Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820
Simulation Timestamp: 2020-06-03 19:13:43
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1234.13 | 537.98 | 537.98 |
Net Site Energy | 1234.13 | 537.98 | 537.98 |
Total Source Energy | 3720.13 | 1621.68 | 1621.68 |
Net Source Energy | 3720.13 | 1621.68 | 1621.68 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 5.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 506.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 250.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 42.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 149.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 85.00 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1143.70 | 90.42 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 5.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 506.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 250.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 42.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 149.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 85.00 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 127.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 285.88 | 39.42 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 498.57 | 39.42 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 127.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 285.88 | 39.42 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 498.57 | 39.42 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1143.705 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1143.705 | 100.00 |
Total On-Site and Utility Electric Sources | 1143.705 | 100.00 |
Total Electricity End Uses | 1143.705 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 644.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2018
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1B
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY IND_DELHI_NEWDELHI
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13 |
RunPeriod | RUNPERIOD 1 |
Weather File | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
Latitude [deg] | 28.58 |
Longitude [deg] | 77.20 |
Elevation [m] | 216.00 |
Time Zone | 5.50 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 23.78 |
Skylight-Roof Ratio [%] | 1.04 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 5.1793 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 11.8188 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 11.8188 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 11.8188 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 9.6875 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 10.7081 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 10.7081 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 10-JUN-15:00 | 02-JAN-07:10 | - | - | - | 01-MAY-11:09 |
Heating | 0.00 | 109597.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 73348.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 17624.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 13758.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 115502.61 | 111459.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 109597.96 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 73348.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 17624.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 13758.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 5.87 | 0.00 | 0.00 | 0.00 |
Cooling | 1604.71 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 791.98 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 135.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 472.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 92.14 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3622.11 | 98.02 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 2.56 | 0.00 | 0.00 | 0.00 |
Cooling | 699.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 345.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 58.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 205.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 40.17 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1578.96 | 42.73 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 2.56 | 0.00 | 0.00 | 0.00 |
Cooling | 699.53 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 345.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 58.91 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 205.85 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 40.17 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1578.96 | 42.73 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 2.22 |
CORE_RETAIL DIRECT AIR | 7.43 |
POINT_OF_SALE DIRECT AIR | 1.25 |
FRONT_RETAIL DIRECT AIR | 1.00 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 0.712134 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 0.712134 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 20473.53 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 54094.11 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 201322.21 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 31332.95 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 25726.13 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 2.22 | 2.22 | 2.22 | 2.22 | 2.22 | 2.22 | 1.00 | 1.00 | 2.22 |
PSZ-AC:2 | 7.43 | 7.43 | 7.43 | 7.43 | 7.62 | 7.62 | 1.00 | 0.975446 | 7.62 |
PSZ-AC:3 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.00 | 1.00 | 1.25 |
PSZ-AC:4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 2.22 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 7.62 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.25 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 1.00 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 2.22 | 2.22 | 2.22 | 1.46 | 43762.11 | 54094.11 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 7.62 | 7.62 | 7.62 | 5.03 | 189261.46 | 201322.21 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.25 | 1.25 | 1.25 | 0.827230 | 28271.06 | 31332.95 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 1.00 | 1.00 | 1.00 | 0.663168 | 23621.92 | 25726.13 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 2.22 | 1.11 | 1.48 | 40785.08 | 43762.11 | 21881.06 | 21881.06 | 0.739357 | 0.739360 | 0.739360 | 0.739360 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 7.62 | 3.81 | 5.08 | 186638.76 | 189261.46 | 94630.73 | 94630.73 | 0.676083 | 0.676080 | 0.676080 | 0.676080 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.25 | 0.626690 | 0.835587 | 26538.85 | 28271.06 | 14135.53 | 14135.53 | 0.700819 | 0.700820 | 0.700820 | 0.700820 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 1.00 | 0.502400 | 0.669867 | 22257.24 | 23621.92 | 11810.96 | 11810.96 | 0.689879 | 0.689880 | 0.689880 | 0.689880 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.22 | 2372.59 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 7.62 | 12840.15 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.25 | 1387.69 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.00 | 1112.47 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 25.10 | 19.60 | 14.50 | 13.40 | 17.00 | 22.40 | 29.10 | 33.00 | 33.60 | 31.70 | 30.00 | 28.70 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 | 28.58 | 77.20 | 5.50 | 216.00 | 98757 | 1.1738 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 24.84 | 20.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 5.179 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 13.249 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 11.819 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 15.049 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 11.819 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 33.339 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 11.819 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 15.049 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 9.688 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 9.688 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 1967.547 | 5.179 | 32.075 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1967.547 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 18915.745 | 11.819 | 73.194 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 18915.745 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 1782.389 | 11.819 | 73.194 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1782.389 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 1782.389 | 11.819 | 73.194 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1782.389 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 116.250 | 9.688 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 116.250 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.760 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.9837 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.5681 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8493 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637443 | 3.4637443 | 3.4637443 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.7602635 | 1.7602635 | 1.7602635 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
21 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
22 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
23 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
24 | 9 | 0.31844121E-15 | 0.33891907E-16 | -0.14717764E-09 | -0.34085343E-17 |
25 | 8 | 0.21517510E-07 | 0.13210865E-12 | 0.37403321E-03 | -0.24466149E-09 |
26 | 7 | -0.12129356E-01 | 0.68855956E-08 | -0.22924263E-01 | 0.13791520E-03 |
27 | 6 | 0.40230169 | 0.24029480E-05 | 0.46949424 | -0.47118258E-02 |
28 | 5 | -5.1608121 | 0.89965799E-04 | -4.4213154 | 0.62814943E-01 |
29 | 4 | 32.871256 | 0.73775273E-03 | 21.362378 | -0.42037561 |
30 | 3 | -110.94624 | 0.16114037E-02 | -55.469893 | 1.5111496 |
31 | 2 | 196.85374 | 0.90819125E-03 | 77.733479 | -2.8963115 |
32 | 1 | -171.06207 | 0.97128343E-04 | -55.213590 | 2.7437919 |
33 | 0 | 57.057407 | 0.55402955E-06 | 15.565444 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.5_SHGC_0.25 | 30 | 1 | VerySmooth | 2.843 | 0.252 | 0.162 | 0.251 |
2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 31 | 1 | VerySmooth | 5.108 | 0.600 | 0.461 | 0.601 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 1.97990E-002 | 0.16139 | 0.61114 | 0.61114 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.10909 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.46039 | 0.10300 | 0.10300 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 6.93520E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1928 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.249 | 6.557E-004 | 2.976E-004 | 0.387 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.204 | 1.274E-004 | 1.036E-004 | 7.518E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 1.387E-002 | 1.156E-003 | 3.812E-004 | 0.682 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 1.419 | 0.118 | 3.899E-002 | 69.771 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 25320.33803 | 30384.40563 | 1.84773 | 2.21728 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 34.82200 | 9.11022E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 17239.70252 | 20687.64303 | 0.74050 | 0.88860 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 85515.29278 | 102618.35133 | 6.19535 | 7.43442 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 34.82200 | 9.11022E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 49418.35702 | 59302.02842 | 2.09449 | 2.51338 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 14190.48824 | 17028.58589 | 1.04448 | 1.25338 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 34.82200 | 9.11022E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 8401.91645 | 10082.29974 | 0.36267 | 0.43520 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 11429.37413 | 13715.24896 | 0.83733 | 1.00480 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 34.82200 | 9.11022E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 8406.54171 | 10087.85005 | 0.36287 | 0.43545 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 6.30000 | 6.07234E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 42.00000 | 9.11023E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 17059.62880 | 20471.55456 | 0.59345 | 0.71213 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 6.30000 | 6.07234E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 32093.29 | 2.21728 | 2.21728 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 24057.65 | 0.88860 | 0.88860 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 133643.89 | 7.62156 | 7.62156 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 89317.22 | 2.51338 | 2.51338 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 19620.68 | 1.25338 | 1.25338 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 12878.50 | 0.43520 | 0.43520 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 16743.48 | 1.00480 | 1.00480 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 12884.01 | 0.43545 | 0.43545 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.21728 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 7.43442 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.25338 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.00480 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.71213 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 0.71213 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 20473.53480 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.21728 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.21728 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.21728 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.21728 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.21728 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.21728 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 7.43442 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 7.43442 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 7.43442 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 7.43442 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 7.62156 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 7.62156 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.97545 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.25338 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.25338 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.25338 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.25338 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.25338 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.25338 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.00480 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.00480 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.00480 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.00480 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.00480 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.00480 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 2.21728 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 7.62156 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.25338 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 1.00480 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.21728 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.21728 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.21728 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.21728 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.46340 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.21728 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.10864 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.47819 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 40785.07543 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 43762.11000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 21881.05500 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 21881.05500 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.73936 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.73936 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.73936 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.73936 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 43762.11000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 54094.10861 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.21728 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2372.58964 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 54094.10861 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 7.62156 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 7.62156 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 7.62156 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 7.62156 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 5.03023 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 7.62156 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 3.81078 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 5.08104 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 186638.75923 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 189261.46000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 94630.73000 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 94630.73000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.67608 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.67608 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.67608 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.67608 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 189261.46000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 201322.21359 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 7.62156 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 12840.15232 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 201322.21359 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.25338 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.25338 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.25338 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.25338 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.82723 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.25338 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.62669 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.83559 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 26538.85021 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 28271.06000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 14135.53000 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14135.53000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70082 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70082 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70082 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70082 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 28271.06000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31332.94593 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.25338 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1387.68991 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31332.94593 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.00480 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.00480 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.00480 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.00480 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.66317 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.00480 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.50240 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.66987 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22257.23534 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23621.92000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11810.96000 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11810.96000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68988 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68988 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68988 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68988 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23621.92000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25726.13493 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.00480 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1112.47241 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25726.13493 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 42020.0 | 11.34 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 183248.7 | 13.35 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 27284.0 | 108.96 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 22830.1 | 142.92 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.760 | 1.760 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.760 | 1.760 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.760 | 1.760 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.760 | 1.760 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.760 | 1.760 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1576.70 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.25 | N/A | 2.843 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.25 | N/A | 2.843 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.984 | 0.857 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.5_SHGC_0.25 | N/A | 2.843 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 12 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 4.1791139035E-002 | 0.1585261689 | Pass | Pass | 0.2174736719 | 0.8140568031 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 3.2827650914E-002 | 0.1163197536 | Pass | Pass | 0.4089665684 | 2.3811430560 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 6.2940058132E-002 | 0.1155984156 | Pass | Pass | 0.4446294251 | 4.2090555263 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 4.8362976801E-002 | 0.1279671395 | Pass | Pass | 0.2180137358 | 0.6832912720 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.1595160048 | 0.4128950337 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 6.30 | 0.00 | 6.30 | Wetbulb [C] | 0.50 | 270.00 |
NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 42.00 | 9.70 | 22.20 | Wetbulb [C] | 3.20 | 320.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 1600.48 | 1576.70 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.857 | 0.984 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.5_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.843 | 0.252 | 0.251 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.5_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.843 | 0.252 | 0.251 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.5_SHGC_0.25 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.843 | 0.252 | 0.251 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 107.72 | 3.343 | 0.329 | 0.328 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 107.72 | 3.343 | 0.329 | 0.328 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.393 | 1.760 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 5.1793 | 379.89 | 1967.55 | LightsWired | BLDG_LIGHT_BACK_SCH | 60.89 | 168.00 | 60.06 | 0.0000 | Y | 22.18 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 11.8188 | 1600.48 | 18915.75 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 50.90 | 0.0000 | Y | 180.73 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 11.8188 | 150.81 | 1782.39 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 22.84 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 11.8188 | 150.81 | 1782.39 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 22.84 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 9.6875 | 12.00 | 116.25 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 1.49 |
Interior Lighting Total | 10.7081 | 2293.99 | 24564.32 | 250.07 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 18915.75 | 4728.94 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 18915.75 | 4728.94 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 238.00 | AstronomicalClock | - | 41.75 | 41.75 | 1.87 | |
