Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** El Paso International Ap Ut TX USA TMY3 WMO#=722700
Simulation Timestamp: 2020-06-03 19:13:04
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1462.91 | 637.71 | 637.71 |
Net Site Energy | 1462.91 | 637.71 | 637.71 |
Total Source Energy | 4380.43 | 1909.52 | 1909.52 |
Net Source Energy | 4380.43 | 1909.52 | 1909.52 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 30.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 288.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 373.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 73.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 411.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 90.32 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1341.64 | 121.27 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 30.95 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 288.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 373.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 73.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 411.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 90.32 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 194.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 305.24 | 52.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 584.85 | 52.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 194.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 305.24 | 52.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 584.85 | 52.86 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1341.641 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1341.641 | 100.00 |
Total On-Site and Utility Electric Sources | 1341.641 | 100.00 |
Total Electricity End Uses | 1341.641 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 402.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3B
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_TX_ELPASO
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13 |
RunPeriod | RUNPERIOD 1 |
Weather File | El Paso International Ap Ut TX USA TMY3 WMO#=722700 |
Latitude [deg] | 31.77 |
Longitude [deg] | -106.5 |
Elevation [m] | 1186.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 23.78 |
Skylight-Roof Ratio [%] | 1.04 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 7.7888 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 16.5511 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 16.5511 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 16.5511 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 12.6567 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 15.0797 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 15.0797 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 03-JUL-16:19 | 27-DEC-07:10 | - | - | - | 31-OCT-11:09 |
Heating | 0.00 | 102036.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 50265.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 30883.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 21078.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 4548.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 112999.56 | 106585.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 102036.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 50265.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 30883.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 21078.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 4548.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 33.55 | 0.00 | 0.00 | 0.00 |
Cooling | 914.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1182.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 231.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 1303.15 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 97.90 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4248.98 | 131.45 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 14.62 | 0.00 | 0.00 | 0.00 |
Cooling | 398.63 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 515.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 100.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 568.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 42.68 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1852.22 | 57.30 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 14.62 | 0.00 | 0.00 | 0.00 |
Cooling | 398.63 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 515.27 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 100.82 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 568.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 42.68 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1852.22 | 57.30 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 2.26 |
CORE_RETAIL DIRECT AIR | 8.66 |
POINT_OF_SALE DIRECT AIR | 1.32 |
FRONT_RETAIL DIRECT AIR | 1.03 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 1.74 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 1.74 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 35139.38 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 51528.21 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 225777.28 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 31224.97 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 25506.08 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 2.26 | 2.26 | 2.26 | 2.26 | 2.26 | 2.26 | 1.00 | 0.999532 | 2.26 |
PSZ-AC:2 | 8.66 | 8.66 | 8.66 | 8.66 | 8.80 | 8.80 | 1.00 | 0.984049 | 8.80 |
PSZ-AC:3 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.00 | 1.000000 | 1.32 |
PSZ-AC:4 | 1.03 | 1.03 | 1.03 | 1.03 | 1.04 | 1.04 | 1.00 | 0.996907 | 1.04 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 2.26 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 8.80 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.32 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 1.04 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 2.26 | 2.26 | 2.26 | 2.26 | 37349.68 | 51528.21 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 8.80 | 8.80 | 8.80 | 8.80 | 176221.11 | 225777.28 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.32 | 1.32 | 1.32 | 1.32 | 24317.67 | 31224.97 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 1.04 | 1.04 | 1.04 | 1.04 | 19722.37 | 25506.08 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 2.26 | 1.13 | 2.26 | 37349.61 | 37349.68 | 18674.84 | 37349.68 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 8.80 | 4.40 | 8.80 | 164035.96 | 176221.11 | 88110.55 | 176221.11 | 0.734832 | 0.734830 | 0.734830 | 0.734830 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.32 | 0.659215 | 1.32 | 22436.70 | 24317.67 | 12158.83 | 24317.67 | 0.760964 | 0.760960 | 0.760960 | 0.760960 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 1.04 | 0.517655 | 1.04 | 18261.94 | 19722.37 | 9861.18 | 19722.37 | 0.750480 | 0.750480 | 0.750480 | 0.750480 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 2.26 | 2414.34 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 8.80 | 16058.49 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.32 | 1459.71 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 1.04 | 1146.25 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.30 | 11.20 | 6.80 | 8.10 | 10.30 | 12.50 | 19.20 | 23.80 | 27.90 | 27.50 | 26.30 | 23.40 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | El Paso International Ap Ut TX USA TMY3 WMO#=722700 | 31.77 | -106.50 | -7.00 | 1186.00 | 87865 | 1.0443 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 17.94 | 21.10 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 7.789 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 15.859 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 16.551 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 19.781 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 16.551 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 38.071 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 16.551 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 19.781 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 12.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 12.657 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 2958.869 | 7.789 | 48.236 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2958.869 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 26489.747 | 16.551 | 102.501 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 26489.747 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2496.071 | 16.551 | 102.501 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2496.071 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2496.071 | 16.551 | 102.501 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2496.071 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 151.881 | 12.657 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 151.881 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.195 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2832 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.6890 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8365 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.472 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.284 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637443 | 3.4637443 | 3.4637443 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.1954460 | 1.1954460 | 1.1954460 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.61927053E-06 | 0.12767249E-08 | -0.37968499E-05 | 0.16832131E-17 |
21 | 2 | 0.77611055 | 0.17315568E-02 | 1.0534842 | -0.72792597E-06 |
22 | 1 | -21.915918 | 0.11588205 | -6.3286394 | 0.20197014 |
23 | 0 | 21.365777 | 0.10835518 | 5.5011278 | |
24 | 9 | -0.23694873E-14 | 0.24460372E-16 | -0.16093703E-09 | 0.40693747E-16 |
25 | 8 | 0.23448185E-07 | 0.93803824E-13 | 0.39412945E-03 | -0.26661394E-09 |
26 | 7 | -0.12728387E-01 | 0.47911758E-08 | -0.23786565E-01 | 0.14472641E-03 |
27 | 6 | 0.41857762 | 0.16585077E-05 | 0.48334039 | -0.49036802E-02 |
28 | 5 | -5.3196350 | 0.61661373E-04 | -4.5275917 | 0.64784285E-01 |
29 | 4 | 33.573705 | 0.50245725E-03 | 21.777630 | -0.42970229 |
30 | 3 | -112.44059 | 0.10912898E-02 | -56.290775 | 1.5327395 |
31 | 2 | 198.33458 | 0.61196217E-03 | 78.486619 | -2.9198277 |
32 | 1 | -171.60898 | 0.65143140E-04 | -55.433097 | 2.7533770 |
33 | 0 | 57.057407 | 0.36965150E-06 | 15.529602 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 30 | 1 | VerySmooth | 2.615 | 0.252 | 0.162 | 0.251 |
2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 31 | 1 | VerySmooth | 5.108 | 0.600 | 0.461 | 0.601 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.53892E-002 | 0.16139 | 0.61607 | 0.61607 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12001 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.46039 | 0.10300 | 0.10300 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 6.93520E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1913 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.448 | 1.180E-003 | 5.356E-004 | 0.697 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.367 | 2.293E-004 | 1.864E-004 | 0.135 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.194 | 1.288E-003 | 5.704E-004 | 0.760 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 2.497E-002 | 2.080E-003 | 6.862E-004 | 1.228 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.937 | 7.811E-002 | 2.576E-002 | 46.096 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 22899.43669 | 27479.32403 | 1.87937 | 2.25524 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 28.48000 | 6.82375E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 20041.01870 | 24049.22244 | 0.97203 | 1.16643 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -5.20000 | 2.80840E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 88165.30594 | 105798.36713 | 7.21432 | 8.65718 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 28.48000 | 6.82375E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 52532.93333 | 63039.51999 | 2.51662 | 3.01994 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -5.20000 | 2.80840E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 13268.33235 | 15921.99882 | 1.09869 | 1.31843 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 28.48000 | 6.82375E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 9990.38361 | 11988.46033 | 0.48667 | 0.58401 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -5.20000 | 2.80840E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 10436.82627 | 12524.19153 | 0.86009 | 1.03211 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 28.48000 | 6.82375E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 9987.02899 | 11984.43479 | 0.48651 | 0.58381 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -5.20000 | 2.80840E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 38.10000 | 6.82375E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 29259.37100 | 35111.24520 | 1.45017 | 1.74020 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | -5.20000 | 2.80840E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 27566.21 | 2.25629 | 2.25629 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 29713.96 | 1.16643 | 1.16643 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 124615.51 | 8.79751 | 8.79751 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 112383.42 | 3.01994 | 3.01994 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 17600.89 | 1.31843 | 1.31843 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 16555.73 | 0.58401 | 0.58401 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 14703.07 | 1.03531 | 1.03531 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 16551.73 | 0.58381 | 0.58381 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.25524 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 8.65718 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.31843 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.03211 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.74020 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 1.74020 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 35139.37904 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.25524 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.25524 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.25524 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 2.25524 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.25629 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 2.25629 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.99953 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 8.65718 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 8.65718 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 8.65718 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 8.65718 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 8.79751 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 8.79751 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.98405 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.31843 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.31843 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.31843 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.31843 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.31843 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.31843 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.03211 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.03211 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.03211 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.03211 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.03531 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 1.03531 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 0.99691 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 2.25629 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 8.79751 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.31843 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 1.03531 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.25629 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.25629 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.25629 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.25629 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.25629 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.25629 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.12815 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.25629 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 37349.61099 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 37349.68000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 18674.84000 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 37349.68000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 37349.68000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 51528.20821 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.25629 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2414.34113 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 51528.20821 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 8.79751 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 8.79751 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 8.79751 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 8.79751 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 8.79751 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 8.79751 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 4.39876 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 8.79751 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 164035.96377 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 176221.11000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 88110.55500 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 176221.11000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.73483 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.73483 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.73483 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.73483 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 176221.11000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 225777.28214 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 8.79751 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 16058.48877 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 225777.28214 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.31843 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.31843 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.31843 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.31843 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.31843 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.31843 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.65922 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.31843 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22436.69876 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 24317.67000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 12158.83500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 24317.67000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.76096 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.76096 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.76096 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.76096 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 24317.67000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 31224.96783 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.31843 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1459.70614 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 31224.96783 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.03531 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.03531 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.03531 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.03531 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.03531 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.03531 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.51766 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.03531 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 18261.94477 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 19722.37000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 9861.18500 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 19722.37000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.75048 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.75048 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.75048 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.75048 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 19722.37000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25506.07787 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.03531 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1146.25400 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25506.07787 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 35581.4 | 10.74 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 169307.2 | 12.18 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 23282.8 | 107.18 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 18909.4 | 143.63 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 1576.70 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.689 | 0.625 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.283 | 0.269 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 8 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 5.7216103541E-002 | 8.9031099345E-002 | Pass | Pass | 1.3125240026 | 11.8489581508 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 5.8339512336E-002 | 9.9899876382E-002 | Pass | Pass | 4.5031683365E-002 | 0.1293205236 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 5.0107434796E-002 | 8.4772775282E-002 | Pass | Pass | 3.1311522919E-002 | 9.4894764611E-002 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 6.1311895533E-002 | 8.1339491344E-002 | Pass | Pass | 3.4672848396E-002 | 0.1040075391 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.1463753273 | 0.4048503774 | Pass | Pass | 8.7300083766E-002 | 0.4842945661 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | -5.20 | 0.00 | -5.20 | Wetbulb [C] | 2.20 | 20.00 |
EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 38.10 | 13.00 | 18.10 | Wetbulb [C] | 3.90 | 280.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 1600.48 | 1576.70 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.625 | 0.689 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.55 | 0.273 | 0.283 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.46_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.615 | 0.252 | 0.251 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.46_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.615 | 0.252 | 0.251 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.46_SHGC_0.25 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.615 | 0.252 | 0.251 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 107.72 | 3.165 | 0.329 | 0.328 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 107.72 | 3.165 | 0.329 | 0.328 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 7.7888 | 379.89 | 2958.87 | LightsWired | BLDG_LIGHT_BACK_SCH | 63.14 | 168.00 | 62.27 | 0.0000 | Y | 34.59 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 16.5511 | 1600.48 | 26489.75 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 54.85 | 0.0000 | Y | 272.74 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 16.5511 | 150.81 | 2496.07 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 31.98 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 16.5511 | 150.81 | 2496.07 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 31.98 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 12.6567 | 12.00 | 151.88 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 1.95 |
Interior Lighting Total | 15.0797 | 2293.99 | 34592.64 | 373.23 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 26489.75 | 6622.44 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 26489.75 | 6622.44 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 4644.36 | AstronomicalClock | - | 83.77 | 83.77 | 73.03 | |
Exterior Lighting Total | 4644.36 | 73.03 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 37349.68 | 29829.70 | 7519.98 | 0.80 | 3.80 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 176221.11 | 129492.56 | 46728.55 | 0.73 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 24317.67 | 18504.77 | 5812.90 | 0.76 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 19722.37 | 14801.24 | 4921.13 | 0.75 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 35581.4 | 10.74 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 169307.2 | 12.18 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 23282.8 | 107.18 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 18909.4 | 143.63 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 35139.38 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 51528.21 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 225777.28 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 31224.97 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25506.08 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.58 | 622.50 | 1.74 | 1862.10 | 1070.05 | 1.00 | 1.32 | General | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 2.26 | 2414.34 | 1070.05 | 1.00 | 1.30 | General | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.61 | 1110.54 | 8.80 | 16058.49 | 1825.35 | 1.00 | 1.15 | General | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.32 | 1459.71 | 1107.16 | 1.00 | 1.34 | General | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.04 | 1146.25 | 1107.16 | 1.00 | 1.39 | General | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 22899.44 | 27479.32 | 72.33 | 1.879 | 2.255 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00782 | 28.48 | 0.00682 | 0.232 | 0.00 |
CORE_RETAIL | 88165.31 | 105798.37 | 66.10 | 7.214 | 8.657 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00803 | 28.48 | 0.00682 | 1.890 | 0.00 |
POINT_OF_SALE | 13268.33 | 15922.00 | 105.58 | 1.099 | 1.318 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00743 | 28.48 | 0.00682 | 0.178 | 0.00 |
FRONT_RETAIL | 10436.83 | 12524.19 | 83.05 | 0.860 | 1.032 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00765 | 28.48 | 0.00682 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 36.88 | 100.00 | 0.00001 | 38.10 | 0.00682 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 20041.02 | 24049.22 | 63.31 | 0.972 | 1.166 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00749 | -5.20 | 0.00281 | 0.232 | 0.00 |
CORE_RETAIL | 52532.93 | 63039.52 | 39.39 | 2.517 | 3.020 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00765 | -5.20 | 0.00281 | 1.890 | 0.00 |
POINT_OF_SALE | 9990.38 | 11988.46 | 79.49 | 0.487 | 0.584 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00772 | -5.20 | 0.00281 | 0.178 | 0.00 |
FRONT_RETAIL | 9987.03 | 11984.43 | 79.47 | 0.487 | 0.584 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.11 | 21.11 | 0.00772 | -5.20 | 0.00281 | 0.178 | 0.00 |
FRONT_ENTRY | 29259.37 | 35111.25 | 2925.94 | 1.450 | 1.740 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | 21.11 | 21.04 | 0.00585 | -5.20 | 0.00281 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 2.26 | 2.26 | 1.17 | 1.17 | 2.2563 | 2.2552 | 2.2563 | 0.9995 | 1.0000 |
PSZ-AC:2 | 8.80 | 8.80 | 3.02 | 3.02 | 8.7975 | 8.6572 | 8.7975 | 0.9840 | 1.0000 |
PSZ-AC:3 | 1.32 | 1.32 | 0.58 | 0.58 | 1.3184 | 1.3184 | 1.3184 | 1.0000 | 1.0000 |
PSZ-AC:4 | 1.04 | 1.04 | 0.58 | 0.58 | 1.0353 | 1.0321 | 1.0353 | 0.9969 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 35139.379 | 35139.379 | -999.0 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | 35139.38 | 35139.38 | 1.740200 | 20.82 | 11.39 | 0.00582812 | 40.00 | 19.50 | 0.00800000 | -5.20 | 0.00280840 | -5.20 | 0.0000 | 21.04 | 0.00585291 | 32.8498 | 35111.25 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 37349.680 | 0.000 | 2.256290 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 37349.68 | 34239.04 | 2.256290 | 24.44 | 14.35 | 0.00764629 | 12.80 | 9.32 | 0.00700000 | 29.30 | 0.00682375 | 15.32 | 10.2632 | 23.89 | 0.00782324 | 36.8126 | 22899.44 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 51528.208 | 51528.208 | -999.0 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 51528.21 | 51528.21 | 2.256294 | 15.73 | 10.08 | 0.00656205 | 40.00 | 19.50 | 0.00800000 | -5.20 | 0.00280840 | -5.20 | 10.2631 | 21.11 | 0.00749183 | 41.7587 | 20041.02 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 176221.110 | 0.000 | 8.797510 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 176221.11 | 166063.26 | 8.797510 | 27.13 | 15.14 | 0.00749986 | 12.80 | 9.32 | 0.00700000 | 38.10 | 0.00682375 | 18.10 | 21.4858 | 23.89 | 0.00803386 | 37.7932 | 81392.45 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 225777.282 | 225777.282 | -999.0 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 225777.28 | 225777.28 | 8.797508 | 4.54 | 2.78 | 0.00461896 | 40.00 | 19.50 | 0.00800000 | -5.20 | 0.00280840 | -5.20 | 21.4858 | 21.11 | 0.00764830 | 42.6177 | 52532.93 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 24317.670 | 0.000 | 1.318430 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24317.67 | 23291.68 | 1.318430 | 25.86 | 14.58 | 0.00733795 | 12.80 | 9.32 | 0.00700000 | 38.10 | 0.00682375 | 18.10 | 13.5093 | 23.89 | 0.00743174 | 34.9895 | 12614.82 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 31224.968 | 31224.968 | -999.0 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 31224.97 | 31224.97 | 1.318425 | 12.99 | 8.60 | 0.00622220 | 40.00 | 19.50 | 0.00800000 | -5.20 | 0.00280840 | -5.20 | 13.5093 | 21.11 | 0.00772021 | 43.0145 | 9990.38 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 19722.370 | 0.000 | 1.035310 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 19722.37 | 18765.53 | 1.035310 | 26.33 | 14.79 | 0.00740071 | 12.80 | 9.32 | 0.00700000 | 38.10 | 0.00682375 | 18.10 | 17.2036 | 23.89 | 0.00765152 | 36.0134 | 10168.74 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 25506.078 | 25506.078 | -999.0 | -999.0 | -999.000 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 25506.08 | 25506.08 | 1.035311 | 12.98 | 8.60 | 0.00622146 | 40.00 | 19.50 | 0.00800000 | -5.20 | 0.00280840 | -5.20 | 17.2036 | 21.11 | 0.00771988 | 43.0127 | 9987.03 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 35139.379 | 35139.379 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0443 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 1.740200 | 1.81734568 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | unknown | unknown | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 13:00:00 | 35139.38 | 35139.38 | 1.0000 | 1.81734568 | 1.740200 | 20.82 | 11.39 | 0.00582812 | 35726.7 | 40.00 | 19.50 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 35139.38 | -5.20 | 0.00280840 | -5.20 | 0.00000000 | 0.0000 | 21.05 | 0.00585291 | 21.04 | 0.00585291 | 32.8498 | 35111.25 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 37349.680 | 0.000 | 2.256290 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.0541 | 1004.8586 | 1.0443 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 37349.68 | 34239.04 | 1.0000 | 2.35631524 | 2.256290 | 24.44 | 14.35 | 0.00764629 | 44030.9 | 12.80 | 9.32 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 37349.68 | 29.30 | 0.00682375 | 15.32 | 0.23156651 | 10.2632 | 23.89 | 0.00774036 | 23.89 | 0.00782324 | 36.8126 | 22899.44 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 51528.208 | 51528.208 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0443 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 2.256294 | 2.35631931 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 51528.21 | 51528.21 | 1.0000 | 2.35631931 | 2.256294 | 15.73 | 10.08 | 0.00656205 | 32404.3 | 40.00 | 19.50 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 51528.21 | -5.20 | 0.00280840 | -5.20 | 0.23156651 | 10.2631 | 20.91 | 0.00749183 | 21.11 | 0.00749183 | 41.7587 | 20041.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 176221.110 | 0.000 | 8.797510 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.7819 | 1004.8586 | 1.0443 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 176221.11 | 166063.26 | 1.0000 | 9.18751885 | 8.797510 | 27.13 | 15.14 | 0.00749986 | 46395.7 | 12.80 | 9.32 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 176221.11 | 38.10 | 0.00682375 | 18.10 | 1.89021192 | 21.4858 | 23.89 | 0.00769964 | 23.89 | 0.00803386 | 37.7932 | 81392.45 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 225777.282 | 225777.282 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0443 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 8.797508 | 9.18751680 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 225777.28 | 225777.28 | 1.0000 | 9.18751680 | 8.797508 | 4.54 | 2.78 | 0.00461896 | 16150.9 | 40.00 | 19.50 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 225777.28 | -5.20 | 0.00280840 | -5.20 | 1.89021192 | 21.4858 | 20.83 | 0.00764830 | 21.11 | 0.00764830 | 42.6177 | 52532.93 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 24317.670 | 0.000 | 1.318430 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.4809 | 1004.8586 | 1.0443 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24317.67 | 23291.68 | 1.0000 | 1.37687829 | 1.318430 | 25.86 | 14.58 | 0.00733795 | 44688.6 | 12.80 | 9.32 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24317.67 | 38.10 | 0.00682375 | 18.10 | 0.17811053 | 13.5093 | 23.89 | 0.00742074 | 23.89 | 0.00743174 | 34.9895 | 12614.82 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 31224.968 | 31224.968 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0443 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.318425 | 1.37687342 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 31224.97 | 31224.97 | 1.0000 | 1.37687342 | 1.318425 | 12.99 | 8.60 | 0.00622220 | 28760.6 | 40.00 | 19.50 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 31224.97 | -5.20 | 0.00280840 | -5.20 | 0.17811053 | 13.5093 | 20.97 | 0.00772021 | 21.11 | 0.00772021 | 43.0145 | 9990.38 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 19722.370 | 0.000 | 1.035310 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1018.5975 | 1004.8586 | 1.0443 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | EL PASO INTERNATIONAL AP UT ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | 19722.37 | 18765.53 | 1.0000 | 1.08120709 | 1.035310 | 26.33 | 14.79 | 0.00740071 | 45331.4 | 12.80 | 9.32 | 0.00700000 | 30535.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 19722.37 | 38.10 | 0.00682375 | 18.10 | 0.17811053 | 17.2036 | 23.89 | 0.00752059 | 23.89 | 0.00765152 | 36.0134 | 10168.74 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25506.078 | 25506.078 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.0443 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.035311 | 1.08120849 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | EL PASO INTERNATIONAL AP UT ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 25506.08 | 25506.08 | 1.0000 | 1.08120849 | 1.035311 | 12.98 | 8.60 | 0.00622146 | 28755.9 | 40.00 | 19.50 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25506.08 | -5.20 | 0.00280840 | -5.20 | 0.17811053 | 17.2036 | 20.97 | 0.00771988 | 21.11 | 0.00771988 | 43.0127 | 9987.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC:1_OA_CONTROLLER | DifferentialDryBulb | 0.23 | 2.26 | - | |||
PSZ-AC:2_OA_CONTROLLER | DifferentialDryBulb | 1.89 | 8.80 | - | |||
PSZ-AC:3_OA_CONTROLLER | DifferentialDryBulb | 0.18 | 1.32 | - | |||
PSZ-AC:4_OA_CONTROLLER | DifferentialDryBulb | 0.18 | 1.04 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2033.00 | 2668.50 | 395.50 |
CORE_RETAIL | 2094.50 | 2112.67 | 120.67 |
POINT_OF_SALE | 2275.67 | 1601.00 | 137.17 |
FRONT_RETAIL | 2147.00 | 2059.33 | 218.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 2522.17 | 2678.33 | 402.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 0.00 | 0.00 | 0.00 | 0.00 |
FRONT_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | 0.83 | 0.00 | 0.00 | 0.00 |
Facility | 0.83 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.44 | 61.34 | 2317.33 | 0.780 | 0.048 | 0.000 | 0.000 |
CORE_RETAIL | 128.26 | 258.43 | 9762.95 | 1.143 | 0.009 | 0.000 | 0.000 |
POINT_OF_SALE | 12.09 | 24.35 | 919.94 | 1.654 | 0.053 | 0.000 | 0.000 |
FRONT_RETAIL | 12.09 | 24.35 | 919.94 | 1.260 | 0.053 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.44 | 61.34 | 2317.33 | 0.356 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.26 | 258.43 | 9762.95 | 0.690 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.09 | 24.35 | 919.94 | 0.691 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.09 | 24.35 | 919.94 | 0.690 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
Electricity:Building | 568.39 | 3083.31 | 09-APR-08:00 | 41654.89 | 02-JAN-09:10 |
Electricity:Zone:BACK_SPACE | 84.58 | 607.80 | 01-JAN-00:10 | 5172.60 | 02-JAN-09:10 |
InteriorLights:Electricity | 373.23 | 1288.14 | 09-APR-08:00 | 30883.85 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:BACK_SPACE | 34.59 | 147.94 | 01-JAN-00:10 | 2413.46 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 373.23 | 1288.14 | 09-APR-08:00 | 30883.85 | 02-JAN-09:10 |
Electricity:Zone:CORE_RETAIL | 357.04 | 1658.43 | 09-APR-08:00 | 28493.38 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 272.74 | 882.99 | 09-APR-08:00 | 23840.77 | 02-JAN-09:10 |
Electricity:Zone:POINT_OF_SALE | 84.90 | 611.62 | 01-JAN-00:10 | 5167.35 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 31.98 | 124.80 | 01-JAN-00:10 | 2246.46 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 39.92 | 197.87 | 01-JAN-00:10 | 2684.87 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 31.98 | 124.80 | 01-JAN-00:10 | 2246.46 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 1.95 | 7.59 | 01-JAN-00:10 | 136.69 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 1.95 | 7.59 | 01-JAN-00:10 | 136.69 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
ElectricityPurchased:Plant | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
Cogeneration:ElectricityPurchased | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
ElectricityNet:Plant | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
Cogeneration:ElectricityNet | 1341.64 | 3304.06 | 09-APR-06:50 | 112999.56 | 03-JUL-16:20 |
Electricity:HVAC | 700.22 | 0.00 | 01-JAN-00:10 | 76810.44 | 26-JUL-14:10 |
Fans:Electricity | 411.48 | 0.00 | 01-JAN-00:10 | 22940.89 | 05-JAN-12:10 |
General:Fans:Electricity | 411.48 | 0.00 | 01-JAN-00:10 | 22940.89 | 05-JAN-12:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 288.74 | 0.00 | 01-JAN-00:10 | 55731.65 | 26-JUL-14:10 |
ExteriorLights:Electricity | 73.03 | 0.00 | 01-JAN-07:20 | 4644.36 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 73.03 | 0.00 | 01-JAN-07:20 | 4644.36 | 01-JAN-00:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 121.27 | 1862.00 | 11-FEB-11:00 | 106585.66 | 27-DEC-07:10 |
Gas:Plant | 90.32 | 1862.00 | 11-FEB-11:00 | 5020.20 | 27-JAN-12:10 |
WaterSystems:Gas | 90.32 | 1862.00 | 11-FEB-11:00 | 5020.20 | 27-JAN-12:10 |
Water Heater:WaterSystems:Gas | 90.32 | 1862.00 | 11-FEB-11:00 | 5020.20 | 27-JAN-12:10 |
Gas:HVAC | 30.95 | 0.00 | 01-JAN-00:10 | 102036.76 | 27-DEC-07:10 |
Heating:Gas | 30.95 | 0.00 | 01-JAN-00:10 | 102036.76 | 27-DEC-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 31-OCT-11:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1760.88 | 0.00 | 01-JAN-00:10 | 263645.99 | 26-JUL-14:10 |
EnergyTransfer:Building | 792.50 | 0.00 | 01-JAN-00:10 | 94735.57 | 26-JUL-14:20 |
EnergyTransfer:Zone:BACK_SPACE | 99.45 | 0.00 | 01-JAN-00:10 | 16907.40 | 03-JUL-06:10 |
Heating:EnergyTransfer | 43.61 | 0.00 | 01-JAN-00:10 | 48508.65 | 27-DEC-06:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 4.43 | 0.00 | 01-JAN-00:10 | 15104.17 | 28-JAN-06:10 |
Cooling:EnergyTransfer | 748.90 | 0.00 | 01-JAN-00:10 | 94735.57 | 26-JUL-14:20 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 95.02 | 0.00 | 01-JAN-00:10 | 16217.07 | 03-JUL-06:10 |
EnergyTransfer:Zone:CORE_RETAIL | 509.81 | 0.00 | 01-JAN-00:10 | 65149.99 | 08-AUG-06:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 12.32 | 0.00 | 01-JAN-00:10 | 20137.55 | 27-DEC-06:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 497.50 | 0.00 | 01-JAN-00:10 | 61617.34 | 26-JUL-14:10 |
EnergyTransfer:Zone:POINT_OF_SALE | 94.76 | 0.00 | 01-JAN-00:10 | 11328.54 | 05-OCT-14:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 1.13 | 0.00 | 01-JAN-00:10 | 5538.85 | 27-DEC-06:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 93.63 | 0.00 | 01-JAN-00:10 | 11328.54 | 05-OCT-14:10 |
EnergyTransfer:Zone:FRONT_RETAIL | 64.12 | 0.00 | 01-JAN-00:10 | 9188.03 | 05-OCT-14:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 1.37 | 0.00 | 01-JAN-00:10 | 7400.04 | 27-DEC-06:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 62.75 | 0.00 | 01-JAN-00:10 | 9188.03 | 05-OCT-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 24.36 | 0.00 | 01-JAN-00:10 | 21130.44 | 26-DEC-12:10 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 24.36 | 0.00 | 01-JAN-00:10 | 21130.44 | 26-DEC-12:10 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 968.38 | 0.00 | 01-JAN-00:10 | 168920.62 | 26-JUL-14:10 |
HeatingCoils:EnergyTransfer | 24.76 | 0.00 | 01-JAN-00:10 | 81629.41 | 27-DEC-07:10 |
CoolingCoils:EnergyTransfer | 943.62 | 0.00 | 01-JAN-00:10 | 168920.62 | 26-JUL-14:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 4.426 | -95.023 | 0.000 | 0.000 | 37.436 | 34.587 | 49.992 | 0.000 | 0.000 | 1.687 | 0.003 | 0.000 | 0.000 | 0.000 | -13.573 | -19.532 |
CORE_RETAIL | 0.000 | 0.000 | 12.317 | -497.488 | 0.000 | 0.000 | 156.189 | 272.740 | 84.299 | 92.303 | 0.000 | 1.389 | 0.004 | 0.000 | -23.791 | 0.000 | -12.417 | -85.540 |
POINT_OF_SALE | 0.000 | 0.000 | 1.130 | -93.628 | 0.000 | 0.000 | 14.626 | 31.980 | 52.922 | 33.894 | 0.000 | 0.681 | 0.001 | 0.000 | -16.024 | 0.000 | -6.564 | -19.018 |
FRONT_RETAIL | 0.000 | 0.000 | 1.369 | -62.747 | 0.000 | 0.000 | 14.766 | 31.980 | 7.943 | 33.959 | 0.000 | 0.714 | 0.004 | 0.000 | -15.351 | 0.000 | -6.133 | -6.501 |
FRONT_ENTRY | 24.362 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.946 | 0.000 | 6.612 | 0.000 | 1.558 | 0.000 | 0.000 | -3.138 | 0.000 | -29.653 | -1.687 |
Total Facility | 24.362 | 0.000 | 19.243 | -748.886 | 0.000 | 0.000 | 223.017 | 373.234 | 195.156 | 166.767 | 0.000 | 6.028 | 0.012 | 0.000 | -58.303 | 0.000 | -68.341 | -132.278 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 12-MAY-06:02 | 0.00 | 0.00 | 0.00 | -50008.02 | 0.00 | 0.00 | 383.29 | 536.32 | 1226.28 | 0.00 | 0.00 | 0.00 | 48048.36 | 0.00 | -0.00 | 0.00 | -186.24 | 0.00 |
CORE_RETAIL | 15-APR-06:02 | 0.00 | 0.00 | 0.00 | -247020.02 | 0.00 | 0.00 | 1595.94 | 2648.97 | 1550.87 | 0.00 | 0.00 | 0.00 | 242793.58 | 0.00 | -1248.58 | 0.00 | -320.77 | 0.00 |
POINT_OF_SALE | 12-SEP-06:02 | 0.00 | 0.00 | 0.00 | -25416.02 | 0.00 | 0.00 | 150.36 | 499.21 | 1298.17 | 0.00 | 0.00 | 0.00 | 24397.33 | 0.00 | -919.78 | 0.00 | -9.27 | 0.00 |
FRONT_RETAIL | 30-SEP-06:02 | 0.00 | 0.00 | 0.00 | -24135.29 | 0.00 | 0.00 | 150.41 | 249.61 | 146.13 | 0.00 | 0.00 | 0.00 | 25013.68 | 0.00 | -1356.66 | 0.00 | -67.88 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 30-SEP-06:02 | 0.00 | 0.00 | 0.00 | -312431.01 | 0.00 | 0.00 | 2286.02 | 3431.54 | 3590.35 | 0.00 | 0.00 | 0.00 | 308349.64 | 0.00 | -4794.88 | 0.00 | -431.65 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 27-DEC-06:01 | 0.00 | 0.00 | 51697.72 | 0.00 | 0.00 | 0.00 | 0.00 | 147.94 | 613.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -491.65 | -51967.15 |
CORE_RETAIL | 27-DEC-06:01 | 0.00 | 0.00 | 50145.97 | 0.00 | 0.00 | 0.00 | 0.00 | 1324.49 | 1033.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2542.19 | 0.00 | -423.17 | -49539.01 |
POINT_OF_SALE | 27-DEC-06:01 | 0.00 | 0.00 | 30737.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.80 | 649.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1882.02 | 0.00 | -222.03 | -29406.84 |
FRONT_RETAIL | 27-DEC-06:01 | 0.00 | 0.00 | 25392.12 | 0.00 | 0.00 | 0.00 | 0.00 | 124.80 | 97.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1819.14 | 0.00 | -210.72 | -23584.49 |
FRONT_ENTRY | 26-DEC-12:10 | 21128.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.69 | 0.00 | 424.04 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -21128.12 | -561.22 |
Total Facility | 27-DEC-06:01 | 1841.28 | 0.00 | 157972.81 | 0.00 | 0.00 | 0.00 | 0.00 | 1729.63 | 2393.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -6620.25 | 0.00 | -1375.28 | -155941.76 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.2552 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.2563 | 0.1026 | 1.0000 | 0.2316 | 0.1026 | ||
PSZ-AC:2 | 8.6572 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 8.7975 | 0.2149 | 1.0000 | 1.8902 | 0.2149 | ||
PSZ-AC:3 | 1.3184 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.3184 | 0.1351 | 1.0000 | 0.1781 | 0.1351 | ||
PSZ-AC:4 | 1.0321 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0353 | 0.1720 | 1.0000 | 0.1781 | 0.1720 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 2.2552 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 2.2552 | 1.0000 | 1.0000 | 0.2316 | 0.1027 | ||
PSZ-AC:2 | 8.6572 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 8.6572 | 1.0000 | 1.0000 | 1.8902 | 0.2183 | ||
PSZ-AC:3 | 1.3184 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.3184 | 1.0000 | 1.0000 | 0.1781 | 0.1351 | ||
PSZ-AC:4 | 1.0321 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.0321 | 1.0000 | 1.0000 | 0.1781 | 0.1726 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.2552 | 2.2552 | 2.2552 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 8.6572 | 8.6572 | 8.6572 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.3184 | 1.3184 | 1.3184 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0321 | 1.0321 | 1.0321 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.2552 | 2.2563 | 2.2552 | 2.2552 | 0.2316 | 1.0000 |
PSZ-AC:2 | 8.6572 | 8.7975 | 8.6572 | 8.6572 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.3184 | 1.3184 | 1.3184 | 1.3184 | 0.1781 | 1.0000 |
PSZ-AC:4 | 1.0321 | 1.0353 | 1.0321 | 1.0321 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 2.2552 | 2.2552 | 2.2552 | 0.2316 | 0.1985 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 8.6572 | 8.6572 | 8.6572 | 1.8902 | 0.6259 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.3184 | 1.3184 | 1.3184 | 0.1781 | 0.3050 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 1.0321 | 1.0321 | 1.0321 | 0.1781 | 0.3051 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 2.2552 | 2.2552 | 2.2552 | 2.2552 | 0.2316 | 1.0000 |
PSZ-AC:2 | 8.6572 | 8.6572 | 8.6572 | 8.6572 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.3184 | 1.3184 | 1.3184 | 1.3184 | 0.1781 | 1.0000 |
PSZ-AC:4 | 1.0321 | 1.0321 | 1.0321 | 1.0321 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:04
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** El Paso International Ap Ut TX USA TMY3 WMO#=722700 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 30.95 | 102036.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 288.74 | 55731.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 373.23 | 30883.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 73.03 | 4644.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 411.48 | 22940.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 90.32 | 5020.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 1341.64 |
Natural Gas | 0.00 | 121.27 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 1462.91 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 162.70 |
Space Heating | 0.00 |
Space Cooling | 125.87 |
Fans (All) | 179.37 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 584.85 |
Subtotal | 584.85 |
Natural Gas [MJ/m2] | |
Space Heating | 13.49 |
Service Water Heating | 39.37 |
Miscellaneous (All) | 52.86 |
Subtotal | 52.86 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 25.51 |
Space Heating | 2.12 |
Space Cooling | 19.74 |
Fans (All) | 28.13 |
Service Water Heating | 6.17 |
Receptacle Equipment | 13.34 |
Miscellaneous | 4.99 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3292. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3B
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_TX_ELPASO
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.853941E+10 |
February | 0.000 | 0.464529E+10 |
March | 0.000 | 0.231441E+10 |
April | 0.000 | 0.287937E+09 |
May | 0.000 | 0.000 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 78153.848 |
October | 0.000 | 0.251462E+09 |
November | 0.000 | 0.290244E+10 |
December | 0.000 | 0.120087E+11 |
Annual Sum or Average | 0.309498E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.120087E+11 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.783981E+09 | 4202.47 | 27-JAN-07:07 | -4.3 | -7.3 | 0.195439E+10 | 2451.25 | 02-JAN-15:09 | 17.80 | 9.27 |
February | 0.960283E+09 | 4620.35 | 03-FEB-07:05 | -5.1 | -7.1 | 0.185859E+10 | 2451.26 | 04-FEB-15:09 | 18.40 | 7.53 |
March | 0.220850E+10 | 5634.65 | 16-MAR-15:00 | 22.80 | 8.68 | 0.220167E+10 | 2451.25 | 03-MAR-15:09 | 22.30 | 9.41 |
April | 0.657682E+10 | 38705.22 | 29-APR-06:02 | 17.48 | 12.04 | 0.214974E+10 | 2451.33 | 29-APR-10:30 | 24.75 | 14.54 |
May | 0.115703E+11 | 50009.01 | 12-MAY-06:02 | 12.77 | 6.98 | 0.223322E+10 | 2451.32 | 27-MAY-10:09 | 25.97 | 14.97 |
June | 0.155223E+11 | 44363.20 | 13-JUN-06:02 | 17.03 | 5.98 | 0.220255E+10 | 2451.40 | 03-JUN-10:09 | 30.28 | 18.19 |
July | 0.163097E+11 | 32825.59 | 03-JUL-05:01 | 27.62 | 17.60 | 0.218823E+10 | 2451.50 | 08-JUL-14:39 | 22.80 | 19.37 |
August | 0.156671E+11 | 39392.55 | 23-AUG-06:02 | 20.28 | 12.06 | 0.228198E+10 | 2451.34 | 09-AUG-14:09 | 32.30 | 18.79 |
September | 0.131161E+11 | 48492.56 | 30-SEP-06:02 | 8.95 | 6.14 | 0.215724E+10 | 2451.39 | 23-SEP-15:50 | 20.88 | 18.63 |
October | 0.840992E+10 | 41958.03 | 20-OCT-06:02 | 11.28 | 7.37 | 0.218343E+10 | 2451.30 | 28-OCT-15:00 | 23.90 | 13.82 |
November | 0.296432E+10 | 9246.25 | 10-NOV-07:02 | 17.30 | 10.93 | 0.203387E+10 | 2451.24 | 25-NOV-11:00 | 10.60 | 5.48 |
December | 0.934609E+09 | 4324.64 | 27-DEC-07:05 | -4.3 | -5.0 | 0.193678E+10 | 2451.25 | 23-DEC-14:00 | 18.30 | 6.98 |
Annual Sum or Average | 0.950239E+11 | 0.253817E+11 | ||||||||
Minimum of Months | 0.783981E+09 | 4202.47 | -5.1 | -7.3 | 0.185859E+10 | 2451.24 | 10.60 | 5.48 | ||
Maximum of Months | 0.163097E+11 | 50009.01 | 27.62 | 17.60 | 0.228198E+10 | 2451.50 | 32.30 | 19.37 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.186214E+11 | 34777.67 | 14-JAN-07:03 | 8.80 | 2.51 | 0.872483E+10 | 10326.95 | 28-JAN-15:20 | 12.57 | 5.17 |
February | 0.194865E+11 | 125104.98 | 08-FEB-07:03 | 10.68 | 6.51 | 0.815877E+10 | 10327.15 | 11-FEB-11:09 | 13.53 | 5.24 |
March | 0.278033E+11 | 227833.86 | 10-MAR-07:02 | 10.28 | 3.07 | 0.946508E+10 | 10327.08 | 25-MAR-10:09 | 16.28 | 7.83 |
April | 0.417617E+11 | 247052.04 | 15-APR-06:02 | 8.45 | 0.93 | 0.907612E+10 | 10327.24 | 29-APR-13:09 | 28.17 | 15.27 |
May | 0.548936E+11 | 234082.56 | 06-MAY-06:02 | 10.55 | 2.51 | 0.940919E+10 | 10327.34 | 27-MAY-15:00 | 30.00 | 16.45 |
June | 0.644307E+11 | 194935.07 | 13-JUN-06:02 | 17.03 | 5.98 | 0.927915E+10 | 10327.44 | 20-JUN-14:09 | 33.68 | 18.26 |
July | 0.644015E+11 | 148387.46 | 03-JUL-05:01 | 27.62 | 17.60 | 0.921888E+10 | 10328.03 | 08-JUL-14:39 | 22.80 | 19.37 |
August | 0.627572E+11 | 165929.67 | 23-AUG-06:02 | 20.28 | 12.06 | 0.961386E+10 | 10327.24 | 11-AUG-14:09 | 34.50 | 18.57 |
September | 0.545540E+11 | 215572.49 | 30-SEP-06:02 | 8.95 | 6.14 | 0.908836E+10 | 10327.72 | 23-SEP-15:50 | 20.88 | 18.63 |
October | 0.430339E+11 | 220550.44 | 24-OCT-06:02 | 9.40 | 5.32 | 0.920146E+10 | 10327.33 | 06-OCT-14:20 | 17.03 | 12.15 |
November | 0.271691E+11 | 215935.07 | 04-NOV-06:02 | 8.30 | 5.45 | 0.867849E+10 | 10327.14 | 25-NOV-11:30 | 9.75 | 5.10 |
December | 0.185822E+11 | 31851.28 | 22-DEC-07:03 | -3.0 | -4.7 | 0.854768E+10 | 10327.09 | 23-DEC-12:09 | 13.58 | 4.85 |
Annual Sum or Average | 0.497495E+12 | 0.108462E+12 | ||||||||
Minimum of Months | 0.185822E+11 | 31851.28 | -3.0 | -4.7 | 0.815877E+10 | 10326.95 | 9.75 | 4.85 | ||
Maximum of Months | 0.644307E+11 | 247052.04 | 27.62 | 17.60 | 0.961386E+10 | 10328.03 | 34.50 | 19.37 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.479103E+10 | 7809.11 | 12-JAN-15:10 | 18.90 | 10.02 | 0.849765E+09 | 973.11 | 14-JAN-12:20 | 8.90 | 7.23 |
February | 0.447365E+10 | 7577.29 | 22-FEB-13:30 | 21.15 | 7.67 | 0.779953E+09 | 973.10 | 23-FEB-15:00 | 18.90 | 7.08 |
March | 0.515773E+10 | 11004.19 | 16-MAR-06:02 | 6.47 | 1.45 | 0.894667E+09 | 973.10 | 25-MAR-10:09 | 16.28 | 7.83 |
April | 0.666056E+10 | 24258.69 | 28-APR-06:02 | 13.77 | 8.61 | 0.854546E+09 | 973.17 | 29-APR-10:39 | 25.03 | 14.58 |
May | 0.844945E+10 | 24429.70 | 11-MAY-06:02 | 19.78 | 8.33 | 0.886578E+09 | 973.17 | 18-MAY-14:30 | 31.15 | 17.61 |
June | 0.101815E+11 | 25091.73 | 01-JUN-06:02 | 19.37 | 9.22 | 0.874367E+09 | 973.19 | 03-JUN-14:30 | 34.45 | 20.17 |
July | 0.106988E+11 | 20344.20 | 03-JUL-05:01 | 27.62 | 17.60 | 0.868688E+09 | 973.29 | 08-JUL-14:39 | 22.80 | 19.37 |
August | 0.110720E+11 | 23690.23 | 23-AUG-06:02 | 20.28 | 12.06 | 0.905910E+09 | 973.22 | 31-AUG-14:09 | 28.30 | 17.66 |
September | 0.108932E+11 | 25417.64 | 12-SEP-06:02 | 13.63 | 10.11 | 0.856401E+09 | 973.21 | 22-SEP-14:09 | 30.78 | 18.99 |
October | 0.960445E+10 | 24678.03 | 31-OCT-06:02 | 12.85 | 5.96 | 0.867234E+09 | 973.19 | 18-OCT-14:09 | 28.40 | 17.75 |
November | 0.691406E+10 | 24716.02 | 11-NOV-09:02 | 11.65 | 7.10 | 0.827985E+09 | 973.15 | 10-NOV-15:09 | 15.50 | 10.15 |
December | 0.473286E+10 | 7281.91 | 16-DEC-14:10 | 15.00 | 4.27 | 0.845769E+09 | 973.10 | 23-DEC-11:20 | 12.23 | 4.29 |
Annual Sum or Average | 0.936292E+11 | 0.103119E+11 | ||||||||
Minimum of Months | 0.447365E+10 | 7281.91 | 6.47 | 1.45 | 0.779953E+09 | 973.10 | 8.90 | 4.29 | ||
Maximum of Months | 0.110720E+11 | 25417.64 | 27.62 | 17.60 | 0.905910E+09 | 973.29 | 34.45 | 20.17 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.269828E+10 | 5482.93 | 12-JAN-15:10 | 18.90 | 10.02 | 0.813685E+09 | 973.10 | 07-JAN-12:20 | 9.97 | 3.59 |
February | 0.246125E+10 | 5307.97 | 22-FEB-13:30 | 21.15 | 7.67 | 0.755907E+09 | 973.10 | 11-FEB-11:09 | 13.53 | 5.24 |
March | 0.270412E+10 | 5041.04 | 16-MAR-14:10 | 22.80 | 9.21 | 0.873717E+09 | 973.10 | 18-MAR-11:20 | 13.53 | 4.21 |
April | 0.404166E+10 | 19810.61 | 20-APR-06:02 | 20.60 | 8.87 | 0.849607E+09 | 973.14 | 29-APR-12:09 | 27.30 | 15.19 |
May | 0.564517E+10 | 23253.64 | 17-MAY-06:02 | 15.73 | 6.76 | 0.886139E+09 | 973.13 | 27-MAY-12:20 | 30.20 | 16.19 |
June | 0.735195E+10 | 22389.32 | 13-JUN-06:02 | 17.03 | 5.98 | 0.874349E+09 | 973.14 | 20-JUN-14:09 | 33.68 | 18.26 |
July | 0.780951E+10 | 17209.31 | 03-JUL-05:01 | 27.62 | 17.60 | 0.868679E+09 | 973.22 | 08-JUL-14:39 | 22.80 | 19.37 |
August | 0.810110E+10 | 19176.70 | 23-AUG-06:02 | 20.28 | 12.06 | 0.905895E+09 | 973.16 | 05-AUG-14:09 | 32.80 | 19.09 |
September | 0.804537E+10 | 24137.69 | 30-SEP-06:02 | 8.95 | 6.14 | 0.856338E+09 | 973.18 | 23-SEP-15:50 | 20.88 | 18.63 |
October | 0.673186E+10 | 23841.58 | 20-OCT-06:02 | 11.28 | 7.37 | 0.865839E+09 | 973.17 | 03-OCT-14:09 | 32.62 | 19.53 |
November | 0.450814E+10 | 23873.48 | 11-NOV-09:02 | 11.65 | 7.10 | 0.809433E+09 | 973.13 | 10-NOV-15:09 | 15.50 | 10.15 |
December | 0.265024E+10 | 4993.85 | 16-DEC-14:20 | 15.00 | 4.24 | 0.811479E+09 | 973.10 | 23-DEC-11:20 | 12.23 | 4.29 |
Annual Sum or Average | 0.627486E+11 | 0.101711E+11 | ||||||||
Minimum of Months | 0.246125E+10 | 4993.85 | 8.95 | 4.24 | 0.755907E+09 | 973.10 | 9.97 | 3.59 | ||
Maximum of Months | 0.810110E+10 | 24137.69 | 27.62 | 17.60 | 0.905895E+09 | 973.22 | 33.68 | 19.53 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 6.70 | 3.91 | 0.00 | 0.00 | 01-JAN-00:10 | 6.70 | 3.91 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 6.42 | 1.83 | 0.00 | 0.00 | 01-FEB-00:10 | 6.42 | 1.83 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 7.32 | 2.39 | 0.00 | 0.00 | 01-MAR-00:10 | 7.32 | 2.39 |
April | 0.00 | 0.00 | 01-APR-00:10 | 11.18 | 2.38 | 0.00 | 0.00 | 01-APR-00:10 | 11.18 | 2.38 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 20.40 | 8.38 | 0.00 | 0.00 | 01-MAY-00:10 | 20.40 | 8.38 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.03 | 11.53 | 0.00 | 0.00 | 01-JUN-00:10 | 25.03 | 11.53 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.63 | 17.05 | 0.00 | 0.00 | 01-JUL-00:10 | 27.63 | 17.05 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 27.32 | 18.10 | 0.00 | 0.00 | 01-AUG-00:10 | 27.32 | 18.10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 22.63 | 17.17 | 0.00 | 0.00 | 01-SEP-00:10 | 22.63 | 17.17 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.02 | 8.65 | 0.00 | 0.00 | 01-OCT-00:10 | 16.02 | 8.65 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 10.60 | 5.63 | 0.00 | 0.00 | 01-NOV-00:10 | 10.60 | 5.63 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 8.95 | 5.45 | 0.00 | 0.00 | 01-DEC-00:10 | 8.95 | 5.45 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 6.42 | 1.83 | 0.00 | 0.00 | 6.42 | 1.83 | ||
Maximum of Months | 0.00 | 0.00 | 27.63 | 18.10 | 0.00 | 0.00 | 27.63 | 18.10 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.917103E+09 | 51634.89 | 28-JAN-06:01 | -3.3 |
February | 0.708196E+09 | 50891.27 | 02-FEB-06:02 | -3.5 |
March | 0.419505E+09 | 43695.25 | 02-MAR-06:03 | -3.5 |
April | 0.253070E+09 | 2682.55 | 20-APR-06:04 | 20.60 |
May | 0.209635E+09 | 3157.40 | 30-MAY-06:06 | 25.10 |
June | 64729734.76 | 3501.53 | 18-JUN-08:06 | 26.47 |
July | 53924724.71 | 3704.39 | 16-JUL-08:06 | 27.30 |
August | 67905448.44 | 3671.85 | 27-AUG-08:06 | 27.15 |
September | 0.105622E+09 | 3126.86 | 10-SEP-08:06 | 23.58 |
October | 0.224509E+09 | 2589.58 | 02-OCT-06:06 | 22.70 |
November | 0.311058E+09 | 51326.40 | 28-NOV-06:02 | 1.02 |
December | 0.109118E+10 | 51697.69 | 27-DEC-06:01 | -3.5 |
Annual Sum or Average | 0.442644E+10 | |||
Minimum of Months | 53924724.71 | 2589.58 | -3.5 | |
Maximum of Months | 0.109118E+10 | 51697.69 | 27.30 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.164523E+10 | 23354.33 | 27-JAN-07:10 | -4.3 |
February | 0.148670E+10 | 16146.53 | 02-FEB-06:25 | -3.9 |
March | 0.163418E+10 | 16058.39 | 02-MAR-06:33 | -2.4 |
April | 0.127419E+10 | 15946.10 | 11-APR-05:55 | 4.40 |
May | 0.612572E+09 | 19681.67 | 30-MAY-06:06 | 25.10 |
June | 0.253246E+09 | 22445.81 | 18-JUN-08:06 | 26.47 |
July | 0.291205E+09 | 24835.30 | 02-JUL-08:06 | 27.48 |
August | 0.297140E+09 | 23589.99 | 06-AUG-08:06 | 26.97 |
September | 0.351084E+09 | 18024.45 | 10-SEP-08:06 | 23.58 |
October | 0.113837E+10 | 17059.68 | 02-OCT-05:04 | 23.72 |
November | 0.154633E+10 | 15971.67 | 28-NOV-06:45 | 0.68 |
December | 0.178657E+10 | 50145.96 | 27-DEC-06:01 | -3.5 |
Annual Sum or Average | 0.123168E+11 | |||
Minimum of Months | 0.253246E+09 | 15946.10 | -4.3 | |
Maximum of Months | 0.178657E+10 | 50145.96 | 27.48 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.149330E+09 | 6830.18 | 26-JAN-06:02 | 1.52 |
February | 0.132356E+09 | 2413.62 | 02-FEB-06:02 | -3.5 |
March | 0.144750E+09 | 2543.92 | 01-MAR-06:03 | 1.60 |
April | 0.130670E+09 | 1798.84 | 20-APR-06:04 | 20.60 |
May | 76081653.47 | 2294.31 | 30-MAY-06:04 | 25.10 |
June | 23999066.17 | 2233.77 | 15-JUN-05:04 | 27.02 |
July | 25081023.53 | 2190.41 | 07-JUL-05:05 | 24.03 |
August | 23664426.88 | 2300.99 | 24-AUG-05:04 | 25.00 |
September | 29897939.57 | 2227.54 | 13-SEP-05:05 | 23.12 |
October | 87480675.56 | 2355.53 | 02-OCT-05:04 | 23.72 |
November | 0.131273E+09 | 12614.32 | 28-NOV-06:02 | 1.02 |
December | 0.175704E+09 | 30736.99 | 27-DEC-06:01 | -3.5 |
Annual Sum or Average | 0.113029E+10 | |||
Minimum of Months | 23664426.88 | 1798.84 | -3.5 | |
Maximum of Months | 0.175704E+09 | 30736.99 | 27.02 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.216152E+09 | 24728.81 | 28-JAN-06:01 | -3.3 |
February | 0.163065E+09 | 17006.57 | 02-FEB-06:02 | -3.5 |
March | 0.146683E+09 | 14960.71 | 02-MAR-06:03 | -3.5 |
April | 0.113041E+09 | 1163.06 | 20-APR-06:04 | 20.60 |
May | 0.105046E+09 | 1580.82 | 14-MAY-08:04 | 23.58 |
June | 40112143.49 | 1619.62 | 15-JUN-05:04 | 27.02 |
July | 23956343.55 | 1919.26 | 02-JUL-08:06 | 27.48 |
August | 29942296.51 | 1618.19 | 06-AUG-07:04 | 25.28 |
September | 36493313.84 | 1414.20 | 13-SEP-05:05 | 23.12 |
October | 96675059.47 | 1720.45 | 02-OCT-05:04 | 23.72 |
November | 0.139511E+09 | 25185.36 | 28-NOV-06:02 | 1.02 |
December | 0.258615E+09 | 25392.10 | 27-DEC-06:01 | -3.5 |
Annual Sum or Average | 0.136929E+10 | |||
Minimum of Months | 23956343.55 | 1163.06 | -3.5 | |
Maximum of Months | 0.258615E+09 | 25392.10 | 27.48 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.623462E+10 | 17334.04 | 26-JAN-12:10 | 3.98 |
February | 0.377839E+10 | 14656.78 | 02-FEB-12:10 | 6.88 |
March | 0.265707E+10 | 15386.73 | 01-MAR-18:00 | 6.10 |
April | 0.648584E+09 | 9507.92 | 11-APR-11:07 | 12.07 |
May | 26388096.83 | 2376.18 | 01-MAY-11:10 | 19.40 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 25.03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 27.63 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 27.32 |
September | 9971832.12 | 2275.57 | 23-SEP-17:00 | 17.80 |
October | 0.581850E+09 | 7893.80 | 24-OCT-11:10 | 13.07 |
November | 0.344425E+10 | 15629.85 | 26-NOV-18:00 | 6.10 |
December | 0.698138E+10 | 21130.44 | 26-DEC-12:10 | 1.20 |
Annual Sum or Average | 0.243625E+11 | |||
Minimum of Months | 0.00 | 0.00 | 1.20 | |
Maximum of Months | 0.698138E+10 | 21130.44 | 27.63 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.290080E+10 | 2413.46 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.263912E+10 | 2413.46 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.300979E+10 | 2413.46 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.284005E+10 | 2413.46 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.295530E+10 | 2413.46 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.290440E+10 | 2413.46 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.289095E+10 | 2413.46 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.300979E+10 | 2413.46 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.284005E+10 | 2413.46 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.290080E+10 | 2413.46 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.280526E+10 | 2413.46 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.289095E+10 | 2413.46 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.345872E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.263912E+10 | 2413.46 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.300979E+10 | 2413.46 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.254111E+11 | 23840.77 | 02-JAN-09:09 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.221098E+11 | 23840.77 | 01-FEB-15:39 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.231685E+11 | 23840.77 | 01-MAR-16:19 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.209167E+11 | 23840.77 | 03-APR-16:49 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.216438E+11 | 23840.77 | 02-MAY-16:30 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.216514E+11 | 23840.77 | 03-JUN-16:30 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.212630E+11 | 23840.77 | 03-JUL-16:19 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.221297E+11 | 23840.77 | 02-AUG-16:30 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.209239E+11 | 23840.77 | 01-SEP-16:30 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.235904E+11 | 23840.77 | 02-OCT-16:19 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.246794E+11 | 23840.77 | 01-NOV-16:10 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.252526E+11 | 23840.77 | 01-DEC-15:50 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.272740E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.209167E+11 | 23840.77 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.254111E+11 | 23840.77 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.268183E+10 | 2246.46 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.244011E+10 | 2246.46 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.278337E+10 | 2246.46 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.262612E+10 | 2246.46 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.273260E+10 | 2246.46 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.268587E+10 | 2246.46 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.267284E+10 | 2246.46 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.278337E+10 | 2246.46 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.262612E+10 | 2246.46 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.268183E+10 | 2246.46 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.259332E+10 | 2246.46 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.267284E+10 | 2246.46 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.319802E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.244011E+10 | 2246.46 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.278337E+10 | 2246.46 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.268183E+10 | 2246.46 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.244011E+10 | 2246.46 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.278337E+10 | 2246.46 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.262612E+10 | 2246.46 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.273260E+10 | 2246.46 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.268587E+10 | 2246.46 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.267284E+10 | 2246.46 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.278337E+10 | 2246.46 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.262612E+10 | 2246.46 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.268183E+10 | 2246.46 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.259332E+10 | 2246.46 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.267284E+10 | 2246.46 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.319802E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.244011E+10 | 2246.46 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.278337E+10 | 2246.46 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.163184E+09 | 136.69 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.148475E+09 | 136.69 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.169362E+09 | 136.69 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.159794E+09 | 136.69 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.166273E+09 | 136.69 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.163430E+09 | 136.69 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.162637E+09 | 136.69 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.169362E+09 | 136.69 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.159794E+09 | 136.69 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.163184E+09 | 136.69 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.157798E+09 | 136.69 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.162637E+09 | 136.69 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.194593E+10 | ||||
Minimum of Months | 0.148475E+09 | 136.69 | 0.00 | 0.00 | |
Maximum of Months | 0.169362E+09 | 136.69 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.290080E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215072E+10 |
February | 0.479114E+10 | 0.263912E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195698E+10 |
March | 0.548013E+10 | 0.300979E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 869859.96 | 0.197171E+10 |
April | 0.518069E+10 | 0.284005E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.107683E+09 | 0.110279E+10 |
May | 0.536353E+10 | 0.295530E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.290185E+09 | 0.618559E+09 |
June | 0.528933E+10 | 0.290440E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.490166E+09 | 0.249414E+09 |
July | 0.525489E+10 | 0.289095E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379657E+09 | 0.201077E+09 |
August | 0.548013E+10 | 0.300979E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.288264E+09 | 0.270288E+09 |
September | 0.518069E+10 | 0.284005E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 95821938.64 | 0.317841E+09 |
October | 0.524694E+10 | 0.290080E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 33859046.16 | 0.101499E+10 |
November | 0.504819E+10 | 0.280526E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6.44 | 0.180239E+10 |
December | 0.525489E+10 | 0.289095E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.191643E+10 |
Annual Sum or Average | 0.628175E+11 | 0.345872E+11 | 0.499918E+11 | 0.168650E+10 | 0.135732E+11 | ||||
Minimum of Months | 0.479114E+10 | 0.263912E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.201077E+09 |
Maximum of Months | 0.548013E+10 | 0.300979E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.490166E+09 | 0.215072E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.254111E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198331E+10 |
February | 0.201852E+11 | 0.221098E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182282E+10 |
March | 0.230879E+11 | 0.231685E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 712525.45 | 0.184496E+10 |
April | 0.218263E+11 | 0.209167E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 86533646.93 | 0.103159E+10 |
May | 0.225967E+11 | 0.216438E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235881E+09 | 0.579084E+09 |
June | 0.222841E+11 | 0.216514E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404370E+09 | 0.220778E+09 |
July | 0.221389E+11 | 0.212630E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.317281E+09 | 0.171297E+09 |
August | 0.230879E+11 | 0.221297E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.238364E+09 | 0.232905E+09 |
September | 0.218263E+11 | 0.209239E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 78483254.27 | 0.271864E+09 |
October | 0.221054E+11 | 0.235904E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 27151014.24 | 0.894764E+09 |
November | 0.212681E+11 | 0.246794E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4.27 | 0.162559E+10 |
December | 0.221389E+11 | 0.252526E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.173834E+10 |
Annual Sum or Average | 0.264651E+12 | 0.272740E+12 | 0.842987E+11 | 0.138878E+10 | 0.124173E+11 | ||||
Minimum of Months | 0.201852E+11 | 0.209167E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171297E+09 |
Maximum of Months | 0.230879E+11 | 0.254111E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404370E+09 | 0.198331E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.268183E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104251E+10 |
February | 0.190200E+10 | 0.244011E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.937741E+09 |
March | 0.217552E+10 | 0.278337E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 377128.18 | 0.931833E+09 |
April | 0.205665E+10 | 0.262612E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44732857.21 | 0.523908E+09 |
May | 0.212923E+10 | 0.273260E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118362E+09 | 0.300987E+09 |
June | 0.209978E+10 | 0.268587E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199061E+09 | 0.127658E+09 |
July | 0.208610E+10 | 0.267284E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151791E+09 | 0.108363E+09 |
August | 0.217552E+10 | 0.278337E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.114624E+09 | 0.145253E+09 |
September | 0.205665E+10 | 0.262612E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 40283750.57 | 0.165249E+09 |
October | 0.208295E+10 | 0.268183E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11821188.46 | 0.495152E+09 |
November | 0.200405E+10 | 0.259332E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.64 | 0.865200E+09 |
December | 0.208610E+10 | 0.267284E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.920485E+09 |
Annual Sum or Average | 0.249375E+11 | 0.319802E+11 | 0.529224E+11 | 0.681052E+09 | 0.656434E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.244011E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108363E+09 |
Maximum of Months | 0.217552E+10 | 0.278337E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199061E+09 | 0.104251E+10 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.268183E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.985921E+09 |
February | 0.190200E+10 | 0.244011E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.889824E+09 |
March | 0.217552E+10 | 0.278337E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 377113.68 | 0.881352E+09 |
April | 0.205665E+10 | 0.262612E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 45541829.61 | 0.485316E+09 |
May | 0.212923E+10 | 0.273260E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123744E+09 | 0.262931E+09 |
June | 0.209978E+10 | 0.268587E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209521E+09 | 0.103189E+09 |
July | 0.208610E+10 | 0.267284E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160930E+09 | 84959299.09 |
August | 0.217552E+10 | 0.278337E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120332E+09 | 0.121517E+09 |
September | 0.205665E+10 | 0.262612E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 40679349.72 | 0.148437E+09 |
October | 0.208295E+10 | 0.268183E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 12451623.82 | 0.466800E+09 |
November | 0.200405E+10 | 0.259332E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2.23 | 0.826292E+09 |
December | 0.208610E+10 | 0.267284E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.876031E+09 |
Annual Sum or Average | 0.249375E+11 | 0.319802E+11 | 0.794328E+10 | 0.713577E+09 | 0.613257E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.244011E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84959299.09 |
Maximum of Months | 0.217552E+10 | 0.278337E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209521E+09 | 0.985921E+09 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.163184E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.694470E+10 |
February | 0.00 | 0.148475E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.438986E+10 |
March | 0.00 | 0.169362E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.323638E+10 |
April | 0.00 | 0.159794E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54046170.00 | 0.963055E+09 |
May | 0.00 | 0.166273E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228255E+09 | 0.177095E+09 |
June | 0.00 | 0.163430E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528944E+09 | 64597823.23 |
July | 0.00 | 0.162637E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.400415E+09 | 65877312.88 |
August | 0.00 | 0.169362E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265433E+09 | 0.136787E+09 |
September | 0.00 | 0.159794E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75080034.31 | 0.236082E+09 |
October | 0.00 | 0.163184E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5607701.88 | 0.136082E+10 |
November | 0.00 | 0.157798E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.441265E+10 |
December | 0.00 | 0.162637E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.766543E+10 |
Annual Sum or Average | 0.00 | 0.194593E+10 | 0.155778E+10 | 0.296533E+11 | |||||
Minimum of Months | 0.00 | 0.148475E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64597823.23 |
Maximum of Months | 0.00 | 0.169362E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528944E+09 | 0.766543E+10 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 2413.46 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 5834.95 | 25-JAN-23:00 |
February | 5888.82 | 01-FEB-15:09 | 2413.46 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 8398.69 | 08-FEB-21:03 |
March | 5888.82 | 01-MAR-15:09 | 2413.46 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 70.23 | 22-MAR-13:00 | 5249.81 | 19-MAR-24:00 |
April | 5888.82 | 01-APR-10:09 | 2413.46 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 946.37 | 21-APR-15:00 | 6118.23 | 10-APR-24:00 |
May | 5888.82 | 01-MAY-14:09 | 2413.46 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2094.91 | 14-MAY-18:03 | 2578.92 | 04-MAY-02:00 |
June | 5888.82 | 01-JUN-14:09 | 2413.46 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3037.78 | 21-JUN-20:02 | 2397.31 | 28-JUN-02:00 |
July | 5888.82 | 01-JUL-10:09 | 2413.46 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2237.74 | 02-JUL-18:02 | 1382.20 | 18-JUL-21:00 |
August | 5888.82 | 01-AUG-14:09 | 2413.46 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1338.18 | 06-AUG-18:02 | 1915.57 | 14-AUG-01:00 |
September | 5888.82 | 01-SEP-14:09 | 2413.46 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 746.74 | 10-SEP-18:03 | 1177.30 | 24-SEP-07:00 |
October | 5888.82 | 02-OCT-14:09 | 2413.46 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 602.61 | 01-OCT-18:03 | 3155.38 | 23-OCT-21:00 |
November | 5888.82 | 01-NOV-14:09 | 2413.46 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 | 03-NOV-16:00 | 3459.01 | 04-NOV-04:00 |
December | 5888.82 | 01-DEC-15:09 | 2413.46 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 4794.99 | 18-DEC-06:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 2413.46 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1177.30 | |||||
Maximum of Months | 5888.82 | 2413.46 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 3037.78 | 8398.69 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 23840.77 | 02-JAN-09:09 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 5830.44 | 25-JAN-23:00 |
February | 24809.68 | 01-FEB-15:09 | 23840.77 | 01-FEB-15:39 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 7400.55 | 09-FEB-01:00 |
March | 24809.68 | 01-MAR-15:09 | 23840.77 | 01-MAR-16:19 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 57.51 | 22-MAR-13:00 | 5551.82 | 19-MAR-24:00 |
April | 24809.68 | 01-APR-10:09 | 23840.77 | 03-APR-16:49 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 774.66 | 21-APR-15:00 | 5910.70 | 10-APR-24:00 |
May | 24809.68 | 01-MAY-14:09 | 23840.77 | 02-MAY-16:30 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1725.84 | 14-MAY-18:03 | 2731.09 | 04-MAY-02:00 |
June | 24809.68 | 01-JUN-14:09 | 23840.77 | 03-JUN-16:30 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2509.55 | 21-JUN-20:02 | 2178.24 | 28-JUN-02:00 |
July | 24809.68 | 01-JUL-10:09 | 23840.77 | 03-JUL-16:19 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1841.74 | 02-JUL-18:02 | 1232.69 | 18-JUL-21:00 |
August | 24809.68 | 01-AUG-14:09 | 23840.77 | 02-AUG-16:30 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1100.22 | 06-AUG-18:02 | 1697.82 | 14-AUG-01:00 |
September | 24809.68 | 01-SEP-14:09 | 23840.77 | 01-SEP-16:30 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 615.27 | 10-SEP-18:03 | 1025.61 | 24-SEP-07:00 |
October | 24809.68 | 02-OCT-14:09 | 23840.77 | 02-OCT-16:19 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 493.08 | 01-OCT-18:03 | 2879.09 | 23-OCT-21:00 |
November | 24809.68 | 01-NOV-14:09 | 23840.77 | 01-NOV-16:10 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 | 08-NOV-15:00 | 3246.21 | 04-NOV-04:00 |
December | 24809.68 | 01-DEC-15:09 | 23840.77 | 01-DEC-15:50 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 4686.65 | 18-DEC-06:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 23840.77 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1025.61 | |||||
Maximum of Months | 24809.68 | 23840.77 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 2509.55 | 7400.55 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2246.46 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2770.97 | 25-JAN-23:00 |
February | 2337.76 | 01-FEB-15:09 | 2246.46 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3894.93 | 08-FEB-21:03 |
March | 2337.76 | 01-MAR-15:09 | 2246.46 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 30.44 | 22-MAR-13:00 | 2537.46 | 19-MAR-24:00 |
April | 2337.76 | 01-APR-10:09 | 2246.46 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 410.09 | 21-APR-15:00 | 2743.94 | 10-APR-24:00 |
May | 2337.76 | 01-MAY-14:09 | 2246.46 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 892.57 | 14-MAY-18:03 | 1237.00 | 04-MAY-02:00 |
June | 2337.76 | 01-JUN-14:09 | 2246.46 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1295.61 | 21-JUN-20:02 | 1081.04 | 28-JUN-02:00 |
July | 2337.76 | 01-JUL-10:09 | 2246.46 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 960.29 | 02-JUL-18:02 | 670.78 | 18-JUL-21:00 |
August | 2337.76 | 01-AUG-14:09 | 2246.46 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 573.38 | 06-AUG-18:02 | 900.96 | 14-AUG-01:00 |
September | 2337.76 | 01-SEP-14:09 | 2246.46 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 312.85 | 10-SEP-18:03 | 536.33 | 24-SEP-07:00 |
October | 2337.76 | 02-OCT-14:09 | 2246.46 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 250.57 | 01-OCT-18:03 | 1517.47 | 23-OCT-21:00 |
November | 2337.76 | 01-NOV-14:09 | 2246.46 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 08-NOV-15:00 | 1654.97 | 04-NOV-04:00 |
December | 2337.76 | 01-DEC-15:09 | 2246.46 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2343.78 | 18-DEC-05:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2246.46 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 536.33 | |||||
Maximum of Months | 2337.76 | 2246.46 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 1295.61 | 3894.93 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2246.46 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 2560.24 | 25-JAN-23:00 |
February | 2337.76 | 01-FEB-15:09 | 2246.46 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3628.71 | 08-FEB-21:03 |
March | 2337.76 | 01-MAR-15:09 | 2246.46 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 30.44 | 22-MAR-13:00 | 2418.57 | 19-MAR-24:00 |
April | 2337.76 | 01-APR-10:09 | 2246.46 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 410.10 | 21-APR-15:00 | 2634.24 | 10-APR-24:00 |
May | 2337.76 | 01-MAY-14:09 | 2246.46 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 900.06 | 14-MAY-18:03 | 1098.14 | 04-MAY-02:00 |
June | 2337.76 | 01-JUN-14:09 | 2246.46 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1306.27 | 21-JUN-20:02 | 994.01 | 28-JUN-02:00 |
July | 2337.76 | 01-JUL-10:09 | 2246.46 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 963.84 | 02-JUL-18:02 | 608.29 | 18-JUL-21:00 |
August | 2337.76 | 01-AUG-14:09 | 2246.46 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 575.67 | 06-AUG-18:02 | 837.37 | 14-AUG-01:00 |
September | 2337.76 | 01-SEP-14:09 | 2246.46 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 316.56 | 10-SEP-18:03 | 506.17 | 24-SEP-07:00 |
October | 2337.76 | 02-OCT-14:09 | 2246.46 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 253.00 | 01-OCT-18:03 | 1456.99 | 23-OCT-21:00 |
November | 2337.76 | 01-NOV-14:09 | 2246.46 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 08-NOV-15:00 | 1585.41 | 04-NOV-04:00 |
December | 2337.76 | 01-DEC-15:09 | 2246.46 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2242.36 | 18-DEC-05:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2246.46 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 506.17 | |||||
Maximum of Months | 2337.76 | 2246.46 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 1306.27 | 3628.71 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 136.69 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 17988.20 | 26-JAN-12:10 |
February | 0.00 | 01-FEB-00:10 | 136.69 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 15240.66 | 02-FEB-12:10 |
March | 0.00 | 01-MAR-00:10 | 136.69 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 15760.64 | 01-MAR-18:00 |
April | 0.00 | 01-APR-00:10 | 136.69 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 748.53 | 19-APR-11:02 | 10205.68 | 11-APR-11:03 |
May | 0.00 | 01-MAY-00:10 | 136.69 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1878.72 | 19-MAY-11:01 | 2975.44 | 01-MAY-11:10 |
June | 0.00 | 01-JUN-00:10 | 136.69 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2588.91 | 15-JUN-11:01 | 1031.64 | 29-JUN-11:02 |
July | 0.00 | 01-JUL-00:10 | 136.69 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2197.52 | 03-JUL-11:01 | 1033.10 | 08-JUL-14:55 |
August | 0.00 | 01-AUG-00:10 | 136.69 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1520.02 | 06-AUG-11:02 | 1949.37 | 14-AUG-11:02 |
September | 0.00 | 01-SEP-00:10 | 136.69 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 777.18 | 17-SEP-11:02 | 3508.09 | 23-SEP-17:00 |
October | 0.00 | 01-OCT-00:10 | 136.69 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 301.44 | 03-OCT-14:00 | 8766.81 | 24-OCT-11:10 |
November | 0.00 | 01-NOV-00:10 | 136.69 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 15716.60 | 26-NOV-18:00 |
December | 0.00 | 01-DEC-00:10 | 136.69 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 21128.12 | 26-DEC-12:10 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 136.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1031.64 | ||||
Maximum of Months | 0.00 | 136.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2588.91 | 21128.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4202.47 | 27-JAN-07:07 | 2208.31 | 1608.97 | 3678.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 803.51 |
February | 4620.35 | 03-FEB-07:05 | 2944.41 | 2145.30 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 289.74 |
March | 5634.65 | 16-MAR-15:00 | 5888.82 | 2413.46 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.56 |
April | 38705.22 | 29-APR-06:02 | 3680.51 | 1340.81 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 124.05 |
May | 50009.01 | 12-MAY-06:02 | 3680.51 | 2681.62 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 186.24 |
June | 44363.20 | 13-JUN-06:02 | 3680.51 | 2681.62 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.15 |
July | 32825.59 | 03-JUL-05:01 | 0.00 | 1035.60 | 4292.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 | 0.00 |
August | 39392.55 | 23-AUG-06:02 | 3680.51 | 2681.62 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.55 |
September | 48492.56 | 30-SEP-06:02 | 3680.51 | 1340.81 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 156.32 |
October | 41958.03 | 20-OCT-06:02 | 3680.51 | 2681.62 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 209.38 |
November | 9246.25 | 10-NOV-07:02 | 3680.51 | 2681.62 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 932.28 |
December | 4324.64 | 27-DEC-07:05 | 2944.41 | 2145.30 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 490.33 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4202.47 | 0.00 | 1035.60 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 50009.01 | 5888.82 | 2681.62 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 | 932.28 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 34777.67 | 14-JAN-07:03 | 9303.63 | 7946.92 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 355.99 |
February | 125104.98 | 08-FEB-07:03 | 12404.84 | 21191.80 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 253.17 |
March | 227833.86 | 10-MAR-07:02 | 15506.05 | 26489.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.28 |
April | 247052.04 | 15-APR-06:02 | 15506.05 | 13244.87 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 320.77 |
May | 234082.56 | 06-MAY-06:02 | 15506.05 | 13244.87 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 160.71 |
June | 194935.07 | 13-JUN-06:02 | 15506.05 | 26489.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.87 |
July | 148387.46 | 03-JUL-05:01 | 0.00 | 9271.41 | 7237.38 | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 0.00 |
August | 165929.67 | 23-AUG-06:02 | 15506.05 | 26489.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.29 |
September | 215572.49 | 30-SEP-06:02 | 15506.05 | 13244.87 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 130.29 |
October | 220550.44 | 24-OCT-06:02 | 15506.05 | 26489.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 222.13 |
November | 215935.07 | 04-NOV-06:02 | 15506.05 | 13244.87 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 433.09 |
December | 31851.28 | 22-DEC-07:03 | 12404.84 | 21191.80 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 433.53 |
Annual Sum or Average | |||||||||||
Minimum of Months | 31851.28 | 0.00 | 7946.92 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 247052.04 | 15506.05 | 26489.75 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 433.53 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 7809.11 | 12-JAN-15:10 | 2337.76 | 2246.46 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.54 |
February | 7577.29 | 22-FEB-13:30 | 2045.54 | 2246.46 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.13 |
March | 11004.19 | 16-MAR-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 163.77 |
April | 24258.69 | 28-APR-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 128.27 |
May | 24429.70 | 11-MAY-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.88 |
June | 25091.73 | 01-JUN-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28.35 |
July | 20344.20 | 03-JUL-05:01 | 0.00 | 873.62 | 4543.60 | 0.00 | 0.00 | 0.00 | 0.00 | 2.89 | 0.00 |
August | 23690.23 | 23-AUG-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.16 |
September | 25417.64 | 12-SEP-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.27 |
October | 24678.03 | 31-OCT-06:02 | 1461.10 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 154.56 |
November | 24716.02 | 11-NOV-09:02 | 1461.10 | 1248.04 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.86 |
December | 7281.91 | 16-DEC-14:10 | 2337.76 | 2246.46 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.84 |
Annual Sum or Average | |||||||||||
Minimum of Months | 7281.91 | 0.00 | 873.62 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 25417.64 | 2337.76 | 2496.07 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 2.89 | 163.77 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5482.93 | 12-JAN-15:10 | 2337.76 | 2246.46 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.54 |
February | 5307.97 | 22-FEB-13:30 | 2045.54 | 2246.46 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.13 |
March | 5041.04 | 16-MAR-14:10 | 2337.76 | 2246.46 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.55 |
April | 19810.61 | 20-APR-06:02 | 1461.10 | 2496.07 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 69.08 |
May | 23253.64 | 17-MAY-06:02 | 1461.10 | 2496.07 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.49 |
June | 22389.32 | 13-JUN-06:02 | 1461.10 | 2496.07 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.87 |
July | 17209.31 | 03-JUL-05:01 | 0.00 | 873.62 | 681.96 | 0.00 | 0.00 | 0.00 | 0.00 | 6.61 | 0.00 |
August | 19176.70 | 23-AUG-06:02 | 1461.10 | 2496.07 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.49 |
September | 24137.69 | 30-SEP-06:02 | 1461.10 | 1248.04 | 730.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.88 |
October | 23841.58 | 20-OCT-06:02 | 1461.10 | 2496.07 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.07 |
November | 23873.48 | 11-NOV-09:02 | 1461.10 | 1248.04 | 730.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96.59 |
December | 4993.85 | 16-DEC-14:20 | 2337.76 | 2246.46 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.56 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4993.85 | 0.00 | 873.62 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 24137.69 | 2337.76 | 2496.07 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 6.61 | 103.56 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 72.34 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 180.27 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 98.63 |
April | 0.00 | 01-APR-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.55 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.30 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.46 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.45 | 0.00 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.87 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.30 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.07 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76.43 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.36 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 7.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.45 | 180.27 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.937861E+11 | 71812.31 | 03-JAN-17:30 | 0.165624E+11 | 70350.25 | 27-JAN-07:30 |
February | 0.847679E+11 | 76407.67 | 21-FEB-16:30 | 0.119037E+11 | 67582.00 | 03-FEB-07:30 |
March | 0.953142E+11 | 83290.92 | 21-MAR-15:00 | 0.103098E+11 | 53394.80 | 02-MAR-07:30 |
April | 0.104207E+12 | 93375.29 | 19-APR-16:30 | 0.780838E+10 | 12920.70 | 11-APR-11:09 |
May | 0.123412E+12 | 102843.78 | 19-MAY-16:19 | 0.757697E+10 | 4916.16 | 01-MAY-11:09 |
June | 0.136360E+12 | 112787.11 | 15-JUN-15:30 | 0.718901E+10 | 4866.90 | 01-JUN-11:20 |
July | 0.143229E+12 | 112999.56 | 03-JUL-16:19 | 0.727471E+10 | 4831.99 | 03-JUL-11:30 |
August | 0.138761E+12 | 110709.96 | 04-AUG-16:10 | 0.733714E+10 | 4833.68 | 31-AUG-11:09 |
September | 0.126116E+12 | 105993.39 | 01-SEP-15:30 | 0.716681E+10 | 4866.42 | 29-SEP-11:09 |
October | 0.109351E+12 | 102702.09 | 04-OCT-16:19 | 0.779902E+10 | 11491.78 | 24-OCT-11:09 |
November | 0.926758E+11 | 85951.05 | 03-NOV-15:00 | 0.103960E+11 | 52267.99 | 28-NOV-07:19 |
December | 0.936604E+11 | 69328.10 | 01-DEC-17:00 | 0.199428E+11 | 106585.66 | 27-DEC-07:10 |
Annual Sum or Average | 0.134164E+13 | 0.121267E+12 | ||||
Minimum of Months | 0.847679E+11 | 69328.10 | 0.716681E+10 | 4831.99 | ||
Maximum of Months | 0.143229E+12 | 112999.56 | 0.199428E+11 | 106585.66 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.338387E+11 | 0.717275E+10 | 0.164409E+11 | 0.00 | 0.361961E+11 | 0.00 | 0.00 | 0.137687E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.297776E+11 | 0.613613E+10 | 0.149157E+11 | 0.00 | 0.324249E+11 | 0.00 | 0.00 | 0.151357E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.319144E+11 | 0.630611E+10 | 0.168545E+11 | 0.00 | 0.359796E+11 | 0.00 | 0.00 | 0.425962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.291688E+11 | 0.561224E+10 | 0.160165E+11 | 0.00 | 0.335170E+11 | 0.00 | 0.00 | 0.198929E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.302305E+11 | 0.537817E+10 | 0.166477E+11 | 0.00 | 0.341090E+11 | 0.00 | 0.00 | 0.370469E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.300910E+11 | 0.499361E+10 | 0.162772E+11 | 0.00 | 0.332370E+11 | 0.00 | 0.00 | 0.517616E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.296623E+11 | 0.525277E+10 | 0.163871E+11 | 0.00 | 0.338441E+11 | 0.00 | 0.00 | 0.580830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.308756E+11 | 0.561224E+10 | 0.168545E+11 | 0.00 | 0.343753E+11 | 0.00 | 0.00 | 0.510435E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.291760E+11 | 0.588533E+10 | 0.160165E+11 | 0.00 | 0.330219E+11 | 0.00 | 0.00 | 0.420157E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.320180E+11 | 0.659313E+10 | 0.164409E+11 | 0.00 | 0.342187E+11 | 0.00 | 0.00 | 0.200800E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.328291E+11 | 0.680770E+10 | 0.159174E+11 | 0.00 | 0.342249E+11 | 0.00 | 0.00 | 0.289665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.336519E+11 | 0.727864E+10 | 0.163871E+11 | 0.00 | 0.363303E+11 | 0.00 | 0.00 | 12487782.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.373234E+12 | 0.730288E+11 | 0.195156E+12 | 0.411479E+12 | 0.00 | 0.288744E+12 | |||||||
Minimum of Months | 0.291688E+11 | 0.499361E+10 | 0.149157E+11 | 0.00 | 0.324249E+11 | 0.00 | 0.00 | 12487782.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.338387E+11 | 0.727864E+10 | 0.168545E+11 | 0.00 | 0.363303E+11 | 0.00 | 0.00 | 0.580830E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.853941E+10 | 0.00 | 0.802298E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.464529E+10 | 0.00 | 0.725844E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.231441E+10 | 0.00 | 0.799534E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.287937E+09 | 0.00 | 0.752045E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.757697E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.718901E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.727471E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.733714E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 78153.85 | 0.00 | 0.716673E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.251462E+09 | 0.00 | 0.754756E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.290244E+10 | 0.00 | 0.749353E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.120087E+11 | 0.00 | 0.793406E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.309498E+11 | 0.903169E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.716673E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.120087E+11 | 0.00 | 0.802298E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 30883.85 | 02-JAN-09:09 | 4644.36 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 22940.89 | 05-JAN-12:09 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 30883.85 | 01-FEB-15:39 | 4644.36 | 01-FEB-00:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 22940.89 | 05-FEB-08:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 30883.85 | 01-MAR-16:19 | 4644.36 | 01-MAR-00:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 22940.89 | 12-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 30883.85 | 03-APR-16:49 | 4644.36 | 01-APR-00:10 | 10771.04 | 01-APR-09:09 | 0.00 | 22940.89 | 07-APR-10:09 | 0.00 | 0.00 | 01-APR-00:10 |
May | 30883.85 | 02-MAY-16:30 | 4644.36 | 01-MAY-00:10 | 10771.04 | 01-MAY-08:09 | 0.00 | 22940.89 | 01-MAY-11:20 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 30883.85 | 03-JUN-16:30 | 4644.36 | 01-JUN-00:10 | 10771.04 | 01-JUN-08:09 | 0.00 | 21078.79 | 01-JUN-05:30 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 30883.85 | 03-JUL-16:19 | 4644.36 | 01-JUL-00:10 | 10771.04 | 01-JUL-09:09 | 0.00 | 21078.79 | 01-JUL-05:10 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 30883.85 | 02-AUG-16:30 | 4644.36 | 01-AUG-00:10 | 10771.04 | 01-AUG-08:09 | 0.00 | 21078.79 | 19-AUG-06:49 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 30883.85 | 01-SEP-16:30 | 4644.36 | 01-SEP-00:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 22940.89 | 23-SEP-16:10 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 30883.85 | 02-OCT-16:19 | 4644.36 | 01-OCT-00:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 22940.89 | 13-OCT-15:50 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 30883.85 | 01-NOV-16:10 | 4644.36 | 01-NOV-00:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 22940.89 | 04-NOV-11:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 30883.85 | 01-DEC-15:50 | 4644.36 | 01-DEC-00:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 22940.89 | 03-DEC-09:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 30883.85 | 4644.36 | 10771.04 | 0.00 | 21078.79 | 0.00 | 0.00 | |||||
Maximum of Months | 30883.85 | 4644.36 | 10771.04 | 0.00 | 22940.89 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 6519.46 | 03-JAN-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 14994.30 | 21-FEB-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 21088.17 | 22-MAR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 37347.33 | 21-APR-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 45058.74 | 19-MAY-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 55188.85 | 15-JUN-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 55731.65 | 26-JUL-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 51777.95 | 04-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 46428.24 | 01-SEP-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 44913.72 | 03-OCT-14:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 23217.37 | 03-NOV-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 780.59 | 23-DEC-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 780.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 55731.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 71812.31 | 03-JAN-17:30 | 30883.85 | 10771.04 | 4644.36 | 0.00 | 22940.89 | 0.00 | 0.00 | 2572.18 | 0.00 |
February | 76407.67 | 21-FEB-16:30 | 30883.85 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 13673.99 | 0.00 |
March | 83290.92 | 21-MAR-15:00 | 30883.85 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 20557.24 | 0.00 |
April | 93375.29 | 19-APR-16:30 | 28897.12 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 32628.34 | 0.00 |
May | 102843.78 | 19-MAY-16:19 | 28897.12 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 42096.83 | 0.00 |
June | 112787.11 | 15-JUN-15:30 | 26910.39 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 54026.89 | 0.00 |
July | 112999.56 | 03-JUL-16:19 | 30883.85 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 50265.88 | 0.00 |
August | 110709.96 | 04-AUG-16:10 | 28897.12 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 49963.01 | 0.00 |
September | 105993.39 | 01-SEP-15:30 | 28897.12 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 45246.44 | 0.00 |
October | 102702.09 | 04-OCT-16:19 | 30883.85 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 39968.41 | 0.00 |
November | 85951.05 | 03-NOV-15:00 | 30883.85 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 23217.37 | 0.00 |
December | 69328.10 | 01-DEC-17:00 | 30883.85 | 10771.04 | 4644.36 | 0.00 | 22940.89 | 0.00 | 0.00 | 87.96 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 69328.10 | 26910.39 | 10771.04 | 0.00 | 0.00 | 21078.79 | 0.00 | 0.00 | 87.96 | 0.00 | |
Maximum of Months | 112999.56 | 30883.85 | 10771.04 | 4644.36 | 0.00 | 22940.89 | 0.00 | 0.00 | 54026.89 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 65797.86 | 27-JAN-07:30 | 0.00 | 5020.20 | 27-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 63029.58 | 03-FEB-07:30 | 0.00 | 5019.72 | 02-FEB-12:09 | 0.00 |
March | 0.00 | 0.00 | 50478.65 | 02-MAR-07:19 | 0.00 | 5005.06 | 01-MAR-12:39 | 0.00 |
April | 0.00 | 0.00 | 7971.89 | 11-APR-11:09 | 0.00 | 4961.97 | 03-APR-11:30 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 4916.16 | 01-MAY-11:09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 4866.90 | 01-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 4831.99 | 03-JUL-11:30 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 4833.68 | 31-AUG-11:09 | 0.00 |
September | 0.00 | 0.00 | 130.26 | 23-SEP-16:00 | 0.00 | 4866.42 | 29-SEP-11:09 | 0.00 |
October | 0.00 | 0.00 | 6587.16 | 24-OCT-11:09 | 0.00 | 4916.61 | 31-OCT-11:30 | 0.00 |
November | 0.00 | 0.00 | 47725.69 | 28-NOV-07:19 | 0.00 | 4965.75 | 30-NOV-12:30 | 0.00 |
December | 0.00 | 0.00 | 102036.76 | 27-DEC-07:10 | 0.00 | 5005.02 | 29-DEC-12:30 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4831.99 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 102036.76 | 0.00 | 5020.20 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 19.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.33 | 20.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.83 | 20.25 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 22.44 | 70.50 | 21.15 | 70.50 | 21.15 |
February | 376.00 | 22.89 | 50.17 | 21.15 | 50.17 | 21.15 |
March | 422.00 | 23.30 | 25.50 | 21.15 | 25.50 | 21.15 |
April | 295.67 | 23.79 | 10.67 | 23.89 | 0.00 | 0.00 |
May | 92.83 | 23.88 | 152.50 | 23.89 | 0.00 | 0.00 |
June | 5.17 | 23.89 | 314.83 | 23.89 | 1.17 | 23.89 |
July | 56.17 | 23.90 | 414.83 | 23.89 | 56.17 | 23.90 |
August | 32.33 | 23.90 | 410.50 | 23.89 | 32.33 | 23.90 |
September | 44.83 | 23.89 | 338.50 | 23.89 | 32.83 | 23.90 |
October | 151.67 | 23.85 | 130.33 | 23.89 | 12.17 | 23.89 |
November | 362.83 | 23.30 | 12.33 | 21.14 | 12.33 | 21.14 |
December | 415.00 | 22.34 | 102.33 | 21.14 | 102.33 | 21.14 |
Annual Sum or Average | 2668.50 | 23.10 | 2033.00 | 23.54 | 395.50 | 22.08 |
Minimum of Months | 5.17 | 22.34 | 10.67 | 21.14 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.90 | 414.83 | 23.89 | 102.33 | 23.90 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 410.33 | 23.03 | 6.00 | 21.11 | 6.00 | 21.11 |
February | 363.50 | 23.37 | 2.50 | 21.11 | 2.50 | 21.11 |
March | 367.00 | 23.56 | 0.67 | 21.11 | 0.67 | 21.11 |
April | 117.67 | 23.78 | 56.17 | 23.89 | 0.00 | 0.00 |
May | 18.83 | 23.88 | 237.83 | 23.89 | 0.00 | 0.00 |
June | 0.17 | 23.89 | 352.17 | 23.89 | 0.00 | 0.00 |
July | 43.33 | 23.90 | 414.50 | 23.89 | 43.33 | 23.90 |
August | 19.83 | 23.90 | 414.17 | 23.89 | 19.83 | 23.90 |
September | 29.33 | 23.89 | 360.33 | 23.89 | 27.00 | 23.90 |
October | 38.50 | 23.80 | 210.17 | 23.89 | 7.33 | 23.89 |
November | 289.17 | 23.42 | 26.00 | 23.88 | 0.00 | 0.00 |
December | 415.00 | 22.80 | 14.00 | 21.11 | 14.00 | 21.11 |
Annual Sum or Average | 2112.67 | 23.29 | 2094.50 | 23.86 | 120.67 | 23.36 |
Minimum of Months | 0.17 | 22.80 | 0.67 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 415.00 | 23.90 | 414.50 | 23.89 | 43.33 | 23.90 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 294.67 | 23.26 | 14.00 | 21.91 | 10.00 | 21.11 |
February | 272.17 | 23.42 | 7.50 | 21.11 | 7.50 | 21.11 |
March | 282.67 | 23.47 | 3.33 | 21.11 | 3.33 | 21.11 |
April | 138.83 | 23.74 | 61.00 | 23.89 | 0.00 | 0.00 |
May | 34.17 | 23.87 | 228.67 | 23.89 | 0.00 | 0.00 |
June | 2.17 | 23.86 | 359.33 | 23.89 | 0.00 | 0.00 |
July | 41.33 | 23.90 | 415.00 | 23.89 | 41.33 | 23.90 |
August | 24.17 | 23.90 | 420.67 | 23.89 | 24.17 | 23.90 |
September | 29.67 | 23.90 | 379.33 | 23.89 | 28.17 | 23.90 |
October | 21.67 | 23.84 | 303.67 | 23.89 | 5.33 | 23.89 |
November | 143.50 | 23.45 | 69.17 | 23.75 | 3.33 | 21.12 |
December | 316.00 | 23.22 | 14.00 | 21.11 | 14.00 | 21.11 |
Annual Sum or Average | 1601.00 | 23.43 | 2275.67 | 23.84 | 137.17 | 23.12 |
Minimum of Months | 2.17 | 23.22 | 3.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 316.00 | 23.90 | 420.67 | 23.89 | 41.33 | 23.90 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 348.17 | 22.70 | 22.83 | 21.11 | 22.83 | 21.11 |
February | 329.17 | 23.02 | 17.33 | 21.11 | 17.33 | 21.11 |
March | 378.33 | 23.20 | 17.67 | 21.11 | 17.67 | 21.11 |
April | 197.00 | 23.56 | 37.67 | 23.83 | 0.83 | 21.11 |
May | 66.17 | 23.80 | 185.50 | 23.89 | 0.00 | 0.00 |
June | 6.50 | 23.85 | 328.50 | 23.89 | 1.00 | 23.89 |
July | 52.00 | 23.90 | 414.17 | 23.89 | 52.00 | 23.90 |
August | 29.17 | 23.90 | 414.83 | 23.89 | 29.17 | 23.90 |
September | 33.83 | 23.88 | 368.67 | 23.89 | 29.33 | 23.90 |
October | 48.00 | 23.54 | 260.00 | 23.89 | 8.67 | 23.89 |
November | 195.83 | 22.93 | 48.50 | 23.44 | 7.83 | 21.11 |
December | 375.17 | 22.73 | 31.33 | 21.11 | 31.33 | 21.11 |
Annual Sum or Average | 2059.33 | 23.08 | 2147.00 | 23.76 | 218.00 | 22.65 |
Minimum of Months | 6.50 | 22.70 | 17.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 378.33 | 23.90 | 414.83 | 23.89 | 52.00 | 23.90 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.42236 | 26.32756 | -0.2752 | 7.75871 |
February | 376.00000 | 22.87046 | 21.94531 | -0.1911 | 6.99713 |
March | 422.00000 | 23.27909 | 19.19123 | -0.0851 | 6.18579 |
April | 405.00000 | 23.81601 | 23.19401 | 0.16822 | 6.01257 |
May | 418.00000 | 23.90625 | 32.44320 | -0.5567 | 11.79857 |
June | 408.00000 | 23.91248 | 38.09537 | -0.4278 | 8.95025 |
July | 415.00000 | 23.91397 | 50.11433 | -0.3333 | 7.38167 |
August | 422.00000 | 23.91260 | 46.97825 | -0.3736 | 7.99669 |
September | 405.00000 | 23.91060 | 45.32467 | -0.4216 | 8.90378 |
October | 414.00000 | 23.88536 | 37.56258 | 0.31782 | 7.35246 |
November | 399.00000 | 23.34008 | 24.71319 | -0.0090 | 6.14891 |
December | 415.00000 | 22.32899 | 23.80621 | -0.3127 | 8.35595 |
Annual Sum or Average | 4913.00000 | 23.46173 | 32.57018 | -0.2095 | 7.83251 |
Minimum of Months | 376.00000 | 22.32899 | 19.19123 | -0.5567 | 6.01257 |
Maximum of Months | 422.00000 | 23.91397 | 50.11433 | 0.31782 | 11.79857 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.04741 | 22.82585 | -0.0402 | 6.04591 |
February | 376.00000 | 23.38912 | 18.77058 | 0.03602 | 5.83601 |
March | 422.00000 | 23.60671 | 17.60148 | 0.11584 | 5.86156 |
April | 405.00000 | 23.87387 | 21.77281 | 0.28565 | 6.95610 |
May | 418.00000 | 23.91031 | 30.82238 | -0.4476 | 9.43920 |
June | 408.00000 | 23.91220 | 35.45338 | -0.3519 | 7.73887 |
July | 415.00000 | 23.91354 | 48.51160 | -0.2684 | 6.58588 |
August | 422.00000 | 23.91235 | 44.88279 | -0.3107 | 7.12670 |
September | 405.00000 | 23.91087 | 43.16978 | -0.3547 | 7.81644 |
October | 414.00000 | 23.89978 | 36.51683 | 0.39165 | 8.40266 |
November | 399.00000 | 23.56328 | 23.25102 | 0.14460 | 6.20961 |
December | 415.00000 | 22.81281 | 20.38762 | -0.1148 | 6.50735 |
Annual Sum or Average | 4913.00000 | 23.64750 | 30.43248 | -0.0780 | 7.05360 |
Minimum of Months | 376.00000 | 22.81281 | 17.60148 | -0.4476 | 5.83601 |
Maximum of Months | 422.00000 | 23.91354 | 48.51160 | 0.39165 | 9.43920 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 23.43042 | 20.42357 | 0.09838 | 6.44886 |
February | 376.00000 | 23.53849 | 17.31139 | 0.10872 | 6.30191 |
March | 422.00000 | 23.59716 | 16.60266 | 0.12194 | 6.22054 |
April | 405.00000 | 23.84727 | 21.22803 | 0.27365 | 7.00616 |
May | 418.00000 | 23.90570 | 30.10944 | -0.4609 | 9.79883 |
June | 408.00000 | 23.91112 | 34.97719 | -0.3451 | 7.64459 |
July | 415.00000 | 23.91306 | 47.03474 | -0.2469 | 6.35589 |
August | 422.00000 | 23.91217 | 43.76890 | -0.2648 | 6.58706 |
September | 405.00000 | 23.91054 | 41.79805 | -0.2659 | 6.73030 |
October | 414.00000 | 23.90298 | 35.44127 | 0.46840 | 9.84921 |
November | 399.00000 | 23.73678 | 21.73980 | 0.25721 | 7.20258 |
December | 415.00000 | 23.36520 | 17.86418 | 0.06174 | 6.45385 |
Annual Sum or Average | 4913.00000 | 23.74865 | 29.12745 | -0.0182 | 7.22364 |
Minimum of Months | 376.00000 | 23.36520 | 16.60266 | -0.4609 | 6.22054 |
Maximum of Months | 422.00000 | 23.91306 | 47.03474 | 0.46840 | 9.84921 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.88002 | 22.10419 | -0.0440 | 6.80543 |
February | 376.00000 | 23.11688 | 18.79790 | -0.0087 | 6.48619 |
March | 422.00000 | 23.25292 | 17.68249 | 0.01563 | 6.42946 |
April | 405.00000 | 23.73263 | 21.63966 | 0.21149 | 6.63119 |
May | 418.00000 | 23.88981 | 30.42879 | -0.5189 | 11.06994 |
June | 408.00000 | 23.91086 | 35.31951 | -0.3948 | 8.42047 |
July | 415.00000 | 23.91288 | 48.26649 | -0.2898 | 6.83380 |
August | 422.00000 | 23.91195 | 44.50101 | -0.3116 | 7.15394 |
September | 405.00000 | 23.90849 | 42.35810 | -0.3147 | 7.34390 |
October | 414.00000 | 23.86048 | 36.05533 | 0.42345 | 9.09218 |
November | 399.00000 | 23.41777 | 22.71802 | 0.15861 | 7.04447 |
December | 415.00000 | 22.83145 | 19.41689 | -0.0776 | 6.94684 |
Annual Sum or Average | 4913.00000 | 23.55483 | 30.04056 | -0.0977 | 7.53206 |
Minimum of Months | 376.00000 | 22.83145 | 17.68249 | -0.5189 | 6.42946 |
Maximum of Months | 422.00000 | 23.91288 | 48.26649 | 0.42345 | 11.06994 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 16756.72 | 4731.40 | 16.25 | 16754.37 | 2.35 | 0.00 | 0.00 | 03-JAN-15:00 | 0.00 | 01-JAN-00:10 | 1.39 | 03-JAN-15:00 | 1.39 | 03-JAN-15:00 | 0.00 | 02-JAN-15:10 | 0.39 | 03-JAN-15:00 | 0.00 | 01-JAN-00:10 |
February | 0.146256E+09 | 41256098.31 | 68.69 | 0.146256E+09 | 100.88 | 0.00 | 0.15 | 22-FEB-16:00 | 0.00 | 01-FEB-00:10 | 4153.29 | 22-FEB-16:00 | 4153.29 | 22-FEB-16:00 | 0.02 | 27-FEB-15:10 | 1162.81 | 22-FEB-16:00 | 0.00 | 01-FEB-00:10 |
March | 0.770630E+09 | 0.216480E+09 | 172.78 | 0.770628E+09 | 1285.37 | 0.00 | 0.26 | 22-MAR-14:10 | 0.00 | 01-MAR-00:10 | 7206.19 | 22-MAR-14:10 | 7206.19 | 22-MAR-14:10 | 0.11 | 11-MAR-16:10 | 2020.17 | 22-MAR-14:10 | 0.00 | 01-MAR-00:10 |
April | 0.702471E+10 | 0.202920E+10 | 307.78 | 0.698263E+10 | 42080704.32 | 0.00 | 1.00 | 20-APR-06:02 | 0.00 | 01-APR-00:10 | 35610.25 | 30-APR-08:62 | 35149.16 | 20-APR-06:02 | 4795.52 | 29-APR-06:02 | 7558.63 | 30-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.154329E+11 | 0.447334E+10 | 388.70 | 0.148677E+11 | 0.565149E+09 | 0.00 | 1.00 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 | 38304.54 | 28-MAY-08:62 | 35356.91 | 14-MAY-08:62 | 13595.96 | 25-MAY-06:02 | 8260.24 | 28-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.220894E+11 | 0.662914E+10 | 413.26 | 0.209741E+11 | 0.111528E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 38125.47 | 04-JUN-08:62 | 36026.54 | 08-JUN-06:02 | 14801.73 | 29-JUN-06:02 | 8569.91 | 18-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.267264E+11 | 0.755826E+10 | 426.84 | 0.219265E+11 | 0.479995E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 41170.34 | 22-JUL-06:02 | 36729.90 | 03-JUL-05:01 | 24485.58 | 19-JUL-06:04 | 8863.84 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.232306E+11 | 0.658420E+10 | 420.48 | 0.200608E+11 | 0.316972E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 40483.92 | 03-AUG-06:02 | 35683.48 | 27-AUG-08:62 | 19588.29 | 03-AUG-06:04 | 8722.90 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.189268E+11 | 0.526797E+10 | 383.05 | 0.162328E+11 | 0.269397E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 39878.81 | 22-SEP-06:02 | 31570.52 | 26-SEP-06:02 | 20102.20 | 22-SEP-06:04 | 8497.55 | 10-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.765451E+10 | 0.210465E+10 | 301.87 | 0.683929E+10 | 0.815218E+09 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 38397.03 | 04-OCT-06:02 | 34655.54 | 01-OCT-08:62 | 16595.09 | 04-OCT-06:02 | 8147.31 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.451468E+09 | 0.124344E+09 | 129.92 | 0.447929E+09 | 3539267.88 | 0.00 | 0.29 | 03-NOV-16:00 | 0.00 | 01-NOV-00:10 | 8497.08 | 03-NOV-16:00 | 8497.08 | 03-NOV-16:00 | 416.61 | 03-NOV-12:50 | 2341.34 | 03-NOV-16:00 | 0.00 | 01-NOV-00:10 |
December | 16181.01 | 4567.66 | 20.17 | 16181.01 | 0.00 | 0.00 | 0.00 | 09-DEC-13:00 | 0.00 | 01-DEC-00:10 | 0.71 | 09-DEC-13:00 | 0.71 | 09-DEC-13:00 | 0.00 | 09-DEC-14:20 | 0.20 | 09-DEC-13:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.122454E+12 | 0.350289E+11 | 3049.78 | 0.109249E+12 | 0.132049E+11 | 0.00 | ||||||||||||||
Minimum of Months | 16181.01 | 4567.66 | 16.25 | 16181.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.71 | 0.71 | 0.00 | 0.20 | 0.00 | |||||||
Maximum of Months | 0.267264E+11 | 0.755826E+10 | 426.84 | 0.219265E+11 | 0.479995E+10 | 0.00 | 1.00 | 0.00 | 41170.34 | 36729.90 | 24485.58 | 8863.84 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.229002E+09 | 70892206.71 | 92.64 | 0.228041E+09 | 961794.45 | 0.00 | 0.11 | 03-JAN-15:10 | 0.00 | 01-JAN-00:10 | 14529.07 | 03-JAN-15:10 | 14529.07 | 03-JAN-15:10 | 169.88 | 12-JAN-16:00 | 4453.36 | 03-JAN-15:10 | 0.00 | 01-JAN-00:10 |
February | 0.348167E+10 | 0.106613E+10 | 163.04 | 0.348020E+10 | 1465055.87 | 0.00 | 0.47 | 08-FEB-07:03 | 0.00 | 01-FEB-00:10 | 66123.36 | 08-FEB-07:03 | 57622.70 | 08-FEB-07:03 | 8500.66 | 08-FEB-07:03 | 18412.45 | 08-FEB-07:03 | 0.00 | 01-FEB-00:10 |
March | 0.107923E+11 | 0.328370E+10 | 246.27 | 0.107878E+11 | 4475903.43 | 0.00 | 0.97 | 10-MAR-07:02 | 0.00 | 01-MAR-00:10 | 159069.92 | 10-MAR-07:02 | 159069.92 | 10-MAR-07:02 | 27984.98 | 11-MAR-07:03 | 38023.72 | 10-MAR-07:02 | 0.00 | 01-MAR-00:10 |
April | 0.473369E+11 | 0.148416E+11 | 341.65 | 0.468378E+11 | 0.499122E+09 | 0.00 | 1.00 | 02-APR-08:62 | 0.00 | 01-APR-00:10 | 168811.81 | 30-APR-08:62 | 165838.69 | 02-APR-08:62 | 31537.48 | 18-APR-06:02 | 40073.95 | 30-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.850307E+11 | 0.270924E+11 | 412.27 | 0.815393E+11 | 0.349134E+10 | 0.00 | 1.00 | 01-MAY-06:02 | 0.00 | 01-MAY-00:10 | 181321.84 | 28-MAY-08:62 | 166488.62 | 14-MAY-08:62 | 64323.27 | 25-MAY-06:02 | 43657.98 | 28-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.112343E+12 | 0.373223E+11 | 422.06 | 0.105777E+12 | 0.656609E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 180585.02 | 04-JUN-08:62 | 169185.10 | 08-JUN-06:02 | 68529.49 | 29-JUN-06:02 | 45251.81 | 18-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.132966E+12 | 0.415981E+11 | 431.19 | 0.106204E+12 | 0.267615E+11 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 194602.94 | 22-JUL-06:02 | 170780.24 | 03-JUL-05:01 | 111998.94 | 19-JUL-06:04 | 46651.25 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.115600E+12 | 0.363419E+11 | 430.29 | 0.977531E+11 | 0.178471E+11 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 191600.50 | 03-AUG-06:02 | 167468.19 | 27-AUG-08:62 | 93552.63 | 03-AUG-06:04 | 45854.57 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.957937E+11 | 0.295609E+11 | 390.93 | 0.806836E+11 | 0.151101E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 188329.38 | 22-SEP-06:02 | 142359.68 | 26-SEP-06:02 | 93369.00 | 22-SEP-06:04 | 44854.64 | 10-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.464187E+11 | 0.140374E+11 | 338.91 | 0.407430E+11 | 0.567569E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 181408.44 | 04-OCT-06:02 | 163158.83 | 31-OCT-06:02 | 78072.60 | 04-OCT-06:02 | 43004.96 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.634362E+10 | 0.190924E+10 | 183.33 | 0.612906E+10 | 0.214552E+09 | 0.00 | 1.00 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 | 165838.69 | 01-NOV-06:02 | 165838.69 | 09-NOV-07:02 | 48892.49 | 02-NOV-06:02 | 39237.21 | 01-NOV-06:02 | 0.00 | 01-NOV-00:10 |
December | 1561736.50 | 492460.67 | 62.74 | 1560846.29 | 890.20 | 0.00 | 0.00 | 19-DEC-16:00 | 0.00 | 01-DEC-00:10 | 375.00 | 19-DEC-16:00 | 375.00 | 19-DEC-16:00 | 0.16 | 04-DEC-15:10 | 118.21 | 19-DEC-16:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.656337E+12 | 0.207125E+12 | 3515.33 | 0.580165E+12 | 0.761724E+11 | 0.00 | ||||||||||||||
Minimum of Months | 1561736.50 | 492460.67 | 62.74 | 1560846.29 | 890.20 | 0.00 | 0.00 | 0.00 | 375.00 | 375.00 | 0.16 | 118.21 | 0.00 | |||||||
Maximum of Months | 0.132966E+12 | 0.415981E+11 | 431.19 | 0.106204E+12 | 0.267615E+11 | 0.00 | 1.00 | 0.00 | 194602.94 | 170780.24 | 111998.94 | 46651.25 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.171012E+09 | 46143712.56 | 152.50 | 0.170420E+09 | 591331.63 | 0.00 | 0.27 | 03-JAN-14:40 | 0.00 | 01-JAN-00:10 | 4962.95 | 03-JAN-14:40 | 4962.95 | 03-JAN-14:40 | 63.59 | 02-JAN-14:10 | 1306.53 | 03-JAN-14:40 | 0.00 | 01-JAN-00:10 |
February | 0.974845E+09 | 0.259970E+09 | 197.59 | 0.974843E+09 | 1144.77 | 0.00 | 0.39 | 21-FEB-15:10 | 0.00 | 01-FEB-00:10 | 7375.55 | 21-FEB-15:10 | 7375.55 | 21-FEB-15:10 | 0.10 | 13-FEB-12:15 | 1937.19 | 21-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.184071E+10 | 0.495309E+09 | 251.25 | 0.184071E+10 | 2113.42 | 0.00 | 0.46 | 22-MAR-13:00 | 0.00 | 01-MAR-00:10 | 8737.44 | 22-MAR-13:10 | 8737.44 | 22-MAR-13:10 | 0.15 | 11-MAR-12:50 | 2349.55 | 22-MAR-13:00 | 0.00 | 01-MAR-00:10 |
April | 0.639161E+10 | 0.179593E+10 | 326.30 | 0.634488E+10 | 46732559.85 | 0.00 | 1.00 | 20-APR-06:02 | 0.00 | 01-APR-00:10 | 23210.77 | 30-APR-08:62 | 22884.93 | 20-APR-06:02 | 3832.90 | 29-APR-06:02 | 4927.64 | 30-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.109799E+11 | 0.315869E+10 | 394.74 | 0.105942E+11 | 0.385664E+09 | 0.00 | 1.00 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 | 24952.10 | 28-MAY-08:62 | 22909.37 | 14-MAY-08:62 | 9159.09 | 25-MAY-06:02 | 5380.10 | 28-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.146056E+11 | 0.438975E+10 | 416.75 | 0.138689E+11 | 0.736765E+09 | 0.00 | 1.00 | 02-JUN-06:02 | 0.00 | 01-JUN-00:10 | 24830.95 | 04-JUN-08:62 | 23293.31 | 08-JUN-06:02 | 10028.37 | 29-JUN-06:02 | 5578.65 | 18-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.176013E+11 | 0.498911E+10 | 428.32 | 0.144596E+11 | 0.314170E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 26838.96 | 22-JUL-06:02 | 23022.97 | 03-JUL-05:03 | 16207.25 | 19-JUL-06:02 | 5765.93 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.161575E+11 | 0.455558E+10 | 428.52 | 0.139935E+11 | 0.216406E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 26403.51 | 03-AUG-06:02 | 23059.31 | 27-AUG-08:62 | 13249.04 | 03-AUG-06:02 | 5670.14 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.147548E+11 | 0.403023E+10 | 393.03 | 0.128314E+11 | 0.192336E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 26027.80 | 22-SEP-06:02 | 19595.52 | 26-SEP-06:02 | 13555.32 | 22-SEP-06:02 | 5528.11 | 10-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.858010E+10 | 0.226057E+10 | 346.40 | 0.773966E+10 | 0.840444E+09 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 24976.64 | 04-OCT-06:02 | 22113.95 | 02-OCT-05:02 | 11061.66 | 04-OCT-06:02 | 5302.09 | 02-OCT-05:02 | 0.00 | 01-OCT-00:10 |
November | 0.198745E+10 | 0.521382E+09 | 223.89 | 0.193939E+10 | 48061953.14 | 0.00 | 0.98 | 10-NOV-07:02 | 0.00 | 01-NOV-00:10 | 22342.54 | 10-NOV-07:02 | 19979.51 | 10-NOV-07:02 | 5697.22 | 01-NOV-06:02 | 4758.44 | 10-NOV-07:02 | 0.00 | 01-NOV-00:10 |
December | 39305813.80 | 10904172.63 | 118.47 | 39305664.17 | 149.63 | 0.00 | 0.12 | 23-DEC-15:00 | 0.00 | 01-DEC-00:10 | 2138.77 | 23-DEC-15:00 | 2138.77 | 23-DEC-15:00 | 0.02 | 04-DEC-15:10 | 585.51 | 23-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.940842E+11 | 0.265136E+11 | 3677.76 | 0.847968E+11 | 0.928739E+10 | 0.00 | ||||||||||||||
Minimum of Months | 39305813.80 | 10904172.63 | 118.47 | 39305664.17 | 149.63 | 0.00 | 0.12 | 0.00 | 2138.77 | 2138.77 | 0.02 | 585.51 | 0.00 | |||||||
Maximum of Months | 0.176013E+11 | 0.498911E+10 | 428.52 | 0.144596E+11 | 0.314170E+10 | 0.00 | 1.00 | 0.00 | 26838.96 | 23293.31 | 16207.25 | 5765.93 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 75920440.09 | 20646150.96 | 89.39 | 75453911.27 | 466528.82 | 0.00 | 0.21 | 03-JAN-14:30 | 0.00 | 01-JAN-00:10 | 3099.92 | 03-JAN-14:30 | 3099.92 | 03-JAN-14:30 | 37.33 | 12-JAN-16:10 | 828.91 | 03-JAN-14:30 | 0.00 | 01-JAN-00:10 |
February | 0.542033E+09 | 0.146215E+09 | 139.26 | 0.542032E+09 | 369.74 | 0.00 | 0.34 | 21-FEB-15:10 | 0.00 | 01-FEB-00:10 | 5115.60 | 21-FEB-15:10 | 5115.60 | 21-FEB-15:10 | 0.04 | 27-FEB-12:40 | 1362.89 | 21-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.967043E+09 | 0.264128E+09 | 202.65 | 0.967042E+09 | 1026.38 | 0.00 | 0.40 | 22-MAR-13:10 | 0.00 | 01-MAR-00:10 | 6070.82 | 22-MAR-13:10 | 6070.82 | 22-MAR-13:10 | 0.08 | 11-MAR-13:30 | 1658.24 | 22-MAR-13:00 | 0.00 | 01-MAR-00:10 |
April | 0.429333E+10 | 0.122620E+10 | 300.68 | 0.425693E+10 | 36398929.01 | 0.00 | 1.00 | 20-APR-06:02 | 0.00 | 01-APR-00:10 | 18803.07 | 30-APR-08:62 | 18560.39 | 20-APR-06:02 | 3249.52 | 29-APR-06:02 | 3991.11 | 30-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.797962E+10 | 0.232242E+10 | 382.35 | 0.765888E+10 | 0.320741E+09 | 0.00 | 1.00 | 09-MAY-06:02 | 0.00 | 01-MAY-00:10 | 20230.47 | 28-MAY-08:62 | 18560.39 | 10-MAY-06:02 | 6602.49 | 24-MAY-06:02 | 4362.41 | 28-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.113050E+11 | 0.342035E+10 | 408.22 | 0.106861E+11 | 0.618922E+09 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 20136.67 | 04-JUN-08:62 | 18848.86 | 08-JUN-06:02 | 8267.84 | 29-JUN-06:02 | 4526.18 | 18-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.138553E+11 | 0.393748E+10 | 425.15 | 0.111628E+11 | 0.269242E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 21738.53 | 22-JUL-06:02 | 19259.50 | 03-JUL-05:01 | 13051.79 | 19-JUL-06:02 | 4683.06 | 02-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.125763E+11 | 0.356175E+10 | 419.15 | 0.107614E+11 | 0.181484E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 21396.67 | 03-AUG-06:02 | 18669.85 | 27-AUG-08:62 | 10799.29 | 03-AUG-06:04 | 4591.92 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.115169E+11 | 0.315664E+10 | 386.79 | 0.986614E+10 | 0.165071E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 21080.01 | 22-SEP-06:02 | 15800.58 | 26-SEP-06:02 | 10943.54 | 22-SEP-06:02 | 4485.85 | 10-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.633096E+10 | 0.167743E+10 | 324.59 | 0.566984E+10 | 0.661113E+09 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 20270.96 | 04-OCT-06:02 | 17536.53 | 02-OCT-05:02 | 9117.00 | 04-OCT-06:02 | 4301.40 | 04-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.129643E+10 | 0.341683E+09 | 187.98 | 0.126163E+10 | 34800626.29 | 0.00 | 0.99 | 11-NOV-09:02 | 0.00 | 01-NOV-00:10 | 18237.83 | 11-NOV-09:02 | 16063.23 | 11-NOV-09:02 | 3463.86 | 01-NOV-06:02 | 3878.06 | 11-NOV-09:02 | 0.00 | 01-NOV-00:10 |
December | 3880060.16 | 1086581.86 | 76.10 | 3879974.62 | 85.54 | 0.00 | 0.05 | 23-DEC-15:00 | 0.00 | 01-DEC-00:10 | 695.80 | 23-DEC-15:00 | 695.80 | 23-DEC-15:00 | 0.02 | 04-DEC-15:10 | 193.99 | 23-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.707426E+11 | 0.200760E+11 | 3342.32 | 0.629122E+11 | 0.783042E+10 | 0.00 | ||||||||||||||
Minimum of Months | 3880060.16 | 1086581.86 | 76.10 | 3879974.62 | 85.54 | 0.00 | 0.05 | 0.00 | 695.80 | 695.80 | 0.02 | 193.99 | 0.00 | |||||||
Maximum of Months | 0.138553E+11 | 0.393748E+10 | 425.15 | 0.111628E+11 | 0.269242E+10 | 0.00 | 1.00 | 0.00 | 21738.53 | 19259.50 | 13051.79 | 4683.06 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 80.60 | 56.27 | 24.33 | 85.53 | 74.44 | 0.00 | 0.00 | 744.00 |
February | 106.43 | 75.90 | 30.53 | 119.37 | 69.42 | 0.00 | 0.00 | 672.00 |
March | 144.14 | 101.30 | 42.83 | 171.07 | 61.36 | 0.00 | 0.00 | 744.00 |
April | 181.83 | 134.96 | 46.86 | 230.89 | 43.19 | 0.00 | 0.00 | 720.00 |
May | 199.62 | 148.24 | 51.38 | 264.65 | 32.42 | 0.00 | 0.00 | 744.00 |
June | 210.95 | 163.51 | 47.44 | 290.82 | 21.39 | 0.00 | 0.00 | 720.00 |
July | 182.71 | 131.69 | 51.02 | 254.70 | 16.42 | 0.00 | 0.00 | 744.00 |
August | 169.98 | 122.33 | 47.65 | 233.70 | 20.76 | 0.00 | 0.00 | 744.00 |
September | 156.79 | 117.33 | 39.46 | 211.78 | 31.91 | 0.00 | 0.00 | 720.00 |
October | 118.16 | 85.86 | 32.30 | 148.75 | 45.08 | 0.00 | 0.00 | 744.00 |
November | 93.60 | 69.80 | 23.80 | 104.59 | 68.50 | 0.00 | 0.00 | 720.00 |
December | 75.52 | 50.29 | 25.24 | 76.61 | 82.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 143.47 | 104.85 | 38.63 | 182.93 | 47.15 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 75.52 | 50.29 | 23.80 | 76.61 | 16.42 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 210.95 | 163.51 | 51.38 | 290.82 | 82.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1151.11 | 872.17 | 278.94 | 1495.50 | 880.37 | 0.00 | 0.00 | 744.00 |
February | 1067.68 | 752.76 | 314.92 | 1363.36 | 790.40 | 0.00 | 0.00 | 672.00 |
March | 867.33 | 500.02 | 367.32 | 1046.97 | 698.79 | 0.00 | 0.00 | 744.00 |
April | 587.92 | 219.20 | 368.72 | 708.92 | 440.76 | 0.00 | 0.00 | 720.00 |
May | 415.40 | 57.91 | 357.48 | 577.17 | 273.47 | 0.00 | 0.00 | 744.00 |
June | 358.38 | 22.52 | 335.86 | 668.98 | 154.74 | 0.00 | 0.00 | 720.00 |
July | 365.35 | 33.67 | 331.68 | 670.47 | 132.14 | 0.00 | 0.00 | 744.00 |
August | 465.76 | 123.12 | 342.64 | 754.26 | 182.89 | 0.00 | 0.00 | 744.00 |
September | 727.11 | 377.63 | 349.48 | 1120.31 | 333.11 | 0.00 | 0.00 | 720.00 |
October | 988.31 | 668.17 | 320.14 | 1422.23 | 501.69 | 0.00 | 0.00 | 744.00 |
November | 1189.65 | 907.04 | 282.61 | 1587.39 | 776.93 | 0.00 | 0.00 | 720.00 |
December | 1178.96 | 885.06 | 293.90 | 1502.75 | 948.72 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 778.59 | 449.90 | 328.69 | 1074.77 | 508.10 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 358.38 | 22.52 | 278.94 | 577.17 | 132.14 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1189.65 | 907.04 | 368.72 | 1587.39 | 948.72 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1151.11 | 872.17 | 278.94 | 1504.49 | 844.99 | 0.00 | 0.00 | 744.00 |
February | 1067.68 | 752.76 | 314.92 | 1370.65 | 760.43 | 0.00 | 0.00 | 672.00 |
March | 867.33 | 500.02 | 367.32 | 1053.98 | 672.45 | 0.00 | 0.00 | 744.00 |
April | 587.92 | 219.20 | 368.72 | 709.57 | 420.95 | 0.00 | 0.00 | 720.00 |
May | 415.40 | 57.91 | 357.48 | 575.39 | 257.62 | 0.00 | 0.00 | 744.00 |
June | 358.38 | 22.52 | 335.86 | 667.06 | 141.76 | 0.00 | 0.00 | 720.00 |
July | 365.35 | 33.67 | 331.68 | 668.46 | 119.40 | 0.00 | 0.00 | 744.00 |
August | 465.76 | 123.12 | 342.64 | 751.13 | 169.40 | 0.00 | 0.00 | 744.00 |
September | 727.11 | 377.63 | 349.48 | 1116.58 | 318.57 | 0.00 | 0.00 | 720.00 |
October | 988.31 | 668.17 | 320.14 | 1420.84 | 484.86 | 0.00 | 0.00 | 744.00 |
November | 1189.65 | 907.04 | 282.61 | 1592.35 | 752.59 | 0.00 | 0.00 | 720.00 |
December | 1178.96 | 885.06 | 293.90 | 1512.62 | 914.62 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 778.59 | 449.90 | 328.69 | 1076.82 | 486.77 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 358.38 | 22.52 | 278.94 | 575.39 | 119.40 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1189.65 | 907.04 | 368.72 | 1592.35 | 914.62 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 236.86 | 179.46 | 57.40 | 307.43 | 167.24 | 0.00 | 0.00 | 744.00 |
February | 219.69 | 154.89 | 64.80 | 280.42 | 149.77 | 0.00 | 0.00 | 672.00 |
March | 178.47 | 102.89 | 75.58 | 216.35 | 132.01 | 0.00 | 0.00 | 744.00 |
April | 120.97 | 45.10 | 75.87 | 140.61 | 85.09 | 0.00 | 0.00 | 720.00 |
May | 85.47 | 11.92 | 73.56 | 103.19 | 55.67 | 0.00 | 0.00 | 744.00 |
June | 73.74 | 4.63 | 69.11 | 104.79 | 34.94 | 0.00 | 0.00 | 720.00 |
July | 75.18 | 6.93 | 68.25 | 107.59 | 30.35 | 0.00 | 0.00 | 744.00 |
August | 95.84 | 25.33 | 70.50 | 129.46 | 41.38 | 0.00 | 0.00 | 744.00 |
September | 149.61 | 77.70 | 71.91 | 209.83 | 72.79 | 0.00 | 0.00 | 720.00 |
October | 203.36 | 137.49 | 65.87 | 285.79 | 99.25 | 0.00 | 0.00 | 744.00 |
November | 244.79 | 186.64 | 58.15 | 326.54 | 147.49 | 0.00 | 0.00 | 720.00 |
December | 242.59 | 182.11 | 60.47 | 309.03 | 181.06 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 160.21 | 92.57 | 67.63 | 209.67 | 99.50 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 73.74 | 4.63 | 57.40 | 103.19 | 30.35 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 244.79 | 186.64 | 75.87 | 326.54 | 181.06 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.215875E+09 | 0.150718E+09 | 65157652.35 | 0.229086E+09 | 0.199384E+09 |
February | 0.257484E+09 | 0.183618E+09 | 73866000.70 | 0.288771E+09 | 0.167940E+09 |
March | 0.386060E+09 | 0.271333E+09 | 0.114727E+09 | 0.458195E+09 | 0.164352E+09 |
April | 0.471292E+09 | 0.349827E+09 | 0.121465E+09 | 0.598477E+09 | 0.111947E+09 |
May | 0.534660E+09 | 0.397050E+09 | 0.137610E+09 | 0.708844E+09 | 86840438.35 |
June | 0.546784E+09 | 0.423808E+09 | 0.122976E+09 | 0.753806E+09 | 55447957.12 |
July | 0.489379E+09 | 0.352715E+09 | 0.136664E+09 | 0.682186E+09 | 43971113.12 |
August | 0.455287E+09 | 0.327648E+09 | 0.127639E+09 | 0.625951E+09 | 55593275.04 |
September | 0.406395E+09 | 0.304124E+09 | 0.102272E+09 | 0.548926E+09 | 82702247.13 |
October | 0.316481E+09 | 0.229972E+09 | 86508825.75 | 0.398406E+09 | 0.120744E+09 |
November | 0.242615E+09 | 0.180920E+09 | 61695043.00 | 0.271089E+09 | 0.177563E+09 |
December | 0.202285E+09 | 0.134696E+09 | 67589438.91 | 0.205184E+09 | 0.220459E+09 |
Annual Sum or Average | 0.452460E+10 | 0.330643E+10 | 0.121817E+10 | 0.576892E+10 | 0.148694E+10 |
Minimum of Months | 0.202285E+09 | 0.134696E+09 | 61695043.00 | 0.205184E+09 | 43971113.12 |
Maximum of Months | 0.546784E+09 | 0.423808E+09 | 0.137610E+09 | 0.753806E+09 | 0.220459E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.308312E+10 | 0.233601E+10 | 0.747113E+09 | 0.400555E+10 | 0.235798E+10 |
February | 0.258293E+10 | 0.182108E+10 | 0.761849E+09 | 0.329824E+10 | 0.191213E+10 |
March | 0.232306E+10 | 0.133924E+10 | 0.983820E+09 | 0.280421E+10 | 0.187164E+10 |
April | 0.152388E+10 | 0.568166E+09 | 0.955718E+09 | 0.183752E+10 | 0.114245E+10 |
May | 0.111259E+10 | 0.155108E+09 | 0.957486E+09 | 0.154590E+10 | 0.732470E+09 |
June | 0.928918E+09 | 58371560.74 | 0.870547E+09 | 0.173400E+10 | 0.401082E+09 |
July | 0.978548E+09 | 90181383.78 | 0.888366E+09 | 0.179578E+10 | 0.353916E+09 |
August | 0.124750E+10 | 0.329757E+09 | 0.917739E+09 | 0.202021E+10 | 0.489843E+09 |
September | 0.188467E+10 | 0.978830E+09 | 0.905839E+09 | 0.290384E+10 | 0.863409E+09 |
October | 0.264708E+10 | 0.178962E+10 | 0.857453E+09 | 0.380930E+10 | 0.134374E+10 |
November | 0.308356E+10 | 0.235105E+10 | 0.732514E+09 | 0.411453E+10 | 0.201380E+10 |
December | 0.315772E+10 | 0.237054E+10 | 0.787183E+09 | 0.402497E+10 | 0.254104E+10 |
Annual Sum or Average | 0.245536E+11 | 0.141880E+11 | 0.103656E+11 | 0.338940E+11 | 0.160235E+11 |
Minimum of Months | 0.928918E+09 | 58371560.74 | 0.732514E+09 | 0.154590E+10 | 0.353916E+09 |
Maximum of Months | 0.315772E+10 | 0.237054E+10 | 0.983820E+09 | 0.411453E+10 | 0.254104E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.308312E+10 | 0.233601E+10 | 0.747113E+09 | 0.402962E+10 | 0.226323E+10 |
February | 0.258293E+10 | 0.182108E+10 | 0.761849E+09 | 0.331588E+10 | 0.183963E+10 |
March | 0.232306E+10 | 0.133924E+10 | 0.983820E+09 | 0.282297E+10 | 0.180110E+10 |
April | 0.152388E+10 | 0.568166E+09 | 0.955718E+09 | 0.183921E+10 | 0.109111E+10 |
May | 0.111259E+10 | 0.155108E+09 | 0.957486E+09 | 0.154112E+10 | 0.690021E+09 |
June | 0.928918E+09 | 58371560.74 | 0.870547E+09 | 0.172903E+10 | 0.367444E+09 |
July | 0.978548E+09 | 90181383.78 | 0.888366E+09 | 0.179040E+10 | 0.319803E+09 |
August | 0.124750E+10 | 0.329757E+09 | 0.917739E+09 | 0.201184E+10 | 0.453714E+09 |
September | 0.188467E+10 | 0.978830E+09 | 0.905839E+09 | 0.289417E+10 | 0.825728E+09 |
October | 0.264708E+10 | 0.178962E+10 | 0.857453E+09 | 0.380558E+10 | 0.129865E+10 |
November | 0.308356E+10 | 0.235105E+10 | 0.732514E+09 | 0.412738E+10 | 0.195071E+10 |
December | 0.315772E+10 | 0.237054E+10 | 0.787183E+09 | 0.405140E+10 | 0.244973E+10 |
Annual Sum or Average | 0.245536E+11 | 0.141880E+11 | 0.103656E+11 | 0.339586E+11 | 0.153509E+11 |
Minimum of Months | 0.928918E+09 | 58371560.74 | 0.732514E+09 | 0.154112E+10 | 0.319803E+09 |
Maximum of Months | 0.315772E+10 | 0.237054E+10 | 0.983820E+09 | 0.412738E+10 | 0.244973E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.634397E+09 | 0.480668E+09 | 0.153729E+09 | 0.823410E+09 | 0.447948E+09 |
February | 0.531474E+09 | 0.374713E+09 | 0.156762E+09 | 0.678397E+09 | 0.362332E+09 |
March | 0.478004E+09 | 0.275569E+09 | 0.202435E+09 | 0.579469E+09 | 0.353569E+09 |
April | 0.313561E+09 | 0.116908E+09 | 0.196653E+09 | 0.364458E+09 | 0.220563E+09 |
May | 0.228933E+09 | 31915771.26 | 0.197017E+09 | 0.276376E+09 | 0.149115E+09 |
June | 0.191138E+09 | 12010798.58 | 0.179128E+09 | 0.271610E+09 | 90564598.98 |
July | 0.201350E+09 | 18556132.86 | 0.182794E+09 | 0.288160E+09 | 81300697.19 |
August | 0.256691E+09 | 67852387.83 | 0.188838E+09 | 0.346742E+09 | 0.110828E+09 |
September | 0.387798E+09 | 0.201408E+09 | 0.186390E+09 | 0.543892E+09 | 0.188661E+09 |
October | 0.544675E+09 | 0.368241E+09 | 0.176434E+09 | 0.765473E+09 | 0.265820E+09 |
November | 0.634488E+09 | 0.483763E+09 | 0.150725E+09 | 0.846393E+09 | 0.382289E+09 |
December | 0.649747E+09 | 0.487773E+09 | 0.161974E+09 | 0.827717E+09 | 0.484953E+09 |
Annual Sum or Average | 0.505226E+10 | 0.291938E+10 | 0.213288E+10 | 0.661210E+10 | 0.313794E+10 |
Minimum of Months | 0.191138E+09 | 12010798.58 | 0.150725E+09 | 0.271610E+09 | 81300697.19 |
Maximum of Months | 0.649747E+09 | 0.487773E+09 | 0.202435E+09 | 0.846393E+09 | 0.484953E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1368.50 | 1191.06 | 1289.58 | 900.34 | 389.23 | 0.00 | 0.00 |
February | 1909.86 | 1110.71 | 1702.94 | 1214.41 | 488.53 | 0.00 | 0.00 |
March | 2737.13 | 981.79 | 2306.21 | 1620.87 | 685.34 | 0.00 | 0.00 |
April | 3694.31 | 691.03 | 2909.21 | 2159.42 | 749.78 | 0.00 | 0.00 |
May | 4234.43 | 518.76 | 3193.91 | 2371.86 | 822.04 | 0.00 | 0.00 |
June | 4653.13 | 342.27 | 3375.21 | 2616.10 | 759.11 | 0.00 | 0.00 |
July | 4075.19 | 262.67 | 2923.41 | 2107.02 | 816.39 | 0.00 | 0.00 |
August | 3739.25 | 332.10 | 2719.76 | 1957.28 | 762.48 | 0.00 | 0.00 |
September | 3388.43 | 510.51 | 2508.61 | 1877.31 | 631.31 | 0.00 | 0.00 |
October | 2379.97 | 721.29 | 1890.57 | 1373.79 | 516.78 | 0.00 | 0.00 |
November | 1673.39 | 1096.07 | 1497.62 | 1116.79 | 380.83 | 0.00 | 0.00 |
December | 1225.71 | 1316.96 | 1208.40 | 804.64 | 403.76 | 0.00 | 0.00 |
Annual Sum or Average | 2926.90 | 754.41 | 2295.59 | 1677.54 | 618.05 | 0.00 | 0.00 |
Minimum of Months | 1225.71 | 262.67 | 1208.40 | 804.64 | 380.83 | 0.00 | 0.00 |
Maximum of Months | 4653.13 | 1316.96 | 3375.21 | 2616.10 | 822.04 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1495.50 | 880.37 | 1151.11 | 872.17 | 278.94 | 0.00 | 0.00 |
February | 1363.36 | 790.40 | 1067.68 | 752.76 | 314.92 | 0.00 | 0.00 |
March | 1046.97 | 698.79 | 867.33 | 500.02 | 367.32 | 0.00 | 0.00 |
April | 708.92 | 440.76 | 587.92 | 219.20 | 368.72 | 0.00 | 0.00 |
May | 577.17 | 273.47 | 415.40 | 57.91 | 357.48 | 0.00 | 0.00 |
June | 668.98 | 154.74 | 358.38 | 22.52 | 335.86 | 0.00 | 0.00 |
July | 670.47 | 132.14 | 365.35 | 33.67 | 331.68 | 0.00 | 0.00 |
August | 754.26 | 182.89 | 465.76 | 123.12 | 342.64 | 0.00 | 0.00 |
September | 1120.31 | 333.11 | 727.11 | 377.63 | 349.48 | 0.00 | 0.00 |
October | 1422.23 | 501.69 | 988.31 | 668.17 | 320.14 | 0.00 | 0.00 |
November | 1587.39 | 776.93 | 1189.65 | 907.04 | 282.61 | 0.00 | 0.00 |
December | 1502.75 | 948.72 | 1178.96 | 885.06 | 293.90 | 0.00 | 0.00 |
Annual Sum or Average | 1074.77 | 508.10 | 778.59 | 449.90 | 328.69 | 0.00 | 0.00 |
Minimum of Months | 577.17 | 132.14 | 358.38 | 22.52 | 278.94 | 0.00 | 0.00 |
Maximum of Months | 1587.39 | 948.72 | 1189.65 | 907.04 | 368.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 1504.49 | 844.99 | 1151.11 | 872.17 | 278.94 | 0.00 | 0.00 |
February | 1370.65 | 760.43 | 1067.68 | 752.76 | 314.92 | 0.00 | 0.00 |
March | 1053.98 | 672.45 | 867.33 | 500.02 | 367.32 | 0.00 | 0.00 |
April | 709.57 | 420.95 | 587.92 | 219.20 | 368.72 | 0.00 | 0.00 |
May | 575.39 | 257.62 | 415.40 | 57.91 | 357.48 | 0.00 | 0.00 |
June | 667.06 | 141.76 | 358.38 | 22.52 | 335.86 | 0.00 | 0.00 |
July | 668.46 | 119.40 | 365.35 | 33.67 | 331.68 | 0.00 | 0.00 |
August | 751.13 | 169.40 | 465.76 | 123.12 | 342.64 | 0.00 | 0.00 |
September | 1116.58 | 318.57 | 727.11 | 377.63 | 349.48 | 0.00 | 0.00 |
October | 1420.84 | 484.86 | 988.31 | 668.17 | 320.14 | 0.00 | 0.00 |
November | 1592.35 | 752.59 | 1189.65 | 907.04 | 282.61 | 0.00 | 0.00 |
December | 1512.62 | 914.62 | 1178.96 | 885.06 | 293.90 | 0.00 | 0.00 |
Annual Sum or Average | 1076.82 | 486.77 | 778.59 | 449.90 | 328.69 | 0.00 | 0.00 |
Minimum of Months | 575.39 | 119.40 | 358.38 | 22.52 | 278.94 | 0.00 | 0.00 |
Maximum of Months | 1592.35 | 914.62 | 1189.65 | 907.04 | 368.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 307.43 | 167.24 | 236.86 | 179.46 | 57.40 | 0.00 | 0.00 |
February | 280.42 | 149.77 | 219.69 | 154.89 | 64.80 | 0.00 | 0.00 |
March | 216.35 | 132.01 | 178.47 | 102.89 | 75.58 | 0.00 | 0.00 |
April | 140.61 | 85.09 | 120.97 | 45.10 | 75.87 | 0.00 | 0.00 |
May | 103.19 | 55.67 | 85.47 | 11.92 | 73.56 | 0.00 | 0.00 |
June | 104.79 | 34.94 | 73.74 | 4.63 | 69.11 | 0.00 | 0.00 |
July | 107.59 | 30.35 | 75.18 | 6.93 | 68.25 | 0.00 | 0.00 |
August | 129.46 | 41.38 | 95.84 | 25.33 | 70.50 | 0.00 | 0.00 |
September | 209.83 | 72.79 | 149.61 | 77.70 | 71.91 | 0.00 | 0.00 |
October | 285.79 | 99.25 | 203.36 | 137.49 | 65.87 | 0.00 | 0.00 |
November | 326.54 | 147.49 | 244.79 | 186.64 | 58.15 | 0.00 | 0.00 |
December | 309.03 | 181.06 | 242.59 | 182.11 | 60.47 | 0.00 | 0.00 |
Annual Sum or Average | 209.67 | 99.50 | 160.21 | 92.57 | 67.63 | 0.00 | 0.00 |
Minimum of Months | 103.19 | 30.35 | 73.74 | 4.63 | 57.40 | 0.00 | 0.00 |
Maximum of Months | 326.54 | 181.06 | 244.79 | 186.64 | 75.87 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.366538E+10 | 0.319014E+10 | 0.345400E+10 | 0.241148E+10 | 0.104252E+10 | 0.00 | 0.00 |
February | 0.462034E+10 | 0.268704E+10 | 0.411975E+10 | 0.293789E+10 | 0.118186E+10 | 0.00 | 0.00 |
March | 0.733112E+10 | 0.262963E+10 | 0.617696E+10 | 0.434133E+10 | 0.183563E+10 | 0.00 | 0.00 |
April | 0.957564E+10 | 0.179115E+10 | 0.754066E+10 | 0.559723E+10 | 0.194344E+10 | 0.00 | 0.00 |
May | 0.113415E+11 | 0.138945E+10 | 0.855456E+10 | 0.635280E+10 | 0.220176E+10 | 0.00 | 0.00 |
June | 0.120609E+11 | 0.887167E+09 | 0.874855E+10 | 0.678093E+10 | 0.196762E+10 | 0.00 | 0.00 |
July | 0.109150E+11 | 0.703538E+09 | 0.783007E+10 | 0.564344E+10 | 0.218663E+10 | 0.00 | 0.00 |
August | 0.100152E+11 | 0.889492E+09 | 0.728460E+10 | 0.524237E+10 | 0.204223E+10 | 0.00 | 0.00 |
September | 0.878282E+10 | 0.132324E+10 | 0.650233E+10 | 0.486598E+10 | 0.163635E+10 | 0.00 | 0.00 |
October | 0.637450E+10 | 0.193191E+10 | 0.506369E+10 | 0.367955E+10 | 0.138414E+10 | 0.00 | 0.00 |
November | 0.433743E+10 | 0.284101E+10 | 0.388184E+10 | 0.289472E+10 | 0.987121E+09 | 0.00 | 0.00 |
December | 0.328295E+10 | 0.352735E+10 | 0.323657E+10 | 0.215514E+10 | 0.108143E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.923028E+11 | 0.237911E+11 | 0.723936E+11 | 0.529029E+11 | 0.194907E+11 | 0.00 | 0.00 |
Minimum of Months | 0.328295E+10 | 0.703538E+09 | 0.323657E+10 | 0.215514E+10 | 0.987121E+09 | 0.00 | 0.00 |
Maximum of Months | 0.120609E+11 | 0.352735E+10 | 0.874855E+10 | 0.678093E+10 | 0.220176E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.400555E+10 | 0.235798E+10 | 0.308312E+10 | 0.233601E+10 | 0.747113E+09 | 0.00 | 0.00 |
February | 0.329824E+10 | 0.191213E+10 | 0.258293E+10 | 0.182108E+10 | 0.761849E+09 | 0.00 | 0.00 |
March | 0.280421E+10 | 0.187164E+10 | 0.232306E+10 | 0.133924E+10 | 0.983820E+09 | 0.00 | 0.00 |
April | 0.183752E+10 | 0.114245E+10 | 0.152388E+10 | 0.568166E+09 | 0.955718E+09 | 0.00 | 0.00 |
May | 0.154590E+10 | 0.732470E+09 | 0.111259E+10 | 0.155108E+09 | 0.957486E+09 | 0.00 | 0.00 |
June | 0.173400E+10 | 0.401082E+09 | 0.928918E+09 | 58371560.74 | 0.870547E+09 | 0.00 | 0.00 |
July | 0.179578E+10 | 0.353916E+09 | 0.978548E+09 | 90181383.78 | 0.888366E+09 | 0.00 | 0.00 |
August | 0.202021E+10 | 0.489843E+09 | 0.124750E+10 | 0.329757E+09 | 0.917739E+09 | 0.00 | 0.00 |
September | 0.290384E+10 | 0.863409E+09 | 0.188467E+10 | 0.978830E+09 | 0.905839E+09 | 0.00 | 0.00 |
October | 0.380930E+10 | 0.134374E+10 | 0.264708E+10 | 0.178962E+10 | 0.857453E+09 | 0.00 | 0.00 |
November | 0.411453E+10 | 0.201380E+10 | 0.308356E+10 | 0.235105E+10 | 0.732514E+09 | 0.00 | 0.00 |
December | 0.402497E+10 | 0.254104E+10 | 0.315772E+10 | 0.237054E+10 | 0.787183E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.338940E+11 | 0.160235E+11 | 0.245536E+11 | 0.141880E+11 | 0.103656E+11 | 0.00 | 0.00 |
Minimum of Months | 0.154590E+10 | 0.353916E+09 | 0.928918E+09 | 58371560.74 | 0.732514E+09 | 0.00 | 0.00 |
Maximum of Months | 0.411453E+10 | 0.254104E+10 | 0.315772E+10 | 0.237054E+10 | 0.983820E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.402962E+10 | 0.226323E+10 | 0.308312E+10 | 0.233601E+10 | 0.747113E+09 | 0.00 | 0.00 |
February | 0.331588E+10 | 0.183963E+10 | 0.258293E+10 | 0.182108E+10 | 0.761849E+09 | 0.00 | 0.00 |
March | 0.282297E+10 | 0.180110E+10 | 0.232306E+10 | 0.133924E+10 | 0.983820E+09 | 0.00 | 0.00 |
April | 0.183921E+10 | 0.109111E+10 | 0.152388E+10 | 0.568166E+09 | 0.955718E+09 | 0.00 | 0.00 |
May | 0.154112E+10 | 0.690021E+09 | 0.111259E+10 | 0.155108E+09 | 0.957486E+09 | 0.00 | 0.00 |
June | 0.172903E+10 | 0.367444E+09 | 0.928918E+09 | 58371560.74 | 0.870547E+09 | 0.00 | 0.00 |
July | 0.179040E+10 | 0.319803E+09 | 0.978548E+09 | 90181383.78 | 0.888366E+09 | 0.00 | 0.00 |
August | 0.201184E+10 | 0.453714E+09 | 0.124750E+10 | 0.329757E+09 | 0.917739E+09 | 0.00 | 0.00 |
September | 0.289417E+10 | 0.825728E+09 | 0.188467E+10 | 0.978830E+09 | 0.905839E+09 | 0.00 | 0.00 |
October | 0.380558E+10 | 0.129865E+10 | 0.264708E+10 | 0.178962E+10 | 0.857453E+09 | 0.00 | 0.00 |
November | 0.412738E+10 | 0.195071E+10 | 0.308356E+10 | 0.235105E+10 | 0.732514E+09 | 0.00 | 0.00 |
December | 0.405140E+10 | 0.244973E+10 | 0.315772E+10 | 0.237054E+10 | 0.787183E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.339586E+11 | 0.153509E+11 | 0.245536E+11 | 0.141880E+11 | 0.103656E+11 | 0.00 | 0.00 |
Minimum of Months | 0.154112E+10 | 0.319803E+09 | 0.928918E+09 | 58371560.74 | 0.732514E+09 | 0.00 | 0.00 |
Maximum of Months | 0.412738E+10 | 0.244973E+10 | 0.315772E+10 | 0.237054E+10 | 0.983820E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.823410E+09 | 0.447948E+09 | 0.634397E+09 | 0.480668E+09 | 0.153729E+09 | 0.00 | 0.00 |
February | 0.678397E+09 | 0.362332E+09 | 0.531474E+09 | 0.374713E+09 | 0.156762E+09 | 0.00 | 0.00 |
March | 0.579469E+09 | 0.353569E+09 | 0.478004E+09 | 0.275569E+09 | 0.202435E+09 | 0.00 | 0.00 |
April | 0.364458E+09 | 0.220563E+09 | 0.313561E+09 | 0.116908E+09 | 0.196653E+09 | 0.00 | 0.00 |
May | 0.276376E+09 | 0.149115E+09 | 0.228933E+09 | 31915771.26 | 0.197017E+09 | 0.00 | 0.00 |
June | 0.271610E+09 | 90564598.98 | 0.191138E+09 | 12010798.58 | 0.179128E+09 | 0.00 | 0.00 |
July | 0.288160E+09 | 81300697.19 | 0.201350E+09 | 18556132.86 | 0.182794E+09 | 0.00 | 0.00 |
August | 0.346742E+09 | 0.110828E+09 | 0.256691E+09 | 67852387.83 | 0.188838E+09 | 0.00 | 0.00 |
September | 0.543892E+09 | 0.188661E+09 | 0.387798E+09 | 0.201408E+09 | 0.186390E+09 | 0.00 | 0.00 |
October | 0.765473E+09 | 0.265820E+09 | 0.544675E+09 | 0.368241E+09 | 0.176434E+09 | 0.00 | 0.00 |
November | 0.846393E+09 | 0.382289E+09 | 0.634488E+09 | 0.483763E+09 | 0.150725E+09 | 0.00 | 0.00 |
December | 0.827717E+09 | 0.484953E+09 | 0.649747E+09 | 0.487773E+09 | 0.161974E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.661210E+10 | 0.313794E+10 | 0.505226E+10 | 0.291938E+10 | 0.213288E+10 | 0.00 | 0.00 |
Minimum of Months | 0.271610E+09 | 81300697.19 | 0.191138E+09 | 12010798.58 | 0.150725E+09 | 0.00 | 0.00 |
Maximum of Months | 0.846393E+09 | 0.484953E+09 | 0.649747E+09 | 0.487773E+09 | 0.202435E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 8.14 | 3.32 | -3.0 | 3.49 | -5.4 | 41.12 | 223.64 | 0.00 |
February | 10.27 | 3.73 | -4.6 | 3.82 | -5.0 | 51.61 | 245.22 | 0.00 |
March | 12.55 | 4.69 | -5.5 | 4.62 | -3.1 | 72.41 | 273.25 | 0.00 |
April | 19.23 | 8.47 | -2.7 | 4.72 | 3.37 | 79.21 | 314.56 | 0.00 |
May | 23.84 | 12.20 | 2.64 | 5.25 | 8.38 | 86.83 | 326.20 | 0.00 |
June | 27.86 | 15.01 | 5.88 | 4.15 | 14.09 | 80.19 | 344.14 | 0.01 |
July | 27.54 | 18.90 | 14.64 | 3.53 | 17.44 | 86.25 | 283.04 | 0.01 |
August | 26.28 | 17.10 | 12.00 | 3.28 | 15.47 | 80.55 | 269.68 | 0.02 |
September | 23.38 | 15.80 | 11.20 | 2.23 | 11.29 | 66.71 | 294.09 | 0.00 |
October | 18.30 | 12.00 | 7.27 | 3.24 | 6.21 | 54.59 | 257.93 | 0.01 |
November | 11.18 | 5.23 | -1.5 | 3.40 | -3.3 | 40.23 | 258.80 | 0.00 |
December | 6.79 | 1.89 | -4.8 | 2.82 | -8.9 | 42.65 | 217.21 | 0.00 |
Annual Sum or Average | 17.98 | 9.90 | 2.67 | 3.71 | 4.26 | 65.29 | 275.60 | 0.00 |
Minimum of Months | 6.79 | 1.89 | -5.5 | 2.23 | -8.9 | 40.23 | 217.21 | 0.00 |
Maximum of Months | 27.86 | 18.90 | 14.64 | 5.25 | 17.44 | 86.83 | 344.14 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 20.60 | 03-JAN-14:00 | 8.36 | -5.0 | 9.80 | 2.22 | 118.50 | 530.50 |
February | 23.30 | 20-FEB-14:00 | 8.84 | -7.8 | 4.10 | 4.10 | 55.00 | 955.00 |
March | 25.00 | 21-MAR-15:00 | 9.49 | -8.3 | 6.20 | 5.54 | 50.00 | 873.00 |
April | 32.20 | 21-APR-13:00 | 15.18 | 2.80 | 13.90 | 18.28 | 265.50 | 638.50 |
May | 35.00 | 19-MAY-13:00 | 17.19 | 6.10 | 10.30 | 21.78 | 145.00 | 874.50 |
June | 38.90 | 02-JUN-15:00 | 16.18 | -1.1 | 4.60 | 20.40 | 234.50 | 284.00 |
July | 38.30 | 01-JUL-16:00 | 19.16 | 8.90 | 3.60 | 26.81 | 165.50 | 256.50 |
August | 37.20 | 07-AUG-15:00 | 17.85 | 6.70 | 5.70 | 24.66 | 143.50 | 615.00 |
September | 33.90 | 19-SEP-13:00 | 16.82 | 6.70 | 3.10 | 17.75 | 113.00 | 912.00 |
October | 32.80 | 01-OCT-14:00 | 15.87 | 4.40 | 5.70 | 16.12 | 127.50 | 736.50 |
November | 23.90 | 03-NOV-15:00 | 13.43 | 6.10 | 5.70 | 12.22 | 48.50 | 648.50 |
December | 18.30 | 10-DEC-14:00 | 7.94 | -2.8 | 7.20 | 4.10 | 123.00 | 52.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 18.30 | 7.94 | -8.3 | 3.10 | 2.22 | 48.50 | 52.50 | |
Maximum of Months | 38.90 | 19.16 | 8.90 | 13.90 | 26.81 | 265.50 | 955.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -4.4 | 27-JAN-06:00 | -7.3 | -15.0 | 3.60 | -23.6 | 0.00 | 0.00 |
February | -5.6 | 03-FEB-06:00 | -7.4 | -11.7 | 1.50 | -23.9 | 0.00 | 0.00 |
March | -3.9 | 02-MAR-04:00 | -6.3 | -12.8 | 1.50 | -21.3 | 0.00 | 0.00 |
April | 3.30 | 12-APR-05:00 | -1.5 | -9.4 | 2.10 | -14.9 | 37.00 | 217.50 |
May | 9.40 | 02-MAY-05:00 | 3.97 | -2.2 | 3.60 | -7.6 | 51.00 | 277.50 |
June | 15.00 | 13-JUN-04:00 | 4.40 | -10.6 | 2.10 | -4.3 | 0.00 | 0.00 |
July | 17.80 | 05-JUL-05:00 | 15.97 | 15.00 | 4.10 | 4.31 | 39.00 | 249.00 |
August | 16.70 | 31-AUG-05:00 | 13.88 | 12.20 | 4.10 | 2.64 | 36.00 | 126.50 |
September | 8.30 | 30-SEP-05:00 | 5.77 | 3.30 | 1.50 | -7.3 | 0.00 | 0.00 |
October | 6.70 | 11-OCT-05:00 | 5.82 | 5.00 | 1.50 | -5.5 | 0.00 | 0.00 |
November | -0.6 | 17-NOV-03:00 | -2.9 | -6.7 | 1.50 | -18.1 | 0.00 | 0.00 |
December | -4.4 | 27-DEC-06:00 | -5.0 | -6.1 | 2.10 | -18.6 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -5.6 | -7.4 | -15.0 | 1.50 | -23.9 | 0.00 | 0.00 | |
Maximum of Months | 17.80 | 15.97 | 15.00 | 4.10 | 4.31 | 51.00 | 277.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 10.15 | 12-JAN-15:00 | 18.90 | 2.80 | 3.60 | 6.15 | 70.50 | 491.50 |
February | 11.42 | 13-FEB-16:00 | 12.80 | 10.60 | 4.10 | 6.55 | 34.00 | 18.50 |
March | 10.74 | 10-MAR-18:00 | 13.30 | 8.90 | 1.50 | 8.54 | 0.00 | 0.00 |
April | 15.71 | 29-APR-13:00 | 30.00 | 6.70 | 4.10 | 18.28 | 336.50 | 432.50 |
May | 19.10 | 24-MAY-12:00 | 27.80 | 15.00 | 5.20 | 17.57 | 188.50 | 862.00 |
June | 20.18 | 03-JUN-14:00 | 33.90 | 13.90 | 8.80 | 23.66 | 264.50 | 316.00 |
July | 22.87 | 20-JUL-15:39 | 25.53 | 21.87 | 2.93 | 18.99 | 184.00 | 15.83 |
August | 21.16 | 02-AUG-11:00 | 30.60 | 17.20 | 3.60 | 20.75 | 154.50 | 850.00 |
September | 20.64 | 14-SEP-09:00 | 25.00 | 18.90 | 2.10 | 14.47 | 126.50 | 835.50 |
October | 19.62 | 03-OCT-13:00 | 32.80 | 13.30 | 2.60 | 21.44 | 224.50 | 577.50 |
November | 13.55 | 03-NOV-13:20 | 22.07 | 7.93 | 2.10 | 9.59 | 80.17 | 943.83 |
December | 8.27 | 10-DEC-12:00 | 17.20 | -0.6 | 5.70 | 1.58 | 198.50 | 507.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 8.27 | 12.80 | -0.6 | 1.50 | 1.58 | 0.00 | 0.00 | |
Maximum of Months | 22.87 | 33.90 | 21.87 | 8.80 | 23.66 | 336.50 | 943.83 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 9.00 | 16-JAN-01:00 | 9.00 | 9.00 | 2.10 | 4.51 | 0.00 | 0.00 |
February | 10.60 | 13-FEB-13:09 | 12.20 | 11.24 | 5.53 | 5.70 | 147.33 | 0.00 |
March | 10.00 | 11-MAR-00:00 | 10.60 | 10.24 | 2.10 | 6.15 | 0.00 | 0.00 |
April | 10.60 | 17-APR-01:00 | 17.80 | 13.38 | 7.20 | 3.48 | 0.00 | 0.00 |
May | 15.00 | 24-MAY-10:00 | 25.60 | 18.39 | 7.20 | 15.39 | 171.00 | 872.50 |
June | 17.20 | 19-JUN-17:00 | 23.90 | 19.20 | 3.60 | 15.39 | 86.00 | 324.00 |
July | 22.20 | 20-JUL-14:00 | 24.40 | 22.82 | 4.60 | 17.93 | 283.00 | 59.50 |
August | 18.90 | 01-AUG-20:00 | 22.20 | 19.91 | 4.60 | 17.75 | 0.00 | 0.00 |
September | 19.40 | 22-SEP-01:00 | 20.60 | 19.76 | 1.50 | 16.30 | 0.00 | 0.00 |
October | 17.20 | 03-OCT-19:00 | 23.30 | 19.10 | 4.60 | 18.46 | 0.00 | 0.00 |
November | 10.00 | 01-NOV-09:00 | 13.30 | 11.27 | 3.10 | 8.94 | 123.50 | 0.00 |
December | 6.10 | 13-DEC-00:00 | 8.30 | 7.10 | 7.70 | 3.06 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.10 | 8.30 | 7.10 | 1.50 | 3.06 | 0.00 | 0.00 | |
Maximum of Months | 22.20 | 25.60 | 22.82 | 7.70 | 18.46 | 283.00 | 872.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 15.16 | 28.38 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 15.21 | 35.58 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 16.80 | 47.71 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 19.62 | 58.45 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 22.88 | 63.58 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 25.71 | 66.73 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 27.35 | 58.19 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 27.33 | 54.44 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 25.68 | 50.89 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 22.83 | 39.37 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 19.57 | 32.11 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 16.77 | 26.90 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 21.28 | 46.90 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 15.16 | 26.90 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 27.35 | 66.73 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.248978E+10 | -.207673E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -413046826.8 | 58.99 | 0.00 | 0.00 |
February | 0.225772E+10 | -.188936E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -368357500.3 | 58.99 | 0.00 | 0.00 |
March | 0.246653E+10 | -.206524E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -401290814.7 | 58.99 | 0.00 | 0.00 |
April | 0.220886E+10 | -.183296E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -375897815.7 | 58.99 | 0.00 | 0.00 |
May | 0.212229E+10 | -.174090E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -381393676.9 | 58.99 | 0.00 | 0.00 |
June | 0.193749E+10 | -.157322E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -364269523.5 | 58.99 | 0.00 | 0.00 |
July | 0.187611E+10 | -.150064E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -375473546.9 | 58.99 | 0.00 | 0.00 |
August | 0.192655E+10 | -.154987E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -376673531.4 | 58.99 | 0.00 | 0.00 |
September | 0.191857E+10 | -.155186E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -366704221.0 | 58.99 | 0.00 | 0.00 |
October | 0.209931E+10 | -.171426E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -385054853.0 | 58.99 | 0.00 | 0.00 |
November | 0.218571E+10 | -.179944E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -386269479.1 | 58.99 | 0.00 | 0.00 |
December | 0.241596E+10 | -.200204E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -413920894.5 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.259049E+11 | -.212965E+11 | 8760.00 | -.460835E+10 | 58.99 | |||||
Minimum of Months | 0.187611E+10 | -.207673E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -413920894.5 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.248978E+10 | -.150064E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -364269523.5 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.83 | 0.86 | 0.50 | 25-JAN-11:30 | 254.08 | 6.43 | 0.00 | 11.67 | 212.16 | 5.01 | 0.00 | 1.17 |
February | 268.33 | 0.82 | 0.50 | 08-FEB-10:30 | 303.32 | 7.18 | 0.00 | 26.50 | 255.51 | 5.73 | 0.00 | 11.17 |
March | 351.83 | 0.78 | 0.50 | 02-MAR-10:50 | 378.47 | 8.26 | 0.00 | 84.33 | 318.26 | 6.70 | 0.00 | 55.00 |
April | 373.83 | 0.76 | 0.50 | 01-APR-10:20 | 393.84 | 9.56 | 0.00 | 83.17 | 334.38 | 7.96 | 0.00 | 57.83 |
May | 408.83 | 0.76 | 0.50 | 01-MAY-10:30 | 386.77 | 10.70 | 0.00 | 71.50 | 327.32 | 8.98 | 0.00 | 42.00 |
June | 398.00 | 0.77 | 0.50 | 02-JUN-10:30 | 367.30 | 11.04 | 0.00 | 45.17 | 310.93 | 9.19 | 0.00 | 21.00 |
July | 400.17 | 0.76 | 0.50 | 01-JUL-11:50 | 384.15 | 10.99 | 0.00 | 80.67 | 324.50 | 9.19 | 0.00 | 50.83 |
August | 377.83 | 0.75 | 0.50 | 01-AUG-10:50 | 632.73 | 10.23 | 0.00 | 91.67 | 824.11 | 8.59 | 0.00 | 63.83 |
September | 365.83 | 0.75 | 0.50 | 02-SEP-09:39 | 2592.17 | 8.27 | 0.00 | 111.33 | 4834.04 | 6.67 | 0.00 | 118.33 |
October | 318.83 | 0.81 | 0.50 | 02-OCT-09:20 | 320.97 | 7.54 | 0.00 | 41.17 | 269.89 | 6.07 | 0.00 | 24.17 |
November | 295.83 | 0.88 | 0.50 | 02-NOV-10:20 | 239.90 | 6.12 | 0.00 | 5.17 | 202.41 | 4.74 | 0.00 | 1.33 |
December | 289.50 | 0.85 | 0.58 | 01-DEC-11:30 | 253.98 | 6.68 | 0.00 | 4.50 | 505.29 | 5.29 | 0.00 | 9.17 |
Annual Sum or Average | 4125.67 | 0.79 | 563.39 | 8.82 | 0.00 | 656.83 | 757.15 | 7.23 | 0.00 | 455.83 | ||
Minimum of Months | 268.33 | 0.75 | 0.50 | 239.90 | 6.12 | 0.00 | 4.50 | 202.41 | 4.74 | 0.00 | 1.17 | |
Maximum of Months | 408.83 | 0.88 | 0.58 | 2592.17 | 11.04 | 0.00 | 111.33 | 4834.04 | 9.19 | 0.00 | 118.33 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.977616E+09 | 51528.21 | 09-JAN-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.546830E+09 | 51528.21 | 02-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.196931E+09 | 44474.63 | 02-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.112580E+09 | 51528.21 | 28-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.134050E+10 | 51528.21 | 05-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.317445E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.134050E+10 | 51528.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.135243E+10 | 57480.40 | 27-JAN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.640096E+09 | 49365.71 | 03-FEB-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.174419E+09 | 25741.03 | 02-MAR-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.177073E+09 | 29490.11 | 28-NOV-07:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.284997E+10 | 59237.71 | 29-DEC-08:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.519399E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.284997E+10 | 59237.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.103006E+09 | 6118.52 | 28-JAN-07:57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 77376329.85 | 5335.94 | 03-FEB-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 36069753.12 | 3747.27 | 02-MAR-07:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 22388396.89 | 12124.75 | 28-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.172180E+09 | 31224.97 | 27-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.411021E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.172180E+09 | 31224.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.425457E+09 | 24851.43 | 28-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.289485E+09 | 17290.99 | 02-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.208729E+09 | 15078.58 | 02-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 12879585.54 | 2849.70 | 11-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.112908E+09 | 25506.08 | 28-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.596707E+09 | 25506.08 | 26-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.164617E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.596707E+09 | 25506.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.397302E+10 | 15409.22 | 26-JAN-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.216244E+10 | 12289.01 | 02-FEB-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.123538E+10 | 13524.63 | 01-MAR-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.217470E+09 | 6759.70 | 11-APR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 62523.08 | 104.21 | 23-SEP-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.201170E+09 | 5269.73 | 24-OCT-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.189700E+10 | 13767.76 | 26-NOV-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.464763E+10 | 19267.28 | 26-DEC-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.143342E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.464763E+10 | 19267.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 16756.72 | 16754.37 | 1.39 | 03-JAN-15:00 | 1.39 | 0.00 |
February | 0.00 | 0.00 | 0.146256E+09 | 0.146256E+09 | 4153.29 | 22-FEB-16:00 | 4153.29 | 0.00 |
March | 0.00 | 0.00 | 0.770630E+09 | 0.770628E+09 | 7206.19 | 22-MAR-14:10 | 7206.19 | 0.00 |
April | 0.00 | 0.00 | 0.702471E+10 | 0.698263E+10 | 35610.25 | 30-APR-08:62 | 31555.42 | 0.00 |
May | 0.00 | 0.00 | 0.154329E+11 | 0.148677E+11 | 38304.54 | 28-MAY-08:62 | 28169.23 | 0.00 |
June | 0.00 | 0.00 | 0.220894E+11 | 0.209741E+11 | 38125.47 | 04-JUN-08:62 | 30820.48 | 0.00 |
July | 0.00 | 0.00 | 0.267264E+11 | 0.219265E+11 | 41170.34 | 22-JUL-06:02 | 17976.54 | 0.00 |
August | 0.00 | 0.00 | 0.232306E+11 | 0.200608E+11 | 40483.92 | 03-AUG-06:02 | 20983.47 | 0.00 |
September | 0.00 | 0.00 | 0.189268E+11 | 0.162328E+11 | 39878.81 | 22-SEP-06:02 | 19901.00 | 0.00 |
October | 0.00 | 0.00 | 0.765451E+10 | 0.683929E+10 | 38397.03 | 04-OCT-06:02 | 21801.94 | 0.00 |
November | 0.00 | 0.00 | 0.451468E+09 | 0.447929E+09 | 8497.08 | 03-NOV-16:00 | 8497.08 | 0.00 |
December | 0.00 | 0.00 | 16181.01 | 16181.01 | 0.71 | 09-DEC-13:00 | 0.71 | 0.00 |
Annual Sum or Average | 0.122454E+12 | 0.109249E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 16181.01 | 16181.01 | 0.71 | 0.71 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.267264E+11 | 0.219265E+11 | 41170.34 | 31555.42 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.229002E+09 | 0.228041E+09 | 14529.07 | 03-JAN-15:10 | 14529.07 | 0.00 |
February | 0.00 | 0.00 | 0.348167E+10 | 0.348020E+10 | 66123.36 | 08-FEB-07:03 | 57622.70 | 0.00 |
March | 0.00 | 0.00 | 0.107923E+11 | 0.107878E+11 | 159069.92 | 10-MAR-07:02 | 159069.92 | 0.00 |
April | 0.00 | 0.00 | 0.473369E+11 | 0.468378E+11 | 168811.81 | 30-APR-08:62 | 142694.84 | 0.00 |
May | 0.00 | 0.00 | 0.850307E+11 | 0.815393E+11 | 181321.84 | 28-MAY-08:62 | 127829.17 | 0.00 |
June | 0.00 | 0.00 | 0.112343E+12 | 0.105777E+12 | 180585.02 | 04-JUN-08:62 | 138160.34 | 0.00 |
July | 0.00 | 0.00 | 0.132966E+12 | 0.106204E+12 | 194602.94 | 22-JUL-06:02 | 86631.32 | 0.00 |
August | 0.00 | 0.00 | 0.115600E+12 | 0.977531E+11 | 191600.50 | 03-AUG-06:02 | 98246.27 | 0.00 |
September | 0.00 | 0.00 | 0.957937E+11 | 0.806836E+11 | 188329.38 | 22-SEP-06:02 | 95360.79 | 0.00 |
October | 0.00 | 0.00 | 0.464187E+11 | 0.407430E+11 | 181408.44 | 04-OCT-06:02 | 103335.84 | 0.00 |
November | 0.00 | 0.00 | 0.634362E+10 | 0.612906E+10 | 165838.69 | 01-NOV-06:02 | 124687.90 | 0.00 |
December | 0.00 | 0.00 | 1561736.50 | 1560846.29 | 375.00 | 19-DEC-16:00 | 375.00 | 0.00 |
Annual Sum or Average | 0.656337E+12 | 0.580165E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 1561736.50 | 1560846.29 | 375.00 | 375.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.132966E+12 | 0.106204E+12 | 194602.94 | 159069.92 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.171012E+09 | 0.170420E+09 | 4962.95 | 03-JAN-14:40 | 4962.95 | 0.00 |
February | 0.00 | 0.00 | 0.974845E+09 | 0.974843E+09 | 7375.55 | 21-FEB-15:10 | 7375.55 | 0.00 |
March | 0.00 | 0.00 | 0.184071E+10 | 0.184071E+10 | 8737.44 | 22-MAR-13:10 | 8737.44 | 0.00 |
April | 0.00 | 0.00 | 0.639161E+10 | 0.634488E+10 | 23210.77 | 30-APR-08:62 | 19759.08 | 0.00 |
May | 0.00 | 0.00 | 0.109799E+11 | 0.105942E+11 | 24952.10 | 28-MAY-08:62 | 17578.88 | 0.00 |
June | 0.00 | 0.00 | 0.146056E+11 | 0.138689E+11 | 24830.95 | 04-JUN-08:62 | 19159.60 | 0.00 |
July | 0.00 | 0.00 | 0.176013E+11 | 0.144596E+11 | 26838.96 | 22-JUL-06:02 | 11385.18 | 0.00 |
August | 0.00 | 0.00 | 0.161575E+11 | 0.139935E+11 | 26403.51 | 03-AUG-06:02 | 13154.47 | 0.00 |
September | 0.00 | 0.00 | 0.147548E+11 | 0.128314E+11 | 26027.80 | 22-SEP-06:02 | 12472.49 | 0.00 |
October | 0.00 | 0.00 | 0.858010E+10 | 0.773966E+10 | 24976.64 | 04-OCT-06:02 | 13914.99 | 0.00 |
November | 0.00 | 0.00 | 0.198745E+10 | 0.193939E+10 | 22342.54 | 10-NOV-07:02 | 19979.51 | 0.00 |
December | 0.00 | 0.00 | 39305813.80 | 39305664.17 | 2138.77 | 23-DEC-15:00 | 2138.77 | 0.00 |
Annual Sum or Average | 0.940842E+11 | 0.847968E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 39305813.80 | 39305664.17 | 2138.77 | 2138.77 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.176013E+11 | 0.144596E+11 | 26838.96 | 19979.51 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 75920440.09 | 75453911.27 | 3099.92 | 03-JAN-14:30 | 3099.92 | 0.00 |
February | 0.00 | 0.00 | 0.542033E+09 | 0.542032E+09 | 5115.60 | 21-FEB-15:10 | 5115.60 | 0.00 |
March | 0.00 | 0.00 | 0.967043E+09 | 0.967042E+09 | 6070.82 | 22-MAR-13:10 | 6070.82 | 0.00 |
April | 0.00 | 0.00 | 0.429333E+10 | 0.425693E+10 | 18803.07 | 30-APR-08:62 | 15801.65 | 0.00 |
May | 0.00 | 0.00 | 0.797962E+10 | 0.765888E+10 | 20230.47 | 28-MAY-08:62 | 14102.48 | 0.00 |
June | 0.00 | 0.00 | 0.113050E+11 | 0.106861E+11 | 20136.67 | 04-JUN-08:62 | 15334.76 | 0.00 |
July | 0.00 | 0.00 | 0.138553E+11 | 0.111628E+11 | 21738.53 | 22-JUL-06:02 | 9266.73 | 0.00 |
August | 0.00 | 0.00 | 0.125763E+11 | 0.107614E+11 | 21396.67 | 03-AUG-06:02 | 10631.05 | 0.00 |
September | 0.00 | 0.00 | 0.115169E+11 | 0.986614E+10 | 21080.01 | 22-SEP-06:02 | 10136.47 | 0.00 |
October | 0.00 | 0.00 | 0.633096E+10 | 0.566984E+10 | 20270.96 | 04-OCT-06:02 | 11153.96 | 0.00 |
November | 0.00 | 0.00 | 0.129643E+10 | 0.126163E+10 | 18237.83 | 11-NOV-09:02 | 16063.23 | 0.00 |
December | 0.00 | 0.00 | 3880060.16 | 3879974.62 | 695.80 | 23-DEC-15:00 | 695.80 | 0.00 |
Annual Sum or Average | 0.707426E+11 | 0.629122E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 3880060.16 | 3879974.62 | 695.80 | 695.80 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.138553E+11 | 0.111628E+11 | 21738.53 | 16063.23 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.242783E+10 | 0.49 | 1862.10 | 01-JAN-08:65 | 1.01 |
February | 0.176789E+10 | 0.40 | 1862.10 | 01-FEB-06:03 | 1.01 |
March | 0.160428E+10 | 0.33 | 1862.10 | 01-MAR-06:03 | 1.01 |
April | 0.507644E+09 | 0.11 | 1862.10 | 01-APR-07:10 | 1.02 |
May | 37229946.50 | 0.01 | 1862.10 | 01-MAY-07:06 | 1.01 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 12550526.07 | 0.00 | 1862.10 | 23-SEP-15:56 | 0.99 |
October | 0.450453E+09 | 0.09 | 1862.10 | 06-OCT-07:07 | 1.00 |
November | 0.167077E+10 | 0.35 | 1862.10 | 01-NOV-07:10 | 1.01 |
December | 0.248620E+10 | 0.51 | 1862.10 | 01-DEC-06:03 | 1.01 |
Annual Sum or Average | 0.109649E+11 | 0.19 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.248620E+10 | 0.51 | 1862.10 | 1.02 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.386777E+10 | 0.60 | 2414.34 | 01-JAN-10:00 | 1.01 |
February | 0.351142E+10 | 0.61 | 2414.34 | 02-FEB-07:08 | 1.02 |
March | 0.393731E+10 | 0.62 | 2414.34 | 01-MAR-07:17 | 1.01 |
April | 0.378086E+10 | 0.61 | 2414.34 | 01-APR-12:20 | 1.01 |
May | 0.390254E+10 | 0.61 | 2414.34 | 01-MAY-07:40 | 1.01 |
June | 0.380693E+10 | 0.61 | 2414.34 | 05-JUN-07:40 | 1.00 |
July | 0.387647E+10 | 0.60 | 2414.34 | 01-JUL-08:00 | 1.00 |
August | 0.393731E+10 | 0.61 | 2414.34 | 04-AUG-19:30 | 1.00 |
September | 0.378086E+10 | 0.61 | 2414.34 | 02-SEP-07:40 | 1.00 |
October | 0.386777E+10 | 0.60 | 2414.34 | 01-OCT-09:20 | 1.01 |
November | 0.372871E+10 | 0.60 | 2414.34 | 03-NOV-12:00 | 1.00 |
December | 0.387647E+10 | 0.61 | 2414.34 | 02-DEC-07:17 | 1.01 |
Annual Sum or Average | 0.458744E+11 | 0.61 | |||
Minimum of Months | 0.351142E+10 | 0.60 | 2414.34 | 1.00 | |
Maximum of Months | 0.393731E+10 | 0.62 | 2414.34 | 1.02 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.257257E+11 | 1.03 | 16058.49 | 05-JAN-16:50 | 1.73 |
February | 0.233555E+11 | 1.04 | 16058.49 | 02-FEB-07:23 | 1.73 |
March | 0.261882E+11 | 1.05 | 16058.49 | 24-MAR-14:50 | 1.73 |
April | 0.251476E+11 | 1.04 | 16058.49 | 01-APR-08:35 | 1.73 |
May | 0.259569E+11 | 1.04 | 16058.49 | 01-MAY-05:40 | 1.73 |
June | 0.253210E+11 | 1.04 | 16058.49 | 01-JUN-08:50 | 1.73 |
July | 0.257835E+11 | 1.02 | 16058.49 | 03-JUL-05:50 | 1.71 |
August | 0.261882E+11 | 1.04 | 16058.49 | 19-AUG-06:50 | 1.70 |
September | 0.251476E+11 | 1.03 | 16058.49 | 03-SEP-08:20 | 1.70 |
October | 0.257257E+11 | 1.03 | 16058.49 | 23-OCT-17:05 | 1.72 |
November | 0.248007E+11 | 1.03 | 16058.49 | 09-NOV-08:09 | 1.73 |
December | 0.257835E+11 | 1.04 | 16058.49 | 01-DEC-11:00 | 1.73 |
Annual Sum or Average | 0.305124E+12 | 1.04 | |||
Minimum of Months | 0.233555E+11 | 1.02 | 16058.49 | 1.70 | |
Maximum of Months | 0.261882E+11 | 1.05 | 16058.49 | 1.73 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.233845E+10 | 0.63 | 1459.71 | 01-JAN-18:30 | 1.04 |
February | 0.212300E+10 | 0.63 | 1459.71 | 01-FEB-07:30 | 1.05 |
March | 0.238049E+10 | 0.64 | 1459.71 | 01-MAR-07:07 | 1.05 |
April | 0.228590E+10 | 0.63 | 1459.71 | 01-APR-08:25 | 1.05 |
May | 0.235947E+10 | 0.63 | 1459.71 | 01-MAY-08:00 | 1.05 |
June | 0.230166E+10 | 0.63 | 1459.71 | 01-JUN-07:40 | 1.05 |
July | 0.234370E+10 | 0.62 | 1459.71 | 01-JUL-05:20 | 1.04 |
August | 0.238049E+10 | 0.63 | 1459.71 | 01-AUG-06:06 | 1.03 |
September | 0.228590E+10 | 0.63 | 1459.71 | 01-SEP-06:08 | 1.03 |
October | 0.233845E+10 | 0.62 | 1459.71 | 01-OCT-10:25 | 1.04 |
November | 0.225437E+10 | 0.62 | 1459.71 | 01-NOV-16:20 | 1.04 |
December | 0.234370E+10 | 0.63 | 1459.71 | 01-DEC-19:20 | 1.05 |
Annual Sum or Average | 0.277356E+11 | 0.63 | |||
Minimum of Months | 0.212300E+10 | 0.62 | 1459.71 | 1.03 | |
Maximum of Months | 0.238049E+10 | 0.64 | 1459.71 | 1.05 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.183630E+10 | 0.63 | 1146.25 | 01-JAN-11:55 | 1.04 |
February | 0.166711E+10 | 0.63 | 1146.25 | 01-FEB-07:50 | 1.05 |
March | 0.186931E+10 | 0.64 | 1146.25 | 01-MAR-07:10 | 1.05 |
April | 0.179503E+10 | 0.63 | 1146.25 | 01-APR-08:53 | 1.05 |
May | 0.185280E+10 | 0.63 | 1146.25 | 01-MAY-06:30 | 1.05 |
June | 0.180741E+10 | 0.63 | 1146.25 | 01-JUN-06:50 | 1.05 |
July | 0.184043E+10 | 0.62 | 1146.25 | 01-JUL-05:07 | 1.04 |
August | 0.186931E+10 | 0.63 | 1146.25 | 01-AUG-05:40 | 1.03 |
September | 0.179503E+10 | 0.63 | 1146.25 | 01-SEP-06:30 | 1.03 |
October | 0.183630E+10 | 0.62 | 1146.25 | 21-OCT-07:33 | 1.04 |
November | 0.177027E+10 | 0.62 | 1146.25 | 01-NOV-10:33 | 1.04 |
December | 0.184043E+10 | 0.63 | 1146.25 | 30-DEC-13:20 | 1.05 |
Annual Sum or Average | 0.217797E+11 | 0.63 | |||
Minimum of Months | 0.166711E+10 | 0.62 | 1146.25 | 1.03 | |
Maximum of Months | 0.186931E+10 | 0.64 | 1146.25 | 1.05 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.17 | 0.00 |
February | 0.08 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.04 | 0.00 |
June | 0.24 | 0.00 |
July | 0.38 | 0.00 |
August | 0.12 | 0.00 |
September | 0.04 | 0.00 |
October | 0.04 | 0.00 |
November | 0.00 | 0.00 |
December | 0.08 | 0.00 |
Annual Sum or Average | 1.19 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.38 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.50 | 25.84 |
February | 1.47 | 24.87 |
March | 1.29 | 24.18 |
April | 0.25 | 17.23 |
May | 0.29 | 0.00 |
June | 0.16 | 0.00 |
July | 0.38 | 0.00 |
August | 0.12 | 0.00 |
September | 0.21 | 20.67 |
October | 0.04 | 0.00 |
November | 1.51 | 25.84 |
December | 1.28 | 25.84 |
Annual Sum or Average | 8.50 | 22.05 |
Minimum of Months | 0.04 | 0.00 |
Maximum of Months | 1.51 | 25.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.53 | 2.05 |
February | 0.30 | 1.02 |
March | 0.71 | 2.15 |
April | 0.33 | 1.83 |
May | 0.79 | 0.51 |
June | 0.63 | 0.00 |
July | 0.38 | 0.00 |
August | 0.53 | 0.00 |
September | 0.35 | 0.00 |
October | 0.21 | 0.00 |
November | 0.53 | 1.92 |
December | 0.53 | 1.41 |
Annual Sum or Average | 5.81 | 0.98 |
Minimum of Months | 0.21 | 0.00 |
Maximum of Months | 0.79 | 2.15 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.12 | 0.81 |
February | 0.10 | 2.44 |
March | 0.51 | 2.04 |
April | 0.32 | 2.44 |
May | 0.29 | 1.39 |
June | 0.57 | 1.41 |
July | 0.38 | 0.00 |
August | 0.37 | 0.00 |
September | 0.29 | 1.39 |
October | 0.17 | 0.61 |
November | 0.67 | 2.44 |
December | 0.17 | 1.22 |
Annual Sum or Average | 3.96 | 1.45 |
Minimum of Months | 0.10 | 0.00 |
Maximum of Months | 0.67 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 18.55 | 0.00 |
February | 23.53 | 0.00 |
March | 28.98 | 0.00 |
April | 18.11 | 0.00 |
May | 4.93 | 0.00 |
June | 4.22 | 0.00 |
July | 3.75 | 0.00 |
August | 4.22 | 0.00 |
September | 3.79 | 0.00 |
October | 19.44 | 0.00 |
November | 25.96 | 0.00 |
December | 19.73 | 0.00 |
Annual Sum or Average | 175.22 | 0.00 |
Minimum of Months | 3.75 | 0.00 |
Maximum of Months | 28.98 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.386778E+10 | 0.122202E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.355267E+10 | 0.683538E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.415379E+10 | 0.246164E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.581005E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.837588E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.104361E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.114347E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.105215E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.904883E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.597243E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.385305E+10 | 0.140724E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.387647E+10 | 0.167562E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.809033E+11 | 0.396807E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.355267E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.114347E+11 | 0.167562E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.257966E+11 | 0.169054E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.244216E+11 | 0.800120E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.294719E+11 | 0.218023E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.399892E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.530494E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.626433E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.673816E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.625301E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.547085E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.397631E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.267100E+11 | 0.221341E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.257840E+11 | 0.356246E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.512249E+12 | 0.649248E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.244216E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.673816E+11 | 0.356246E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.238459E+10 | 0.128758E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.238297E+10 | 96720412.31 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.287580E+10 | 45087191.40 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.408183E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.551816E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.669142E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.733281E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.693607E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.631613E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.459902E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.277575E+10 | 27985496.12 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.235461E+10 | 0.215225E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.542492E+11 | 0.513776E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.235461E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.733281E+10 | 0.215225E+09 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.185695E+10 | 0.531822E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.181333E+10 | 0.361856E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.213344E+10 | 0.260912E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.302123E+10 | 16099481.93 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.417523E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.522777E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.577791E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.543106E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.495167E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.351373E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.211196E+10 | 0.141136E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.184151E+10 | 0.745884E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.418558E+11 | 0.205771E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.181333E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.577791E+10 | 0.745884E+09 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.386777E+10 | 16756.72 | 0.977616E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.351142E+10 | 0.146256E+09 | 0.546830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.393731E+10 | 0.770630E+09 | 0.196931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.378086E+10 | 0.702471E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.390254E+10 | 0.154329E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.380693E+10 | 0.220894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.387647E+10 | 0.267264E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.393731E+10 | 0.232306E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.378086E+10 | 0.189268E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.386777E+10 | 0.765451E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.372871E+10 | 0.451468E+09 | 0.112580E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.387647E+10 | 16181.01 | 0.134050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.458744E+11 | 0.122454E+12 | 0.317445E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.351142E+10 | 16181.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.393731E+10 | 0.267264E+11 | 0.134050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.257257E+11 | 0.229002E+09 | 0.135243E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.233555E+11 | 0.348167E+10 | 0.640096E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.261882E+11 | 0.107923E+11 | 0.174419E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.251476E+11 | 0.473369E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.259569E+11 | 0.850307E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.253210E+11 | 0.112343E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.257835E+11 | 0.132966E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.261882E+11 | 0.115600E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.251476E+11 | 0.957937E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.257257E+11 | 0.464187E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.248007E+11 | 0.634362E+10 | 0.177073E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.257835E+11 | 1561736.50 | 0.284997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.305124E+12 | 0.656337E+12 | 0.519399E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.233555E+11 | 1561736.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.261882E+11 | 0.132966E+12 | 0.284997E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.233845E+10 | 0.171012E+09 | 0.103006E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.212300E+10 | 0.974845E+09 | 77376329.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.238049E+10 | 0.184071E+10 | 36069753.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.228590E+10 | 0.639161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.235947E+10 | 0.109799E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.230166E+10 | 0.146056E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.234370E+10 | 0.176013E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.238049E+10 | 0.161575E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.228590E+10 | 0.147548E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.233845E+10 | 0.858010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.225437E+10 | 0.198745E+10 | 22388396.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.234370E+10 | 39305813.80 | 0.172180E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.277356E+11 | 0.940842E+11 | 0.411021E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.212300E+10 | 39305813.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.238049E+10 | 0.176013E+11 | 0.172180E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.183630E+10 | 75920440.09 | 0.425457E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.166711E+10 | 0.542033E+09 | 0.289485E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186931E+10 | 0.967043E+09 | 0.208729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.179503E+10 | 0.429333E+10 | 12879585.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.185280E+10 | 0.797962E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.180741E+10 | 0.113050E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.184043E+10 | 0.138553E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.186931E+10 | 0.125763E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.179503E+10 | 0.115169E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.183630E+10 | 0.633096E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.177027E+10 | 0.129643E+10 | 0.112908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.184043E+10 | 3880060.16 | 0.596707E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.217797E+11 | 0.707426E+11 | 0.164617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.166711E+10 | 3880060.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.186931E+10 | 0.138553E+11 | 0.596707E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.386777E+10 | 0.00 | 0.00 | 0.00 | 4731.40 | 0.00 | 0.122202E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.351142E+10 | 0.00 | 0.00 | 0.00 | 41256098.31 | 0.00 | 0.683538E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.393731E+10 | 0.00 | 0.00 | 0.00 | 0.216480E+09 | 0.00 | 0.246164E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.378086E+10 | 0.00 | 0.00 | 0.00 | 0.202920E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.390254E+10 | 0.00 | 0.00 | 0.00 | 0.447334E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.380693E+10 | 0.00 | 0.00 | 0.00 | 0.662914E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.387647E+10 | 0.00 | 0.00 | 0.00 | 0.755826E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.393731E+10 | 0.00 | 0.00 | 0.00 | 0.658420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.378086E+10 | 0.00 | 0.00 | 0.00 | 0.526797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.386777E+10 | 0.00 | 0.00 | 0.00 | 0.210465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.372871E+10 | 0.00 | 0.00 | 0.00 | 0.124344E+09 | 0.00 | 0.140724E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.387647E+10 | 0.00 | 0.00 | 0.00 | 4567.66 | 0.00 | 0.167562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.458744E+11 | 0.00 | 0.00 | 0.00 | 0.350289E+11 | 0.00 | 0.396807E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.351142E+10 | 0.00 | 0.00 | 0.00 | 4567.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.393731E+10 | 0.00 | 0.00 | 0.00 | 0.755826E+10 | 0.00 | 0.167562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.257257E+11 | 0.00 | 0.00 | 0.00 | 70892206.71 | 0.00 | 0.169054E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.233555E+11 | 0.00 | 0.00 | 0.00 | 0.106613E+10 | 0.00 | 0.800120E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.261882E+11 | 0.00 | 0.00 | 0.00 | 0.328370E+10 | 0.00 | 0.218023E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.251476E+11 | 0.00 | 0.00 | 0.00 | 0.148416E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.259569E+11 | 0.00 | 0.00 | 0.00 | 0.270924E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.253210E+11 | 0.00 | 0.00 | 0.00 | 0.373223E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.257835E+11 | 0.00 | 0.00 | 0.00 | 0.415981E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.261882E+11 | 0.00 | 0.00 | 0.00 | 0.363419E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.251476E+11 | 0.00 | 0.00 | 0.00 | 0.295609E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.257257E+11 | 0.00 | 0.00 | 0.00 | 0.140374E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.248007E+11 | 0.00 | 0.00 | 0.00 | 0.190924E+10 | 0.00 | 0.221341E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.257835E+11 | 0.00 | 0.00 | 0.00 | 492460.67 | 0.00 | 0.356246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.305124E+12 | 0.00 | 0.00 | 0.00 | 0.207125E+12 | 0.00 | 0.649248E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.233555E+11 | 0.00 | 0.00 | 0.00 | 492460.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.261882E+11 | 0.00 | 0.00 | 0.00 | 0.415981E+11 | 0.00 | 0.356246E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.233845E+10 | 0.00 | 0.00 | 0.00 | 46143712.56 | 0.00 | 0.128758E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.212300E+10 | 0.00 | 0.00 | 0.00 | 0.259970E+09 | 0.00 | 96720412.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.238049E+10 | 0.00 | 0.00 | 0.00 | 0.495309E+09 | 0.00 | 45087191.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.228590E+10 | 0.00 | 0.00 | 0.00 | 0.179593E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.235947E+10 | 0.00 | 0.00 | 0.00 | 0.315869E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.230166E+10 | 0.00 | 0.00 | 0.00 | 0.438975E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.234370E+10 | 0.00 | 0.00 | 0.00 | 0.498911E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.238049E+10 | 0.00 | 0.00 | 0.00 | 0.455558E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.228590E+10 | 0.00 | 0.00 | 0.00 | 0.403023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.233845E+10 | 0.00 | 0.00 | 0.00 | 0.226057E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.225437E+10 | 0.00 | 0.00 | 0.00 | 0.521382E+09 | 0.00 | 27985496.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.234370E+10 | 0.00 | 0.00 | 0.00 | 10904172.63 | 0.00 | 0.215225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.277356E+11 | 0.00 | 0.00 | 0.00 | 0.265136E+11 | 0.00 | 0.513776E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.212300E+10 | 0.00 | 0.00 | 0.00 | 10904172.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.238049E+10 | 0.00 | 0.00 | 0.00 | 0.498911E+10 | 0.00 | 0.215225E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.183630E+10 | 0.00 | 0.00 | 0.00 | 20646150.96 | 0.00 | 0.531822E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.166711E+10 | 0.00 | 0.00 | 0.00 | 0.146215E+09 | 0.00 | 0.361856E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.186931E+10 | 0.00 | 0.00 | 0.00 | 0.264128E+09 | 0.00 | 0.260912E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.179503E+10 | 0.00 | 0.00 | 0.00 | 0.122620E+10 | 0.00 | 16099481.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.185280E+10 | 0.00 | 0.00 | 0.00 | 0.232242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.180741E+10 | 0.00 | 0.00 | 0.00 | 0.342035E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.184043E+10 | 0.00 | 0.00 | 0.00 | 0.393748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.186931E+10 | 0.00 | 0.00 | 0.00 | 0.356175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.179503E+10 | 0.00 | 0.00 | 0.00 | 0.315664E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.183630E+10 | 0.00 | 0.00 | 0.00 | 0.167743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.177027E+10 | 0.00 | 0.00 | 0.00 | 0.341683E+09 | 0.00 | 0.141136E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.184043E+10 | 0.00 | 0.00 | 0.00 | 1086581.86 | 0.00 | 0.745884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.217797E+11 | 0.00 | 0.00 | 0.00 | 0.200760E+11 | 0.00 | 0.205771E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.166711E+10 | 0.00 | 0.00 | 0.00 | 1086581.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.186931E+10 | 0.00 | 0.00 | 0.00 | 0.393748E+10 | 0.00 | 0.745884E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.455323E+10 | 0.00 | 0.00 | 240643.68 | 0.00 | 0.857954E+09 | 0.683414E+09 | 0.00 | 0.22 |
February | 0.312037E+10 | 0.00 | 0.00 | 1056246.25 | 0.00 | 0.482088E+09 | 0.200620E+10 | 0.00 | 0.35 |
March | 0.211899E+10 | 0.00 | 0.00 | 3581951.27 | 0.00 | 0.188700E+09 | 0.465833E+10 | 0.00 | 0.54 |
April | 0.403412E+09 | 52004065.03 | 0.00 | 11385062.16 | 0.00 | 0.00 | 0.443199E+10 | 0.00 | 0.59 |
May | 99013921.46 | 0.610589E+09 | 0.00 | 11095628.94 | 1482087.86 | 0.00 | 0.191340E+10 | 0.00 | 0.47 |
June | 62818529.54 | 0.151544E+10 | 0.00 | 4942339.03 | 2243184.79 | 0.00 | 0.574660E+09 | 0.00 | 0.38 |
July | 14255245.76 | 0.384512E+10 | 0.00 | 2499166.52 | 14905417.80 | 0.00 | 0.139085E+09 | 0.00 | 0.37 |
August | 56893178.16 | 0.212324E+10 | 0.00 | 5664803.22 | 4392495.00 | 0.00 | 0.902824E+09 | 0.00 | 0.48 |
September | 76594658.89 | 0.143824E+10 | 0.00 | 9857955.74 | 1343151.37 | 0.00 | 0.163949E+10 | 0.00 | 0.50 |
October | 0.248242E+09 | 0.323634E+09 | 0.00 | 13737706.81 | 1339091.61 | 0.00 | 0.660039E+10 | 0.00 | 0.79 |
November | 0.202483E+10 | 0.00 | 0.00 | 5179111.00 | 0.00 | 0.105029E+09 | 0.551407E+10 | 0.00 | 0.50 |
December | 0.449825E+10 | 0.00 | 0.00 | 295959.33 | 0.00 | 0.113526E+10 | 0.868177E+09 | 0.00 | 0.22 |
Annual Sum or Average | 0.172769E+11 | 0.990825E+10 | 0.00 | 69536573.95 | 25705428.42 | 0.276903E+10 | 0.299320E+11 | 0.00 | 0.45 |
Minimum of Months | 14255245.76 | 0.00 | 0.00 | 240643.68 | 0.00 | 0.00 | 0.139085E+09 | 0.00 | 0.22 |
Maximum of Months | 0.455323E+10 | 0.384512E+10 | 0.00 | 13737706.81 | 14905417.80 | 0.113526E+10 | 0.660039E+10 | 0.00 | 0.79 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.265496E+11 | 0.00 | 0.00 | 16291904.30 | 0.00 | 0.200702E+09 | 0.253653E+11 | 0.00 | 0.49 |
February | 0.151885E+11 | 0.00 | 0.00 | 27272227.80 | 0.00 | 37295050.49 | 0.310269E+11 | 0.00 | 0.66 |
March | 0.104086E+11 | 0.00 | 0.00 | 49839289.47 | 0.00 | 0.00 | 0.404122E+11 | 0.00 | 0.84 |
April | 0.222546E+10 | 0.880412E+09 | 0.00 | 71262578.76 | 0.00 | 0.00 | 0.254527E+11 | 0.00 | 0.78 |
May | 0.126230E+10 | 0.697455E+10 | 0.00 | 42379457.95 | 2725606.85 | 0.00 | 0.957977E+10 | 0.00 | 0.65 |
June | 0.364642E+09 | 0.163146E+11 | 0.00 | 17460530.02 | 30768146.56 | 0.00 | 0.236741E+10 | 0.00 | 0.56 |
July | 14778158.79 | 0.329534E+11 | 0.00 | 5358227.60 | 0.300781E+09 | 0.00 | 0.203027E+09 | 0.00 | 0.55 |
August | 0.311815E+09 | 0.200732E+11 | 0.00 | 17575473.22 | 0.136821E+09 | 0.00 | 0.288588E+10 | 0.00 | 0.63 |
September | 0.504170E+09 | 0.136068E+11 | 0.00 | 32381241.54 | 68305264.73 | 0.00 | 0.609641E+10 | 0.00 | 0.65 |
October | 0.136437E+10 | 0.333616E+10 | 0.00 | 75717123.53 | 12435930.76 | 0.00 | 0.323268E+11 | 0.00 | 0.91 |
November | 0.122126E+11 | 0.00 | 0.00 | 48522748.61 | 0.00 | 9100348.20 | 0.401528E+11 | 0.00 | 0.76 |
December | 0.311911E+11 | 0.00 | 0.00 | 13067590.61 | 0.00 | 0.139014E+10 | 0.210453E+11 | 0.00 | 0.46 |
Annual Sum or Average | 0.101598E+12 | 0.941392E+11 | 0.00 | 0.417128E+09 | 0.551837E+09 | 0.163724E+10 | 0.236914E+12 | 0.00 | 0.66 |
Minimum of Months | 14778158.79 | 0.00 | 0.00 | 5358227.60 | 0.00 | 0.00 | 0.203027E+09 | 0.00 | 0.46 |
Maximum of Months | 0.311911E+11 | 0.329534E+11 | 0.00 | 75717123.53 | 0.300781E+09 | 0.139014E+10 | 0.404122E+11 | 0.00 | 0.91 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.116595E+10 | 0.00 | 0.00 | 8368481.14 | 0.00 | 62109364.85 | 0.639091E+10 | 0.00 | 0.84 |
February | 0.753946E+09 | 0.00 | 0.00 | 8454002.93 | 0.00 | 36721303.30 | 0.547605E+10 | 0.00 | 1.06 |
March | 0.749755E+09 | 0.00 | 0.00 | 9984894.65 | 0.00 | 16202595.14 | 0.561488E+10 | 0.00 | 1.26 |
April | 0.208755E+09 | 0.101059E+09 | 0.00 | 9816965.52 | 0.00 | 0.00 | 0.305174E+10 | 0.00 | 1.05 |
May | 63863139.37 | 0.734007E+09 | 0.00 | 5121751.14 | 109966.59 | 0.00 | 0.112217E+10 | 0.00 | 0.80 |
June | 29525396.03 | 0.162567E+10 | 0.00 | 2203845.21 | 1637131.61 | 0.00 | 0.334643E+09 | 0.00 | 0.66 |
July | 4689365.51 | 0.338745E+10 | 0.00 | 1189110.22 | 6717834.40 | 0.00 | 94433535.01 | 0.00 | 0.65 |
August | 13991223.95 | 0.213207E+10 | 0.00 | 3075153.26 | 2911338.42 | 0.00 | 0.513946E+09 | 0.00 | 0.81 |
September | 29265126.16 | 0.157295E+10 | 0.00 | 5858571.84 | 210045.16 | 0.00 | 0.988708E+09 | 0.00 | 0.86 |
October | 68968045.63 | 0.453653E+09 | 0.00 | 15749912.00 | 299000.41 | 0.00 | 0.454813E+10 | 0.00 | 1.39 |
November | 0.551747E+09 | 0.00 | 0.00 | 14399596.37 | 0.00 | 9785480.33 | 0.721899E+10 | 0.00 | 1.30 |
December | 0.139246E+10 | 0.00 | 0.00 | 7780646.44 | 0.00 | 95064663.38 | 0.626124E+10 | 0.00 | 0.80 |
Annual Sum or Average | 0.503292E+10 | 0.100069E+11 | 0.00 | 92002930.72 | 11885316.57 | 0.219883E+09 | 0.416158E+11 | 0.00 | 0.96 |
Minimum of Months | 4689365.51 | 0.00 | 0.00 | 1189110.22 | 0.00 | 0.00 | 94433535.01 | 0.00 | 0.65 |
Maximum of Months | 0.139246E+10 | 0.338745E+10 | 0.00 | 15749912.00 | 6717834.40 | 95064663.38 | 0.721899E+10 | 0.00 | 1.39 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.207623E+10 | 0.00 | 0.00 | 3317840.93 | 0.00 | 0.310025E+09 | 0.295993E+10 | 0.00 | 0.57 |
February | 0.145607E+10 | 0.00 | 0.00 | 3588482.76 | 0.00 | 0.218627E+09 | 0.270908E+10 | 0.00 | 0.73 |
March | 0.123494E+10 | 0.00 | 0.00 | 4282536.68 | 0.00 | 0.127354E+09 | 0.306287E+10 | 0.00 | 0.87 |
April | 0.401061E+09 | 95493943.05 | 0.00 | 5252317.72 | 0.00 | 1758267.48 | 0.186097E+10 | 0.00 | 0.79 |
May | 93958357.99 | 0.687030E+09 | 0.00 | 3148615.01 | 1113200.01 | 0.00 | 0.706989E+09 | 0.00 | 0.65 |
June | 36946495.06 | 0.155797E+10 | 0.00 | 1546969.91 | 993568.99 | 0.00 | 0.203714E+09 | 0.00 | 0.57 |
July | 7633488.65 | 0.307495E+10 | 0.00 | 876870.34 | 7929860.07 | 0.00 | 68943643.17 | 0.00 | 0.57 |
August | 28981359.82 | 0.194664E+10 | 0.00 | 2147270.20 | 1779880.08 | 0.00 | 0.371997E+09 | 0.00 | 0.68 |
September | 39123140.84 | 0.141914E+10 | 0.00 | 4080626.66 | 447928.33 | 0.00 | 0.691509E+09 | 0.00 | 0.72 |
October | 0.237457E+09 | 0.391964E+09 | 0.00 | 10273441.68 | 0.00 | 0.00 | 0.316485E+10 | 0.00 | 1.05 |
November | 0.108508E+10 | 0.00 | 0.00 | 8378415.09 | 0.00 | 70823285.36 | 0.448469E+10 | 0.00 | 0.94 |
December | 0.233848E+10 | 0.00 | 0.00 | 2920758.65 | 0.00 | 0.370210E+09 | 0.280807E+10 | 0.00 | 0.54 |
Annual Sum or Average | 0.903595E+10 | 0.917319E+10 | 0.00 | 49814145.64 | 12264437.46 | 0.109880E+10 | 0.230936E+11 | 0.00 | 0.72 |
Minimum of Months | 7633488.65 | 0.00 | 0.00 | 876870.34 | 0.00 | 0.00 | 68943643.17 | 0.00 | 0.54 |
Maximum of Months | 0.233848E+10 | 0.307495E+10 | 0.00 | 10273441.68 | 7929860.07 | 0.370210E+09 | 0.448469E+10 | 0.00 | 1.05 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:04
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |