.24 | 8686.79 | 28-AUG-00:10 | 47545.11 | 03-FEB-07:50 |
WaterUse:WaterSystems:EnergyTransfer | 683.24 | 8686.79 | 28-AUG-00:10 | 47545.11 | 03-FEB-07:50 |
EnergyTransfer:HVAC | 4110.21 | 3864.26 | 06-APR-17:40 | 570150.37 | 18-AUG-15:10 |
HeatingCoils:EnergyTransfer | 656.85 | 0.00 | 14-JAN-19:20 | 170916.71 | 08-JAN-07:00 |
PlantLoopHeatingDemand:HVAC | 656.85 | 0.00 | 14-JAN-19:20 | 170916.71 | 08-JAN-07:00 |
HeatingCoils:PlantLoopHeatingDemand | 656.85 | 0.00 | 14-JAN-19:20 | 170916.71 | 08-JAN-07:00 |
CoolingCoils:EnergyTransfer | 3453.35 | 0.00 | 01-JAN-00:10 | 567565.81 | 18-AUG-15:10 |
Boilers:EnergyTransfer | 649.26 | 0.00 | 14-JAN-19:20 | 169852.34 | 08-JAN-07:00 |
Chillers:EnergyTransfer | 3559.98 | 0.00 | 01-JAN-00:10 | 573841.70 | 18-AUG-15:10 |
HeatRejection:EnergyTransfer | 4565.11 | 0.00 | 01-JAN-00:10 | 724787.36 | 18-AUG-15:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BASEMENT | 0.000 | 0.000 | 0.000 | -423.362 | 0.000 | 0.000 | 149.742 | 170.465 | 150.259 | 0.000 | 0.000 | 0.000 | 0.004 | 0.000 | 0.000 | 0.000 | 0.000 | -47.104 |
RETAIL_1_FLR_1 | 0.000 | 0.000 | 0.002 | -43.078 | 0.000 | 0.000 | 15.901 | 9.010 | 10.186 | 18.980 | 0.000 | 0.169 | 1.045 | 0.000 | -7.987 | 0.000 | -4.229 | -0.000 |
RETAIL_2_FLR_1 | 0.000 | 0.000 | 0.000 | -41.364 | 0.000 | 0.000 | 17.545 | 10.434 | 11.795 | 0.000 | 0.000 | 0.042 | 2.534 | 0.000 | 0.000 | 0.000 | -0.986 | -0.000 |
LAUNDRY_FLR_1 | 0.000 | 0.000 | 0.000 | -612.749 | 0.000 | 0.000 | 11.779 | 4.992 | 658.148 | 0.000 | 0.000 | 0.151 | 0.000 | 0.000 | 0.000 | 0.000 | -3.059 | -59.263 |
CAFE_FLR_1 | 0.000 | 0.000 | 0.000 | -236.115 | 0.000 | 0.000 | 195.817 | 18.100 | 14.341 | 52.487 | 0.000 | 0.418 | 0.001 | 0.000 | -24.905 | 0.000 | -12.308 | -7.833 |
LOBBY_FLR_1 | 0.000 | 0.000 | 0.000 | -847.080 | 0.000 | 0.000 | 575.935 | 143.734 | 149.002 | 69.920 | 0.000 | 0.947 | 0.000 | 0.000 | -33.238 | 0.000 | -24.976 | -34.244 |
ROOM_1_FLR_3 | 1.283 | -22.695 | 0.000 | -16.678 | 0.000 | 0.000 | 9.694 | 5.689 | 12.292 | 39.973 | 0.000 | 0.229 | 0.000 | 0.000 | -18.120 | 0.000 | -6.551 | -5.116 |
ROOM_2_FLR_3 | 2.489 | -15.074 | 0.000 | -16.376 | 0.000 | 0.000 | 9.724 | 5.688 | 12.291 | 29.411 | 0.000 | 0.249 | 0.000 | 0.000 | -18.159 | 0.000 | -6.422 | -3.820 |
ROOM_3_MULT19_FLR_3 | 0.000 | -99.024 | 0.000 | -265.099 | 0.000 | 0.000 | 0.000 | 67.926 | 228.754 | 220.847 | 0.000 | 0.789 | 34.882 | 0.000 | -112.892 | 0.000 | -76.183 | -0.001 |
ROOM_4_MULT19_FLR_3 | 0.600 | -160.874 | 0.000 | -218.067 | 0.000 | 0.000 | 185.324 | 67.944 | 228.817 | 61.803 | 0.000 | 2.619 | 0.000 | 0.000 | -97.763 | 0.000 | -53.230 | -17.172 |
ROOM_5_FLR_3 | 1.451 | -19.387 | 0.000 | -16.772 | 0.000 | 0.000 | 9.687 | 5.689 | 12.292 | 36.804 | 0.000 | 0.218 | 0.000 | 0.000 | -17.625 | 0.000 | -6.579 | -5.777 |
ROOM_6_FLR_3 | 2.753 | -12.286 | 0.000 | -16.414 | 0.000 | 0.000 | 9.724 | 5.688 | 12.291 | 25.960 | 0.000 | 0.235 | 0.000 | 0.000 | -17.317 | 0.000 | -6.425 | -4.208 |
ROOM_1_FLR_6 | 0.760 | -6.254 | 0.000 | -4.184 | 0.000 | 0.000 | 2.422 | 1.422 | 3.073 | 9.833 | 0.000 | 0.056 | 0.000 | 0.000 | -4.529 | 0.000 | -1.702 | -0.898 |
ROOM_2_FLR_6 | 1.318 | -4.276 | 0.000 | -4.111 | 0.000 | 0.000 | 2.430 | 1.422 | 3.073 | 7.213 | 0.000 | 0.060 | 0.000 | 0.000 | -4.523 | 0.000 | -1.667 | -0.938 |
ROOM_3_MULT9_FLR_6 | 0.553 | -48.204 | 0.000 | -27.056 | 0.000 | 0.000 | 21.776 | 8.046 | 27.097 | 48.498 | 0.000 | 0.345 | 0.000 | 0.000 | -21.267 | 0.000 | -9.717 | -0.072 |
BANQUET_FLR_6 | 0.000 | 0.000 | 0.000 | -454.703 | 0.000 | 0.000 | 322.130 | 34.838 | 175.857 | 5.641 | 0.000 | 0.083 | 0.000 | 0.000 | -14.265 | 0.000 | -4.040 | -65.542 |
DINING_FLR_6 | 0.000 | 0.000 | 0.000 | -496.538 | 0.000 | 0.000 | 319.981 | 34.838 | 175.857 | 5.230 | 0.000 | 0.073 | 0.000 | 0.000 | -14.884 | 0.000 | -4.114 | -20.443 |
KITCHEN_FLR_6 | 0.000 | 0.000 | 0.000 | -642.002 | 0.000 | 0.000 | 29.014 | 13.327 | 550.372 | 16.560 | 0.000 | 0.037 | 46.747 | 0.000 | -10.341 | 0.000 | -3.715 | 0.000 |
MECH_FLR_1 | 0.000 | 0.000 | 0.000 | -34.075 | 0.000 | 0.000 | 0.000 | 16.636 | 12.472 | 0.000 | 0.000 | 0.101 | 6.826 | 0.000 | 0.000 | 0.000 | -1.960 | -0.000 |
STORAGE_FLR_1 | 0.000 | 0.000 | 0.000 | -15.074 | 0.000 | 0.000 | 0.000 | 3.310 | 3.598 | 0.000 | 0.000 | 0.070 | 9.423 | 0.000 | 0.000 | 0.000 | -1.327 | 0.000 |
CORRIDOR_FLR_3 | 0.000 | 0.000 | 0.009 | -135.208 | 0.000 | 0.000 | 0.000 | 109.607 | 0.000 | 33.953 | 0.000 | 0.334 | 18.146 | 0.000 | -21.132 | 0.000 | -5.709 | -0.001 |
CORRIDOR_FLR_6 | 0.000 | 0.000 | 0.011 | -84.652 | 0.000 | 0.000 | 0.000 | 29.000 | 0.000 | 16.062 | 0.000 | 0.092 | 52.207 | 0.000 | -10.035 | 0.000 | -2.684 | 0.000 |
Total Facility | 11.207 | -388.073 | 0.022 | -4650.756 | 0.000 | 0.000 | 1888.625 | 767.804 | 2451.865 | 699.175 | 0.000 | 7.314 | 171.816 | 0.000 | -448.982 | 0.000 | -237.584 | -272.430 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | -22824.48 | 0.00 | 0.00 | 5967.52 | 4646.62 | 4258.44 | 0.00 | 0.00 | 0.00 | 7951.90 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 16-OCT-12:10 | 0.00 | 0.00 | 0.00 | -3685.54 | 0.00 | 0.00 | 150.60 | 204.67 | 252.59 | 4596.26 | 0.00 | 255.29 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1773.87 |
RETAIL_2_FLR_1 | 06-JAN-23:00 | 0.00 | 0.00 | 0.00 | -1815.09 | 0.00 | 0.00 | 848.55 | 568.83 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -90.56 | -96.73 |
LAUNDRY_FLR_1 | 29-SEP-20:00 | 0.00 | 0.00 | 0.00 | -38066.89 | 0.00 | 0.00 | 408.88 | 408.24 | 44299.38 | 0.00 | 0.00 | 14.53 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -7064.14 |
CAFE_FLR_1 | 19-NOV-11:00 | 0.00 | 0.00 | 0.00 | -13366.92 | 0.00 | 0.00 | 4947.96 | 358.25 | 406.43 | 13481.46 | 0.00 | 114.07 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -5941.25 |
LOBBY_FLR_1 | 03-JAN-01:55 | 0.00 | 0.00 | 0.00 | -37276.01 | 0.00 | 0.00 | 30758.70 | 2015.02 | 2639.27 | 0.00 | 0.00 | 0.00 | 7877.74 | 0.00 | -3738.87 | 0.00 | -2275.84 | 0.00 |
ROOM_1_FLR_3 | 15-OCT-15:02 | 0.00 | -10435.72 | 0.00 | -743.65 | 0.00 | 0.00 | 130.71 | 35.53 | 305.54 | 8334.52 | 0.00 | 207.59 | 2165.48 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_3 | 16-OCT-15:02 | 0.00 | -10097.99 | 0.00 | -737.18 | 0.00 | 0.00 | 235.28 | 45.48 | 273.90 | 6562.75 | 0.00 | 184.29 | 3533.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT19_FLR_3 | 16-OCT-12:10 | 0.00 | -40811.61 | 0.00 | -10562.96 | 0.00 | 0.00 | 0.00 | 424.31 | 5097.90 | 56001.20 | 0.00 | 1676.46 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -11825.29 |
ROOM_4_MULT19_FLR_3 | 15-OCT-08:62 | 0.00 | -58841.56 | 0.00 | -9688.58 | 0.00 | 0.00 | 2545.84 | 1584.52 | 12159.85 | 7507.36 | 0.00 | 995.55 | 43737.01 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_5_FLR_3 | 15-OCT-08:62 | 0.00 | -9028.01 | 0.00 | -741.87 | 0.00 | 0.00 | 130.71 | 132.66 | 653.23 | 8248.03 | 0.00 | 178.40 | 426.86 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_6_FLR_3 | 15-OCT-08:62 | 0.00 | -8888.71 | 0.00 | -737.89 | 0.00 | 0.00 | 130.71 | 132.65 | 653.15 | 6854.19 | 0.00 | 179.82 | 1676.06 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_6 | 15-OCT-15:02 | 0.00 | -2711.49 | 0.00 | -187.02 | 0.00 | 0.00 | 32.68 | 8.88 | 76.39 | 2063.80 | 0.00 | 51.14 | 665.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_2_FLR_6 | 16-OCT-15:02 | 0.00 | -2622.06 | 0.00 | -185.25 | 0.00 | 0.00 | 58.82 | 11.37 | 68.48 | 1624.27 | 0.00 | 45.35 | 999.03 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ROOM_3_MULT9_FLR_6 | 16-OCT-15:02 | 0.00 | -11941.22 | 0.00 | -1214.07 | 0.00 | 0.00 | 529.39 | 64.33 | 603.86 | 5153.78 | 0.00 | 202.77 | 6601.15 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
BANQUET_FLR_6 | 29-SEP-22:00 | 0.00 | 0.00 | 0.00 | -20429.77 | 0.00 | 0.00 | 15646.27 | 2062.71 | 6747.90 | 0.00 | 0.00 | 6.53 | 0.00 | 0.00 | -209.55 | 0.00 | 0.00 | -3824.08 |
DINING_FLR_6 | 29-SEP-21:10 | 0.00 | 0.00 | 0.00 | -22123.69 | 0.00 | 0.00 | 15645.33 | 2062.71 | 6747.90 | 0.00 | 0.00 | 7.87 | 0.00 | 0.00 | -227.85 | 0.00 | 0.00 | -2112.27 |
KITCHEN_FLR_6 | 15-OCT-10:35 | 0.00 | 0.00 | 0.00 | -29810.02 | 0.00 | 0.00 | 464.32 | 363.28 | 24259.91 | 2133.36 | 0.00 | 108.00 | 2481.15 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | 06-JAN-23:00 | 0.00 | 0.00 | 0.00 | -1482.10 | 0.00 | 0.00 | 0.00 | 906.93 | 618.54 | 0.00 | 0.00 | 0.00 | 142.24 | 0.00 | -0.00 | 0.00 | -185.61 | 0.00 |
STORAGE_FLR_1 | 06-JAN-23:00 | 0.00 | 0.00 | 0.00 | -657.48 | 0.00 | 0.00 | 0.00 | 180.44 | 178.43 | 0.00 | 0.00 | 0.00 | 424.59 | 0.00 | -0.00 | 0.00 | -125.98 | 0.00 |
CORRIDOR_FLR_3 | 16-OCT-13:50 | 0.00 | 0.00 | 0.00 | -7439.76 | 0.00 | 0.00 | 0.00 | 2489.76 | 0.00 | 6304.01 | 0.00 | 333.05 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -1687.06 |
CORRIDOR_FLR_6 | 16-OCT-13:20 | 0.00 | 0.00 | 0.00 | -4056.83 | 0.00 | 0.00 | 0.00 | 658.76 | 0.00 | 3398.23 | 0.00 | 138.37 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -138.52 |
Total Facility | 16-OCT-15:02 | 0.00 | -143162.29 | 0.00 | -172362.01 | 0.00 | 0.00 | 52142.63 | 14483.93 | 77329.74 | 80578.61 | 0.00 | 5188.21 | 85801.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BASEMENT | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
RETAIL_1_FLR_1 | 30-MAR-07:03 | 0.00 | 0.00 | 251.19 | -0.00 | 0.00 | 0.00 | 358.31 | 327.48 | 360.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -407.63 | 0.00 | -329.53 | -560.66 |
RETAIL_2_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LAUNDRY_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CAFE_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
LOBBY_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_1_FLR_3 | 25-FEB-16:02 | 3844.81 | 369.68 | 0.00 | -369.68 | 0.00 | 0.00 | 156.25 | 35.53 | 305.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -776.67 | 0.00 | -261.23 | -3304.23 |
ROOM_2_FLR_3 | 15-DEC-09:02 | 3876.73 | 368.13 | 0.00 | -368.13 | 0.00 | 0.00 | 103.51 | 248.71 | 452.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -334.99 | 0.00 | -229.31 | -4117.64 |
ROOM_3_MULT19_FLR_3 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 18-FEB-16:03 | 20742.34 | 5786.43 | 0.00 | -5786.43 | 0.00 | 0.00 | 2754.70 | 424.43 | 5687.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -84.85 | 0.00 | -10862.12 | -18662.17 |
ROOM_5_FLR_3 | 25-FEB-16:02 | 3691.31 | 368.87 | 0.00 | -368.87 | 0.00 | 0.00 | 156.22 | 35.53 | 305.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -776.97 | 0.00 | -260.93 | -3150.70 |
ROOM_6_FLR_3 | 25-FEB-16:02 | 3702.78 | 359.11 | 0.00 | -359.11 | 0.00 | 0.00 | 157.12 | 35.53 | 305.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -752.80 | 0.00 | -257.28 | -3190.86 |
ROOM_1_FLR_6 | 25-FEB-16:02 | 1148.24 | 85.97 | 0.00 | -85.97 | 0.00 | 0.00 | 39.78 | 8.88 | 76.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -187.50 | 0.00 | -63.33 | -1022.46 |
ROOM_2_FLR_6 | 03-JAN-09:02 | 1160.13 | 78.41 | 0.00 | -78.41 | 0.00 | 0.00 | 26.83 | 62.18 | 113.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -90.65 | 0.00 | -59.97 | -1211.77 |
ROOM_3_MULT9_FLR_6 | 30-MAR-08:62 | 5104.42 | 741.43 | 0.00 | -741.43 | 0.00 | 0.00 | 235.43 | 351.83 | 998.70 | 620.60 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -352.73 | -6958.24 |
BANQUET_FLR_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
DINING_FLR_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
KITCHEN_FLR_6 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MECH_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
STORAGE_FLR_1 | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 30-MAR-08:62 | 0.00 | 0.00 | 901.47 | -0.00 | 0.00 | 0.00 | 0.00 | 3983.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -31.86 | 0.00 | -393.19 | -4460.03 |
CORRIDOR_FLR_6 | 07-MAR-05:50 | 0.00 | 0.00 | 518.77 | -0.00 | 0.00 | 0.00 | 0.00 | 527.01 | 0.00 | 0.00 | 0.00 | 0.00 | 171.84 | 0.00 | -995.89 | 0.00 | -221.72 | 0.00 |
Total Facility | 29-MAR-08:62 | -77382.76 | 127812.34 | 4.85 | -127812.34 | 0.00 | 0.00 | 21816.32 | 28417.92 | 88432.23 | 40.16 | 0.00 | 0.00 | 0.00 | 0.00 | -10040.60 | 0.00 | -10365.79 | -40922.34 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV WITH REHEAT | 20.5098 | 0.0000 | 0.0000 | 1.0000 | 0.0000 | 20.0633 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | ||
FLR_3_DOAS | 2.0508 | 0.0000 | 0.0000 | 1.0000 | 0.0000 | 2.0512 | 0.0000 | 1.0000 | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
VAV WITH REHEAT | 12.0598 | 0.0000 | 0.0000 | 1.0000 | 0.0000 | 12.0598 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | ||
FLR_3_DOAS | 2.0508 | 0.0000 | 0.0000 | 1.0000 | 0.0000 | 2.0508 | 0.0000 | 1.0000 | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BASEMENT | VAV WITH REHEAT | 0.000000 | 106.4990 | 0.000432 | 1978.83 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | 0.000000 | 10.8290 | 0.001181 | 67.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | 0.000000 | 12.5400 | 0.001181 | 77.67 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | 0.000000 | 8.4000 | 0.003024 | 78.04 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | 0.000000 | 142.3000 | 0.003580 | 188.86 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | 0.000000 | 422.4350 | 0.001447 | 1308.19 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000395 | 156.09 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000395 | 156.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 0.000000 | 114.0000 | 0.000449 | 1863.81 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.000000 | 114.0000 | 0.000449 | 1864.32 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000395 | 156.09 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.000000 | 6.0000 | 0.000395 | 156.07 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.000000 | 1.5000 | 0.000395 | 39.02 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.000000 | 1.5000 | 0.000395 | 39.02 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.000000 | 13.5000 | 0.000449 | 220.77 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
BANQUET_FLR_6 | VAV WITH REHEAT | 0.000000 | 249.8960 | 0.003580 | 331.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
DINING_FLR_6 | VAV WITH REHEAT | 0.000000 | 249.8960 | 0.003580 | 331.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | 0.000000 | 22.2380 | 0.003555 | 103.30 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
MECH_FLR_1 | VAV WITH REHEAT | 0.000000 | 0.0000 | 0.000000 | 164.24 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | 0.000000 | 0.0000 | 0.000609 | 94.76 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | 0.000000 | 0.0000 | 0.000305 | 1557.62 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | 0.000000 | 0.0000 | 0.000305 | 412.12 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
VAV WITH REHEAT | 0.00 | 0.001080 | 6694.0231 | 0.0000 | 0.0000 | 0.0000 | |
FLR_3_DOAS | 0.00 | 0.000441 | 4651.2638 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.3619 | 2.3619 | 1.3888 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2931 | 0.2931 | 0.1724 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2302 | 0.2302 | 0.1354 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.3121 | 3.3121 | 1.9475 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2767 | 1.2767 | 0.7507 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 4.4972 | 4.4972 | 2.6444 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 0.8370 | 0.8370 | 0.8370 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.8370 | 0.8370 | 0.8370 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.0154 | 0.0154 | 0.0154 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.0154 | 0.0154 | 0.0154 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.0991 | 0.0991 | 0.0991 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
BANQUET_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.0843 | 2.0843 | 1.2256 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DINING_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.1891 | 2.1891 | 1.2872 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.2213 | 2.2213 | 1.3061 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
MECH_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2113 | 0.2113 | 0.1242 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0978 | 0.0978 | 0.0575 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1869 | 1.1869 | 0.6979 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5477 | 0.5477 | 0.3221 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV WITH REHEAT | 20.5098 | 20.0633 | 20.5098 | 12.0598 | 0.0000 | 1.0000 |
FLR_3_DOAS | 2.0508 | 2.0512 | 2.0508 | 2.0508 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BASEMENT | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3888 | 1.3888 | 1.3888 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_1_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1724 | 0.1724 | 0.1724 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
RETAIL_2_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1354 | 0.1354 | 0.1354 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LAUNDRY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.9475 | 1.9475 | 1.9475 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CAFE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7507 | 0.7507 | 0.7507 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
LOBBY_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.6444 | 2.6444 | 2.6444 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
ROOM_1_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_2_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_3_MULT19_FLR_3 | FLR_3_DOAS | 0.8370 | 0.8370 | 0.8370 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_4_MULT19_FLR_3 | FLR_3_DOAS | 0.8370 | 0.8370 | 0.8370 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_5_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_6_FLR_3 | FLR_3_DOAS | 0.0617 | 0.0617 | 0.0617 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_1_FLR_6 | FLR_3_DOAS | 0.0154 | 0.0154 | 0.0154 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_2_FLR_6 | FLR_3_DOAS | 0.0154 | 0.0154 | 0.0154 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ROOM_3_MULT9_FLR_6 | FLR_3_DOAS | 0.0991 | 0.0991 | 0.0991 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
BANQUET_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2256 | 1.2256 | 1.2256 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
DINING_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2872 | 1.2872 | 1.2872 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
KITCHEN_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3061 | 1.3061 | 1.3061 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
MECH_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1242 | 0.1242 | 0.1242 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
STORAGE_FLR_1 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0575 | 0.0575 | 0.0575 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_3 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6979 | 0.6979 | 0.6979 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORRIDOR_FLR_6 | VAV WITH REHEAT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3221 | 0.3221 | 0.3221 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
VAV WITH REHEAT | 12.0598 | 12.0598 | 12.0598 | 12.0598 | 0.0000 | 1.0000 |
FLR_3_DOAS | 2.0508 | 2.0508 | 2.0508 | 2.0508 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:47:16
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Total gross floor area [m2] | 11345.29 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BASEMENT | 1978.83 | 1978.83 | 0.00 | 168.00 |
RETAIL_1_FLR_1 | 67.07 | 67.07 | 0.00 | 168.00 |
RETAIL_2_FLR_1 | 77.67 | 77.67 | 0.00 | 168.00 |
LAUNDRY_FLR_1 | 78.04 | 78.04 | 0.00 | 168.00 |
CAFE_FLR_1 | 188.86 | 188.86 | 0.00 | 168.00 |
LOBBY_FLR_1 | 1308.19 | 1308.19 | 0.00 | 168.00 |
ROOM_1_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_2_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_3_MULT19_FLR_3 | 24.52 | 24.52 | 0.00 | 0.00 |
ROOM_4_MULT19_FLR_3 | 24.53 | 24.53 | 0.00 | 168.00 |
ROOM_5_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_6_FLR_3 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_1_FLR_6 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_2_FLR_6 | 39.02 | 39.02 | 0.00 | 168.00 |
ROOM_3_MULT9_FLR_6 | 24.53 | 24.53 | 0.00 | 168.00 |
BANQUET_FLR_6 | 331.66 | 331.66 | 0.00 | 168.00 |
DINING_FLR_6 | 331.66 | 331.66 | 0.00 | 168.00 |
KITCHEN_FLR_6 | 103.30 | 103.30 | 0.00 | 168.00 |
MECH_FLR_1 | 164.24 | 164.24 | 0.00 | 0.00 |
STORAGE_FLR_1 | 94.76 | 94.76 | 0.00 | 0.00 |
CORRIDOR_FLR_3 | 389.40 | 389.40 | 0.00 | 0.00 |
CORRIDOR_FLR_6 | 412.12 | 412.12 | 0.00 | 0.00 |
Totals | 11345.29 | 11345.29 | 0.00 |
Data | |
Number of hours heating loads not met | 3.67 |
Number of hours cooling loads not met | 78.83 |
Number of hours not met | 82.50 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Boiler | 0.00 | 0.00 | 963.34 | 214982.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 1005.13 | 182724.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 767.80 | 66976.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 226.76 | 14423.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 959.57 | 59492.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- Cooking | 762.04 | 29240.64 | 1198.64 | 74976.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ReachInFreezer | 14.43 | 457.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ReachInRefrigerator | 8.99 | 285.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- Laundry | 0.00 | 0.00 | 590.21 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 32.47 | 1873.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLift | 947.54 | 61110.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- ElevatorLightsFan | 2.91 | 187.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 560.82 | 26465.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 130.74 | 6680.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 90.76 | 4739.51 | 2038.30 | 175037.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- General | 7.09 | 2093.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- LowTempRefrigeration | 20.34 | 1913.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- MedTempRefrigeration | 34.53 | 1196.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 1806.99 | 5571.92 |
Natural Gas | 1788.85 | 4790.50 |
Additional | 0.00 | 0.00 |
Total | 3595.84 | 10362.42 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 67.68 |
Space Heating | 0.00 |
Space Cooling | 88.59 |
Fans (All) | 49.43 |
Service Water Heating | 8.00 |
Receptacle Equipment | 153.81 |
Miscellaneous (All) | 491.12 |
Subtotal | 491.12 |
Natural Gas [MJ/m2] | |
Space Heating | 84.91 |
Service Water Heating | 179.66 |
Miscellaneous (All) | 422.25 |
Subtotal | 422.25 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 7.41 |
Space Heating | 9.30 |
Space Cooling | 9.70 |
Fans (All) | 5.41 |
Service Water Heating | 20.55 |
Receptacle Equipment | 34.10 |
Miscellaneous | 13.53 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
BLDG_LIGHT_CORRIDOR_SCH | 3061. | 8760. |
BLDG_LIGHT_GUESTROOM_SCH | 2221. | 8760. |
BLDG_LIGHT_MECHANIC_SCH | 3061. | 8760. |
BLDG_LIGHT_MISC_SCH | 3061. | 8760. |
BLDG_LIGHT_OFFICE_BSMT_SCH | 2842. | 8760. |
BLDG_LIGHT_SCH | 3061. | 8760. |
BLDG_LIGHT_STORAGE_SCH | 1591. | 8760. |
WALKIN_OCC_LGHT_SCH | 1591. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
BASEMENT_EQUIP_SCH | 3924. | 8760. |
BLDG_EQUIP_SCH | 3924. | 8760. |
GUESTROOM_EQP_SCH_BASE | 3239. | 8760. |
GUESTROOM_EQP_SCH_ADVA | 2762. | 8760. |
LOBBY_EQP_SCH | 3292. | 8760. |
OFFICE_EQP_SCH | 4941. | 8760. |
EMPLOYEELOUNGE_EQP_SCH | 4044. | 8760. |
LAUNDRYROOM_EQP_ELEC_SCH | 2920. | 2920. |
LAUNDRYROOM_EQP_GAS_SCH | 2920. | 2920. |
MEETINGROOM_EQP_SCH | 1336. | 4745. |
EXERCISEROOM_EQP_SCH | 3832. | 5840. |
KITCHEN_ELEC_EQUIP_SCH | 2172. | 8760. |
KITCHEN_GAS_EQUIP_SCH | 1332. | 8760. |
KITCHEN_EXHAUST_SCH | 6205. | 6205. |
BLDG_ELEVATORS | 2154. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 2154. | 8760. |
BLDG_OCC_SCH | 5026. | 8760. |
GUESTROOM_OCC_SCH | 5515. | 8760. |
LOBBY_OCC_SCH | 2304. | 8760. |
OFFICE_OCC_SCH | 3954. | 8760. |
EMPLOYEELOUNGE_OCC_SCH | 948. | 5475. |
MEETINGROOM_OCC_SCH | 1168. | 4745. |
LAUNDRYROOM_OCC_SCH | 427. | 2920. |
EXERCISEROOM_OCC_SCH | 5292. | 5840. |
INFIL_SCH | 8760. | 8760. |
INFIL_HALF_ON_SCH | 4380. | 8760. |
INFIL_QUARTER_ON_SCH | 2190. | 8760. |
LAUNDRY_SWH_SCH | 2555. | 2555. |
BLDG_SWH_SCH | 3301. | 8760. |
GUESTROOM_SWH_SCH | 2899. | 8760. |
LAUNDRYROOM_SWH_SCH | 2920. | 2920. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
ALWAYS_ON | 8760. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
OCC_GUESTROOM_VENT_CTRL_30MIN | 6570. | 6570. |
OCC_GUESTROOM_VENT_CTRL_20MIN | 6327. | 6327. |
VAC_GUESTROOM_VENTILATION_SCHEDULE | 365. | 365. |
MINOA_MOTORIZEDDAMPER_SCHED | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
ROOM_1_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_1_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_2_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_2_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_3_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_4_MULT19_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_5_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_5_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_6_FLR_3 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_6_FLR_3 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_1_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_1_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_2_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_2_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
ROOM_3_MULT9_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
KITCHEN_FLR_6 WATER EQUIPMENT LATENT FRACT SCHED | 438. | 8760. |
KITCHEN_FLR_6 WATER EQUIPMENT SENSIBLE FRACT SCHED | 1752. | 8760. |
KITCHEN_FLR_6_CASE:1_WALKINFREEZER_CASECREDITREDUXSCHED | 2774. | 8760. |
FLR_3_DOAS_OAMINOAFRACSCHEDULE | 8760. | 8760. |
LAUNDRY_FLR_1 EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE | 0. | 0. |
KITCHEN EXHAUST FAN BALANCED EXHAUST FRACTION SCHEDULE | 5740. | 6205. |
SLIDING_DOORS_VENTILATION_AVAILABILITY_SCH | 3285. | 3285. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
OBCRESET_S_OCCGUESTROOM_HTGSP_SCH_30MIN | S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
OBCRESET_S_OCCGUESTROOM_CLGSP_SCH_30MIN | S OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 21.11 | 365 |
OBCRESET_N_OCCGUESTROOM_HTGSP_SCH_30MIN | N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 21.11 | 365 | 21.11 | 365 |
OBCRESET_N_OCCGUESTROOM_CLGSP_SCH_30MIN | N OCCGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 21.11 | 365 |
VACGUESTROOM_HTGSP_SCH | VACGUESTROOM THERMOSTAT DUAL SP CONTROL | January | 18.89 | 365 | 18.89 | 365 |
VACGUESTROOM_CLGSP_SCH | VACGUESTROOM THERMOSTAT DUAL SP CONTROL | July | 23.33 | 365 | 23.33 | 365 |
HTGSETP_SCH | BASEMENT DUALSPSCHED | January | 21.00 | 365 | 21.00 | 365 |
CLGSETP_SCH | BASEMENT DUALSPSCHED | July | 24.00 | 365 | 24.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME HOTELLARGE
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3C
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CA_SANDIEGO
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.156792E+12 |
February | 0.000 | 0.126434E+12 |
March | 0.000 | 0.169965E+12 |
April | 0.000 | 0.779624E+11 |
May | 0.000 | 0.715442E+11 |
June | 0.000 | 0.230500E+11 |
July | 0.000 | 0.144873E+11 |
August | 0.000 | 0.131432E+11 |
September | 0.000 | 0.164010E+11 |
October | 0.000 | 0.340714E+11 |
November | 0.000 | 0.106289E+12 |
December | 0.000 | 0.153200E+12 |
Annual Sum or Average | 0.963340E+12 | |
Minimum of Months | 0.000 | 0.131432E+11 |
Maximum of Months | 0.000 | 0.169965E+12 |
Report: ZoneCoolingSummaryMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.375945E+11 | 22827.97 | 08-JAN-07:00 | 1.00 | -0.2 | 0.721244E+10 | 4666.55 | 31-JAN-22:10 | 11.82 | 10.56 |
February | 0.307732E+11 | 17462.34 | 04-FEB-05:55 | 5.00 | 0.20 | 0.630580E+10 | 4537.84 | 01-FEB-22:10 | 13.00 | 11.77 |
March | 0.336668E+11 | 18234.99 | 08-MAR-02:00 | 4.00 | 3.53 | 0.683127E+10 | 4368.85 | 06-MAR-22:10 | 10.17 | 8.07 |
April | 0.324484E+11 | 14646.70 | 26-APR-07:50 | 21.33 | 16.21 | 0.649482E+10 | 4250.76 | 06-APR-21:10 | 12.17 | 11.07 |
May | 0.335964E+11 | 14489.83 | 28-MAY-10:00 | 21.00 | 15.41 | 0.666101E+10 | 4264.08 | 12-MAY-21:10 | 11.83 | 11.29 |
June | 0.327108E+11 | 14562.86 | 29-JUN-18:20 | 21.00 | 18.13 | 0.628451E+10 | 4123.29 | 01-JUN-21:10 | 13.83 | 13.26 |
July | 0.362944E+11 | 15169.10 | 19-JUL-18:50 | 21.33 | 18.46 | 0.651647E+10 | 4139.92 | 07-JUL-21:10 | 15.17 | 13.85 |
August | 0.367574E+11 | 15073.25 | 14-AUG-18:50 | 21.17 | 18.40 | 0.657784E+10 | 4158.68 | 25-AUG-21:10 | 16.08 | 16.08 |
September | 0.365308E+11 | 16591.48 | 21-SEP-21:10 | 21.17 | 19.64 | 0.665094E+10 | 4396.73 | 19-SEP-21:10 | 13.83 | 12.17 |
October | 0.388850E+11 | 16451.91 | 16-OCT-19:50 | 21.33 | 13.33 | 0.706413E+10 | 4560.50 | 27-OCT-21:10 | 13.00 | 10.71 |
November | 0.366562E+11 | 17073.40 | 29-NOV-23:00 | 7.00 | 4.65 | 0.723379E+10 | 4765.65 | 17-NOV-22:10 | 11.00 | 9.96 |
December | 0.374477E+11 | 18766.97 | 03-DEC-01:00 | 5.00 | 5.00 | 0.727767E+10 | 4727.10 | 01-DEC-22:10 | 10.83 | 10.40 |
Annual Sum or Average | 0.423361E+12 | 0.811107E+11 | ||||||||
Minimum of Months | 0.307732E+11 | 14489.83 | 1.00 | -0.2 | 0.628451E+10 | 4123.29 | 10.17 | 8.07 | ||
Maximum of Months | 0.388850E+11 | 22827.97 | 21.33 | 19.64 | 0.727767E+10 | 4765.65 | 16.08 | 16.08 |
Report: ZoneCoolingSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.352546E+10 | 3069.65 | 14-JAN-12:40 | 25.33 | 11.67 | 0.650304E+09 | 414.76 | 20-JAN-22:10 | 13.17 | 13.17 |
February | 0.285673E+10 | 2492.49 | 02-FEB-12:40 | 19.33 | 12.34 | 0.582244E+09 | 418.72 | 01-FEB-22:10 | 13.00 | 11.77 |
March | 0.275234E+10 | 2250.90 | 11-MAR-13:10 | 24.00 | 13.62 | 0.634347E+09 | 408.03 | 24-MAR-21:10 | 13.00 | 11.77 |
April | 0.321739E+10 | 1992.78 | 08-APR-12:50 | 22.17 | 16.55 | 0.611147E+09 | 397.57 | 27-APR-21:10 | 14.00 | 12.83 |
May | 0.305951E+10 | 1840.72 | 04-MAY-12:40 | 23.33 | 16.62 | 0.625262E+09 | 398.15 | 03-MAY-21:10 | 16.00 | 14.66 |
June | 0.342932E+10 | 1808.96 | 29-JUN-18:10 | 21.50 | 18.38 | 0.608269E+09 | 393.27 | 28-JUN-21:10 | 17.00 | 16.37 |
July | 0.401807E+10 | 1874.49 | 19-JUL-18:10 | 22.67 | 18.89 | 0.630714E+09 | 400.45 | 19-JUL-21:10 | 18.00 | 17.89 |
August | 0.423276E+10 | 1951.74 | 27-AUG-12:00 | 23.00 | 18.42 | 0.641210E+09 | 405.47 | 18-AUG-21:10 | 19.00 | 17.66 |
September | 0.404125E+10 | 2906.15 | 30-SEP-13:10 | 32.00 | 16.95 | 0.627673E+09 | 454.50 | 29-SEP-21:10 | 24.58 | 13.49 |
October | 0.446814E+10 | 3685.50 | 16-OCT-12:10 | 35.68 | 17.44 | 0.667394E+09 | 457.81 | 16-OCT-21:10 | 18.33 | 11.04 |
November | 0.371389E+10 | 3369.40 | 19-NOV-12:30 | 26.50 | 15.20 | 0.635575E+09 | 421.91 | 20-NOV-22:10 | 14.00 | 12.83 |
December | 0.376236E+10 | 3163.85 | 19-DEC-12:50 | 25.83 | 11.50 | 0.658287E+09 | 423.71 | 05-DEC-22:10 | 17.17 | 9.43 |
Annual Sum or Average | 0.430772E+11 | 0.757243E+10 | ||||||||
Minimum of Months | 0.275234E+10 | 1808.96 | 19.33 | 11.50 | 0.582244E+09 | 393.27 | 13.00 | 9.43 | ||
Maximum of Months | 0.446814E+10 | 3685.50 | 35.68 | 18.89 | 0.667394E+09 | 457.81 | 24.58 | 17.89 |
Report: ZoneCoolingSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.338972E+10 | 1815.08 | 06-JAN-23:00 | 5.00 | 2.02 | 0.805376E+09 | 540.43 | 06-JAN-22:10 | 9.17 | 4.09 |
February | 0.295598E+10 | 1666.66 | 04-FEB-05:55 | 5.00 | 0.20 | 0.740938E+09 | 553.92 | 02-FEB-22:10 | 11.00 | 8.45 |
March | 0.323216E+10 | 1685.44 | 08-MAR-01:50 | 4.17 | 3.62 | 0.806904E+09 | 543.73 | 24-MAR-21:10 | 13.00 | 11.77 |
April | 0.328178E+10 | 1509.33 | 26-APR-20:20 | 16.67 | 15.19 | 0.795323E+09 | 538.10 | 28-APR-21:10 | 14.00 | 11.20 |
May | 0.339163E+10 | 1528.09 | 04-MAY-21:10 | 17.00 | 15.07 | 0.815118E+09 | 533.57 | 19-MAY-21:10 | 12.17 | 11.62 |
June | 0.347194E+10 | 1553.98 | 29-JUN-18:20 | 21.00 | 18.13 | 0.788594E+09 | 530.92 | 30-JUN-21:10 | 16.02 | 14.99 |
July | 0.375588E+10 | 1612.40 | 19-JUL-19:00 | 21.00 | 18.35 | 0.812852E+09 | 529.37 | 26-JUL-21:10 | 17.00 | 16.26 |
August | 0.379229E+10 | 1623.02 | 18-AUG-21:10 | 19.00 | 17.66 | 0.820700E+09 | 532.26 | 25-AUG-21:10 | 16.08 | 16.08 |
September | 0.358833E+10 | 1756.10 | 29-SEP-21:10 | 24.58 | 13.49 | 0.795502E+09 | 548.07 | 29-SEP-21:10 | 24.58 | 13.49 |
October | 0.374747E+10 | 1754.71 | 16-OCT-19:50 | 21.33 | 13.33 | 0.830120E+09 | 561.39 | 17-OCT-21:10 | 18.00 | 14.86 |
November | 0.332029E+10 | 1641.38 | 29-NOV-23:00 | 7.00 | 4.65 | 0.807336E+09 | 553.86 | 22-NOV-22:10 | 11.17 | 2.65 |
December | 0.343600E+10 | 1674.52 | 03-DEC-01:00 | 5.00 | 5.00 | 0.818923E+09 | 545.62 | 29-DEC-22:10 | 11.67 | 7.63 |
Annual Sum or Average | 0.413635E+11 | 0.963769E+10 | ||||||||
Minimum of Months | 0.295598E+10 | 1509.33 | 4.17 | 0.20 | 0.740938E+09 | 529.37 | 9.17 | 2.65 | ||
Maximum of Months | 0.379229E+10 | 1815.08 | 24.58 | 18.35 | 0.830120E+09 | 561.39 | 24.58 | 16.26 |
Report: ZoneCoolingSummaryMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.255792E+10 | 1482.17 | 06-JAN-23:00 | 5.00 | 2.02 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.234711E+10 | 1273.64 | 06-FEB-23:00 | 7.00 | 3.15 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.246117E+10 | 1340.05 | 07-MAR-23:00 | 6.00 | 5.04 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.267591E+10 | 1277.36 | 26-APR-07:50 | 21.33 | 16.21 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.284928E+10 | 1271.25 | 04-MAY-09:30 | 21.00 | 15.48 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.300325E+10 | 1335.30 | 29-JUN-18:10 | 21.50 | 18.38 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.327522E+10 | 1386.32 | 19-JUL-19:00 | 21.00 | 18.35 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.327284E+10 | 1365.06 | 19-AUG-18:50 | 21.33 | 18.21 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.304323E+10 | 1455.90 | 29-SEP-21:00 | 24.60 | 13.47 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.319284E+10 | 1476.33 | 16-OCT-19:50 | 21.33 | 13.33 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.270798E+10 | 1329.46 | 29-NOV-23:00 | 7.00 | 4.65 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.268782E+10 | 1435.79 | 03-DEC-01:00 | 5.00 | 5.00 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.340746E+11 | 0.00 | ||||||||
Minimum of Months | 0.234711E+10 | 1271.25 | 5.00 | 2.02 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.327522E+10 | 1482.17 | 24.60 | 18.38 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.106652E+10 | 657.52 | 06-JAN-23:00 | 5.00 | 2.02 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.100395E+10 | 581.33 | 03-FEB-10:05 | 21.17 | 8.32 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.100721E+10 | 570.49 | 23-MAR-09:50 | 21.50 | 16.14 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.118424E+10 | 580.93 | 26-APR-07:50 | 21.33 | 16.21 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.126592E+10 | 585.73 | 04-MAY-09:40 | 21.33 | 15.79 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.135831E+10 | 603.18 | 30-JUN-08:40 | 21.33 | 17.66 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.149050E+10 | 618.13 | 19-JUL-18:50 | 21.33 | 18.46 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.149033E+10 | 611.80 | 19-AUG-18:50 | 21.33 | 18.21 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.138244E+10 | 649.21 | 29-SEP-21:10 | 24.58 | 13.49 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.145325E+10 | 656.35 | 16-OCT-19:50 | 21.33 | 13.33 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.121082E+10 | 597.82 | 19-NOV-13:10 | 26.67 | 14.98 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.116002E+10 | 604.30 | 03-DEC-00:25 | 6.00 | 6.00 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.150735E+11 | 0.00 | ||||||||
Minimum of Months | 0.100395E+10 | 570.49 | 5.00 | 2.02 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.149050E+10 | 657.52 | 26.67 | 18.46 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.513424E+11 | 37266.84 | 24-JAN-21:00 | 17.00 | 11.90 | 0.543103E+09 | 396.75 | 04-JAN-22:10 | 10.33 | 6.24 |
February | 0.462389E+11 | 37081.08 | 17-FEB-21:00 | 14.00 | 13.42 | 0.499126E+09 | 396.50 | 09-FEB-22:10 | 10.08 | 10.08 |
March | 0.512858E+11 | 37422.73 | 23-MAR-20:00 | 14.00 | 13.42 | 0.550295E+09 | 393.10 | 06-MAR-22:10 | 10.17 | 8.07 |
April | 0.501848E+11 | 37579.03 | 26-APR-20:00 | 17.00 | 15.07 | 0.533847E+09 | 384.25 | 06-APR-21:10 | 12.17 | 11.07 |
May | 0.519723E+11 | 37581.90 | 04-MAY-20:00 | 17.00 | 15.07 | 0.550535E+09 | 391.78 | 10-MAY-21:10 | 11.00 | 9.40 |
June | 0.508790E+11 | 37560.55 | 30-JUN-20:00 | 16.00 | 15.39 | 0.526748E+09 | 382.91 | 12-JUN-21:10 | 12.33 | 11.13 |
July | 0.529051E+11 | 37764.96 | 19-JUL-20:00 | 19.00 | 18.34 | 0.537933E+09 | 381.52 | 11-JUL-21:00 | 16.00 | 14.12 |
August | 0.531585E+11 | 37712.24 | 18-AUG-20:00 | 19.00 | 17.66 | 0.540424E+09 | 381.52 | 22-AUG-21:30 | 16.15 | 14.32 |
September | 0.508028E+11 | 38066.93 | 29-SEP-20:00 | 25.00 | 13.56 | 0.523590E+09 | 381.55 | 14-SEP-21:10 | 16.00 | 14.12 |
October | 0.526123E+11 | 37973.14 | 16-OCT-20:00 | 21.00 | 13.05 | 0.541948E+09 | 383.69 | 11-OCT-21:10 | 12.17 | 9.11 |
November | 0.500239E+11 | 37230.25 | 20-NOV-21:00 | 14.00 | 13.42 | 0.533923E+09 | 394.43 | 22-NOV-22:10 | 11.17 | 2.65 |
December | 0.513443E+11 | 37354.96 | 05-DEC-21:00 | 16.00 | 9.07 | 0.547271E+09 | 395.35 | 22-DEC-22:10 | 10.25 | 9.80 |
Annual Sum or Average | 0.612750E+12 | 0.642874E+10 | ||||||||
Minimum of Months | 0.462389E+11 | 37081.08 | 14.00 | 9.07 | 0.499126E+09 | 381.52 | 10.08 | 2.65 | ||
Maximum of Months | 0.531585E+11 | 38066.93 | 25.00 | 18.34 | 0.550535E+09 | 396.75 | 16.15 | 14.32 |
Report: ZoneCoolingSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.202924E+11 | 12187.34 | 14-JAN-12:40 | 25.33 | 11.67 | 0.959893E+10 | 6393.92 | 20-JAN-22:40 | 13.67 | 13.67 |
February | 0.170777E+11 | 9920.14 | 04-FEB-12:30 | 21.00 | 8.23 | 0.870370E+10 | 6442.35 | 03-FEB-22:40 | 11.00 | 4.20 |
March | 0.181106E+11 | 9765.34 | 11-MAR-13:10 | 24.00 | 13.62 | 0.934945E+10 | 6274.89 | 24-MAR-21:40 | 13.00 | 11.48 |
April | 0.183346E+11 | 8801.49 | 08-APR-12:30 | 22.50 | 16.83 | 0.916582E+10 | 6137.46 | 04-APR-22:10 | 12.00 | 11.91 |
May | 0.182822E+11 | 8668.57 | 04-MAY-21:30 | 17.00 | 15.07 | 0.932032E+10 | 6077.77 | 04-MAY-21:40 | 17.00 | 15.07 |
June | 0.188293E+11 | 8569.54 | 27-JUN-22:00 | 17.00 | 16.37 | 0.906369E+10 | 6015.05 | 30-JUN-22:10 | 16.13 | 16.03 |
July | 0.206601E+11 | 8962.37 | 31-JUL-21:30 | 18.85 | 17.85 | 0.934612E+10 | 6045.21 | 19-JUL-22:10 | 18.00 | 17.35 |
August | 0.213086E+11 | 9088.45 | 18-AUG-21:30 | 19.00 | 17.66 | 0.952060E+10 | 6105.96 | 25-AUG-22:10 | 16.00 | 16.00 |
September | 0.205547E+11 | 10902.73 | 30-SEP-12:00 | 32.00 | 17.08 | 0.933163E+10 | 6459.91 | 29-SEP-21:49 | 24.52 | 13.57 |
October | 0.221338E+11 | 12873.35 | 15-OCT-12:00 | 32.00 | 16.86 | 0.988735E+10 | 6460.34 | 18-OCT-22:10 | 13.83 | 13.83 |
November | 0.197956E+11 | 13362.05 | 19-NOV-11:00 | 26.00 | 15.05 | 0.957578E+10 | 6442.21 | 30-NOV-22:40 | 11.27 | 5.50 |
December | 0.207345E+11 | 12113.54 | 16-DEC-13:00 | 26.00 | 13.28 | 0.977602E+10 | 6447.05 | 29-DEC-22:00 | 10.00 | 5.88 |
Annual Sum or Average | 0.236114E+12 | 0.112639E+12 | ||||||||
Minimum of Months | 0.170777E+11 | 8569.54 | 17.00 | 8.23 | 0.870370E+10 | 6015.05 | 10.00 | 4.20 | ||
Maximum of Months | 0.221338E+11 | 13362.05 | 32.00 | 17.85 | 0.988735E+10 | 6460.34 | 24.52 | 17.35 |
Report: ZoneCoolingSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.708173E+11 | 37274.65 | 03-JAN-01:55 | 3.00 | 2.55 | 0.286461E+11 | 19030.14 | 05-JAN-22:40 | 9.67 | 7.31 |
February | 0.614486E+11 | 34483.98 | 04-FEB-05:55 | 5.00 | 0.20 | 0.263268E+11 | 19183.23 | 02-FEB-23:10 | 11.17 | 8.77 |
March | 0.671333E+11 | 34765.60 | 08-MAR-02:00 | 4.00 | 3.53 | 0.285794E+11 | 18945.63 | 24-MAR-22:10 | 13.00 | 11.28 |
April | 0.669577E+11 | 30327.50 | 26-APR-22:00 | 16.00 | 15.39 | 0.279566E+11 | 18759.43 | 06-APR-21:40 | 12.67 | 11.55 |
May | 0.689864E+11 | 31132.23 | 04-MAY-21:10 | 17.00 | 15.07 | 0.286572E+11 | 18675.81 | 26-MAY-22:10 | 11.00 | 8.45 |
June | 0.702757E+11 | 30973.80 | 28-JUN-21:10 | 17.00 | 16.37 | 0.276549E+11 | 18421.18 | 02-JUN-22:10 | 14.00 | 12.83 |
July | 0.754866E+11 | 32239.98 | 31-JUL-21:10 | 18.95 | 17.72 | 0.283482E+11 | 18323.93 | 20-JUL-22:10 | 17.00 | 16.37 |
August | 0.763332E+11 | 32530.01 | 18-AUG-22:00 | 19.00 | 17.66 | 0.286379E+11 | 18463.66 | 25-AUG-22:10 | 16.00 | 16.00 |
September | 0.728129E+11 | 35069.11 | 29-SEP-21:10 | 24.58 | 13.49 | 0.279011E+11 | 18833.32 | 29-SEP-22:10 | 24.48 | 13.58 |
October | 0.766032E+11 | 34654.90 | 16-OCT-22:00 | 20.00 | 11.07 | 0.292555E+11 | 19183.02 | 18-OCT-21:30 | 14.50 | 14.21 |
November | 0.687856E+11 | 33392.28 | 29-NOV-23:00 | 7.00 | 4.65 | 0.286553E+11 | 19183.49 | 29-NOV-22:10 | 10.33 | 6.41 |
December | 0.714375E+11 | 33680.80 | 23-DEC-04:00 | 5.00 | 3.64 | 0.291357E+11 | 19182.69 | 22-DEC-22:49 | 10.05 | 9.48 |
Annual Sum or Average | 0.847078E+12 | 0.339755E+12 | ||||||||
Minimum of Months | 0.614486E+11 | 30327.50 | 3.00 | 0.20 | 0.263268E+11 | 18323.93 | 9.67 | 6.41 | ||
Maximum of Months | 0.766032E+11 | 37274.65 | 24.58 | 17.72 | 0.292555E+11 | 19183.49 | 24.48 | 16.37 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.492473E+09 | 2647.50 | 14-JAN-16:01 | 23.00 | 12.39 | 97216840.12 | 56.69 | 18-JAN-22:49 | 16.17 | 13.10 |
February | 0.431454E+09 | 2603.64 | 03-FEB-16:01 | 20.50 | 10.02 | 87440234.57 | 56.69 | 01-FEB-22:10 | 13.00 | 11.77 |
March | 0.454624E+09 | 2652.86 | 11-MAR-16:01 | 21.33 | 12.79 | 96761393.98 | 56.69 | 24-MAR-21:19 | 13.00 | 11.67 |
April | 0.781118E+09 | 2618.48 | 01-APR-15:02 | 22.83 | 11.14 | 94361783.58 | 56.69 | 26-APR-22:00 | 16.00 | 14.76 |
May | 0.753673E+09 | 2491.39 | 24-MAY-15:02 | 20.67 | 15.31 | 97398128.35 | 56.69 | 03-MAY-23:10 | 16.00 | 14.03 |
June | 0.978288E+09 | 2492.48 | 20-JUN-15:02 | 21.83 | 15.75 | 94646799.22 | 56.69 | 19-JUN-22:00 | 17.00 | 15.07 |
July | 0.129945E+10 | 2575.92 | 19-JUL-15:02 | 26.67 | 20.19 | 98170702.27 | 56.69 | 25-JUL-23:00 | 18.00 | 17.35 |
August | 0.131319E+10 | 2599.41 | 19-AUG-15:02 | 25.83 | 18.85 | 98362860.89 | 56.69 | 13-AUG-23:10 | 18.83 | 17.61 |
September | 0.108822E+10 | 2556.85 | 11-SEP-15:02 | 22.00 | 16.75 | 94811926.23 | 56.69 | 30-SEP-01:19 | 24.20 | 13.93 |
October | 0.109805E+10 | 2794.85 | 15-OCT-15:02 | 30.83 | 15.36 | 97869606.23 | 56.69 | 14-OCT-23:10 | 21.33 | 10.17 |
November | 0.599598E+09 | 2602.86 | 19-NOV-09:02 | 24.33 | 12.75 | 94380242.90 | 56.69 | 10-NOV-22:10 | 15.00 | 13.80 |
December | 0.553282E+09 | 2657.93 | 05-DEC-16:01 | 22.67 | 12.39 | 97339875.19 | 56.69 | 18-DEC-23:10 | 16.83 | 5.67 |
Annual Sum or Average | 0.984341E+10 | 0.114876E+10 | ||||||||
Minimum of Months | 0.431454E+09 | 2491.39 | 20.50 | 10.02 | 87440234.57 | 56.69 | 13.00 | 5.67 | ||
Maximum of Months | 0.131319E+10 | 2794.85 | 30.83 | 20.19 | 98362860.89 | 56.69 | 24.20 | 17.61 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.214594E+09 | 2557.64 | 14-JAN-16:01 | 23.00 | 12.39 | 95774188.42 | 56.69 | 19-JAN-22:10 | 14.00 | 12.84 |
February | 0.231725E+09 | 2520.68 | 03-FEB-16:01 | 20.50 | 10.02 | 86583954.85 | 56.69 | 17-FEB-22:30 | 13.00 | 12.44 |
March | 0.309505E+09 | 2576.57 | 11-MAR-16:01 | 21.33 | 12.79 | 96094625.05 | 56.69 | 24-MAR-21:40 | 13.00 | 11.48 |
April | 0.666055E+09 | 2547.27 | 01-APR-15:02 | 22.83 | 11.14 | 93960068.03 | 56.69 | 11-APR-21:10 | 13.83 | 13.83 |
May | 0.732516E+09 | 2447.61 | 03-MAY-15:02 | 21.83 | 15.31 | 97322319.71 | 56.69 | 04-MAY-22:10 | 16.83 | 15.02 |
June | 0.986984E+09 | 2442.55 | 20-JUN-15:02 | 21.83 | 15.75 | 94650118.91 | 56.69 | 23-JUN-23:10 | 17.00 | 14.50 |
July | 0.129114E+10 | 2521.72 | 19-JUL-15:02 | 26.67 | 20.19 | 98142182.37 | 56.69 | 28-JUL-22:49 | 18.00 | 17.35 |
August | 0.122395E+10 | 2516.17 | 19-AUG-15:02 | 25.83 | 18.85 | 98159595.08 | 56.69 | 08-AUG-22:00 | 18.00 | 16.69 |
September | 0.901914E+09 | 2440.08 | 30-SEP-18:02 | 22.67 | 16.86 | 94328273.50 | 56.69 | 29-SEP-23:10 | 24.38 | 13.51 |
October | 0.795008E+09 | 2708.78 | 16-OCT-15:02 | 29.83 | 15.94 | 97170465.76 | 56.69 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.284826E+09 | 2433.17 | 27-NOV-16:01 | 19.67 | 7.52 | 93258863.78 | 56.69 | 10-NOV-22:10 | 15.00 | 13.80 |
December | 0.224402E+09 | 2575.56 | 05-DEC-16:01 | 22.67 | 12.39 | 95851338.91 | 56.69 | 05-DEC-22:49 | 17.83 | 9.37 |
Annual Sum or Average | 0.786262E+10 | 0.114130E+10 | ||||||||
Minimum of Months | 0.214594E+09 | 2433.17 | 19.67 | 7.52 | 86583954.85 | 56.69 | 13.00 | 9.37 | ||
Maximum of Months | 0.129114E+10 | 2708.78 | 29.83 | 20.19 | 98159595.08 | 56.69 | 24.38 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.524226E+09 | 597.75 | 14-JAN-12:40 | 25.33 | 11.67 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.383380E+09 | 537.83 | 02-FEB-12:30 | 19.50 | 11.89 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.323005E+09 | 399.63 | 11-MAR-13:10 | 24.00 | 13.62 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.286446E+09 | 273.26 | 08-APR-12:40 | 22.33 | 16.69 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.256415E+09 | 164.80 | 04-MAY-13:30 | 23.00 | 16.65 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.262558E+09 | 137.21 | 29-JUN-17:50 | 22.17 | 18.59 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.323667E+09 | 229.65 | 31-JUL-17:13 | 23.67 | 19.77 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.373966E+09 | 284.29 | 18-AUG-15:02 | 26.50 | 20.70 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.408857E+09 | 542.25 | 30-SEP-13:00 | 32.00 | 16.82 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.557953E+09 | 675.94 | 16-OCT-12:10 | 35.68 | 17.44 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.514991E+09 | 637.16 | 19-NOV-12:30 | 26.50 | 15.20 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.575589E+09 | 608.90 | 19-DEC-13:00 | 26.00 | 11.56 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.479105E+10 | 0.00 | ||||||||
Minimum of Months | 0.256415E+09 | 137.21 | 19.50 | 11.56 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.575589E+09 | 675.94 | 35.68 | 20.70 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.279389E+09 | 816.12 | 15-JAN-09:02 | 22.50 | 9.53 | 95726364.96 | 56.69 | 25-JAN-22:10 | 14.00 | 14.00 |
February | 0.277717E+09 | 741.35 | 01-FEB-09:02 | 22.33 | 11.83 | 86648934.18 | 56.69 | 23-FEB-22:10 | 13.83 | 11.13 |
March | 0.317268E+09 | 786.50 | 11-MAR-09:02 | 20.50 | 12.50 | 96093658.24 | 56.69 | 16-MAR-21:10 | 13.00 | 12.44 |
April | 0.402102E+09 | 789.73 | 01-APR-15:02 | 22.83 | 11.14 | 93196361.71 | 56.69 | 27-APR-22:10 | 14.00 | 12.83 |
May | 0.456023E+09 | 783.92 | 04-MAY-15:02 | 22.00 | 16.30 | 96471466.37 | 56.69 | 08-MAY-21:40 | 14.00 | 12.23 |
June | 0.515908E+09 | 781.97 | 30-JUN-15:02 | 22.95 | 17.84 | 93578422.86 | 56.69 | 01-JUN-21:30 | 13.50 | 12.93 |
July | 0.604130E+09 | 813.08 | 19-JUL-15:02 | 26.67 | 20.19 | 96858001.71 | 56.69 | 20-JUL-21:10 | 17.00 | 16.37 |
August | 0.578154E+09 | 805.76 | 19-AUG-15:02 | 25.83 | 18.85 | 96873759.86 | 56.69 | 31-AUG-22:10 | 16.65 | 15.39 |
September | 0.476874E+09 | 828.76 | 30-SEP-18:02 | 22.67 | 16.86 | 93308934.43 | 56.69 | 21-SEP-21:40 | 21.67 | 19.81 |
October | 0.487728E+09 | 901.72 | 15-OCT-08:62 | 29.67 | 14.34 | 96438666.22 | 56.69 | 19-OCT-21:19 | 17.00 | 14.51 |
November | 0.310874E+09 | 846.53 | 19-NOV-09:02 | 24.33 | 12.75 | 92876890.49 | 56.69 | 21-NOV-22:10 | 13.00 | 11.28 |
December | 0.279947E+09 | 819.35 | 05-DEC-09:02 | 24.33 | 11.99 | 95687039.60 | 56.69 | 08-DEC-22:10 | 14.00 | 12.83 |
Annual Sum or Average | 0.498612E+10 | 0.113376E+10 | ||||||||
Minimum of Months | 0.277717E+09 | 741.35 | 20.50 | 9.53 | 86648934.18 | 56.69 | 13.00 | 11.13 | ||
Maximum of Months | 0.604130E+09 | 901.72 | 29.67 | 20.19 | 96873759.86 | 56.69 | 21.67 | 19.81 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.519082E+09 | 2320.84 | 14-JAN-16:01 | 23.00 | 12.39 | 97481241.95 | 56.69 | 20-JAN-22:10 | 13.17 | 13.17 |
February | 0.403522E+09 | 2274.87 | 01-FEB-09:02 | 22.33 | 11.83 | 87558116.25 | 56.69 | 22-FEB-22:10 | 12.00 | 10.34 |
March | 0.445853E+09 | 2300.47 | 11-MAR-16:01 | 21.33 | 12.79 | 96957756.61 | 56.69 | 13-MAR-01:10 | 12.00 | 11.27 |
April | 0.703732E+09 | 2254.87 | 01-APR-15:02 | 22.83 | 11.14 | 94580005.75 | 56.69 | 08-APR-01:19 | 12.67 | 12.11 |
May | 0.657679E+09 | 2192.80 | 24-MAY-08:62 | 18.00 | 8.77 | 97361439.05 | 56.69 | 24-MAY-21:30 | 16.00 | 14.12 |
June | 0.829654E+09 | 2131.02 | 21-JUN-15:02 | 22.00 | 16.40 | 94600256.74 | 56.69 | 28-JUN-21:49 | 17.00 | 16.37 |
July | 0.116702E+10 | 2177.32 | 23-JUL-08:62 | 23.33 | 19.10 | 98410696.88 | 56.69 | 27-JUL-22:00 | 18.00 | 17.35 |
August | 0.122851E+10 | 2179.64 | 19-AUG-15:02 | 25.83 | 18.85 | 98643033.77 | 56.69 | 15-AUG-23:49 | 18.00 | 17.35 |
September | 0.927667E+09 | 2211.90 | 30-SEP-18:02 | 22.67 | 16.86 | 94775883.67 | 56.69 | 29-SEP-21:19 | 24.57 | 13.51 |
October | 0.103908E+10 | 2442.48 | 15-OCT-08:62 | 29.67 | 14.34 | 98015349.37 | 56.69 | 17-OCT-21:19 | 18.00 | 14.76 |
November | 0.563279E+09 | 2368.28 | 19-NOV-09:02 | 24.33 | 12.75 | 94489531.72 | 56.69 | 20-NOV-22:10 | 14.00 | 12.83 |
December | 0.555010E+09 | 2355.92 | 05-DEC-09:02 | 24.33 | 11.99 | 97544394.87 | 56.69 | 18-DEC-23:10 | 16.83 | 5.67 |
Annual Sum or Average | 0.904009E+10 | 0.115042E+10 | ||||||||
Minimum of Months | 0.403522E+09 | 2131.02 | 18.00 | 8.77 | 87558116.25 | 56.69 | 12.00 | 5.67 | ||
Maximum of Months | 0.122851E+10 | 2442.48 | 29.67 | 19.10 | 98643033.77 | 56.69 | 24.57 | 17.35 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.249172E+09 | 2080.44 | 14-JAN-16:01 | 23.00 | 12.39 | 95766706.78 | 56.69 | 24-JAN-22:19 | 16.00 | 11.53 |
February | 0.223998E+09 | 2154.49 | 01-FEB-09:02 | 22.33 | 11.83 | 86504215.98 | 56.69 | 15-FEB-22:10 | 13.83 | 12.18 |
March | 0.310439E+09 | 2136.04 | 11-MAR-16:01 | 21.33 | 12.79 | 96193052.56 | 56.69 | 23-MAR-21:19 | 13.67 | 13.09 |
April | 0.596750E+09 | 2182.57 | 26-APR-15:02 | 22.83 | 16.23 | 94089845.00 | 56.69 | 13-APR-01:10 | 13.00 | 13.00 |
May | 0.638337E+09 | 2174.66 | 24-MAY-08:62 | 18.00 | 8.77 | 97267723.85 | 56.69 | 02-MAY-21:49 | 17.00 | 15.07 |
June | 0.839089E+09 | 2110.00 | 21-JUN-15:02 | 22.00 | 16.40 | 94607475.08 | 56.69 | 28-JUN-21:00 | 17.00 | 16.37 |
July | 0.115874E+10 | 2158.36 | 23-JUL-08:62 | 23.33 | 19.10 | 98393859.75 | 56.69 | 25-JUL-22:00 | 18.00 | 17.35 |
August | 0.113902E+10 | 2140.82 | 19-AUG-18:02 | 22.67 | 17.48 | 98444302.79 | 56.69 | 11-AUG-21:40 | 17.00 | 16.37 |
September | 0.752166E+09 | 2171.07 | 30-SEP-18:02 | 22.67 | 16.86 | 94146309.20 | 56.69 | 29-SEP-21:10 | 24.58 | 13.49 |
October | 0.739669E+09 | 2406.66 | 15-OCT-08:62 | 29.67 | 14.34 | 97225792.30 | 56.69 | 04-OCT-21:40 | 21.00 | 18.97 |
November | 0.280865E+09 | 2314.79 | 19-NOV-09:02 | 24.33 | 12.75 | 92991062.01 | 56.69 | 10-NOV-22:10 | 15.00 | 13.80 |
December | 0.246983E+09 | 2305.38 | 05-DEC-09:02 | 24.33 | 11.99 | 95720836.60 | 56.69 | 05-DEC-23:10 | 17.33 | 9.19 |
Annual Sum or Average | 0.717523E+10 | 0.114135E+10 | ||||||||
Minimum of Months | 0.223998E+09 | 2080.44 | 18.00 | 8.77 | 86504215.98 | 56.69 | 13.00 | 9.19 | ||
Maximum of Months | 0.115874E+10 | 2406.66 | 29.67 | 19.10 | 98444302.79 | 56.69 | 24.58 | 18.97 |
Report: ZoneCoolingSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.247971E+10 | 1756.01 | 20-JAN-12:00 | 22.00 | 15.82 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.204451E+10 | 1736.88 | 01-FEB-13:20 | 22.33 | 14.87 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.207611E+10 | 1731.34 | 11-MAR-14:10 | 23.67 | 12.78 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.256465E+10 | 1717.39 | 26-APR-17:13 | 21.00 | 16.33 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.260152E+10 | 1719.37 | 04-MAY-14:00 | 23.00 | 16.65 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.295674E+10 | 1744.38 | 29-JUN-18:07 | 21.50 | 18.38 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.347817E+10 | 1764.51 | 19-JUL-18:50 | 21.33 | 18.46 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.357548E+10 | 1754.18 | 19-AUG-18:30 | 22.00 | 17.88 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.322308E+10 | 1830.27 | 30-SEP-14:40 | 32.00 | 17.25 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.350874E+10 | 1859.96 | 16-OCT-13:50 | 32.35 | 15.97 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.266565E+10 | 1784.00 | 19-NOV-13:10 | 26.67 | 14.98 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.262742E+10 | 1763.02 | 19-DEC-14:10 | 22.83 | 9.76 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.338018E+11 | 0.00 | ||||||||
Minimum of Months | 0.204451E+10 | 1717.39 | 21.00 | 9.76 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.357548E+10 | 1859.96 | 32.35 | 18.46 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.462958E+09 | 2737.56 | 14-JAN-16:01 | 23.00 | 12.39 | 97099116.83 | 56.69 | 30-JAN-22:10 | 12.83 | 11.71 |
February | 0.407510E+09 | 2689.03 | 03-FEB-16:01 | 20.50 | 10.02 | 87328616.73 | 56.69 | 15-FEB-22:10 | 13.83 | 12.18 |
March | 0.448197E+09 | 2744.73 | 11-MAR-16:01 | 21.33 | 12.79 | 96729032.40 | 56.69 | 24-MAR-21:10 | 13.00 | 11.77 |
April | 0.824913E+09 | 2707.06 | 01-APR-15:02 | 22.83 | 11.14 | 94562118.79 | 56.70 | 14-APR-04:19 | 14.00 | 13.03 |
May | 0.794436E+09 | 2581.23 | 17-MAY-15:02 | 21.67 | 15.71 | 97630244.31 | 56.70 | 23-MAY-02:00 | 14.00 | 11.72 |
June | 0.108149E+10 | 2657.98 | 30-JUN-15:02 | 22.95 | 17.84 | 94924468.34 | 56.69 | 29-JUN-22:00 | 17.00 | 17.00 |
July | 0.148633E+10 | 2758.01 | 19-JUL-15:02 | 26.67 | 20.19 | 98460826.91 | 56.69 | 27-JUL-23:49 | 18.00 | 17.35 |
August | 0.149394E+10 | 2744.89 | 18-AUG-15:02 | 26.50 | 20.70 | 98591607.18 | 56.69 | 23-AUG-22:10 | 16.83 | 16.21 |
September | 0.118057E+10 | 2617.74 | 13-SEP-15:02 | 22.83 | 18.36 | 95013486.21 | 56.70 | 16-SEP-02:20 | 13.00 | 12.44 |
October | 0.115987E+10 | 2898.52 | 15-OCT-15:02 | 30.83 | 15.36 | 97962094.18 | 56.69 | 15-OCT-23:49 | 21.67 | 10.97 |
November | 0.575315E+09 | 2648.15 | 19-NOV-09:02 | 24.33 | 12.75 | 94316621.93 | 56.70 | 01-NOV-03:49 | 12.12 | 9.02 |
December | 0.522557E+09 | 2749.38 | 05-DEC-16:01 | 22.67 | 12.39 | 97212045.35 | 56.70 | 05-DEC-01:00 | 18.00 | 10.33 |
Annual Sum or Average | 0.104381E+11 | 0.114983E+10 | ||||||||
Minimum of Months | 0.407510E+09 | 2581.23 | 20.50 | 10.02 | 87328616.73 | 56.69 | 12.12 | 9.02 | ||
Maximum of Months | 0.149394E+10 | 2898.52 | 30.83 | 20.70 | 98591607.18 | 56.70 | 21.67 | 17.35 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.192806E+09 | 2647.97 | 14-JAN-16:01 | 23.00 | 12.39 | 95602676.50 | 56.69 | 18-JAN-23:40 | 14.67 | 11.81 |
February | 0.210315E+09 | 2598.52 | 03-FEB-16:01 | 20.50 | 10.02 | 86445650.52 | 56.69 | 16-FEB-22:19 | 12.00 | 11.46 |
March | 0.301243E+09 | 2663.61 | 11-MAR-16:01 | 21.33 | 12.79 | 96064820.40 | 56.69 | 24-MAR-21:40 | 13.00 | 11.48 |
April | 0.699411E+09 | 2628.80 | 01-APR-15:02 | 22.83 | 11.14 | 94192913.63 | 56.70 | 09-APR-00:00 | 12.00 | 12.00 |
May | 0.771611E+09 | 2550.94 | 02-MAY-15:02 | 21.50 | 16.23 | 97566910.81 | 56.70 | 21-MAY-01:00 | 13.00 | 10.79 |
June | 0.109184E+10 | 2602.99 | 30-JUN-15:02 | 22.95 | 17.84 | 94929646.51 | 56.69 | 17-JUN-00:00 | 15.00 | 14.40 |
July | 0.147759E+10 | 2704.33 | 19-JUL-15:02 | 26.67 | 20.19 | 98450818.98 | 56.69 | 25-JUL-23:00 | 18.00 | 17.35 |
August | 0.139244E+10 | 2712.13 | 17-AUG-15:02 | 26.42 | 20.66 | 98468643.90 | 56.70 | 31-AUG-03:00 | 14.00 | 14.00 |
September | 0.969755E+09 | 2550.17 | 30-SEP-18:02 | 22.67 | 16.86 | 94614233.26 | 56.69 | 29-SEP-23:10 | 24.38 | 13.51 |
October | 0.830316E+09 | 2807.29 | 16-OCT-15:02 | 29.83 | 15.94 | 97336597.20 | 56.70 | 07-OCT-00:00 | 16.00 | 13.01 |
November | 0.251639E+09 | 2529.46 | 27-NOV-16:01 | 19.67 | 7.52 | 93190887.51 | 56.70 | 10-NOV-23:49 | 14.17 | 12.99 |
December | 0.197417E+09 | 2658.74 | 05-DEC-16:01 | 22.67 | 12.39 | 95668101.19 | 56.69 | 04-DEC-22:40 | 16.67 | 9.76 |
Annual Sum or Average | 0.838638E+10 | 0.114253E+10 | ||||||||
Minimum of Months | 0.192806E+09 | 2529.46 | 19.67 | 7.52 | 86445650.52 | 56.69 | 12.00 | 9.76 | ||
Maximum of Months | 0.147759E+10 | 2807.29 | 29.83 | 20.66 | 98468643.90 | 56.70 | 24.38 | 17.35 |
Report: ZoneCoolingSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.833110E+09 | 1402.54 | 14-JAN-16:01 | 23.00 | 12.39 | 98245064.41 | 56.69 | 20-JAN-22:49 | 13.83 | 13.83 |
February | 0.563347E+09 | 1367.25 | 03-FEB-16:01 | 20.50 | 10.02 | 88195189.69 | 56.69 | 16-FEB-22:10 | 12.00 | 11.46 |
March | 0.468276E+09 | 1380.35 | 10-MAR-16:01 | 21.67 | 12.37 | 97386566.38 | 56.69 | 24-MAR-21:10 | 13.00 | 11.77 |
April | 0.514690E+09 | 1370.69 | 01-APR-15:02 | 22.83 | 11.14 | 94570157.19 | 56.69 | 11-APR-21:10 | 13.83 | 13.83 |
May | 0.401335E+09 | 1312.11 | 03-MAY-15:02 | 21.83 | 15.31 | 97024967.86 | 56.69 | 03-MAY-23:40 | 16.00 | 13.76 |
June | 0.497737E+09 | 1265.08 | 30-JUN-15:02 | 22.95 | 17.84 | 94200180.85 | 56.69 | 30-JUN-22:49 | 16.27 | 15.75 |
July | 0.689225E+09 | 1292.68 | 19-JUL-15:02 | 26.67 | 20.19 | 97900459.96 | 56.69 | 31-JUL-21:19 | 18.90 | 17.79 |
August | 0.799591E+09 | 1325.48 | 19-AUG-15:02 | 25.83 | 18.85 | 98310553.20 | 56.69 | 14-AUG-21:30 | 18.50 | 17.51 |
September | 0.810848E+09 | 1326.51 | 11-SEP-15:02 | 22.00 | 16.75 | 94942052.20 | 56.69 | 29-SEP-23:10 | 24.38 | 13.51 |
October | 0.103867E+10 | 1461.68 | 16-OCT-15:02 | 29.83 | 15.94 | 98300220.32 | 56.69 | 13-OCT-21:00 | 18.00 | 10.60 |
November | 0.833987E+09 | 1407.17 | 19-NOV-09:02 | 24.33 | 12.75 | 95221843.88 | 56.69 | 30-NOV-22:10 | 11.52 | 5.70 |
December | 0.911387E+09 | 1403.11 | 05-DEC-16:01 | 22.67 | 12.39 | 98339220.70 | 56.69 | 05-DEC-23:10 | 17.33 | 9.19 |
Annual Sum or Average | 0.836220E+10 | 0.115264E+10 | ||||||||
Minimum of Months | 0.401335E+09 | 1265.08 | 20.50 | 10.02 | 88195189.69 | 56.69 | 11.52 | 5.70 | ||
Maximum of Months | 0.103867E+10 | 1461.68 | 29.83 | 20.19 | 98339220.70 | 56.69 | 24.38 | 17.79 |
Report: ZoneCoolingSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.366850E+11 | 18835.07 | 09-JAN-05:55 | 2.00 | -0.1 | 0.182705E+11 | 11347.82 | 31-JAN-04:19 | 12.00 | 12.00 |
February | 0.329150E+11 | 18450.60 | 15-FEB-23:00 | 13.00 | 11.87 | 0.168507E+11 | 11347.85 | 28-FEB-04:19 | 11.00 | 8.84 |
March | 0.368855E+11 | 18726.67 | 24-MAR-22:00 | 13.00 | 11.28 | 0.186039E+11 | 11347.90 | 20-MAR-00:20 | 10.67 | 10.12 |
April | 0.371042E+11 | 19300.05 | 26-APR-22:00 | 16.00 | 15.39 | 0.181821E+11 | 11348.02 | 17-APR-00:20 | 10.67 | 9.23 |
May | 0.387720E+11 | 19661.11 | 04-MAY-22:00 | 17.00 | 15.07 | 0.187925E+11 | 11348.07 | 15-MAY-00:20 | 10.00 | 9.41 |
June | 0.390251E+11 | 19842.93 | 27-JUN-22:00 | 17.00 | 16.37 | 0.182164E+11 | 11347.81 | 02-JUN-03:20 | 13.33 | 12.58 |
July | 0.413264E+11 | 20043.98 | 19-JUL-22:00 | 18.00 | 17.35 | 0.187362E+11 | 11347.62 | 14-JUL-03:20 | 15.33 | 14.93 |
August | 0.412885E+11 | 19911.67 | 18-AUG-22:00 | 19.00 | 17.66 | 0.188035E+11 | 11347.55 | 29-AUG-03:20 | 16.00 | 14.76 |
September | 0.386598E+11 | 20428.82 | 29-SEP-22:00 | 24.50 | 13.59 | 0.180895E+11 | 11347.75 | 21-SEP-22:19 | 22.00 | 19.92 |
October | 0.397007E+11 | 20134.99 | 16-OCT-22:00 | 20.00 | 11.07 | 0.186140E+11 | 11347.82 | 03-OCT-22:19 | 20.00 | 18.02 |
November | 0.357517E+11 | 18525.64 | 01-NOV-22:00 | 14.00 | 11.20 | 0.180057E+11 | 11347.92 | 03-NOV-03:20 | 9.67 | 6.86 |
December | 0.365883E+11 | 18681.37 | 05-DEC-23:00 | 18.00 | 9.34 | 0.183907E+11 | 11348.68 | 01-DEC-00:49 | 10.37 | 9.40 |
Annual Sum or Average | 0.454702E+12 | 0.219556E+12 | ||||||||
Minimum of Months | 0.329150E+11 | 18450.60 | 2.00 | -0.1 | 0.168507E+11 | 11347.55 | 9.67 | 6.86 | ||
Maximum of Months | 0.413264E+11 | 20428.82 | 24.50 | 17.66 | 0.188035E+11 | 11348.68 | 22.00 | 19.92 |
Report: ZoneCoolingSummaryMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.401183E+11 | 20333.69 | 18-JAN-22:10 | 16.83 | 13.40 | 0.185044E+11 | 11348.09 | 02-JAN-23:19 | 6.33 | 4.91 |
February | 0.361664E+11 | 20349.63 | 15-FEB-23:00 | 13.00 | 11.87 | 0.170302E+11 | 11347.90 | 28-FEB-04:19 | 11.00 | 8.84 |
March | 0.404922E+11 | 20535.91 | 24-MAR-22:00 | 13.00 | 11.28 | 0.188252E+11 | 11348.10 | 07-MAR-23:19 | 6.33 | 5.21 |
April | 0.406731E+11 | 21109.44 | 26-APR-22:00 | 16.00 | 15.39 | 0.183460E+11 | 11348.04 | 17-APR-00:20 | 10.67 | 9.23 |
May | 0.425045E+11 | 21418.59 | 04-MAY-22:00 | 17.00 | 15.07 | 0.189607E+11 | 11348.09 | 15-MAY-00:20 | 10.00 | 9.41 |
June | 0.425808E+11 | 21592.77 | 27-JUN-22:00 | 17.00 | 16.37 | 0.183637E+11 | 11347.84 | 02-JUN-03:20 | 13.33 | 12.58 |
July | 0.448610E+11 | 21772.03 | 19-JUL-22:00 | 18.00 | 17.35 | 0.188833E+11 | 11347.65 | 14-JUL-03:20 | 15.33 | 14.93 |
August | 0.447650E+11 | 21596.83 | 18-AUG-22:00 | 19.00 | 17.66 | 0.189465E+11 | 11347.58 | 29-AUG-03:20 | 16.00 | 14.76 |
September | 0.420774E+11 | 22120.83 | 29-SEP-21:10 | 24.58 | 13.49 | 0.182546E+11 | 11347.77 | 21-SEP-22:19 | 22.00 | 19.92 |
October | 0.431154E+11 | 21713.80 | 16-OCT-22:00 | 20.00 | 11.07 | 0.187845E+11 | 11347.84 | 03-OCT-22:19 | 20.00 | 18.02 |
November | 0.391686E+11 | 20316.77 | 01-NOV-22:00 | 14.00 | 11.20 | 0.181879E+11 | 11347.96 | 03-NOV-03:20 | 9.67 | 6.86 |
December | 0.400142E+11 | 20487.38 | 05-DEC-23:00 | 18.00 | 9.34 | 0.186183E+11 | 11348.99 | 01-DEC-00:49 | 10.37 | 9.40 |
Annual Sum or Average | 0.496537E+12 | 0.221705E+12 | ||||||||
Minimum of Months | 0.361664E+11 | 20316.77 | 13.00 | 9.34 | 0.170302E+11 | 11347.58 | 6.33 | 4.91 | ||
Maximum of Months | 0.448610E+11 | 22120.83 | 24.58 | 17.66 | 0.189607E+11 | 11348.99 | 22.00 | 19.92 |
Report: ZoneCoolingSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.530608E+11 | 28443.84 | 14-JAN-11:50 | 26.00 | 11.75 | 0.187607E+11 | 11362.59 | 07-JAN-18:00 | 11.00 | 9.85 |
February | 0.478157E+11 | 28120.51 | 01-FEB-11:50 | 25.50 | 14.46 | 0.169719E+11 | 11358.83 | 25-FEB-18:00 | 11.00 | 9.85 |
March | 0.532055E+11 | 28895.85 | 12-MAR-10:40 | 21.33 | 14.68 | 0.187836E+11 | 11373.97 | 04-MAR-18:40 | 9.67 | 8.91 |
April | 0.528306E+11 | 29184.96 | 30-APR-10:50 | 25.83 | 17.11 | 0.181945E+11 | 11344.72 | 22-APR-17:00 | 13.00 | 11.29 |
May | 0.545878E+11 | 28777.79 | 02-MAY-10:40 | 21.67 | 15.54 | 0.187977E+11 | 11340.18 | 13-MAY-17:00 | 14.00 | 10.67 |
June | 0.538261E+11 | 29039.32 | 25-JUN-10:40 | 23.00 | 17.25 | 0.181800E+11 | 11319.55 | 10-JUN-17:19 | 17.67 | 14.81 |
July | 0.564988E+11 | 29395.20 | 23-JUL-10:50 | 25.83 | 20.42 | 0.187684E+11 | 11319.58 | 01-JUL-17:19 | 20.33 | 16.97 |
August | 0.565810E+11 | 29258.81 | 15-AUG-10:40 | 27.00 | 20.83 | 0.187722E+11 | 11319.58 | 19-AUG-17:19 | 23.67 | 17.51 |
September | 0.537581E+11 | 29782.48 | 30-SEP-10:40 | 30.57 | 17.20 | 0.181673E+11 | 11319.56 | 16-SEP-17:19 | 17.33 | 14.50 |
October | 0.552002E+11 | 29820.37 | 15-OCT-10:40 | 31.67 | 16.40 | 0.187736E+11 | 11319.56 | 28-OCT-17:19 | 16.67 | 14.38 |
November | 0.516387E+11 | 28955.13 | 19-NOV-11:50 | 26.00 | 15.36 | 0.181830E+11 | 11354.06 | 04-NOV-17:00 | 12.00 | 9.28 |
December | 0.530152E+11 | 28217.47 | 17-DEC-11:50 | 22.67 | 9.66 | 0.187667E+11 | 11372.96 | 30-DEC-18:00 | 10.00 | 9.41 |
Annual Sum or Average | 0.642019E+12 | 0.221119E+12 | ||||||||
Minimum of Months | 0.478157E+11 | 28120.51 | 21.33 | 9.66 | 0.169719E+11 | 11319.55 | 9.67 | 8.91 | ||
Maximum of Months | 0.565810E+11 | 29820.37 | 31.67 | 20.83 | 0.187977E+11 | 11373.97 | 23.67 | 17.51 |
Report: ZoneCoolingSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.588389E+10 | 3598.74 | 14-JAN-14:20 | 24.67 | 13.36 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.533611E+10 | 3534.64 | 01-FEB-13:10 | 23.17 | 14.39 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.569028E+10 | 3595.93 | 11-MAR-13:20 | 24.00 | 13.44 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.679869E+10 | 3602.44 | 26-APR-13:50 | 26.17 | 16.79 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.710507E+10 | 3639.47 | 04-MAY-12:30 | 23.50 | 16.60 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.773905E+10 | 3638.24 | 30-JUN-13:50 | 23.00 | 17.84 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.869390E+10 | 3741.54 | 30-JUL-13:40 | 24.00 | 19.50 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.877191E+10 | 3757.52 | 19-AUG-14:00 | 27.00 | 20.16 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.793963E+10 | 4031.64 | 30-SEP-14:00 | 32.00 | 17.58 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.819542E+10 | 4056.92 | 16-OCT-13:20 | 33.40 | 16.45 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.637185E+10 | 3731.24 | 19-NOV-13:10 | 26.67 | 14.98 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.612629E+10 | 3657.08 | 19-DEC-13:20 | 25.00 | 10.98 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.846521E+11 | 0.00 | ||||||||
Minimum of Months | 0.533611E+10 | 3534.64 | 23.00 | 10.98 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.877191E+10 | 4056.92 | 33.40 | 20.16 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneHeatingSummaryMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 2023837.04 | 251.18 | 30-MAR-07:03 | 7.33 |
April | 39492.90 | 53.63 | 01-APR-06:05 | 7.67 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 25740.96 | 24.23 | 13-DEC-04:30 | 7.00 |
Annual Sum or Average | 2089070.90 | |||
Minimum of Months | 0.00 | 0.00 | 7.00 | |
Maximum of Months | 2023837.04 | 251.18 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 75036728.98 | 918.17 | 01-JAN-19:03 | 11.00 |
February | 50063397.52 | 961.20 | 25-FEB-16:02 | 11.00 |
March | 90150319.45 | 954.26 | 30-MAR-08:62 | 9.50 |
April | 11654114.25 | 725.18 | 09-APR-08:03 | 12.67 |
May | 8684434.32 | 552.03 | 04-MAY-08:03 | 19.17 |
June | 896891.59 | 496.65 | 22-JUN-08:03 | 19.33 |
July | 554783.35 | 534.04 | 23-JUL-08:05 | 23.33 |
August | 701380.58 | 508.27 | 31-AUG-08:03 | 20.50 |
September | 899659.47 | 500.47 | 13-SEP-08:03 | 20.33 |
October | 2857841.36 | 792.05 | 14-OCT-08:04 | 27.67 |
November | 22434802.42 | 605.76 | 19-NOV-09:05 | 24.33 |
December | 56826544.02 | 892.59 | 12-DEC-19:03 | 9.67 |
Annual Sum or Average | 0.320761E+09 | |||
Minimum of Months | 554783.35 | 496.65 | 9.50 | |
Maximum of Months | 90150319.45 | 961.20 | 27.67 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.170250E+09 | 968.86 | 03-JAN-09:02 | 11.33 |
February | 89428083.90 | 960.64 | 25-FEB-16:02 | 11.00 |
March | 0.123086E+09 | 955.42 | 08-MAR-09:02 | 13.33 |
April | 15544732.19 | 843.57 | 01-APR-08:62 | 15.67 |
May | 8860689.98 | 562.35 | 14-MAY-08:03 | 15.17 |
June | 783924.46 | 474.97 | 04-JUN-08:04 | 17.17 |
July | 496152.79 | 529.95 | 23-JUL-08:05 | 23.33 |
August | 686439.67 | 463.61 | 30-AUG-08:03 | 19.50 |
September | 1037831.56 | 449.43 | 30-SEP-08:05 | 25.38 |
October | 7406376.74 | 916.78 | 30-OCT-08:62 | 17.67 |
November | 61672800.53 | 935.85 | 05-NOV-08:62 | 11.33 |
December | 0.142982E+09 | 969.20 | 15-DEC-09:02 | 12.33 |
Annual Sum or Average | 0.622235E+09 | |||
Minimum of Months | 496152.79 | 449.43 | 11.00 | |
Maximum of Months | 0.170250E+09 | 969.20 | 25.38 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 1462721.73 | 259.29 | 10-JAN-16:02 | 13.83 |
February | 948726.91 | 272.92 | 18-FEB-16:03 | 15.83 |
March | 974684.08 | 270.27 | 20-MAR-15:05 | 15.67 |
April | 553901.71 | 261.92 | 19-APR-15:03 | 17.17 |
May | 516590.59 | 236.62 | 12-MAY-15:07 | 15.83 |
June | 298230.10 | 194.23 | 06-JUN-15:05 | 17.83 |
July | 197538.22 | 139.61 | 31-JUL-08:05 | 21.33 |
August | 226373.56 | 169.73 | 14-AUG-08:05 | 23.33 |
September | 212973.14 | 176.41 | 23-SEP-15:05 | 19.00 |
October | 285711.95 | 264.92 | 23-OCT-15:04 | 17.00 |
November | 1105660.86 | 267.34 | 12-NOV-16:03 | 16.67 |
December | 1111397.37 | 259.21 | 13-DEC-16:02 | 12.83 |
Annual Sum or Average | 7894510.22 | |||
Minimum of Months | 197538.22 | 139.61 | 12.83 | |
Maximum of Months | 1462721.73 | 272.92 | 23.33 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 74815504.55 | 876.66 | 01-JAN-19:03 | 11.00 |
February | 59997737.15 | 922.83 | 25-FEB-16:02 | 11.00 |
March | 99804034.67 | 902.38 | 28-MAR-08:62 | 9.33 |
April | 14123911.19 | 604.42 | 22-APR-15:03 | 16.83 |
May | 13581677.97 | 598.56 | 26-MAY-18:03 | 13.83 |
June | 1349156.27 | 467.62 | 07-JUN-18:03 | 16.83 |
July | 524612.78 | 402.00 | 09-JUL-15:05 | 21.83 |
August | 441960.87 | 340.12 | 04-AUG-18:05 | 19.67 |
September | 969851.60 | 482.71 | 19-SEP-15:05 | 18.83 |
October | 3586592.81 | 612.30 | 23-OCT-15:04 | 17.00 |
November | 29560359.99 | 775.26 | 22-NOV-16:04 | 15.67 |
December | 63944481.05 | 883.53 | 12-DEC-16:03 | 12.00 |
Annual Sum or Average | 0.362700E+09 | |||
Minimum of Months | 441960.87 | 340.12 | 9.33 | |
Maximum of Months | 99804034.67 | 922.83 | 21.83 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.164131E+09 | 925.66 | 02-JAN-16:02 | 12.67 |
February | 0.108780E+09 | 925.70 | 25-FEB-16:02 | 11.00 |
March | 0.136884E+09 | 901.32 | 28-MAR-08:62 | 9.33 |
April | 20026415.30 | 620.75 | 15-APR-15:03 | 17.00 |
May | 14419760.25 | 502.59 | 13-MAY-15:05 | 16.17 |
June | 1428225.93 | 436.24 | 02-JUN-15:05 | 20.67 |
July | 522090.26 | 375.42 | 09-JUL-15:05 | 21.83 |
August | 495478.60 | 380.18 | 22-AUG-15:05 | 20.83 |
September | 1888205.17 | 548.38 | 21-SEP-15:05 | 27.67 |
October | 9613509.58 | 541.02 | 21-OCT-15:03 | 19.67 |
November | 77241821.47 | 896.53 | 24-NOV-16:02 | 15.83 |
December | 0.152944E+09 | 921.95 | 13-DEC-16:02 | 12.83 |
Annual Sum or Average | 0.688375E+09 | |||
Minimum of Months | 495478.60 | 375.42 | 9.33 | |
Maximum of Months | 0.164131E+09 | 925.70 | 27.67 |
Report: ZoneHeatingSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 602587.86 | 71.75 | 02-JAN-04:40 | 10.67 |
February | 328862.12 | 42.76 | 26-FEB-04:40 | 10.67 |
March | 708855.39 | 225.37 | 30-MAR-08:62 | 9.50 |
April | 642013.59 | 167.66 | 01-APR-06:25 | 9.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 50801.63 | 15.03 | 14-DEC-05:00 | 8.00 |
Annual Sum or Average | 2333120.59 | |||
Minimum of Months | 0.00 | 0.00 | 8.00 | |
Maximum of Months | 708855.39 | 225.37 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.168947E+09 | 1111.21 | 03-JAN-09:02 | 11.33 |
February | 0.124768E+09 | 1148.25 | 25-FEB-16:02 | 11.00 |
March | 0.184153E+09 | 1142.88 | 30-MAR-08:62 | 9.50 |
April | 30328136.98 | 1118.71 | 01-APR-08:62 | 15.67 |
May | 24916428.56 | 720.50 | 20-MAY-08:04 | 15.17 |
June | 2150451.14 | 513.68 | 06-JUN-15:05 | 17.83 |
July | 426054.09 | 542.77 | 23-JUL-08:05 | 23.33 |
August | 570702.26 | 474.47 | 31-AUG-08:03 | 20.50 |
September | 640437.09 | 432.84 | 13-SEP-08:03 | 20.33 |
October | 11690312.38 | 747.30 | 14-OCT-08:04 | 27.67 |
November | 69834785.76 | 584.79 | 24-NOV-09:03 | 14.17 |
December | 0.141978E+09 | 1111.96 | 13-DEC-09:02 | 11.33 |
Annual Sum or Average | 0.760404E+09 | |||
Minimum of Months | 426054.09 | 432.84 | 9.50 | |
Maximum of Months | 0.184153E+09 | 1148.25 | 27.67 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.332059E+09 | 1160.14 | 03-JAN-09:02 | 11.33 |
February | 0.201806E+09 | 1149.52 | 25-FEB-16:02 | 11.00 |
March | 0.243235E+09 | 1141.58 | 30-MAR-08:62 | 9.50 |
April | 40594311.26 | 1118.63 | 01-APR-08:62 | 15.67 |
May | 25791211.31 | 689.78 | 20-MAY-08:04 | 15.17 |
June | 2181099.38 | 513.25 | 06-JUN-15:05 | 17.83 |
July | 436291.03 | 574.65 | 23-JUL-08:05 | 23.33 |
August | 645371.50 | 468.30 | 30-AUG-08:03 | 19.50 |
September | 1443197.41 | 428.60 | 06-SEP-08:03 | 19.33 |
October | 26062319.62 | 1099.34 | 12-OCT-08:62 | 16.50 |
November | 0.150114E+09 | 1120.98 | 05-NOV-08:62 | 11.33 |
December | 0.293357E+09 | 1159.67 | 15-DEC-09:02 | 12.33 |
Annual Sum or Average | 0.131772E+10 | |||
Minimum of Months | 436291.03 | 428.60 | 9.50 | |
Maximum of Months | 0.332059E+09 | 1160.14 | 23.33 |
Report: ZoneHeatingSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 7845085.06 | 223.65 | 01-JAN-16:05 | 12.67 |
February | 7329728.06 | 566.32 | 25-FEB-16:02 | 11.00 |
March | 30799162.89 | 567.16 | 30-MAR-08:62 | 9.50 |
April | 3679137.04 | 323.63 | 18-APR-15:05 | 16.00 |
May | 5752565.30 | 469.23 | 12-MAY-15:07 | 15.83 |
June | 609988.18 | 312.55 | 06-JUN-15:05 | 17.83 |
July | 326209.99 | 285.86 | 15-JUL-08:05 | 19.50 |
August | 235897.26 | 235.76 | 05-AUG-08:05 | 19.50 |
September | 163454.77 | 207.49 | 20-SEP-08:03 | 16.33 |
October | 264794.06 | 234.84 | 23-OCT-15:06 | 17.00 |
November | 332696.41 | 231.00 | 24-NOV-16:06 | 15.83 |
December | 4121453.83 | 161.00 | 13-DEC-04:30 | 7.00 |
Annual Sum or Average | 61460172.86 | |||
Minimum of Months | 163454.77 | 161.00 | 7.00 | |
Maximum of Months | 30799162.89 | 567.16 | 19.50 |
Report: ZoneHeatingSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneHeatingSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 3946229.86 | 322.24 | 09-JAN-07:35 | 5.67 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 13.23 |
March | 6356452.90 | 518.77 | 07-MAR-05:50 | 6.50 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 490284.08 | 86.01 | 13-DEC-04:30 | 7.00 |
Annual Sum or Average | 10792966.85 | |||
Minimum of Months | 0.00 | 0.00 | 5.67 | |
Maximum of Months | 6356452.90 | 518.77 | 18.42 |
Report: ZoneElectricSummaryMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.144724E+11 | 13939.86 | 02-JAN-20:10 | 0.127587E+11 | 10113.80 | 02-JAN-20:10 |
February | 0.130672E+11 | 13939.86 | 01-FEB-20:10 | 0.115208E+11 | 10113.80 | 01-FEB-20:10 |
March | 0.145225E+11 | 13939.86 | 01-MAR-20:10 | 0.127894E+11 | 10113.80 | 01-MAR-20:10 |
April | 0.139817E+11 | 13939.86 | 03-APR-19:10 | 0.123314E+11 | 10113.80 | 03-APR-19:10 |
May | 0.144975E+11 | 13939.86 | 01-MAY-19:10 | 0.127741E+11 | 10113.80 | 01-MAY-19:10 |
June | 0.140458E+11 | 13939.86 | 01-JUN-19:10 | 0.123716E+11 | 10113.80 | 01-JUN-19:10 |
July | 0.144333E+11 | 13939.86 | 03-JUL-19:10 | 0.127338E+11 | 10113.80 | 03-JUL-19:10 |
August | 0.145225E+11 | 13939.86 | 01-AUG-19:10 | 0.127894E+11 | 10113.80 | 01-AUG-19:10 |
September | 0.139817E+11 | 13939.86 | 01-SEP-19:10 | 0.123314E+11 | 10113.80 | 01-SEP-19:10 |
October | 0.144724E+11 | 13939.86 | 02-OCT-19:10 | 0.127587E+11 | 10113.80 | 02-OCT-19:10 |
November | 0.140346E+11 | 13939.86 | 01-NOV-19:10 | 0.123659E+11 | 10113.80 | 01-NOV-19:10 |
December | 0.144333E+11 | 13939.86 | 01-DEC-20:10 | 0.127338E+11 | 10113.80 | 01-DEC-20:10 |
Annual Sum or Average | 0.170465E+12 | 0.150259E+12 | ||||
Minimum of Months | 0.130672E+11 | 13939.86 | 0.115208E+11 | 10113.80 | ||
Maximum of Months | 0.145225E+11 | 13939.86 | 0.127894E+11 | 10113.80 |
Report: ZoneElectricSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.764969E+09 | 736.82 | 02-JAN-20:10 | 0.864900E+09 | 685.60 | 02-JAN-20:10 |
February | 0.690697E+09 | 736.82 | 01-FEB-20:10 | 0.780982E+09 | 685.60 | 01-FEB-20:10 |
March | 0.767621E+09 | 736.82 | 01-MAR-20:10 | 0.866978E+09 | 685.60 | 01-MAR-20:10 |
April | 0.739033E+09 | 736.82 | 03-APR-19:10 | 0.835931E+09 | 685.60 | 03-APR-19:10 |
May | 0.766295E+09 | 736.82 | 01-MAY-19:10 | 0.865939E+09 | 685.60 | 01-MAY-19:10 |
June | 0.742422E+09 | 736.82 | 01-JUN-19:10 | 0.838659E+09 | 685.60 | 01-JUN-19:10 |
July | 0.762906E+09 | 736.82 | 03-JUL-19:10 | 0.863211E+09 | 685.60 | 03-JUL-19:10 |
August | 0.767621E+09 | 736.82 | 01-AUG-19:10 | 0.866978E+09 | 685.60 | 01-AUG-19:10 |
September | 0.739033E+09 | 736.82 | 01-SEP-19:10 | 0.835931E+09 | 685.60 | 01-SEP-19:10 |
October | 0.764969E+09 | 736.82 | 02-OCT-19:10 | 0.864900E+09 | 685.60 | 02-OCT-19:10 |
November | 0.741833E+09 | 736.82 | 01-NOV-19:10 | 0.838269E+09 | 685.60 | 01-NOV-19:10 |
December | 0.762906E+09 | 736.82 | 01-DEC-20:10 | 0.863211E+09 | 685.60 | 01-DEC-20:10 |
Annual Sum or Average | 0.901031E+10 | 0.101859E+11 | ||||
Minimum of Months | 0.690697E+09 | 736.82 | 0.780982E+09 | 685.60 | ||
Maximum of Months | 0.767621E+09 | 736.82 | 0.866978E+09 | 685.60 |
Report: ZoneElectricSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.885837E+09 | 853.24 | 02-JAN-20:10 | 0.100156E+10 | 793.93 | 02-JAN-20:10 |
February | 0.799830E+09 | 853.24 | 01-FEB-20:10 | 0.904380E+09 | 793.93 | 01-FEB-20:10 |
March | 0.888909E+09 | 853.24 | 01-MAR-20:10 | 0.100396E+10 | 793.93 | 01-MAR-20:10 |
April | 0.855803E+09 | 853.24 | 03-APR-19:10 | 0.968011E+09 | 793.93 | 03-APR-19:10 |
May | 0.887373E+09 | 853.24 | 01-MAY-19:10 | 0.100276E+10 | 793.93 | 01-MAY-19:10 |
June | 0.859728E+09 | 853.24 | 01-JUN-19:10 | 0.971170E+09 | 793.93 | 01-JUN-19:10 |
July | 0.883448E+09 | 853.24 | 03-JUL-19:10 | 0.999601E+09 | 793.93 | 03-JUL-19:10 |
August | 0.888909E+09 | 853.24 | 01-AUG-19:10 | 0.100396E+10 | 793.93 | 01-AUG-19:10 |
September | 0.855803E+09 | 853.24 | 01-SEP-19:10 | 0.968011E+09 | 793.93 | 01-SEP-19:10 |
October | 0.885837E+09 | 853.24 | 02-OCT-19:10 | 0.100156E+10 | 793.93 | 02-OCT-19:10 |
November | 0.859045E+09 | 853.24 | 01-NOV-19:10 | 0.970719E+09 | 793.93 | 01-NOV-19:10 |
December | 0.883448E+09 | 853.24 | 01-DEC-20:10 | 0.999601E+09 | 793.93 | 01-DEC-20:10 |
Annual Sum or Average | 0.104340E+11 | 0.117953E+11 | ||||
Minimum of Months | 0.799830E+09 | 853.24 | 0.904380E+09 | 793.93 | ||
Maximum of Months | 0.888909E+09 | 853.24 | 0.100396E+10 | 793.93 |
Report: ZoneElectricSummaryMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.141237E+10 | 1360.40 | 02-JAN-20:10 | 0.105898E+10 | 839.45 | 02-JAN-20:10 |
February | 0.127524E+10 | 1360.40 | 01-FEB-20:10 | 0.956227E+09 | 839.45 | 01-FEB-20:10 |
March | 0.141726E+10 | 1360.40 | 01-MAR-20:10 | 0.106152E+10 | 839.45 | 01-MAR-20:10 |
April | 0.136448E+10 | 1360.40 | 03-APR-19:10 | 0.102351E+10 | 839.45 | 03-APR-19:10 |
May | 0.141481E+10 | 1360.40 | 01-MAY-19:10 | 0.106025E+10 | 839.45 | 01-MAY-19:10 |
June | 0.137074E+10 | 1360.40 | 01-JUN-19:10 | 0.102685E+10 | 839.45 | 01-JUN-19:10 |
July | 0.140856E+10 | 1360.40 | 03-JUL-19:10 | 0.105691E+10 | 839.45 | 03-JUL-19:10 |
August | 0.141726E+10 | 1360.40 | 01-AUG-19:10 | 0.106152E+10 | 839.45 | 01-AUG-19:10 |
September | 0.136448E+10 | 1360.40 | 01-SEP-19:10 | 0.102351E+10 | 839.45 | 01-SEP-19:10 |
October | 0.141237E+10 | 1360.40 | 02-OCT-19:10 | 0.105898E+10 | 839.45 | 02-OCT-19:10 |
November | 0.136965E+10 | 1360.40 | 01-NOV-19:10 | 0.102637E+10 | 839.45 | 01-NOV-19:10 |
December | 0.140856E+10 | 1360.40 | 01-DEC-20:10 | 0.105691E+10 | 839.45 | 01-DEC-20:10 |
Annual Sum or Average | 0.166358E+11 | 0.124715E+11 | ||||
Minimum of Months | 0.127524E+10 | 1360.40 | 0.956227E+09 | 839.45 | ||
Maximum of Months | 0.141726E+10 | 1360.40 | 0.106152E+10 | 839.45 |
Report: ZoneElectricSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.280997E+09 | 270.66 | 02-JAN-20:10 | 0.305485E+09 | 242.16 | 02-JAN-20:10 |
February | 0.253715E+09 | 270.66 | 01-FEB-20:10 | 0.275845E+09 | 242.16 | 01-FEB-20:10 |
March | 0.281971E+09 | 270.66 | 01-MAR-20:10 | 0.306219E+09 | 242.16 | 01-MAR-20:10 |
April | 0.271470E+09 | 270.66 | 03-APR-19:10 | 0.295253E+09 | 242.16 | 03-APR-19:10 |
May | 0.281484E+09 | 270.66 | 01-MAY-19:10 | 0.305852E+09 | 242.16 | 01-MAY-19:10 |
June | 0.272715E+09 | 270.66 | 01-JUN-19:10 | 0.296217E+09 | 242.16 | 01-JUN-19:10 |
July | 0.280239E+09 | 270.66 | 03-JUL-19:10 | 0.304889E+09 | 242.16 | 03-JUL-19:10 |
August | 0.281971E+09 | 270.66 | 01-AUG-19:10 | 0.306219E+09 | 242.16 | 01-AUG-19:10 |
September | 0.271470E+09 | 270.66 | 01-SEP-19:10 | 0.295253E+09 | 242.16 | 01-SEP-19:10 |
October | 0.280997E+09 | 270.66 | 02-OCT-19:10 | 0.305485E+09 | 242.16 | 02-OCT-19:10 |
November | 0.272498E+09 | 270.66 | 01-NOV-19:10 | 0.296079E+09 | 242.16 | 01-NOV-19:10 |
December | 0.280239E+09 | 270.66 | 01-DEC-20:10 | 0.304889E+09 | 242.16 | 01-DEC-20:10 |
Annual Sum or Average | 0.330977E+10 | 0.359769E+10 | ||||
Minimum of Months | 0.253715E+09 | 270.66 | 0.275845E+09 | 242.16 | ||
Maximum of Months | 0.281971E+09 | 270.66 | 0.306219E+09 | 242.16 |
Report: ZoneElectricSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.423840E+09 | 408.24 | 02-JAN-20:10 | 0.576866E+10 | 4572.80 | 02-JAN-20:10 |
February | 0.382689E+09 | 408.24 | 01-FEB-20:10 | 0.520895E+10 | 4572.80 | 01-FEB-20:10 |
March | 0.425309E+09 | 408.24 | 01-MAR-20:10 | 0.578252E+10 | 4572.80 | 01-MAR-20:10 |
April | 0.409470E+09 | 408.24 | 03-APR-19:10 | 0.557545E+10 | 4572.80 | 03-APR-19:10 |
May | 0.424575E+09 | 408.24 | 01-MAY-19:10 | 0.577559E+10 | 4572.80 | 01-MAY-19:10 |
June | 0.411347E+09 | 408.24 | 01-JUN-19:10 | 0.559364E+10 | 4572.80 | 01-JUN-19:10 |
July | 0.422697E+09 | 408.24 | 03-JUL-19:10 | 0.575740E+10 | 4572.80 | 03-JUL-19:10 |
August | 0.425309E+09 | 408.24 | 01-AUG-19:10 | 0.578252E+10 | 4572.80 | 01-AUG-19:10 |
September | 0.409470E+09 | 408.24 | 01-SEP-19:10 | 0.557545E+10 | 4572.80 | 01-SEP-19:10 |
October | 0.423840E+09 | 408.24 | 02-OCT-19:10 | 0.576866E+10 | 4572.80 | 02-OCT-19:10 |
November | 0.411021E+09 | 408.24 | 01-NOV-19:10 | 0.559104E+10 | 4572.80 | 01-NOV-19:10 |
December | 0.422697E+09 | 408.24 | 01-DEC-20:10 | 0.575740E+10 | 4572.80 | 01-DEC-20:10 |
Annual Sum or Average | 0.499226E+10 | 0.679373E+11 | ||||
Minimum of Months | 0.382689E+09 | 408.24 | 0.520895E+10 | 4572.80 | ||
Maximum of Months | 0.425309E+09 | 408.24 | 0.578252E+10 | 4572.80 |
Report: ZoneElectricSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.158799E+10 | 1761.91 | 02-JAN-20:10 | 0.121771E+10 | 965.27 | 02-JAN-20:10 |
February | 0.141502E+10 | 1761.91 | 01-FEB-20:10 | 0.109956E+10 | 965.27 | 01-FEB-20:10 |
March | 0.155893E+10 | 1761.91 | 01-MAR-20:10 | 0.122063E+10 | 965.27 | 01-MAR-20:10 |
April | 0.146432E+10 | 1761.91 | 03-APR-19:10 | 0.117692E+10 | 965.27 | 03-APR-19:10 |
May | 0.148347E+10 | 1761.91 | 01-MAY-19:10 | 0.121917E+10 | 965.27 | 01-MAY-19:10 |
June | 0.143200E+10 | 1761.91 | 01-JUN-19:10 | 0.118076E+10 | 965.27 | 01-JUN-19:10 |
July | 0.147724E+10 | 1761.91 | 03-JUL-19:10 | 0.121533E+10 | 965.27 | 03-JUL-19:10 |
August | 0.150429E+10 | 1761.91 | 01-AUG-19:10 | 0.122063E+10 | 965.27 | 01-AUG-19:10 |
September | 0.149537E+10 | 1761.91 | 01-SEP-19:10 | 0.117692E+10 | 965.27 | 01-SEP-19:10 |
October | 0.156801E+10 | 1761.91 | 02-OCT-19:10 | 0.121771E+10 | 965.27 | 02-OCT-19:10 |
November | 0.153156E+10 | 1761.91 | 01-NOV-19:10 | 0.118021E+10 | 965.27 | 01-NOV-19:10 |
December | 0.158133E+10 | 1761.91 | 01-DEC-20:10 | 0.121533E+10 | 965.27 | 01-DEC-20:10 |
Annual Sum or Average | 0.180995E+11 | 0.143409E+11 | ||||
Minimum of Months | 0.141502E+10 | 1761.91 | 0.109956E+10 | 965.27 | ||
Maximum of Months | 0.158799E+10 | 1761.91 | 0.122063E+10 | 965.27 |
Report: ZoneElectricSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.122593E+11 | 12090.12 | 02-JAN-20:10 | 0.126520E+11 | 10029.21 | 02-JAN-20:10 |
February | 0.110475E+11 | 12090.12 | 01-FEB-20:10 | 0.114244E+11 | 10029.21 | 01-FEB-20:10 |
March | 0.122641E+11 | 12090.12 | 01-MAR-20:10 | 0.126824E+11 | 10029.21 | 01-MAR-20:10 |
April | 0.117648E+11 | 12090.12 | 03-APR-19:10 | 0.122282E+11 | 10029.21 | 03-APR-19:10 |
May | 0.121621E+11 | 12090.12 | 01-MAY-19:10 | 0.126672E+11 | 10029.21 | 01-MAY-19:10 |
June | 0.117757E+11 | 12090.12 | 01-JUN-19:10 | 0.122682E+11 | 10029.21 | 01-JUN-19:10 |
July | 0.121087E+11 | 12090.12 | 03-JUL-19:10 | 0.126273E+11 | 10029.21 | 03-JUL-19:10 |
August | 0.122021E+11 | 12090.12 | 01-AUG-19:10 | 0.126824E+11 | 10029.21 | 01-AUG-19:10 |
September | 0.118057E+11 | 12090.12 | 01-SEP-19:10 | 0.122282E+11 | 10029.21 | 01-SEP-19:10 |
October | 0.122411E+11 | 12090.12 | 02-OCT-19:10 | 0.126520E+11 | 10029.21 | 02-OCT-19:10 |
November | 0.118792E+11 | 12090.12 | 01-NOV-19:10 | 0.122624E+11 | 10029.21 | 01-NOV-19:10 |
December | 0.122238E+11 | 12090.12 | 01-DEC-20:10 | 0.126273E+11 | 10029.21 | 01-DEC-20:10 |
Annual Sum or Average | 0.143734E+12 | 0.149002E+12 | ||||
Minimum of Months | 0.110475E+11 | 12090.12 | 0.114244E+11 | 10029.21 | ||
Maximum of Months | 0.122641E+11 | 12090.12 | 0.126824E+11 | 10029.21 |
Report: ZoneElectricSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.120874E+09 | 142.14 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.109169E+09 | 142.14 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.120429E+09 | 142.14 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.117046E+09 | 142.14 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.120651E+09 | 142.14 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.116602E+09 | 142.14 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.121096E+09 | 142.14 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.120429E+09 | 142.14 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.117046E+09 | 142.14 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.120874E+09 | 142.14 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.116824E+09 | 142.14 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.121096E+09 | 142.14 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.142214E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.109169E+09 | 142.14 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.121096E+09 | 142.14 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.120859E+09 | 142.12 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.109156E+09 | 142.12 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.120415E+09 | 142.12 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.117032E+09 | 142.12 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.120637E+09 | 142.12 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.116588E+09 | 142.12 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.121082E+09 | 142.12 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.120415E+09 | 142.12 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.117032E+09 | 142.12 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.120859E+09 | 142.12 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.116810E+09 | 142.12 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.121082E+09 | 142.12 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.142197E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.109156E+09 | 142.12 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.121082E+09 | 142.12 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 75964402.59 | 89.33 | 01-JAN-19:10 | 0.255708E+09 | 232.19 | 01-JAN-08:09 |
February | 68608505.50 | 89.33 | 01-FEB-20:10 | 0.230956E+09 | 232.19 | 01-FEB-07:10 |
March | 75685198.85 | 89.33 | 01-MAR-20:10 | 0.255355E+09 | 232.19 | 01-MAR-07:10 |
April | 73558970.85 | 89.33 | 01-APR-18:10 | 0.247516E+09 | 232.19 | 01-APR-07:10 |
May | 75824800.72 | 89.33 | 01-MAY-19:10 | 0.255532E+09 | 232.19 | 01-MAY-06:10 |
June | 73279767.11 | 89.33 | 01-JUN-19:10 | 0.247163E+09 | 232.19 | 01-JUN-06:10 |
July | 76104004.46 | 89.33 | 01-JUL-18:10 | 0.255885E+09 | 232.19 | 01-JUL-07:10 |
August | 75685198.85 | 89.33 | 01-AUG-19:10 | 0.255355E+09 | 232.19 | 01-AUG-06:10 |
September | 73558970.85 | 89.33 | 01-SEP-19:10 | 0.247516E+09 | 232.19 | 01-SEP-06:10 |
October | 75964402.59 | 89.33 | 01-OCT-18:10 | 0.255708E+09 | 232.19 | 01-OCT-07:10 |
November | 73419368.98 | 89.33 | 01-NOV-19:10 | 0.247340E+09 | 232.19 | 01-NOV-06:10 |
December | 76104004.46 | 89.33 | 01-DEC-20:10 | 0.255885E+09 | 232.19 | 01-DEC-07:10 |
Annual Sum or Average | 0.893758E+09 | 0.300992E+10 | ||||
Minimum of Months | 68608505.50 | 89.33 | 0.230956E+09 | 232.19 | ||
Maximum of Months | 76104004.46 | 89.33 | 0.255885E+09 | 232.19 |
Report: ZoneElectricSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 75985174.92 | 89.35 | 01-JAN-19:10 | 0.255778E+09 | 232.26 | 01-JAN-08:09 |
February | 68627266.37 | 89.35 | 01-FEB-20:10 | 0.231020E+09 | 232.26 | 01-FEB-07:10 |
March | 75705894.83 | 89.35 | 01-MAR-20:10 | 0.255425E+09 | 232.26 | 01-MAR-07:10 |
April | 73579085.42 | 89.35 | 01-APR-18:10 | 0.247584E+09 | 232.26 | 01-APR-07:10 |
May | 75845534.87 | 89.35 | 01-MAY-19:10 | 0.255602E+09 | 232.26 | 01-MAY-06:10 |
June | 73299805.33 | 89.35 | 01-JUN-19:10 | 0.247231E+09 | 232.26 | 01-JUN-06:10 |
July | 76124814.96 | 89.35 | 01-JUL-18:10 | 0.255955E+09 | 232.26 | 01-JUL-07:10 |
August | 75705894.83 | 89.35 | 01-AUG-19:10 | 0.255425E+09 | 232.26 | 01-AUG-06:10 |
September | 73579085.42 | 89.35 | 01-SEP-19:10 | 0.247584E+09 | 232.26 | 01-SEP-06:10 |
October | 75985174.92 | 89.35 | 01-OCT-18:10 | 0.255778E+09 | 232.26 | 01-OCT-07:10 |
November | 73439445.37 | 89.35 | 01-NOV-19:10 | 0.247408E+09 | 232.26 | 01-NOV-06:10 |
December | 76124814.96 | 89.35 | 01-DEC-20:10 | 0.255955E+09 | 232.26 | 01-DEC-07:10 |
Annual Sum or Average | 0.894002E+09 | 0.301074E+10 | ||||
Minimum of Months | 68627266.37 | 89.35 | 0.231020E+09 | 232.26 | ||
Maximum of Months | 76124814.96 | 89.35 | 0.255955E+09 | 232.26 |
Report: ZoneElectricSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.120874E+09 | 142.14 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.109169E+09 | 142.14 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.120429E+09 | 142.14 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.117046E+09 | 142.14 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.120651E+09 | 142.14 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.116602E+09 | 142.14 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.121096E+09 | 142.14 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.120429E+09 | 142.14 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.117046E+09 | 142.14 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.120874E+09 | 142.14 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.116824E+09 | 142.14 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.121096E+09 | 142.14 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.142214E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.109169E+09 | 142.14 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.121096E+09 | 142.14 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.120859E+09 | 142.12 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.109156E+09 | 142.12 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.120415E+09 | 142.12 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.117032E+09 | 142.12 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.120637E+09 | 142.12 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.116588E+09 | 142.12 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.121082E+09 | 142.12 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.120415E+09 | 142.12 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.117032E+09 | 142.12 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.120859E+09 | 142.12 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.116810E+09 | 142.12 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.121082E+09 | 142.12 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.142197E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.109156E+09 | 142.12 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.121082E+09 | 142.12 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.232638E+10 | 2240.79 | 02-JAN-20:10 | 0.00 | 0.00 |
February | 0.210051E+10 | 2240.79 | 01-FEB-20:10 | 0.00 | 0.00 |
March | 0.233445E+10 | 2240.79 | 01-MAR-20:10 | 0.00 | 0.00 |
April | 0.224751E+10 | 2240.79 | 03-APR-19:10 | 0.00 | 0.00 |
May | 0.233042E+10 | 2240.79 | 01-MAY-19:10 | 0.00 | 0.00 |
June | 0.225781E+10 | 2240.79 | 01-JUN-19:10 | 0.00 | 0.00 |
July | 0.232011E+10 | 2240.79 | 03-JUL-19:10 | 0.00 | 0.00 |
August | 0.233445E+10 | 2240.79 | 01-AUG-19:10 | 0.00 | 0.00 |
September | 0.224751E+10 | 2240.79 | 01-SEP-19:10 | 0.00 | 0.00 |
October | 0.232638E+10 | 2240.79 | 02-OCT-19:10 | 0.00 | 0.00 |
November | 0.225602E+10 | 2240.79 | 01-NOV-19:10 | 0.00 | 0.00 |
December | 0.232011E+10 | 2240.79 | 01-DEC-20:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.274017E+11 | ||||
Minimum of Months | 0.210051E+10 | 2240.79 | 0.00 | 0.00 | |
Maximum of Months | 0.233445E+10 | 2240.79 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.120874E+09 | 142.14 | 01-JAN-19:10 | 0.261068E+09 | 237.06 | 01-JAN-08:09 |
February | 0.109169E+09 | 142.14 | 01-FEB-20:10 | 0.235798E+09 | 237.06 | 01-FEB-07:10 |
March | 0.120429E+09 | 142.14 | 01-MAR-20:10 | 0.260708E+09 | 237.06 | 01-MAR-07:10 |
April | 0.117046E+09 | 142.14 | 01-APR-18:10 | 0.252705E+09 | 237.06 | 01-APR-07:10 |
May | 0.120651E+09 | 142.14 | 01-MAY-19:10 | 0.260888E+09 | 237.06 | 01-MAY-06:10 |
June | 0.116602E+09 | 142.14 | 01-JUN-19:10 | 0.252344E+09 | 237.06 | 01-JUN-06:10 |
July | 0.121096E+09 | 142.14 | 01-JUL-18:10 | 0.261248E+09 | 237.06 | 01-JUL-07:10 |
August | 0.120429E+09 | 142.14 | 01-AUG-19:10 | 0.260708E+09 | 237.06 | 01-AUG-06:10 |
September | 0.117046E+09 | 142.14 | 01-SEP-19:10 | 0.252705E+09 | 237.06 | 01-SEP-06:10 |
October | 0.120874E+09 | 142.14 | 01-OCT-18:10 | 0.261068E+09 | 237.06 | 01-OCT-07:10 |
November | 0.116824E+09 | 142.14 | 01-NOV-19:10 | 0.252524E+09 | 237.06 | 01-NOV-06:10 |
December | 0.121096E+09 | 142.14 | 01-DEC-20:10 | 0.261248E+09 | 237.06 | 01-DEC-07:10 |
Annual Sum or Average | 0.142214E+10 | 0.307301E+10 | ||||
Minimum of Months | 0.109169E+09 | 142.14 | 0.235798E+09 | 237.06 | ||
Maximum of Months | 0.121096E+09 | 142.14 | 0.261248E+09 | 237.06 |
Report: ZoneElectricSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.120859E+09 | 142.12 | 01-JAN-19:10 | 0.261038E+09 | 237.03 | 01-JAN-08:09 |
February | 0.109156E+09 | 142.12 | 01-FEB-20:10 | 0.235770E+09 | 237.03 | 01-FEB-07:10 |
March | 0.120415E+09 | 142.12 | 01-MAR-20:10 | 0.260677E+09 | 237.03 | 01-MAR-07:10 |
April | 0.117032E+09 | 142.12 | 01-APR-18:10 | 0.252675E+09 | 237.03 | 01-APR-07:10 |
May | 0.120637E+09 | 142.12 | 01-MAY-19:10 | 0.260857E+09 | 237.03 | 01-MAY-06:10 |
June | 0.116588E+09 | 142.12 | 01-JUN-19:10 | 0.252315E+09 | 237.03 | 01-JUN-06:10 |
July | 0.121082E+09 | 142.12 | 01-JUL-18:10 | 0.261218E+09 | 237.03 | 01-JUL-07:10 |
August | 0.120415E+09 | 142.12 | 01-AUG-19:10 | 0.260677E+09 | 237.03 | 01-AUG-06:10 |
September | 0.117032E+09 | 142.12 | 01-SEP-19:10 | 0.252675E+09 | 237.03 | 01-SEP-06:10 |
October | 0.120859E+09 | 142.12 | 01-OCT-18:10 | 0.261038E+09 | 237.03 | 01-OCT-07:10 |
November | 0.116810E+09 | 142.12 | 01-NOV-19:10 | 0.252495E+09 | 237.03 | 01-NOV-06:10 |
December | 0.121082E+09 | 142.12 | 01-DEC-20:10 | 0.261218E+09 | 237.03 | 01-DEC-07:10 |
Annual Sum or Average | 0.142197E+10 | 0.307265E+10 | ||||
Minimum of Months | 0.109156E+09 | 142.12 | 0.235770E+09 | 237.03 | ||
Maximum of Months | 0.121082E+09 | 142.12 | 0.261218E+09 | 237.03 |
Report: ZoneElectricSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 75985174.92 | 89.35 | 01-JAN-19:10 | 0.255778E+09 | 232.26 | 01-JAN-08:09 |
February | 68627266.37 | 89.35 | 01-FEB-20:10 | 0.231020E+09 | 232.26 | 01-FEB-07:10 |
March | 75705894.83 | 89.35 | 01-MAR-20:10 | 0.255425E+09 | 232.26 | 01-MAR-07:10 |
April | 73579085.42 | 89.35 | 01-APR-18:10 | 0.247584E+09 | 232.26 | 01-APR-07:10 |
May | 75845534.87 | 89.35 | 01-MAY-19:10 | 0.255602E+09 | 232.26 | 01-MAY-06:10 |
June | 73299805.33 | 89.35 | 01-JUN-19:10 | 0.247231E+09 | 232.26 | 01-JUN-06:10 |
July | 76124814.96 | 89.35 | 01-JUL-18:10 | 0.255955E+09 | 232.26 | 01-JUL-07:10 |
August | 75705894.83 | 89.35 | 01-AUG-19:10 | 0.255425E+09 | 232.26 | 01-AUG-06:10 |
September | 73579085.42 | 89.35 | 01-SEP-19:10 | 0.247584E+09 | 232.26 | 01-SEP-06:10 |
October | 75985174.92 | 89.35 | 01-OCT-18:10 | 0.255778E+09 | 232.26 | 01-OCT-07:10 |
November | 73439445.37 | 89.35 | 01-NOV-19:10 | 0.247408E+09 | 232.26 | 01-NOV-06:10 |
December | 76124814.96 | 89.35 | 01-DEC-20:10 | 0.255955E+09 | 232.26 | 01-DEC-07:10 |
Annual Sum or Average | 0.894002E+09 | 0.301074E+10 | ||||
Minimum of Months | 68627266.37 | 89.35 | 0.231020E+09 | 232.26 | ||
Maximum of Months | 76124814.96 | 89.35 | 0.255955E+09 | 232.26 |
Report: ZoneElectricSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.302136E+10 | 3094.06 | 02-JAN-20:10 | 0.149358E+11 | 6747.90 | 01-JAN-07:10 |
February | 0.270213E+10 | 3094.06 | 01-FEB-20:10 | 0.134904E+11 | 6747.90 | 01-FEB-07:10 |
March | 0.298494E+10 | 3094.06 | 01-MAR-20:10 | 0.149358E+11 | 6747.90 | 01-MAR-07:10 |
April | 0.283148E+10 | 3094.06 | 03-APR-19:10 | 0.144540E+11 | 6747.90 | 01-APR-06:10 |
May | 0.289703E+10 | 3094.06 | 01-MAY-19:10 | 0.149358E+11 | 6747.90 | 01-MAY-06:10 |
June | 0.279543E+10 | 3094.06 | 01-JUN-19:10 | 0.144540E+11 | 6747.90 | 01-JUN-06:10 |
July | 0.287855E+10 | 3094.06 | 03-JUL-19:10 | 0.149358E+11 | 6747.90 | 01-JUL-06:10 |
August | 0.292159E+10 | 3094.06 | 01-AUG-19:10 | 0.149358E+11 | 6747.90 | 01-AUG-06:10 |
September | 0.286641E+10 | 3094.06 | 01-SEP-19:10 | 0.144540E+11 | 6747.90 | 01-SEP-06:10 |
October | 0.300388E+10 | 3094.06 | 02-OCT-19:10 | 0.149358E+11 | 6747.90 | 01-OCT-06:10 |
November | 0.291991E+10 | 3094.06 | 01-NOV-19:10 | 0.144540E+11 | 6747.90 | 01-NOV-06:10 |
December | 0.301544E+10 | 3094.06 | 01-DEC-20:10 | 0.149358E+11 | 6747.90 | 01-DEC-07:10 |
Annual Sum or Average | 0.348381E+11 | 0.175857E+12 | ||||
Minimum of Months | 0.270213E+10 | 3094.06 | 0.134904E+11 | 6747.90 | ||
Maximum of Months | 0.302136E+10 | 3094.06 | 0.149358E+11 | 6747.90 |
Report: ZoneElectricSummaryMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.302136E+10 | 3094.06 | 02-JAN-20:10 | 0.149358E+11 | 6747.90 | 01-JAN-07:10 |
February | 0.270213E+10 | 3094.06 | 01-FEB-20:10 | 0.134904E+11 | 6747.90 | 01-FEB-07:10 |
March | 0.298494E+10 | 3094.06 | 01-MAR-20:10 | 0.149358E+11 | 6747.90 | 01-MAR-07:10 |
April | 0.283148E+10 | 3094.06 | 03-APR-19:10 | 0.144540E+11 | 6747.90 | 01-APR-06:10 |
May | 0.289703E+10 | 3094.06 | 01-MAY-19:10 | 0.149358E+11 | 6747.90 | 01-MAY-06:10 |
June | 0.279543E+10 | 3094.06 | 01-JUN-19:10 | 0.144540E+11 | 6747.90 | 01-JUN-06:10 |
July | 0.287855E+10 | 3094.06 | 03-JUL-19:10 | 0.149358E+11 | 6747.90 | 01-JUL-06:10 |
August | 0.292159E+10 | 3094.06 | 01-AUG-19:10 | 0.149358E+11 | 6747.90 | 01-AUG-06:10 |
September | 0.286641E+10 | 3094.06 | 01-SEP-19:10 | 0.144540E+11 | 6747.90 | 01-SEP-06:10 |
October | 0.300388E+10 | 3094.06 | 02-OCT-19:10 | 0.149358E+11 | 6747.90 | 01-OCT-06:10 |
November | 0.291991E+10 | 3094.06 | 01-NOV-19:10 | 0.144540E+11 | 6747.90 | 01-NOV-06:10 |
December | 0.301544E+10 | 3094.06 | 01-DEC-20:10 | 0.149358E+11 | 6747.90 | 01-DEC-07:10 |
Annual Sum or Average | 0.348381E+11 | 0.175857E+12 | ||||
Minimum of Months | 0.270213E+10 | 3094.06 | 0.134904E+11 | 6747.90 | ||
Maximum of Months | 0.302136E+10 | 3094.06 | 0.149358E+11 | 6747.90 |
Report: ZoneElectricSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.113146E+10 | 1089.83 | 02-JAN-20:10 | 0.368383E+11 | 16487.34 | 01-JAN-07:10 |
February | 0.102161E+10 | 1089.83 | 01-FEB-20:10 | 0.332733E+11 | 16487.34 | 01-FEB-07:10 |
March | 0.113539E+10 | 1089.83 | 01-MAR-20:10 | 0.368383E+11 | 16487.34 | 01-MAR-07:10 |
April | 0.109310E+10 | 1089.83 | 03-APR-19:10 | 0.356500E+11 | 16487.34 | 01-APR-06:10 |
May | 0.113343E+10 | 1089.83 | 01-MAY-19:10 | 0.368383E+11 | 16487.34 | 01-MAY-06:10 |
June | 0.109811E+10 | 1089.83 | 01-JUN-19:10 | 0.356500E+11 | 16487.34 | 01-JUN-06:10 |
July | 0.112841E+10 | 1089.83 | 03-JUL-19:10 | 0.368383E+11 | 16487.34 | 01-JUL-06:10 |
August | 0.113539E+10 | 1089.83 | 01-AUG-19:10 | 0.368383E+11 | 16487.34 | 01-AUG-06:10 |
September | 0.109310E+10 | 1089.83 | 01-SEP-19:10 | 0.356500E+11 | 16487.34 | 01-SEP-06:10 |
October | 0.113146E+10 | 1089.83 | 02-OCT-19:10 | 0.368383E+11 | 16487.34 | 01-OCT-06:10 |
November | 0.109724E+10 | 1089.83 | 01-NOV-19:10 | 0.356500E+11 | 16487.34 | 01-NOV-06:10 |
December | 0.112841E+10 | 1089.83 | 01-DEC-20:10 | 0.368383E+11 | 16487.34 | 01-DEC-07:10 |
Annual Sum or Average | 0.133271E+11 | 0.433742E+12 | ||||
Minimum of Months | 0.102161E+10 | 1089.83 | 0.332733E+11 | 16487.34 | ||
Maximum of Months | 0.113539E+10 | 1089.83 | 0.368383E+11 | 16487.34 |
Report: ZoneElectricSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.246212E+10 | 2371.52 | 02-JAN-20:10 | 0.00 | 0.00 |
February | 0.222307E+10 | 2371.52 | 01-FEB-20:10 | 0.00 | 0.00 |
March | 0.247065E+10 | 2371.52 | 01-MAR-20:10 | 0.00 | 0.00 |
April | 0.237864E+10 | 2371.52 | 03-APR-19:10 | 0.00 | 0.00 |
May | 0.246639E+10 | 2371.52 | 01-MAY-19:10 | 0.00 | 0.00 |
June | 0.238955E+10 | 2371.52 | 01-JUN-19:10 | 0.00 | 0.00 |
July | 0.245548E+10 | 2371.52 | 03-JUL-19:10 | 0.00 | 0.00 |
August | 0.247065E+10 | 2371.52 | 01-AUG-19:10 | 0.00 | 0.00 |
September | 0.237864E+10 | 2371.52 | 01-SEP-19:10 | 0.00 | 0.00 |
October | 0.246212E+10 | 2371.52 | 02-OCT-19:10 | 0.00 | 0.00 |
November | 0.238765E+10 | 2371.52 | 01-NOV-19:10 | 0.00 | 0.00 |
December | 0.245548E+10 | 2371.52 | 01-DEC-20:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.290004E+11 | ||||
Minimum of Months | 0.222307E+10 | 2371.52 | 0.00 | 0.00 | |
Maximum of Months | 0.247065E+10 | 2371.52 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.195762E+11 | 0.144724E+11 | 0.127587E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.176991E+11 | 0.130672E+11 | 0.115208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.196590E+11 | 0.145225E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.189781E+11 | 0.139817E+11 | 0.123314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.196176E+11 | 0.144975E+11 | 0.127741E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.190195E+11 | 0.140458E+11 | 0.123716E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.195762E+11 | 0.144333E+11 | 0.127338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.196590E+11 | 0.145225E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.189781E+11 | 0.139817E+11 | 0.123314E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.195762E+11 | 0.144724E+11 | 0.127587E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.189367E+11 | 0.140346E+11 | 0.123659E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.195762E+11 | 0.144333E+11 | 0.127338E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.230852E+12 | 0.170465E+12 | 0.150259E+12 | ||||||
Minimum of Months | 0.176991E+11 | 0.130672E+11 | 0.115208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.196590E+11 | 0.145225E+11 | 0.127894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.199054E+10 | 0.764969E+09 | 0.864900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3536138.80 | 0.548008E+09 |
February | 0.179968E+10 | 0.690697E+09 | 0.780982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 287254.05 | 0.472693E+09 |
March | 0.199896E+10 | 0.767621E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 248249.01 | 0.549203E+09 |
April | 0.192973E+10 | 0.739033E+09 | 0.835931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6941958.60 | 0.367807E+09 |
May | 0.199475E+10 | 0.766295E+09 | 0.865939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2869488.45 | 0.350312E+09 |
June | 0.193394E+10 | 0.742422E+09 | 0.838659E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 15864147.24 | 0.223065E+09 |
July | 0.199054E+10 | 0.762906E+09 | 0.863211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 40671358.42 | 0.148829E+09 |
August | 0.199896E+10 | 0.767621E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41274303.88 | 0.144413E+09 |
September | 0.192973E+10 | 0.739033E+09 | 0.835931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 21887890.27 | 0.205823E+09 |
October | 0.199054E+10 | 0.764969E+09 | 0.864900E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 33189827.63 | 0.229511E+09 |
November | 0.192552E+10 | 0.741833E+09 | 0.838269E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1358242.56 | 0.460376E+09 |
December | 0.199054E+10 | 0.762906E+09 | 0.863211E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 989206.74 | 0.529238E+09 |
Annual Sum or Average | 0.234734E+11 | 0.901031E+10 | 0.101859E+11 | 0.169118E+09 | 0.422928E+10 | ||||
Minimum of Months | 0.179968E+10 | 0.690697E+09 | 0.780982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 248249.01 | 0.144413E+09 |
Maximum of Months | 0.199896E+10 | 0.767621E+09 | 0.866978E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41274303.88 | 0.549203E+09 |
Report: SpaceGainsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.230505E+10 | 0.885837E+09 | 0.100156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1570781.07 | 0.118861E+09 |
February | 0.208403E+10 | 0.799830E+09 | 0.904380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 244647.33 | 0.105989E+09 |
March | 0.231480E+10 | 0.888909E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 446837.04 | 0.123849E+09 |
April | 0.223463E+10 | 0.855803E+09 | 0.968011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1762457.17 | 88410306.32 |
May | 0.230993E+10 | 0.887373E+09 | 0.100276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 619713.19 | 85338840.00 |
June | 0.223950E+10 | 0.859728E+09 | 0.971170E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2944533.43 | 57284012.79 |
July | 0.230505E+10 | 0.883448E+09 | 0.999601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7880289.40 | 41146688.32 |
August | 0.231480E+10 | 0.888909E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8960137.74 | 39889571.75 |
September | 0.223463E+10 | 0.855803E+09 | 0.968011E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5663674.19 | 51501599.23 |
October | 0.230505E+10 | 0.885837E+09 | 0.100156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9641941.94 | 55186779.68 |
November | 0.222975E+10 | 0.859045E+09 | 0.970719E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1043552.96 | 0.103391E+09 |
December | 0.230505E+10 | 0.883448E+09 | 0.999601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1367483.76 | 0.115495E+09 |
Annual Sum or Average | 0.271823E+11 | 0.104340E+11 | 0.117953E+11 | 42146049.24 | 0.986343E+09 | ||||
Minimum of Months | 0.208403E+10 | 0.799830E+09 | 0.904380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 244647.33 | 39889571.75 |
Maximum of Months | 0.231480E+10 | 0.888909E+09 | 0.100396E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9641941.94 | 0.123849E+09 |
Report: SpaceGainsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.154405E+10 | 0.423840E+09 | 0.576866E+10 | 0.501157E+11 | 0.00 | 0.00 | 0.00 | 5670342.37 | 0.370068E+09 |
February | 0.139600E+10 | 0.382689E+09 | 0.520895E+10 | 0.452532E+11 | 0.00 | 0.00 | 0.00 | 1041834.80 | 0.329873E+09 |
March | 0.155059E+10 | 0.425309E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 1767344.72 | 0.391392E+09 |
April | 0.149688E+10 | 0.409470E+09 | 0.557545E+10 | 0.484372E+11 | 0.00 | 0.00 | 0.00 | 6121414.06 | 0.276003E+09 |
May | 0.154732E+10 | 0.424575E+09 | 0.577559E+10 | 0.501759E+11 | 0.00 | 0.00 | 0.00 | 2181892.96 | 0.268808E+09 |
June | 0.150015E+10 | 0.411347E+09 | 0.559364E+10 | 0.485952E+11 | 0.00 | 0.00 | 0.00 | 10105809.32 | 0.179181E+09 |
July | 0.154405E+10 | 0.422697E+09 | 0.575740E+10 | 0.500179E+11 | 0.00 | 0.00 | 0.00 | 26800251.80 | 0.126801E+09 |
August | 0.155059E+10 | 0.425309E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 31291707.96 | 0.122311E+09 |
September | 0.149688E+10 | 0.409470E+09 | 0.557545E+10 | 0.484372E+11 | 0.00 | 0.00 | 0.00 | 20482503.32 | 0.157016E+09 |
October | 0.154405E+10 | 0.423840E+09 | 0.576866E+10 | 0.501157E+11 | 0.00 | 0.00 | 0.00 | 34865157.55 | 0.166010E+09 |
November | 0.149361E+10 | 0.411021E+09 | 0.559104E+10 | 0.485726E+11 | 0.00 | 0.00 | 0.00 | 4523412.22 | 0.314740E+09 |
December | 0.154405E+10 | 0.422697E+09 | 0.575740E+10 | 0.500179E+11 | 0.00 | 0.00 | 0.00 | 5891826.09 | 0.356366E+09 |
Annual Sum or Average | 0.182082E+11 | 0.499226E+10 | 0.679373E+11 | 0.590211E+12 | 0.150743E+09 | 0.305857E+10 | |||
Minimum of Months | 0.139600E+10 | 0.382689E+09 | 0.520895E+10 | 0.452532E+11 | 0.00 | 0.00 | 0.00 | 1041834.80 | 0.122311E+09 |
Maximum of Months | 0.155059E+10 | 0.425309E+09 | 0.578252E+10 | 0.502361E+11 | 0.00 | 0.00 | 0.00 | 34865157.55 | 0.391392E+09 |
Report: SpaceGainsMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.261570E+11 | 0.158799E+10 | 0.121771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8985632.91 | 0.151939E+10 |
February | 0.236489E+11 | 0.141502E+10 | 0.109956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 803618.41 | 0.132734E+10 |
March | 0.262677E+11 | 0.155893E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 660781.01 | 0.151638E+10 |
April | 0.253579E+11 | 0.146432E+10 | 0.117692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16754289.67 | 0.107131E+10 |
May | 0.262123E+11 | 0.148347E+10 | 0.121917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 7514405.00 | 0.102230E+10 |
June | 0.254132E+11 | 0.143200E+10 | 0.118076E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37803068.98 | 0.693458E+09 |
July | 0.261570E+11 | 0.147724E+10 | 0.121533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 98139690.72 | 0.502376E+09 |
August | 0.262677E+11 | 0.150429E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103546E+09 | 0.494699E+09 |
September | 0.253579E+11 | 0.149537E+10 | 0.117692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 52528575.29 | 0.648023E+09 |
October | 0.261570E+11 | 0.156801E+10 | 0.121771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 84515257.17 | 0.714433E+09 |
November | 0.253025E+11 | 0.153156E+10 | 0.118021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3513958.98 | 0.131791E+10 |
December | 0.261570E+11 | 0.158133E+10 | 0.121533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2824869.66 | 0.148046E+10 |
Annual Sum or Average | 0.308456E+12 | 0.180995E+11 | 0.143409E+11 | 0.417590E+09 | 0.123081E+11 | ||||
Minimum of Months | 0.236489E+11 | 0.141502E+10 | 0.109956E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 660781.01 | 0.494699E+09 |
Maximum of Months | 0.262677E+11 | 0.158799E+10 | 0.122063E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103546E+09 | 0.151939E+10 |
Report: SpaceGainsMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.776503E+11 | 0.122593E+11 | 0.126520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31309739.46 | 0.300036E+10 |
February | 0.702046E+11 | 0.110475E+11 | 0.114244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4349625.33 | 0.267216E+10 |
March | 0.779788E+11 | 0.122641E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 7908837.29 | 0.309892E+10 |
April | 0.752779E+11 | 0.117648E+11 | 0.122282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 38938854.63 | 0.221853E+10 |
May | 0.778146E+11 | 0.121621E+11 | 0.126672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 14561618.25 | 0.214657E+10 |
June | 0.754422E+11 | 0.117757E+11 | 0.122682E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 69930782.48 | 0.146114E+10 |
July | 0.776503E+11 | 0.121087E+11 | 0.126273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.186856E+09 | 0.106154E+10 |
August | 0.779788E+11 | 0.122021E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210333E+09 | 0.103148E+10 |
September | 0.752779E+11 | 0.118057E+11 | 0.122282E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.125699E+09 | 0.132147E+10 |
October | 0.776503E+11 | 0.122411E+11 | 0.126520E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214034E+09 | 0.142706E+10 |
November | 0.751137E+11 | 0.118792E+11 | 0.122624E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 18998730.73 | 0.261690E+10 |
December | 0.776503E+11 | 0.122238E+11 | 0.126273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 23645250.68 | 0.291971E+10 |
Annual Sum or Average | 0.915690E+12 | 0.143734E+12 | 0.149002E+12 | 0.946566E+09 | 0.249758E+11 | ||||
Minimum of Months | 0.702046E+11 | 0.110475E+11 | 0.114244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 4349625.33 | 0.103148E+10 |
Maximum of Months | 0.779788E+11 | 0.122641E+11 | 0.126824E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.214034E+09 | 0.309892E+10 |
Report: SpaceGainsMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.120874E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1244968.95 | 0.157274E+09 |
February | 0.273974E+09 | 0.109169E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 200935.77 | 0.137176E+09 |
March | 0.303685E+09 | 0.120429E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 204779.47 | 0.163509E+09 |
April | 0.293479E+09 | 0.117046E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1216088.95 | 0.113003E+09 |
May | 0.303504E+09 | 0.120651E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 137629.06 | 0.109829E+09 |
June | 0.293842E+09 | 0.116602E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1822818.99 | 70710164.28 |
July | 0.303141E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6563944.73 | 46774764.15 |
August | 0.303685E+09 | 0.120429E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 7557707.75 | 43949000.77 |
September | 0.293479E+09 | 0.117046E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6611868.33 | 62611783.64 |
October | 0.303322E+09 | 0.120874E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11500307.19 | 64332212.46 |
November | 0.293661E+09 | 0.116824E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 883520.76 | 0.131382E+09 |
December | 0.303141E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 981020.79 | 0.150140E+09 |
Annual Sum or Average | 0.357224E+10 | 0.142214E+10 | 0.307301E+10 | 38925590.74 | 0.125069E+10 | ||||
Minimum of Months | 0.273974E+09 | 0.109169E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 137629.06 | 43949000.77 |
Maximum of Months | 0.303685E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11500307.19 | 0.163509E+09 |
Report: SpaceGainsMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.120859E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1816383.33 | 0.152410E+09 |
February | 0.273974E+09 | 0.109156E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 340533.54 | 0.134074E+09 |
March | 0.303685E+09 | 0.120415E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 409766.46 | 0.161116E+09 |
April | 0.293479E+09 | 0.117032E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1543939.27 | 0.111769E+09 |
May | 0.303504E+09 | 0.120637E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 179475.04 | 0.109532E+09 |
June | 0.293842E+09 | 0.116588E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1829640.87 | 70693447.73 |
July | 0.303141E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6676326.14 | 46751315.38 |
August | 0.303685E+09 | 0.120415E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 8168218.83 | 43738103.46 |
September | 0.293479E+09 | 0.117032E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6938665.04 | 61119109.92 |
October | 0.303322E+09 | 0.120859E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12594516.48 | 62899394.65 |
November | 0.293661E+09 | 0.116810E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1393260.15 | 0.127806E+09 |
December | 0.303141E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1877686.36 | 0.145635E+09 |
Annual Sum or Average | 0.357224E+10 | 0.142197E+10 | 0.307265E+10 | 43768411.49 | 0.122754E+10 | ||||
Minimum of Months | 0.273974E+09 | 0.109156E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 179475.04 | 43738103.46 |
Maximum of Months | 0.303685E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12594516.48 | 0.161116E+09 |
Report: SpaceGainsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 75964402.59 | 0.255708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 162933.92 | 51062319.01 |
February | 0.00 | 68608505.50 | 0.230956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20862.64 | 44483394.09 |
March | 0.00 | 75685198.85 | 0.255355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14490.46 | 51070090.43 |
April | 0.00 | 73558970.85 | 0.247516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 208484.89 | 37054818.35 |
May | 0.00 | 75824800.72 | 0.255532E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 22184.60 | 33357242.62 |
June | 0.00 | 73279767.11 | 0.247163E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 317359.67 | 22178365.13 |
July | 0.00 | 76104004.46 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 979608.71 | 17954205.87 |
August | 0.00 | 75685198.85 | 0.255355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 983616.89 | 18735438.51 |
September | 0.00 | 73558970.85 | 0.247516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1315244.09 | 24486139.77 |
October | 0.00 | 75964402.59 | 0.255708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2516600.54 | 25327140.94 |
November | 0.00 | 73419368.98 | 0.247340E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 156639.06 | 44387029.46 |
December | 0.00 | 76104004.46 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 137832.70 | 49645925.22 |
Annual Sum or Average | 0.00 | 0.893758E+09 | 0.300992E+10 | 6835858.18 | 0.419742E+09 | ||||
Minimum of Months | 0.00 | 68608505.50 | 0.230956E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14490.46 | 17954205.87 |
Maximum of Months | 0.00 | 76104004.46 | 0.255885E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2516600.54 | 51070090.43 |
Report: SpaceGainsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 75985174.92 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 626259.44 | 42481998.07 |
February | 0.273974E+09 | 68627266.37 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 119792.81 | 37406022.09 |
March | 0.303685E+09 | 75705894.83 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 173220.65 | 45001034.72 |
April | 0.293479E+09 | 73579085.42 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 583959.92 | 30684257.67 |
May | 0.303504E+09 | 75845534.87 | 0.255602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 131372.31 | 29957041.56 |
June | 0.293842E+09 | 73299805.33 | 0.247231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 760306.75 | 19108413.04 |
July | 0.303141E+09 | 76124814.96 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2450913.95 | 12560981.19 |
August | 0.303685E+09 | 75705894.83 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3020204.61 | 11847909.35 |
September | 0.293479E+09 | 73579085.42 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2194905.27 | 16415415.80 |
October | 0.303322E+09 | 75985174.92 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3954417.83 | 17277277.87 |
November | 0.293661E+09 | 73439445.37 | 0.247408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 507147.50 | 35277510.57 |
December | 0.303141E+09 | 76124814.96 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 681713.75 | 40497563.23 |
Annual Sum or Average | 0.357224E+10 | 0.894002E+09 | 0.301074E+10 | 15204214.79 | 0.338515E+09 | ||||
Minimum of Months | 0.273974E+09 | 68627266.37 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 119792.81 | 11847909.35 |
Maximum of Months | 0.303685E+09 | 76124814.96 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3954417.83 | 45001034.72 |
Report: SpaceGainsMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.120874E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1186927.89 | 0.157999E+09 |
February | 0.273974E+09 | 0.109169E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 193438.30 | 0.137549E+09 |
March | 0.303685E+09 | 0.120429E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 182013.61 | 0.164355E+09 |
April | 0.293479E+09 | 0.117046E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 966823.29 | 0.113987E+09 |
May | 0.303504E+09 | 0.120651E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 92148.26 | 0.110278E+09 |
June | 0.293842E+09 | 0.116602E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1314334.05 | 70742523.91 |
July | 0.303141E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5775629.23 | 47299042.84 |
August | 0.303685E+09 | 0.120429E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6685858.69 | 44469714.81 |
September | 0.293479E+09 | 0.117046E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6488991.91 | 62775851.80 |
October | 0.303322E+09 | 0.120874E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11368956.69 | 64720887.18 |
November | 0.293661E+09 | 0.116824E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 861306.16 | 0.131647E+09 |
December | 0.303141E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 949973.14 | 0.150625E+09 |
Annual Sum or Average | 0.357224E+10 | 0.142214E+10 | 0.307301E+10 | 36066401.23 | 0.125645E+10 | ||||
Minimum of Months | 0.273974E+09 | 0.109169E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 92148.26 | 44469714.81 |
Maximum of Months | 0.303685E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11368956.69 | 0.164355E+09 |
Report: SpaceGainsMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.120859E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1898719.90 | 0.152373E+09 |
February | 0.273974E+09 | 0.109156E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 325102.01 | 0.133796E+09 |
March | 0.303685E+09 | 0.120415E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 300072.40 | 0.161599E+09 |
April | 0.293479E+09 | 0.117032E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1150544.04 | 0.112378E+09 |
May | 0.303504E+09 | 0.120637E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 111771.76 | 0.109908E+09 |
June | 0.293842E+09 | 0.116588E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1322942.04 | 70722012.19 |
July | 0.303141E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5817615.89 | 47252448.87 |
August | 0.303685E+09 | 0.120415E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6978739.65 | 44053157.78 |
September | 0.293479E+09 | 0.117032E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6635415.63 | 60659367.94 |
October | 0.303322E+09 | 0.120859E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12253157.60 | 62868254.06 |
November | 0.293661E+09 | 0.116810E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1471819.47 | 0.126780E+09 |
December | 0.303141E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1916987.71 | 0.145040E+09 |
Annual Sum or Average | 0.357224E+10 | 0.142197E+10 | 0.307265E+10 | 40182888.10 | 0.122743E+10 | ||||
Minimum of Months | 0.273974E+09 | 0.109156E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 111771.76 | 44053157.78 |
Maximum of Months | 0.303685E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12253157.60 | 0.161599E+09 |
Report: SpaceGainsMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.120874E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1146834.30 | 0.158057E+09 |
February | 0.273974E+09 | 0.109169E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 192546.85 | 0.137890E+09 |
March | 0.303685E+09 | 0.120429E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 179093.32 | 0.164544E+09 |
April | 0.293479E+09 | 0.117046E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1036439.43 | 0.114702E+09 |
May | 0.303504E+09 | 0.120651E+09 | 0.260888E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83882.85 | 0.111837E+09 |
June | 0.293842E+09 | 0.116602E+09 | 0.252344E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1291274.82 | 72408811.18 |
July | 0.303141E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5677051.01 | 48178075.55 |
August | 0.303685E+09 | 0.120429E+09 | 0.260708E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6673361.03 | 45099735.78 |
September | 0.293479E+09 | 0.117046E+09 | 0.252705E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6395965.58 | 64128839.03 |
October | 0.303322E+09 | 0.120874E+09 | 0.261068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11192547.62 | 65439589.08 |
November | 0.293661E+09 | 0.116824E+09 | 0.252524E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 842754.15 | 0.132329E+09 |
December | 0.303141E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 928861.98 | 0.150934E+09 |
Annual Sum or Average | 0.357224E+10 | 0.142214E+10 | 0.307301E+10 | 35640612.93 | 0.126555E+10 | ||||
Minimum of Months | 0.273974E+09 | 0.109169E+09 | 0.235798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 83882.85 | 45099735.78 |
Maximum of Months | 0.303685E+09 | 0.121096E+09 | 0.261248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11192547.62 | 0.164544E+09 |
Report: SpaceGainsMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 0.120859E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1681104.38 | 0.152935E+09 |
February | 0.273974E+09 | 0.109156E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 321338.39 | 0.134677E+09 |
March | 0.303685E+09 | 0.120415E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 313930.82 | 0.162093E+09 |
April | 0.293479E+09 | 0.117032E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1237602.38 | 0.113474E+09 |
May | 0.303504E+09 | 0.120637E+09 | 0.260857E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 94237.78 | 0.111561E+09 |
June | 0.293842E+09 | 0.116588E+09 | 0.252315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1286371.56 | 72399578.51 |
July | 0.303141E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5712288.00 | 48160543.86 |
August | 0.303685E+09 | 0.120415E+09 | 0.260677E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6936693.39 | 44873089.63 |
September | 0.293479E+09 | 0.117032E+09 | 0.252675E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6586991.22 | 62855520.97 |
October | 0.303322E+09 | 0.120859E+09 | 0.261038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11995038.22 | 64031442.02 |
November | 0.293661E+09 | 0.116810E+09 | 0.252495E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1300204.24 | 0.128689E+09 |
December | 0.303141E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1769241.97 | 0.146158E+09 |
Annual Sum or Average | 0.357224E+10 | 0.142197E+10 | 0.307265E+10 | 39235042.34 | 0.124191E+10 | ||||
Minimum of Months | 0.273974E+09 | 0.109156E+09 | 0.235770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 94237.78 | 44873089.63 |
Maximum of Months | 0.303685E+09 | 0.121082E+09 | 0.261218E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11995038.22 | 0.162093E+09 |
Report: SpaceGainsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.303322E+09 | 75985174.92 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 502028.34 | 82524702.94 |
February | 0.273974E+09 | 68627266.37 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 90352.19 | 71958120.02 |
March | 0.303685E+09 | 75705894.83 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 80721.68 | 85411131.42 |
April | 0.293479E+09 | 73579085.42 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 486353.48 | 58909293.81 |
May | 0.303504E+09 | 75845534.87 | 0.255602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 43627.33 | 56488530.17 |
June | 0.293842E+09 | 73299805.33 | 0.247231E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 779929.85 | 36207740.91 |
July | 0.303141E+09 | 76124814.96 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3077663.79 | 24084516.31 |
August | 0.303685E+09 | 75705894.83 | 0.255425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3418670.63 | 22826804.79 |
September | 0.293479E+09 | 73579085.42 | 0.247584E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3247134.16 | 32863991.97 |
October | 0.303322E+09 | 75985174.92 | 0.255778E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5609586.76 | 33901010.59 |
November | 0.293661E+09 | 73439445.37 | 0.247408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 401965.57 | 69058977.19 |
December | 0.303141E+09 | 76124814.96 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 442359.49 | 78856387.51 |
Annual Sum or Average | 0.357224E+10 | 0.894002E+09 | 0.301074E+10 | 18180393.26 | 0.653091E+09 | ||||
Minimum of Months | 0.273974E+09 | 68627266.37 | 0.231020E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 43627.33 | 22826804.79 |
Maximum of Months | 0.303685E+09 | 76124814.96 | 0.255955E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5609586.76 | 85411131.42 |
Report: SpaceGainsMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.459349E+11 | 0.302136E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3583866.11 | 0.462655E+09 |
February | 0.415303E+11 | 0.270213E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 644248.06 | 0.417319E+09 |
March | 0.461292E+11 | 0.298494E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 538614.04 | 0.490868E+09 |
April | 0.445315E+11 | 0.283148E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2515194.58 | 0.362210E+09 |
May | 0.460320E+11 | 0.289703E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 430047.38 | 0.359439E+09 |
June | 0.446286E+11 | 0.279543E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2576024.31 | 0.255444E+09 |
July | 0.459349E+11 | 0.287855E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 12018985.52 | 0.193887E+09 |
August | 0.461292E+11 | 0.292159E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 14989053.41 | 0.185367E+09 |
September | 0.445315E+11 | 0.286641E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 12757443.52 | 0.227793E+09 |
October | 0.459349E+11 | 0.300388E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 26748824.06 | 0.235431E+09 |
November | 0.444343E+11 | 0.291991E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2755697.51 | 0.402118E+09 |
December | 0.459349E+11 | 0.301544E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 3617353.90 | 0.447018E+09 |
Annual Sum or Average | 0.541686E+12 | 0.348381E+11 | 0.175857E+12 | 83175352.43 | 0.403955E+10 | ||||
Minimum of Months | 0.415303E+11 | 0.270213E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 430047.38 | 0.185367E+09 |
Maximum of Months | 0.461292E+11 | 0.302136E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 26748824.06 | 0.490868E+09 |
Report: SpaceGainsMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.459349E+11 | 0.302136E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2966659.73 | 0.470486E+09 |
February | 0.415303E+11 | 0.270213E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 503887.92 | 0.424314E+09 |
March | 0.461292E+11 | 0.298494E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 369637.03 | 0.499105E+09 |
April | 0.445315E+11 | 0.283148E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1953656.67 | 0.368536E+09 |
May | 0.460320E+11 | 0.289703E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 292897.57 | 0.366438E+09 |
June | 0.446286E+11 | 0.279543E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 1743920.85 | 0.260909E+09 |
July | 0.459349E+11 | 0.287855E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 10072661.29 | 0.197969E+09 |
August | 0.461292E+11 | 0.292159E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 12516499.01 | 0.188786E+09 |
September | 0.445315E+11 | 0.286641E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 11878056.33 | 0.233403E+09 |
October | 0.459349E+11 | 0.300388E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 25097854.68 | 0.240316E+09 |
November | 0.444343E+11 | 0.291991E+10 | 0.144540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2295236.86 | 0.408878E+09 |
December | 0.459349E+11 | 0.301544E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 2945523.11 | 0.454552E+09 |
Annual Sum or Average | 0.541686E+12 | 0.348381E+11 | 0.175857E+12 | 72636491.06 | 0.411369E+10 | ||||
Minimum of Months | 0.415303E+11 | 0.270213E+10 | 0.134904E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 292897.57 | 0.188786E+09 |
Maximum of Months | 0.461292E+11 | 0.302136E+10 | 0.149358E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 25097854.68 | 0.499105E+09 |
Report: SpaceGainsMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.408770E+10 | 0.113146E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 604363.63 | 0.428054E+09 |
February | 0.369574E+10 | 0.102161E+10 | 0.301256E+11 | 0.275852E+11 | 0.00 | 0.00 | 0.00 | 80048.00 | 0.385224E+09 |
March | 0.410499E+10 | 0.113539E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.452058E+09 |
April | 0.396281E+10 | 0.109310E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 607790.63 | 0.334269E+09 |
May | 0.409635E+10 | 0.113343E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.332955E+09 |
June | 0.397146E+10 | 0.109811E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 43697.84 | 0.235189E+09 |
July | 0.408770E+10 | 0.112841E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 3744670.85 | 0.172710E+09 |
August | 0.410499E+10 | 0.113539E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 4241168.95 | 0.163567E+09 |
September | 0.396281E+10 | 0.109310E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 9457351.39 | 0.211161E+09 |
October | 0.408770E+10 | 0.113146E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 16661764.99 | 0.215029E+09 |
November | 0.395417E+10 | 0.109724E+10 | 0.322775E+11 | 0.295556E+11 | 0.00 | 0.00 | 0.00 | 745668.94 | 0.372584E+09 |
December | 0.408770E+10 | 0.112841E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 452010.77 | 0.412626E+09 |
Annual Sum or Average | 0.482041E+11 | 0.133271E+11 | 0.392709E+12 | 0.359593E+12 | 36638535.99 | 0.371542E+10 | |||
Minimum of Months | 0.369574E+10 | 0.102161E+10 | 0.301256E+11 | 0.275852E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.163567E+09 |
Maximum of Months | 0.410499E+10 | 0.113539E+10 | 0.333534E+11 | 0.305408E+11 | 0.00 | 0.00 | 0.00 | 16661764.99 | 0.452058E+09 |
Report: SpaceGainsMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.141237E+10 | 0.105898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4064811.18 | 0.241392E+09 |
February | 0.00 | 0.127524E+10 | 0.956227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 721810.63 | 0.212601E+09 |
March | 0.00 | 0.141726E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1287979.51 | 0.254045E+09 |
April | 0.00 | 0.136448E+10 | 0.102351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4359499.25 | 0.175322E+09 |
May | 0.00 | 0.141481E+10 | 0.106025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1464419.31 | 0.171141E+09 |
June | 0.00 | 0.137074E+10 | 0.102685E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6477411.86 | 0.113123E+09 |
July | 0.00 | 0.140856E+10 | 0.105691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17458925.72 | 78706113.36 |
August | 0.00 | 0.141726E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20777874.98 | 74356219.87 |
September | 0.00 | 0.136448E+10 | 0.102351E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13984206.14 | 97599932.75 |
October | 0.00 | 0.141237E+10 | 0.105898E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23250027.84 | 0.106193E+09 |
November | 0.00 | 0.136965E+10 | 0.102637E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3090493.81 | 0.204659E+09 |
December | 0.00 | 0.140856E+10 | 0.105691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4229338.10 | 0.231222E+09 |
Annual Sum or Average | 0.166358E+11 | 0.124715E+11 | 0.101167E+09 | 0.196036E+10 | |||||
Minimum of Months | 0.00 | 0.127524E+10 | 0.956227E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 721810.63 | 74356219.87 |
Maximum of Months | 0.00 | 0.141726E+10 | 0.106152E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23250027.84 | 0.254045E+09 |
Report: SpaceGainsMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.280997E+09 | 0.305485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2814385.69 | 0.165174E+09 |
February | 0.00 | 0.253715E+09 | 0.275845E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 500659.50 | 0.144918E+09 |
March | 0.00 | 0.281971E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 896451.38 | 0.173600E+09 |
April | 0.00 | 0.271470E+09 | 0.295253E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3038693.48 | 0.118444E+09 |
May | 0.00 | 0.281484E+09 | 0.305852E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1022358.09 | 0.115296E+09 |
June | 0.00 | 0.272715E+09 | 0.296217E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4575153.90 | 75569587.65 |
July | 0.00 | 0.280239E+09 | 0.304889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12237320.87 | 52115436.66 |
August | 0.00 | 0.281971E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14483829.65 | 49127068.48 |
September | 0.00 | 0.271470E+09 | 0.295253E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9723147.40 | 65156447.73 |
October | 0.00 | 0.280997E+09 | 0.305485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16075183.32 | 71145561.71 |
November | 0.00 | 0.272498E+09 | 0.296079E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2117196.79 | 0.138840E+09 |
December | 0.00 | 0.280239E+09 | 0.304889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2913779.66 | 0.157825E+09 |
Annual Sum or Average | 0.330977E+10 | 0.359769E+10 | 70398159.73 | 0.132721E+10 | |||||
Minimum of Months | 0.00 | 0.253715E+09 | 0.275845E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 500659.50 | 49127068.48 |
Maximum of Months | 0.00 | 0.281971E+09 | 0.306219E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16075183.32 | 0.173600E+09 |
Report: SpaceGainsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.232638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3073409.49 | 0.181344E+09 |
February | 0.00 | 0.210051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 579164.78 | 0.158883E+09 |
March | 0.00 | 0.233445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 956096.04 | 0.190946E+09 |
April | 0.00 | 0.224751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3347791.05 | 0.128616E+09 |
May | 0.00 | 0.233042E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1157555.03 | 0.124570E+09 |
June | 0.00 | 0.225781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5540572.11 | 78850526.99 |
July | 0.00 | 0.232011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15235841.86 | 51756241.12 |
August | 0.00 | 0.233445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17542116.97 | 49035436.19 |
September | 0.00 | 0.224751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11571623.62 | 67926012.14 |
October | 0.00 | 0.232638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19034404.49 | 72475599.64 |
November | 0.00 | 0.225602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2395501.33 | 0.149731E+09 |
December | 0.00 | 0.232011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3136715.14 | 0.172995E+09 |
Annual Sum or Average | 0.274017E+11 | 83570791.89 | 0.142713E+10 | ||||||
Minimum of Months | 0.00 | 0.210051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 579164.78 | 49035436.19 |
Maximum of Months | 0.00 | 0.233445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19034404.49 | 0.190946E+09 |
Report: SpaceGainsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.246212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4039111.44 | 0.330917E+09 |
February | 0.00 | 0.222307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 666270.99 | 0.290538E+09 |
March | 0.00 | 0.247065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 719483.98 | 0.347533E+09 |
April | 0.00 | 0.237864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3549166.24 | 0.241055E+09 |
May | 0.00 | 0.246639E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 714970.35 | 0.233880E+09 |
June | 0.00 | 0.238955E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4259660.57 | 0.154357E+09 |
July | 0.00 | 0.245548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14784124.62 | 0.109683E+09 |
August | 0.00 | 0.247065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17290249.94 | 0.104845E+09 |
September | 0.00 | 0.237864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14130968.75 | 0.135248E+09 |
October | 0.00 | 0.246212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25216604.87 | 0.143680E+09 |
November | 0.00 | 0.238765E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2780514.79 | 0.276869E+09 |
December | 0.00 | 0.245548E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3442313.23 | 0.315879E+09 |
Annual Sum or Average | 0.290004E+11 | 91593439.77 | 0.268448E+10 | ||||||
Minimum of Months | 0.00 | 0.222307E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 666270.99 | 0.104845E+09 |
Maximum of Months | 0.00 | 0.247065E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25216604.87 | 0.347533E+09 |
Report: PeakSpaceGainsMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 11501.89 | 02-JAN-00:10 | 13939.86 | 02-JAN-20:10 | 10113.80 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 11501.89 | 01-FEB-00:10 | 13939.86 | 01-FEB-20:10 | 10113.80 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11501.89 | 01-MAR-00:10 | 13939.86 | 01-MAR-20:10 | 10113.80 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 11501.89 | 01-APR-00:10 | 13939.86 | 03-APR-19:10 | 10113.80 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11501.89 | 01-MAY-00:10 | 13939.86 | 01-MAY-19:10 | 10113.80 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 11501.89 | 01-JUN-00:10 | 13939.86 | 01-JUN-19:10 | 10113.80 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 11501.89 | 01-JUL-00:10 | 13939.86 | 03-JUL-19:10 | 10113.80 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 11501.89 | 01-AUG-00:10 | 13939.86 | 01-AUG-19:10 | 10113.80 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 11501.89 | 01-SEP-00:10 | 13939.86 | 01-SEP-19:10 | 10113.80 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 11501.89 | 02-OCT-00:10 | 13939.86 | 02-OCT-19:10 | 10113.80 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 11501.89 | 01-NOV-00:10 | 13939.86 | 01-NOV-19:10 | 10113.80 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 11501.89 | 01-DEC-00:10 | 13939.86 | 01-DEC-20:10 | 10113.80 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 11501.89 | 13939.86 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 11501.89 | 13939.86 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1169.53 | 02-JAN-00:10 | 736.82 | 02-JAN-20:10 | 685.60 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 78.30 | 15-JAN-10:00 | 470.94 | 08-JAN-07:00 |
February | 1169.53 | 01-FEB-00:10 | 736.82 | 01-FEB-20:10 | 685.60 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.16 | 01-FEB-12:00 | 388.47 | 04-FEB-05:55 |
March | 1169.53 | 01-MAR-00:10 | 736.82 | 01-MAR-20:10 | 685.60 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.87 | 11-MAR-11:00 | 415.76 | 08-MAR-02:00 |
April | 1169.53 | 01-APR-00:10 | 736.82 | 03-APR-19:10 | 685.60 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 115.89 | 26-APR-13:00 | 337.00 | 01-APR-06:00 |
May | 1169.53 | 01-MAY-00:10 | 736.82 | 01-MAY-19:10 | 685.60 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 56.90 | 03-MAY-12:00 | 313.62 | 15-MAY-02:00 |
June | 1169.53 | 01-JUN-00:10 | 736.82 | 01-JUN-19:10 | 685.60 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.13 | 29-JUN-11:00 | 239.02 | 13-JUN-04:10 |
July | 1169.53 | 01-JUL-00:10 | 736.82 | 03-JUL-19:10 | 685.60 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 149.51 | 19-JUL-11:00 | 188.60 | 06-JUL-01:00 |
August | 1169.53 | 01-AUG-00:10 | 736.82 | 01-AUG-19:10 | 685.60 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.45 | 14-AUG-11:00 | 164.36 | 31-AUG-04:00 |
September | 1169.53 | 01-SEP-00:10 | 736.82 | 01-SEP-19:10 | 685.60 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 262.53 | 29-SEP-11:00 | 237.32 | 20-SEP-03:50 |
October | 1169.53 | 02-OCT-00:10 | 736.82 | 02-OCT-19:10 | 685.60 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 283.13 | 16-OCT-11:00 | 288.06 | 30-OCT-04:00 |
November | 1169.53 | 01-NOV-00:10 | 736.82 | 01-NOV-19:10 | 685.60 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.43 | 19-NOV-13:00 | 348.71 | 29-NOV-23:00 |
December | 1169.53 | 01-DEC-00:10 | 736.82 | 01-DEC-20:10 | 685.60 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.79 | 05-DEC-10:00 | 389.45 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1169.53 | 736.82 | 685.60 | 0.00 | 0.00 | 0.00 | 0.00 | 22.87 | 164.36 | |||||
Maximum of Months | 1169.53 | 736.82 | 685.60 | 0.00 | 0.00 | 0.00 | 0.00 | 283.13 | 470.94 |
Report: PeakSpaceGainsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1354.32 | 02-JAN-00:10 | 853.24 | 02-JAN-20:10 | 793.93 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.49 | 18-JAN-13:00 | 103.83 | 08-JAN-07:00 |
February | 1354.32 | 01-FEB-00:10 | 853.24 | 01-FEB-20:10 | 793.93 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.08 | 01-FEB-12:00 | 85.25 | 04-FEB-05:55 |
March | 1354.32 | 01-MAR-00:10 | 853.24 | 01-MAR-20:10 | 793.93 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.27 | 11-MAR-11:10 | 87.26 | 08-MAR-02:00 |
April | 1354.32 | 01-APR-00:10 | 853.24 | 03-APR-19:10 | 793.93 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.29 | 26-APR-13:00 | 71.60 | 01-APR-06:00 |
May | 1354.32 | 01-MAY-00:10 | 853.24 | 01-MAY-19:10 | 793.93 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.50 | 03-MAY-12:00 | 71.06 | 19-MAY-05:00 |
June | 1354.32 | 01-JUN-00:10 | 853.24 | 01-JUN-19:10 | 793.93 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 17.93 | 29-JUN-11:00 | 56.57 | 13-JUN-05:00 |
July | 1354.32 | 01-JUL-00:10 | 853.24 | 03-JUL-19:10 | 793.93 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.05 | 31-JUL-12:00 | 46.76 | 06-JUL-01:00 |
August | 1354.32 | 01-AUG-00:10 | 853.24 | 01-AUG-19:10 | 793.93 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.15 | 14-AUG-11:00 | 41.21 | 28-AUG-06:00 |
September | 1354.32 | 01-SEP-00:10 | 853.24 | 01-SEP-19:10 | 793.93 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 65.25 | 29-SEP-11:00 | 56.91 | 20-SEP-03:00 |
October | 1354.32 | 02-OCT-00:10 | 853.24 | 02-OCT-19:10 | 793.93 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.11 | 16-OCT-11:00 | 67.71 | 30-OCT-03:00 |
November | 1354.32 | 01-NOV-00:10 | 853.24 | 01-NOV-19:10 | 793.93 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.75 | 19-NOV-13:00 | 81.85 | 29-NOV-23:00 |
December | 1354.32 | 01-DEC-00:10 | 853.24 | 01-DEC-20:10 | 793.93 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 20.41 | 16-DEC-13:00 | 85.09 | 03-DEC-01:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1354.32 | 853.24 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 12.27 | 41.21 | |||||
Maximum of Months | 1354.32 | 853.24 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 68.11 | 103.83 |
Report: PeakSpaceGainsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 907.20 | 02-JAN-00:10 | 408.24 | 02-JAN-20:10 | 4572.80 | 02-JAN-20:10 | 39726.58 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 73.25 | 18-JAN-13:00 | 299.03 | 08-JAN-07:10 |
February | 907.20 | 01-FEB-00:10 | 408.24 | 01-FEB-20:10 | 4572.80 | 01-FEB-20:10 | 39726.58 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 72.78 | 01-FEB-12:00 | 264.32 | 06-FEB-23:00 |
March | 907.20 | 01-MAR-00:10 | 408.24 | 01-MAR-20:10 | 4572.80 | 01-MAR-20:10 | 39726.58 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 44.10 | 11-MAR-12:40 | 283.64 | 29-MAR-22:00 |
April | 907.20 | 01-APR-00:10 | 408.24 | 03-APR-19:10 | 4572.80 | 03-APR-19:10 | 39726.58 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 86.89 | 26-APR-13:00 | 231.67 | 15-APR-22:00 |
May | 907.20 | 01-MAY-00:10 | 408.24 | 01-MAY-19:10 | 4572.80 | 01-MAY-19:10 | 39726.58 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 44.17 | 03-MAY-12:50 | 214.94 | 15-MAY-05:10 |
June | 907.20 | 01-JUN-00:10 | 408.24 | 01-JUN-19:10 | 4572.80 | 01-JUN-19:10 | 39726.58 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 58.50 | 29-JUN-11:00 | 184.79 | 12-JUN-21:00 |
July | 907.20 | 01-JUL-00:10 | 408.24 | 03-JUL-19:10 | 4572.80 | 03-JUL-19:10 | 39726.58 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 101.32 | 19-JUL-11:10 | 136.22 | 08-JUL-21:00 |
August | 907.20 | 01-AUG-00:10 | 408.24 | 01-AUG-19:10 | 4572.80 | 01-AUG-19:10 | 39726.58 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 101.62 | 18-AUG-12:00 | 150.87 | 28-AUG-07:00 |
September | 907.20 | 01-SEP-00:10 | 408.24 | 01-SEP-19:10 | 4572.80 | 01-SEP-19:10 | 39726.58 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 211.11 | 29-SEP-11:10 | 178.81 | 20-SEP-06:10 |
October | 907.20 | 02-OCT-00:10 | 408.24 | 02-OCT-19:10 | 4572.80 | 02-OCT-19:10 | 39726.58 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 224.82 | 16-OCT-11:00 | 218.95 | 12-OCT-06:00 |
November | 907.20 | 01-NOV-00:10 | 408.24 | 01-NOV-19:10 | 4572.80 | 01-NOV-19:10 | 39726.58 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 87.00 | 19-NOV-13:00 | 265.27 | 23-NOV-22:00 |
December | 907.20 | 01-DEC-00:10 | 408.24 | 01-DEC-20:10 | 4572.80 | 01-DEC-20:10 | 39726.58 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 73.16 | 16-DEC-13:00 | 281.18 | 12-DEC-22:00 |
Annual Sum or Average | |||||||||||||||
Minimum of Months | 907.20 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 44.10 | 136.22 | ||||||
Maximum of Months | 907.20 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 224.82 | 299.03 |
Report: PeakSpaceGainsMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 15368.40 | 02-JAN-00:10 | 1761.91 | 02-JAN-20:10 | 965.27 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 198.43 | 15-JAN-14:00 | 1248.74 | 08-JAN-07:00 |
February | 15368.40 | 01-FEB-00:10 | 1761.91 | 01-FEB-20:10 | 965.27 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 137.85 | 01-FEB-12:00 | 1027.91 | 04-FEB-05:55 |
March | 15368.40 | 01-MAR-00:10 | 1761.91 | 01-MAR-20:10 | 965.27 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 49.58 | 11-MAR-11:00 | 1049.22 | 08-MAR-02:00 |
April | 15368.40 | 01-APR-00:10 | 1761.91 | 03-APR-19:10 | 965.27 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 308.03 | 26-APR-13:00 | 850.55 | 01-APR-06:00 |
May | 15368.40 | 01-MAY-00:10 | 1761.91 | 01-MAY-19:10 | 965.27 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 154.96 | 03-MAY-13:00 | 860.29 | 19-MAY-05:00 |
June | 15368.40 | 01-JUN-00:10 | 1761.91 | 01-JUN-19:10 | 965.27 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 228.42 | 29-JUN-11:00 | 711.23 | 13-JUN-05:00 |
July | 15368.40 | 01-JUL-00:10 | 1761.91 | 03-JUL-19:10 | 965.27 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 386.78 | 19-JUL-11:00 | 585.64 | 06-JUL-01:00 |
August | 15368.40 | 01-AUG-00:10 | 1761.91 | 01-AUG-19:10 | 965.27 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 374.28 | 14-AUG-11:00 | 530.70 | 28-AUG-05:00 |
September | 15368.40 | 01-SEP-00:10 | 1761.91 | 01-SEP-19:10 | 965.27 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 686.51 | 29-SEP-11:00 | 717.40 | 20-SEP-03:00 |
October | 15368.40 | 02-OCT-00:10 | 1761.91 | 02-OCT-19:10 | 965.27 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 714.56 | 16-OCT-11:00 | 853.38 | 30-OCT-03:00 |
November | 15368.40 | 01-NOV-00:10 | 1761.91 | 01-NOV-19:10 | 965.27 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 170.25 | 19-NOV-13:00 | 983.26 | 29-NOV-23:00 |
December | 15368.40 | 01-DEC-00:10 | 1761.91 | 01-DEC-20:10 | 965.27 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 134.82 | 05-DEC-10:00 | 1011.83 | 23-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 15368.40 | 1761.91 | 965.27 | 0.00 | 0.00 | 0.00 | 0.00 | 49.58 | 530.70 | |||||
Maximum of Months | 15368.40 | 1761.91 | 965.27 | 0.00 | 0.00 | 0.00 | 0.00 | 714.56 | 1248.74 |
Report: PeakSpaceGainsMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 45622.98 | 02-JAN-00:10 | 12090.12 | 02-JAN-20:10 | 10029.21 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 474.16 | 13-JAN-14:00 | 2490.07 | 08-JAN-07:00 |
February | 45622.98 | 01-FEB-00:10 | 12090.12 | 01-FEB-20:10 | 10029.21 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 447.20 | 01-FEB-12:00 | 2116.73 | 04-FEB-05:55 |
March | 45622.98 | 01-MAR-00:10 | 12090.12 | 01-MAR-20:10 | 10029.21 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 233.89 | 11-MAR-11:10 | 2147.18 | 08-MAR-02:00 |
April | 45622.98 | 01-APR-00:10 | 12090.12 | 03-APR-19:10 | 10029.21 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 649.92 | 26-APR-13:00 | 1784.37 | 01-APR-06:00 |
May | 45622.98 | 01-MAY-00:10 | 12090.12 | 01-MAY-19:10 | 10029.21 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 319.51 | 03-MAY-13:00 | 1778.01 | 19-MAY-05:00 |
June | 45622.98 | 01-JUN-00:10 | 12090.12 | 01-JUN-19:10 | 10029.21 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 432.19 | 29-JUN-11:00 | 1452.16 | 13-JUN-05:00 |
July | 45622.98 | 01-JUL-00:10 | 12090.12 | 03-JUL-19:10 | 10029.21 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 764.46 | 31-JUL-13:00 | 1189.43 | 06-JUL-01:00 |
August | 45622.98 | 01-AUG-00:10 | 12090.12 | 01-AUG-19:10 | 10029.21 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 763.33 | 14-AUG-11:00 | 1062.07 | 28-AUG-05:00 |
September | 45622.98 | 01-SEP-00:10 | 12090.12 | 01-SEP-19:10 | 10029.21 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1526.45 | 29-SEP-11:00 | 1447.78 | 20-SEP-03:00 |
October | 45622.98 | 02-OCT-00:10 | 12090.12 | 02-OCT-19:10 | 10029.21 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1586.22 | 16-OCT-11:00 | 1711.59 | 30-OCT-03:00 |
November | 45622.98 | 01-NOV-00:10 | 12090.12 | 01-NOV-19:10 | 10029.21 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 476.99 | 19-NOV-13:00 | 2011.75 | 29-NOV-23:00 |
December | 45622.98 | 01-DEC-00:10 | 12090.12 | 01-DEC-20:10 | 10029.21 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 418.35 | 05-DEC-10:00 | 2077.04 | 23-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 45622.98 | 12090.12 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 233.89 | 1062.07 | |||||
Maximum of Months | 45622.98 | 12090.12 | 10029.21 | 0.00 | 0.00 | 0.00 | 0.00 | 1586.22 | 2490.07 |
Report: PeakSpaceGainsMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 142.14 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 32.30 | 14-JAN-11:00 | 146.56 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 142.14 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.00 | 01-FEB-10:00 | 115.29 | 04-FEB-05:55 |
March | 180.00 | 01-MAR-00:10 | 142.14 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 11-MAR-11:00 | 123.32 | 08-MAR-04:00 |
April | 180.00 | 01-APR-00:10 | 142.14 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.73 | 30-APR-10:02 | 100.15 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 142.14 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.39 | 03-MAY-10:00 | 93.26 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 142.14 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 26-JUN-10:00 | 71.32 | 13-JUN-04:40 |
July | 180.00 | 01-JUL-00:10 | 142.14 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.66 | 19-JUL-10:00 | 56.51 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 142.14 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.66 | 15-AUG-10:00 | 49.81 | 28-AUG-07:10 |
September | 180.00 | 01-SEP-00:10 | 142.14 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.04 | 29-SEP-10:00 | 70.82 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 142.14 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.27 | 16-OCT-10:01 | 85.75 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 142.14 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.22 | 19-NOV-10:10 | 100.61 | 24-NOV-01:00 |
December | 180.00 | 01-DEC-00:10 | 142.14 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.28 | 05-DEC-10:00 | 115.58 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 142.14 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 12.39 | 49.81 | |||||
Maximum of Months | 180.00 | 142.14 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 89.27 | 146.56 |
Report: PeakSpaceGainsMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 142.12 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 32.30 | 14-JAN-11:00 | 146.55 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 142.12 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 28.33 | 01-FEB-12:00 | 115.28 | 04-FEB-05:55 |
March | 180.00 | 01-MAR-00:10 | 142.12 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 11-MAR-11:00 | 123.31 | 08-MAR-04:00 |
April | 180.00 | 01-APR-00:10 | 142.12 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.58 | 26-APR-13:00 | 100.14 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 142.12 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.40 | 03-MAY-10:00 | 93.25 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 142.12 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 30-JUN-10:00 | 71.31 | 13-JUN-04:50 |
July | 180.00 | 01-JUL-00:10 | 142.12 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.65 | 19-JUL-10:00 | 56.50 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 142.12 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.66 | 15-AUG-10:00 | 49.44 | 28-AUG-07:10 |
September | 180.00 | 01-SEP-00:10 | 142.12 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.03 | 29-SEP-10:00 | 70.82 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 142.12 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 90.04 | 16-OCT-10:01 | 85.75 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 142.12 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.22 | 19-NOV-10:00 | 100.61 | 24-NOV-00:55 |
December | 180.00 | 01-DEC-00:10 | 142.12 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.28 | 05-DEC-10:00 | 115.57 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 142.12 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 12.40 | 49.44 | |||||
Maximum of Months | 180.00 | 142.12 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 90.04 | 146.55 |
Report: PeakSpaceGainsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 89.33 | 01-JAN-19:10 | 232.19 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4.88 | 14-JAN-11:00 | 40.52 | 08-JAN-07:00 |
February | 0.00 | 01-FEB-00:10 | 89.33 | 01-FEB-20:10 | 232.19 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.85 | 01-FEB-12:00 | 33.78 | 04-FEB-05:55 |
March | 0.00 | 01-MAR-00:10 | 89.33 | 01-MAR-20:10 | 232.19 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.16 | 11-MAR-11:45 | 34.40 | 08-MAR-02:00 |
April | 0.00 | 01-APR-00:10 | 89.33 | 01-APR-18:10 | 232.19 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.70 | 26-APR-13:00 | 27.05 | 15-APR-22:00 |
May | 0.00 | 01-MAY-00:10 | 89.33 | 01-MAY-19:10 | 232.19 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1.24 | 03-MAY-12:00 | 25.42 | 27-MAY-03:00 |
June | 0.00 | 01-JUN-00:10 | 89.33 | 01-JUN-19:10 | 232.19 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.28 | 29-JUN-11:00 | 20.38 | 12-JUN-21:00 |
July | 0.00 | 01-JUL-00:10 | 89.33 | 01-JUL-18:10 | 232.19 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.75 | 19-JUL-11:00 | 17.64 | 06-JUL-01:00 |
August | 0.00 | 01-AUG-00:10 | 89.33 | 01-AUG-19:10 | 232.19 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.52 | 18-AUG-12:00 | 18.00 | 28-AUG-07:00 |
September | 0.00 | 01-SEP-00:10 | 89.33 | 01-SEP-19:10 | 232.19 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22.58 | 29-SEP-11:00 | 22.45 | 20-SEP-03:00 |
October | 0.00 | 01-OCT-00:10 | 89.33 | 01-OCT-18:10 | 232.19 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.34 | 16-OCT-11:00 | 27.00 | 30-OCT-03:00 |
November | 0.00 | 01-NOV-00:10 | 89.33 | 01-NOV-19:10 | 232.19 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.68 | 19-NOV-13:00 | 32.47 | 23-NOV-22:00 |
December | 0.00 | 01-DEC-00:10 | 89.33 | 01-DEC-20:10 | 232.19 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.88 | 16-DEC-13:00 | 34.74 | 03-DEC-01:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 0.00 | 89.33 | 232.19 | 0.00 | 0.00 | 0.00 | 0.00 | 1.16 | 17.64 | |||||
Maximum of Months | 0.00 | 89.33 | 232.19 | 0.00 | 0.00 | 0.00 | 0.00 | 24.34 | 40.52 |
Report: PeakSpaceGainsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 89.35 | 01-JAN-19:10 | 232.26 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.09 | 13-JAN-14:00 | 40.90 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 89.35 | 01-FEB-20:10 | 232.26 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8.45 | 01-FEB-12:00 | 32.18 | 04-FEB-06:00 |
March | 180.00 | 01-MAR-00:10 | 89.35 | 01-MAR-20:10 | 232.26 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.31 | 11-MAR-11:00 | 34.42 | 08-MAR-04:00 |
April | 180.00 | 01-APR-00:10 | 89.35 | 01-APR-18:10 | 232.26 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.34 | 26-APR-13:00 | 27.95 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 89.35 | 01-MAY-19:10 | 232.26 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.05 | 03-MAY-12:00 | 26.03 | 15-MAY-02:00 |
June | 180.00 | 01-JUN-00:10 | 89.35 | 01-JUN-19:10 | 232.26 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5.91 | 29-JUN-11:00 | 19.90 | 13-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 89.35 | 01-JUL-18:10 | 232.26 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.02 | 19-JUL-11:00 | 15.77 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 89.35 | 01-AUG-19:10 | 232.26 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 11.10 | 14-AUG-11:00 | 14.05 | 28-AUG-07:10 |
September | 180.00 | 01-SEP-00:10 | 89.35 | 01-SEP-19:10 | 232.26 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24.97 | 29-SEP-10:02 | 19.77 | 20-SEP-03:50 |
October | 180.00 | 01-OCT-00:10 | 89.35 | 01-OCT-18:10 | 232.26 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.09 | 16-OCT-11:00 | 23.93 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 89.35 | 01-NOV-19:10 | 232.26 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.70 | 19-NOV-13:00 | 28.08 | 24-NOV-01:00 |
December | 180.00 | 01-DEC-00:10 | 89.35 | 01-DEC-20:10 | 232.26 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.01 | 05-DEC-10:00 | 32.26 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 89.35 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 4.05 | 14.05 | |||||
Maximum of Months | 180.00 | 89.35 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 26.09 | 40.90 |
Report: PeakSpaceGainsMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 142.14 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 32.30 | 14-JAN-11:00 | 146.56 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 142.14 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.00 | 01-FEB-10:00 | 115.29 | 04-FEB-06:00 |
March | 180.00 | 01-MAR-00:10 | 142.14 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 11-MAR-11:00 | 123.32 | 08-MAR-02:00 |
April | 180.00 | 01-APR-00:10 | 142.14 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.67 | 30-APR-10:00 | 100.15 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 142.14 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.40 | 03-MAY-10:00 | 93.26 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 142.14 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 30-JUN-10:00 | 71.32 | 13-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 142.14 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.65 | 19-JUL-10:00 | 56.51 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 142.14 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.66 | 15-AUG-10:00 | 55.65 | 28-AUG-07:20 |
September | 180.00 | 01-SEP-00:10 | 142.14 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.04 | 29-SEP-10:00 | 70.82 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 142.14 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.22 | 16-OCT-10:00 | 85.75 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 142.14 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.22 | 19-NOV-10:00 | 100.61 | 24-NOV-00:55 |
December | 180.00 | 01-DEC-00:10 | 142.14 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.28 | 05-DEC-10:00 | 115.58 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 142.14 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 12.40 | 55.65 | |||||
Maximum of Months | 180.00 | 142.14 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 89.22 | 146.56 |
Report: PeakSpaceGainsMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 142.12 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 32.30 | 14-JAN-11:00 | 146.55 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 142.12 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.18 | 01-FEB-12:00 | 115.28 | 04-FEB-05:55 |
March | 180.00 | 01-MAR-00:10 | 142.12 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 11-MAR-11:00 | 123.31 | 08-MAR-04:00 |
April | 180.00 | 01-APR-00:10 | 142.12 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.67 | 30-APR-10:00 | 100.14 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 142.12 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.40 | 03-MAY-10:00 | 93.25 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 142.12 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.01 | 26-JUN-10:00 | 71.31 | 13-JUN-05:00 |
July | 180.00 | 01-JUL-00:10 | 142.12 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.65 | 19-JUL-10:00 | 56.50 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 142.12 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.66 | 15-AUG-10:00 | 55.19 | 28-AUG-07:20 |
September | 180.00 | 01-SEP-00:10 | 142.12 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.04 | 29-SEP-10:00 | 70.82 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 142.12 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.30 | 16-OCT-10:01 | 85.75 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 142.12 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.22 | 19-NOV-10:00 | 100.61 | 24-NOV-00:55 |
December | 180.00 | 01-DEC-00:10 | 142.12 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 32.28 | 05-DEC-10:00 | 115.57 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 142.12 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 12.40 | 55.19 | |||||
Maximum of Months | 180.00 | 142.12 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 89.30 | 146.55 |
Report: PeakSpaceGainsMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 142.14 | 01-JAN-19:10 | 237.06 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 31.91 | 14-JAN-11:00 | 147.03 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 142.14 | 01-FEB-20:10 | 237.06 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 | 01-FEB-10:00 | 115.75 | 04-FEB-06:00 |
March | 180.00 | 01-MAR-00:10 | 142.14 | 01-MAR-20:10 | 237.06 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 11-MAR-11:00 | 123.78 | 08-MAR-02:00 |
April | 180.00 | 01-APR-00:10 | 142.14 | 01-APR-18:10 | 237.06 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.28 | 30-APR-10:00 | 100.60 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 142.14 | 01-MAY-19:10 | 237.06 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 03-MAY-10:00 | 93.70 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 142.14 | 01-JUN-19:10 | 237.06 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 26-JUN-10:00 | 71.75 | 13-JUN-04:40 |
July | 180.00 | 01-JUL-00:10 | 142.14 | 01-JUL-18:10 | 237.06 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.27 | 19-JUL-10:00 | 56.93 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 142.14 | 01-AUG-19:10 | 237.06 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.28 | 15-AUG-10:00 | 49.92 | 28-AUG-07:10 |
September | 180.00 | 01-SEP-00:10 | 142.14 | 01-SEP-19:10 | 237.06 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.68 | 29-SEP-10:00 | 71.25 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 142.14 | 01-OCT-18:10 | 237.06 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.86 | 16-OCT-10:00 | 86.20 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 142.14 | 01-NOV-19:10 | 237.06 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.83 | 19-NOV-10:00 | 101.06 | 24-NOV-00:55 |
December | 180.00 | 01-DEC-00:10 | 142.14 | 01-DEC-20:10 | 237.06 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.89 | 05-DEC-10:00 | 116.04 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 142.14 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 49.92 | |||||
Maximum of Months | 180.00 | 142.14 | 237.06 | 0.00 | 0.00 | 0.00 | 0.00 | 88.86 | 147.03 |
Report: PeakSpaceGainsMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 142.12 | 01-JAN-19:10 | 237.03 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 31.91 | 14-JAN-11:00 | 147.02 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 142.12 | 01-FEB-20:10 | 237.03 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 27.13 | 01-FEB-12:00 | 115.73 | 04-FEB-05:55 |
March | 180.00 | 01-MAR-00:10 | 142.12 | 01-MAR-20:10 | 237.03 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 | 11-MAR-11:00 | 123.77 | 08-MAR-04:00 |
April | 180.00 | 01-APR-00:10 | 142.12 | 01-APR-18:10 | 237.03 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.28 | 30-APR-10:00 | 100.59 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 142.12 | 01-MAY-19:10 | 237.03 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 03-MAY-10:00 | 93.69 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 142.12 | 01-JUN-19:10 | 237.03 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.62 | 26-JUN-10:00 | 71.75 | 13-JUN-04:40 |
July | 180.00 | 01-JUL-00:10 | 142.12 | 01-JUL-18:10 | 237.03 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.27 | 19-JUL-10:00 | 56.93 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 142.12 | 01-AUG-19:10 | 237.03 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.28 | 15-AUG-10:00 | 49.78 | 24-AUG-02:00 |
September | 180.00 | 01-SEP-00:10 | 142.12 | 01-SEP-19:10 | 237.03 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.67 | 29-SEP-10:00 | 71.25 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 142.12 | 01-OCT-18:10 | 237.03 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.43 | 16-OCT-10:01 | 86.19 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 142.12 | 01-NOV-19:10 | 237.03 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.83 | 19-NOV-10:00 | 101.05 | 24-NOV-00:55 |
December | 180.00 | 01-DEC-00:10 | 142.12 | 01-DEC-20:10 | 237.03 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.89 | 05-DEC-10:00 | 116.02 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 142.12 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 12.00 | 49.78 | |||||
Maximum of Months | 180.00 | 142.12 | 237.03 | 0.00 | 0.00 | 0.00 | 0.00 | 89.43 | 147.02 |
Report: PeakSpaceGainsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 180.00 | 01-JAN-00:10 | 89.35 | 01-JAN-19:10 | 232.26 | 01-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.32 | 14-JAN-11:00 | 75.22 | 08-JAN-07:00 |
February | 180.00 | 01-FEB-00:10 | 89.35 | 01-FEB-20:10 | 232.26 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.52 | 01-FEB-10:00 | 59.21 | 04-FEB-05:55 |
March | 180.00 | 01-MAR-00:10 | 89.35 | 01-MAR-20:10 | 232.26 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.52 | 11-MAR-11:00 | 63.32 | 08-MAR-04:00 |
April | 180.00 | 01-APR-00:10 | 89.35 | 01-APR-18:10 | 232.26 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 12.93 | 30-APR-10:00 | 51.46 | 01-APR-06:00 |
May | 180.00 | 01-MAY-00:10 | 89.35 | 01-MAY-19:10 | 232.26 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.14 | 03-MAY-10:00 | 47.94 | 15-MAY-05:00 |
June | 180.00 | 01-JUN-00:10 | 89.35 | 01-JUN-19:10 | 232.26 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.53 | 26-JUN-10:00 | 36.71 | 13-JUN-04:40 |
July | 180.00 | 01-JUL-00:10 | 89.35 | 01-JUL-18:10 | 232.26 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.58 | 19-JUL-10:00 | 29.13 | 06-JUL-01:00 |
August | 180.00 | 01-AUG-00:10 | 89.35 | 01-AUG-19:10 | 232.26 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.58 | 15-AUG-10:00 | 25.95 | 28-AUG-07:10 |
September | 180.00 | 01-SEP-00:10 | 89.35 | 01-SEP-19:10 | 232.26 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.37 | 29-SEP-10:00 | 36.45 | 20-SEP-03:10 |
October | 180.00 | 01-OCT-00:10 | 89.35 | 01-OCT-18:10 | 232.26 | 01-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.46 | 16-OCT-10:00 | 44.10 | 30-OCT-04:00 |
November | 180.00 | 01-NOV-00:10 | 89.35 | 01-NOV-19:10 | 232.26 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.28 | 19-NOV-10:00 | 51.70 | 24-NOV-01:00 |
December | 180.00 | 01-DEC-00:10 | 89.35 | 01-DEC-20:10 | 232.26 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.31 | 05-DEC-10:00 | 59.36 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 180.00 | 89.35 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 6.14 | 25.95 | |||||
Maximum of Months | 180.00 | 89.35 | 232.26 | 0.00 | 0.00 | 0.00 | 0.00 | 45.46 | 75.22 |
Report: PeakSpaceGainsMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 26988.77 | 02-JAN-00:10 | 3094.06 | 02-JAN-20:10 | 6747.90 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.80 | 13-JAN-14:00 | 357.04 | 08-JAN-07:00 |
February | 26988.77 | 01-FEB-00:10 | 3094.06 | 01-FEB-20:10 | 6747.90 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 63.37 | 01-FEB-12:00 | 314.15 | 04-FEB-05:55 |
March | 26988.77 | 01-MAR-00:10 | 3094.06 | 01-MAR-20:10 | 6747.90 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 23.15 | 11-MAR-14:00 | 323.80 | 08-MAR-02:00 |
April | 26988.77 | 01-APR-00:10 | 3094.06 | 03-APR-19:10 | 6747.90 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 74.57 | 26-APR-13:00 | 281.83 | 01-APR-06:00 |
May | 26988.77 | 01-MAY-00:10 | 3094.06 | 01-MAY-19:10 | 6747.90 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.14 | 03-MAY-13:00 | 275.38 | 15-MAY-02:00 |
June | 26988.77 | 01-JUN-00:10 | 3094.06 | 01-JUN-19:10 | 6747.90 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 41.00 | 29-JUN-11:00 | 224.66 | 13-JUN-04:40 |
July | 26988.77 | 01-JUL-00:10 | 3094.06 | 03-JUL-19:10 | 6747.90 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 88.03 | 31-JUL-12:00 | 187.81 | 06-JUL-01:00 |
August | 26988.77 | 01-AUG-00:10 | 3094.06 | 01-AUG-19:10 | 6747.90 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 89.52 | 14-AUG-11:00 | 170.14 | 24-AUG-02:00 |
September | 26988.77 | 01-SEP-00:10 | 3094.06 | 01-SEP-19:10 | 6747.90 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 208.83 | 29-SEP-11:00 | 223.13 | 20-SEP-03:10 |
October | 26988.77 | 02-OCT-00:10 | 3094.06 | 02-OCT-19:10 | 6747.90 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 223.85 | 16-OCT-11:00 | 260.14 | 30-OCT-04:00 |
November | 26988.77 | 01-NOV-00:10 | 3094.06 | 01-NOV-19:10 | 6747.90 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 68.88 | 19-NOV-13:00 | 296.36 | 29-NOV-23:00 |
December | 26988.77 | 01-DEC-00:10 | 3094.06 | 01-DEC-20:10 | 6747.90 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 62.66 | 19-DEC-13:00 | 309.64 | 23-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 23.15 | 170.14 | |||||
Maximum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 223.85 | 357.04 |
Report: PeakSpaceGainsMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 26988.77 | 02-JAN-00:10 | 3094.06 | 02-JAN-20:10 | 6747.90 | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.14 | 13-JAN-14:00 | 357.10 | 08-JAN-07:00 |
February | 26988.77 | 01-FEB-00:10 | 3094.06 | 01-FEB-20:10 | 6747.90 | 01-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.53 | 01-FEB-12:00 | 316.57 | 04-FEB-05:55 |
March | 26988.77 | 01-MAR-00:10 | 3094.06 | 01-MAR-20:10 | 6747.90 | 01-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 | 11-MAR-14:00 | 326.86 | 08-MAR-02:00 |
April | 26988.77 | 01-APR-00:10 | 3094.06 | 03-APR-19:10 | 6747.90 | 01-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.93 | 26-APR-13:00 | 285.54 | 01-APR-06:00 |
May | 26988.77 | 01-MAY-00:10 | 3094.06 | 01-MAY-19:10 | 6747.90 | 01-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.65 | 03-MAY-13:00 | 278.09 | 15-MAY-02:00 |
June | 26988.77 | 01-JUN-00:10 | 3094.06 | 01-JUN-19:10 | 6747.90 | 01-JUN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.57 | 29-JUN-11:00 | 224.67 | 13-JUN-04:40 |
July | 26988.77 | 01-JUL-00:10 | 3094.06 | 03-JUL-19:10 | 6747.90 | 01-JUL-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 83.93 | 31-JUL-13:00 | 187.81 | 06-JUL-01:00 |
August | 26988.77 | 01-AUG-00:10 | 3094.06 | 01-AUG-19:10 | 6747.90 | 01-AUG-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 85.33 | 17-AUG-14:00 | 170.15 | 24-AUG-02:00 |
September | 26988.77 | 01-SEP-00:10 | 3094.06 | 01-SEP-19:10 | 6747.90 | 01-SEP-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 204.60 | 29-SEP-11:00 | 223.13 | 20-SEP-03:10 |
October | 26988.77 | 02-OCT-00:10 | 3094.06 | 02-OCT-19:10 | 6747.90 | 01-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 220.21 | 16-OCT-11:00 | 260.15 | 30-OCT-04:00 |
November | 26988.77 | 01-NOV-00:10 | 3094.06 | 01-NOV-19:10 | 6747.90 | 01-NOV-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.36 | 19-NOV-13:00 | 296.80 | 23-NOV-22:00 |
December | 26988.77 | 01-DEC-00:10 | 3094.06 | 01-DEC-20:10 | 6747.90 | 01-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.28 | 19-DEC-13:00 | 312.61 | 12-DEC-22:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 18.61 | 170.15 | |||||
Maximum of Months | 26988.77 | 3094.06 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 220.21 | 357.10 |
Report: PeakSpaceGainsMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2401.70 | 02-JAN-00:10 | 1089.83 | 02-JAN-20:10 | 14912.86 | 01-JAN-07:10 | 22492.83 | 01-JAN-16:10 | 0.00 | 0.00 | 0.00 | 27.86 | 14-JAN-11:00 | 319.65 | 08-JAN-07:00 |
February | 2401.70 | 01-FEB-00:10 | 1089.83 | 01-FEB-20:10 | 14912.86 | 01-FEB-07:10 | 22492.83 | 01-FEB-16:10 | 0.00 | 0.00 | 0.00 | 27.68 | 01-FEB-12:00 | 264.59 | 06-FEB-23:00 |
March | 2401.70 | 01-MAR-00:10 | 1089.83 | 01-MAR-20:10 | 14912.86 | 01-MAR-07:10 | 22492.83 | 01-MAR-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 291.66 | 29-MAR-22:50 |
April | 2401.70 | 01-APR-00:10 | 1089.83 | 03-APR-19:10 | 14912.86 | 01-APR-06:10 | 22492.83 | 01-APR-15:09 | 0.00 | 0.00 | 0.00 | 42.04 | 26-APR-13:00 | 256.10 | 01-APR-06:00 |
May | 2401.70 | 01-MAY-00:10 | 1089.83 | 01-MAY-19:10 | 14912.86 | 01-MAY-06:10 | 22492.83 | 01-MAY-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:05 | 238.53 | 19-MAY-05:00 |
June | 2401.70 | 01-JUN-00:10 | 1089.83 | 01-JUN-19:10 | 14912.86 | 01-JUN-06:10 | 22492.83 | 01-JUN-15:09 | 0.00 | 0.00 | 0.00 | 13.25 | 29-JUN-11:00 | 201.09 | 13-JUN-05:00 |
July | 2401.70 | 01-JUL-00:10 | 1089.83 | 03-JUL-19:10 | 14912.86 | 01-JUL-06:10 | 22492.83 | 01-JUL-15:09 | 0.00 | 0.00 | 0.00 | 56.38 | 19-JUL-12:00 | 145.51 | 06-JUL-01:00 |
August | 2401.70 | 01-AUG-00:10 | 1089.83 | 01-AUG-19:10 | 14912.86 | 01-AUG-06:10 | 22492.83 | 01-AUG-15:09 | 0.00 | 0.00 | 0.00 | 56.50 | 18-AUG-12:00 | 151.84 | 28-AUG-06:10 |
September | 2401.70 | 01-SEP-00:10 | 1089.83 | 01-SEP-19:10 | 14912.86 | 01-SEP-06:10 | 22492.83 | 01-SEP-15:09 | 0.00 | 0.00 | 0.00 | 166.95 | 29-SEP-11:00 | 183.96 | 20-SEP-06:00 |
October | 2401.70 | 02-OCT-00:10 | 1089.83 | 02-OCT-19:10 | 14912.86 | 01-OCT-06:10 | 22492.83 | 01-OCT-15:09 | 0.00 | 0.00 | 0.00 | 180.76 | 16-OCT-11:00 | 232.57 | 29-OCT-06:00 |
November | 2401.70 | 01-NOV-00:10 | 1089.83 | 01-NOV-19:10 | 14912.86 | 01-NOV-06:10 | 22492.83 | 01-NOV-15:09 | 0.00 | 0.00 | 0.00 | 42.10 | 19-NOV-13:00 | 265.65 | 23-NOV-22:00 |
December | 2401.70 | 01-DEC-00:10 | 1089.83 | 01-DEC-20:10 | 14912.86 | 01-DEC-07:10 | 22492.83 | 01-DEC-16:10 | 0.00 | 0.00 | 0.00 | 27.94 | 16-DEC-13:00 | 294.09 | 22-DEC-07:00 |
Annual Sum or Average | |||||||||||||||
Minimum of Months | 2401.70 | 1089.83 | 14912.86 | 22492.83 | 0.00 | 0.00 | 0.00 | 0.00 | 145.51 | ||||||
Maximum of Months | 2401.70 | 1089.83 | 14912.86 | 22492.83 | 0.00 | 0.00 | 0.00 | 180.76 | 319.65 |
Report: PeakSpaceGainsMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 1360.40 | 02-JAN-20:10 | 839.45 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.33 | 13-JAN-14:00 | 226.78 | 08-JAN-07:00 |
February | 0.00 | 1360.40 | 01-FEB-20:10 | 839.45 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 51.11 | 01-FEB-12:00 | 179.49 | 04-FEB-06:00 |
March | 0.00 | 1360.40 | 01-MAR-20:10 | 839.45 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 31.50 | 11-MAR-11:35 | 192.09 | 08-MAR-02:00 |
April | 0.00 | 1360.40 | 03-APR-19:10 | 839.45 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.81 | 26-APR-13:00 | 155.70 | 01-APR-06:00 |
May | 0.00 | 1360.40 | 01-MAY-19:10 | 839.45 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.33 | 03-MAY-13:00 | 146.27 | 27-MAY-03:00 |
June | 0.00 | 1360.40 | 01-JUN-19:10 | 839.45 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 38.45 | 29-JUN-11:00 | 113.87 | 13-JUN-05:00 |
July | 0.00 | 1360.40 | 03-JUL-19:10 | 839.45 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 69.45 | 31-JUL-13:00 | 93.63 | 06-JUL-01:00 |
August | 0.00 | 1360.40 | 01-AUG-19:10 | 839.45 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 70.39 | 14-AUG-11:00 | 83.00 | 28-AUG-07:00 |
September | 0.00 | 1360.40 | 01-SEP-19:10 | 839.45 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 146.46 | 29-SEP-11:00 | 113.09 | 20-SEP-03:00 |
October | 0.00 | 1360.40 | 02-OCT-19:10 | 839.45 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 152.83 | 16-OCT-11:00 | 137.75 | 29-OCT-06:00 |
November | 0.00 | 1360.40 | 01-NOV-19:10 | 839.45 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 58.36 | 19-NOV-13:00 | 167.21 | 29-NOV-23:00 |
December | 0.00 | 1360.40 | 01-DEC-20:10 | 839.45 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 52.45 | 16-DEC-13:00 | 179.94 | 22-DEC-07:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 30.33 | 83.00 | ||||
Maximum of Months | 0.00 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 152.83 | 226.78 |
Report: PeakSpaceGainsMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 270.66 | 02-JAN-20:10 | 242.16 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.38 | 13-JAN-14:00 | 156.91 | 08-JAN-07:00 |
February | 0.00 | 270.66 | 01-FEB-20:10 | 242.16 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 35.18 | 01-FEB-12:00 | 124.79 | 04-FEB-05:55 |
March | 0.00 | 270.66 | 01-MAR-20:10 | 242.16 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.90 | 11-MAR-11:50 | 133.56 | 08-MAR-02:00 |
April | 0.00 | 270.66 | 03-APR-19:10 | 242.16 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 42.74 | 26-APR-13:00 | 108.26 | 01-APR-06:00 |
May | 0.00 | 270.66 | 01-MAY-19:10 | 242.16 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.03 | 03-MAY-13:00 | 100.73 | 15-MAY-02:00 |
June | 0.00 | 270.66 | 01-JUN-19:10 | 242.16 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 26.82 | 29-JUN-11:00 | 77.98 | 13-JUN-05:00 |
July | 0.00 | 270.66 | 03-JUL-19:10 | 242.16 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.00 | 31-JUL-12:00 | 63.79 | 06-JUL-01:00 |
August | 0.00 | 270.66 | 01-AUG-19:10 | 242.16 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 48.70 | 14-AUG-11:00 | 55.75 | 28-AUG-07:00 |
September | 0.00 | 270.66 | 01-SEP-19:10 | 242.16 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 100.96 | 29-SEP-11:00 | 77.66 | 20-SEP-03:00 |
October | 0.00 | 270.66 | 02-OCT-19:10 | 242.16 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.19 | 16-OCT-11:00 | 94.09 | 29-OCT-06:00 |
November | 0.00 | 270.66 | 01-NOV-19:10 | 242.16 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 40.05 | 19-NOV-13:00 | 112.89 | 29-NOV-23:00 |
December | 0.00 | 270.66 | 01-DEC-20:10 | 242.16 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.38 | 16-DEC-13:00 | 125.11 | 22-DEC-07:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 270.66 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 21.03 | 55.75 | ||||
Maximum of Months | 0.00 | 270.66 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 105.19 | 156.91 |
Report: PeakSpaceGainsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 2240.79 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.61 | 14-JAN-11:00 | 171.42 | 08-JAN-07:00 |
February | 0.00 | 2240.79 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.28 | 01-FEB-12:00 | 137.84 | 04-FEB-05:55 |
March | 0.00 | 2240.79 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.88 | 11-MAR-11:13 | 146.10 | 08-MAR-02:00 |
April | 0.00 | 2240.79 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.59 | 26-APR-13:00 | 119.21 | 01-APR-06:00 |
May | 0.00 | 2240.79 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.92 | 03-MAY-12:20 | 111.82 | 15-MAY-05:00 |
June | 0.00 | 2240.79 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.84 | 29-JUN-11:00 | 85.31 | 13-JUN-04:20 |
July | 0.00 | 2240.79 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.46 | 19-JUL-12:00 | 67.40 | 06-JUL-01:00 |
August | 0.00 | 2240.79 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.46 | 14-AUG-11:00 | 58.77 | 24-AUG-02:00 |
September | 0.00 | 2240.79 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.11 | 29-SEP-11:00 | 84.71 | 20-SEP-03:05 |
October | 0.00 | 2240.79 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.46 | 16-OCT-11:00 | 102.76 | 30-OCT-04:00 |
November | 0.00 | 2240.79 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.17 | 19-NOV-13:00 | 120.71 | 24-NOV-00:55 |
December | 0.00 | 2240.79 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39.14 | 16-DEC-13:00 | 138.71 | 03-DEC-01:00 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 0.00 | 2240.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.88 | 58.77 | |||
Maximum of Months | 0.00 | 2240.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.46 | 171.42 |
Report: PeakSpaceGainsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 2371.52 | 02-JAN-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.40 | 14-JAN-11:00 | 304.41 | 08-JAN-07:00 |
February | 0.00 | 2371.52 | 01-FEB-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.50 | 01-FEB-12:00 | 245.97 | 04-FEB-06:00 |
March | 0.00 | 2371.52 | 01-MAR-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.52 | 11-MAR-11:00 | 263.15 | 08-MAR-02:00 |
April | 0.00 | 2371.52 | 03-APR-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68.67 | 26-APR-13:00 | 213.56 | 01-APR-06:00 |
May | 0.00 | 2371.52 | 01-MAY-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.71 | 03-MAY-12:00 | 198.82 | 15-MAY-02:00 |
June | 0.00 | 2371.52 | 01-JUN-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.03 | 29-JUN-11:00 | 151.89 | 13-JUN-04:40 |
July | 0.00 | 2371.52 | 03-JUL-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.79 | 19-JUL-11:00 | 124.94 | 06-JUL-01:00 |
August | 0.00 | 2371.52 | 01-AUG-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 82.26 | 14-AUG-11:00 | 110.79 | 28-AUG-07:00 |
September | 0.00 | 2371.52 | 01-SEP-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 182.79 | 29-SEP-11:00 | 150.83 | 20-SEP-03:40 |
October | 0.00 | 2371.52 | 02-OCT-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 190.94 | 16-OCT-11:00 | 182.76 | 30-OCT-04:00 |
November | 0.00 | 2371.52 | 01-NOV-19:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63.19 | 19-NOV-13:00 | 217.06 | 29-NOV-23:00 |
December | 0.00 | 2371.52 | 01-DEC-20:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.01 | 05-DEC-10:00 | 246.61 | 22-DEC-07:00 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 0.00 | 2371.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.71 | 110.79 | |||
Maximum of Months | 0.00 | 2371.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 190.94 | 304.41 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 22827.97 | 08-JAN-07:00 | 8945.92 | 4646.62 | 4258.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 17462.34 | 04-FEB-05:55 | 23003.78 | 3097.75 | 4258.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 18234.99 | 08-MAR-02:00 | 11501.89 | 2323.31 | 2661.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 14646.70 | 26-APR-07:50 | 5111.95 | 6195.49 | 5323.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 14489.83 | 28-MAY-10:00 | 6389.94 | 4646.62 | 4258.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 14562.86 | 29-JUN-18:20 | 17891.83 | 24781.97 | 19162.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 15169.10 | 19-JUL-18:50 | 8945.92 | 12390.98 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 15073.25 | 14-AUG-18:50 | 8945.92 | 12390.98 | 9581.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 16591.48 | 21-SEP-21:10 | 11501.89 | 9293.24 | 7452.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 16451.91 | 16-OCT-19:50 | 8945.92 | 13939.86 | 10113.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 17073.40 | 29-NOV-23:00 | 11501.89 | 9293.24 | 7452.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 18766.97 | 03-DEC-01:00 | 8945.92 | 4646.62 | 4258.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 14489.83 | 5111.95 | 2323.31 | 2661.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22827.97 | 23003.78 | 24781.97 | 19162.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3069.65 | 14-JAN-12:40 | 389.84 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 30.17 | 0.00 |
February | 2492.49 | 02-FEB-12:40 | 259.90 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.75 |
March | 2250.90 | 11-MAR-13:10 | 389.84 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 7.39 | 0.00 |
April | 1992.78 | 08-APR-12:50 | 389.84 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.84 |
May | 1840.72 | 04-MAY-12:40 | 259.90 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 38.40 | 0.00 |
June | 1808.96 | 29-JUN-18:10 | 5457.82 | 3929.72 | 3897.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.10 | 0.00 |
July | 1874.49 | 19-JUL-18:10 | 5457.82 | 3929.72 | 3897.11 | 0.00 | 0.00 | 0.00 | 0.00 | 19.86 | 0.00 |
August | 1951.74 | 27-AUG-12:00 | 389.84 | 245.61 | 288.68 | 0.00 | 0.00 | 0.00 | 0.00 | 18.72 | 0.00 |
September | 2906.15 | 30-SEP-13:10 | 389.84 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 176.05 | 0.00 |
October | 3685.50 | 16-OCT-12:10 | 259.90 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 255.29 | 0.00 |
November | 3369.40 | 19-NOV-12:30 | 389.84 | 245.61 | 288.68 | 0.00 | 0.00 | 0.00 | 0.00 | 56.31 | 0.00 |
December | 3163.85 | 19-DEC-12:50 | 259.90 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 41.44 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1808.96 | 259.90 | 204.67 | 252.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3685.50 | 5457.82 | 3929.72 | 3897.11 | 0.00 | 0.00 | 0.00 | 0.00 | 255.29 | 107.75 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1815.08 | 06-JAN-23:00 | 1354.32 | 568.83 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.56 |
February | 1666.66 | 04-FEB-05:55 | 2708.64 | 189.61 | 334.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.25 |
March | 1685.44 | 08-MAR-01:50 | 1354.32 | 142.21 | 208.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.50 |
April | 1509.33 | 26-APR-20:20 | 1203.84 | 758.44 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.63 |
May | 1528.09 | 04-MAY-21:10 | 1354.32 | 568.83 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.87 |
June | 1553.98 | 29-JUN-18:20 | 2106.72 | 1516.88 | 1504.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.45 |
July | 1612.40 | 19-JUL-19:00 | 1053.36 | 758.44 | 752.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.10 |
August | 1623.02 | 18-AUG-21:10 | 1354.32 | 568.83 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.40 |
September | 1756.10 | 29-SEP-21:10 | 1354.32 | 568.83 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.84 | 0.00 |
October | 1754.71 | 16-OCT-19:50 | 1053.36 | 853.24 | 793.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.73 |
November | 1641.38 | 29-NOV-23:00 | 1354.32 | 568.83 | 585.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.85 |
December | 1674.52 | 03-DEC-01:00 | 1053.36 | 284.41 | 334.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.09 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1509.33 | 1053.36 | 142.21 | 208.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1815.08 | 2708.64 | 1516.88 | 1504.29 | 0.00 | 0.00 | 0.00 | 0.00 | 4.84 | 90.56 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1482.17 | 06-JAN-23:00 | 0.00 | 906.93 | 618.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.61 |
February | 1273.64 | 06-FEB-23:00 | 0.00 | 906.93 | 618.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 162.79 |
March | 1340.05 | 07-MAR-23:00 | 0.00 | 906.93 | 618.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 171.20 |
April | 1277.36 | 26-APR-07:50 | 0.00 | 604.62 | 441.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.15 | 0.00 |
May | 1271.25 | 04-MAY-09:30 | 0.00 | 377.89 | 309.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.32 |
June | 1335.30 | 29-JUN-18:10 | 0.00 | 7255.46 | 4771.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.25 |
July | 1386.32 | 19-JUL-19:00 | 0.00 | 1209.24 | 795.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.37 |
August | 1365.06 | 19-AUG-18:50 | 0.00 | 1058.09 | 706.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.06 |
September | 1455.90 | 29-SEP-21:00 | 0.00 | 1209.24 | 795.27 | 0.00 | 0.00 | 0.00 | 0.00 | 21.17 | 0.00 |
October | 1476.33 | 16-OCT-19:50 | 0.00 | 1360.40 | 839.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.39 |
November | 1329.46 | 29-NOV-23:00 | 0.00 | 906.93 | 618.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 167.21 |
December | 1435.79 | 03-DEC-01:00 | 0.00 | 453.47 | 353.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 179.85 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1271.25 | 0.00 | 377.89 | 309.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1482.17 | 0.00 | 7255.46 | 4771.59 | 0.00 | 0.00 | 0.00 | 0.00 | 21.17 | 185.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 657.52 | 06-JAN-23:00 | 0.00 | 180.44 | 178.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 125.98 |
February | 581.33 | 03-FEB-10:05 | 0.00 | 150.37 | 178.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.91 |
March | 570.49 | 23-MAR-09:50 | 0.00 | 75.18 | 89.22 | 0.00 | 0.00 | 0.00 | 0.00 | 3.46 | 0.00 |
April | 580.93 | 26-APR-07:50 | 0.00 | 120.29 | 127.45 | 0.00 | 0.00 | 0.00 | 0.00 | 1.18 | 0.00 |
May | 585.73 | 04-MAY-09:40 | 0.00 | 75.18 | 89.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.61 | 0.00 |
June | 603.18 | 30-JUN-08:40 | 0.00 | 120.29 | 127.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.13 |
July | 618.13 | 19-JUL-18:50 | 0.00 | 240.58 | 229.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.75 |
August | 611.80 | 19-AUG-18:50 | 0.00 | 210.51 | 203.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.10 |
September | 649.21 | 29-SEP-21:10 | 0.00 | 180.44 | 178.43 | 0.00 | 0.00 | 0.00 | 0.00 | 17.45 | 0.00 |
October | 656.35 | 16-OCT-19:50 | 0.00 | 270.66 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.17 |
November | 597.82 | 19-NOV-13:10 | 0.00 | 60.15 | 76.47 | 0.00 | 0.00 | 0.00 | 0.00 | 37.73 | 0.00 |
December | 604.30 | 03-DEC-00:25 | 0.00 | 180.44 | 203.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.88 |
Annual Sum or Average | |||||||||||
Minimum of Months | 570.49 | 0.00 | 60.15 | 76.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 657.52 | 0.00 | 270.66 | 242.16 | 0.00 | 0.00 | 0.00 | 0.00 | 37.73 | 125.98 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 37266.84 | 24-JAN-21:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 105.56 |
February | 37081.08 | 17-FEB-21:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 152.51 |
March | 37422.73 | 23-MAR-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 151.73 |
April | 37579.03 | 26-APR-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 105.14 |
May | 37581.90 | 04-MAY-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 105.25 |
June | 37560.55 | 30-JUN-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 120.48 |
July | 37764.96 | 19-JUL-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 74.58 |
August | 37712.24 | 18-AUG-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 74.64 |
September | 38066.93 | 29-SEP-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 14.53 | 0.00 |
October | 37973.14 | 16-OCT-20:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 44.39 |
November | 37230.25 | 20-NOV-21:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 151.88 |
December | 37354.96 | 05-DEC-21:00 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 121.01 |
Annual Sum or Average | |||||||||||
Minimum of Months | 37081.08 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 38066.93 | 705.60 | 408.24 | 4572.80 | 39726.58 | 0.00 | 0.00 | 0.00 | 14.53 | 152.51 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 12187.34 | 14-JAN-12:40 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 76.22 | 0.00 |
February | 9920.14 | 04-FEB-12:30 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.00 |
March | 9765.34 | 11-MAR-13:10 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 21.75 | 0.00 |
April | 8801.49 | 08-APR-12:30 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.23 |
May | 8668.57 | 04-MAY-21:30 | 15368.40 | 1174.61 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 373.38 |
June | 8569.54 | 27-JUN-22:00 | 15368.40 | 1174.61 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 366.21 |
July | 8962.37 | 31-JUL-21:30 | 15368.40 | 1174.61 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 254.36 |
August | 9088.45 | 18-AUG-21:30 | 15368.40 | 1174.61 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 251.56 |
September | 10902.73 | 30-SEP-12:00 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 444.89 | 0.00 |
October | 12873.35 | 15-OCT-12:00 | 5122.80 | 358.25 | 406.43 | 0.00 | 0.00 | 0.00 | 0.00 | 447.00 | 0.00 |
November | 13362.05 | 19-NOV-11:00 | 8538.00 | 358.25 | 406.43 | 0.00 | 0.00 | 0.00 | 0.00 | 114.07 | 0.00 |
December | 12113.54 | 16-DEC-13:00 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 114.66 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 8569.54 | 5122.80 | 298.55 | 355.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13362.05 | 15368.40 | 1174.61 | 711.25 | 0.00 | 0.00 | 0.00 | 0.00 | 447.00 | 373.38 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 37274.65 | 03-JAN-01:55 | 91245.96 | 4030.04 | 5278.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2275.84 |
February | 34483.98 | 04-FEB-05:55 | 91245.96 | 2686.69 | 4222.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2116.73 |
March | 34765.60 | 08-MAR-02:00 | 45622.98 | 2015.02 | 2639.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2147.18 |
April | 30327.50 | 26-APR-22:00 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 887.35 |
May | 31132.23 | 04-MAY-21:10 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 761.65 |
June | 30973.80 | 28-JUN-21:10 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 754.43 |
July | 32239.98 | 31-JUL-21:10 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 512.74 |
August | 32530.01 | 18-AUG-22:00 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 521.13 |
September | 35069.11 | 29-SEP-21:10 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 90.58 | 0.00 |
October | 34654.90 | 16-OCT-22:00 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 458.42 |
November | 33392.28 | 29-NOV-23:00 | 45622.98 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2011.75 |
December | 33680.80 | 23-DEC-04:00 | 45622.98 | 1343.35 | 2111.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2077.04 |
Annual Sum or Average | |||||||||||
Minimum of Months | 30327.50 | 45622.98 | 1343.35 | 2111.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 37274.65 | 91245.96 | 8060.08 | 7389.94 | 0.00 | 0.00 | 0.00 | 0.00 | 90.58 | 2275.84 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2647.50 | 14-JAN-16:01 | 378.00 | 62.19 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 2.07 | 0.00 |
February | 2603.64 | 03-FEB-16:01 | 680.40 | 79.60 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.30 |
March | 2652.86 | 11-MAR-16:01 | 378.00 | 62.19 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.96 |
April | 2618.48 | 01-APR-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 1.58 | 0.00 |
May | 2491.39 | 24-MAY-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.74 |
June | 2492.48 | 20-JUN-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.88 |
July | 2575.92 | 19-JUL-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 25.58 | 0.00 |
August | 2599.41 | 19-AUG-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 20.15 | 0.00 |
September | 2556.85 | 11-SEP-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.06 |
October | 2794.85 | 15-OCT-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 51.90 | 0.00 |
November | 2602.86 | 19-NOV-09:02 | 324.00 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 12.88 | 0.00 |
December | 2657.93 | 05-DEC-16:01 | 680.40 | 79.60 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.48 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2491.39 | 324.00 | 53.30 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2794.85 | 680.40 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 51.90 | 15.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2557.64 | 14-JAN-16:01 | 378.00 | 62.18 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 2.98 | 0.00 |
February | 2520.68 | 03-FEB-16:01 | 680.40 | 79.59 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.66 |
March | 2576.57 | 11-MAR-16:01 | 378.00 | 62.18 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.51 |
April | 2547.27 | 01-APR-15:02 | 324.00 | 53.30 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1.92 | 0.00 |
May | 2447.61 | 03-MAY-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.18 |
June | 2442.55 | 20-JUN-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.98 |
July | 2521.72 | 19-JUL-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 25.48 | 0.00 |
August | 2516.17 | 19-AUG-15:02 | 324.00 | 53.30 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 20.12 | 0.00 |
September | 2440.08 | 30-SEP-18:02 | 702.00 | 852.73 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.53 | 0.00 |
October | 2708.78 | 16-OCT-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 46.07 | 0.00 |
November | 2433.17 | 27-NOV-16:01 | 680.40 | 79.59 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.48 |
December | 2575.56 | 05-DEC-16:01 | 680.40 | 79.59 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.11 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2433.17 | 324.00 | 53.30 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2708.78 | 702.00 | 852.73 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 46.07 | 18.48 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 597.75 | 14-JAN-12:40 | 0.00 | 5.58 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 3.64 | 0.00 |
February | 537.83 | 02-FEB-12:30 | 0.00 | 5.58 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.34 |
March | 399.63 | 11-MAR-13:10 | 0.00 | 5.58 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 1.16 | 0.00 |
April | 273.26 | 08-APR-12:40 | 0.00 | 5.58 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.97 |
May | 164.80 | 04-MAY-13:30 | 0.00 | 5.58 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.71 |
June | 137.21 | 29-JUN-17:50 | 0.00 | 60.30 | 131.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 |
July | 229.65 | 31-JUL-17:13 | 0.00 | 180.89 | 394.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.54 | 0.00 |
August | 284.29 | 18-AUG-15:02 | 0.00 | 42.88 | 402.47 | 0.00 | 0.00 | 0.00 | 0.00 | 5.78 | 0.00 |
September | 542.25 | 30-SEP-13:00 | 0.00 | 5.58 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 15.57 | 0.00 |
October | 675.94 | 16-OCT-12:10 | 0.00 | 5.58 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 22.06 | 0.00 |
November | 637.16 | 19-NOV-12:30 | 0.00 | 5.58 | 74.82 | 0.00 | 0.00 | 0.00 | 0.00 | 5.77 | 0.00 |
December | 608.90 | 19-DEC-13:00 | 0.00 | 5.58 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 4.86 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 137.21 | 0.00 | 5.58 | 67.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 675.94 | 0.00 | 180.89 | 402.47 | 0.00 | 0.00 | 0.00 | 0.00 | 22.06 | 7.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 816.12 | 15-JAN-09:02 | 270.00 | 104.25 | 799.99 | 0.00 | 0.00 | 0.00 | 0.00 | 1.40 | 0.00 |
February | 741.35 | 01-FEB-09:02 | 216.00 | 234.55 | 665.80 | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 0.00 |
March | 786.50 | 11-MAR-09:02 | 324.00 | 125.09 | 959.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.92 |
April | 789.73 | 01-APR-15:02 | 324.00 | 33.51 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 3.07 | 0.00 |
May | 783.92 | 04-MAY-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 | 0.00 |
June | 781.97 | 30-JUN-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 2.07 | 0.00 |
July | 813.08 | 19-JUL-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 8.30 | 0.00 |
August | 805.76 | 19-AUG-15:02 | 324.00 | 33.51 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 6.91 | 0.00 |
September | 828.76 | 30-SEP-18:02 | 702.00 | 536.12 | 758.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.58 | 0.00 |
October | 901.72 | 15-OCT-08:62 | 324.00 | 125.09 | 959.99 | 0.00 | 0.00 | 0.00 | 0.00 | 13.10 | 0.00 |
November | 846.53 | 19-NOV-09:02 | 324.00 | 125.09 | 959.99 | 0.00 | 0.00 | 0.00 | 0.00 | 4.44 | 0.00 |
December | 819.35 | 05-DEC-09:02 | 216.00 | 234.55 | 665.80 | 0.00 | 0.00 | 0.00 | 0.00 | 5.22 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 741.35 | 216.00 | 33.51 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 901.72 | 702.00 | 536.12 | 959.99 | 0.00 | 0.00 | 0.00 | 0.00 | 13.10 | 1.92 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2320.84 | 14-JAN-16:01 | 378.00 | 62.19 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 2.02 | 0.00 |
February | 2274.87 | 01-FEB-09:02 | 216.00 | 373.11 | 679.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 |
March | 2300.47 | 11-MAR-16:01 | 378.00 | 62.19 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.35 |
April | 2254.87 | 01-APR-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 3.22 | 0.00 |
May | 2192.80 | 24-MAY-08:62 | 216.00 | 373.11 | 679.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.34 |
June | 2131.02 | 21-JUN-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 |
July | 2177.32 | 23-JUL-08:62 | 324.00 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 3.06 | 0.00 |
August | 2179.64 | 19-AUG-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 20.38 | 0.00 |
September | 2211.90 | 30-SEP-18:02 | 702.00 | 852.83 | 774.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
October | 2442.48 | 15-OCT-08:62 | 324.00 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 44.60 | 0.00 |
November | 2368.28 | 19-NOV-09:02 | 324.00 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 0.00 |
December | 2355.92 | 05-DEC-09:02 | 216.00 | 373.11 | 679.57 | 0.00 | 0.00 | 0.00 | 0.00 | 10.61 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2131.02 | 216.00 | 53.30 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2442.48 | 702.00 | 852.83 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 44.60 | 32.34 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2080.44 | 14-JAN-16:01 | 378.00 | 62.18 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 11.14 | 0.00 |
February | 2154.49 | 01-FEB-09:02 | 216.00 | 373.07 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 2.61 | 0.00 |
March | 2136.04 | 11-MAR-16:01 | 378.00 | 62.18 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.40 |
April | 2182.57 | 26-APR-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 1.12 | 0.00 |
May | 2174.66 | 24-MAY-08:62 | 216.00 | 373.07 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.39 |
June | 2110.00 | 21-JUN-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.58 |
July | 2158.36 | 23-JUL-08:62 | 324.00 | 198.97 | 979.73 | 0.00 | 0.00 | 0.00 | 0.00 | 3.00 | 0.00 |
August | 2140.82 | 19-AUG-18:02 | 702.00 | 852.73 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.59 | 0.00 |
September | 2171.07 | 30-SEP-18:02 | 702.00 | 852.73 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 | 0.00 |
October | 2406.66 | 15-OCT-08:62 | 324.00 | 198.97 | 979.73 | 0.00 | 0.00 | 0.00 | 0.00 | 44.96 | 0.00 |
November | 2314.79 | 19-NOV-09:02 | 324.00 | 198.97 | 979.73 | 0.00 | 0.00 | 0.00 | 0.00 | 11.18 | 0.00 |
December | 2305.38 | 05-DEC-09:02 | 216.00 | 373.07 | 679.49 | 0.00 | 0.00 | 0.00 | 0.00 | 11.41 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2080.44 | 216.00 | 62.18 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2406.66 | 702.00 | 852.73 | 979.73 | 0.00 | 0.00 | 0.00 | 0.00 | 44.96 | 32.39 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1756.01 | 20-JAN-12:00 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.82 | 0.00 |
February | 1736.88 | 01-FEB-13:20 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.70 | 0.00 |
March | 1731.34 | 11-MAR-14:10 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.64 | 0.00 |
April | 1717.39 | 26-APR-17:13 | 0.00 | 4481.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.37 |
May | 1719.37 | 04-MAY-14:00 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.86 | 0.00 |
June | 1744.38 | 29-JUN-18:07 | 0.00 | 11950.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.09 | 0.00 |
July | 1764.51 | 19-JUL-18:50 | 0.00 | 1991.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.89 | 0.00 |
August | 1754.18 | 19-AUG-18:30 | 0.00 | 1742.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.71 | 0.00 |
September | 1830.27 | 30-SEP-14:40 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81.60 | 0.00 |
October | 1859.96 | 16-OCT-13:50 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.26 | 0.00 |
November | 1784.00 | 19-NOV-13:10 | 0.00 | 497.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.57 | 0.00 |
December | 1763.02 | 19-DEC-14:10 | 0.00 | 622.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.37 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1717.39 | 0.00 | 497.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1859.96 | 0.00 | 11950.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.26 | 0.37 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2737.56 | 14-JAN-16:01 | 378.00 | 62.19 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 1.47 | 0.00 |
February | 2689.03 | 03-FEB-16:01 | 680.40 | 79.60 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.83 |
March | 2744.73 | 11-MAR-16:01 | 378.00 | 62.19 | 534.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.60 |
April | 2707.06 | 01-APR-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 0.00 |
May | 2581.23 | 17-MAY-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.48 |
June | 2657.98 | 30-JUN-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.68 | 0.00 |
July | 2758.01 | 19-JUL-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 24.91 | 0.00 |
August | 2744.89 | 18-AUG-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 23.76 | 0.00 |
September | 2617.74 | 13-SEP-15:02 | 583.20 | 68.23 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.40 |
October | 2898.52 | 15-OCT-15:02 | 324.00 | 53.30 | 458.31 | 0.00 | 0.00 | 0.00 | 0.00 | 51.14 | 0.00 |
November | 2648.15 | 19-NOV-09:02 | 324.00 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 13.62 | 0.00 |
December | 2749.38 | 05-DEC-16:01 | 680.40 | 79.60 | 479.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.10 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2581.23 | 324.00 | 53.30 | 410.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2898.52 | 680.40 | 198.99 | 979.84 | 0.00 | 0.00 | 0.00 | 0.00 | 51.14 | 15.83 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2647.97 | 14-JAN-16:01 | 378.00 | 62.18 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 2.17 | 0.00 |
February | 2598.52 | 03-FEB-16:01 | 680.40 | 79.59 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.07 |
March | 2663.61 | 11-MAR-16:01 | 378.00 | 62.18 | 534.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.10 |
April | 2628.80 | 01-APR-15:02 | 324.00 | 53.30 | 458.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1.45 | 0.00 |
May | 2550.94 | 02-MAY-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.77 |
June | 2602.99 | 30-JUN-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.56 | 0.00 |
July | 2704.33 | 19-JUL-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 24.80 | 0.00 |
August | 2712.13 | 17-AUG-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 23.26 | 0.00 |
September | 2550.17 | 30-SEP-18:02 | 702.00 | 852.73 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.08 | 0.00 |
October | 2807.29 | 16-OCT-15:02 | 583.20 | 68.22 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 45.35 | 0.00 |
November | 2529.46 | 27-NOV-16:01 | 680.40 | 79.59 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.79 |
December | 2658.74 | 05-DEC-16:01 | 680.40 | 79.59 | 479.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2529.46 | 324.00 | 53.30 | 410.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 2807.29 | 702.00 | 852.73 | 774.30 | 0.00 | 0.00 | 0.00 | 0.00 | 45.35 | 19.79 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1402.54 | 14-JAN-16:01 | 378.00 | 39.09 | 523.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.07 |
February | 1367.25 | 03-FEB-16:01 | 680.40 | 50.04 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 |
March | 1380.35 | 10-MAR-16:01 | 680.40 | 50.04 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.45 |
April | 1370.69 | 01-APR-15:02 | 324.00 | 33.51 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.09 | 0.00 |
May | 1312.11 | 03-MAY-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.38 |
June | 1265.08 | 30-JUN-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 0.00 |
July | 1292.68 | 19-JUL-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 12.69 | 0.00 |
August | 1325.48 | 19-AUG-15:02 | 324.00 | 33.51 | 449.03 | 0.00 | 0.00 | 0.00 | 0.00 | 9.92 | 0.00 |
September | 1326.51 | 11-SEP-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.02 |
October | 1461.68 | 16-OCT-15:02 | 583.20 | 42.89 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 22.53 | 0.00 |
November | 1407.17 | 19-NOV-09:02 | 324.00 | 125.09 | 959.99 | 0.00 | 0.00 | 0.00 | 0.00 | 4.73 | 0.00 |
December | 1403.11 | 05-DEC-16:01 | 680.40 | 50.04 | 469.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.26 |
Annual Sum or Average | |||||||||||
Minimum of Months | 1265.08 | 324.00 | 33.51 | 402.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1461.68 | 680.40 | 125.09 | 959.99 | 0.00 | 0.00 | 0.00 | 0.00 | 22.53 | 8.67 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 18835.07 | 09-JAN-05:55 | 53977.54 | 1375.14 | 4498.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 348.00 |
February | 18450.60 | 15-FEB-23:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.27 |
March | 18726.67 | 24-MAR-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.54 |
April | 19300.05 | 26-APR-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.93 |
May | 19661.11 | 04-MAY-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.71 |
June | 19842.93 | 27-JUN-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.52 |
July | 20043.98 | 19-JUL-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.48 |
August | 19911.67 | 18-AUG-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.63 |
September | 20428.82 | 29-SEP-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 6.53 | 0.00 |
October | 20134.99 | 16-OCT-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.67 |
November | 18525.64 | 01-NOV-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.53 |
December | 18681.37 | 05-DEC-23:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.99 |
Annual Sum or Average | |||||||||||
Minimum of Months | 18450.60 | 26988.77 | 1375.14 | 4498.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20428.82 | 53977.54 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 6.53 | 348.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 20333.69 | 18-JAN-22:10 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 122.26 |
February | 20349.63 | 15-FEB-23:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 189.27 |
March | 20535.91 | 24-MAR-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 187.54 |
April | 21109.44 | 26-APR-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.93 |
May | 21418.59 | 04-MAY-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.72 |
June | 21592.77 | 27-JUN-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.52 |
July | 21772.03 | 19-JUL-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.49 |
August | 21596.83 | 18-AUG-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.64 |
September | 22120.83 | 29-SEP-21:10 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 7.87 | 0.00 |
October | 21713.80 | 16-OCT-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.67 |
November | 20316.77 | 01-NOV-22:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 170.54 |
December | 20487.38 | 05-DEC-23:00 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 101.99 |
Annual Sum or Average | |||||||||||
Minimum of Months | 20316.77 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 22120.83 | 26988.77 | 2062.71 | 6747.90 | 0.00 | 0.00 | 0.00 | 0.00 | 7.87 | 189.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 28443.84 | 14-JAN-11:50 | 800.57 | 302.73 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 27.81 | 0.00 |
February | 28120.51 | 01-FEB-11:50 | 1067.42 | 605.46 | 29825.71 | 37488.05 | 0.00 | 0.00 | 0.00 | 20.43 | 0.00 |
March | 28895.85 | 12-MAR-10:40 | 800.57 | 363.28 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 40.68 |
April | 29184.96 | 30-APR-10:50 | 800.57 | 363.28 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 25.35 | 0.00 |
May | 28777.79 | 02-MAY-10:40 | 533.71 | 302.73 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 35.67 |
June | 29039.32 | 25-JUN-10:40 | 800.57 | 363.28 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 15.96 |
July | 29395.20 | 23-JUL-10:50 | 800.57 | 363.28 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 25.43 | 0.00 |
August | 29258.81 | 15-AUG-10:40 | 533.71 | 302.73 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 42.12 | 0.00 |
September | 29782.48 | 30-SEP-10:40 | 1601.14 | 605.46 | 29825.71 | 37488.05 | 0.00 | 0.00 | 0.00 | 92.24 | 0.00 |
October | 29820.37 | 15-OCT-10:40 | 1601.14 | 726.55 | 29825.71 | 37488.05 | 0.00 | 0.00 | 0.00 | 108.03 | 0.00 |
November | 28955.13 | 19-NOV-11:50 | 800.57 | 363.28 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 27.73 | 0.00 |
December | 28217.47 | 17-DEC-11:50 | 1601.14 | 726.55 | 29825.71 | 37488.05 | 0.00 | 0.00 | 0.00 | 0.00 | 20.97 |
Annual Sum or Average | |||||||||||
Minimum of Months | 28120.51 | 533.71 | 302.73 | 14912.86 | 18744.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 29820.37 | 1601.14 | 726.55 | 29825.71 | 37488.05 | 0.00 | 0.00 | 0.00 | 108.03 | 40.68 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3598.74 | 14-JAN-14:20 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.68 | 0.00 |
February | 3534.64 | 01-FEB-13:10 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.07 | 0.00 |
March | 3595.93 | 11-MAR-13:20 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.67 | 0.00 |
April | 3602.44 | 26-APR-13:50 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.59 | 0.00 |
May | 3639.47 | 04-MAY-12:30 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.64 | 0.00 |
June | 3638.24 | 30-JUN-13:50 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.56 | 0.00 |
July | 3741.54 | 30-JUL-13:40 | 0.00 | 527.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.00 | 0.00 |
August | 3757.52 | 19-AUG-14:00 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.73 | 0.00 |
September | 4031.64 | 30-SEP-14:00 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.23 | 0.00 |
October | 4056.92 | 16-OCT-13:20 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.37 | 0.00 |
November | 3731.24 | 19-NOV-13:10 | 0.00 | 527.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.50 | 0.00 |
December | 3657.08 | 19-DEC-13:20 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.89 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3534.64 | 0.00 | 527.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.56 | 0.00 | |
Maximum of Months | 4056.92 | 0.00 | 658.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.37 | 0.00 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.431182E+12 | 302640.00 | 17-JAN-20:10 | 0.485502E+12 | 418589.45 | 11-JAN-18:40 |
February | 0.378656E+12 | 285333.39 | 13-FEB-20:30 | 0.423732E+12 | 389018.18 | 27-FEB-18:49 |
March | 0.412356E+12 | 275116.18 | 22-MAR-18:10 | 0.498714E+12 | 417432.93 | 06-MAR-18:19 |
April | 0.426930E+12 | 305705.56 | 26-APR-19:10 | 0.393791E+12 | 358990.48 | 15-APR-21:30 |
May | 0.443482E+12 | 305013.66 | 04-MAY-19:10 | 0.395890E+12 | 365799.32 | 10-MAY-19:49 |
June | 0.472753E+12 | 322768.38 | 29-JUN-19:10 | 0.335106E+12 | 308922.20 | 12-JUN-20:49 |
July | 0.554088E+12 | 354740.86 | 31-JUL-19:10 | 0.335413E+12 | 278086.02 | 12-JUL-17:10 |
August | 0.570407E+12 | 347440.27 | 14-AUG-19:10 | 0.334244E+12 | 277725.25 | 29-AUG-17:19 |
September | 0.502262E+12 | 367340.34 | 29-SEP-19:10 | 0.327884E+12 | 279335.94 | 21-SEP-17:19 |
October | 0.520504E+12 | 356602.19 | 04-OCT-19:49 | 0.357819E+12 | 308450.42 | 11-OCT-20:49 |
November | 0.423804E+12 | 286196.37 | 10-NOV-20:00 | 0.421447E+12 | 380977.70 | 16-NOV-20:30 |
December | 0.435491E+12 | 297877.07 | 05-DEC-20:10 | 0.480957E+12 | 416338.55 | 13-DEC-18:30 |
Annual Sum or Average | 0.557192E+13 | 0.479050E+13 | ||||
Minimum of Months | 0.378656E+12 | 275116.18 | 0.327884E+12 | 277725.25 | ||
Maximum of Months | 0.570407E+12 | 367340.34 | 0.498714E+12 | 418589.45 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.654371E+11 | 0.223450E+11 | 0.148212E+12 | 0.834801E+11 | 0.478181E+11 | 0.902974E+10 | 0.00 | 0.419378E+11 | 0.00 | 0.00 | 0.00 | 0.770555E+10 | 0.00 |
February | 0.589954E+11 | 0.190997E+11 | 0.133859E+12 | 0.754015E+11 | 0.433648E+11 | 0.770921E+10 | 0.00 | 0.285268E+11 | 0.00 | 0.00 | 0.00 | 0.696270E+10 | 0.00 |
March | 0.653950E+11 | 0.195756E+11 | 0.148234E+12 | 0.834832E+11 | 0.476923E+11 | 0.788724E+10 | 0.00 | 0.271267E+11 | 0.00 | 0.00 | 0.00 | 0.770531E+10 | 0.00 |
April | 0.629272E+11 | 0.174035E+11 | 0.143397E+12 | 0.807867E+11 | 0.461176E+11 | 0.976062E+10 | 0.00 | 0.539626E+11 | 0.00 | 0.00 | 0.00 | 0.746568E+10 | 0.00 |
May | 0.650143E+11 | 0.166159E+11 | 0.148223E+12 | 0.834813E+11 | 0.474842E+11 | 0.104821E+11 | 0.00 | 0.591898E+11 | 0.00 | 0.00 | 0.00 | 0.770516E+10 | 0.00 |
June | 0.629187E+11 | 0.154044E+11 | 0.143446E+12 | 0.807895E+11 | 0.456613E+11 | 0.119753E+11 | 0.00 | 0.999638E+11 | 0.00 | 0.00 | 0.00 | 0.745794E+10 | 0.00 |
July | 0.648326E+11 | 0.162178E+11 | 0.148174E+12 | 0.834784E+11 | 0.472264E+11 | 0.145802E+11 | 0.00 | 0.166589E+12 | 0.00 | 0.00 | 0.00 | 0.771359E+10 | 0.00 |
August | 0.651517E+11 | 0.173688E+11 | 0.148234E+12 | 0.834830E+11 | 0.473112E+11 | 0.150400E+11 | 0.00 | 0.180812E+12 | 0.00 | 0.00 | 0.00 | 0.770544E+10 | 0.00 |
September | 0.630690E+11 | 0.182862E+11 | 0.143397E+12 | 0.807869E+11 | 0.455707E+11 | 0.128662E+11 | 0.00 | 0.125691E+12 | 0.00 | 0.00 | 0.00 | 0.746619E+10 | 0.00 |
October | 0.653640E+11 | 0.204930E+11 | 0.148212E+12 | 0.834801E+11 | 0.476492E+11 | 0.129194E+11 | 0.00 | 0.129426E+12 | 0.00 | 0.00 | 0.00 | 0.770533E+10 | 0.00 |
November | 0.633732E+11 | 0.212286E+11 | 0.143462E+12 | 0.807881E+11 | 0.467794E+11 | 0.937936E+10 | 0.00 | 0.462797E+11 | 0.00 | 0.00 | 0.00 | 0.744976E+10 | 0.00 |
December | 0.653256E+11 | 0.227257E+11 | 0.148174E+12 | 0.834788E+11 | 0.481461E+11 | 0.910904E+10 | 0.00 | 0.456203E+11 | 0.00 | 0.00 | 0.00 | 0.771355E+10 | 0.00 |
Annual Sum or Average | 0.767804E+12 | 0.226764E+12 | 0.174502E+13 | 0.982918E+12 | 0.560821E+12 | 0.130738E+12 | 0.00 | 0.100513E+13 | 0.907562E+11 | ||||
Minimum of Months | 0.589954E+11 | 0.154044E+11 | 0.133859E+12 | 0.754015E+11 | 0.433648E+11 | 0.770921E+10 | 0.00 | 0.271267E+11 | 0.00 | 0.00 | 0.00 | 0.696270E+10 | 0.00 |
Maximum of Months | 0.654371E+11 | 0.227257E+11 | 0.148234E+12 | 0.834832E+11 | 0.481461E+11 | 0.150400E+11 | 0.00 | 0.180812E+12 | 0.00 | 0.00 | 0.00 | 0.771359E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportINTERIOREQUIPMENT:GAS [J] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.151918E+12 | 0.00 | 0.156792E+12 | 0.00 | 0.176791E+12 | 0.00 | 0.00 |
February | 0.137204E+12 | 0.00 | 0.126434E+12 | 0.00 | 0.160094E+12 | 0.00 | 0.00 |
March | 0.152039E+12 | 0.00 | 0.169965E+12 | 0.00 | 0.176710E+12 | 0.00 | 0.00 |
April | 0.146956E+12 | 0.00 | 0.779624E+11 | 0.00 | 0.168873E+12 | 0.00 | 0.00 |
May | 0.151978E+12 | 0.00 | 0.715442E+11 | 0.00 | 0.172367E+12 | 0.00 | 0.00 |
June | 0.147114E+12 | 0.00 | 0.230500E+11 | 0.00 | 0.164942E+12 | 0.00 | 0.00 |
July | 0.151820E+12 | 0.00 | 0.144873E+11 | 0.00 | 0.169106E+12 | 0.00 | 0.00 |
August | 0.152039E+12 | 0.00 | 0.131432E+11 | 0.00 | 0.169062E+12 | 0.00 | 0.00 |
September | 0.146956E+12 | 0.00 | 0.164010E+11 | 0.00 | 0.164527E+12 | 0.00 | 0.00 |
October | 0.151918E+12 | 0.00 | 0.340714E+11 | 0.00 | 0.171829E+12 | 0.00 | 0.00 |
November | 0.147091E+12 | 0.00 | 0.106289E+12 | 0.00 | 0.168067E+12 | 0.00 | 0.00 |
December | 0.151820E+12 | 0.00 | 0.153200E+12 | 0.00 | 0.175937E+12 | 0.00 | 0.00 |
Annual Sum or Average | 0.178885E+13 | 0.963340E+12 | 0.203830E+13 | ||||
Minimum of Months | 0.137204E+12 | 0.00 | 0.131432E+11 | 0.00 | 0.160094E+12 | 0.00 | 0.00 |
Maximum of Months | 0.152039E+12 | 0.00 | 0.169965E+12 | 0.00 | 0.176791E+12 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum}[W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 66976.13 | 02-JAN-20:10 | 14423.55 | 01-JAN-00:10 | 89475.41 | 02-JAN-07:10 | 63148.16 | 18-JAN-07:19 | 25263.73 | 05-JAN-21:40 | 6213.30 | 24-JAN-10:09 | 0.00 | 01-JAN-00:10 |
February | 66976.13 | 01-FEB-20:10 | 14423.55 | 01-FEB-00:10 | 89475.41 | 01-FEB-07:10 | 63147.73 | 10-FEB-07:19 | 26465.09 | 02-FEB-21:19 | 6028.03 | 01-FEB-13:09 | 0.00 | 01-FEB-00:10 |
March | 66976.13 | 01-MAR-20:10 | 14423.55 | 01-MAR-00:10 | 89475.41 | 01-MAR-07:10 | 63148.16 | 13-MAR-06:19 | 25788.27 | 22-MAR-20:00 | 6151.04 | 23-MAR-15:09 | 0.00 | 01-MAR-00:10 |
April | 66976.13 | 03-APR-19:10 | 14423.55 | 01-APR-00:10 | 89475.41 | 03-APR-06:10 | 63147.54 | 05-APR-06:19 | 25701.78 | 06-APR-20:30 | 6048.04 | 03-APR-09:39 | 0.00 | 01-APR-00:10 |
May | 66976.13 | 01-MAY-19:10 | 14423.55 | 01-MAY-00:10 | 89475.41 | 01-MAY-06:10 | 63147.11 | 08-MAY-06:19 | 25804.77 | 10-MAY-20:19 | 6199.47 | 18-MAY-15:09 | 0.00 | 01-MAY-00:10 |
June | 66976.13 | 01-JUN-19:10 | 14423.55 | 01-JUN-00:10 | 89475.41 | 01-JUN-06:10 | 63147.11 | 09-JUN-06:19 | 25636.54 | 12-JUN-20:00 | 6302.08 | 29-JUN-18:10 | 0.00 | 01-JUN-00:10 |
July | 66976.13 | 03-JUL-19:10 | 14423.55 | 01-JUL-00:10 | 89475.41 | 03-JUL-06:10 | 63147.11 | 11-JUL-06:19 | 24395.58 | 07-JUL-20:00 | 6418.40 | 24-JUL-18:10 | 0.00 | 01-JUL-00:10 |
August | 66976.13 | 01-AUG-19:10 | 14423.55 | 01-AUG-00:10 | 89475.41 | 01-AUG-06:10 | 63147.54 | 21-AUG-06:19 | 24456.51 | 21-AUG-20:00 | 6467.82 | 13-AUG-16:30 | 0.00 | 01-AUG-00:10 |
September | 66976.13 | 01-SEP-19:10 | 14423.55 | 01-SEP-00:10 | 89475.41 | 01-SEP-06:10 | 63148.16 | 18-SEP-06:19 | 24740.54 | 18-SEP-20:00 | 6680.13 | 29-SEP-15:20 | 0.00 | 01-SEP-00:10 |
October | 66976.13 | 02-OCT-19:10 | 14423.55 | 01-OCT-00:10 | 89475.41 | 02-OCT-06:10 | 63148.16 | 05-OCT-06:19 | 25406.50 | 11-OCT-20:00 | 6490.18 | 01-OCT-15:30 | 0.00 | 01-OCT-00:10 |
November | 66976.13 | 01-NOV-19:10 | 14423.55 | 01-NOV-00:10 | 89475.41 | 01-NOV-06:10 | 63148.16 | 01-NOV-06:19 | 26321.65 | 29-NOV-21:00 | 6312.68 | 19-NOV-10:00 | 0.00 | 01-NOV-00:10 |
December | 66976.13 | 01-DEC-20:10 | 14423.55 | 01-DEC-00:10 | 89475.41 | 01-DEC-07:10 | 63148.16 | 08-DEC-07:19 | 25805.97 | 20-DEC-21:19 | 6088.85 | 16-DEC-16:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 66976.13 | 14423.55 | 89475.41 | 63147.11 | 24395.58 | 6028.03 | 0.00 | |||||||
Maximum of Months | 66976.13 | 14423.55 | 89475.41 | 63148.16 | 26465.09 | 6680.13 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 85484.42 | 14-JAN-10:00 | 0.00 | 0.00 | 0.00 | 4739.12 | 09-JAN-07:30 | 0.00 |
February | 81590.00 | 01-FEB-11:00 | 0.00 | 0.00 | 0.00 | 4738.29 | 01-FEB-19:10 | 0.00 |
March | 82656.35 | 23-MAR-15:09 | 0.00 | 0.00 | 0.00 | 4739.51 | 30-MAR-06:10 | 0.00 |
April | 88901.83 | 26-APR-10:00 | 0.00 | 0.00 | 0.00 | 4738.27 | 19-APR-18:10 | 0.00 |
May | 73427.16 | 04-MAY-15:09 | 0.00 | 0.00 | 0.00 | 4738.51 | 24-MAY-18:10 | 0.00 |
June | 102157.69 | 29-JUN-10:00 | 0.00 | 0.00 | 0.00 | 4738.31 | 20-JUN-06:19 | 0.00 |
July | 143203.43 | 19-JUL-15:09 | 0.00 | 0.00 | 0.00 | 4737.71 | 17-JUL-06:00 | 0.00 |
August | 150945.66 | 18-AUG-15:09 | 0.00 | 0.00 | 0.00 | 4738.21 | 24-AUG-18:19 | 0.00 |
September | 164736.38 | 29-SEP-12:00 | 0.00 | 0.00 | 0.00 | 4738.19 | 07-SEP-18:10 | 0.00 |
October | 182724.56 | 16-OCT-10:00 | 0.00 | 0.00 | 0.00 | 4738.12 | 12-OCT-18:10 | 0.00 |
November | 93346.22 | 19-NOV-10:00 | 0.00 | 0.00 | 0.00 | 4738.40 | 01-NOV-18:10 | 0.00 |
December | 86832.10 | 05-DEC-09:00 | 0.00 | 0.00 | 0.00 | 4738.37 | 18-DEC-19:10 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 73427.16 | 0.00 | 0.00 | 0.00 | 4737.71 | 0.00 | ||
Maximum of Months | 182724.56 | 0.00 | 0.00 | 0.00 | 4739.51 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 302640.00 | 17-JAN-20:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 19797.55 | 5333.04 | 0.00 | 50593.84 | 0.00 |
February | 285333.39 | 13-FEB-20:30 | 66976.13 | 88772.42 | 14423.55 | 50900.13 | 22055.14 | 4467.84 | 0.00 | 31389.11 | 0.00 |
March | 275116.18 | 22-MAR-18:10 | 59510.80 | 79417.81 | 14423.55 | 50575.94 | 22672.82 | 4719.24 | 0.00 | 36816.46 | 0.00 |
April | 305705.56 | 26-APR-19:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 22692.79 | 5513.40 | 0.00 | 50335.69 | 0.00 |
May | 305013.66 | 04-MAY-19:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 22336.40 | 5466.85 | 0.00 | 50005.84 | 0.00 |
June | 322768.38 | 29-JUN-19:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 22572.99 | 6002.45 | 0.00 | 66804.16 | 0.00 |
July | 354740.86 | 31-JUL-19:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 22409.69 | 6349.31 | 0.00 | 98768.98 | 0.00 |
August | 347440.27 | 14-AUG-19:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 22261.42 | 6286.56 | 0.00 | 91690.25 | 0.00 |
September | 367340.34 | 29-SEP-19:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 23542.55 | 6008.85 | 0.00 | 111233.97 | 0.00 |
October | 356602.19 | 04-OCT-19:49 | 66976.13 | 88772.42 | 14423.55 | 50900.13 | 21389.43 | 6403.84 | 0.00 | 101456.08 | 0.00 |
November | 286196.37 | 10-NOV-20:00 | 66976.13 | 88772.42 | 14423.55 | 50900.13 | 21616.07 | 4511.43 | 0.00 | 33206.80 | 0.00 |
December | 297877.07 | 05-DEC-20:10 | 66976.13 | 88772.42 | 14423.55 | 50891.06 | 21134.21 | 5034.88 | 0.00 | 45165.03 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 275116.18 | 59510.80 | 79417.81 | 14423.55 | 50575.94 | 19797.55 | 4467.84 | 0.00 | 31389.11 | 0.00 | |
Maximum of Months | 367340.34 | 66976.13 | 88772.42 | 14423.55 | 50900.13 | 23542.55 | 6403.84 | 0.00 | 111233.97 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportINTERIOREQUIPMENT:GAS {Maximum}[W] | INTERIOREQUIPMENT:GAS {TIMESTAMP} | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 104248.32 | 02-JAN-18:10 | 0.00 | 214982.90 | 08-JAN-06:00 | 0.00 | 175031.53 | 23-JAN-21:49 | 0.00 |
February | 104248.32 | 01-FEB-18:10 | 0.00 | 164076.39 | 05-FEB-05:00 | 0.00 | 175037.60 | 02-FEB-21:00 | 0.00 |
March | 104248.32 | 01-MAR-18:10 | 0.00 | 192134.91 | 30-MAR-02:00 | 0.00 | 174973.78 | 02-MAR-21:40 | 0.00 |
April | 104248.32 | 01-APR-17:10 | 0.00 | 149758.36 | 01-APR-04:00 | 0.00 | 174707.37 | 03-APR-20:30 | 0.00 |
May | 104248.32 | 01-MAY-17:10 | 0.00 | 141314.58 | 19-MAY-02:30 | 0.00 | 174417.59 | 02-MAY-20:00 | 0.00 |
June | 104248.32 | 01-JUN-17:10 | 0.00 | 108405.10 | 13-JUN-03:00 | 0.00 | 174056.71 | 01-JUN-20:40 | 0.00 |
July | 104248.32 | 01-JUL-17:10 | 0.00 | 41770.83 | 06-JUL-02:00 | 0.00 | 173870.11 | 07-JUL-20:30 | 0.00 |
August | 104248.32 | 01-AUG-17:10 | 0.00 | 18914.42 | 19-AUG-01:30 | 0.00 | 173815.01 | 29-AUG-20:19 | 0.00 |
September | 104248.32 | 01-SEP-17:10 | 0.00 | 108677.49 | 20-SEP-02:00 | 0.00 | 174018.83 | 29-SEP-20:30 | 0.00 |
October | 104248.32 | 02-OCT-17:10 | 0.00 | 141863.06 | 30-OCT-05:00 | 0.00 | 174352.90 | 31-OCT-20:49 | 0.00 |
November | 104248.32 | 01-NOV-17:10 | 0.00 | 151258.35 | 24-NOV-03:00 | 0.00 | 174664.25 | 30-NOV-21:19 | 0.00 |
December | 104248.32 | 01-DEC-18:10 | 0.00 | 168879.74 | 24-DEC-03:00 | 0.00 | 174928.29 | 29-DEC-21:19 | 0.00 |
Annual Sum or Average | |||||||||
Minimum of Months | 104248.32 | 0.00 | 18914.42 | 0.00 | 173815.01 | 0.00 | |||
Maximum of Months | 104248.32 | 0.00 | 214982.90 | 0.00 | 175037.60 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.33 | 20.25 | 1.33 | 20.25 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 2.33 | 20.36 | 2.33 | 20.36 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3.67 | 20.32 | 3.67 | 20.32 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.33 | 20.36 | 2.33 | 20.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.60 | 1.17 | 24.60 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.64 | 1.00 | 24.64 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.61 | 0.83 | 24.61 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.57 | 0.33 | 24.57 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.64 | 0.50 | 24.64 |
Annual Sum or Average | 0.00 | 0.00 | 3.83 | 24.61 | 3.83 | 24.61 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.64 | 1.17 | 24.64 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.96 | 0.67 | 21.96 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.82 | 1.33 | 21.82 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.00 | 21.87 | 2.00 | 21.87 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 21.96 | 1.33 | 21.96 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.87 | 0.33 | 21.87 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.90 | 0.17 | 21.90 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.50 | 21.88 | 0.50 | 21.88 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.90 | 0.33 | 21.90 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.67 | 0.33 | 21.67 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 21.72 | 0.50 | 21.72 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 21.77 | 0.50 | 21.77 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.80 | 0.67 | 21.80 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.76 | 0.33 | 21.76 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 2.33 | 21.75 | 2.33 | 21.75 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 21.80 | 0.67 | 21.80 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.75 | 0.33 | 21.75 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.50 | 21.72 | 0.50 | 21.72 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.75 | 0.33 | 21.75 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1.50 | 20.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.50 | 20.43 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1.50 | 20.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.70 | 0.33 | 21.70 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 22.09 | 1.33 | 22.09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 21.91 | 2.33 | 21.91 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.68 | 0.17 | 21.68 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.70 | 0.17 | 21.70 |
Annual Sum or Average | 0.00 | 0.00 | 4.67 | 21.91 | 4.67 | 21.91 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2.33 | 22.09 | 2.33 | 22.09 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 21.97 | 0.83 | 21.97 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 21.97 | 0.33 | 21.97 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.17 | 21.97 | 1.17 | 21.97 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 21.97 | 0.83 | 21.97 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 3.83 | 21.91 | 3.83 | 21.91 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 21.81 | 2.00 | 21.81 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 21.79 | 0.83 | 21.79 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 21.67 | 0.17 | 21.67 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 22.03 | 1.33 | 22.03 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 21.99 | 6.33 | 21.99 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 21.80 | 2.50 | 21.80 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 21.87 | 4.00 | 21.87 |
Annual Sum or Average | 0.00 | 0.00 | 21.00 | 21.91 | 21.00 | 21.91 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 22.03 | 6.33 | 22.03 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 15.00 | 24.66 | 15.00 | 24.66 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 9.17 | 24.63 | 9.17 | 24.63 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 13.50 | 24.69 | 13.50 | 24.69 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.60 | 0.50 | 24.60 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 24.65 | 2.83 | 24.65 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 12.50 | 24.68 | 12.50 | 24.68 |
Annual Sum or Average | 0.00 | 0.00 | 53.50 | 24.66 | 53.50 | 24.66 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 15.00 | 24.69 | 15.00 | 24.69 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 22.51 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 672.00 | 22.17 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 744.00 | 21.93 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 720.00 | 21.76 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 744.00 | 21.68 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 720.00 | 21.44 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 744.00 | 21.51 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 744.00 | 21.55 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 720.00 | 22.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 744.00 | 22.29 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 718.33 | 22.86 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 744.00 | 22.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 8758.33 | 22.02 | 0.00 | 0.00 | ||
Minimum of Months | 672.00 | 21.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 22.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 638.00 | 21.40 | 71.33 | 23.14 | 16.50 | 20.79 |
February | 615.67 | 21.35 | 25.67 | 23.10 | 5.83 | 21.00 |
March | 725.83 | 21.22 | 8.83 | 20.61 | 8.83 | 20.61 |
April | 720.00 | 21.19 | 0.33 | 21.00 | 0.33 | 21.00 |
May | 744.00 | 21.05 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 720.00 | 21.07 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 744.00 | 21.15 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 744.00 | 21.30 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 691.17 | 21.42 | 10.83 | 23.94 | 0.00 | 0.00 |
October | 620.83 | 21.53 | 74.67 | 23.84 | 0.00 | 0.00 |
November | 612.33 | 21.48 | 52.50 | 23.61 | 3.33 | 21.00 |
December | 617.50 | 21.48 | 56.83 | 23.67 | 5.00 | 21.00 |
Annual Sum or Average | 8193.33 | 21.29 | 301.00 | 23.45 | 39.83 | 20.83 |
Minimum of Months | 612.33 | 21.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.53 | 74.67 | 23.94 | 16.50 | 21.00 |
Report: ComfortReportSimple55Monthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 742.33 | 21.94 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 670.17 | 22.07 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 741.33 | 21.87 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 718.83 | 22.04 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 744.00 | 21.95 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 720.00 | 21.93 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 744.00 | 21.96 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 743.17 | 22.01 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 708.33 | 22.05 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 719.33 | 22.15 | 6.00 | 23.72 | 0.00 | 0.00 |
November | 715.67 | 22.25 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 741.83 | 22.10 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 8709.00 | 22.02 | 6.00 | 23.72 | 0.00 | |
Minimum of Months | 670.17 | 21.87 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 22.25 | 6.00 | 23.72 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 341.50 | 22.27 | 350.00 | 23.18 | 155.33 | 23.99 |
February | 282.67 | 22.58 | 346.50 | 23.17 | 148.33 | 24.00 |
March | 298.00 | 22.63 | 396.00 | 23.09 | 169.83 | 23.98 |
April | 255.67 | 23.00 | 411.83 | 22.93 | 173.83 | 23.93 |
May | 254.83 | 23.02 | 410.50 | 22.96 | 174.67 | 23.94 |
June | 215.17 | 23.26 | 420.00 | 22.68 | 168.17 | 23.89 |
July | 196.83 | 23.43 | 474.83 | 22.41 | 166.33 | 23.87 |
August | 201.83 | 23.41 | 492.17 | 22.37 | 169.67 | 23.86 |
September | 209.50 | 23.25 | 430.17 | 22.59 | 162.67 | 23.90 |
October | 261.17 | 22.75 | 391.17 | 22.81 | 155.83 | 23.93 |
November | 312.83 | 22.56 | 371.17 | 23.13 | 162.50 | 23.98 |
December | 375.00 | 22.22 | 349.00 | 23.20 | 152.00 | 24.01 |
Annual Sum or Average | 3205.00 | 22.78 | 4843.33 | 22.85 | 1959.17 | 23.94 |
Minimum of Months | 196.83 | 22.22 | 346.50 | 22.37 | 148.33 | 23.86 |
Maximum of Months | 375.00 | 23.43 | 492.17 | 23.20 | 174.67 | 24.01 |
Report: ComfortReportSimple55Monthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 557.17 | 22.28 | 112.33 | 23.59 | 13.50 | 23.21 |
February | 533.67 | 22.24 | 57.67 | 23.42 | 4.83 | 22.45 |
March | 666.33 | 21.98 | 12.00 | 23.22 | 0.17 | 23.18 |
April | 689.33 | 22.07 | 15.33 | 23.13 | 15.00 | 23.13 |
May | 732.50 | 21.90 | 14.00 | 23.00 | 12.50 | 22.96 |
June | 705.67 | 21.92 | 54.83 | 22.88 | 54.83 | 22.88 |
July | 707.33 | 21.93 | 74.33 | 22.86 | 72.83 | 22.86 |
August | 669.50 | 22.03 | 92.83 | 23.00 | 82.33 | 22.96 |
September | 599.17 | 22.22 | 135.50 | 23.20 | 90.50 | 23.07 |
October | 442.50 | 22.30 | 161.00 | 23.60 | 9.00 | 23.69 |
November | 487.17 | 22.51 | 129.83 | 23.58 | 7.33 | 23.04 |
December | 527.00 | 22.45 | 119.33 | 23.77 | 0.00 | 0.00 |
Annual Sum or Average | 7317.33 | 22.12 | 979.00 | 23.38 | 362.83 | 22.98 |
Minimum of Months | 442.50 | 21.90 | 12.00 | 22.86 | 0.00 | 0.00 |
Maximum of Months | 732.50 | 22.51 | 161.00 | 23.77 | 90.50 | 23.69 |
Report: ComfortReportSimple55Monthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 698.17 | 22.36 | 12.83 | 23.47 | 5.67 | 23.13 |
February | 617.33 | 22.44 | 7.00 | 23.54 | 1.67 | 22.61 |
March | 701.50 | 22.21 | 5.67 | 23.77 | 0.00 | 0.00 |
April | 648.83 | 22.25 | 9.17 | 23.63 | 0.00 | 0.00 |
May | 697.67 | 22.18 | 2.00 | 23.52 | 0.00 | 0.00 |
June | 655.33 | 22.10 | 6.50 | 23.31 | 2.50 | 23.01 |
July | 681.17 | 22.10 | 5.00 | 23.48 | 0.00 | 0.00 |
August | 656.83 | 22.12 | 16.33 | 23.34 | 4.67 | 22.95 |
September | 624.00 | 22.23 | 23.83 | 23.57 | 0.00 | 0.00 |
October | 645.67 | 22.44 | 31.67 | 23.73 | 3.17 | 23.58 |
November | 627.00 | 22.59 | 24.33 | 23.79 | 0.00 | 0.00 |
December | 700.83 | 22.54 | 8.00 | 23.85 | 0.00 | 0.00 |
Annual Sum or Average | 7954.33 | 22.30 | 152.33 | 23.61 | 17.67 | 23.10 |
Minimum of Months | 617.33 | 22.10 | 2.00 | 23.31 | 0.00 | 0.00 |
Maximum of Months | 701.50 | 22.59 | 31.67 | 23.85 | 5.67 | 23.58 |
Report: ComfortReportSimple55Monthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 741.17 | 21.46 | 21.00 | 21.10 | 21.00 | 21.10 |
February | 665.17 | 21.36 | 15.17 | 21.01 | 15.17 | 21.01 |
March | 736.83 | 21.31 | 17.00 | 20.42 | 17.00 | 20.42 |
April | 705.17 | 21.44 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 740.83 | 21.42 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 704.83 | 21.46 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 703.17 | 21.49 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 694.50 | 21.49 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 680.67 | 21.48 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 713.17 | 21.49 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 707.83 | 21.48 | 19.17 | 21.10 | 19.17 | 21.10 |
December | 742.00 | 21.49 | 31.33 | 21.11 | 31.33 | 21.11 |
Annual Sum or Average | 8535.33 | 21.45 | 103.67 | 20.98 | 103.67 | 20.98 |
Minimum of Months | 665.17 | 21.31 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 742.00 | 21.49 | 31.33 | 21.11 | 31.33 | 21.11 |
Report: ComfortReportSimple55Monthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.17 | 97.50 | 20.86 | 97.50 | 20.86 |
February | 672.00 | 21.18 | 39.83 | 20.95 | 39.83 | 20.95 |
March | 743.50 | 21.19 | 21.17 | 20.38 | 21.17 | 20.38 |
April | 714.50 | 21.37 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 742.33 | 21.40 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 704.00 | 21.45 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 703.50 | 21.49 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 707.67 | 21.48 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 705.83 | 21.43 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 739.50 | 21.41 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 720.00 | 21.28 | 51.83 | 21.07 | 51.83 | 21.07 |
December | 744.00 | 21.20 | 93.50 | 21.01 | 93.50 | 21.01 |
Annual Sum or Average | 8640.83 | 21.34 | 303.83 | 20.92 | 303.83 | 20.92 |
Minimum of Months | 672.00 | 21.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.49 | 97.50 | 21.07 | 97.50 | 21.07 |
Report: ComfortReportSimple55Monthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.13 | 36.00 | 20.93 | 36.00 | 20.93 |
February | 672.00 | 21.17 | 20.50 | 21.10 | 20.50 | 21.10 |
March | 744.00 | 21.18 | 1.00 | 20.44 | 1.00 | 20.44 |
April | 720.00 | 21.25 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 744.00 | 21.27 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 720.00 | 21.31 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 744.00 | 21.35 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 744.00 | 21.33 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 720.00 | 21.28 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 744.00 | 21.27 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 720.00 | 21.17 | 49.67 | 21.12 | 49.67 | 21.12 |
December | 744.00 | 21.14 | 54.00 | 21.10 | 54.00 | 21.10 |
Annual Sum or Average | 8760.00 | 21.24 | 161.17 | 21.06 | 161.17 | 21.06 |
Minimum of Months | 672.00 | 21.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.35 | 54.00 | 21.12 | 54.00 | 21.12 |
Report: ComfortReportSimple55Monthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.51 | 24.17 | 21.11 | 24.17 | 21.11 |
February | 672.00 | 21.40 | 16.17 | 21.02 | 16.17 | 21.02 |
March | 744.00 | 21.37 | 20.17 | 20.48 | 20.17 | 20.48 |
April | 719.50 | 21.54 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 744.00 | 21.45 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 718.00 | 21.51 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 735.33 | 21.64 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 729.17 | 21.65 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 714.50 | 21.57 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 741.67 | 21.58 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 720.00 | 21.53 | 20.00 | 21.11 | 20.00 | 21.11 |
December | 744.00 | 21.52 | 34.00 | 21.11 | 34.00 | 21.11 |
Annual Sum or Average | 8726.17 | 21.52 | 114.50 | 20.99 | 114.50 | 20.99 |
Minimum of Months | 672.00 | 21.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.65 | 34.00 | 21.11 | 34.00 | 21.11 |
Report: ComfortReportSimple55Monthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.16 | 62.50 | 21.03 | 62.50 | 21.03 |
February | 672.00 | 21.16 | 29.17 | 20.92 | 29.17 | 20.92 |
March | 744.00 | 21.22 | 26.33 | 20.51 | 26.33 | 20.51 |
April | 719.67 | 21.44 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 744.00 | 21.43 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 717.67 | 21.51 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 735.33 | 21.63 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 732.83 | 21.62 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 719.00 | 21.45 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 744.00 | 21.44 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 720.00 | 21.22 | 48.00 | 21.09 | 48.00 | 21.09 |
December | 744.00 | 21.16 | 69.50 | 21.08 | 69.50 | 21.08 |
Annual Sum or Average | 8736.50 | 21.37 | 235.50 | 20.98 | 235.50 | 20.98 |
Minimum of Months | 672.00 | 21.16 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.63 | 69.50 | 21.09 | 69.50 | 21.09 |
Report: ComfortReportSimple55Monthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 734.67 | 21.43 | 63.17 | 21.03 | 63.17 | 21.03 |
February | 658.33 | 21.32 | 33.83 | 20.89 | 33.83 | 20.89 |
March | 726.67 | 21.28 | 39.33 | 20.61 | 39.33 | 20.61 |
April | 686.17 | 21.44 | 4.50 | 21.01 | 4.50 | 21.01 |
May | 723.50 | 21.43 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 674.33 | 21.45 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 659.67 | 21.45 | 1.67 | 22.44 | 0.17 | 21.27 |
August | 651.33 | 21.43 | 6.83 | 22.10 | 4.00 | 21.58 |
September | 654.67 | 21.44 | 4.83 | 21.95 | 3.17 | 21.36 |
October | 696.67 | 21.47 | 2.00 | 22.96 | 0.33 | 21.90 |
November | 696.00 | 21.44 | 33.83 | 21.10 | 33.83 | 21.10 |
December | 738.67 | 21.46 | 65.50 | 21.09 | 65.50 | 21.09 |
Annual Sum or Average | 8300.67 | 21.42 | 255.50 | 21.04 | 247.83 | 20.98 |
Minimum of Months | 651.33 | 21.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 738.67 | 21.47 | 65.50 | 22.96 | 65.50 | 21.90 |
Report: ComfortReportSimple55Monthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 744.00 | 21.14 | 151.17 | 20.83 | 151.17 | 20.83 |
February | 672.00 | 21.16 | 58.83 | 20.78 | 58.83 | 20.78 |
March | 741.83 | 21.18 | 53.83 | 20.61 | 53.83 | 20.61 |
April | 700.00 | 21.39 | 8.00 | 21.04 | 8.00 | 21.04 |
May | 727.17 | 21.43 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 673.33 | 21.45 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 663.17 | 21.46 | 0.67 | 21.98 | 0.17 | 21.28 |
August | 667.50 | 21.45 | 7.17 | 21.70 | 6.00 | 21.48 |
September | 684.33 | 21.44 | 6.00 | 21.26 | 6.00 | 21.26 |
October | 728.83 | 21.42 | 7.17 | 21.06 | 7.17 | 21.06 |
November | 720.00 | 21.27 | 70.17 | 21.03 | 70.17 | 21.03 |
December | 744.00 | 21.17 | 152.17 | 20.96 | 152.17 | 20.96 |
Annual Sum or Average | 8466.17 | 21.33 | 515.17 | 20.89 | 513.50 | 20.89 |
Minimum of Months | 663.17 | 21.14 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.46 | 152.17 | 21.98 | 152.17 | 21.48 |
Report: ComfortReportSimple55Monthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 678.33 | 21.47 | 4.83 | 22.34 | 2.17 | 21.11 |
February | 637.33 | 21.43 | 3.50 | 21.11 | 3.50 | 21.11 |
March | 711.50 | 21.37 | 14.50 | 20.45 | 14.50 | 20.45 |
April | 713.00 | 21.53 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 744.00 | 21.40 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 720.00 | 21.45 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 743.33 | 21.56 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 714.50 | 21.55 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 644.50 | 21.42 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 661.67 | 21.43 | 3.67 | 23.33 | 0.00 | 0.00 |
November | 658.17 | 21.50 | 6.00 | 21.91 | 3.83 | 21.11 |
December | 685.17 | 21.51 | 6.00 | 21.73 | 4.33 | 21.11 |
Annual Sum or Average | 8311.50 | 21.47 | 38.50 | 21.45 | 28.33 | 20.77 |
Minimum of Months | 637.33 | 21.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 744.00 | 21.56 | 14.50 | 23.33 | 14.50 | 21.11 |
Report: ComfortReportSimple55Monthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 433.50 | 22.59 | 182.33 | 23.96 | 17.67 | 23.99 |
February | 310.00 | 22.73 | 217.67 | 23.96 | 12.33 | 23.97 |
March | 316.00 | 22.58 | 273.67 | 23.94 | 3.00 | 23.99 |
April | 224.17 | 22.60 | 401.50 | 23.89 | 23.67 | 23.98 |
May | 228.50 | 22.57 | 418.83 | 23.90 | 28.50 | 23.99 |
June | 259.83 | 22.94 | 480.50 | 23.82 | 98.67 | 23.99 |
July | 291.17 | 23.21 | 519.00 | 23.77 | 156.00 | 23.99 |
August | 330.00 | 23.18 | 509.50 | 23.77 | 172.00 | 23.98 |
September | 286.00 | 22.95 | 444.17 | 23.82 | 118.33 | 23.97 |
October | 301.00 | 22.62 | 312.67 | 23.87 | 44.50 | 23.94 |
November | 338.83 | 22.67 | 234.00 | 23.93 | 17.50 | 23.78 |
December | 448.00 | 22.70 | 130.33 | 23.96 | 0.00 | 0.00 |
Annual Sum or Average | 3767.00 | 22.77 | 4124.17 | 23.86 | 692.17 | 23.97 |
Minimum of Months | 224.17 | 22.57 | 130.33 | 23.77 | 0.00 | 0.00 |
Maximum of Months | 448.00 | 23.21 | 519.00 | 23.96 | 172.00 | 23.99 |
Report: ComfortReportSimple55Monthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 318.50 | 22.64 | 278.33 | 23.92 | 12.67 | 23.99 |
February | 176.67 | 22.74 | 326.50 | 23.91 | 10.50 | 23.99 |
March | 162.83 | 22.64 | 409.00 | 23.89 | 1.67 | 23.99 |
April | 74.33 | 22.80 | 502.00 | 23.86 | 13.33 | 23.99 |
May | 77.17 | 22.95 | 534.33 | 23.85 | 21.67 | 23.99 |
June | 107.33 | 23.63 | 550.83 | 23.80 | 82.17 | 23.99 |
July | 137.17 | 23.99 | 598.00 | 23.75 | 137.17 | 23.99 |
August | 151.50 | 23.98 | 576.17 | 23.76 | 150.67 | 23.99 |
September | 163.50 | 23.38 | 541.33 | 23.77 | 103.17 | 23.99 |
October | 176.17 | 22.70 | 418.50 | 23.83 | 30.00 | 23.99 |
November | 214.00 | 22.66 | 338.83 | 23.89 | 8.50 | 23.95 |
December | 311.00 | 22.68 | 217.50 | 23.92 | 0.00 | 0.00 |
Annual Sum or Average | 2070.17 | 22.98 | 5291.33 | 23.83 | 571.50 | 23.99 |
Minimum of Months | 74.33 | 22.64 | 217.50 | 23.75 | 0.00 | 0.00 |
Maximum of Months | 318.50 | 23.99 | 598.00 | 23.92 | 150.67 | 23.99 |
Report: ComfortReportSimple55Monthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 582.00 | 23.74 | 634.33 | 23.85 | 518.33 | 24.05 |
February | 497.00 | 23.93 | 608.17 | 23.82 | 474.33 | 24.04 |
March | 572.50 | 23.83 | 676.17 | 23.82 | 527.00 | 24.05 |
April | 525.33 | 24.00 | 707.83 | 23.72 | 522.50 | 24.01 |
May | 544.50 | 24.00 | 728.33 | 23.71 | 543.67 | 24.00 |
June | 534.50 | 23.99 | 719.67 | 23.61 | 534.50 | 23.99 |
July | 551.67 | 23.98 | 743.67 | 23.55 | 551.67 | 23.98 |
August | 552.00 | 23.98 | 740.83 | 23.55 | 552.00 | 23.98 |
September | 530.33 | 23.98 | 710.67 | 23.59 | 529.50 | 23.98 |
October | 545.00 | 23.95 | 690.17 | 23.69 | 535.83 | 23.99 |
November | 532.50 | 23.92 | 652.17 | 23.81 | 508.33 | 24.03 |
December | 585.17 | 23.72 | 620.83 | 23.90 | 513.67 | 24.04 |
Annual Sum or Average | 6552.50 | 23.92 | 8232.83 | 23.71 | 6311.33 | 24.01 |
Minimum of Months | 497.00 | 23.72 | 608.17 | 23.55 | 474.33 | 23.98 |
Maximum of Months | 585.17 | 24.00 | 743.67 | 23.90 | 552.00 | 24.05 |
Report: ComfortReportSimple55Monthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BASEMENT PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.51412 | 39.90208 | -0.0197 | 5.31554 |
February | 672.00000 | 22.16560 | 43.44156 | -0.0949 | 5.42083 |
March | 744.00000 | 21.92815 | 47.71452 | -0.1285 | 5.54492 |
April | 720.00000 | 21.75737 | 52.89977 | -0.1396 | 5.59807 |
May | 744.00000 | 21.67925 | 52.94917 | -1.2962 | 40.22658 |
June | 720.00000 | 21.43646 | 59.05161 | -1.3423 | 42.57965 |
July | 744.00000 | 21.50535 | 59.79308 | -1.3026 | 40.53808 |
August | 744.00000 | 21.55076 | 59.62575 | -1.2862 | 39.71235 |
September | 720.00000 | 22.00301 | 56.95735 | -1.1414 | 32.66603 |
October | 744.00000 | 22.28872 | 46.69440 | -0.0291 | 5.27345 |
November | 720.00000 | 22.85969 | 40.77835 | 0.07148 | 5.39482 |
December | 744.00000 | 22.59496 | 34.57697 | -0.0340 | 5.39957 |
Annual Sum or Average | 8760.00000 | 22.02256 | 49.55044 | -0.5649 | 19.56511 |
Minimum of Months | 672.00000 | 21.43646 | 34.57697 | -1.3423 | 5.27345 |
Maximum of Months | 744.00000 | 22.85969 | 59.79308 | 0.07148 | 42.57965 |
Report: OccupantComfortDataSummaryMonthly
For: RETAIL_1_FLR_1 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.72650 | 40.69698 | -0.1296 | 7.11592 |
February | 672.00000 | 21.53312 | 44.05894 | -0.1742 | 6.82799 |
March | 744.00000 | 21.26666 | 48.48604 | -0.2306 | 6.87878 |
April | 720.00000 | 21.19130 | 53.64736 | -0.1962 | 6.11318 |
May | 744.00000 | 21.05449 | 53.81865 | -1.4107 | 46.15942 |
June | 720.00000 | 21.07324 | 59.66795 | -1.3445 | 42.63629 |
July | 744.00000 | 21.15014 | 61.24750 | -1.2831 | 39.49786 |
August | 744.00000 | 21.30109 | 61.00847 | -1.2199 | 36.46093 |
September | 720.00000 | 21.49888 | 58.37725 | -1.1682 | 34.65404 |
October | 744.00000 | 21.87170 | 47.37599 | -0.0227 | 6.51519 |
November | 720.00000 | 21.80221 | 42.23568 | -0.0896 | 6.72064 |
December | 744.00000 | 21.87053 | 35.12345 | -0.1192 | 7.18301 |
Annual Sum or Average | 8760.00000 | 21.44485 | 50.49854 | -0.6184 | 20.65494 |
Minimum of Months | 672.00000 | 21.05449 | 35.12345 | -1.4107 | 6.11318 |
Maximum of Months | 744.00000 | 21.87170 | 61.24750 | -0.0227 | 46.15942 |
Report: OccupantComfortDataSummaryMonthly
For: RETAIL_2_FLR_1 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.94264 | 41.67484 | -0.1064 | 5.78110 |
February | 672.00000 | 22.07691 | 44.31259 | -0.0634 | 5.49406 |
March | 744.00000 | 21.87784 | 48.45301 | -0.0884 | 5.66009 |
April | 720.00000 | 22.03966 | 52.71365 | -0.0157 | 5.48855 |
May | 744.00000 | 21.94575 | 52.81984 | -1.1288 | 32.44305 |
June | 720.00000 | 21.92773 | 58.21597 | -1.0913 | 30.75845 |
July | 744.00000 | 21.95947 | 59.27766 | -1.0645 | 29.50692 |
August | 744.00000 | 22.01125 | 59.18234 | -1.0453 | 28.66913 |
September | 720.00000 | 22.06633 | 57.61166 | -1.0399 | 28.41344 |
October | 744.00000 | 22.19223 | 47.70905 | 0.00478 | 5.46654 |
November | 720.00000 | 22.25989 | 42.70707 | -0.0210 | 5.44220 |
December | 744.00000 | 22.10212 | 36.16657 | -0.0999 | 5.63683 |
Annual Sum or Average | 8760.00000 | 22.03269 | 50.08763 | -0.4827 | 15.79448 |
Minimum of Months | 672.00000 | 21.87784 | 36.16657 | -1.1288 | 5.44220 |
Maximum of Months | 744.00000 | 22.25989 | 59.27766 | 0.00478 | 32.44305 |
Report: OccupantComfortDataSummaryMonthly
For: LAUNDRY_FLR_1 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.03368 | 37.44146 | 0.50666 | 14.47048 |
February | 672.00000 | 22.17633 | 39.95985 | 0.55360 | 15.19553 |
March | 744.00000 | 22.12666 | 43.86439 | 0.56607 | 15.58083 |
April | 720.00000 | 22.12730 | 48.52364 | 0.60891 | 16.43046 |
May | 744.00000 | 22.09774 | 48.40563 | -0.2062 | 13.29661 |
June | 720.00000 | 21.97951 | 54.04553 | -0.1961 | 13.17329 |
July | 744.00000 | 21.90253 | 55.30081 | -0.2030 | 12.92210 |
August | 744.00000 | 21.90876 | 55.27283 | -0.1969 | 13.03769 |
September | 720.00000 | 21.95069 | 53.87749 | -0.2079 | 13.12878 |
October | 744.00000 | 21.96758 | 44.10546 | 0.55565 | 15.14036 |
November | 720.00000 | 22.14443 | 38.86644 | 0.54904 | 15.14470 |
December | 744.00000 | 22.08900 | 32.10027 | 0.48816 | 13.82694 |
Annual Sum or Average | 8760.00000 | 22.04082 | 45.99859 | 0.23272 | 14.26936 |
Minimum of Months | 672.00000 | 21.90253 | 32.10027 | -0.2079 | 12.92210 |
Maximum of Months | 744.00000 | 22.17633 | 55.30081 | 0.60891 | 16.43046 |
Report: OccupantComfortDataSummaryMonthly
For: CAFE_FLR_1 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.57271 | 44.62632 | 0.14528 | 6.66822 |
February | 672.00000 | 22.46213 | 47.75509 | 0.11423 | 6.16855 |
March | 744.00000 | 22.07975 | 52.09353 | 0.03262 | 5.89084 |
April | 720.00000 | 22.12232 | 56.69929 | 0.08293 | 5.62558 |
May | 744.00000 | 21.91985 | 57.04592 | -1.0542 | 29.17271 |
June | 720.00000 | 21.94127 | 62.44187 | -0.9908 | 26.50700 |
July | 744.00000 | 21.98550 | 63.68413 | -0.9429 | 24.47946 |
August | 744.00000 | 22.13418 | 63.40864 | -0.8783 | 21.94920 |
September | 720.00000 | 22.36169 | 61.12292 | -0.8106 | 19.70353 |
October | 744.00000 | 22.72316 | 50.88774 | 0.24390 | 7.15158 |
November | 720.00000 | 22.80747 | 45.85394 | 0.21408 | 6.78295 |
December | 744.00000 | 22.76914 | 39.38987 | 0.16658 | 6.67639 |
Annual Sum or Average | 8760.00000 | 22.32229 | 53.76960 | -0.3091 | 13.95324 |
Minimum of Months | 672.00000 | 21.91985 | 39.38987 | -1.0542 | 5.62558 |
Maximum of Months | 744.00000 | 22.80747 | 63.68413 | 0.24390 | 29.17271 |
Report: OccupantComfortDataSummaryMonthly
For: LOBBY_FLR_1 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 22.43083 | 43.77658 | 0.04763 | 5.66467 |
February | 672.00000 | 22.53539 | 46.42468 | 0.08103 | 5.63378 |
March | 744.00000 | 22.28973 | 50.53161 | 0.04292 | 5.68061 |
April | 720.00000 | 22.36959 | 54.92684 | 0.09607 | 5.82181 |
May | 744.00000 | 22.26097 | 55.05417 | -0.9860 | 26.57000 |
June | 720.00000 | 22.21616 | 60.42969 | -0.9543 | 25.32813 |
July | 744.00000 | 22.20467 | 61.62611 | -0.9396 | 24.63231 |
August | 744.00000 | 22.26490 | 61.54120 | -0.9161 | 23.67843 |
September | 720.00000 | 22.38518 | 59.75075 | -0.8884 | 22.51019 |
October | 744.00000 | 22.57823 | 49.92040 | 0.13704 | 5.91255 |
November | 720.00000 | 22.72543 | 44.86380 | 0.12837 | 5.83971 |
December | 744.00000 | 22.60058 | 38.45768 | 0.05734 | 5.52086 |
Annual Sum or Average | 8760.00000 | 22.40386 | 52.29360 | -0.3439 | 13.61694 |
Minimum of Months | 672.00000 | 22.20467 | 38.45768 | -0.9860 | 5.52086 |
Maximum of Months | 744.00000 | 22.72543 | 61.62611 | 0.13704 | 26.57000 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_1_FLR_3 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.46494 | 46.34382 | -0.2698 | 7.30163 |
February | 672.00000 | 21.37545 | 49.42504 | -0.2748 | 7.20591 |
March | 744.00000 | 21.32734 | 53.03657 | -0.2694 | 7.16900 |
April | 720.00000 | 21.47098 | 56.37058 | -0.1746 | 6.23413 |
May | 744.00000 | 21.42499 | 56.37924 | -1.3442 | 43.12307 |
June | 720.00000 | 21.48534 | 60.50492 | -1.2675 | 39.31611 |
July | 744.00000 | 21.57497 | 61.60228 | -1.2014 | 36.26371 |
August | 744.00000 | 21.59690 | 62.08144 | -1.1902 | 35.82291 |
September | 720.00000 | 21.56602 | 60.71735 | -1.2274 | 37.60164 |
October | 744.00000 | 21.55865 | 51.57826 | -0.1595 | 6.32091 |
November | 720.00000 | 21.50954 | 47.58163 | -0.2339 | 6.96866 |
December | 744.00000 | 21.49325 | 40.80525 | -0.2884 | 7.54100 |
Annual Sum or Average | 8760.00000 | 21.48806 | 53.87882 | -0.6608 | 20.15121 |
Minimum of Months | 672.00000 | 21.32734 | 40.80525 | -1.3442 | 6.23413 |
Maximum of Months | 744.00000 | 21.59690 | 62.08144 | -0.1595 | 43.12307 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_2_FLR_3 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.17038 | 47.26050 | -0.3777 | 8.39325 |
February | 672.00000 | 21.18043 | 50.07761 | -0.3472 | 7.86725 |
March | 744.00000 | 21.18628 | 53.63136 | -0.3197 | 7.54144 |
April | 720.00000 | 21.38278 | 56.90447 | -0.2051 | 6.34753 |
May | 744.00000 | 21.40675 | 56.49379 | -1.3526 | 43.51404 |
June | 720.00000 | 21.48428 | 60.43056 | -1.2671 | 39.28958 |
July | 744.00000 | 21.56754 | 61.62513 | -1.2048 | 36.39324 |
August | 744.00000 | 21.55124 | 62.74578 | -1.2126 | 36.74952 |
September | 720.00000 | 21.46199 | 62.03073 | -1.2792 | 39.83310 |
October | 744.00000 | 21.41851 | 52.59451 | -0.2153 | 6.51226 |
November | 720.00000 | 21.27953 | 48.54992 | -0.3230 | 7.67484 |
December | 744.00000 | 21.19923 | 41.58616 | -0.4003 | 8.72630 |
Annual Sum or Average | 8760.00000 | 21.35838 | 54.50328 | -0.7110 | 20.81470 |
Minimum of Months | 672.00000 | 21.17038 | 41.58616 | -1.3526 | 6.34753 |
Maximum of Months | 744.00000 | 21.56754 | 62.74578 | -0.2051 | 43.51404 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_3_MULT19_FLR_3 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_4_MULT19_FLR_3 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.13467 | 45.29376 | -0.3814 | 8.20179 |
February | 672.00000 | 21.17089 | 48.18037 | -0.3493 | 7.67011 |
March | 744.00000 | 21.17980 | 51.76963 | -0.3242 | 7.29876 |
April | 720.00000 | 21.24710 | 55.35517 | -0.2694 | 6.58071 |
May | 744.00000 | 21.26960 | 54.76687 | -1.4383 | 47.60055 |
June | 720.00000 | 21.30567 | 58.89646 | -1.3830 | 44.67706 |
July | 744.00000 | 21.35330 | 60.91656 | -1.3466 | 42.80536 |
August | 744.00000 | 21.33164 | 61.96716 | -1.3539 | 43.16390 |
September | 720.00000 | 21.27635 | 60.39114 | -1.3963 | 45.37121 |
October | 744.00000 | 21.27456 | 50.77757 | -0.2798 | 6.80783 |
November | 720.00000 | 21.17477 | 46.76453 | -0.3534 | 7.78428 |
December | 744.00000 | 21.13743 | 39.74321 | -0.4120 | 8.70170 |
Annual Sum or Average | 8760.00000 | 21.23839 | 52.91383 | -0.7766 | 23.14832 |
Minimum of Months | 672.00000 | 21.13467 | 39.74321 | -1.4383 | 6.58071 |
Maximum of Months | 744.00000 | 21.35330 | 61.96716 | -0.2694 | 47.60055 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_5_FLR_3 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.50697 | 46.17227 | -0.2579 | 7.10822 |
February | 672.00000 | 21.39822 | 49.39128 | -0.2739 | 7.15830 |
March | 744.00000 | 21.37456 | 52.81248 | -0.2602 | 7.09111 |
April | 720.00000 | 21.54087 | 55.99241 | -0.1662 | 6.19987 |
May | 744.00000 | 21.45222 | 56.19149 | -1.3486 | 43.27364 |
June | 720.00000 | 21.51647 | 60.46904 | -1.2756 | 39.68256 |
July | 744.00000 | 21.64782 | 61.49628 | -1.1916 | 35.86893 |
August | 744.00000 | 21.67423 | 61.79054 | -1.1740 | 35.16909 |
September | 720.00000 | 21.58259 | 61.04649 | -1.2397 | 38.16745 |
October | 744.00000 | 21.58716 | 51.63686 | -0.1566 | 6.25519 |
November | 720.00000 | 21.52544 | 47.61102 | -0.2348 | 6.86522 |
December | 744.00000 | 21.52115 | 40.78645 | -0.2826 | 7.38714 |
Annual Sum or Average | 8760.00000 | 21.52822 | 53.79179 | -0.6575 | 20.09490 |
Minimum of Months | 672.00000 | 21.37456 | 40.78645 | -1.3486 | 6.19987 |
Maximum of Months | 744.00000 | 21.67423 | 61.79054 | -0.1566 | 43.27364 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_6_FLR_3 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.16327 | 47.16572 | -0.3744 | 8.20503 |
February | 672.00000 | 21.16429 | 50.16066 | -0.3538 | 7.83017 |
March | 744.00000 | 21.21845 | 53.48698 | -0.3132 | 7.42334 |
April | 720.00000 | 21.43958 | 56.54332 | -0.1995 | 6.25785 |
May | 744.00000 | 21.43126 | 56.32113 | -1.3579 | 43.69837 |
June | 720.00000 | 21.51508 | 60.44336 | -1.2749 | 39.63738 |
July | 744.00000 | 21.64306 | 61.56420 | -1.1939 | 35.94744 |
August | 744.00000 | 21.63490 | 62.37380 | -1.1953 | 36.00529 |
September | 720.00000 | 21.45322 | 62.31411 | -1.3001 | 40.75405 |
October | 744.00000 | 21.43557 | 52.73733 | -0.2146 | 6.37338 |
November | 720.00000 | 21.21665 | 48.73861 | -0.3393 | 7.67553 |
December | 744.00000 | 21.16410 | 41.67257 | -0.4062 | 8.64245 |
Annual Sum or Average | 8760.00000 | 21.37464 | 54.46755 | -0.7124 | 20.77848 |
Minimum of Months | 672.00000 | 21.16327 | 41.67257 | -1.3579 | 6.25785 |
Maximum of Months | 744.00000 | 21.64306 | 62.37380 | -0.1995 | 43.69837 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_1_FLR_6 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.45075 | 46.97087 | -0.2855 | 7.66706 |
February | 672.00000 | 21.35700 | 50.22041 | -0.2896 | 7.54177 |
March | 744.00000 | 21.32298 | 53.81790 | -0.2791 | 7.50374 |
April | 720.00000 | 21.51583 | 56.94582 | -0.1605 | 6.37538 |
May | 744.00000 | 21.47667 | 56.86935 | -1.3236 | 42.35123 |
June | 720.00000 | 21.55178 | 60.67577 | -1.2321 | 37.91707 |
July | 744.00000 | 21.64165 | 61.51119 | -1.1572 | 34.55345 |
August | 744.00000 | 21.64961 | 62.09311 | -1.1508 | 34.33860 |
September | 720.00000 | 21.60458 | 61.19604 | -1.2010 | 36.65660 |
October | 744.00000 | 21.57648 | 51.97291 | -0.1502 | 6.45622 |
November | 720.00000 | 21.50340 | 48.30851 | -0.2424 | 7.21760 |
December | 744.00000 | 21.47733 | 41.34204 | -0.3047 | 7.90728 |
Annual Sum or Average | 8760.00000 | 21.51157 | 54.33385 | -0.6503 | 19.78157 |
Minimum of Months | 672.00000 | 21.32298 | 41.34204 | -1.3236 | 6.37538 |
Maximum of Months | 744.00000 | 21.64961 | 62.09311 | -0.1502 | 42.35123 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_2_FLR_6 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.14456 | 47.98514 | -0.4004 | 8.87673 |
February | 672.00000 | 21.15624 | 50.92550 | -0.3666 | 8.25167 |
March | 744.00000 | 21.18290 | 54.45847 | -0.3312 | 7.86567 |
April | 720.00000 | 21.43540 | 57.52263 | -0.1904 | 6.43679 |
May | 744.00000 | 21.46150 | 56.98059 | -1.3313 | 42.68879 |
June | 720.00000 | 21.55191 | 60.60285 | -1.2312 | 37.86685 |
July | 744.00000 | 21.63893 | 61.53272 | -1.1591 | 34.61638 |
August | 744.00000 | 21.62254 | 62.69434 | -1.1685 | 35.02724 |
September | 720.00000 | 21.52104 | 62.53807 | -1.2485 | 38.59709 |
October | 744.00000 | 21.45415 | 53.04132 | -0.2043 | 6.59882 |
November | 720.00000 | 21.27303 | 49.35727 | -0.3361 | 7.96725 |
December | 744.00000 | 21.17201 | 42.19069 | -0.4244 | 9.21960 |
Annual Sum or Average | 8760.00000 | 21.38573 | 54.99156 | -0.7015 | 20.40761 |
Minimum of Months | 672.00000 | 21.14456 | 42.19069 | -1.3313 | 6.43679 |
Maximum of Months | 744.00000 | 21.63893 | 62.69434 | -0.1904 | 42.68879 |
Report: OccupantComfortDataSummaryMonthly
For: ROOM_3_MULT9_FLR_6 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 21.63502 | 45.72055 | -0.1785 | 6.87706 |
February | 672.00000 | 21.52391 | 48.95208 | -0.2144 | 6.91108 |
March | 744.00000 | 21.45464 | 52.42413 | -0.2328 | 7.07710 |
April | 720.00000 | 21.54605 | 55.95158 | -0.1737 | 6.37820 |
May | 744.00000 | 21.39881 | 56.55383 | -1.3943 | 45.59233 |
June | 720.00000 | 21.44544 | 61.05031 | -1.3247 | 42.00551 |
July | 744.00000 | 21.56202 | 62.32479 | -1.2488 | 38.46678 |
August | 744.00000 | 21.62264 | 61.92365 | -1.2102 | 36.88720 |
September | 720.00000 | 21.61381 | 59.28586 | -1.2204 | 37.59610 |
October | 744.00000 | 21.63462 | 50.36824 | -0.1238 | 6.38370 |
November | 720.00000 | 21.65568 | 46.69260 | -0.1613 | 6.72574 |
December | 744.00000 | 21.65390 | 40.46499 | -0.1954 | 7.07126 |
Annual Sum or Average | 8760.00000 | 21.56249 | 53.48837 | -0.6425 | 20.74985 |
Minimum of Months | 672.00000 | 21.39881 | 40.46499 | -1.3943 | 6.37820 |
Maximum of Months | 744.00000 | 21.65568 | 62.32479 | -0.1238 | 45.59233 |
Report: OccupantComfortDataSummaryMonthly
For: BANQUET_FLR_6 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.10475 | 44.46403 | 0.23906 | 7.05447 |
February | 672.00000 | 23.31285 | 46.47515 | 0.30339 | 7.52573 |
March | 744.00000 | 23.27235 | 50.06192 | 0.32141 | 7.72001 |
April | 720.00000 | 23.38452 | 53.95886 | 0.39430 | 8.72303 |
May | 744.00000 | 23.37738 | 53.78129 | -0.5279 | 11.63428 |
June | 720.00000 | 23.37315 | 58.74837 | -0.4719 | 10.50672 |
July | 744.00000 | 23.38886 | 59.74192 | -0.4432 | 9.85279 |
August | 744.00000 | 23.36362 | 59.87565 | -0.4534 | 10.09626 |
September | 720.00000 | 23.31570 | 58.86233 | -0.4988 | 11.11081 |
October | 744.00000 | 23.27553 | 50.05432 | 0.35426 | 8.27616 |
November | 720.00000 | 23.27639 | 45.44886 | 0.29318 | 7.50325 |
December | 744.00000 | 23.15933 | 39.46993 | 0.21866 | 6.73315 |
Annual Sum or Average | 8760.00000 | 23.29986 | 51.76103 | -0.0247 | 8.89977 |
Minimum of Months | 672.00000 | 23.10475 | 39.46993 | -0.5279 | 6.73315 |
Maximum of Months | 744.00000 | 23.38886 | 59.87565 | 0.39430 | 11.63428 |
Report: OccupantComfortDataSummaryMonthly
For: DINING_FLR_6 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.29091 | 43.44030 | 0.31878 | 7.86093 |
February | 672.00000 | 23.48798 | 45.38132 | 0.38175 | 8.52263 |
March | 744.00000 | 23.45813 | 48.94148 | 0.40244 | 8.81777 |
April | 720.00000 | 23.54346 | 52.83816 | 0.46839 | 9.92954 |
May | 744.00000 | 23.53702 | 52.65334 | -0.4203 | 9.24126 |
June | 720.00000 | 23.51977 | 57.63012 | -0.3708 | 8.46940 |
July | 744.00000 | 23.52553 | 58.67640 | -0.3482 | 8.06727 |
August | 744.00000 | 23.49740 | 58.82017 | -0.3602 | 8.28955 |
September | 720.00000 | 23.46737 | 57.75014 | -0.3975 | 8.96472 |
October | 744.00000 | 23.42352 | 49.04819 | 0.42253 | 9.26658 |
November | 720.00000 | 23.44219 | 44.40315 | 0.36832 | 8.41688 |
December | 744.00000 | 23.34080 | 38.49305 | 0.29720 | 7.46953 |
Annual Sum or Average | 8760.00000 | 23.46060 | 50.68928 | 0.06143 | 8.60671 |
Minimum of Months | 672.00000 | 23.29091 | 38.49305 | -0.4203 | 7.46953 |
Maximum of Months | 744.00000 | 23.54346 | 58.82017 | 0.46839 | 9.92954 |
Report: OccupantComfortDataSummaryMonthly
For: KITCHEN_FLR_6 PEOPLE
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 744.00000 | 23.52208 | 41.81954 | 1.02430 | 31.30723 |
February | 672.00000 | 23.65260 | 43.77308 | 1.06636 | 32.23409 |
March | 744.00000 | 23.60543 | 47.18310 | 1.08231 | 33.29823 |
April | 720.00000 | 23.69331 | 51.25736 | 1.15793 | 35.81001 |
May | 744.00000 | 23.67418 | 51.15932 | 0.55571 | 17.92752 |
June | 720.00000 | 23.60879 | 56.21484 | 0.59352 | 19.06259 |
July | 744.00000 | 23.55288 | 57.39660 | 0.60840 | 19.98107 |
August | 744.00000 | 23.54436 | 57.42385 | 0.60554 | 20.01458 |
September | 720.00000 | 23.56271 | 56.17584 | 0.57406 | 19.02557 |
October | 744.00000 | 23.57663 | 47.65228 | 1.11607 | 34.39146 |
November | 720.00000 | 23.65286 | 42.86447 | 1.06911 | 32.31793 |
December | 744.00000 | 23.54819 | 37.06345 | 0.99895 | 30.13298 |
Annual Sum or Average | 8760.00000 | 23.59874 | 49.18264 | 0.86966 | 27.08954 |
Minimum of Months | 672.00000 | 23.52208 | 37.06345 | 0.55571 | 17.92752 |
Maximum of Months | 744.00000 | 23.69331 | 57.42385 | 1.15793 | 35.81001 |
Report: ChillerReportMonthly
For: COOLSYS1 CHILLER
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCHILLER ELECTRIC ENERGY [J] | CHILLER ELECTRIC POWER {Maximum}[W] | CHILLER ELECTRIC POWER {TIMESTAMP} | CHILLER ELECTRIC ENERGY {HOURS NON-ZERO} [HOURS] | CHILLER EVAPORATOR COOLING ENERGY [J] | CHILLER EVAPORATOR COOLING RATE [] | CHILLER CONDENSER HEAT TRANSFER ENERGY [J] | CHILLER COP [W/W] | CHILLER COP {Maximum}[W/W] | CHILLER COP {TIMESTAMP} | CHILLER PART LOAD RATIO [] | CHILLER PART LOAD RATIO [] | |
January | 0.419378E+11 | 85484.42 | 14-JAN-11:00 | 606.08 | 0.134484E+12 | 0.00 | 0.176421E+12 | 2.57 | 3.98 | 17-JAN-16:02 | 0.00 | 0.00 |
February | 0.285268E+11 | 81590.00 | 01-FEB-12:00 | 563.84 | 0.895493E+11 | 0.00 | 0.118076E+12 | 2.64 | 3.95 | 01-FEB-09:02 | 0.00 | 0.00 |
March | 0.271267E+11 | 92471.97 | 23-MAR-15:02 | 575.31 | 0.876926E+11 | 0.00 | 0.114819E+12 | 2.45 | 4.17 | 23-MAR-15:02 | 0.00 | 0.00 |
April | 0.539626E+11 | 92137.63 | 11-APR-15:02 | 693.44 | 0.174680E+12 | 0.00 | 0.228643E+12 | 3.05 | 4.05 | 14-APR-15:02 | 0.00 | 0.00 |
May | 0.591898E+11 | 91859.70 | 18-MAY-15:02 | 729.44 | 0.185985E+12 | 0.00 | 0.245175E+12 | 3.07 | 4.29 | 05-MAY-15:02 | 0.00 | 0.00 |
June | 0.999638E+11 | 108004.71 | 29-JUN-18:03 | 720.00 | 0.342682E+12 | 0.00 | 0.442645E+12 | 3.28 | 4.40 | 27-JUN-18:03 | 0.00 | 0.00 |
July | 0.166589E+12 | 150794.00 | 19-JUL-15:02 | 744.00 | 0.631981E+12 | 0.00 | 0.798570E+12 | 3.66 | 4.48 | 28-JUL-18:03 | 0.00 | 0.00 |
August | 0.180812E+12 | 158476.32 | 18-AUG-15:02 | 744.00 | 0.701137E+12 | 0.00 | 0.881949E+12 | 3.78 | 4.51 | 24-AUG-18:02 | 0.00 | 0.00 |
September | 0.125691E+12 | 164736.38 | 29-SEP-13:00 | 719.83 | 0.449027E+12 | 0.00 | 0.574718E+12 | 3.42 | 4.49 | 22-SEP-18:03 | 0.00 | 0.00 |
October | 0.129426E+12 | 182724.56 | 16-OCT-11:00 | 738.36 | 0.464968E+12 | 0.00 | 0.594394E+12 | 3.38 | 4.50 | 01-OCT-08:62 | 0.00 | 0.00 |
November | 0.462797E+11 | 97161.73 | 19-NOV-09:02 | 655.83 | 0.148266E+12 | 0.00 | 0.194545E+12 | 2.87 | 3.98 | 19-NOV-16:01 | 0.00 | 0.00 |
December | 0.456203E+11 | 94278.38 | 05-DEC-09:02 | 619.49 | 0.149534E+12 | 0.00 | 0.195155E+12 | 2.65 | 4.00 | 05-DEC-19:02 | 0.00 | 0.00 |
Annual Sum or Average | 0.100513E+13 | 8109.64 | 0.355998E+13 | 0.456511E+13 | 3.07 | |||||||
Minimum of Months | 0.271267E+11 | 81590.00 | 563.84 | 0.876926E+11 | 0.00 | 0.114819E+12 | 2.45 | 3.95 | 0.00 | 0.00 | ||
Maximum of Months | 0.180812E+12 | 182724.56 | 744.00 | 0.701137E+12 | 0.00 | 0.881949E+12 | 3.78 | 4.51 | 0.00 | 0.00 |
Report: BoilerReportMonthly
For: HEATSYS1 BOILER
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportBOILER HEATING ENERGY [J] | BOILER GAS CONSUMPTION [] | BOILER HEATING ENERGY {HOURS NON-ZERO} [HOURS] | BOILER HEATING RATE {Maximum}[W] | BOILER HEATING RATE {TIMESTAMP} | BOILER GAS CONSUMPTION RATE [] | BOILER INLET TEMPERATURE [C] | BOILER OUTLET TEMPERATURE [C] | BOILER MASS FLOW RATE [kg/s] | BOILER ANCILLARY ELECTRIC POWER [W] | BOILER PART LOAD RATIO [] | BOILER PART LOAD RATIO {Maximum}[] | BOILER PART LOAD RATIO {TIMESTAMP} | |
January | 0.111501E+12 | 0.00 | 719.73 | 169852.34 | 08-JAN-07:00 | 0.00 | 45.86 | 56.87 | 1.06 | 0.00 | 0.16 | 0.64 | 08-JAN-07:00 |
February | 0.853490E+11 | 0.00 | 659.89 | 128646.18 | 05-FEB-06:00 | 0.00 | 45.09 | 57.07 | 0.84 | 0.00 | 0.13 | 0.48 | 05-FEB-06:00 |
March | 0.117976E+12 | 0.00 | 741.02 | 151682.65 | 30-MAR-03:00 | 0.00 | 44.56 | 57.24 | 1.07 | 0.00 | 0.16 | 0.57 | 30-MAR-03:00 |
April | 0.487796E+11 | 0.00 | 696.82 | 114670.89 | 01-APR-05:00 | 0.00 | 41.89 | 56.71 | 0.37 | 0.00 | 0.07 | 0.43 | 01-APR-05:00 |
May | 0.451479E+11 | 0.00 | 700.86 | 103954.99 | 14-MAY-04:50 | 0.00 | 41.74 | 56.26 | 0.34 | 0.00 | 0.06 | 0.39 | 14-MAY-04:50 |
June | 0.139596E+11 | 0.00 | 612.11 | 70504.01 | 13-JUN-04:00 | 0.00 | 41.22 | 54.77 | 0.09 | 0.00 | 0.02 | 0.26 | 13-JUN-04:00 |
July | 0.873790E+10 | 0.00 | 595.00 | 42930.66 | 11-JUL-15:05 | 0.00 | 41.27 | 53.99 | 0.05 | 0.00 | 0.01 | 0.16 | 11-JUL-15:05 |
August | 0.793882E+10 | 0.00 | 591.15 | 41888.38 | 14-AUG-08:05 | 0.00 | 41.67 | 54.01 | 0.05 | 0.00 | 0.01 | 0.16 | 14-AUG-08:05 |
September | 0.996797E+10 | 0.00 | 607.07 | 68428.22 | 20-SEP-04:00 | 0.00 | 41.96 | 54.76 | 0.07 | 0.00 | 0.01 | 0.26 | 20-SEP-04:00 |
October | 0.212725E+11 | 0.00 | 611.83 | 96186.00 | 28-OCT-05:00 | 0.00 | 42.68 | 54.61 | 0.16 | 0.00 | 0.03 | 0.36 | 28-OCT-05:00 |
November | 0.708120E+11 | 0.00 | 692.31 | 116248.50 | 24-NOV-04:00 | 0.00 | 44.94 | 56.80 | 0.65 | 0.00 | 0.10 | 0.44 | 24-NOV-04:00 |
December | 0.107820E+12 | 0.00 | 724.56 | 132518.10 | 24-DEC-04:00 | 0.00 | 46.17 | 56.99 | 1.02 | 0.00 | 0.15 | 0.50 | 24-DEC-04:00 |
Annual Sum or Average | 0.649263E+12 | 7952.36 | 43.25 | 55.83 | 0.48 | 0.00 | 0.08 | ||||||
Minimum of Months | 0.793882E+10 | 0.00 | 591.15 | 41888.38 | 0.00 | 41.22 | 53.99 | 0.05 | 0.00 | 0.01 | 0.16 | ||
Maximum of Months | 0.117976E+12 | 0.00 | 741.02 | 169852.34 | 0.00 | 46.17 | 57.24 | 1.07 | 0.00 | 0.16 | 0.64 |
Report: DXReportMonthly
For: ROOM_1_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.112253E+10 | 0.00 | 311.93 | 0.706986E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11224.91 | 14-JAN-16:01 | 11224.91 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.105129E+10 | 0.00 | 235.09 | 0.686036E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10990.52 | 03-FEB-16:01 | 10990.52 | 03-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.111418E+10 | 0.00 | 236.74 | 0.665597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11119.15 | 10-MAR-16:01 | 11119.15 | 10-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.230488E+10 | 0.00 | 421.46 | 0.129402E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11217.95 | 01-APR-15:02 | 11217.95 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.210094E+10 | 0.00 | 427.36 | 0.113766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11158.24 | 06-MAY-15:02 | 10606.74 | 24-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.320116E+10 | 0.00 | 515.36 | 0.163581E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11596.82 | 28-JUN-15:02 | 10586.40 | 20-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.485014E+10 | 0.00 | 590.20 | 0.246043E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12356.09 | 30-JUL-08:62 | 10813.06 | 19-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.495852E+10 | 0.00 | 596.75 | 0.249051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12478.36 | 19-AUG-08:62 | 10914.27 | 19-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.370394E+10 | 0.00 | 562.51 | 0.187970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12346.42 | 21-SEP-15:02 | 10887.21 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.348901E+10 | 0.00 | 539.66 | 0.228133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12492.66 | 01-OCT-08:62 | 11597.46 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.154491E+10 | 0.00 | 381.03 | 0.935850E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11292.18 | 19-NOV-09:02 | 11292.18 | 19-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 0.133407E+10 | 0.00 | 334.79 | 0.107692E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11214.31 | 05-DEC-16:01 | 11214.31 | 05-DEC-16:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.307756E+11 | 5152.88 | 0.172508E+11 | ||||||||||||
Minimum of Months | 0.105129E+10 | 0.00 | 235.09 | 0.665597E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10990.52 | 10586.40 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.495852E+10 | 0.00 | 596.75 | 0.249051E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12492.66 | 11597.46 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_2_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.225602E+09 | 0.00 | 103.48 | 0.139843E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10921.18 | 14-JAN-16:01 | 10921.18 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.363653E+09 | 0.00 | 122.13 | 0.233642E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10733.03 | 03-FEB-16:01 | 10733.03 | 03-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.617842E+09 | 0.00 | 155.95 | 0.368058E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11068.54 | 23-MAR-15:02 | 10858.33 | 10-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.184807E+10 | 0.00 | 365.61 | 0.103316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11068.20 | 11-APR-15:02 | 10953.25 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.201094E+10 | 0.00 | 418.25 | 0.109596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10894.45 | 06-MAY-15:02 | 10362.47 | 24-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.324760E+10 | 0.00 | 516.36 | 0.168150E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11342.98 | 28-JUN-15:02 | 10338.07 | 20-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.481658E+10 | 0.00 | 587.37 | 0.246267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12068.33 | 30-JUL-08:62 | 10550.25 | 19-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.452174E+10 | 0.00 | 581.64 | 0.223551E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12190.78 | 19-AUG-08:62 | 10545.71 | 19-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.281403E+10 | 0.00 | 528.85 | 0.135917E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12104.57 | 21-SEP-15:02 | 10480.94 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.220316E+10 | 0.00 | 445.84 | 0.134775E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12209.46 | 01-OCT-08:62 | 11325.72 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.379800E+09 | 0.00 | 181.71 | 0.208144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10801.77 | 10-NOV-16:02 | 10476.83 | 23-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 0.225785E+09 | 0.00 | 103.41 | 0.191293E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10951.38 | 05-DEC-16:01 | 10951.38 | 05-DEC-16:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.232748E+11 | 4110.60 | 0.123567E+11 | ||||||||||||
Minimum of Months | 0.225602E+09 | 0.00 | 103.41 | 0.139843E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10733.03 | 10338.07 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.481658E+10 | 0.00 | 587.37 | 0.246267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12209.46 | 11325.72 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.175261E+11 | 0.00 | 363.11 | 0.149334E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 36775.66 | 14-JAN-12:40 | 36775.66 | 14-JAN-12:40 | 0.00 | 0.00 | 0.00 |
February | 0.106611E+11 | 0.00 | 250.19 | 0.910015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 32816.28 | 02-FEB-12:40 | 32816.28 | 02-FEB-12:40 | 0.00 | 0.00 | 0.00 |
March | 0.366643E+10 | 0.00 | 152.40 | 0.216507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20698.53 | 11-MAR-13:10 | 20698.53 | 11-MAR-13:10 | 0.00 | 0.00 | 0.00 |
April | 0.151425E+10 | 0.00 | 103.82 | 0.455689E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 11281.76 | 08-APR-12:40 | 4936.79 | 08-APR-12:40 | 0.00 | 0.00 | 0.00 |
May | 27903100.76 | 0.00 | 6.33 | 3484826.03 | 0.00 | 0.00 | 0.00 | 0.00 | 2056.45 | 04-MAY-13:30 | 308.45 | 04-MAY-13:30 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.856821E+09 | 0.00 | 93.53 | 0.155997E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9441.41 | 31-JUL-17:17 | 2597.09 | 31-JUL-17:20 | 0.00 | 0.00 | 0.00 |
August | 0.379931E+10 | 0.00 | 251.67 | 0.991999E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 14371.28 | 18-AUG-15:10 | 5924.60 | 18-AUG-15:10 | 0.00 | 0.00 | 0.00 |
September | 0.879691E+10 | 0.00 | 280.22 | 0.474460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33840.17 | 30-SEP-12:10 | 32496.02 | 29-SEP-13:30 | 0.00 | 0.00 | 0.00 |
October | 0.195239E+11 | 0.00 | 403.26 | 0.156636E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 42890.37 | 16-OCT-12:10 | 42890.37 | 16-OCT-12:10 | 0.00 | 0.00 | 0.00 |
November | 0.187221E+11 | 0.00 | 383.59 | 0.156220E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 39809.27 | 19-NOV-12:30 | 39809.27 | 19-NOV-12:30 | 0.00 | 0.00 | 0.00 |
December | 0.213969E+11 | 0.00 | 395.43 | 0.196028E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37656.80 | 19-DEC-13:00 | 37656.80 | 19-DEC-13:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.106492E+12 | 2683.55 | 0.834388E+11 | ||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.213969E+11 | 0.00 | 403.26 | 0.196028E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 42890.37 | 42890.37 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.692624E+10 | 0.00 | 314.27 | 0.355905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 59645.18 | 15-JAN-09:02 | 59645.18 | 15-JAN-09:02 | 0.00 | 0.00 | 0.00 |
February | 0.780027E+10 | 0.00 | 358.62 | 0.403230E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60415.54 | 13-FEB-19:03 | 55837.83 | 20-FEB-09:02 | 0.00 | 0.00 | 0.00 |
March | 0.968705E+10 | 0.00 | 386.35 | 0.486864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58073.33 | 23-MAR-15:02 | 57273.63 | 11-MAR-09:02 | 0.00 | 0.00 | 0.00 |
April | 0.170558E+11 | 0.00 | 490.75 | 0.856090E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60438.15 | 26-APR-08:62 | 57345.15 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.206503E+11 | 0.00 | 510.98 | 0.112126E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 60179.67 | 06-MAY-08:62 | 56607.04 | 26-MAY-18:02 | 0.00 | 0.00 | 0.00 |
June | 0.283751E+11 | 0.00 | 507.08 | 0.148923E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 65515.67 | 29-JUN-18:02 | 55992.16 | 30-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.371320E+11 | 0.00 | 525.51 | 0.196580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 73712.54 | 18-JUL-18:02 | 57822.23 | 19-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.349077E+11 | 0.00 | 524.47 | 0.174647E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 70613.83 | 19-AUG-08:62 | 57440.81 | 19-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.244418E+11 | 0.00 | 505.40 | 0.114037E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 67973.92 | 22-SEP-08:62 | 59393.28 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.221874E+11 | 0.00 | 512.12 | 0.134603E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 71689.60 | 01-OCT-08:62 | 65131.48 | 15-OCT-08:62 | 0.00 | 0.00 | 0.00 |
November | 0.937701E+10 | 0.00 | 404.06 | 0.507482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61448.23 | 19-NOV-09:02 | 61448.23 | 19-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 0.616996E+10 | 0.00 | 313.64 | 0.428585E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 59710.91 | 05-DEC-09:02 | 59710.91 | 05-DEC-09:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.224711E+12 | 5353.25 | 0.118473E+12 | ||||||||||||
Minimum of Months | 0.616996E+10 | 0.00 | 313.64 | 0.355905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 58073.33 | 55837.83 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.371320E+11 | 0.00 | 525.51 | 0.196580E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 73712.54 | 65131.48 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_5_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.122199E+10 | 0.00 | 294.83 | 0.861722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9717.58 | 14-JAN-16:01 | 9717.58 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.963673E+09 | 0.00 | 213.99 | 0.677259E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9584.62 | 01-FEB-09:02 | 9584.62 | 01-FEB-09:02 | 0.00 | 0.00 | 0.00 |
March | 0.108255E+10 | 0.00 | 244.81 | 0.663457E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9817.65 | 23-MAR-15:02 | 9623.36 | 10-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.202208E+10 | 0.00 | 378.77 | 0.116900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9770.81 | 30-APR-15:02 | 9545.92 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.174723E+10 | 0.00 | 373.55 | 0.947063E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9807.22 | 03-MAY-08:62 | 9286.42 | 24-MAY-08:62 | 0.00 | 0.00 | 0.00 |
June | 0.256691E+10 | 0.00 | 448.78 | 0.131688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10282.76 | 29-JUN-08:62 | 8997.08 | 03-JUN-08:62 | 0.00 | 0.00 | 0.00 |
July | 0.426282E+10 | 0.00 | 595.22 | 0.219364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11052.44 | 31-JUL-15:02 | 9104.10 | 10-JUL-08:62 | 0.00 | 0.00 | 0.00 |
August | 0.460959E+10 | 0.00 | 630.21 | 0.234886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10886.89 | 17-AUG-15:02 | 9172.07 | 19-AUG-18:02 | 0.00 | 0.00 | 0.00 |
September | 0.297917E+10 | 0.00 | 538.77 | 0.153462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10775.91 | 09-SEP-08:62 | 9295.35 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.322497E+10 | 0.00 | 541.47 | 0.219072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10811.74 | 01-OCT-08:62 | 10046.01 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.140600E+10 | 0.00 | 334.12 | 0.964159E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9824.84 | 19-NOV-09:02 | 9824.84 | 19-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 0.132789E+10 | 0.00 | 327.34 | 0.113923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9818.38 | 05-DEC-09:02 | 9818.38 | 05-DEC-09:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.274149E+11 | 4921.85 | 0.160066E+11 | ||||||||||||
Minimum of Months | 0.963673E+09 | 0.00 | 213.99 | 0.663457E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9584.62 | 8997.08 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.460959E+10 | 0.00 | 630.21 | 0.234886E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11052.44 | 10046.01 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_6_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.348531E+09 | 0.00 | 122.63 | 0.215745E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9404.32 | 21-JAN-09:02 | 8772.93 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.334567E+09 | 0.00 | 119.58 | 0.227003E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9115.04 | 01-FEB-09:02 | 9115.04 | 01-FEB-09:02 | 0.00 | 0.00 | 0.00 |
March | 0.603417E+09 | 0.00 | 161.96 | 0.345017E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9439.75 | 23-MAR-15:02 | 8979.78 | 11-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.161155E+10 | 0.00 | 317.68 | 0.918073E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9690.22 | 27-APR-08:62 | 9186.42 | 26-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.167016E+10 | 0.00 | 361.33 | 0.907250E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9731.36 | 03-MAY-08:62 | 9194.73 | 24-MAY-08:62 | 0.00 | 0.00 | 0.00 |
June | 0.261244E+10 | 0.00 | 448.76 | 0.135157E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10179.12 | 29-JUN-08:62 | 8896.88 | 03-JUN-08:62 | 0.00 | 0.00 | 0.00 |
July | 0.422238E+10 | 0.00 | 585.72 | 0.218439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10957.86 | 31-JUL-15:02 | 8918.24 | 04-JUL-08:62 | 0.00 | 0.00 | 0.00 |
August | 0.417053E+10 | 0.00 | 581.29 | 0.210885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10976.15 | 17-AUG-15:02 | 9024.17 | 19-AUG-18:02 | 0.00 | 0.00 | 0.00 |
September | 0.215238E+10 | 0.00 | 460.51 | 0.106113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10737.51 | 09-SEP-08:62 | 9151.94 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.194549E+10 | 0.00 | 415.89 | 0.124262E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10717.61 | 01-OCT-08:62 | 9946.71 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.409555E+09 | 0.00 | 154.71 | 0.260648E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9727.39 | 19-NOV-09:02 | 9727.39 | 19-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 0.315095E+09 | 0.00 | 114.15 | 0.272762E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9720.63 | 05-DEC-09:02 | 9720.63 | 05-DEC-09:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.203961E+11 | 3844.21 | 0.110951E+11 | ||||||||||||
Minimum of Months | 0.315095E+09 | 0.00 | 114.15 | 0.215745E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9115.04 | 8772.93 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.422238E+10 | 0.00 | 585.72 | 0.218439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10976.15 | 9946.71 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_1_FLR_6 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.277085E+09 | 0.00 | 260.46 | 0.182602E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2904.97 | 21-JAN-09:02 | 2898.93 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.265385E+09 | 0.00 | 203.27 | 0.182587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2838.49 | 03-FEB-16:01 | 2838.49 | 03-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.300906E+09 | 0.00 | 208.64 | 0.191263E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2871.60 | 10-MAR-16:01 | 2871.60 | 10-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.647849E+09 | 0.00 | 385.70 | 0.391631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2971.27 | 26-APR-08:62 | 2897.25 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.593437E+09 | 0.00 | 393.64 | 0.347167E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2936.99 | 03-MAY-08:62 | 2744.13 | 17-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.933390E+09 | 0.00 | 506.76 | 0.515551E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3038.70 | 30-JUN-08:62 | 2799.46 | 30-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.144124E+10 | 0.00 | 630.39 | 0.782567E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3291.80 | 23-JUL-08:62 | 2883.26 | 19-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.146211E+10 | 0.00 | 640.70 | 0.777247E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3354.92 | 19-AUG-08:62 | 2869.84 | 18-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.103915E+10 | 0.00 | 577.43 | 0.564059E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3214.02 | 09-SEP-08:62 | 2792.16 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.960232E+09 | 0.00 | 524.06 | 0.648355E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3341.87 | 01-OCT-08:62 | 2995.17 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.388021E+09 | 0.00 | 326.29 | 0.244936E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2889.15 | 19-NOV-09:02 | 2889.15 | 19-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 0.326169E+09 | 0.00 | 285.27 | 0.271561E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2896.27 | 05-DEC-16:01 | 2896.27 | 05-DEC-16:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.863498E+10 | 4942.59 | 0.509953E+10 | ||||||||||||
Minimum of Months | 0.265385E+09 | 0.00 | 203.27 | 0.182587E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2838.49 | 2744.13 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.146211E+10 | 0.00 | 640.70 | 0.782567E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3354.92 | 2995.17 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_2_FLR_6 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 54664804.30 | 0.00 | 79.07 | 36359511.43 | 0.00 | 0.00 | 0.00 | 0.00 | 2831.44 | 14-JAN-16:01 | 2831.44 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 90426369.58 | 0.00 | 95.14 | 63644277.53 | 0.00 | 0.00 | 0.00 | 0.00 | 2772.22 | 03-FEB-16:01 | 2772.22 | 03-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.168297E+09 | 0.00 | 129.09 | 0.107380E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2818.98 | 23-MAR-15:02 | 2804.60 | 10-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.524168E+09 | 0.00 | 328.05 | 0.315353E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2898.22 | 26-APR-08:62 | 2829.54 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.570329E+09 | 0.00 | 382.86 | 0.336538E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2859.86 | 03-MAY-08:62 | 2698.01 | 02-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.946106E+09 | 0.00 | 508.54 | 0.529544E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2961.26 | 30-JUN-08:62 | 2731.54 | 30-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.143189E+10 | 0.00 | 625.44 | 0.784272E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3218.94 | 23-JUL-08:62 | 2817.95 | 19-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.134042E+10 | 0.00 | 613.77 | 0.709538E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3280.20 | 19-AUG-08:62 | 2832.40 | 17-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.791893E+09 | 0.00 | 514.93 | 0.415456E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3132.49 | 09-SEP-08:62 | 2740.11 | 30-SEP-18:02 | 0.00 | 0.00 | 0.00 |
October | 0.611117E+09 | 0.00 | 417.87 | 0.388789E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3272.37 | 01-OCT-08:62 | 2925.39 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 92006801.71 | 0.00 | 130.54 | 54924289.66 | 0.00 | 0.00 | 0.00 | 0.00 | 2791.18 | 10-NOV-16:02 | 2733.04 | 27-NOV-16:01 | 0.00 | 0.00 | 0.00 |
December | 56436510.45 | 0.00 | 69.30 | 49181093.62 | 0.00 | 0.00 | 0.00 | 0.00 | 2828.64 | 05-DEC-16:01 | 2828.64 | 05-DEC-16:01 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.667775E+10 | 3894.59 | 0.379098E+10 | ||||||||||||
Minimum of Months | 54664804.30 | 0.00 | 69.30 | 36359511.43 | 0.00 | 0.00 | 0.00 | 0.00 | 2772.22 | 2698.01 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.143189E+10 | 0.00 | 625.44 | 0.784272E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3280.20 | 2925.39 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.603821E+10 | 0.00 | 522.14 | 0.493697E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12618.53 | 14-JAN-16:01 | 12618.53 | 14-JAN-16:01 | 0.00 | 0.00 | 0.00 |
February | 0.381126E+10 | 0.00 | 404.95 | 0.296771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12356.08 | 03-FEB-16:01 | 12356.08 | 03-FEB-16:01 | 0.00 | 0.00 | 0.00 |
March | 0.293767E+10 | 0.00 | 386.98 | 0.186567E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12500.16 | 10-MAR-16:01 | 12500.16 | 10-MAR-16:01 | 0.00 | 0.00 | 0.00 |
April | 0.323370E+10 | 0.00 | 489.98 | 0.174589E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12786.43 | 30-APR-15:02 | 12611.40 | 01-APR-15:02 | 0.00 | 0.00 | 0.00 |
May | 0.204645E+10 | 0.00 | 396.64 | 0.941322E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12574.86 | 04-MAY-15:02 | 12074.50 | 03-MAY-15:02 | 0.00 | 0.00 | 0.00 |
June | 0.306842E+10 | 0.00 | 469.03 | 0.136132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13325.67 | 29-JUN-18:02 | 11652.85 | 30-JUN-15:02 | 0.00 | 0.00 | 0.00 |
July | 0.531312E+10 | 0.00 | 557.93 | 0.253168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14823.78 | 18-JUL-18:02 | 11756.87 | 19-JUL-15:02 | 0.00 | 0.00 | 0.00 |
August | 0.661199E+10 | 0.00 | 628.93 | 0.325427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14248.28 | 19-AUG-08:62 | 12061.56 | 19-AUG-15:02 | 0.00 | 0.00 | 0.00 |
September | 0.647149E+10 | 0.00 | 617.82 | 0.356354E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13681.88 | 21-SEP-15:02 | 12113.08 | 11-SEP-15:02 | 0.00 | 0.00 | 0.00 |
October | 0.815514E+10 | 0.00 | 621.56 | 0.612149E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14276.39 | 01-OCT-08:62 | 13037.61 | 16-OCT-15:02 | 0.00 | 0.00 | 0.00 |
November | 0.617050E+10 | 0.00 | 552.84 | 0.484881E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12747.17 | 19-NOV-09:02 | 12747.17 | 19-NOV-09:02 | 0.00 | 0.00 | 0.00 |
December | 0.666546E+10 | 0.00 | 532.37 | 0.593634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12738.31 | 05-DEC-09:02 | 12738.31 | 05-DEC-09:02 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.605234E+11 | 6181.18 | 0.400750E+11 | ||||||||||||
Minimum of Months | 0.204645E+10 | 0.00 | 386.98 | 0.941322E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12356.08 | 11652.85 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.815514E+10 | 0.00 | 628.93 | 0.612149E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14823.78 | 13037.61 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: VAV WITH REHEAT_COOLC
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.826818E+11 | 0.00 | 335.50 | 0.813995E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 220307.08 | 14-JAN-11:50 | 220307.08 | 14-JAN-11:50 | 0.00 | 0.00 | 0.00 |
February | 0.521232E+11 | 0.00 | 278.67 | 0.490111E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 213797.68 | 01-FEB-12:00 | 213797.68 | 01-FEB-12:00 | 0.00 | 0.00 | 0.00 |
March | 0.546345E+11 | 0.00 | 248.17 | 0.507150E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 225052.63 | 23-MAR-15:03 | 187388.31 | 11-MAR-11:50 | 0.00 | 0.00 | 0.00 |
April | 0.119133E+12 | 0.00 | 402.17 | 0.110144E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 271622.90 | 26-APR-11:00 | 227867.78 | 26-APR-13:00 | 0.00 | 0.00 | 0.00 |
May | 0.128423E+12 | 0.00 | 495.00 | 0.123174E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 191738.81 | 04-MAY-13:00 | 184114.90 | 04-MAY-12:00 | 0.00 | 0.00 | 0.00 |
June | 0.252532E+12 | 0.00 | 665.67 | 0.195867E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 334048.38 | 29-JUN-11:00 | 202376.14 | 29-JUN-10:50 | 0.00 | 0.00 | 0.00 |
July | 0.484291E+12 | 0.00 | 740.83 | 0.285666E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 415998.57 | 19-JUL-12:00 | 250047.75 | 19-JUL-10:50 | 0.00 | 0.00 | 0.00 |
August | 0.542108E+12 | 0.00 | 744.00 | 0.296186E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 423520.61 | 14-AUG-10:50 | 250084.57 | 14-AUG-10:50 | 0.00 | 0.00 | 0.00 |
September | 0.337646E+12 | 0.00 | 695.67 | 0.230316E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 450007.81 | 22-SEP-12:00 | 372158.05 | 29-SEP-10:50 | 0.00 | 0.00 | 0.00 |
October | 0.340060E+12 | 0.00 | 641.67 | 0.259305E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 410847.62 | 01-OCT-12:00 | 390841.31 | 16-OCT-10:50 | 0.00 | 0.00 | 0.00 |
November | 0.907051E+11 | 0.00 | 381.83 | 0.857472E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 233998.42 | 19-NOV-13:00 | 233998.42 | 19-NOV-13:00 | 0.00 | 0.00 | 0.00 |
December | 0.917404E+11 | 0.00 | 332.00 | 0.916011E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 216762.41 | 16-DEC-13:00 | 216762.41 | 16-DEC-13:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.257608E+13 | 5961.17 | 0.185913E+13 | ||||||||||||
Minimum of Months | 0.521232E+11 | 0.00 | 248.17 | 0.490111E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 191738.81 | 184114.90 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.542108E+12 | 0.00 | 744.00 | 0.296186E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 450007.81 | 390841.31 | 0.00 | 0.00 | 0.00 |
Report: DXReportMonthly
For: FLR_3_DOAS_COOLC
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL RUNTIME FRACTION [] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE [] | COOLING COIL ELECTRIC POWER [] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER [] | |
January | 0.112658E+11 | 0.00 | 275.67 | 0.111536E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 34743.62 | 13-JAN-14:00 | 34743.62 | 13-JAN-14:00 | 0.00 | 0.00 | 0.00 |
February | 0.622464E+10 | 0.00 | 211.33 | 0.601657E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34694.04 | 01-FEB-12:00 | 34694.04 | 01-FEB-12:00 | 0.00 | 0.00 | 0.00 |
March | 0.716323E+10 | 0.00 | 192.33 | 0.662317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37275.62 | 23-MAR-15:00 | 29764.49 | 11-MAR-13:00 | 0.00 | 0.00 | 0.00 |
April | 0.167384E+11 | 0.00 | 332.17 | 0.156668E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 44342.00 | 26-APR-11:00 | 37310.83 | 26-APR-13:00 | 0.00 | 0.00 | 0.00 |
May | 0.173875E+11 | 0.00 | 414.50 | 0.169834E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 31869.69 | 04-MAY-13:10 | 29918.36 | 04-MAY-12:00 | 0.00 | 0.00 | 0.00 |
June | 0.349109E+11 | 0.00 | 609.17 | 0.277543E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 54358.03 | 29-JUN-11:00 | 32597.26 | 29-JUN-11:00 | 0.00 | 0.00 | 0.00 |
July | 0.710409E+11 | 0.00 | 736.00 | 0.427184E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 65145.73 | 31-JUL-12:20 | 40003.75 | 19-JUL-11:00 | 0.00 | 0.00 | 0.00 |
August | 0.800063E+11 | 0.00 | 737.50 | 0.445962E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 65121.07 | 14-AUG-11:00 | 39046.50 | 18-AUG-12:00 | 0.00 | 0.00 | 0.00 |
September | 0.471891E+11 | 0.00 | 667.50 | 0.333172E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 67382.89 | 22-SEP-12:00 | 59323.38 | 29-SEP-13:00 | 0.00 | 0.00 | 0.00 |
October | 0.517453E+11 | 0.00 | 612.50 | 0.393188E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 63638.29 | 01-OCT-12:00 | 61690.14 | 16-OCT-11:00 | 0.00 | 0.00 | 0.00 |
November | 0.115868E+11 | 0.00 | 320.50 | 0.113554E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 37149.32 | 19-NOV-13:00 | 37149.32 | 19-NOV-13:00 | 0.00 | 0.00 | 0.00 |
December | 0.131181E+11 | 0.00 | 279.83 | 0.131057E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 34602.16 | 16-DEC-13:00 | 34602.16 | 16-DEC-13:00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.368377E+12 | 5389.00 | 0.268610E+12 | ||||||||||||
Minimum of Months | 0.622464E+10 | 0.00 | 192.33 | 0.601657E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31869.69 | 29764.49 | 0.00 | 0.00 | 0.00 | ||
Maximum of Months | 0.800063E+11 | 0.00 | 737.50 | 0.445962E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 67382.89 | 61690.14 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 691.03 | 507.37 | 183.66 | 981.86 | 358.16 | 0.00 | 0.00 | 744.00 |
February | 545.81 | 337.77 | 208.04 | 713.97 | 326.63 | 0.00 | 0.00 | 672.00 |
March | 435.17 | 211.95 | 223.22 | 530.24 | 339.89 | 0.00 | 0.00 | 744.00 |
April | 363.79 | 140.51 | 223.28 | 419.24 | 263.04 | 0.00 | 0.00 | 720.00 |
May | 256.31 | 30.93 | 225.38 | 255.38 | 232.89 | 0.00 | 0.00 | 744.00 |
June | 224.85 | 13.08 | 211.77 | 245.21 | 167.08 | 0.00 | 0.00 | 720.00 |
July | 237.09 | 25.22 | 211.88 | 287.09 | 138.22 | 0.00 | 0.00 | 744.00 |
August | 304.55 | 94.52 | 210.03 | 390.07 | 145.99 | 0.00 | 0.00 | 744.00 |
September | 418.30 | 207.74 | 210.56 | 574.55 | 181.59 | 0.00 | 0.00 | 720.00 |
October | 547.96 | 368.02 | 179.95 | 823.92 | 210.02 | 0.00 | 0.00 | 744.00 |
November | 665.72 | 471.73 | 193.99 | 941.08 | 320.73 | 0.00 | 0.00 | 720.00 |
December | 739.48 | 563.54 | 175.93 | 1063.27 | 359.32 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 452.12 | 247.39 | 204.72 | 601.86 | 253.26 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 224.85 | 13.08 | 175.93 | 245.21 | 138.22 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 739.48 | 563.54 | 225.38 | 1063.27 | 359.32 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CAFE_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1945.91 | 1428.72 | 517.18 | 2732.15 | 1088.28 | 0.00 | 0.00 | 744.00 |
February | 1536.96 | 951.13 | 585.83 | 1976.58 | 1009.77 | 0.00 | 0.00 | 672.00 |
March | 1225.42 | 596.84 | 628.58 | 1464.23 | 1037.78 | 0.00 | 0.00 | 744.00 |
April | 1024.41 | 395.67 | 628.74 | 1151.94 | 823.87 | 0.00 | 0.00 | 720.00 |
May | 721.76 | 87.11 | 634.65 | 690.48 | 729.68 | 0.00 | 0.00 | 744.00 |
June | 633.15 | 36.82 | 596.33 | 659.89 | 537.43 | 0.00 | 0.00 | 720.00 |
July | 667.64 | 71.00 | 596.64 | 778.03 | 448.82 | 0.00 | 0.00 | 744.00 |
August | 857.59 | 266.17 | 591.42 | 1071.81 | 476.10 | 0.00 | 0.00 | 744.00 |
September | 1177.91 | 584.99 | 592.92 | 1593.09 | 584.72 | 0.00 | 0.00 | 720.00 |
October | 1543.03 | 1036.32 | 506.72 | 2292.48 | 666.57 | 0.00 | 0.00 | 744.00 |
November | 1874.62 | 1328.36 | 546.26 | 2612.57 | 993.05 | 0.00 | 0.00 | 720.00 |
December | 2082.32 | 1586.90 | 495.41 | 2958.36 | 1094.88 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1273.13 | 696.64 | 576.49 | 1664.34 | 789.73 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 633.15 | 36.82 | 495.41 | 659.89 | 448.82 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 2082.32 | 1586.90 | 634.65 | 2958.36 | 1094.88 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LOBBY_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 2527.84 | 1855.99 | 671.85 | 3646.19 | 1432.07 | 0.00 | 0.00 | 744.00 |
February | 1996.60 | 1235.57 | 761.03 | 2631.84 | 1350.90 | 0.00 | 0.00 | 672.00 |
March | 1591.89 | 775.33 | 816.56 | 1943.96 | 1403.06 | 0.00 | 0.00 | 744.00 |
April | 1330.77 | 514.00 | 816.77 | 1528.07 | 1113.64 | 0.00 | 0.00 | 720.00 |
May | 937.61 | 113.16 | 824.45 | 908.09 | 1000.33 | 0.00 | 0.00 | 744.00 |
June | 822.50 | 47.84 | 774.67 | 871.13 | 735.52 | 0.00 | 0.00 | 720.00 |
July | 867.30 | 92.24 | 775.06 | 1033.74 | 609.77 | 0.00 | 0.00 | 744.00 |
August | 1114.06 | 345.77 | 768.29 | 1429.99 | 635.05 | 0.00 | 0.00 | 744.00 |
September | 1530.17 | 759.93 | 770.23 | 2127.48 | 772.78 | 0.00 | 0.00 | 720.00 |
October | 2004.49 | 1346.23 | 658.25 | 3064.89 | 866.42 | 0.00 | 0.00 | 744.00 |
November | 2435.24 | 1725.62 | 709.62 | 3483.55 | 1308.78 | 0.00 | 0.00 | 720.00 |
December | 2705.05 | 2061.48 | 643.57 | 3949.17 | 1438.69 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1653.86 | 904.97 | 748.90 | 2217.14 | 1053.96 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 822.50 | 47.84 | 643.57 | 871.13 | 609.77 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 2705.05 | 2061.48 | 824.45 | 3949.17 | 1438.69 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 136.35 | 100.11 | 36.24 | 196.39 | 70.55 | 0.00 | 0.00 | 744.00 |
February | 107.70 | 66.65 | 41.05 | 141.24 | 64.92 | 0.00 | 0.00 | 672.00 |
March | 85.87 | 41.82 | 44.04 | 103.95 | 69.39 | 0.00 | 0.00 | 744.00 |
April | 71.78 | 27.72 | 44.06 | 80.98 | 54.15 | 0.00 | 0.00 | 720.00 |
May | 50.57 | 6.10 | 44.47 | 47.79 | 48.75 | 0.00 | 0.00 | 744.00 |
June | 44.37 | 2.58 | 41.79 | 45.65 | 34.77 | 0.00 | 0.00 | 720.00 |
July | 46.78 | 4.98 | 41.81 | 54.20 | 28.45 | 0.00 | 0.00 | 744.00 |
August | 60.09 | 18.65 | 41.44 | 75.46 | 29.37 | 0.00 | 0.00 | 744.00 |
September | 82.54 | 40.99 | 41.55 | 113.00 | 35.84 | 0.00 | 0.00 | 720.00 |
October | 108.12 | 72.62 | 35.51 | 164.65 | 39.47 | 0.00 | 0.00 | 744.00 |
November | 131.36 | 93.08 | 38.28 | 187.67 | 62.52 | 0.00 | 0.00 | 720.00 |
December | 145.91 | 111.20 | 34.71 | 212.87 | 70.02 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 89.21 | 48.81 | 40.40 | 118.60 | 50.61 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 44.37 | 2.58 | 34.71 | 45.65 | 28.45 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 145.91 | 111.20 | 44.47 | 212.87 | 70.55 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_3_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 98.78 | 49.81 | 48.97 | 111.05 | 142.81 | 0.00 | 0.00 | 744.00 |
February | 117.98 | 54.53 | 63.45 | 131.25 | 126.61 | 0.00 | 0.00 | 672.00 |
March | 134.94 | 59.64 | 75.30 | 155.47 | 129.38 | 0.00 | 0.00 | 744.00 |
April | 185.97 | 96.68 | 89.28 | 246.64 | 97.55 | 0.00 | 0.00 | 720.00 |
May | 182.67 | 84.25 | 98.43 | 237.55 | 86.50 | 0.00 | 0.00 | 744.00 |
June | 193.46 | 96.60 | 96.87 | 269.74 | 60.93 | 0.00 | 0.00 | 720.00 |
July | 204.85 | 109.50 | 95.35 | 302.99 | 49.96 | 0.00 | 0.00 | 744.00 |
August | 192.23 | 104.09 | 88.14 | 286.42 | 52.61 | 0.00 | 0.00 | 744.00 |
September | 164.76 | 88.13 | 76.62 | 235.27 | 64.87 | 0.00 | 0.00 | 720.00 |
October | 126.55 | 69.34 | 57.21 | 184.91 | 76.07 | 0.00 | 0.00 | 744.00 |
November | 113.87 | 59.60 | 54.27 | 134.94 | 124.24 | 0.00 | 0.00 | 720.00 |
December | 100.16 | 53.56 | 46.61 | 114.70 | 142.30 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 151.48 | 77.24 | 74.24 | 201.26 | 96.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 98.78 | 49.81 | 46.61 | 111.05 | 49.96 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 204.85 | 109.50 | 98.43 | 302.99 | 142.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 20.60 | 0.00 | 20.60 | 13.53 | 75.97 | 0.00 | 0.00 | 744.00 |
February | 25.86 | 0.00 | 25.86 | 15.09 | 68.38 | 0.00 | 0.00 | 672.00 |
March | 31.70 | 0.00 | 31.70 | 21.97 | 70.54 | 0.00 | 0.00 | 744.00 |
April | 36.71 | 0.29 | 36.42 | 31.26 | 52.43 | 0.00 | 0.00 | 720.00 |
May | 44.16 | 2.30 | 41.86 | 37.75 | 44.97 | 0.00 | 0.00 | 744.00 |
June | 46.80 | 4.61 | 42.19 | 47.75 | 31.37 | 0.00 | 0.00 | 720.00 |
July | 44.33 | 3.75 | 40.58 | 51.51 | 26.17 | 0.00 | 0.00 | 744.00 |
August | 36.86 | 0.81 | 36.05 | 44.46 | 27.84 | 0.00 | 0.00 | 744.00 |
September | 31.12 | 0.01 | 31.12 | 35.24 | 35.14 | 0.00 | 0.00 | 720.00 |
October | 24.68 | 0.00 | 24.68 | 31.90 | 40.40 | 0.00 | 0.00 | 744.00 |
November | 22.35 | 0.00 | 22.35 | 15.69 | 66.84 | 0.00 | 0.00 | 720.00 |
December | 19.18 | 0.00 | 19.18 | 12.42 | 75.89 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.06 | 0.99 | 31.07 | 29.97 | 51.24 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 19.18 | 0.00 | 19.18 | 12.42 | 26.17 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 46.80 | 4.61 | 42.19 | 51.51 | 75.97 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_3_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 98.78 | 49.81 | 48.97 | 117.70 | 138.48 | 0.00 | 0.00 | 744.00 |
February | 117.98 | 54.53 | 63.45 | 136.20 | 123.76 | 0.00 | 0.00 | 672.00 |
March | 134.94 | 59.64 | 75.30 | 159.12 | 127.47 | 0.00 | 0.00 | 744.00 |
April | 185.97 | 96.68 | 89.28 | 249.04 | 96.45 | 0.00 | 0.00 | 720.00 |
May | 182.67 | 84.25 | 98.43 | 238.11 | 86.23 | 0.00 | 0.00 | 744.00 |
June | 193.46 | 96.60 | 96.87 | 269.75 | 60.89 | 0.00 | 0.00 | 720.00 |
July | 204.85 | 109.50 | 95.35 | 303.21 | 49.85 | 0.00 | 0.00 | 744.00 |
August | 192.23 | 104.09 | 88.14 | 287.82 | 52.05 | 0.00 | 0.00 | 744.00 |
September | 164.76 | 88.13 | 76.62 | 238.35 | 63.60 | 0.00 | 0.00 | 720.00 |
October | 126.55 | 69.34 | 57.21 | 189.26 | 74.01 | 0.00 | 0.00 | 744.00 |
November | 113.87 | 59.60 | 54.27 | 140.97 | 120.72 | 0.00 | 0.00 | 720.00 |
December | 100.16 | 53.56 | 46.61 | 121.62 | 137.79 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 151.48 | 77.24 | 74.24 | 204.60 | 94.13 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 98.78 | 49.81 | 46.61 | 117.70 | 49.85 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 204.85 | 109.50 | 98.43 | 303.21 | 138.48 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 109.06 | 80.07 | 28.99 | 152.77 | 65.72 | 0.00 | 0.00 | 744.00 |
February | 86.14 | 53.31 | 32.83 | 109.04 | 60.56 | 0.00 | 0.00 | 672.00 |
March | 68.68 | 33.45 | 35.23 | 80.16 | 62.22 | 0.00 | 0.00 | 744.00 |
April | 57.41 | 22.18 | 35.24 | 62.80 | 48.88 | 0.00 | 0.00 | 720.00 |
May | 40.45 | 4.88 | 35.57 | 38.10 | 41.37 | 0.00 | 0.00 | 744.00 |
June | 35.49 | 2.06 | 33.42 | 36.87 | 29.61 | 0.00 | 0.00 | 720.00 |
July | 37.42 | 3.98 | 33.44 | 41.99 | 26.76 | 0.00 | 0.00 | 744.00 |
August | 48.06 | 14.92 | 33.15 | 57.67 | 29.58 | 0.00 | 0.00 | 744.00 |
September | 66.02 | 32.79 | 33.23 | 87.41 | 35.91 | 0.00 | 0.00 | 720.00 |
October | 86.48 | 58.08 | 28.40 | 127.99 | 39.87 | 0.00 | 0.00 | 744.00 |
November | 105.06 | 74.45 | 30.62 | 145.74 | 59.62 | 0.00 | 0.00 | 720.00 |
December | 116.70 | 88.94 | 27.77 | 165.68 | 65.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 71.35 | 39.04 | 32.31 | 92.15 | 47.10 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 35.49 | 2.06 | 27.77 | 36.87 | 26.76 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 116.70 | 88.94 | 35.57 | 165.68 | 65.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 16.49 | 0.00 | 16.49 | 11.01 | 61.67 | 0.00 | 0.00 | 744.00 |
February | 20.69 | 0.00 | 20.69 | 12.40 | 55.55 | 0.00 | 0.00 | 672.00 |
March | 25.36 | 0.00 | 25.36 | 18.13 | 57.18 | 0.00 | 0.00 | 744.00 |
April | 29.37 | 0.23 | 29.14 | 27.18 | 41.34 | 0.00 | 0.00 | 720.00 |
May | 35.33 | 1.84 | 33.49 | 32.57 | 35.63 | 0.00 | 0.00 | 744.00 |
June | 37.45 | 3.69 | 33.76 | 41.37 | 24.46 | 0.00 | 0.00 | 720.00 |
July | 35.47 | 3.00 | 32.47 | 45.06 | 19.92 | 0.00 | 0.00 | 744.00 |
August | 29.50 | 0.65 | 28.84 | 39.12 | 21.01 | 0.00 | 0.00 | 744.00 |
September | 24.90 | 0.00 | 24.90 | 30.79 | 26.94 | 0.00 | 0.00 | 720.00 |
October | 19.75 | 0.00 | 19.75 | 27.43 | 31.64 | 0.00 | 0.00 | 744.00 |
November | 17.88 | 0.00 | 17.88 | 13.16 | 53.56 | 0.00 | 0.00 | 720.00 |
December | 15.35 | 0.00 | 15.35 | 10.21 | 61.46 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 25.65 | 0.79 | 24.86 | 25.79 | 40.79 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 15.35 | 0.00 | 15.35 | 10.21 | 19.92 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 37.45 | 3.69 | 33.76 | 45.06 | 61.67 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_5_FLR_3_WALL_EAST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.66 | 55.39 | 48.28 | 112.40 | 135.07 | 0.00 | 0.00 | 744.00 |
February | 109.39 | 50.05 | 59.33 | 112.42 | 120.95 | 0.00 | 0.00 | 672.00 |
March | 133.51 | 59.64 | 73.88 | 148.75 | 123.31 | 0.00 | 0.00 | 744.00 |
April | 170.18 | 85.39 | 84.79 | 219.08 | 93.27 | 0.00 | 0.00 | 720.00 |
May | 160.28 | 66.79 | 93.49 | 201.75 | 83.36 | 0.00 | 0.00 | 744.00 |
June | 159.47 | 69.23 | 90.24 | 216.33 | 60.06 | 0.00 | 0.00 | 720.00 |
July | 180.59 | 89.71 | 90.87 | 264.52 | 49.81 | 0.00 | 0.00 | 744.00 |
August | 178.49 | 94.86 | 83.63 | 264.45 | 51.23 | 0.00 | 0.00 | 744.00 |
September | 130.32 | 59.94 | 70.38 | 180.33 | 63.31 | 0.00 | 0.00 | 720.00 |
October | 114.85 | 58.95 | 55.90 | 163.44 | 72.28 | 0.00 | 0.00 | 744.00 |
November | 104.45 | 52.88 | 51.57 | 115.74 | 118.81 | 0.00 | 0.00 | 720.00 |
December | 100.41 | 55.96 | 44.45 | 107.67 | 134.55 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 137.32 | 66.70 | 70.62 | 176.01 | 92.02 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 100.41 | 50.05 | 44.45 | 107.67 | 49.81 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.59 | 94.86 | 93.49 | 264.52 | 135.07 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 136.35 | 100.11 | 36.24 | 195.58 | 70.33 | 0.00 | 0.00 | 744.00 |
February | 107.70 | 66.65 | 41.05 | 140.76 | 64.33 | 0.00 | 0.00 | 672.00 |
March | 85.87 | 41.82 | 44.04 | 103.09 | 68.89 | 0.00 | 0.00 | 744.00 |
April | 71.78 | 27.72 | 44.06 | 79.92 | 53.27 | 0.00 | 0.00 | 720.00 |
May | 50.57 | 6.10 | 44.47 | 47.22 | 47.76 | 0.00 | 0.00 | 744.00 |
June | 44.37 | 2.58 | 41.79 | 45.18 | 33.64 | 0.00 | 0.00 | 720.00 |
July | 46.78 | 4.98 | 41.81 | 53.20 | 27.44 | 0.00 | 0.00 | 744.00 |
August | 60.09 | 18.65 | 41.44 | 74.31 | 28.52 | 0.00 | 0.00 | 744.00 |
September | 82.54 | 40.99 | 41.55 | 112.82 | 34.75 | 0.00 | 0.00 | 720.00 |
October | 108.12 | 72.62 | 35.51 | 164.18 | 38.92 | 0.00 | 0.00 | 744.00 |
November | 131.36 | 93.08 | 38.28 | 187.27 | 61.91 | 0.00 | 0.00 | 720.00 |
December | 145.91 | 111.20 | 34.71 | 212.24 | 69.62 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 89.21 | 48.81 | 40.40 | 117.92 | 49.87 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 44.37 | 2.58 | 34.71 | 45.18 | 27.44 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 145.91 | 111.20 | 44.47 | 212.24 | 70.33 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_6_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 20.60 | 0.00 | 20.60 | 12.93 | 75.61 | 0.00 | 0.00 | 744.00 |
February | 25.86 | 0.00 | 25.86 | 14.70 | 67.63 | 0.00 | 0.00 | 672.00 |
March | 31.70 | 0.00 | 31.70 | 21.24 | 70.07 | 0.00 | 0.00 | 744.00 |
April | 36.71 | 0.29 | 36.42 | 30.42 | 51.64 | 0.00 | 0.00 | 720.00 |
May | 44.16 | 2.30 | 41.86 | 37.50 | 44.22 | 0.00 | 0.00 | 744.00 |
June | 46.80 | 4.61 | 42.19 | 47.73 | 30.60 | 0.00 | 0.00 | 720.00 |
July | 44.33 | 3.75 | 40.58 | 50.86 | 25.46 | 0.00 | 0.00 | 744.00 |
August | 36.86 | 0.81 | 36.05 | 43.43 | 27.10 | 0.00 | 0.00 | 744.00 |
September | 31.12 | 0.01 | 31.12 | 35.24 | 33.95 | 0.00 | 0.00 | 720.00 |
October | 24.68 | 0.00 | 24.68 | 31.53 | 39.87 | 0.00 | 0.00 | 744.00 |
November | 22.35 | 0.00 | 22.35 | 15.38 | 65.79 | 0.00 | 0.00 | 720.00 |
December | 19.18 | 0.00 | 19.18 | 11.91 | 75.19 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.06 | 0.99 | 31.07 | 29.50 | 50.51 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 19.18 | 0.00 | 19.18 | 11.91 | 25.46 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 46.80 | 4.61 | 42.19 | 50.86 | 75.61 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_6_FLR_3_WALL_EAST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 103.66 | 55.39 | 48.28 | 118.54 | 129.65 | 0.00 | 0.00 | 744.00 |
February | 109.39 | 50.05 | 59.33 | 117.26 | 117.50 | 0.00 | 0.00 | 672.00 |
March | 133.51 | 59.64 | 73.88 | 152.30 | 121.14 | 0.00 | 0.00 | 744.00 |
April | 170.18 | 85.39 | 84.79 | 221.55 | 92.03 | 0.00 | 0.00 | 720.00 |
May | 160.28 | 66.79 | 93.49 | 202.34 | 83.07 | 0.00 | 0.00 | 744.00 |
June | 159.47 | 69.23 | 90.24 | 216.39 | 60.04 | 0.00 | 0.00 | 720.00 |
July | 180.59 | 89.71 | 90.87 | 264.74 | 49.70 | 0.00 | 0.00 | 744.00 |
August | 178.49 | 94.86 | 83.63 | 265.75 | 50.61 | 0.00 | 0.00 | 744.00 |
September | 130.32 | 59.94 | 70.38 | 183.59 | 61.79 | 0.00 | 0.00 | 720.00 |
October | 114.85 | 58.95 | 55.90 | 167.75 | 70.00 | 0.00 | 0.00 | 744.00 |
November | 104.45 | 52.88 | 51.57 | 121.61 | 114.09 | 0.00 | 0.00 | 720.00 |
December | 100.41 | 55.96 | 44.45 | 114.23 | 128.90 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 137.32 | 66.70 | 70.62 | 179.27 | 89.74 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 100.41 | 50.05 | 44.45 | 114.23 | 49.70 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 180.59 | 94.86 | 93.49 | 265.75 | 129.65 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 26.09 | 0.00 | 26.09 | 17.23 | 97.12 | 0.00 | 0.00 | 744.00 |
February | 32.76 | 0.00 | 32.76 | 19.96 | 86.77 | 0.00 | 0.00 | 672.00 |
March | 40.14 | 0.00 | 40.14 | 29.48 | 89.00 | 0.00 | 0.00 | 744.00 |
April | 46.49 | 0.37 | 46.12 | 44.73 | 64.01 | 0.00 | 0.00 | 720.00 |
May | 55.92 | 2.91 | 53.01 | 54.20 | 54.85 | 0.00 | 0.00 | 744.00 |
June | 59.27 | 5.84 | 53.43 | 68.80 | 37.40 | 0.00 | 0.00 | 720.00 |
July | 56.14 | 4.75 | 51.39 | 74.90 | 30.27 | 0.00 | 0.00 | 744.00 |
August | 46.69 | 1.03 | 45.66 | 64.79 | 31.99 | 0.00 | 0.00 | 744.00 |
September | 39.41 | 0.01 | 39.41 | 50.53 | 41.49 | 0.00 | 0.00 | 720.00 |
October | 31.26 | 0.00 | 31.26 | 44.42 | 49.21 | 0.00 | 0.00 | 744.00 |
November | 28.30 | 0.00 | 28.30 | 20.89 | 84.04 | 0.00 | 0.00 | 720.00 |
December | 24.29 | 0.00 | 24.29 | 15.82 | 96.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 40.60 | 1.25 | 39.35 | 42.28 | 63.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 24.29 | 0.00 | 24.29 | 15.82 | 30.27 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 59.27 | 5.84 | 53.43 | 74.90 | 97.12 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 9.62 | 0.00 | 9.62 | 6.35 | 35.80 | 0.00 | 0.00 | 744.00 |
February | 12.08 | 0.00 | 12.08 | 7.36 | 31.99 | 0.00 | 0.00 | 672.00 |
March | 14.80 | 0.00 | 14.80 | 10.87 | 32.81 | 0.00 | 0.00 | 744.00 |
April | 17.14 | 0.14 | 17.00 | 16.49 | 23.60 | 0.00 | 0.00 | 720.00 |
May | 20.61 | 1.07 | 19.54 | 19.98 | 20.22 | 0.00 | 0.00 | 744.00 |
June | 21.85 | 2.15 | 19.70 | 25.36 | 13.79 | 0.00 | 0.00 | 720.00 |
July | 20.70 | 1.75 | 18.95 | 27.61 | 11.16 | 0.00 | 0.00 | 744.00 |
August | 17.21 | 0.38 | 16.83 | 23.89 | 11.79 | 0.00 | 0.00 | 744.00 |
September | 14.53 | 0.00 | 14.53 | 18.63 | 15.30 | 0.00 | 0.00 | 720.00 |
October | 11.52 | 0.00 | 11.52 | 16.37 | 18.14 | 0.00 | 0.00 | 744.00 |
November | 10.43 | 0.00 | 10.43 | 7.70 | 30.98 | 0.00 | 0.00 | 720.00 |
December | 8.95 | 0.00 | 8.95 | 5.83 | 35.74 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 14.97 | 0.46 | 14.51 | 15.59 | 23.40 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.95 | 0.00 | 8.95 | 5.83 | 11.16 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 21.85 | 2.15 | 19.70 | 27.61 | 35.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 63.62 | 46.71 | 16.91 | 93.55 | 32.24 | 0.00 | 0.00 | 744.00 |
February | 50.25 | 31.10 | 19.15 | 67.65 | 29.79 | 0.00 | 0.00 | 672.00 |
March | 40.06 | 19.51 | 20.55 | 50.01 | 31.80 | 0.00 | 0.00 | 744.00 |
April | 33.49 | 12.94 | 20.56 | 40.11 | 23.97 | 0.00 | 0.00 | 720.00 |
May | 23.60 | 2.85 | 20.75 | 24.53 | 21.59 | 0.00 | 0.00 | 744.00 |
June | 20.70 | 1.20 | 19.50 | 23.98 | 14.94 | 0.00 | 0.00 | 720.00 |
July | 21.83 | 2.32 | 19.51 | 28.53 | 11.80 | 0.00 | 0.00 | 744.00 |
August | 28.04 | 8.70 | 19.34 | 38.42 | 12.14 | 0.00 | 0.00 | 744.00 |
September | 38.51 | 19.13 | 19.39 | 55.54 | 15.25 | 0.00 | 0.00 | 720.00 |
October | 50.45 | 33.88 | 16.57 | 79.40 | 17.25 | 0.00 | 0.00 | 744.00 |
November | 61.29 | 43.43 | 17.86 | 89.78 | 28.28 | 0.00 | 0.00 | 720.00 |
December | 68.08 | 51.88 | 16.20 | 101.39 | 31.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 41.62 | 22.78 | 18.85 | 57.72 | 22.54 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 20.70 | 1.20 | 16.20 | 23.98 | 11.80 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 68.08 | 51.88 | 20.75 | 101.39 | 32.24 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 172.68 | 126.78 | 45.89 | 253.91 | 87.52 | 0.00 | 0.00 | 744.00 |
February | 136.39 | 84.40 | 51.99 | 183.62 | 80.86 | 0.00 | 0.00 | 672.00 |
March | 108.74 | 52.96 | 55.78 | 135.74 | 86.30 | 0.00 | 0.00 | 744.00 |
April | 90.91 | 35.11 | 55.79 | 108.87 | 65.07 | 0.00 | 0.00 | 720.00 |
May | 64.05 | 7.73 | 56.32 | 66.57 | 58.60 | 0.00 | 0.00 | 744.00 |
June | 56.19 | 3.27 | 52.92 | 65.09 | 40.55 | 0.00 | 0.00 | 720.00 |
July | 59.25 | 6.30 | 52.95 | 77.43 | 32.02 | 0.00 | 0.00 | 744.00 |
August | 76.10 | 23.62 | 52.48 | 104.28 | 32.94 | 0.00 | 0.00 | 744.00 |
September | 104.53 | 51.91 | 52.62 | 150.74 | 41.39 | 0.00 | 0.00 | 720.00 |
October | 136.93 | 91.96 | 44.97 | 215.50 | 46.83 | 0.00 | 0.00 | 744.00 |
November | 166.35 | 117.88 | 48.48 | 243.68 | 76.75 | 0.00 | 0.00 | 720.00 |
December | 184.78 | 140.82 | 43.96 | 275.18 | 86.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.98 | 61.82 | 51.16 | 156.66 | 61.19 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 56.19 | 3.27 | 43.96 | 65.09 | 32.02 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 184.78 | 140.82 | 56.32 | 275.18 | 87.52 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 136.46 | 100.19 | 36.27 | 195.21 | 70.24 | 0.00 | 0.00 | 744.00 |
February | 107.78 | 66.70 | 41.08 | 139.80 | 64.67 | 0.00 | 0.00 | 672.00 |
March | 85.94 | 41.86 | 44.08 | 102.68 | 69.41 | 0.00 | 0.00 | 744.00 |
April | 71.84 | 27.75 | 44.09 | 79.34 | 54.40 | 0.00 | 0.00 | 720.00 |
May | 50.62 | 6.11 | 44.51 | 46.19 | 49.11 | 0.00 | 0.00 | 744.00 |
June | 44.40 | 2.58 | 41.82 | 43.87 | 35.20 | 0.00 | 0.00 | 720.00 |
July | 46.82 | 4.98 | 41.84 | 52.35 | 28.91 | 0.00 | 0.00 | 744.00 |
August | 60.14 | 18.67 | 41.48 | 73.67 | 29.85 | 0.00 | 0.00 | 744.00 |
September | 82.60 | 41.02 | 41.58 | 111.20 | 36.16 | 0.00 | 0.00 | 720.00 |
October | 108.21 | 72.67 | 35.54 | 162.98 | 39.58 | 0.00 | 0.00 | 744.00 |
November | 131.46 | 93.16 | 38.31 | 186.10 | 62.34 | 0.00 | 0.00 | 720.00 |
December | 146.03 | 111.29 | 34.74 | 211.49 | 69.63 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 89.28 | 48.85 | 40.43 | 117.02 | 50.72 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 44.40 | 2.58 | 34.74 | 43.87 | 28.91 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 146.03 | 111.29 | 44.51 | 211.49 | 70.24 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_1_FLR_6_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 98.86 | 49.86 | 49.01 | 109.55 | 141.72 | 0.00 | 0.00 | 744.00 |
February | 118.07 | 54.57 | 63.50 | 129.24 | 125.76 | 0.00 | 0.00 | 672.00 |
March | 135.05 | 59.68 | 75.37 | 152.76 | 128.99 | 0.00 | 0.00 | 744.00 |
April | 186.12 | 96.76 | 89.36 | 242.11 | 97.70 | 0.00 | 0.00 | 720.00 |
May | 182.82 | 84.32 | 98.51 | 232.65 | 86.79 | 0.00 | 0.00 | 744.00 |
June | 193.62 | 96.68 | 96.95 | 264.17 | 61.40 | 0.00 | 0.00 | 720.00 |
July | 205.02 | 109.59 | 95.43 | 297.47 | 50.54 | 0.00 | 0.00 | 744.00 |
August | 192.39 | 104.18 | 88.22 | 281.31 | 53.29 | 0.00 | 0.00 | 744.00 |
September | 164.89 | 88.21 | 76.69 | 231.09 | 65.29 | 0.00 | 0.00 | 720.00 |
October | 126.65 | 69.39 | 57.26 | 182.24 | 76.11 | 0.00 | 0.00 | 744.00 |
November | 113.97 | 59.65 | 54.31 | 132.99 | 123.51 | 0.00 | 0.00 | 720.00 |
December | 100.25 | 53.60 | 46.65 | 113.39 | 141.05 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 151.61 | 77.30 | 74.30 | 197.75 | 95.87 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 98.86 | 49.86 | 46.65 | 109.55 | 50.54 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 205.02 | 109.59 | 98.51 | 297.47 | 141.72 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 20.62 | 0.00 | 20.62 | 13.51 | 75.13 | 0.00 | 0.00 | 744.00 |
February | 25.89 | 0.00 | 25.89 | 14.91 | 67.79 | 0.00 | 0.00 | 672.00 |
March | 31.72 | 0.00 | 31.72 | 21.39 | 70.26 | 0.00 | 0.00 | 744.00 |
April | 36.74 | 0.29 | 36.45 | 29.86 | 52.53 | 0.00 | 0.00 | 720.00 |
May | 44.19 | 2.30 | 41.89 | 36.04 | 45.11 | 0.00 | 0.00 | 744.00 |
June | 46.84 | 4.62 | 42.22 | 45.64 | 31.61 | 0.00 | 0.00 | 720.00 |
July | 44.37 | 3.75 | 40.61 | 49.34 | 26.47 | 0.00 | 0.00 | 744.00 |
August | 36.89 | 0.82 | 36.08 | 42.56 | 28.23 | 0.00 | 0.00 | 744.00 |
September | 31.15 | 0.01 | 31.14 | 33.82 | 35.39 | 0.00 | 0.00 | 720.00 |
October | 24.70 | 0.00 | 24.70 | 31.13 | 40.35 | 0.00 | 0.00 | 744.00 |
November | 22.37 | 0.00 | 22.37 | 15.53 | 66.30 | 0.00 | 0.00 | 720.00 |
December | 19.20 | 0.00 | 19.20 | 12.51 | 74.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.08 | 0.99 | 31.10 | 28.94 | 51.09 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 19.20 | 0.00 | 19.20 | 12.51 | 26.47 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 46.84 | 4.62 | 42.22 | 49.34 | 75.13 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_2_FLR_6_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 98.86 | 49.86 | 49.01 | 116.82 | 136.96 | 0.00 | 0.00 | 744.00 |
February | 118.07 | 54.57 | 63.50 | 134.63 | 122.63 | 0.00 | 0.00 | 672.00 |
March | 135.05 | 59.68 | 75.37 | 156.64 | 126.94 | 0.00 | 0.00 | 744.00 |
April | 186.12 | 96.76 | 89.36 | 244.55 | 96.52 | 0.00 | 0.00 | 720.00 |
May | 182.82 | 84.32 | 98.51 | 233.19 | 86.51 | 0.00 | 0.00 | 744.00 |
June | 193.62 | 96.68 | 96.95 | 264.15 | 61.37 | 0.00 | 0.00 | 720.00 |
July | 205.02 | 109.59 | 95.43 | 297.63 | 50.44 | 0.00 | 0.00 | 744.00 |
August | 192.39 | 104.18 | 88.22 | 282.53 | 52.74 | 0.00 | 0.00 | 744.00 |
September | 164.89 | 88.21 | 76.69 | 234.09 | 63.97 | 0.00 | 0.00 | 720.00 |
October | 126.65 | 69.39 | 57.26 | 186.63 | 73.92 | 0.00 | 0.00 | 744.00 |
November | 113.97 | 59.65 | 54.31 | 139.50 | 119.63 | 0.00 | 0.00 | 720.00 |
December | 100.25 | 53.60 | 46.65 | 120.96 | 136.08 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 151.61 | 77.30 | 74.30 | 201.27 | 93.84 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 98.86 | 49.86 | 46.65 | 116.82 | 50.44 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 205.02 | 109.59 | 98.51 | 297.63 | 136.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 200.14 | 146.94 | 53.19 | 281.03 | 107.44 | 0.00 | 0.00 | 744.00 |
February | 158.08 | 97.82 | 60.25 | 201.28 | 98.07 | 0.00 | 0.00 | 672.00 |
March | 126.03 | 61.38 | 64.65 | 148.17 | 103.73 | 0.00 | 0.00 | 744.00 |
April | 105.36 | 40.69 | 64.67 | 116.75 | 78.78 | 0.00 | 0.00 | 720.00 |
May | 74.23 | 8.96 | 65.27 | 70.34 | 69.93 | 0.00 | 0.00 | 744.00 |
June | 65.12 | 3.79 | 61.33 | 68.08 | 48.98 | 0.00 | 0.00 | 720.00 |
July | 68.67 | 7.30 | 61.36 | 80.84 | 39.61 | 0.00 | 0.00 | 744.00 |
August | 88.20 | 27.38 | 60.83 | 110.57 | 41.65 | 0.00 | 0.00 | 744.00 |
September | 121.15 | 60.17 | 60.98 | 163.35 | 52.10 | 0.00 | 0.00 | 720.00 |
October | 158.70 | 106.58 | 52.12 | 237.35 | 58.98 | 0.00 | 0.00 | 744.00 |
November | 192.80 | 136.62 | 56.18 | 268.70 | 94.78 | 0.00 | 0.00 | 720.00 |
December | 214.17 | 163.21 | 50.95 | 304.81 | 106.55 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 130.94 | 71.65 | 59.29 | 170.87 | 74.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 65.12 | 3.79 | 50.95 | 68.08 | 39.61 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 214.17 | 163.21 | 65.27 | 304.81 | 107.44 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: BANQUET_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 144.35 | 0.00 | 144.35 | 68.14 | 643.41 | 0.00 | 0.00 | 744.00 |
February | 181.19 | 0.00 | 181.19 | 73.88 | 603.54 | 0.00 | 0.00 | 672.00 |
March | 222.06 | 0.00 | 222.05 | 117.88 | 609.15 | 0.00 | 0.00 | 744.00 |
April | 257.16 | 2.05 | 255.11 | 185.85 | 458.15 | 0.00 | 0.00 | 720.00 |
May | 309.33 | 16.08 | 293.25 | 223.91 | 398.63 | 0.00 | 0.00 | 744.00 |
June | 327.87 | 32.32 | 295.55 | 294.33 | 289.51 | 0.00 | 0.00 | 720.00 |
July | 310.57 | 26.28 | 284.29 | 326.81 | 246.36 | 0.00 | 0.00 | 744.00 |
August | 258.25 | 5.71 | 252.55 | 283.55 | 267.71 | 0.00 | 0.00 | 744.00 |
September | 218.02 | 0.04 | 217.98 | 221.52 | 325.37 | 0.00 | 0.00 | 720.00 |
October | 172.93 | 0.00 | 172.93 | 199.30 | 373.46 | 0.00 | 0.00 | 744.00 |
November | 156.57 | 0.00 | 156.57 | 81.62 | 577.13 | 0.00 | 0.00 | 720.00 |
December | 134.37 | 0.00 | 134.37 | 61.88 | 645.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 224.57 | 6.91 | 217.66 | 178.89 | 452.35 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 134.37 | 0.00 | 134.37 | 61.88 | 246.36 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 327.87 | 32.32 | 295.55 | 326.81 | 645.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: DINING_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 144.35 | 0.00 | 144.35 | 60.03 | 669.44 | 0.00 | 0.00 | 744.00 |
February | 181.19 | 0.00 | 181.19 | 64.63 | 629.63 | 0.00 | 0.00 | 672.00 |
March | 222.06 | 0.00 | 222.05 | 106.27 | 633.45 | 0.00 | 0.00 | 744.00 |
April | 257.16 | 2.05 | 255.11 | 171.25 | 476.86 | 0.00 | 0.00 | 720.00 |
May | 309.33 | 16.08 | 293.25 | 206.32 | 414.76 | 0.00 | 0.00 | 744.00 |
June | 327.87 | 32.32 | 295.55 | 275.43 | 302.46 | 0.00 | 0.00 | 720.00 |
July | 310.57 | 26.28 | 284.29 | 308.75 | 258.10 | 0.00 | 0.00 | 744.00 |
August | 258.25 | 5.71 | 252.55 | 267.91 | 281.49 | 0.00 | 0.00 | 744.00 |
September | 218.02 | 0.04 | 217.98 | 207.63 | 342.67 | 0.00 | 0.00 | 720.00 |
October | 172.93 | 0.00 | 172.93 | 187.37 | 392.17 | 0.00 | 0.00 | 744.00 |
November | 156.57 | 0.00 | 156.57 | 72.37 | 601.03 | 0.00 | 0.00 | 720.00 |
December | 134.37 | 0.00 | 134.37 | 54.31 | 671.57 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 224.57 | 6.91 | 217.66 | 165.83 | 471.98 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 134.37 | 0.00 | 134.37 | 54.31 | 258.10 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 327.87 | 32.32 | 295.55 | 308.75 | 671.57 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 20.62 | 0.00 | 20.62 | 13.70 | 83.59 | 0.00 | 0.00 | 744.00 |
February | 25.89 | 0.00 | 25.89 | 14.50 | 79.93 | 0.00 | 0.00 | 672.00 |
March | 31.72 | 0.00 | 31.72 | 22.06 | 81.26 | 0.00 | 0.00 | 744.00 |
April | 36.74 | 0.29 | 36.45 | 34.20 | 61.34 | 0.00 | 0.00 | 720.00 |
May | 44.19 | 2.30 | 41.89 | 41.51 | 54.43 | 0.00 | 0.00 | 744.00 |
June | 46.84 | 4.62 | 42.22 | 53.47 | 39.29 | 0.00 | 0.00 | 720.00 |
July | 44.37 | 3.75 | 40.61 | 59.21 | 32.94 | 0.00 | 0.00 | 744.00 |
August | 36.89 | 0.82 | 36.08 | 51.42 | 35.00 | 0.00 | 0.00 | 744.00 |
September | 31.15 | 0.01 | 31.14 | 40.20 | 41.08 | 0.00 | 0.00 | 720.00 |
October | 24.70 | 0.00 | 24.70 | 35.74 | 47.39 | 0.00 | 0.00 | 744.00 |
November | 22.37 | 0.00 | 22.37 | 16.20 | 74.85 | 0.00 | 0.00 | 720.00 |
December | 19.20 | 0.00 | 19.20 | 12.59 | 83.66 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 32.08 | 0.99 | 31.10 | 33.02 | 59.45 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 19.20 | 0.00 | 19.20 | 12.59 | 32.94 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 46.84 | 4.62 | 42.22 | 59.21 | 83.66 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_EAST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 207.48 | 110.86 | 96.62 | 242.99 | 292.93 | 0.00 | 0.00 | 744.00 |
February | 218.94 | 100.18 | 118.76 | 234.06 | 283.70 | 0.00 | 0.00 | 672.00 |
March | 267.23 | 119.37 | 147.86 | 309.10 | 287.07 | 0.00 | 0.00 | 744.00 |
April | 340.62 | 170.92 | 169.70 | 460.05 | 222.99 | 0.00 | 0.00 | 720.00 |
May | 320.81 | 133.69 | 187.12 | 420.58 | 205.24 | 0.00 | 0.00 | 744.00 |
June | 319.18 | 138.56 | 180.62 | 456.50 | 154.08 | 0.00 | 0.00 | 720.00 |
July | 361.45 | 179.56 | 181.89 | 562.89 | 129.29 | 0.00 | 0.00 | 744.00 |
August | 357.26 | 189.87 | 167.38 | 563.20 | 132.79 | 0.00 | 0.00 | 744.00 |
September | 260.84 | 119.98 | 140.86 | 388.33 | 153.09 | 0.00 | 0.00 | 720.00 |
October | 229.87 | 117.99 | 111.89 | 353.55 | 170.92 | 0.00 | 0.00 | 744.00 |
November | 209.06 | 105.84 | 103.22 | 247.55 | 264.93 | 0.00 | 0.00 | 720.00 |
December | 200.98 | 112.01 | 88.96 | 232.38 | 292.56 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 274.85 | 133.50 | 141.35 | 373.57 | 215.43 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 200.98 | 100.18 | 88.96 | 232.38 | 129.29 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 361.45 | 189.87 | 187.12 | 563.20 | 292.93 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 136.46 | 100.19 | 36.27 | 202.20 | 77.00 | 0.00 | 0.00 | 744.00 |
February | 107.78 | 66.70 | 41.08 | 144.22 | 76.04 | 0.00 | 0.00 | 672.00 |
March | 85.94 | 41.86 | 44.08 | 106.30 | 79.97 | 0.00 | 0.00 | 744.00 |
April | 71.84 | 27.75 | 44.09 | 85.11 | 62.92 | 0.00 | 0.00 | 720.00 |
May | 50.62 | 6.11 | 44.51 | 50.98 | 58.15 | 0.00 | 0.00 | 744.00 |
June | 44.40 | 2.58 | 41.82 | 51.00 | 42.70 | 0.00 | 0.00 | 720.00 |
July | 46.82 | 4.98 | 41.84 | 61.79 | 35.15 | 0.00 | 0.00 | 744.00 |
August | 60.14 | 18.67 | 41.48 | 83.12 | 36.30 | 0.00 | 0.00 | 744.00 |
September | 82.60 | 41.02 | 41.58 | 119.99 | 41.64 | 0.00 | 0.00 | 720.00 |
October | 108.21 | 72.67 | 35.54 | 171.65 | 46.24 | 0.00 | 0.00 | 744.00 |
November | 131.46 | 93.16 | 38.31 | 193.16 | 69.90 | 0.00 | 0.00 | 720.00 |
December | 146.03 | 111.29 | 34.74 | 218.69 | 76.59 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 89.28 | 48.85 | 40.43 | 123.98 | 58.45 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 44.40 | 2.58 | 34.74 | 50.98 | 35.15 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 146.03 | 111.29 | 44.51 | 218.69 | 79.97 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 26.12 | 0.00 | 26.12 | 14.48 | 101.11 | 0.00 | 0.00 | 744.00 |
February | 32.78 | 0.00 | 32.78 | 16.82 | 90.96 | 0.00 | 0.00 | 672.00 |
March | 40.18 | 0.00 | 40.18 | 25.88 | 92.96 | 0.00 | 0.00 | 744.00 |
April | 46.53 | 0.37 | 46.16 | 39.57 | 68.21 | 0.00 | 0.00 | 720.00 |
May | 55.97 | 2.91 | 53.06 | 48.62 | 58.52 | 0.00 | 0.00 | 744.00 |
June | 59.32 | 5.85 | 53.47 | 61.68 | 41.50 | 0.00 | 0.00 | 720.00 |
July | 56.19 | 4.75 | 51.44 | 66.24 | 35.37 | 0.00 | 0.00 | 744.00 |
August | 46.72 | 1.03 | 45.69 | 56.59 | 38.09 | 0.00 | 0.00 | 744.00 |
September | 39.45 | 0.01 | 39.44 | 44.66 | 46.64 | 0.00 | 0.00 | 720.00 |
October | 31.29 | 0.00 | 31.29 | 39.03 | 55.02 | 0.00 | 0.00 | 744.00 |
November | 28.33 | 0.00 | 28.33 | 17.55 | 88.48 | 0.00 | 0.00 | 720.00 |
December | 24.31 | 0.00 | 24.31 | 13.06 | 100.95 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 40.63 | 1.25 | 39.38 | 37.14 | 68.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 24.31 | 0.00 | 24.31 | 13.06 | 35.37 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 59.32 | 5.85 | 53.47 | 66.24 | 101.11 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.37 | 0.00 | 23.37 | 12.96 | 90.46 | 0.00 | 0.00 | 744.00 |
February | 29.33 | 0.00 | 29.33 | 15.05 | 81.38 | 0.00 | 0.00 | 672.00 |
March | 35.95 | 0.00 | 35.95 | 23.16 | 83.17 | 0.00 | 0.00 | 744.00 |
April | 41.63 | 0.33 | 41.30 | 35.40 | 61.03 | 0.00 | 0.00 | 720.00 |
May | 50.07 | 2.60 | 47.47 | 43.50 | 52.36 | 0.00 | 0.00 | 744.00 |
June | 53.07 | 5.23 | 47.84 | 55.19 | 37.13 | 0.00 | 0.00 | 720.00 |
July | 50.27 | 4.25 | 46.02 | 59.26 | 31.64 | 0.00 | 0.00 | 744.00 |
August | 41.80 | 0.92 | 40.88 | 50.63 | 34.08 | 0.00 | 0.00 | 744.00 |
September | 35.29 | 0.01 | 35.29 | 39.96 | 41.73 | 0.00 | 0.00 | 720.00 |
October | 27.99 | 0.00 | 27.99 | 34.92 | 49.23 | 0.00 | 0.00 | 744.00 |
November | 25.35 | 0.00 | 25.35 | 15.70 | 79.16 | 0.00 | 0.00 | 720.00 |
December | 21.75 | 0.00 | 21.75 | 11.68 | 90.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 36.35 | 1.12 | 35.23 | 33.23 | 60.87 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 21.75 | 0.00 | 21.75 | 11.68 | 31.64 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 53.07 | 5.23 | 47.84 | 59.26 | 90.46 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 509.46 | 374.05 | 135.40 | 734.22 | 268.42 | 0.00 | 0.00 | 744.00 |
February | 402.39 | 249.01 | 153.38 | 526.15 | 250.09 | 0.00 | 0.00 | 672.00 |
March | 320.83 | 156.26 | 164.57 | 386.53 | 266.77 | 0.00 | 0.00 | 744.00 |
April | 268.20 | 103.59 | 164.61 | 304.90 | 205.53 | 0.00 | 0.00 | 720.00 |
May | 188.96 | 22.81 | 166.16 | 180.57 | 185.83 | 0.00 | 0.00 | 744.00 |
June | 165.77 | 9.64 | 156.12 | 172.97 | 134.24 | 0.00 | 0.00 | 720.00 |
July | 174.79 | 18.59 | 156.20 | 204.87 | 112.14 | 0.00 | 0.00 | 744.00 |
August | 224.53 | 69.69 | 154.84 | 283.73 | 116.75 | 0.00 | 0.00 | 744.00 |
September | 308.39 | 153.16 | 155.23 | 425.20 | 137.89 | 0.00 | 0.00 | 720.00 |
October | 403.98 | 271.32 | 132.66 | 614.96 | 154.99 | 0.00 | 0.00 | 744.00 |
November | 490.79 | 347.78 | 143.02 | 701.70 | 238.12 | 0.00 | 0.00 | 720.00 |
December | 545.17 | 415.47 | 129.70 | 795.66 | 265.77 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 333.32 | 182.39 | 150.93 | 444.09 | 194.43 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 165.77 | 9.64 | 129.70 | 172.97 | 112.14 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 545.17 | 415.47 | 166.16 | 795.66 | 268.42 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: RETAIL_1_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.185087E+10 | 0.135894E+10 | 0.491925E+09 | 0.262981E+10 | 0.959297E+09 |
February | 0.132042E+10 | 0.817125E+09 | 0.503297E+09 | 0.172725E+10 | 0.790192E+09 |
March | 0.116557E+10 | 0.567687E+09 | 0.597878E+09 | 0.142019E+10 | 0.910353E+09 |
April | 0.942948E+09 | 0.364206E+09 | 0.578742E+09 | 0.108668E+10 | 0.681792E+09 |
May | 0.686508E+09 | 82855603.57 | 0.603653E+09 | 0.684022E+09 | 0.623784E+09 |
June | 0.582802E+09 | 33895534.00 | 0.548907E+09 | 0.635575E+09 | 0.433074E+09 |
July | 0.635032E+09 | 67536201.96 | 0.567496E+09 | 0.768941E+09 | 0.370200E+09 |
August | 0.815705E+09 | 0.253170E+09 | 0.562535E+09 | 0.104476E+10 | 0.391032E+09 |
September | 0.108424E+10 | 0.538468E+09 | 0.545767E+09 | 0.148924E+10 | 0.470673E+09 |
October | 0.146767E+10 | 0.985700E+09 | 0.481969E+09 | 0.220679E+10 | 0.562515E+09 |
November | 0.172555E+10 | 0.122273E+10 | 0.502820E+09 | 0.243929E+10 | 0.831345E+09 |
December | 0.198061E+10 | 0.150940E+10 | 0.471217E+09 | 0.284786E+10 | 0.962409E+09 |
Annual Sum or Average | 0.142579E+11 | 0.780170E+10 | 0.645621E+10 | 0.189804E+11 | 0.798667E+10 |
Minimum of Months | 0.582802E+09 | 33895534.00 | 0.471217E+09 | 0.635575E+09 | 0.370200E+09 |
Maximum of Months | 0.198061E+10 | 0.150940E+10 | 0.603653E+09 | 0.284786E+10 | 0.962409E+09 |
Report: WindowEnergyReportMonthly
For: CAFE_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.521191E+10 | 0.382669E+10 | 0.138523E+10 | 0.731778E+10 | 0.291485E+10 |
February | 0.371822E+10 | 0.230097E+10 | 0.141725E+10 | 0.478174E+10 | 0.244284E+10 |
March | 0.328216E+10 | 0.159857E+10 | 0.168359E+10 | 0.392180E+10 | 0.277960E+10 |
April | 0.265528E+10 | 0.102558E+10 | 0.162970E+10 | 0.298583E+10 | 0.213546E+10 |
May | 0.193316E+10 | 0.233316E+09 | 0.169985E+10 | 0.184938E+10 | 0.195436E+10 |
June | 0.164113E+10 | 95447588.87 | 0.154569E+10 | 0.171043E+10 | 0.139301E+10 |
July | 0.178821E+10 | 0.190177E+09 | 0.159803E+10 | 0.208388E+10 | 0.120211E+10 |
August | 0.229697E+10 | 0.712911E+09 | 0.158406E+10 | 0.287074E+10 | 0.127520E+10 |
September | 0.305313E+10 | 0.151629E+10 | 0.153684E+10 | 0.412929E+10 | 0.151560E+10 |
October | 0.413286E+10 | 0.277567E+10 | 0.135719E+10 | 0.614017E+10 | 0.178534E+10 |
November | 0.485902E+10 | 0.344311E+10 | 0.141591E+10 | 0.677178E+10 | 0.257399E+10 |
December | 0.557728E+10 | 0.425036E+10 | 0.132692E+10 | 0.792367E+10 | 0.293253E+10 |
Annual Sum or Average | 0.401493E+11 | 0.219691E+11 | 0.181803E+11 | 0.524865E+11 | 0.249049E+11 |
Minimum of Months | 0.164113E+10 | 95447588.87 | 0.132692E+10 | 0.171043E+10 | 0.120211E+10 |
Maximum of Months | 0.557728E+10 | 0.425036E+10 | 0.169985E+10 | 0.792367E+10 | 0.293253E+10 |
Report: WindowEnergyReportMonthly
For: LOBBY_FLR_1_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.677057E+10 | 0.497108E+10 | 0.179949E+10 | 0.976596E+10 | 0.383565E+10 |
February | 0.483018E+10 | 0.298909E+10 | 0.184109E+10 | 0.636695E+10 | 0.326810E+10 |
March | 0.426371E+10 | 0.207663E+10 | 0.218707E+10 | 0.520671E+10 | 0.375795E+10 |
April | 0.344936E+10 | 0.133229E+10 | 0.211707E+10 | 0.396077E+10 | 0.288657E+10 |
May | 0.251129E+10 | 0.303091E+09 | 0.220820E+10 | 0.243222E+10 | 0.267928E+10 |
June | 0.213192E+10 | 0.123992E+09 | 0.200793E+10 | 0.225797E+10 | 0.190647E+10 |
July | 0.232298E+10 | 0.247051E+09 | 0.207593E+10 | 0.276877E+10 | 0.163322E+10 |
August | 0.298390E+10 | 0.926112E+09 | 0.205779E+10 | 0.383010E+10 | 0.170093E+10 |
September | 0.396620E+10 | 0.196975E+10 | 0.199645E+10 | 0.551442E+10 | 0.200305E+10 |
October | 0.536882E+10 | 0.360575E+10 | 0.176307E+10 | 0.820899E+10 | 0.232062E+10 |
November | 0.631215E+10 | 0.447280E+10 | 0.183935E+10 | 0.902935E+10 | 0.339235E+10 |
December | 0.724520E+10 | 0.552146E+10 | 0.172374E+10 | 0.105775E+11 | 0.385338E+10 |
Annual Sum or Average | 0.521563E+11 | 0.285391E+11 | 0.236172E+11 | 0.699197E+11 | 0.332376E+11 |
Minimum of Months | 0.213192E+10 | 0.123992E+09 | 0.172374E+10 | 0.225797E+10 | 0.163322E+10 |
Maximum of Months | 0.724520E+10 | 0.552146E+10 | 0.220820E+10 | 0.105775E+11 | 0.385338E+10 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.365202E+09 | 0.268138E+09 | 97063741.13 | 0.526023E+09 | 0.188959E+09 |
February | 0.260538E+09 | 0.161230E+09 | 99307626.30 | 0.341681E+09 | 0.157043E+09 |
March | 0.229983E+09 | 0.112013E+09 | 0.117970E+09 | 0.278424E+09 | 0.185852E+09 |
April | 0.186057E+09 | 71862951.28 | 0.114194E+09 | 0.209903E+09 | 0.140352E+09 |
May | 0.135458E+09 | 16348586.95 | 0.119109E+09 | 0.127999E+09 | 0.130567E+09 |
June | 0.114995E+09 | 6688070.10 | 0.108307E+09 | 0.118317E+09 | 90136256.93 |
July | 0.125301E+09 | 13325851.52 | 0.111975E+09 | 0.145175E+09 | 76195596.69 |
August | 0.160950E+09 | 49954094.11 | 0.110996E+09 | 0.202108E+09 | 78671548.11 |
September | 0.213935E+09 | 0.106247E+09 | 0.107688E+09 | 0.292888E+09 | 92901850.48 |
October | 0.289592E+09 | 0.194493E+09 | 95099285.37 | 0.440988E+09 | 0.105714E+09 |
November | 0.340475E+09 | 0.241261E+09 | 99213597.08 | 0.486434E+09 | 0.162048E+09 |
December | 0.390803E+09 | 0.297825E+09 | 92977895.08 | 0.570138E+09 | 0.187540E+09 |
Annual Sum or Average | 0.281329E+10 | 0.153939E+10 | 0.127390E+10 | 0.374008E+10 | 0.159598E+10 |
Minimum of Months | 0.114995E+09 | 6688070.10 | 92977895.08 | 0.118317E+09 | 76195596.69 |
Maximum of Months | 0.390803E+09 | 0.297825E+09 | 0.119109E+09 | 0.570138E+09 | 0.188959E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_3_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.264577E+09 | 0.133423E+09 | 0.131154E+09 | 0.297441E+09 | 0.382491E+09 |
February | 0.285409E+09 | 0.131915E+09 | 0.153493E+09 | 0.317513E+09 | 0.306300E+09 |
March | 0.361422E+09 | 0.159729E+09 | 0.201693E+09 | 0.416414E+09 | 0.346521E+09 |
April | 0.482027E+09 | 0.250603E+09 | 0.231424E+09 | 0.639293E+09 | 0.252860E+09 |
May | 0.489272E+09 | 0.225646E+09 | 0.263626E+09 | 0.636264E+09 | 0.231691E+09 |
June | 0.501458E+09 | 0.250379E+09 | 0.251079E+09 | 0.699169E+09 | 0.157925E+09 |
July | 0.548681E+09 | 0.293289E+09 | 0.255392E+09 | 0.811539E+09 | 0.133802E+09 |
August | 0.514880E+09 | 0.278798E+09 | 0.236082E+09 | 0.767145E+09 | 0.140918E+09 |
September | 0.427052E+09 | 0.228445E+09 | 0.198607E+09 | 0.609810E+09 | 0.168155E+09 |
October | 0.338943E+09 | 0.185711E+09 | 0.153233E+09 | 0.495263E+09 | 0.203738E+09 |
November | 0.295162E+09 | 0.154495E+09 | 0.140668E+09 | 0.349771E+09 | 0.322026E+09 |
December | 0.268281E+09 | 0.143444E+09 | 0.124837E+09 | 0.307214E+09 | 0.381123E+09 |
Annual Sum or Average | 0.477717E+10 | 0.243588E+10 | 0.234129E+10 | 0.634684E+10 | 0.302755E+10 |
Minimum of Months | 0.264577E+09 | 0.131915E+09 | 0.124837E+09 | 0.297441E+09 | 0.133802E+09 |
Maximum of Months | 0.548681E+09 | 0.293289E+09 | 0.263626E+09 | 0.811539E+09 | 0.382491E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 55187410.10 | 0.00 | 55187410.10 | 36233830.56 | 0.203480E+09 |
February | 62570938.96 | 0.00 | 62570938.96 | 36505911.53 | 0.165427E+09 |
March | 84898795.36 | 753.87 | 84898041.50 | 58852671.60 | 0.188930E+09 |
April | 95148727.15 | 759942.51 | 94388784.64 | 81013102.21 | 0.135902E+09 |
May | 0.118266E+09 | 6148054.32 | 0.112118E+09 | 0.101113E+09 | 0.120436E+09 |
June | 0.121311E+09 | 11957604.86 | 0.109354E+09 | 0.123780E+09 | 81321462.42 |
July | 0.118739E+09 | 10047152.59 | 0.108692E+09 | 0.137975E+09 | 70101346.82 |
August | 98737814.75 | 2181324.43 | 96556490.32 | 0.119080E+09 | 74554142.26 |
September | 80667879.41 | 15675.90 | 80652203.51 | 91354175.61 | 91094924.90 |
October | 66114501.28 | 0.00 | 66114501.28 | 85441841.02 | 0.108219E+09 |
November | 57930922.12 | 0.00 | 57930922.12 | 40667987.47 | 0.173260E+09 |
December | 51374769.97 | 0.00 | 51374769.97 | 33257610.41 | 0.203255E+09 |
Annual Sum or Average | 0.101095E+10 | 31110508.49 | 0.979838E+09 | 0.945276E+09 | 0.161598E+10 |
Minimum of Months | 51374769.97 | 0.00 | 51374769.97 | 33257610.41 | 70101346.82 |
Maximum of Months | 0.121311E+09 | 11957604.86 | 0.112118E+09 | 0.137975E+09 | 0.203480E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_3_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.264577E+09 | 0.133423E+09 | 0.131154E+09 | 0.315243E+09 | 0.370915E+09 |
February | 0.285409E+09 | 0.131915E+09 | 0.153493E+09 | 0.329489E+09 | 0.299393E+09 |
March | 0.361422E+09 | 0.159729E+09 | 0.201693E+09 | 0.426184E+09 | 0.341410E+09 |
April | 0.482027E+09 | 0.250603E+09 | 0.231424E+09 | 0.645521E+09 | 0.249996E+09 |
May | 0.489272E+09 | 0.225646E+09 | 0.263626E+09 | 0.637754E+09 | 0.230969E+09 |
June | 0.501458E+09 | 0.250379E+09 | 0.251079E+09 | 0.699185E+09 | 0.157832E+09 |
July | 0.548681E+09 | 0.293289E+09 | 0.255392E+09 | 0.812119E+09 | 0.133525E+09 |
August | 0.514880E+09 | 0.278798E+09 | 0.236082E+09 | 0.770902E+09 | 0.139407E+09 |
September | 0.427052E+09 | 0.228445E+09 | 0.198607E+09 | 0.617803E+09 | 0.164856E+09 |
October | 0.338943E+09 | 0.185711E+09 | 0.153233E+09 | 0.506913E+09 | 0.198225E+09 |
November | 0.295162E+09 | 0.154495E+09 | 0.140668E+09 | 0.365402E+09 | 0.312918E+09 |
December | 0.268281E+09 | 0.143444E+09 | 0.124837E+09 | 0.325747E+09 | 0.369068E+09 |
Annual Sum or Average | 0.477717E+10 | 0.243588E+10 | 0.234129E+10 | 0.645226E+10 | 0.296852E+10 |
Minimum of Months | 0.264577E+09 | 0.131915E+09 | 0.124837E+09 | 0.315243E+09 | 0.133525E+09 |
Maximum of Months | 0.548681E+09 | 0.293289E+09 | 0.263626E+09 | 0.812119E+09 | 0.370915E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_3_MULT19_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.292103E+09 | 0.214468E+09 | 77635553.28 | 0.409185E+09 | 0.176020E+09 |
February | 0.208389E+09 | 0.128959E+09 | 79430304.49 | 0.263780E+09 | 0.146517E+09 |
March | 0.183949E+09 | 89592320.13 | 94357165.29 | 0.214696E+09 | 0.166648E+09 |
April | 0.148816E+09 | 57478930.01 | 91337075.93 | 0.162788E+09 | 0.126708E+09 |
May | 0.108345E+09 | 13076269.05 | 95268456.07 | 0.102045E+09 | 0.110798E+09 |
June | 91977834.87 | 5349392.23 | 86628442.64 | 95568521.62 | 76753128.71 |
July | 0.100221E+09 | 10658561.51 | 89562197.17 | 0.112476E+09 | 71676734.20 |
August | 0.128735E+09 | 39955329.25 | 88779244.96 | 0.154455E+09 | 79239824.81 |
September | 0.171114E+09 | 84981032.64 | 86132926.04 | 0.226556E+09 | 93079212.01 |
October | 0.231627E+09 | 0.155563E+09 | 76064301.16 | 0.342818E+09 | 0.106789E+09 |
November | 0.272326E+09 | 0.192970E+09 | 79355096.08 | 0.377749E+09 | 0.154537E+09 |
December | 0.312580E+09 | 0.238213E+09 | 74367526.37 | 0.443770E+09 | 0.176657E+09 |
Annual Sum or Average | 0.225018E+10 | 0.123126E+10 | 0.101892E+10 | 0.290588E+10 | 0.148542E+10 |
Minimum of Months | 91977834.87 | 5349392.23 | 74367526.37 | 95568521.62 | 71676734.20 |
Maximum of Months | 0.312580E+09 | 0.238213E+09 | 95268456.07 | 0.443770E+09 | 0.176657E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_4_MULT19_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 44155780.40 | 0.00 | 44155780.40 | 29492845.37 | 0.165185E+09 |
February | 50063386.48 | 0.00 | 50063386.48 | 29988247.66 | 0.134383E+09 |
March | 67928039.34 | 603.17 | 67927436.17 | 48551821.58 | 0.153163E+09 |
April | 76129071.72 | 608034.59 | 75521037.12 | 70460195.97 | 0.107163E+09 |
May | 94625527.60 | 4919095.43 | 89706432.17 | 87235539.49 | 95426638.52 |
June | 97061928.37 | 9567351.92 | 87494576.45 | 0.107244E+09 | 63404836.94 |
July | 95003827.50 | 8038787.52 | 86965039.98 | 0.120688E+09 | 53355523.01 |
August | 79000722.41 | 1745290.87 | 77255431.54 | 0.104783E+09 | 56260769.27 |
September | 64542857.91 | 12542.38 | 64530315.53 | 79819879.62 | 69817711.06 |
October | 52898612.11 | 0.00 | 52898612.11 | 73473002.78 | 84740504.50 |
November | 46350880.95 | 0.00 | 46350880.95 | 34101186.15 | 0.138829E+09 |
December | 41105263.99 | 0.00 | 41105263.99 | 27353049.46 | 0.164624E+09 |
Annual Sum or Average | 0.808866E+09 | 24891705.89 | 0.783974E+09 | 0.813191E+09 | 0.128635E+10 |
Minimum of Months | 41105263.99 | 0.00 | 41105263.99 | 27353049.46 | 53355523.01 |
Maximum of Months | 97061928.37 | 9567351.92 | 89706432.17 | 0.120688E+09 | 0.165185E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_5_FLR_3_WALL_EAST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277649E+09 | 0.148349E+09 | 0.129300E+09 | 0.301049E+09 | 0.361763E+09 |
February | 0.264631E+09 | 0.121091E+09 | 0.143540E+09 | 0.271974E+09 | 0.292609E+09 |
March | 0.357605E+09 | 0.159739E+09 | 0.197867E+09 | 0.398418E+09 | 0.330286E+09 |
April | 0.441116E+09 | 0.221343E+09 | 0.219773E+09 | 0.567868E+09 | 0.241749E+09 |
May | 0.429306E+09 | 0.178897E+09 | 0.250408E+09 | 0.540357E+09 | 0.223273E+09 |
June | 0.413350E+09 | 0.179438E+09 | 0.233913E+09 | 0.560724E+09 | 0.155685E+09 |
July | 0.483690E+09 | 0.240292E+09 | 0.243398E+09 | 0.708498E+09 | 0.133406E+09 |
August | 0.478079E+09 | 0.254085E+09 | 0.223994E+09 | 0.708290E+09 | 0.137225E+09 |
September | 0.337794E+09 | 0.155377E+09 | 0.182417E+09 | 0.467415E+09 | 0.164108E+09 |
October | 0.307616E+09 | 0.157887E+09 | 0.149729E+09 | 0.437767E+09 | 0.193596E+09 |
November | 0.270739E+09 | 0.137061E+09 | 0.133678E+09 | 0.299992E+09 | 0.307965E+09 |
December | 0.268947E+09 | 0.149895E+09 | 0.119052E+09 | 0.288377E+09 | 0.360383E+09 |
Annual Sum or Average | 0.433052E+10 | 0.210345E+10 | 0.222707E+10 | 0.555073E+10 | 0.290205E+10 |
Minimum of Months | 0.264631E+09 | 0.121091E+09 | 0.119052E+09 | 0.271974E+09 | 0.133406E+09 |
Maximum of Months | 0.483690E+09 | 0.254085E+09 | 0.250408E+09 | 0.708498E+09 | 0.361763E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_5_FLR_3_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.365202E+09 | 0.268138E+09 | 97063741.13 | 0.523836E+09 | 0.188362E+09 |
February | 0.260538E+09 | 0.161230E+09 | 99307626.30 | 0.340536E+09 | 0.155633E+09 |
March | 0.229983E+09 | 0.112013E+09 | 0.117970E+09 | 0.276115E+09 | 0.184523E+09 |
April | 0.186057E+09 | 71862951.28 | 0.114194E+09 | 0.207161E+09 | 0.138088E+09 |
May | 0.135458E+09 | 16348586.95 | 0.119109E+09 | 0.126468E+09 | 0.127908E+09 |
June | 0.114995E+09 | 6688070.10 | 0.108307E+09 | 0.117099E+09 | 87197396.20 |
July | 0.125301E+09 | 13325851.52 | 0.111975E+09 | 0.142490E+09 | 73488455.45 |
August | 0.160950E+09 | 49954094.11 | 0.110996E+09 | 0.199038E+09 | 76381498.61 |
September | 0.213935E+09 | 0.106247E+09 | 0.107688E+09 | 0.292436E+09 | 90068403.97 |
October | 0.289592E+09 | 0.194493E+09 | 95099285.37 | 0.439735E+09 | 0.104255E+09 |
November | 0.340475E+09 | 0.241261E+09 | 99213597.08 | 0.485413E+09 | 0.160474E+09 |
December | 0.390803E+09 | 0.297825E+09 | 92977895.08 | 0.568452E+09 | 0.186458E+09 |
Annual Sum or Average | 0.281329E+10 | 0.153939E+10 | 0.127390E+10 | 0.371878E+10 | 0.157284E+10 |
Minimum of Months | 0.114995E+09 | 6688070.10 | 92977895.08 | 0.117099E+09 | 73488455.45 |
Maximum of Months | 0.390803E+09 | 0.297825E+09 | 0.119109E+09 | 0.568452E+09 | 0.188362E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_6_FLR_3_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 55187410.10 | 0.00 | 55187410.10 | 34625670.57 | 0.202519E+09 |
February | 62570938.96 | 0.00 | 62570938.96 | 35563292.87 | 0.163600E+09 |
March | 84898795.36 | 753.87 | 84898041.50 | 56884482.46 | 0.187670E+09 |
April | 95148727.15 | 759942.51 | 94388784.64 | 78848589.23 | 0.133861E+09 |
May | 0.118266E+09 | 6148054.32 | 0.112118E+09 | 0.100434E+09 | 0.118444E+09 |
June | 0.121311E+09 | 11957604.86 | 0.109354E+09 | 0.123703E+09 | 79319647.40 |
July | 0.118739E+09 | 10047152.59 | 0.108692E+09 | 0.136229E+09 | 68197885.20 |
August | 98737814.75 | 2181324.43 | 96556490.32 | 0.116331E+09 | 72586714.26 |
September | 80667879.41 | 15675.90 | 80652203.51 | 91345383.69 | 88000092.44 |
October | 66114501.28 | 0.00 | 66114501.28 | 84460540.20 | 0.106800E+09 |
November | 57930922.12 | 0.00 | 57930922.12 | 39874795.26 | 0.170519E+09 |
December | 51374769.97 | 0.00 | 51374769.97 | 31895744.82 | 0.201383E+09 |
Annual Sum or Average | 0.101095E+10 | 31110508.49 | 0.979838E+09 | 0.930195E+09 | 0.159290E+10 |
Minimum of Months | 51374769.97 | 0.00 | 51374769.97 | 31895744.82 | 68197885.20 |
Maximum of Months | 0.121311E+09 | 11957604.86 | 0.112118E+09 | 0.136229E+09 | 0.202519E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_6_FLR_3_WALL_EAST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.277649E+09 | 0.148349E+09 | 0.129300E+09 | 0.317490E+09 | 0.347259E+09 |
February | 0.264631E+09 | 0.121091E+09 | 0.143540E+09 | 0.283667E+09 | 0.284245E+09 |
March | 0.357605E+09 | 0.159739E+09 | 0.197867E+09 | 0.407929E+09 | 0.324455E+09 |
April | 0.441116E+09 | 0.221343E+09 | 0.219773E+09 | 0.574247E+09 | 0.238554E+09 |
May | 0.429306E+09 | 0.178897E+09 | 0.250408E+09 | 0.541936E+09 | 0.222490E+09 |
June | 0.413350E+09 | 0.179438E+09 | 0.233913E+09 | 0.560880E+09 | 0.155627E+09 |
July | 0.483690E+09 | 0.240292E+09 | 0.243398E+09 | 0.709090E+09 | 0.133119E+09 |
August | 0.478079E+09 | 0.254085E+09 | 0.223994E+09 | 0.711773E+09 | 0.135556E+09 |
September | 0.337794E+09 | 0.155377E+09 | 0.182417E+09 | 0.475878E+09 | 0.160147E+09 |
October | 0.307616E+09 | 0.157887E+09 | 0.149729E+09 | 0.449302E+09 | 0.187479E+09 |
November | 0.270739E+09 | 0.137061E+09 | 0.133678E+09 | 0.315203E+09 | 0.295730E+09 |
December | 0.268947E+09 | 0.149895E+09 | 0.119052E+09 | 0.305956E+09 | 0.345253E+09 |
Annual Sum or Average | 0.433052E+10 | 0.210345E+10 | 0.222707E+10 | 0.565335E+10 | 0.282991E+10 |
Minimum of Months | 0.264631E+09 | 0.121091E+09 | 0.119052E+09 | 0.283667E+09 | 0.133119E+09 |
Maximum of Months | 0.483690E+09 | 0.254085E+09 | 0.250408E+09 | 0.711773E+09 | 0.347259E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_1_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 69891372.75 | 0.00 | 69891372.75 | 46159656.44 | 0.260118E+09 |
February | 79242146.19 | 0.00 | 79242146.19 | 48283257.15 | 0.209917E+09 |
March | 0.107519E+09 | 954.73 | 0.107518E+09 | 78950032.10 | 0.238377E+09 |
April | 0.120500E+09 | 962419.24 | 0.119537E+09 | 0.115942E+09 | 0.165917E+09 |
May | 0.149777E+09 | 7786122.88 | 0.141991E+09 | 0.145181E+09 | 0.146898E+09 |
June | 0.153633E+09 | 15143552.07 | 0.138490E+09 | 0.178320E+09 | 96940944.07 |
July | 0.150376E+09 | 12724084.82 | 0.137651E+09 | 0.200601E+09 | 81065648.08 |
August | 0.125045E+09 | 2762509.76 | 0.122283E+09 | 0.173545E+09 | 85679472.73 |
September | 0.102161E+09 | 19852.54 | 0.102141E+09 | 0.130974E+09 | 0.107547E+09 |
October | 83729844.28 | 0.00 | 83729844.28 | 0.118974E+09 | 0.131816E+09 |
November | 73365857.63 | 0.00 | 73365857.63 | 54134183.13 | 0.217822E+09 |
December | 65062904.60 | 0.00 | 65062904.60 | 42359021.51 | 0.259697E+09 |
Annual Sum or Average | 0.128030E+10 | 39399496.03 | 0.124090E+10 | 0.133342E+10 | 0.200180E+10 |
Minimum of Months | 65062904.60 | 0.00 | 65062904.60 | 42359021.51 | 81065648.08 |
Maximum of Months | 0.153633E+09 | 15143552.07 | 0.141991E+09 | 0.200601E+09 | 0.260118E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_2_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 25764853.97 | 0.00 | 25764853.97 | 17016360.69 | 95890445.43 |
February | 29211936.25 | 0.00 | 29211936.25 | 17799207.84 | 77383977.98 |
March | 39635943.43 | 351.95 | 39635591.48 | 29104250.90 | 87875663.64 |
April | 44421237.67 | 354787.58 | 44066450.09 | 42740986.90 | 61163989.42 |
May | 55213901.29 | 2870287.29 | 52343614.00 | 53519741.54 | 54152626.30 |
June | 56635538.72 | 5582540.34 | 51052998.38 | 65736131.06 | 35736445.99 |
July | 55434638.91 | 4690624.53 | 50744014.38 | 73949913.94 | 29884154.55 |
August | 46096843.00 | 1018375.49 | 45078467.51 | 63975918.53 | 31585001.36 |
September | 37660693.44 | 7318.47 | 37653374.97 | 48282348.09 | 39646134.65 |
October | 30866287.58 | 0.00 | 30866287.58 | 43858619.65 | 48593012.03 |
November | 27045692.96 | 0.00 | 27045692.96 | 19956101.42 | 80298335.97 |
December | 23984880.68 | 0.00 | 23984880.68 | 15615289.28 | 95734891.28 |
Annual Sum or Average | 0.471972E+09 | 14524285.64 | 0.457448E+09 | 0.491555E+09 | 0.737945E+09 |
Minimum of Months | 23984880.68 | 0.00 | 23984880.68 | 15615289.28 | 29884154.55 |
Maximum of Months | 56635538.72 | 5582540.34 | 52343614.00 | 73949913.94 | 95890445.43 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_1_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.170402E+09 | 0.125112E+09 | 45289550.47 | 0.250561E+09 | 86361162.40 |
February | 0.121566E+09 | 75229412.69 | 46336538.25 | 0.163665E+09 | 72070481.24 |
March | 0.107309E+09 | 52264661.39 | 55044286.02 | 0.133951E+09 | 85163103.34 |
April | 86813447.28 | 33530963.48 | 53282483.80 | 0.103964E+09 | 62139570.34 |
May | 63204082.27 | 7628184.79 | 55575897.48 | 65696150.18 | 57831754.16 |
June | 53656277.55 | 3120626.56 | 50535650.99 | 62154751.19 | 38720135.13 |
July | 58464877.45 | 6217788.62 | 52247088.84 | 76408385.12 | 31599548.01 |
August | 75098724.10 | 23308379.01 | 51790345.09 | 0.102907E+09 | 32508770.62 |
September | 99821202.28 | 49574616.32 | 50246585.96 | 0.143949E+09 | 39528925.43 |
October | 0.135122E+09 | 90749476.67 | 44372943.33 | 0.212658E+09 | 46212849.70 |
November | 0.158864E+09 | 0.112571E+09 | 46292664.60 | 0.232707E+09 | 73290506.54 |
December | 0.182347E+09 | 0.138964E+09 | 43383111.17 | 0.271552E+09 | 85534471.92 |
Annual Sum or Average | 0.131267E+10 | 0.718272E+09 | 0.594397E+09 | 0.182017E+10 | 0.710961E+09 |
Minimum of Months | 53656277.55 | 3120626.56 | 43383111.17 | 62154751.19 | 31599548.01 |
Maximum of Months | 0.182347E+09 | 0.138964E+09 | 55575897.48 | 0.271552E+09 | 86361162.40 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_3_WALL_2_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.462505E+09 | 0.339580E+09 | 0.122925E+09 | 0.680075E+09 | 0.234402E+09 |
February | 0.329955E+09 | 0.204188E+09 | 0.125767E+09 | 0.444221E+09 | 0.195614E+09 |
March | 0.291258E+09 | 0.141857E+09 | 0.149401E+09 | 0.363571E+09 | 0.231150E+09 |
April | 0.235629E+09 | 91009893.49 | 0.144620E+09 | 0.282180E+09 | 0.168659E+09 |
May | 0.171549E+09 | 20704453.84 | 0.150844E+09 | 0.178313E+09 | 0.156967E+09 |
June | 0.145634E+09 | 8470018.79 | 0.137164E+09 | 0.168701E+09 | 0.105094E+09 |
July | 0.158686E+09 | 16876350.13 | 0.141809E+09 | 0.207388E+09 | 85767636.83 |
August | 0.203833E+09 | 63263708.26 | 0.140570E+09 | 0.279310E+09 | 88235451.96 |
September | 0.270935E+09 | 0.134556E+09 | 0.136380E+09 | 0.390707E+09 | 0.107290E+09 |
October | 0.366750E+09 | 0.246313E+09 | 0.120437E+09 | 0.577196E+09 | 0.125431E+09 |
November | 0.431190E+09 | 0.305542E+09 | 0.125648E+09 | 0.631614E+09 | 0.198925E+09 |
December | 0.494927E+09 | 0.377177E+09 | 0.117751E+09 | 0.737048E+09 | 0.232158E+09 |
Annual Sum or Average | 0.356285E+10 | 0.194954E+10 | 0.161332E+10 | 0.494032E+10 | 0.192969E+10 |
Minimum of Months | 0.145634E+09 | 8470018.79 | 0.117751E+09 | 0.168701E+09 | 85767636.83 |
Maximum of Months | 0.494927E+09 | 0.377177E+09 | 0.150844E+09 | 0.737048E+09 | 0.234402E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.365502E+09 | 0.268358E+09 | 97143366.84 | 0.522838E+09 | 0.188132E+09 |
February | 0.260752E+09 | 0.161363E+09 | 99389092.77 | 0.338198E+09 | 0.156446E+09 |
March | 0.230171E+09 | 0.112105E+09 | 0.118067E+09 | 0.275022E+09 | 0.185908E+09 |
April | 0.186210E+09 | 71921903.66 | 0.114288E+09 | 0.205641E+09 | 0.141003E+09 |
May | 0.135569E+09 | 16361998.43 | 0.119207E+09 | 0.123721E+09 | 0.131531E+09 |
June | 0.115089E+09 | 6693556.62 | 0.108396E+09 | 0.113699E+09 | 91236591.66 |
July | 0.125404E+09 | 13336783.30 | 0.112067E+09 | 0.140218E+09 | 77436445.83 |
August | 0.161082E+09 | 49995073.68 | 0.111087E+09 | 0.197315E+09 | 79955713.46 |
September | 0.214110E+09 | 0.106335E+09 | 0.107776E+09 | 0.288240E+09 | 93735212.09 |
October | 0.289829E+09 | 0.194652E+09 | 95177299.55 | 0.436527E+09 | 0.106010E+09 |
November | 0.340754E+09 | 0.241459E+09 | 99294986.42 | 0.482374E+09 | 0.161595E+09 |
December | 0.391124E+09 | 0.298070E+09 | 93054168.99 | 0.566453E+09 | 0.186498E+09 |
Annual Sum or Average | 0.281560E+10 | 0.154065E+10 | 0.127495E+10 | 0.369024E+10 | 0.159949E+10 |
Minimum of Months | 0.115089E+09 | 6693556.62 | 93054168.99 | 0.113699E+09 | 77436445.83 |
Maximum of Months | 0.391124E+09 | 0.298070E+09 | 0.119207E+09 | 0.566453E+09 | 0.188132E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_1_FLR_6_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.264794E+09 | 0.133533E+09 | 0.131261E+09 | 0.293424E+09 | 0.379584E+09 |
February | 0.285643E+09 | 0.132024E+09 | 0.153619E+09 | 0.312650E+09 | 0.304250E+09 |
March | 0.361719E+09 | 0.159860E+09 | 0.201858E+09 | 0.409157E+09 | 0.345493E+09 |
April | 0.482422E+09 | 0.250808E+09 | 0.231614E+09 | 0.627545E+09 | 0.253234E+09 |
May | 0.489673E+09 | 0.225831E+09 | 0.263842E+09 | 0.623132E+09 | 0.232461E+09 |
June | 0.501869E+09 | 0.250584E+09 | 0.251285E+09 | 0.684727E+09 | 0.159158E+09 |
July | 0.549131E+09 | 0.293530E+09 | 0.255601E+09 | 0.796749E+09 | 0.135354E+09 |
August | 0.515303E+09 | 0.279027E+09 | 0.236276E+09 | 0.753448E+09 | 0.142743E+09 |
September | 0.427403E+09 | 0.228632E+09 | 0.198770E+09 | 0.598994E+09 | 0.169227E+09 |
October | 0.339222E+09 | 0.185863E+09 | 0.153359E+09 | 0.488113E+09 | 0.203855E+09 |
November | 0.295405E+09 | 0.154621E+09 | 0.140783E+09 | 0.344717E+09 | 0.320142E+09 |
December | 0.268502E+09 | 0.143562E+09 | 0.124940E+09 | 0.303701E+09 | 0.377797E+09 |
Annual Sum or Average | 0.478108E+10 | 0.243788E+10 | 0.234321E+10 | 0.623636E+10 | 0.302330E+10 |
Minimum of Months | 0.264794E+09 | 0.132024E+09 | 0.124940E+09 | 0.293424E+09 | 0.135354E+09 |
Maximum of Months | 0.549131E+09 | 0.293530E+09 | 0.263842E+09 | 0.796749E+09 | 0.379584E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 55232682.79 | 0.00 | 55232682.79 | 36173094.09 | 0.201229E+09 |
February | 62622268.69 | 0.00 | 62622268.69 | 36064630.10 | 0.164007E+09 |
March | 84968441.63 | 754.49 | 84967687.14 | 57282060.69 | 0.188189E+09 |
April | 95226781.88 | 760565.92 | 94466215.96 | 77403554.54 | 0.136147E+09 |
May | 0.118363E+09 | 6153097.85 | 0.112210E+09 | 96537923.04 | 0.120828E+09 |
June | 0.121411E+09 | 11967414.21 | 0.109443E+09 | 0.118312E+09 | 81944471.67 |
July | 0.118836E+09 | 10055394.72 | 0.108781E+09 | 0.132155E+09 | 70890199.19 |
August | 98818813.78 | 2183113.87 | 96635699.91 | 0.113995E+09 | 75613062.38 |
September | 80734054.86 | 15688.76 | 80718366.10 | 87671062.04 | 91731388.06 |
October | 66168737.95 | 0.00 | 66168737.95 | 83382790.83 | 0.108070E+09 |
November | 57978445.44 | 0.00 | 57978445.44 | 40248476.73 | 0.171837E+09 |
December | 51416914.99 | 0.00 | 51416914.99 | 33501699.11 | 0.200705E+09 |
Annual Sum or Average | 0.101178E+10 | 31136029.82 | 0.980642E+09 | 0.912727E+09 | 0.161119E+10 |
Minimum of Months | 51416914.99 | 0.00 | 51416914.99 | 33501699.11 | 70890199.19 |
Maximum of Months | 0.121411E+09 | 11967414.21 | 0.112210E+09 | 0.132155E+09 | 0.201229E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_2_FLR_6_WALL_WEST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.264794E+09 | 0.133533E+09 | 0.131261E+09 | 0.312880E+09 | 0.366846E+09 |
February | 0.285643E+09 | 0.132024E+09 | 0.153619E+09 | 0.325690E+09 | 0.296671E+09 |
March | 0.361719E+09 | 0.159860E+09 | 0.201858E+09 | 0.419544E+09 | 0.339993E+09 |
April | 0.482422E+09 | 0.250808E+09 | 0.231614E+09 | 0.633875E+09 | 0.250191E+09 |
May | 0.489673E+09 | 0.225831E+09 | 0.263842E+09 | 0.624570E+09 | 0.231720E+09 |
June | 0.501869E+09 | 0.250584E+09 | 0.251285E+09 | 0.684686E+09 | 0.159068E+09 |
July | 0.549131E+09 | 0.293530E+09 | 0.255601E+09 | 0.797176E+09 | 0.135090E+09 |
August | 0.515303E+09 | 0.279027E+09 | 0.236276E+09 | 0.756723E+09 | 0.141250E+09 |
September | 0.427403E+09 | 0.228632E+09 | 0.198770E+09 | 0.606749E+09 | 0.165801E+09 |
October | 0.339222E+09 | 0.185863E+09 | 0.153359E+09 | 0.499882E+09 | 0.197996E+09 |
November | 0.295405E+09 | 0.154621E+09 | 0.140783E+09 | 0.361584E+09 | 0.310090E+09 |
December | 0.268502E+09 | 0.143562E+09 | 0.124940E+09 | 0.323986E+09 | 0.364465E+09 |
Annual Sum or Average | 0.478108E+10 | 0.243788E+10 | 0.234321E+10 | 0.634735E+10 | 0.295918E+10 |
Minimum of Months | 0.264794E+09 | 0.132024E+09 | 0.124940E+09 | 0.312880E+09 | 0.135090E+09 |
Maximum of Months | 0.549131E+09 | 0.293530E+09 | 0.263842E+09 | 0.797176E+09 | 0.366846E+09 |
Report: WindowEnergyReportMonthly
For: ROOM_3_MULT9_FLR_6_WALL_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.536043E+09 | 0.393573E+09 | 0.142470E+09 | 0.752698E+09 | 0.287769E+09 |
February | 0.382417E+09 | 0.236654E+09 | 0.145764E+09 | 0.486942E+09 | 0.237250E+09 |
March | 0.337568E+09 | 0.164412E+09 | 0.173156E+09 | 0.396867E+09 | 0.277826E+09 |
April | 0.273094E+09 | 0.105480E+09 | 0.167614E+09 | 0.302614E+09 | 0.204189E+09 |
May | 0.198825E+09 | 23996440.96 | 0.174828E+09 | 0.188408E+09 | 0.187311E+09 |
June | 0.168790E+09 | 9816743.17 | 0.158973E+09 | 0.176453E+09 | 0.126952E+09 |
July | 0.183916E+09 | 19559672.65 | 0.164357E+09 | 0.216515E+09 | 0.106081E+09 |
August | 0.236243E+09 | 73322573.59 | 0.162920E+09 | 0.296149E+09 | 0.111563E+09 |
September | 0.314014E+09 | 0.155950E+09 | 0.158064E+09 | 0.423409E+09 | 0.135032E+09 |
October | 0.425063E+09 | 0.285476E+09 | 0.139587E+09 | 0.635716E+09 | 0.157979E+09 |
November | 0.499748E+09 | 0.354123E+09 | 0.145626E+09 | 0.696481E+09 | 0.245673E+09 |
December | 0.573620E+09 | 0.437148E+09 | 0.136473E+09 | 0.816404E+09 | 0.285386E+09 |
Annual Sum or Average | 0.412934E+10 | 0.225951E+10 | 0.186983E+10 | 0.538866E+10 | 0.236301E+10 |
Minimum of Months | 0.168790E+09 | 9816743.17 | 0.136473E+09 | 0.176453E+09 | 0.106081E+09 |
Maximum of Months | 0.573620E+09 | 0.437148E+09 | 0.174828E+09 | 0.816404E+09 | 0.287769E+09 |
Report: WindowEnergyReportMonthly
For: BANQUET_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.386614E+09 | 0.00 | 0.386614E+09 | 0.182509E+09 | 0.172330E+10 |
February | 0.438339E+09 | 0.00 | 0.438339E+09 | 0.178734E+09 | 0.146009E+10 |
March | 0.594757E+09 | 5281.20 | 0.594751E+09 | 0.315722E+09 | 0.163155E+10 |
April | 0.666562E+09 | 5323759.83 | 0.661238E+09 | 0.481716E+09 | 0.118752E+10 |
May | 0.828511E+09 | 43070053.68 | 0.785441E+09 | 0.599710E+09 | 0.106768E+10 |
June | 0.849844E+09 | 83768726.79 | 0.766075E+09 | 0.762896E+09 | 0.750409E+09 |
July | 0.831824E+09 | 70385097.24 | 0.761439E+09 | 0.875325E+09 | 0.659852E+09 |
August | 0.691705E+09 | 15281218.34 | 0.676424E+09 | 0.759456E+09 | 0.717030E+09 |
September | 0.565117E+09 | 109817.17 | 0.565007E+09 | 0.574192E+09 | 0.843366E+09 |
October | 0.463164E+09 | 0.00 | 0.463164E+09 | 0.533810E+09 | 0.100028E+10 |
November | 0.405834E+09 | 0.00 | 0.405834E+09 | 0.211561E+09 | 0.149592E+10 |
December | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.165736E+09 | 0.172824E+10 |
Annual Sum or Average | 0.708218E+10 | 0.217944E+09 | 0.686423E+10 | 0.564137E+10 | 0.142652E+11 |
Minimum of Months | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.165736E+09 | 0.659852E+09 |
Maximum of Months | 0.849844E+09 | 83768726.79 | 0.785441E+09 | 0.875325E+09 | 0.172824E+10 |
Report: WindowEnergyReportMonthly
For: DINING_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.386614E+09 | 0.00 | 0.386614E+09 | 0.160791E+09 | 0.179303E+10 |
February | 0.438339E+09 | 0.00 | 0.438339E+09 | 0.156348E+09 | 0.152320E+10 |
March | 0.594757E+09 | 5281.20 | 0.594751E+09 | 0.284629E+09 | 0.169664E+10 |
April | 0.666562E+09 | 5323759.83 | 0.661238E+09 | 0.443878E+09 | 0.123603E+10 |
May | 0.828511E+09 | 43070053.68 | 0.785441E+09 | 0.552601E+09 | 0.111089E+10 |
June | 0.849844E+09 | 83768726.79 | 0.766075E+09 | 0.713921E+09 | 0.783964E+09 |
July | 0.831824E+09 | 70385097.24 | 0.761439E+09 | 0.826959E+09 | 0.691295E+09 |
August | 0.691705E+09 | 15281218.34 | 0.676424E+09 | 0.717568E+09 | 0.753941E+09 |
September | 0.565117E+09 | 109817.17 | 0.565007E+09 | 0.538167E+09 | 0.888212E+09 |
October | 0.463164E+09 | 0.00 | 0.463164E+09 | 0.501852E+09 | 0.105040E+10 |
November | 0.405834E+09 | 0.00 | 0.405834E+09 | 0.187576E+09 | 0.155786E+10 |
December | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.145456E+09 | 0.179874E+10 |
Annual Sum or Average | 0.708218E+10 | 0.217944E+09 | 0.686423E+10 | 0.522974E+10 | 0.148842E+11 |
Minimum of Months | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.145456E+09 | 0.691295E+09 |
Maximum of Months | 0.849844E+09 | 83768726.79 | 0.785441E+09 | 0.826959E+09 | 0.179874E+10 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 55232682.79 | 0.00 | 55232682.79 | 36686961.04 | 0.223899E+09 |
February | 62622268.69 | 0.00 | 62622268.69 | 35086936.87 | 0.193358E+09 |
March | 84968441.63 | 754.49 | 84967687.14 | 59092563.63 | 0.217644E+09 |
April | 95226781.88 | 760565.92 | 94466215.96 | 88647826.52 | 0.158982E+09 |
May | 0.118363E+09 | 6153097.85 | 0.112210E+09 | 0.111170E+09 | 0.145775E+09 |
June | 0.121411E+09 | 11967414.21 | 0.109443E+09 | 0.138603E+09 | 0.101827E+09 |
July | 0.118836E+09 | 10055394.72 | 0.108781E+09 | 0.158580E+09 | 88219566.23 |
August | 98818813.78 | 2183113.87 | 96635699.91 | 0.137733E+09 | 93743816.83 |
September | 80734054.86 | 15688.76 | 80718366.10 | 0.104201E+09 | 0.106475E+09 |
October | 66168737.95 | 0.00 | 66168737.95 | 95715324.08 | 0.126918E+09 |
November | 57978445.44 | 0.00 | 57978445.44 | 41980182.22 | 0.194001E+09 |
December | 51416914.99 | 0.00 | 51416914.99 | 33721568.76 | 0.224069E+09 |
Annual Sum or Average | 0.101178E+10 | 31136029.82 | 0.980642E+09 | 0.104122E+10 | 0.187491E+10 |
Minimum of Months | 51416914.99 | 0.00 | 51416914.99 | 33721568.76 | 88219566.23 |
Maximum of Months | 0.121411E+09 | 11967414.21 | 0.112210E+09 | 0.158580E+09 | 0.224069E+09 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_EAST_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.555714E+09 | 0.296920E+09 | 0.258794E+09 | 0.650835E+09 | 0.784589E+09 |
February | 0.529658E+09 | 0.242363E+09 | 0.287295E+09 | 0.566247E+09 | 0.686330E+09 |
March | 0.715747E+09 | 0.319716E+09 | 0.396030E+09 | 0.827905E+09 | 0.768879E+09 |
April | 0.882893E+09 | 0.443018E+09 | 0.439875E+09 | 0.119244E+10 | 0.578003E+09 |
May | 0.859255E+09 | 0.358063E+09 | 0.501192E+09 | 0.112648E+10 | 0.549724E+09 |
June | 0.827320E+09 | 0.359144E+09 | 0.468176E+09 | 0.118326E+10 | 0.399374E+09 |
July | 0.968105E+09 | 0.480944E+09 | 0.487161E+09 | 0.150765E+10 | 0.346287E+09 |
August | 0.956875E+09 | 0.508552E+09 | 0.448323E+09 | 0.150847E+10 | 0.355675E+09 |
September | 0.676094E+09 | 0.310988E+09 | 0.365107E+09 | 0.100654E+10 | 0.396812E+09 |
October | 0.615693E+09 | 0.316011E+09 | 0.299682E+09 | 0.946959E+09 | 0.457795E+09 |
November | 0.541883E+09 | 0.274327E+09 | 0.267556E+09 | 0.641642E+09 | 0.686696E+09 |
December | 0.538297E+09 | 0.300015E+09 | 0.238282E+09 | 0.622413E+09 | 0.783581E+09 |
Annual Sum or Average | 0.866753E+10 | 0.421006E+10 | 0.445747E+10 | 0.117808E+11 | 0.679374E+10 |
Minimum of Months | 0.529658E+09 | 0.242363E+09 | 0.238282E+09 | 0.566247E+09 | 0.346287E+09 |
Maximum of Months | 0.968105E+09 | 0.508552E+09 | 0.501192E+09 | 0.150847E+10 | 0.784589E+09 |
Report: WindowEnergyReportMonthly
For: KITCHEN_FLR_6_WALL_1_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.365502E+09 | 0.268358E+09 | 97143366.84 | 0.541584E+09 | 0.206233E+09 |
February | 0.260752E+09 | 0.161363E+09 | 99389092.77 | 0.348888E+09 | 0.183963E+09 |
March | 0.230171E+09 | 0.112105E+09 | 0.118067E+09 | 0.284713E+09 | 0.214183E+09 |
April | 0.186210E+09 | 71921903.66 | 0.114288E+09 | 0.220613E+09 | 0.163094E+09 |
May | 0.135569E+09 | 16361998.43 | 0.119207E+09 | 0.136533E+09 | 0.155751E+09 |
June | 0.115089E+09 | 6693556.62 | 0.108396E+09 | 0.132188E+09 | 0.110680E+09 |
July | 0.125404E+09 | 13336783.30 | 0.112067E+09 | 0.165508E+09 | 94150969.07 |
August | 0.161082E+09 | 49995073.68 | 0.111087E+09 | 0.222636E+09 | 97232868.29 |
September | 0.214110E+09 | 0.106335E+09 | 0.107776E+09 | 0.311020E+09 | 0.107929E+09 |
October | 0.289829E+09 | 0.194652E+09 | 95177299.55 | 0.459752E+09 | 0.123842E+09 |
November | 0.340754E+09 | 0.241459E+09 | 99294986.42 | 0.500663E+09 | 0.181183E+09 |
December | 0.391124E+09 | 0.298070E+09 | 93054168.99 | 0.585738E+09 | 0.205147E+09 |
Annual Sum or Average | 0.281560E+10 | 0.154065E+10 | 0.127495E+10 | 0.390984E+10 | 0.184339E+10 |
Minimum of Months | 0.115089E+09 | 6693556.62 | 93054168.99 | 0.132188E+09 | 94150969.07 |
Maximum of Months | 0.391124E+09 | 0.298070E+09 | 0.119207E+09 | 0.585738E+09 | 0.214183E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_1_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 69948707.76 | 0.00 | 69948707.76 | 38794615.61 | 0.270812E+09 |
February | 79307152.05 | 0.00 | 79307152.05 | 40700391.98 | 0.220049E+09 |
March | 0.107607E+09 | 955.51 | 0.107606E+09 | 69326313.78 | 0.248983E+09 |
April | 0.120599E+09 | 963208.75 | 0.119636E+09 | 0.102558E+09 | 0.176795E+09 |
May | 0.149900E+09 | 7792510.18 | 0.142107E+09 | 0.130213E+09 | 0.156750E+09 |
June | 0.153759E+09 | 15155975.00 | 0.138603E+09 | 0.159883E+09 | 0.107560E+09 |
July | 0.150499E+09 | 12734522.95 | 0.137764E+09 | 0.177410E+09 | 94727124.00 |
August | 0.125148E+09 | 2764775.97 | 0.122383E+09 | 0.151581E+09 | 0.102023E+09 |
September | 0.102245E+09 | 19868.83 | 0.102225E+09 | 0.115767E+09 | 0.120879E+09 |
October | 83798531.60 | 0.00 | 83798531.60 | 0.104541E+09 | 0.147363E+09 |
November | 73426042.91 | 0.00 | 73426042.91 | 45485627.20 | 0.229337E+09 |
December | 65116278.60 | 0.00 | 65116278.60 | 34974906.23 | 0.270392E+09 |
Annual Sum or Average | 0.128135E+10 | 39431817.19 | 0.124192E+10 | 0.117123E+10 | 0.214567E+10 |
Minimum of Months | 65116278.60 | 0.00 | 65116278.60 | 34974906.23 | 94727124.00 |
Maximum of Months | 0.153759E+09 | 15155975.00 | 0.142107E+09 | 0.177410E+09 | 0.270812E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_2_NORTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 62583373.87 | 0.00 | 62583373.87 | 34709689.57 | 0.242281E+09 |
February | 70956409.44 | 0.00 | 70956409.44 | 36414794.92 | 0.196879E+09 |
March | 96276542.82 | 854.90 | 96275687.92 | 62026515.61 | 0.222766E+09 |
April | 0.107900E+09 | 861786.52 | 0.107038E+09 | 91758602.26 | 0.158179E+09 |
May | 0.134116E+09 | 6971988.39 | 0.127144E+09 | 0.116502E+09 | 0.140245E+09 |
June | 0.137569E+09 | 13560108.26 | 0.124009E+09 | 0.143048E+09 | 96234584.03 |
July | 0.134652E+09 | 11393625.94 | 0.123258E+09 | 0.158730E+09 | 84752716.76 |
August | 0.111970E+09 | 2473655.54 | 0.109497E+09 | 0.135620E+09 | 91280524.30 |
September | 91478618.90 | 17776.71 | 91460842.19 | 0.103577E+09 | 0.108151E+09 |
October | 74974863.74 | 0.00 | 74974863.74 | 93533107.93 | 0.131847E+09 |
November | 65694558.80 | 0.00 | 65694558.80 | 40696163.00 | 0.205187E+09 |
December | 58259781.19 | 0.00 | 58259781.19 | 31292181.13 | 0.241898E+09 |
Annual Sum or Average | 0.114643E+10 | 35279796.25 | 0.111115E+10 | 0.104791E+10 | 0.191970E+10 |
Minimum of Months | 58259781.19 | 0.00 | 58259781.19 | 31292181.13 | 84752716.76 |
Maximum of Months | 0.137569E+09 | 13560108.26 | 0.127144E+09 | 0.158730E+09 | 0.242281E+09 |
Report: WindowEnergyReportMonthly
For: CORRIDOR_FLR_6_WALL_2_SOUTH_WINDOW
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.136453E+10 | 0.100186E+10 | 0.362665E+09 | 0.196655E+10 | 0.718924E+09 |
February | 0.973464E+09 | 0.602415E+09 | 0.371049E+09 | 0.127286E+10 | 0.605016E+09 |
March | 0.859298E+09 | 0.418520E+09 | 0.440778E+09 | 0.103528E+10 | 0.714522E+09 |
April | 0.695176E+09 | 0.268506E+09 | 0.426670E+09 | 0.790289E+09 | 0.532727E+09 |
May | 0.506119E+09 | 61084215.77 | 0.445035E+09 | 0.483639E+09 | 0.497717E+09 |
June | 0.429663E+09 | 24989041.45 | 0.404674E+09 | 0.448338E+09 | 0.347937E+09 |
July | 0.468169E+09 | 49790186.24 | 0.418379E+09 | 0.548726E+09 | 0.300367E+09 |
August | 0.601368E+09 | 0.186647E+09 | 0.414722E+09 | 0.759946E+09 | 0.312704E+09 |
September | 0.799338E+09 | 0.396979E+09 | 0.402360E+09 | 0.110212E+10 | 0.357400E+09 |
October | 0.108202E+10 | 0.726695E+09 | 0.355325E+09 | 0.164711E+10 | 0.415124E+09 |
November | 0.127214E+10 | 0.901438E+09 | 0.370698E+09 | 0.181881E+10 | 0.617211E+09 |
December | 0.146018E+10 | 0.111278E+10 | 0.347399E+09 | 0.213109E+10 | 0.711828E+09 |
Annual Sum or Average | 0.105115E+11 | 0.575170E+10 | 0.475975E+10 | 0.140048E+11 | 0.613148E+10 |
Minimum of Months | 0.429663E+09 | 24989041.45 | 0.347399E+09 | 0.448338E+09 | 0.300367E+09 |
Maximum of Months | 0.146018E+10 | 0.111278E+10 | 0.445035E+09 | 0.213109E+10 | 0.718924E+09 |
Report: WindowZoneSummaryMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 981.86 | 358.16 | 691.03 | 507.37 | 183.66 | 0.00 | 0.00 |
February | 713.97 | 326.63 | 545.81 | 337.77 | 208.04 | 0.00 | 0.00 |
March | 530.24 | 339.89 | 435.17 | 211.95 | 223.22 | 0.00 | 0.00 |
April | 419.24 | 263.04 | 363.79 | 140.51 | 223.28 | 0.00 | 0.00 |
May | 255.38 | 232.89 | 256.31 | 30.93 | 225.38 | 0.00 | 0.00 |
June | 245.21 | 167.08 | 224.85 | 13.08 | 211.77 | 0.00 | 0.00 |
July | 287.09 | 138.22 | 237.09 | 25.22 | 211.88 | 0.00 | 0.00 |
August | 390.07 | 145.99 | 304.55 | 94.52 | 210.03 | 0.00 | 0.00 |
September | 574.55 | 181.59 | 418.30 | 207.74 | 210.56 | 0.00 | 0.00 |
October | 823.92 | 210.02 | 547.96 | 368.02 | 179.95 | 0.00 | 0.00 |
November | 941.08 | 320.73 | 665.72 | 471.73 | 193.99 | 0.00 | 0.00 |
December | 1063.27 | 359.32 | 739.48 | 563.54 | 175.93 | 0.00 | 0.00 |
Annual Sum or Average | 601.86 | 253.26 | 452.12 | 247.39 | 204.72 | 0.00 | 0.00 |
Minimum of Months | 245.21 | 138.22 | 224.85 | 13.08 | 175.93 | 0.00 | 0.00 |
Maximum of Months | 1063.27 | 359.32 | 739.48 | 563.54 | 225.38 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 2732.15 | 1088.28 | 1945.91 | 1428.72 | 517.18 | 0.00 | 0.00 |
February | 1976.58 | 1009.77 | 1536.96 | 951.13 | 585.83 | 0.00 | 0.00 |
March | 1464.23 | 1037.78 | 1225.42 | 596.84 | 628.58 | 0.00 | 0.00 |
April | 1151.94 | 823.87 | 1024.41 | 395.67 | 628.74 | 0.00 | 0.00 |
May | 690.48 | 729.68 | 721.76 | 87.11 | 634.65 | 0.00 | 0.00 |
June | 659.89 | 537.43 | 633.15 | 36.82 | 596.33 | 0.00 | 0.00 |
July | 778.03 | 448.82 | 667.64 | 71.00 | 596.64 | 0.00 | 0.00 |
August | 1071.81 | 476.10 | 857.59 | 266.17 | 591.42 | 0.00 | 0.00 |
September | 1593.09 | 584.72 | 1177.91 | 584.99 | 592.92 | 0.00 | 0.00 |
October | 2292.48 | 666.57 | 1543.03 | 1036.32 | 506.72 | 0.00 | 0.00 |
November | 2612.57 | 993.05 | 1874.62 | 1328.36 | 546.26 | 0.00 | 0.00 |
December | 2958.36 | 1094.88 | 2082.32 | 1586.90 | 495.41 | 0.00 | 0.00 |
Annual Sum or Average | 1664.34 | 789.73 | 1273.13 | 696.64 | 576.49 | 0.00 | 0.00 |
Minimum of Months | 659.89 | 448.82 | 633.15 | 36.82 | 495.41 | 0.00 | 0.00 |
Maximum of Months | 2958.36 | 1094.88 | 2082.32 | 1586.90 | 634.65 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 3646.19 | 1432.07 | 2527.84 | 1855.99 | 671.85 | 0.00 | 0.00 |
February | 2631.84 | 1350.90 | 1996.60 | 1235.57 | 761.03 | 0.00 | 0.00 |
March | 1943.96 | 1403.06 | 1591.89 | 775.33 | 816.56 | 0.00 | 0.00 |
April | 1528.07 | 1113.64 | 1330.77 | 514.00 | 816.77 | 0.00 | 0.00 |
May | 908.09 | 1000.33 | 937.61 | 113.16 | 824.45 | 0.00 | 0.00 |
June | 871.13 | 735.52 | 822.50 | 47.84 | 774.67 | 0.00 | 0.00 |
July | 1033.74 | 609.77 | 867.30 | 92.24 | 775.06 | 0.00 | 0.00 |
August | 1429.99 | 635.05 | 1114.06 | 345.77 | 768.29 | 0.00 | 0.00 |
September | 2127.48 | 772.78 | 1530.17 | 759.93 | 770.23 | 0.00 | 0.00 |
October | 3064.89 | 866.42 | 2004.49 | 1346.23 | 658.25 | 0.00 | 0.00 |
November | 3483.55 | 1308.78 | 2435.24 | 1725.62 | 709.62 | 0.00 | 0.00 |
December | 3949.17 | 1438.69 | 2705.05 | 2061.48 | 643.57 | 0.00 | 0.00 |
Annual Sum or Average | 2217.14 | 1053.96 | 1653.86 | 904.97 | 748.90 | 0.00 | 0.00 |
Minimum of Months | 871.13 | 609.77 | 822.50 | 47.84 | 643.57 | 0.00 | 0.00 |
Maximum of Months | 3949.17 | 1438.69 | 2705.05 | 2061.48 | 824.45 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 300.90 | 206.81 | 235.13 | 149.93 | 85.21 | 0.00 | 0.00 |
February | 269.09 | 188.14 | 225.67 | 121.17 | 104.50 | 0.00 | 0.00 |
March | 257.03 | 196.37 | 220.81 | 101.46 | 119.35 | 0.00 | 0.00 |
April | 325.69 | 149.77 | 257.75 | 124.41 | 133.34 | 0.00 | 0.00 |
May | 283.26 | 133.17 | 233.25 | 90.35 | 142.90 | 0.00 | 0.00 |
June | 313.32 | 93.64 | 237.83 | 99.18 | 138.65 | 0.00 | 0.00 |
July | 355.62 | 76.83 | 251.64 | 114.48 | 137.16 | 0.00 | 0.00 |
August | 360.76 | 80.87 | 252.33 | 122.74 | 129.58 | 0.00 | 0.00 |
September | 347.08 | 99.53 | 247.29 | 129.13 | 118.17 | 0.00 | 0.00 |
October | 348.21 | 114.19 | 234.67 | 141.95 | 92.72 | 0.00 | 0.00 |
November | 318.06 | 182.20 | 245.23 | 152.68 | 92.55 | 0.00 | 0.00 |
December | 320.16 | 204.91 | 246.07 | 164.75 | 81.32 | 0.00 | 0.00 |
Annual Sum or Average | 316.89 | 143.64 | 240.69 | 126.05 | 114.64 | 0.00 | 0.00 |
Minimum of Months | 257.03 | 76.83 | 220.81 | 90.35 | 81.32 | 0.00 | 0.00 |
Maximum of Months | 360.76 | 206.81 | 257.75 | 164.75 | 142.90 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 129.11 | 212.34 | 119.39 | 49.81 | 69.57 | 0.00 | 0.00 |
February | 149.04 | 189.89 | 143.84 | 54.53 | 89.31 | 0.00 | 0.00 |
March | 178.79 | 195.70 | 166.64 | 59.64 | 107.00 | 0.00 | 0.00 |
April | 279.08 | 147.66 | 222.68 | 96.98 | 125.70 | 0.00 | 0.00 |
May | 275.15 | 130.49 | 226.83 | 86.54 | 140.29 | 0.00 | 0.00 |
June | 316.76 | 91.52 | 240.27 | 101.21 | 139.06 | 0.00 | 0.00 |
July | 354.22 | 75.52 | 249.19 | 113.25 | 135.93 | 0.00 | 0.00 |
August | 331.83 | 79.44 | 229.10 | 104.91 | 124.19 | 0.00 | 0.00 |
September | 272.40 | 97.56 | 195.88 | 88.14 | 107.74 | 0.00 | 0.00 |
October | 220.29 | 113.54 | 151.23 | 69.34 | 81.89 | 0.00 | 0.00 |
November | 154.25 | 185.16 | 136.22 | 59.60 | 76.62 | 0.00 | 0.00 |
December | 131.73 | 211.37 | 119.35 | 53.56 | 65.79 | 0.00 | 0.00 |
Annual Sum or Average | 233.16 | 143.96 | 183.54 | 78.23 | 105.31 | 0.00 | 0.00 |
Minimum of Months | 129.11 | 75.52 | 119.35 | 49.81 | 65.79 | 0.00 | 0.00 |
Maximum of Months | 354.22 | 212.34 | 249.19 | 113.25 | 140.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 152.77 | 65.72 | 109.06 | 80.07 | 28.99 | 0.00 | 0.00 |
February | 109.04 | 60.56 | 86.14 | 53.31 | 32.83 | 0.00 | 0.00 |
March | 80.16 | 62.22 | 68.68 | 33.45 | 35.23 | 0.00 | 0.00 |
April | 62.80 | 48.88 | 57.41 | 22.18 | 35.24 | 0.00 | 0.00 |
May | 38.10 | 41.37 | 40.45 | 4.88 | 35.57 | 0.00 | 0.00 |
June | 36.87 | 29.61 | 35.49 | 2.06 | 33.42 | 0.00 | 0.00 |
July | 41.99 | 26.76 | 37.42 | 3.98 | 33.44 | 0.00 | 0.00 |
August | 57.67 | 29.58 | 48.06 | 14.92 | 33.15 | 0.00 | 0.00 |
September | 87.41 | 35.91 | 66.02 | 32.79 | 33.23 | 0.00 | 0.00 |
October | 127.99 | 39.87 | 86.48 | 58.08 | 28.40 | 0.00 | 0.00 |
November | 145.74 | 59.62 | 105.06 | 74.45 | 30.62 | 0.00 | 0.00 |
December | 165.68 | 65.96 | 116.70 | 88.94 | 27.77 | 0.00 | 0.00 |
Annual Sum or Average | 92.15 | 47.10 | 71.35 | 39.04 | 32.31 | 0.00 | 0.00 |
Minimum of Months | 36.87 | 26.76 | 35.49 | 2.06 | 27.77 | 0.00 | 0.00 |
Maximum of Months | 165.68 | 65.96 | 116.70 | 88.94 | 35.57 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 11.01 | 61.67 | 16.49 | 0.00 | 16.49 | 0.00 | 0.00 |
February | 12.40 | 55.55 | 20.69 | 0.00 | 20.69 | 0.00 | 0.00 |
March | 18.13 | 57.18 | 25.36 | 0.00 | 25.36 | 0.00 | 0.00 |
April | 27.18 | 41.34 | 29.37 | 0.23 | 29.14 | 0.00 | 0.00 |
May | 32.57 | 35.63 | 35.33 | 1.84 | 33.49 | 0.00 | 0.00 |
June | 41.37 | 24.46 | 37.45 | 3.69 | 33.76 | 0.00 | 0.00 |
July | 45.06 | 19.92 | 35.47 | 3.00 | 32.47 | 0.00 | 0.00 |
August | 39.12 | 21.01 | 29.50 | 0.65 | 28.84 | 0.00 | 0.00 |
September | 30.79 | 26.94 | 24.90 | 0.00 | 24.90 | 0.00 | 0.00 |
October | 27.43 | 31.64 | 19.75 | 0.00 | 19.75 | 0.00 | 0.00 |
November | 13.16 | 53.56 | 17.88 | 0.00 | 17.88 | 0.00 | 0.00 |
December | 10.21 | 61.46 | 15.35 | 0.00 | 15.35 | 0.00 | 0.00 |
Annual Sum or Average | 25.79 | 40.79 | 25.65 | 0.79 | 24.86 | 0.00 | 0.00 |
Minimum of Months | 10.21 | 19.92 | 15.35 | 0.00 | 15.35 | 0.00 | 0.00 |
Maximum of Months | 45.06 | 61.67 | 37.45 | 3.69 | 33.76 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 304.53 | 201.95 | 240.01 | 155.50 | 84.51 | 0.00 | 0.00 |
February | 250.62 | 182.72 | 217.08 | 116.70 | 100.38 | 0.00 | 0.00 |
March | 248.31 | 188.68 | 219.38 | 101.46 | 117.92 | 0.00 | 0.00 |
April | 296.33 | 143.86 | 241.96 | 113.12 | 128.85 | 0.00 | 0.00 |
May | 246.26 | 128.41 | 210.86 | 72.90 | 137.96 | 0.00 | 0.00 |
June | 260.18 | 92.38 | 203.84 | 71.81 | 132.03 | 0.00 | 0.00 |
July | 317.12 | 76.64 | 227.37 | 94.69 | 132.68 | 0.00 | 0.00 |
August | 337.86 | 78.85 | 238.59 | 113.52 | 125.07 | 0.00 | 0.00 |
September | 292.36 | 97.27 | 212.86 | 100.94 | 111.92 | 0.00 | 0.00 |
October | 326.38 | 109.97 | 222.97 | 131.56 | 91.41 | 0.00 | 0.00 |
November | 300.10 | 177.81 | 235.81 | 145.96 | 89.85 | 0.00 | 0.00 |
December | 316.50 | 200.77 | 246.32 | 167.16 | 79.16 | 0.00 | 0.00 |
Annual Sum or Average | 291.76 | 139.72 | 226.53 | 115.51 | 111.01 | 0.00 | 0.00 |
Minimum of Months | 246.26 | 76.64 | 203.84 | 71.81 | 79.16 | 0.00 | 0.00 |
Maximum of Months | 337.86 | 201.95 | 246.32 | 167.16 | 137.96 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 125.65 | 199.45 | 124.27 | 55.39 | 68.88 | 0.00 | 0.00 |
February | 127.72 | 180.88 | 135.25 | 50.05 | 85.20 | 0.00 | 0.00 |
March | 168.69 | 186.35 | 165.21 | 59.64 | 105.57 | 0.00 | 0.00 |
April | 249.38 | 141.10 | 206.89 | 85.69 | 121.20 | 0.00 | 0.00 |
May | 238.34 | 125.80 | 204.44 | 69.09 | 135.35 | 0.00 | 0.00 |
June | 262.77 | 89.30 | 206.27 | 73.84 | 132.43 | 0.00 | 0.00 |
July | 314.62 | 74.18 | 224.92 | 93.47 | 131.46 | 0.00 | 0.00 |
August | 308.54 | 77.07 | 215.36 | 95.68 | 119.68 | 0.00 | 0.00 |
September | 218.00 | 94.90 | 161.44 | 59.95 | 101.49 | 0.00 | 0.00 |
October | 196.87 | 107.45 | 139.53 | 58.95 | 80.59 | 0.00 | 0.00 |
November | 132.46 | 175.35 | 126.80 | 52.88 | 73.92 | 0.00 | 0.00 |
December | 120.25 | 198.21 | 119.59 | 55.96 | 63.63 | 0.00 | 0.00 |
Annual Sum or Average | 205.80 | 137.28 | 169.38 | 67.69 | 101.69 | 0.00 | 0.00 |
Minimum of Months | 120.25 | 74.18 | 119.59 | 50.05 | 63.63 | 0.00 | 0.00 |
Maximum of Months | 314.62 | 199.45 | 224.92 | 95.68 | 135.35 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 362.01 | 243.64 | 272.01 | 173.50 | 98.52 | 0.00 | 0.00 |
February | 274.32 | 225.13 | 231.47 | 115.50 | 115.97 | 0.00 | 0.00 |
March | 224.86 | 238.67 | 203.75 | 72.48 | 131.27 | 0.00 | 0.00 |
April | 210.08 | 176.54 | 188.03 | 48.56 | 139.47 | 0.00 | 0.00 |
May | 164.43 | 154.40 | 164.18 | 14.56 | 149.62 | 0.00 | 0.00 |
June | 181.07 | 104.52 | 158.01 | 12.47 | 145.54 | 0.00 | 0.00 |
July | 207.07 | 83.85 | 157.92 | 15.12 | 142.79 | 0.00 | 0.00 |
August | 231.13 | 88.61 | 168.04 | 33.73 | 134.30 | 0.00 | 0.00 |
September | 275.41 | 113.41 | 196.98 | 71.05 | 125.93 | 0.00 | 0.00 |
October | 354.19 | 129.94 | 230.16 | 125.84 | 104.32 | 0.00 | 0.00 |
November | 355.89 | 213.89 | 266.38 | 161.31 | 105.07 | 0.00 | 0.00 |
December | 388.19 | 241.29 | 286.11 | 192.70 | 93.41 | 0.00 | 0.00 |
Annual Sum or Average | 269.16 | 167.53 | 210.17 | 86.31 | 123.86 | 0.00 | 0.00 |
Minimum of Months | 164.43 | 83.85 | 157.92 | 12.47 | 93.41 | 0.00 | 0.00 |
Maximum of Months | 388.19 | 243.64 | 286.11 | 192.70 | 149.62 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 298.45 | 205.66 | 235.33 | 150.05 | 85.28 | 0.00 | 0.00 |
February | 265.75 | 187.14 | 225.86 | 121.27 | 104.58 | 0.00 | 0.00 |
March | 253.01 | 195.97 | 220.99 | 101.54 | 119.45 | 0.00 | 0.00 |
April | 319.38 | 150.03 | 257.96 | 124.51 | 133.45 | 0.00 | 0.00 |
May | 276.64 | 133.70 | 233.44 | 90.42 | 143.01 | 0.00 | 0.00 |
June | 305.79 | 94.36 | 238.02 | 99.26 | 138.77 | 0.00 | 0.00 |
July | 348.10 | 77.72 | 251.84 | 114.57 | 137.27 | 0.00 | 0.00 |
August | 353.75 | 81.92 | 252.53 | 122.84 | 129.69 | 0.00 | 0.00 |
September | 341.02 | 100.18 | 247.50 | 129.23 | 118.27 | 0.00 | 0.00 |
October | 343.91 | 114.38 | 234.86 | 142.07 | 92.79 | 0.00 | 0.00 |
November | 314.67 | 181.43 | 245.43 | 152.81 | 92.62 | 0.00 | 0.00 |
December | 317.74 | 203.54 | 246.28 | 164.89 | 81.39 | 0.00 | 0.00 |
Annual Sum or Average | 311.80 | 143.62 | 240.89 | 126.16 | 114.73 | 0.00 | 0.00 |
Minimum of Months | 253.01 | 77.72 | 220.99 | 90.42 | 81.39 | 0.00 | 0.00 |
Maximum of Months | 353.75 | 205.66 | 257.96 | 164.89 | 143.01 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 128.16 | 209.94 | 119.48 | 49.86 | 69.63 | 0.00 | 0.00 |
February | 147.19 | 188.08 | 143.96 | 54.57 | 89.39 | 0.00 | 0.00 |
March | 175.61 | 194.78 | 166.77 | 59.69 | 107.09 | 0.00 | 0.00 |
April | 273.05 | 147.69 | 222.86 | 97.06 | 125.80 | 0.00 | 0.00 |
May | 268.47 | 130.87 | 227.01 | 86.61 | 140.40 | 0.00 | 0.00 |
June | 309.02 | 92.20 | 240.46 | 101.29 | 139.17 | 0.00 | 0.00 |
July | 346.44 | 76.37 | 249.39 | 113.35 | 136.04 | 0.00 | 0.00 |
August | 324.56 | 80.44 | 229.29 | 104.99 | 124.30 | 0.00 | 0.00 |
September | 266.61 | 98.06 | 196.04 | 88.21 | 107.83 | 0.00 | 0.00 |
October | 216.83 | 113.34 | 151.36 | 69.39 | 81.96 | 0.00 | 0.00 |
November | 152.50 | 183.40 | 136.34 | 59.65 | 76.68 | 0.00 | 0.00 |
December | 131.12 | 208.66 | 119.44 | 53.60 | 65.84 | 0.00 | 0.00 |
Annual Sum or Average | 228.72 | 143.43 | 183.69 | 78.29 | 105.40 | 0.00 | 0.00 |
Minimum of Months | 128.16 | 76.37 | 119.44 | 49.86 | 65.84 | 0.00 | 0.00 |
Maximum of Months | 346.44 | 209.94 | 249.39 | 113.35 | 140.40 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 281.03 | 107.44 | 200.14 | 146.94 | 53.19 | 0.00 | 0.00 |
February | 201.28 | 98.07 | 158.08 | 97.82 | 60.25 | 0.00 | 0.00 |
March | 148.17 | 103.73 | 126.03 | 61.38 | 64.65 | 0.00 | 0.00 |
April | 116.75 | 78.78 | 105.36 | 40.69 | 64.67 | 0.00 | 0.00 |
May | 70.34 | 69.93 | 74.23 | 8.96 | 65.27 | 0.00 | 0.00 |
June | 68.08 | 48.98 | 65.12 | 3.79 | 61.33 | 0.00 | 0.00 |
July | 80.84 | 39.61 | 68.67 | 7.30 | 61.36 | 0.00 | 0.00 |
August | 110.57 | 41.65 | 88.20 | 27.38 | 60.83 | 0.00 | 0.00 |
September | 163.35 | 52.10 | 121.15 | 60.17 | 60.98 | 0.00 | 0.00 |
October | 237.35 | 58.98 | 158.70 | 106.58 | 52.12 | 0.00 | 0.00 |
November | 268.70 | 94.78 | 192.80 | 136.62 | 56.18 | 0.00 | 0.00 |
December | 304.81 | 106.55 | 214.17 | 163.21 | 50.95 | 0.00 | 0.00 |
Annual Sum or Average | 170.87 | 74.93 | 130.94 | 71.65 | 59.29 | 0.00 | 0.00 |
Minimum of Months | 68.08 | 39.61 | 65.12 | 3.79 | 50.95 | 0.00 | 0.00 |
Maximum of Months | 304.81 | 107.44 | 214.17 | 163.21 | 65.27 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 68.14 | 643.41 | 144.35 | 0.00 | 144.35 | 0.00 | 0.00 |
February | 73.88 | 603.54 | 181.19 | 0.00 | 181.19 | 0.00 | 0.00 |
March | 117.88 | 609.15 | 222.06 | 0.00 | 222.05 | 0.00 | 0.00 |
April | 185.85 | 458.15 | 257.16 | 2.05 | 255.11 | 0.00 | 0.00 |
May | 223.91 | 398.63 | 309.33 | 16.08 | 293.25 | 0.00 | 0.00 |
June | 294.33 | 289.51 | 327.87 | 32.32 | 295.55 | 0.00 | 0.00 |
July | 326.81 | 246.36 | 310.57 | 26.28 | 284.29 | 0.00 | 0.00 |
August | 283.55 | 267.71 | 258.25 | 5.71 | 252.55 | 0.00 | 0.00 |
September | 221.52 | 325.37 | 218.02 | 0.04 | 217.98 | 0.00 | 0.00 |
October | 199.30 | 373.46 | 172.93 | 0.00 | 172.93 | 0.00 | 0.00 |
November | 81.62 | 577.13 | 156.57 | 0.00 | 156.57 | 0.00 | 0.00 |
December | 61.88 | 645.25 | 134.37 | 0.00 | 134.37 | 0.00 | 0.00 |
Annual Sum or Average | 178.89 | 452.35 | 224.57 | 6.91 | 217.66 | 0.00 | 0.00 |
Minimum of Months | 61.88 | 246.36 | 134.37 | 0.00 | 134.37 | 0.00 | 0.00 |
Maximum of Months | 326.81 | 645.25 | 327.87 | 32.32 | 295.55 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 60.03 | 669.44 | 144.35 | 0.00 | 144.35 | 0.00 | 0.00 |
February | 64.63 | 629.63 | 181.19 | 0.00 | 181.19 | 0.00 | 0.00 |
March | 106.27 | 633.45 | 222.06 | 0.00 | 222.05 | 0.00 | 0.00 |
April | 171.25 | 476.86 | 257.16 | 2.05 | 255.11 | 0.00 | 0.00 |
May | 206.32 | 414.76 | 309.33 | 16.08 | 293.25 | 0.00 | 0.00 |
June | 275.43 | 302.46 | 327.87 | 32.32 | 295.55 | 0.00 | 0.00 |
July | 308.75 | 258.10 | 310.57 | 26.28 | 284.29 | 0.00 | 0.00 |
August | 267.91 | 281.49 | 258.25 | 5.71 | 252.55 | 0.00 | 0.00 |
September | 207.63 | 342.67 | 218.02 | 0.04 | 217.98 | 0.00 | 0.00 |
October | 187.37 | 392.17 | 172.93 | 0.00 | 172.93 | 0.00 | 0.00 |
November | 72.37 | 601.03 | 156.57 | 0.00 | 156.57 | 0.00 | 0.00 |
December | 54.31 | 671.57 | 134.37 | 0.00 | 134.37 | 0.00 | 0.00 |
Annual Sum or Average | 165.83 | 471.98 | 224.57 | 6.91 | 217.66 | 0.00 | 0.00 |
Minimum of Months | 54.31 | 258.10 | 134.37 | 0.00 | 134.37 | 0.00 | 0.00 |
Maximum of Months | 308.75 | 671.57 | 327.87 | 32.32 | 295.55 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 448.09 | 442.71 | 364.56 | 211.05 | 153.51 | 0.00 | 0.00 |
February | 385.61 | 432.49 | 352.61 | 166.88 | 185.73 | 0.00 | 0.00 |
March | 429.26 | 440.09 | 384.89 | 161.22 | 223.67 | 0.00 | 0.00 |
April | 574.34 | 342.23 | 449.20 | 198.96 | 250.24 | 0.00 | 0.00 |
May | 508.82 | 313.58 | 415.62 | 142.09 | 273.52 | 0.00 | 0.00 |
June | 558.49 | 233.58 | 410.42 | 145.76 | 264.67 | 0.00 | 0.00 |
July | 682.48 | 195.97 | 452.64 | 188.30 | 264.34 | 0.00 | 0.00 |
August | 696.39 | 202.74 | 454.29 | 209.35 | 244.94 | 0.00 | 0.00 |
September | 547.12 | 234.41 | 374.59 | 161.01 | 213.58 | 0.00 | 0.00 |
October | 557.50 | 261.10 | 362.79 | 190.66 | 172.13 | 0.00 | 0.00 |
November | 448.20 | 400.97 | 362.89 | 198.99 | 163.90 | 0.00 | 0.00 |
December | 452.66 | 441.80 | 366.20 | 223.30 | 142.90 | 0.00 | 0.00 |
Annual Sum or Average | 525.13 | 327.90 | 396.21 | 183.34 | 212.87 | 0.00 | 0.00 |
Minimum of Months | 385.61 | 195.97 | 352.61 | 142.09 | 142.90 | 0.00 | 0.00 |
Maximum of Months | 696.39 | 442.71 | 454.29 | 223.30 | 273.52 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 747.15 | 445.47 | 558.94 | 374.05 | 184.89 | 0.00 | 0.00 |
February | 550.82 | 415.23 | 464.50 | 249.01 | 215.49 | 0.00 | 0.00 |
March | 433.43 | 440.76 | 396.95 | 156.26 | 240.69 | 0.00 | 0.00 |
April | 379.70 | 334.60 | 356.36 | 104.29 | 252.06 | 0.00 | 0.00 |
May | 271.15 | 295.18 | 295.00 | 28.32 | 266.68 | 0.00 | 0.00 |
June | 285.82 | 208.84 | 278.16 | 20.72 | 257.44 | 0.00 | 0.00 |
July | 327.44 | 176.22 | 281.26 | 27.60 | 253.66 | 0.00 | 0.00 |
August | 390.50 | 188.46 | 313.05 | 71.64 | 241.41 | 0.00 | 0.00 |
September | 509.78 | 226.20 | 383.13 | 153.17 | 229.96 | 0.00 | 0.00 |
October | 686.29 | 256.61 | 463.26 | 271.32 | 191.94 | 0.00 | 0.00 |
November | 724.79 | 395.60 | 544.47 | 347.78 | 196.69 | 0.00 | 0.00 |
December | 804.45 | 441.08 | 591.23 | 415.47 | 175.77 | 0.00 | 0.00 |
Annual Sum or Average | 509.31 | 318.19 | 410.30 | 184.75 | 225.55 | 0.00 | 0.00 |
Minimum of Months | 271.15 | 176.22 | 278.16 | 20.72 | 175.77 | 0.00 | 0.00 |
Maximum of Months | 804.45 | 445.47 | 591.23 | 415.47 | 266.68 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.262981E+10 | 0.959297E+09 | 0.185087E+10 | 0.135894E+10 | 0.491925E+09 | 0.00 | 0.00 |
February | 0.172725E+10 | 0.790192E+09 | 0.132042E+10 | 0.817125E+09 | 0.503297E+09 | 0.00 | 0.00 |
March | 0.142019E+10 | 0.910353E+09 | 0.116557E+10 | 0.567687E+09 | 0.597878E+09 | 0.00 | 0.00 |
April | 0.108668E+10 | 0.681792E+09 | 0.942948E+09 | 0.364206E+09 | 0.578742E+09 | 0.00 | 0.00 |
May | 0.684022E+09 | 0.623784E+09 | 0.686508E+09 | 82855603.57 | 0.603653E+09 | 0.00 | 0.00 |
June | 0.635575E+09 | 0.433074E+09 | 0.582802E+09 | 33895534.00 | 0.548907E+09 | 0.00 | 0.00 |
July | 0.768941E+09 | 0.370200E+09 | 0.635032E+09 | 67536201.96 | 0.567496E+09 | 0.00 | 0.00 |
August | 0.104476E+10 | 0.391032E+09 | 0.815705E+09 | 0.253170E+09 | 0.562535E+09 | 0.00 | 0.00 |
September | 0.148924E+10 | 0.470673E+09 | 0.108424E+10 | 0.538468E+09 | 0.545767E+09 | 0.00 | 0.00 |
October | 0.220679E+10 | 0.562515E+09 | 0.146767E+10 | 0.985700E+09 | 0.481969E+09 | 0.00 | 0.00 |
November | 0.243929E+10 | 0.831345E+09 | 0.172555E+10 | 0.122273E+10 | 0.502820E+09 | 0.00 | 0.00 |
December | 0.284786E+10 | 0.962409E+09 | 0.198061E+10 | 0.150940E+10 | 0.471217E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.189804E+11 | 0.798667E+10 | 0.142579E+11 | 0.780170E+10 | 0.645621E+10 | 0.00 | 0.00 |
Minimum of Months | 0.635575E+09 | 0.370200E+09 | 0.582802E+09 | 33895534.00 | 0.471217E+09 | 0.00 | 0.00 |
Maximum of Months | 0.284786E+10 | 0.962409E+09 | 0.198061E+10 | 0.150940E+10 | 0.603653E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.731778E+10 | 0.291485E+10 | 0.521191E+10 | 0.382669E+10 | 0.138523E+10 | 0.00 | 0.00 |
February | 0.478174E+10 | 0.244284E+10 | 0.371822E+10 | 0.230097E+10 | 0.141725E+10 | 0.00 | 0.00 |
March | 0.392180E+10 | 0.277960E+10 | 0.328216E+10 | 0.159857E+10 | 0.168359E+10 | 0.00 | 0.00 |
April | 0.298583E+10 | 0.213546E+10 | 0.265528E+10 | 0.102558E+10 | 0.162970E+10 | 0.00 | 0.00 |
May | 0.184938E+10 | 0.195436E+10 | 0.193316E+10 | 0.233316E+09 | 0.169985E+10 | 0.00 | 0.00 |
June | 0.171043E+10 | 0.139301E+10 | 0.164113E+10 | 95447588.87 | 0.154569E+10 | 0.00 | 0.00 |
July | 0.208388E+10 | 0.120211E+10 | 0.178821E+10 | 0.190177E+09 | 0.159803E+10 | 0.00 | 0.00 |
August | 0.287074E+10 | 0.127520E+10 | 0.229697E+10 | 0.712911E+09 | 0.158406E+10 | 0.00 | 0.00 |
September | 0.412929E+10 | 0.151560E+10 | 0.305313E+10 | 0.151629E+10 | 0.153684E+10 | 0.00 | 0.00 |
October | 0.614017E+10 | 0.178534E+10 | 0.413286E+10 | 0.277567E+10 | 0.135719E+10 | 0.00 | 0.00 |
November | 0.677178E+10 | 0.257399E+10 | 0.485902E+10 | 0.344311E+10 | 0.141591E+10 | 0.00 | 0.00 |
December | 0.792367E+10 | 0.293253E+10 | 0.557728E+10 | 0.425036E+10 | 0.132692E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.524865E+11 | 0.249049E+11 | 0.401493E+11 | 0.219691E+11 | 0.181803E+11 | 0.00 | 0.00 |
Minimum of Months | 0.171043E+10 | 0.120211E+10 | 0.164113E+10 | 95447588.87 | 0.132692E+10 | 0.00 | 0.00 |
Maximum of Months | 0.792367E+10 | 0.293253E+10 | 0.557728E+10 | 0.425036E+10 | 0.169985E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.976596E+10 | 0.383565E+10 | 0.677057E+10 | 0.497108E+10 | 0.179949E+10 | 0.00 | 0.00 |
February | 0.636695E+10 | 0.326810E+10 | 0.483018E+10 | 0.298909E+10 | 0.184109E+10 | 0.00 | 0.00 |
March | 0.520671E+10 | 0.375795E+10 | 0.426371E+10 | 0.207663E+10 | 0.218707E+10 | 0.00 | 0.00 |
April | 0.396077E+10 | 0.288657E+10 | 0.344936E+10 | 0.133229E+10 | 0.211707E+10 | 0.00 | 0.00 |
May | 0.243222E+10 | 0.267928E+10 | 0.251129E+10 | 0.303091E+09 | 0.220820E+10 | 0.00 | 0.00 |
June | 0.225797E+10 | 0.190647E+10 | 0.213192E+10 | 0.123992E+09 | 0.200793E+10 | 0.00 | 0.00 |
July | 0.276877E+10 | 0.163322E+10 | 0.232298E+10 | 0.247051E+09 | 0.207593E+10 | 0.00 | 0.00 |
August | 0.383010E+10 | 0.170093E+10 | 0.298390E+10 | 0.926112E+09 | 0.205779E+10 | 0.00 | 0.00 |
September | 0.551442E+10 | 0.200305E+10 | 0.396620E+10 | 0.196975E+10 | 0.199645E+10 | 0.00 | 0.00 |
October | 0.820899E+10 | 0.232062E+10 | 0.536882E+10 | 0.360575E+10 | 0.176307E+10 | 0.00 | 0.00 |
November | 0.902935E+10 | 0.339235E+10 | 0.631215E+10 | 0.447280E+10 | 0.183935E+10 | 0.00 | 0.00 |
December | 0.105775E+11 | 0.385338E+10 | 0.724520E+10 | 0.552146E+10 | 0.172374E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.699197E+11 | 0.332376E+11 | 0.521563E+11 | 0.285391E+11 | 0.236172E+11 | 0.00 | 0.00 |
Minimum of Months | 0.225797E+10 | 0.163322E+10 | 0.213192E+10 | 0.123992E+09 | 0.172374E+10 | 0.00 | 0.00 |
Maximum of Months | 0.105775E+11 | 0.385338E+10 | 0.724520E+10 | 0.552146E+10 | 0.220820E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.805941E+09 | 0.553928E+09 | 0.629779E+09 | 0.401562E+09 | 0.228218E+09 | 0.00 | 0.00 |
February | 0.650991E+09 | 0.455139E+09 | 0.545947E+09 | 0.293146E+09 | 0.252801E+09 | 0.00 | 0.00 |
March | 0.688431E+09 | 0.525966E+09 | 0.591405E+09 | 0.271742E+09 | 0.319663E+09 | 0.00 | 0.00 |
April | 0.844197E+09 | 0.388212E+09 | 0.668084E+09 | 0.322466E+09 | 0.345618E+09 | 0.00 | 0.00 |
May | 0.758693E+09 | 0.356689E+09 | 0.624730E+09 | 0.241994E+09 | 0.382735E+09 | 0.00 | 0.00 |
June | 0.812127E+09 | 0.242702E+09 | 0.616453E+09 | 0.257067E+09 | 0.359386E+09 | 0.00 | 0.00 |
July | 0.952505E+09 | 0.205788E+09 | 0.673982E+09 | 0.306615E+09 | 0.367367E+09 | 0.00 | 0.00 |
August | 0.966260E+09 | 0.216597E+09 | 0.675831E+09 | 0.328752E+09 | 0.347079E+09 | 0.00 | 0.00 |
September | 0.899631E+09 | 0.257990E+09 | 0.640987E+09 | 0.334692E+09 | 0.306295E+09 | 0.00 | 0.00 |
October | 0.932639E+09 | 0.305840E+09 | 0.628535E+09 | 0.380203E+09 | 0.248332E+09 | 0.00 | 0.00 |
November | 0.824400E+09 | 0.472270E+09 | 0.635637E+09 | 0.395756E+09 | 0.239881E+09 | 0.00 | 0.00 |
December | 0.857507E+09 | 0.548818E+09 | 0.659085E+09 | 0.441270E+09 | 0.217815E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.999332E+10 | 0.452994E+10 | 0.759045E+10 | 0.397526E+10 | 0.361519E+10 | 0.00 | 0.00 |
Minimum of Months | 0.650991E+09 | 0.205788E+09 | 0.545947E+09 | 0.241994E+09 | 0.217815E+09 | 0.00 | 0.00 |
Maximum of Months | 0.966260E+09 | 0.553928E+09 | 0.675831E+09 | 0.441270E+09 | 0.382735E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.345815E+09 | 0.568734E+09 | 0.319765E+09 | 0.133423E+09 | 0.186341E+09 | 0.00 | 0.00 |
February | 0.360567E+09 | 0.459392E+09 | 0.347980E+09 | 0.131915E+09 | 0.216064E+09 | 0.00 | 0.00 |
March | 0.478861E+09 | 0.524164E+09 | 0.446321E+09 | 0.159730E+09 | 0.286591E+09 | 0.00 | 0.00 |
April | 0.723364E+09 | 0.382727E+09 | 0.577175E+09 | 0.251363E+09 | 0.325813E+09 | 0.00 | 0.00 |
May | 0.736973E+09 | 0.349511E+09 | 0.607538E+09 | 0.231794E+09 | 0.375744E+09 | 0.00 | 0.00 |
June | 0.821033E+09 | 0.237222E+09 | 0.622769E+09 | 0.262337E+09 | 0.360433E+09 | 0.00 | 0.00 |
July | 0.948730E+09 | 0.202262E+09 | 0.667420E+09 | 0.303336E+09 | 0.364083E+09 | 0.00 | 0.00 |
August | 0.888786E+09 | 0.212766E+09 | 0.613618E+09 | 0.280979E+09 | 0.332639E+09 | 0.00 | 0.00 |
September | 0.706073E+09 | 0.252866E+09 | 0.507720E+09 | 0.228461E+09 | 0.279260E+09 | 0.00 | 0.00 |
October | 0.590018E+09 | 0.304107E+09 | 0.405058E+09 | 0.185711E+09 | 0.219347E+09 | 0.00 | 0.00 |
November | 0.399822E+09 | 0.479930E+09 | 0.353093E+09 | 0.154495E+09 | 0.198599E+09 | 0.00 | 0.00 |
December | 0.352821E+09 | 0.566141E+09 | 0.319656E+09 | 0.143444E+09 | 0.176212E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.735286E+10 | 0.453982E+10 | 0.578811E+10 | 0.246699E+10 | 0.332113E+10 | 0.00 | 0.00 |
Minimum of Months | 0.345815E+09 | 0.202262E+09 | 0.319656E+09 | 0.131915E+09 | 0.176212E+09 | 0.00 | 0.00 |
Maximum of Months | 0.948730E+09 | 0.568734E+09 | 0.667420E+09 | 0.303336E+09 | 0.375744E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.409185E+09 | 0.176020E+09 | 0.292103E+09 | 0.214468E+09 | 77635553.28 | 0.00 | 0.00 |
February | 0.263780E+09 | 0.146517E+09 | 0.208389E+09 | 0.128959E+09 | 79430304.49 | 0.00 | 0.00 |
March | 0.214696E+09 | 0.166648E+09 | 0.183949E+09 | 89592320.13 | 94357165.29 | 0.00 | 0.00 |
April | 0.162788E+09 | 0.126708E+09 | 0.148816E+09 | 57478930.01 | 91337075.93 | 0.00 | 0.00 |
May | 0.102045E+09 | 0.110798E+09 | 0.108345E+09 | 13076269.05 | 95268456.07 | 0.00 | 0.00 |
June | 95568521.62 | 76753128.71 | 91977834.87 | 5349392.23 | 86628442.64 | 0.00 | 0.00 |
July | 0.112476E+09 | 71676734.20 | 0.100221E+09 | 10658561.51 | 89562197.17 | 0.00 | 0.00 |
August | 0.154455E+09 | 79239824.81 | 0.128735E+09 | 39955329.25 | 88779244.96 | 0.00 | 0.00 |
September | 0.226556E+09 | 93079212.01 | 0.171114E+09 | 84981032.64 | 86132926.04 | 0.00 | 0.00 |
October | 0.342818E+09 | 0.106789E+09 | 0.231627E+09 | 0.155563E+09 | 76064301.16 | 0.00 | 0.00 |
November | 0.377749E+09 | 0.154537E+09 | 0.272326E+09 | 0.192970E+09 | 79355096.08 | 0.00 | 0.00 |
December | 0.443770E+09 | 0.176657E+09 | 0.312580E+09 | 0.238213E+09 | 74367526.37 | 0.00 | 0.00 |
Annual Sum or Average | 0.290588E+10 | 0.148542E+10 | 0.225018E+10 | 0.123126E+10 | 0.101892E+10 | 0.00 | 0.00 |
Minimum of Months | 95568521.62 | 71676734.20 | 91977834.87 | 5349392.23 | 74367526.37 | 0.00 | 0.00 |
Maximum of Months | 0.443770E+09 | 0.176657E+09 | 0.312580E+09 | 0.238213E+09 | 95268456.07 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 29492845.37 | 0.165185E+09 | 44155780.40 | 0.00 | 44155780.40 | 0.00 | 0.00 |
February | 29988247.66 | 0.134383E+09 | 50063386.48 | 0.00 | 50063386.48 | 0.00 | 0.00 |
March | 48551821.58 | 0.153163E+09 | 67928039.34 | 603.17 | 67927436.17 | 0.00 | 0.00 |
April | 70460195.97 | 0.107163E+09 | 76129071.72 | 608034.59 | 75521037.12 | 0.00 | 0.00 |
May | 87235539.49 | 95426638.52 | 94625527.60 | 4919095.43 | 89706432.17 | 0.00 | 0.00 |
June | 0.107244E+09 | 63404836.94 | 97061928.37 | 9567351.92 | 87494576.45 | 0.00 | 0.00 |
July | 0.120688E+09 | 53355523.01 | 95003827.50 | 8038787.52 | 86965039.98 | 0.00 | 0.00 |
August | 0.104783E+09 | 56260769.27 | 79000722.41 | 1745290.87 | 77255431.54 | 0.00 | 0.00 |
September | 79819879.62 | 69817711.06 | 64542857.91 | 12542.38 | 64530315.53 | 0.00 | 0.00 |
October | 73473002.78 | 84740504.50 | 52898612.11 | 0.00 | 52898612.11 | 0.00 | 0.00 |
November | 34101186.15 | 0.138829E+09 | 46350880.95 | 0.00 | 46350880.95 | 0.00 | 0.00 |
December | 27353049.46 | 0.164624E+09 | 41105263.99 | 0.00 | 41105263.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.813191E+09 | 0.128635E+10 | 0.808866E+09 | 24891705.89 | 0.783974E+09 | 0.00 | 0.00 |
Minimum of Months | 27353049.46 | 53355523.01 | 41105263.99 | 0.00 | 41105263.99 | 0.00 | 0.00 |
Maximum of Months | 0.120688E+09 | 0.165185E+09 | 97061928.37 | 9567351.92 | 89706432.17 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.815659E+09 | 0.540899E+09 | 0.642851E+09 | 0.416487E+09 | 0.226364E+09 | 0.00 | 0.00 |
February | 0.606295E+09 | 0.442026E+09 | 0.525168E+09 | 0.282321E+09 | 0.242847E+09 | 0.00 | 0.00 |
March | 0.665074E+09 | 0.505350E+09 | 0.587588E+09 | 0.271751E+09 | 0.315837E+09 | 0.00 | 0.00 |
April | 0.768080E+09 | 0.372888E+09 | 0.627173E+09 | 0.293206E+09 | 0.333967E+09 | 0.00 | 0.00 |
May | 0.659581E+09 | 0.343937E+09 | 0.564763E+09 | 0.195246E+09 | 0.369517E+09 | 0.00 | 0.00 |
June | 0.674398E+09 | 0.239457E+09 | 0.528345E+09 | 0.186126E+09 | 0.342220E+09 | 0.00 | 0.00 |
July | 0.849363E+09 | 0.205269E+09 | 0.608991E+09 | 0.253618E+09 | 0.355373E+09 | 0.00 | 0.00 |
August | 0.904918E+09 | 0.211197E+09 | 0.639029E+09 | 0.304040E+09 | 0.334990E+09 | 0.00 | 0.00 |
September | 0.757803E+09 | 0.252128E+09 | 0.551729E+09 | 0.261625E+09 | 0.290104E+09 | 0.00 | 0.00 |
October | 0.874189E+09 | 0.294537E+09 | 0.597208E+09 | 0.352380E+09 | 0.244828E+09 | 0.00 | 0.00 |
November | 0.777856E+09 | 0.460889E+09 | 0.611213E+09 | 0.378322E+09 | 0.232891E+09 | 0.00 | 0.00 |
December | 0.847722E+09 | 0.537734E+09 | 0.659750E+09 | 0.447720E+09 | 0.212030E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.920094E+10 | 0.440631E+10 | 0.714381E+10 | 0.364284E+10 | 0.350097E+10 | 0.00 | 0.00 |
Minimum of Months | 0.606295E+09 | 0.205269E+09 | 0.525168E+09 | 0.186126E+09 | 0.212030E+09 | 0.00 | 0.00 |
Maximum of Months | 0.904918E+09 | 0.540899E+09 | 0.659750E+09 | 0.447720E+09 | 0.369517E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.336553E+09 | 0.534215E+09 | 0.332836E+09 | 0.148349E+09 | 0.184488E+09 | 0.00 | 0.00 |
February | 0.308970E+09 | 0.437584E+09 | 0.327201E+09 | 0.121091E+09 | 0.206111E+09 | 0.00 | 0.00 |
March | 0.451808E+09 | 0.499119E+09 | 0.442504E+09 | 0.159739E+09 | 0.282765E+09 | 0.00 | 0.00 |
April | 0.646404E+09 | 0.365723E+09 | 0.536265E+09 | 0.222103E+09 | 0.314162E+09 | 0.00 | 0.00 |
May | 0.638378E+09 | 0.336942E+09 | 0.547572E+09 | 0.185046E+09 | 0.362526E+09 | 0.00 | 0.00 |
June | 0.681105E+09 | 0.231469E+09 | 0.534661E+09 | 0.191395E+09 | 0.343266E+09 | 0.00 | 0.00 |
July | 0.842673E+09 | 0.198672E+09 | 0.602429E+09 | 0.250339E+09 | 0.352090E+09 | 0.00 | 0.00 |
August | 0.826382E+09 | 0.206421E+09 | 0.576817E+09 | 0.256267E+09 | 0.320550E+09 | 0.00 | 0.00 |
September | 0.565044E+09 | 0.245968E+09 | 0.418462E+09 | 0.155393E+09 | 0.263069E+09 | 0.00 | 0.00 |
October | 0.527285E+09 | 0.287800E+09 | 0.373730E+09 | 0.157887E+09 | 0.215843E+09 | 0.00 | 0.00 |
November | 0.343336E+09 | 0.454508E+09 | 0.328669E+09 | 0.137061E+09 | 0.191609E+09 | 0.00 | 0.00 |
December | 0.322087E+09 | 0.530873E+09 | 0.320322E+09 | 0.149895E+09 | 0.170427E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.649002E+10 | 0.432929E+10 | 0.534147E+10 | 0.213456E+10 | 0.320690E+10 | 0.00 | 0.00 |
Minimum of Months | 0.308970E+09 | 0.198672E+09 | 0.320322E+09 | 0.121091E+09 | 0.170427E+09 | 0.00 | 0.00 |
Maximum of Months | 0.842673E+09 | 0.534215E+09 | 0.602429E+09 | 0.256267E+09 | 0.362526E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.969601E+09 | 0.652560E+09 | 0.728563E+09 | 0.464692E+09 | 0.263871E+09 | 0.00 | 0.00 |
February | 0.663626E+09 | 0.544643E+09 | 0.559975E+09 | 0.279417E+09 | 0.280557E+09 | 0.00 | 0.00 |
March | 0.602257E+09 | 0.639247E+09 | 0.545722E+09 | 0.194123E+09 | 0.351599E+09 | 0.00 | 0.00 |
April | 0.544532E+09 | 0.457586E+09 | 0.487364E+09 | 0.125858E+09 | 0.361506E+09 | 0.00 | 0.00 |
May | 0.440416E+09 | 0.413556E+09 | 0.439744E+09 | 38989048.81 | 0.400754E+09 | 0.00 | 0.00 |
June | 0.469338E+09 | 0.270918E+09 | 0.409559E+09 | 32316737.75 | 0.377242E+09 | 0.00 | 0.00 |
July | 0.554606E+09 | 0.224575E+09 | 0.422961E+09 | 40508848.09 | 0.382452E+09 | 0.00 | 0.00 |
August | 0.619050E+09 | 0.237320E+09 | 0.450074E+09 | 90352972.52 | 0.359721E+09 | 0.00 | 0.00 |
September | 0.713851E+09 | 0.293950E+09 | 0.510578E+09 | 0.184157E+09 | 0.326420E+09 | 0.00 | 0.00 |
October | 0.948668E+09 | 0.348035E+09 | 0.616468E+09 | 0.337062E+09 | 0.279406E+09 | 0.00 | 0.00 |
November | 0.922477E+09 | 0.554402E+09 | 0.690465E+09 | 0.418113E+09 | 0.272352E+09 | 0.00 | 0.00 |
December | 0.103973E+10 | 0.646279E+09 | 0.766322E+09 | 0.516141E+09 | 0.250182E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.848815E+10 | 0.528307E+10 | 0.662780E+10 | 0.272173E+10 | 0.390606E+10 | 0.00 | 0.00 |
Minimum of Months | 0.440416E+09 | 0.224575E+09 | 0.409559E+09 | 32316737.75 | 0.250182E+09 | 0.00 | 0.00 |
Maximum of Months | 0.103973E+10 | 0.652560E+09 | 0.766322E+09 | 0.516141E+09 | 0.400754E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.799381E+09 | 0.550835E+09 | 0.630296E+09 | 0.401891E+09 | 0.228405E+09 | 0.00 | 0.00 |
February | 0.642892E+09 | 0.452740E+09 | 0.546395E+09 | 0.293386E+09 | 0.253008E+09 | 0.00 | 0.00 |
March | 0.677669E+09 | 0.524890E+09 | 0.591890E+09 | 0.271965E+09 | 0.319925E+09 | 0.00 | 0.00 |
April | 0.827831E+09 | 0.388882E+09 | 0.668632E+09 | 0.322730E+09 | 0.345902E+09 | 0.00 | 0.00 |
May | 0.740951E+09 | 0.358090E+09 | 0.625242E+09 | 0.242193E+09 | 0.383049E+09 | 0.00 | 0.00 |
June | 0.792617E+09 | 0.244585E+09 | 0.616959E+09 | 0.257278E+09 | 0.359681E+09 | 0.00 | 0.00 |
July | 0.932348E+09 | 0.208171E+09 | 0.674534E+09 | 0.306866E+09 | 0.367668E+09 | 0.00 | 0.00 |
August | 0.947491E+09 | 0.219426E+09 | 0.676385E+09 | 0.329022E+09 | 0.347363E+09 | 0.00 | 0.00 |
September | 0.883928E+09 | 0.259656E+09 | 0.641513E+09 | 0.334967E+09 | 0.306546E+09 | 0.00 | 0.00 |
October | 0.921133E+09 | 0.306358E+09 | 0.629051E+09 | 0.380515E+09 | 0.248536E+09 | 0.00 | 0.00 |
November | 0.815624E+09 | 0.470271E+09 | 0.636158E+09 | 0.396080E+09 | 0.240078E+09 | 0.00 | 0.00 |
December | 0.851030E+09 | 0.545171E+09 | 0.659625E+09 | 0.441632E+09 | 0.217994E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.983289E+10 | 0.452908E+10 | 0.759668E+10 | 0.397853E+10 | 0.361816E+10 | 0.00 | 0.00 |
Minimum of Months | 0.642892E+09 | 0.208171E+09 | 0.546395E+09 | 0.242193E+09 | 0.217994E+09 | 0.00 | 0.00 |
Maximum of Months | 0.947491E+09 | 0.550835E+09 | 0.676385E+09 | 0.441632E+09 | 0.383049E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.343275E+09 | 0.562298E+09 | 0.320027E+09 | 0.133533E+09 | 0.186494E+09 | 0.00 | 0.00 |
February | 0.356078E+09 | 0.455000E+09 | 0.348265E+09 | 0.132024E+09 | 0.216242E+09 | 0.00 | 0.00 |
March | 0.470344E+09 | 0.521700E+09 | 0.446687E+09 | 0.159861E+09 | 0.286826E+09 | 0.00 | 0.00 |
April | 0.707756E+09 | 0.382815E+09 | 0.577649E+09 | 0.251569E+09 | 0.326080E+09 | 0.00 | 0.00 |
May | 0.719075E+09 | 0.350516E+09 | 0.608037E+09 | 0.231984E+09 | 0.376053E+09 | 0.00 | 0.00 |
June | 0.800979E+09 | 0.238994E+09 | 0.623280E+09 | 0.262552E+09 | 0.360728E+09 | 0.00 | 0.00 |
July | 0.927892E+09 | 0.204542E+09 | 0.667967E+09 | 0.303585E+09 | 0.364382E+09 | 0.00 | 0.00 |
August | 0.869312E+09 | 0.215457E+09 | 0.614122E+09 | 0.281210E+09 | 0.332912E+09 | 0.00 | 0.00 |
September | 0.691056E+09 | 0.254169E+09 | 0.508137E+09 | 0.228648E+09 | 0.279489E+09 | 0.00 | 0.00 |
October | 0.580768E+09 | 0.303568E+09 | 0.405390E+09 | 0.185863E+09 | 0.219527E+09 | 0.00 | 0.00 |
November | 0.395278E+09 | 0.475373E+09 | 0.353383E+09 | 0.154621E+09 | 0.198762E+09 | 0.00 | 0.00 |
December | 0.351183E+09 | 0.558865E+09 | 0.319918E+09 | 0.143562E+09 | 0.176356E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.721300E+10 | 0.452330E+10 | 0.579286E+10 | 0.246901E+10 | 0.332385E+10 | 0.00 | 0.00 |
Minimum of Months | 0.343275E+09 | 0.204542E+09 | 0.319918E+09 | 0.132024E+09 | 0.176356E+09 | 0.00 | 0.00 |
Maximum of Months | 0.927892E+09 | 0.562298E+09 | 0.667967E+09 | 0.303585E+09 | 0.376053E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.752698E+09 | 0.287769E+09 | 0.536043E+09 | 0.393573E+09 | 0.142470E+09 | 0.00 | 0.00 |
February | 0.486942E+09 | 0.237250E+09 | 0.382417E+09 | 0.236654E+09 | 0.145764E+09 | 0.00 | 0.00 |
March | 0.396867E+09 | 0.277826E+09 | 0.337568E+09 | 0.164412E+09 | 0.173156E+09 | 0.00 | 0.00 |
April | 0.302614E+09 | 0.204189E+09 | 0.273094E+09 | 0.105480E+09 | 0.167614E+09 | 0.00 | 0.00 |
May | 0.188408E+09 | 0.187311E+09 | 0.198825E+09 | 23996440.96 | 0.174828E+09 | 0.00 | 0.00 |
June | 0.176453E+09 | 0.126952E+09 | 0.168790E+09 | 9816743.17 | 0.158973E+09 | 0.00 | 0.00 |
July | 0.216515E+09 | 0.106081E+09 | 0.183916E+09 | 19559672.65 | 0.164357E+09 | 0.00 | 0.00 |
August | 0.296149E+09 | 0.111563E+09 | 0.236243E+09 | 73322573.59 | 0.162920E+09 | 0.00 | 0.00 |
September | 0.423409E+09 | 0.135032E+09 | 0.314014E+09 | 0.155950E+09 | 0.158064E+09 | 0.00 | 0.00 |
October | 0.635716E+09 | 0.157979E+09 | 0.425063E+09 | 0.285476E+09 | 0.139587E+09 | 0.00 | 0.00 |
November | 0.696481E+09 | 0.245673E+09 | 0.499748E+09 | 0.354123E+09 | 0.145626E+09 | 0.00 | 0.00 |
December | 0.816404E+09 | 0.285386E+09 | 0.573620E+09 | 0.437148E+09 | 0.136473E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.538866E+10 | 0.236301E+10 | 0.412934E+10 | 0.225951E+10 | 0.186983E+10 | 0.00 | 0.00 |
Minimum of Months | 0.176453E+09 | 0.106081E+09 | 0.168790E+09 | 9816743.17 | 0.136473E+09 | 0.00 | 0.00 |
Maximum of Months | 0.816404E+09 | 0.287769E+09 | 0.573620E+09 | 0.437148E+09 | 0.174828E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.182509E+09 | 0.172330E+10 | 0.386614E+09 | 0.00 | 0.386614E+09 | 0.00 | 0.00 |
February | 0.178734E+09 | 0.146009E+10 | 0.438339E+09 | 0.00 | 0.438339E+09 | 0.00 | 0.00 |
March | 0.315722E+09 | 0.163155E+10 | 0.594757E+09 | 5281.20 | 0.594751E+09 | 0.00 | 0.00 |
April | 0.481716E+09 | 0.118752E+10 | 0.666562E+09 | 5323759.83 | 0.661238E+09 | 0.00 | 0.00 |
May | 0.599710E+09 | 0.106768E+10 | 0.828511E+09 | 43070053.68 | 0.785441E+09 | 0.00 | 0.00 |
June | 0.762896E+09 | 0.750409E+09 | 0.849844E+09 | 83768726.79 | 0.766075E+09 | 0.00 | 0.00 |
July | 0.875325E+09 | 0.659852E+09 | 0.831824E+09 | 70385097.24 | 0.761439E+09 | 0.00 | 0.00 |
August | 0.759456E+09 | 0.717030E+09 | 0.691705E+09 | 15281218.34 | 0.676424E+09 | 0.00 | 0.00 |
September | 0.574192E+09 | 0.843366E+09 | 0.565117E+09 | 109817.17 | 0.565007E+09 | 0.00 | 0.00 |
October | 0.533810E+09 | 0.100028E+10 | 0.463164E+09 | 0.00 | 0.463164E+09 | 0.00 | 0.00 |
November | 0.211561E+09 | 0.149592E+10 | 0.405834E+09 | 0.00 | 0.405834E+09 | 0.00 | 0.00 |
December | 0.165736E+09 | 0.172824E+10 | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.564137E+10 | 0.142652E+11 | 0.708218E+10 | 0.217944E+09 | 0.686423E+10 | 0.00 | 0.00 |
Minimum of Months | 0.165736E+09 | 0.659852E+09 | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.00 | 0.00 |
Maximum of Months | 0.875325E+09 | 0.172824E+10 | 0.849844E+09 | 83768726.79 | 0.785441E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.160791E+09 | 0.179303E+10 | 0.386614E+09 | 0.00 | 0.386614E+09 | 0.00 | 0.00 |
February | 0.156348E+09 | 0.152320E+10 | 0.438339E+09 | 0.00 | 0.438339E+09 | 0.00 | 0.00 |
March | 0.284629E+09 | 0.169664E+10 | 0.594757E+09 | 5281.20 | 0.594751E+09 | 0.00 | 0.00 |
April | 0.443878E+09 | 0.123603E+10 | 0.666562E+09 | 5323759.83 | 0.661238E+09 | 0.00 | 0.00 |
May | 0.552601E+09 | 0.111089E+10 | 0.828511E+09 | 43070053.68 | 0.785441E+09 | 0.00 | 0.00 |
June | 0.713921E+09 | 0.783964E+09 | 0.849844E+09 | 83768726.79 | 0.766075E+09 | 0.00 | 0.00 |
July | 0.826959E+09 | 0.691295E+09 | 0.831824E+09 | 70385097.24 | 0.761439E+09 | 0.00 | 0.00 |
August | 0.717568E+09 | 0.753941E+09 | 0.691705E+09 | 15281218.34 | 0.676424E+09 | 0.00 | 0.00 |
September | 0.538167E+09 | 0.888212E+09 | 0.565117E+09 | 109817.17 | 0.565007E+09 | 0.00 | 0.00 |
October | 0.501852E+09 | 0.105040E+10 | 0.463164E+09 | 0.00 | 0.463164E+09 | 0.00 | 0.00 |
November | 0.187576E+09 | 0.155786E+10 | 0.405834E+09 | 0.00 | 0.405834E+09 | 0.00 | 0.00 |
December | 0.145456E+09 | 0.179874E+10 | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.522974E+10 | 0.148842E+11 | 0.708218E+10 | 0.217944E+09 | 0.686423E+10 | 0.00 | 0.00 |
Minimum of Months | 0.145456E+09 | 0.691295E+09 | 0.359905E+09 | 0.00 | 0.359905E+09 | 0.00 | 0.00 |
Maximum of Months | 0.826959E+09 | 0.179874E+10 | 0.849844E+09 | 83768726.79 | 0.785441E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.120015E+10 | 0.118577E+10 | 0.976448E+09 | 0.565278E+09 | 0.411170E+09 | 0.00 | 0.00 |
February | 0.932860E+09 | 0.104629E+10 | 0.853032E+09 | 0.403725E+09 | 0.449306E+09 | 0.00 | 0.00 |
March | 0.114973E+10 | 0.117873E+10 | 0.103089E+10 | 0.431822E+09 | 0.599065E+09 | 0.00 | 0.00 |
April | 0.148869E+10 | 0.887064E+09 | 0.116433E+10 | 0.515700E+09 | 0.648629E+09 | 0.00 | 0.00 |
May | 0.136282E+10 | 0.839885E+09 | 0.111319E+10 | 0.380578E+09 | 0.732609E+09 | 0.00 | 0.00 |
June | 0.144760E+10 | 0.605440E+09 | 0.106382E+10 | 0.377805E+09 | 0.686015E+09 | 0.00 | 0.00 |
July | 0.182795E+10 | 0.524873E+09 | 0.121234E+10 | 0.504336E+09 | 0.708009E+09 | 0.00 | 0.00 |
August | 0.186520E+10 | 0.543012E+09 | 0.121678E+10 | 0.560730E+09 | 0.656046E+09 | 0.00 | 0.00 |
September | 0.141814E+10 | 0.607587E+09 | 0.970939E+09 | 0.417338E+09 | 0.553601E+09 | 0.00 | 0.00 |
October | 0.149320E+10 | 0.699332E+09 | 0.971691E+09 | 0.510663E+09 | 0.461028E+09 | 0.00 | 0.00 |
November | 0.116173E+10 | 0.103933E+10 | 0.940615E+09 | 0.515786E+09 | 0.424829E+09 | 0.00 | 0.00 |
December | 0.121239E+10 | 0.118332E+10 | 0.980838E+09 | 0.598084E+09 | 0.382753E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.165605E+11 | 0.103406E+11 | 0.124949E+11 | 0.578185E+10 | 0.671306E+10 | 0.00 | 0.00 |
Minimum of Months | 0.932860E+09 | 0.524873E+09 | 0.853032E+09 | 0.377805E+09 | 0.382753E+09 | 0.00 | 0.00 |
Maximum of Months | 0.186520E+10 | 0.118577E+10 | 0.121678E+10 | 0.598084E+09 | 0.732609E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.200118E+10 | 0.119314E+10 | 0.149706E+10 | 0.100186E+10 | 0.495197E+09 | 0.00 | 0.00 |
February | 0.133255E+10 | 0.100451E+10 | 0.112373E+10 | 0.602415E+09 | 0.521313E+09 | 0.00 | 0.00 |
March | 0.116090E+10 | 0.118053E+10 | 0.106318E+10 | 0.418522E+09 | 0.644660E+09 | 0.00 | 0.00 |
April | 0.984186E+09 | 0.867282E+09 | 0.923675E+09 | 0.270331E+09 | 0.653344E+09 | 0.00 | 0.00 |
May | 0.726253E+09 | 0.790610E+09 | 0.790135E+09 | 75848714.34 | 0.714286E+09 | 0.00 | 0.00 |
June | 0.740849E+09 | 0.541312E+09 | 0.720991E+09 | 53705124.71 | 0.667286E+09 | 0.00 | 0.00 |
July | 0.877014E+09 | 0.471995E+09 | 0.753320E+09 | 73918335.13 | 0.679402E+09 | 0.00 | 0.00 |
August | 0.104591E+10 | 0.504765E+09 | 0.838486E+09 | 0.191885E+09 | 0.646601E+09 | 0.00 | 0.00 |
September | 0.132135E+10 | 0.586313E+09 | 0.993061E+09 | 0.397016E+09 | 0.596045E+09 | 0.00 | 0.00 |
October | 0.183816E+10 | 0.687311E+09 | 0.124079E+10 | 0.726695E+09 | 0.514099E+09 | 0.00 | 0.00 |
November | 0.187866E+10 | 0.102540E+10 | 0.141126E+10 | 0.901438E+09 | 0.509818E+09 | 0.00 | 0.00 |
December | 0.215464E+10 | 0.118140E+10 | 0.158356E+10 | 0.111278E+10 | 0.470775E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.160616E+11 | 0.100346E+11 | 0.129392E+11 | 0.582642E+10 | 0.711283E+10 | 0.00 | 0.00 |
Minimum of Months | 0.726253E+09 | 0.471995E+09 | 0.720991E+09 | 53705124.71 | 0.470775E+09 | 0.00 | 0.00 |
Maximum of Months | 0.215464E+10 | 0.119314E+10 | 0.158356E+10 | 0.111278E+10 | 0.714286E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 13.22 | 9.60 | 5.99 | 2.23 | 0.81 | 45.19 | 208.20 | 0.00 |
February | 13.28 | 10.19 | 7.03 | 3.12 | 2.95 | 66.07 | 175.60 | 0.04 |
March | 12.64 | 10.60 | 8.97 | 2.93 | 3.55 | 84.90 | 179.28 | 0.03 |
April | 15.30 | 12.61 | 10.61 | 2.62 | 4.75 | 81.20 | 282.81 | 0.02 |
May | 15.56 | 12.64 | 10.56 | 2.92 | 6.16 | 105.80 | 234.18 | 0.01 |
June | 17.67 | 14.80 | 13.02 | 2.53 | 9.02 | 98.05 | 261.27 | 0.00 |
July | 19.43 | 16.75 | 15.28 | 2.35 | 9.62 | 86.54 | 312.15 | 0.00 |
August | 19.66 | 17.23 | 15.95 | 2.55 | 9.61 | 74.58 | 307.55 | 0.00 |
September | 18.47 | 15.49 | 13.65 | 2.19 | 8.98 | 70.75 | 240.05 | 0.00 |
October | 18.77 | 13.71 | 9.60 | 2.71 | 7.73 | 53.88 | 216.36 | 0.00 |
November | 14.32 | 10.42 | 6.22 | 2.47 | 2.40 | 50.75 | 207.87 | 0.01 |
December | 13.59 | 8.80 | 3.19 | 2.50 | 0.04 | 39.49 | 221.83 | 0.00 |
Annual Sum or Average | 16.01 | 12.75 | 10.02 | 2.59 | 5.48 | 71.44 | 237.65 | 0.01 |
Minimum of Months | 12.64 | 8.80 | 3.19 | 2.19 | 0.04 | 39.49 | 175.60 | 0.00 |
Maximum of Months | 19.66 | 17.23 | 15.95 | 3.12 | 9.62 | 105.80 | 312.15 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 26.00 | 13-JAN-13:00 | 15.44 | 8.00 | 3.10 | 11.84 | 120.00 | 725.00 |
February | 26.00 | 01-FEB-11:00 | 14.65 | 6.00 | 4.10 | 10.11 | 166.00 | 715.50 |
March | 24.00 | 11-MAR-10:00 | 13.80 | 6.00 | 2.60 | 8.15 | 120.00 | 907.00 |
April | 27.00 | 26-APR-12:00 | 17.11 | 11.00 | 4.10 | 12.22 | 159.00 | 884.00 |
May | 24.00 | 03-MAY-11:00 | 15.03 | 9.00 | 4.10 | 12.98 | 187.00 | 842.50 |
June | 25.00 | 29-JUN-10:00 | 19.58 | 17.00 | 4.60 | 11.65 | 177.50 | 829.00 |
July | 28.00 | 19-JUL-10:00 | 20.48 | 17.00 | 3.60 | 14.65 | 173.00 | 813.00 |
August | 28.00 | 14-AUG-10:00 | 21.18 | 18.00 | 3.60 | 14.84 | 148.00 | 840.00 |
September | 36.00 | 29-SEP-10:00 | 17.88 | 5.00 | 3.60 | 19.35 | 159.50 | 790.00 |
October | 37.00 | 16-OCT-10:00 | 17.83 | 4.00 | 5.70 | 20.05 | 122.00 | 871.50 |
November | 27.00 | 19-NOV-12:00 | 14.94 | 6.00 | 4.10 | 11.07 | 128.50 | 796.00 |
December | 26.00 | 05-DEC-09:00 | 13.06 | 1.00 | 3.60 | 8.94 | 75.50 | 857.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.00 | 13.06 | 1.00 | 2.60 | 8.15 | 75.50 | 715.50 | |
Maximum of Months | 37.00 | 21.18 | 18.00 | 5.70 | 20.05 | 187.00 | 907.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.00 | 08-JAN-06:00 | -0.2 | -2.0 | 3.10 | -15.5 | 11.50 | 193.50 |
February | 5.00 | 04-FEB-05:00 | 0.20 | -8.0 | 4.10 | -10.9 | 0.00 | 0.00 |
March | 4.00 | 07-MAR-04:00 | 3.53 | 3.00 | 0.00 | -11.4 | 0.00 | 0.00 |
April | 7.00 | 01-APR-05:00 | 4.32 | 1.00 | 4.10 | -9.0 | 23.50 | 211.00 |
May | 8.00 | 14-MAY-03:00 | 7.45 | 7.00 | 1.50 | -6.6 | 0.00 | 0.00 |
June | 11.00 | 13-JUN-03:00 | 9.85 | 9.00 | 2.10 | -3.4 | 0.00 | 0.00 |
July | 13.00 | 06-JUL-00:00 | 13.00 | 13.00 | 0.00 | -0.6 | 0.00 | 0.00 |
August | 14.00 | 24-AUG-01:00 | 14.00 | 14.00 | 0.00 | 0.51 | 0.00 | 0.00 |
September | 11.00 | 20-SEP-02:00 | 9.85 | 9.00 | 1.50 | -3.4 | 0.00 | 0.00 |
October | 9.00 | 12-OCT-04:00 | 6.55 | 4.00 | 3.10 | -6.4 | 0.00 | 0.00 |
November | 7.00 | 05-NOV-01:00 | 5.53 | 4.00 | 3.10 | -8.3 | 0.00 | 0.00 |
December | 5.00 | 03-DEC-00:00 | 5.00 | 5.00 | 2.10 | -0.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.00 | -0.2 | -8.0 | 0.00 | -15.5 | 0.00 | 0.00 | |
Maximum of Months | 14.00 | 14.00 | 14.00 | 4.10 | 0.51 | 23.50 | 211.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 17.02 | 17-JAN-11:00 | 24.00 | 13.00 | 3.10 | 12.79 | 223.50 | 9.00 |
February | 16.80 | 11-FEB-13:00 | 18.00 | 16.20 | 1.10 | 15.02 | 241.00 | 12.50 |
March | 17.40 | 22-MAR-12:00 | 22.00 | 15.00 | 3.10 | 8.35 | 145.50 | 876.00 |
April | 18.31 | 26-APR-10:00 | 26.00 | 14.00 | 4.10 | 12.03 | 141.50 | 915.50 |
May | 16.69 | 05-MAY-14:00 | 18.00 | 16.00 | 5.10 | 8.74 | 303.50 | 269.00 |
June | 19.58 | 29-JUN-10:00 | 25.00 | 17.00 | 4.60 | 11.65 | 177.50 | 829.00 |
July | 21.18 | 19-JUL-11:00 | 28.00 | 18.00 | 4.60 | 14.84 | 182.50 | 808.00 |
August | 21.18 | 18-AUG-11:00 | 28.00 | 18.00 | 3.60 | 17.21 | 244.00 | 667.50 |
September | 21.84 | 22-SEP-11:00 | 26.00 | 20.00 | 2.60 | 20.05 | 284.00 | 21.00 |
October | 21.08 | 01-OCT-11:00 | 26.00 | 19.00 | 3.60 | 13.16 | 102.00 | 899.50 |
November | 16.52 | 10-NOV-12:00 | 21.00 | 14.00 | 5.10 | 7.15 | 131.00 | 808.50 |
December | 15.63 | 07-DEC-12:00 | 20.00 | 13.00 | 5.10 | 5.94 | 89.00 | 868.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.63 | 18.00 | 13.00 | 1.10 | 5.94 | 89.00 | 9.00 | |
Maximum of Months | 21.84 | 28.00 | 20.00 | 5.10 | 20.05 | 303.50 | 915.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 17-JAN-12:00 | 22.00 | 16.84 | 2.10 | 11.65 | 241.50 | 67.50 |
February | 16.20 | 11-FEB-13:00 | 18.00 | 16.80 | 1.10 | 15.02 | 241.00 | 12.50 |
March | 15.00 | 23-MAR-15:20 | 21.67 | 17.33 | 3.77 | 8.01 | 112.00 | 809.83 |
April | 15.00 | 26-APR-21:19 | 16.00 | 15.39 | 2.23 | 6.02 | 0.00 | 0.00 |
May | 16.00 | 05-MAY-14:00 | 18.00 | 16.69 | 5.10 | 8.74 | 303.50 | 269.00 |
June | 17.00 | 28-JUN-08:00 | 19.00 | 17.66 | 1.50 | 16.12 | 285.00 | 428.50 |
July | 18.00 | 18-JUL-10:00 | 26.00 | 20.46 | 4.60 | 12.79 | 169.00 | 819.00 |
August | 18.10 | 14-AUG-09:00 | 26.90 | 20.91 | 3.40 | 13.73 | 139.00 | 817.00 |
September | 20.00 | 22-SEP-09:00 | 22.00 | 20.55 | 1.50 | 16.30 | 296.00 | 18.00 |
October | 19.00 | 01-OCT-07:10 | 19.17 | 19.06 | 0.25 | 16.82 | 53.33 | 0.00 |
November | 15.00 | 10-NOV-17:19 | 16.67 | 15.62 | 2.77 | 3.34 | 0.00 | 0.00 |
December | 13.00 | 07-DEC-12:00 | 20.00 | 15.63 | 5.10 | 5.94 | 89.00 | 868.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 13.00 | 16.00 | 15.39 | 0.25 | 3.34 | 0.00 | 0.00 | |
Maximum of Months | 20.00 | 26.90 | 20.91 | 5.10 | 16.82 | 303.50 | 868.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 17.43 | 27.46 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 17.38 | 30.87 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 17.83 | 38.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 18.69 | 55.75 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 19.73 | 55.13 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 20.65 | 58.21 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 21.22 | 63.49 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 21.28 | 59.02 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 20.81 | 46.26 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 19.94 | 34.64 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 18.91 | 29.25 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 17.99 | 26.27 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.33 | 43.77 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 17.38 | 26.27 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 21.28 | 63.49 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.304305E+11 | -.607864E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.153069E+10 | 59.15 | 0.00 | 0.00 |
February | 0.275581E+11 | -.549574E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -.139487E+10 | 59.12 | 0.00 | 0.00 |
March | 0.299027E+11 | -.602679E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.155799E+10 | 59.21 | 0.00 | 0.00 |
April | 0.275989E+11 | -.570752E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.151546E+10 | 59.23 | 0.00 | 0.00 |
May | 0.269362E+11 | -.575017E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.157235E+10 | 59.31 | 0.00 | 0.00 |
June | 0.247061E+11 | -.543711E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.153493E+10 | 59.39 | 0.00 | 0.00 |
July | 0.245493E+11 | -.552789E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.158192E+10 | 59.36 | 0.00 | 0.00 |
August | 0.245147E+11 | -.552480E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.158005E+10 | 59.36 | 0.00 | 0.00 |
September | 0.244008E+11 | -.541112E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.151184E+10 | 59.39 | 0.00 | 0.00 |
October | 0.265412E+11 | -.571607E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.154700E+10 | 59.31 | 0.00 | 0.00 |
November | 0.272278E+11 | -.567721E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.147366E+10 | 59.30 | 0.00 | 0.00 |
December | 0.295560E+11 | -.599746E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.152964E+10 | 59.20 | 0.00 | 0.00 |
Annual Sum or Average | 0.323922E+12 | -.683505E+12 | 8760.00 | -.183304E+11 | 59.28 | |||||
Minimum of Months | 0.244008E+11 | -.607864E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -.158192E+10 | 59.12 | 0.00 | 0.00 |
Maximum of Months | 0.304305E+11 | -.541112E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.139487E+10 | 59.39 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: SHW BOOSTER WATER HEATER
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.770551E+10 | -.754278E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162724279.6 | 81.21 | 0.00 | 0.00 |
February | 0.696261E+10 | -.681597E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -146638355.0 | 81.21 | 0.00 | 0.00 |
March | 0.770529E+10 | -.754280E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162486609.0 | 81.21 | 0.00 | 0.00 |
April | 0.746559E+10 | -.730859E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -157006274.1 | 81.21 | 0.00 | 0.00 |
May | 0.770509E+10 | -.754280E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162293791.7 | 81.21 | 0.00 | 0.00 |
June | 0.745776E+10 | -.730052E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -157239178.0 | 81.21 | 0.00 | 0.00 |
July | 0.771348E+10 | -.755084E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162638072.2 | 81.21 | 0.00 | 0.00 |
August | 0.770546E+10 | -.754280E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162659969.2 | 81.21 | 0.00 | 0.00 |
September | 0.746594E+10 | -.730858E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -157364620.3 | 81.21 | 0.00 | 0.00 |
October | 0.770534E+10 | -.754277E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162571478.2 | 81.21 | 0.00 | 0.00 |
November | 0.744954E+10 | -.729243E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -157116080.6 | 81.21 | 0.00 | 0.00 |
December | 0.771349E+10 | -.755085E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -162647469.6 | 81.21 | 0.00 | 0.00 |
Annual Sum or Average | 0.907551E+11 | -.888417E+11 | 8760.00 | -.191339E+10 | 81.21 | |||||
Minimum of Months | 0.696261E+10 | -.755085E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -162724279.6 | 81.21 | 0.00 | 0.00 |
Maximum of Months | 0.771349E+10 | -.681597E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -146638355.0 | 81.21 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWH LAUNDRY
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.776144E+11 | -.763241E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.129030E+10 | 65.32 | 0.00 | 0.00 |
February | 0.701118E+11 | -.689381E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -.117378E+10 | 65.28 | 0.00 | 0.00 |
March | 0.775532E+11 | -.762429E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.131024E+10 | 65.40 | 0.00 | 0.00 |
April | 0.749374E+11 | -.736556E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.128176E+10 | 65.70 | 0.00 | 0.00 |
May | 0.772848E+11 | -.759481E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.133670E+10 | 66.02 | 0.00 | 0.00 |
June | 0.746625E+11 | -.733532E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.130926E+10 | 66.32 | 0.00 | 0.00 |
July | 0.770683E+11 | -.757120E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.135623E+10 | 66.50 | 0.00 | 0.00 |
August | 0.770590E+11 | -.757036E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.135541E+10 | 66.52 | 0.00 | 0.00 |
September | 0.746377E+11 | -.733436E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.129410E+10 | 66.37 | 0.00 | 0.00 |
October | 0.772502E+11 | -.759299E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.132029E+10 | 66.09 | 0.00 | 0.00 |
November | 0.749002E+11 | -.736479E+11 | 0.00 | 0.00 | 720.00 | 0.00 | -.125222E+10 | 65.79 | 0.00 | 0.00 |
December | 0.775333E+11 | -.762409E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.129239E+10 | 65.47 | 0.00 | 0.00 |
Annual Sum or Average | 0.910613E+12 | -.895040E+12 | 8760.00 | -.155727E+11 | 65.90 | |||||
Minimum of Months | 0.701118E+11 | -.763241E+11 | 0.00 | 0.00 | 672.00 | 0.00 | -.135623E+10 | 65.28 | 0.00 | 0.00 |
Maximum of Months | 0.776144E+11 | -.689381E+11 | 0.00 | 0.00 | 744.00 | 0.00 | -.117378E+10 | 66.52 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: LOBBY_FLR_1_DAYLCTRL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 293.33 | 0.93 | 0.93 | 01-JAN-07:19 | 6394.86 | 37.25 | 284.83 | 280.00 | 922.12 | 26.83 | 187.67 | 262.67 |
February | 279.67 | 0.93 | 0.93 | 01-FEB-07:19 | 4448.16 | 31.95 | 218.17 | 274.67 | 609.37 | 23.51 | 165.00 | 242.83 |
March | 338.17 | 0.93 | 0.93 | 01-MAR-06:49 | 1168.01 | 19.63 | 14.00 | 320.17 | 436.09 | 20.91 | 151.17 | 258.00 |
April | 358.33 | 0.93 | 0.93 | 01-APR-06:30 | 803.53 | 19.13 | 0.00 | 332.33 | 339.47 | 20.91 | 140.33 | 259.67 |
May | 393.83 | 0.94 | 0.93 | 01-MAY-06:10 | 729.93 | 18.63 | 0.00 | 363.33 | 297.73 | 20.38 | 111.83 | 255.00 |
June | 381.00 | 0.94 | 0.93 | 01-JUN-06:10 | 631.28 | 18.43 | 0.00 | 354.33 | 266.14 | 20.20 | 61.50 | 229.17 |
July | 408.67 | 0.94 | 0.93 | 01-JUL-05:00 | 621.88 | 18.55 | 0.00 | 363.33 | 271.69 | 20.34 | 88.00 | 243.33 |
August | 390.67 | 0.94 | 0.93 | 01-AUG-06:49 | 676.36 | 18.81 | 0.00 | 353.33 | 295.01 | 20.59 | 135.67 | 263.83 |
September | 328.83 | 0.93 | 0.93 | 01-SEP-06:40 | 908.59 | 19.12 | 0.00 | 308.00 | 378.80 | 20.92 | 142.00 | 252.83 |
October | 296.17 | 0.93 | 0.93 | 01-OCT-09:39 | 3068.60 | 26.98 | 136.33 | 304.17 | 448.33 | 21.43 | 100.50 | 248.33 |
November | 300.00 | 0.93 | 0.93 | 01-NOV-06:40 | 6225.82 | 37.09 | 294.67 | 280.17 | 808.59 | 26.41 | 200.00 | 266.83 |
December | 297.00 | 0.93 | 0.93 | 01-DEC-07:10 | 6257.69 | 37.67 | 289.17 | 280.67 | 1130.08 | 28.38 | 184.67 | 265.50 |
Annual Sum or Average | 4065.67 | 0.93 | 2406.24 | 24.41 | 1237.17 | 3814.50 | 489.59 | 22.30 | 1668.33 | 3048.00 | ||
Minimum of Months | 279.67 | 0.93 | 0.93 | 621.88 | 18.43 | 0.00 | 274.67 | 266.14 | 20.20 | 61.50 | 229.17 | |
Maximum of Months | 408.67 | 0.94 | 0.93 | 6394.86 | 37.67 | 294.67 | 363.33 | 1130.08 | 28.38 | 200.00 | 266.83 |
Report: DaylightingReportMonthly
For: CAFE_FLR_1_DAYLCTRL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 293.33 | 0.62 | 0.61 | 01-JAN-07:19 | 6769.30 | 37.33 | 285.00 | 284.67 | 1298.31 | 26.56 | 172.00 | 272.50 |
February | 279.67 | 0.62 | 0.61 | 01-FEB-07:10 | 4745.46 | 32.06 | 218.50 | 281.50 | 906.25 | 23.59 | 165.83 | 262.00 |
March | 338.17 | 0.63 | 0.61 | 01-MAR-06:49 | 1397.32 | 20.12 | 29.00 | 328.67 | 664.52 | 21.23 | 182.67 | 298.67 |
April | 358.33 | 0.63 | 0.61 | 01-APR-06:19 | 988.55 | 19.75 | 12.33 | 345.67 | 524.02 | 21.31 | 192.33 | 313.33 |
May | 393.83 | 0.63 | 0.61 | 01-MAY-05:00 | 860.79 | 19.47 | 0.00 | 378.50 | 428.12 | 21.00 | 201.50 | 339.50 |
June | 381.00 | 0.63 | 0.61 | 01-JUN-05:49 | 749.08 | 19.32 | 0.00 | 367.83 | 383.53 | 20.86 | 187.50 | 329.67 |
July | 408.67 | 0.63 | 0.61 | 01-JUL-05:40 | 746.35 | 19.39 | 0.00 | 377.17 | 395.77 | 20.95 | 237.17 | 344.50 |
August | 390.67 | 0.63 | 0.61 | 01-AUG-06:40 | 830.97 | 19.52 | 0.17 | 367.17 | 449.22 | 21.08 | 204.50 | 333.83 |
September | 328.83 | 0.63 | 0.61 | 01-SEP-06:19 | 1129.71 | 19.61 | 17.00 | 321.33 | 599.38 | 21.22 | 152.00 | 289.67 |
October | 296.17 | 0.62 | 0.61 | 01-OCT-09:39 | 3372.13 | 27.04 | 137.00 | 315.83 | 749.86 | 21.41 | 101.33 | 281.33 |
November | 300.00 | 0.63 | 0.61 | 01-NOV-06:40 | 6578.20 | 37.14 | 294.83 | 285.83 | 1158.35 | 26.20 | 189.17 | 275.17 |
December | 297.00 | 0.63 | 0.61 | 01-DEC-06:00 | 6647.42 | 37.75 | 289.17 | 286.50 | 1519.10 | 28.06 | 169.67 | 275.67 |
Annual Sum or Average | 4065.67 | 0.63 | 2634.64 | 24.89 | 1283.00 | 3940.67 | 717.37 | 22.56 | 2155.67 | 3615.83 | ||
Minimum of Months | 279.67 | 0.62 | 0.61 | 746.35 | 19.32 | 0.00 | 281.50 | 383.53 | 20.86 | 101.33 | 262.00 | |
Maximum of Months | 408.67 | 0.63 | 0.61 | 6769.30 | 37.75 | 294.83 | 378.50 | 1519.10 | 28.06 | 237.17 | 344.50 |
Report: DaylightingReportMonthly
For: DINING_FLR_6_DAYLCTRL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 293.33 | 0.82 | 0.80 | 01-JAN-08:30 | 300.62 | 14.29 | 0.00 | 238.33 | 155.64 | 17.86 | 0.00 | 33.67 |
February | 279.67 | 0.82 | 0.80 | 01-FEB-08:09 | 375.96 | 15.16 | 0.00 | 255.67 | 180.40 | 18.50 | 0.00 | 88.50 |
March | 338.17 | 0.82 | 0.80 | 01-MAR-07:30 | 450.22 | 15.74 | 0.00 | 313.00 | 206.87 | 18.95 | 0.00 | 176.50 |
April | 358.33 | 0.81 | 0.80 | 01-APR-06:30 | 474.39 | 16.68 | 0.00 | 343.00 | 232.26 | 19.95 | 13.67 | 268.00 |
May | 393.83 | 0.81 | 0.80 | 01-MAY-05:00 | 637.80 | 17.63 | 12.50 | 386.50 | 287.15 | 20.84 | 59.33 | 344.83 |
June | 381.00 | 0.81 | 0.80 | 01-JUN-05:49 | 675.46 | 19.66 | 58.83 | 380.67 | 312.53 | 22.06 | 107.50 | 340.00 |
July | 408.67 | 0.81 | 0.80 | 01-JUL-05:19 | 614.15 | 18.92 | 44.67 | 390.00 | 270.78 | 20.53 | 85.50 | 357.50 |
August | 390.67 | 0.81 | 0.80 | 01-AUG-06:40 | 486.60 | 16.76 | 0.00 | 370.17 | 233.96 | 20.05 | 32.83 | 294.83 |
September | 328.83 | 0.81 | 0.80 | 01-SEP-06:30 | 417.96 | 16.02 | 0.00 | 310.67 | 207.51 | 19.32 | 0.00 | 181.00 |
October | 296.17 | 0.83 | 0.80 | 01-OCT-09:39 | 311.48 | 14.64 | 0.00 | 252.33 | 158.17 | 18.10 | 0.00 | 55.83 |
November | 300.00 | 0.83 | 0.80 | 01-NOV-07:10 | 308.34 | 14.09 | 0.00 | 243.67 | 157.19 | 17.55 | 0.00 | 51.00 |
December | 297.00 | 0.83 | 0.80 | 01-DEC-07:40 | 271.14 | 13.75 | 0.00 | 229.50 | 144.38 | 17.39 | 0.00 | 18.67 |
Annual Sum or Average | 4065.67 | 0.82 | 459.43 | 16.32 | 116.00 | 3713.50 | 218.57 | 19.42 | 298.83 | 2210.33 | ||
Minimum of Months | 279.67 | 0.81 | 0.80 | 271.14 | 13.75 | 0.00 | 229.50 | 144.38 | 17.39 | 0.00 | 18.67 | |
Maximum of Months | 408.67 | 0.83 | 0.80 | 675.46 | 19.66 | 58.83 | 390.00 | 312.53 | 22.06 | 107.50 | 357.50 |
Report: DaylightingReportMonthly
For: BANQUET_FLR_6_DAYLCTRL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 293.33 | 0.82 | 0.80 | 01-JAN-08:30 | 300.62 | 14.29 | 0.00 | 238.33 | 155.64 | 17.86 | 0.00 | 33.67 |
February | 279.67 | 0.82 | 0.80 | 01-FEB-08:09 | 375.96 | 15.16 | 0.00 | 255.67 | 180.40 | 18.50 | 0.00 | 88.50 |
March | 338.17 | 0.82 | 0.80 | 01-MAR-07:30 | 450.22 | 15.74 | 0.00 | 313.00 | 206.87 | 18.95 | 0.00 | 176.50 |
April | 358.33 | 0.81 | 0.80 | 01-APR-06:30 | 474.39 | 16.68 | 0.00 | 343.00 | 232.26 | 19.95 | 13.67 | 268.00 |
May | 393.83 | 0.81 | 0.80 | 01-MAY-05:00 | 637.80 | 17.63 | 12.50 | 386.50 | 287.15 | 20.84 | 59.33 | 344.83 |
June | 381.00 | 0.81 | 0.80 | 01-JUN-05:49 | 675.46 | 19.66 | 58.83 | 380.67 | 312.53 | 22.06 | 107.50 | 340.00 |
July | 408.67 | 0.81 | 0.80 | 01-JUL-05:19 | 614.15 | 18.92 | 44.67 | 390.00 | 270.78 | 20.53 | 85.50 | 357.50 |
August | 390.67 | 0.81 | 0.80 | 01-AUG-06:40 | 486.60 | 16.76 | 0.00 | 370.17 | 233.96 | 20.05 | 32.83 | 294.83 |
September | 328.83 | 0.81 | 0.80 | 01-SEP-06:30 | 417.96 | 16.02 | 0.00 | 310.67 | 207.51 | 19.32 | 0.00 | 181.00 |
October | 296.17 | 0.83 | 0.80 | 01-OCT-09:39 | 311.48 | 14.64 | 0.00 | 252.33 | 158.17 | 18.10 | 0.00 | 55.83 |
November | 300.00 | 0.83 | 0.80 | 01-NOV-07:10 | 308.34 | 14.09 | 0.00 | 243.67 | 157.19 | 17.55 | 0.00 | 51.00 |
December | 297.00 | 0.83 | 0.80 | 01-DEC-07:40 | 271.14 | 13.75 | 0.00 | 229.50 | 144.38 | 17.39 | 0.00 | 18.67 |
Annual Sum or Average | 4065.67 | 0.82 | 459.43 | 16.32 | 116.00 | 3713.50 | 218.57 | 19.42 | 298.83 | 2210.33 | ||
Minimum of Months | 279.67 | 0.81 | 0.80 | 271.14 | 13.75 | 0.00 | 229.50 | 144.38 | 17.39 | 0.00 | 18.67 | |
Maximum of Months | 408.67 | 0.83 | 0.80 | 675.46 | 19.66 | 58.83 | 390.00 | 312.53 | 22.06 | 107.50 | 357.50 |
Report: CoilReportMonthly
For: BASEMENT VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 18894489.42 | 1175.18 | 30-APR-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 47248496.30 | 1212.25 | 04-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.812724E+09 | 3432.02 | 25-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.180717E+09 | 2331.42 | 02-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 61312322.87 | 1489.46 | 20-AUG-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.112090E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.812724E+09 | 3432.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: RETAIL_1_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.724700E+09 | 2059.31 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.644976E+09 | 1663.58 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.105760E+10 | 1943.44 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.505176E+09 | 1573.58 | 01-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.765909E+09 | 1278.76 | 14-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.533710E+09 | 743.09 | 11-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.310065E+09 | 492.07 | 09-JUL-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.197282E+09 | 582.99 | 06-AUG-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.229624E+09 | 636.36 | 18-SEP-10:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.209682E+09 | 726.23 | 25-OCT-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.303140E+09 | 1249.93 | 05-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.542680E+09 | 1746.39 | 13-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.602455E+10 | |||||||
Minimum of Months | 0.197282E+09 | 492.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.105760E+10 | 2059.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: RETAIL_2_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 26264145.49 | 819.94 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 9250450.27 | 271.73 | 13-FEB-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 28358276.58 | 558.62 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 3556418.21 | 185.72 | 01-APR-10:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 5320558.64 | 143.79 | 15-MAY-11:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 5334846.99 | 145.31 | 11-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 31583.32 | 7.35 | 03-JUL-13:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 388413.77 | 66.16 | 22-SEP-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 1617937.45 | 131.65 | 06-OCT-13:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 15081.75 | 21.09 | 24-DEC-04:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 80137712.47 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 28358276.58 | 819.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: MECH_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.288400E+09 | 1174.29 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 84157590.00 | 486.10 | 09-FEB-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.268126E+09 | 1108.28 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 62701030.26 | 550.49 | 01-APR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 32267268.20 | 227.27 | 15-MAY-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 3403003.10 | 98.83 | 01-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 3830100.90 | 104.97 | 04-SEP-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 2206559.65 | 117.17 | 09-OCT-16:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 9798570.81 | 213.87 | 05-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.130615E+09 | 779.11 | 23-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.885505E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.288400E+09 | 1174.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: STORAGE_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.226518E+09 | 672.62 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 94674460.95 | 337.65 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.228072E+09 | 634.77 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 51311423.47 | 373.98 | 01-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 33545339.15 | 174.11 | 14-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 3786005.84 | 74.62 | 01-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 2481162.85 | 60.02 | 03-SEP-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 1271487.58 | 67.44 | 09-OCT-16:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 15631096.08 | 218.37 | 05-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.117758E+09 | 479.77 | 24-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.775048E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.228072E+09 | 672.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: LAUNDRY_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.316156E+10 | 8234.59 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.165287E+10 | 7613.28 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.243167E+10 | 7774.57 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.236390E+10 | 6000.12 | 01-APR-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.267249E+10 | 5182.12 | 27-MAY-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.363392E+10 | 6422.40 | 26-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.446575E+10 | 6422.33 | 29-JUL-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.463711E+10 | 6713.06 | 19-AUG-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.402019E+10 | 7266.34 | 30-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.387263E+10 | 7264.73 | 05-OCT-03:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.198942E+10 | 7302.30 | 08-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.294196E+10 | 7619.49 | 24-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.378435E+11 | |||||||
Minimum of Months | 0.165287E+10 | 5182.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.463711E+10 | 8234.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CAFE_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.261659E+09 | 5739.08 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.231177E+09 | 3235.91 | 12-FEB-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.484008E+09 | 5166.90 | 30-MAR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.101895E+09 | 2169.45 | 17-APR-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.516675E+09 | 2331.23 | 09-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.510956E+09 | 2413.25 | 11-JUN-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.260845E+09 | 1628.91 | 17-JUL-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 51791033.24 | 1321.22 | 14-AUG-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 76875736.27 | 1880.18 | 21-SEP-11:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 98030361.12 | 1779.31 | 24-OCT-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 21906808.80 | 1838.09 | 11-NOV-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 65255194.67 | 2128.12 | 13-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.268108E+10 | |||||||
Minimum of Months | 21906808.80 | 1321.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.516675E+09 | 5739.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: LOBBY_FLR_1 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.144357E+09 | 10868.98 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 82181406.44 | 3890.24 | 12-FEB-13:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.145962E+09 | 8765.46 | 29-MAR-11:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 16070514.90 | 2116.08 | 17-APR-12:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.136461E+09 | 3068.45 | 28-MAY-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.112892E+09 | 2566.46 | 11-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 61139901.67 | 1951.80 | 04-JUL-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 8204745.74 | 927.23 | 21-SEP-11:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 13727677.48 | 1778.28 | 06-OCT-13:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 44147.28 | 73.58 | 06-DEC-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.721040E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.145962E+09 | 10868.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_3 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.704332E+09 | 4005.54 | 01-JAN-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.520326E+09 | 4048.87 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.770365E+09 | 4125.48 | 29-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.148642E+09 | 2906.45 | 09-APR-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.136667E+09 | 2536.41 | 04-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 19718464.78 | 2330.75 | 22-JUN-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3367051.15 | 2537.86 | 23-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4308477.67 | 2421.35 | 31-AUG-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 7771242.68 | 2385.36 | 13-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 64772997.48 | 3301.54 | 14-OCT-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.310755E+09 | 2628.14 | 19-NOV-09:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.598743E+09 | 3998.59 | 12-DEC-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.328977E+10 | |||||||
Minimum of Months | 3367051.15 | 2330.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.770365E+09 | 4125.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_2_FLR_3 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.127148E+10 | 4071.35 | 12-JAN-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.787484E+09 | 4039.52 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.992589E+09 | 4107.14 | 29-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.203283E+09 | 3535.98 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.141146E+09 | 2488.91 | 04-MAY-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 19053643.34 | 2173.76 | 04-JUN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3098812.84 | 2520.53 | 23-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4358575.84 | 2223.04 | 30-AUG-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 13600348.54 | 2182.82 | 30-SEP-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.126740E+09 | 3951.75 | 30-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.604476E+09 | 3959.65 | 05-NOV-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.112349E+10 | 4045.13 | 13-DEC-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.529080E+10 | |||||||
Minimum of Months | 3098812.84 | 2173.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.127148E+10 | 4107.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 27443653.25 | 3435.76 | 30-MAR-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 27443653.25 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 27443653.25 | 3435.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.320690E+10 | 23014.44 | 12-JAN-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.998982E+09 | 22598.76 | 14-FEB-16:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.194323E+10 | 23207.27 | 29-MAR-15:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.219262E+09 | 22583.02 | 19-APR-15:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.124898E+09 | 20232.07 | 12-MAY-15:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 58989468.54 | 19519.40 | 04-JUN-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 43996966.93 | 16850.09 | 31-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 53079217.61 | 18751.80 | 14-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 55929429.86 | 18519.29 | 23-SEP-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.108678E+09 | 22585.01 | 23-OCT-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.977236E+09 | 22587.42 | 12-NOV-16:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.250351E+10 | 22827.01 | 15-DEC-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.102947E+11 | |||||||
Minimum of Months | 43996966.93 | 16850.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.320690E+10 | 23207.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_5_FLR_3 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.695032E+09 | 3863.68 | 02-JAN-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.591274E+09 | 3902.47 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.819913E+09 | 3975.35 | 29-MAR-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.194315E+09 | 2564.55 | 22-APR-15:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.203823E+09 | 2478.75 | 26-MAY-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 41919105.90 | 2162.42 | 07-JUN-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3602343.05 | 2050.83 | 09-JUL-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 2877554.34 | 1769.89 | 04-AUG-18:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 20834322.09 | 2273.41 | 19-SEP-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 77416923.01 | 2584.86 | 23-OCT-15:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.360922E+09 | 3140.68 | 22-NOV-16:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.624607E+09 | 3870.79 | 12-DEC-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.363654E+10 | |||||||
Minimum of Months | 2877554.34 | 1769.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.819913E+09 | 3975.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_6_FLR_3 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.122951E+10 | 3926.38 | 02-JAN-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.872598E+09 | 3905.89 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.104348E+10 | 3976.10 | 29-MAR-18:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.268228E+09 | 2632.53 | 15-APR-15:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.215302E+09 | 2271.63 | 13-MAY-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 41881396.34 | 2168.46 | 02-JUN-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3611240.05 | 1952.70 | 09-JUL-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 3472665.04 | 1959.22 | 22-AUG-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 42915499.13 | 2477.01 | 21-SEP-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.151112E+09 | 2402.03 | 21-OCT-15:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.703315E+09 | 3823.75 | 26-NOV-19:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116429E+10 | 3914.86 | 13-DEC-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.573972E+10 | |||||||
Minimum of Months | 3472665.04 | 1952.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.122951E+10 | 3976.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORRIDOR_FLR_3 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.554707E+10 | 6762.36 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.492405E+10 | 6248.86 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.648841E+10 | 6382.19 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.440624E+10 | 5990.61 | 01-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.496803E+10 | 5344.90 | 14-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.408053E+10 | 3942.15 | 12-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.330176E+10 | 3549.48 | 10-JUL-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.298751E+10 | 3469.95 | 14-AUG-03:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.331471E+10 | 3735.76 | 23-SEP-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.275894E+10 | 4100.38 | 12-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.373825E+10 | 5992.24 | 08-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.475192E+10 | 6254.14 | 24-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.512674E+11 | |||||||
Minimum of Months | 0.275894E+10 | 3469.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.648841E+10 | 6762.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_6 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.287736E+09 | 1198.77 | 01-JAN-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.223250E+09 | 1212.30 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.304463E+09 | 1234.46 | 29-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 71497278.26 | 1178.65 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 66287949.06 | 762.26 | 20-MAY-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 12171980.97 | 586.42 | 06-JUN-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 706229.11 | 642.94 | 23-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1148066.39 | 575.37 | 31-AUG-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 4182293.57 | 535.17 | 13-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 35154682.21 | 795.73 | 14-OCT-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144831E+09 | 676.04 | 24-NOV-09:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.251225E+09 | 1196.31 | 12-DEC-19:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.140265E+10 | |||||||
Minimum of Months | 706229.11 | 535.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.304463E+09 | 1234.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_2_FLR_6 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.488901E+09 | 1219.16 | 12-JAN-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.321231E+09 | 1210.92 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.379851E+09 | 1229.59 | 29-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 93674855.33 | 1176.79 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 68885119.46 | 733.53 | 20-MAY-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 11862596.47 | 587.14 | 06-JUN-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 695206.78 | 673.59 | 23-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1362698.06 | 563.31 | 19-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 8269377.80 | 523.23 | 06-SEP-08:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 62115351.33 | 1181.27 | 30-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.261567E+09 | 1186.69 | 05-NOV-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.447293E+09 | 1211.97 | 13-DEC-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.214571E+10 | |||||||
Minimum of Months | 695206.78 | 523.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.488901E+09 | 1229.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COILHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.384105E+09 | 2685.98 | 08-JAN-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.324281E+09 | 5546.44 | 25-FEB-16:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.751299E+09 | 5679.76 | 29-MAR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.150975E+09 | 3337.22 | 18-APR-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.242622E+09 | 4439.57 | 12-MAY-15:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 36853691.04 | 3374.43 | 06-JUN-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 9304540.05 | 3240.63 | 15-JUL-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 5541212.77 | 2813.98 | 05-AUG-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6078725.86 | 2463.99 | 10-SEP-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 25701025.68 | 2666.65 | 23-OCT-15:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.112904E+09 | 2560.36 | 24-NOV-16:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.282268E+09 | 2446.57 | 13-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.233193E+10 | |||||||
Minimum of Months | 5541212.77 | 2446.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.751299E+09 | 5679.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: BANQUET_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 4618277.60 | 1305.44 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4618277.60 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 4618277.60 | 1305.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: DINING_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 1370896.84 | 865.81 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1370896.84 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 1370896.84 | 865.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: KITCHEN_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.313262E+09 | 4801.52 | 09-JAN-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 16423139.55 | 2166.24 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.213617E+09 | 4619.44 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5244726.79 | 1075.76 | 05-NOV-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 97760046.43 | 4195.10 | 24-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.646307E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.313262E+09 | 4801.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORRIDOR_FLR_6 VAV BOX REHEAT COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.149156E+10 | 4141.43 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.908386E+09 | 3218.39 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.135673E+10 | 3908.32 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.326108E+09 | 2699.70 | 01-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.318386E+09 | 2195.31 | 14-MAY-04:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 85647805.07 | 870.45 | 14-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 1049456.97 | 223.78 | 14-JUL-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 343043.76 | 90.45 | 24-AUG-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 54246141.30 | 682.88 | 20-SEP-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.134227E+09 | 1171.59 | 12-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.564626E+09 | 2462.29 | 05-NOV-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116521E+10 | 3447.88 | 13-DEC-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.640652E+10 | |||||||
Minimum of Months | 343043.76 | 90.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.149156E+10 | 4141.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: VAV WITH REHEAT_HEATC
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.806531E+11 | 86613.42 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.628981E+11 | 80143.42 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.863164E+11 | 81799.07 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.333013E+11 | 76881.65 | 15-APR-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.292188E+11 | 75256.78 | 14-MAY-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.302495E+10 | 52186.98 | 13-JUN-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.136340E+09 | 14603.50 | 06-JUL-01:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.168657E+10 | 51744.39 | 20-SEP-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.115021E+11 | 74407.49 | 12-OCT-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.528440E+11 | 78801.14 | 29-NOV-23:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.806053E+11 | 80432.81 | 12-DEC-22:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.442187E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.863164E+11 | 86613.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FLR_3_DOAS_HEATC
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.116457E+11 | 10725.70 | 08-JAN-07:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.101732E+11 | 9902.92 | 05-FEB-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.132557E+11 | 10112.22 | 30-MAR-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.686313E+10 | 9488.39 | 01-APR-06:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.577283E+10 | 9282.77 | 14-MAY-04:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.108118E+10 | 8690.84 | 13-JUN-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 62613326.23 | 4000.91 | 06-JUL-01:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 29986387.10 | 1527.87 | 24-AUG-02:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.541140E+09 | 8690.89 | 20-SEP-03:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.229530E+10 | 9073.08 | 28-OCT-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.868603E+10 | 9490.42 | 05-NOV-03:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.116436E+11 | 9905.85 | 24-DEC-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.720504E+11 | |||||||
Minimum of Months | 29986387.10 | 1527.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.132557E+11 | 10725.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ROOM_1_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.112253E+10 | 0.706986E+09 | 11224.91 | 14-JAN-16:01 | 11224.91 | 0.30 |
February | 0.00 | 0.00 | 0.105129E+10 | 0.686036E+09 | 10990.52 | 03-FEB-16:01 | 10990.52 | 0.27 |
March | 0.00 | 0.00 | 0.111418E+10 | 0.665597E+09 | 11119.15 | 10-MAR-16:01 | 11119.15 | 0.28 |
April | 0.00 | 0.00 | 0.230488E+10 | 0.129402E+10 | 11217.95 | 01-APR-15:02 | 11217.95 | 0.57 |
May | 0.00 | 0.00 | 0.210094E+10 | 0.113766E+10 | 11158.24 | 06-MAY-15:02 | 10182.26 | 0.57 |
June | 0.00 | 0.00 | 0.320116E+10 | 0.163581E+10 | 11596.82 | 28-JUN-15:02 | 10380.85 | 0.72 |
July | 0.00 | 0.00 | 0.485014E+10 | 0.246043E+10 | 12356.09 | 30-JUL-08:62 | 8762.43 | 0.79 |
August | 0.00 | 0.00 | 0.495852E+10 | 0.249051E+10 | 12478.36 | 19-AUG-08:62 | 9001.87 | 0.80 |
September | 0.00 | 0.00 | 0.370394E+10 | 0.187970E+10 | 12346.42 | 21-SEP-15:02 | 10246.07 | 0.78 |
October | 0.00 | 0.00 | 0.348901E+10 | 0.228133E+10 | 12492.66 | 01-OCT-08:62 | 8611.50 | 0.54 |
November | 0.00 | 0.00 | 0.154491E+10 | 0.935850E+09 | 11292.18 | 19-NOV-09:02 | 11292.18 | 0.40 |
December | 0.00 | 0.00 | 0.133407E+10 | 0.107692E+10 | 11214.31 | 05-DEC-16:01 | 11214.31 | 0.19 |
Annual Sum or Average | 0.307756E+11 | 0.172508E+11 | 0.52 | |||||
Minimum of Months | 0.00 | 0.00 | 0.105129E+10 | 0.665597E+09 | 10990.52 | 8611.50 | 0.19 | |
Maximum of Months | 0.00 | 0.00 | 0.495852E+10 | 0.249051E+10 | 12492.66 | 11292.18 | 0.80 |
Report: CoilReportMonthly
For: ROOM_2_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.225602E+09 | 0.139843E+09 | 10921.18 | 14-JAN-16:01 | 10921.18 | 0.10 |
February | 0.00 | 0.00 | 0.363653E+09 | 0.233642E+09 | 10733.03 | 03-FEB-16:01 | 10733.03 | 0.15 |
March | 0.00 | 0.00 | 0.617842E+09 | 0.368058E+09 | 11068.54 | 23-MAR-15:02 | 10135.32 | 0.18 |
April | 0.00 | 0.00 | 0.184807E+10 | 0.103316E+10 | 11068.20 | 11-APR-15:02 | 10286.16 | 0.50 |
May | 0.00 | 0.00 | 0.201094E+10 | 0.109596E+10 | 10894.45 | 06-MAY-15:02 | 9944.91 | 0.55 |
June | 0.00 | 0.00 | 0.324760E+10 | 0.168150E+10 | 11342.98 | 28-JUN-15:02 | 10127.37 | 0.72 |
July | 0.00 | 0.00 | 0.481658E+10 | 0.246267E+10 | 12068.33 | 30-JUL-08:62 | 8554.29 | 0.79 |
August | 0.00 | 0.00 | 0.452174E+10 | 0.223551E+10 | 12190.78 | 19-AUG-08:62 | 8751.08 | 0.78 |
September | 0.00 | 0.00 | 0.281403E+10 | 0.135917E+10 | 12104.57 | 21-SEP-15:02 | 9978.23 | 0.73 |
October | 0.00 | 0.00 | 0.220316E+10 | 0.134775E+10 | 12209.46 | 01-OCT-08:62 | 8260.79 | 0.45 |
November | 0.00 | 0.00 | 0.379800E+09 | 0.208144E+09 | 10801.77 | 10-NOV-16:02 | 9688.18 | 0.20 |
December | 0.00 | 0.00 | 0.225785E+09 | 0.191293E+09 | 10951.38 | 05-DEC-16:01 | 10951.38 | 0.05 |
Annual Sum or Average | 0.232748E+11 | 0.123567E+11 | 0.43 | |||||
Minimum of Months | 0.00 | 0.00 | 0.225602E+09 | 0.139843E+09 | 10733.03 | 8260.79 | 0.05 | |
Maximum of Months | 0.00 | 0.00 | 0.481658E+10 | 0.246267E+10 | 12209.46 | 10951.38 | 0.79 |
Report: CoilReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.175261E+11 | 0.149334E+11 | 36775.66 | 14-JAN-12:40 | 36775.66 | 0.25 |
February | 0.00 | 0.00 | 0.106611E+11 | 0.910015E+10 | 32816.28 | 02-FEB-12:40 | 32816.28 | 0.18 |
March | 0.00 | 0.00 | 0.366643E+10 | 0.216507E+10 | 20698.53 | 11-MAR-13:10 | 20698.53 | 0.16 |
April | 0.00 | 0.00 | 0.151425E+10 | 0.455689E+09 | 11281.76 | 08-APR-12:40 | 4936.79 | 0.14 |
May | 0.00 | 0.00 | 27903100.76 | 3484826.03 | 2056.45 | 04-MAY-13:30 | 308.45 | 0.01 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.856821E+09 | 0.155997E+09 | 9441.41 | 31-JUL-17:17 | 2596.40 | 0.13 |
August | 0.00 | 0.00 | 0.379931E+10 | 0.991999E+09 | 14371.28 | 18-AUG-15:10 | 5924.60 | 0.34 |
September | 0.00 | 0.00 | 0.879691E+10 | 0.474460E+10 | 33840.17 | 30-SEP-12:10 | 29694.45 | 0.36 |
October | 0.00 | 0.00 | 0.195239E+11 | 0.156636E+11 | 42890.37 | 16-OCT-12:10 | 42890.37 | 0.33 |
November | 0.00 | 0.00 | 0.187221E+11 | 0.156220E+11 | 39809.27 | 19-NOV-12:30 | 39809.27 | 0.29 |
December | 0.00 | 0.00 | 0.213969E+11 | 0.196028E+11 | 37656.80 | 19-DEC-13:00 | 37656.80 | 0.19 |
Annual Sum or Average | 0.106492E+12 | 0.834388E+11 | 0.20 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.213969E+11 | 0.196028E+11 | 42890.37 | 42890.37 | 0.36 |
Report: CoilReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.692624E+10 | 0.355905E+10 | 59645.18 | 15-JAN-09:02 | 59645.18 | 0.33 |
February | 0.00 | 0.00 | 0.780027E+10 | 0.403230E+10 | 60415.54 | 13-FEB-19:03 | 48376.50 | 0.43 |
March | 0.00 | 0.00 | 0.968705E+10 | 0.486864E+10 | 58073.33 | 23-MAR-15:02 | 53276.72 | 0.45 |
April | 0.00 | 0.00 | 0.170558E+11 | 0.856090E+10 | 60438.15 | 26-APR-08:62 | 53626.25 | 0.65 |
May | 0.00 | 0.00 | 0.206503E+11 | 0.112126E+11 | 60179.67 | 06-MAY-08:62 | 52092.95 | 0.68 |
June | 0.00 | 0.00 | 0.283751E+11 | 0.148923E+11 | 65515.67 | 29-JUN-18:02 | 54854.60 | 0.70 |
July | 0.00 | 0.00 | 0.371320E+11 | 0.196580E+11 | 73712.54 | 18-JUL-18:02 | 54308.45 | 0.71 |
August | 0.00 | 0.00 | 0.349077E+11 | 0.174647E+11 | 70613.83 | 19-AUG-08:62 | 53170.75 | 0.70 |
September | 0.00 | 0.00 | 0.244418E+11 | 0.114037E+11 | 67973.92 | 22-SEP-08:62 | 49087.44 | 0.70 |
October | 0.00 | 0.00 | 0.221874E+11 | 0.134603E+11 | 71689.60 | 01-OCT-08:62 | 50001.94 | 0.52 |
November | 0.00 | 0.00 | 0.937701E+10 | 0.507482E+10 | 61448.23 | 19-NOV-09:02 | 61448.23 | 0.42 |
December | 0.00 | 0.00 | 0.616996E+10 | 0.428585E+10 | 59710.91 | 05-DEC-09:02 | 59710.91 | 0.21 |
Annual Sum or Average | 0.224711E+12 | 0.118473E+12 | 0.54 | |||||
Minimum of Months | 0.00 | 0.00 | 0.616996E+10 | 0.355905E+10 | 58073.33 | 48376.50 | 0.21 | |
Maximum of Months | 0.00 | 0.00 | 0.371320E+11 | 0.196580E+11 | 73712.54 | 61448.23 | 0.71 |
Report: CoilReportMonthly
For: ROOM_5_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.122199E+10 | 0.861722E+09 | 9717.58 | 14-JAN-16:01 | 9717.58 | 0.29 |
February | 0.00 | 0.00 | 0.963673E+09 | 0.677259E+09 | 9584.62 | 01-FEB-09:02 | 9584.62 | 0.25 |
March | 0.00 | 0.00 | 0.108255E+10 | 0.663457E+09 | 9817.65 | 23-MAR-15:02 | 8990.41 | 0.29 |
April | 0.00 | 0.00 | 0.202208E+10 | 0.116900E+10 | 9770.81 | 30-APR-15:02 | 9150.61 | 0.51 |
May | 0.00 | 0.00 | 0.174723E+10 | 0.947063E+09 | 9807.22 | 03-MAY-08:62 | 8606.97 | 0.49 |
June | 0.00 | 0.00 | 0.256691E+10 | 0.131688E+10 | 10282.76 | 29-JUN-08:62 | 8012.78 | 0.62 |
July | 0.00 | 0.00 | 0.426282E+10 | 0.219364E+10 | 11052.44 | 31-JUL-15:02 | 8797.42 | 0.80 |
August | 0.00 | 0.00 | 0.460959E+10 | 0.234886E+10 | 10886.89 | 17-AUG-15:02 | 8991.97 | 0.85 |
September | 0.00 | 0.00 | 0.297917E+10 | 0.153462E+10 | 10775.91 | 09-SEP-08:62 | 8310.73 | 0.75 |
October | 0.00 | 0.00 | 0.322497E+10 | 0.219072E+10 | 10811.74 | 01-OCT-08:62 | 7432.10 | 0.53 |
November | 0.00 | 0.00 | 0.140600E+10 | 0.964159E+09 | 9824.84 | 19-NOV-09:02 | 9824.84 | 0.34 |
December | 0.00 | 0.00 | 0.132789E+10 | 0.113923E+10 | 9818.38 | 05-DEC-09:02 | 9818.38 | 0.18 |
Annual Sum or Average | 0.274149E+11 | 0.160066E+11 | 0.49 | |||||
Minimum of Months | 0.00 | 0.00 | 0.963673E+09 | 0.663457E+09 | 9584.62 | 7432.10 | 0.18 | |
Maximum of Months | 0.00 | 0.00 | 0.460959E+10 | 0.234886E+10 | 11052.44 | 9824.84 | 0.85 |
Report: CoilReportMonthly
For: ROOM_6_FLR_3 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.348531E+09 | 0.215745E+09 | 9404.32 | 21-JAN-09:02 | 7895.44 | 0.12 |
February | 0.00 | 0.00 | 0.334567E+09 | 0.227003E+09 | 9115.04 | 01-FEB-09:02 | 9115.04 | 0.13 |
March | 0.00 | 0.00 | 0.603417E+09 | 0.345017E+09 | 9439.75 | 23-MAR-15:02 | 8485.34 | 0.20 |
April | 0.00 | 0.00 | 0.161155E+10 | 0.918073E+09 | 9690.22 | 27-APR-08:62 | 8210.26 | 0.42 |
May | 0.00 | 0.00 | 0.167016E+10 | 0.907250E+09 | 9731.36 | 03-MAY-08:62 | 8508.77 | 0.48 |
June | 0.00 | 0.00 | 0.261244E+10 | 0.135157E+10 | 10179.12 | 29-JUN-08:62 | 7954.60 | 0.62 |
July | 0.00 | 0.00 | 0.422238E+10 | 0.218439E+10 | 10957.86 | 31-JUL-15:02 | 8701.84 | 0.79 |
August | 0.00 | 0.00 | 0.417053E+10 | 0.210885E+10 | 10976.15 | 17-AUG-15:02 | 8786.97 | 0.78 |
September | 0.00 | 0.00 | 0.215238E+10 | 0.106113E+10 | 10737.51 | 09-SEP-08:62 | 8188.54 | 0.64 |
October | 0.00 | 0.00 | 0.194549E+10 | 0.124262E+10 | 10717.61 | 01-OCT-08:62 | 7226.61 | 0.41 |
November | 0.00 | 0.00 | 0.409555E+09 | 0.260648E+09 | 9727.39 | 19-NOV-09:02 | 9727.39 | 0.16 |
December | 0.00 | 0.00 | 0.315095E+09 | 0.272762E+09 | 9720.63 | 05-DEC-09:02 | 9720.63 | 0.05 |
Annual Sum or Average | 0.203961E+11 | 0.110951E+11 | 0.40 | |||||
Minimum of Months | 0.00 | 0.00 | 0.315095E+09 | 0.215745E+09 | 9115.04 | 7226.61 | 0.05 | |
Maximum of Months | 0.00 | 0.00 | 0.422238E+10 | 0.218439E+10 | 10976.15 | 9727.39 | 0.79 |
Report: CoilReportMonthly
For: ROOM_1_FLR_6 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.277085E+09 | 0.182602E+09 | 2904.97 | 21-JAN-09:02 | 2118.89 | 0.24 |
February | 0.00 | 0.00 | 0.265385E+09 | 0.182587E+09 | 2838.49 | 03-FEB-16:01 | 2838.49 | 0.23 |
March | 0.00 | 0.00 | 0.300906E+09 | 0.191263E+09 | 2871.60 | 10-MAR-16:01 | 2871.60 | 0.25 |
April | 0.00 | 0.00 | 0.647849E+09 | 0.391631E+09 | 2971.27 | 26-APR-08:62 | 2289.11 | 0.52 |
May | 0.00 | 0.00 | 0.593437E+09 | 0.347167E+09 | 2936.99 | 03-MAY-08:62 | 2193.48 | 0.52 |
June | 0.00 | 0.00 | 0.933390E+09 | 0.515551E+09 | 3038.70 | 30-JUN-08:62 | 2259.35 | 0.70 |
July | 0.00 | 0.00 | 0.144124E+10 | 0.782567E+09 | 3291.80 | 23-JUL-08:62 | 2390.44 | 0.85 |
August | 0.00 | 0.00 | 0.146211E+10 | 0.777247E+09 | 3354.92 | 19-AUG-08:62 | 2263.19 | 0.86 |
September | 0.00 | 0.00 | 0.103915E+10 | 0.564059E+09 | 3214.02 | 09-SEP-08:62 | 2207.72 | 0.80 |
October | 0.00 | 0.00 | 0.960232E+09 | 0.648355E+09 | 3341.87 | 01-OCT-08:62 | 2153.07 | 0.53 |
November | 0.00 | 0.00 | 0.388021E+09 | 0.244936E+09 | 2889.15 | 19-NOV-09:02 | 2889.15 | 0.34 |
December | 0.00 | 0.00 | 0.326169E+09 | 0.271561E+09 | 2896.27 | 05-DEC-16:01 | 2896.27 | 0.15 |
Annual Sum or Average | 0.863498E+10 | 0.509953E+10 | 0.50 | |||||
Minimum of Months | 0.00 | 0.00 | 0.265385E+09 | 0.182587E+09 | 2838.49 | 2118.89 | 0.15 | |
Maximum of Months | 0.00 | 0.00 | 0.146211E+10 | 0.782567E+09 | 3354.92 | 2896.27 | 0.86 |
Report: CoilReportMonthly
For: ROOM_2_FLR_6 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 54664804.30 | 36359511.43 | 2831.44 | 14-JAN-16:01 | 2831.44 | 0.08 |
February | 0.00 | 0.00 | 90426369.58 | 63644277.53 | 2772.22 | 03-FEB-16:01 | 2772.22 | 0.11 |
March | 0.00 | 0.00 | 0.168297E+09 | 0.107380E+09 | 2818.98 | 23-MAR-15:02 | 2640.61 | 0.15 |
April | 0.00 | 0.00 | 0.524168E+09 | 0.315353E+09 | 2898.22 | 26-APR-08:62 | 2221.45 | 0.44 |
May | 0.00 | 0.00 | 0.570329E+09 | 0.336538E+09 | 2859.86 | 03-MAY-08:62 | 2127.71 | 0.50 |
June | 0.00 | 0.00 | 0.946106E+09 | 0.529544E+09 | 2961.26 | 30-JUN-08:62 | 2221.62 | 0.71 |
July | 0.00 | 0.00 | 0.143189E+10 | 0.784272E+09 | 3218.94 | 23-JUL-08:62 | 2339.44 | 0.84 |
August | 0.00 | 0.00 | 0.134042E+10 | 0.709538E+09 | 3280.20 | 19-AUG-08:62 | 2199.00 | 0.82 |
September | 0.00 | 0.00 | 0.791893E+09 | 0.415456E+09 | 3132.49 | 09-SEP-08:62 | 2126.14 | 0.72 |
October | 0.00 | 0.00 | 0.611117E+09 | 0.388789E+09 | 3272.37 | 01-OCT-08:62 | 2059.86 | 0.43 |
November | 0.00 | 0.00 | 92006801.71 | 54924289.66 | 2791.18 | 10-NOV-16:02 | 2501.63 | 0.14 |
December | 0.00 | 0.00 | 56436510.45 | 49181093.62 | 2828.64 | 05-DEC-16:01 | 2828.64 | 0.03 |
Annual Sum or Average | 0.667775E+10 | 0.379098E+10 | 0.42 | |||||
Minimum of Months | 0.00 | 0.00 | 54664804.30 | 36359511.43 | 2772.22 | 2059.86 | 0.03 | |
Maximum of Months | 0.00 | 0.00 | 0.143189E+10 | 0.784272E+09 | 3280.20 | 2831.44 | 0.84 |
Report: CoilReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COILCOOL COIL
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.603821E+10 | 0.493697E+10 | 12618.53 | 14-JAN-16:01 | 12618.53 | 0.50 |
February | 0.00 | 0.00 | 0.381126E+10 | 0.296771E+10 | 12356.08 | 03-FEB-16:01 | 12356.08 | 0.46 |
March | 0.00 | 0.00 | 0.293767E+10 | 0.186567E+10 | 12500.16 | 10-MAR-16:01 | 12500.16 | 0.47 |
April | 0.00 | 0.00 | 0.323370E+10 | 0.174589E+10 | 12786.43 | 30-APR-15:02 | 11816.42 | 0.66 |
May | 0.00 | 0.00 | 0.204645E+10 | 0.941322E+09 | 12574.86 | 04-MAY-15:02 | 11773.94 | 0.53 |
June | 0.00 | 0.00 | 0.306842E+10 | 0.136132E+10 | 13325.67 | 29-JUN-18:02 | 10839.92 | 0.65 |
July | 0.00 | 0.00 | 0.531312E+10 | 0.253168E+10 | 14823.78 | 18-JUL-18:02 | 10784.73 | 0.75 |
August | 0.00 | 0.00 | 0.661199E+10 | 0.325427E+10 | 14248.28 | 19-AUG-08:62 | 10294.81 | 0.85 |
September | 0.00 | 0.00 | 0.647149E+10 | 0.356354E+10 | 13681.88 | 21-SEP-15:02 | 11643.78 | 0.86 |
October | 0.00 | 0.00 | 0.815514E+10 | 0.612149E+10 | 14276.39 | 01-OCT-08:62 | 9924.75 | 0.62 |
November | 0.00 | 0.00 | 0.617050E+10 | 0.484881E+10 | 12747.17 | 19-NOV-09:02 | 12747.17 | 0.58 |
December | 0.00 | 0.00 | 0.666546E+10 | 0.593634E+10 | 12738.31 | 05-DEC-09:02 | 12738.31 | 0.34 |
Annual Sum or Average | 0.605234E+11 | 0.400750E+11 | 0.61 | |||||
Minimum of Months | 0.00 | 0.00 | 0.204645E+10 | 0.941322E+09 | 12356.08 | 9924.75 | 0.34 | |
Maximum of Months | 0.00 | 0.00 | 0.815514E+10 | 0.612149E+10 | 14823.78 | 12747.17 | 0.86 |
Report: CoilReportMonthly
For: VAV WITH REHEAT_COOLC
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.826818E+11 | 0.813995E+11 | 220307.08 | 14-JAN-11:50 | 220307.08 | 0.26 |
February | 0.00 | 0.00 | 0.521232E+11 | 0.490111E+11 | 213797.68 | 01-FEB-12:00 | 213797.68 | 0.26 |
March | 0.00 | 0.00 | 0.546345E+11 | 0.507150E+11 | 225052.63 | 23-MAR-15:03 | 150863.54 | 0.26 |
April | 0.00 | 0.00 | 0.119133E+12 | 0.110144E+12 | 271622.90 | 26-APR-11:00 | 215887.09 | 0.50 |
May | 0.00 | 0.00 | 0.128423E+12 | 0.123174E+12 | 191738.81 | 04-MAY-13:00 | 167498.38 | 0.60 |
June | 0.00 | 0.00 | 0.252532E+12 | 0.195867E+12 | 334048.38 | 29-JUN-11:00 | 201155.15 | 0.92 |
July | 0.00 | 0.00 | 0.484291E+12 | 0.285666E+12 | 415998.57 | 19-JUL-12:00 | 247360.77 | 1.00 |
August | 0.00 | 0.00 | 0.542108E+12 | 0.296186E+12 | 423520.61 | 14-AUG-10:50 | 250084.57 | 1.00 |
September | 0.00 | 0.00 | 0.337646E+12 | 0.230316E+12 | 450007.81 | 22-SEP-12:00 | 215919.83 | 0.93 |
October | 0.00 | 0.00 | 0.340060E+12 | 0.259305E+12 | 410847.62 | 01-OCT-12:00 | 216648.01 | 0.61 |
November | 0.00 | 0.00 | 0.907051E+11 | 0.857472E+11 | 233998.42 | 19-NOV-13:00 | 233998.42 | 0.32 |
December | 0.00 | 0.00 | 0.917404E+11 | 0.916011E+11 | 216762.41 | 16-DEC-13:00 | 216762.41 | 0.12 |
Annual Sum or Average | 0.257608E+13 | 0.185913E+13 | 0.57 | |||||
Minimum of Months | 0.00 | 0.00 | 0.521232E+11 | 0.490111E+11 | 191738.81 | 150863.54 | 0.12 | |
Maximum of Months | 0.00 | 0.00 | 0.542108E+12 | 0.296186E+12 | 450007.81 | 250084.57 | 1.00 |
Report: CoilReportMonthly
For: FLR_3_DOAS_COOLC
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.112658E+11 | 0.111536E+11 | 34743.62 | 13-JAN-14:00 | 34743.62 | 0.20 |
February | 0.00 | 0.00 | 0.622464E+10 | 0.601657E+10 | 34694.04 | 01-FEB-12:00 | 34694.04 | 0.18 |
March | 0.00 | 0.00 | 0.716323E+10 | 0.662317E+10 | 37275.62 | 23-MAR-15:00 | 25053.49 | 0.20 |
April | 0.00 | 0.00 | 0.167384E+11 | 0.156668E+11 | 44342.00 | 26-APR-11:00 | 34956.49 | 0.41 |
May | 0.00 | 0.00 | 0.173875E+11 | 0.169834E+11 | 31869.69 | 04-MAY-13:10 | 27471.34 | 0.49 |
June | 0.00 | 0.00 | 0.349109E+11 | 0.277543E+11 | 54358.03 | 29-JUN-11:00 | 32597.26 | 0.84 |
July | 0.00 | 0.00 | 0.710409E+11 | 0.427184E+11 | 65145.73 | 31-JUL-12:20 | 39024.52 | 0.99 |
August | 0.00 | 0.00 | 0.800063E+11 | 0.445962E+11 | 65121.07 | 14-AUG-11:00 | 39035.53 | 0.99 |
September | 0.00 | 0.00 | 0.471891E+11 | 0.333172E+11 | 67382.89 | 22-SEP-12:00 | 32723.70 | 0.89 |
October | 0.00 | 0.00 | 0.517453E+11 | 0.393188E+11 | 63638.29 | 01-OCT-12:00 | 33841.30 | 0.58 |
November | 0.00 | 0.00 | 0.115868E+11 | 0.113554E+11 | 37149.32 | 19-NOV-13:00 | 37149.32 | 0.25 |
December | 0.00 | 0.00 | 0.131181E+11 | 0.131057E+11 | 34602.16 | 16-DEC-13:00 | 34602.16 | 0.08 |
Annual Sum or Average | 0.368377E+12 | 0.268610E+12 | 0.51 | |||||
Minimum of Months | 0.00 | 0.00 | 0.622464E+10 | 0.601657E+10 | 31869.69 | 25053.49 | 0.08 | |
Maximum of Months | 0.00 | 0.00 | 0.800063E+11 | 0.445962E+11 | 67382.89 | 39035.53 | 0.99 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 24009.61 | 49050.99 | 23-JAN-07:10 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 24066.49 | 49062.35 | 13-FEB-07:10 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 23710.35 | 48878.58 | 01-MAR-07:10 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23198.18 | 47894.32 | 03-APR-07:00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 22530.87 | 46913.68 | 02-MAY-06:45 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 21904.59 | 45702.28 | 02-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 21615.60 | 44771.29 | 03-JUL-06:20 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 21602.77 | 44756.39 | 31-AUG-06:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21810.76 | 45479.17 | 29-SEP-06:15 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 22399.29 | 46652.31 | 31-OCT-06:10 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 22973.58 | 47804.62 | 30-NOV-07:15 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 23619.06 | 48671.35 | 28-DEC-07:10 |
Annual Sum or Average | 0.00 | 22779.70 | ||||
Minimum of Months | 0.00 | 0.00 | 21602.77 | 44756.39 | ||
Maximum of Months | 0.00 | 0.00 | 24066.49 | 49062.35 |
Report: PlantLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 41629.69 | 169852.34 | 08-JAN-07:00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 35279.83 | 128646.18 | 05-FEB-06:00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 44047.23 | 151682.65 | 30-MAR-03:00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 18819.28 | 114670.89 | 01-APR-05:00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 16856.29 | 103954.99 | 14-MAY-04:50 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 5385.66 | 70504.01 | 13-JUN-04:00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 3262.36 | 42930.66 | 11-JUL-15:05 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 2964.02 | 41888.38 | 14-AUG-08:05 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 3845.67 | 68428.22 | 20-SEP-04:00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 7942.25 | 96186.00 | 28-OCT-05:00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 27319.45 | 116248.50 | 24-NOV-04:00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 40255.51 | 132518.10 | 24-DEC-04:00 |
Annual Sum or Average | 0.00 | 20587.99 | ||||
Minimum of Months | 0.00 | 0.00 | 2964.02 | 41888.38 | ||
Maximum of Months | 0.00 | 0.00 | 44047.23 | 169852.34 |
Report: PlantLoopDemandReportMonthly
For: COOLSYS1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 50210.40 | 330325.98 | 14-JAN-16:01 | 0.00 | 0.00 | 01-JAN-00:05 |
February | 37016.07 | 313913.51 | 01-FEB-09:02 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 32740.65 | 385326.92 | 23-MAR-15:02 | 0.00 | 0.00 | 01-MAR-00:03 |
April | 67392.05 | 372262.93 | 11-APR-15:02 | 0.00 | 0.00 | 01-APR-00:10 |
May | 69438.74 | 382239.47 | 18-MAY-15:02 | 0.00 | 0.00 | 01-MAY-00:05 |
June | 132207.42 | 466130.55 | 29-JUN-18:03 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 235954.57 | 575549.51 | 31-JUL-15:02 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 261774.54 | 602862.22 | 18-AUG-15:02 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 173235.81 | 549615.58 | 21-SEP-15:02 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 173599.25 | 529530.69 | 14-OCT-15:02 | 0.00 | 0.00 | 01-OCT-00:05 |
November | 57201.26 | 378665.90 | 19-NOV-09:02 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 55829.70 | 365123.90 | 05-DEC-09:02 | 0.00 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 112886.38 | 0.00 | ||||
Minimum of Months | 32740.65 | 313913.51 | 0.00 | 0.00 | ||
Maximum of Months | 261774.54 | 602862.22 | 0.00 | 0.00 |
Report: FanReportMonthly
For: FLR_3_DOAS_FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.587767E+10 | 0.89 | 2194.47 | 02-JAN-00:20 | 0.89 |
February | 0.530887E+10 | 0.89 | 2194.47 | 01-FEB-09:50 | 0.89 |
March | 0.587767E+10 | 0.89 | 2194.47 | 01-MAR-01:00 | 0.89 |
April | 0.568807E+10 | 0.89 | 2194.47 | 01-APR-01:20 | 0.89 |
May | 0.587767E+10 | 0.89 | 2194.47 | 01-MAY-08:04 | 0.89 |
June | 0.568807E+10 | 0.89 | 2194.47 | 01-JUN-15:03 | 0.89 |
July | 0.587767E+10 | 0.89 | 2194.47 | 01-JUL-15:08 | 0.89 |
August | 0.587767E+10 | 0.89 | 2194.47 | 01-AUG-15:15 | 0.89 |
September | 0.568807E+10 | 0.89 | 2194.47 | 01-SEP-16:10 | 0.89 |
October | 0.587767E+10 | 0.89 | 2194.47 | 01-OCT-18:15 | 0.89 |
November | 0.568807E+10 | 0.89 | 2194.47 | 01-NOV-08:50 | 0.89 |
December | 0.587767E+10 | 0.89 | 2194.47 | 01-DEC-16:02 | 0.89 |
Annual Sum or Average | 0.692049E+11 | 0.89 | |||
Minimum of Months | 0.530887E+10 | 0.89 | 2194.47 | 0.89 | |
Maximum of Months | 0.587767E+10 | 0.89 | 2194.47 | 0.89 |
Report: FanReportMonthly
For: VAV WITH REHEAT_FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.376514E+11 | 0.91 | 21103.50 | 04-JAN-21:50 | 1.17 |
February | 0.347166E+11 | 0.92 | 21972.09 | 03-FEB-21:40 | 1.20 |
March | 0.384451E+11 | 0.92 | 21551.61 | 02-MAR-21:10 | 1.18 |
April | 0.371783E+11 | 0.92 | 21319.87 | 06-APR-20:30 | 1.17 |
May | 0.383128E+11 | 0.92 | 21718.08 | 10-MAY-20:10 | 1.18 |
June | 0.363829E+11 | 0.91 | 21397.25 | 12-JUN-21:00 | 1.17 |
July | 0.369701E+11 | 0.90 | 19305.62 | 07-JUL-21:00 | 1.09 |
August | 0.369739E+11 | 0.90 | 19464.05 | 21-AUG-20:00 | 1.10 |
September | 0.358700E+11 | 0.90 | 20345.64 | 18-SEP-21:00 | 1.13 |
October | 0.370379E+11 | 0.90 | 20987.76 | 11-OCT-21:00 | 1.16 |
November | 0.370657E+11 | 0.92 | 21788.30 | 22-NOV-22:00 | 1.20 |
December | 0.378371E+11 | 0.92 | 21444.18 | 20-DEC-21:30 | 1.17 |
Annual Sum or Average | 0.444442E+12 | 0.91 | |||
Minimum of Months | 0.347166E+11 | 0.90 | 19305.62 | 1.09 | |
Maximum of Months | 0.384451E+11 | 0.92 | 21972.09 | 1.20 |
Report: FanReportMonthly
For: LAUNDRY_FLR_1 EXHAUST FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.205205E+09 | 0.27 | 76.61 | 01-JAN-00:05 | 0.27 |
February | 0.185347E+09 | 0.27 | 76.61 | 01-FEB-00:03 | 0.27 |
March | 0.205205E+09 | 0.27 | 76.61 | 01-MAR-00:03 | 0.27 |
April | 0.198586E+09 | 0.27 | 76.61 | 01-APR-00:10 | 0.27 |
May | 0.205205E+09 | 0.27 | 76.61 | 01-MAY-00:05 | 0.27 |
June | 0.198586E+09 | 0.27 | 76.61 | 01-JUN-00:10 | 0.27 |
July | 0.205205E+09 | 0.27 | 76.61 | 01-JUL-00:10 | 0.27 |
August | 0.205205E+09 | 0.27 | 76.61 | 01-AUG-00:10 | 0.27 |
September | 0.198586E+09 | 0.27 | 76.61 | 01-SEP-00:10 | 0.27 |
October | 0.205205E+09 | 0.27 | 76.61 | 01-OCT-00:05 | 0.27 |
November | 0.198586E+09 | 0.27 | 76.61 | 01-NOV-00:10 | 0.27 |
December | 0.205205E+09 | 0.27 | 76.61 | 01-DEC-00:03 | 0.27 |
Annual Sum or Average | 0.241613E+10 | 0.27 | |||
Minimum of Months | 0.185347E+09 | 0.27 | 76.61 | 0.27 | |
Maximum of Months | 0.205205E+09 | 0.27 | 76.61 | 0.27 |
Report: FanReportMonthly
For: LOBBY_FLR_1 DUMMY EXHAUST FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: DINING_FLR_6 DUMMY EXHAUST FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | -0.0 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | -0.0 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | -0.0 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | -0.0 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | -0.0 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | -0.0 | 0.00 | 01-OCT-00:05 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | -0.0 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: BANQUET_FLR_6 DUMMY EXHAUST FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | -0.0 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:03 | 0.00 |
March | 0.00 | -0.0 | 0.00 | 01-MAR-00:03 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:05 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | -0.0 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 0.00 |
November | 0.00 | -0.0 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | -0.0 | 0.00 | 01-DEC-00:03 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | -0.0 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: KITCHEN_FLR_6 EXHAUST FAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.116283E+10 | 0.19 | 612.92 | 01-JAN-07:03 | 0.27 |
February | 0.105030E+10 | 0.19 | 612.92 | 01-FEB-07:05 | 0.27 |
March | 0.116283E+10 | 0.19 | 612.92 | 01-MAR-07:03 | 0.27 |
April | 0.112532E+10 | 0.19 | 612.92 | 01-APR-06:05 | 0.27 |
May | 0.116283E+10 | 0.19 | 612.92 | 01-MAY-06:05 | 0.27 |
June | 0.112532E+10 | 0.19 | 612.92 | 01-JUN-06:05 | 0.27 |
July | 0.116283E+10 | 0.19 | 612.92 | 01-JUL-06:05 | 0.27 |
August | 0.116283E+10 | 0.19 | 612.92 | 01-AUG-06:03 | 0.27 |
September | 0.112532E+10 | 0.19 | 612.92 | 01-SEP-06:05 | 0.27 |
October | 0.116283E+10 | 0.19 | 612.92 | 01-OCT-06:03 | 0.27 |
November | 0.112532E+10 | 0.19 | 612.92 | 01-NOV-06:05 | 0.27 |
December | 0.116283E+10 | 0.19 | 612.92 | 01-DEC-07:05 | 0.27 |
Annual Sum or Average | 0.136914E+11 | 0.19 | |||
Minimum of Months | 0.105030E+10 | 0.19 | 612.92 | 0.27 | |
Maximum of Months | 0.116283E+10 | 0.19 | 612.92 | 0.27 |
Report: FanReportMonthly
For: ROOM_1_FLR_3 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.161218E+09 | 0.46 | 628.52 | 01-JAN-19:03 | 0.58 |
February | 0.142254E+09 | 0.45 | 628.52 | 01-FEB-16:02 | 0.58 |
March | 0.164853E+09 | 0.43 | 628.52 | 01-MAR-16:01 | 0.58 |
April | 0.163437E+09 | 0.44 | 628.52 | 01-APR-15:02 | 0.59 |
May | 0.152840E+09 | 0.43 | 628.52 | 01-MAY-15:02 | 0.58 |
June | 0.182823E+09 | 0.44 | 628.52 | 01-JUN-15:02 | 0.58 |
July | 0.250763E+09 | 0.46 | 628.52 | 01-JUL-08:62 | 0.58 |
August | 0.252336E+09 | 0.47 | 628.52 | 01-AUG-15:02 | 0.58 |
September | 0.203424E+09 | 0.46 | 628.52 | 01-SEP-15:02 | 0.58 |
October | 0.208282E+09 | 0.48 | 628.52 | 01-OCT-08:62 | 0.58 |
November | 0.145678E+09 | 0.47 | 628.52 | 01-NOV-15:02 | 0.58 |
December | 0.166106E+09 | 0.47 | 628.52 | 02-DEC-16:02 | 0.58 |
Annual Sum or Average | 0.219401E+10 | 0.46 | |||
Minimum of Months | 0.142254E+09 | 0.43 | 628.52 | 0.58 | |
Maximum of Months | 0.252336E+09 | 0.48 | 628.52 | 0.59 |
Report: FanReportMonthly
For: ROOM_2_FLR_3 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.161284E+09 | 0.42 | 613.65 | 01-JAN-09:02 | 0.58 |
February | 0.128171E+09 | 0.42 | 613.65 | 01-FEB-16:02 | 0.58 |
March | 0.157281E+09 | 0.42 | 613.65 | 01-MAR-09:02 | 0.58 |
April | 0.145116E+09 | 0.43 | 613.65 | 01-APR-15:02 | 0.59 |
May | 0.147871E+09 | 0.43 | 613.65 | 01-MAY-15:02 | 0.58 |
June | 0.184543E+09 | 0.44 | 613.65 | 01-JUN-15:02 | 0.58 |
July | 0.248698E+09 | 0.46 | 613.65 | 01-JUL-08:62 | 0.58 |
August | 0.231603E+09 | 0.46 | 613.65 | 01-AUG-15:02 | 0.58 |
September | 0.160925E+09 | 0.44 | 613.65 | 01-SEP-15:02 | 0.58 |
October | 0.149272E+09 | 0.44 | 613.65 | 01-OCT-08:62 | 0.58 |
November | 0.111965E+09 | 0.42 | 613.65 | 01-NOV-15:02 | 0.58 |
December | 0.151551E+09 | 0.42 | 613.65 | 02-DEC-16:02 | 0.58 |
Annual Sum or Average | 0.197828E+10 | 0.43 | |||
Minimum of Months | 0.111965E+09 | 0.42 | 613.65 | 0.58 | |
Maximum of Months | 0.248698E+09 | 0.46 | 613.65 | 0.59 |
Report: FanReportMonthly
For: ROOM_3_MULT19_FLR_3 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.975413E+09 | 0.29 | 2250.22 | 22-JAN-13:00 | 0.58 |
February | 0.574315E+09 | 0.22 | 2098.92 | 02-FEB-14:10 | 0.59 |
March | 0.211709E+09 | 0.12 | 909.23 | 11-MAR-13:10 | 0.59 |
April | 99069318.50 | 0.08 | 525.00 | 08-APR-12:40 | 0.58 |
May | 2824183.19 | 0.00 | 171.82 | 01-MAY-07:00 | 0.58 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 57456486.86 | 0.07 | 404.71 | 31-JUL-17:20 | 0.58 |
August | 0.217616E+09 | 0.20 | 570.64 | 18-AUG-15:10 | 0.58 |
September | 0.444991E+09 | 0.23 | 2027.24 | 30-SEP-13:20 | 0.59 |
October | 0.975602E+09 | 0.32 | 3027.79 | 31-OCT-13:10 | 0.59 |
November | 0.101094E+10 | 0.31 | 2009.24 | 18-NOV-13:30 | 0.59 |
December | 0.116758E+10 | 0.31 | 2131.78 | 03-DEC-12:50 | 0.58 |
Annual Sum or Average | 0.573752E+10 | 0.18 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.116758E+10 | 0.32 | 3027.79 | 0.59 |
Report: FanReportMonthly
For: ROOM_4_MULT19_FLR_3 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.820936E+09 | 0.41 | 3533.85 | 01-JAN-09:02 | 0.58 |
February | 0.652661E+09 | 0.41 | 3533.85 | 01-FEB-19:02 | 0.58 |
March | 0.820432E+09 | 0.41 | 3533.85 | 03-MAR-16:02 | 0.58 |
April | 0.952206E+09 | 0.41 | 3533.85 | 01-APR-08:62 | 0.59 |
May | 0.111979E+10 | 0.41 | 3533.85 | 01-MAY-15:02 | 0.58 |
June | 0.133497E+10 | 0.41 | 3533.85 | 01-JUN-15:02 | 0.58 |
July | 0.162730E+10 | 0.41 | 3533.85 | 01-JUL-08:62 | 0.58 |
August | 0.150055E+10 | 0.41 | 3533.85 | 01-AUG-08:62 | 0.58 |
September | 0.116516E+10 | 0.41 | 3533.85 | 01-SEP-15:02 | 0.58 |
October | 0.116007E+10 | 0.41 | 3533.85 | 01-OCT-08:62 | 0.58 |
November | 0.729102E+09 | 0.41 | 3533.85 | 01-NOV-08:62 | 0.58 |
December | 0.745223E+09 | 0.41 | 3533.85 | 02-DEC-09:02 | 0.58 |
Annual Sum or Average | 0.126284E+11 | 0.41 | |||
Minimum of Months | 0.652661E+09 | 0.41 | 3533.85 | 0.58 | |
Maximum of Months | 0.162730E+10 | 0.41 | 3533.85 | 0.59 |
Report: FanReportMonthly
For: ROOM_5_FLR_3 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.153761E+09 | 0.44 | 543.63 | 01-JAN-09:02 | 0.58 |
February | 0.134376E+09 | 0.43 | 543.63 | 01-FEB-09:02 | 0.59 |
March | 0.157024E+09 | 0.43 | 543.63 | 01-MAR-09:02 | 0.58 |
April | 0.145135E+09 | 0.44 | 543.63 | 01-APR-08:62 | 0.59 |
May | 0.132185E+09 | 0.42 | 543.63 | 01-MAY-08:62 | 0.58 |
June | 0.143888E+09 | 0.42 | 543.63 | 01-JUN-08:62 | 0.58 |
July | 0.212561E+09 | 0.47 | 543.63 | 01-JUL-08:62 | 0.58 |
August | 0.228167E+09 | 0.49 | 543.63 | 01-AUG-08:62 | 0.58 |
September | 0.163624E+09 | 0.46 | 543.63 | 01-SEP-08:62 | 0.58 |
October | 0.193585E+09 | 0.49 | 543.63 | 01-OCT-08:62 | 0.58 |
November | 0.137198E+09 | 0.44 | 543.63 | 01-NOV-08:62 | 0.58 |
December | 0.156970E+09 | 0.46 | 543.63 | 01-DEC-09:02 | 0.58 |
Annual Sum or Average | 0.195847E+10 | 0.45 | |||
Minimum of Months | 0.132185E+09 | 0.42 | 543.63 | 0.58 | |
Maximum of Months | 0.228167E+09 | 0.49 | 543.63 | 0.59 |
Report: FanReportMonthly
For: ROOM_6_FLR_3 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.149415E+09 | 0.41 | 538.19 | 01-JAN-09:02 | 0.58 |
February | 0.121767E+09 | 0.41 | 538.19 | 01-FEB-09:02 | 0.59 |
March | 0.148609E+09 | 0.41 | 538.19 | 01-MAR-09:02 | 0.58 |
April | 0.130644E+09 | 0.42 | 538.19 | 01-APR-08:62 | 0.59 |
May | 0.129242E+09 | 0.42 | 538.19 | 01-MAY-08:62 | 0.58 |
June | 0.146257E+09 | 0.42 | 538.19 | 01-JUN-08:62 | 0.58 |
July | 0.210715E+09 | 0.46 | 538.19 | 01-JUL-08:62 | 0.58 |
August | 0.205332E+09 | 0.46 | 538.19 | 01-AUG-08:62 | 0.58 |
September | 0.123524E+09 | 0.42 | 538.19 | 01-SEP-08:62 | 0.58 |
October | 0.133470E+09 | 0.43 | 538.19 | 01-OCT-08:62 | 0.58 |
November | 0.113025E+09 | 0.41 | 538.19 | 01-NOV-08:62 | 0.58 |
December | 0.144666E+09 | 0.41 | 538.19 | 01-DEC-16:02 | 0.58 |
Annual Sum or Average | 0.175667E+10 | 0.42 | |||
Minimum of Months | 0.113025E+09 | 0.41 | 538.19 | 0.58 | |
Maximum of Months | 0.210715E+09 | 0.46 | 538.19 | 0.59 |
Report: FanReportMonthly
For: ROOM_1_FLR_6 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 47351988.28 | 0.46 | 162.37 | 01-JAN-19:03 | 0.58 |
February | 42657008.12 | 0.45 | 162.37 | 01-FEB-16:02 | 0.58 |
March | 49885094.63 | 0.44 | 162.37 | 01-MAR-16:01 | 0.58 |
April | 48364512.65 | 0.46 | 162.37 | 01-APR-08:62 | 0.59 |
May | 45358842.98 | 0.44 | 162.37 | 01-MAY-15:02 | 0.58 |
June | 53719882.24 | 0.46 | 162.37 | 01-JUN-15:02 | 0.58 |
July | 74829739.50 | 0.49 | 162.37 | 01-JUL-08:62 | 0.58 |
August | 75140658.92 | 0.50 | 162.37 | 01-AUG-15:02 | 0.58 |
September | 57284799.75 | 0.49 | 162.37 | 01-SEP-15:02 | 0.58 |
October | 58702237.44 | 0.49 | 162.37 | 01-OCT-08:62 | 0.58 |
November | 41918934.19 | 0.47 | 162.37 | 01-NOV-15:02 | 0.58 |
December | 47937887.74 | 0.47 | 162.37 | 02-DEC-16:02 | 0.58 |
Annual Sum or Average | 0.643152E+09 | 0.47 | |||
Minimum of Months | 41918934.19 | 0.44 | 162.37 | 0.58 | |
Maximum of Months | 75140658.92 | 0.50 | 162.37 | 0.59 |
Report: FanReportMonthly
For: ROOM_2_FLR_6 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 50493506.90 | 0.42 | 158.55 | 01-JAN-09:02 | 0.58 |
February | 39908530.48 | 0.42 | 158.55 | 01-FEB-16:02 | 0.58 |
March | 48357499.18 | 0.42 | 158.55 | 01-MAR-09:02 | 0.58 |
April | 43804624.14 | 0.44 | 158.55 | 01-APR-08:62 | 0.59 |
May | 44222241.93 | 0.44 | 158.55 | 01-MAY-15:02 | 0.58 |
June | 54267287.24 | 0.46 | 158.55 | 01-JUN-15:02 | 0.58 |
July | 74434914.90 | 0.49 | 158.55 | 01-JUL-08:62 | 0.58 |
August | 68984987.37 | 0.48 | 158.55 | 01-AUG-15:02 | 0.58 |
September | 45540940.78 | 0.45 | 158.55 | 01-SEP-15:02 | 0.58 |
October | 43355393.40 | 0.45 | 158.55 | 01-OCT-08:62 | 0.58 |
November | 36000865.12 | 0.43 | 158.55 | 01-NOV-15:02 | 0.58 |
December | 47948566.19 | 0.42 | 158.55 | 01-DEC-09:02 | 0.58 |
Annual Sum or Average | 0.597319E+09 | 0.44 | |||
Minimum of Months | 36000865.12 | 0.42 | 158.55 | 0.58 | |
Maximum of Months | 74434914.90 | 0.49 | 158.55 | 0.59 |
Report: FanReportMonthly
For: ROOM_3_MULT9_FLR_6 FAN COILFAN
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.401177E+09 | 0.51 | 699.08 | 01-JAN-09:02 | 0.58 |
February | 0.267544E+09 | 0.48 | 699.08 | 01-FEB-09:02 | 0.59 |
March | 0.243434E+09 | 0.47 | 699.08 | 01-MAR-09:02 | 0.58 |
April | 0.199619E+09 | 0.47 | 699.08 | 01-APR-15:02 | 0.59 |
May | 0.151349E+09 | 0.42 | 699.08 | 01-MAY-15:02 | 0.58 |
June | 0.165928E+09 | 0.41 | 699.08 | 01-JUN-15:02 | 0.58 |
July | 0.253803E+09 | 0.44 | 699.08 | 01-JUL-08:62 | 0.58 |
August | 0.311874E+09 | 0.49 | 699.08 | 01-AUG-15:02 | 0.58 |
September | 0.324315E+09 | 0.51 | 699.08 | 01-SEP-15:02 | 0.58 |
October | 0.443263E+09 | 0.51 | 699.08 | 01-OCT-08:62 | 0.58 |
November | 0.375935E+09 | 0.51 | 699.08 | 01-NOV-08:62 | 0.58 |
December | 0.435327E+09 | 0.52 | 699.08 | 01-DEC-09:02 | 0.58 |
Annual Sum or Average | 0.357357E+10 | 0.48 | |||
Minimum of Months | 0.151349E+09 | 0.41 | 699.08 | 0.58 | |
Maximum of Months | 0.443263E+09 | 0.52 | 699.08 | 0.59 |
Report: PumpReportMonthly
For: HEATSYS1 PUMP
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPUMP ELECTRIC ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRIC POWER {Maximum}[W] | PUMP ELECTRIC POWER {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.128575E+10 | 0.115717E+10 | 1242.12 | 08-JAN-07:00 | 1117.91 | 1117.91 | 49.07 | 4.21 |
February | 0.105321E+10 | 0.947885E+09 | 1188.71 | 05-FEB-06:00 | 1069.84 | 1069.84 | 49.32 | 3.52 |
March | 0.136996E+10 | 0.123296E+10 | 1235.81 | 30-MAR-03:05 | 1112.22 | 1112.22 | 49.44 | 4.14 |
April | 0.596288E+09 | 0.536659E+09 | 1171.93 | 01-APR-05:00 | 1054.74 | 1054.74 | 49.25 | 3.30 |
May | 0.552518E+09 | 0.497266E+09 | 1139.63 | 14-MAY-04:50 | 1025.67 | 1025.67 | 49.10 | 2.94 |
June | 0.175581E+09 | 0.158023E+09 | 880.70 | 13-JUN-04:00 | 792.63 | 792.63 | 46.63 | 1.59 |
July | 0.113408E+09 | 0.102067E+09 | 504.35 | 09-JUL-15:05 | 453.92 | 453.92 | 43.51 | 0.72 |
August | 0.108095E+09 | 97285426.35 | 454.58 | 14-AUG-08:05 | 409.13 | 409.13 | 41.54 | 0.64 |
September | 0.134195E+09 | 0.120776E+09 | 864.35 | 20-SEP-04:00 | 777.91 | 777.91 | 46.60 | 1.54 |
October | 0.279033E+09 | 0.251130E+09 | 1115.97 | 28-OCT-05:00 | 1004.37 | 1004.37 | 48.96 | 2.73 |
November | 0.877815E+09 | 0.790034E+09 | 1173.20 | 24-NOV-04:00 | 1055.88 | 1055.88 | 49.34 | 3.32 |
December | 0.128099E+10 | 0.115289E+10 | 1198.68 | 24-DEC-04:00 | 1078.81 | 1078.81 | 49.39 | 3.66 |
Annual Sum or Average | 0.782684E+10 | 0.704415E+10 | ||||||
Minimum of Months | 0.108095E+09 | 97285426.35 | 454.58 | 409.13 | 409.13 | 41.54 | 0.64 | |
Maximum of Months | 0.136996E+10 | 0.123296E+10 | 1242.12 | 1117.91 | 1117.91 | 49.44 | 4.21 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP SECONDARY
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPUMP ELECTRIC ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRIC POWER {Maximum}[W] | PUMP ELECTRIC POWER {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.357287E+10 | 0.321558E+10 | 4306.69 | 24-JAN-16:02 | 3876.02 | 3876.02 | 7.15 | 12.94 |
February | 0.277909E+10 | 0.250118E+10 | 4093.05 | 01-FEB-13:10 | 3683.75 | 3683.75 | 7.23 | 10.66 |
March | 0.255144E+10 | 0.229630E+10 | 4297.47 | 23-MAR-15:02 | 3867.73 | 3867.73 | 7.43 | 12.82 |
April | 0.441462E+10 | 0.397316E+10 | 4212.17 | 11-APR-15:02 | 3790.95 | 3790.95 | 7.28 | 11.80 |
May | 0.493558E+10 | 0.444202E+10 | 4327.07 | 18-MAY-15:02 | 3894.36 | 3894.36 | 7.43 | 13.21 |
June | 0.687283E+10 | 0.618555E+10 | 4412.25 | 29-JUN-18:03 | 3971.03 | 3971.03 | 7.48 | 14.43 |
July | 0.937567E+10 | 0.843810E+10 | 4544.10 | 31-JUL-18:03 | 4089.69 | 4089.69 | 7.31 | 16.29 |
August | 0.984080E+10 | 0.885672E+10 | 4542.97 | 18-AUG-15:05 | 4088.67 | 4088.67 | 6.75 | 16.27 |
September | 0.780630E+10 | 0.702567E+10 | 4782.11 | 29-SEP-15:13 | 4303.90 | 4303.90 | 6.72 | 18.69 |
October | 0.758687E+10 | 0.682819E+10 | 4535.38 | 01-OCT-15:03 | 4081.85 | 4081.85 | 7.29 | 16.17 |
November | 0.400272E+10 | 0.360245E+10 | 4408.60 | 19-NOV-11:00 | 3967.74 | 3967.74 | 6.82 | 14.38 |
December | 0.356751E+10 | 0.321076E+10 | 4146.91 | 16-DEC-16:02 | 3732.22 | 3732.22 | 7.61 | 11.14 |
Annual Sum or Average | 0.673063E+11 | 0.605757E+11 | ||||||
Minimum of Months | 0.255144E+10 | 0.229630E+10 | 4093.05 | 3683.75 | 3683.75 | 6.72 | 10.66 | |
Maximum of Months | 0.984080E+10 | 0.885672E+10 | 4782.11 | 4303.90 | 4303.90 | 7.61 | 18.69 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPUMP ELECTRIC ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRIC POWER {Maximum}[W] | PUMP ELECTRIC POWER {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.128314E+09 | 38494137.67 | 47.91 | 01-JAN-00:05 | 14.37 | 14.37 | 49.91 | 0.37 |
February | 0.115896E+09 | 34768898.54 | 47.91 | 01-FEB-00:03 | 14.37 | 14.37 | 49.57 | 0.37 |
March | 0.128314E+09 | 38494137.67 | 47.91 | 01-MAR-00:03 | 14.37 | 14.37 | 50.03 | 0.37 |
April | 0.124175E+09 | 37252391.29 | 47.91 | 01-APR-00:10 | 14.37 | 14.37 | 53.10 | 0.37 |
May | 0.128314E+09 | 38494137.67 | 47.91 | 01-MAY-00:05 | 14.37 | 14.37 | 51.77 | 0.37 |
June | 0.124175E+09 | 37252391.29 | 47.91 | 01-JUN-00:10 | 14.37 | 14.37 | 52.83 | 0.37 |
July | 0.128314E+09 | 38494137.67 | 47.91 | 01-JUL-00:10 | 14.37 | 14.37 | 53.19 | 0.37 |
August | 0.128314E+09 | 38494137.67 | 47.91 | 01-AUG-00:10 | 14.37 | 14.37 | 52.84 | 0.37 |
September | 0.124175E+09 | 37252391.29 | 47.91 | 01-SEP-00:10 | 14.37 | 14.37 | 53.14 | 0.37 |
October | 0.128314E+09 | 38494137.67 | 47.91 | 01-OCT-00:05 | 14.37 | 14.37 | 52.17 | 0.37 |
November | 0.124175E+09 | 37252391.29 | 47.91 | 01-NOV-00:10 | 14.37 | 14.37 | 53.30 | 0.37 |
December | 0.128314E+09 | 38494137.67 | 47.91 | 01-DEC-00:03 | 14.37 | 14.37 | 50.31 | 0.37 |
Annual Sum or Average | 0.151079E+10 | 0.453237E+09 | ||||||
Minimum of Months | 0.115896E+09 | 34768898.54 | 47.91 | 14.37 | 14.37 | 49.57 | 0.37 | |
Maximum of Months | 0.128314E+09 | 38494137.67 | 47.91 | 14.37 | 14.37 | 53.30 | 0.37 |
Report: PumpReportMonthly
For: COOLSYS1 PUMP
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPUMP ELECTRIC ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRIC POWER {Maximum}[W] | PUMP ELECTRIC POWER {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 0.404281E+10 | 0.363853E+10 | 1852.88 | 01-JAN-07:30 | 1667.59 | 1667.59 | 8.40 | 23.21 |
February | 0.376102E+10 | 0.338492E+10 | 1852.88 | 01-FEB-00:03 | 1667.59 | 1667.59 | 8.44 | 23.21 |
March | 0.383752E+10 | 0.345377E+10 | 1852.88 | 01-MAR-07:03 | 1667.59 | 1667.59 | 8.39 | 23.21 |
April | 0.462554E+10 | 0.416298E+10 | 1852.88 | 01-APR-06:35 | 1667.59 | 1667.59 | 8.40 | 23.21 |
May | 0.486567E+10 | 0.437910E+10 | 1852.88 | 01-MAY-00:05 | 1667.59 | 1667.59 | 9.04 | 23.21 |
June | 0.480267E+10 | 0.432241E+10 | 1852.88 | 01-JUN-00:10 | 1667.59 | 1667.59 | 8.48 | 23.21 |
July | 0.496276E+10 | 0.446649E+10 | 1852.88 | 01-JUL-00:10 | 1667.59 | 1667.59 | 9.78 | 23.21 |
August | 0.496276E+10 | 0.446649E+10 | 1852.88 | 01-AUG-00:10 | 1667.59 | 1667.59 | 10.45 | 23.21 |
September | 0.480156E+10 | 0.432141E+10 | 1852.88 | 01-SEP-00:10 | 1667.59 | 1667.59 | 9.22 | 23.21 |
October | 0.492515E+10 | 0.443263E+10 | 1852.88 | 01-OCT-00:05 | 1667.59 | 1667.59 | 10.62 | 23.21 |
November | 0.437466E+10 | 0.393719E+10 | 1852.88 | 01-NOV-00:10 | 1667.59 | 1667.59 | 8.74 | 23.21 |
December | 0.413223E+10 | 0.371900E+10 | 1852.88 | 01-DEC-00:03 | 1667.59 | 1667.59 | 8.43 | 23.21 |
Annual Sum or Average | 0.540943E+11 | 0.486849E+11 | ||||||
Minimum of Months | 0.376102E+10 | 0.338492E+10 | 1852.88 | 1667.59 | 1667.59 | 8.39 | 23.21 | |
Maximum of Months | 0.496276E+10 | 0.446649E+10 | 1852.88 | 1667.59 | 1667.59 | 10.62 | 23.21 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 49.91 | 59.94 | 24009.61 | 49050.99 | 23-JAN-07:10 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 49.57 | 58.30 | 24066.49 | 49062.35 | 13-FEB-07:10 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 50.03 | 58.81 | 23710.35 | 48878.58 | 01-MAR-07:10 |
April | 0.00 | 0.00 | 01-APR-00:10 | 53.10 | 59.50 | 23198.18 | 47894.32 | 03-APR-07:00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 51.77 | 58.04 | 22530.87 | 46913.68 | 02-MAY-06:45 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 52.83 | 58.82 | 21904.59 | 45702.28 | 02-JUN-06:10 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 53.19 | 59.10 | 21615.60 | 44771.29 | 03-JUL-06:20 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 52.84 | 58.62 | 21602.77 | 44756.39 | 31-AUG-06:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 53.14 | 59.03 | 21810.76 | 45479.17 | 29-SEP-06:15 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 52.17 | 58.90 | 22399.29 | 46652.31 | 31-OCT-06:10 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 53.30 | 59.52 | 22973.58 | 47804.62 | 30-NOV-07:15 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 50.31 | 58.94 | 23619.06 | 48671.35 | 28-DEC-07:10 |
Annual Sum or Average | 0.00 | 22779.70 | ||||||
Minimum of Months | 0.00 | 0.00 | 49.57 | 58.04 | 21602.77 | 44756.39 | ||
Maximum of Months | 0.00 | 0.00 | 53.30 | 59.94 | 24066.49 | 49062.35 |
Report: CondLoopDemandReportMonthly
For: HEATSYS1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 49.04 | 57.42 | 41629.69 | 169852.34 | 08-JAN-07:00 |
February | 0.00 | 0.00 | 01-FEB-00:03 | 43.39 | 57.22 | 35279.83 | 128646.18 | 05-FEB-06:00 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 49.10 | 57.62 | 44047.23 | 151682.65 | 30-MAR-03:00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 49.06 | 57.28 | 18819.28 | 114670.89 | 01-APR-05:00 |
May | 0.00 | 0.00 | 01-MAY-00:05 | 41.70 | 57.22 | 16856.29 | 103954.99 | 14-MAY-04:50 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 40.66 | 57.22 | 5385.66 | 70504.01 | 13-JUN-04:00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 39.85 | 57.22 | 3262.36 | 42930.66 | 11-JUL-15:05 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 39.56 | 57.22 | 2964.02 | 41888.38 | 14-AUG-08:05 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 40.81 | 57.22 | 3845.67 | 68428.22 | 20-SEP-04:00 |
October | 0.00 | 0.00 | 01-OCT-00:05 | 40.97 | 40.97 | 7942.25 | 96186.00 | 28-OCT-05:00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 41.73 | 57.22 | 27319.45 | 116248.50 | 24-NOV-04:00 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 47.01 | 57.22 | 40255.51 | 132518.10 | 24-DEC-04:00 |
Annual Sum or Average | 0.00 | 20587.99 | ||||||
Minimum of Months | 0.00 | 0.00 | 39.56 | 40.97 | 2964.02 | 41888.38 | ||
Maximum of Months | 0.00 | 0.00 | 49.10 | 57.62 | 44047.23 | 169852.34 |
Report: CondLoopDemandReportMonthly
For: COOLSYS1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum}[W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 50210.40 | 330325.98 | 14-JAN-16:01 | 10.65 | 7.26 | 0.00 | 0.00 | 01-JAN-00:05 |
February | 37016.07 | 313913.51 | 01-FEB-09:02 | 10.59 | 7.36 | 0.00 | 0.00 | 01-FEB-00:03 |
March | 32740.65 | 385326.92 | 23-MAR-15:02 | 11.40 | 7.43 | 0.00 | 0.00 | 01-MAR-00:03 |
April | 67392.05 | 372262.93 | 11-APR-15:02 | 11.11 | 7.28 | 0.00 | 0.00 | 01-APR-00:10 |
May | 69438.74 | 382239.47 | 18-MAY-15:02 | 11.36 | 7.43 | 0.00 | 0.00 | 01-MAY-00:05 |
June | 132207.42 | 466130.55 | 29-JUN-18:03 | 12.28 | 7.48 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 235954.57 | 575549.51 | 31-JUL-15:02 | 12.78 | 6.86 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 261774.54 | 602862.22 | 18-AUG-15:02 | 12.93 | 6.73 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 173235.81 | 549615.58 | 21-SEP-15:02 | 12.35 | 6.70 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 173599.25 | 529530.69 | 14-OCT-15:02 | 12.15 | 6.70 | 0.00 | 0.00 | 01-OCT-00:05 |
November | 57201.26 | 378665.90 | 19-NOV-09:02 | 10.95 | 7.06 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 55829.70 | 365123.90 | 05-DEC-09:02 | 10.81 | 7.06 | 0.00 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 112886.38 | 0.00 | ||||||
Minimum of Months | 32740.65 | 313913.51 | 10.59 | 6.70 | 0.00 | 0.00 | ||
Maximum of Months | 261774.54 | 602862.22 | 12.93 | 7.48 | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.17 | 7.56 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.17 | 7.56 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 7.56 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.17 | 7.56 |
Report: ZoneTemperatureOscillationReportMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.17 | 56.92 |
February | 0.08 | 56.92 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.17 | 56.92 |
June | 1.00 | 56.92 |
July | 1.42 | 56.92 |
August | 1.67 | 56.92 |
September | 1.00 | 56.92 |
October | 0.67 | 56.92 |
November | 0.08 | 56.92 |
December | 0.00 | 0.00 |
Annual Sum or Average | 6.25 | 56.92 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.67 | 56.92 |
Report: ZoneTemperatureOscillationReportMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.08 | 0.45 |
February | 0.00 | 0.00 |
March | 0.50 | 0.81 |
April | 1.88 | 0.81 |
May | 1.86 | 0.81 |
June | 2.96 | 0.81 |
July | 3.37 | 0.77 |
August | 3.18 | 0.77 |
September | 2.06 | 0.75 |
October | 1.90 | 0.66 |
November | 0.08 | 0.45 |
December | 0.17 | 0.30 |
Annual Sum or Average | 18.04 | 0.77 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.37 | 0.81 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.08 | 0.81 |
March | 0.25 | 0.81 |
April | 1.24 | 0.81 |
May | 1.86 | 0.81 |
June | 3.04 | 0.81 |
July | 3.15 | 0.78 |
August | 3.12 | 0.81 |
September | 1.18 | 0.81 |
October | 0.71 | 0.75 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 14.64 | 0.80 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.15 | 0.81 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.17 | 0.00 |
March | 0.00 | 0.00 |
April | 0.08 | 0.00 |
May | 0.33 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.17 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.75 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.33 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.12 | 0.80 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.12 | 0.80 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.12 | 0.80 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.58 | 0.46 |
February | 1.07 | 0.45 |
March | 0.69 | 0.38 |
April | 1.38 | 0.39 |
May | 0.97 | 0.45 |
June | 1.22 | 0.48 |
July | 3.10 | 0.52 |
August | 2.78 | 0.52 |
September | 1.21 | 0.52 |
October | 2.39 | 0.48 |
November | 0.90 | 0.44 |
December | 1.47 | 0.47 |
Annual Sum or Average | 17.76 | 0.48 |
Minimum of Months | 0.58 | 0.38 |
Maximum of Months | 3.10 | 0.52 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.08 | 0.81 |
February | 0.18 | 0.80 |
March | 0.19 | 0.56 |
April | 1.38 | 0.39 |
May | 0.97 | 0.45 |
June | 1.22 | 0.48 |
July | 3.10 | 0.52 |
August | 2.44 | 0.48 |
September | 1.24 | 0.52 |
October | 0.89 | 0.62 |
November | 0.04 | 0.80 |
December | 0.00 | 0.00 |
Annual Sum or Average | 11.74 | 0.50 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.10 | 0.81 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.08 | 0.45 |
February | 0.42 | 0.81 |
March | 0.61 | 0.78 |
April | 2.03 | 0.75 |
May | 2.31 | 0.79 |
June | 2.04 | 0.74 |
July | 1.63 | 0.59 |
August | 1.71 | 0.63 |
September | 2.69 | 0.73 |
October | 1.86 | 0.63 |
November | 0.14 | 0.59 |
December | 0.17 | 0.30 |
Annual Sum or Average | 15.68 | 0.70 |
Minimum of Months | 0.08 | 0.30 |
Maximum of Months | 2.69 | 0.81 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.50 | 0.71 |
February | 0.25 | 0.75 |
March | 0.50 | 0.76 |
April | 1.74 | 0.78 |
May | 2.33 | 0.79 |
June | 1.79 | 0.73 |
July | 1.46 | 0.56 |
August | 1.85 | 0.69 |
September | 2.19 | 0.78 |
October | 1.10 | 0.72 |
November | 0.00 | 0.00 |
December | 0.06 | 0.80 |
Annual Sum or Average | 13.76 | 0.73 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 2.33 | 0.80 |
Report: ZoneTemperatureOscillationReportMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.22 | 0.70 |
February | 1.74 | 0.65 |
March | 0.89 | 0.64 |
April | 0.94 | 0.55 |
May | 0.11 | 0.30 |
June | 0.28 | 0.50 |
July | 1.33 | 0.59 |
August | 1.83 | 0.64 |
September | 0.65 | 0.58 |
October | 2.56 | 0.66 |
November | 2.21 | 0.61 |
December | 2.03 | 0.80 |
Annual Sum or Average | 16.79 | 0.65 |
Minimum of Months | 0.11 | 0.30 |
Maximum of Months | 2.56 | 0.80 |
Report: ZoneTemperatureOscillationReportMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.42 | 114.95 |
February | 0.08 | 99.96 |
March | 0.17 | 99.96 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.25 | 99.96 |
July | 0.58 | 99.96 |
August | 0.83 | 99.96 |
September | 0.67 | 99.96 |
October | 0.75 | 116.62 |
November | 0.08 | 99.96 |
December | 0.08 | 99.96 |
Annual Sum or Average | 3.92 | 104.74 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.83 | 116.62 |
Report: ZoneTemperatureOscillationReportMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.08 | 99.96 |
February | 0.00 | 0.00 |
March | 0.08 | 99.96 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.08 | 99.96 |
Annual Sum or Average | 0.25 | 99.96 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.08 | 99.96 |
Report: ZoneTemperatureOscillationReportMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.08 | 20.01 |
Annual Sum or Average | 0.08 | 20.01 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.08 | 20.01 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: VAV WITH REHEAT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.928444E+11 | 0.00 | 0.826818E+11 | 0.376514E+11 | 0.00 | 0.00 |
February | 0.715462E+11 | 0.00 | 0.521232E+11 | 0.347166E+11 | 0.00 | 0.00 |
March | 0.990189E+11 | 0.00 | 0.546345E+11 | 0.384451E+11 | 0.00 | 0.00 |
April | 0.411572E+11 | 0.00 | 0.119133E+12 | 0.371783E+11 | 0.00 | 0.00 |
May | 0.387151E+11 | 0.00 | 0.128423E+12 | 0.383128E+11 | 0.00 | 0.00 |
June | 0.128078E+11 | 0.00 | 0.252532E+12 | 0.363829E+11 | 0.00 | 0.00 |
July | 0.871770E+10 | 0.00 | 0.484291E+12 | 0.369701E+11 | 0.00 | 0.00 |
August | 0.793534E+10 | 0.00 | 0.542108E+12 | 0.369739E+11 | 0.00 | 0.00 |
September | 0.939712E+10 | 0.00 | 0.337646E+12 | 0.358700E+11 | 0.00 | 0.00 |
October | 0.185944E+11 | 0.00 | 0.340060E+12 | 0.370379E+11 | 0.00 | 0.00 |
November | 0.594921E+11 | 0.00 | 0.907051E+11 | 0.370657E+11 | 0.00 | 0.00 |
December | 0.904185E+11 | 0.00 | 0.917404E+11 | 0.378371E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.550645E+12 | 0.00 | 0.257608E+13 | 0.444442E+12 | 0.00 | 0.00 |
Minimum of Months | 0.793534E+10 | 0.00 | 0.521232E+11 | 0.347166E+11 | 0.00 | 0.00 |
Maximum of Months | 0.990189E+11 | 0.00 | 0.542108E+12 | 0.384451E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: FLR_3_DOAS
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.116457E+11 | 0.00 | 0.112658E+11 | 0.587767E+10 | 0.00 | 0.00 |
February | 0.101732E+11 | 0.00 | 0.622464E+10 | 0.530887E+10 | 0.00 | 0.00 |
March | 0.132557E+11 | 0.00 | 0.716323E+10 | 0.587767E+10 | 0.00 | 0.00 |
April | 0.686313E+10 | 0.00 | 0.167384E+11 | 0.568807E+10 | 0.00 | 0.00 |
May | 0.577283E+10 | 0.00 | 0.173875E+11 | 0.587767E+10 | 0.00 | 0.00 |
June | 0.108118E+10 | 0.00 | 0.349109E+11 | 0.568807E+10 | 0.00 | 0.00 |
July | 62613326.23 | 0.00 | 0.710409E+11 | 0.587767E+10 | 0.00 | 0.00 |
August | 29986387.10 | 0.00 | 0.800063E+11 | 0.587767E+10 | 0.00 | 0.00 |
September | 0.541140E+09 | 0.00 | 0.471891E+11 | 0.568807E+10 | 0.00 | 0.00 |
October | 0.229530E+10 | 0.00 | 0.517453E+11 | 0.587767E+10 | 0.00 | 0.00 |
November | 0.868603E+10 | 0.00 | 0.115868E+11 | 0.568807E+10 | 0.00 | 0.00 |
December | 0.116436E+11 | 0.00 | 0.131181E+11 | 0.587767E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.720504E+11 | 0.00 | 0.368377E+12 | 0.692049E+11 | 0.00 | 0.00 |
Minimum of Months | 29986387.10 | 0.00 | 0.622464E+10 | 0.530887E+10 | 0.00 | 0.00 |
Maximum of Months | 0.132557E+11 | 0.00 | 0.800063E+11 | 0.587767E+10 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: VAV WITH REHEAT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.376514E+11 | 0.826818E+11 | 0.928444E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.347166E+11 | 0.521232E+11 | 0.715462E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.384451E+11 | 0.546345E+11 | 0.990189E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.371783E+11 | 0.119133E+12 | 0.411572E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.383128E+11 | 0.128423E+12 | 0.387151E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.363829E+11 | 0.252532E+12 | 0.128078E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.369701E+11 | 0.484291E+12 | 0.871770E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.369739E+11 | 0.542108E+12 | 0.793534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.358700E+11 | 0.337646E+12 | 0.939712E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.370379E+11 | 0.340060E+12 | 0.185944E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.370657E+11 | 0.907051E+11 | 0.594921E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.378371E+11 | 0.917404E+11 | 0.904185E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.444442E+12 | 0.257608E+13 | 0.550645E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.347166E+11 | 0.521232E+11 | 0.793534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.384451E+11 | 0.542108E+12 | 0.990189E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: FLR_3_DOAS
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.587767E+10 | 0.112658E+11 | 0.116457E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.530887E+10 | 0.622464E+10 | 0.101732E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.587767E+10 | 0.716323E+10 | 0.132557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.568807E+10 | 0.167384E+11 | 0.686313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.587767E+10 | 0.173875E+11 | 0.577283E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.568807E+10 | 0.349109E+11 | 0.108118E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.587767E+10 | 0.710409E+11 | 62613326.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.587767E+10 | 0.800063E+11 | 29986387.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.568807E+10 | 0.471891E+11 | 0.541140E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.587767E+10 | 0.517453E+11 | 0.229530E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.568807E+10 | 0.115868E+11 | 0.868603E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.587767E+10 | 0.131181E+11 | 0.116436E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.692049E+11 | 0.368377E+12 | 0.720504E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.530887E+10 | 0.622464E+10 | 29986387.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.587767E+10 | 0.800063E+11 | 0.132557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: VAV WITH REHEAT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.376514E+11 | 0.928444E+11 | 0.826818E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.347166E+11 | 0.715462E+11 | 0.521232E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.384451E+11 | 0.990189E+11 | 0.546345E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.371783E+11 | 0.411572E+11 | 0.119133E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.383128E+11 | 0.387151E+11 | 0.128423E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.363829E+11 | 0.128078E+11 | 0.252532E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.369701E+11 | 0.871770E+10 | 0.484291E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.369739E+11 | 0.793534E+10 | 0.542108E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.358700E+11 | 0.939712E+10 | 0.337646E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.370379E+11 | 0.185944E+11 | 0.340060E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.370657E+11 | 0.594921E+11 | 0.907051E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.378371E+11 | 0.904185E+11 | 0.917404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.444442E+12 | 0.550645E+12 | 0.257608E+13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.347166E+11 | 0.793534E+10 | 0.521232E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.384451E+11 | 0.990189E+11 | 0.542108E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: FLR_3_DOAS
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.587767E+10 | 0.116457E+11 | 0.112658E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.530887E+10 | 0.101732E+11 | 0.622464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.587767E+10 | 0.132557E+11 | 0.716323E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.568807E+10 | 0.686313E+10 | 0.167384E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.587767E+10 | 0.577283E+10 | 0.173875E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.568807E+10 | 0.108118E+10 | 0.349109E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.587767E+10 | 62613326.23 | 0.710409E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.587767E+10 | 29986387.10 | 0.800063E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.568807E+10 | 0.541140E+09 | 0.471891E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.587767E+10 | 0.229530E+10 | 0.517453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.568807E+10 | 0.868603E+10 | 0.115868E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.587767E+10 | 0.116436E+11 | 0.131181E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.692049E+11 | 0.720504E+11 | 0.368377E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.530887E+10 | 29986387.10 | 0.622464E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.587767E+10 | 0.132557E+11 | 0.800063E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BASEMENT
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.518989E+11 | 0.00 | 0.00 | 56913.38 | 0.233639E+09 | 0.00 | 0.593381E+09 | 0.00 | 1.05 |
February | 0.470472E+11 | 0.00 | 0.00 | 0.00 | 45557123.94 | 0.00 | 0.00 | 0.00 | 1.05 |
March | 0.541981E+11 | 0.00 | 0.00 | 0.00 | 0.130599E+09 | 0.00 | 0.00 | 0.00 | 1.05 |
April | 0.408841E+11 | 0.00 | 0.00 | 0.00 | 0.430986E+09 | 0.00 | 0.00 | 0.00 | 1.05 |
May | 0.408997E+11 | 0.00 | 0.00 | 0.00 | 93604548.71 | 0.00 | 0.00 | 0.00 | 1.05 |
June | 0.270929E+11 | 0.00 | 0.00 | 0.00 | 0.254361E+10 | 0.00 | 0.00 | 0.00 | 1.05 |
July | 0.129735E+11 | 0.00 | 0.00 | 0.00 | 0.106161E+11 | 0.00 | 0.00 | 0.00 | 1.06 |
August | 0.964934E+10 | 0.00 | 0.00 | 0.00 | 0.132495E+11 | 0.00 | 0.00 | 0.00 | 1.06 |
September | 0.212506E+11 | 0.00 | 0.00 | 0.00 | 0.494870E+10 | 0.00 | 0.00 | 0.00 | 1.06 |
October | 0.260282E+11 | 0.00 | 0.00 | 0.00 | 0.669519E+10 | 0.00 | 0.00 | 0.00 | 1.06 |
November | 0.417338E+11 | 0.00 | 0.00 | 1145288.60 | 0.135071E+09 | 0.00 | 0.491295E+10 | 0.00 | 1.05 |
December | 0.505860E+11 | 0.00 | 0.00 | 133472.38 | 0.116658E+09 | 0.00 | 0.766720E+09 | 0.00 | 1.05 |
Annual Sum or Average | 0.424242E+12 | 0.00 | 0.00 | 1335674.36 | 0.392392E+11 | 0.00 | 0.627305E+10 | 0.00 | 1.05 |
Minimum of Months | 0.964934E+10 | 0.00 | 0.00 | 0.00 | 45557123.94 | 0.00 | 0.00 | 0.00 | 1.05 |
Maximum of Months | 0.541981E+11 | 0.00 | 0.00 | 1145288.60 | 0.132495E+11 | 0.00 | 0.491295E+10 | 0.00 | 1.06 |
Report: MechanicalVentilationLoadsMonthly
For: RETAIL_1_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.591712E+10 | 19013092.37 | 0.00 | 908925.50 | 11935202.35 | 0.141348E+09 | 0.463112E+09 | 0.00 | 2.37 |
February | 0.561439E+10 | 4604647.50 | 0.00 | 417519.88 | 1049129.38 | 0.00 | 0.224397E+09 | 0.00 | 2.37 |
March | 0.647888E+10 | 3061979.51 | 0.00 | 35421.21 | 13145774.74 | 0.230492E+09 | 16737886.97 | 0.00 | 2.37 |
April | 0.506973E+10 | 0.00 | 0.00 | 0.00 | 53486671.36 | 4099991.74 | 0.00 | 0.00 | 2.37 |
May | 0.507577E+10 | 0.00 | 0.00 | 0.00 | 11616607.62 | 0.00 | 0.00 | 0.00 | 2.37 |
June | 0.336232E+10 | 0.00 | 0.00 | 0.00 | 0.315669E+09 | 0.00 | 0.00 | 0.00 | 2.37 |
July | 0.161005E+10 | 0.00 | 0.00 | 0.00 | 0.131749E+10 | 0.00 | 0.00 | 0.00 | 2.38 |
August | 0.119751E+10 | 0.00 | 0.00 | 0.00 | 0.164430E+10 | 0.00 | 0.00 | 0.00 | 2.38 |
September | 0.263139E+10 | 0.130457E+09 | 0.00 | 13353.62 | 0.492658E+09 | 0.00 | 5861563.12 | 0.00 | 2.39 |
October | 0.314325E+10 | 0.399007E+09 | 0.00 | 282805.17 | 0.487165E+09 | 0.00 | 86905108.34 | 0.00 | 2.41 |
November | 0.543214E+10 | 19155240.36 | 0.00 | 996846.77 | 600760.78 | 0.00 | 0.364164E+09 | 0.00 | 2.38 |
December | 0.596417E+10 | 15564828.03 | 0.00 | 1405956.19 | 926566.81 | 6905397.15 | 0.412440E+09 | 0.00 | 2.38 |
Annual Sum or Average | 0.514967E+11 | 0.590864E+09 | 0.00 | 4060828.35 | 0.435005E+10 | 0.382846E+09 | 0.157362E+10 | 0.00 | 2.38 |
Minimum of Months | 0.119751E+10 | 0.00 | 0.00 | 0.00 | 600760.78 | 0.00 | 0.00 | 0.00 | 2.37 |
Maximum of Months | 0.647888E+10 | 0.399007E+09 | 0.00 | 1405956.19 | 0.164430E+10 | 0.230492E+09 | 0.463112E+09 | 0.00 | 2.41 |
Report: MechanicalVentilationLoadsMonthly
For: RETAIL_2_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.493851E+10 | 0.00 | 0.00 | 19559.39 | 22774109.98 | 0.00 | 0.178208E+09 | 0.00 | 1.60 |
February | 0.432855E+10 | 0.00 | 0.00 | 57440.36 | 4440717.92 | 0.00 | 0.257359E+09 | 0.00 | 1.61 |
March | 0.515236E+10 | 0.00 | 0.00 | 21985.26 | 12730262.66 | 0.00 | 0.130620E+09 | 0.00 | 1.61 |
April | 0.378380E+10 | 0.00 | 0.00 | 29651.65 | 42010716.90 | 0.00 | 0.201376E+09 | 0.00 | 1.61 |
May | 0.388753E+10 | 0.00 | 0.00 | 6335.10 | 9124179.94 | 0.00 | 99185907.97 | 0.00 | 1.61 |
June | 0.258835E+10 | 0.00 | 0.00 | 6212.43 | 0.247940E+09 | 0.00 | 52553184.69 | 0.00 | 1.62 |
July | 0.123111E+10 | 2373613.35 | 0.00 | 6514.57 | 0.103244E+10 | 0.00 | 33486346.15 | 0.00 | 1.62 |
August | 0.853636E+09 | 2364529.74 | 0.00 | 16285.11 | 0.128914E+10 | 0.00 | 86925776.84 | 0.00 | 1.62 |
September | 0.191157E+10 | 3135483.07 | 0.00 | 54484.10 | 0.479243E+09 | 0.00 | 0.159795E+09 | 0.00 | 1.62 |
October | 0.227984E+10 | 268972.66 | 0.00 | 147275.58 | 0.652350E+09 | 0.00 | 0.257131E+09 | 0.00 | 1.61 |
November | 0.415189E+10 | 0.00 | 0.00 | 94573.73 | 13166185.61 | 0.00 | 0.395062E+09 | 0.00 | 1.61 |
December | 0.472275E+10 | 0.00 | 0.00 | 54438.75 | 11371318.96 | 0.00 | 0.282855E+09 | 0.00 | 1.60 |
Annual Sum or Average | 0.398299E+11 | 8142598.81 | 0.00 | 514756.03 | 0.381673E+10 | 0.00 | 0.213456E+10 | 0.00 | 1.61 |
Minimum of Months | 0.853636E+09 | 0.00 | 0.00 | 6212.43 | 4440717.92 | 0.00 | 33486346.15 | 0.00 | 1.60 |
Maximum of Months | 0.515236E+10 | 3135483.07 | 0.00 | 147275.58 | 0.128914E+10 | 0.00 | 0.395062E+09 | 0.00 | 1.62 |
Report: MechanicalVentilationLoadsMonthly
For: MECH_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.468132E+10 | 0.00 | 0.00 | 0.00 | 20900419.34 | 14446819.56 | 0.00 | 0.00 | 0.69 |
February | 0.420867E+10 | 0.00 | 0.00 | 0.00 | 4075367.46 | 0.00 | 0.00 | 0.00 | 0.70 |
March | 0.482081E+10 | 0.00 | 0.00 | 0.00 | 11682907.83 | 27549941.94 | 0.00 | 0.00 | 0.70 |
April | 0.365733E+10 | 0.00 | 0.00 | 0.00 | 38554376.03 | 0.00 | 0.00 | 0.00 | 0.70 |
May | 0.365873E+10 | 0.00 | 0.00 | 0.00 | 8373507.77 | 0.00 | 0.00 | 0.00 | 0.70 |
June | 0.242363E+10 | 0.00 | 0.00 | 0.00 | 0.227541E+09 | 0.00 | 0.00 | 0.00 | 0.70 |
July | 0.116056E+10 | 0.00 | 0.00 | 0.00 | 0.949679E+09 | 0.00 | 0.00 | 0.00 | 0.70 |
August | 0.863194E+09 | 0.00 | 0.00 | 0.00 | 0.118525E+10 | 0.00 | 0.00 | 0.00 | 0.70 |
September | 0.190100E+10 | 0.00 | 0.00 | 0.00 | 0.442692E+09 | 0.00 | 0.00 | 0.00 | 0.70 |
October | 0.232838E+10 | 0.00 | 0.00 | 0.00 | 0.598926E+09 | 0.00 | 0.00 | 0.00 | 0.70 |
November | 0.417294E+10 | 0.00 | 0.00 | 0.00 | 12082966.17 | 0.00 | 0.00 | 0.00 | 0.69 |
December | 0.459383E+10 | 0.00 | 0.00 | 0.00 | 10435768.28 | 0.00 | 0.00 | 0.00 | 0.69 |
Annual Sum or Average | 0.384704E+11 | 0.00 | 0.00 | 0.00 | 0.351019E+10 | 41996761.50 | 0.00 | 0.00 | 0.70 |
Minimum of Months | 0.863194E+09 | 0.00 | 0.00 | 0.00 | 4075367.46 | 0.00 | 0.00 | 0.00 | 0.69 |
Maximum of Months | 0.482081E+10 | 0.00 | 0.00 | 0.00 | 0.118525E+10 | 27549941.94 | 0.00 | 0.00 | 0.70 |
Report: MechanicalVentilationLoadsMonthly
For: STORAGE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.213620E+10 | 0.00 | 0.00 | 0.00 | 9671095.40 | 36640220.92 | 0.00 | 0.00 | 0.55 |
February | 0.194745E+10 | 0.00 | 0.00 | 0.00 | 1885764.43 | 0.00 | 0.00 | 0.00 | 0.56 |
March | 0.221890E+10 | 0.00 | 0.00 | 0.00 | 5405944.94 | 24540946.61 | 0.00 | 0.00 | 0.56 |
April | 0.169233E+10 | 0.00 | 0.00 | 0.00 | 17839979.32 | 0.00 | 0.00 | 0.00 | 0.56 |
May | 0.169298E+10 | 0.00 | 0.00 | 0.00 | 3874610.90 | 0.00 | 0.00 | 0.00 | 0.56 |
June | 0.112147E+10 | 0.00 | 0.00 | 0.00 | 0.105289E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
July | 0.537016E+09 | 0.00 | 0.00 | 0.00 | 0.439438E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
August | 0.399419E+09 | 0.00 | 0.00 | 0.00 | 0.548442E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
September | 0.879637E+09 | 0.00 | 0.00 | 0.00 | 0.204844E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
October | 0.107739E+10 | 0.00 | 0.00 | 0.00 | 0.277137E+09 | 0.00 | 0.00 | 0.00 | 0.56 |
November | 0.193092E+10 | 0.00 | 0.00 | 0.00 | 5591060.96 | 0.00 | 0.00 | 0.00 | 0.56 |
December | 0.212567E+10 | 0.00 | 0.00 | 0.00 | 4828865.35 | 0.00 | 0.00 | 0.00 | 0.55 |
Annual Sum or Average | 0.177594E+11 | 0.00 | 0.00 | 0.00 | 0.162425E+10 | 61181167.53 | 0.00 | 0.00 | 0.56 |
Minimum of Months | 0.399419E+09 | 0.00 | 0.00 | 0.00 | 1885764.43 | 0.00 | 0.00 | 0.00 | 0.55 |
Maximum of Months | 0.221890E+10 | 0.00 | 0.00 | 0.00 | 0.548442E+09 | 36640220.92 | 0.00 | 0.00 | 0.56 |
Report: MechanicalVentilationLoadsMonthly
For: LAUNDRY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.158060E+10 | 0.320957E+09 | 0.00 | 78164623.51 | 6671101.01 | 0.00 | 0.793773E+11 | 0.00 | 24.82 |
February | 0.582891E+09 | 62391816.79 | 0.00 | 72514509.57 | 1492237.41 | 0.00 | 0.724864E+11 | 0.00 | 25.17 |
March | 0.848045E+09 | 0.175180E+09 | 0.00 | 78769704.46 | 7957031.95 | 0.00 | 0.833128E+11 | 0.00 | 25.22 |
April | 0.331029E+09 | 0.590172E+09 | 0.00 | 77797708.91 | 14193148.87 | 0.00 | 0.630360E+11 | 0.00 | 25.02 |
May | 0.341136E+09 | 0.130036E+09 | 0.00 | 82315772.46 | 1224631.32 | 0.00 | 0.628763E+11 | 0.00 | 24.97 |
June | 0.202520E+09 | 0.349209E+10 | 0.00 | 71637056.58 | 81447391.80 | 0.00 | 0.413428E+11 | 0.00 | 24.74 |
July | 64328900.29 | 0.146868E+11 | 0.00 | 49159424.85 | 0.423500E+09 | 0.00 | 0.194157E+11 | 0.00 | 24.46 |
August | 54511110.32 | 0.180779E+11 | 0.00 | 43700289.99 | 0.678505E+09 | 0.00 | 0.146282E+11 | 0.00 | 24.55 |
September | 0.159467E+09 | 0.678408E+10 | 0.00 | 62791275.31 | 0.207852E+09 | 0.00 | 0.322376E+11 | 0.00 | 24.68 |
October | 0.229743E+09 | 0.927317E+10 | 0.00 | 59992632.06 | 0.282457E+09 | 0.00 | 0.393822E+11 | 0.00 | 24.54 |
November | 0.552443E+09 | 0.185816E+09 | 0.00 | 77351056.94 | 3592049.46 | 0.00 | 0.719101E+11 | 0.00 | 25.04 |
December | 0.640628E+09 | 0.155728E+09 | 0.00 | 79463583.18 | 7859913.51 | 0.00 | 0.790012E+11 | 0.00 | 24.90 |
Annual Sum or Average | 0.558734E+10 | 0.539343E+11 | 0.00 | 0.833658E+09 | 0.171675E+10 | 0.00 | 0.659007E+12 | 0.00 | 24.84 |
Minimum of Months | 54511110.32 | 62391816.79 | 0.00 | 43700289.99 | 1224631.32 | 0.00 | 0.146282E+11 | 0.00 | 24.46 |
Maximum of Months | 0.158060E+10 | 0.180779E+11 | 0.00 | 82315772.46 | 0.678505E+09 | 0.00 | 0.833128E+11 | 0.00 | 25.22 |
Report: MechanicalVentilationLoadsMonthly
For: CAFE_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.125271E+11 | 89298053.84 | 0.00 | 9998979.56 | 40918643.42 | 0.00 | 0.158693E+11 | 0.00 | 3.67 |
February | 0.110316E+11 | 20272047.93 | 0.00 | 7761415.09 | 4352292.82 | 0.00 | 0.143918E+11 | 0.00 | 3.68 |
March | 0.182276E+11 | 60449299.46 | 0.00 | 3993801.83 | 10141612.06 | 0.00 | 0.110634E+11 | 0.00 | 3.68 |
April | 0.105921E+11 | 12761181.85 | 0.00 | 4375270.22 | 0.220194E+09 | 0.00 | 0.115020E+11 | 0.00 | 3.68 |
May | 0.114039E+11 | 0.00 | 0.00 | 3536788.31 | 50594728.21 | 0.00 | 0.106994E+11 | 0.00 | 3.68 |
June | 0.605535E+10 | 3537286.75 | 0.00 | 4259982.92 | 0.137132E+10 | 0.00 | 0.858456E+10 | 0.00 | 3.69 |
July | 0.239467E+10 | 0.212786E+09 | 0.00 | 4515127.30 | 0.552540E+10 | 0.00 | 0.461317E+10 | 0.00 | 3.69 |
August | 0.116559E+10 | 0.322125E+09 | 0.00 | 5453431.04 | 0.683944E+10 | 0.00 | 0.404458E+10 | 0.00 | 3.70 |
September | 0.393734E+10 | 0.992728E+09 | 0.00 | 6635262.73 | 0.168657E+10 | 0.00 | 0.754242E+10 | 0.00 | 3.70 |
October | 0.382663E+10 | 0.226705E+10 | 0.00 | 9796474.30 | 0.143508E+10 | 0.00 | 0.102365E+11 | 0.00 | 3.71 |
November | 0.726453E+10 | 79705862.09 | 0.00 | 12670294.37 | 1273932.14 | 0.00 | 0.179735E+11 | 0.00 | 3.69 |
December | 0.108859E+11 | 64110180.92 | 0.00 | 13548519.86 | 2046870.76 | 0.00 | 0.169012E+11 | 0.00 | 3.68 |
Annual Sum or Average | 0.993123E+11 | 0.412483E+10 | 0.00 | 86545347.52 | 0.171873E+11 | 0.00 | 0.133422E+12 | 0.00 | 3.69 |
Minimum of Months | 0.116559E+10 | 0.00 | 0.00 | 3536788.31 | 1273932.14 | 0.00 | 0.404458E+10 | 0.00 | 3.67 |
Maximum of Months | 0.182276E+11 | 0.226705E+10 | 0.00 | 13548519.86 | 0.683944E+10 | 0.00 | 0.179735E+11 | 0.00 | 3.71 |
Report: MechanicalVentilationLoadsMonthly
For: LOBBY_FLR_1
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.735318E+11 | 0.00 | 0.00 | 9059495.15 | 0.444857E+09 | 0.00 | 0.264066E+11 | 0.00 | 1.86 |
February | 0.581922E+11 | 0.00 | 0.00 | 11441949.96 | 86742504.94 | 0.00 | 0.313981E+11 | 0.00 | 1.87 |
March | 0.779891E+11 | 0.00 | 0.00 | 7578340.36 | 0.248666E+09 | 0.00 | 0.251986E+11 | 0.00 | 1.87 |
April | 0.497722E+11 | 0.00 | 0.00 | 8377908.44 | 0.820614E+09 | 0.00 | 0.280642E+11 | 0.00 | 1.87 |
May | 0.558313E+11 | 0.00 | 0.00 | 6339842.95 | 0.178227E+09 | 0.00 | 0.220368E+11 | 0.00 | 1.87 |
June | 0.369216E+11 | 0.00 | 0.00 | 5790389.56 | 0.484312E+10 | 0.00 | 0.146587E+11 | 0.00 | 1.88 |
July | 0.178414E+11 | 0.259301E+09 | 0.00 | 4788062.94 | 0.199542E+11 | 0.00 | 0.685575E+10 | 0.00 | 1.88 |
August | 0.109343E+11 | 0.269649E+09 | 0.00 | 5997154.10 | 0.249579E+11 | 0.00 | 0.743245E+10 | 0.00 | 1.88 |
September | 0.241340E+11 | 0.332196E+09 | 0.00 | 8936172.94 | 0.909032E+10 | 0.00 | 0.163191E+11 | 0.00 | 1.88 |
October | 0.237601E+11 | 0.100015E+10 | 0.00 | 15033422.34 | 0.117477E+11 | 0.00 | 0.257899E+11 | 0.00 | 1.88 |
November | 0.467851E+11 | 32868109.44 | 0.00 | 17542806.23 | 0.224313E+09 | 0.00 | 0.420420E+11 | 0.00 | 1.87 |
December | 0.641325E+11 | 0.00 | 0.00 | 12727214.22 | 0.222121E+09 | 0.00 | 0.336400E+11 | 0.00 | 1.86 |
Annual Sum or Average | 0.539826E+12 | 0.189416E+10 | 0.00 | 0.113613E+09 | 0.728188E+11 | 0.00 | 0.279842E+12 | 0.00 | 1.87 |
Minimum of Months | 0.109343E+11 | 0.00 | 0.00 | 4788062.94 | 86742504.94 | 0.00 | 0.685575E+10 | 0.00 | 1.86 |
Maximum of Months | 0.779891E+11 | 0.100015E+10 | 0.00 | 17542806.23 | 0.249579E+11 | 0.00 | 0.420420E+11 | 0.00 | 1.88 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_1_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.264135E+09 | 11578701.34 | 0.00 | 4488859.82 | 5691327.29 | 0.754600E+09 | 0.103068E+10 | 0.00 | 0.47 |
February | 0.304539E+09 | 3556618.46 | 0.00 | 3999467.17 | 807626.10 | 0.541255E+09 | 0.970614E+09 | 0.00 | 0.47 |
March | 0.378082E+09 | 4414199.78 | 0.00 | 3923416.27 | 3539177.36 | 0.741910E+09 | 0.974696E+09 | 0.00 | 0.47 |
April | 0.209621E+09 | 8659858.78 | 0.00 | 6812156.42 | 13234033.91 | 0.140970E+09 | 0.113375E+10 | 1699.48 | 0.47 |
May | 0.201352E+09 | 2111826.67 | 0.00 | 7075759.45 | 5298354.94 | 0.122775E+09 | 0.110180E+10 | 0.00 | 0.47 |
June | 96483198.24 | 56736659.56 | 0.00 | 6953563.62 | 55647939.46 | 6845240.52 | 0.722455E+09 | 0.00 | 0.48 |
July | 21857007.14 | 0.282330E+09 | 81276.33 | 4999154.42 | 0.141928E+09 | 375698.69 | 0.329219E+09 | 5814.93 | 0.48 |
August | 19754246.77 | 0.374822E+09 | 149355.07 | 4427673.47 | 0.153131E+09 | 343769.09 | 0.259993E+09 | 5709.62 | 0.48 |
September | 79137335.50 | 0.153875E+09 | 139783.39 | 6109317.65 | 55504596.13 | 1122097.01 | 0.630194E+09 | 5516.25 | 0.48 |
October | 91459842.09 | 0.271681E+09 | 550068.38 | 4997613.16 | 61705309.28 | 67469478.69 | 0.760853E+09 | 18001.85 | 0.48 |
November | 0.234561E+09 | 11186397.32 | 2332.51 | 5508199.92 | 2520162.42 | 0.387847E+09 | 0.115123E+10 | 2353.96 | 0.47 |
December | 0.269893E+09 | 11245811.32 | 6044.32 | 5001184.41 | 2718170.79 | 0.707340E+09 | 0.101118E+10 | 1045.99 | 0.47 |
Annual Sum or Average | 0.217088E+10 | 0.119220E+10 | 928860.00 | 64296365.77 | 0.501726E+09 | 0.347285E+10 | 0.100767E+11 | 40142.09 | 0.47 |
Minimum of Months | 19754246.77 | 2111826.67 | 0.00 | 3923416.27 | 807626.10 | 343769.09 | 0.259993E+09 | 0.00 | 0.47 |
Maximum of Months | 0.378082E+09 | 0.374822E+09 | 550068.38 | 7075759.45 | 0.153131E+09 | 0.754600E+09 | 0.115123E+10 | 18001.85 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_2_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.338632E+09 | 4341156.67 | 4050.84 | 1521506.23 | 12921105.50 | 0.118395E+10 | 0.529800E+09 | 3715.63 | 0.47 |
February | 0.342329E+09 | 925797.61 | 0.00 | 1887931.08 | 3438446.96 | 0.863788E+09 | 0.612402E+09 | 0.00 | 0.47 |
March | 0.401272E+09 | 2430351.49 | 0.00 | 2469457.09 | 5523025.65 | 0.951310E+09 | 0.743561E+09 | 0.00 | 0.47 |
April | 0.222611E+09 | 7034619.43 | 0.00 | 5762951.82 | 14859273.26 | 0.193430E+09 | 0.106935E+10 | 1699.48 | 0.47 |
May | 0.201883E+09 | 1894719.59 | 0.00 | 6923936.20 | 5515462.02 | 0.126634E+09 | 0.109756E+10 | 0.00 | 0.47 |
June | 96133246.21 | 55640321.44 | 0.00 | 7076679.43 | 56744277.59 | 7747206.81 | 0.721780E+09 | 0.00 | 0.48 |
July | 21807865.83 | 0.272286E+09 | 72977.89 | 5029085.58 | 0.151980E+09 | 360220.74 | 0.329254E+09 | 5835.06 | 0.48 |
August | 20593167.49 | 0.329284E+09 | 190215.98 | 4097415.04 | 0.198628E+09 | 447627.06 | 0.259381E+09 | 5980.02 | 0.48 |
September | 83638491.41 | 0.123830E+09 | 154550.43 | 5018284.46 | 85534222.34 | 1271952.73 | 0.626634E+09 | 6811.28 | 0.48 |
October | 98240179.76 | 0.220544E+09 | 573163.52 | 3356373.93 | 0.112821E+09 | 0.140477E+09 | 0.682707E+09 | 15341.45 | 0.48 |
November | 0.287846E+09 | 5390815.76 | 0.00 | 2356336.88 | 8317706.43 | 0.699163E+09 | 0.789784E+09 | 2724.02 | 0.47 |
December | 0.318021E+09 | 4463483.55 | 3317.94 | 1692549.55 | 9502583.74 | 0.111026E+10 | 0.563439E+09 | 1687.18 | 0.47 |
Annual Sum or Average | 0.243301E+10 | 0.102806E+10 | 998276.60 | 47192507.29 | 0.665785E+09 | 0.527884E+10 | 0.802565E+10 | 43794.11 | 0.47 |
Minimum of Months | 20593167.49 | 925797.61 | 0.00 | 1521506.23 | 3438446.96 | 360220.74 | 0.259381E+09 | 0.00 | 0.47 |
Maximum of Months | 0.401272E+09 | 0.329284E+09 | 573163.52 | 7076679.43 | 0.198628E+09 | 0.118395E+10 | 0.109756E+10 | 15341.45 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_3_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.157102E+11 | 0.233858E+09 | 0.00 | 57924105.58 | 282023.52 | 0.00 | 0.120778E+11 | 0.00 | 0.54 |
February | 0.156554E+11 | 59168646.43 | 0.00 | 38846800.32 | 0.00 | 0.00 | 0.898607E+10 | 0.00 | 0.54 |
March | 0.226786E+11 | 0.107829E+09 | 0.00 | 15829408.44 | 0.00 | 0.00 | 0.575772E+10 | 0.00 | 0.54 |
April | 0.163664E+11 | 0.150050E+09 | 0.00 | 9515063.34 | 0.146801E+09 | 0.00 | 0.384052E+10 | 0.00 | 0.54 |
May | 0.191430E+11 | 25856310.25 | 0.00 | 574962.09 | 74607907.32 | 0.00 | 0.284559E+09 | 0.00 | 0.54 |
June | 0.112873E+11 | 8332136.91 | 0.00 | 764.36 | 0.151533E+10 | 0.00 | 2590196.94 | 0.00 | 0.54 |
July | 0.474312E+10 | 0.388455E+10 | 0.00 | 404095.04 | 0.186854E+10 | 0.00 | 89086414.04 | 0.00 | 0.54 |
August | 0.298972E+10 | 0.667363E+10 | 0.00 | 3445657.46 | 0.486239E+09 | 0.00 | 0.864228E+09 | 0.00 | 0.54 |
September | 0.626258E+10 | 0.264798E+10 | 0.00 | 16255498.54 | 0.192682E+09 | 0.00 | 0.343603E+10 | 0.00 | 0.54 |
October | 0.637428E+10 | 0.436759E+10 | 0.00 | 31807781.34 | 0.160024E+09 | 0.00 | 0.613171E+10 | 0.00 | 0.54 |
November | 0.114948E+11 | 0.185891E+09 | 0.00 | 60450649.87 | 0.00 | 0.00 | 0.125657E+11 | 0.00 | 0.54 |
December | 0.138839E+11 | 0.189414E+09 | 0.00 | 66104579.36 | 0.00 | 0.00 | 0.130759E+11 | 0.00 | 0.54 |
Annual Sum or Average | 0.146589E+12 | 0.185341E+11 | 0.00 | 0.301159E+09 | 0.444451E+10 | 0.00 | 0.671119E+11 | 0.00 | 0.54 |
Minimum of Months | 0.298972E+10 | 8332136.91 | 0.00 | 764.36 | 0.00 | 0.00 | 2590196.94 | 0.00 | 0.54 |
Maximum of Months | 0.226786E+11 | 0.667363E+10 | 0.00 | 66104579.36 | 0.186854E+10 | 0.00 | 0.130759E+11 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_4_MULT19_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.464639E+10 | 24033863.35 | 23766.69 | 35929036.14 | 0.210070E+09 | 0.458306E+09 | 0.227053E+11 | 12146.33 | 0.53 |
February | 0.480532E+10 | 9590854.27 | 90657.51 | 36935405.51 | 49478747.61 | 0.140477E+09 | 0.196976E+11 | 8387.04 | 0.54 |
March | 0.555918E+10 | 19123240.11 | 0.00 | 42827045.92 | 88705400.71 | 0.271523E+09 | 0.225786E+11 | 0.00 | 0.54 |
April | 0.335947E+10 | 59531003.15 | 267851.73 | 57134277.24 | 0.237040E+09 | 51367270.67 | 0.167484E+11 | 13092.01 | 0.54 |
May | 0.306770E+10 | 8387103.52 | 64332.47 | 67357946.06 | 92010990.26 | 42054464.79 | 0.162510E+11 | 1791.32 | 0.54 |
June | 0.150052E+10 | 0.485456E+09 | 1392565.14 | 68312006.26 | 0.103679E+10 | 10578244.04 | 0.971050E+10 | 29388.19 | 0.54 |
July | 0.366673E+09 | 0.229224E+10 | 4984264.80 | 50024556.41 | 0.345576E+10 | 1478322.01 | 0.441444E+10 | 106121.00 | 0.54 |
August | 0.306744E+09 | 0.290230E+10 | 9256817.97 | 42830018.93 | 0.424820E+10 | 3203013.96 | 0.350461E+10 | 120699.14 | 0.54 |
September | 0.122021E+10 | 0.102223E+10 | 2929634.52 | 51288654.46 | 0.181545E+10 | 13321302.32 | 0.843004E+10 | 51373.00 | 0.54 |
October | 0.139648E+10 | 0.209408E+10 | 4835186.95 | 44060512.32 | 0.242866E+10 | 13675700.91 | 0.110836E+11 | 41268.79 | 0.54 |
November | 0.411695E+10 | 26513682.31 | 7312.04 | 41001025.76 | 0.159365E+09 | 0.165581E+09 | 0.197974E+11 | 5100.34 | 0.54 |
December | 0.437999E+10 | 50976443.56 | 90350.84 | 35693518.41 | 0.138342E+09 | 0.122595E+09 | 0.224876E+11 | 5776.61 | 0.53 |
Annual Sum or Average | 0.347256E+11 | 0.899446E+10 | 23942740.66 | 0.573394E+09 | 0.139599E+11 | 0.129416E+10 | 0.177409E+12 | 395143.77 | 0.54 |
Minimum of Months | 0.306744E+09 | 8387103.52 | 0.00 | 35693518.41 | 49478747.61 | 1478322.01 | 0.350461E+10 | 0.00 | 0.53 |
Maximum of Months | 0.555918E+10 | 0.290230E+10 | 9256817.97 | 68312006.26 | 0.424820E+10 | 0.458306E+09 | 0.227053E+11 | 120699.14 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_5_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.281617E+09 | 11819108.18 | 0.00 | 5130532.39 | 5450920.45 | 0.726916E+09 | 0.104024E+10 | 0.00 | 0.47 |
February | 0.308520E+09 | 3788785.06 | 0.00 | 3960268.92 | 575459.50 | 0.622735E+09 | 0.885193E+09 | 0.00 | 0.47 |
March | 0.392970E+09 | 7540888.98 | 0.00 | 4118935.56 | 412488.16 | 0.770571E+09 | 0.930953E+09 | 0.00 | 0.47 |
April | 0.220591E+09 | 18919994.72 | 0.00 | 6399500.66 | 2975597.45 | 0.196084E+09 | 0.106808E+10 | 0.00 | 0.47 |
May | 0.213666E+09 | 2478752.26 | 0.00 | 5992939.20 | 4931429.35 | 0.200624E+09 | 0.101272E+10 | 0.00 | 0.47 |
June | 0.103383E+09 | 70277551.95 | 71845.80 | 5958415.33 | 42029832.55 | 13742837.70 | 0.709653E+09 | 5368.73 | 0.48 |
July | 20000638.62 | 0.355565E+09 | 81044.13 | 4836571.64 | 68689366.21 | 223763.56 | 0.331390E+09 | 9170.69 | 0.48 |
August | 17430162.50 | 0.475819E+09 | 19680.23 | 4348102.72 | 52264093.66 | 261579.56 | 0.262479E+09 | 4554.25 | 0.48 |
September | 78555248.49 | 0.170611E+09 | 131370.36 | 5217472.21 | 38778117.73 | 7388539.95 | 0.625402E+09 | 4890.13 | 0.48 |
October | 85226050.05 | 0.283645E+09 | 283621.04 | 5373603.07 | 50019415.53 | 84562595.14 | 0.749618E+09 | 6105.03 | 0.48 |
November | 0.243204E+09 | 11905179.94 | 1681.05 | 5423089.64 | 1804040.76 | 0.443181E+09 | 0.108734E+10 | 344.48 | 0.47 |
December | 0.285809E+09 | 11850522.07 | 0.00 | 5285097.29 | 2120550.34 | 0.721140E+09 | 0.981180E+09 | 0.00 | 0.47 |
Annual Sum or Average | 0.225097E+10 | 0.142422E+10 | 589242.61 | 62044528.64 | 0.270051E+09 | 0.378743E+10 | 0.968424E+10 | 30433.30 | 0.47 |
Minimum of Months | 17430162.50 | 2478752.26 | 0.00 | 3960268.92 | 412488.16 | 223763.56 | 0.262479E+09 | 0.00 | 0.47 |
Maximum of Months | 0.392970E+09 | 0.475819E+09 | 283621.04 | 6399500.66 | 68689366.21 | 0.770571E+09 | 0.108734E+10 | 9170.69 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_6_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.342918E+09 | 1756181.87 | 18048.84 | 1768317.04 | 15494656.08 | 0.115071E+10 | 0.558507E+09 | 1141.84 | 0.47 |
February | 0.352365E+09 | 707415.77 | 7040.57 | 1734872.36 | 3649523.33 | 0.899300E+09 | 0.567008E+09 | 264.90 | 0.47 |
March | 0.407172E+09 | 1381741.65 | 27338.88 | 2562521.79 | 6542858.19 | 0.993957E+09 | 0.694921E+09 | 1438.41 | 0.47 |
April | 0.234319E+09 | 10092331.78 | 44369.11 | 5282117.86 | 11757614.85 | 0.259097E+09 | 0.992452E+09 | 1276.43 | 0.47 |
May | 0.214133E+09 | 2264341.44 | 4842.42 | 5818574.80 | 5140962.92 | 0.212594E+09 | 0.100046E+10 | 34.83 | 0.47 |
June | 0.103150E+09 | 68145196.75 | 42240.27 | 6090775.38 | 44192252.65 | 14410123.34 | 0.709086E+09 | 4909.35 | 0.48 |
July | 19966368.53 | 0.348017E+09 | 67428.16 | 4879877.90 | 76251624.45 | 232634.89 | 0.331372E+09 | 8783.01 | 0.48 |
August | 18242450.12 | 0.418151E+09 | 56736.62 | 3999153.41 | 0.109892E+09 | 266514.74 | 0.262011E+09 | 7839.30 | 0.48 |
September | 86605760.06 | 0.114221E+09 | 371606.47 | 4078602.33 | 94918474.91 | 22503217.03 | 0.603375E+09 | 13654.72 | 0.48 |
October | 0.100477E+09 | 0.209944E+09 | 804679.81 | 3525927.56 | 0.123186E+09 | 0.179785E+09 | 0.640992E+09 | 18868.60 | 0.48 |
November | 0.303475E+09 | 1953430.48 | 1366.34 | 2068252.72 | 11754697.07 | 0.735908E+09 | 0.737698E+09 | 1752.32 | 0.47 |
December | 0.323025E+09 | 3767064.90 | 0.00 | 1654264.86 | 10203989.61 | 0.112390E+10 | 0.544834E+09 | 17.90 | 0.47 |
Annual Sum or Average | 0.250585E+10 | 0.118040E+10 | 1445697.50 | 43463258.02 | 0.512986E+09 | 0.559266E+10 | 0.764272E+10 | 59981.62 | 0.47 |
Minimum of Months | 18242450.12 | 707415.77 | 0.00 | 1654264.86 | 3649523.33 | 232634.89 | 0.262011E+09 | 17.90 | 0.47 |
Maximum of Months | 0.407172E+09 | 0.418151E+09 | 804679.81 | 6090775.38 | 0.123186E+09 | 0.115071E+10 | 0.100046E+10 | 18868.60 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: CORRIDOR_FLR_3
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.233299E+11 | 0.00 | 0.00 | 0.00 | 0.117406E+09 | 0.304810E+10 | 0.00 | 0.00 | 0.53 |
February | 0.230924E+11 | 0.00 | 0.00 | 0.00 | 22892986.47 | 0.549411E+09 | 0.00 | 0.00 | 0.54 |
March | 0.244707E+11 | 0.00 | 0.00 | 0.00 | 65627616.12 | 0.276445E+10 | 0.00 | 0.00 | 0.54 |
April | 0.202825E+11 | 0.00 | 0.00 | 0.00 | 0.216576E+09 | 0.262172E+09 | 0.00 | 0.00 | 0.54 |
May | 0.205526E+11 | 0.00 | 0.00 | 0.00 | 47037378.17 | 0.00 | 0.00 | 0.00 | 0.54 |
June | 0.136145E+11 | 0.00 | 0.00 | 0.00 | 0.127819E+10 | 0.00 | 0.00 | 0.00 | 0.54 |
July | 0.651932E+10 | 0.00 | 0.00 | 0.00 | 0.533473E+10 | 0.00 | 0.00 | 0.00 | 0.54 |
August | 0.484891E+10 | 0.00 | 0.00 | 0.00 | 0.665803E+10 | 0.00 | 0.00 | 0.00 | 0.54 |
September | 0.106787E+11 | 0.00 | 0.00 | 0.00 | 0.248678E+10 | 0.00 | 0.00 | 0.00 | 0.54 |
October | 0.130795E+11 | 0.00 | 0.00 | 0.00 | 0.336441E+10 | 0.00 | 0.00 | 0.00 | 0.54 |
November | 0.234411E+11 | 0.00 | 0.00 | 0.00 | 67874905.54 | 0.00 | 0.00 | 0.00 | 0.53 |
December | 0.245517E+11 | 0.00 | 0.00 | 0.00 | 58621929.12 | 0.125375E+10 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.208462E+12 | 0.00 | 0.00 | 0.00 | 0.197182E+11 | 0.787789E+10 | 0.00 | 0.00 | 0.54 |
Minimum of Months | 0.484891E+10 | 0.00 | 0.00 | 0.00 | 22892986.47 | 0.00 | 0.00 | 0.00 | 0.53 |
Maximum of Months | 0.245517E+11 | 0.00 | 0.00 | 0.00 | 0.665803E+10 | 0.304810E+10 | 0.00 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_1_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 65381084.03 | 2917736.34 | 0.00 | 1051688.77 | 1399770.81 | 0.248487E+09 | 0.198555E+09 | 0.00 | 0.47 |
February | 74515228.84 | 912811.81 | 0.00 | 952673.51 | 178249.33 | 0.210097E+09 | 0.169537E+09 | 0.00 | 0.47 |
March | 92898517.56 | 1426508.86 | 0.00 | 982182.22 | 561835.43 | 0.250176E+09 | 0.180597E+09 | 0.00 | 0.47 |
April | 48995913.32 | 3636541.17 | 69.60 | 1813202.95 | 1836932.00 | 68403043.54 | 0.253575E+09 | 355.27 | 0.47 |
May | 46680403.71 | 654587.80 | 0.00 | 1905360.21 | 1197957.60 | 66988859.60 | 0.242677E+09 | 0.00 | 0.47 |
June | 22504706.49 | 20105230.06 | 0.00 | 1876498.14 | 7990919.70 | 7160765.46 | 0.176642E+09 | 0.00 | 0.48 |
July | 5172615.36 | 88121442.55 | 34463.80 | 1344845.14 | 17928721.07 | 71621.81 | 82523609.31 | 1611.03 | 0.48 |
August | 4741360.27 | 0.113289E+09 | 52816.19 | 1158565.57 | 18683224.41 | 77437.44 | 65152320.71 | 1633.49 | 0.48 |
September | 18699596.07 | 43061579.36 | 21838.46 | 1596602.96 | 9297181.63 | 2281853.94 | 0.156563E+09 | 700.36 | 0.48 |
October | 22476828.19 | 73756578.97 | 103621.60 | 1224412.23 | 9624577.09 | 39210608.30 | 0.168283E+09 | 3729.45 | 0.48 |
November | 57716128.84 | 2929433.43 | 671.35 | 1313840.93 | 497206.51 | 0.159297E+09 | 0.226460E+09 | 500.27 | 0.47 |
December | 65834622.18 | 2986510.32 | 1676.30 | 1174388.66 | 504485.21 | 0.237584E+09 | 0.193761E+09 | 96.28 | 0.47 |
Annual Sum or Average | 0.525617E+09 | 0.353798E+09 | 215157.28 | 16394261.31 | 69701060.80 | 0.128983E+10 | 0.211433E+10 | 8626.14 | 0.47 |
Minimum of Months | 4741360.27 | 654587.80 | 0.00 | 952673.51 | 178249.33 | 71621.81 | 65152320.71 | 0.00 | 0.47 |
Maximum of Months | 92898517.56 | 0.113289E+09 | 103621.60 | 1905360.21 | 18683224.41 | 0.250176E+09 | 0.253575E+09 | 3729.45 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_2_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 84462780.49 | 1270415.70 | 673.44 | 339013.72 | 3046027.99 | 0.358359E+09 | 70314345.20 | 390.02 | 0.47 |
February | 85661406.14 | 231449.40 | 0.00 | 435922.08 | 859611.74 | 0.271975E+09 | 97030025.12 | 0.00 | 0.47 |
March | 99362209.61 | 702408.78 | 0.00 | 618571.35 | 1285935.50 | 0.302824E+09 | 0.121849E+09 | 0.00 | 0.47 |
April | 53028502.26 | 2293903.61 | 0.00 | 1528540.67 | 3179569.57 | 95541306.33 | 0.222689E+09 | 424.87 | 0.47 |
May | 47187726.83 | 630252.78 | 0.00 | 1865401.48 | 1222292.62 | 69305623.31 | 0.239893E+09 | 0.00 | 0.47 |
June | 22468545.06 | 20032269.64 | 0.00 | 1912213.21 | 8063880.12 | 7494314.98 | 0.176309E+09 | 0.00 | 0.48 |
July | 5163255.81 | 86443778.60 | 34373.59 | 1354927.68 | 19606385.03 | 65924.78 | 82528583.34 | 1701.24 | 0.48 |
August | 4854170.38 | 0.104204E+09 | 47120.35 | 1079885.54 | 27774594.32 | 83061.96 | 65112566.12 | 1593.72 | 0.48 |
September | 20228484.59 | 35296096.99 | 28390.48 | 1305013.39 | 17055748.61 | 5258859.77 | 0.152348E+09 | 1063.73 | 0.48 |
October | 24401495.53 | 60848113.86 | 105912.96 | 810838.57 | 22531674.66 | 69138262.46 | 0.136844E+09 | 2805.62 | 0.48 |
November | 71313558.97 | 1544149.79 | 165.05 | 537539.22 | 1882980.75 | 0.235396E+09 | 0.137541E+09 | 515.96 | 0.47 |
December | 79466643.15 | 1157526.70 | 982.60 | 377858.25 | 2333990.12 | 0.341199E+09 | 77309768.45 | 268.68 | 0.47 |
Annual Sum or Average | 0.597599E+09 | 0.314654E+09 | 217618.46 | 12165725.16 | 0.108843E+09 | 0.175664E+10 | 0.157977E+10 | 8763.84 | 0.47 |
Minimum of Months | 4854170.38 | 231449.40 | 0.00 | 339013.72 | 859611.74 | 65924.78 | 65112566.12 | 0.00 | 0.47 |
Maximum of Months | 99362209.61 | 0.104204E+09 | 105912.96 | 1912213.21 | 27774594.32 | 0.358359E+09 | 0.239893E+09 | 2805.62 | 0.48 |
Report: MechanicalVentilationLoadsMonthly
For: ROOM_3_MULT9_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.304281E+09 | 24019018.15 | 0.00 | 18473343.63 | 3708087.00 | 0.361404E+09 | 0.261339E+10 | 0.00 | 0.54 |
February | 0.404258E+09 | 6790164.78 | 0.00 | 12154394.39 | 216648.61 | 0.274950E+09 | 0.223131E+10 | 0.00 | 0.54 |
March | 0.533377E+09 | 12076564.37 | 0.00 | 9162565.01 | 692616.78 | 0.665032E+09 | 0.216176E+10 | 0.00 | 0.54 |
April | 0.309087E+09 | 28447099.08 | 0.00 | 9658733.08 | 6706368.19 | 0.101675E+09 | 0.197363E+10 | 0.00 | 0.54 |
May | 0.358178E+09 | 3979647.40 | 0.00 | 7130663.50 | 7917431.00 | 0.205350E+09 | 0.173004E+10 | 0.00 | 0.54 |
June | 0.177436E+09 | 91822692.93 | 13732.79 | 7196812.51 | 88595009.85 | 3038354.65 | 0.114929E+10 | 2520.87 | 0.54 |
July | 42453317.86 | 0.500420E+09 | 428641.82 | 5696491.19 | 0.180432E+09 | 657148.54 | 0.523476E+09 | 6064.70 | 0.54 |
August | 35803055.74 | 0.718773E+09 | 464648.10 | 6137828.22 | 0.128632E+09 | 628591.74 | 0.414227E+09 | 10304.59 | 0.54 |
September | 0.118110E+09 | 0.290349E+09 | 0.00 | 9803398.65 | 46044904.30 | 1514869.40 | 0.102102E+10 | 0.00 | 0.54 |
October | 0.132830E+09 | 0.488481E+09 | 227412.17 | 11099166.91 | 47454832.53 | 3929819.87 | 0.133688E+10 | 1776.72 | 0.54 |
November | 0.255428E+09 | 20753683.97 | 0.00 | 17760620.52 | 1259780.72 | 20920123.51 | 0.256232E+10 | 0.00 | 0.54 |
December | 0.301715E+09 | 21809714.17 | 0.00 | 19414364.57 | 620902.61 | 0.180808E+09 | 0.269850E+10 | 0.00 | 0.54 |
Annual Sum or Average | 0.297296E+10 | 0.220772E+10 | 1134434.88 | 0.133688E+09 | 0.512281E+09 | 0.181991E+10 | 0.204158E+11 | 20666.89 | 0.54 |
Minimum of Months | 35803055.74 | 3979647.40 | 0.00 | 5696491.19 | 216648.61 | 628591.74 | 0.414227E+09 | 0.00 | 0.54 |
Maximum of Months | 0.533377E+09 | 0.718773E+09 | 464648.10 | 19414364.57 | 0.180432E+09 | 0.665032E+09 | 0.269850E+10 | 10304.59 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: BANQUET_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.551241E+10 | 96795159.01 | 0.00 | 41628088.54 | 0.109382E+09 | 0.00 | 0.425266E+11 | 0.00 | 4.57 |
February | 0.205754E+10 | 25869484.32 | 0.00 | 42912390.13 | 14332971.10 | 0.00 | 0.420810E+11 | 0.00 | 4.69 |
March | 0.302146E+10 | 0.108335E+09 | 0.00 | 46949806.76 | 6913434.13 | 0.00 | 0.476706E+11 | 0.00 | 4.69 |
April | 0.778282E+09 | 0.348524E+09 | 0.00 | 51567143.41 | 31805348.71 | 0.00 | 0.383229E+11 | 0.00 | 4.74 |
May | 0.735294E+09 | 80293562.49 | 0.00 | 54837013.03 | 2308945.56 | 0.00 | 0.384688E+11 | 0.00 | 4.75 |
June | 0.294381E+09 | 0.205417E+10 | 0.00 | 52534705.43 | 0.190818E+09 | 0.00 | 0.254456E+11 | 0.00 | 4.71 |
July | 68529033.79 | 0.863210E+10 | 0.00 | 43760604.27 | 0.756186E+09 | 0.00 | 0.121092E+11 | 0.00 | 4.66 |
August | 50349311.39 | 0.105838E+11 | 0.00 | 39197779.38 | 0.112442E+10 | 0.00 | 0.906907E+10 | 0.00 | 4.65 |
September | 0.348288E+09 | 0.379269E+10 | 0.00 | 46082020.91 | 0.593066E+09 | 0.00 | 0.194045E+11 | 0.00 | 4.65 |
October | 0.592289E+09 | 0.538609E+10 | 0.00 | 40904116.63 | 0.558255E+09 | 0.00 | 0.238064E+11 | 0.00 | 4.63 |
November | 0.201643E+10 | 98217923.52 | 0.00 | 45595742.80 | 20977440.86 | 0.00 | 0.419357E+11 | 0.00 | 4.68 |
December | 0.393250E+10 | 54141670.49 | 0.00 | 42694698.56 | 48804508.91 | 0.00 | 0.434211E+11 | 0.00 | 4.59 |
Annual Sum or Average | 0.194078E+11 | 0.312610E+11 | 0.00 | 0.548664E+09 | 0.345727E+10 | 0.00 | 0.384261E+12 | 0.00 | 4.67 |
Minimum of Months | 50349311.39 | 25869484.32 | 0.00 | 39197779.38 | 2308945.56 | 0.00 | 0.906907E+10 | 0.00 | 4.57 |
Maximum of Months | 0.551241E+10 | 0.105838E+11 | 0.00 | 54837013.03 | 0.112442E+10 | 0.00 | 0.476706E+11 | 0.00 | 4.75 |
Report: MechanicalVentilationLoadsMonthly
For: DINING_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.268664E+10 | 0.209857E+09 | 0.00 | 53922455.91 | 6688797.05 | 0.00 | 0.490376E+11 | 0.00 | 4.90 |
February | 0.884310E+09 | 33477965.68 | 0.00 | 55068191.05 | 8746150.74 | 0.00 | 0.469852E+11 | 0.00 | 5.06 |
March | 0.131641E+10 | 0.114295E+09 | 0.00 | 60557556.21 | 6749687.44 | 0.00 | 0.535099E+11 | 0.00 | 5.06 |
April | 0.388657E+09 | 0.374095E+09 | 0.00 | 64589975.09 | 25360011.73 | 0.00 | 0.421774E+11 | 0.00 | 5.12 |
May | 0.305218E+09 | 84331285.12 | 0.00 | 69200189.44 | 2425055.51 | 0.00 | 0.423878E+11 | 0.00 | 5.13 |
June | 0.151756E+09 | 0.222747E+10 | 0.00 | 63806117.84 | 0.131363E+09 | 0.00 | 0.278461E+11 | 0.00 | 5.07 |
July | 36084140.24 | 0.945041E+10 | 0.00 | 50699915.97 | 0.435244E+09 | 0.00 | 0.131735E+11 | 0.00 | 4.99 |
August | 35434661.16 | 0.116634E+11 | 0.00 | 44557953.07 | 0.652803E+09 | 0.00 | 0.985753E+10 | 0.00 | 4.98 |
September | 0.166609E+09 | 0.434171E+10 | 0.00 | 55510131.31 | 0.275051E+09 | 0.00 | 0.212439E+11 | 0.00 | 4.98 |
October | 0.268659E+09 | 0.591784E+10 | 0.00 | 49644400.17 | 0.348764E+09 | 0.00 | 0.261705E+11 | 0.00 | 4.96 |
November | 0.881267E+09 | 0.120612E+09 | 0.00 | 57861096.49 | 4577042.73 | 0.00 | 0.467795E+11 | 0.00 | 5.04 |
December | 0.127941E+10 | 91754347.40 | 0.00 | 55214208.40 | 16368686.87 | 0.00 | 0.497956E+11 | 0.00 | 4.93 |
Annual Sum or Average | 0.840045E+10 | 0.346292E+11 | 0.00 | 0.680632E+09 | 0.191414E+10 | 0.00 | 0.428964E+12 | 0.00 | 5.02 |
Minimum of Months | 35434661.16 | 33477965.68 | 0.00 | 44557953.07 | 2425055.51 | 0.00 | 0.985753E+10 | 0.00 | 4.90 |
Maximum of Months | 0.268664E+10 | 0.116634E+11 | 0.00 | 69200189.44 | 0.652803E+09 | 0.00 | 0.535099E+11 | 0.00 | 5.13 |
Report: MechanicalVentilationLoadsMonthly
For: KITCHEN_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 72303549.99 | 0.292985E+09 | 0.00 | 0.110471E+09 | 0.00 | 0.00 | 0.636629E+11 | 0.00 | 20.30 |
February | 0.00 | 59058622.89 | 0.00 | 0.100660E+09 | 0.00 | 0.00 | 0.587694E+11 | 0.00 | 20.86 |
March | 57792366.41 | 0.165765E+09 | 0.00 | 0.108971E+09 | 0.00 | 0.00 | 0.671895E+11 | 0.00 | 20.87 |
April | 0.00 | 0.557703E+09 | 0.00 | 0.107095E+09 | 0.00 | 0.00 | 0.501341E+11 | 0.00 | 20.69 |
May | 0.00 | 0.117841E+09 | 0.00 | 0.114513E+09 | 0.00 | 0.00 | 0.496938E+11 | 0.00 | 20.53 |
June | 0.00 | 0.329756E+10 | 0.00 | 92099994.94 | 0.00 | 0.00 | 0.317597E+11 | 0.00 | 20.12 |
July | 0.00 | 0.139878E+11 | 0.00 | 58185533.58 | 0.00 | 0.00 | 0.144320E+11 | 0.00 | 19.87 |
August | 0.00 | 0.173516E+11 | 0.00 | 47927337.47 | 0.00 | 0.00 | 0.107670E+11 | 0.00 | 19.87 |
September | 0.00 | 0.633602E+10 | 0.00 | 78797592.37 | 0.00 | 0.00 | 0.246786E+11 | 0.00 | 20.01 |
October | 0.00 | 0.847333E+10 | 0.00 | 77831476.09 | 0.00 | 0.00 | 0.302196E+11 | 0.00 | 19.83 |
November | 0.00 | 0.173715E+09 | 0.00 | 0.109014E+09 | 0.00 | 0.00 | 0.575398E+11 | 0.00 | 20.59 |
December | 8324557.57 | 0.147829E+09 | 0.00 | 0.111673E+09 | 0.00 | 0.00 | 0.628826E+11 | 0.00 | 20.36 |
Annual Sum or Average | 0.138420E+09 | 0.509612E+11 | 0.00 | 0.111724E+10 | 0.00 | 0.00 | 0.521729E+12 | 0.00 | 20.32 |
Minimum of Months | 0.00 | 59058622.89 | 0.00 | 47927337.47 | 0.00 | 0.00 | 0.107670E+11 | 0.00 | 19.83 |
Maximum of Months | 72303549.99 | 0.173516E+11 | 0.00 | 0.114513E+09 | 0.00 | 0.00 | 0.671895E+11 | 0.00 | 20.87 |
Report: MechanicalVentilationLoadsMonthly
For: CORRIDOR_FLR_6
Timestamp: 2020-06-03 19:47:16
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.115995E+11 | 0.00 | 0.00 | 0.00 | 54181142.15 | 0.573560E+09 | 0.00 | 0.00 | 0.93 |
February | 0.109103E+11 | 0.00 | 0.00 | 0.00 | 10564767.14 | 0.00 | 0.00 | 0.00 | 0.94 |
March | 0.121009E+11 | 0.00 | 0.00 | 0.00 | 30286152.63 | 0.467771E+09 | 0.00 | 0.00 | 0.94 |
April | 0.948108E+10 | 0.00 | 0.00 | 0.00 | 99946326.18 | 0.00 | 0.00 | 0.00 | 0.94 |
May | 0.948469E+10 | 0.00 | 0.00 | 0.00 | 21707038.88 | 0.00 | 0.00 | 0.00 | 0.94 |
June | 0.628290E+10 | 0.00 | 0.00 | 0.00 | 0.589866E+09 | 0.00 | 0.00 | 0.00 | 0.94 |
July | 0.300857E+10 | 0.00 | 0.00 | 0.00 | 0.246190E+10 | 0.00 | 0.00 | 0.00 | 0.94 |
August | 0.223770E+10 | 0.00 | 0.00 | 0.00 | 0.307258E+10 | 0.00 | 0.00 | 0.00 | 0.94 |
September | 0.492806E+10 | 0.00 | 0.00 | 0.00 | 0.114761E+10 | 0.00 | 0.00 | 0.00 | 0.94 |
October | 0.603597E+10 | 0.00 | 0.00 | 0.00 | 0.155262E+10 | 0.00 | 0.00 | 0.00 | 0.94 |
November | 0.108177E+11 | 0.00 | 0.00 | 0.00 | 31323242.72 | 0.00 | 0.00 | 0.00 | 0.93 |
December | 0.118389E+11 | 0.00 | 0.00 | 0.00 | 27053134.00 | 69941976.70 | 0.00 | 0.00 | 0.93 |
Annual Sum or Average | 0.987262E+11 | 0.00 | 0.00 | 0.00 | 0.909964E+10 | 0.111127E+10 | 0.00 | 0.00 | 0.94 |
Minimum of Months | 0.223770E+10 | 0.00 | 0.00 | 0.00 | 10564767.14 | 0.00 | 0.00 | 0.00 | 0.93 |
Maximum of Months | 0.121009E+11 | 0.00 | 0.00 | 0.00 | 0.307258E+10 | 0.573560E+09 | 0.00 | 0.00 | 0.94 |