EXTERIOR_LIGHTS_B | 3054.90 | AstronomicalClock | - | 83.75 | 71.15 | 40.80 | |
Exterior Lighting Total | 3292.90 | 42.67 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 43762.11 | 32355.95 | 11406.16 | 0.74 | 3.73 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 189261.46 | 127955.89 | 61305.57 | 0.68 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 28271.06 | 19812.92 | 8458.14 | 0.70 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23621.92 | 16296.29 | 7325.63 | 0.69 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 42020.0 | 11.34 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 183248.7 | 13.35 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 27284.0 | 108.96 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 22830.1 | 142.92 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 20473.53 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 54094.11 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 201322.21 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31332.95 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25726.13 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.56 | 622.50 | 0.71 | 788.45 | 1107.16 | 1.00 | 1.49 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 2.22 | 2372.59 | 1070.05 | 1.00 | 1.30 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1018.41 | 7.62 | 12840.15 | 1684.71 | 1.00 | 1.16 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.25 | 1387.69 | 1107.16 | 1.00 | 1.35 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.00 | 1112.47 | 1107.16 | 1.00 | 1.40 | General | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 25320.34 | 30384.41 | 79.98 | 1.848 | 2.217 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 23.89 | 23.89 | 0.00776 | 34.82 | 0.00911 | 0.232 | 0.00 |
CORE_RETAIL | 85515.29 | 102618.35 | 64.12 | 6.195 | 7.434 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 23.89 | 23.89 | 0.00823 | 34.82 | 0.00911 | 1.890 | 0.00 |
POINT_OF_SALE | 14190.49 | 17028.59 | 112.91 | 1.044 | 1.253 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 23.89 | 23.89 | 0.00742 | 34.82 | 0.00911 | 0.178 | 0.00 |
FRONT_RETAIL | 11429.37 | 13715.25 | 90.94 | 0.837 | 1.005 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 23.89 | 23.89 | 0.00761 | 34.82 | 0.00911 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 40.90 | 100.00 | 0.00001 | 42.00 | 0.00911 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 17239.70 | 20687.64 | 54.46 | 0.741 | 0.889 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00792 | 6.30 | 0.00607 | 0.232 | 0.00 |
CORE_RETAIL | 49418.36 | 59302.03 | 37.05 | 2.094 | 2.513 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00797 | 6.30 | 0.00607 | 1.890 | 0.00 |
POINT_OF_SALE | 8401.92 | 10082.30 | 66.85 | 0.363 | 0.435 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00794 | 6.30 | 0.00607 | 0.178 | 0.00 |
FRONT_RETAIL | 8406.54 | 10087.85 | 66.89 | 0.363 | 0.435 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00794 | 6.30 | 0.00607 | 0.178 | 0.00 |
FRONT_ENTRY | 17059.63 | 20471.55 | 1705.96 | 0.593 | 0.712 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 16.00 | 15.98 | 0.00663 | 6.30 | 0.00607 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 2.22 | 2.22 | 0.89 | 0.89 | 2.2173 | 2.2173 | 2.2173 | 1.0000 | 1.0000 |
PSZ-AC:2 | 7.62 | 7.62 | 2.51 | 2.51 | 7.6216 | 7.4344 | 7.6216 | 0.9754 | 1.0000 |
PSZ-AC:3 | 1.25 | 1.25 | 0.44 | 0.44 | 1.2534 | 1.2534 | 1.2534 | 1.0000 | 1.0000 |
PSZ-AC:4 | 1.00 | 1.00 | 0.44 | 0.44 | 1.0048 | 1.0048 | 1.0048 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 20473.535 | 20473.535 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 20473.53 | 20473.53 | 0.712134 | 15.79 | 11.20 | 0.00661459 | 40.00 | 20.85 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 0.0000 | 15.98 | 0.00662560 | 57.3137 | 20471.55 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 21881.055 | 0.000 | 2.217280 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:20:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 21881.06 | 19469.48 | 2.217280 | 25.10 | 15.92 | 0.00782844 | 12.80 | 10.33 | 0.00700000 | 35.44 | 0.00911022 | 20.30 | 10.4437 | 23.89 | 0.00775775 | 41.0330 | 25320.34 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 54094.109 | 54094.109 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 54094.11 | 54094.11 | 2.217276 | 17.05 | 12.54 | 0.00743736 | 40.00 | 20.85 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 10.4437 | 21.11 | 0.00791844 | 49.5694 | 17239.70 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 94630.730 | 0.000 | 7.621560 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:20:00 | 94630.73 | 83368.37 | 7.621560 | 28.69 | 17.38 | 0.00809459 | 12.80 | 10.33 | 0.00700000 | 42.00 | 0.00911023 | 22.20 | 24.8009 | 23.89 | 0.00823251 | 43.5152 | 78724.39 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 201322.214 | 201322.214 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 201322.21 | 201322.21 | 7.621559 | 9.87 | 8.54 | 0.00654391 | 40.00 | 20.85 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 24.8009 | 21.11 | 0.00797429 | 49.9142 | 49418.36 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 14135.530 | 0.000 | 1.253380 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 14135.53 | 12953.40 | 1.253380 | 26.56 | 16.29 | 0.00766290 | 12.80 | 10.33 | 0.00700000 | 42.00 | 0.00911023 | 22.20 | 14.2104 | 23.89 | 0.00742322 | 39.2820 | 13350.22 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 31332.946 | 31332.946 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 31332.95 | 31332.95 | 1.253379 | 14.91 | 11.40 | 0.00717300 | 40.00 | 20.85 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 14.2104 | 21.11 | 0.00793552 | 49.6750 | 8401.92 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 11810.960 | 0.000 | 1.004800 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:20:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 11810.96 | 10680.76 | 1.004800 | 27.15 | 16.61 | 0.00779335 | 12.80 | 10.33 | 0.00700000 | 42.00 | 0.00911023 | 22.20 | 17.7260 | 23.89 | 0.00761253 | 40.2732 | 10921.55 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 25726.135 | 25726.135 | -999.0 | -999.0 | -999.000 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25726.13 | 25726.13 | 1.004799 | 14.91 | 11.40 | 0.00717346 | 40.00 | 20.85 | 0.00800000 | 6.30 | 0.00607234 | 6.30 | 17.7260 | 21.11 | 0.00793559 | 49.6754 | 8406.54 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 20473.535 | 20473.535 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.712134 | 0.83589263 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 20473.53 | 20473.53 | 1.0000 | 0.83589263 | 0.712134 | 15.79 | 11.20 | 0.00661459 | 32601.0 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20473.53 | 6.30 | 0.00607234 | 6.30 | 0.00000000 | 0.0000 | 15.98 | 0.00662560 | 15.98 | 0.00662560 | 57.3137 | 20471.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 21881.055 | 0.000 | 2.217280 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.3927 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:20:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 21881.06 | 19469.48 | 1.0000 | 2.60261103 | 2.217280 | 25.10 | 15.92 | 0.00782844 | 45160.7 | 12.80 | 10.33 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 21881.06 | 35.44 | 0.00911022 | 20.30 | 0.23156651 | 10.4437 | 23.89 | 0.00767864 | 23.89 | 0.00775775 | 41.0330 | 25320.34 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 54094.109 | 54094.109 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.217276 | 2.60260579 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 54094.11 | 54094.11 | 1.0000 | 2.60260579 | 2.217276 | 17.05 | 12.54 | 0.00743736 | 35964.9 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 54094.11 | 6.30 | 0.00607234 | 6.30 | 0.23156651 | 10.4437 | 20.83 | 0.00791844 | 21.11 | 0.00791844 | 49.5694 | 17239.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 94630.730 | 0.000 | 7.621560 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8874 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:00:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:20:00 | 94630.73 | 83368.37 | 1.0000 | 8.94607631 | 7.621560 | 28.69 | 17.38 | 0.00809459 | 49503.3 | 12.80 | 10.33 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 94630.73 | 42.00 | 0.00911023 | 22.20 | 1.89021192 | 24.8009 | 23.89 | 0.00772830 | 23.89 | 0.00823251 | 43.5152 | 78724.39 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 201322.214 | 201322.214 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 7.621559 | 8.94607534 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 201322.21 | 201322.21 | 1.0000 | 8.94607534 | 7.621559 | 9.87 | 8.54 | 0.00654391 | 26404.9 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 201322.21 | 6.30 | 0.00607234 | 6.30 | 1.89021192 | 24.8009 | 20.70 | 0.00797429 | 21.11 | 0.00797429 | 49.9142 | 49418.36 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14135.530 | 0.000 | 1.253380 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.0850 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:10:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 14135.53 | 12953.40 | 1.0000 | 1.47119922 | 1.253380 | 26.56 | 16.29 | 0.00766290 | 46227.0 | 12.80 | 10.33 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14135.53 | 42.00 | 0.00911023 | 22.20 | 0.17811053 | 14.2104 | 23.89 | 0.00741292 | 23.89 | 0.00742322 | 39.2820 | 13350.22 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31332.946 | 31332.946 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.253379 | 1.47119847 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 31332.95 | 31332.95 | 1.0000 | 1.47119847 | 1.253379 | 14.91 | 11.40 | 0.00717300 | 33121.4 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31332.95 | 6.30 | 0.00607234 | 6.30 | 0.17811053 | 14.2104 | 20.88 | 0.00793552 | 21.11 | 0.00793552 | 49.6750 | 8401.92 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11810.960 | 0.000 | 1.004800 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.3274 | 1004.8586 | 1.1738 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:20:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 14:20:00 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN CLG .4% CONDNS DB=>MWB | 6/21 08:00:00 | 11810.96 | 10680.76 | 1.0000 | 1.17941963 | 1.004800 | 27.15 | 16.61 | 0.00779335 | 47164.3 | 12.80 | 10.33 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11810.96 | 42.00 | 0.00911023 | 22.20 | 0.17811053 | 17.7260 | 23.89 | 0.00750421 | 23.89 | 0.00761253 | 40.2732 | 10921.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25726.135 | 25726.135 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1738 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.004799 | 1.17941890 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.DELHI-SAFDARJUNG.AP_DELHI_IND ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25726.13 | 25726.13 | 1.0000 | 1.17941890 | 1.004799 | 14.91 | 11.40 | 0.00717346 | 33125.9 | 40.00 | 20.85 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25726.13 | 6.30 | 0.00607234 | 6.30 | 0.17811053 | 17.7260 | 20.88 | 0.00793559 | 21.11 | 0.00793559 | 49.6754 | 8406.54 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2985.17 | 1272.83 | 110.83 |
CORE_RETAIL | 3269.17 | 1403.17 | 640.67 |
POINT_OF_SALE | 3874.00 | 375.17 | 71.67 |
FRONT_RETAIL | 3638.83 | 679.67 | 173.83 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 3890.50 | 1810.17 | 644.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 0.00 | 0.50 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 0.00 | 1.83 | 0.00 | 0.00 |
FRONT_RETAIL | 0.00 | 0.17 | 0.00 | 0.00 |
FRONT_ENTRY | 50.00 | 0.00 | 0.00 | 0.00 |
Facility | 50.00 | 2.50 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.34 | 61.34 | 2317.33 | 0.372 | 0.013 | 0.000 | 0.000 |
CORE_RETAIL | 127.83 | 258.43 | 9762.95 | 0.720 | 0.002 | 0.000 | 0.000 |
POINT_OF_SALE | 12.05 | 24.35 | 919.94 | 0.719 | 0.014 | 0.000 | 0.000 |
FRONT_RETAIL | 12.05 | 24.35 | 919.94 | 0.719 | 0.014 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.34 | 61.34 | 2317.33 | 0.339 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 127.83 | 258.43 | 9762.95 | 0.657 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.05 | 24.35 | 919.94 | 0.660 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.05 | 24.35 | 919.94 | 0.658 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
Electricity:Building | 445.23 | 2708.13 | 14-MAY-08:00 | 32651.56 | 02-JAN-16:20 |
Electricity:Zone:BACK_SPACE | 72.17 | 558.23 | 01-JAN-00:10 | 4302.56 | 02-JAN-09:10 |
InteriorLights:Electricity | 250.07 | 912.95 | 14-MAY-08:00 | 21880.52 | 02-JAN-16:20 |
InteriorLights:Electricity:Zone:BACK_SPACE | 22.18 | 98.38 | 01-JAN-00:10 | 1543.42 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 250.07 | 912.95 | 14-MAY-08:00 | 21880.52 | 02-JAN-16:20 |
Electricity:Zone:CORE_RETAIL | 265.03 | 1405.96 | 14-MAY-08:00 | 21676.77 | 02-JAN-16:20 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 180.73 | 630.52 | 14-MAY-08:00 | 17024.17 | 02-JAN-16:20 |
Electricity:Zone:POINT_OF_SALE | 75.76 | 575.93 | 01-JAN-00:10 | 4525.04 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 22.84 | 89.12 | 01-JAN-00:10 | 1604.15 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 30.78 | 162.19 | 01-JAN-00:10 | 2042.55 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 22.84 | 89.12 | 01-JAN-00:10 | 1604.15 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 1.49 | 5.81 | 01-JAN-00:10 | 104.63 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 1.49 | 5.81 | 01-JAN-00:10 | 104.63 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
ElectricityPurchased:Plant | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
Cogeneration:ElectricityPurchased | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
ElectricityNet:Plant | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
Cogeneration:ElectricityNet | 1143.70 | 2865.76 | 05-MAR-08:00 | 115502.61 | 10-JUN-16:00 |
Electricity:HVAC | 655.81 | 0.00 | 01-JAN-00:10 | 87107.09 | 10-JUN-16:00 |
Fans:Electricity | 149.11 | 0.00 | 01-JAN-00:10 | 14236.99 | 01-JUL-15:00 |
General:Fans:Electricity | 149.11 | 0.00 | 01-JAN-00:10 | 14236.99 | 01-JUL-15:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 506.70 | 0.00 | 01-JAN-00:10 | 73348.86 | 10-JUN-16:00 |
ExteriorLights:Electricity | 42.67 | 0.00 | 01-JAN-07:20 | 3292.90 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 42.67 | 0.00 | 01-JAN-07:20 | 3292.90 | 01-JAN-06:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 90.42 | 1862.00 | 22-JAN-08:20 | 111459.96 | 02-JAN-07:10 |
Gas:Plant | 85.00 | 1862.00 | 21-JAN-08:20 | 4919.97 | 17-JAN-12:20 |
WaterSystems:Gas | 85.00 | 1862.00 | 21-JAN-08:20 | 4919.97 | 17-JAN-12:20 |
Water Heater:WaterSystems:Gas | 85.00 | 1862.00 | 21-JAN-08:20 | 4919.97 | 17-JAN-12:20 |
Gas:HVAC | 5.42 | 0.00 | 01-JAN-00:10 | 109597.96 | 02-JAN-07:10 |
Heating:Gas | 5.42 | 0.00 | 01-JAN-00:10 | 109597.96 | 02-JAN-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 01-MAY-11:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 2793.22 | 0.00 | 01-JAN-00:10 | 348046.98 | 08-JUL-06:10 |
EnergyTransfer:Building | 952.96 | 0.00 | 01-JAN-00:10 | 110908.80 | 29-MAY-08:10 |
EnergyTransfer:Zone:BACK_SPACE | 155.33 | 0.00 | 01-JAN-00:10 | 21281.95 | 05-JUL-06:10 |
Heating:EnergyTransfer | 2.82 | 0.00 | 01-JAN-00:10 | 69859.46 | 02-JAN-07:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 0.49 | 0.00 | 01-JAN-00:10 | 12900.07 | 02-JAN-07:10 |
Cooling:EnergyTransfer | 950.13 | 0.00 | 01-JAN-00:10 | 108876.26 | 12-JUN-14:20 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 154.84 | 0.00 | 01-JAN-00:10 | 21281.95 | 05-JUL-06:10 |
EnergyTransfer:Zone:CORE_RETAIL | 580.77 | 0.00 | 01-JAN-00:10 | 73442.87 | 29-MAY-08:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 2.06 | 0.00 | 01-JAN-00:10 | 47552.75 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 578.71 | 0.00 | 01-JAN-00:10 | 68565.49 | 29-MAY-08:10 |
EnergyTransfer:Zone:POINT_OF_SALE | 124.98 | 0.00 | 01-JAN-00:10 | 12479.34 | 02-OCT-14:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 0.10 | 0.00 | 01-JAN-00:10 | 4142.34 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 124.88 | 0.00 | 01-JAN-00:10 | 12479.34 | 02-OCT-14:10 |
EnergyTransfer:Zone:FRONT_RETAIL | 91.86 | 0.00 | 01-JAN-00:10 | 10430.25 | 02-OCT-14:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 0.17 | 0.00 | 01-JAN-00:10 | 5264.30 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 91.70 | 0.00 | 01-JAN-00:10 | 10430.25 | 02-OCT-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 0.02 | 0.00 | 01-JAN-00:10 | 1714.08 | 03-JAN-08:10 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 0.02 | 0.00 | 01-JAN-00:10 | 1714.08 | 03-JAN-08:10 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 1840.27 | 0.00 | 01-JAN-00:10 | 252668.79 | 18-JUL-06:10 |
HeatingCoils:EnergyTransfer | 4.33 | 0.00 | 01-JAN-00:10 | 87678.37 | 02-JAN-07:10 |
CoolingCoils:EnergyTransfer | 1835.93 | 0.00 | 01-JAN-00:10 | 252668.79 | 18-JUL-06:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 0.486 | -154.841 | 0.000 | 0.000 | 36.874 | 22.181 | 49.992 | 0.000 | 0.000 | 1.352 | 44.811 | 0.000 | 0.000 | 0.000 | -0.854 | -0.001 |
CORE_RETAIL | 0.000 | 0.000 | 2.057 | -578.702 | 0.000 | 0.000 | 155.419 | 180.730 | 84.299 | 86.404 | 0.000 | 1.157 | 83.171 | 0.000 | -13.801 | 0.000 | -0.734 | -0.006 |
POINT_OF_SALE | 0.000 | 0.000 | 0.098 | -124.876 | 0.000 | 0.000 | 14.579 | 22.836 | 52.922 | 35.887 | 0.000 | 0.549 | 7.597 | 0.000 | -9.160 | 0.000 | -0.433 | -0.001 |
FRONT_RETAIL | 0.000 | 0.000 | 0.166 | -91.696 | 0.000 | 0.000 | 14.624 | 22.836 | 7.943 | 35.944 | 0.000 | 0.574 | 18.705 | 0.000 | -8.703 | 0.000 | -0.394 | -0.001 |
FRONT_ENTRY | 0.018 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.489 | 0.000 | 6.483 | 0.000 | 4.231 | 0.000 | 0.000 | -1.851 | 0.000 | -4.677 | -5.694 |
Total Facility | 0.018 | 0.000 | 2.807 | -950.115 | 0.000 | 0.000 | 221.495 | 250.074 | 195.156 | 164.719 | 0.000 | 7.864 | 154.284 | 0.000 | -33.515 | 0.000 | -7.092 | -5.703 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 28-APR-05:01 | 0.00 | 0.00 | 0.00 | -39443.87 | 0.00 | 0.00 | 0.00 | 98.38 | 613.14 | 0.00 | 0.00 | 0.46 | 38731.89 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 08-APR-06:02 | 0.00 | 0.00 | 0.00 | -157083.79 | 0.00 | 0.00 | 1595.74 | 1891.57 | 1550.87 | 0.00 | 0.00 | 0.00 | 152594.27 | 0.00 | -537.78 | 0.00 | -10.88 | 0.00 |
POINT_OF_SALE | 28-APR-05:01 | 0.00 | 0.00 | 0.00 | -25295.18 | 0.00 | 0.00 | 0.00 | 89.12 | 649.09 | 0.00 | 0.00 | 0.00 | 24880.72 | 0.00 | -323.73 | 0.00 | -0.01 | 0.00 |
FRONT_RETAIL | 28-APR-05:01 | 0.00 | 0.00 | 0.00 | -20747.09 | 0.00 | 0.00 | 0.00 | 89.12 | 97.42 | 0.00 | 0.00 | 0.13 | 20844.73 | 0.00 | -284.31 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 28-APR-05:01 | 0.00 | 0.00 | 0.00 | -241528.20 | 0.00 | 0.00 | 0.00 | 1228.22 | 2393.56 | 0.00 | 0.00 | 1.13 | 239364.82 | 0.00 | -1459.45 | 0.00 | -0.07 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 01-JAN-08:61 | 0.00 | 0.00 | 52039.24 | 0.00 | 0.00 | 0.00 | 0.00 | 98.38 | 459.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -1.92 | -52595.55 |
CORE_RETAIL | 01-JAN-08:61 | 0.00 | 0.00 | 184443.90 | 0.00 | 0.00 | 0.00 | 0.00 | 945.79 | 775.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -358.53 | 0.00 | -1.68 | -185804.91 |
POINT_OF_SALE | 02-JAN-07:03 | 0.00 | 0.00 | 14321.15 | 0.00 | 0.00 | 0.00 | 210.89 | 356.48 | 1298.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1232.80 | 0.00 | 0.00 | -14953.90 |
FRONT_RETAIL | 01-JAN-08:61 | 0.00 | 0.00 | 23736.56 | 0.00 | 0.00 | 0.00 | 0.00 | 89.12 | 73.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -17.68 | 0.00 | -0.87 | -23880.20 |
FRONT_ENTRY | 05-JAN-08:04 | 3103.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.50 | 0.00 | 31.12 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -2574.41 | -606.39 |
Total Facility | 01-JAN-08:61 | 0.00 | 0.00 | 264289.14 | 0.00 | 0.00 | 0.00 | 0.00 | 1228.22 | 1795.17 | 11.20 | 0.00 | 0.00 | 0.00 | 0.00 | -455.96 | 0.00 | -2293.62 | -264574.15 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.2173 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.2173 | 0.1044 | 1.0000 | 0.2316 | 0.1044 | ||
PSZ-AC:2 | 7.4344 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.6216 | 0.2480 | 1.0000 | 1.8902 | 0.2480 | ||
PSZ-AC:3 | 1.2534 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.2534 | 0.1421 | 1.0000 | 0.1781 | 0.1421 | ||
PSZ-AC:4 | 1.0048 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0048 | 0.1773 | 1.0000 | 0.1781 | 0.1773 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.2173 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.2173 | 1.0000 | 1.0000 | 0.2316 | 0.1044 | ||
PSZ-AC:2 | 7.4344 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.4344 | 1.0000 | 1.0000 | 1.8902 | 0.2543 | ||
PSZ-AC:3 | 1.2534 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.2534 | 1.0000 | 1.0000 | 0.1781 | 0.1421 | ||
PSZ-AC:4 | 1.0048 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0048 | 1.0000 | 1.0000 | 0.1781 | 0.1773 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.2173 | 2.2173 | 2.2173 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.4344 | 7.4344 | 7.4344 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.2534 | 1.2534 | 1.2534 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0048 | 1.0048 | 1.0048 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.2173 | 2.2173 | 2.2173 | 2.2173 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.4344 | 7.6216 | 7.4344 | 7.4344 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.2534 | 1.2534 | 1.2534 | 1.2534 | 0.1781 | 1.0000 |
PSZ-AC:4 | 1.0048 | 1.0048 | 1.0048 | 1.0048 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.2173 | 2.2173 | 2.2173 | 0.2316 | 0.2606 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.4344 | 7.4344 | 7.4344 | 1.8902 | 0.7521 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.2534 | 1.2534 | 1.2534 | 0.1781 | 0.4093 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0048 | 1.0048 | 1.0048 | 0.1781 | 0.4090 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.2173 | 2.2173 | 2.2173 | 2.2173 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.4344 | 7.4344 | 7.4344 | 7.4344 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.2534 | 1.2534 | 1.2534 | 1.2534 | 0.1781 | 1.0000 |
PSZ-AC:4 | 1.0048 | 1.0048 | 1.0048 | 1.0048 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:43
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** New Delhi-Safdarjung AP Delhi IND IWEC2 WMO#=421820 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 5.42 | 109597.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 506.70 | 73348.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 250.07 | 21880.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 42.67 | 3292.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 149.11 | 14236.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 85.00 | 4919.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 1143.70 |
Natural Gas | 0.00 | 90.42 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 1234.13 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 109.01 |
Space Heating | 0.00 |
Space Cooling | 220.88 |
Fans (All) | 65.00 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 498.57 |
Subtotal | 498.57 |
Natural Gas [MJ/m2] | |
Space Heating | 2.36 |
Service Water Heating | 37.06 |
Miscellaneous (All) | 39.42 |
Subtotal | 39.42 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 20.26 |
Space Heating | 0.44 |
Space Cooling | 41.06 |
Fans (All) | 12.08 |
Service Water Heating | 6.89 |
Receptacle Equipment | 15.81 |
Miscellaneous | 3.46 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3175. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
HTGSETP_SCH_FRONTENTRY_STD2013 | FRONT_ENTRY DUALSPSCHED | January | 16.00 | 365 | 15.56 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2018
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 1B
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY IND_DELHI_NEWDELHI
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.463609E+10 |
February | 0.000 | 0.317393E+09 |
March | 0.000 | 0.000 |
April | 0.000 | 0.000 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.000 |
December | 0.000 | 0.464890E+09 |
Annual Sum or Average | 0.541838E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.463609E+10 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.259405E+10 | 4799.40 | 14-JAN-16:00 | 21.30 | 15.06 | 0.206411E+10 | 2451.26 | 24-JAN-15:39 | 20.43 | 11.61 |
February | 0.419688E+10 | 7377.37 | 24-FEB-15:50 | 26.32 | 17.45 | 0.196271E+10 | 2451.28 | 18-FEB-11:39 | 20.37 | 12.25 |
March | 0.899538E+10 | 33777.07 | 29-MAR-06:02 | 21.15 | 17.30 | 0.227936E+10 | 2451.31 | 04-MAR-11:30 | 24.95 | 15.28 |
April | 0.147554E+11 | 39443.55 | 28-APR-05:01 | 27.22 | 17.14 | 0.215720E+10 | 2451.33 | 28-APR-14:20 | 38.80 | 21.14 |
May | 0.202348E+11 | 39137.52 | 06-MAY-05:01 | 29.55 | 17.33 | 0.223343E+10 | 2451.36 | 06-MAY-11:09 | 38.85 | 19.66 |
June | 0.207811E+11 | 36671.85 | 07-JUN-05:01 | 33.20 | 19.47 | 0.220249E+10 | 2451.28 | 20-JUN-14:09 | 32.28 | 27.56 |
July | 0.208644E+11 | 32460.98 | 07-JUL-05:01 | 31.52 | 25.90 | 0.218816E+10 | 2451.24 | 28-JUL-14:20 | 30.23 | 26.43 |
August | 0.201910E+11 | 30839.71 | 09-AUG-05:01 | 29.90 | 25.20 | 0.228192E+10 | 2451.25 | 16-AUG-14:39 | 28.17 | 26.74 |
September | 0.169723E+11 | 34305.99 | 27-SEP-05:01 | 23.08 | 20.68 | 0.215730E+10 | 2451.29 | 02-SEP-10:09 | 29.75 | 26.54 |
October | 0.137595E+11 | 37090.91 | 02-OCT-05:01 | 21.60 | 17.46 | 0.218469E+10 | 2451.28 | 21-OCT-10:09 | 26.07 | 16.99 |
November | 0.770787E+10 | 21702.27 | 11-NOV-09:02 | 20.20 | 15.91 | 0.209790E+10 | 2451.28 | 07-NOV-15:50 | 28.20 | 18.05 |
December | 0.379151E+10 | 6022.66 | 01-DEC-15:10 | 23.22 | 13.40 | 0.213449E+10 | 2451.28 | 01-DEC-15:00 | 22.30 | 13.70 |
Annual Sum or Average | 0.154844E+12 | 0.259438E+11 | ||||||||
Minimum of Months | 0.259405E+10 | 4799.40 | 20.20 | 13.40 | 0.196271E+10 | 2451.24 | 20.37 | 11.61 | ||
Maximum of Months | 0.208644E+11 | 39443.55 | 33.20 | 25.90 | 0.228192E+10 | 2451.36 | 38.85 | 27.56 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.220117E+11 | 33817.60 | 05-JAN-07:05 | 4.93 | 4.82 | 0.869151E+10 | 10327.13 | 21-JAN-12:20 | 17.87 | 10.02 |
February | 0.259669E+11 | 33267.09 | 23-FEB-15:10 | 25.63 | 14.12 | 0.826337E+10 | 10327.12 | 23-FEB-15:00 | 24.80 | 14.33 |
March | 0.421729E+11 | 134685.95 | 13-MAR-06:02 | 20.65 | 15.51 | 0.960001E+10 | 10327.25 | 30-MAR-14:30 | 31.10 | 19.39 |
April | 0.572700E+11 | 157090.69 | 08-APR-06:02 | 23.28 | 14.20 | 0.908794E+10 | 10327.10 | 22-APR-14:50 | 30.72 | 18.74 |
May | 0.698862E+11 | 151957.88 | 06-MAY-05:01 | 29.55 | 17.33 | 0.940931E+10 | 10327.48 | 06-MAY-10:20 | 36.93 | 19.47 |
June | 0.687133E+11 | 136389.08 | 07-JUN-05:01 | 33.20 | 19.47 | 0.927904E+10 | 10326.99 | 03-JUN-11:20 | 38.23 | 23.38 |
July | 0.642443E+11 | 117906.51 | 01-JUL-05:01 | 29.33 | 23.52 | 0.921877E+10 | 10327.00 | 01-JUL-11:20 | 37.50 | 27.65 |
August | 0.618804E+11 | 109886.94 | 03-AUG-05:01 | 28.40 | 23.49 | 0.961377E+10 | 10326.89 | 05-AUG-11:20 | 34.23 | 26.11 |
September | 0.547609E+11 | 124218.17 | 27-SEP-05:01 | 23.08 | 20.68 | 0.908854E+10 | 10327.04 | 08-SEP-14:30 | 28.20 | 25.81 |
October | 0.501171E+11 | 139441.37 | 16-OCT-06:02 | 21.32 | 15.11 | 0.920289E+10 | 10327.14 | 25-OCT-14:00 | 29.10 | 18.46 |
November | 0.359313E+11 | 71468.39 | 11-NOV-09:02 | 20.20 | 15.91 | 0.882556E+10 | 10327.18 | 21-NOV-15:00 | 25.80 | 15.06 |
December | 0.257568E+11 | 32371.47 | 21-DEC-06:03 | 5.27 | 4.33 | 0.895100E+10 | 10327.18 | 01-DEC-15:20 | 23.03 | 13.47 |
Annual Sum or Average | 0.578712E+12 | 0.109232E+12 | ||||||||
Minimum of Months | 0.220117E+11 | 32371.47 | 4.93 | 4.33 | 0.826337E+10 | 10326.89 | 17.87 | 10.02 | ||
Maximum of Months | 0.698862E+11 | 157090.69 | 33.20 | 23.52 | 0.961377E+10 | 10327.48 | 38.23 | 27.65 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.559277E+10 | 7456.95 | 12-JAN-15:10 | 23.55 | 14.23 | 0.853036E+09 | 973.15 | 07-JAN-16:30 | 19.15 | 13.09 |
February | 0.636858E+10 | 8706.70 | 22-FEB-14:20 | 27.03 | 16.26 | 0.787237E+09 | 973.13 | 08-FEB-15:00 | 24.00 | 16.17 |
March | 0.913413E+10 | 21166.15 | 28-MAR-06:02 | 19.60 | 16.01 | 0.905559E+09 | 973.15 | 21-MAR-14:09 | 23.05 | 15.20 |
April | 0.109887E+11 | 25294.44 | 28-APR-05:01 | 27.22 | 17.14 | 0.856396E+09 | 973.19 | 15-APR-12:50 | 39.17 | 19.69 |
May | 0.129498E+11 | 24159.85 | 06-MAY-05:01 | 29.55 | 17.33 | 0.886632E+09 | 973.17 | 06-MAY-11:09 | 38.85 | 19.66 |
June | 0.129221E+11 | 22766.84 | 12-JUN-04:02 | 33.75 | 20.80 | 0.874349E+09 | 973.16 | 02-JUN-14:20 | 38.37 | 20.77 |
July | 0.129270E+11 | 20026.65 | 07-JUL-04:02 | 31.73 | 26.03 | 0.868659E+09 | 973.13 | 12-JUL-14:00 | 28.10 | 25.12 |
August | 0.128262E+11 | 18866.99 | 15-AUG-05:01 | 26.82 | 25.45 | 0.905878E+09 | 973.10 | 19-AUG-15:39 | 26.57 | 25.55 |
September | 0.119079E+11 | 22103.21 | 27-SEP-05:01 | 23.08 | 20.68 | 0.856393E+09 | 973.10 | 09-SEP-15:00 | 26.50 | 25.44 |
October | 0.123486E+11 | 24198.24 | 02-OCT-05:01 | 21.60 | 17.46 | 0.867351E+09 | 973.16 | 16-OCT-14:39 | 33.47 | 19.01 |
November | 0.100530E+11 | 21592.22 | 12-NOV-09:02 | 20.32 | 15.27 | 0.834088E+09 | 973.12 | 18-NOV-16:00 | 24.80 | 17.32 |
December | 0.685917E+10 | 8700.66 | 02-DEC-14:00 | 24.10 | 13.12 | 0.863177E+09 | 973.15 | 16-DEC-16:10 | 21.37 | 15.35 |
Annual Sum or Average | 0.124878E+12 | 0.103588E+11 | ||||||||
Minimum of Months | 0.559277E+10 | 7456.95 | 19.60 | 13.12 | 0.787237E+09 | 973.10 | 19.15 | 13.09 | ||
Maximum of Months | 0.129498E+11 | 25294.44 | 33.75 | 26.03 | 0.905878E+09 | 973.19 | 39.17 | 25.55 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.332665E+10 | 5210.35 | 12-JAN-15:10 | 23.55 | 14.23 | 0.830251E+09 | 973.13 | 25-JAN-15:00 | 22.30 | 13.54 |
February | 0.405117E+10 | 6570.08 | 22-FEB-15:10 | 27.00 | 16.13 | 0.777635E+09 | 973.13 | 07-FEB-15:00 | 25.30 | 15.80 |
March | 0.627405E+10 | 17121.02 | 29-MAR-06:02 | 21.15 | 17.30 | 0.904231E+09 | 973.12 | 04-MAR-16:00 | 25.90 | 15.51 |
April | 0.817904E+10 | 20746.71 | 28-APR-05:01 | 27.22 | 17.14 | 0.856347E+09 | 973.15 | 15-APR-12:39 | 38.93 | 19.61 |
May | 0.999844E+10 | 20170.42 | 06-MAY-05:01 | 29.55 | 17.33 | 0.886625E+09 | 973.14 | 06-MAY-11:09 | 38.85 | 19.66 |
June | 0.996668E+10 | 18199.29 | 12-JUN-04:02 | 33.75 | 20.80 | 0.874346E+09 | 973.11 | 02-JUN-14:09 | 38.28 | 20.72 |
July | 0.997548E+10 | 15551.65 | 07-JUL-05:01 | 31.52 | 25.90 | 0.868661E+09 | 973.09 | 12-JUL-14:00 | 28.10 | 25.12 |
August | 0.979473E+10 | 14775.70 | 09-AUG-05:01 | 29.90 | 25.20 | 0.905881E+09 | 973.09 | 19-AUG-15:30 | 26.70 | 25.63 |
September | 0.903096E+10 | 17368.85 | 27-SEP-05:01 | 23.08 | 20.68 | 0.856390E+09 | 973.08 | 07-SEP-14:09 | 27.02 | 25.39 |
October | 0.945057E+10 | 19511.10 | 02-OCT-05:01 | 21.60 | 17.46 | 0.867290E+09 | 973.14 | 16-OCT-14:39 | 33.47 | 19.01 |
November | 0.731766E+10 | 17554.89 | 12-NOV-09:02 | 20.32 | 15.27 | 0.833227E+09 | 973.14 | 18-NOV-16:40 | 25.13 | 17.31 |
December | 0.433253E+10 | 6533.68 | 02-DEC-14:00 | 24.10 | 13.12 | 0.853053E+09 | 973.14 | 04-DEC-15:00 | 22.10 | 14.53 |
Annual Sum or Average | 0.916980E+11 | 0.103139E+11 | ||||||||
Minimum of Months | 0.332665E+10 | 5210.35 | 20.32 | 13.12 | 0.777635E+09 | 973.08 | 22.10 | 13.54 | ||
Maximum of Months | 0.999844E+10 | 20746.71 | 33.75 | 25.90 | 0.905881E+09 | 973.15 | 38.93 | 25.63 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 | 7.49 | 0.00 | 0.00 | 01-JAN-00:10 | 7.83 | 7.49 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 | 7.84 | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 | 7.84 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 | 12.95 | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 | 12.95 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 | 16.76 | 0.00 | 0.00 | 01-APR-00:10 | 23.70 | 16.76 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 | 18.21 | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 | 18.21 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 | 22.57 | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 | 22.57 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 | 24.63 | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 | 24.63 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 | 26.26 | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 | 26.26 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 | 25.91 | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 | 25.91 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 | 21.84 | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 | 21.84 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 | 15.09 | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 | 15.09 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 | 9.10 | 0.00 | 0.00 | 01-DEC-00:10 | 12.50 | 9.10 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 7.83 | 7.49 | 0.00 | 0.00 | 7.83 | 7.49 | ||
Maximum of Months | 0.00 | 0.00 | 32.95 | 26.26 | 0.00 | 0.00 | 32.95 | 26.26 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.252952E+09 | 52039.96 | 01-JAN-08:61 | 8.17 |
February | 8265275.31 | 16675.34 | 02-FEB-07:03 | 7.12 |
March | 4546168.78 | 1446.86 | 11-MAR-07:06 | 23.87 |
April | 35052834.06 | 3221.95 | 16-APR-08:06 | 30.70 |
May | 39140663.43 | 3686.97 | 01-MAY-06:06 | 32.80 |
June | 33419306.51 | 3517.25 | 04-JUN-08:06 | 31.72 |
July | 28631863.19 | 3280.50 | 02-JUL-07:07 | 33.57 |
August | 26315994.60 | 2405.16 | 08-AUG-05:20 | 30.10 |
September | 27138381.75 | 1855.42 | 17-SEP-07:05 | 27.33 |
October | 11197599.47 | 1842.52 | 04-OCT-06:06 | 25.52 |
November | 594255.26 | 333.43 | 26-NOV-10:00 | 21.70 |
December | 18545600.51 | 30202.36 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 0.485799E+09 | |||
Minimum of Months | 594255.26 | 333.43 | 6.25 | |
Maximum of Months | 0.252952E+09 | 52039.96 | 33.57 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.555512E+09 | 184447.84 | 01-JAN-08:61 | 8.17 |
February | 31005746.44 | 93704.21 | 02-FEB-07:03 | 7.12 |
March | 8663428.02 | 7257.58 | 11-MAR-07:06 | 23.87 |
April | 0.172689E+09 | 21441.27 | 16-APR-08:06 | 30.70 |
May | 0.260622E+09 | 26316.25 | 01-MAY-06:06 | 32.80 |
June | 0.255718E+09 | 25160.29 | 12-JUN-05:06 | 34.12 |
July | 0.232156E+09 | 23776.14 | 02-JUL-07:06 | 33.57 |
August | 0.232032E+09 | 16104.64 | 08-AUG-05:06 | 30.10 |
September | 0.214837E+09 | 15781.67 | 24-SEP-08:08 | 28.43 |
October | 45532841.94 | 10077.67 | 01-OCT-08:06 | 25.28 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 47678535.64 | 137841.82 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 0.205645E+10 | |||
Minimum of Months | 0.00 | 0.00 | 6.25 | |
Maximum of Months | 0.555512E+09 | 184447.84 | 34.12 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 16166117.14 | 14321.26 | 02-JAN-07:03 | 6.78 |
February | 1370256.29 | 7064.03 | 11-FEB-07:03 | 9.97 |
March | 590838.87 | 581.56 | 12-MAR-08:04 | 21.93 |
April | 11828726.53 | 2073.16 | 27-APR-05:04 | 30.50 |
May | 14656329.53 | 2230.79 | 31-MAY-05:04 | 31.72 |
June | 13406261.48 | 2673.10 | 12-JUN-05:04 | 34.12 |
July | 11259055.44 | 2067.50 | 07-JUL-05:04 | 31.52 |
August | 12332878.33 | 1684.87 | 07-AUG-05:05 | 29.53 |
September | 14460207.24 | 1363.74 | 12-SEP-06:06 | 27.02 |
October | 1333600.00 | 956.68 | 04-OCT-05:04 | 25.07 |
November | 24268.37 | 202.24 | 12-NOV-09:04 | 20.32 |
December | 699070.92 | 4660.47 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 98127610.13 | |||
Minimum of Months | 24268.37 | 202.24 | 6.25 | |
Maximum of Months | 16166117.14 | 14321.26 | 34.12 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 72105338.33 | 23737.07 | 01-JAN-08:61 | 8.17 |
February | 6495831.13 | 14022.88 | 11-FEB-07:03 | 9.97 |
March | 590739.13 | 568.23 | 11-MAR-07:06 | 23.87 |
April | 10629623.76 | 1702.07 | 27-APR-05:04 | 30.50 |
May | 18137084.17 | 2098.41 | 01-MAY-05:05 | 32.45 |
June | 15625637.77 | 2230.02 | 12-JUN-05:04 | 34.12 |
July | 12023113.89 | 2263.33 | 02-JUL-07:06 | 33.57 |
August | 12943032.02 | 1622.84 | 08-AUG-05:06 | 30.10 |
September | 12033069.50 | 1044.60 | 17-SEP-07:05 | 27.33 |
October | 1288886.67 | 884.21 | 04-OCT-06:06 | 25.52 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 4129789.31 | 13264.51 | 23-DEC-07:03 | 6.25 |
Annual Sum or Average | 0.166002E+09 | |||
Minimum of Months | 0.00 | 0.00 | 6.25 | |
Maximum of Months | 72105338.33 | 23737.07 | 34.12 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 11428642.29 | 3104.20 | 05-JAN-08:04 | 6.10 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.73 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.55 |
April | 0.00 | 0.00 | 01-APR-00:10 | 23.70 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 30.53 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 28.05 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 32.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 29.32 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 28.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 26.58 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 17.72 |
December | 6230204.50 | 2512.94 | 31-DEC-08:04 | 6.52 |
Annual Sum or Average | 17658846.79 | |||
Minimum of Months | 0.00 | 0.00 | 6.10 | |
Maximum of Months | 11428642.29 | 3104.20 | 32.95 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.186041E+10 | 1543.42 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.169252E+10 | 1543.42 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.193008E+10 | 1543.42 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.182131E+10 | 1543.42 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.189524E+10 | 1543.42 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.186250E+10 | 1543.42 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.185405E+10 | 1543.42 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.193008E+10 | 1543.42 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.182131E+10 | 1543.42 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.186041E+10 | 1543.42 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.179919E+10 | 1543.42 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.185405E+10 | 1543.42 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.221812E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.169252E+10 | 1543.42 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.193008E+10 | 1543.42 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.168501E+11 | 17024.17 | 02-JAN-16:19 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.144641E+11 | 17024.17 | 01-FEB-16:40 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.151177E+11 | 17024.17 | 01-MAR-17:10 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.143033E+11 | 17024.17 | 22-APR-16:00 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.148196E+11 | 17024.17 | 31-MAY-16:30 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.142251E+11 | 14186.81 | 01-JUN-16:00 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.136309E+11 | 17024.17 | 18-JUL-08:09 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.144880E+11 | 17024.17 | 14-AUG-16:40 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.139765E+11 | 17024.17 | 05-SEP-08:09 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.153825E+11 | 17024.17 | 02-OCT-16:00 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.164069E+11 | 17024.17 | 01-NOV-16:30 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.170657E+11 | 17024.17 | 01-DEC-16:10 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.180730E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.136309E+11 | 14186.81 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.170657E+11 | 17024.17 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.191503E+10 | 1604.15 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.174243E+10 | 1604.15 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.198754E+10 | 1604.15 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.187525E+10 | 1604.15 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.195129E+10 | 1604.15 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.191792E+10 | 1604.15 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.190862E+10 | 1604.15 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.198754E+10 | 1604.15 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.187525E+10 | 1604.15 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.191503E+10 | 1604.15 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.185183E+10 | 1604.15 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.190862E+10 | 1604.15 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.228364E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.174243E+10 | 1604.15 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.198754E+10 | 1604.15 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.191503E+10 | 1604.15 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.174243E+10 | 1604.15 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.198754E+10 | 1604.15 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.187525E+10 | 1604.15 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.195129E+10 | 1604.15 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.191792E+10 | 1604.15 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.190862E+10 | 1604.15 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.198754E+10 | 1604.15 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.187525E+10 | 1604.15 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.191503E+10 | 1604.15 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.185183E+10 | 1604.15 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.190862E+10 | 1604.15 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.228364E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.174243E+10 | 1604.15 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.198754E+10 | 1604.15 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.124902E+09 | 104.63 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.113644E+09 | 104.63 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.129631E+09 | 104.63 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.122307E+09 | 104.63 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.127266E+09 | 104.63 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.125090E+09 | 104.63 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.124483E+09 | 104.63 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.129631E+09 | 104.63 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.122307E+09 | 104.63 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.124902E+09 | 104.63 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.120779E+09 | 104.63 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.124483E+09 | 104.63 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.148942E+10 | ||||
Minimum of Months | 0.113644E+09 | 104.63 | 0.00 | 0.00 | |
Maximum of Months | 0.129631E+09 | 104.63 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.186041E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191324E+09 |
February | 0.479114E+10 | 0.169252E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3245212.80 | 0.221367E+09 |
March | 0.548013E+10 | 0.193008E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 41957171.55 | 0.151703E+09 |
April | 0.518069E+10 | 0.182131E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.161858E+09 | 12446564.14 |
May | 0.536353E+10 | 0.189524E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314692E+09 | 6892365.27 |
June | 0.528933E+10 | 0.186250E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237011E+09 | 3476304.34 |
July | 0.525489E+10 | 0.185405E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276416E+09 | 2508213.09 |
August | 0.548013E+10 | 0.193008E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159443E+09 | 4019666.14 |
September | 0.518069E+10 | 0.182131E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 97655245.92 | 6509629.64 |
October | 0.524694E+10 | 0.186041E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48420333.08 | 14656028.76 |
November | 0.504819E+10 | 0.179919E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11483668.88 | 51565419.35 |
December | 0.525489E+10 | 0.185405E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 109509.42 | 0.187917E+09 |
Annual Sum or Average | 0.628175E+11 | 0.221812E+11 | 0.499918E+11 | 0.135229E+10 | 0.854385E+09 | ||||
Minimum of Months | 0.479114E+10 | 0.169252E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2508213.09 |
Maximum of Months | 0.548013E+10 | 0.193008E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314692E+09 | 0.221367E+09 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.168501E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.164896E+09 |
February | 0.201852E+11 | 0.144641E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2656752.44 | 0.192893E+09 |
March | 0.230879E+11 | 0.151177E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34227981.26 | 0.134569E+09 |
April | 0.218263E+11 | 0.143033E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133089E+09 | 10453101.00 |
May | 0.225967E+11 | 0.148196E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268468E+09 | 4772513.73 |
June | 0.222841E+11 | 0.142251E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201778E+09 | 2419716.46 |
July | 0.221389E+11 | 0.136309E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243999E+09 | 1218277.66 |
August | 0.230879E+11 | 0.144880E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141235E+09 | 1998431.75 |
September | 0.218263E+11 | 0.139765E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 82729354.18 | 3411162.56 |
October | 0.221054E+11 | 0.153825E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39749714.06 | 11452305.96 |
November | 0.212681E+11 | 0.164069E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9400821.30 | 43680222.07 |
December | 0.221389E+11 | 0.170657E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89648.64 | 0.161979E+09 |
Annual Sum or Average | 0.264651E+12 | 0.180730E+12 | 0.842987E+11 | 0.115742E+10 | 0.733744E+09 | ||||
Minimum of Months | 0.201852E+11 | 0.136309E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1218277.66 |
Maximum of Months | 0.230879E+11 | 0.170657E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268468E+09 | 0.192893E+09 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.191503E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 92976558.16 |
February | 0.190200E+10 | 0.174243E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1406147.06 | 0.106870E+09 |
March | 0.217552E+10 | 0.198754E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17582848.16 | 81258472.40 |
April | 0.205665E+10 | 0.187525E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 67277139.62 | 8435370.18 |
May | 0.212923E+10 | 0.195129E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126770E+09 | 4980123.10 |
June | 0.209978E+10 | 0.191792E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 96747077.03 | 1919548.30 |
July | 0.208610E+10 | 0.190862E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109846E+09 | 2080741.52 |
August | 0.217552E+10 | 0.198754E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63145349.34 | 3184971.53 |
September | 0.205665E+10 | 0.187525E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40575326.42 | 5784848.72 |
October | 0.208295E+10 | 0.191503E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20632591.33 | 8253570.70 |
November | 0.200405E+10 | 0.185183E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4976980.24 | 25706461.92 |
December | 0.208610E+10 | 0.190862E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47430.35 | 91266684.83 |
Annual Sum or Average | 0.249375E+11 | 0.228364E+11 | 0.529224E+11 | 0.549007E+09 | 0.432717E+09 | ||||
Minimum of Months | 0.190200E+10 | 0.174243E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1919548.30 |
Maximum of Months | 0.217552E+10 | 0.198754E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126770E+09 | 0.106870E+09 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.191503E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86962629.20 |
February | 0.190200E+10 | 0.174243E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1406343.70 | 99974853.51 |
March | 0.217552E+10 | 0.198754E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 17743248.13 | 72266189.67 |
April | 0.205665E+10 | 0.187525E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 68487527.65 | 6277477.92 |
May | 0.212923E+10 | 0.195129E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133188E+09 | 3040231.91 |
June | 0.209978E+10 | 0.191792E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101309E+09 | 1402806.98 |
July | 0.208610E+10 | 0.190862E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117465E+09 | 1030409.95 |
August | 0.217552E+10 | 0.198754E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 67416413.87 | 1783661.01 |
September | 0.205665E+10 | 0.187525E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 41495396.51 | 3158835.63 |
October | 0.208295E+10 | 0.191503E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 20722723.42 | 7156772.74 |
November | 0.200405E+10 | 0.185183E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 4976938.50 | 24263816.24 |
December | 0.208610E+10 | 0.190862E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 47411.15 | 86225591.67 |
Annual Sum or Average | 0.249375E+11 | 0.228364E+11 | 0.794328E+10 | 0.574257E+09 | 0.393543E+09 | ||||
Minimum of Months | 0.190200E+10 | 0.174243E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1030409.95 |
Maximum of Months | 0.217552E+10 | 0.198754E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.133188E+09 | 99974853.51 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.124902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129125E+10 |
February | 0.00 | 0.113644E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.771539E+09 |
March | 0.00 | 0.129631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71282971.59 | 0.321397E+09 |
April | 0.00 | 0.122307E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.632310E+09 | 31674098.48 |
May | 0.00 | 0.127266E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115050E+10 | 8560784.10 |
June | 0.00 | 0.125090E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104016E+10 | 15276694.80 |
July | 0.00 | 0.124483E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.602853E+09 | 10405580.80 |
August | 0.00 | 0.129631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.392264E+09 | 22063278.84 |
September | 0.00 | 0.122307E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260030E+09 | 25346143.80 |
October | 0.00 | 0.124902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 81799742.64 | 0.197420E+09 |
November | 0.00 | 0.120779E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.683814E+09 |
December | 0.00 | 0.124483E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129857E+10 |
Annual Sum or Average | 0.00 | 0.148942E+10 | 0.423120E+10 | 0.467731E+10 | |||||
Minimum of Months | 0.00 | 0.113644E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8560784.10 |
Maximum of Months | 0.00 | 0.129631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115050E+10 | 0.129857E+10 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 1543.42 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 543.32 | 15-JAN-19:10 |
February | 5888.82 | 01-FEB-15:09 | 1543.42 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 42.09 | 19-FEB-15:00 | 1038.94 | 09-FEB-21:10 |
March | 5888.82 | 01-MAR-15:09 | 1543.42 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 340.12 | 26-MAR-18:03 | 1606.02 | 24-MAR-24:00 |
April | 5888.82 | 01-APR-10:09 | 1543.42 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 650.78 | 02-APR-18:03 | 178.32 | 10-APR-05:00 |
May | 5888.82 | 01-MAY-14:09 | 1543.42 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1118.27 | 28-MAY-18:02 | 160.26 | 15-MAY-03:00 |
June | 5888.82 | 01-JUN-14:09 | 1543.42 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 925.57 | 17-JUN-21:03 | 164.53 | 18-JUN-04:10 |
July | 5888.82 | 01-JUL-10:09 | 1543.42 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 621.39 | 20-JUL-20:03 | 135.52 | 19-JUL-03:00 |
August | 5888.82 | 01-AUG-14:09 | 1543.42 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 405.87 | 15-AUG-20:03 | 174.35 | 15-AUG-24:00 |
September | 5888.82 | 01-SEP-14:09 | 1543.42 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 269.78 | 02-SEP-21:03 | 98.25 | 19-SEP-05:00 |
October | 5888.82 | 02-OCT-14:09 | 1543.42 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 255.56 | 03-OCT-15:00 | 263.69 | 12-OCT-03:00 |
November | 5888.82 | 01-NOV-14:09 | 1543.42 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 94.03 | 13-NOV-14:00 | 403.43 | 28-NOV-05:00 |
December | 5888.82 | 01-DEC-15:09 | 1543.42 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 9.65 | 28-DEC-14:00 | 919.98 | 29-DEC-24:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 1543.42 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.25 | |||||
Maximum of Months | 5888.82 | 1543.42 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 1118.27 | 1606.02 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 17024.17 | 02-JAN-16:19 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 447.21 | 15-JAN-19:40 |
February | 24809.68 | 01-FEB-15:09 | 17024.17 | 01-FEB-16:40 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 34.45 | 19-FEB-15:00 | 855.88 | 09-FEB-21:20 |
March | 24809.68 | 01-MAR-15:09 | 17024.17 | 01-MAR-17:10 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 277.01 | 26-MAR-18:03 | 1581.03 | 24-MAR-24:00 |
April | 24809.68 | 01-APR-10:09 | 17024.17 | 22-APR-16:00 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 534.35 | 02-APR-18:03 | 148.51 | 10-APR-05:00 |
May | 24809.68 | 01-MAY-14:09 | 17024.17 | 31-MAY-16:30 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 919.40 | 28-MAY-18:02 | 112.78 | 15-MAY-03:40 |
June | 24809.68 | 01-JUN-14:09 | 14186.81 | 01-JUN-16:00 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 764.25 | 17-JUN-21:03 | 130.34 | 18-JUN-05:00 |
July | 24809.68 | 01-JUL-10:09 | 17024.17 | 18-JUL-08:09 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 514.02 | 20-JUL-20:03 | 101.41 | 19-JUL-03:00 |
August | 24809.68 | 01-AUG-14:09 | 17024.17 | 14-AUG-16:40 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 337.03 | 15-AUG-20:03 | 120.65 | 15-AUG-24:00 |
September | 24809.68 | 01-SEP-14:09 | 17024.17 | 05-SEP-08:09 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 223.91 | 02-SEP-21:03 | 64.56 | 19-SEP-05:00 |
October | 24809.68 | 02-OCT-14:09 | 17024.17 | 02-OCT-16:00 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 209.20 | 03-OCT-15:00 | 212.73 | 12-OCT-03:00 |
November | 24809.68 | 01-NOV-14:09 | 17024.17 | 01-NOV-16:30 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 76.97 | 13-NOV-14:00 | 357.43 | 28-NOV-05:00 |
December | 24809.68 | 01-DEC-15:09 | 17024.17 | 01-DEC-16:10 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 7.90 | 28-DEC-14:00 | 833.64 | 29-DEC-24:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 14186.81 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.56 | |||||
Maximum of Months | 24809.68 | 17024.17 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 919.40 | 1581.03 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 1604.15 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 244.90 | 15-JAN-19:20 |
February | 2337.76 | 01-FEB-15:09 | 1604.15 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 18.24 | 19-FEB-15:00 | 459.94 | 09-FEB-21:10 |
March | 2337.76 | 01-MAR-15:09 | 1604.15 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 138.25 | 26-MAR-18:03 | 877.37 | 24-MAR-24:00 |
April | 2337.76 | 01-APR-10:09 | 1604.15 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 276.79 | 02-APR-18:03 | 85.87 | 04-APR-24:00 |
May | 2337.76 | 01-MAY-14:09 | 1604.15 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 480.78 | 28-MAY-18:02 | 92.46 | 15-MAY-03:00 |
June | 2337.76 | 01-JUN-14:09 | 1604.15 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 397.52 | 17-JUN-21:03 | 79.72 | 18-JUN-04:00 |
July | 2337.76 | 01-JUL-10:09 | 1604.15 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 265.06 | 20-JUL-20:03 | 69.05 | 19-JUL-03:00 |
August | 2337.76 | 01-AUG-14:09 | 1604.15 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 172.06 | 15-AUG-20:03 | 90.42 | 15-AUG-24:00 |
September | 2337.76 | 01-SEP-14:09 | 1604.15 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 114.68 | 02-SEP-21:03 | 57.26 | 19-SEP-05:00 |
October | 2337.76 | 02-OCT-14:09 | 1604.15 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 110.75 | 03-OCT-15:00 | 132.18 | 12-OCT-03:00 |
November | 2337.76 | 01-NOV-14:09 | 1604.15 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 40.75 | 13-NOV-14:00 | 213.46 | 28-NOV-05:00 |
December | 2337.76 | 01-DEC-15:09 | 1604.15 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4.18 | 28-DEC-14:00 | 437.22 | 29-DEC-24:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 1604.15 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.26 | |||||
Maximum of Months | 2337.76 | 1604.15 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 480.78 | 877.37 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 1604.15 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 220.36 | 15-JAN-19:30 |
February | 2337.76 | 01-FEB-15:09 | 1604.15 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 18.24 | 19-FEB-15:00 | 419.42 | 09-FEB-21:10 |
March | 2337.76 | 01-MAR-15:09 | 1604.15 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 140.85 | 26-MAR-18:03 | 782.71 | 24-MAR-24:00 |
April | 2337.76 | 01-APR-10:09 | 1604.15 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 278.53 | 02-APR-18:03 | 74.77 | 10-APR-05:00 |
May | 2337.76 | 01-MAY-14:09 | 1604.15 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 482.04 | 28-MAY-18:02 | 68.37 | 15-MAY-03:00 |
June | 2337.76 | 01-JUN-14:09 | 1604.15 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 399.62 | 17-JUN-21:03 | 64.77 | 18-JUN-05:00 |
July | 2337.76 | 01-JUL-10:09 | 1604.15 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 267.32 | 20-JUL-20:03 | 54.08 | 19-JUL-03:00 |
August | 2337.76 | 01-AUG-14:09 | 1604.15 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 174.07 | 15-AUG-20:03 | 76.90 | 15-AUG-24:00 |
September | 2337.76 | 01-SEP-14:09 | 1604.15 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 115.77 | 02-SEP-21:03 | 45.58 | 19-SEP-05:00 |
October | 2337.76 | 02-OCT-14:09 | 1604.15 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 110.75 | 03-OCT-15:00 | 114.46 | 12-OCT-03:00 |
November | 2337.76 | 01-NOV-14:09 | 1604.15 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 40.75 | 13-NOV-14:00 | 198.11 | 28-NOV-05:00 |
December | 2337.76 | 01-DEC-15:09 | 1604.15 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 4.18 | 28-DEC-14:00 | 404.78 | 29-DEC-24:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 1604.15 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.58 | |||||
Maximum of Months | 2337.76 | 1604.15 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 482.04 | 782.71 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 104.63 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4184.98 | 27-JAN-12:01 |
February | 0.00 | 01-FEB-00:10 | 104.63 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3106.20 | 09-FEB-12:01 |
March | 0.00 | 01-MAR-00:10 | 104.63 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1118.68 | 28-MAR-11:02 | 1925.57 | 16-MAR-07:01 |
April | 0.00 | 01-APR-00:10 | 104.63 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3422.49 | 16-APR-11:01 | 1138.61 | 05-APR-07:01 |
May | 0.00 | 01-MAY-00:10 | 104.63 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5060.41 | 01-MAY-11:01 | 681.66 | 31-MAY-16:53 |
June | 0.00 | 01-JUN-00:10 | 104.63 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5005.37 | 12-JUN-11:01 | 1188.91 | 27-JUN-11:02 |
July | 0.00 | 01-JUL-00:10 | 104.63 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3322.96 | 07-JUL-11:01 | 776.04 | 18-JUL-11:03 |
August | 0.00 | 01-AUG-00:10 | 104.63 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1769.05 | 05-AUG-11:02 | 656.18 | 16-AUG-07:02 |
September | 0.00 | 01-SEP-00:10 | 104.63 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1222.49 | 11-SEP-11:02 | 653.36 | 19-SEP-07:02 |
October | 0.00 | 01-OCT-00:10 | 104.63 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1293.25 | 02-OCT-11:02 | 1949.25 | 31-OCT-07:01 |
November | 0.00 | 01-NOV-00:10 | 104.63 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2757.76 | 30-NOV-12:02 |
December | 0.00 | 01-DEC-00:10 | 104.63 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5734.05 | 21-DEC-12:01 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 104.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 653.36 | ||||
Maximum of Months | 0.00 | 104.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5060.41 | 5734.05 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4799.40 | 14-JAN-16:00 | 5888.82 | 1543.42 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.51 |
February | 7377.37 | 24-FEB-15:50 | 5888.82 | 1543.42 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 30.63 | 0.00 |
March | 33777.07 | 29-MAR-06:02 | 3680.51 | 1714.91 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.24 |
April | 39443.55 | 28-APR-05:01 | 0.00 | 787.02 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.46 | 0.00 |
May | 39137.52 | 06-MAY-05:01 | 0.00 | 787.02 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 16.18 | 0.00 |
June | 36671.85 | 07-JUN-05:01 | 0.00 | 787.02 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 55.12 | 0.00 |
July | 32460.98 | 07-JUL-05:01 | 0.00 | 688.64 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.81 | 0.00 |
August | 30839.71 | 09-AUG-05:01 | 0.00 | 688.64 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.95 | 0.00 |
September | 34305.99 | 27-SEP-05:01 | 0.00 | 688.64 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.27 |
October | 37090.91 | 02-OCT-05:01 | 0.00 | 688.64 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.35 |
November | 21702.27 | 11-NOV-09:02 | 3680.51 | 857.46 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6022.66 | 01-DEC-15:10 | 5888.82 | 1543.42 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3.37 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4799.40 | 0.00 | 688.64 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 39443.55 | 5888.82 | 1714.91 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 55.12 | 42.51 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 33817.60 | 05-JAN-07:05 | 12404.84 | 15132.60 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 33267.09 | 23-FEB-15:10 | 24809.68 | 12768.13 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 12.14 | 0.00 |
March | 134685.95 | 13-MAR-06:02 | 15506.05 | 18915.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.00 |
April | 157090.69 | 08-APR-06:02 | 15506.05 | 9457.87 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.88 |
May | 151957.88 | 06-MAY-05:01 | 0.00 | 7566.30 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 16.62 | 0.00 |
June | 136389.08 | 07-JUN-05:01 | 0.00 | 7566.30 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 50.51 | 0.00 |
July | 117906.51 | 01-JUL-05:01 | 0.00 | 6620.51 | 5428.04 | 0.00 | 0.00 | 0.00 | 0.00 | 21.92 | 0.00 |
August | 109886.94 | 03-AUG-05:01 | 0.00 | 7566.30 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 11.76 | 0.00 |
September | 124218.17 | 27-SEP-05:01 | 0.00 | 6620.51 | 7237.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.90 |
October | 139441.37 | 16-OCT-06:02 | 15506.05 | 18915.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.24 |
November | 71468.39 | 11-NOV-09:02 | 15506.05 | 7093.40 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 32371.47 | 21-DEC-06:03 | 0.00 | 2837.36 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.12 |
Annual Sum or Average | |||||||||||
Minimum of Months | 32371.47 | 0.00 | 2837.36 | 3101.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 157090.69 | 24809.68 | 18915.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 50.51 | 44.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7456.95 | 12-JAN-15:10 | 2337.76 | 1604.15 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.76 |
February | 8706.70 | 22-FEB-14:20 | 2045.54 | 1604.15 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 8.15 | 0.00 |
March | 21166.15 | 28-MAR-06:02 | 1461.10 | 1782.39 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 25294.44 | 28-APR-05:01 | 0.00 | 712.96 | 5192.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 |
May | 24159.85 | 06-MAY-05:01 | 0.00 | 712.96 | 3894.52 | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 0.00 |
June | 22766.84 | 12-JUN-04:02 | 0.00 | 534.72 | 3894.52 | 0.00 | 0.00 | 0.00 | 0.00 | 52.35 | 0.00 |
July | 20026.65 | 07-JUL-04:02 | 0.00 | 445.60 | 3245.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 18866.99 | 15-AUG-05:01 | 0.00 | 623.84 | 4543.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.03 |
September | 22103.21 | 27-SEP-05:01 | 0.00 | 623.84 | 4543.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.69 |
October | 24198.24 | 02-OCT-05:01 | 0.00 | 623.84 | 4543.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 |
November | 21592.22 | 12-NOV-09:02 | 1461.10 | 891.19 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.59 |
December | 8700.66 | 02-DEC-14:00 | 2337.76 | 1604.15 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 7456.95 | 0.00 | 445.60 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 25294.44 | 2337.76 | 1782.39 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 52.35 | 15.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5210.35 | 12-JAN-15:10 | 2337.76 | 1604.15 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.76 |
February | 6570.08 | 22-FEB-15:10 | 2337.76 | 1604.15 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 10.89 | 0.00 |
March | 17121.02 | 29-MAR-06:02 | 1461.10 | 1782.39 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.86 |
April | 20746.71 | 28-APR-05:01 | 0.00 | 712.96 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.13 | 0.00 |
May | 20170.42 | 06-MAY-05:01 | 0.00 | 712.96 | 584.54 | 0.00 | 0.00 | 0.00 | 0.00 | 6.74 | 0.00 |
June | 18199.29 | 12-JUN-04:02 | 0.00 | 534.72 | 584.54 | 0.00 | 0.00 | 0.00 | 0.00 | 57.12 | 0.00 |
July | 15551.65 | 07-JUL-05:01 | 0.00 | 623.84 | 681.96 | 0.00 | 0.00 | 0.00 | 0.00 | 1.22 | 0.00 |
August | 14775.70 | 09-AUG-05:01 | 0.00 | 623.84 | 681.96 | 0.00 | 0.00 | 0.00 | 0.00 | 6.73 | 0.00 |
September | 17368.85 | 27-SEP-05:01 | 0.00 | 623.84 | 681.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.58 |
October | 19511.10 | 02-OCT-05:01 | 0.00 | 623.84 | 681.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 |
November | 17554.89 | 12-NOV-09:02 | 1461.10 | 891.19 | 730.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.40 |
December | 6533.68 | 02-DEC-14:00 | 2337.76 | 1604.15 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.34 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 5210.35 | 0.00 | 534.72 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20746.71 | 2337.76 | 1782.39 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 57.12 | 14.40 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 01-APR-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.64 | 0.00 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.62 | 0.00 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 0.00 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.18 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.46 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 5.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.62 | 5.46 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.590429E+11 | 53523.88 | 14-JAN-17:49 | 0.122770E+11 | 111459.96 | 02-JAN-07:10 |
February | 0.597469E+11 | 60658.39 | 24-FEB-16:40 | 0.718322E+10 | 54643.97 | 02-FEB-07:10 |
March | 0.809882E+11 | 73520.37 | 28-MAR-16:40 | 0.749832E+10 | 4890.30 | 01-MAR-12:30 |
April | 0.970847E+11 | 89650.38 | 26-APR-14:00 | 0.700831E+10 | 4838.51 | 03-APR-11:09 |
May | 0.122036E+12 | 105009.65 | 30-MAY-14:00 | 0.702620E+10 | 4787.60 | 01-MAY-11:50 |
June | 0.127502E+12 | 115502.61 | 10-JUN-15:00 | 0.665777E+10 | 4740.15 | 01-JUN-11:09 |
July | 0.128510E+12 | 110273.15 | 01-JUL-14:50 | 0.676921E+10 | 4712.31 | 03-JUL-11:30 |
August | 0.127166E+12 | 101272.50 | 07-AUG-14:00 | 0.686477E+10 | 4734.69 | 31-AUG-11:50 |
September | 0.110386E+12 | 95178.51 | 14-SEP-15:50 | 0.676673E+10 | 4776.80 | 29-SEP-11:30 |
October | 0.939144E+11 | 85239.12 | 03-OCT-14:39 | 0.718039E+10 | 4833.68 | 31-OCT-11:09 |
November | 0.749821E+11 | 68011.29 | 08-NOV-16:19 | 0.715309E+10 | 4882.72 | 30-NOV-12:39 |
December | 0.623452E+11 | 55393.52 | 28-DEC-15:30 | 0.803725E+10 | 74927.03 | 23-DEC-07:10 |
Annual Sum or Average | 0.114370E+13 | 0.904223E+11 | ||||
Minimum of Months | 0.590429E+11 | 53523.88 | 0.665777E+10 | 4712.31 | ||
Maximum of Months | 0.128510E+12 | 115502.61 | 0.122770E+11 | 111459.96 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.226654E+11 | 0.420188E+10 | 0.164409E+11 | 0.00 | 0.114873E+11 | 0.00 | 0.00 | 0.424730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.197551E+11 | 0.360691E+10 | 0.149157E+11 | 0.00 | 0.103136E+11 | 0.00 | 0.00 | 0.111555E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.211525E+11 | 0.368819E+10 | 0.168545E+11 | 0.00 | 0.115655E+11 | 0.00 | 0.00 | 0.277275E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.199974E+11 | 0.327056E+10 | 0.160165E+11 | 0.00 | 0.114518E+11 | 0.00 | 0.00 | 0.463483E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.207447E+11 | 0.311720E+10 | 0.166477E+11 | 0.00 | 0.135604E+11 | 0.00 | 0.00 | 0.679664E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.200485E+11 | 0.287541E+10 | 0.162772E+11 | 0.00 | 0.145684E+11 | 0.00 | 0.00 | 0.737321E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.194266E+11 | 0.304805E+10 | 0.163871E+11 | 0.00 | 0.150238E+11 | 0.00 | 0.00 | 0.746246E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.205228E+11 | 0.325945E+10 | 0.168545E+11 | 0.00 | 0.147933E+11 | 0.00 | 0.00 | 0.717364E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.196706E+11 | 0.344047E+10 | 0.160165E+11 | 0.00 | 0.124954E+11 | 0.00 | 0.00 | 0.587627E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.211979E+11 | 0.386600E+10 | 0.164409E+11 | 0.00 | 0.115121E+11 | 0.00 | 0.00 | 0.408975E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.220305E+11 | 0.399961E+10 | 0.159174E+11 | 0.00 | 0.109439E+11 | 0.00 | 0.00 | 0.220906E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.228615E+11 | 0.429474E+10 | 0.163871E+11 | 0.00 | 0.113935E+11 | 0.00 | 0.00 | 0.740845E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.250074E+12 | 0.426685E+11 | 0.195156E+12 | 0.149109E+12 | 0.00 | 0.506697E+12 | |||||||
Minimum of Months | 0.194266E+11 | 0.287541E+10 | 0.149157E+11 | 0.00 | 0.103136E+11 | 0.00 | 0.00 | 0.424730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.228615E+11 | 0.429474E+10 | 0.168545E+11 | 0.00 | 0.150238E+11 | 0.00 | 0.00 | 0.746246E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.463609E+10 | 0.00 | 0.764095E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.317393E+09 | 0.00 | 0.686583E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.749832E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.700831E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.702620E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.665777E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.676921E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.686477E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.676673E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.718039E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.715309E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.464890E+09 | 0.00 | 0.757236E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.541838E+10 | 0.850039E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.665777E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.463609E+10 | 0.00 | 0.764095E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 21880.52 | 02-JAN-16:19 | 3292.90 | 01-JAN-06:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 10113.20 | 02-JAN-07:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 21880.52 | 01-FEB-16:40 | 3292.90 | 01-FEB-06:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 8497.16 | 02-FEB-07:10 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 21880.52 | 01-MAR-17:10 | 3292.90 | 01-MAR-06:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 10293.80 | 11-MAR-07:10 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 21880.52 | 22-APR-16:00 | 3292.90 | 01-APR-05:10 | 10771.04 | 01-APR-09:09 | 0.00 | 11072.66 | 17-APR-06:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 21880.52 | 31-MAY-16:30 | 3292.90 | 01-MAY-05:10 | 10771.04 | 01-MAY-08:09 | 0.00 | 12165.43 | 30-MAY-14:00 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 19043.16 | 01-JUN-16:00 | 3292.90 | 01-JUN-05:10 | 10771.04 | 01-JUN-08:09 | 0.00 | 13800.14 | 14-JUN-06:10 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 21880.52 | 18-JUL-08:09 | 3292.90 | 01-JUL-05:10 | 10771.04 | 01-JUL-09:09 | 0.00 | 14236.99 | 01-JUL-14:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 21880.52 | 14-AUG-16:40 | 3292.90 | 01-AUG-05:10 | 10771.04 | 01-AUG-08:09 | 0.00 | 14169.45 | 27-AUG-08:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 21880.52 | 05-SEP-08:09 | 3292.90 | 01-SEP-05:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 13233.98 | 03-SEP-08:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 21880.52 | 02-OCT-16:00 | 3292.90 | 01-OCT-05:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 11155.12 | 04-OCT-06:10 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 21880.52 | 01-NOV-16:30 | 3292.90 | 01-NOV-05:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 7562.07 | 11-NOV-09:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 21880.52 | 01-DEC-16:10 | 3292.90 | 01-DEC-06:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 9061.91 | 23-DEC-07:10 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 19043.16 | 3292.90 | 10771.04 | 0.00 | 7562.07 | 0.00 | 0.00 | |||||
Maximum of Months | 21880.52 | 3292.90 | 10771.04 | 0.00 | 14236.99 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 14532.47 | 12-JAN-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 23636.50 | 24-FEB-15:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 37656.77 | 28-MAR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 51947.21 | 18-APR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 64448.71 | 30-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 73348.86 | 10-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 70479.47 | 01-JUL-14:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 63264.30 | 07-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 56460.90 | 14-SEP-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 47989.46 | 03-OCT-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 30249.66 | 09-NOV-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 17225.91 | 28-DEC-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 14532.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 73348.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 53523.88 | 14-JAN-17:49 | 21880.52 | 10771.04 | 3292.90 | 0.00 | 7085.16 | 0.00 | 0.00 | 10494.26 | 0.00 |
February | 60658.39 | 24-FEB-16:40 | 20461.84 | 10771.04 | 0.00 | 0.00 | 7085.16 | 0.00 | 0.00 | 22340.35 | 0.00 |
March | 73520.37 | 28-MAR-16:40 | 20461.84 | 10771.04 | 0.00 | 0.00 | 7085.16 | 0.00 | 0.00 | 35202.33 | 0.00 |
April | 89650.38 | 26-APR-14:00 | 17624.48 | 10771.04 | 0.00 | 0.00 | 9402.23 | 0.00 | 0.00 | 51852.64 | 0.00 |
May | 105009.65 | 30-MAY-14:00 | 17624.48 | 10771.04 | 0.00 | 0.00 | 12165.43 | 0.00 | 0.00 | 64448.71 | 0.00 |
June | 115502.61 | 10-JUN-15:00 | 17624.48 | 10771.04 | 0.00 | 0.00 | 13758.23 | 0.00 | 0.00 | 73348.86 | 0.00 |
July | 110273.15 | 01-JUL-14:50 | 14787.11 | 10771.04 | 0.00 | 0.00 | 14235.52 | 0.00 | 0.00 | 70479.47 | 0.00 |
August | 101272.50 | 07-AUG-14:00 | 14787.11 | 10771.04 | 0.00 | 0.00 | 12450.05 | 0.00 | 0.00 | 63264.30 | 0.00 |
September | 95178.51 | 14-SEP-15:50 | 17624.48 | 10771.04 | 0.00 | 0.00 | 11162.80 | 0.00 | 0.00 | 55620.19 | 0.00 |
October | 85239.12 | 03-OCT-14:39 | 17624.48 | 10771.04 | 0.00 | 0.00 | 8908.62 | 0.00 | 0.00 | 47934.98 | 0.00 |
November | 68011.29 | 08-NOV-16:19 | 21880.52 | 10771.04 | 0.00 | 0.00 | 7085.16 | 0.00 | 0.00 | 28274.58 | 0.00 |
December | 55393.52 | 28-DEC-15:30 | 20461.84 | 10771.04 | 0.00 | 0.00 | 7085.16 | 0.00 | 0.00 | 17075.48 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 53523.88 | 14787.11 | 10771.04 | 0.00 | 0.00 | 7085.16 | 0.00 | 0.00 | 10494.26 | 0.00 | |
Maximum of Months | 115502.61 | 21880.52 | 10771.04 | 3292.90 | 0.00 | 14235.52 | 0.00 | 0.00 | 73348.86 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 109597.96 | 02-JAN-07:10 | 0.00 | 4919.97 | 17-JAN-12:20 | 0.00 |
February | 0.00 | 0.00 | 50112.56 | 02-FEB-07:10 | 0.00 | 4916.07 | 01-FEB-12:09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 4890.30 | 01-MAR-12:30 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 4838.51 | 03-APR-11:09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 4787.60 | 01-MAY-11:50 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 4740.15 | 01-JUN-11:09 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 4712.31 | 03-JUL-11:30 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 4734.69 | 31-AUG-11:50 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 4776.80 | 29-SEP-11:30 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 4833.68 | 31-OCT-11:09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 4882.72 | 30-NOV-12:39 | 0.00 |
December | 0.00 | 0.00 | 70360.45 | 23-DEC-07:10 | 0.00 | 4913.08 | 29-DEC-12:30 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4712.31 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 109597.96 | 0.00 | 4919.97 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.18 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 26.17 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.50 | 26.17 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 26.18 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 28.44 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 28.42 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 28.45 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 28.42 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 28.38 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 1.83 | 28.42 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 28.45 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 28.43 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.17 | 28.43 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 28.43 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 30.83 | 14.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 2.17 | 15.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 17.00 | 14.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 50.00 | 14.70 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 30.83 | 15.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 404.33 | 22.98 | 3.83 | 21.19 | 3.83 | 21.19 |
February | 250.00 | 23.39 | 7.50 | 23.89 | 0.00 | 0.00 |
March | 58.67 | 23.71 | 140.17 | 23.89 | 0.00 | 0.00 |
April | 0.50 | 23.81 | 333.33 | 23.89 | 0.00 | 0.00 |
May | 2.67 | 23.98 | 418.00 | 23.89 | 2.67 | 23.98 |
June | 14.17 | 23.94 | 408.00 | 23.89 | 14.17 | 23.94 |
July | 26.83 | 23.96 | 415.00 | 23.89 | 26.83 | 23.96 |
August | 23.33 | 23.96 | 422.00 | 23.89 | 23.33 | 23.96 |
September | 39.00 | 23.92 | 405.00 | 23.89 | 39.00 | 23.92 |
October | 0.83 | 23.94 | 362.17 | 23.89 | 0.83 | 23.94 |
November | 75.67 | 23.63 | 70.00 | 23.89 | 0.00 | 0.00 |
December | 376.83 | 23.35 | 0.17 | 21.32 | 0.17 | 21.32 |
Annual Sum or Average | 1272.83 | 23.32 | 2985.17 | 23.89 | 110.83 | 23.84 |
Minimum of Months | 0.50 | 22.98 | 0.17 | 21.19 | 0.00 | 0.00 |
Maximum of Months | 404.33 | 23.98 | 422.00 | 23.89 | 39.00 | 23.98 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 342.00 | 22.76 | 0.83 | 21.24 | 0.83 | 21.24 |
February | 124.33 | 22.84 | 46.83 | 23.89 | 0.00 | 0.00 |
March | 23.33 | 23.31 | 233.33 | 23.89 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 361.83 | 23.89 | 0.00 | 0.00 |
May | 8.17 | 23.93 | 418.00 | 23.89 | 8.17 | 23.93 |
June | 57.67 | 23.91 | 408.00 | 23.89 | 57.67 | 23.91 |
July | 169.50 | 23.90 | 415.00 | 23.90 | 169.50 | 23.90 |
August | 237.33 | 23.90 | 422.00 | 23.89 | 237.33 | 23.90 |
September | 160.67 | 23.90 | 405.00 | 23.89 | 160.67 | 23.90 |
October | 6.50 | 23.89 | 391.50 | 23.89 | 6.50 | 23.89 |
November | 41.67 | 23.06 | 165.17 | 23.89 | 0.00 | 0.00 |
December | 232.00 | 22.87 | 1.67 | 23.88 | 0.00 | 0.00 |
Annual Sum or Average | 1403.17 | 23.32 | 3269.17 | 23.89 | 640.67 | 23.90 |
Minimum of Months | 0.00 | 0.00 | 0.83 | 21.24 | 0.00 | 0.00 |
Maximum of Months | 342.00 | 23.93 | 422.00 | 23.90 | 237.33 | 23.93 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 143.67 | 22.78 | 52.50 | 23.86 | 0.50 | 21.20 |
February | 56.67 | 22.86 | 167.67 | 23.89 | 0.00 | 0.00 |
March | 12.33 | 23.72 | 321.17 | 23.89 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 387.50 | 23.89 | 0.00 | 0.00 |
May | 1.67 | 23.99 | 418.00 | 23.89 | 1.67 | 23.99 |
June | 9.67 | 23.94 | 408.00 | 23.89 | 9.67 | 23.94 |
July | 18.67 | 23.96 | 415.00 | 23.89 | 18.67 | 23.96 |
August | 19.83 | 23.94 | 422.00 | 23.89 | 19.83 | 23.94 |
September | 20.67 | 23.92 | 405.00 | 23.89 | 20.67 | 23.92 |
October | 0.67 | 23.97 | 413.00 | 23.89 | 0.67 | 23.97 |
November | 6.50 | 23.39 | 335.67 | 23.89 | 0.00 | 0.00 |
December | 84.83 | 23.04 | 128.50 | 23.89 | 0.00 | 0.00 |
Annual Sum or Average | 375.17 | 23.11 | 3874.00 | 23.89 | 71.67 | 23.92 |
Minimum of Months | 0.00 | 0.00 | 52.50 | 23.86 | 0.00 | 0.00 |
Maximum of Months | 143.67 | 23.99 | 422.00 | 23.89 | 20.67 | 23.99 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 222.67 | 22.45 | 20.83 | 23.65 | 1.83 | 21.15 |
February | 102.83 | 22.60 | 118.83 | 23.89 | 0.00 | 0.00 |
March | 30.83 | 23.29 | 278.17 | 23.89 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 365.33 | 23.89 | 0.00 | 0.00 |
May | 5.17 | 23.92 | 418.00 | 23.89 | 5.17 | 23.92 |
June | 21.33 | 23.92 | 408.00 | 23.89 | 21.33 | 23.92 |
July | 38.33 | 23.93 | 415.00 | 23.89 | 38.33 | 23.93 |
August | 42.67 | 23.93 | 422.00 | 23.89 | 42.67 | 23.93 |
September | 59.67 | 23.91 | 405.00 | 23.89 | 59.67 | 23.91 |
October | 4.67 | 23.90 | 405.17 | 23.89 | 4.67 | 23.90 |
November | 17.67 | 23.09 | 306.00 | 23.89 | 0.00 | 0.00 |
December | 133.83 | 22.67 | 76.50 | 23.88 | 0.17 | 21.25 |
Annual Sum or Average | 679.67 | 22.94 | 3638.83 | 23.89 | 173.83 | 23.89 |
Minimum of Months | 0.00 | 0.00 | 20.83 | 23.65 | 0.00 | 0.00 |
Maximum of Months | 222.67 | 23.93 | 422.00 | 23.89 | 59.67 | 23.93 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.97527 | 47.33026 | 0.02679 | 6.31585 |
February | 376.00000 | 23.53394 | 46.75152 | 0.21486 | 6.68216 |
March | 422.00000 | 23.86370 | 45.26458 | 0.37298 | 8.03639 |
April | 405.00000 | 23.90948 | 44.67339 | 0.47617 | 9.81819 |
May | 418.00000 | 23.91395 | 49.93398 | -0.2699 | 6.60172 |
June | 408.00000 | 23.91461 | 53.25135 | -0.2322 | 6.22857 |
July | 415.00000 | 23.91626 | 56.64179 | -0.2149 | 6.06119 |
August | 422.00000 | 23.91526 | 57.13715 | -0.2278 | 6.15229 |
September | 405.00000 | 23.91484 | 56.20277 | -0.2751 | 6.64583 |
October | 414.00000 | 23.90664 | 47.89861 | 0.47955 | 9.86448 |
November | 399.00000 | 23.83529 | 45.12684 | 0.35063 | 7.70942 |
December | 415.00000 | 23.37630 | 44.87154 | 0.14287 | 6.24856 |
Annual Sum or Average | 4913.00000 | 23.74910 | 49.62432 | 0.06830 | 7.19562 |
Minimum of Months | 376.00000 | 22.97527 | 44.67339 | -0.2751 | 6.06119 |
Maximum of Months | 422.00000 | 23.91626 | 57.13715 | 0.47955 | 9.86448 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.93166 | 43.20265 | 0.07910 | 6.42097 |
February | 376.00000 | 23.51708 | 43.49637 | 0.27636 | 7.27468 |
March | 422.00000 | 23.85409 | 42.67903 | 0.42043 | 8.82853 |
April | 405.00000 | 23.90856 | 42.66708 | 0.50989 | 10.53633 |
May | 418.00000 | 23.91395 | 50.23577 | -0.2307 | 6.20996 |
June | 408.00000 | 23.91476 | 55.51444 | -0.1943 | 5.89015 |
July | 415.00000 | 23.91634 | 61.22949 | -0.1867 | 5.80461 |
August | 422.00000 | 23.91567 | 62.62376 | -0.1965 | 5.86542 |
September | 405.00000 | 23.91498 | 60.63802 | -0.2353 | 6.21850 |
October | 414.00000 | 23.90049 | 48.13660 | 0.50857 | 10.47552 |
November | 399.00000 | 23.78964 | 42.78599 | 0.38404 | 8.26794 |
December | 415.00000 | 23.29604 | 41.19942 | 0.18620 | 6.59949 |
Annual Sum or Average | 4913.00000 | 23.73229 | 49.59770 | 0.10793 | 7.36058 |
Minimum of Months | 376.00000 | 22.93166 | 41.19942 | -0.2353 | 5.80461 |
Maximum of Months | 422.00000 | 23.91634 | 62.62376 | 0.50989 | 10.53633 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.47348 | 39.01513 | 0.25369 | 7.44370 |
February | 376.00000 | 23.71856 | 39.55723 | 0.37057 | 8.41815 |
March | 422.00000 | 23.89119 | 39.60870 | 0.47674 | 9.90478 |
April | 405.00000 | 23.91106 | 40.42151 | 0.55384 | 11.54347 |
May | 418.00000 | 23.91292 | 46.61237 | -0.1734 | 5.74676 |
June | 408.00000 | 23.91309 | 50.46628 | -0.1397 | 5.54336 |
July | 415.00000 | 23.91416 | 54.16601 | -0.1235 | 5.43201 |
August | 422.00000 | 23.91345 | 54.64106 | -0.1315 | 5.45536 |
September | 405.00000 | 23.91320 | 52.61304 | -0.1581 | 5.64864 |
October | 414.00000 | 23.91063 | 42.44580 | 0.59497 | 12.52827 |
November | 399.00000 | 23.88661 | 37.99854 | 0.50460 | 10.48311 |
December | 415.00000 | 23.69778 | 36.61020 | 0.33899 | 7.95690 |
Annual Sum or Average | 4913.00000 | 23.83868 | 44.56717 | 0.19499 | 7.99540 |
Minimum of Months | 376.00000 | 23.47348 | 36.61020 | -0.1734 | 5.43201 |
Maximum of Months | 422.00000 | 23.91416 | 54.64106 | 0.59497 | 12.52827 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.09021 | 41.77003 | 0.14998 | 6.98553 |
February | 376.00000 | 23.51395 | 42.10473 | 0.30430 | 7.85174 |
March | 422.00000 | 23.84309 | 41.33004 | 0.43972 | 9.27294 |
April | 405.00000 | 23.90838 | 41.32962 | 0.52419 | 10.87223 |
May | 418.00000 | 23.91313 | 48.03573 | -0.2117 | 6.04765 |
June | 408.00000 | 23.91372 | 52.40056 | -0.1761 | 5.77367 |
July | 415.00000 | 23.91514 | 56.63979 | -0.1549 | 5.60870 |
August | 422.00000 | 23.91444 | 57.35468 | -0.1621 | 5.63668 |
September | 405.00000 | 23.91396 | 55.40844 | -0.1889 | 5.85718 |
October | 414.00000 | 23.90781 | 43.94552 | 0.56982 | 11.90340 |
November | 399.00000 | 23.84878 | 39.41334 | 0.46854 | 9.80305 |
December | 415.00000 | 23.47185 | 38.89557 | 0.26707 | 7.44342 |
Annual Sum or Average | 4913.00000 | 23.76428 | 46.60552 | 0.15032 | 7.74499 |
Minimum of Months | 376.00000 | 23.09021 | 38.89557 | -0.2117 | 5.60870 |
Maximum of Months | 422.00000 | 23.91514 | 57.35468 | 0.56982 | 11.90340 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.136538E+10 | 0.376347E+09 | 150.88 | 0.110312E+10 | 0.262256E+09 | 0.00 | 0.37 | 14-JAN-15:30 | 0.00 | 01-JAN-00:10 | 6737.90 | 14-JAN-15:30 | 5124.36 | 14-JAN-15:30 | 1613.54 | 14-JAN-15:30 | 1779.10 | 14-JAN-15:00 | 0.00 | 01-JAN-00:10 |
February | 0.469750E+10 | 0.127912E+10 | 270.33 | 0.385281E+10 | 0.844684E+09 | 0.00 | 0.58 | 24-FEB-16:00 | 0.00 | 01-FEB-00:10 | 11234.88 | 24-FEB-16:00 | 9072.93 | 24-FEB-15:50 | 3317.99 | 25-FEB-17:00 | 2995.06 | 24-FEB-16:00 | 0.00 | 01-FEB-00:10 |
March | 0.128295E+11 | 0.350730E+10 | 397.59 | 0.108132E+11 | 0.201634E+10 | 0.00 | 1.00 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 | 45689.70 | 11-MAR-07:02 | 37214.83 | 29-MAR-06:02 | 10520.67 | 11-MAR-07:02 | 10153.24 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 |
April | 0.218246E+11 | 0.620064E+10 | 416.11 | 0.194145E+11 | 0.241014E+10 | 0.00 | 1.00 | 01-APR-06:02 | 0.00 | 01-APR-00:10 | 45827.45 | 17-APR-05:01 | 43432.00 | 28-APR-05:01 | 10658.87 | 24-APR-06:02 | 10992.55 | 27-APR-05:01 | 0.00 | 01-APR-00:10 |
May | 0.326912E+11 | 0.933962E+10 | 443.31 | 0.270593E+11 | 0.563195E+10 | 0.00 | 1.00 | 01-MAY-05:02 | 0.00 | 01-MAY-00:10 | 48447.03 | 24-MAY-05:02 | 43533.99 | 06-MAY-05:01 | 20329.02 | 24-MAY-06:04 | 11259.80 | 31-MAY-05:01 | 0.00 | 01-MAY-00:10 |
June | 0.363812E+11 | 0.101538E+11 | 436.78 | 0.277611E+11 | 0.862012E+10 | 0.00 | 1.00 | 01-JUN-05:02 | 0.00 | 01-JUN-00:10 | 49789.33 | 26-JUN-05:02 | 42192.58 | 12-JUN-04:02 | 24711.38 | 26-JUN-05:02 | 11539.19 | 12-JUN-05:01 | 0.00 | 01-JUN-00:10 |
July | 0.402475E+11 | 0.103825E+11 | 444.65 | 0.270634E+11 | 0.131841E+11 | 0.00 | 1.00 | 01-JUL-05:01 | 0.00 | 01-JUL-00:10 | 50086.14 | 20-JUL-05:02 | 37569.06 | 07-JUL-05:01 | 25344.20 | 20-JUL-05:03 | 11660.56 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.396478E+11 | 0.989804E+10 | 448.80 | 0.257218E+11 | 0.139260E+11 | 0.00 | 1.00 | 01-AUG-05:01 | 0.00 | 01-AUG-00:10 | 49320.04 | 10-AUG-05:01 | 35491.29 | 09-AUG-05:01 | 21882.12 | 17-AUG-06:04 | 11119.03 | 13-AUG-08:15 | 0.00 | 01-AUG-00:10 |
September | 0.319947E+11 | 0.803144E+10 | 428.79 | 0.215089E+11 | 0.104858E+11 | 0.00 | 1.00 | 01-SEP-05:01 | 0.00 | 01-SEP-00:10 | 49408.84 | 03-SEP-07:02 | 37429.15 | 27-SEP-05:01 | 24783.00 | 10-SEP-08:04 | 10856.19 | 24-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.209770E+11 | 0.556193E+10 | 415.41 | 0.169018E+11 | 0.407521E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:10 | 47506.21 | 12-OCT-06:02 | 39905.35 | 02-OCT-05:01 | 18358.32 | 12-OCT-06:04 | 10394.97 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.102371E+11 | 0.276826E+10 | 363.15 | 0.859145E+10 | 0.164564E+10 | 0.00 | 0.92 | 10-NOV-07:03 | 0.00 | 01-NOV-00:10 | 30053.89 | 09-NOV-07:02 | 23041.28 | 11-NOV-09:02 | 8142.60 | 09-NOV-07:02 | 6489.96 | 09-NOV-07:02 | 0.00 | 01-NOV-00:10 |
December | 0.298900E+10 | 0.817075E+09 | 236.36 | 0.245498E+10 | 0.534019E+09 | 0.00 | 0.42 | 01-DEC-15:10 | 0.00 | 01-DEC-00:10 | 7474.19 | 01-DEC-15:10 | 6806.06 | 01-DEC-15:10 | 1660.13 | 16-DEC-16:00 | 2001.92 | 01-DEC-15:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.255883E+12 | 0.683160E+11 | 4452.18 | 0.192246E+12 | 0.636363E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.136538E+10 | 0.376347E+09 | 150.88 | 0.110312E+10 | 0.262256E+09 | 0.00 | 0.37 | 0.00 | 6737.90 | 5124.36 | 1613.54 | 1779.10 | 0.00 | |||||||
Maximum of Months | 0.402475E+11 | 0.103825E+11 | 448.80 | 0.277611E+11 | 0.139260E+11 | 0.00 | 1.00 | 0.00 | 50086.14 | 43533.99 | 25344.20 | 11660.56 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.742609E+10 | 0.222983E+10 | 161.57 | 0.602535E+10 | 0.140074E+10 | 0.00 | 0.41 | 14-JAN-15:00 | 0.00 | 01-JAN-00:10 | 32723.95 | 14-JAN-15:00 | 26510.31 | 12-JAN-15:10 | 8577.81 | 14-JAN-15:00 | 9394.76 | 14-JAN-15:00 | 0.00 | 01-JAN-00:10 |
February | 0.242587E+11 | 0.714794E+10 | 268.37 | 0.194743E+11 | 0.478433E+10 | 0.00 | 0.66 | 24-FEB-15:40 | 0.00 | 01-FEB-00:10 | 56353.94 | 24-FEB-15:40 | 45504.63 | 22-FEB-15:10 | 19010.14 | 25-FEB-17:00 | 16130.36 | 24-FEB-15:40 | 0.00 | 01-FEB-00:10 |
March | 0.646687E+11 | 0.189489E+11 | 392.60 | 0.526492E+11 | 0.120196E+11 | 0.00 | 1.00 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 | 197004.10 | 11-MAR-07:02 | 145454.73 | 13-MAR-06:02 | 54359.73 | 29-MAR-06:02 | 48130.29 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 |
April | 0.105631E+12 | 0.321654E+11 | 413.47 | 0.912189E+11 | 0.144118E+11 | 0.00 | 1.00 | 01-APR-06:02 | 0.00 | 01-APR-00:10 | 200918.47 | 26-APR-06:02 | 177171.99 | 09-APR-08:62 | 68534.57 | 24-APR-06:02 | 52466.83 | 16-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.155112E+12 | 0.473442E+11 | 443.33 | 0.120944E+12 | 0.341680E+11 | 0.00 | 1.00 | 01-MAY-05:02 | 0.00 | 01-MAY-00:10 | 208440.29 | 24-MAY-06:02 | 180581.65 | 01-MAY-05:02 | 94396.99 | 24-MAY-06:04 | 53851.20 | 04-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.174723E+12 | 0.514363E+11 | 435.15 | 0.120554E+12 | 0.541697E+11 | 0.00 | 1.00 | 01-JUN-05:02 | 0.00 | 01-JUN-00:10 | 214626.23 | 25-JUN-08:62 | 169084.51 | 12-JUN-05:01 | 113164.55 | 25-JUN-08:62 | 55005.88 | 12-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.191375E+12 | 0.517527E+11 | 443.12 | 0.109198E+12 | 0.821768E+11 | 0.00 | 1.00 | 01-JUL-05:01 | 0.00 | 01-JUL-00:10 | 214894.55 | 28-JUL-06:02 | 146910.66 | 05-JUL-05:01 | 114635.78 | 28-JUL-06:06 | 55503.39 | 02-JUL-08:15 | 0.00 | 01-JUL-00:10 |
August | 0.190164E+12 | 0.497367E+11 | 448.15 | 0.101705E+12 | 0.884598E+11 | 0.00 | 1.00 | 01-AUG-05:01 | 0.00 | 01-AUG-00:10 | 216676.89 | 20-AUG-08:62 | 132583.92 | 07-AUG-05:01 | 120755.71 | 20-AUG-08:62 | 52795.59 | 08-AUG-06:02 | 0.00 | 01-AUG-00:10 |
September | 0.153009E+12 | 0.404327E+11 | 427.44 | 0.870980E+11 | 0.659114E+11 | 0.00 | 1.00 | 01-SEP-05:01 | 0.00 | 01-SEP-00:10 | 216736.40 | 10-SEP-08:62 | 136845.47 | 26-SEP-05:01 | 122239.14 | 10-SEP-08:62 | 51727.10 | 24-SEP-08:04 | 0.00 | 01-SEP-00:10 |
October | 0.952721E+11 | 0.272643E+11 | 408.51 | 0.713226E+11 | 0.239495E+11 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 206850.44 | 12-OCT-06:02 | 153036.57 | 15-OCT-08:62 | 95980.34 | 12-OCT-06:02 | 49811.47 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.484043E+11 | 0.141598E+11 | 350.99 | 0.391660E+11 | 0.923837E+10 | 0.00 | 0.79 | 09-NOV-13:30 | 0.00 | 01-NOV-00:10 | 101740.86 | 11-NOV-09:02 | 70708.54 | 11-NOV-09:02 | 31032.32 | 11-NOV-09:02 | 24194.33 | 11-NOV-09:02 | 0.00 | 01-NOV-00:10 |
December | 0.139829E+11 | 0.416277E+10 | 226.00 | 0.112136E+11 | 0.276928E+10 | 0.00 | 0.48 | 01-DEC-15:10 | 0.00 | 01-DEC-00:10 | 37646.85 | 28-DEC-15:10 | 33542.99 | 02-DEC-14:30 | 8948.58 | 16-DEC-16:10 | 11087.79 | 28-DEC-15:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.122403E+13 | 0.346782E+12 | 4418.71 | 0.830568E+12 | 0.393459E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.742609E+10 | 0.222983E+10 | 161.57 | 0.602535E+10 | 0.140074E+10 | 0.00 | 0.41 | 0.00 | 32723.95 | 26510.31 | 8577.81 | 9394.76 | 0.00 | |||||||
Maximum of Months | 0.191375E+12 | 0.517527E+11 | 448.15 | 0.120944E+12 | 0.884598E+11 | 0.00 | 1.00 | 0.00 | 216736.40 | 180581.65 | 122239.14 | 55503.39 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.444213E+10 | 0.112439E+10 | 307.03 | 0.385872E+10 | 0.583410E+09 | 0.00 | 0.70 | 12-JAN-15:10 | 0.00 | 01-JAN-00:10 | 8741.53 | 12-JAN-15:10 | 7961.40 | 12-JAN-15:10 | 1511.93 | 13-JAN-13:50 | 2130.12 | 12-JAN-15:10 | 0.00 | 01-JAN-00:10 |
February | 0.674889E+10 | 0.169078E+10 | 327.47 | 0.579430E+10 | 0.954592E+09 | 0.00 | 0.85 | 22-FEB-14:20 | 0.00 | 01-FEB-00:10 | 11017.39 | 22-FEB-14:20 | 9960.21 | 22-FEB-14:20 | 2530.55 | 25-FEB-16:00 | 2729.02 | 22-FEB-14:30 | 0.00 | 01-FEB-00:10 |
March | 0.118873E+11 | 0.304021E+10 | 417.43 | 0.102391E+11 | 0.164817E+10 | 0.00 | 1.00 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 | 29218.24 | 11-MAR-07:02 | 23219.67 | 29-MAR-06:02 | 6806.61 | 11-MAR-07:02 | 6406.44 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 |
April | 0.160677E+11 | 0.441480E+10 | 422.66 | 0.143298E+11 | 0.173790E+10 | 0.00 | 1.00 | 01-APR-06:02 | 0.00 | 01-APR-00:10 | 29681.60 | 17-APR-05:01 | 27915.38 | 28-APR-05:01 | 8326.31 | 24-APR-06:02 | 6976.26 | 27-APR-05:01 | 0.00 | 01-APR-00:10 |
May | 0.218750E+11 | 0.613617E+10 | 447.95 | 0.179106E+11 | 0.396439E+10 | 0.00 | 1.00 | 01-MAY-05:02 | 0.00 | 01-MAY-00:10 | 31440.98 | 24-MAY-05:02 | 27206.46 | 06-MAY-05:01 | 13592.77 | 24-MAY-06:02 | 7216.74 | 04-MAY-04:02 | 0.00 | 01-MAY-00:10 |
June | 0.240680E+11 | 0.657844E+10 | 441.52 | 0.179566E+11 | 0.611145E+10 | 0.00 | 1.00 | 01-JUN-05:02 | 0.00 | 01-JUN-00:10 | 32394.86 | 26-JUN-05:02 | 26749.16 | 12-JUN-04:02 | 16503.66 | 26-JUN-05:02 | 7341.63 | 14-JUN-04:02 | 0.00 | 01-JUN-00:10 |
July | 0.266999E+11 | 0.673919E+10 | 449.28 | 0.173426E+11 | 0.935726E+10 | 0.00 | 1.00 | 01-JUL-05:01 | 0.00 | 01-JUL-00:10 | 32473.27 | 20-JUL-05:02 | 23739.19 | 07-JUL-04:02 | 16825.58 | 20-JUL-05:03 | 7400.35 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.267676E+11 | 0.654591E+10 | 452.94 | 0.167643E+11 | 0.100033E+11 | 0.00 | 1.00 | 01-AUG-05:01 | 0.00 | 01-AUG-00:10 | 31933.25 | 19-AUG-05:01 | 21485.68 | 15-AUG-05:01 | 15530.17 | 12-AUG-06:04 | 7048.62 | 08-AUG-05:01 | 0.00 | 01-AUG-00:10 |
September | 0.228489E+11 | 0.560511E+10 | 430.31 | 0.151662E+11 | 0.768270E+10 | 0.00 | 1.00 | 01-SEP-05:01 | 0.00 | 01-SEP-00:10 | 32172.00 | 03-SEP-07:02 | 24026.08 | 27-SEP-05:01 | 16942.62 | 10-SEP-08:62 | 6898.47 | 24-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.177213E+11 | 0.445007E+10 | 430.85 | 0.145255E+11 | 0.319583E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:10 | 30710.13 | 12-OCT-06:02 | 25854.23 | 02-OCT-05:01 | 12714.59 | 12-OCT-06:02 | 6587.16 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.120162E+11 | 0.294851E+10 | 391.78 | 0.104453E+11 | 0.157082E+10 | 0.00 | 1.00 | 09-NOV-07:02 | 0.00 | 01-NOV-00:10 | 29107.08 | 09-NOV-07:02 | 23693.13 | 12-NOV-09:02 | 7045.40 | 09-NOV-07:02 | 6174.28 | 09-NOV-07:02 | 0.00 | 01-NOV-00:10 |
December | 0.627727E+10 | 0.156741E+10 | 348.35 | 0.544680E+10 | 0.830472E+09 | 0.00 | 0.78 | 02-DEC-14:00 | 0.00 | 01-DEC-00:10 | 9750.52 | 02-DEC-14:00 | 9308.17 | 02-DEC-14:00 | 1488.93 | 16-DEC-14:20 | 2355.04 | 28-DEC-14:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.197420E+12 | 0.508410E+11 | 4867.55 | 0.149780E+12 | 0.476403E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.444213E+10 | 0.112439E+10 | 307.03 | 0.385872E+10 | 0.583410E+09 | 0.00 | 0.70 | 0.00 | 8741.53 | 7961.40 | 1488.93 | 2130.12 | 0.00 | |||||||
Maximum of Months | 0.267676E+11 | 0.673919E+10 | 452.94 | 0.179566E+11 | 0.100033E+11 | 0.00 | 1.00 | 0.00 | 32473.27 | 27915.38 | 16942.62 | 7400.35 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.199375E+10 | 0.516723E+09 | 210.10 | 0.169855E+10 | 0.295198E+09 | 0.00 | 0.62 | 12-JAN-15:10 | 0.00 | 01-JAN-00:10 | 6320.40 | 12-JAN-15:10 | 5603.66 | 12-JAN-15:10 | 1278.80 | 13-JAN-14:00 | 1577.88 | 12-JAN-15:10 | 0.00 | 01-JAN-00:10 |
February | 0.405275E+10 | 0.103765E+10 | 275.83 | 0.340303E+10 | 0.649714E+09 | 0.00 | 0.81 | 22-FEB-14:20 | 0.00 | 01-FEB-00:10 | 8717.19 | 22-FEB-14:20 | 7707.20 | 22-FEB-14:30 | 2137.60 | 25-FEB-15:40 | 2183.28 | 22-FEB-14:30 | 0.00 | 01-FEB-00:10 |
March | 0.858911E+10 | 0.223108E+10 | 389.12 | 0.721055E+10 | 0.137856E+10 | 0.00 | 1.00 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 | 24524.51 | 11-MAR-07:02 | 18551.47 | 29-MAR-06:02 | 6471.42 | 11-MAR-07:02 | 5367.37 | 11-MAR-07:02 | 0.00 | 01-MAR-00:10 |
April | 0.129274E+11 | 0.356744E+10 | 417.36 | 0.113359E+11 | 0.159149E+10 | 0.00 | 1.00 | 01-APR-06:02 | 0.00 | 01-APR-00:10 | 24803.07 | 24-APR-06:02 | 22755.87 | 28-APR-05:01 | 8018.23 | 24-APR-06:02 | 5829.67 | 27-APR-05:01 | 0.00 | 01-APR-00:10 |
May | 0.184496E+11 | 0.514643E+10 | 445.47 | 0.147417E+11 | 0.370791E+10 | 0.00 | 1.00 | 01-MAY-05:02 | 0.00 | 01-MAY-00:10 | 26265.43 | 24-MAY-05:02 | 22582.70 | 01-MAY-05:02 | 12457.93 | 24-MAY-06:04 | 5981.51 | 04-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.205504E+11 | 0.556360E+10 | 439.35 | 0.147768E+11 | 0.577365E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 27086.98 | 26-JUN-05:02 | 21437.91 | 12-JUN-04:02 | 14698.27 | 26-JUN-05:02 | 6113.17 | 12-JUN-04:02 | 0.00 | 01-JUN-00:10 |
July | 0.230627E+11 | 0.575017E+10 | 447.43 | 0.141665E+11 | 0.889613E+10 | 0.00 | 1.00 | 01-JUL-05:01 | 0.00 | 01-JUL-00:10 | 27133.08 | 20-JUL-05:02 | 18418.16 | 07-JUL-05:01 | 14926.66 | 20-JUL-05:03 | 6189.87 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.230153E+11 | 0.555573E+10 | 451.32 | 0.135040E+11 | 0.951124E+10 | 0.00 | 1.00 | 01-AUG-05:01 | 0.00 | 01-AUG-00:10 | 26911.64 | 10-AUG-05:01 | 17307.48 | 09-AUG-05:01 | 14222.18 | 12-AUG-06:02 | 5892.87 | 08-AUG-05:01 | 0.00 | 01-AUG-00:10 |
September | 0.192943E+11 | 0.469345E+10 | 429.54 | 0.120824E+11 | 0.721189E+10 | 0.00 | 1.00 | 01-SEP-05:01 | 0.00 | 01-SEP-00:10 | 27025.41 | 10-SEP-08:62 | 18665.55 | 27-SEP-05:01 | 15583.16 | 10-SEP-08:62 | 5771.75 | 24-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.143825E+11 | 0.362120E+10 | 423.81 | 0.114356E+11 | 0.294686E+10 | 0.00 | 1.00 | 01-OCT-07:02 | 0.00 | 01-OCT-00:10 | 25851.40 | 12-OCT-06:02 | 20497.75 | 02-OCT-05:01 | 12004.55 | 12-OCT-06:02 | 5521.83 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.891186E+10 | 0.221404E+10 | 372.92 | 0.755061E+10 | 0.136125E+10 | 0.00 | 1.00 | 11-NOV-09:02 | 0.00 | 01-NOV-00:10 | 24119.21 | 11-NOV-09:02 | 18881.75 | 12-NOV-09:02 | 6804.75 | 09-NOV-07:02 | 5123.96 | 11-NOV-09:02 | 0.00 | 01-NOV-00:10 |
December | 0.337413E+10 | 0.861194E+09 | 283.37 | 0.283845E+10 | 0.535674E+09 | 0.00 | 0.73 | 02-DEC-14:00 | 0.00 | 01-DEC-00:10 | 7487.32 | 02-DEC-14:00 | 7031.89 | 02-DEC-14:00 | 1299.05 | 16-DEC-14:10 | 1831.35 | 02-DEC-14:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.158604E+12 | 0.407587E+11 | 4585.63 | 0.114744E+12 | 0.438596E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.199375E+10 | 0.516723E+09 | 210.10 | 0.169855E+10 | 0.295198E+09 | 0.00 | 0.62 | 0.00 | 6320.40 | 5603.66 | 1278.80 | 1577.88 | 0.00 | |||||||
Maximum of Months | 0.230627E+11 | 0.575017E+10 | 451.32 | 0.147768E+11 | 0.951124E+10 | 0.00 | 1.00 | 0.00 | 27133.08 | 22755.87 | 15583.16 | 6189.87 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.02 | 42.55 | 37.47 | 92.55 | 56.68 | 13.00 | 0.00 | 744.00 |
February | 102.03 | 57.10 | 44.92 | 126.16 | 47.21 | 0.00 | 0.00 | 672.00 |
March | 135.00 | 80.16 | 54.84 | 179.01 | 33.40 | 0.00 | 0.00 | 744.00 |
April | 175.52 | 122.75 | 52.77 | 247.79 | 19.97 | 0.00 | 0.00 | 720.00 |
May | 185.22 | 127.65 | 57.58 | 269.07 | 10.00 | 0.00 | 0.00 | 744.00 |
June | 173.59 | 110.15 | 63.44 | 255.90 | 5.99 | 0.00 | 0.00 | 720.00 |
July | 121.69 | 43.38 | 78.31 | 183.37 | 3.57 | 0.00 | 0.00 | 744.00 |
August | 104.93 | 29.53 | 75.40 | 157.38 | 5.55 | 0.00 | 0.00 | 744.00 |
September | 108.96 | 46.46 | 62.49 | 154.79 | 11.99 | 0.00 | 0.00 | 720.00 |
October | 120.78 | 76.35 | 44.43 | 166.41 | 30.28 | 0.00 | 0.00 | 744.00 |
November | 101.42 | 66.79 | 34.63 | 130.28 | 46.64 | 0.00 | 0.00 | 720.00 |
December | 77.91 | 41.88 | 36.04 | 91.18 | 58.07 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 123.93 | 70.33 | 53.60 | 171.24 | 27.35 | 13.00 | 0.00 | 8760.00 |
Minimum of Months | 77.91 | 29.53 | 34.63 | 91.18 | 3.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 185.22 | 127.65 | 78.31 | 269.07 | 58.07 | 13.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 904.59 | 549.75 | 354.85 | 1211.81 | 691.34 | 0.00 | 0.00 | 744.00 |
February | 860.00 | 477.70 | 382.29 | 1215.79 | 563.72 | 0.00 | 0.00 | 672.00 |
March | 735.08 | 324.58 | 410.49 | 1129.06 | 357.73 | 0.00 | 0.00 | 744.00 |
April | 516.20 | 145.52 | 370.68 | 970.80 | 147.51 | 0.00 | 0.00 | 720.00 |
May | 371.16 | 27.27 | 343.90 | 949.41 | 40.07 | 0.00 | 0.00 | 744.00 |
June | 339.62 | 5.69 | 333.93 | 968.77 | 23.09 | 0.00 | 0.00 | 720.00 |
July | 354.31 | 4.82 | 349.49 | 903.91 | 11.84 | 0.00 | 0.00 | 744.00 |
August | 375.85 | 20.02 | 355.83 | 841.41 | 31.72 | 0.00 | 0.00 | 744.00 |
September | 503.84 | 130.71 | 373.14 | 954.04 | 89.48 | 0.00 | 0.00 | 720.00 |
October | 866.93 | 484.08 | 382.86 | 1479.52 | 311.32 | 0.00 | 0.00 | 744.00 |
November | 1083.19 | 716.07 | 367.12 | 1691.51 | 537.13 | 0.00 | 0.00 | 720.00 |
December | 966.72 | 605.87 | 360.84 | 1348.23 | 695.45 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 655.29 | 289.93 | 365.36 | 1137.97 | 290.48 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 339.62 | 4.82 | 333.93 | 841.41 | 11.84 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1083.19 | 716.07 | 410.49 | 1691.51 | 695.45 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 904.59 | 549.75 | 354.85 | 1219.52 | 661.35 | 0.00 | 0.00 | 744.00 |
February | 860.00 | 477.70 | 382.29 | 1219.33 | 541.31 | 0.00 | 0.00 | 672.00 |
March | 735.08 | 324.58 | 410.49 | 1127.56 | 340.15 | 0.00 | 0.00 | 744.00 |
April | 516.20 | 145.52 | 370.68 | 969.05 | 133.93 | 0.00 | 0.00 | 720.00 |
May | 371.16 | 27.27 | 343.90 | 952.00 | 31.99 | 0.00 | 0.00 | 744.00 |
June | 339.62 | 5.69 | 333.93 | 974.96 | 18.05 | 0.00 | 0.00 | 720.00 |
July | 354.31 | 4.82 | 349.49 | 909.62 | 7.86 | 0.00 | 0.00 | 744.00 |
August | 375.85 | 20.02 | 355.83 | 842.65 | 24.05 | 0.00 | 0.00 | 744.00 |
September | 503.84 | 130.71 | 373.14 | 952.11 | 76.00 | 0.00 | 0.00 | 720.00 |
October | 866.93 | 484.08 | 382.86 | 1475.89 | 297.16 | 0.00 | 0.00 | 744.00 |
November | 1083.19 | 716.07 | 367.12 | 1690.23 | 520.90 | 0.00 | 0.00 | 720.00 |
December | 966.72 | 605.87 | 360.84 | 1353.09 | 673.10 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 655.29 | 289.93 | 365.36 | 1139.79 | 275.97 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 339.62 | 4.82 | 333.93 | 842.65 | 7.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1083.19 | 716.07 | 410.49 | 1690.23 | 673.10 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 186.13 | 113.12 | 73.01 | 262.63 | 119.95 | 0.00 | 0.00 | 744.00 |
February | 176.96 | 98.29 | 78.66 | 252.63 | 104.18 | 0.00 | 0.00 | 672.00 |
March | 151.25 | 66.79 | 84.47 | 218.15 | 73.62 | 0.00 | 0.00 | 744.00 |
April | 106.22 | 29.94 | 76.27 | 156.93 | 37.22 | 0.00 | 0.00 | 720.00 |
May | 76.37 | 5.61 | 70.76 | 129.17 | 14.87 | 0.00 | 0.00 | 744.00 |
June | 69.88 | 1.17 | 68.71 | 131.34 | 9.09 | 0.00 | 0.00 | 720.00 |
July | 72.90 | 0.99 | 71.91 | 131.61 | 4.86 | 4.83 | 0.00 | 744.00 |
August | 77.34 | 4.12 | 73.22 | 129.63 | 11.21 | 0.50 | 0.00 | 744.00 |
September | 103.67 | 26.89 | 76.78 | 159.68 | 26.07 | 10.83 | 0.00 | 720.00 |
October | 178.38 | 99.61 | 78.78 | 276.18 | 73.03 | 0.00 | 0.00 | 744.00 |
November | 222.88 | 147.34 | 75.54 | 335.93 | 108.92 | 0.00 | 0.00 | 720.00 |
December | 198.92 | 124.67 | 74.25 | 286.45 | 123.81 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 134.83 | 59.66 | 75.18 | 205.58 | 58.68 | 16.17 | 0.00 | 8760.00 |
Minimum of Months | 69.88 | 0.99 | 68.71 | 129.17 | 4.86 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 222.88 | 147.34 | 84.47 | 335.93 | 123.81 | 10.83 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214320E+09 | 0.113961E+09 | 0.100359E+09 | 0.247882E+09 | 0.151808E+09 |
February | 0.246820E+09 | 0.138147E+09 | 0.108673E+09 | 0.305212E+09 | 0.114211E+09 |
March | 0.361595E+09 | 0.214707E+09 | 0.146888E+09 | 0.479449E+09 | 89450334.92 |
April | 0.454937E+09 | 0.318167E+09 | 0.136771E+09 | 0.642268E+09 | 51754803.02 |
May | 0.496103E+09 | 0.341893E+09 | 0.154210E+09 | 0.720680E+09 | 26796190.30 |
June | 0.449956E+09 | 0.285516E+09 | 0.164441E+09 | 0.663305E+09 | 15516824.51 |
July | 0.325929E+09 | 0.116191E+09 | 0.209738E+09 | 0.491130E+09 | 9553429.65 |
August | 0.281048E+09 | 79099543.10 | 0.201948E+09 | 0.421528E+09 | 14877630.91 |
September | 0.282413E+09 | 0.120436E+09 | 0.161977E+09 | 0.401219E+09 | 31080329.24 |
October | 0.323499E+09 | 0.204504E+09 | 0.118996E+09 | 0.445709E+09 | 81101376.51 |
November | 0.262887E+09 | 0.173114E+09 | 89772742.24 | 0.337684E+09 | 0.120886E+09 |
December | 0.208680E+09 | 0.112160E+09 | 96520417.23 | 0.244210E+09 | 0.155541E+09 |
Annual Sum or Average | 0.390819E+10 | 0.221789E+10 | 0.169029E+10 | 0.540028E+10 | 0.862578E+09 |
Minimum of Months | 0.208680E+09 | 79099543.10 | 89772742.24 | 0.244210E+09 | 9553429.65 |
Maximum of Months | 0.496103E+09 | 0.341893E+09 | 0.209738E+09 | 0.720680E+09 | 0.155541E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.242287E+10 | 0.147244E+10 | 0.950422E+09 | 0.324572E+10 | 0.185168E+10 |
February | 0.208051E+10 | 0.115566E+10 | 0.924844E+09 | 0.294125E+10 | 0.136376E+10 |
March | 0.196882E+10 | 0.869357E+09 | 0.109947E+10 | 0.302408E+10 | 0.958144E+09 |
April | 0.133799E+10 | 0.377179E+09 | 0.960814E+09 | 0.251631E+10 | 0.382338E+09 |
May | 0.994120E+09 | 73030265.73 | 0.921090E+09 | 0.254290E+10 | 0.107313E+09 |
June | 0.880289E+09 | 14749543.78 | 0.865540E+09 | 0.251105E+10 | 59840190.94 |
July | 0.948978E+09 | 12900131.21 | 0.936077E+09 | 0.242102E+10 | 31723438.30 |
August | 0.100667E+10 | 53611578.95 | 0.953056E+09 | 0.225364E+10 | 84967540.85 |
September | 0.130596E+10 | 0.338790E+09 | 0.967169E+09 | 0.247286E+10 | 0.231938E+09 |
October | 0.232199E+10 | 0.129655E+10 | 0.102544E+10 | 0.396274E+10 | 0.833836E+09 |
November | 0.280763E+10 | 0.185605E+10 | 0.951577E+09 | 0.438440E+10 | 0.139224E+10 |
December | 0.258925E+10 | 0.162277E+10 | 0.966486E+09 | 0.361109E+10 | 0.186269E+10 |
Annual Sum or Average | 0.206651E+11 | 0.914309E+10 | 0.115220E+11 | 0.358871E+11 | 0.916047E+10 |
Minimum of Months | 0.880289E+09 | 12900131.21 | 0.865540E+09 | 0.225364E+10 | 31723438.30 |
Maximum of Months | 0.280763E+10 | 0.185605E+10 | 0.109947E+10 | 0.438440E+10 | 0.186269E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.242287E+10 | 0.147244E+10 | 0.950422E+09 | 0.326637E+10 | 0.177136E+10 |
February | 0.208051E+10 | 0.115566E+10 | 0.924844E+09 | 0.294979E+10 | 0.130954E+10 |
March | 0.196882E+10 | 0.869357E+09 | 0.109947E+10 | 0.302006E+10 | 0.911056E+09 |
April | 0.133799E+10 | 0.377179E+09 | 0.960814E+09 | 0.251178E+10 | 0.347146E+09 |
May | 0.994120E+09 | 73030265.73 | 0.921090E+09 | 0.254983E+10 | 85688447.73 |
June | 0.880289E+09 | 14749543.78 | 0.865540E+09 | 0.252709E+10 | 46783149.16 |
July | 0.948978E+09 | 12900131.21 | 0.936077E+09 | 0.243633E+10 | 21049544.07 |
August | 0.100667E+10 | 53611578.95 | 0.953056E+09 | 0.225695E+10 | 64422476.50 |
September | 0.130596E+10 | 0.338790E+09 | 0.967169E+09 | 0.246788E+10 | 0.196989E+09 |
October | 0.232199E+10 | 0.129655E+10 | 0.102544E+10 | 0.395303E+10 | 0.795923E+09 |
November | 0.280763E+10 | 0.185605E+10 | 0.951577E+09 | 0.438108E+10 | 0.135017E+10 |
December | 0.258925E+10 | 0.162277E+10 | 0.966486E+09 | 0.362412E+10 | 0.180284E+10 |
Annual Sum or Average | 0.206651E+11 | 0.914309E+10 | 0.115220E+11 | 0.359443E+11 | 0.870297E+10 |
Minimum of Months | 0.880289E+09 | 12900131.21 | 0.865540E+09 | 0.225695E+10 | 21049544.07 |
Maximum of Months | 0.280763E+10 | 0.185605E+10 | 0.109947E+10 | 0.438108E+10 | 0.180284E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.498540E+09 | 0.302977E+09 | 0.195563E+09 | 0.703435E+09 | 0.321281E+09 |
February | 0.428095E+09 | 0.237795E+09 | 0.190300E+09 | 0.611173E+09 | 0.252029E+09 |
March | 0.405114E+09 | 0.178883E+09 | 0.226232E+09 | 0.584293E+09 | 0.197185E+09 |
April | 0.275312E+09 | 77610020.26 | 0.197702E+09 | 0.406769E+09 | 96476849.83 |
May | 0.204555E+09 | 15027040.58 | 0.189528E+09 | 0.345977E+09 | 39825500.65 |
June | 0.181132E+09 | 3034933.40 | 0.178097E+09 | 0.340433E+09 | 23551045.48 |
July | 0.195266E+09 | 2654389.84 | 0.192612E+09 | 0.352504E+09 | 13018257.53 |
August | 0.207136E+09 | 11031363.02 | 0.196105E+09 | 0.347192E+09 | 30021686.94 |
September | 0.268720E+09 | 69711043.12 | 0.199009E+09 | 0.413895E+09 | 67579908.12 |
October | 0.477784E+09 | 0.266784E+09 | 0.210999E+09 | 0.739714E+09 | 0.195615E+09 |
November | 0.577710E+09 | 0.381909E+09 | 0.195801E+09 | 0.870724E+09 | 0.282323E+09 |
December | 0.532776E+09 | 0.333908E+09 | 0.198869E+09 | 0.767217E+09 | 0.331601E+09 |
Annual Sum or Average | 0.425214E+10 | 0.188132E+10 | 0.237082E+10 | 0.648333E+10 | 0.185051E+10 |
Minimum of Months | 0.181132E+09 | 2654389.84 | 0.178097E+09 | 0.340433E+09 | 13018257.53 |
Maximum of Months | 0.577710E+09 | 0.381909E+09 | 0.226232E+09 | 0.870724E+09 | 0.331601E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1480.78 | 906.86 | 1280.29 | 680.77 | 599.52 | 0.00 | 0.00 |
February | 2018.60 | 755.36 | 1632.41 | 913.67 | 718.74 | 0.00 | 0.00 |
March | 2864.09 | 534.35 | 2160.06 | 1282.60 | 877.47 | 0.00 | 0.00 |
April | 3964.61 | 319.47 | 2808.25 | 1963.99 | 844.26 | 0.00 | 0.00 |
May | 4305.13 | 160.07 | 2963.58 | 2042.37 | 921.21 | 0.00 | 0.00 |
June | 4094.48 | 95.78 | 2777.51 | 1762.44 | 1015.07 | 0.00 | 0.00 |
July | 2933.87 | 57.07 | 1947.01 | 694.09 | 1252.92 | 0.00 | 0.00 |
August | 2518.09 | 88.87 | 1678.90 | 472.52 | 1206.38 | 0.00 | 0.00 |
September | 2476.66 | 191.85 | 1743.29 | 743.43 | 999.86 | 0.00 | 0.00 |
October | 2662.54 | 484.48 | 1932.49 | 1221.65 | 710.85 | 0.00 | 0.00 |
November | 2084.47 | 746.21 | 1622.76 | 1068.61 | 554.15 | 0.00 | 0.00 |
December | 1458.84 | 929.16 | 1246.60 | 670.01 | 576.59 | 0.00 | 0.00 |
Annual Sum or Average | 2739.87 | 437.63 | 1982.85 | 1125.26 | 857.58 | 0.00 | 0.00 |
Minimum of Months | 1458.84 | 57.07 | 1246.60 | 472.52 | 554.15 | 0.00 | 0.00 |
Maximum of Months | 4305.13 | 929.16 | 2963.58 | 2042.37 | 1252.92 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1211.81 | 691.34 | 904.59 | 549.75 | 354.85 | 0.00 | 0.00 |
February | 1215.79 | 563.72 | 860.00 | 477.70 | 382.29 | 0.00 | 0.00 |
March | 1129.06 | 357.73 | 735.08 | 324.58 | 410.49 | 0.00 | 0.00 |
April | 970.80 | 147.51 | 516.20 | 145.52 | 370.68 | 0.00 | 0.00 |
May | 949.41 | 40.07 | 371.16 | 27.27 | 343.90 | 0.00 | 0.00 |
June | 968.77 | 23.09 | 339.62 | 5.69 | 333.93 | 0.00 | 0.00 |
July | 903.91 | 11.84 | 354.31 | 4.82 | 349.49 | 0.00 | 0.00 |
August | 841.41 | 31.72 | 375.85 | 20.02 | 355.83 | 0.00 | 0.00 |
September | 954.04 | 89.48 | 503.84 | 130.71 | 373.14 | 0.00 | 0.00 |
October | 1479.52 | 311.32 | 866.93 | 484.08 | 382.86 | 0.00 | 0.00 |
November | 1691.51 | 537.13 | 1083.19 | 716.07 | 367.12 | 0.00 | 0.00 |
December | 1348.23 | 695.45 | 966.72 | 605.87 | 360.84 | 0.00 | 0.00 |
Annual Sum or Average | 1137.97 | 290.48 | 655.29 | 289.93 | 365.36 | 0.00 | 0.00 |
Minimum of Months | 841.41 | 11.84 | 339.62 | 4.82 | 333.93 | 0.00 | 0.00 |
Maximum of Months | 1691.51 | 695.45 | 1083.19 | 716.07 | 410.49 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1219.52 | 661.35 | 904.59 | 549.75 | 354.85 | 0.00 | 0.00 |
February | 1219.33 | 541.31 | 860.00 | 477.70 | 382.29 | 0.00 | 0.00 |
March | 1127.56 | 340.15 | 735.08 | 324.58 | 410.49 | 0.00 | 0.00 |
April | 969.05 | 133.93 | 516.20 | 145.52 | 370.68 | 0.00 | 0.00 |
May | 952.00 | 31.99 | 371.16 | 27.27 | 343.90 | 0.00 | 0.00 |
June | 974.96 | 18.05 | 339.62 | 5.69 | 333.93 | 0.00 | 0.00 |
July | 909.62 | 7.86 | 354.31 | 4.82 | 349.49 | 0.00 | 0.00 |
August | 842.65 | 24.05 | 375.85 | 20.02 | 355.83 | 0.00 | 0.00 |
September | 952.11 | 76.00 | 503.84 | 130.71 | 373.14 | 0.00 | 0.00 |
October | 1475.89 | 297.16 | 866.93 | 484.08 | 382.86 | 0.00 | 0.00 |
November | 1690.23 | 520.90 | 1083.19 | 716.07 | 367.12 | 0.00 | 0.00 |
December | 1353.09 | 673.10 | 966.72 | 605.87 | 360.84 | 0.00 | 0.00 |
Annual Sum or Average | 1139.79 | 275.97 | 655.29 | 289.93 | 365.36 | 0.00 | 0.00 |
Minimum of Months | 842.65 | 7.86 | 339.62 | 4.82 | 333.93 | 0.00 | 0.00 |
Maximum of Months | 1690.23 | 673.10 | 1083.19 | 716.07 | 410.49 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 262.63 | 119.95 | 186.13 | 113.12 | 73.01 | 0.00 | 0.00 |
February | 252.63 | 104.18 | 176.96 | 98.29 | 78.66 | 0.00 | 0.00 |
March | 218.15 | 73.62 | 151.25 | 66.79 | 84.47 | 0.00 | 0.00 |
April | 156.93 | 37.22 | 106.22 | 29.94 | 76.27 | 0.00 | 0.00 |
May | 129.17 | 14.87 | 76.37 | 5.61 | 70.76 | 0.00 | 0.00 |
June | 131.34 | 9.09 | 69.88 | 1.17 | 68.71 | 0.00 | 0.00 |
July | 131.61 | 4.86 | 72.90 | 0.99 | 71.91 | 0.00 | 0.00 |
August | 129.63 | 11.21 | 77.34 | 4.12 | 73.22 | 0.00 | 0.00 |
September | 159.68 | 26.07 | 103.67 | 26.89 | 76.78 | 0.00 | 0.00 |
October | 276.18 | 73.03 | 178.38 | 99.61 | 78.78 | 0.00 | 0.00 |
November | 335.93 | 108.92 | 222.88 | 147.34 | 75.54 | 0.00 | 0.00 |
December | 286.45 | 123.81 | 198.92 | 124.67 | 74.25 | 0.00 | 0.00 |
Annual Sum or Average | 205.58 | 58.68 | 134.83 | 59.66 | 75.18 | 0.00 | 0.00 |
Minimum of Months | 129.17 | 4.86 | 69.88 | 0.99 | 68.71 | 0.00 | 0.00 |
Maximum of Months | 335.93 | 123.81 | 222.88 | 147.34 | 84.47 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.396611E+10 | 0.242893E+10 | 0.342912E+10 | 0.182338E+10 | 0.160574E+10 | 0.00 | 0.00 |
February | 0.488340E+10 | 0.182738E+10 | 0.394912E+10 | 0.221035E+10 | 0.173877E+10 | 0.00 | 0.00 |
March | 0.767119E+10 | 0.143121E+10 | 0.578551E+10 | 0.343531E+10 | 0.235021E+10 | 0.00 | 0.00 |
April | 0.102763E+11 | 0.828077E+09 | 0.727900E+10 | 0.509067E+10 | 0.218833E+10 | 0.00 | 0.00 |
May | 0.115309E+11 | 0.428739E+09 | 0.793764E+10 | 0.547029E+10 | 0.246736E+10 | 0.00 | 0.00 |
June | 0.106129E+11 | 0.248269E+09 | 0.719930E+10 | 0.456825E+10 | 0.263105E+10 | 0.00 | 0.00 |
July | 0.785808E+10 | 0.152855E+09 | 0.521487E+10 | 0.185906E+10 | 0.335581E+10 | 0.00 | 0.00 |
August | 0.674444E+10 | 0.238042E+09 | 0.449676E+10 | 0.126559E+10 | 0.323117E+10 | 0.00 | 0.00 |
September | 0.641950E+10 | 0.497285E+09 | 0.451861E+10 | 0.192697E+10 | 0.259163E+10 | 0.00 | 0.00 |
October | 0.713135E+10 | 0.129762E+10 | 0.517598E+10 | 0.327206E+10 | 0.190393E+10 | 0.00 | 0.00 |
November | 0.540295E+10 | 0.193417E+10 | 0.420620E+10 | 0.276983E+10 | 0.143636E+10 | 0.00 | 0.00 |
December | 0.390736E+10 | 0.248866E+10 | 0.333889E+10 | 0.179456E+10 | 0.154433E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.864044E+11 | 0.138012E+11 | 0.625310E+11 | 0.354863E+11 | 0.270447E+11 | 0.00 | 0.00 |
Minimum of Months | 0.390736E+10 | 0.152855E+09 | 0.333889E+10 | 0.126559E+10 | 0.143636E+10 | 0.00 | 0.00 |
Maximum of Months | 0.115309E+11 | 0.248866E+10 | 0.793764E+10 | 0.547029E+10 | 0.335581E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.324572E+10 | 0.185168E+10 | 0.242287E+10 | 0.147244E+10 | 0.950422E+09 | 0.00 | 0.00 |
February | 0.294125E+10 | 0.136376E+10 | 0.208051E+10 | 0.115566E+10 | 0.924844E+09 | 0.00 | 0.00 |
March | 0.302408E+10 | 0.958144E+09 | 0.196882E+10 | 0.869357E+09 | 0.109947E+10 | 0.00 | 0.00 |
April | 0.251631E+10 | 0.382338E+09 | 0.133799E+10 | 0.377179E+09 | 0.960814E+09 | 0.00 | 0.00 |
May | 0.254290E+10 | 0.107313E+09 | 0.994120E+09 | 73030265.73 | 0.921090E+09 | 0.00 | 0.00 |
June | 0.251105E+10 | 59840190.94 | 0.880289E+09 | 14749543.78 | 0.865540E+09 | 0.00 | 0.00 |
July | 0.242102E+10 | 31723438.30 | 0.948978E+09 | 12900131.21 | 0.936077E+09 | 0.00 | 0.00 |
August | 0.225364E+10 | 84967540.85 | 0.100667E+10 | 53611578.95 | 0.953056E+09 | 0.00 | 0.00 |
September | 0.247286E+10 | 0.231938E+09 | 0.130596E+10 | 0.338790E+09 | 0.967169E+09 | 0.00 | 0.00 |
October | 0.396274E+10 | 0.833836E+09 | 0.232199E+10 | 0.129655E+10 | 0.102544E+10 | 0.00 | 0.00 |
November | 0.438440E+10 | 0.139224E+10 | 0.280763E+10 | 0.185605E+10 | 0.951577E+09 | 0.00 | 0.00 |
December | 0.361109E+10 | 0.186269E+10 | 0.258925E+10 | 0.162277E+10 | 0.966486E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.358871E+11 | 0.916047E+10 | 0.206651E+11 | 0.914309E+10 | 0.115220E+11 | 0.00 | 0.00 |
Minimum of Months | 0.225364E+10 | 31723438.30 | 0.880289E+09 | 12900131.21 | 0.865540E+09 | 0.00 | 0.00 |
Maximum of Months | 0.438440E+10 | 0.186269E+10 | 0.280763E+10 | 0.185605E+10 | 0.109947E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.326637E+10 | 0.177136E+10 | 0.242287E+10 | 0.147244E+10 | 0.950422E+09 | 0.00 | 0.00 |
February | 0.294979E+10 | 0.130954E+10 | 0.208051E+10 | 0.115566E+10 | 0.924844E+09 | 0.00 | 0.00 |
March | 0.302006E+10 | 0.911056E+09 | 0.196882E+10 | 0.869357E+09 | 0.109947E+10 | 0.00 | 0.00 |
April | 0.251178E+10 | 0.347146E+09 | 0.133799E+10 | 0.377179E+09 | 0.960814E+09 | 0.00 | 0.00 |
May | 0.254983E+10 | 85688447.73 | 0.994120E+09 | 73030265.73 | 0.921090E+09 | 0.00 | 0.00 |
June | 0.252709E+10 | 46783149.16 | 0.880289E+09 | 14749543.78 | 0.865540E+09 | 0.00 | 0.00 |
July | 0.243633E+10 | 21049544.07 | 0.948978E+09 | 12900131.21 | 0.936077E+09 | 0.00 | 0.00 |
August | 0.225695E+10 | 64422476.50 | 0.100667E+10 | 53611578.95 | 0.953056E+09 | 0.00 | 0.00 |
September | 0.246788E+10 | 0.196989E+09 | 0.130596E+10 | 0.338790E+09 | 0.967169E+09 | 0.00 | 0.00 |
October | 0.395303E+10 | 0.795923E+09 | 0.232199E+10 | 0.129655E+10 | 0.102544E+10 | 0.00 | 0.00 |
November | 0.438108E+10 | 0.135017E+10 | 0.280763E+10 | 0.185605E+10 | 0.951577E+09 | 0.00 | 0.00 |
December | 0.362412E+10 | 0.180284E+10 | 0.258925E+10 | 0.162277E+10 | 0.966486E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.359443E+11 | 0.870297E+10 | 0.206651E+11 | 0.914309E+10 | 0.115220E+11 | 0.00 | 0.00 |
Minimum of Months | 0.225695E+10 | 21049544.07 | 0.880289E+09 | 12900131.21 | 0.865540E+09 | 0.00 | 0.00 |
Maximum of Months | 0.438108E+10 | 0.180284E+10 | 0.280763E+10 | 0.185605E+10 | 0.109947E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.703435E+09 | 0.321281E+09 | 0.498540E+09 | 0.302977E+09 | 0.195563E+09 | 0.00 | 0.00 |
February | 0.611173E+09 | 0.252029E+09 | 0.428095E+09 | 0.237795E+09 | 0.190300E+09 | 0.00 | 0.00 |
March | 0.584293E+09 | 0.197185E+09 | 0.405114E+09 | 0.178883E+09 | 0.226232E+09 | 0.00 | 0.00 |
April | 0.406769E+09 | 96476849.83 | 0.275312E+09 | 77610020.26 | 0.197702E+09 | 0.00 | 0.00 |
May | 0.345977E+09 | 39825500.65 | 0.204555E+09 | 15027040.58 | 0.189528E+09 | 0.00 | 0.00 |
June | 0.340433E+09 | 23551045.48 | 0.181132E+09 | 3034933.40 | 0.178097E+09 | 0.00 | 0.00 |
July | 0.352504E+09 | 13018257.53 | 0.195266E+09 | 2654389.84 | 0.192612E+09 | 0.00 | 0.00 |
August | 0.347192E+09 | 30021686.94 | 0.207136E+09 | 11031363.02 | 0.196105E+09 | 0.00 | 0.00 |
September | 0.413895E+09 | 67579908.12 | 0.268720E+09 | 69711043.12 | 0.199009E+09 | 0.00 | 0.00 |
October | 0.739714E+09 | 0.195615E+09 | 0.477784E+09 | 0.266784E+09 | 0.210999E+09 | 0.00 | 0.00 |
November | 0.870724E+09 | 0.282323E+09 | 0.577710E+09 | 0.381909E+09 | 0.195801E+09 | 0.00 | 0.00 |
December | 0.767217E+09 | 0.331601E+09 | 0.532776E+09 | 0.333908E+09 | 0.198869E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.648333E+10 | 0.185051E+10 | 0.425214E+10 | 0.188132E+10 | 0.237082E+10 | 0.00 | 0.00 |
Minimum of Months | 0.340433E+09 | 13018257.53 | 0.181132E+09 | 2654389.84 | 0.178097E+09 | 0.00 | 0.00 |
Maximum of Months | 0.870724E+09 | 0.331601E+09 | 0.577710E+09 | 0.381909E+09 | 0.226232E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 13.39 | 10.37 | 7.87 | 1.20 | 0.37 | 63.33 | 149.51 | 0.00 |
February | 16.97 | 12.77 | 9.69 | 1.81 | 4.63 | 75.94 | 163.32 | 0.01 |
March | 22.37 | 15.59 | 11.23 | 1.86 | 10.07 | 92.70 | 193.23 | 0.00 |
April | 29.13 | 18.31 | 11.93 | 1.64 | 16.17 | 89.20 | 259.84 | 0.01 |
May | 32.98 | 21.95 | 16.72 | 2.17 | 21.14 | 97.31 | 248.85 | 0.02 |
June | 33.59 | 24.37 | 20.62 | 1.55 | 23.45 | 107.22 | 203.36 | 0.06 |
July | 31.67 | 26.28 | 24.51 | 2.27 | 24.88 | 132.35 | 83.14 | 0.02 |
August | 30.03 | 26.31 | 25.11 | 1.75 | 23.81 | 127.44 | 60.46 | 0.00 |
September | 28.75 | 24.69 | 23.21 | 1.33 | 20.22 | 105.62 | 105.60 | 0.08 |
October | 25.09 | 18.73 | 15.36 | 0.77 | 12.83 | 75.09 | 190.08 | 0.00 |
November | 19.63 | 14.45 | 10.99 | 0.66 | 5.78 | 58.54 | 201.10 | 0.00 |
December | 14.52 | 10.87 | 7.89 | 0.97 | 0.94 | 60.91 | 153.60 | 0.01 |
Annual Sum or Average | 24.88 | 18.75 | 15.46 | 1.50 | 13.74 | 90.59 | 167.44 | 0.02 |
Minimum of Months | 13.39 | 10.37 | 7.87 | 0.66 | 0.37 | 58.54 | 60.46 | 0.00 |
Maximum of Months | 33.59 | 26.31 | 25.11 | 2.27 | 24.88 | 132.35 | 259.84 | 0.08 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 23.60 | 12-JAN-14:00 | 14.18 | 7.40 | 3.80 | 8.15 | 163.00 | 476.00 |
February | 27.10 | 22-FEB-14:00 | 16.17 | 9.10 | 1.50 | 15.39 | 225.00 | 451.00 |
March | 35.60 | 28-MAR-14:00 | 18.47 | 7.70 | 0.00 | 19.52 | 182.00 | 699.00 |
April | 40.30 | 15-APR-14:00 | 20.63 | 10.00 | 6.70 | 28.43 | 201.00 | 649.50 |
May | 44.50 | 03-MAY-14:00 | 20.60 | 5.30 | 2.80 | 28.91 | 150.00 | 809.00 |
June | 44.60 | 07-JUN-15:00 | 21.49 | 9.10 | 3.10 | 28.43 | 167.00 | 640.50 |
July | 40.40 | 02-JUL-15:00 | 26.34 | 21.60 | 2.10 | 29.87 | 200.00 | 545.50 |
August | 37.30 | 07-AUG-14:00 | 26.56 | 22.90 | 3.00 | 29.87 | 311.00 | 370.00 |
September | 37.50 | 17-SEP-19:00 | 27.67 | 24.60 | 0.20 | 28.59 | 0.00 | 0.00 |
October | 36.40 | 02-OCT-14:20 | 21.02 | 13.00 | 1.80 | 21.61 | 187.33 | 678.83 |
November | 30.30 | 04-NOV-13:00 | 17.14 | 8.90 | 1.10 | 14.84 | 155.00 | 710.00 |
December | 24.60 | 28-DEC-13:00 | 15.28 | 8.90 | 2.80 | 10.88 | 181.50 | 535.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 23.60 | 14.18 | 5.30 | 0.00 | 8.15 | 0.00 | 0.00 | |
Maximum of Months | 44.60 | 27.67 | 24.60 | 6.70 | 29.87 | 311.00 | 809.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 4.80 | 05-JAN-06:00 | 4.73 | 4.60 | 0.00 | -10.2 | 0.00 | 0.00 |
February | 6.90 | 02-FEB-05:00 | 6.67 | 6.50 | 0.00 | -7.8 | 0.00 | 0.00 |
March | 13.30 | 01-MAR-03:00 | 10.55 | 8.30 | 0.80 | -1.4 | 0.00 | 0.00 |
April | 17.40 | 11-APR-04:00 | 13.57 | 10.90 | 0.00 | 3.06 | 0.00 | 0.00 |
May | 22.70 | 13-MAY-04:00 | 20.32 | 19.30 | 2.10 | 20.40 | 0.00 | 0.00 |
June | 23.30 | 18-JUN-04:00 | 21.80 | 21.20 | 2.70 | 17.75 | 0.00 | 0.00 |
July | 23.20 | 19-JUL-02:00 | 23.20 | 23.20 | 2.30 | 15.39 | 0.00 | 0.00 |
August | 23.40 | 15-AUG-23:00 | 22.91 | 22.80 | 2.40 | 21.78 | 0.00 | 0.00 |
September | 23.00 | 27-SEP-04:00 | 20.73 | 19.70 | 0.00 | 10.30 | 0.00 | 0.00 |
October | 15.50 | 31-OCT-04:00 | 14.07 | 13.20 | 0.00 | 1.80 | 0.00 | 0.00 |
November | 9.50 | 27-NOV-05:00 | 8.75 | 8.10 | 0.00 | -5.0 | 0.00 | 0.00 |
December | 5.00 | 21-DEC-04:00 | 4.08 | 3.00 | 0.00 | -10.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 4.80 | 4.08 | 3.00 | 0.00 | -10.5 | 0.00 | 0.00 | |
Maximum of Months | 23.40 | 23.20 | 23.20 | 2.70 | 21.78 | 0.00 | 0.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 15.61 | 17-JAN-14:00 | 18.20 | 14.10 | 1.00 | 11.07 | 198.00 | 56.50 |
February | 18.14 | 25-FEB-16:00 | 21.20 | 16.60 | 5.90 | 10.88 | 107.50 | 156.50 |
March | 21.36 | 10-MAR-18:49 | 29.25 | 17.73 | 2.10 | 21.44 | 0.00 | 0.00 |
April | 23.40 | 18-APR-13:00 | 37.10 | 17.80 | 5.70 | 23.49 | 233.50 | 671.50 |
May | 27.40 | 22-MAY-22:00 | 29.40 | 26.80 | 0.00 | 20.40 | 0.00 | 0.00 |
June | 28.92 | 28-JUN-12:00 | 34.40 | 27.50 | 1.00 | 25.49 | 332.50 | 501.50 |
July | 29.17 | 01-JUL-16:00 | 37.20 | 26.80 | 2.30 | 25.66 | 196.00 | 196.00 |
August | 29.16 | 27-AUG-15:00 | 35.10 | 27.40 | 1.30 | 29.55 | 256.00 | 129.00 |
September | 28.10 | 14-SEP-16:00 | 33.70 | 26.40 | 1.40 | 26.48 | 122.50 | 108.50 |
October | 23.05 | 06-OCT-10:00 | 28.60 | 20.80 | 1.30 | 20.22 | 327.00 | 348.50 |
November | 18.91 | 08-NOV-17:10 | 27.55 | 14.47 | 0.17 | 16.67 | 28.00 | 65.33 |
December | 15.64 | 29-DEC-19:00 | 16.80 | 14.90 | 4.80 | 13.54 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.61 | 16.80 | 14.10 | 0.00 | 10.88 | 0.00 | 0.00 | |
Maximum of Months | 29.17 | 37.20 | 27.50 | 5.90 | 29.55 | 332.50 | 671.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.10 | 17-JAN-13:00 | 17.80 | 15.47 | 0.90 | 9.72 | 260.50 | 81.50 |
February | 16.60 | 25-FEB-16:00 | 21.20 | 18.14 | 5.90 | 10.88 | 107.50 | 156.50 |
March | 18.30 | 10-MAR-19:00 | 27.70 | 21.24 | 2.10 | 21.44 | 0.00 | 0.00 |
April | 19.30 | 26-APR-23:10 | 28.53 | 22.03 | 0.00 | 15.60 | 0.00 | 0.00 |
May | 26.80 | 22-MAY-22:00 | 29.40 | 27.40 | 0.00 | 20.40 | 0.00 | 0.00 |
June | 27.50 | 28-JUN-12:00 | 34.40 | 28.92 | 1.00 | 25.49 | 332.50 | 501.50 |
July | 27.30 | 18-JUL-06:19 | 29.10 | 27.69 | 1.17 | 26.48 | 20.00 | 0.00 |
August | 28.80 | 12-AUG-07:00 | 29.10 | 28.83 | 2.90 | 26.81 | 113.00 | 6.50 |
September | 26.50 | 12-SEP-14:00 | 30.50 | 27.38 | 0.90 | 25.99 | 260.00 | 20.00 |
October | 21.10 | 06-OCT-08:00 | 25.50 | 22.40 | 0.30 | 17.21 | 239.00 | 159.00 |
November | 16.30 | 08-NOV-21:19 | 20.10 | 17.58 | 0.00 | 10.95 | 0.00 | 0.00 |
December | 14.90 | 29-DEC-20:10 | 16.72 | 15.59 | 4.73 | 13.13 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 14.10 | 16.72 | 15.47 | 0.00 | 9.72 | 0.00 | 0.00 | |
Maximum of Months | 28.80 | 34.40 | 28.92 | 5.90 | 26.81 | 332.50 | 501.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 20.92 | 27.26 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 21.74 | 33.91 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 24.21 | 44.04 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 27.79 | 55.91 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 31.48 | 58.43 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 34.27 | 54.82 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 35.42 | 39.75 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 34.60 | 34.68 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 32.04 | 35.55 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 28.44 | 39.44 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 24.77 | 33.85 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 22.02 | 26.79 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 28.18 | 40.37 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 20.92 | 26.79 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 35.42 | 58.43 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.217664E+10 | -.180388E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -372767670.4 | 58.99 | 0.00 | 0.00 |
February | 0.193613E+10 | -.160754E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -328584726.2 | 58.99 | 0.00 | 0.00 |
March | 0.205776E+10 | -.170249E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -355268396.2 | 58.99 | 0.00 | 0.00 |
April | 0.178983E+10 | -.145245E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -337386810.5 | 58.99 | 0.00 | 0.00 |
May | 0.167138E+10 | -.132685E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -344527887.0 | 58.99 | 0.00 | 0.00 |
June | 0.150129E+10 | -.116832E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -332964932.6 | 58.99 | 0.00 | 0.00 |
July | 0.146086E+10 | -.111747E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -343388700.5 | 58.99 | 0.00 | 0.00 |
August | 0.153871E+10 | -.119407E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -344639471.6 | 58.99 | 0.00 | 0.00 |
September | 0.159125E+10 | -.125598E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -335262377.4 | 58.99 | 0.00 | 0.00 |
October | 0.179846E+10 | -.144870E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -349756713.4 | 58.99 | 0.00 | 0.00 |
November | 0.190721E+10 | -.156207E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -345143559.7 | 58.99 | 0.00 | 0.00 |
December | 0.211992E+10 | -.175319E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -366735153.2 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.215494E+11 | -.173930E+11 | 8760.00 | -.415643E+10 | 58.99 | |||||
Minimum of Months | 0.146086E+10 | -.180388E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -372767670.4 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.217664E+10 | -.111747E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -328584726.2 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 319.33 | 0.80 | 0.50 | 14-JAN-11:39 | 323.38 | 8.09 | 0.00 | 30.00 | 266.49 | 6.65 | 0.00 | 4.67 |
February | 303.83 | 0.76 | 0.50 | 01-FEB-10:00 | 385.45 | 8.99 | 0.00 | 78.83 | 319.10 | 7.43 | 0.00 | 44.33 |
March | 364.50 | 0.71 | 0.50 | 01-MAR-10:00 | 2499.35 | 10.09 | 0.00 | 174.00 | 2685.86 | 8.50 | 0.00 | 103.17 |
April | 379.83 | 0.73 | 0.50 | 01-APR-10:20 | 421.38 | 10.32 | 0.00 | 128.67 | 350.10 | 8.69 | 0.00 | 72.50 |
May | 406.00 | 0.73 | 0.50 | 04-MAY-11:00 | 423.67 | 11.57 | 0.00 | 117.33 | 352.46 | 9.88 | 0.00 | 65.00 |
June | 386.67 | 0.71 | 0.50 | 01-JUN-09:09 | 454.45 | 12.32 | 0.00 | 143.83 | 376.83 | 10.55 | 0.00 | 91.67 |
July | 379.83 | 0.68 | 0.50 | 01-JUL-10:09 | 530.31 | 13.18 | 0.00 | 207.83 | 447.27 | 11.53 | 0.00 | 145.50 |
August | 372.50 | 0.68 | 0.50 | 01-AUG-08:50 | 596.27 | 12.53 | 0.00 | 194.50 | 520.02 | 10.94 | 0.00 | 142.33 |
September | 344.33 | 0.69 | 0.50 | 01-SEP-09:09 | 1385.39 | 11.43 | 0.00 | 173.50 | 1375.41 | 9.80 | 0.00 | 119.17 |
October | 347.33 | 0.74 | 0.50 | 01-OCT-10:00 | 404.52 | 9.13 | 0.00 | 100.83 | 336.04 | 7.64 | 0.00 | 59.67 |
November | 317.83 | 0.81 | 0.58 | 28-NOV-10:50 | 322.92 | 7.92 | 0.00 | 1.33 | 267.36 | 6.43 | 0.00 | 0.00 |
December | 315.50 | 0.81 | 0.58 | 08-DEC-11:39 | 315.35 | 7.96 | 0.00 | 8.33 | 259.31 | 6.48 | 0.00 | 0.00 |
Annual Sum or Average | 4237.50 | 0.73 | 680.21 | 10.42 | 0.00 | 1359.00 | 638.00 | 8.84 | 0.00 | 848.00 | ||
Minimum of Months | 303.83 | 0.68 | 0.50 | 315.35 | 7.92 | 0.00 | 1.33 | 259.31 | 6.43 | 0.00 | 0.00 | |
Maximum of Months | 406.00 | 0.81 | 0.58 | 2499.35 | 13.18 | 0.00 | 207.83 | 2685.86 | 11.53 | 0.00 | 145.50 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.522051E+09 | 54094.11 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 25148786.72 | 20049.52 | 02-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 32061701.07 | 34287.41 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.579261E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.522051E+09 | 54094.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.282267E+10 | 201322.21 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.189596E+09 | 119869.90 | 02-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.310982E+09 | 166194.13 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.332325E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.282267E+10 | 201322.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 79727644.42 | 17401.35 | 02-JAN-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3943413.29 | 9207.80 | 11-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 2505389.58 | 7502.51 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 86176447.29 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 79727644.42 | 17401.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.279871E+09 | 25726.13 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 35226057.59 | 16374.78 | 11-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 24506450.76 | 16393.09 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.339603E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.279871E+09 | 25726.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 4551550.33 | 1910.81 | 05-JAN-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1855596.04 | 1138.16 | 31-DEC-08:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 6407146.37 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 4551550.33 | 1910.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.136538E+10 | 0.110312E+10 | 6737.90 | 14-JAN-15:30 | 5124.36 | 0.00 |
February | 0.00 | 0.00 | 0.469750E+10 | 0.385281E+10 | 11234.88 | 24-FEB-16:00 | 9063.99 | 0.00 |
March | 0.00 | 0.00 | 0.128295E+11 | 0.108132E+11 | 45689.70 | 11-MAR-07:02 | 35169.03 | 0.00 |
April | 0.00 | 0.00 | 0.218246E+11 | 0.194145E+11 | 45827.45 | 17-APR-05:01 | 37443.18 | 0.00 |
May | 0.00 | 0.00 | 0.326912E+11 | 0.270593E+11 | 48447.03 | 24-MAY-05:02 | 28937.24 | 0.00 |
June | 0.00 | 0.00 | 0.363812E+11 | 0.277611E+11 | 49789.33 | 26-JUN-05:02 | 25077.94 | 0.00 |
July | 0.00 | 0.00 | 0.402475E+11 | 0.270634E+11 | 50086.14 | 20-JUL-05:02 | 24875.31 | 0.00 |
August | 0.00 | 0.00 | 0.396478E+11 | 0.257218E+11 | 49320.04 | 10-AUG-05:01 | 28775.75 | 0.00 |
September | 0.00 | 0.00 | 0.319947E+11 | 0.215089E+11 | 49408.84 | 03-SEP-07:02 | 27034.24 | 0.00 |
October | 0.00 | 0.00 | 0.209770E+11 | 0.169018E+11 | 47506.21 | 12-OCT-06:02 | 29477.73 | 0.00 |
November | 0.00 | 0.00 | 0.102371E+11 | 0.859145E+10 | 30053.89 | 09-NOV-07:02 | 21911.30 | 0.00 |
December | 0.00 | 0.00 | 0.298900E+10 | 0.245498E+10 | 7474.19 | 01-DEC-15:10 | 6806.06 | 0.00 |
Annual Sum or Average | 0.255883E+12 | 0.192246E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.136538E+10 | 0.110312E+10 | 6737.90 | 5124.36 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.402475E+11 | 0.277611E+11 | 50086.14 | 37443.18 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.742609E+10 | 0.602535E+10 | 32723.95 | 14-JAN-15:00 | 24146.13 | 0.00 |
February | 0.00 | 0.00 | 0.242587E+11 | 0.194743E+11 | 56353.94 | 24-FEB-15:40 | 43857.42 | 0.00 |
March | 0.00 | 0.00 | 0.646687E+11 | 0.526492E+11 | 197004.10 | 11-MAR-07:02 | 143499.23 | 0.00 |
April | 0.00 | 0.00 | 0.105631E+12 | 0.912189E+11 | 200918.47 | 26-APR-06:02 | 133850.83 | 0.00 |
May | 0.00 | 0.00 | 0.155112E+12 | 0.120944E+12 | 208440.29 | 24-MAY-06:02 | 114346.82 | 0.00 |
June | 0.00 | 0.00 | 0.174723E+12 | 0.120554E+12 | 214626.23 | 25-JUN-08:62 | 101461.68 | 0.00 |
July | 0.00 | 0.00 | 0.191375E+12 | 0.109198E+12 | 214894.55 | 28-JUL-06:02 | 100342.88 | 0.00 |
August | 0.00 | 0.00 | 0.190164E+12 | 0.101705E+12 | 216676.89 | 20-AUG-08:62 | 95921.18 | 0.00 |
September | 0.00 | 0.00 | 0.153009E+12 | 0.870980E+11 | 216736.40 | 10-SEP-08:62 | 94497.26 | 0.00 |
October | 0.00 | 0.00 | 0.952721E+11 | 0.713226E+11 | 206850.44 | 12-OCT-06:02 | 110870.10 | 0.00 |
November | 0.00 | 0.00 | 0.484043E+11 | 0.391660E+11 | 101740.86 | 11-NOV-09:02 | 70708.54 | 0.00 |
December | 0.00 | 0.00 | 0.139829E+11 | 0.112136E+11 | 37646.85 | 28-DEC-15:10 | 30924.30 | 0.00 |
Annual Sum or Average | 0.122403E+13 | 0.830568E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.742609E+10 | 0.602535E+10 | 32723.95 | 24146.13 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.191375E+12 | 0.120944E+12 | 216736.40 | 143499.23 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.444213E+10 | 0.385872E+10 | 8741.53 | 12-JAN-15:10 | 7961.40 | 0.00 |
February | 0.00 | 0.00 | 0.674889E+10 | 0.579430E+10 | 11017.39 | 22-FEB-14:20 | 9960.21 | 0.00 |
March | 0.00 | 0.00 | 0.118873E+11 | 0.102391E+11 | 29218.24 | 11-MAR-07:02 | 22411.63 | 0.00 |
April | 0.00 | 0.00 | 0.160677E+11 | 0.143298E+11 | 29681.60 | 17-APR-05:01 | 23801.28 | 0.00 |
May | 0.00 | 0.00 | 0.218750E+11 | 0.179106E+11 | 31440.98 | 24-MAY-05:02 | 18251.25 | 0.00 |
June | 0.00 | 0.00 | 0.240680E+11 | 0.179566E+11 | 32394.86 | 26-JUN-05:02 | 15891.21 | 0.00 |
July | 0.00 | 0.00 | 0.266999E+11 | 0.173426E+11 | 32473.27 | 20-JUL-05:02 | 15814.63 | 0.00 |
August | 0.00 | 0.00 | 0.267676E+11 | 0.167643E+11 | 31933.25 | 19-AUG-05:01 | 17733.61 | 0.00 |
September | 0.00 | 0.00 | 0.228489E+11 | 0.151662E+11 | 32172.00 | 03-SEP-07:02 | 16934.49 | 0.00 |
October | 0.00 | 0.00 | 0.177213E+11 | 0.145255E+11 | 30710.13 | 12-OCT-06:02 | 17995.54 | 0.00 |
November | 0.00 | 0.00 | 0.120162E+11 | 0.104453E+11 | 29107.08 | 09-NOV-07:02 | 22061.68 | 0.00 |
December | 0.00 | 0.00 | 0.627727E+10 | 0.544680E+10 | 9750.52 | 02-DEC-14:00 | 9308.17 | 0.00 |
Annual Sum or Average | 0.197420E+12 | 0.149780E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.444213E+10 | 0.385872E+10 | 8741.53 | 7961.40 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.267676E+11 | 0.179566E+11 | 32473.27 | 23801.28 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.199375E+10 | 0.169855E+10 | 6320.40 | 12-JAN-15:10 | 5603.66 | 0.00 |
February | 0.00 | 0.00 | 0.405275E+10 | 0.340303E+10 | 8717.19 | 22-FEB-14:20 | 7705.07 | 0.00 |
March | 0.00 | 0.00 | 0.858911E+10 | 0.721055E+10 | 24524.51 | 11-MAR-07:02 | 18053.09 | 0.00 |
April | 0.00 | 0.00 | 0.129274E+11 | 0.113359E+11 | 24803.07 | 24-APR-06:02 | 16784.84 | 0.00 |
May | 0.00 | 0.00 | 0.184496E+11 | 0.147417E+11 | 26265.43 | 24-MAY-05:02 | 14336.94 | 0.00 |
June | 0.00 | 0.00 | 0.205504E+11 | 0.147768E+11 | 27086.98 | 26-JUN-05:02 | 12388.71 | 0.00 |
July | 0.00 | 0.00 | 0.230627E+11 | 0.141665E+11 | 27133.08 | 20-JUL-05:02 | 12307.06 | 0.00 |
August | 0.00 | 0.00 | 0.230153E+11 | 0.135040E+11 | 26911.64 | 10-AUG-05:01 | 14096.10 | 0.00 |
September | 0.00 | 0.00 | 0.192943E+11 | 0.120824E+11 | 27025.41 | 10-SEP-08:62 | 11442.25 | 0.00 |
October | 0.00 | 0.00 | 0.143825E+11 | 0.114356E+11 | 25851.40 | 12-OCT-06:02 | 13846.85 | 0.00 |
November | 0.00 | 0.00 | 0.891186E+10 | 0.755061E+10 | 24119.21 | 11-NOV-09:02 | 18540.44 | 0.00 |
December | 0.00 | 0.00 | 0.337413E+10 | 0.283845E+10 | 7487.32 | 02-DEC-14:00 | 7031.89 | 0.00 |
Annual Sum or Average | 0.158604E+12 | 0.114744E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.199375E+10 | 0.169855E+10 | 6320.40 | 5603.66 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.230627E+11 | 0.147768E+11 | 27133.08 | 18540.44 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 5773673.52 | 0.00 | 788.45 | 03-JAN-08:04 | 0.93 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 4144970.45 | 0.00 | 788.45 | 21-DEC-08:04 | 0.93 |
Annual Sum or Average | 9918643.97 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5773673.52 | 0.00 | 788.45 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.153409E+10 | 0.33 | 2372.59 | 01-JAN-08:61 | 0.89 |
February | 0.138094E+10 | 0.33 | 1476.66 | 02-FEB-07:03 | 0.71 |
March | 0.154899E+10 | 0.33 | 2372.59 | 11-MAR-07:02 | 0.89 |
April | 0.150495E+10 | 0.33 | 2372.59 | 01-APR-06:02 | 0.89 |
May | 0.173393E+10 | 0.35 | 2372.59 | 01-MAY-05:02 | 0.90 |
June | 0.185947E+10 | 0.37 | 2372.59 | 01-JUN-05:02 | 0.89 |
July | 0.192202E+10 | 0.37 | 2372.59 | 01-JUL-05:01 | 0.89 |
August | 0.186608E+10 | 0.37 | 2372.59 | 01-AUG-05:01 | 0.88 |
September | 0.159567E+10 | 0.34 | 2372.59 | 01-SEP-05:01 | 0.88 |
October | 0.152967E+10 | 0.32 | 2372.59 | 01-OCT-07:02 | 0.89 |
November | 0.146580E+10 | 0.32 | 1422.03 | 09-NOV-07:02 | 0.69 |
December | 0.152462E+10 | 0.32 | 1851.35 | 23-DEC-07:03 | 0.80 |
Annual Sum or Average | 0.194662E+11 | 0.34 | |||
Minimum of Months | 0.138094E+10 | 0.32 | 1422.03 | 0.69 | |
Maximum of Months | 0.192202E+10 | 0.37 | 2372.59 | 0.90 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.833599E+10 | 0.51 | 12840.15 | 01-JAN-08:61 | 1.41 |
February | 0.747714E+10 | 0.51 | 9723.18 | 02-FEB-07:03 | 1.24 |
March | 0.838236E+10 | 0.52 | 12840.15 | 11-MAR-07:02 | 1.40 |
April | 0.831589E+10 | 0.53 | 12840.15 | 01-APR-06:02 | 1.41 |
May | 0.993871E+10 | 0.57 | 12840.15 | 01-MAY-05:02 | 1.41 |
June | 0.107048E+11 | 0.60 | 12840.15 | 01-JUN-05:02 | 1.40 |
July | 0.110094E+11 | 0.60 | 12840.15 | 01-JUL-05:01 | 1.40 |
August | 0.108505E+11 | 0.60 | 12840.15 | 01-AUG-05:01 | 1.39 |
September | 0.906877E+10 | 0.55 | 12840.15 | 01-SEP-05:01 | 1.39 |
October | 0.829155E+10 | 0.51 | 12840.15 | 01-OCT-08:62 | 1.40 |
November | 0.793219E+10 | 0.51 | 5583.20 | 11-NOV-09:02 | 0.90 |
December | 0.825836E+10 | 0.51 | 11495.89 | 23-DEC-07:03 | 1.34 |
Annual Sum or Average | 0.108566E+12 | 0.54 | |||
Minimum of Months | 0.747714E+10 | 0.51 | 5583.20 | 0.90 | |
Maximum of Months | 0.110094E+11 | 0.60 | 12840.15 | 1.41 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.891350E+09 | 0.34 | 1017.48 | 02-JAN-07:03 | 0.80 |
February | 0.807407E+09 | 0.34 | 799.76 | 11-FEB-07:03 | 0.70 |
March | 0.907271E+09 | 0.34 | 1387.69 | 11-MAR-07:02 | 0.92 |
April | 0.905109E+09 | 0.35 | 1387.69 | 01-APR-06:02 | 0.92 |
May | 0.104408E+10 | 0.37 | 1387.69 | 01-MAY-05:02 | 0.93 |
June | 0.110466E+10 | 0.39 | 1387.69 | 01-JUN-05:02 | 0.92 |
July | 0.114806E+10 | 0.39 | 1387.69 | 01-JUL-05:01 | 0.92 |
August | 0.114278E+10 | 0.39 | 1387.69 | 01-AUG-05:01 | 0.91 |
September | 0.101107E+10 | 0.37 | 1387.69 | 01-SEP-05:01 | 0.92 |
October | 0.937054E+09 | 0.35 | 1387.69 | 01-OCT-07:02 | 0.92 |
November | 0.858180E+09 | 0.33 | 1387.69 | 09-NOV-07:02 | 0.92 |
December | 0.891297E+09 | 0.34 | 754.44 | 23-DEC-07:03 | 0.68 |
Annual Sum or Average | 0.116483E+11 | 0.36 | |||
Minimum of Months | 0.807407E+09 | 0.33 | 754.44 | 0.68 | |
Maximum of Months | 0.114806E+10 | 0.39 | 1387.69 | 0.93 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.720134E+09 | 0.34 | 1112.47 | 01-JAN-08:61 | 0.92 |
February | 0.648106E+09 | 0.34 | 869.84 | 11-FEB-07:03 | 0.83 |
March | 0.726913E+09 | 0.34 | 1112.47 | 11-MAR-07:02 | 0.92 |
April | 0.725878E+09 | 0.35 | 1112.47 | 01-APR-06:02 | 0.92 |
May | 0.843697E+09 | 0.37 | 1112.47 | 01-MAY-05:02 | 0.93 |
June | 0.899501E+09 | 0.39 | 1112.47 | 01-JUN-06:02 | 0.92 |
July | 0.944270E+09 | 0.39 | 1112.47 | 01-JUL-05:01 | 0.92 |
August | 0.933891E+09 | 0.39 | 1112.47 | 01-AUG-05:01 | 0.91 |
September | 0.819927E+09 | 0.37 | 1112.47 | 01-SEP-05:01 | 0.91 |
October | 0.753852E+09 | 0.35 | 1112.47 | 01-OCT-07:02 | 0.92 |
November | 0.687749E+09 | 0.33 | 1112.47 | 11-NOV-09:02 | 0.92 |
December | 0.715110E+09 | 0.34 | 870.32 | 23-DEC-07:03 | 0.83 |
Annual Sum or Average | 0.941903E+10 | 0.36 | |||
Minimum of Months | 0.648106E+09 | 0.33 | 869.84 | 0.83 | |
Maximum of Months | 0.944270E+09 | 0.39 | 1112.47 | 0.93 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.08 | 5.19 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.31 | 0.00 |
May | 0.44 | 0.00 |
June | 0.90 | 0.00 |
July | 0.94 | 0.00 |
August | 1.83 | 0.00 |
September | 0.47 | 0.00 |
October | 0.15 | 0.00 |
November | 0.00 | 0.00 |
December | 0.08 | 6.13 |
Annual Sum or Average | 6.20 | 0.99 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.83 | 6.13 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.96 | 11.00 |
February | 0.83 | 5.17 |
March | 0.00 | 0.00 |
April | 0.31 | 0.00 |
May | 0.13 | 0.00 |
June | 0.21 | 0.00 |
July | 0.22 | 0.00 |
August | 0.53 | 0.00 |
September | 0.31 | 0.00 |
October | 0.00 | 0.00 |
November | 0.22 | 0.00 |
December | 1.00 | 2.15 |
Annual Sum or Average | 5.71 | 4.90 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.96 | 11.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.33 | 2.44 |
February | 0.28 | 0.00 |
March | 0.96 | 0.00 |
April | 2.25 | 0.00 |
May | 1.08 | 0.00 |
June | 1.80 | 0.00 |
July | 1.30 | 0.00 |
August | 2.27 | 0.00 |
September | 2.33 | 0.00 |
October | 1.34 | 0.00 |
November | 1.78 | 0.00 |
December | 0.14 | 0.00 |
Annual Sum or Average | 15.86 | 0.05 |
Minimum of Months | 0.14 | 0.00 |
Maximum of Months | 2.33 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.89 | 2.28 |
February | 0.17 | 2.44 |
March | 0.29 | 1.39 |
April | 1.73 | 0.71 |
May | 0.86 | 0.00 |
June | 0.99 | 0.00 |
July | 0.94 | 0.00 |
August | 2.08 | 0.00 |
September | 1.97 | 0.00 |
October | 1.09 | 0.37 |
November | 0.75 | 0.00 |
December | 0.06 | 0.00 |
Annual Sum or Average | 11.80 | 0.38 |
Minimum of Months | 0.06 | 0.00 |
Maximum of Months | 2.08 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 8.06 | 0.00 |
February | 2.82 | 0.00 |
March | 0.47 | 0.00 |
April | 3.36 | 0.00 |
May | 3.12 | 0.00 |
June | 2.99 | 0.00 |
July | 2.08 | 0.00 |
August | 1.44 | 0.00 |
September | 1.54 | 0.00 |
October | 2.33 | 0.00 |
November | 3.12 | 0.00 |
December | 7.26 | 0.00 |
Annual Sum or Average | 38.61 | 0.00 |
Minimum of Months | 0.47 | 0.00 |
Maximum of Months | 8.06 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.191044E+10 | 0.652563E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.266006E+10 | 31435983.39 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.505629E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.770559E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.110735E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.120132E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.123045E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.117641E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.962710E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.709160E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.423406E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.234169E+10 | 40077126.34 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.877823E+11 | 0.724076E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.191044E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.123045E+11 | 0.652563E+09 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.105658E+11 | 0.352834E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.146251E+11 | 0.236995E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.273312E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.404813E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.572829E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.621411E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.627622E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.605873E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.495015E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.355558E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.220920E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.124211E+11 | 0.388728E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.455347E+12 | 0.415407E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.105658E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.627622E+11 | 0.352834E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.201574E+10 | 99659555.52 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.249819E+10 | 4929266.62 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.394748E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.531991E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.718024E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.768310E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.788725E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.768869E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.661617E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.538712E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.380669E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.245870E+10 | 3131736.97 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.624893E+11 | 0.107721E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.201574E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.788725E+10 | 99659555.52 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.123686E+10 | 0.349838E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.168575E+10 | 44032571.99 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.295799E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.429332E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.599012E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.646310E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.669444E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.648963E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.551338E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.437505E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.290179E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.157630E+10 | 30633063.45 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.501777E+11 | 0.424504E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.123686E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.669444E+10 | 0.349838E+09 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.153409E+10 | 0.136538E+10 | 0.522051E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.138094E+10 | 0.469750E+10 | 25148786.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.154899E+10 | 0.128295E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.150495E+10 | 0.218246E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173393E+10 | 0.326912E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.185947E+10 | 0.363812E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.192202E+10 | 0.402475E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.186608E+10 | 0.396478E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.159567E+10 | 0.319947E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152967E+10 | 0.209770E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.146580E+10 | 0.102371E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.152462E+10 | 0.298900E+10 | 32061701.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.194662E+11 | 0.255883E+12 | 0.579261E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.138094E+10 | 0.136538E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.192202E+10 | 0.402475E+11 | 0.522051E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.833599E+10 | 0.742609E+10 | 0.282267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.747714E+10 | 0.242587E+11 | 0.189596E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.838236E+10 | 0.646687E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.831589E+10 | 0.105631E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.993871E+10 | 0.155112E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.107048E+11 | 0.174723E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.110094E+11 | 0.191375E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.108505E+11 | 0.190164E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.906877E+10 | 0.153009E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.829155E+10 | 0.952721E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.793219E+10 | 0.484043E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.825836E+10 | 0.139829E+11 | 0.310982E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.108566E+12 | 0.122403E+13 | 0.332325E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.747714E+10 | 0.742609E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.110094E+11 | 0.191375E+12 | 0.282267E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.891350E+09 | 0.444213E+10 | 79727644.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.807407E+09 | 0.674889E+10 | 3943413.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.907271E+09 | 0.118873E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.905109E+09 | 0.160677E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.104408E+10 | 0.218750E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.110466E+10 | 0.240680E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.114806E+10 | 0.266999E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.114278E+10 | 0.267676E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.101107E+10 | 0.228489E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.937054E+09 | 0.177213E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.858180E+09 | 0.120162E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.891297E+09 | 0.627727E+10 | 2505389.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116483E+11 | 0.197420E+12 | 86176447.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.807407E+09 | 0.444213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.114806E+10 | 0.267676E+11 | 79727644.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.720134E+09 | 0.199375E+10 | 0.279871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.648106E+09 | 0.405275E+10 | 35226057.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.726913E+09 | 0.858911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.725878E+09 | 0.129274E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.843697E+09 | 0.184496E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.899501E+09 | 0.205504E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.944270E+09 | 0.230627E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.933891E+09 | 0.230153E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.819927E+09 | 0.192943E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.753852E+09 | 0.143825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.687749E+09 | 0.891186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.715110E+09 | 0.337413E+10 | 24506450.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.941903E+10 | 0.158604E+12 | 0.339603E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.648106E+09 | 0.199375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.944270E+09 | 0.230627E+11 | 0.279871E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.153409E+10 | 0.00 | 0.00 | 0.00 | 0.376347E+09 | 0.00 | 0.652563E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.138094E+10 | 0.00 | 0.00 | 0.00 | 0.127912E+10 | 0.00 | 31435983.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.154899E+10 | 0.00 | 0.00 | 0.00 | 0.350730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.150495E+10 | 0.00 | 0.00 | 0.00 | 0.620064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173393E+10 | 0.00 | 0.00 | 0.00 | 0.933962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.185947E+10 | 0.00 | 0.00 | 0.00 | 0.101538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.192202E+10 | 0.00 | 0.00 | 0.00 | 0.103825E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.186608E+10 | 0.00 | 0.00 | 0.00 | 0.989804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.159567E+10 | 0.00 | 0.00 | 0.00 | 0.803144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152967E+10 | 0.00 | 0.00 | 0.00 | 0.556193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.146580E+10 | 0.00 | 0.00 | 0.00 | 0.276826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.152462E+10 | 0.00 | 0.00 | 0.00 | 0.817075E+09 | 0.00 | 40077126.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.194662E+11 | 0.00 | 0.00 | 0.00 | 0.683160E+11 | 0.00 | 0.724076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.138094E+10 | 0.00 | 0.00 | 0.00 | 0.376347E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.192202E+10 | 0.00 | 0.00 | 0.00 | 0.103825E+11 | 0.00 | 0.652563E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.833599E+10 | 0.00 | 0.00 | 0.00 | 0.222983E+10 | 0.00 | 0.352834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.747714E+10 | 0.00 | 0.00 | 0.00 | 0.714794E+10 | 0.00 | 0.236995E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.838236E+10 | 0.00 | 0.00 | 0.00 | 0.189489E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.831589E+10 | 0.00 | 0.00 | 0.00 | 0.321654E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.993871E+10 | 0.00 | 0.00 | 0.00 | 0.473442E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.107048E+11 | 0.00 | 0.00 | 0.00 | 0.514363E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.110094E+11 | 0.00 | 0.00 | 0.00 | 0.517527E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.108505E+11 | 0.00 | 0.00 | 0.00 | 0.497367E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.906877E+10 | 0.00 | 0.00 | 0.00 | 0.404327E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.829155E+10 | 0.00 | 0.00 | 0.00 | 0.272643E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.793219E+10 | 0.00 | 0.00 | 0.00 | 0.141598E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.825836E+10 | 0.00 | 0.00 | 0.00 | 0.416277E+10 | 0.00 | 0.388728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.108566E+12 | 0.00 | 0.00 | 0.00 | 0.346782E+12 | 0.00 | 0.415407E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.747714E+10 | 0.00 | 0.00 | 0.00 | 0.222983E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.110094E+11 | 0.00 | 0.00 | 0.00 | 0.517527E+11 | 0.00 | 0.352834E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.891350E+09 | 0.00 | 0.00 | 0.00 | 0.112439E+10 | 0.00 | 99659555.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.807407E+09 | 0.00 | 0.00 | 0.00 | 0.169078E+10 | 0.00 | 4929266.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.907271E+09 | 0.00 | 0.00 | 0.00 | 0.304021E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.905109E+09 | 0.00 | 0.00 | 0.00 | 0.441480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.104408E+10 | 0.00 | 0.00 | 0.00 | 0.613617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.110466E+10 | 0.00 | 0.00 | 0.00 | 0.657844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.114806E+10 | 0.00 | 0.00 | 0.00 | 0.673919E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.114278E+10 | 0.00 | 0.00 | 0.00 | 0.654591E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.101107E+10 | 0.00 | 0.00 | 0.00 | 0.560511E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.937054E+09 | 0.00 | 0.00 | 0.00 | 0.445007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.858180E+09 | 0.00 | 0.00 | 0.00 | 0.294851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.891297E+09 | 0.00 | 0.00 | 0.00 | 0.156741E+10 | 0.00 | 3131736.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116483E+11 | 0.00 | 0.00 | 0.00 | 0.508410E+11 | 0.00 | 0.107721E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.807407E+09 | 0.00 | 0.00 | 0.00 | 0.112439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.114806E+10 | 0.00 | 0.00 | 0.00 | 0.673919E+10 | 0.00 | 99659555.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.720134E+09 | 0.00 | 0.00 | 0.00 | 0.516723E+09 | 0.00 | 0.349838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.648106E+09 | 0.00 | 0.00 | 0.00 | 0.103765E+10 | 0.00 | 44032571.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.726913E+09 | 0.00 | 0.00 | 0.00 | 0.223108E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.725878E+09 | 0.00 | 0.00 | 0.00 | 0.356744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.843697E+09 | 0.00 | 0.00 | 0.00 | 0.514643E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.899501E+09 | 0.00 | 0.00 | 0.00 | 0.556360E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.944270E+09 | 0.00 | 0.00 | 0.00 | 0.575017E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.933891E+09 | 0.00 | 0.00 | 0.00 | 0.555573E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.819927E+09 | 0.00 | 0.00 | 0.00 | 0.469345E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.753852E+09 | 0.00 | 0.00 | 0.00 | 0.362120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.687749E+09 | 0.00 | 0.00 | 0.00 | 0.221404E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.715110E+09 | 0.00 | 0.00 | 0.00 | 0.861194E+09 | 0.00 | 30633063.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.941903E+10 | 0.00 | 0.00 | 0.00 | 0.407587E+11 | 0.00 | 0.424504E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.648106E+09 | 0.00 | 0.00 | 0.00 | 0.516723E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.944270E+09 | 0.00 | 0.00 | 0.00 | 0.575017E+10 | 0.00 | 0.349838E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.313658E+10 | 0.00 | 0.00 | 2471984.05 | 0.00 | 0.325102E+09 | 0.157204E+10 | 0.00 | 0.22 |
February | 0.129399E+10 | 16354014.37 | 0.00 | 6338602.53 | 0.00 | 6946076.35 | 0.145378E+10 | 0.00 | 0.22 |
March | 0.330230E+09 | 0.992748E+09 | 0.00 | 6868541.32 | 2641768.46 | 0.00 | 0.653494E+09 | 0.00 | 0.23 |
April | 26337976.15 | 0.342973E+10 | 0.00 | 1411992.45 | 49834595.17 | 0.00 | 27557079.65 | 0.00 | 0.22 |
May | 0.00 | 0.807829E+10 | 0.00 | 85755.10 | 64921633.09 | 0.00 | 0.00 | 0.00 | 0.23 |
June | 0.00 | 0.109100E+11 | 0.00 | 0.00 | 88832248.02 | 0.00 | 0.00 | 0.00 | 0.23 |
July | 0.00 | 0.138686E+11 | 0.00 | 0.00 | 94448778.55 | 0.00 | 0.00 | 0.00 | 0.23 |
August | 0.00 | 0.142511E+11 | 0.00 | 0.00 | 0.102764E+09 | 0.00 | 0.00 | 0.00 | 0.23 |
September | 0.00 | 0.106344E+11 | 0.00 | 0.00 | 0.121576E+09 | 0.00 | 0.00 | 0.00 | 0.23 |
October | 67692729.57 | 0.355909E+10 | 0.00 | 1818606.43 | 54843685.40 | 0.00 | 54391812.79 | 0.00 | 0.22 |
November | 0.541578E+09 | 0.387359E+09 | 0.00 | 7973616.71 | 0.00 | 0.00 | 0.854704E+09 | 0.00 | 0.22 |
December | 0.241277E+10 | 0.00 | 0.00 | 5415635.74 | 0.00 | 10389227.01 | 0.196979E+10 | 0.00 | 0.22 |
Annual Sum or Average | 0.780918E+10 | 0.661276E+11 | 0.00 | 32384734.32 | 0.579863E+09 | 0.342437E+09 | 0.658576E+10 | 0.00 | 0.22 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.22 |
Maximum of Months | 0.313658E+10 | 0.142511E+11 | 0.00 | 7973616.71 | 0.121576E+09 | 0.325102E+09 | 0.196979E+10 | 0.00 | 0.23 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.219437E+11 | 0.00 | 0.00 | 17840012.39 | 0.00 | 0.105704E+10 | 0.110577E+11 | 0.00 | 0.42 |
February | 0.930898E+10 | 0.438885E+09 | 0.00 | 31334710.58 | 0.00 | 37148951.23 | 0.852172E+10 | 0.00 | 0.43 |
March | 0.244512E+10 | 0.102339E+11 | 0.00 | 27754322.73 | 32128846.89 | 0.00 | 0.325056E+10 | 0.00 | 0.44 |
April | 0.111010E+09 | 0.310190E+11 | 0.00 | 3689700.05 | 0.561849E+09 | 0.00 | 0.130320E+09 | 0.00 | 0.44 |
May | 0.00 | 0.654358E+11 | 0.00 | 173035.94 | 0.750728E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
June | 0.00 | 0.851079E+11 | 0.00 | 0.00 | 0.965889E+09 | 0.00 | 0.00 | 0.00 | 0.44 |
July | 0.00 | 0.105351E+12 | 0.00 | 0.00 | 0.118237E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
August | 0.00 | 0.106251E+12 | 0.00 | 0.00 | 0.142606E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
September | 0.00 | 0.786926E+11 | 0.00 | 0.00 | 0.153387E+10 | 0.00 | 0.00 | 0.00 | 0.44 |
October | 0.566076E+09 | 0.286867E+11 | 0.00 | 6747407.05 | 0.533923E+09 | 0.00 | 0.651986E+09 | 0.00 | 0.43 |
November | 0.477651E+10 | 0.506951E+10 | 0.00 | 28350724.72 | 0.00 | 0.00 | 0.452508E+10 | 0.00 | 0.43 |
December | 0.173934E+11 | 182795.41 | 0.00 | 29747202.71 | 0.00 | 70606710.59 | 0.118471E+11 | 0.00 | 0.42 |
Annual Sum or Average | 0.565449E+11 | 0.516286E+12 | 0.00 | 0.145637E+09 | 0.698682E+10 | 0.116479E+10 | 0.399844E+11 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.219437E+11 | 0.106251E+12 | 0.00 | 31334710.58 | 0.153387E+10 | 0.105704E+10 | 0.118471E+11 | 0.00 | 0.44 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.117851E+10 | 118118.90 | 0.00 | 10310177.30 | 0.00 | 40510124.17 | 0.173403E+10 | 0.00 | 0.42 |
February | 0.551281E+09 | 0.147456E+09 | 0.00 | 8484647.67 | 0.00 | 868234.77 | 0.807787E+09 | 0.00 | 0.43 |
March | 0.139088E+09 | 0.129806E+10 | 0.00 | 4552837.39 | 666806.87 | 0.00 | 0.272868E+09 | 0.00 | 0.44 |
April | 7353677.13 | 0.328987E+10 | 0.00 | 567958.88 | 29254597.53 | 0.00 | 13708396.94 | 0.00 | 0.43 |
May | 0.00 | 0.675943E+10 | 0.00 | 25218.85 | 46115978.70 | 0.00 | 8840.66 | 0.00 | 0.44 |
June | 0.00 | 0.885430E+10 | 0.00 | 0.00 | 56549265.32 | 0.00 | 0.00 | 0.00 | 0.44 |
July | 0.00 | 0.110902E+11 | 0.00 | 0.00 | 63651349.33 | 0.00 | 0.00 | 0.00 | 0.44 |
August | 0.00 | 0.113748E+11 | 0.00 | 0.00 | 77618810.33 | 0.00 | 0.00 | 0.00 | 0.44 |
September | 0.00 | 0.873970E+10 | 0.00 | 0.00 | 90575866.33 | 0.00 | 0.00 | 0.00 | 0.44 |
October | 14850086.36 | 0.358296E+10 | 0.00 | 1248743.96 | 20894855.79 | 0.00 | 38764606.86 | 0.00 | 0.43 |
November | 0.202454E+09 | 0.874247E+09 | 0.00 | 6545932.76 | 0.00 | 0.00 | 0.406977E+09 | 0.00 | 0.43 |
December | 0.839253E+09 | 11991541.93 | 0.00 | 12636366.77 | 0.00 | 525136.78 | 0.148376E+10 | 0.00 | 0.43 |
Annual Sum or Average | 0.293279E+10 | 0.560231E+11 | 0.00 | 44371883.58 | 0.385328E+09 | 41903495.72 | 0.475791E+10 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 118118.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.117851E+10 | 0.113748E+11 | 0.00 | 12636366.77 | 90575866.33 | 40510124.17 | 0.173403E+10 | 0.00 | 0.44 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.173930E+10 | 0.00 | 0.00 | 4479879.69 | 0.00 | 0.127379E+09 | 0.122008E+10 | 0.00 | 0.42 |
February | 0.844720E+09 | 96234813.09 | 0.00 | 4779557.06 | 0.00 | 10596219.14 | 0.668419E+09 | 0.00 | 0.43 |
March | 0.246589E+09 | 0.114335E+10 | 0.00 | 3107025.48 | 974667.42 | 0.00 | 0.245398E+09 | 0.00 | 0.44 |
April | 10644491.83 | 0.314294E+10 | 0.00 | 358109.47 | 38453314.37 | 0.00 | 12398478.57 | 0.00 | 0.43 |
May | 0.00 | 0.651040E+10 | 0.00 | 40566.43 | 54348267.14 | 0.00 | 0.00 | 0.00 | 0.44 |
June | 0.00 | 0.852081E+10 | 0.00 | 0.00 | 62506741.26 | 0.00 | 0.00 | 0.00 | 0.44 |
July | 0.00 | 0.106600E+11 | 0.00 | 0.00 | 64735020.78 | 0.00 | 0.00 | 0.00 | 0.44 |
August | 0.00 | 0.109026E+11 | 0.00 | 0.00 | 78265762.01 | 0.00 | 0.00 | 0.00 | 0.44 |
September | 0.00 | 0.828207E+10 | 0.00 | 0.00 | 88717737.20 | 0.00 | 0.00 | 0.00 | 0.44 |
October | 30734104.40 | 0.335304E+10 | 0.00 | 915229.73 | 24692776.76 | 0.00 | 41054900.08 | 0.00 | 0.43 |
November | 0.299193E+09 | 0.775995E+09 | 0.00 | 4521266.64 | 0.00 | 0.00 | 0.399371E+09 | 0.00 | 0.43 |
December | 0.124621E+10 | 4232070.38 | 0.00 | 6962715.52 | 0.00 | 4159409.00 | 0.126725E+10 | 0.00 | 0.43 |
Annual Sum or Average | 0.441740E+10 | 0.533917E+11 | 0.00 | 25164350.00 | 0.412694E+09 | 0.142135E+09 | 0.385397E+10 | 0.00 | 0.43 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.173930E+10 | 0.109026E+11 | 0.00 | 6962715.52 | 88717737.20 | 0.127379E+09 | 0.126725E+10 | 0.00 | 0.44 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:43
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |