Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2020-06-03 19:13:11
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2556.21 | 1114.30 | 1114.30 |
Net Site Energy | 2556.21 | 1114.30 | 1114.30 |
Total Source Energy | 5649.98 | 2462.95 | 2462.95 |
Net Source Energy | 5649.98 | 2462.95 | 2462.95 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 1073.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 134.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 475.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 72.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 504.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 100.74 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1382.17 | 1174.04 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 1073.29 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 134.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 475.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 72.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 504.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 100.74 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 238.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 278.54 | 511.79 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 602.52 | 511.79 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 238.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 278.54 | 511.79 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 602.52 | 511.79 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1382.169 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1382.169 | 100.00 |
Total On-Site and Utility Electric Sources | 1382.169 | 100.00 |
Total Electricity End Uses | 1382.169 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2367.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13 |
RunPeriod | RUNPERIOD 1 |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Latitude [deg] | 48.57 |
Longitude [deg] | -93.4 |
Elevation [m] | 359.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 6.69 |
Skylight-Roof Ratio [%] | 0.29 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 8.3451 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 17.7333 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 17.7333 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 17.7333 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 13.5608 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.1568 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 16.1568 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-JUN-15:00 | 09-JAN-05:10 | - | - | - | 03-NOV-11:09 |
Heating | 0.00 | 427201.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 56833.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 33384.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 19294.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 120284.19 | 429063.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 427201.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 56833.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 33384.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 19294.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1163.45 | 0.00 | 0.00 | 0.00 |
Cooling | 425.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1505.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 230.59 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1597.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 109.21 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4377.33 | 1272.66 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 507.17 | 0.00 | 0.00 | 0.00 |
Cooling | 185.62 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 656.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 100.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 696.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 47.61 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1908.17 | 554.78 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 507.17 | 0.00 | 0.00 | 0.00 |
Cooling | 185.62 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 656.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 100.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 696.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 47.61 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1908.17 | 554.78 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 1.72 |
CORE_RETAIL DIRECT AIR | 7.85 |
POINT_OF_SALE DIRECT AIR | 1.22 |
FRONT_RETAIL DIRECT AIR | 0.979026 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 5.87 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 5.87 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 131506.17 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 52518.30 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 291316.88 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 38019.41 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 32716.83 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 1.72 | 1.72 | 1.72 | 1.72 | 1.77 | 1.77 | 1.00 | 0.976556 | 1.77 |
PSZ-AC:2 | 7.85 | 7.85 | 7.85 | 7.85 | 8.03 | 8.03 | 1.00 | 0.976543 | 8.03 |
PSZ-AC:3 | 1.22 | 1.22 | 1.22 | 1.22 | 1.22 | 1.22 | 1.00 | 1.00 | 1.22 |
PSZ-AC:4 | 0.979026 | 0.979026 | 0.979026 | 0.979026 | 0.979026 | 0.979026 | 1.00 | 1.000000 | 0.979026 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 1.77 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 8.03 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.22 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 0.979026 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 1.77 | 1.77 | 1.77 | 1.77 | 33675.79 | 52518.30 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 8.03 | 8.03 | 8.03 | 8.03 | 163714.62 | 291316.88 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.22 | 1.22 | 1.22 | 1.22 | 22163.77 | 38019.41 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 0.979026 | 0.979026 | 0.979026 | 0.979026 | 18587.77 | 32716.83 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 1.77 | 0.883185 | 1.77 | 31425.96 | 33675.79 | 16837.90 | 33675.79 | 0.750224 | 0.750220 | 0.750220 | 0.750220 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 8.03 | 4.02 | 8.03 | 153656.30 | 163714.62 | 81857.31 | 163714.62 | 0.729669 | 0.729670 | 0.729670 | 0.729670 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.22 | 0.609465 | 1.22 | 20594.58 | 22163.77 | 11081.89 | 22163.77 | 0.765709 | 0.765710 | 0.765710 | 0.765710 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 0.979030 | 0.489515 | 0.979030 | 17340.25 | 18587.77 | 9293.89 | 18587.77 | 0.751554 | 0.751550 | 0.751550 | 0.751550 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.77 | 1933.30 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 8.03 | 14855.76 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.22 | 1389.72 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.979026 | 1116.20 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R2C4 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C3 | SKYLIGHTS_R1C3 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C2 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 5.40 | -2.00 | -14.60 | -16.90 | -11.50 | -6.20 | 4.00 | 13.40 | 18.00 | 19.70 | 17.90 | 12.30 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | International Falls Intl Ap MN USA TMY3 WMO#=727470 | 48.57 | -93.40 | -6.00 | 359.00 | 97086 | 1.1539 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 3.29 | 36.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 65 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 6.69 | 10 | 14 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 8.345 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 16.415 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 17.733 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 20.963 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 17.733 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 39.253 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 17.733 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 20.963 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 13.561 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 13.561 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 3170.217 | 8.345 | 51.681 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 3170.217 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 28381.872 | 17.733 | 109.822 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 28381.872 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2674.362 | 17.733 | 109.822 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2674.362 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2674.362 | 17.733 | 109.822 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2674.362 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 162.729 | 13.561 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 162.729 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2284 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.4290 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1659 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.3309E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1913 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1913 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.3147 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.163 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.950 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 30.14 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.149 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.149 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.101 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.8391346 | 2.8391346 | 2.8391346 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 2.8391346 | 2.8391346 | 2.8391346 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
21 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
22 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
23 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
24 | 9 | 0.21485751E-14 | -0.22894401E-15 | -0.17283669E-09 | -0.31350098E-16 |
25 | 8 | 0.25115787E-07 | 0.58773152E-13 | 0.41104347E-03 | -0.28557513E-09 |
26 | 7 | -0.13231082E-01 | 0.29616277E-08 | -0.24509747E-01 | 0.15044224E-03 |
27 | 6 | 0.43223401 | 0.10185882E-05 | 0.49492235 | -0.50646574E-02 |
28 | 5 | -5.4528708 | 0.37659386E-04 | -4.6163278 | 0.66436381E-01 |
29 | 4 | 34.162830 | 0.30532126E-03 | 22.123982 | -0.43752457 |
30 | 3 | -113.69342 | 0.66011806E-03 | -56.975280 | 1.5508408 |
31 | 2 | 199.57555 | 0.36866733E-03 | 79.115267 | -2.9395356 |
32 | 1 | -172.06709 | 0.39096546E-04 | -55.617513 | 2.7614060 |
33 | 0 | 57.057407 | 0.22087022E-06 | 15.500460 | |
34 | 7 | -0.25528060E-08 | -0.12031403E-14 | 0.68407999E-14 | -0.93970880E-16 |
35 | 6 | 0.47134542E-05 | 0.31734324E-08 | 0.31924928E-02 | -0.26781305E-04 |
36 | 5 | -0.33464294E-03 | 0.18778732E-05 | -0.22387365 | 0.19574661E-02 |
37 | 4 | 0.76699050E-02 | 0.85441795E-04 | 4.8320287 | -0.45288849E-01 |
38 | 3 | -0.67267585E-01 | 0.67916014E-03 | -38.035443 | 0.39880879 |
39 | 2 | 0.23873650 | 0.11294419E-02 | 116.51125 | -1.4183045 |
40 | 1 | -0.34450630 | 0.34392527E-03 | -143.92338 | 2.0493041 |
41 | 0 | 0.16794560 | 0.83374149E-05 | 60.838472 | |
42 | 7 | -0.12973758E-07 | 0.34411372E-14 | -0.15771944E-13 | 0.23851239E-15 |
43 | 6 | 0.18530215E-05 | 0.67214774E-09 | 0.32028229E-02 | -0.26867962E-04 |
44 | 5 | -0.88022991E-04 | 0.38590341E-06 | -0.22446025 | 0.19626440E-02 |
45 | 4 | 0.17210852E-02 | 0.17282655E-04 | 4.8417890 | -0.45382682E-01 |
46 | 3 | -0.14132592E-01 | 0.13559951E-03 | -38.090529 | 0.39941776 |
47 | 2 | 0.48779578E-01 | 0.22269637E-03 | 116.61840 | -1.4197378 |
48 | 1 | -0.69488798E-01 | 0.66762873E-04 | -143.98642 | 2.0503404 |
49 | 0 | 0.33651223E-01 | 0.15845250E-05 | 60.838472 | |
50 | 7 | -0.22078744E-08 | -0.78010070E-15 | 0.51210754E-14 | -0.71692469E-16 |
51 | 6 | 0.53924046E-05 | 0.36628569E-08 | 0.31905048E-02 | -0.26764628E-04 |
52 | 5 | -0.38538745E-03 | 0.21680609E-05 | -0.22376067 | 0.19564689E-02 |
53 | 4 | 0.88497020E-02 | 0.98671011E-04 | 4.8301469 | -0.45270761E-01 |
54 | 3 | -0.77667315E-01 | 0.78446833E-03 | -38.024813 | 0.39869130 |
55 | 2 | 0.27571886 | 0.13048573E-02 | 116.49056 | -1.4180278 |
56 | 1 | -0.39792016 | 0.39739385E-03 | -143.91120 | 2.0491039 |
57 | 0 | 0.19399612 | 0.96507839E-05 | 60.838472 | |
58 | 7 | -0.22078744E-08 | -0.78010070E-15 | 0.51210754E-14 | -0.71692469E-16 |
59 | 6 | 0.53924046E-05 | 0.36628569E-08 | 0.31905048E-02 | -0.26764628E-04 |
60 | 5 | -0.38538745E-03 | 0.21680609E-05 | -0.22376067 | 0.19564689E-02 |
61 | 4 | 0.88497020E-02 | 0.98671011E-04 | 4.8301469 | -0.45270761E-01 |
62 | 3 | -0.77667315E-01 | 0.78446833E-03 | -38.024813 | 0.39869130 |
63 | 2 | 0.27571886 | 0.13048573E-02 | 116.49056 | -1.4180278 |
64 | 1 | -0.39792016 | 0.39739385E-03 | -143.91120 | 2.0491039 |
65 | 0 | 0.19399612 | 0.96507839E-05 | 60.838472 | |
66 | 7 | -0.13255510E-08 | -0.17188199E-15 | 0.92128295E-14 | -0.12705258E-15 |
67 | 6 | 0.87884716E-05 | 0.60547316E-08 | 0.31807701E-02 | -0.26682965E-04 |
68 | 5 | -0.63593173E-03 | 0.35898785E-05 | -0.22320731 | 0.19515846E-02 |
69 | 4 | 0.14651324E-01 | 0.16347926E-03 | 4.8209294 | -0.45182156E-01 |
70 | 3 | -0.12872491 | 0.13006479E-02 | -37.972737 | 0.39811570 |
71 | 2 | 0.45715725 | 0.21644648E-02 | 116.38920 | -1.4166720 |
72 | 1 | -0.65988557 | 0.65992538E-03 | -143.85153 | 2.0481231 |
73 | 0 | 0.32173707 | 0.15909640E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.41_SHGC_0.45 | 30 | 1 | VerySmooth | 2.330 | 0.445 | 0.367 | 0.451 |
2 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 31 | 1 | VerySmooth | 3.411 | 0.396 | 0.314 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 3.14065E-002 | 0.36619 | 0.42864 | 0.42864 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 0.12199 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.31383 | 0.45189 | 0.45189 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 1.61274E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1913 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
31 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
32 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
33 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
34 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 2 | No | No |
39 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 1.87E-002 | 0 | No | No |
40 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
41 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
42 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
43 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
44 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
45 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
46 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
47 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
48 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
49 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
50 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
52 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
53 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
54 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
58 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
59 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
60 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
61 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
62 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
63 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
64 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
65 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.448 | 1.180E-003 | 5.356E-004 | 0.697 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.367 | 2.293E-004 | 1.864E-004 | 0.135 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 2.497E-002 | 2.080E-003 | 6.862E-004 | 1.228 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 1.419 | 0.118 | 3.899E-002 | 69.771 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 19569.38669 | 23483.26403 | 1.43746 | 1.72496 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 20.92400 | 1.27032E-002 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 30213.55503 | 36256.26604 | 1.33401 | 1.60081 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 88785.64875 | 106542.77850 | 6.53817 | 7.84580 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 20.92400 | 1.27032E-002 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 70784.10151 | 84940.92181 | 3.08310 | 3.69972 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 13264.69463 | 15917.63356 | 1.01578 | 1.21893 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79000 | 1.27032E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 14836.95720 | 17804.34864 | 0.65703 | 0.78843 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 10653.95246 | 12784.74295 | 0.81585 | 0.97903 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 29.79000 | 1.27032E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 14836.29316 | 17803.55179 | 0.65700 | 0.78840 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10000 | 1.27032E-002 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 109469.47336 | 131363.36803 | 4.89144 | 5.86973 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | -32.70000 | 1.83376E-004 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 22317.60 | 1.76637 | 1.76637 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 49775.26 | 1.60081 | 1.60081 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 108721.51 | 8.03426 | 8.03426 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 199439.58 | 3.69972 | 3.69972 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 16897.16 | 1.21893 | 1.21893 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 28504.15 | 0.78843 | 0.78843 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 13823.87 | 0.97903 | 0.97903 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 28503.36 | 0.78840 | 0.78840 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.72496 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 7.84580 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.21893 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.97903 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 5.86973 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 5.86973 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 131506.17238 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.72496 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.72496 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.72496 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.72496 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.76637 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.76637 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.97656 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 7.84580 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 7.84580 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 7.84580 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 7.84580 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 8.03426 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 8.03426 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.97654 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.21893 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.21893 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.21893 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.21893 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.21893 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.21893 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.97903 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.97903 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.97903 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.97903 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.97903 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.97903 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 1.76637 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 8.03426 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.21893 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 0.97903 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.76637 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.76637 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.76637 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.76637 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.76637 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.76637 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.88319 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.76637 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 31425.95885 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 33675.79000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 16837.89500 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 33675.79000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.75022 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.75022 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.75022 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.75022 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 33675.79000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 52518.29514 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.76637 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1933.29811 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 52518.29514 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 8.03426 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 8.03426 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 8.03426 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 8.03426 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 8.03426 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 8.03426 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 4.01713 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 8.03426 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 153656.30005 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 163714.62000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 81857.31000 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 163714.62000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72967 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72967 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72967 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72967 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 163714.62000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 291316.87528 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 8.03426 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 14855.75677 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 291316.87528 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.21893 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.21893 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.21893 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.21893 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.21893 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.21893 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.60947 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.21893 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 20594.57716 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 22163.77000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11081.88500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 22163.77000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.76571 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.76571 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.76571 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.76571 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 22163.77000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 38019.41059 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.21893 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1389.71524 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 38019.41059 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.97903 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.97903 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.97903 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.97903 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.97903 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.97903 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.48952 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.97903 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 17340.25100 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 18587.77000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 9293.88500 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 18587.77000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.75155 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.75155 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.75155 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.75155 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 18587.77000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 32716.82589 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.97903 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1116.19680 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 32716.82589 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 32288.7 | 10.25 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 157398.8 | 11.63 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 21207.2 | 101.19 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 17819.0 | 144.56 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 25 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.839 | 2.839 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.839 | 2.839 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.839 | 2.839 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.839 | 2.839 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 2.839 | 2.839 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.166 | 0.159 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.839 | 2.839 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 3.309E-002 | 3.283E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 1593.79 | 1600.48 | 1593.79 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
32 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
33 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
34 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | N/A | 3.411 | No | 0.84 | 0.84 | 0.84 | 270.00 | 0.00 | 0.91 | 0.91 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
40 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
41 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.41_SHGC_0.45 | N/A | 2.330 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
45 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.191 | 0.183 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.41_SHGC_0.45 | N/A | 2.330 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
54 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.191 | 0.183 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
56 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
57 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
58 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.429 | 0.403 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.41_SHGC_0.45 | N/A | 2.330 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.315 | 0.292 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 7 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 0.3446045050 | 0.5740989852 | Pass | Pass | 0.2946727389 | 0.4595024271 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 0.1204930673 | 0.4168929551 | Pass | Pass | 5.5116581564E-002 | 0.2208199938 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 0.3325983463 | 0.6467703972 | Pass | Pass | 0.3581906373 | 0.5155936863 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 0.3466007784 | 0.6361859369 | Pass | Pass | 0.3233826132 | 0.4873620757 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.2564270220 | 0.4792660676 | Pass | Pass | 9.2924040355E-002 | 0.5050408972 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 1600.48 | 1593.79 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.403 | 0.429 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.166 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.033 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.191 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.191 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.315 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.6_SHGC_0.4 | 0.84 | 0.00 | 0.00 | 0.84 | 0.84 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 270.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.41_SHGC_0.45 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.330 | 0.445 | 0.451 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.41_SHGC_0.45 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.330 | 0.445 | 0.451 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.41_SHGC_0.45 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.330 | 0.445 | 0.451 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 90.63 | 2.410 | 0.441 | 0.447 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 90.63 | 2.410 | 0.441 | 0.447 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 8.3451 | 379.89 | 3170.22 | LightsWired | BLDG_LIGHT_BACK_SCH | 69.84 | 168.00 | 68.87 | 0.0000 | Y | 40.98 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 17.7333 | 1600.48 | 28381.87 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 363.63 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 17.7333 | 150.81 | 2674.36 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 34.26 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 17.7333 | 150.81 | 2674.36 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 34.26 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 13.5608 | 12.00 | 162.73 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 2.08 |
Interior Lighting Total | 16.1568 | 2293.99 | 37063.54 | 475.23 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 4644.36 | AstronomicalClock | - | 83.52 | 83.52 | 72.81 | |
Exterior Lighting Total | 4644.36 | 72.81 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 33675.79 | 25264.25 | 8411.54 | 0.75 | 3.50 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 163714.62 | 119457.65 | 44256.97 | 0.73 | 3.23 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 22163.77 | 16971.02 | 5192.75 | 0.77 | 3.50 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 18587.77 | 13969.64 | 4618.13 | 0.75 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 32288.7 | 10.25 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 157398.8 | 11.63 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 21207.2 | 101.19 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 17819.0 | 144.56 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 131506.17 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 52518.30 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 291316.88 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 38019.41 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 32716.83 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.59 | 1110.54 | 5.87 | 11020.40 | 1877.50 | 1.00 | 1.13 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.57 | 622.50 | 1.77 | 1933.30 | 1094.51 | 1.00 | 1.30 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1110.54 | 8.03 | 14855.76 | 1849.05 | 1.00 | 1.14 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 1.22 | 1389.72 | 1140.11 | 1.00 | 1.32 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.55 | 622.50 | 0.98 | 1116.20 | 1140.11 | 1.00 | 1.37 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 19569.39 | 23483.26 | 61.82 | 1.437 | 1.725 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.88 | 0.01007 | 20.92 | 0.01270 | 0.232 | 0.00 |
CORE_RETAIL | 88785.65 | 106542.78 | 66.57 | 6.538 | 7.846 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00969 | 20.92 | 0.01270 | 1.890 | 0.00 |
POINT_OF_SALE | 13264.69 | 15917.63 | 105.55 | 1.016 | 1.219 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 23.89 | 23.89 | 0.00896 | 29.79 | 0.01270 | 0.178 | 0.00 |
FRONT_RETAIL | 10653.95 | 12784.74 | 84.77 | 0.816 | 0.979 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 23.89 | 23.89 | 0.00907 | 29.79 | 0.01270 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.06 | 100.00 | 0.00001 | 30.10 | 0.01270 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 30213.56 | 36256.27 | 95.44 | 1.334 | 1.601 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00780 | -32.70 | 0.00018 | 0.232 | 0.00 |
CORE_RETAIL | 70784.10 | 84940.92 | 53.07 | 3.083 | 3.700 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00774 | -32.70 | 0.00018 | 1.890 | 0.00 |
POINT_OF_SALE | 14836.96 | 17804.35 | 118.06 | 0.657 | 0.788 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00785 | -32.70 | 0.00018 | 0.178 | 0.00 |
FRONT_RETAIL | 14836.29 | 17803.55 | 118.05 | 0.657 | 0.788 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00785 | -32.70 | 0.00018 | 0.178 | 0.00 |
FRONT_ENTRY | 109469.47 | 131363.37 | 10946.95 | 4.891 | 5.870 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | 21.11 | 20.96 | 0.00596 | -32.70 | 0.00018 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 1.77 | 1.77 | 1.60 | 1.60 | 1.7664 | 1.7250 | 1.7664 | 0.9766 | 1.0000 |
PSZ-AC:2 | 8.03 | 8.03 | 3.70 | 3.70 | 8.0343 | 7.8458 | 8.0343 | 0.9765 | 1.0000 |
PSZ-AC:3 | 1.22 | 1.22 | 0.79 | 0.79 | 1.2189 | 1.2189 | 1.2189 | 1.0000 | 1.0000 |
PSZ-AC:4 | 0.98 | 0.98 | 0.79 | 0.79 | 0.9790 | 0.9790 | 0.9790 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 131506.172 | 131506.172 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | 131506.17 | 131506.17 | 5.869727 | 20.83 | 12.42 | 0.00594214 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 20.96 | 0.00595607 | 37.1094 | 131363.37 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 33675.790 | 0.000 | 1.766370 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 33675.79 | 27096.15 | 1.766370 | 24.78 | 17.32 | 0.00984550 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01270324 | 21.10 | 13.1097 | 23.88 | 0.01006814 | 52.1685 | 19569.39 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 52518.295 | 52518.295 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 52518.30 | 52518.30 | 1.766367 | 13.18 | 10.03 | 0.00669514 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 13.1098 | 21.11 | 0.00779641 | 47.9912 | 30213.56 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 163714.620 | 0.000 | 8.034260 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 163714.62 | 128120.20 | 8.034260 | 25.48 | 17.76 | 0.01011560 | 12.80 | 11.72 | 0.00850000 | 30.10 | 0.01270324 | 21.10 | 23.5269 | 23.89 | 0.00968838 | 50.2285 | 80499.74 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 291316.875 | 291316.875 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 291316.88 | 291316.88 | 8.034260 | -6.49 | -6.49 | 0.00387774 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 23.5269 | 21.11 | 0.00773689 | 47.6288 | 70784.10 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 22163.770 | 0.000 | 1.218930 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 22163.77 | 18745.27 | 1.218930 | 24.77 | 17.04 | 0.00950925 | 12.80 | 11.72 | 0.00850000 | 29.89 | 0.01270324 | 21.04 | 14.6120 | 23.89 | 0.00896163 | 46.5069 | 13252.33 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 38019.411 | 38019.411 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 38019.41 | 38019.41 | 1.218931 | 8.82 | 7.44 | 0.00612104 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 14.6120 | 21.11 | 0.00785383 | 48.3398 | 14836.96 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 18587.770 | 0.000 | 0.979030 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 18587.77 | 15241.21 | 0.979030 | 25.00 | 17.30 | 0.00973564 | 12.80 | 11.72 | 0.00850000 | 30.00 | 0.01270324 | 21.07 | 18.1926 | 23.89 | 0.00907330 | 47.0781 | 10632.96 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 32716.826 | 32716.826 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 32716.83 | 32716.83 | 0.979026 | 8.82 | 7.44 | 0.00612095 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 18.1926 | 21.11 | 0.00785382 | 48.3397 | 14836.29 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 131506.172 | 131506.172 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 5.869727 | 6.77322390 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 13:10:00 | 131506.17 | 131506.17 | 1.0000 | 6.77322390 | 5.869727 | 20.83 | 12.42 | 0.00594214 | 36022.0 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 131506.17 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 20.98 | 0.00595607 | 20.96 | 0.00595607 | 37.1094 | 131363.37 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 33675.790 | 0.000 | 1.766370 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.1423 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 33675.79 | 27096.15 | 1.0000 | 2.03825825 | 1.766370 | 24.78 | 17.32 | 0.00984550 | 49979.9 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 33675.79 | 30.10 | 0.01270324 | 21.10 | 0.23156651 | 13.1097 | 23.89 | 0.00936407 | 23.88 | 0.01006814 | 52.1685 | 19569.39 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 52518.295 | 52518.295 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.766367 | 2.03825449 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 52518.30 | 52518.30 | 1.0000 | 2.03825449 | 1.766367 | 13.18 | 10.03 | 0.00669514 | 30156.3 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 52518.30 | -32.70 | 0.00018338 | -32.70 | 0.23156651 | 13.1098 | 20.94 | 0.00779641 | 21.11 | 0.00779641 | 47.9912 | 30213.56 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 163714.620 | 0.000 | 8.034260 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.6444 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 163714.62 | 128120.20 | 1.0000 | 9.27093232 | 8.034260 | 25.48 | 17.76 | 0.01011560 | 51376.0 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 163714.62 | 30.10 | 0.01270324 | 21.10 | 1.89021192 | 23.5269 | 23.89 | 0.00922745 | 23.89 | 0.00968838 | 50.2285 | 80499.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 291316.875 | 291316.875 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 8.034260 | 9.27093275 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 291316.88 | 291316.88 | 1.0000 | 9.27093275 | 8.034260 | -6.49 | -6.49 | 0.00387774 | 3129.7 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 291316.88 | -32.70 | 0.00018338 | -32.70 | 1.89021192 | 23.5269 | 20.89 | 0.00773689 | 21.11 | 0.00773689 | 47.6288 | 70784.10 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 22163.770 | 0.000 | 1.218930 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.5172 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 22163.77 | 18745.27 | 1.0000 | 1.40655363 | 1.218930 | 24.77 | 17.04 | 0.00950925 | 49105.9 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 22163.77 | 29.89 | 0.01270324 | 21.04 | 0.17811053 | 14.6120 | 23.89 | 0.00896208 | 23.89 | 0.00896163 | 46.5069 | 13252.33 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 38019.411 | 38019.411 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.218931 | 1.40655473 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 38019.41 | 38019.41 | 1.0000 | 1.40655473 | 1.218931 | 8.82 | 7.44 | 0.00612104 | 24272.4 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 38019.41 | -32.70 | 0.00018338 | -32.70 | 0.17811053 | 14.6120 | 20.94 | 0.00785383 | 21.11 | 0.00785383 | 48.3398 | 14836.96 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 18587.770 | 0.000 | 0.979030 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.9381 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:50:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 18587.77 | 15241.21 | 1.0000 | 1.12972705 | 0.979030 | 25.00 | 17.30 | 0.00973564 | 49923.1 | 12.80 | 11.72 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18587.77 | 30.00 | 0.01270324 | 21.07 | 0.17811053 | 18.1926 | 23.89 | 0.00907410 | 23.89 | 0.00907330 | 47.0781 | 10632.96 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 32716.826 | 32716.826 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.979026 | 1.12972200 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 32716.83 | 32716.83 | 1.0000 | 1.12972200 | 0.979026 | 8.82 | 7.44 | 0.00612095 | 24271.6 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 32716.83 | -32.70 | 0.00018338 | -32.70 | 0.17811053 | 18.1926 | 20.94 | 0.00785382 | 21.11 | 0.00785382 | 48.3397 | 14836.29 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2998.00 | 3655.67 | 2347.83 |
CORE_RETAIL | 2839.50 | 3111.00 | 1636.50 |
POINT_OF_SALE | 2952.00 | 2989.50 | 1593.33 |
FRONT_RETAIL | 3050.17 | 3314.33 | 1922.67 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 3725.50 | 3683.33 | 2367.33 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 119.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 23.17 | 3.33 | 0.00 | 0.00 |
POINT_OF_SALE | 89.00 | 1.50 | 0.00 | 0.00 |
FRONT_RETAIL | 117.00 | 0.17 | 0.00 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 190.83 | 4.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.47 | 61.34 | 2317.33 | 0.365 | 0.054 | 0.000 | 0.000 |
CORE_RETAIL | 128.37 | 258.43 | 9762.95 | 0.707 | 0.011 | 0.000 | 0.000 |
POINT_OF_SALE | 12.10 | 24.35 | 919.94 | 0.707 | 0.059 | 0.000 | 0.000 |
FRONT_RETAIL | 12.10 | 24.35 | 919.94 | 0.707 | 0.059 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.47 | 61.34 | 2317.33 | 0.352 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.37 | 258.43 | 9762.95 | 0.682 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.10 | 24.35 | 919.94 | 0.682 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.10 | 24.35 | 919.94 | 0.682 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 11 | 11 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1382.17 | 3648.35 | 09-APR-05:50 | 120284.19 | 29-JUN-16:00 |
Electricity:Building | 670.39 | 3648.35 | 01-JAN-00:10 | 44155.79 | 02-JAN-09:10 |
Electricity:Zone:BACK_SPACE | 90.98 | 618.37 | 01-JAN-00:10 | 5639.90 | 02-JAN-09:10 |
InteriorLights:Electricity | 475.23 | 1853.18 | 01-JAN-00:10 | 33384.75 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:BACK_SPACE | 40.98 | 158.51 | 01-JAN-00:10 | 2880.76 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 475.23 | 1853.18 | 01-JAN-00:10 | 33384.75 | 02-JAN-09:10 |
Electricity:Zone:CORE_RETAIL | 447.93 | 2194.53 | 01-JAN-00:10 | 30196.29 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 363.63 | 1419.09 | 01-JAN-00:10 | 25543.68 | 02-JAN-09:10 |
Electricity:Zone:POINT_OF_SALE | 87.19 | 620.53 | 01-JAN-00:10 | 5327.81 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 34.26 | 133.72 | 01-JAN-00:10 | 2406.93 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 42.21 | 206.79 | 01-JAN-00:10 | 2845.33 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 34.26 | 133.72 | 01-JAN-00:10 | 2406.93 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 2.08 | 8.14 | 01-JAN-00:10 | 146.46 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 2.08 | 8.14 | 01-JAN-00:10 | 146.46 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1382.17 | 3648.35 | 07-MAY-19:10 | 120284.19 | 29-JUN-16:00 |
ElectricityPurchased:Plant | 1382.17 | 3648.35 | 07-MAY-19:10 | 120284.19 | 29-JUN-16:00 |
Cogeneration:ElectricityPurchased | 1382.17 | 3648.35 | 07-MAY-19:10 | 120284.19 | 29-JUN-16:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1382.17 | 3648.35 | 07-MAY-19:10 | 120284.19 | 29-JUN-16:00 |
ElectricityNet:Plant | 1382.17 | 3648.35 | 07-MAY-19:10 | 120284.19 | 29-JUN-16:00 |
Cogeneration:ElectricityNet | 1382.17 | 3648.35 | 07-MAY-19:10 | 120284.19 | 29-JUN-16:00 |
Electricity:HVAC | 638.97 | 0.00 | 02-JAN-21:10 | 76128.40 | 29-JUN-16:00 |
Fans:Electricity | 504.52 | 0.00 | 02-JAN-21:10 | 30315.37 | 01-JAN-08:10 |
General:Fans:Electricity | 504.52 | 0.00 | 02-JAN-21:10 | 30315.37 | 01-JAN-08:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 134.45 | 0.00 | 01-JAN-00:10 | 56833.44 | 29-JUN-16:00 |
ExteriorLights:Electricity | 72.81 | 0.00 | 01-JAN-08:20 | 4644.36 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 72.81 | 0.00 | 01-JAN-08:20 | 4644.36 | 01-JAN-00:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 1174.04 | 1862.00 | 05-JAN-05:40 | 429063.07 | 09-JAN-05:10 |
Gas:Plant | 100.74 | 1862.00 | 02-JAN-05:30 | 6349.07 | 24-FEB-12:40 |
WaterSystems:Gas | 100.74 | 1862.00 | 02-JAN-05:30 | 6349.07 | 24-FEB-12:40 |
Water Heater:WaterSystems:Gas | 100.74 | 1862.00 | 02-JAN-05:30 | 6349.07 | 24-FEB-12:40 |
Gas:HVAC | 1073.29 | 0.00 | 01-JAN-00:40 | 427201.07 | 09-JAN-05:10 |
Heating:Gas | 1073.29 | 0.00 | 01-JAN-00:40 | 427201.07 | 09-JAN-05:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 03-NOV-11:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 2198.31 | 0.00 | 02-JAN-21:10 | 575078.33 | 09-JAN-05:10 |
EnergyTransfer:Building | 888.80 | 0.00 | 02-JAN-21:10 | 238293.71 | 01-JAN-07:10 |
EnergyTransfer:Zone:BACK_SPACE | 119.69 | 0.00 | 01-JAN-00:40 | 45710.52 | 03-JAN-05:20 |
Heating:EnergyTransfer | 448.93 | 0.00 | 02-JAN-21:10 | 238293.71 | 01-JAN-07:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 81.71 | 0.00 | 01-JAN-00:40 | 45710.52 | 03-JAN-05:20 |
Cooling:EnergyTransfer | 439.86 | 0.00 | 01-JAN-00:10 | 83543.69 | 30-JUN-14:40 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 37.98 | 0.00 | 01-JAN-00:10 | 12459.63 | 30-JUN-15:00 |
EnergyTransfer:Zone:CORE_RETAIL | 375.26 | 0.00 | 01-JAN-00:10 | 150072.16 | 25-DEC-07:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 58.77 | 0.00 | 01-JAN-00:10 | 150072.16 | 25-DEC-07:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 316.48 | 0.00 | 01-JAN-00:10 | 53138.96 | 30-JUN-14:40 |
EnergyTransfer:Zone:POINT_OF_SALE | 72.51 | 0.00 | 01-JAN-00:40 | 24343.49 | 12-JAN-05:20 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 18.87 | 0.00 | 01-JAN-00:40 | 24343.49 | 12-JAN-05:20 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 53.64 | 0.00 | 01-JAN-00:10 | 11609.88 | 01-SEP-13:30 |
EnergyTransfer:Zone:FRONT_RETAIL | 60.65 | 0.00 | 01-JAN-00:40 | 24336.89 | 13-FEB-05:20 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 28.90 | 0.00 | 01-JAN-00:40 | 24336.89 | 13-FEB-05:20 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 31.75 | 0.00 | 01-JAN-00:10 | 9434.52 | 01-SEP-13:30 |
EnergyTransfer:Zone:FRONT_ENTRY | 260.69 | 0.00 | 01-JAN-20:10 | 99722.24 | 05-JAN-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 260.69 | 0.00 | 01-JAN-20:10 | 99722.24 | 05-JAN-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 1309.51 | 0.00 | 01-JAN-00:40 | 341760.85 | 09-JAN-05:10 |
HeatingCoils:EnergyTransfer | 858.63 | 0.00 | 01-JAN-00:40 | 341760.85 | 09-JAN-05:10 |
CoolingCoils:EnergyTransfer | 450.87 | 0.00 | 01-JAN-00:10 | 186015.60 | 30-JUN-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 81.707 | -37.983 | 0.000 | 0.000 | 40.125 | 40.985 | 49.992 | 0.000 | 0.000 | 0.166 | 0.000 | 0.000 | 0.000 | 0.000 | -42.826 | -132.165 |
CORE_RETAIL | 0.000 | 0.000 | 58.772 | -316.484 | 0.000 | 0.000 | 168.018 | 363.635 | 84.299 | 6.160 | 0.000 | 0.133 | 0.010 | 0.000 | -10.003 | 0.000 | -37.722 | -316.809 |
POINT_OF_SALE | 0.000 | 0.000 | 18.866 | -53.645 | 0.000 | 0.000 | 15.662 | 34.265 | 52.922 | 38.169 | 0.000 | 0.069 | 0.002 | 0.000 | -29.900 | 0.000 | -19.192 | -57.216 |
FRONT_RETAIL | 0.000 | 0.000 | 28.901 | -31.753 | 0.000 | 0.000 | 15.901 | 34.265 | 7.943 | 38.246 | 0.000 | 0.070 | 0.001 | 0.000 | -29.367 | 0.000 | -18.749 | -45.457 |
FRONT_ENTRY | 260.690 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 2.085 | 0.000 | 7.665 | 0.000 | 0.034 | 0.000 | 0.000 | -6.147 | 0.000 | -259.856 | -4.469 |
Total Facility | 260.690 | 0.000 | 188.245 | -439.864 | 0.000 | 0.000 | 239.706 | 475.233 | 195.156 | 90.240 | 0.000 | 0.473 | 0.014 | 0.000 | -75.417 | 0.000 | -378.345 | -556.116 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 25-JUL-04:02 | 0.00 | 0.00 | 0.00 | -25308.14 | 0.00 | 0.00 | 0.00 | 158.51 | 613.14 | 0.00 | 0.00 | 0.00 | 24709.28 | 0.00 | -0.00 | 0.00 | -172.80 | 0.00 |
CORE_RETAIL | 19-MAY-04:03 | 0.00 | 0.00 | 0.00 | -145753.59 | 0.00 | 0.00 | 0.00 | 1419.09 | 1033.91 | 0.00 | 0.00 | 0.00 | 143877.77 | 0.00 | -309.60 | 0.00 | -267.59 | 0.00 |
POINT_OF_SALE | 25-AUG-04:02 | 0.00 | 0.00 | 0.00 | -19303.80 | 0.00 | 0.00 | 0.00 | 133.72 | 649.09 | 0.00 | 0.00 | 0.00 | 19847.52 | 0.00 | -1326.53 | 0.00 | 0.00 | 0.00 |
FRONT_RETAIL | 26-AUG-04:02 | 0.00 | 0.00 | 0.00 | -14764.11 | 0.00 | 0.00 | 0.00 | 133.72 | 73.07 | 0.00 | 0.00 | 0.00 | 15613.16 | 0.00 | -962.39 | 0.00 | -93.46 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 26-AUG-04:02 | 0.00 | 0.00 | 0.00 | -186164.76 | 0.00 | 0.00 | 0.00 | 1853.18 | 1795.17 | 0.00 | 0.00 | 0.00 | 185564.22 | 0.00 | -2453.58 | 0.00 | -594.22 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 31-OCT-04:01 | 0.00 | 0.00 | 51056.78 | 0.00 | 0.00 | 0.00 | 0.00 | 158.51 | 613.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -3353.75 | -48474.69 |
CORE_RETAIL | 20-NOV-05:01 | 0.00 | 0.00 | 266523.61 | 0.00 | 0.00 | 0.00 | 0.00 | 1419.09 | 1033.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -305.93 | 0.00 | -2956.05 | -265714.64 |
POINT_OF_SALE | 31-OCT-04:01 | 0.00 | 0.00 | 36088.52 | 0.00 | 0.00 | 0.00 | 0.00 | 133.72 | 649.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -709.61 | 0.00 | -1647.49 | -34514.23 |
FRONT_RETAIL | 31-OCT-04:01 | 0.00 | 0.00 | 31141.27 | 0.00 | 0.00 | 0.00 | 0.00 | 133.72 | 97.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -665.64 | 0.00 | -1493.35 | -29213.42 |
FRONT_ENTRY | 05-JAN-18:00 | 99722.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 146.46 | 0.00 | 0.00 | 0.00 | 0.00 | 124.98 | 0.00 | -727.34 | 0.00 | -99266.29 | 0.00 |
Total Facility | 20-NOV-05:01 | 3594.28 | 0.00 | 382057.17 | 0.00 | 0.00 | 0.00 | 0.00 | 1853.18 | 2393.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2492.24 | 0.00 | -8802.98 | -378602.98 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.7250 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.7664 | 0.1311 | 1.0000 | 0.2316 | 0.1311 | ||
PSZ-AC:2 | 7.8458 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 8.0343 | 0.2353 | 1.0000 | 1.8902 | 0.2353 | ||
PSZ-AC:3 | 1.2189 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.2189 | 0.1461 | 1.0000 | 0.1781 | 0.1461 | ||
PSZ-AC:4 | 0.9790 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.9790 | 0.1819 | 1.0000 | 0.1781 | 0.1819 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.7250 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.7250 | 1.0000 | 1.0000 | 0.2316 | 0.1342 | ||
PSZ-AC:2 | 7.8458 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.8458 | 1.0000 | 1.0000 | 1.8902 | 0.2409 | ||
PSZ-AC:3 | 1.2189 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.2189 | 1.0000 | 1.0000 | 0.1781 | 0.1461 | ||
PSZ-AC:4 | 0.9790 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.9790 | 1.0000 | 1.0000 | 0.1781 | 0.1819 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.7250 | 1.7250 | 1.7250 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.8458 | 7.8458 | 7.8458 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.2189 | 1.2189 | 1.2189 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.9790 | 0.9790 | 0.9790 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.7250 | 1.7664 | 1.7250 | 1.7250 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.8458 | 8.0343 | 7.8458 | 7.8458 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.2189 | 1.2189 | 1.2189 | 1.2189 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.9790 | 0.9790 | 0.9790 | 0.9790 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.7250 | 1.7250 | 1.7250 | 0.2316 | 0.1447 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.8458 | 7.8458 | 7.8458 | 1.8902 | 0.5109 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.2189 | 1.2189 | 1.2189 | 0.1781 | 0.2259 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.9790 | 0.9790 | 0.9790 | 0.1781 | 0.2259 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.7250 | 1.7250 | 1.7250 | 1.7250 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.8458 | 7.8458 | 7.8458 | 7.8458 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.2189 | 1.2189 | 1.2189 | 1.2189 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.9790 | 0.9790 | 0.9790 | 0.9790 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:11
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 1073.29 | 427201.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 134.45 | 56833.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 475.23 | 33384.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 72.81 | 4644.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 504.52 | 30315.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 100.74 | 6349.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 1382.17 |
Natural Gas | 0.00 | 1174.04 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 2556.21 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 207.16 |
Space Heating | 0.00 |
Space Cooling | 58.61 |
Fans (All) | 219.93 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 602.52 |
Subtotal | 602.52 |
Natural Gas [MJ/m2] | |
Space Heating | 467.87 |
Service Water Heating | 43.92 |
Miscellaneous (All) | 511.79 |
Subtotal | 511.79 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 18.59 |
Space Heating | 41.99 |
Space Cooling | 5.26 |
Fans (All) | 19.74 |
Service Water Heating | 3.94 |
Receptacle Equipment | 7.63 |
Miscellaneous | 2.85 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3641. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2505. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_NO_OPTIMUM | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.287328E+12 |
February | 0.000 | 0.191376E+12 |
March | 0.000 | 0.147501E+12 |
April | 0.000 | 0.468224E+11 |
May | 0.000 | 0.383139E+10 |
June | 0.000 | 0.944450E+08 |
July | 0.000 | 0.205957E+08 |
August | 0.000 | 0.136482E+09 |
September | 0.000 | 0.153136E+10 |
October | 0.000 | 0.274269E+11 |
November | 0.000 | 0.105104E+12 |
December | 0.000 | 0.262121E+12 |
Annual Sum or Average | 0.107329E+13 | |
Minimum of Months | 0.000 | 0.205957E+08 |
Maximum of Months | 0.000 | 0.287328E+12 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 631060.52 | 4855.20 | 11-JAN-06:07 | -25.4 | -25.5 | 0.165228E+10 | 1854.44 | 19-JAN-15:39 | -2.8 | -3.5 |
February | 9752446.09 | 3183.10 | 18-FEB-06:06 | -8.3 | -8.7 | 0.150876E+10 | 1854.44 | 04-FEB-11:09 | 0.37 | -1.8 |
March | 0.175737E+09 | 3157.65 | 30-MAR-17:26 | 1.70 | -0.7 | 0.172656E+10 | 1936.90 | 31-MAR-14:00 | 8.30 | 2.61 |
April | 0.868853E+09 | 3570.54 | 14-APR-05:03 | 2.12 | 1.44 | 0.175486E+10 | 2451.26 | 18-APR-14:20 | 16.87 | 9.93 |
May | 0.407117E+10 | 8846.85 | 25-MAY-15:00 | 28.90 | 19.65 | 0.215044E+10 | 2451.26 | 10-MAY-14:00 | 25.00 | 13.59 |
June | 0.703873E+10 | 21319.09 | 29-JUN-04:02 | 22.20 | 19.58 | 0.219364E+10 | 2451.30 | 17-JUN-11:09 | 22.12 | 12.94 |
July | 0.958046E+10 | 25311.14 | 25-JUL-04:02 | 16.02 | 14.98 | 0.218620E+10 | 2451.25 | 08-JUL-10:00 | 13.30 | 12.63 |
August | 0.859974E+10 | 24981.60 | 26-AUG-04:02 | 12.85 | 12.65 | 0.227895E+10 | 2451.25 | 19-AUG-10:09 | 17.57 | 13.14 |
September | 0.485639E+10 | 21035.32 | 01-SEP-04:02 | 16.02 | 16.02 | 0.211505E+10 | 2451.29 | 21-SEP-14:39 | 9.60 | 7.97 |
October | 0.223996E+10 | 4714.83 | 25-OCT-05:07 | -3.5 | -3.8 | 0.186135E+10 | 2451.27 | 21-OCT-12:00 | 19.40 | 11.30 |
November | 0.541178E+09 | 5431.20 | 25-NOV-06:06 | -19.4 | -19.7 | 0.160987E+10 | 2387.60 | 01-NOV-14:00 | 18.30 | 13.43 |
December | 1008981.91 | 5896.78 | 01-DEC-06:05 | -19.5 | -19.7 | 0.165479E+10 | 1854.44 | 06-DEC-15:30 | -6.8 | -6.9 |
Annual Sum or Average | 0.379836E+11 | 0.226927E+11 | ||||||||
Minimum of Months | 631060.52 | 3157.65 | -25.4 | -25.5 | 0.150876E+10 | 1854.44 | -6.8 | -6.9 | ||
Maximum of Months | 0.958046E+10 | 25311.14 | 28.90 | 19.65 | 0.227895E+10 | 2451.30 | 25.00 | 13.59 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.528190E+10 | 50975.01 | 17-JAN-19:03 | -10.3 | -10.6 | 0.696114E+10 | 7812.80 | 14-JAN-11:09 | -17.5 | -17.8 |
February | 0.888502E+10 | 22369.90 | 08-FEB-16:20 | 4.03 | -0.8 | 0.636108E+10 | 8196.45 | 04-FEB-16:19 | 7.60 | 2.44 |
March | 0.160667E+11 | 50692.13 | 07-MAR-20:42 | -9.9 | -10.5 | 0.731790E+10 | 9261.61 | 31-MAR-14:00 | 8.30 | 2.61 |
April | 0.229989E+11 | 43807.92 | 27-APR-05:02 | -4.2 | -5.0 | 0.780386E+10 | 10327.14 | 22-APR-10:50 | 14.72 | 5.45 |
May | 0.359497E+11 | 145770.14 | 19-MAY-04:03 | 14.12 | 9.54 | 0.923611E+10 | 10327.31 | 18-MAY-14:20 | 28.63 | 16.68 |
June | 0.440995E+11 | 131647.13 | 22-JUN-04:03 | 12.98 | 12.26 | 0.926631E+10 | 10327.27 | 15-JUN-14:00 | 21.70 | 13.19 |
July | 0.506300E+11 | 139135.82 | 01-JUL-04:02 | 9.90 | 9.57 | 0.921374E+10 | 10327.11 | 08-JUL-10:30 | 13.30 | 12.49 |
August | 0.480372E+11 | 140096.96 | 25-AUG-04:02 | 8.72 | 8.66 | 0.960589E+10 | 10327.11 | 19-AUG-10:09 | 17.57 | 13.14 |
September | 0.355351E+11 | 132132.90 | 02-SEP-04:02 | 14.82 | 11.36 | 0.898153E+10 | 10327.24 | 21-SEP-14:50 | 9.50 | 7.96 |
October | 0.266818E+11 | 42189.98 | 06-OCT-05:02 | -5.3 | -5.8 | 0.802250E+10 | 10327.19 | 21-OCT-12:09 | 18.07 | 11.00 |
November | 0.156066E+11 | 39262.57 | 17-NOV-06:03 | -4.3 | -5.2 | 0.689120E+10 | 10327.04 | 01-NOV-14:09 | 17.88 | 13.28 |
December | 0.671134E+10 | 17322.01 | 06-DEC-15:20 | -6.8 | -6.9 | 0.697167E+10 | 7812.78 | 16-DEC-11:09 | -10.9 | -11.2 |
Annual Sum or Average | 0.316484E+12 | 0.966329E+11 | ||||||||
Minimum of Months | 0.528190E+10 | 17322.01 | -10.3 | -10.6 | 0.636108E+10 | 7812.78 | -17.5 | -17.8 | ||
Maximum of Months | 0.506300E+11 | 145770.14 | 14.82 | 12.26 | 0.960589E+10 | 10327.31 | 28.63 | 16.68 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.101148E+10 | 8666.51 | 01-JAN-08:04 | -26.7 | -26.9 | 0.655935E+09 | 736.33 | 27-JAN-15:09 | -14.4 | -15.5 |
February | 0.166416E+10 | 8020.37 | 13-FEB-06:04 | -24.0 | -24.3 | 0.621493E+09 | 973.09 | 04-FEB-16:10 | 7.70 | 2.50 |
March | 0.232802E+10 | 5102.77 | 17-MAR-05:04 | -8.1 | -8.9 | 0.723912E+09 | 973.09 | 29-MAR-14:09 | 3.98 | 0.93 |
April | 0.335493E+10 | 7183.36 | 22-APR-13:40 | 17.23 | 7.20 | 0.763368E+09 | 973.10 | 22-APR-10:50 | 14.72 | 5.45 |
May | 0.579792E+10 | 16842.00 | 26-MAY-04:02 | 19.40 | 15.70 | 0.874027E+09 | 973.18 | 24-MAY-14:09 | 27.22 | 17.66 |
June | 0.709723E+10 | 16563.78 | 28-JUN-04:02 | 15.40 | 14.76 | 0.872705E+09 | 973.19 | 21-JUN-14:30 | 24.40 | 16.57 |
July | 0.881749E+10 | 18664.42 | 01-JUL-04:02 | 9.90 | 9.57 | 0.868168E+09 | 973.17 | 31-JUL-14:20 | 20.40 | 14.42 |
August | 0.896218E+10 | 19307.13 | 25-AUG-04:02 | 8.72 | 8.66 | 0.905132E+09 | 973.19 | 25-AUG-14:00 | 28.30 | 19.19 |
September | 0.696174E+10 | 18902.06 | 02-SEP-04:02 | 14.82 | 11.36 | 0.849565E+09 | 973.15 | 01-SEP-14:09 | 25.68 | 18.04 |
October | 0.450631E+10 | 9912.88 | 20-OCT-14:10 | 18.90 | 10.05 | 0.797475E+09 | 973.12 | 07-OCT-10:30 | 11.95 | 11.31 |
November | 0.228092E+10 | 5478.31 | 17-NOV-13:30 | 10.30 | 3.30 | 0.686275E+09 | 973.10 | 14-NOV-15:09 | 10.73 | 6.42 |
December | 0.862362E+09 | 6343.54 | 16-DEC-06:04 | -15.5 | -15.8 | 0.657236E+09 | 753.66 | 28-DEC-15:09 | -1.8 | -3.6 |
Annual Sum or Average | 0.536447E+11 | 0.927529E+10 | ||||||||
Minimum of Months | 0.862362E+09 | 5102.77 | -26.7 | -26.9 | 0.621493E+09 | 736.33 | -14.4 | -15.5 | ||
Maximum of Months | 0.896218E+10 | 19307.13 | 19.40 | 15.70 | 0.905132E+09 | 973.19 | 28.30 | 19.19 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.298329E+09 | 7289.41 | 13-JAN-16:32 | -21.8 | -22.3 | 0.655928E+09 | 736.18 | 07-JAN-16:49 | -18.6 | -19.0 |
February | 0.689001E+09 | 5183.56 | 18-FEB-16:23 | -11.4 | -12.7 | 0.605163E+09 | 924.97 | 28-FEB-15:50 | 6.10 | 1.53 |
March | 0.102812E+10 | 6327.04 | 13-MAR-05:05 | -13.3 | -14.5 | 0.695687E+09 | 972.59 | 31-MAR-14:00 | 8.30 | 2.61 |
April | 0.175959E+10 | 4819.31 | 22-APR-13:40 | 17.23 | 7.20 | 0.718908E+09 | 973.10 | 22-APR-10:50 | 14.72 | 5.45 |
May | 0.332660E+10 | 9415.42 | 26-MAY-04:02 | 19.40 | 15.70 | 0.849400E+09 | 973.15 | 17-MAY-14:09 | 26.20 | 16.18 |
June | 0.437464E+10 | 11776.91 | 28-JUN-04:02 | 15.40 | 14.76 | 0.867828E+09 | 973.16 | 07-JUN-14:09 | 22.20 | 14.32 |
July | 0.591438E+10 | 14057.27 | 25-JUL-04:02 | 16.02 | 14.98 | 0.867191E+09 | 973.15 | 07-JUL-14:00 | 22.20 | 14.39 |
August | 0.596640E+10 | 14766.83 | 26-AUG-04:02 | 12.85 | 12.65 | 0.903382E+09 | 973.14 | 05-AUG-15:00 | 22.80 | 14.57 |
September | 0.448862E+10 | 12905.22 | 02-SEP-04:02 | 14.82 | 11.36 | 0.828618E+09 | 973.15 | 30-SEP-15:00 | 21.10 | 13.66 |
October | 0.271966E+10 | 7499.45 | 20-OCT-14:10 | 18.90 | 10.05 | 0.738465E+09 | 973.13 | 18-OCT-14:09 | 16.78 | 11.26 |
November | 0.978398E+09 | 4003.74 | 10-NOV-12:50 | -2.9 | -5.2 | 0.648872E+09 | 973.10 | 01-NOV-14:00 | 18.30 | 13.43 |
December | 0.208965E+09 | 7587.74 | 10-DEC-12:42 | -23.4 | -23.9 | 0.656923E+09 | 736.18 | 23-DEC-12:30 | -15.5 | -16.1 |
Annual Sum or Average | 0.317527E+11 | 0.903637E+10 | ||||||||
Minimum of Months | 0.208965E+09 | 4003.74 | -23.4 | -23.9 | 0.605163E+09 | 736.18 | -18.6 | -19.0 | ||
Maximum of Months | 0.596640E+10 | 14766.83 | 19.40 | 15.70 | 0.903382E+09 | 973.16 | 26.20 | 16.18 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | -21.9 | -22.1 | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 |
February | 0.00 | 0.00 | 01-FEB-00:02 | -23.1 | -23.4 | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.4 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.2 | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.2 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.37 | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.37 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.3 | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.3 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.56 | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.56 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.50 | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.50 |
December | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -23.1 | -23.4 | 0.00 | 0.00 | -23.1 | -23.4 | ||
Maximum of Months | 0.00 | 0.00 | 19.75 | 18.15 | 0.00 | 0.00 | 19.75 | 18.15 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.217548E+11 | 48711.23 | 16-JAN-07:01 | -1.6 |
February | 0.157015E+11 | 50652.89 | 21-FEB-05:32 | 2.60 |
March | 0.116205E+11 | 49343.65 | 28-MAR-04:01 | 2.12 |
April | 0.436706E+10 | 50399.92 | 18-APR-04:02 | 11.70 |
May | 0.346028E+09 | 48839.05 | 09-MAY-04:01 | 4.63 |
June | 11700997.00 | 1205.57 | 29-JUN-05:10 | 22.30 |
July | 1962698.25 | 1770.42 | 30-JUL-07:04 | 21.65 |
August | 2435310.27 | 630.63 | 09-AUG-05:10 | 18.40 |
September | 3231336.67 | 2379.69 | 28-SEP-05:05 | 6.70 |
October | 0.142124E+10 | 51056.44 | 31-OCT-04:01 | 10.00 |
November | 0.732466E+10 | 50898.84 | 01-NOV-04:01 | 10.60 |
December | 0.191513E+11 | 48940.96 | 30-DEC-05:41 | -5.1 |
Annual Sum or Average | 0.817064E+11 | |||
Minimum of Months | 1962698.25 | 630.63 | -5.1 | |
Maximum of Months | 0.217548E+11 | 51056.44 | 22.30 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.179087E+11 | 256784.18 | 16-JAN-07:01 | -1.6 |
February | 0.110160E+11 | 264553.99 | 21-FEB-05:01 | 2.30 |
March | 0.738582E+10 | 259755.54 | 28-MAR-04:01 | 2.12 |
April | 0.178276E+10 | 259768.63 | 09-APR-06:01 | 2.20 |
May | 70558263.69 | 249151.89 | 01-MAY-04:01 | -2.9 |
June | 2053553.34 | 2225.77 | 18-JUN-07:04 | 17.15 |
July | 2392481.55 | 3169.03 | 03-JUL-05:10 | 17.98 |
August | 504150.88 | 667.61 | 08-AUG-05:10 | 16.70 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
October | 0.475679E+09 | 260317.77 | 10-OCT-04:01 | 2.38 |
November | 0.508038E+10 | 266519.72 | 20-NOV-05:01 | 5.00 |
December | 0.150471E+11 | 256549.26 | 17-DEC-07:01 | -0.9 |
Annual Sum or Average | 0.587720E+11 | |||
Minimum of Months | 0.00 | 0.00 | -2.9 | |
Maximum of Months | 0.179087E+11 | 266519.72 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.542479E+10 | 34439.97 | 16-JAN-07:01 | -1.6 |
February | 0.327982E+10 | 34906.12 | 21-FEB-05:01 | 2.30 |
March | 0.228646E+10 | 34534.62 | 28-MAR-04:01 | 2.12 |
April | 0.820828E+09 | 35008.73 | 08-APR-04:01 | 4.22 |
May | 46856164.60 | 33575.11 | 01-MAY-04:01 | -2.9 |
June | 44454.03 | 81.35 | 23-JUN-05:10 | 17.30 |
July | 279148.76 | 580.44 | 05-JUL-05:10 | 19.60 |
August | 6692.84 | 22.31 | 08-AUG-05:10 | 16.70 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
October | 0.283273E+09 | 36088.08 | 31-OCT-04:01 | 10.00 |
November | 0.168428E+10 | 35915.32 | 01-NOV-04:01 | 10.60 |
December | 0.503892E+10 | 34522.66 | 05-DEC-05:01 | -1.3 |
Annual Sum or Average | 0.188656E+11 | |||
Minimum of Months | 0.00 | 0.00 | -2.9 | |
Maximum of Months | 0.542479E+10 | 36088.08 | 19.75 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.781104E+10 | 29348.56 | 16-JAN-07:01 | -1.6 |
February | 0.488738E+10 | 29930.85 | 21-FEB-05:01 | 2.30 |
March | 0.365156E+10 | 29631.46 | 28-MAR-04:01 | 2.12 |
April | 0.146745E+10 | 30089.39 | 08-APR-04:01 | 4.22 |
May | 0.139065E+09 | 29444.89 | 09-MAY-04:01 | 4.63 |
June | 943561.67 | 264.32 | 01-JUN-08:33 | 19.83 |
July | 96861.18 | 199.52 | 05-JUL-05:10 | 19.60 |
August | 36861.39 | 83.35 | 20-AUG-08:15 | 19.07 |
September | 4922782.01 | 9722.60 | 28-SEP-04:41 | 6.60 |
October | 0.632281E+09 | 31140.88 | 31-OCT-04:01 | 10.00 |
November | 0.281475E+10 | 31027.29 | 01-NOV-04:01 | 10.60 |
December | 0.749114E+10 | 29511.69 | 17-DEC-07:01 | -0.9 |
Annual Sum or Average | 0.289007E+11 | |||
Minimum of Months | 36861.39 | 83.35 | -1.6 | |
Maximum of Months | 0.781104E+10 | 31140.88 | 19.83 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.531847E+11 | 99722.24 | 05-JAN-18:00 | -28.3 |
February | 0.375569E+11 | 86987.53 | 01-FEB-18:00 | -23.3 |
March | 0.343130E+11 | 70104.67 | 15-MAR-11:10 | -15.3 |
April | 0.182985E+11 | 51957.22 | 04-APR-11:03 | -4.9 |
May | 0.645029E+10 | 27170.22 | 08-MAY-11:10 | 6.53 |
June | 0.243269E+10 | 17403.60 | 02-JUN-11:10 | 12.20 |
July | 0.121996E+10 | 14570.69 | 08-JUL-11:03 | 13.30 |
August | 0.198006E+10 | 17725.20 | 17-AUG-12:00 | 10.60 |
September | 0.772837E+10 | 28293.99 | 27-SEP-11:10 | 7.38 |
October | 0.176594E+11 | 43476.22 | 29-OCT-11:02 | 0.68 |
November | 0.288326E+11 | 69358.64 | 25-NOV-17:00 | -15.6 |
December | 0.510330E+11 | 96289.09 | 24-DEC-12:10 | -26.9 |
Annual Sum or Average | 0.260689E+12 | |||
Minimum of Months | 0.121996E+10 | 14570.69 | -28.3 | |
Maximum of Months | 0.531847E+11 | 99722.24 | 13.30 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.343688E+10 | 2880.76 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.312713E+10 | 2880.76 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.356711E+10 | 2880.76 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.336554E+10 | 2880.76 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.350199E+10 | 2880.76 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.344215E+10 | 2880.76 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.342538E+10 | 2880.76 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.356711E+10 | 2880.76 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.336554E+10 | 2880.76 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.343688E+10 | 2880.76 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.332343E+10 | 2880.76 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.342538E+10 | 2880.76 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.409845E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.312713E+10 | 2880.76 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.356711E+10 | 2880.76 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.304941E+11 | 25543.68 | 02-JAN-09:09 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.277456E+11 | 25543.68 | 01-FEB-09:09 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.316486E+11 | 25543.68 | 01-MAR-09:09 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.298606E+11 | 25543.68 | 01-APR-09:09 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.310713E+11 | 25543.68 | 01-MAY-08:09 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.305400E+11 | 25543.68 | 01-JUN-08:09 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.303919E+11 | 25543.68 | 01-JUL-09:09 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.316486E+11 | 25543.68 | 01-AUG-08:09 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.298606E+11 | 25543.68 | 01-SEP-08:09 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.304941E+11 | 25543.68 | 02-OCT-08:09 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.294876E+11 | 25543.68 | 01-NOV-08:09 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.303919E+11 | 25543.68 | 01-DEC-09:09 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.363635E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.277456E+11 | 25543.68 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.316486E+11 | 25543.68 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.287339E+10 | 2406.93 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.261440E+10 | 2406.93 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.298218E+10 | 2406.93 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.281370E+10 | 2406.93 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.292778E+10 | 2406.93 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.287772E+10 | 2406.93 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.286376E+10 | 2406.93 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.298218E+10 | 2406.93 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.281370E+10 | 2406.93 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.287339E+10 | 2406.93 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.277855E+10 | 2406.93 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.286376E+10 | 2406.93 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.342645E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.261440E+10 | 2406.93 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.298218E+10 | 2406.93 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.287339E+10 | 2406.93 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.261440E+10 | 2406.93 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.298218E+10 | 2406.93 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.281370E+10 | 2406.93 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.292778E+10 | 2406.93 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.287772E+10 | 2406.93 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.286376E+10 | 2406.93 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.298218E+10 | 2406.93 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.281370E+10 | 2406.93 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.287339E+10 | 2406.93 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.277855E+10 | 2406.93 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.286376E+10 | 2406.93 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.342645E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.261440E+10 | 2406.93 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.298218E+10 | 2406.93 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.174840E+09 | 146.46 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.159081E+09 | 146.46 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.181459E+09 | 146.46 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.171207E+09 | 146.46 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.178149E+09 | 146.46 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.175103E+09 | 146.46 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.174254E+09 | 146.46 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.181459E+09 | 146.46 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.171207E+09 | 146.46 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.174840E+09 | 146.46 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.169069E+09 | 146.46 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.174254E+09 | 146.46 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.208492E+10 | ||||
Minimum of Months | 0.159081E+09 | 146.46 | 0.00 | 0.00 | |
Maximum of Months | 0.181459E+09 | 146.46 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.343688E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.720028E+10 |
February | 0.479114E+10 | 0.312713E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.621467E+10 |
March | 0.548013E+10 | 0.356711E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.439447E+10 |
April | 0.518069E+10 | 0.336554E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3648100.42 | 0.357220E+10 |
May | 0.536353E+10 | 0.350199E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14961689.51 | 0.178474E+10 |
June | 0.528933E+10 | 0.344215E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 60481825.20 | 0.101367E+10 |
July | 0.525489E+10 | 0.342538E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61912067.81 | 0.693763E+09 |
August | 0.548013E+10 | 0.356711E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23943978.29 | 0.107665E+10 |
September | 0.518069E+10 | 0.336554E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 780136.45 | 0.187342E+10 |
October | 0.524694E+10 | 0.343688E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268038E+10 |
November | 0.504819E+10 | 0.332343E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.487628E+10 |
December | 0.525489E+10 | 0.342538E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.744530E+10 |
Annual Sum or Average | 0.628175E+11 | 0.409845E+11 | 0.499918E+11 | 0.165728E+09 | 0.428258E+11 | ||||
Minimum of Months | 0.479114E+10 | 0.312713E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.693763E+09 |
Maximum of Months | 0.548013E+10 | 0.356711E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61912067.81 | 0.744530E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.304941E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.616909E+10 |
February | 0.201852E+11 | 0.277456E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538595E+10 |
March | 0.230879E+11 | 0.316486E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.386343E+10 |
April | 0.218263E+11 | 0.298606E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2377613.32 | 0.326700E+10 |
May | 0.225967E+11 | 0.310713E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12239100.03 | 0.166590E+10 |
June | 0.222841E+11 | 0.305400E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48007339.61 | 0.949617E+09 |
July | 0.221389E+11 | 0.303919E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50573303.68 | 0.626790E+09 |
August | 0.230879E+11 | 0.316486E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 19590991.40 | 0.970506E+09 |
September | 0.218263E+11 | 0.298606E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 638542.75 | 0.168997E+10 |
October | 0.221054E+11 | 0.304941E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238668E+10 |
November | 0.212681E+11 | 0.294876E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.433186E+10 |
December | 0.221389E+11 | 0.303919E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.641490E+10 |
Annual Sum or Average | 0.264651E+12 | 0.363635E+12 | 0.842987E+11 | 0.133427E+09 | 0.377217E+11 | ||||
Minimum of Months | 0.201852E+11 | 0.277456E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.626790E+09 |
Maximum of Months | 0.230879E+11 | 0.316486E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 50573303.68 | 0.641490E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.287339E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313415E+10 |
February | 0.190200E+10 | 0.261440E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273618E+10 |
March | 0.217552E+10 | 0.298218E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.197640E+10 |
April | 0.205665E+10 | 0.281370E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1156550.10 | 0.165461E+10 |
May | 0.212923E+10 | 0.292778E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6474351.61 | 0.832234E+09 |
June | 0.209978E+10 | 0.287772E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24422004.61 | 0.478275E+09 |
July | 0.208610E+10 | 0.286376E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26511811.74 | 0.329036E+09 |
August | 0.217552E+10 | 0.298218E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10364916.54 | 0.511276E+09 |
September | 0.205665E+10 | 0.281370E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 337730.02 | 0.871932E+09 |
October | 0.208295E+10 | 0.287339E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124583E+10 |
November | 0.200405E+10 | 0.277855E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.218322E+10 |
December | 0.208610E+10 | 0.286376E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323898E+10 |
Annual Sum or Average | 0.249375E+11 | 0.342645E+11 | 0.529224E+11 | 69267364.62 | 0.191921E+11 | ||||
Minimum of Months | 0.190200E+10 | 0.261440E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.329036E+09 |
Maximum of Months | 0.217552E+10 | 0.298218E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26511811.74 | 0.323898E+10 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.287339E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.312195E+10 |
February | 0.190200E+10 | 0.261440E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.271318E+10 |
March | 0.217552E+10 | 0.298218E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193709E+10 |
April | 0.205665E+10 | 0.281370E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1198414.54 | 0.159133E+10 |
May | 0.212923E+10 | 0.292778E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6477333.31 | 0.785552E+09 |
June | 0.209978E+10 | 0.287772E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25156486.82 | 0.443922E+09 |
July | 0.208610E+10 | 0.286376E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 26626550.88 | 0.307832E+09 |
August | 0.217552E+10 | 0.298218E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10367576.06 | 0.483186E+09 |
September | 0.205665E+10 | 0.281370E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 337878.03 | 0.827423E+09 |
October | 0.208295E+10 | 0.287339E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118700E+10 |
November | 0.200405E+10 | 0.277855E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.212913E+10 |
December | 0.208610E+10 | 0.286376E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.322170E+10 |
Annual Sum or Average | 0.249375E+11 | 0.342645E+11 | 0.794328E+10 | 70164239.65 | 0.187493E+11 | ||||
Minimum of Months | 0.190200E+10 | 0.261440E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.307832E+09 |
Maximum of Months | 0.217552E+10 | 0.298218E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 26626550.88 | 0.322170E+10 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.174840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.520635E+11 |
February | 0.00 | 0.159081E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.369369E+11 |
March | 0.00 | 0.181459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.337020E+11 |
April | 0.00 | 0.171207E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182820E+11 |
May | 0.00 | 0.178149E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1348295.66 | 0.688062E+10 |
June | 0.00 | 0.175103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24242186.34 | 0.288578E+10 |
July | 0.00 | 0.174254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7878075.38 | 0.172971E+10 |
August | 0.00 | 0.181459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 525059.92 | 0.271643E+10 |
September | 0.00 | 0.171207E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.848885E+10 |
October | 0.00 | 0.174840E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179340E+11 |
November | 0.00 | 0.169069E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.283560E+11 |
December | 0.00 | 0.174254E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.498806E+11 |
Annual Sum or Average | 0.00 | 0.208492E+10 | 33993617.30 | 0.259856E+12 | |||||
Minimum of Months | 0.00 | 0.159081E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172971E+10 |
Maximum of Months | 0.00 | 0.181459E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24242186.34 | 0.520635E+11 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 2880.76 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 15187.36 | 04-JAN-06:00 |
February | 5888.82 | 01-FEB-15:09 | 2880.76 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 17001.17 | 12-FEB-23:00 |
March | 5888.82 | 01-MAR-15:09 | 2880.76 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 9363.99 | 15-MAR-05:00 |
April | 5888.82 | 01-APR-10:09 | 2880.76 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 545.77 | 23-APR-18:10 | 7163.49 | 01-APR-21:02 |
May | 5888.82 | 01-MAY-14:09 | 2880.76 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 191.09 | 24-MAY-15:00 | 3534.66 | 09-MAY-04:04 |
June | 5888.82 | 01-JUN-14:09 | 2880.76 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 765.32 | 29-JUN-20:03 | 2469.72 | 09-JUN-20:10 |
July | 5888.82 | 01-JUL-10:09 | 2880.76 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 818.37 | 23-JUL-18:03 | 2175.69 | 06-JUL-22:00 |
August | 5888.82 | 01-AUG-14:09 | 2880.76 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 414.83 | 08-AUG-16:00 | 3107.86 | 27-AUG-06:00 |
September | 5888.82 | 01-SEP-14:09 | 2880.76 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 68.50 | 01-SEP-15:00 | 4227.75 | 20-SEP-01:00 |
October | 5888.82 | 02-OCT-14:09 | 2880.76 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 5877.75 | 31-OCT-20:02 |
November | 5888.82 | 01-NOV-14:09 | 2880.76 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 9291.59 | 21-NOV-21:01 |
December | 5888.82 | 01-DEC-15:09 | 2880.76 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 15258.22 | 16-DEC-06:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 2880.76 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2175.69 | |||||
Maximum of Months | 5888.82 | 2880.76 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 818.37 | 17001.17 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 25543.68 | 02-JAN-09:09 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 12538.17 | 04-JAN-06:00 |
February | 24809.68 | 01-FEB-15:09 | 25543.68 | 01-FEB-09:09 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 14727.23 | 12-FEB-22:51 |
March | 24809.68 | 01-MAR-15:09 | 25543.68 | 01-MAR-09:09 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 7664.90 | 15-MAR-04:53 |
April | 24809.68 | 01-APR-10:09 | 25543.68 | 01-APR-09:09 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 359.11 | 23-APR-18:05 | 6005.06 | 02-APR-01:00 |
May | 24809.68 | 01-MAY-14:09 | 25543.68 | 01-MAY-08:09 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 156.42 | 24-MAY-15:00 | 3243.64 | 20-MAY-04:52 |
June | 24809.68 | 01-JUN-14:09 | 25543.68 | 01-JUN-08:09 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 624.71 | 29-JUN-20:03 | 2236.32 | 10-JUN-22:00 |
July | 24809.68 | 01-JUL-10:09 | 25543.68 | 01-JUL-09:09 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 670.28 | 23-JUL-18:03 | 2155.20 | 06-JUL-22:00 |
August | 24809.68 | 01-AUG-14:09 | 25543.68 | 01-AUG-08:09 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 339.54 | 08-AUG-16:00 | 2956.06 | 27-AUG-06:00 |
September | 24809.68 | 01-SEP-14:09 | 25543.68 | 01-SEP-08:09 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 56.07 | 01-SEP-15:00 | 3986.46 | 20-SEP-01:00 |
October | 24809.68 | 02-OCT-14:09 | 25543.68 | 02-OCT-08:09 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 4904.48 | 31-OCT-21:00 |
November | 24809.68 | 01-NOV-14:09 | 25543.68 | 01-NOV-08:09 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 8664.51 | 22-NOV-01:53 |
December | 24809.68 | 01-DEC-15:09 | 25543.68 | 01-DEC-09:09 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 12489.40 | 16-DEC-05:51 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 25543.68 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2155.20 | |||||
Maximum of Months | 24809.68 | 25543.68 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 670.28 | 14727.23 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2406.93 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 6575.11 | 04-JAN-05:51 |
February | 2337.76 | 01-FEB-15:09 | 2406.93 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 7367.20 | 12-FEB-22:51 |
March | 2337.76 | 01-MAR-15:09 | 2406.93 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 4057.72 | 15-MAR-05:00 |
April | 2337.76 | 01-APR-10:09 | 2406.93 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 158.09 | 23-APR-18:05 | 3111.53 | 01-APR-21:02 |
May | 2337.76 | 01-MAY-14:09 | 2406.93 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 82.78 | 24-MAY-15:00 | 1548.88 | 09-MAY-04:04 |
June | 2337.76 | 01-JUN-14:09 | 2406.93 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 320.48 | 29-JUN-20:03 | 1093.39 | 09-JUN-20:10 |
July | 2337.76 | 01-JUL-10:09 | 2406.93 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 338.71 | 23-JUL-18:03 | 1096.21 | 06-JUL-22:00 |
August | 2337.76 | 01-AUG-14:09 | 2406.93 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 179.76 | 08-AUG-16:00 | 1469.39 | 27-AUG-06:00 |
September | 2337.76 | 01-SEP-14:09 | 2406.93 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.67 | 01-SEP-15:00 | 1890.37 | 20-SEP-01:00 |
October | 2337.76 | 02-OCT-14:09 | 2406.93 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2550.26 | 31-OCT-20:02 |
November | 2337.76 | 01-NOV-14:09 | 2406.93 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 4030.26 | 21-NOV-21:01 |
December | 2337.76 | 01-DEC-15:09 | 2406.93 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 6537.50 | 16-DEC-05:51 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2406.93 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1093.39 | |||||
Maximum of Months | 2337.76 | 2406.93 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 338.71 | 7367.20 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2406.93 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 6637.70 | 04-JAN-06:00 |
February | 2337.76 | 01-FEB-15:09 | 2406.93 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 7367.11 | 12-FEB-23:00 |
March | 2337.76 | 01-MAR-15:09 | 2406.93 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 4057.72 | 15-MAR-05:00 |
April | 2337.76 | 01-APR-10:09 | 2406.93 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 174.41 | 23-APR-18:05 | 3105.55 | 01-APR-21:02 |
May | 2337.76 | 01-MAY-14:09 | 2406.93 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 82.81 | 24-MAY-15:00 | 1513.31 | 09-MAY-04:04 |
June | 2337.76 | 01-JUN-14:09 | 2406.93 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 325.32 | 29-JUN-20:03 | 1033.81 | 09-JUN-20:10 |
July | 2337.76 | 01-JUL-10:09 | 2406.93 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 343.49 | 23-JUL-18:03 | 1001.07 | 06-JUL-22:00 |
August | 2337.76 | 01-AUG-14:09 | 2406.93 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 179.76 | 08-AUG-16:00 | 1402.40 | 27-AUG-06:00 |
September | 2337.76 | 01-SEP-14:09 | 2406.93 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.66 | 01-SEP-15:00 | 1802.80 | 20-SEP-01:00 |
October | 2337.76 | 02-OCT-14:09 | 2406.93 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 2544.53 | 31-OCT-20:02 |
November | 2337.76 | 01-NOV-14:09 | 2406.93 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 4024.76 | 23-NOV-08:00 |
December | 2337.76 | 01-DEC-15:09 | 2406.93 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 6533.63 | 16-DEC-05:51 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2406.93 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1001.07 | |||||
Maximum of Months | 2337.76 | 2406.93 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 343.49 | 7367.11 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 146.46 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 99268.59 | 05-JAN-12:10 |
February | 0.00 | 01-FEB-00:10 | 146.46 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 86726.83 | 01-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 146.46 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 70345.01 | 15-MAR-11:10 |
April | 0.00 | 01-APR-00:10 | 146.46 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 54945.72 | 04-APR-11:02 |
May | 0.00 | 01-MAY-00:10 | 146.46 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.77 | 25-MAY-18:00 | 27153.12 | 08-MAY-11:10 |
June | 0.00 | 01-JUN-00:10 | 146.46 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 801.08 | 29-JUN-16:00 | 17864.20 | 02-JUN-11:10 |
July | 0.00 | 01-JUL-00:10 | 146.46 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 488.17 | 15-JUL-13:55 | 15169.09 | 08-JUL-11:03 |
August | 0.00 | 01-AUG-00:10 | 146.46 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.56 | 08-AUG-16:00 | 18218.20 | 17-AUG-12:00 |
September | 0.00 | 01-SEP-00:10 | 146.46 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 28660.62 | 27-SEP-11:10 |
October | 0.00 | 01-OCT-00:10 | 146.46 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 47796.35 | 29-OCT-11:01 |
November | 0.00 | 01-NOV-00:10 | 146.46 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 68964.10 | 25-NOV-17:00 |
December | 0.00 | 01-DEC-00:10 | 146.46 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 96628.38 | 24-DEC-12:10 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 146.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15169.09 | ||||
Maximum of Months | 0.00 | 146.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 801.08 | 99268.59 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4855.20 | 11-JAN-06:07 | 0.00 | 951.06 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3183.10 | 18-FEB-06:06 | 0.00 | 792.55 | 2299.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1603.98 |
March | 3157.65 | 30-MAR-17:26 | 18402.55 | 8002.11 | 13795.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 467.21 |
April | 3570.54 | 14-APR-05:03 | 0.00 | 951.06 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 8846.85 | 25-MAY-15:00 | 5888.82 | 2880.76 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 132.82 | 0.00 |
June | 21319.09 | 29-JUN-04:02 | 0.00 | 951.06 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 278.22 |
July | 25311.14 | 25-JUL-04:02 | 0.00 | 951.06 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 172.80 |
August | 24981.60 | 26-AUG-04:02 | 0.00 | 951.06 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 208.21 |
September | 21035.32 | 01-SEP-04:02 | 0.00 | 792.55 | 3065.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 354.01 |
October | 4714.83 | 25-OCT-05:07 | 0.00 | 475.53 | 1839.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5431.20 | 25-NOV-06:06 | 0.00 | 792.55 | 2299.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1690.28 |
December | 5896.78 | 01-DEC-06:05 | 0.00 | 951.06 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2563.19 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3157.65 | 0.00 | 475.53 | 1839.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 25311.14 | 18402.55 | 8002.11 | 13795.71 | 0.00 | 0.00 | 0.00 | 0.00 | 132.82 | 2563.19 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 50975.01 | 17-JAN-19:03 | 37214.52 | 56763.74 | 14474.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 526.03 |
February | 22369.90 | 08-FEB-16:20 | 21708.47 | 25543.68 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 529.80 |
March | 50692.13 | 07-MAR-20:42 | 46518.15 | 70954.68 | 18093.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.21 |
April | 43807.92 | 27-APR-05:02 | 0.00 | 8514.56 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 796.67 |
May | 145770.14 | 19-MAY-04:03 | 0.00 | 5676.37 | 4135.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 267.59 |
June | 131647.13 | 22-JUN-04:03 | 0.00 | 5676.37 | 4135.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 884.92 |
July | 139135.82 | 01-JUL-04:02 | 0.00 | 7095.47 | 3877.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 699.74 |
August | 140096.96 | 25-AUG-04:02 | 0.00 | 7095.47 | 5169.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 132132.90 | 02-SEP-04:02 | 0.00 | 7095.47 | 3877.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1048.80 |
October | 42189.98 | 06-OCT-05:02 | 0.00 | 8514.56 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 443.00 |
November | 39262.57 | 17-NOV-06:03 | 0.00 | 8514.56 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 440.72 |
December | 17322.01 | 06-DEC-15:20 | 24809.68 | 25543.68 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 692.33 |
Annual Sum or Average | |||||||||||
Minimum of Months | 17322.01 | 0.00 | 5676.37 | 3877.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 145770.14 | 46518.15 | 70954.68 | 18093.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1048.80 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 8666.51 | 01-JAN-08:04 | 0.00 | 936.03 | 3407.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 862.63 |
February | 8020.37 | 13-FEB-06:04 | 0.00 | 936.03 | 4543.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1175.90 |
March | 5102.77 | 17-MAR-05:04 | 0.00 | 668.59 | 3245.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 823.47 |
April | 7183.36 | 22-APR-13:40 | 2337.76 | 2406.93 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.33 |
May | 16842.00 | 26-MAY-04:02 | 0.00 | 668.59 | 3245.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.58 |
June | 16563.78 | 28-JUN-04:02 | 0.00 | 668.59 | 3245.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 18664.42 | 01-JUL-04:02 | 0.00 | 668.59 | 2434.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 356.96 |
August | 19307.13 | 25-AUG-04:02 | 0.00 | 668.59 | 3245.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 18902.06 | 02-SEP-04:02 | 0.00 | 668.59 | 2434.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 548.24 |
October | 9912.88 | 20-OCT-14:10 | 2337.76 | 2406.93 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.94 |
November | 5478.31 | 17-NOV-13:30 | 2045.54 | 2406.93 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 401.85 |
December | 6343.54 | 16-DEC-06:04 | 0.00 | 936.03 | 3407.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1576.27 |
Annual Sum or Average | |||||||||||
Minimum of Months | 5102.77 | 0.00 | 668.59 | 2434.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19307.13 | 2337.76 | 2406.93 | 4543.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1576.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7289.41 | 13-JAN-16:32 | 10227.71 | 12034.63 | 2192.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5183.56 | 18-FEB-16:23 | 9351.05 | 9627.70 | 1753.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 776.62 |
March | 6327.04 | 13-MAR-05:05 | 0.00 | 802.31 | 584.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 497.10 |
April | 4819.31 | 22-APR-13:40 | 2337.76 | 2406.93 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80.33 |
May | 9415.42 | 26-MAY-04:02 | 0.00 | 668.59 | 487.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.61 |
June | 11776.91 | 28-JUN-04:02 | 0.00 | 668.59 | 487.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 14057.27 | 25-JUL-04:02 | 0.00 | 802.31 | 584.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.43 |
August | 14766.83 | 26-AUG-04:02 | 0.00 | 802.31 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.46 |
September | 12905.22 | 02-SEP-04:02 | 0.00 | 668.59 | 365.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 534.32 |
October | 7499.45 | 20-OCT-14:10 | 2337.76 | 2406.93 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.94 |
November | 4003.74 | 10-NOV-12:50 | 2045.54 | 2406.93 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 637.57 |
December | 7587.74 | 10-DEC-12:42 | 5844.40 | 8023.08 | 1948.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1156.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4003.74 | 0.00 | 668.59 | 365.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14766.83 | 10227.71 | 12034.63 | 2192.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1156.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:01 | 0.00 | 56.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 279.11 |
February | 0.00 | 01-FEB-00:02 | 0.00 | 48.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 444.16 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.26 |
April | 0.00 | 01-APR-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.18 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.30 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 70.32 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31.31 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.60 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.65 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.81 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.31 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 260.81 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 8.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.30 | |
Maximum of Months | 0.00 | 0.00 | 56.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 444.16 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.114137E+12 | 79115.51 | 02-JAN-16:30 | 0.296149E+12 | 429063.07 | 09-JAN-05:10 |
February | 0.102025E+12 | 79115.51 | 01-FEB-17:19 | 0.199435E+12 | 360733.98 | 14-FEB-05:10 |
March | 0.112716E+12 | 79115.51 | 02-MAR-17:00 | 0.156490E+12 | 289143.27 | 16-MAR-04:10 |
April | 0.106045E+12 | 88070.81 | 13-APR-14:39 | 0.553516E+11 | 204809.75 | 05-APR-04:10 |
May | 0.116194E+12 | 102892.73 | 25-MAY-14:00 | 0.124541E+11 | 101364.81 | 01-MAY-04:10 |
June | 0.123678E+12 | 120284.19 | 29-JUN-15:00 | 0.828631E+10 | 9429.05 | 02-JUN-11:00 |
July | 0.132389E+12 | 116424.12 | 15-JUL-14:09 | 0.823841E+10 | 6960.70 | 08-JUL-11:00 |
August | 0.130569E+12 | 112570.06 | 08-AUG-14:00 | 0.836115E+10 | 12554.84 | 17-AUG-13:00 |
September | 0.113499E+12 | 100184.11 | 01-SEP-14:20 | 0.946933E+10 | 19257.40 | 27-SEP-11:09 |
October | 0.109623E+12 | 90004.98 | 21-OCT-12:50 | 0.357174E+11 | 125665.17 | 30-OCT-05:10 |
November | 0.107353E+12 | 83284.48 | 01-NOV-16:00 | 0.113294E+12 | 253579.39 | 29-NOV-05:10 |
December | 0.113941E+12 | 79115.51 | 01-DEC-16:19 | 0.270790E+12 | 389006.55 | 26-DEC-05:10 |
Annual Sum or Average | 0.138217E+13 | 0.117404E+13 | ||||
Minimum of Months | 0.102025E+12 | 79115.51 | 0.823841E+10 | 6960.70 | ||
Maximum of Months | 0.132389E+12 | 120284.19 | 0.296149E+12 | 429063.07 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.398525E+11 | 0.798922E+10 | 0.164409E+11 | 0.00 | 0.498538E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.362606E+11 | 0.656248E+10 | 0.149157E+11 | 0.00 | 0.442789E+11 | 0.00 | 0.00 | 7461895.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.413616E+11 | 0.637856E+10 | 0.168545E+11 | 0.00 | 0.481020E+11 | 0.00 | 0.00 | 19453404.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.390247E+11 | 0.528064E+10 | 0.160165E+11 | 0.00 | 0.437115E+11 | 0.00 | 0.00 | 0.201175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.406071E+11 | 0.465365E+10 | 0.166477E+11 | 0.00 | 0.388251E+11 | 0.00 | 0.00 | 0.154605E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.399127E+11 | 0.406846E+10 | 0.162772E+11 | 0.00 | 0.338172E+11 | 0.00 | 0.00 | 0.296020E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.397190E+11 | 0.440842E+10 | 0.163871E+11 | 0.00 | 0.329293E+11 | 0.00 | 0.00 | 0.389452E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.413616E+11 | 0.509672E+10 | 0.168545E+11 | 0.00 | 0.345362E+11 | 0.00 | 0.00 | 0.327197E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.390247E+11 | 0.578223E+10 | 0.160165E+11 | 0.00 | 0.393427E+11 | 0.00 | 0.00 | 0.133333E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.398525E+11 | 0.689966E+10 | 0.164409E+11 | 0.00 | 0.442253E+11 | 0.00 | 0.00 | 0.220482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.385372E+11 | 0.748763E+10 | 0.159174E+11 | 0.00 | 0.452655E+11 | 0.00 | 0.00 | 0.145148E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.397190E+11 | 0.820379E+10 | 0.163871E+11 | 0.00 | 0.496313E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.475233E+12 | 0.728115E+11 | 0.195156E+12 | 0.504519E+12 | 0.00 | 0.134449E+12 | |||||||
Minimum of Months | 0.362606E+11 | 0.406846E+10 | 0.149157E+11 | 0.00 | 0.329293E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.413616E+11 | 0.820379E+10 | 0.168545E+11 | 0.00 | 0.498538E+11 | 0.00 | 0.00 | 0.389452E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.287328E+12 | 0.00 | 0.882132E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.191376E+12 | 0.00 | 0.805944E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.147501E+12 | 0.00 | 0.898917E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.468224E+11 | 0.00 | 0.852921E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.383139E+10 | 0.00 | 0.862268E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 94444986.73 | 0.00 | 0.819186E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 20595685.33 | 0.00 | 0.821781E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.136482E+09 | 0.00 | 0.822467E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.153136E+10 | 0.00 | 0.793797E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.274269E+11 | 0.00 | 0.829059E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.105104E+12 | 0.00 | 0.818911E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.262121E+12 | 0.00 | 0.866941E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.107329E+13 | 0.100743E+12 | |||||
Minimum of Months | 0.00 | 0.00 | 20595685.33 | 0.00 | 0.793797E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.287328E+12 | 0.00 | 0.898917E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 33384.75 | 02-JAN-09:09 | 4644.36 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 30315.37 | 01-JAN-08:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 33384.75 | 01-FEB-09:09 | 4644.36 | 01-FEB-00:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 30315.37 | 01-FEB-11:39 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 33384.75 | 01-MAR-09:09 | 4644.36 | 01-MAR-00:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 30315.37 | 01-MAR-08:20 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 33384.75 | 01-APR-09:09 | 4644.36 | 01-APR-00:10 | 10771.04 | 01-APR-09:09 | 0.00 | 30315.37 | 01-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 33384.75 | 01-MAY-08:09 | 4644.36 | 01-MAY-00:10 | 10771.04 | 01-MAY-08:09 | 0.00 | 30315.37 | 01-MAY-07:49 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 33384.75 | 01-JUN-08:09 | 4644.36 | 01-JUN-00:10 | 10771.04 | 01-JUN-08:09 | 0.00 | 30315.37 | 02-JUN-08:30 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 33384.75 | 01-JUL-09:09 | 4644.36 | 01-JUL-00:10 | 10771.04 | 01-JUL-09:09 | 0.00 | 30315.37 | 01-JUL-12:20 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 33384.75 | 01-AUG-08:09 | 4644.36 | 01-AUG-00:10 | 10771.04 | 01-AUG-08:09 | 0.00 | 30315.37 | 01-AUG-11:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 33384.75 | 01-SEP-08:09 | 4644.36 | 01-SEP-00:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 30315.37 | 02-SEP-13:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 33384.75 | 02-OCT-08:09 | 4644.36 | 01-OCT-00:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 30315.37 | 01-OCT-12:09 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 33384.75 | 01-NOV-08:09 | 4644.36 | 01-NOV-00:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 30315.37 | 01-NOV-11:39 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 33384.75 | 01-DEC-09:09 | 4644.36 | 01-DEC-00:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 30315.37 | 01-DEC-11:30 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 33384.75 | 4644.36 | 10771.04 | 0.00 | 30315.37 | 0.00 | 0.00 | |||||
Maximum of Months | 33384.75 | 4644.36 | 10771.04 | 0.00 | 30315.37 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 526.89 | 28-FEB-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 810.86 | 31-MAR-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 20328.18 | 23-APR-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 39441.98 | 25-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 56833.44 | 29-JUN-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 52973.37 | 15-JUL-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 49119.30 | 08-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 36733.35 | 01-SEP-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 18539.74 | 19-OCT-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 7289.35 | 01-NOV-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 56833.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 79115.51 | 02-JAN-16:30 | 33384.75 | 10771.04 | 4644.36 | 0.00 | 30315.37 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 79115.51 | 01-FEB-17:19 | 33384.75 | 10771.04 | 4644.36 | 0.00 | 30315.37 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 79115.51 | 02-MAR-17:00 | 33384.75 | 10771.04 | 4644.36 | 0.00 | 30315.37 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 88070.81 | 13-APR-14:39 | 33384.75 | 10771.04 | 0.00 | 0.00 | 30315.37 | 0.00 | 0.00 | 13599.66 | 0.00 |
May | 102892.73 | 25-MAY-14:00 | 33384.75 | 10771.04 | 0.00 | 0.00 | 19294.97 | 0.00 | 0.00 | 39441.98 | 0.00 |
June | 120284.19 | 29-JUN-15:00 | 33384.75 | 10771.04 | 0.00 | 0.00 | 19294.97 | 0.00 | 0.00 | 56833.44 | 0.00 |
July | 116424.12 | 15-JUL-14:09 | 33384.75 | 10771.04 | 0.00 | 0.00 | 19294.97 | 0.00 | 0.00 | 52973.37 | 0.00 |
August | 112570.06 | 08-AUG-14:00 | 33384.75 | 10771.04 | 0.00 | 0.00 | 19294.97 | 0.00 | 0.00 | 49119.30 | 0.00 |
September | 100184.11 | 01-SEP-14:20 | 33384.75 | 10771.04 | 0.00 | 0.00 | 19294.97 | 0.00 | 0.00 | 36733.35 | 0.00 |
October | 90004.98 | 21-OCT-12:50 | 33384.75 | 10771.04 | 0.00 | 0.00 | 30315.37 | 0.00 | 0.00 | 15533.83 | 0.00 |
November | 83284.48 | 01-NOV-16:00 | 33384.75 | 10771.04 | 4644.36 | 0.00 | 30315.37 | 0.00 | 0.00 | 4168.96 | 0.00 |
December | 79115.51 | 01-DEC-16:19 | 33384.75 | 10771.04 | 4644.36 | 0.00 | 30315.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 79115.51 | 33384.75 | 10771.04 | 0.00 | 0.00 | 19294.97 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 120284.19 | 33384.75 | 10771.04 | 4644.36 | 0.00 | 30315.37 | 0.00 | 0.00 | 56833.44 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 427201.07 | 09-JAN-05:10 | 0.00 | 6210.38 | 25-JAN-12:00 | 0.00 |
February | 0.00 | 0.00 | 358871.98 | 14-FEB-05:10 | 0.00 | 6349.07 | 24-FEB-12:39 | 0.00 |
March | 0.00 | 0.00 | 287281.27 | 16-MAR-04:10 | 0.00 | 6344.02 | 03-MAR-12:50 | 0.00 |
April | 0.00 | 0.00 | 200721.19 | 04-APR-04:10 | 0.00 | 6146.62 | 03-APR-11:00 | 0.00 |
May | 0.00 | 0.00 | 99502.81 | 01-MAY-04:10 | 0.00 | 5684.70 | 03-MAY-11:30 | 0.00 |
June | 0.00 | 0.00 | 4281.14 | 02-JUN-11:00 | 0.00 | 5150.70 | 01-JUN-11:09 | 0.00 |
July | 0.00 | 0.00 | 1912.71 | 08-JUL-11:00 | 0.00 | 5095.15 | 03-JUL-11:30 | 0.00 |
August | 0.00 | 0.00 | 7765.96 | 17-AUG-13:00 | 0.00 | 5061.74 | 01-AUG-11:20 | 0.00 |
September | 0.00 | 0.00 | 14190.50 | 27-SEP-11:09 | 0.00 | 5069.18 | 29-SEP-11:09 | 0.00 |
October | 0.00 | 0.00 | 123803.17 | 30-OCT-05:10 | 0.00 | 5116.28 | 31-OCT-11:09 | 0.00 |
November | 0.00 | 0.00 | 251717.39 | 29-NOV-05:10 | 0.00 | 5335.49 | 30-NOV-12:20 | 0.00 |
December | 0.00 | 0.00 | 387144.55 | 26-DEC-05:10 | 0.00 | 5851.37 | 28-DEC-12:00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 1912.71 | 0.00 | 5061.74 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 427201.07 | 0.00 | 6349.07 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 34.67 | 16.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 23.17 | 17.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 13.17 | 18.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6.67 | 19.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.50 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 2.17 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 9.17 | 19.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 29.50 | 16.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 119.00 | 17.53 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 34.67 | 20.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 8.00 | 20.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5.17 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 2.17 | 20.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.50 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 24.48 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 24.55 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.00 | 24.52 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 1.33 | 20.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6.50 | 20.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 23.17 | 20.25 | 0.00 | 3.33 | 24.52 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 8.00 | 20.48 | 0.00 | 0.00 | 1.17 | 24.55 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 28.17 | 16.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 16.17 | 17.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 8.83 | 19.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 3.83 | 20.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.17 | 20.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.58 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.55 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 24.50 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 1.33 | 20.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 5.83 | 19.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 24.67 | 16.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 89.00 | 17.53 | 0.00 | 1.50 | 24.54 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 28.17 | 20.46 | 0.00 | 0.00 | 0.67 | 24.58 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 34.50 | 16.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 20.67 | 16.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11.83 | 18.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 5.33 | 20.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.33 | 20.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 2.50 | 20.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 9.67 | 19.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 32.17 | 16.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 117.00 | 17.22 | 0.00 | 0.17 | 24.48 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 34.50 | 20.33 | 0.00 | 0.00 | 0.17 | 24.48 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.11 | 414.00 | 21.11 | 414.00 | 21.11 |
February | 376.00 | 21.11 | 376.00 | 21.11 | 376.00 | 21.11 |
March | 422.00 | 21.11 | 415.50 | 21.11 | 415.50 | 21.11 |
April | 405.00 | 21.67 | 245.17 | 21.12 | 245.17 | 21.12 |
May | 317.83 | 23.13 | 34.83 | 22.64 | 15.83 | 21.14 |
June | 147.33 | 23.59 | 136.00 | 23.89 | 19.33 | 23.88 |
July | 38.00 | 23.71 | 268.83 | 23.89 | 17.00 | 23.89 |
August | 41.00 | 23.58 | 228.17 | 23.89 | 0.00 | 0.00 |
September | 266.50 | 23.32 | 34.50 | 23.89 | 0.00 | 0.00 |
October | 414.00 | 22.04 | 101.67 | 21.11 | 101.67 | 21.11 |
November | 399.00 | 21.19 | 328.33 | 21.11 | 328.33 | 21.11 |
December | 415.00 | 21.11 | 415.00 | 21.11 | 415.00 | 21.11 |
Annual Sum or Average | 3655.67 | 21.78 | 2998.00 | 21.75 | 2347.83 | 21.15 |
Minimum of Months | 38.00 | 21.11 | 34.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.71 | 415.50 | 23.89 | 415.50 | 23.89 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.11 | 405.00 | 21.11 | 405.00 | 21.11 |
February | 376.00 | 21.11 | 320.33 | 21.11 | 320.33 | 21.11 |
March | 422.00 | 21.16 | 246.67 | 21.11 | 246.67 | 21.11 |
April | 394.33 | 22.07 | 51.50 | 21.11 | 51.50 | 21.11 |
May | 165.83 | 23.06 | 98.33 | 23.81 | 2.83 | 21.11 |
June | 29.33 | 23.42 | 276.50 | 23.89 | 0.33 | 23.89 |
July | 21.17 | 23.80 | 384.17 | 23.89 | 16.67 | 23.89 |
August | 8.17 | 23.20 | 360.33 | 23.89 | 0.00 | 0.00 |
September | 97.17 | 22.88 | 103.50 | 23.89 | 0.00 | 0.00 |
October | 369.00 | 22.03 | 12.33 | 21.11 | 12.33 | 21.11 |
November | 399.00 | 21.29 | 189.83 | 21.11 | 189.83 | 21.11 |
December | 415.00 | 21.11 | 391.00 | 21.11 | 391.00 | 21.11 |
Annual Sum or Average | 3111.00 | 21.58 | 2839.50 | 22.30 | 1636.50 | 21.14 |
Minimum of Months | 8.17 | 21.11 | 12.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.80 | 405.00 | 23.89 | 405.00 | 23.89 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.11 | 386.33 | 21.11 | 386.33 | 21.11 |
February | 376.00 | 21.35 | 262.33 | 21.11 | 262.33 | 21.11 |
March | 420.50 | 21.51 | 239.17 | 21.11 | 239.17 | 21.11 |
April | 345.00 | 22.18 | 103.17 | 21.35 | 94.17 | 21.11 |
May | 169.33 | 23.13 | 110.00 | 23.76 | 5.17 | 21.11 |
June | 47.83 | 23.42 | 267.17 | 23.89 | 0.83 | 23.89 |
July | 9.67 | 23.63 | 375.33 | 23.89 | 2.83 | 23.89 |
August | 8.67 | 23.16 | 360.17 | 23.89 | 0.00 | 0.00 |
September | 85.83 | 22.99 | 199.33 | 23.89 | 0.00 | 0.00 |
October | 302.67 | 22.32 | 75.00 | 22.83 | 28.50 | 21.11 |
November | 395.00 | 21.65 | 180.67 | 21.11 | 180.67 | 21.11 |
December | 415.00 | 21.11 | 393.33 | 21.11 | 393.33 | 21.11 |
Annual Sum or Average | 2989.50 | 21.73 | 2952.00 | 22.39 | 1593.33 | 21.12 |
Minimum of Months | 8.67 | 21.11 | 75.00 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 420.50 | 23.63 | 393.33 | 23.89 | 393.33 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.11 | 399.00 | 21.11 | 399.00 | 21.11 |
February | 376.00 | 21.17 | 302.17 | 21.11 | 302.17 | 21.11 |
March | 422.00 | 21.22 | 302.67 | 21.11 | 302.67 | 21.11 |
April | 375.83 | 21.76 | 150.67 | 21.17 | 147.17 | 21.11 |
May | 231.33 | 22.72 | 91.50 | 23.58 | 10.33 | 21.11 |
June | 111.00 | 23.22 | 222.50 | 23.89 | 23.50 | 23.87 |
July | 42.33 | 23.49 | 352.83 | 23.89 | 20.50 | 23.89 |
August | 32.67 | 23.08 | 334.17 | 23.89 | 0.00 | 0.00 |
September | 154.83 | 22.53 | 146.83 | 23.89 | 1.00 | 23.89 |
October | 340.33 | 21.65 | 99.83 | 21.99 | 68.33 | 21.11 |
November | 399.00 | 21.28 | 242.67 | 21.11 | 242.67 | 21.11 |
December | 415.00 | 21.11 | 405.33 | 21.11 | 405.33 | 21.11 |
Annual Sum or Average | 3314.33 | 21.58 | 3050.17 | 22.18 | 1922.67 | 21.17 |
Minimum of Months | 32.67 | 21.11 | 91.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.49 | 405.33 | 23.89 | 405.33 | 23.89 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10988 | 13.23015 | -0.8374 | 19.94140 |
February | 376.00000 | 21.10991 | 15.05670 | -0.7919 | 18.37987 |
March | 422.00000 | 21.11335 | 19.26841 | -0.7296 | 16.41500 |
April | 405.00000 | 21.66464 | 23.98593 | -0.4898 | 11.35246 |
May | 418.00000 | 23.29193 | 35.63914 | -0.9367 | 25.96839 |
June | 408.00000 | 23.76992 | 47.84290 | -0.6063 | 13.54183 |
July | 415.00000 | 23.86949 | 51.59545 | -0.4765 | 9.96053 |
August | 422.00000 | 23.85431 | 50.57153 | -0.5146 | 10.81332 |
September | 405.00000 | 23.49516 | 42.57013 | -0.7818 | 19.37514 |
October | 414.00000 | 22.03081 | 33.94548 | -0.2862 | 8.46201 |
November | 399.00000 | 21.19320 | 23.26713 | -0.6378 | 14.09620 |
December | 415.00000 | 21.10989 | 14.76625 | -0.8069 | 18.90269 |
Annual Sum or Average | 4913.00000 | 22.31230 | 31.11346 | -0.6572 | 15.58871 |
Minimum of Months | 376.00000 | 21.10988 | 13.23015 | -0.9367 | 8.46201 |
Maximum of Months | 422.00000 | 23.86949 | 51.59545 | -0.2862 | 25.96839 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10988 | 10.75256 | -0.7045 | 15.58867 |
February | 376.00000 | 21.11412 | 12.85574 | -0.6450 | 13.90561 |
March | 422.00000 | 21.15900 | 16.84026 | -0.5611 | 11.90392 |
April | 405.00000 | 22.10463 | 21.51151 | -0.2428 | 7.98450 |
May | 418.00000 | 23.54502 | 33.28115 | -0.6813 | 16.64700 |
June | 408.00000 | 23.84926 | 45.67343 | -0.4372 | 9.42094 |
July | 415.00000 | 23.88261 | 50.60586 | -0.3588 | 7.85835 |
August | 422.00000 | 23.87228 | 49.21652 | -0.3943 | 8.45787 |
September | 405.00000 | 23.63058 | 39.97872 | -0.6034 | 13.67412 |
October | 414.00000 | 22.22622 | 31.19996 | -0.1346 | 7.20519 |
November | 399.00000 | 21.29406 | 20.91345 | -0.4956 | 10.88383 |
December | 415.00000 | 21.10991 | 12.34675 | -0.6784 | 14.83558 |
Annual Sum or Average | 4913.00000 | 22.41941 | 28.90244 | -0.4940 | 11.51891 |
Minimum of Months | 376.00000 | 21.10988 | 10.75256 | -0.7045 | 7.20519 |
Maximum of Months | 422.00000 | 23.88261 | 50.60586 | -0.1346 | 16.64700 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10977 | 10.27126 | -0.7300 | 16.55298 |
February | 376.00000 | 21.34764 | 12.14296 | -0.5917 | 13.60815 |
March | 422.00000 | 21.51720 | 16.01145 | -0.5049 | 12.03888 |
April | 405.00000 | 22.41554 | 20.61809 | -0.1934 | 8.58246 |
May | 418.00000 | 23.56033 | 32.53397 | -0.6791 | 17.20967 |
June | 408.00000 | 23.82564 | 44.63740 | -0.4441 | 9.94895 |
July | 415.00000 | 23.88140 | 48.61913 | -0.3274 | 7.56062 |
August | 422.00000 | 23.87202 | 46.93447 | -0.3455 | 7.96011 |
September | 405.00000 | 23.68247 | 38.75402 | -0.5327 | 12.60827 |
October | 414.00000 | 22.72661 | 29.71632 | -0.0189 | 7.81629 |
November | 399.00000 | 21.66680 | 20.08487 | -0.4334 | 10.83102 |
December | 415.00000 | 21.11259 | 11.85219 | -0.7232 | 16.29795 |
Annual Sum or Average | 4913.00000 | 22.56983 | 27.81401 | -0.4599 | 11.74498 |
Minimum of Months | 376.00000 | 21.10977 | 10.27126 | -0.7300 | 7.56062 |
Maximum of Months | 422.00000 | 23.88140 | 48.61913 | -0.0189 | 17.20967 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.10974 | 10.32752 | -0.7654 | 17.64425 |
February | 376.00000 | 21.17246 | 12.30215 | -0.6634 | 14.92925 |
March | 422.00000 | 21.22105 | 16.28036 | -0.6045 | 13.47722 |
April | 405.00000 | 21.90981 | 21.07302 | -0.3334 | 9.83518 |
May | 418.00000 | 23.22437 | 33.43742 | -0.8311 | 22.84108 |
June | 408.00000 | 23.68969 | 46.71672 | -0.5315 | 12.38524 |
July | 415.00000 | 23.84169 | 50.85218 | -0.3792 | 8.49732 |
August | 422.00000 | 23.81738 | 49.21459 | -0.4032 | 9.08117 |
September | 405.00000 | 23.35017 | 40.38613 | -0.6771 | 17.37605 |
October | 414.00000 | 22.03804 | 30.85748 | -0.1946 | 8.57029 |
November | 399.00000 | 21.28313 | 20.60023 | -0.5494 | 12.33088 |
December | 415.00000 | 21.10983 | 11.91302 | -0.7595 | 17.40495 |
Annual Sum or Average | 4913.00000 | 22.32456 | 28.80324 | -0.5572 | 13.69359 |
Minimum of Months | 376.00000 | 21.10974 | 10.32752 | -0.8311 | 8.49732 |
Maximum of Months | 422.00000 | 23.84169 | 50.85218 | -0.1946 | 22.84108 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.123042E+09 | 38027800.09 | 24.00 | 0.117197E+09 | 5844652.07 | 0.00 | 0.17 | 23-APR-16:00 | 0.00 | 01-APR-00:10 | 4342.24 | 23-APR-16:00 | 3766.15 | 23-APR-16:00 | 576.10 | 23-APR-16:00 | 1398.93 | 23-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.478153E+10 | 0.141774E+10 | 246.22 | 0.412475E+10 | 0.656778E+09 | 0.00 | 0.53 | 25-MAY-15:00 | 0.00 | 01-MAY-00:10 | 15551.03 | 25-MAY-15:00 | 12265.84 | 25-MAY-15:00 | 3676.51 | 26-MAY-12:00 | 4659.71 | 25-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.112039E+11 | 0.325760E+10 | 364.44 | 0.864441E+10 | 0.255954E+10 | 0.00 | 1.00 | 29-JUN-04:02 | 0.00 | 01-JUN-00:10 | 38119.92 | 30-JUN-04:01 | 23328.00 | 29-JUN-04:02 | 20157.38 | 30-JUN-04:06 | 8717.15 | 30-JUN-04:05 | 0.00 | 01-JUN-00:10 |
July | 0.160822E+11 | 0.460617E+10 | 417.32 | 0.119837E+11 | 0.409855E+10 | 0.00 | 1.00 | 04-JUL-06:02 | 0.00 | 01-JUL-00:10 | 37213.26 | 04-JUL-06:02 | 25893.49 | 25-JUL-04:02 | 18289.62 | 04-JUL-06:02 | 8365.89 | 04-JUL-06:02 | 0.00 | 01-JUL-00:10 |
August | 0.133090E+11 | 0.378596E+10 | 407.23 | 0.100188E+11 | 0.329022E+10 | 0.00 | 1.00 | 09-AUG-04:02 | 0.00 | 01-AUG-00:10 | 35920.84 | 09-AUG-04:02 | 25051.48 | 23-AUG-04:02 | 13337.82 | 09-AUG-04:02 | 8181.95 | 09-AUG-04:02 | 0.00 | 01-AUG-00:10 |
September | 0.461290E+10 | 0.133964E+10 | 269.95 | 0.383288E+10 | 0.780021E+09 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 35898.24 | 01-SEP-04:02 | 21589.02 | 01-SEP-04:02 | 14309.22 | 01-SEP-04:02 | 8178.96 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 |
October | 0.369347E+09 | 0.110213E+09 | 44.42 | 0.336594E+09 | 32753380.89 | 0.00 | 0.20 | 21-OCT-15:50 | 0.00 | 01-OCT-00:10 | 5256.21 | 21-OCT-15:50 | 4912.60 | 21-OCT-15:38 | 650.53 | 19-OCT-15:00 | 1557.26 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.504820E+11 | 0.145554E+11 | 1773.58 | 0.390583E+11 | 0.114237E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.160822E+11 | 0.460617E+10 | 417.32 | 0.119837E+11 | 0.409855E+10 | 0.00 | 1.00 | 0.00 | 38119.92 | 25893.49 | 20157.38 | 8717.15 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.431678E+10 | 0.138473E+10 | 74.01 | 0.420525E+10 | 0.111529E+09 | 0.00 | 0.34 | 23-APR-16:00 | 0.00 | 01-APR-00:10 | 45283.65 | 23-APR-16:00 | 39908.55 | 23-APR-16:00 | 5375.11 | 23-APR-16:00 | 15061.25 | 23-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.365542E+11 | 0.114894E+11 | 314.91 | 0.325485E+11 | 0.400572E+10 | 0.00 | 1.00 | 19-MAY-04:03 | 0.00 | 01-MAY-00:10 | 168207.40 | 26-MAY-04:02 | 145881.26 | 19-MAY-04:03 | 38242.92 | 27-MAY-04:03 | 41945.05 | 26-MAY-04:02 | 0.00 | 01-MAY-00:10 |
June | 0.710999E+11 | 0.218774E+11 | 398.29 | 0.554268E+11 | 0.156732E+11 | 0.00 | 1.00 | 22-JUN-04:03 | 0.00 | 01-JUN-00:10 | 180292.90 | 30-JUN-04:01 | 128174.79 | 22-JUN-04:03 | 73565.32 | 30-JUN-04:13 | 45825.07 | 30-JUN-04:01 | 0.00 | 01-JUN-00:10 |
July | 0.927237E+11 | 0.282175E+11 | 436.66 | 0.684211E+11 | 0.243026E+11 | 0.00 | 1.00 | 01-JUL-04:02 | 0.00 | 01-JUL-00:10 | 178337.63 | 04-JUL-06:02 | 132765.91 | 07-JUL-04:03 | 72816.81 | 04-JUL-06:04 | 43807.23 | 04-JUL-06:02 | 0.00 | 01-JUL-00:10 |
August | 0.773139E+11 | 0.234758E+11 | 432.05 | 0.578125E+11 | 0.195013E+11 | 0.00 | 1.00 | 01-AUG-04:02 | 0.00 | 01-AUG-00:10 | 173561.09 | 09-AUG-04:02 | 130064.69 | 01-AUG-04:02 | 58988.36 | 29-AUG-04:03 | 42895.77 | 09-AUG-04:02 | 0.00 | 01-AUG-00:10 |
September | 0.297244E+11 | 0.924862E+10 | 304.76 | 0.250703E+11 | 0.465413E+10 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 173176.75 | 01-SEP-04:02 | 130890.64 | 02-SEP-04:02 | 62395.25 | 01-SEP-04:02 | 42836.23 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 |
October | 0.392783E+10 | 0.125257E+10 | 71.27 | 0.361673E+10 | 0.311100E+09 | 0.00 | 0.29 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 | 38519.86 | 19-OCT-15:00 | 34914.57 | 19-OCT-15:00 | 5111.07 | 07-OCT-14:00 | 12100.97 | 19-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.279326E+09 | 90583304.88 | 6.83 | 0.224437E+09 | 54889574.41 | 0.00 | 0.15 | 01-NOV-15:00 | 0.00 | 01-NOV-00:10 | 18995.08 | 01-NOV-15:00 | 15194.94 | 01-NOV-15:00 | 3800.14 | 01-NOV-15:00 | 6099.05 | 01-NOV-15:00 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.315940E+12 | 0.970366E+11 | 2038.78 | 0.247326E+12 | 0.686145E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.927237E+11 | 0.282175E+11 | 436.66 | 0.684211E+11 | 0.243026E+11 | 0.00 | 1.00 | 0.00 | 180292.90 | 145881.26 | 73565.32 | 45825.07 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 24767315.30 | 7461895.54 | 8.67 | 24767315.30 | 0.00 | 0.00 | 0.11 | 28-FEB-15:10 | 0.00 | 01-FEB-00:02 | 1767.84 | 28-FEB-15:10 | 1767.84 | 28-FEB-15:10 | 0.00 | 28-FEB-14:50 | 526.89 | 28-FEB-15:10 | 0.00 | 01-FEB-00:02 |
March | 64920704.26 | 19448528.80 | 20.00 | 64920704.26 | 0.00 | 0.00 | 0.17 | 31-MAR-14:30 | 0.00 | 01-MAR-00:10 | 2762.70 | 31-MAR-14:30 | 2762.70 | 31-MAR-14:30 | 0.00 | 29-MAR-12:10 | 810.86 | 31-MAR-14:30 | 0.00 | 01-MAR-00:10 |
April | 0.149928E+10 | 0.431011E+09 | 127.14 | 0.148751E+10 | 11771671.24 | 0.00 | 0.45 | 23-APR-14:20 | 0.00 | 01-APR-00:10 | 8350.52 | 23-APR-14:20 | 7715.07 | 23-APR-14:20 | 640.49 | 23-APR-14:40 | 2423.52 | 23-APR-14:30 | 0.00 | 01-APR-00:10 |
May | 0.593134E+10 | 0.170670E+10 | 340.61 | 0.551187E+10 | 0.419465E+09 | 0.00 | 1.00 | 26-MAY-04:02 | 0.00 | 01-MAY-00:10 | 22912.87 | 26-MAY-04:02 | 18387.65 | 26-MAY-04:02 | 4525.21 | 26-MAY-04:02 | 5271.89 | 26-MAY-04:02 | 0.00 | 01-MAY-00:10 |
June | 0.987827E+10 | 0.281048E+10 | 394.73 | 0.816429E+10 | 0.171399E+10 | 0.00 | 1.00 | 28-JUN-04:02 | 0.00 | 01-JUN-00:10 | 25252.20 | 30-JUN-04:01 | 17219.14 | 28-JUN-04:02 | 12654.02 | 30-JUN-04:05 | 5737.15 | 30-JUN-04:05 | 0.00 | 01-JUN-00:10 |
July | 0.132449E+11 | 0.371665E+10 | 439.65 | 0.104951E+11 | 0.274988E+10 | 0.00 | 1.00 | 01-JUL-04:02 | 0.00 | 01-JUL-00:10 | 24592.56 | 04-JUL-06:02 | 18392.12 | 01-JUL-04:02 | 11316.13 | 04-JUL-06:02 | 5512.15 | 04-JUL-06:02 | 0.00 | 01-JUL-00:10 |
August | 0.121906E+11 | 0.337379E+10 | 440.80 | 0.988283E+10 | 0.230778E+10 | 0.00 | 1.00 | 01-AUG-04:02 | 0.00 | 01-AUG-00:10 | 23767.51 | 09-AUG-04:02 | 18816.90 | 25-AUG-04:02 | 7975.89 | 09-AUG-04:03 | 5401.09 | 09-AUG-04:02 | 0.00 | 01-AUG-00:10 |
September | 0.653421E+10 | 0.182416E+10 | 342.73 | 0.595007E+10 | 0.584147E+09 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 23695.96 | 01-SEP-04:02 | 19655.35 | 02-SEP-04:02 | 8501.05 | 01-SEP-04:02 | 5392.07 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 |
October | 0.210798E+10 | 0.592724E+09 | 157.49 | 0.204608E+10 | 61901159.20 | 0.00 | 0.58 | 19-OCT-14:10 | 0.00 | 01-OCT-00:10 | 11035.22 | 19-OCT-14:10 | 10517.93 | 19-OCT-14:10 | 795.61 | 07-OCT-13:50 | 2942.31 | 19-OCT-14:20 | 0.00 | 01-OCT-00:10 |
November | 0.170445E+09 | 50349177.53 | 24.86 | 0.158052E+09 | 12392869.12 | 0.00 | 0.24 | 17-NOV-13:30 | 0.00 | 01-NOV-00:10 | 4048.35 | 17-NOV-13:30 | 4048.35 | 17-NOV-13:30 | 516.46 | 01-NOV-15:00 | 1165.27 | 17-NOV-13:30 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.516468E+11 | 0.145328E+11 | 2296.67 | 0.437854E+11 | 0.786132E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.132449E+11 | 0.371665E+10 | 440.80 | 0.104951E+11 | 0.274988E+10 | 0.00 | 1.00 | 0.00 | 25252.20 | 19655.35 | 12654.02 | 5737.15 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 17791.68 | 4875.77 | 0.33 | 17791.68 | 0.00 | 0.00 | 0.00 | 31-MAR-14:50 | 0.00 | 01-MAR-00:10 | 23.21 | 31-MAR-14:50 | 23.21 | 31-MAR-14:50 | 0.00 | 01-MAR-00:10 | 6.36 | 31-MAR-14:50 | 0.00 | 01-MAR-00:10 |
April | 0.604073E+09 | 0.157980E+09 | 72.07 | 0.592516E+09 | 11557597.72 | 0.00 | 0.39 | 23-APR-14:30 | 0.00 | 01-APR-00:10 | 5900.38 | 23-APR-14:20 | 5309.88 | 23-APR-14:20 | 593.00 | 23-APR-14:30 | 1560.38 | 23-APR-14:30 | 0.00 | 01-APR-00:10 |
May | 0.323824E+10 | 0.846652E+09 | 245.63 | 0.289759E+10 | 0.340648E+09 | 0.00 | 0.76 | 26-MAY-04:02 | 0.00 | 01-MAY-00:10 | 12705.69 | 26-MAY-04:02 | 9942.96 | 26-MAY-04:02 | 2762.73 | 26-MAY-04:02 | 2942.56 | 26-MAY-04:02 | 0.00 | 01-MAY-00:10 |
June | 0.643648E+10 | 0.165646E+10 | 341.71 | 0.505312E+10 | 0.138336E+10 | 0.00 | 1.00 | 29-JUN-04:02 | 0.00 | 01-JUN-00:10 | 21121.69 | 30-JUN-04:01 | 12865.99 | 29-JUN-04:02 | 11067.43 | 30-JUN-04:05 | 4304.26 | 30-JUN-04:13 | 0.00 | 01-JUN-00:10 |
July | 0.950064E+10 | 0.240485E+10 | 405.20 | 0.715286E+10 | 0.234778E+10 | 0.00 | 1.00 | 04-JUL-06:02 | 0.00 | 01-JUL-00:10 | 20595.24 | 04-JUL-06:02 | 14067.81 | 25-JUL-04:02 | 10267.07 | 04-JUL-06:02 | 4133.87 | 04-JUL-06:02 | 0.00 | 01-JUL-00:10 |
August | 0.835281E+10 | 0.208414E+10 | 391.82 | 0.645241E+10 | 0.190040E+10 | 0.00 | 1.00 | 09-AUG-04:02 | 0.00 | 01-AUG-00:10 | 19864.36 | 09-AUG-04:02 | 14121.30 | 26-AUG-04:02 | 7264.84 | 09-AUG-04:02 | 4044.37 | 09-AUG-04:02 | 0.00 | 01-AUG-00:10 |
September | 0.366436E+10 | 0.920836E+09 | 246.17 | 0.326043E+10 | 0.403921E+09 | 0.00 | 1.00 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 | 19802.62 | 01-SEP-04:02 | 12847.71 | 02-SEP-04:02 | 8020.62 | 01-SEP-04:02 | 4037.10 | 01-SEP-04:02 | 0.00 | 01-SEP-00:10 |
October | 0.992702E+09 | 0.249316E+09 | 74.80 | 0.954525E+09 | 38176964.84 | 0.00 | 0.53 | 19-OCT-14:20 | 0.00 | 01-OCT-00:10 | 8363.10 | 19-OCT-14:20 | 7825.10 | 19-OCT-14:20 | 701.59 | 22-OCT-12:40 | 2024.39 | 19-OCT-14:30 | 0.00 | 01-OCT-00:10 |
November | 15614864.08 | 4215621.66 | 5.75 | 14906977.44 | 707886.64 | 0.00 | 0.09 | 17-NOV-13:50 | 0.00 | 01-NOV-00:10 | 1245.60 | 17-NOV-13:50 | 1245.60 | 17-NOV-13:50 | 138.46 | 01-NOV-15:00 | 333.56 | 17-NOV-13:50 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.328049E+11 | 0.832445E+10 | 1783.49 | 0.263784E+11 | 0.642655E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.950064E+10 | 0.240485E+10 | 405.20 | 0.715286E+10 | 0.234778E+10 | 0.00 | 1.00 | 0.00 | 21121.69 | 14121.30 | 11067.43 | 4304.26 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 10.23 | 3.12 | 7.11 | 0.03 | 81.25 | 0.00 | 0.00 | 744.00 |
February | 18.49 | 8.03 | 10.46 | 2.41 | 63.71 | 0.00 | 0.00 | 672.00 |
March | 27.08 | 14.96 | 12.12 | 12.90 | 49.60 | 0.00 | 0.00 | 744.00 |
April | 40.81 | 25.75 | 15.06 | 32.32 | 32.82 | 0.00 | 0.00 | 720.00 |
May | 50.44 | 28.56 | 21.88 | 49.40 | 20.28 | 0.00 | 0.00 | 744.00 |
June | 53.19 | 30.86 | 22.33 | 56.39 | 15.05 | 0.00 | 0.00 | 720.00 |
July | 54.61 | 32.86 | 21.75 | 59.66 | 14.30 | 0.00 | 0.00 | 744.00 |
August | 42.82 | 24.13 | 18.70 | 44.14 | 15.56 | 0.00 | 0.00 | 744.00 |
September | 30.65 | 15.62 | 15.03 | 25.56 | 22.96 | 0.00 | 0.00 | 720.00 |
October | 17.89 | 6.82 | 11.07 | 8.05 | 33.57 | 0.00 | 0.00 | 744.00 |
November | 10.14 | 2.72 | 7.42 | 0.57 | 49.83 | 0.00 | 0.00 | 720.00 |
December | 8.06 | 1.73 | 6.33 | 0.00 | 77.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 30.43 | 16.30 | 14.12 | 24.42 | 39.65 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 8.06 | 1.73 | 6.33 | 0.00 | 14.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 54.61 | 32.86 | 22.33 | 59.66 | 81.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1542.81 | 1073.16 | 469.65 | 1162.06 | 1805.01 | 0.00 | 0.00 | 744.00 |
February | 1954.07 | 1319.82 | 634.25 | 1660.28 | 1519.22 | 0.00 | 0.00 | 672.00 |
March | 1722.64 | 1090.48 | 632.16 | 1418.24 | 1279.03 | 0.00 | 0.00 | 744.00 |
April | 1560.16 | 846.91 | 713.25 | 1301.95 | 850.80 | 0.00 | 0.00 | 720.00 |
May | 1311.30 | 448.16 | 863.13 | 1119.19 | 492.23 | 0.00 | 0.00 | 744.00 |
June | 1176.59 | 313.47 | 863.12 | 1062.83 | 347.47 | 0.00 | 0.00 | 720.00 |
July | 1286.39 | 407.38 | 879.02 | 1232.65 | 326.63 | 0.00 | 0.00 | 744.00 |
August | 1373.97 | 574.69 | 799.28 | 1354.02 | 386.95 | 0.00 | 0.00 | 744.00 |
September | 1472.28 | 784.33 | 687.95 | 1414.76 | 601.45 | 0.00 | 0.00 | 720.00 |
October | 1257.16 | 739.54 | 517.61 | 1108.99 | 863.02 | 0.00 | 0.00 | 744.00 |
November | 1119.24 | 702.32 | 416.91 | 907.81 | 1179.03 | 0.00 | 0.00 | 720.00 |
December | 1191.25 | 780.99 | 410.25 | 819.95 | 1755.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1410.45 | 753.18 | 657.26 | 1210.35 | 948.13 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 1119.24 | 313.47 | 410.25 | 819.95 | 326.63 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1954.07 | 1319.82 | 879.02 | 1660.28 | 1805.01 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1542.81 | 1073.16 | 469.65 | 1159.81 | 1801.50 | 0.00 | 0.00 | 744.00 |
February | 1954.07 | 1319.82 | 634.25 | 1661.23 | 1508.79 | 0.00 | 0.00 | 672.00 |
March | 1722.64 | 1090.48 | 632.16 | 1422.22 | 1260.40 | 0.00 | 0.00 | 744.00 |
April | 1560.16 | 846.91 | 713.25 | 1309.31 | 825.04 | 0.00 | 0.00 | 720.00 |
May | 1311.30 | 448.16 | 863.13 | 1125.19 | 471.01 | 0.00 | 0.00 | 744.00 |
June | 1176.59 | 313.47 | 863.12 | 1064.74 | 330.75 | 0.00 | 0.00 | 720.00 |
July | 1286.39 | 407.38 | 879.02 | 1230.43 | 313.35 | 0.00 | 0.00 | 744.00 |
August | 1373.97 | 574.69 | 799.28 | 1351.83 | 373.08 | 0.00 | 0.00 | 744.00 |
September | 1472.28 | 784.33 | 687.95 | 1418.47 | 579.46 | 0.00 | 0.00 | 720.00 |
October | 1257.16 | 739.54 | 517.61 | 1118.11 | 830.33 | 0.00 | 0.00 | 744.00 |
November | 1119.24 | 702.32 | 416.91 | 912.16 | 1157.87 | 0.00 | 0.00 | 720.00 |
December | 1191.25 | 780.99 | 410.25 | 818.41 | 1752.02 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1410.45 | 753.18 | 657.26 | 1212.77 | 931.21 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 1119.24 | 313.47 | 410.25 | 818.41 | 313.35 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1954.07 | 1319.82 | 879.02 | 1661.23 | 1801.50 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 317.46 | 220.82 | 96.64 | 230.19 | 379.73 | 0.00 | 0.00 | 744.00 |
February | 402.08 | 271.57 | 130.51 | 329.68 | 317.59 | 0.00 | 0.00 | 672.00 |
March | 354.46 | 224.38 | 130.08 | 282.99 | 268.35 | 0.00 | 0.00 | 744.00 |
April | 321.03 | 174.26 | 146.76 | 262.40 | 172.80 | 0.00 | 0.00 | 720.00 |
May | 269.82 | 92.22 | 177.60 | 228.06 | 95.08 | 0.00 | 0.00 | 744.00 |
June | 242.10 | 64.50 | 177.60 | 214.69 | 66.07 | 0.00 | 0.00 | 720.00 |
July | 264.69 | 83.82 | 180.87 | 246.61 | 64.57 | 0.00 | 0.00 | 744.00 |
August | 282.71 | 118.25 | 164.46 | 275.06 | 75.25 | 0.00 | 0.00 | 744.00 |
September | 302.94 | 161.39 | 141.56 | 289.30 | 116.00 | 0.00 | 0.00 | 720.00 |
October | 258.68 | 152.17 | 106.51 | 224.86 | 171.90 | 0.00 | 0.00 | 744.00 |
November | 230.30 | 144.51 | 85.79 | 178.56 | 246.25 | 0.00 | 0.00 | 720.00 |
December | 245.12 | 160.70 | 84.42 | 161.63 | 371.72 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 290.22 | 154.98 | 135.24 | 243.04 | 194.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 230.30 | 64.50 | 84.42 | 161.63 | 64.57 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 402.08 | 271.57 | 180.87 | 329.68 | 379.73 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 27388968.73 | 8345530.45 | 19043438.28 | 78882.13 | 0.217610E+09 |
February | 44734636.40 | 19434402.45 | 25300233.95 | 5839843.79 | 0.154138E+09 |
March | 72541354.00 | 40070568.85 | 32470785.15 | 34558246.14 | 0.132854E+09 |
April | 0.105775E+09 | 66731534.12 | 39043224.75 | 83770427.00 | 85077380.44 |
May | 0.135100E+09 | 76499656.28 | 58599984.38 | 0.132324E+09 | 54315080.13 |
June | 0.137866E+09 | 79997476.06 | 57868532.10 | 0.146162E+09 | 39005230.06 |
July | 0.146260E+09 | 87999815.14 | 58259731.22 | 0.159780E+09 | 38304757.68 |
August | 0.114699E+09 | 64625426.36 | 50073296.68 | 0.118227E+09 | 41676434.41 |
September | 79447906.33 | 40492126.77 | 38955779.56 | 66241053.29 | 59513555.58 |
October | 47916515.53 | 18279134.41 | 29637381.12 | 21571018.86 | 89912243.53 |
November | 26270969.90 | 7049349.83 | 19221620.08 | 1476701.89 | 0.129170E+09 |
December | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 0.208796E+09 |
Annual Sum or Average | 0.959575E+09 | 0.514155E+09 | 0.445421E+09 | 0.770028E+09 | 0.125037E+10 |
Minimum of Months | 21576440.51 | 4629622.04 | 16946818.47 | 0.00 | 38304757.68 |
Maximum of Months | 0.146260E+09 | 87999815.14 | 58599984.38 | 0.159780E+09 | 0.217610E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.413226E+10 | 0.287434E+10 | 0.125792E+10 | 0.311245E+10 | 0.483453E+10 |
February | 0.472728E+10 | 0.319290E+10 | 0.153439E+10 | 0.401654E+10 | 0.367531E+10 |
March | 0.461392E+10 | 0.292075E+10 | 0.169318E+10 | 0.379862E+10 | 0.342575E+10 |
April | 0.404395E+10 | 0.219520E+10 | 0.184875E+10 | 0.337466E+10 | 0.220527E+10 |
May | 0.351217E+10 | 0.120036E+10 | 0.231181E+10 | 0.299763E+10 | 0.131839E+10 |
June | 0.304972E+10 | 0.812512E+09 | 0.223721E+10 | 0.275486E+10 | 0.900650E+09 |
July | 0.344548E+10 | 0.109112E+10 | 0.235436E+10 | 0.330153E+10 | 0.874852E+09 |
August | 0.368004E+10 | 0.153925E+10 | 0.214079E+10 | 0.362662E+10 | 0.103641E+10 |
September | 0.381615E+10 | 0.203299E+10 | 0.178317E+10 | 0.366705E+10 | 0.155896E+10 |
October | 0.336717E+10 | 0.198079E+10 | 0.138638E+10 | 0.297031E+10 | 0.231152E+10 |
November | 0.290106E+10 | 0.182043E+10 | 0.108064E+10 | 0.235305E+10 | 0.305605E+10 |
December | 0.319063E+10 | 0.209181E+10 | 0.109882E+10 | 0.219616E+10 | 0.470255E+10 |
Annual Sum or Average | 0.444798E+11 | 0.237524E+11 | 0.207274E+11 | 0.381695E+11 | 0.299002E+11 |
Minimum of Months | 0.290106E+10 | 0.812512E+09 | 0.108064E+10 | 0.219616E+10 | 0.874852E+09 |
Maximum of Months | 0.472728E+10 | 0.319290E+10 | 0.235436E+10 | 0.401654E+10 | 0.483453E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.413226E+10 | 0.287434E+10 | 0.125792E+10 | 0.310643E+10 | 0.482513E+10 |
February | 0.472728E+10 | 0.319290E+10 | 0.153439E+10 | 0.401884E+10 | 0.365006E+10 |
March | 0.461392E+10 | 0.292075E+10 | 0.169318E+10 | 0.380928E+10 | 0.337585E+10 |
April | 0.404395E+10 | 0.219520E+10 | 0.184875E+10 | 0.339374E+10 | 0.213850E+10 |
May | 0.351217E+10 | 0.120036E+10 | 0.231181E+10 | 0.301371E+10 | 0.126155E+10 |
June | 0.304972E+10 | 0.812512E+09 | 0.223721E+10 | 0.275980E+10 | 0.857313E+09 |
July | 0.344548E+10 | 0.109112E+10 | 0.235436E+10 | 0.329558E+10 | 0.839265E+09 |
August | 0.368004E+10 | 0.153925E+10 | 0.214079E+10 | 0.362075E+10 | 0.999259E+09 |
September | 0.381615E+10 | 0.203299E+10 | 0.178317E+10 | 0.367668E+10 | 0.150197E+10 |
October | 0.336717E+10 | 0.198079E+10 | 0.138638E+10 | 0.299474E+10 | 0.222395E+10 |
November | 0.290106E+10 | 0.182043E+10 | 0.108064E+10 | 0.236431E+10 | 0.300121E+10 |
December | 0.319063E+10 | 0.209181E+10 | 0.109882E+10 | 0.219204E+10 | 0.469261E+10 |
Annual Sum or Average | 0.444798E+11 | 0.237524E+11 | 0.207274E+11 | 0.382459E+11 | 0.293667E+11 |
Minimum of Months | 0.290106E+10 | 0.812512E+09 | 0.108064E+10 | 0.219204E+10 | 0.839265E+09 |
Maximum of Months | 0.472728E+10 | 0.319290E+10 | 0.235436E+10 | 0.401884E+10 | 0.482513E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.850274E+09 | 0.591437E+09 | 0.258836E+09 | 0.616543E+09 | 0.101707E+10 |
February | 0.972707E+09 | 0.656985E+09 | 0.315722E+09 | 0.797554E+09 | 0.768314E+09 |
March | 0.949382E+09 | 0.600986E+09 | 0.348396E+09 | 0.757957E+09 | 0.718761E+09 |
April | 0.832101E+09 | 0.451694E+09 | 0.380406E+09 | 0.680134E+09 | 0.447909E+09 |
May | 0.722681E+09 | 0.246992E+09 | 0.475689E+09 | 0.610830E+09 | 0.254675E+09 |
June | 0.627525E+09 | 0.167186E+09 | 0.460339E+09 | 0.556485E+09 | 0.171251E+09 |
July | 0.708958E+09 | 0.224513E+09 | 0.484444E+09 | 0.660512E+09 | 0.172954E+09 |
August | 0.757222E+09 | 0.316722E+09 | 0.440500E+09 | 0.736712E+09 | 0.201553E+09 |
September | 0.785229E+09 | 0.418316E+09 | 0.366912E+09 | 0.749862E+09 | 0.300665E+09 |
October | 0.692844E+09 | 0.407576E+09 | 0.285267E+09 | 0.602259E+09 | 0.460409E+09 |
November | 0.596936E+09 | 0.374579E+09 | 0.222357E+09 | 0.462824E+09 | 0.638279E+09 |
December | 0.656519E+09 | 0.430420E+09 | 0.226098E+09 | 0.432906E+09 | 0.995623E+09 |
Annual Sum or Average | 0.915238E+10 | 0.488741E+10 | 0.426497E+10 | 0.766458E+10 | 0.614747E+10 |
Minimum of Months | 0.596936E+09 | 0.167186E+09 | 0.222357E+09 | 0.432906E+09 | 0.171251E+09 |
Maximum of Months | 0.972707E+09 | 0.656985E+09 | 0.484444E+09 | 0.797554E+09 | 0.101707E+10 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.24 | 649.97 | 81.81 | 24.93 | 56.88 | 0.00 | 0.00 |
February | 19.31 | 509.71 | 147.93 | 64.27 | 83.66 | 0.00 | 0.00 |
March | 103.22 | 396.82 | 216.67 | 119.69 | 96.99 | 0.00 | 0.00 |
April | 258.55 | 262.58 | 326.47 | 205.96 | 120.50 | 0.00 | 0.00 |
May | 395.23 | 162.23 | 403.52 | 228.49 | 175.03 | 0.00 | 0.00 |
June | 451.12 | 120.39 | 425.51 | 246.91 | 178.61 | 0.00 | 0.00 |
July | 477.24 | 114.41 | 436.86 | 262.84 | 174.01 | 0.00 | 0.00 |
August | 353.13 | 124.48 | 342.59 | 193.03 | 149.56 | 0.00 | 0.00 |
September | 204.45 | 183.68 | 245.21 | 124.98 | 120.23 | 0.00 | 0.00 |
October | 64.43 | 268.56 | 143.12 | 54.60 | 88.52 | 0.00 | 0.00 |
November | 4.56 | 398.67 | 81.08 | 21.76 | 59.33 | 0.00 | 0.00 |
December | 0.00 | 623.64 | 64.45 | 13.83 | 50.62 | 0.00 | 0.00 |
Annual Sum or Average | 195.34 | 317.19 | 243.42 | 130.43 | 112.99 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 114.41 | 64.45 | 13.83 | 50.62 | 0.00 | 0.00 |
Maximum of Months | 477.24 | 649.97 | 436.86 | 262.84 | 178.61 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1162.06 | 1805.01 | 1542.81 | 1073.16 | 469.65 | 0.00 | 0.00 |
February | 1660.28 | 1519.22 | 1954.07 | 1319.82 | 634.25 | 0.00 | 0.00 |
March | 1418.24 | 1279.03 | 1722.64 | 1090.48 | 632.16 | 0.00 | 0.00 |
April | 1301.95 | 850.80 | 1560.16 | 846.91 | 713.25 | 0.00 | 0.00 |
May | 1119.19 | 492.23 | 1311.30 | 448.16 | 863.13 | 0.00 | 0.00 |
June | 1062.83 | 347.47 | 1176.59 | 313.47 | 863.12 | 0.00 | 0.00 |
July | 1232.65 | 326.63 | 1286.39 | 407.38 | 879.02 | 0.00 | 0.00 |
August | 1354.02 | 386.95 | 1373.97 | 574.69 | 799.28 | 0.00 | 0.00 |
September | 1414.76 | 601.45 | 1472.28 | 784.33 | 687.95 | 0.00 | 0.00 |
October | 1108.99 | 863.02 | 1257.16 | 739.54 | 517.61 | 0.00 | 0.00 |
November | 907.81 | 1179.03 | 1119.24 | 702.32 | 416.91 | 0.00 | 0.00 |
December | 819.95 | 1755.73 | 1191.25 | 780.99 | 410.25 | 0.00 | 0.00 |
Annual Sum or Average | 1210.35 | 948.13 | 1410.45 | 753.18 | 657.26 | 0.00 | 0.00 |
Minimum of Months | 819.95 | 326.63 | 1119.24 | 313.47 | 410.25 | 0.00 | 0.00 |
Maximum of Months | 1660.28 | 1805.01 | 1954.07 | 1319.82 | 879.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1159.81 | 1801.50 | 1542.81 | 1073.16 | 469.65 | 0.00 | 0.00 |
February | 1661.23 | 1508.79 | 1954.07 | 1319.82 | 634.25 | 0.00 | 0.00 |
March | 1422.22 | 1260.40 | 1722.64 | 1090.48 | 632.16 | 0.00 | 0.00 |
April | 1309.31 | 825.04 | 1560.16 | 846.91 | 713.25 | 0.00 | 0.00 |
May | 1125.19 | 471.01 | 1311.30 | 448.16 | 863.13 | 0.00 | 0.00 |
June | 1064.74 | 330.75 | 1176.59 | 313.47 | 863.12 | 0.00 | 0.00 |
July | 1230.43 | 313.35 | 1286.39 | 407.38 | 879.02 | 0.00 | 0.00 |
August | 1351.83 | 373.08 | 1373.97 | 574.69 | 799.28 | 0.00 | 0.00 |
September | 1418.47 | 579.46 | 1472.28 | 784.33 | 687.95 | 0.00 | 0.00 |
October | 1118.11 | 830.33 | 1257.16 | 739.54 | 517.61 | 0.00 | 0.00 |
November | 912.16 | 1157.87 | 1119.24 | 702.32 | 416.91 | 0.00 | 0.00 |
December | 818.41 | 1752.02 | 1191.25 | 780.99 | 410.25 | 0.00 | 0.00 |
Annual Sum or Average | 1212.77 | 931.21 | 1410.45 | 753.18 | 657.26 | 0.00 | 0.00 |
Minimum of Months | 818.41 | 313.35 | 1119.24 | 313.47 | 410.25 | 0.00 | 0.00 |
Maximum of Months | 1661.23 | 1801.50 | 1954.07 | 1319.82 | 879.02 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 230.19 | 379.73 | 317.46 | 220.82 | 96.64 | 0.00 | 0.00 |
February | 329.68 | 317.59 | 402.08 | 271.57 | 130.51 | 0.00 | 0.00 |
March | 282.99 | 268.35 | 354.46 | 224.38 | 130.08 | 0.00 | 0.00 |
April | 262.40 | 172.80 | 321.03 | 174.26 | 146.76 | 0.00 | 0.00 |
May | 228.06 | 95.08 | 269.82 | 92.22 | 177.60 | 0.00 | 0.00 |
June | 214.69 | 66.07 | 242.10 | 64.50 | 177.60 | 0.00 | 0.00 |
July | 246.61 | 64.57 | 264.69 | 83.82 | 180.87 | 0.00 | 0.00 |
August | 275.06 | 75.25 | 282.71 | 118.25 | 164.46 | 0.00 | 0.00 |
September | 289.30 | 116.00 | 302.94 | 161.39 | 141.56 | 0.00 | 0.00 |
October | 224.86 | 171.90 | 258.68 | 152.17 | 106.51 | 0.00 | 0.00 |
November | 178.56 | 246.25 | 230.30 | 144.51 | 85.79 | 0.00 | 0.00 |
December | 161.63 | 371.72 | 245.12 | 160.70 | 84.42 | 0.00 | 0.00 |
Annual Sum or Average | 243.04 | 194.93 | 290.22 | 154.98 | 135.24 | 0.00 | 0.00 |
Minimum of Months | 161.63 | 64.57 | 230.30 | 64.50 | 84.42 | 0.00 | 0.00 |
Maximum of Months | 329.68 | 379.73 | 402.08 | 271.57 | 180.87 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 631057.02 | 0.174088E+10 | 0.219112E+09 | 66764243.62 | 0.152348E+09 | 0.00 | 0.00 |
February | 46718750.31 | 0.123310E+10 | 0.357877E+09 | 0.155475E+09 | 0.202402E+09 | 0.00 | 0.00 |
March | 0.276466E+09 | 0.106283E+10 | 0.580331E+09 | 0.320565E+09 | 0.259766E+09 | 0.00 | 0.00 |
April | 0.670163E+09 | 0.680619E+09 | 0.846198E+09 | 0.533852E+09 | 0.312346E+09 | 0.00 | 0.00 |
May | 0.105859E+10 | 0.434521E+09 | 0.108080E+10 | 0.611997E+09 | 0.468800E+09 | 0.00 | 0.00 |
June | 0.116929E+10 | 0.312042E+09 | 0.110293E+10 | 0.639980E+09 | 0.462948E+09 | 0.00 | 0.00 |
July | 0.127824E+10 | 0.306438E+09 | 0.117008E+10 | 0.703999E+09 | 0.466078E+09 | 0.00 | 0.00 |
August | 0.945812E+09 | 0.333411E+09 | 0.917590E+09 | 0.517003E+09 | 0.400586E+09 | 0.00 | 0.00 |
September | 0.529928E+09 | 0.476108E+09 | 0.635583E+09 | 0.323937E+09 | 0.311646E+09 | 0.00 | 0.00 |
October | 0.172568E+09 | 0.719298E+09 | 0.383332E+09 | 0.146233E+09 | 0.237099E+09 | 0.00 | 0.00 |
November | 11813615.15 | 0.103336E+10 | 0.210168E+09 | 56394798.63 | 0.153773E+09 | 0.00 | 0.00 |
December | 0.00 | 0.167037E+10 | 0.172612E+09 | 37036976.35 | 0.135575E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.616023E+10 | 0.100030E+11 | 0.767660E+10 | 0.411324E+10 | 0.356337E+10 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.306438E+09 | 0.172612E+09 | 37036976.35 | 0.135575E+09 | 0.00 | 0.00 |
Maximum of Months | 0.127824E+10 | 0.174088E+10 | 0.117008E+10 | 0.703999E+09 | 0.468800E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.311245E+10 | 0.483453E+10 | 0.413226E+10 | 0.287434E+10 | 0.125792E+10 | 0.00 | 0.00 |
February | 0.401654E+10 | 0.367531E+10 | 0.472728E+10 | 0.319290E+10 | 0.153439E+10 | 0.00 | 0.00 |
March | 0.379862E+10 | 0.342575E+10 | 0.461392E+10 | 0.292075E+10 | 0.169318E+10 | 0.00 | 0.00 |
April | 0.337466E+10 | 0.220527E+10 | 0.404395E+10 | 0.219520E+10 | 0.184875E+10 | 0.00 | 0.00 |
May | 0.299763E+10 | 0.131839E+10 | 0.351217E+10 | 0.120036E+10 | 0.231181E+10 | 0.00 | 0.00 |
June | 0.275486E+10 | 0.900650E+09 | 0.304972E+10 | 0.812512E+09 | 0.223721E+10 | 0.00 | 0.00 |
July | 0.330153E+10 | 0.874852E+09 | 0.344548E+10 | 0.109112E+10 | 0.235436E+10 | 0.00 | 0.00 |
August | 0.362662E+10 | 0.103641E+10 | 0.368004E+10 | 0.153925E+10 | 0.214079E+10 | 0.00 | 0.00 |
September | 0.366705E+10 | 0.155896E+10 | 0.381615E+10 | 0.203299E+10 | 0.178317E+10 | 0.00 | 0.00 |
October | 0.297031E+10 | 0.231152E+10 | 0.336717E+10 | 0.198079E+10 | 0.138638E+10 | 0.00 | 0.00 |
November | 0.235305E+10 | 0.305605E+10 | 0.290106E+10 | 0.182043E+10 | 0.108064E+10 | 0.00 | 0.00 |
December | 0.219616E+10 | 0.470255E+10 | 0.319063E+10 | 0.209181E+10 | 0.109882E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.381695E+11 | 0.299002E+11 | 0.444798E+11 | 0.237524E+11 | 0.207274E+11 | 0.00 | 0.00 |
Minimum of Months | 0.219616E+10 | 0.874852E+09 | 0.290106E+10 | 0.812512E+09 | 0.108064E+10 | 0.00 | 0.00 |
Maximum of Months | 0.401654E+10 | 0.483453E+10 | 0.472728E+10 | 0.319290E+10 | 0.235436E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.310643E+10 | 0.482513E+10 | 0.413226E+10 | 0.287434E+10 | 0.125792E+10 | 0.00 | 0.00 |
February | 0.401884E+10 | 0.365006E+10 | 0.472728E+10 | 0.319290E+10 | 0.153439E+10 | 0.00 | 0.00 |
March | 0.380928E+10 | 0.337585E+10 | 0.461392E+10 | 0.292075E+10 | 0.169318E+10 | 0.00 | 0.00 |
April | 0.339374E+10 | 0.213850E+10 | 0.404395E+10 | 0.219520E+10 | 0.184875E+10 | 0.00 | 0.00 |
May | 0.301371E+10 | 0.126155E+10 | 0.351217E+10 | 0.120036E+10 | 0.231181E+10 | 0.00 | 0.00 |
June | 0.275980E+10 | 0.857313E+09 | 0.304972E+10 | 0.812512E+09 | 0.223721E+10 | 0.00 | 0.00 |
July | 0.329558E+10 | 0.839265E+09 | 0.344548E+10 | 0.109112E+10 | 0.235436E+10 | 0.00 | 0.00 |
August | 0.362075E+10 | 0.999259E+09 | 0.368004E+10 | 0.153925E+10 | 0.214079E+10 | 0.00 | 0.00 |
September | 0.367668E+10 | 0.150197E+10 | 0.381615E+10 | 0.203299E+10 | 0.178317E+10 | 0.00 | 0.00 |
October | 0.299474E+10 | 0.222395E+10 | 0.336717E+10 | 0.198079E+10 | 0.138638E+10 | 0.00 | 0.00 |
November | 0.236431E+10 | 0.300121E+10 | 0.290106E+10 | 0.182043E+10 | 0.108064E+10 | 0.00 | 0.00 |
December | 0.219204E+10 | 0.469261E+10 | 0.319063E+10 | 0.209181E+10 | 0.109882E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.382459E+11 | 0.293667E+11 | 0.444798E+11 | 0.237524E+11 | 0.207274E+11 | 0.00 | 0.00 |
Minimum of Months | 0.219204E+10 | 0.839265E+09 | 0.290106E+10 | 0.812512E+09 | 0.108064E+10 | 0.00 | 0.00 |
Maximum of Months | 0.401884E+10 | 0.482513E+10 | 0.472728E+10 | 0.319290E+10 | 0.235436E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.616543E+09 | 0.101707E+10 | 0.850274E+09 | 0.591437E+09 | 0.258836E+09 | 0.00 | 0.00 |
February | 0.797554E+09 | 0.768314E+09 | 0.972707E+09 | 0.656985E+09 | 0.315722E+09 | 0.00 | 0.00 |
March | 0.757957E+09 | 0.718761E+09 | 0.949382E+09 | 0.600986E+09 | 0.348396E+09 | 0.00 | 0.00 |
April | 0.680134E+09 | 0.447909E+09 | 0.832101E+09 | 0.451694E+09 | 0.380406E+09 | 0.00 | 0.00 |
May | 0.610830E+09 | 0.254675E+09 | 0.722681E+09 | 0.246992E+09 | 0.475689E+09 | 0.00 | 0.00 |
June | 0.556485E+09 | 0.171251E+09 | 0.627525E+09 | 0.167186E+09 | 0.460339E+09 | 0.00 | 0.00 |
July | 0.660512E+09 | 0.172954E+09 | 0.708958E+09 | 0.224513E+09 | 0.484444E+09 | 0.00 | 0.00 |
August | 0.736712E+09 | 0.201553E+09 | 0.757222E+09 | 0.316722E+09 | 0.440500E+09 | 0.00 | 0.00 |
September | 0.749862E+09 | 0.300665E+09 | 0.785229E+09 | 0.418316E+09 | 0.366912E+09 | 0.00 | 0.00 |
October | 0.602259E+09 | 0.460409E+09 | 0.692844E+09 | 0.407576E+09 | 0.285267E+09 | 0.00 | 0.00 |
November | 0.462824E+09 | 0.638279E+09 | 0.596936E+09 | 0.374579E+09 | 0.222357E+09 | 0.00 | 0.00 |
December | 0.432906E+09 | 0.995623E+09 | 0.656519E+09 | 0.430420E+09 | 0.226098E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.766458E+10 | 0.614747E+10 | 0.915238E+10 | 0.488741E+10 | 0.426497E+10 | 0.00 | 0.00 |
Minimum of Months | 0.432906E+09 | 0.171251E+09 | 0.596936E+09 | 0.167186E+09 | 0.222357E+09 | 0.00 | 0.00 |
Maximum of Months | 0.797554E+09 | 0.101707E+10 | 0.972707E+09 | 0.656985E+09 | 0.484444E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -16.9 | -17.3 | -20.0 | 3.73 | -31.9 | 33.25 | 98.18 | 0.00 |
February | -11.6 | -12.6 | -16.7 | 4.33 | -26.7 | 48.91 | 138.70 | 0.00 |
March | -6.2 | -7.5 | -10.8 | 3.55 | -19.4 | 56.69 | 163.76 | 0.01 |
April | 3.97 | 0.48 | -4.8 | 4.72 | -9.1 | 70.41 | 207.70 | 0.01 |
May | 13.43 | 8.45 | 3.53 | 3.60 | 2.20 | 102.27 | 202.62 | 0.00 |
June | 18.03 | 14.18 | 11.55 | 3.74 | 7.84 | 104.36 | 210.60 | 0.06 |
July | 19.67 | 16.51 | 14.78 | 3.14 | 8.96 | 101.67 | 223.82 | 0.04 |
August | 17.94 | 15.19 | 13.59 | 3.45 | 8.98 | 87.39 | 175.79 | 0.04 |
September | 12.29 | 9.87 | 7.80 | 3.78 | 3.33 | 70.27 | 143.96 | 0.00 |
October | 5.42 | 3.48 | 1.07 | 3.53 | -4.7 | 51.74 | 90.11 | 0.00 |
November | -2.0 | -3.6 | -6.9 | 4.42 | -13.7 | 34.68 | 65.95 | 0.00 |
December | -14.6 | -15.1 | -18.1 | 3.91 | -28.3 | 29.58 | 68.99 | 0.00 |
Annual Sum or Average | 3.36 | 1.07 | -2.0 | 3.82 | -8.5 | 66.03 | 149.18 | 0.01 |
Minimum of Months | -16.9 | -17.3 | -20.0 | 3.14 | -31.9 | 29.58 | 65.95 | 0.00 |
Maximum of Months | 19.67 | 16.51 | 14.78 | 4.72 | 8.98 | 104.36 | 223.82 | 0.06 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.10 | 29-JAN-14:00 | -0.9 | -4.4 | 2.60 | -11.4 | 145.00 | 110.00 |
February | 8.90 | 20-FEB-15:00 | 2.85 | -6.7 | 8.80 | -9.0 | 49.00 | 646.00 |
March | 11.10 | 26-MAR-15:00 | 5.46 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 26.70 | 23-APR-15:00 | 16.93 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 29.40 | 25-MAY-17:00 | 19.24 | 13.90 | 1.50 | 16.49 | 47.50 | 582.00 |
June | 35.00 | 29-JUN-15:00 | 24.70 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 31.10 | 15-JUL-14:20 | 25.34 | 23.33 | 8.07 | 19.92 | 299.67 | 518.33 |
August | 30.60 | 08-AUG-14:00 | 23.35 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 26.10 | 01-SEP-14:00 | 17.80 | 13.30 | 3.60 | 14.28 | 112.00 | 751.50 |
October | 22.20 | 19-OCT-14:00 | 13.60 | 7.20 | 6.70 | 8.15 | 35.50 | 701.50 |
November | 18.30 | 01-NOV-14:00 | 13.43 | 10.00 | 3.10 | 11.84 | 105.00 | 30.50 |
December | 1.10 | 28-DEC-02:00 | 0.43 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.10 | -0.9 | -6.7 | 1.50 | -11.4 | 0.00 | 0.00 | |
Maximum of Months | 35.00 | 25.34 | 23.33 | 11.30 | 24.66 | 299.67 | 842.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -35.6 | 06-JAN-08:00 | -35.7 | -37.8 | 0.00 | -57.8 | 27.00 | 381.00 |
February | -33.3 | 14-FEB-06:00 | -33.4 | -36.7 | 0.00 | -55.6 | 0.00 | 0.00 |
March | -28.9 | 05-MAR-06:00 | -29.1 | -32.2 | 1.50 | -50.6 | 27.00 | 41.50 |
April | -13.9 | 05-APR-05:00 | -14.3 | -16.1 | 0.00 | -32.5 | 14.50 | 199.00 |
May | -3.9 | 01-MAY-05:00 | -6.0 | -12.2 | 0.00 | -22.4 | 35.00 | 415.00 |
June | 1.10 | 04-JUN-04:00 | 0.61 | 0.00 | 0.00 | -14.9 | 37.00 | 169.50 |
July | 6.10 | 02-JUL-04:00 | 6.10 | 6.10 | 0.00 | -8.8 | 33.50 | 204.50 |
August | 4.40 | 19-AUG-03:00 | 4.40 | 4.40 | 0.00 | -10.7 | 0.00 | 0.00 |
September | 1.10 | 06-SEP-03:00 | 1.10 | 1.10 | 0.00 | -14.7 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.6 | -12.8 | 1.50 | -28.2 | 0.00 | 0.00 |
November | -20.6 | 29-NOV-05:00 | -20.8 | -22.2 | 2.10 | -37.8 | 0.00 | 0.00 |
December | -31.1 | 24-DEC-06:19 | -31.3 | -35.1 | 3.33 | -53.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -35.6 | -35.7 | -37.8 | 0.00 | -57.8 | 0.00 | 0.00 | |
Maximum of Months | 6.10 | 6.10 | 6.10 | 3.33 | -8.8 | 37.00 | 415.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -0.4 | 16-JAN-12:00 | 0.00 | -1.1 | 5.70 | -6.6 | 172.50 | 3.00 |
February | 3.33 | 21-FEB-12:00 | 6.70 | -1.1 | 7.70 | -6.0 | 270.00 | 303.00 |
March | 5.46 | 26-MAR-15:00 | 11.10 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 16.93 | 23-APR-15:00 | 26.70 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 19.90 | 26-MAY-11:00 | 25.60 | 17.20 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 24.70 | 29-JUN-15:00 | 35.00 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 25.75 | 15-JUL-13:00 | 31.10 | 23.90 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 23.35 | 08-AUG-14:00 | 30.60 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 18.67 | 01-SEP-00:00 | 19.00 | 17.50 | 2.80 | 16.30 | 0.00 | 0.00 |
October | 13.70 | 19-OCT-13:00 | 21.70 | 7.80 | 5.70 | 7.75 | 54.50 | 739.00 |
November | 14.29 | 21-NOV-12:00 | 15.00 | 13.90 | 5.20 | 11.46 | 134.50 | 25.50 |
December | 0.43 | 28-DEC-02:00 | 1.10 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.4 | 0.00 | -1.1 | 2.80 | -6.6 | 0.00 | 0.00 | |
Maximum of Months | 25.75 | 35.00 | 23.90 | 11.30 | 24.66 | 333.00 | 842.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -1.1 | 16-JAN-11:00 | -0.6 | -0.8 | 5.70 | -7.3 | 164.50 | 5.00 |
February | -0.6 | 21-FEB-08:00 | 4.40 | 2.24 | 8.80 | -6.6 | 123.00 | 89.50 |
March | 0.00 | 29-MAR-20:00 | 1.70 | 0.95 | 1.50 | -4.8 | 0.00 | 0.00 |
April | 11.10 | 23-APR-13:00 | 24.40 | 16.06 | 10.80 | 9.72 | 98.50 | 903.50 |
May | 17.20 | 26-MAY-11:00 | 25.60 | 19.90 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 22.80 | 29-JUN-23:19 | 26.30 | 23.71 | 5.20 | 14.28 | 0.00 | 0.00 |
July | 23.90 | 15-JUL-13:00 | 31.10 | 25.75 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 20.60 | 08-AUG-14:00 | 30.60 | 23.35 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 17.92 | 01-SEP-00:10 | 19.75 | 18.15 | 3.22 | 13.22 | 0.00 | 0.00 |
October | 12.20 | 07-OCT-12:20 | 14.47 | 13.16 | 3.43 | 9.18 | 163.17 | 18.50 |
November | 13.90 | 21-NOV-12:00 | 15.00 | 14.29 | 5.20 | 11.46 | 134.50 | 25.50 |
December | -0.0 | 06-DEC-02:00 | 0.00 | -0.0 | 3.60 | -6.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -1.1 | -0.6 | -0.8 | 1.50 | -7.3 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 31.10 | 25.75 | 10.80 | 22.64 | 333.00 | 903.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 1.89 | 11.66 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 0.58 | 19.92 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 0.81 | 26.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 2.58 | 37.52 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 5.43 | 45.25 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 8.61 | 47.76 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 11.25 | 48.86 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 12.66 | 38.94 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 12.41 | 29.23 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 10.60 | 17.37 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 7.72 | 10.89 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 4.55 | 9.11 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 6.63 | 28.63 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 0.58 | 9.11 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 12.66 | 48.86 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.314388E+10 | -.270575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -438133933.8 | 58.99 | 0.00 | 0.00 |
February | 0.291474E+10 | -.252022E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -394527950.8 | 59.00 | 0.00 | 0.00 |
March | 0.328202E+10 | -.284828E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -433742353.6 | 59.00 | 0.00 | 0.00 |
April | 0.303599E+10 | -.262634E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -409654069.2 | 59.00 | 0.00 | 0.00 |
May | 0.298030E+10 | -.258142E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -398881741.8 | 58.99 | 0.00 | 0.00 |
June | 0.275899E+10 | -.238192E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -377068592.7 | 58.99 | 0.00 | 0.00 |
July | 0.264878E+10 | -.226379E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -384989896.5 | 58.99 | 0.00 | 0.00 |
August | 0.265488E+10 | -.226848E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -386395812.7 | 58.99 | 0.00 | 0.00 |
September | 0.255064E+10 | -.216891E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -381724916.4 | 58.99 | 0.00 | 0.00 |
October | 0.270853E+10 | -.229377E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -414760892.1 | 58.99 | 0.00 | 0.00 |
November | 0.275767E+10 | -.234053E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -417143505.6 | 58.99 | 0.00 | 0.00 |
December | 0.301895E+10 | -.258158E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -437365539.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.344554E+11 | -.295810E+11 | 8760.00 | -.487439E+10 | 58.99 | |||||
Minimum of Months | 0.255064E+10 | -.284828E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -438133933.8 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.328202E+10 | -.216891E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -377068592.7 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 243.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 265.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 254.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 296.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 401.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 409.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 352.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 344.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 255.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3785.50 | ||||||||||
Minimum of Months | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.360059E+11 | 52518.30 | 01-JAN-00:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.258453E+11 | 52518.30 | 01-FEB-03:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.201112E+11 | 52518.30 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.743676E+10 | 52518.30 | 01-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.629968E+09 | 52518.30 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 23176560.55 | 4723.21 | 28-SEP-05:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.309245E+10 | 52518.30 | 05-OCT-04:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.132219E+11 | 52518.30 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.322612E+11 | 52518.30 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.138628E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.360059E+11 | 52518.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.122241E+12 | 291316.88 | 01-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.811849E+11 | 291316.88 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.608167E+11 | 291316.88 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.160214E+11 | 291316.88 | 02-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.795722E+09 | 291316.88 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.830300E+10 | 291316.88 | 10-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.424729E+11 | 291316.88 | 04-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.109860E+12 | 291316.88 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.441696E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.122241E+12 | 291316.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.150974E+11 | 38019.41 | 01-JAN-02:42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.935189E+10 | 38019.41 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.680272E+10 | 38019.41 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.221568E+10 | 38019.41 | 01-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.173560E+09 | 38019.41 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 5822621.89 | 1036.49 | 23-SEP-05:34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.926064E+09 | 38019.41 | 09-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.471790E+10 | 38019.41 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.140729E+11 | 38019.41 | 01-DEC-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.533640E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.150974E+11 | 38019.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.188743E+11 | 32716.83 | 01-JAN-01:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.124124E+11 | 32716.83 | 01-FEB-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.983305E+10 | 32716.83 | 01-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.385705E+10 | 32716.83 | 01-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.456612E+09 | 32716.83 | 01-MAY-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 3969597.23 | 868.65 | 03-JUN-05:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 3577429.71 | 1286.53 | 19-AUG-05:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.112902E+09 | 10426.60 | 28-SEP-04:41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.219937E+10 | 32716.83 | 06-OCT-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.737317E+10 | 32716.83 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.178324E+11 | 32716.83 | 01-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.729589E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.188743E+11 | 32716.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.376435E+11 | 88701.84 | 05-JAN-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.243060E+11 | 75967.12 | 01-FEB-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.204370E+11 | 57403.75 | 15-MAR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.792708E+10 | 34898.74 | 04-APR-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.100925E+10 | 13435.44 | 01-MAY-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 71586392.15 | 3424.91 | 02-JUN-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 16476548.26 | 1530.17 | 08-JUL-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.105608E+09 | 6212.77 | 17-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.108319E+10 | 11352.40 | 27-SEP-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.742060E+10 | 29062.55 | 29-OCT-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.162977E+11 | 58337.84 | 25-NOV-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.356704E+11 | 85218.29 | 24-DEC-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.151988E+12 | |||||||
Minimum of Months | 16476548.26 | 1530.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.376435E+11 | 88701.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.123042E+09 | 0.117197E+09 | 4342.24 | 23-APR-16:00 | 3766.15 | 0.00 |
May | 0.00 | 0.00 | 0.478153E+10 | 0.412475E+10 | 15551.03 | 25-MAY-15:00 | 12265.84 | 0.00 |
June | 0.00 | 0.00 | 0.112039E+11 | 0.864441E+10 | 38119.92 | 30-JUN-04:01 | 18080.16 | 0.00 |
July | 0.00 | 0.00 | 0.160822E+11 | 0.119837E+11 | 37213.26 | 04-JUL-06:02 | 18923.64 | 0.00 |
August | 0.00 | 0.00 | 0.133090E+11 | 0.100188E+11 | 35920.84 | 09-AUG-04:02 | 22583.02 | 0.00 |
September | 0.00 | 0.00 | 0.461290E+10 | 0.383288E+10 | 35898.24 | 01-SEP-04:02 | 21589.02 | 0.00 |
October | 0.00 | 0.00 | 0.369347E+09 | 0.336594E+09 | 5256.21 | 21-OCT-15:50 | 4909.38 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.504820E+11 | 0.390583E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.160822E+11 | 0.119837E+11 | 38119.92 | 22583.02 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.431678E+10 | 0.420525E+10 | 45283.65 | 23-APR-16:00 | 39908.55 | 0.00 |
May | 0.00 | 0.00 | 0.365542E+11 | 0.325485E+11 | 168207.40 | 26-MAY-04:02 | 132983.33 | 0.00 |
June | 0.00 | 0.00 | 0.710999E+11 | 0.554268E+11 | 180292.90 | 30-JUN-04:01 | 109904.37 | 0.00 |
July | 0.00 | 0.00 | 0.927237E+11 | 0.684211E+11 | 178337.63 | 04-JUL-06:02 | 106521.49 | 0.00 |
August | 0.00 | 0.00 | 0.773139E+11 | 0.578125E+11 | 173561.09 | 09-AUG-04:02 | 116919.30 | 0.00 |
September | 0.00 | 0.00 | 0.297244E+11 | 0.250703E+11 | 173176.75 | 01-SEP-04:02 | 110781.50 | 0.00 |
October | 0.00 | 0.00 | 0.392783E+10 | 0.361673E+10 | 38519.86 | 19-OCT-15:00 | 34914.57 | 0.00 |
November | 0.00 | 0.00 | 0.279326E+09 | 0.224437E+09 | 18995.08 | 01-NOV-15:00 | 15194.94 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.315940E+12 | 0.247326E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.927237E+11 | 0.684211E+11 | 180292.90 | 132983.33 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 24767315.30 | 24767315.30 | 1767.84 | 28-FEB-15:10 | 1767.84 | 0.00 |
March | 0.00 | 0.00 | 64920704.26 | 64920704.26 | 2762.70 | 31-MAR-14:30 | 2762.70 | 0.00 |
April | 0.00 | 0.00 | 0.149928E+10 | 0.148751E+10 | 8350.52 | 23-APR-14:20 | 7715.07 | 0.00 |
May | 0.00 | 0.00 | 0.593134E+10 | 0.551187E+10 | 22912.87 | 26-MAY-04:02 | 18387.65 | 0.00 |
June | 0.00 | 0.00 | 0.987827E+10 | 0.816429E+10 | 25252.20 | 30-JUN-04:01 | 12893.94 | 0.00 |
July | 0.00 | 0.00 | 0.132449E+11 | 0.104951E+11 | 24592.56 | 04-JUL-06:02 | 13276.43 | 0.00 |
August | 0.00 | 0.00 | 0.121906E+11 | 0.988283E+10 | 23767.51 | 09-AUG-04:02 | 16075.81 | 0.00 |
September | 0.00 | 0.00 | 0.653421E+10 | 0.595007E+10 | 23695.96 | 01-SEP-04:02 | 15194.91 | 0.00 |
October | 0.00 | 0.00 | 0.210798E+10 | 0.204608E+10 | 11035.22 | 19-OCT-14:10 | 10517.93 | 0.00 |
November | 0.00 | 0.00 | 0.170445E+09 | 0.158052E+09 | 4048.35 | 17-NOV-13:30 | 4048.35 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.516468E+11 | 0.437854E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.132449E+11 | 0.104951E+11 | 25252.20 | 18387.65 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 17791.68 | 17791.68 | 23.21 | 31-MAR-14:50 | 23.21 | 0.00 |
April | 0.00 | 0.00 | 0.604073E+09 | 0.592516E+09 | 5900.38 | 23-APR-14:20 | 5309.88 | 0.00 |
May | 0.00 | 0.00 | 0.323824E+10 | 0.289759E+10 | 12705.69 | 26-MAY-04:02 | 9942.96 | 0.00 |
June | 0.00 | 0.00 | 0.643648E+10 | 0.505312E+10 | 21121.69 | 30-JUN-04:01 | 10158.16 | 0.00 |
July | 0.00 | 0.00 | 0.950064E+10 | 0.715286E+10 | 20595.24 | 04-JUL-06:02 | 10328.17 | 0.00 |
August | 0.00 | 0.00 | 0.835281E+10 | 0.645241E+10 | 19864.36 | 09-AUG-04:02 | 12599.52 | 0.00 |
September | 0.00 | 0.00 | 0.366436E+10 | 0.326043E+10 | 19802.62 | 01-SEP-04:02 | 11782.00 | 0.00 |
October | 0.00 | 0.00 | 0.992702E+09 | 0.954525E+09 | 8363.10 | 19-OCT-14:20 | 7825.10 | 0.00 |
November | 0.00 | 0.00 | 15614864.08 | 14906977.44 | 1245.60 | 17-NOV-13:50 | 1245.60 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.328049E+11 | 0.263784E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.950064E+10 | 0.715286E+10 | 21121.69 | 12599.52 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.180725E+11 | 0.99 | 11020.40 | 01-JAN-00:04 | 1.62 |
February | 0.156042E+11 | 0.95 | 11020.40 | 01-FEB-00:05 | 1.62 |
March | 0.162266E+11 | 0.89 | 11020.40 | 01-MAR-05:01 | 1.61 |
April | 0.133511E+11 | 0.75 | 11020.40 | 01-APR-04:01 | 1.61 |
May | 0.759062E+10 | 0.41 | 11020.40 | 01-MAY-04:01 | 1.61 |
June | 0.328884E+10 | 0.18 | 11020.40 | 01-JUN-04:02 | 1.60 |
July | 0.173342E+10 | 0.09 | 11020.40 | 01-JUL-07:05 | 1.59 |
August | 0.289896E+10 | 0.16 | 11020.40 | 01-AUG-07:05 | 1.58 |
September | 0.910299E+10 | 0.51 | 11020.40 | 01-SEP-07:05 | 1.58 |
October | 0.132640E+11 | 0.72 | 11020.40 | 01-OCT-07:03 | 1.60 |
November | 0.151853E+11 | 0.86 | 11020.40 | 01-NOV-04:01 | 1.61 |
December | 0.178768E+11 | 0.98 | 11020.40 | 01-DEC-01:35 | 1.61 |
Annual Sum or Average | 0.134195E+12 | 0.62 | |||
Minimum of Months | 0.173342E+10 | 0.09 | 11020.40 | 1.58 | |
Maximum of Months | 0.180725E+11 | 0.99 | 11020.40 | 1.62 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.336135E+10 | 0.71 | 1933.30 | 05-JAN-15:00 | 0.94 |
February | 0.300428E+10 | 0.69 | 1933.30 | 01-FEB-16:00 | 0.94 |
March | 0.327482E+10 | 0.63 | 1933.30 | 04-MAR-21:38 | 0.94 |
April | 0.308391E+10 | 0.59 | 1933.30 | 01-APR-18:00 | 0.94 |
May | 0.313153E+10 | 0.57 | 1933.30 | 01-MAY-08:15 | 0.94 |
June | 0.305281E+10 | 0.57 | 1933.30 | 01-JUN-16:40 | 0.93 |
July | 0.310954E+10 | 0.56 | 1933.30 | 06-JUL-10:40 | 0.93 |
August | 0.315558E+10 | 0.57 | 1933.30 | 01-AUG-08:18 | 0.92 |
September | 0.302808E+10 | 0.56 | 1933.30 | 04-SEP-17:52 | 0.93 |
October | 0.311999E+10 | 0.57 | 1933.30 | 02-OCT-16:20 | 0.93 |
November | 0.306723E+10 | 0.60 | 1933.30 | 01-NOV-06:50 | 0.93 |
December | 0.333887E+10 | 0.70 | 1933.30 | 01-DEC-11:30 | 0.94 |
Annual Sum or Average | 0.377280E+11 | 0.61 | |||
Minimum of Months | 0.300428E+10 | 0.56 | 1933.30 | 0.92 | |
Maximum of Months | 0.336135E+10 | 0.71 | 1933.30 | 0.94 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.241884E+11 | 1.00 | 14855.76 | 02-JAN-07:20 | 1.59 |
February | 0.218839E+11 | 1.00 | 14855.76 | 06-FEB-20:55 | 1.59 |
March | 0.244266E+11 | 1.01 | 14855.76 | 02-MAR-12:06 | 1.59 |
April | 0.233169E+11 | 0.97 | 14855.76 | 02-APR-07:50 | 1.59 |
May | 0.240467E+11 | 0.96 | 14855.76 | 02-MAY-06:00 | 1.59 |
June | 0.235163E+11 | 0.97 | 14855.76 | 06-JUN-07:10 | 1.57 |
July | 0.240440E+11 | 0.96 | 14855.76 | 03-JUL-05:50 | 1.57 |
August | 0.243798E+11 | 0.98 | 14855.76 | 03-AUG-08:20 | 1.57 |
September | 0.232847E+11 | 0.95 | 14855.76 | 08-SEP-08:41 | 1.57 |
October | 0.238112E+11 | 0.95 | 14855.76 | 01-OCT-13:40 | 1.58 |
November | 0.230766E+11 | 0.98 | 14855.76 | 03-NOV-10:09 | 1.59 |
December | 0.241899E+11 | 1.00 | 14855.76 | 06-DEC-08:30 | 1.58 |
Annual Sum or Average | 0.284165E+12 | 0.98 | |||
Minimum of Months | 0.218839E+11 | 0.95 | 14855.76 | 1.57 | |
Maximum of Months | 0.244266E+11 | 1.01 | 14855.76 | 1.59 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.232667E+10 | 0.71 | 1389.72 | 02-JAN-09:50 | 0.98 |
February | 0.208570E+10 | 0.68 | 1389.72 | 01-FEB-10:50 | 0.98 |
March | 0.230646E+10 | 0.64 | 1389.72 | 01-MAR-07:26 | 0.98 |
April | 0.219183E+10 | 0.61 | 1389.72 | 01-APR-05:47 | 0.98 |
May | 0.224929E+10 | 0.59 | 1389.72 | 01-MAY-06:00 | 0.98 |
June | 0.219653E+10 | 0.59 | 1389.72 | 01-JUN-07:20 | 0.97 |
July | 0.224509E+10 | 0.60 | 1389.72 | 01-JUL-19:30 | 0.97 |
August | 0.227785E+10 | 0.60 | 1389.72 | 01-AUG-07:03 | 0.96 |
September | 0.217815E+10 | 0.59 | 1389.72 | 01-SEP-07:13 | 0.96 |
October | 0.223246E+10 | 0.60 | 1389.72 | 01-OCT-09:38 | 0.97 |
November | 0.217572E+10 | 0.62 | 1389.72 | 01-NOV-05:27 | 0.97 |
December | 0.232462E+10 | 0.71 | 1389.72 | 01-DEC-16:50 | 0.98 |
Annual Sum or Average | 0.267904E+11 | 0.63 | |||
Minimum of Months | 0.208570E+10 | 0.59 | 1389.72 | 0.96 | |
Maximum of Months | 0.232667E+10 | 0.71 | 1389.72 | 0.98 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.190491E+10 | 0.74 | 1116.20 | 06-JAN-20:13 | 0.98 |
February | 0.170087E+10 | 0.71 | 1116.20 | 01-FEB-07:25 | 0.98 |
March | 0.186743E+10 | 0.65 | 1116.20 | 01-MAR-14:50 | 0.98 |
April | 0.176775E+10 | 0.61 | 1116.20 | 01-APR-05:20 | 0.98 |
May | 0.180692E+10 | 0.59 | 1116.20 | 01-MAY-05:46 | 0.98 |
June | 0.176268E+10 | 0.59 | 1116.20 | 01-JUN-13:00 | 0.97 |
July | 0.179722E+10 | 0.59 | 1116.20 | 01-JUL-07:01 | 0.97 |
August | 0.182407E+10 | 0.59 | 1116.20 | 01-AUG-07:20 | 0.96 |
September | 0.174884E+10 | 0.59 | 1116.20 | 01-SEP-07:00 | 0.96 |
October | 0.179767E+10 | 0.60 | 1116.20 | 01-OCT-07:38 | 0.97 |
November | 0.176075E+10 | 0.63 | 1116.20 | 01-NOV-05:31 | 0.97 |
December | 0.190111E+10 | 0.74 | 1116.20 | 01-DEC-07:14 | 0.98 |
Annual Sum or Average | 0.216402E+11 | 0.64 | |||
Minimum of Months | 0.170087E+10 | 0.59 | 1116.20 | 0.96 | |
Maximum of Months | 0.190491E+10 | 0.74 | 1116.20 | 0.98 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 3.09 | 0.00 |
February | 3.83 | 0.00 |
March | 2.86 | 0.00 |
April | 0.63 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.34 | 0.00 |
November | 2.83 | 0.00 |
December | 3.43 | 0.00 |
Annual Sum or Average | 17.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.83 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.19 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.08 | 0.00 |
May | 0.28 | 0.00 |
June | 0.08 | 0.00 |
July | 0.21 | 0.00 |
August | 0.08 | 0.00 |
September | 0.53 | 0.00 |
October | 0.28 | 0.00 |
November | 0.00 | 0.00 |
December | 0.06 | 0.00 |
Annual Sum or Average | 1.80 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.53 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.17 | 0.00 |
February | 1.46 | 0.00 |
March | 0.89 | 0.00 |
April | 0.10 | 0.00 |
May | 0.09 | 12.18 |
June | 0.36 | 0.00 |
July | 0.68 | 0.00 |
August | 0.44 | 0.00 |
September | 0.36 | 0.00 |
October | 0.12 | 0.00 |
November | 0.86 | 0.00 |
December | 2.57 | 0.00 |
Annual Sum or Average | 10.12 | 0.11 |
Minimum of Months | 0.09 | 0.00 |
Maximum of Months | 2.57 | 12.18 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.69 | 0.00 |
February | 2.22 | 0.00 |
March | 1.89 | 0.00 |
April | 0.35 | 0.00 |
May | 0.03 | 0.00 |
June | 0.00 | 0.00 |
July | 0.12 | 0.00 |
August | 0.00 | 0.00 |
September | 0.08 | 0.00 |
October | 0.41 | 0.00 |
November | 1.72 | 0.00 |
December | 3.23 | 0.00 |
Annual Sum or Average | 12.77 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 3.23 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 45.82 | 0.00 |
February | 32.60 | 0.00 |
March | 35.33 | 0.00 |
April | 62.31 | 0.00 |
May | 69.19 | 0.00 |
June | 38.98 | 0.00 |
July | 24.83 | 0.00 |
August | 45.20 | 0.00 |
September | 88.55 | 0.00 |
October | 66.47 | 0.00 |
November | 41.16 | 0.00 |
December | 37.03 | 0.00 |
Annual Sum or Average | 587.48 | 0.00 |
Minimum of Months | 24.83 | 0.00 |
Maximum of Months | 88.55 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.336135E+10 | 0.450074E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.300428E+10 | 0.323066E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.327482E+10 | 0.251390E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.312194E+10 | 0.929595E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.454927E+10 | 0.787460E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.631040E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.771571E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.694154E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.436772E+10 | 28970700.69 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.323020E+10 | 0.386556E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.306723E+10 | 0.165273E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.333887E+10 | 0.403265E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.522833E+11 | 0.173285E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.300428E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.771571E+10 | 0.450074E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.241884E+11 | 0.152802E+12 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.218839E+11 | 0.101481E+12 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.244266E+11 | 0.760209E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.247017E+11 | 0.200267E+11 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.355361E+11 | 0.994652E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.453937E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.522615E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.478556E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.325333E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.250638E+11 | 0.103787E+11 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.231671E+11 | 0.530912E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.241899E+11 | 0.137325E+12 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.381201E+12 | 0.552120E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.218839E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.522615E+11 | 0.152802E+12 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.232667E+10 | 0.188718E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.209316E+10 | 0.116899E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.232591E+10 | 0.850340E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.262284E+10 | 0.276960E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.395599E+10 | 0.216949E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.500701E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.596174E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.565164E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.400231E+10 | 7278277.36 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.282518E+10 | 0.115758E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.222606E+10 | 0.589738E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.232462E+10 | 0.175912E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.413231E+11 | 0.667050E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.209316E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.596174E+10 | 0.188718E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.190491E+10 | 0.235929E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.170087E+10 | 0.155156E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.186744E+10 | 0.122913E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.192573E+10 | 0.482131E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.265357E+10 | 0.570765E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.341914E+10 | 4961996.54 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.420206E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.390821E+10 | 4471787.14 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.266967E+10 | 0.141128E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.204698E+10 | 0.274921E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.176497E+10 | 0.921647E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.190111E+10 | 0.222905E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.299647E+11 | 0.911986E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.170087E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.420206E+10 | 0.235929E+11 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.336135E+10 | 0.00 | 0.360059E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.300428E+10 | 0.00 | 0.258453E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.327482E+10 | 0.00 | 0.201112E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.308391E+10 | 0.123042E+09 | 0.743676E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.313153E+10 | 0.478153E+10 | 0.629968E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.305281E+10 | 0.112039E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.310954E+10 | 0.160822E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.315558E+10 | 0.133090E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.302808E+10 | 0.461290E+10 | 23176560.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.311999E+10 | 0.369347E+09 | 0.309245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.306723E+10 | 0.00 | 0.132219E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.333887E+10 | 0.00 | 0.322612E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.377280E+11 | 0.504820E+11 | 0.138628E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.300428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.336135E+10 | 0.160822E+11 | 0.360059E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.241884E+11 | 0.00 | 0.122241E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.218839E+11 | 0.00 | 0.811849E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.244266E+11 | 0.00 | 0.608167E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.233169E+11 | 0.431678E+10 | 0.160214E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.240467E+11 | 0.365542E+11 | 0.795722E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.235163E+11 | 0.710999E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.240440E+11 | 0.927237E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.243798E+11 | 0.773139E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.232847E+11 | 0.297244E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.238112E+11 | 0.392783E+10 | 0.830300E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.230766E+11 | 0.279326E+09 | 0.424729E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.241899E+11 | 0.00 | 0.109860E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.284165E+12 | 0.315940E+12 | 0.441696E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.218839E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.244266E+11 | 0.927237E+11 | 0.122241E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.232667E+10 | 0.00 | 0.150974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.208570E+10 | 24767315.30 | 0.935189E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.230646E+10 | 64920704.26 | 0.680272E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.219183E+10 | 0.149928E+10 | 0.221568E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.224929E+10 | 0.593134E+10 | 0.173560E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.219653E+10 | 0.987827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.224509E+10 | 0.132449E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.227785E+10 | 0.121906E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.217815E+10 | 0.653421E+10 | 5822621.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.223246E+10 | 0.210798E+10 | 0.926064E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.217572E+10 | 0.170445E+09 | 0.471790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.232462E+10 | 0.00 | 0.140729E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.267904E+11 | 0.516468E+11 | 0.533640E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.208570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.232667E+10 | 0.132449E+11 | 0.150974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.190491E+10 | 0.00 | 0.188743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.170087E+10 | 0.00 | 0.124124E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186743E+10 | 17791.68 | 0.983305E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.176775E+10 | 0.604073E+09 | 0.385705E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.180692E+10 | 0.323824E+10 | 0.456612E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.176268E+10 | 0.643648E+10 | 3969597.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.179722E+10 | 0.950064E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.182407E+10 | 0.835281E+10 | 3577429.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.174884E+10 | 0.366436E+10 | 0.112902E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.179767E+10 | 0.992702E+09 | 0.219937E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.176075E+10 | 15614864.08 | 0.737317E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.190111E+10 | 0.00 | 0.178324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.216402E+11 | 0.328049E+11 | 0.729589E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.170087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.190491E+10 | 0.950064E+10 | 0.188743E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.336135E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450074E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.300428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323066E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.327482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.251390E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.308391E+10 | 0.00 | 0.00 | 0.00 | 38027800.09 | 0.00 | 0.929595E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.313153E+10 | 0.00 | 0.00 | 0.00 | 0.141774E+10 | 0.00 | 0.787460E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.305281E+10 | 0.00 | 0.00 | 0.00 | 0.325760E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.310954E+10 | 0.00 | 0.00 | 0.00 | 0.460617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.315558E+10 | 0.00 | 0.00 | 0.00 | 0.378596E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.302808E+10 | 0.00 | 0.00 | 0.00 | 0.133964E+10 | 0.00 | 28970700.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.311999E+10 | 0.00 | 0.00 | 0.00 | 0.110213E+09 | 0.00 | 0.386556E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.306723E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.165273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.333887E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403265E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.377280E+11 | 0.00 | 0.00 | 0.00 | 0.145554E+11 | 0.00 | 0.173285E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.300428E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.336135E+10 | 0.00 | 0.00 | 0.00 | 0.460617E+10 | 0.00 | 0.450074E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.241884E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.152802E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.218839E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101481E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.244266E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.760209E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.233169E+11 | 0.00 | 0.00 | 0.00 | 0.138473E+10 | 0.00 | 0.200267E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.240467E+11 | 0.00 | 0.00 | 0.00 | 0.114894E+11 | 0.00 | 0.994652E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.235163E+11 | 0.00 | 0.00 | 0.00 | 0.218774E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.240440E+11 | 0.00 | 0.00 | 0.00 | 0.282175E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.243798E+11 | 0.00 | 0.00 | 0.00 | 0.234758E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.232847E+11 | 0.00 | 0.00 | 0.00 | 0.924862E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.238112E+11 | 0.00 | 0.00 | 0.00 | 0.125257E+10 | 0.00 | 0.103787E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.230766E+11 | 0.00 | 0.00 | 0.00 | 90583304.88 | 0.00 | 0.530912E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.241899E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137325E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.284165E+12 | 0.00 | 0.00 | 0.00 | 0.970366E+11 | 0.00 | 0.552120E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.218839E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.244266E+11 | 0.00 | 0.00 | 0.00 | 0.282175E+11 | 0.00 | 0.152802E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.232667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188718E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.208570E+10 | 0.00 | 0.00 | 0.00 | 7461895.54 | 0.00 | 0.116899E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.230646E+10 | 0.00 | 0.00 | 0.00 | 19448528.80 | 0.00 | 0.850340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.219183E+10 | 0.00 | 0.00 | 0.00 | 0.431011E+09 | 0.00 | 0.276960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.224929E+10 | 0.00 | 0.00 | 0.00 | 0.170670E+10 | 0.00 | 0.216949E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.219653E+10 | 0.00 | 0.00 | 0.00 | 0.281048E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.224509E+10 | 0.00 | 0.00 | 0.00 | 0.371665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.227785E+10 | 0.00 | 0.00 | 0.00 | 0.337379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.217815E+10 | 0.00 | 0.00 | 0.00 | 0.182416E+10 | 0.00 | 7278277.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.223246E+10 | 0.00 | 0.00 | 0.00 | 0.592724E+09 | 0.00 | 0.115758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.217572E+10 | 0.00 | 0.00 | 0.00 | 50349177.53 | 0.00 | 0.589738E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.232462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175912E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.267904E+11 | 0.00 | 0.00 | 0.00 | 0.145328E+11 | 0.00 | 0.667050E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.208570E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.232667E+10 | 0.00 | 0.00 | 0.00 | 0.371665E+10 | 0.00 | 0.188718E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.190491E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235929E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.170087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155156E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186743E+10 | 0.00 | 0.00 | 0.00 | 4875.77 | 0.00 | 0.122913E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.176775E+10 | 0.00 | 0.00 | 0.00 | 0.157980E+09 | 0.00 | 0.482131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.180692E+10 | 0.00 | 0.00 | 0.00 | 0.846652E+09 | 0.00 | 0.570765E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.176268E+10 | 0.00 | 0.00 | 0.00 | 0.165646E+10 | 0.00 | 4961996.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.179722E+10 | 0.00 | 0.00 | 0.00 | 0.240485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.182407E+10 | 0.00 | 0.00 | 0.00 | 0.208414E+10 | 0.00 | 4471787.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.174884E+10 | 0.00 | 0.00 | 0.00 | 0.920836E+09 | 0.00 | 0.141128E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.179767E+10 | 0.00 | 0.00 | 0.00 | 0.249316E+09 | 0.00 | 0.274921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.176075E+10 | 0.00 | 0.00 | 0.00 | 4215621.66 | 0.00 | 0.921647E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.190111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.222905E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.216402E+11 | 0.00 | 0.00 | 0.00 | 0.832445E+10 | 0.00 | 0.911986E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.170087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.190491E+10 | 0.00 | 0.00 | 0.00 | 0.240485E+10 | 0.00 | 0.235929E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 2384260.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187950E+11 | 0.00 | 0.00 | 0.23 |
February | 85276833.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140962E+11 | 0.00 | 0.00 | 0.23 |
March | 0.863653E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123073E+11 | 0.00 | 0.00 | 0.23 |
April | 0.320248E+10 | 4689248.14 | 38734.99 | 166096.86 | 10009816.04 | 0.466856E+10 | 0.218033E+09 | 838.11 | 0.22 |
May | 0.231246E+10 | 0.124537E+09 | 0.00 | 5887466.41 | 0.00 | 0.394221E+09 | 0.169993E+10 | 0.00 | 0.22 |
June | 0.716671E+09 | 0.117812E+10 | 0.00 | 9459431.17 | 595563.14 | 0.00 | 0.154164E+10 | 0.00 | 0.22 |
July | 0.279769E+09 | 0.189924E+10 | 0.00 | 9245969.21 | 755568.36 | 0.00 | 0.829372E+09 | 0.00 | 0.22 |
August | 0.462922E+09 | 0.912048E+09 | 0.00 | 13899135.63 | 0.00 | 0.00 | 0.131480E+10 | 0.00 | 0.22 |
September | 0.215723E+10 | 28145261.50 | 0.00 | 12325784.13 | 0.00 | 3844872.27 | 0.285428E+10 | 0.00 | 0.22 |
October | 0.552014E+10 | 0.00 | 0.00 | 1072158.68 | 0.00 | 0.187539E+10 | 0.620662E+09 | 0.00 | 0.22 |
November | 0.219858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.840346E+10 | 0.00 | 0.00 | 0.22 |
December | 3371986.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176194E+11 | 0.00 | 0.00 | 0.23 |
Annual Sum or Average | 0.178049E+11 | 0.414678E+10 | 38734.99 | 52056042.10 | 11360947.54 | 0.781633E+11 | 0.907872E+10 | 838.11 | 0.23 |
Minimum of Months | 2384260.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.22 |
Maximum of Months | 0.552014E+10 | 0.189924E+10 | 38734.99 | 13899135.63 | 10009816.04 | 0.187950E+11 | 0.285428E+10 | 838.11 | 0.23 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.617157E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.786055E+11 | 0.00 | 0.00 | 0.43 |
February | 0.617053E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.450923E+11 | 0.00 | 0.00 | 0.43 |
March | 0.717142E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291503E+11 | 0.00 | 0.00 | 0.43 |
April | 0.478825E+11 | 0.103314E+09 | 0.00 | 14240497.27 | 0.00 | 0.741003E+10 | 0.833141E+10 | 0.00 | 0.43 |
May | 0.143996E+11 | 0.139682E+10 | 0.00 | 68141890.85 | 0.00 | 0.456847E+09 | 0.193564E+11 | 0.00 | 0.43 |
June | 0.373002E+10 | 0.100330E+11 | 0.00 | 73523553.63 | 0.00 | 0.00 | 0.122349E+11 | 0.00 | 0.44 |
July | 0.115303E+10 | 0.159254E+11 | 0.00 | 55420651.65 | 6664306.34 | 0.00 | 0.661046E+10 | 0.00 | 0.43 |
August | 0.217070E+10 | 0.768119E+10 | 0.00 | 89487830.18 | 5810552.12 | 0.00 | 0.104637E+11 | 0.00 | 0.44 |
September | 0.138740E+11 | 0.275190E+09 | 0.00 | 94970594.48 | 0.00 | 0.00 | 0.242090E+11 | 0.00 | 0.43 |
October | 0.498171E+11 | 0.00 | 0.00 | 15215202.01 | 0.00 | 0.310984E+10 | 0.937064E+10 | 0.00 | 0.42 |
November | 0.617055E+11 | 0.00 | 0.00 | 474263.95 | 0.00 | 0.198720E+11 | 0.633205E+09 | 0.00 | 0.42 |
December | 0.655416E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.667246E+11 | 0.00 | 0.00 | 0.42 |
Annual Sum or Average | 0.455409E+12 | 0.354149E+11 | 0.00 | 0.411474E+09 | 12474858.46 | 0.250422E+12 | 0.912098E+11 | 0.00 | 0.43 |
Minimum of Months | 0.115303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.717142E+11 | 0.159254E+11 | 0.00 | 94970594.48 | 6664306.34 | 0.786055E+11 | 0.242090E+11 | 0.00 | 0.44 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.441870E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.910762E+10 | 0.00 | 0.00 | 0.44 |
February | 0.499468E+10 | 0.00 | 0.00 | 266103.36 | 0.00 | 0.497232E+10 | 0.299860E+09 | 0.00 | 0.43 |
March | 0.524713E+10 | 0.00 | 0.00 | 607711.84 | 0.00 | 0.376995E+10 | 0.643247E+09 | 0.00 | 0.43 |
April | 0.348830E+10 | 11674926.73 | 0.00 | 5286265.14 | 0.00 | 0.112932E+10 | 0.142239E+10 | 0.00 | 0.43 |
May | 0.101707E+10 | 0.157854E+09 | 0.00 | 12020566.79 | 0.00 | 0.100115E+09 | 0.199233E+10 | 0.00 | 0.43 |
June | 0.357091E+09 | 0.107222E+10 | 0.00 | 10472297.06 | 0.00 | 0.00 | 0.108955E+10 | 0.00 | 0.44 |
July | 99022140.08 | 0.174791E+10 | 0.00 | 8255985.83 | 0.00 | 0.00 | 0.576930E+09 | 0.00 | 0.43 |
August | 0.127202E+09 | 0.959555E+09 | 0.00 | 13851096.38 | 0.00 | 0.00 | 0.935322E+09 | 0.00 | 0.44 |
September | 0.903354E+09 | 53039297.96 | 0.00 | 21474924.24 | 0.00 | 0.00 | 0.252909E+10 | 0.00 | 0.43 |
October | 0.332023E+10 | 0.00 | 0.00 | 9264305.64 | 0.00 | 0.518486E+09 | 0.209763E+10 | 0.00 | 0.42 |
November | 0.457586E+10 | 0.00 | 0.00 | 836839.46 | 0.00 | 0.269435E+10 | 0.604612E+09 | 0.00 | 0.43 |
December | 0.425067E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.848731E+10 | 0.00 | 0.00 | 0.44 |
Annual Sum or Average | 0.327993E+11 | 0.400226E+10 | 0.00 | 82336095.75 | 0.00 | 0.307795E+11 | 0.121910E+11 | 0.00 | 0.43 |
Minimum of Months | 99022140.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.524713E+10 | 0.174791E+10 | 0.00 | 21474924.24 | 0.00 | 0.910762E+10 | 0.252909E+10 | 0.00 | 0.44 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.180212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119903E+11 | 0.00 | 0.00 | 0.45 |
February | 0.261472E+10 | 0.00 | 0.00 | 118.03 | 0.00 | 0.776331E+10 | 4902093.73 | 0.00 | 0.44 |
March | 0.341686E+10 | 0.00 | 0.00 | 18905.78 | 0.00 | 0.619194E+10 | 32252098.54 | 0.00 | 0.44 |
April | 0.270755E+10 | 10700851.01 | 0.00 | 1779822.93 | 0.00 | 0.251030E+10 | 0.669250E+09 | 0.00 | 0.43 |
May | 0.161394E+10 | 0.136259E+09 | 0.00 | 4501895.48 | 0.00 | 0.280373E+09 | 0.114511E+10 | 0.00 | 0.43 |
June | 0.614952E+09 | 0.931975E+09 | 0.00 | 5154642.03 | 0.00 | 0.00 | 0.914379E+09 | 0.00 | 0.44 |
July | 0.274771E+09 | 0.152030E+10 | 0.00 | 5070491.25 | 0.00 | 0.00 | 0.499635E+09 | 0.00 | 0.43 |
August | 0.431013E+09 | 0.808822E+09 | 0.00 | 8104644.13 | 0.00 | 0.00 | 0.802915E+09 | 0.00 | 0.44 |
September | 0.175151E+10 | 38363244.42 | 0.00 | 11016400.44 | 0.00 | 26848454.35 | 0.166929E+10 | 0.00 | 0.43 |
October | 0.364303E+10 | 0.00 | 0.00 | 3909131.85 | 0.00 | 0.128410E+10 | 0.787441E+09 | 0.00 | 0.42 |
November | 0.314237E+10 | 0.00 | 0.00 | 72307.75 | 0.00 | 0.458805E+10 | 77384246.11 | 0.00 | 0.43 |
December | 0.137858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116007E+11 | 0.00 | 0.00 | 0.44 |
Annual Sum or Average | 0.233914E+11 | 0.344642E+10 | 0.00 | 39628359.69 | 0.00 | 0.462359E+11 | 0.660256E+10 | 0.00 | 0.43 |
Minimum of Months | 0.274771E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.364303E+10 | 0.152030E+10 | 0.00 | 11016400.44 | 0.00 | 0.119903E+11 | 0.166929E+10 | 0.00 | 0.45 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:11
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |