Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885
Simulation Timestamp: 2020-06-03 19:13:49
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1200.73 | 523.42 | 523.42 |
Net Site Energy | 1200.73 | 523.42 | 523.42 |
Total Source Energy | 2957.13 | 1289.07 | 1289.07 |
Net Source Energy | 2957.13 | 1289.07 | 1289.07 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 309.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 25.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 349.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 59.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 165.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 96.58 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 794.78 | 405.95 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 309.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 25.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 349.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 59.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 165.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 96.58 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 178.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 83.00 | 176.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 346.46 | 176.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 178.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 83.00 | 176.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 85.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 346.46 | 176.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 794.783 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 794.783 | 100.00 |
Total On-Site and Utility Electric Sources | 794.783 | 100.00 |
Total Electricity End Uses | 794.783 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 922.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13 |
RunPeriod | RUNPERIOD 1 |
Weather File | William R Fairchild WA USA TMY3 WMO#=727885 |
Latitude [deg] | 48.12 |
Longitude [deg] | -123.5 |
Elevation [m] | 91.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 23.78 |
Skylight-Roof Ratio [%] | 1.04 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 6.8133 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 15.4032 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 15.4032 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 15.4032 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 8.7188 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 13.9457 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 13.9457 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 21-JUL-16:00 | 10-JAN-07:10 | - | - | - | 13-SEP-11:09 |
Heating | 0.00 | 157311.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 21793.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 26644.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 7095.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 4565.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 66304.31 | 161876.67 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 157311.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 21793.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 26644.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 7095.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 4565.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 335.35 | 0.00 | 0.00 | 0.00 |
Cooling | 79.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1106.72 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 189.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 523.42 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 104.70 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2517.08 | 440.05 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 146.19 | 0.00 | 0.00 | 0.00 |
Cooling | 34.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 482.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 82.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 228.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 45.64 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1097.25 | 191.83 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 146.19 | 0.00 | 0.00 | 0.00 |
Cooling | 34.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 482.44 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 82.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 228.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 45.64 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1097.25 | 191.83 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 1.52 |
CORE_RETAIL DIRECT AIR | 6.96 |
POINT_OF_SALE DIRECT AIR | 1.18 |
FRONT_RETAIL DIRECT AIR | 0.955110 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 1.66 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 1.66 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 38345.59 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 41707.56 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 217175.14 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 32433.81 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 27187.69 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 1.52 | 1.52 | 1.52 | 1.52 | 1.57 | 1.57 | 1.00 | 0.963313 | 1.57 |
PSZ-AC:2 | 6.96 | 6.96 | 6.96 | 6.96 | 7.18 | 7.18 | 1.00 | 0.969774 | 7.18 |
PSZ-AC:3 | 1.18 | 1.18 | 1.18 | 1.18 | 1.18 | 1.18 | 1.00 | 1.00 | 1.18 |
PSZ-AC:4 | 0.955110 | 0.955110 | 0.955110 | 0.955110 | 0.955110 | 0.955110 | 1.00 | 1.00 | 0.955110 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 1.57 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 7.18 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.18 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 0.955110 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 1.57 | 1.57 | 1.57 | 1.04 | 27465.05 | 41707.56 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 7.18 | 7.18 | 7.18 | 4.74 | 120378.03 | 217175.14 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.18 | 1.18 | 1.18 | 0.782009 | 19613.69 | 32433.81 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 0.955110 | 0.955110 | 0.955110 | 0.955110 | 15810.46 | 27187.69 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 1.57 | 0.787360 | 1.05 | 26067.21 | 27465.05 | 13732.52 | 13732.52 | 0.779943 | 0.779940 | 0.779940 | 0.779940 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 7.18 | 3.59 | 4.79 | 118874.52 | 120378.03 | 60189.01 | 60189.01 | 0.794063 | 0.794060 | 0.794060 | 0.794060 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.18 | 0.592430 | 0.789907 | 19613.64 | 19613.69 | 9806.84 | 9806.84 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 0.955110 | 0.477555 | 0.636740 | 15810.46 | 15810.46 | 7905.23 | 7905.23 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.57 | 1685.03 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 7.18 | 12098.28 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.18 | 1311.83 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.955110 | 1057.46 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.30 | 6.70 | 4.10 | 4.20 | 4.20 | 5.90 | 9.00 | 10.00 | 13.30 | 15.00 | 15.70 | 13.40 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | William R Fairchild WA USA TMY3 WMO#=727885 | 48.12 | -123.50 | -8.00 | 91.00 | 100237 | 1.1914 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.23 | 11.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 6.813 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.883 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 15.403 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 18.633 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 15.403 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 36.923 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 15.403 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 18.633 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 8.719 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8.719 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 2588.290 | 6.813 | 42.195 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2588.290 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 24652.487 | 15.403 | 95.392 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 24652.487 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2322.950 | 15.403 | 95.392 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2322.950 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2322.950 | 15.403 | 95.392 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2322.950 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 104.625 | 8.719 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 104.625 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.092 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.195 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.5534 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.1725 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.3437E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.1989 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.1989 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.3274 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4781 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8365 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.640 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.721 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 29.02 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.950 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.950 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.978 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.0917746 | 2.0917746 | 2.0917746 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.1954460 | 1.1954460 | 1.1954460 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
21 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
22 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
23 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
24 | 9 | 0.29758781E-14 | -0.29065710E-15 | -0.16717921E-09 | -0.54082436E-16 |
25 | 8 | 0.24322757E-07 | 0.75510264E-13 | 0.40304845E-03 | -0.27655812E-09 |
26 | 7 | -0.12993629E-01 | 0.38338009E-08 | -0.24168191E-01 | 0.14774231E-03 |
27 | 6 | 0.42578349 | 0.13225368E-05 | 0.48945559 | -0.49886206E-02 |
28 | 5 | -5.3899404 | 0.49024379E-04 | -4.5744615 | 0.65656055E-01 |
29 | 4 | 33.884590 | 0.39840510E-03 | 21.960611 | -0.43383013 |
30 | 3 | -113.10176 | 0.86320527E-03 | -56.652426 | 1.5422922 |
31 | 2 | 198.98955 | 0.48301085E-03 | 78.818690 | -2.9302292 |
32 | 1 | -171.85079 | 0.51313109E-04 | -55.530381 | 2.7576150 |
33 | 0 | 57.057407 | 0.29052359E-06 | 15.514123 | |
34 | 7 | -0.24541788E-08 | -0.10674912E-14 | 0.56595312E-14 | -0.88347803E-16 |
35 | 6 | 0.48874313E-05 | 0.32994277E-08 | 0.31919810E-02 | -0.26777012E-04 |
36 | 5 | -0.34768456E-03 | 0.19525666E-05 | -0.22384457 | 0.19572094E-02 |
37 | 4 | 0.79733842E-02 | 0.88847046E-04 | 4.8315443 | -0.45284193E-01 |
38 | 3 | -0.69943606E-01 | 0.70626596E-03 | -38.032707 | 0.39877855 |
39 | 2 | 0.24825401 | 0.11745943E-02 | 116.50592 | -1.4182332 |
40 | 1 | -0.35825340 | 0.35768630E-03 | -143.92024 | 2.0492525 |
41 | 0 | 0.17465044 | 0.86763216E-05 | 60.838472 | |
42 | 7 | -0.12489162E-07 | 0.28466235E-14 | -0.17145271E-13 | 0.26119495E-15 |
43 | 6 | 0.18517441E-05 | 0.69460444E-09 | 0.32027219E-02 | -0.26867115E-04 |
44 | 5 | -0.89695516E-04 | 0.39969105E-06 | -0.22445454 | 0.19625936E-02 |
45 | 4 | 0.17714562E-02 | 0.17921615E-04 | 4.8416944 | -0.45381772E-01 |
46 | 3 | -0.14613545E-01 | 0.14074818E-03 | -38.089997 | 0.39941188 |
47 | 2 | 0.50542763E-01 | 0.23137019E-03 | 116.61736 | -1.4197240 |
48 | 1 | -0.72070041E-01 | 0.69440628E-04 | -143.98582 | 2.0503304 |
49 | 0 | 0.34918756E-01 | 0.16519960E-05 | 60.838472 | |
50 | 7 | -0.21220229E-08 | -0.69274912E-15 | 0.44419095E-14 | -0.59983029E-16 |
51 | 6 | 0.55968656E-05 | 0.38086687E-08 | 0.31899104E-02 | -0.26759642E-04 |
52 | 5 | -0.40060043E-03 | 0.22548894E-05 | -0.22372688 | 0.19561706E-02 |
53 | 4 | 0.92029272E-02 | 0.10262663E-03 | 4.8295842 | -0.45265352E-01 |
54 | 3 | -0.80779323E-01 | 0.81597308E-03 | -38.021635 | 0.39865617 |
55 | 2 | 0.28678301 | 0.13572938E-02 | 116.48438 | -1.4179450 |
56 | 1 | -0.41389855 | 0.41342724E-03 | -143.90756 | 2.0490440 |
57 | 0 | 0.20178854 | 0.10024527E-04 | 60.838472 | |
58 | 7 | -0.21220229E-08 | -0.69274912E-15 | 0.44419095E-14 | -0.59983029E-16 |
59 | 6 | 0.55968656E-05 | 0.38086687E-08 | 0.31899104E-02 | -0.26759642E-04 |
60 | 5 | -0.40060043E-03 | 0.22548894E-05 | -0.22372688 | 0.19561706E-02 |
61 | 4 | 0.92029272E-02 | 0.10262663E-03 | 4.8295842 | -0.45265352E-01 |
62 | 3 | -0.80779323E-01 | 0.81597308E-03 | -38.021635 | 0.39865617 |
63 | 2 | 0.28678301 | 0.13572938E-02 | 116.48438 | -1.4179450 |
64 | 1 | -0.41389855 | 0.41342724E-03 | -143.90756 | 2.0490440 |
65 | 0 | 0.20178854 | 0.10024527E-04 | 60.838472 | |
66 | 7 | -0.12723796E-08 | -0.15085021E-15 | 0.80954726E-14 | -0.10933793E-15 |
67 | 6 | 0.91456241E-05 | 0.63025983E-08 | 0.31797574E-02 | -0.26674470E-04 |
68 | 5 | -0.66211654E-03 | 0.37378006E-05 | -0.22314974 | 0.19510765E-02 |
69 | 4 | 0.15256371E-01 | 0.17022008E-03 | 4.8199703 | -0.45172938E-01 |
70 | 3 | -0.13404479 | 0.13543778E-02 | -37.967318 | 0.39805580 |
71 | 2 | 0.47605416 | 0.22539081E-02 | 116.37865 | -1.4165309 |
72 | 1 | -0.68716389 | 0.68732095E-03 | -143.84532 | 2.0480210 |
73 | 0 | 0.33503722 | 0.16534103E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 30 | 1 | VerySmooth | 2.159 | 0.394 | 0.315 | 0.401 |
2 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 31 | 1 | VerySmooth | 4.262 | 0.604 | 0.475 | 0.601 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 3.45900E-002 | 0.31435 | 0.47939 | 0.47939 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11893 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.47441 | 0.15233 | 0.15233 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 2.99465E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1913 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.249 | 6.557E-004 | 2.976E-004 | 0.387 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.204 | 1.274E-004 | 1.036E-004 | 7.518E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 1.387E-002 | 1.156E-003 | 3.812E-004 | 0.682 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.937 | 7.811E-002 | 2.576E-002 | 46.096 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 17865.59824 | 21438.71789 | 1.26413 | 1.51695 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 19.66600 | 8.38408E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 20780.49293 | 24936.59151 | 0.88301 | 1.05961 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 81718.05032 | 98061.66039 | 5.80345 | 6.96414 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 19.66600 | 8.38408E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 54833.12142 | 65799.74570 | 2.29837 | 2.75805 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 13312.78841 | 15975.34609 | 0.98739 | 1.18486 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 26.09667 | 8.38408E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 10108.38827 | 12130.06592 | 0.43137 | 0.51765 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 10731.27495 | 12877.52994 | 0.79592 | 0.95511 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 26.17250 | 8.38408E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 10105.01654 | 12126.01984 | 0.43123 | 0.51747 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -4.30000 | 2.65759E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.40000 | 8.38408E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 31928.89092 | 38314.66910 | 1.38698 | 1.66438 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 19886.31 | 1.57472 | 1.57472 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 31237.63 | 1.05961 | 1.05961 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 93251.08 | 7.18121 | 7.18121 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 120245.28 | 2.75805 | 2.75805 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 16215.00 | 1.18486 | 1.18486 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 17198.85 | 0.51765 | 0.51765 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 13170.03 | 0.95511 | 0.95511 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 17194.83 | 0.51747 | 0.51747 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.51695 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 6.96414 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.18486 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.95511 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.66438 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 1.66438 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 38345.59305 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.51695 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.51695 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.51695 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.51695 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.57472 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.57472 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.96331 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 6.96414 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 6.96414 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.96414 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 6.96414 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 7.18121 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 7.18121 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.96977 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.18486 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.18486 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.18486 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.18486 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.18486 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.18486 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.95511 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.95511 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.95511 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.95511 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.95511 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.95511 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 1.57472 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 7.18121 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.18486 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 0.95511 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.57472 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.57472 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.57472 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.57472 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.03932 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.57472 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.78736 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.04981 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 26067.20742 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27465.05000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13732.52500 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 13732.52500 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.77994 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.77994 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.77994 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.77994 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27465.05000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 41707.56279 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.57472 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1685.02774 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 41707.56279 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 7.18121 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 7.18121 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 7.18121 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 7.18121 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 4.73960 |
74 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 7.18121 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 3.59061 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 4.78747 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 118874.52409 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 120378.03000 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 60189.01500 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 60189.01500 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79406 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79406 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79406 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79406 |
85 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 120378.03000 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 217175.14459 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
89 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 7.18121 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 12098.28223 |
91 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 217175.14459 |
92 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.18486 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
94 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.18486 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.18486 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.18486 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.78201 |
98 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.18486 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.59243 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.78991 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 19613.64013 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 19613.69000 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 9806.84500 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 9806.84500 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
109 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 19613.69000 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 32433.81206 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
113 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.18486 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1311.83113 |
115 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 32433.81206 |
116 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.95511 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.95511 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.95511 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.95511 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.95511 |
122 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.95511 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.47756 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.63674 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15810.46184 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15810.46000 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7905.23000 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 7905.23000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
133 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15810.46000 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27187.68620 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
137 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.95511 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1057.45803 |
139 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27187.68620 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 26230.1 | 11.23 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 114749.1 | 12.51 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 18685.1 | 94.89 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 15061.9 | 137.26 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.172 | 0.166 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.092 | 2.092 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 3.437E-002 | 3.409E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 1576.70 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | N/A | 4.262 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.199 | 0.190 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.199 | 0.190 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.553 | 0.511 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.327 | 0.303 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 7 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 5.1417988591E-002 | 0.2122099859 | Pass | Pass | 0.1704128639 | 1.4215898811 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 3.1997531416E-002 | 0.1351199582 | Pass | Pass | 0.1985424919 | 0.6370222202 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 4.1374484452E-002 | 0.1683146615 | Pass | Pass | 0.3531791551 | 2.3792653901 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 4.4815219237E-002 | 0.1886677774 | Pass | Pass | 0.2567759717 | 1.1819137542 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 9.7757780560E-002 | 0.3913641704 | Pass | Pass | 7.1587550043E-002 | 0.5367394311 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | -4.30 | 0.00 | -4.30 | Wetbulb [C] | 1.20 | 110.00 |
WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.40 | 9.10 | 17.00 | Wetbulb [C] | 2.10 | 90.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 1600.48 | 1576.70 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.511 | 0.553 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.23 | 0.182 | 0.186 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.172 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.034 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.199 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.199 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.327 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_0.75_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 4.262 | 0.604 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.38_SHGC_0.4 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.159 | 0.394 | 0.401 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.38_SHGC_0.4 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.159 | 0.394 | 0.401 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.38_SHGC_0.4 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.159 | 0.394 | 0.401 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 107.72 | 2.623 | 0.440 | 0.445 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 107.72 | 2.623 | 0.440 | 0.445 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 1.593 | 2.092 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 6.8133 | 379.89 | 2588.29 | LightsWired | BLDG_LIGHT_BACK_SCH | 60.89 | 168.00 | 60.06 | 0.0000 | Y | 29.18 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 15.4032 | 1600.48 | 24652.49 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 56.06 | 0.0000 | Y | 259.41 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 15.4032 | 150.81 | 2322.95 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 29.76 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 15.4032 | 150.81 | 2322.95 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 29.76 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 8.7188 | 12.00 | 104.63 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 1.34 |
Interior Lighting Total | 13.9457 | 2293.99 | 31991.30 | 349.45 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 24652.49 | 6163.12 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 24652.49 | 6163.12 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 238.00 | AstronomicalClock | - | 42.50 | 42.50 | 1.90 | |
EXTERIOR_LIGHTS_B | 4328.05 | AstronomicalClock | - | 83.54 | 71.23 | 57.87 | |
Exterior Lighting Total | 4566.05 | 59.77 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27465.05 | 21421.09 | 6043.96 | 0.78 | 3.80 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 120378.03 | 95587.38 | 24790.65 | 0.79 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 19613.69 | 15664.67 | 3949.02 | 0.80 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15810.46 | 12627.18 | 3183.28 | 0.80 | 4.12 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 26230.1 | 11.23 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 114749.1 | 12.51 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 18685.1 | 94.89 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 15061.9 | 137.26 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 38345.59 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 41707.56 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 217175.14 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 32433.81 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27187.69 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.58 | 622.50 | 1.66 | 1780.96 | 1070.05 | 1.00 | 1.33 | General | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.57 | 1685.03 | 1070.05 | 1.00 | 1.35 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1018.41 | 7.18 | 12098.28 | 1684.71 | 1.00 | 1.16 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.18 | 1311.83 | 1107.16 | 1.00 | 1.36 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.96 | 1057.46 | 1107.16 | 1.00 | 1.41 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 17865.60 | 21438.72 | 56.43 | 1.264 | 1.517 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 23.89 | 23.88 | 0.01064 | 19.67 | 0.00838 | 0.232 | 0.00 |
CORE_RETAIL | 81718.05 | 98061.66 | 61.27 | 5.803 | 6.964 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | 23.89 | 23.88 | 0.01003 | 19.67 | 0.00838 | 1.890 | 0.00 |
POINT_OF_SALE | 13312.79 | 15975.35 | 105.93 | 0.987 | 1.185 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 23.89 | 23.89 | 0.00890 | 26.10 | 0.00838 | 0.178 | 0.00 |
FRONT_RETAIL | 10731.27 | 12877.53 | 85.39 | 0.796 | 0.955 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 23.89 | 23.89 | 0.00900 | 26.17 | 0.00838 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.93 | 100.00 | 0.00001 | 26.40 | 0.00838 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 20780.49 | 24936.59 | 65.64 | 0.883 | 1.060 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00762 | -4.30 | 0.00266 | 0.232 | 0.00 |
CORE_RETAIL | 54833.12 | 65799.75 | 41.11 | 2.298 | 2.758 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00785 | -4.30 | 0.00266 | 1.890 | 0.00 |
POINT_OF_SALE | 10108.39 | 12130.07 | 80.43 | 0.431 | 0.518 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00779 | -4.30 | 0.00266 | 0.178 | 0.00 |
FRONT_RETAIL | 10105.02 | 12126.02 | 80.41 | 0.431 | 0.517 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00779 | -4.30 | 0.00266 | 0.178 | 0.00 |
FRONT_ENTRY | 31928.89 | 38314.67 | 3192.89 | 1.387 | 1.664 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.04 | 0.00574 | -4.30 | 0.00266 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 1.57 | 1.57 | 1.06 | 1.06 | 1.5747 | 1.5170 | 1.5747 | 0.9633 | 1.0000 |
PSZ-AC:2 | 7.18 | 7.18 | 2.76 | 2.76 | 7.1812 | 6.9641 | 7.1812 | 0.9698 | 1.0000 |
PSZ-AC:3 | 1.18 | 1.18 | 0.52 | 0.52 | 1.1849 | 1.1849 | 1.1849 | 1.0000 | 1.0000 |
PSZ-AC:4 | 0.96 | 0.96 | 0.52 | 0.52 | 0.9551 | 0.9551 | 0.9551 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 38345.593 | 38345.593 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 38345.59 | 38345.59 | 1.664376 | 20.82 | 12.49 | 0.00571136 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 0.0000 | 21.04 | 0.00573759 | 36.7493 | 38314.67 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 13732.525 | 0.000 | 1.574720 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 13732.52 | 10715.62 | 1.574720 | 23.35 | 17.17 | 0.00984527 | 12.80 | 12.00 | 0.00850000 | 20.24 | 0.00838408 | 14.80 | 14.7052 | 23.88 | 0.01064354 | 56.8928 | 17865.60 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 41707.563 | 41707.563 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 41707.56 | 41707.56 | 1.574723 | 15.37 | 11.08 | 0.00653904 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 14.7052 | 21.11 | 0.00762451 | 48.4697 | 20780.49 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 60189.015 | 0.000 | 7.181210 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 60189.01 | 54799.45 | 7.181210 | 24.56 | 16.90 | 0.00901734 | 12.80 | 12.00 | 0.00850000 | 26.25 | 0.00838408 | 16.95 | 26.3216 | 23.88 | 0.01002972 | 53.6592 | 81718.05 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 217175.145 | 217175.145 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 217175.14 | 217175.14 | 7.181206 | 3.58 | 2.71 | 0.00429020 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 26.3217 | 21.11 | 0.00784615 | 49.8587 | 54833.12 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 9806.845 | 0.000 | 1.184860 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 9806.84 | 9220.96 | 1.184860 | 24.23 | 16.62 | 0.00882589 | 12.80 | 12.00 | 0.00850000 | 26.17 | 0.00838408 | 16.92 | 15.0322 | 23.89 | 0.00890408 | 47.7113 | 13312.46 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 32433.812 | 32433.812 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 32433.81 | 32433.81 | 1.184863 | 12.25 | 9.15 | 0.00602208 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 15.0322 | 21.11 | 0.00778699 | 49.4890 | 10108.39 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 7905.230 | 0.000 | 0.955110 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 7905.23 | 7355.50 | 0.955110 | 24.33 | 16.71 | 0.00888622 | 12.80 | 12.00 | 0.00850000 | 26.25 | 0.00838408 | 16.95 | 18.6482 | 23.89 | 0.00900134 | 48.2251 | 10721.43 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 27187.686 | 27187.686 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 27187.69 | 27187.69 | 0.955110 | 12.24 | 9.15 | 0.00602126 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 18.6482 | 21.11 | 0.00778665 | 49.4869 | 10105.02 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 38345.593 | 38345.593 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 1.664376 | 1.98289134 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 38345.59 | 38345.59 | 1.0000 | 1.98289134 | 1.664376 | 20.82 | 12.49 | 0.00571136 | 35425.5 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 38345.59 | -4.30 | 0.00265759 | -4.30 | 0.00000000 | 0.0000 | 21.05 | 0.00573759 | 21.04 | 0.00573759 | 36.7493 | 38314.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 13732.525 | 0.000 | 1.574720 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.1419 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 13732.52 | 10715.62 | 1.0000 | 1.87607733 | 1.574720 | 23.35 | 17.17 | 0.00984527 | 48511.4 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 13732.52 | 20.24 | 0.00838408 | 14.80 | 0.23156651 | 14.7052 | 23.88 | 0.01009719 | 23.88 | 0.01064354 | 56.8928 | 17865.60 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 41707.563 | 41707.563 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.574723 | 1.87608056 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 41707.56 | 41707.56 | 1.0000 | 1.87608056 | 1.574723 | 15.37 | 11.08 | 0.00653904 | 31989.9 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 41707.56 | -4.30 | 0.00265759 | -4.30 | 0.23156651 | 14.7052 | 20.88 | 0.00762451 | 21.11 | 0.00762451 | 48.4697 | 20780.49 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 60189.015 | 0.000 | 7.181210 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6028 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 08:20:00 | 60189.01 | 54799.45 | 1.0000 | 8.55549260 | 7.181210 | 24.56 | 16.90 | 0.00901734 | 47644.0 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 60189.01 | 26.25 | 0.00838408 | 16.95 | 1.89021192 | 26.3216 | 23.89 | 0.00927027 | 23.88 | 0.01002972 | 53.6592 | 81718.05 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 217175.145 | 217175.145 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 7.181206 | 8.55548738 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 217175.14 | 217175.14 | 1.0000 | 8.55548738 | 7.181206 | 3.58 | 2.71 | 0.00429020 | 14357.6 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 217175.14 | -4.30 | 0.00265759 | -4.30 | 1.89021192 | 26.3217 | 20.75 | 0.00784615 | 21.11 | 0.00784615 | 49.8587 | 54833.12 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 9806.845 | 0.000 | 1.184860 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.2469 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 9806.84 | 9220.96 | 1.0000 | 1.41160904 | 1.184860 | 24.23 | 16.62 | 0.00882589 | 46819.4 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9806.84 | 26.17 | 0.00838408 | 16.92 | 0.17811053 | 15.0322 | 23.89 | 0.00890406 | 23.89 | 0.00890408 | 47.7113 | 13312.46 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 32433.812 | 32433.812 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.184863 | 1.41161230 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 32433.81 | 32433.81 | 1.0000 | 1.41161230 | 1.184863 | 12.25 | 9.15 | 0.00602208 | 27504.1 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 32433.81 | -4.30 | 0.00265759 | -4.30 | 0.17811053 | 15.0322 | 20.93 | 0.00778699 | 21.11 | 0.00778699 | 49.4890 | 10108.39 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 7905.230 | 0.000 | 0.955110 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.3590 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:30:00 | 7905.23 | 7355.50 | 1.0000 | 1.13789132 | 0.955110 | 24.33 | 16.71 | 0.00888622 | 47072.2 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 7905.23 | 26.25 | 0.00838408 | 16.95 | 0.17811053 | 18.6482 | 23.89 | 0.00900145 | 23.89 | 0.00900134 | 48.2251 | 10721.43 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27187.686 | 27187.686 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.955110 | 1.13789095 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 27187.69 | 27187.69 | 1.0000 | 1.13789095 | 0.955110 | 12.24 | 9.15 | 0.00602126 | 27499.0 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27187.69 | -4.30 | 0.00265759 | -4.30 | 0.17811053 | 18.6482 | 20.93 | 0.00778665 | 21.11 | 0.00778665 | 49.4869 | 10105.02 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC:1_OA_CONTROLLER | DifferentialDryBulb | 0.23 | 1.57 | - | |||
PSZ-AC:2_OA_CONTROLLER | DifferentialDryBulb | 1.89 | 7.18 | - | |||
PSZ-AC:3_OA_CONTROLLER | DifferentialDryBulb | 0.18 | 1.18 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 998.33 | 3958.33 | 868.83 |
CORE_RETAIL | 1055.33 | 3362.83 | 144.33 |
POINT_OF_SALE | 1436.00 | 2918.67 | 280.17 |
FRONT_RETAIL | 1460.17 | 3351.50 | 606.50 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 2099.33 | 3962.67 | 922.33 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 0.00 | 0.00 | 0.00 | 0.00 |
FRONT_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | 0.83 | 0.00 | 0.00 | 0.00 |
Facility | 0.83 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.47 | 61.34 | 2317.33 | 0.502 | 0.017 | 0.000 | 0.000 |
CORE_RETAIL | 128.37 | 258.43 | 9762.95 | 0.820 | 0.003 | 0.000 | 0.000 |
POINT_OF_SALE | 12.10 | 24.35 | 919.94 | 1.135 | 0.018 | 0.000 | 0.000 |
FRONT_RETAIL | 12.10 | 24.35 | 919.94 | 0.707 | 0.018 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.47 | 61.34 | 2317.33 | 0.353 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 128.37 | 258.43 | 9762.95 | 0.684 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.10 | 24.35 | 919.94 | 0.684 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.10 | 24.35 | 919.94 | 0.684 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
Electricity:Building | 544.61 | 2983.86 | 02-APR-07:20 | 39264.11 | 02-JAN-09:10 |
Electricity:Zone:BACK_SPACE | 79.17 | 589.27 | 01-JAN-00:10 | 4789.50 | 02-JAN-09:10 |
InteriorLights:Electricity | 349.46 | 1188.69 | 02-APR-07:20 | 28493.07 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:BACK_SPACE | 29.18 | 129.41 | 01-JAN-00:10 | 2030.36 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 349.46 | 1188.69 | 02-APR-07:20 | 28493.07 | 02-JAN-09:10 |
Electricity:Zone:CORE_RETAIL | 343.71 | 1597.18 | 02-APR-07:20 | 26839.84 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 259.41 | 821.75 | 02-APR-07:20 | 22187.24 | 02-JAN-09:10 |
Electricity:Zone:POINT_OF_SALE | 82.68 | 602.96 | 01-JAN-00:10 | 5011.54 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 29.76 | 116.15 | 01-JAN-00:10 | 2090.65 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 37.71 | 189.21 | 01-JAN-00:10 | 2529.06 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 29.76 | 116.15 | 01-JAN-00:10 | 2090.65 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 1.34 | 5.23 | 01-JAN-00:10 | 94.16 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 1.34 | 5.23 | 01-JAN-00:10 | 94.16 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
ElectricityPurchased:Plant | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
Cogeneration:ElectricityPurchased | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
ElectricityNet:Plant | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
Cogeneration:ElectricityNet | 794.78 | 3189.30 | 07-MAY-06:50 | 66304.31 | 21-JUL-17:00 |
Electricity:HVAC | 190.41 | 0.00 | 01-JAN-00:10 | 31381.20 | 22-JUL-15:00 |
Fans:Electricity | 165.27 | 0.00 | 01-JAN-00:10 | 11990.59 | 10-JAN-07:10 |
General:Fans:Electricity | 165.27 | 0.00 | 01-JAN-00:10 | 11990.59 | 10-JAN-07:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 25.13 | 0.00 | 01-JAN-00:10 | 23978.02 | 22-JUL-15:00 |
ExteriorLights:Electricity | 59.77 | 0.00 | 01-JAN-08:20 | 4566.05 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 59.77 | 0.00 | 01-JAN-08:20 | 4566.05 | 01-JAN-06:10 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 405.95 | 1862.00 | 12-AUG-08:40 | 161876.67 | 10-JAN-07:10 |
Gas:Plant | 96.58 | 1862.00 | 12-AUG-08:40 | 5104.49 | 14-FEB-12:30 |
WaterSystems:Gas | 96.58 | 1862.00 | 12-AUG-08:40 | 5104.49 | 14-FEB-12:30 |
Water Heater:WaterSystems:Gas | 96.58 | 1862.00 | 12-AUG-08:40 | 5104.49 | 14-FEB-12:30 |
Gas:HVAC | 309.37 | 0.00 | 01-JAN-00:10 | 157311.23 | 10-JAN-07:10 |
Heating:Gas | 309.37 | 0.00 | 01-JAN-00:10 | 157311.23 | 10-JAN-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 13-SEP-11:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 942.13 | 0.00 | 01-JAN-00:10 | 215761.50 | 10-JAN-07:10 |
EnergyTransfer:Building | 597.56 | 0.00 | 01-JAN-00:10 | 95162.44 | 01-JAN-09:10 |
EnergyTransfer:Zone:BACK_SPACE | 52.55 | 0.00 | 01-JAN-00:10 | 18346.06 | 10-JAN-06:10 |
Heating:EnergyTransfer | 121.71 | 0.00 | 01-JAN-00:10 | 77263.29 | 26-DEC-07:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 10.40 | 0.00 | 01-JAN-00:10 | 18346.06 | 10-JAN-06:10 |
Cooling:EnergyTransfer | 475.85 | 0.00 | 01-JAN-00:10 | 68488.86 | 22-JUL-15:50 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 42.15 | 0.00 | 01-JAN-00:10 | 9296.34 | 22-JUL-16:00 |
EnergyTransfer:Zone:CORE_RETAIL | 352.66 | 0.00 | 01-JAN-00:10 | 66019.07 | 01-JAN-09:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 9.40 | 0.00 | 01-JAN-00:10 | 50333.02 | 02-JAN-07:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 343.26 | 0.00 | 01-JAN-00:10 | 55355.36 | 14-JUN-06:10 |
EnergyTransfer:Zone:POINT_OF_SALE | 59.92 | 0.00 | 01-JAN-00:10 | 9919.69 | 12-SEP-14:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 1.79 | 0.00 | 01-JAN-00:10 | 6151.93 | 10-JAN-07:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 58.13 | 0.00 | 01-JAN-00:10 | 9919.69 | 12-SEP-14:10 |
EnergyTransfer:Zone:FRONT_RETAIL | 36.55 | 0.00 | 01-JAN-00:10 | 9404.75 | 18-DEC-06:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 4.24 | 0.00 | 01-JAN-00:10 | 8451.46 | 18-DEC-06:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 32.31 | 0.00 | 01-JAN-00:10 | 7676.50 | 12-SEP-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 95.88 | 0.00 | 01-JAN-00:10 | 30681.06 | 11-JAN-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 95.88 | 0.00 | 01-JAN-00:10 | 30681.06 | 11-JAN-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 344.57 | 0.00 | 01-JAN-00:10 | 125848.98 | 10-JAN-07:10 |
HeatingCoils:EnergyTransfer | 247.49 | 0.00 | 01-JAN-00:10 | 125848.98 | 10-JAN-07:10 |
CoolingCoils:EnergyTransfer | 97.08 | 0.00 | 01-JAN-00:10 | 92850.45 | 22-JUL-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 10.398 | -42.150 | 0.000 | 0.000 | 40.086 | 29.179 | 49.992 | 0.000 | 0.000 | 0.004 | 0.000 | 0.000 | 0.000 | 0.000 | -9.802 | -77.708 |
CORE_RETAIL | 0.000 | 0.000 | 9.399 | -343.262 | 0.000 | 0.000 | 168.939 | 259.411 | 84.299 | 45.670 | 0.000 | 0.003 | 0.000 | 0.000 | -26.748 | 0.000 | -8.668 | -189.044 |
POINT_OF_SALE | 0.000 | 0.000 | 1.791 | -58.125 | 0.000 | 0.000 | 15.376 | 29.762 | 52.922 | 30.280 | 0.000 | 0.002 | 0.001 | 0.000 | -20.379 | 0.000 | -4.561 | -47.068 |
FRONT_RETAIL | 0.000 | 0.000 | 4.241 | -32.312 | 0.000 | 0.000 | 15.769 | 29.762 | 7.943 | 30.419 | 0.000 | 0.002 | 0.003 | 0.000 | -19.591 | 0.000 | -4.320 | -31.913 |
FRONT_ENTRY | 95.883 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.340 | 0.000 | 6.249 | 0.000 | 0.002 | 0.914 | 0.000 | -3.935 | 0.000 | -100.454 | -0.000 |
Total Facility | 95.883 | 0.000 | 25.829 | -475.849 | 0.000 | 0.000 | 240.170 | 349.455 | 195.156 | 112.619 | 0.000 | 0.013 | 0.918 | 0.000 | -70.653 | 0.000 | -127.804 | -345.733 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 24-JUL-06:02 | 0.00 | 0.00 | 0.00 | -27896.06 | 0.00 | 0.00 | 412.49 | 451.19 | 1226.28 | 0.00 | 0.00 | 0.00 | 25980.81 | 0.00 | -0.00 | 0.00 | -174.72 | 0.00 |
CORE_RETAIL | 25-AUG-06:03 | 0.00 | 0.00 | 0.00 | -146324.15 | 0.00 | 0.00 | 1677.28 | 4930.50 | 2067.82 | 0.00 | 0.00 | 0.00 | 138314.54 | 0.00 | -666.00 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 12-SEP-06:02 | 0.00 | 0.00 | 0.00 | -23764.56 | 0.00 | 0.00 | 152.06 | 464.59 | 1298.17 | 0.00 | 0.00 | 0.00 | 22746.25 | 0.00 | -896.51 | 0.00 | 0.00 | 0.00 |
FRONT_RETAIL | 23-JUL-08:62 | 0.00 | 0.00 | 0.00 | -13590.47 | 0.00 | 0.00 | 159.17 | 232.29 | 146.13 | 929.26 | 0.00 | 0.00 | 12153.01 | 0.00 | -0.00 | 0.00 | -29.40 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 22-JUL-06:02 | 0.00 | 0.00 | 0.00 | -180997.71 | 0.00 | 0.00 | 2324.16 | 3165.90 | 3590.35 | 680.13 | 0.00 | 0.00 | 171394.27 | 0.00 | -20.63 | 0.00 | -136.47 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 01-JAN-08:61 | 0.00 | 0.00 | 42265.02 | 0.00 | 0.00 | 0.00 | 0.00 | 129.41 | 459.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -187.84 | -42666.45 |
CORE_RETAIL | 01-JAN-08:61 | 0.00 | 0.00 | 209354.10 | 0.00 | 0.00 | 0.00 | 0.00 | 1232.62 | 775.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1250.75 | 0.00 | -174.84 | -209936.57 |
POINT_OF_SALE | 01-JAN-08:61 | 0.00 | 0.00 | 32126.58 | 0.00 | 0.00 | 0.00 | 0.00 | 116.15 | 486.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -982.38 | 0.00 | -91.57 | -31655.60 |
FRONT_RETAIL | 01-JAN-08:61 | 0.00 | 0.00 | 24409.46 | 0.00 | 0.00 | 0.00 | 0.00 | 116.15 | 73.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -948.84 | 0.00 | -85.90 | -23563.93 |
FRONT_ENTRY | 11-JAN-18:00 | 30676.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 94.16 | 0.00 | 0.00 | 0.00 | 0.00 | 261.26 | 0.00 | -380.12 | 0.00 | -30652.25 | 0.00 |
Total Facility | 01-JAN-08:61 | 4616.08 | 0.00 | 308155.16 | 0.00 | 0.00 | 0.00 | 0.00 | 1599.57 | 1795.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3375.61 | 0.00 | -2809.97 | -309980.40 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.5170 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.5747 | 0.1471 | 1.0000 | 0.2316 | 0.1471 | ||
PSZ-AC:2 | 6.9641 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.1812 | 0.2632 | 1.0000 | 1.8902 | 0.2632 | ||
PSZ-AC:3 | 1.1849 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1849 | 0.1503 | 1.0000 | 0.1781 | 0.1503 | ||
PSZ-AC:4 | 0.9551 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.9551 | 0.1865 | 1.0000 | 0.1781 | 0.1865 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.5170 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.5170 | 1.0000 | 1.0000 | 0.2316 | 0.1527 | ||
PSZ-AC:2 | 6.9641 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 6.9641 | 1.0000 | 1.0000 | 1.8902 | 0.2714 | ||
PSZ-AC:3 | 1.1849 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1849 | 1.0000 | 1.0000 | 0.1781 | 0.1503 | ||
PSZ-AC:4 | 0.9551 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.9551 | 1.0000 | 1.0000 | 0.1781 | 0.1865 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.5170 | 1.5170 | 1.5170 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 6.9641 | 6.9641 | 6.9641 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1849 | 1.1849 | 1.1849 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.9551 | 0.9551 | 0.9551 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.5170 | 1.5747 | 1.5170 | 1.5170 | 0.2316 | 1.0000 |
PSZ-AC:2 | 6.9641 | 7.1812 | 6.9641 | 6.9641 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1849 | 1.1849 | 1.1849 | 1.1849 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.9551 | 0.9551 | 0.9551 | 0.9551 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.5170 | 1.5170 | 1.5170 | 0.2316 | 0.2185 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 6.9641 | 6.9641 | 6.9641 | 1.8902 | 0.6853 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1849 | 1.1849 | 1.1849 | 0.1781 | 0.3441 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.9551 | 0.9551 | 0.9551 | 0.1781 | 0.3442 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.5170 | 1.5170 | 1.5170 | 1.5170 | 0.2316 | 1.0000 |
PSZ-AC:2 | 6.9641 | 6.9641 | 6.9641 | 6.9641 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1849 | 1.1849 | 1.1849 | 1.1849 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.9551 | 0.9551 | 0.9551 | 0.9551 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:49
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 309.37 | 157311.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 25.13 | 23978.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 349.46 | 28493.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 59.77 | 4566.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 165.27 | 11990.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 96.58 | 5104.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 794.78 |
Natural Gas | 0.00 | 405.95 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 1200.73 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 152.33 |
Space Heating | 0.00 |
Space Cooling | 10.96 |
Fans (All) | 72.05 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 346.46 |
Subtotal | 346.46 |
Natural Gas [MJ/m2] | |
Space Heating | 134.86 |
Service Water Heating | 42.10 |
Miscellaneous (All) | 176.96 |
Subtotal | 176.96 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 29.10 |
Space Heating | 25.76 |
Space Cooling | 2.09 |
Fans (All) | 13.76 |
Service Water Heating | 8.04 |
Receptacle Equipment | 16.25 |
Miscellaneous | 4.98 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3175. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.644448E+11 |
February | 0.000 | 0.517780E+11 |
March | 0.000 | 0.434703E+11 |
April | 0.000 | 0.130034E+11 |
May | 0.000 | 0.810749E+10 |
June | 0.000 | 0.320532E+10 |
July | 0.000 | 0.157248E+10 |
August | 0.000 | 0.468247E+09 |
September | 0.000 | 0.203745E+10 |
October | 0.000 | 0.137131E+11 |
November | 0.000 | 0.384425E+11 |
December | 0.000 | 0.691244E+11 |
Annual Sum or Average | 0.309368E+12 | |
Minimum of Months | 0.000 | 0.468247E+09 |
Maximum of Months | 0.000 | 0.691244E+11 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.135393E+10 | 5244.80 | 31-JAN-07:05 | 1.00 | 0.24 | 0.165965E+10 | 1983.05 | 19-JAN-15:50 | 8.17 | 7.45 |
February | 0.141398E+10 | 5892.42 | 24-FEB-07:05 | -1.7 | -1.7 | 0.150976E+10 | 1912.54 | 07-FEB-15:50 | 9.33 | 8.67 |
March | 0.231385E+10 | 5627.44 | 08-MAR-07:05 | -0.5 | -1.1 | 0.174914E+10 | 2108.69 | 25-MAR-13:39 | 12.67 | 9.93 |
April | 0.342757E+10 | 5633.11 | 29-APR-15:30 | 20.00 | 12.52 | 0.188626E+10 | 2451.23 | 28-APR-14:00 | 20.10 | 13.68 |
May | 0.405758E+10 | 5985.36 | 23-MAY-15:00 | 18.00 | 14.37 | 0.202755E+10 | 2451.27 | 22-MAY-14:09 | 23.17 | 15.80 |
June | 0.545385E+10 | 22801.33 | 27-JUN-06:02 | 15.00 | 15.00 | 0.217245E+10 | 2451.26 | 09-JUN-14:09 | 18.33 | 13.87 |
July | 0.652397E+10 | 27900.59 | 24-JUL-06:02 | 13.17 | 13.07 | 0.217538E+10 | 2451.25 | 18-JUL-14:00 | 18.00 | 15.44 |
August | 0.644955E+10 | 13045.01 | 15-AUG-06:02 | 17.00 | 12.89 | 0.227396E+10 | 2451.28 | 15-AUG-14:30 | 18.50 | 15.13 |
September | 0.483017E+10 | 6827.72 | 13-SEP-15:00 | 23.00 | 16.21 | 0.212493E+10 | 2451.23 | 23-SEP-10:09 | 18.00 | 14.38 |
October | 0.311940E+10 | 4587.35 | 23-OCT-06:05 | 4.00 | 3.61 | 0.187271E+10 | 2451.20 | 06-OCT-14:09 | 16.17 | 9.11 |
November | 0.215565E+10 | 5242.21 | 17-NOV-07:05 | 1.17 | 0.27 | 0.162462E+10 | 2172.77 | 10-NOV-15:50 | 11.17 | 8.40 |
December | 0.104992E+10 | 5218.13 | 08-DEC-07:05 | 1.00 | 0.59 | 0.165474E+10 | 1888.28 | 02-DEC-15:09 | 8.83 | 7.85 |
Annual Sum or Average | 0.421494E+11 | 0.227312E+11 | ||||||||
Minimum of Months | 0.104992E+10 | 4587.35 | -1.7 | -1.7 | 0.150976E+10 | 1888.28 | 8.17 | 7.45 | ||
Maximum of Months | 0.652397E+10 | 27900.59 | 23.00 | 16.21 | 0.227396E+10 | 2451.28 | 23.17 | 15.80 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.193719E+11 | 53908.96 | 10-JAN-07:05 | -4.3 | -5.5 | 0.699553E+10 | 8511.77 | 18-JAN-15:50 | 11.17 | 9.56 |
February | 0.189559E+11 | 52292.44 | 17-FEB-07:05 | -3.8 | -3.8 | 0.636420E+10 | 8230.38 | 04-FEB-15:09 | 8.67 | 6.40 |
March | 0.232462E+11 | 38317.03 | 13-MAR-07:03 | 1.33 | 0.36 | 0.735095E+10 | 9104.99 | 25-MAR-13:30 | 13.00 | 10.25 |
April | 0.294437E+11 | 130528.27 | 30-APR-08:62 | 17.50 | 12.50 | 0.792869E+10 | 10327.05 | 28-APR-14:00 | 20.10 | 13.68 |
May | 0.339718E+11 | 94184.51 | 26-MAY-06:03 | 8.17 | 8.07 | 0.853399E+10 | 10327.12 | 31-MAY-14:00 | 19.00 | 14.76 |
June | 0.367603E+11 | 143518.34 | 16-JUN-06:03 | 12.00 | 10.44 | 0.914604E+10 | 10327.45 | 09-JUN-14:09 | 18.33 | 13.87 |
July | 0.398246E+11 | 140386.39 | 20-JUL-06:03 | 11.00 | 11.00 | 0.916934E+10 | 10327.24 | 18-JUL-14:00 | 18.00 | 15.44 |
August | 0.397476E+11 | 146340.41 | 25-AUG-06:03 | 12.50 | 10.09 | 0.958923E+10 | 10327.29 | 15-AUG-14:09 | 18.83 | 15.23 |
September | 0.339427E+11 | 141583.72 | 15-SEP-06:03 | 10.33 | 10.25 | 0.896817E+10 | 10327.13 | 23-SEP-10:09 | 18.00 | 14.38 |
October | 0.278906E+11 | 39427.80 | 06-OCT-06:03 | 3.00 | 3.00 | 0.787454E+10 | 10326.90 | 07-OCT-11:20 | 15.33 | 10.35 |
November | 0.221902E+11 | 43439.77 | 29-NOV-07:05 | -1.0 | -1.5 | 0.681931E+10 | 9074.29 | 10-NOV-15:39 | 11.33 | 8.40 |
December | 0.179146E+11 | 48193.28 | 27-DEC-07:05 | -1.8 | -1.9 | 0.697216E+10 | 8043.33 | 23-DEC-14:30 | 10.00 | 7.08 |
Annual Sum or Average | 0.343260E+12 | 0.957121E+11 | ||||||||
Minimum of Months | 0.179146E+11 | 38317.03 | -4.3 | -5.5 | 0.636420E+10 | 8043.33 | 8.67 | 6.40 | ||
Maximum of Months | 0.398246E+11 | 146340.41 | 17.50 | 12.50 | 0.958923E+10 | 10327.45 | 20.10 | 15.44 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.323420E+10 | 4788.48 | 11-JAN-14:00 | -2.0 | -3.4 | 0.719029E+09 | 973.08 | 17-JAN-15:00 | 9.00 | 7.94 |
February | 0.311984E+10 | 4961.11 | 04-FEB-14:20 | 9.00 | 6.27 | 0.667232E+09 | 973.07 | 04-FEB-12:20 | 8.33 | 5.53 |
March | 0.311789E+10 | 4304.07 | 08-MAR-07:05 | -0.5 | -1.1 | 0.761414E+09 | 973.09 | 25-MAR-13:20 | 13.33 | 10.57 |
April | 0.503866E+10 | 18128.50 | 30-APR-08:62 | 17.50 | 12.50 | 0.822954E+09 | 973.12 | 14-APR-14:20 | 12.67 | 8.30 |
May | 0.486351E+10 | 7118.41 | 23-MAY-13:20 | 18.33 | 14.51 | 0.860156E+09 | 973.14 | 31-MAY-14:00 | 19.00 | 14.76 |
June | 0.594152E+10 | 21827.98 | 14-JUN-06:02 | 12.00 | 12.00 | 0.870201E+09 | 973.18 | 09-JUN-14:09 | 18.33 | 13.87 |
July | 0.686420E+10 | 21738.63 | 13-JUL-06:02 | 13.00 | 12.44 | 0.866831E+09 | 973.17 | 18-JUL-14:00 | 18.00 | 15.44 |
August | 0.784103E+10 | 22439.03 | 19-AUG-06:02 | 12.00 | 11.46 | 0.905224E+09 | 973.16 | 26-AUG-14:09 | 17.83 | 14.80 |
September | 0.752442E+10 | 23772.76 | 12-SEP-06:02 | 11.33 | 10.19 | 0.853174E+09 | 973.18 | 13-SEP-14:20 | 23.00 | 16.21 |
October | 0.467149E+10 | 8868.23 | 07-OCT-13:40 | 17.00 | 9.63 | 0.822518E+09 | 973.10 | 14-OCT-10:50 | 12.83 | 9.72 |
November | 0.323238E+10 | 4509.89 | 03-NOV-14:30 | 9.00 | 5.71 | 0.724876E+09 | 973.09 | 25-NOV-12:20 | 10.00 | 5.89 |
December | 0.267590E+10 | 4538.30 | 27-DEC-07:05 | -1.8 | -1.9 | 0.687979E+09 | 972.78 | 18-DEC-15:09 | 7.60 | 5.42 |
Annual Sum or Average | 0.581250E+11 | 0.956159E+10 | ||||||||
Minimum of Months | 0.267590E+10 | 4304.07 | -2.0 | -3.4 | 0.667232E+09 | 972.78 | 7.60 | 5.42 | ||
Maximum of Months | 0.784103E+10 | 23772.76 | 18.33 | 14.51 | 0.905224E+09 | 973.18 | 23.00 | 16.21 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.137635E+10 | 4433.18 | 10-JAN-06:04 | -4.0 | -4.8 | 0.679220E+09 | 932.39 | 19-JAN-15:39 | 8.33 | 7.46 |
February | 0.148073E+10 | 4317.12 | 17-FEB-06:04 | -3.1 | -3.1 | 0.621874E+09 | 973.09 | 04-FEB-15:09 | 8.67 | 6.40 |
March | 0.134622E+10 | 3744.39 | 08-MAR-07:05 | -0.5 | -1.1 | 0.703115E+09 | 939.79 | 25-MAR-13:30 | 13.00 | 10.25 |
April | 0.293237E+10 | 6422.27 | 29-APR-13:40 | 19.67 | 12.48 | 0.785026E+09 | 973.11 | 14-APR-14:09 | 12.83 | 8.37 |
May | 0.277392E+10 | 4813.86 | 23-MAY-14:10 | 18.83 | 14.70 | 0.813442E+09 | 973.12 | 31-MAY-14:00 | 19.00 | 14.76 |
June | 0.335646E+10 | 5341.30 | 13-JUN-15:00 | 26.00 | 17.81 | 0.857788E+09 | 973.13 | 23-JUN-14:09 | 15.00 | 13.80 |
July | 0.411402E+10 | 13591.31 | 23-JUL-08:62 | 19.17 | 15.33 | 0.861802E+09 | 973.12 | 28-JUL-14:09 | 17.00 | 14.52 |
August | 0.495259E+10 | 6648.70 | 30-AUG-13:00 | 21.00 | 15.44 | 0.902536E+09 | 973.14 | 11-AUG-14:00 | 17.00 | 15.73 |
September | 0.487828E+10 | 7676.50 | 12-SEP-14:10 | 21.17 | 16.36 | 0.846763E+09 | 973.14 | 19-SEP-14:09 | 13.83 | 13.83 |
October | 0.270952E+10 | 6486.16 | 07-OCT-13:40 | 17.00 | 9.63 | 0.769521E+09 | 973.11 | 10-OCT-14:09 | 13.00 | 11.87 |
November | 0.153164E+10 | 3843.55 | 29-NOV-07:05 | -1.0 | -1.5 | 0.664665E+09 | 973.09 | 15-NOV-15:09 | 11.67 | 8.74 |
December | 0.859484E+09 | 3981.89 | 27-DEC-07:05 | -1.8 | -1.9 | 0.663037E+09 | 890.78 | 18-DEC-15:09 | 7.60 | 5.42 |
Annual Sum or Average | 0.323116E+11 | 0.916879E+10 | ||||||||
Minimum of Months | 0.859484E+09 | 3744.39 | -4.0 | -4.8 | 0.621874E+09 | 890.78 | 7.60 | 5.42 | ||
Maximum of Months | 0.495259E+10 | 13591.31 | 26.00 | 17.81 | 0.902536E+09 | 973.14 | 19.00 | 15.73 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 | 1.45 | 0.00 | 0.00 | 01-JAN-00:10 | 1.92 | 1.45 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 | 5.79 | 0.00 | 0.00 | 01-FEB-00:10 | 7.00 | 5.79 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 | 3.71 | 0.00 | 0.00 | 01-MAR-00:10 | 3.80 | 3.71 |
April | 0.00 | 0.00 | 01-APR-00:10 | 4.23 | 1.83 | 0.00 | 0.00 | 01-APR-00:10 | 4.23 | 1.83 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 | 8.15 | 0.00 | 0.00 | 01-MAY-00:10 | 10.47 | 8.15 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 | 7.38 | 0.00 | 0.00 | 01-JUN-00:10 | 9.27 | 7.38 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 | 9.95 | 0.00 | 0.00 | 01-JUL-00:10 | 11.00 | 9.95 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 | 9.82 | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 | 9.82 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 | 10.95 | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 | 10.95 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 | 5.82 | 0.00 | 0.00 | 01-OCT-00:10 | 7.57 | 5.82 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 | 4.28 | 0.00 | 0.00 | 01-NOV-00:10 | 6.57 | 4.28 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 | 0.00 | 0.00 | 01-DEC-00:10 | 4.00 | 3.53 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 1.92 | 1.45 | 0.00 | 0.00 | 1.92 | 1.45 | ||
Maximum of Months | 0.00 | 0.00 | 12.43 | 10.95 | 0.00 | 0.00 | 12.43 | 10.95 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.239895E+10 | 42265.02 | 01-JAN-08:61 | 4.83 |
February | 0.199570E+10 | 42230.94 | 20-FEB-08:61 | 1.33 |
March | 0.132794E+10 | 41902.36 | 04-MAR-06:02 | 3.00 |
April | 0.275553E+09 | 37786.04 | 02-APR-08:62 | 7.33 |
May | 0.112782E+09 | 25073.95 | 06-MAY-06:03 | 3.50 |
June | 65376394.55 | 675.33 | 11-JUN-07:55 | 14.00 |
July | 66934536.68 | 671.66 | 30-JUL-07:43 | 14.67 |
August | 68935844.83 | 670.57 | 27-AUG-07:23 | 15.00 |
September | 67129878.46 | 671.42 | 28-SEP-06:00 | 7.00 |
October | 0.258010E+09 | 37016.76 | 23-OCT-06:03 | 4.00 |
November | 0.117247E+10 | 41939.42 | 29-NOV-06:02 | -1.0 |
December | 0.258847E+10 | 42251.97 | 30-DEC-06:01 | -1.0 |
Annual Sum or Average | 0.103982E+11 | |||
Minimum of Months | 65376394.55 | 670.57 | -1.0 | |
Maximum of Months | 0.258847E+10 | 42265.02 | 15.00 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.156335E+10 | 209354.10 | 01-JAN-08:61 | 4.83 |
February | 0.106366E+10 | 136568.93 | 20-FEB-09:02 | 3.33 |
March | 0.823681E+09 | 101325.50 | 06-MAR-07:03 | 4.33 |
April | 0.521349E+09 | 19934.47 | 08-APR-06:08 | 0.33 |
May | 0.497197E+09 | 4836.67 | 06-MAY-05:23 | 2.50 |
June | 0.475816E+09 | 4841.55 | 11-JUN-07:55 | 14.00 |
July | 0.477035E+09 | 4823.37 | 30-JUL-07:43 | 14.67 |
August | 0.498040E+09 | 4804.52 | 27-AUG-07:23 | 15.00 |
September | 0.483435E+09 | 4766.87 | 10-SEP-07:25 | 14.00 |
October | 0.533304E+09 | 13525.98 | 28-OCT-06:10 | 6.50 |
November | 0.779017E+09 | 109729.69 | 20-NOV-07:03 | 1.00 |
December | 0.168315E+10 | 205766.65 | 26-DEC-06:01 | 1.92 |
Annual Sum or Average | 0.939903E+10 | |||
Minimum of Months | 0.475816E+09 | 4766.87 | 0.33 | |
Maximum of Months | 0.168315E+10 | 209354.10 | 15.00 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.322809E+09 | 32126.58 | 01-JAN-08:61 | 4.83 |
February | 0.226967E+09 | 31920.26 | 17-FEB-06:01 | -3.1 |
March | 0.226540E+09 | 26247.54 | 06-MAR-06:02 | 4.00 |
April | 56186026.04 | 4787.98 | 11-APR-06:03 | 5.33 |
May | 50839145.77 | 542.69 | 28-MAY-08:00 | 9.00 |
June | 48524924.61 | 520.16 | 11-JUN-07:55 | 14.00 |
July | 47870111.70 | 516.43 | 30-JUL-07:43 | 14.67 |
August | 51281049.33 | 516.63 | 06-AUG-07:23 | 13.50 |
September | 50652788.85 | 526.84 | 28-SEP-06:00 | 7.00 |
October | 55491180.58 | 2169.54 | 28-OCT-06:03 | 6.50 |
November | 0.140614E+09 | 22584.03 | 27-NOV-06:02 | 4.00 |
December | 0.513622E+09 | 32118.29 | 30-DEC-06:01 | -1.0 |
Annual Sum or Average | 0.179140E+10 | |||
Minimum of Months | 47870111.70 | 516.43 | -3.1 | |
Maximum of Months | 0.513622E+09 | 32126.58 | 14.67 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.842535E+09 | 24409.21 | 01-JAN-08:61 | 4.83 |
February | 0.663925E+09 | 24338.78 | 27-FEB-06:02 | 6.00 |
March | 0.711310E+09 | 23976.30 | 06-MAR-06:02 | 4.00 |
April | 0.105930E+09 | 15441.38 | 11-APR-06:03 | 5.33 |
May | 69491666.76 | 14937.58 | 06-MAY-06:03 | 3.50 |
June | 3534799.47 | 9697.15 | 08-JUN-06:03 | 7.50 |
July | 1174396.01 | 5066.70 | 05-JUL-06:03 | 9.50 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 11.43 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 12.43 |
October | 0.132766E+09 | 15080.42 | 23-OCT-06:03 | 4.00 |
November | 0.460151E+09 | 24206.69 | 25-NOV-06:02 | 7.00 |
December | 0.124988E+10 | 24223.17 | 03-DEC-08:61 | 4.00 |
Annual Sum or Average | 0.424069E+10 | |||
Minimum of Months | 0.00 | 0.00 | 3.50 | |
Maximum of Months | 0.124988E+10 | 24409.21 | 12.43 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.137679E+11 | 30681.06 | 11-JAN-18:00 | -4.0 |
February | 0.117503E+11 | 23106.51 | 16-FEB-18:00 | 2.00 |
March | 0.118055E+11 | 24315.02 | 15-MAR-12:00 | 1.00 |
April | 0.720148E+10 | 16654.46 | 10-APR-11:10 | 7.00 |
May | 0.725355E+10 | 15218.40 | 04-MAY-17:00 | 8.00 |
June | 0.416291E+10 | 13605.41 | 07-JUN-11:10 | 9.50 |
July | 0.259148E+10 | 10060.55 | 04-JUL-14:00 | 12.00 |
August | 0.140209E+10 | 5312.07 | 11-AUG-17:00 | 16.00 |
September | 0.293485E+10 | 11562.13 | 08-SEP-11:07 | 11.33 |
October | 0.768646E+10 | 15149.90 | 27-OCT-17:00 | 8.00 |
November | 0.112235E+11 | 24678.54 | 28-NOV-18:00 | 1.00 |
December | 0.141029E+11 | 28308.30 | 29-DEC-18:00 | -2.0 |
Annual Sum or Average | 0.958829E+11 | |||
Minimum of Months | 0.140209E+10 | 5312.07 | -4.0 | |
Maximum of Months | 0.141029E+11 | 30681.06 | 16.00 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.244735E+10 | 2030.36 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.222649E+10 | 2030.36 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.253900E+10 | 2030.36 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.239592E+10 | 2030.36 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.249318E+10 | 2030.36 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.245011E+10 | 2030.36 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.243899E+10 | 2030.36 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.253900E+10 | 2030.36 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.239592E+10 | 2030.36 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.244735E+10 | 2030.36 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.236682E+10 | 2030.36 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.243899E+10 | 2030.36 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.291791E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.222649E+10 | 2030.36 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.253900E+10 | 2030.36 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.254534E+11 | 22187.24 | 02-JAN-09:09 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.220831E+11 | 22187.24 | 01-FEB-09:09 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.231607E+11 | 22187.24 | 01-MAR-09:09 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.184377E+11 | 22187.24 | 10-APR-08:09 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.189001E+11 | 20338.30 | 01-MAY-16:30 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.182039E+11 | 20338.30 | 02-JUN-16:49 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.182990E+11 | 20338.30 | 07-JUL-15:50 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.197802E+11 | 22187.24 | 08-AUG-08:09 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.210308E+11 | 22187.24 | 02-SEP-15:50 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.236951E+11 | 22187.24 | 02-OCT-16:40 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.244763E+11 | 22187.24 | 01-NOV-08:09 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.258910E+11 | 22187.24 | 01-DEC-09:09 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.259411E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.182039E+11 | 20338.30 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.258910E+11 | 22187.24 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.249582E+10 | 2090.65 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.227087E+10 | 2090.65 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.259032E+10 | 2090.65 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.244398E+10 | 2090.65 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.254307E+10 | 2090.65 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.249959E+10 | 2090.65 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.248746E+10 | 2090.65 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.259032E+10 | 2090.65 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.244398E+10 | 2090.65 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.249582E+10 | 2090.65 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.241345E+10 | 2090.65 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.248746E+10 | 2090.65 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.297621E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.227087E+10 | 2090.65 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.259032E+10 | 2090.65 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.249582E+10 | 2090.65 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.227087E+10 | 2090.65 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.259032E+10 | 2090.65 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.244398E+10 | 2090.65 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.254307E+10 | 2090.65 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.249959E+10 | 2090.65 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.248746E+10 | 2090.65 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.259032E+10 | 2090.65 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.244398E+10 | 2090.65 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.249582E+10 | 2090.65 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.241345E+10 | 2090.65 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.248746E+10 | 2090.65 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.297621E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.227087E+10 | 2090.65 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.259032E+10 | 2090.65 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.112411E+09 | 94.16 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.102280E+09 | 94.16 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.116668E+09 | 94.16 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.110076E+09 | 94.16 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.114539E+09 | 94.16 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.112581E+09 | 94.16 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.112035E+09 | 94.16 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.116668E+09 | 94.16 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.110076E+09 | 94.16 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.112411E+09 | 94.16 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.108701E+09 | 94.16 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.112035E+09 | 94.16 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.134048E+10 | ||||
Minimum of Months | 0.102280E+09 | 94.16 | 0.00 | 0.00 | |
Maximum of Months | 0.116668E+09 | 94.16 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.244735E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.462300E+09 |
February | 0.479114E+10 | 0.222649E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.689238E+09 |
March | 0.548013E+10 | 0.253900E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411504E+09 |
April | 0.518069E+10 | 0.239592E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6289.60 | 0.472416E+09 |
May | 0.536353E+10 | 0.249318E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 780.91 | 0.129768E+10 |
June | 0.528933E+10 | 0.245011E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 787340.17 | 0.105998E+10 |
July | 0.525489E+10 | 0.243899E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2956677.69 | 0.979824E+09 |
August | 0.548013E+10 | 0.253900E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 495350.50 | 0.749843E+09 |
September | 0.518069E+10 | 0.239592E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.771845E+09 |
October | 0.524694E+10 | 0.244735E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.752698E+09 |
November | 0.504819E+10 | 0.236682E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.918262E+09 |
December | 0.525489E+10 | 0.243899E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.123647E+10 |
Annual Sum or Average | 0.628175E+11 | 0.291791E+11 | 0.499918E+11 | 4246438.87 | 0.980207E+10 | ||||
Minimum of Months | 0.479114E+10 | 0.222649E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.411504E+09 |
Maximum of Months | 0.548013E+10 | 0.253900E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2956677.69 | 0.129768E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.254534E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.403396E+09 |
February | 0.201852E+11 | 0.220831E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.606570E+09 |
March | 0.230879E+11 | 0.231607E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356599E+09 |
April | 0.218263E+11 | 0.184377E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4806.65 | 0.411724E+09 |
May | 0.225967E+11 | 0.189001E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 641.83 | 0.115449E+10 |
June | 0.222841E+11 | 0.182039E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 644619.72 | 0.938489E+09 |
July | 0.221389E+11 | 0.182990E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2420393.85 | 0.870098E+09 |
August | 0.230879E+11 | 0.197802E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 405611.68 | 0.665178E+09 |
September | 0.218263E+11 | 0.210308E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.684894E+09 |
October | 0.221054E+11 | 0.236951E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.666455E+09 |
November | 0.212681E+11 | 0.244763E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.815051E+09 |
December | 0.221389E+11 | 0.258910E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109455E+10 |
Annual Sum or Average | 0.264651E+12 | 0.259411E+12 | 0.842987E+11 | 3476073.73 | 0.866750E+10 | ||||
Minimum of Months | 0.201852E+11 | 0.182039E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356599E+09 |
Maximum of Months | 0.230879E+11 | 0.258910E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2420393.85 | 0.115449E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.249582E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211701E+09 |
February | 0.190200E+10 | 0.227087E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.319389E+09 |
March | 0.217552E+10 | 0.259032E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189241E+09 |
April | 0.205665E+10 | 0.244398E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2544.64 | 0.226489E+09 |
May | 0.212923E+10 | 0.254307E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 340.27 | 0.609956E+09 |
June | 0.209978E+10 | 0.249959E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 341265.49 | 0.486037E+09 |
July | 0.208610E+10 | 0.248746E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1281246.36 | 0.451992E+09 |
August | 0.217552E+10 | 0.259032E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 214745.00 | 0.353582E+09 |
September | 0.205665E+10 | 0.244398E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.367372E+09 |
October | 0.208295E+10 | 0.249582E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362759E+09 |
November | 0.200405E+10 | 0.241345E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.430122E+09 |
December | 0.208610E+10 | 0.248746E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.552235E+09 |
Annual Sum or Average | 0.249375E+11 | 0.297621E+11 | 0.529224E+11 | 1840141.77 | 0.456087E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.227087E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.189241E+09 |
Maximum of Months | 0.217552E+10 | 0.259032E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1281246.36 | 0.609956E+09 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.249582E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202962E+09 |
February | 0.190200E+10 | 0.227087E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304540E+09 |
March | 0.217552E+10 | 0.259032E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178452E+09 |
April | 0.205665E+10 | 0.244398E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2546.03 | 0.214218E+09 |
May | 0.212923E+10 | 0.254307E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 339.16 | 0.571785E+09 |
June | 0.209978E+10 | 0.249959E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 341162.38 | 0.459477E+09 |
July | 0.208610E+10 | 0.248746E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1281167.92 | 0.427731E+09 |
August | 0.217552E+10 | 0.259032E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 214678.59 | 0.335197E+09 |
September | 0.205665E+10 | 0.244398E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.350186E+09 |
October | 0.208295E+10 | 0.249582E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339306E+09 |
November | 0.200405E+10 | 0.241345E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404684E+09 |
December | 0.208610E+10 | 0.248746E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531247E+09 |
Annual Sum or Average | 0.249375E+11 | 0.297621E+11 | 0.794328E+10 | 1839894.08 | 0.431979E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.227087E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.178452E+09 |
Maximum of Months | 0.217552E+10 | 0.259032E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 1281167.92 | 0.571785E+09 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.112411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137417E+11 |
February | 0.00 | 0.102280E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.118119E+11 |
March | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117150E+11 |
April | 0.00 | 0.110076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.771756E+10 |
May | 0.00 | 0.114539E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.775053E+10 |
June | 0.00 | 0.112581E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7544.33 | 0.476743E+10 |
July | 0.00 | 0.112035E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1843848.74 | 0.333584E+10 |
August | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 812.24 | 0.233389E+10 |
September | 0.00 | 0.110076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.389163E+10 |
October | 0.00 | 0.112411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.815706E+10 |
November | 0.00 | 0.108701E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113149E+11 |
December | 0.00 | 0.112035E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139162E+11 |
Annual Sum or Average | 0.00 | 0.134048E+10 | 1852205.31 | 0.100454E+12 | |||||
Minimum of Months | 0.00 | 0.102280E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.233389E+10 |
Maximum of Months | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1843848.74 | 0.139162E+11 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 2030.36 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1747.96 | 08-JAN-08:00 |
February | 5888.82 | 01-FEB-15:09 | 2030.36 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1736.45 | 01-FEB-21:03 |
March | 5888.82 | 01-MAR-15:09 | 2030.36 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1643.38 | 27-MAR-20:03 |
April | 5888.82 | 01-APR-10:09 | 2030.36 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.90 | 30-APR-18:03 | 1704.66 | 23-APR-22:00 |
May | 5888.82 | 01-MAY-14:09 | 2030.36 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.30 | 22-MAY-15:00 | 2657.79 | 04-MAY-23:00 |
June | 5888.82 | 01-JUN-14:09 | 2030.36 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 53.72 | 13-JUN-15:30 | 1922.80 | 05-JUN-21:00 |
July | 5888.82 | 01-JUL-10:09 | 2030.36 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 77.73 | 22-JUL-15:00 | 1759.06 | 30-JUL-19:00 |
August | 5888.82 | 01-AUG-14:09 | 2030.36 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 40.38 | 14-AUG-16:40 | 1437.77 | 22-AUG-21:00 |
September | 5888.82 | 01-SEP-14:09 | 2030.36 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1722.34 | 06-SEP-20:10 |
October | 5888.82 | 02-OCT-14:09 | 2030.36 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1959.26 | 20-OCT-22:00 |
November | 5888.82 | 01-NOV-14:09 | 2030.36 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1987.22 | 26-NOV-04:00 |
December | 5888.82 | 01-DEC-15:09 | 2030.36 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2801.57 | 05-DEC-22:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1437.77 | |||||
Maximum of Months | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 77.73 | 2801.57 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 22187.24 | 02-JAN-09:09 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1611.86 | 08-JAN-08:00 |
February | 24809.68 | 01-FEB-15:09 | 22187.24 | 01-FEB-09:09 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1521.63 | 08-FEB-22:00 |
March | 24809.68 | 01-MAR-15:09 | 22187.24 | 01-MAR-09:09 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1444.57 | 27-MAR-21:00 |
April | 24809.68 | 01-APR-10:09 | 22187.24 | 10-APR-08:09 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.62 | 30-APR-17:00 | 1582.57 | 23-APR-22:00 |
May | 24809.68 | 01-MAY-14:09 | 20338.30 | 01-MAY-16:30 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.07 | 22-MAY-15:00 | 2467.11 | 04-MAY-23:00 |
June | 24809.68 | 01-JUN-14:09 | 20338.30 | 02-JUN-16:49 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 43.98 | 13-JUN-15:30 | 1736.93 | 05-JUN-21:00 |
July | 24809.68 | 01-JUL-10:09 | 20338.30 | 07-JUL-15:50 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 63.63 | 22-JUL-15:00 | 1612.47 | 30-JUL-19:00 |
August | 24809.68 | 01-AUG-14:09 | 22187.24 | 08-AUG-08:09 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 33.06 | 14-AUG-16:40 | 1326.38 | 22-AUG-21:00 |
September | 24809.68 | 01-SEP-14:09 | 22187.24 | 02-SEP-15:50 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1559.27 | 06-SEP-04:00 |
October | 24809.68 | 02-OCT-14:09 | 22187.24 | 02-OCT-16:40 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 1825.38 | 20-OCT-22:00 |
November | 24809.68 | 01-NOV-14:09 | 22187.24 | 01-NOV-08:09 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1831.15 | 26-NOV-04:00 |
December | 24809.68 | 01-DEC-15:09 | 22187.24 | 01-DEC-09:09 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2546.52 | 05-DEC-22:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 20338.30 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1326.38 | |||||
Maximum of Months | 24809.68 | 22187.24 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 63.63 | 2546.52 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2090.65 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 814.09 | 08-JAN-08:00 |
February | 2337.76 | 01-FEB-15:09 | 2090.65 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 780.55 | 08-FEB-22:00 |
March | 2337.76 | 01-MAR-15:09 | 2090.65 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 726.64 | 27-MAR-21:00 |
April | 2337.76 | 01-APR-10:09 | 2090.65 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 30-APR-17:00 | 793.17 | 23-APR-22:00 |
May | 2337.76 | 01-MAY-14:09 | 2090.65 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 | 22-MAY-15:00 | 1217.40 | 04-MAY-23:00 |
June | 2337.76 | 01-JUN-14:09 | 2090.65 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23.28 | 13-JUN-15:30 | 889.73 | 05-JUN-21:00 |
July | 2337.76 | 01-JUL-10:09 | 2090.65 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 33.68 | 22-JUL-15:00 | 848.36 | 30-JUL-19:00 |
August | 2337.76 | 01-AUG-14:09 | 2090.65 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 17.50 | 14-AUG-16:40 | 699.02 | 22-AUG-21:00 |
September | 2337.76 | 01-SEP-14:09 | 2090.65 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 808.92 | 06-SEP-20:10 |
October | 2337.76 | 02-OCT-14:09 | 2090.65 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 952.23 | 01-OCT-24:00 |
November | 2337.76 | 01-NOV-14:09 | 2090.65 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 928.68 | 26-NOV-04:00 |
December | 2337.76 | 01-DEC-15:09 | 2090.65 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1254.23 | 05-DEC-22:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 699.02 | |||||
Maximum of Months | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 33.68 | 1254.23 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2090.65 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 776.81 | 08-JAN-08:00 |
February | 2337.76 | 01-FEB-15:09 | 2090.65 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 751.03 | 01-FEB-21:03 |
March | 2337.76 | 01-MAR-15:09 | 2090.65 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 711.30 | 27-MAR-20:03 |
April | 2337.76 | 01-APR-10:09 | 2090.65 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 30-APR-17:00 | 742.88 | 23-APR-22:00 |
May | 2337.76 | 01-MAY-14:09 | 2090.65 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 | 22-MAY-15:00 | 1118.90 | 04-MAY-23:00 |
June | 2337.76 | 01-JUN-14:09 | 2090.65 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 23.28 | 13-JUN-15:30 | 827.54 | 05-JUN-21:00 |
July | 2337.76 | 01-JUL-10:09 | 2090.65 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 33.68 | 22-JUL-15:00 | 810.36 | 30-JUL-19:00 |
August | 2337.76 | 01-AUG-14:09 | 2090.65 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 17.50 | 14-AUG-16:40 | 655.61 | 22-AUG-21:00 |
September | 2337.76 | 01-SEP-14:09 | 2090.65 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 772.21 | 06-SEP-20:10 |
October | 2337.76 | 02-OCT-14:09 | 2090.65 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 911.33 | 01-OCT-24:00 |
November | 2337.76 | 01-NOV-14:09 | 2090.65 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 879.28 | 26-NOV-04:00 |
December | 2337.76 | 01-DEC-15:09 | 2090.65 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1193.77 | 05-DEC-22:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 655.61 | |||||
Maximum of Months | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 33.68 | 1193.77 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 94.16 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 30652.25 | 11-JAN-18:00 |
February | 0.00 | 01-FEB-00:10 | 94.16 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 23078.04 | 16-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 94.16 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 24179.36 | 15-MAR-12:00 |
April | 0.00 | 01-APR-00:10 | 94.16 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 16620.84 | 10-APR-11:10 |
May | 0.00 | 01-MAY-00:10 | 94.16 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 15627.95 | 01-MAY-16:00 |
June | 0.00 | 01-JUN-00:10 | 94.16 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.61 | 12-JUN-18:00 | 13878.84 | 07-JUN-11:10 |
July | 0.00 | 01-JUL-00:10 | 94.16 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.42 | 21-JUL-17:00 | 10800.42 | 04-JUL-11:02 |
August | 0.00 | 01-AUG-00:10 | 94.16 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1.35 | 14-AUG-18:00 | 5887.75 | 11-AUG-17:00 |
September | 0.00 | 01-SEP-00:10 | 94.16 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 12203.14 | 08-SEP-11:03 |
October | 0.00 | 01-OCT-00:10 | 94.16 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 15144.06 | 27-OCT-17:00 |
November | 0.00 | 01-NOV-00:10 | 94.16 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 24631.99 | 28-NOV-18:00 |
December | 0.00 | 01-DEC-00:10 | 94.16 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 28159.11 | 29-DEC-18:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 94.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5887.75 | ||||
Maximum of Months | 0.00 | 94.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.42 | 30652.25 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5244.80 | 31-JAN-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 5892.42 | 24-FEB-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.45 |
March | 5627.44 | 08-MAR-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 5633.11 | 29-APR-15:30 | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.55 |
May | 5985.36 | 23-MAY-15:00 | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.44 |
June | 22801.33 | 27-JUN-06:02 | 4416.61 | 2707.14 | 7357.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.68 |
July | 27900.59 | 24-JUL-06:02 | 4416.61 | 2707.14 | 7357.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 174.72 |
August | 13045.01 | 15-AUG-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 74.57 |
September | 6827.72 | 13-SEP-15:00 | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.28 |
October | 4587.35 | 23-OCT-06:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 158.48 |
November | 5242.21 | 17-NOV-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 195.02 |
December | 5218.13 | 08-DEC-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 194.65 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4587.35 | 2944.41 | 1804.76 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 27900.59 | 5888.82 | 2707.14 | 7357.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 199.45 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 53908.96 | 10-JAN-07:05 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 201.58 |
February | 52292.44 | 17-FEB-07:05 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 38317.03 | 13-MAR-07:03 | 18607.26 | 29582.98 | 9305.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 130528.27 | 30-APR-08:62 | 12404.84 | 6574.00 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.76 |
May | 94184.51 | 26-MAY-06:03 | 9303.63 | 13558.87 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 246.11 |
June | 143518.34 | 16-JUN-06:03 | 12404.84 | 18078.49 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 164.34 |
July | 140386.39 | 20-JUL-06:03 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 149.21 |
August | 146340.41 | 25-AUG-06:03 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 141583.72 | 15-SEP-06:03 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.71 |
October | 39427.80 | 06-OCT-06:03 | 9303.63 | 14791.49 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.36 |
November | 43439.77 | 29-NOV-07:05 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 269.07 |
December | 48193.28 | 27-DEC-07:05 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 261.34 |
Annual Sum or Average | |||||||||||
Minimum of Months | 38317.03 | 9303.63 | 6574.00 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 146340.41 | 18607.26 | 29582.98 | 9305.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 269.07 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4788.48 | 11-JAN-14:00 | 2045.54 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 88.07 |
February | 4961.11 | 04-FEB-14:20 | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 77.30 |
March | 4304.07 | 08-MAR-07:05 | 1168.88 | 1858.36 | 5192.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 18128.50 | 30-APR-08:62 | 1168.88 | 929.18 | 3894.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.90 |
May | 7118.41 | 23-MAY-13:20 | 2045.54 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.03 |
June | 21827.98 | 14-JUN-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.18 |
July | 21738.63 | 13-JUL-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 94.08 |
August | 22439.03 | 19-AUG-06:02 | 1461.10 | 1161.47 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11.78 |
September | 23772.76 | 12-SEP-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 8868.23 | 07-OCT-13:40 | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.99 |
November | 4509.89 | 03-NOV-14:30 | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.39 |
December | 4538.30 | 27-DEC-07:05 | 1168.88 | 1858.36 | 5192.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.19 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4304.07 | 1168.88 | 929.18 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23772.76 | 2337.76 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.19 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4433.18 | 10-JAN-06:04 | 0.00 | 929.18 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.56 |
February | 4317.12 | 17-FEB-06:04 | 0.00 | 813.03 | 681.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.55 |
March | 3744.39 | 08-MAR-07:05 | 1168.88 | 1858.36 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6422.27 | 29-APR-13:40 | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.18 |
May | 4813.86 | 23-MAY-14:10 | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.11 |
June | 5341.30 | 13-JUN-15:00 | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 23.08 | 0.00 |
July | 13591.31 | 23-JUL-08:62 | 1461.10 | 1161.47 | 730.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.40 |
August | 6648.70 | 30-AUG-13:00 | 2045.54 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.03 |
September | 7676.50 | 12-SEP-14:10 | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.59 |
October | 6486.16 | 07-OCT-13:40 | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.99 |
November | 3843.55 | 29-NOV-07:05 | 1168.88 | 1858.36 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 142.93 |
December | 3981.89 | 27-DEC-07:05 | 1168.88 | 1858.36 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 137.92 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3744.39 | 0.00 | 813.03 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13591.31 | 2337.76 | 2090.65 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 23.08 | 168.56 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.49 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.22 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 01-APR-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.20 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.29 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.45 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.10 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.79 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.24 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.26 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.87 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.73 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.10 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.713907E+11 | 54170.79 | 11-JAN-17:00 | 0.727624E+11 | 161876.67 | 10-JAN-07:10 |
February | 0.629799E+11 | 53477.87 | 16-FEB-17:00 | 0.593300E+11 | 142072.99 | 17-FEB-07:10 |
March | 0.679949E+11 | 53182.38 | 03-MAR-17:00 | 0.518800E+11 | 113054.31 | 08-MAR-07:10 |
April | 0.603486E+11 | 52160.68 | 29-APR-14:00 | 0.210220E+11 | 74881.78 | 01-APR-06:10 |
May | 0.615334E+11 | 56825.97 | 22-MAY-14:00 | 0.163196E+11 | 42875.77 | 06-MAY-06:30 |
June | 0.620038E+11 | 63756.61 | 13-JUN-16:40 | 0.110979E+11 | 19467.89 | 07-JUN-11:09 |
July | 0.656060E+11 | 66304.31 | 21-JUL-16:00 | 0.959258E+10 | 15073.17 | 04-JUL-13:00 |
August | 0.692774E+11 | 62925.24 | 14-AUG-16:00 | 0.854907E+10 | 9283.12 | 11-AUG-13:00 |
September | 0.658470E+11 | 61793.07 | 13-SEP-15:00 | 0.983805E+10 | 15522.37 | 08-SEP-11:09 |
October | 0.675813E+11 | 52706.63 | 28-OCT-16:00 | 0.218121E+11 | 68098.39 | 23-OCT-06:10 |
November | 0.680904E+11 | 53613.97 | 28-NOV-17:00 | 0.463537E+11 | 122343.29 | 29-NOV-07:10 |
December | 0.721298E+11 | 53998.89 | 29-DEC-17:00 | 0.773925E+11 | 143085.61 | 30-DEC-07:10 |
Annual Sum or Average | 0.794783E+12 | 0.405950E+12 | ||||
Minimum of Months | 0.603486E+11 | 52160.68 | 0.854907E+10 | 9283.12 | ||
Maximum of Months | 0.721298E+11 | 66304.31 | 0.773925E+11 | 161876.67 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.330049E+11 | 0.679833E+10 | 0.164409E+11 | 0.00 | 0.151466E+11 | 0.00 | 0.00 | 1793.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.289536E+11 | 0.551164E+10 | 0.149157E+11 | 0.00 | 0.135982E+11 | 0.00 | 0.00 | 717203.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.309970E+11 | 0.523948E+10 | 0.168545E+11 | 0.00 | 0.149038E+11 | 0.00 | 0.00 | 1131.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.258317E+11 | 0.419874E+10 | 0.160165E+11 | 0.00 | 0.134185E+11 | 0.00 | 0.00 | 0.883168E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.265939E+11 | 0.364109E+10 | 0.166477E+11 | 0.00 | 0.137500E+11 | 0.00 | 0.00 | 0.900611E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.257658E+11 | 0.317252E+10 | 0.162772E+11 | 0.00 | 0.129642E+11 | 0.00 | 0.00 | 0.382406E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.258250E+11 | 0.341475E+10 | 0.163871E+11 | 0.00 | 0.129210E+11 | 0.00 | 0.00 | 0.705824E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.276165E+11 | 0.400304E+10 | 0.168545E+11 | 0.00 | 0.127478E+11 | 0.00 | 0.00 | 0.805552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.284247E+11 | 0.469187E+10 | 0.160165E+11 | 0.00 | 0.125730E+11 | 0.00 | 0.00 | 0.414087E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.312465E+11 | 0.574358E+10 | 0.164409E+11 | 0.00 | 0.138806E+11 | 0.00 | 0.00 | 0.269703E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.317788E+11 | 0.634113E+10 | 0.159174E+11 | 0.00 | 0.140522E+11 | 0.00 | 0.00 | 891646.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.334170E+11 | 0.700928E+10 | 0.163871E+11 | 0.00 | 0.153165E+11 | 0.00 | 0.00 | 11.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.349455E+12 | 0.597654E+11 | 0.195156E+12 | 0.165272E+12 | 0.00 | 0.251338E+11 | |||||||
Minimum of Months | 0.257658E+11 | 0.317252E+10 | 0.149157E+11 | 0.00 | 0.125730E+11 | 0.00 | 0.00 | 11.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.334170E+11 | 0.700928E+10 | 0.168545E+11 | 0.00 | 0.153165E+11 | 0.00 | 0.00 | 0.805552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.644448E+11 | 0.00 | 0.831760E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.517780E+11 | 0.00 | 0.755199E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.434703E+11 | 0.00 | 0.840968E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.130034E+11 | 0.00 | 0.801860E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.810749E+10 | 0.00 | 0.821212E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.320532E+10 | 0.00 | 0.789256E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.157248E+10 | 0.00 | 0.802010E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.468247E+09 | 0.00 | 0.808082E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.203745E+10 | 0.00 | 0.780059E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.137131E+11 | 0.00 | 0.809903E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.384425E+11 | 0.00 | 0.791118E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.691244E+11 | 0.00 | 0.826808E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.309368E+12 | 0.965824E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.468247E+09 | 0.00 | 0.755199E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.691244E+11 | 0.00 | 0.840968E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 28493.07 | 02-JAN-09:09 | 4566.05 | 01-JAN-06:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 11990.59 | 10-JAN-07:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 28493.07 | 01-FEB-09:09 | 4566.05 | 01-FEB-06:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 11576.73 | 17-FEB-07:10 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 28493.07 | 01-MAR-09:09 | 4566.05 | 01-MAR-06:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 10845.84 | 08-MAR-07:30 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 28493.07 | 10-APR-08:09 | 4566.05 | 01-APR-05:10 | 10771.04 | 01-APR-09:09 | 0.00 | 10056.61 | 01-APR-07:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 26644.13 | 01-MAY-16:30 | 4566.05 | 01-MAY-19:19 | 10771.04 | 01-MAY-08:09 | 0.00 | 9476.53 | 06-MAY-07:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 26644.13 | 02-JUN-16:49 | 4566.05 | 01-JUN-19:00 | 10771.04 | 01-JUN-08:09 | 0.00 | 10354.48 | 11-JUN-08:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 26644.13 | 07-JUL-15:50 | 4566.05 | 01-JUL-20:19 | 10771.04 | 01-JUL-09:09 | 0.00 | 10480.65 | 30-JUL-08:09 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 28493.07 | 08-AUG-08:09 | 4566.05 | 01-AUG-19:49 | 10771.04 | 01-AUG-08:09 | 0.00 | 10245.98 | 13-AUG-08:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 28493.07 | 02-SEP-15:50 | 4566.05 | 01-SEP-05:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 9344.45 | 24-SEP-08:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 28493.07 | 02-OCT-16:40 | 4566.05 | 01-OCT-05:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 10012.68 | 23-OCT-07:10 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 28493.07 | 01-NOV-08:09 | 4566.05 | 01-NOV-05:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 11103.57 | 20-NOV-07:10 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 28493.07 | 01-DEC-09:09 | 4566.05 | 01-DEC-06:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 11885.65 | 31-DEC-09:09 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 26644.13 | 4566.05 | 10771.04 | 0.00 | 9344.45 | 0.00 | 0.00 | |||||
Maximum of Months | 28493.07 | 4566.05 | 10771.04 | 0.00 | 11990.59 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.58 | 17-JAN-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 122.99 | 04-FEB-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.12 | 30-MAR-13:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 13690.98 | 30-APR-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16013.16 | 22-MAY-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 22065.03 | 13-JUN-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 23978.02 | 22-JUL-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 19447.84 | 14-AUG-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 18366.03 | 13-SEP-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 5432.78 | 07-OCT-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 107.29 | 10-NOV-13:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.01 | 18-DEC-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 23978.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 54170.79 | 11-JAN-17:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 10340.63 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 53477.87 | 16-FEB-17:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 9647.72 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 53182.38 | 03-MAR-17:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 9352.22 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 52160.68 | 29-APR-14:00 | 22946.26 | 10771.04 | 0.00 | 0.00 | 7986.00 | 0.00 | 0.00 | 10457.39 | 0.00 |
May | 56825.97 | 22-MAY-14:00 | 22946.26 | 10771.04 | 0.00 | 0.00 | 7095.51 | 0.00 | 0.00 | 16013.16 | 0.00 |
June | 63756.61 | 13-JUN-16:40 | 24795.20 | 10771.04 | 0.00 | 0.00 | 7095.51 | 0.00 | 0.00 | 21094.86 | 0.00 |
July | 66304.31 | 21-JUL-16:00 | 26644.13 | 10771.04 | 0.00 | 0.00 | 7095.51 | 0.00 | 0.00 | 21793.63 | 0.00 |
August | 62925.24 | 14-AUG-16:00 | 26644.13 | 10771.04 | 0.00 | 0.00 | 7095.51 | 0.00 | 0.00 | 18414.56 | 0.00 |
September | 61793.07 | 13-SEP-15:00 | 26644.13 | 10771.04 | 0.00 | 0.00 | 7095.51 | 0.00 | 0.00 | 17282.38 | 0.00 |
October | 52706.63 | 28-OCT-16:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 8876.48 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 53613.97 | 28-NOV-17:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 9783.81 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 53998.89 | 29-DEC-17:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 10168.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 52160.68 | 22946.26 | 10771.04 | 0.00 | 0.00 | 7095.51 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 66304.31 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 10340.63 | 0.00 | 0.00 | 21793.63 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 157311.23 | 10-JAN-07:10 | 0.00 | 5102.30 | 30-JAN-12:09 | 0.00 |
February | 0.00 | 0.00 | 140210.99 | 17-FEB-07:10 | 0.00 | 5104.49 | 14-FEB-12:30 | 0.00 |
March | 0.00 | 0.00 | 108488.63 | 08-MAR-07:10 | 0.00 | 5102.79 | 02-MAR-12:09 | 0.00 |
April | 0.00 | 0.00 | 70269.62 | 01-APR-06:10 | 0.00 | 5089.24 | 03-APR-11:09 | 0.00 |
May | 0.00 | 0.00 | 38558.47 | 06-MAY-06:40 | 0.00 | 5068.48 | 01-MAY-11:09 | 0.00 |
June | 0.00 | 0.00 | 14427.18 | 07-JUN-11:09 | 0.00 | 5044.83 | 01-JUN-11:39 | 0.00 |
July | 0.00 | 0.00 | 10349.46 | 04-JUL-13:00 | 0.00 | 5024.86 | 03-JUL-11:00 | 0.00 |
August | 0.00 | 0.00 | 4413.89 | 11-AUG-16:00 | 0.00 | 5014.74 | 31-AUG-11:09 | 0.00 |
September | 0.00 | 0.00 | 10930.93 | 08-SEP-11:09 | 0.00 | 5024.79 | 29-SEP-11:39 | 0.00 |
October | 0.00 | 0.00 | 66236.39 | 23-OCT-06:10 | 0.00 | 5048.21 | 31-OCT-11:09 | 0.00 |
November | 0.00 | 0.00 | 120481.29 | 29-NOV-07:10 | 0.00 | 5071.23 | 30-NOV-12:39 | 0.00 |
December | 0.00 | 0.00 | 138709.47 | 27-DEC-07:10 | 0.00 | 5089.84 | 28-DEC-12:00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 4413.89 | 0.00 | 5014.74 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 157311.23 | 0.00 | 5104.49 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.33 | 19.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 19.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 19.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.83 | 19.85 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.14 | 212.50 | 21.11 | 212.50 | 21.11 |
February | 376.00 | 21.12 | 165.83 | 21.11 | 165.83 | 21.11 |
March | 422.00 | 21.20 | 127.00 | 21.11 | 127.00 | 21.11 |
April | 405.00 | 22.27 | 18.50 | 21.12 | 18.50 | 21.12 |
May | 385.17 | 22.53 | 1.50 | 21.15 | 1.50 | 21.15 |
June | 200.00 | 23.36 | 22.33 | 23.89 | 0.00 | 0.00 |
July | 140.17 | 23.50 | 66.00 | 23.89 | 0.00 | 0.00 |
August | 118.83 | 23.57 | 38.50 | 23.89 | 0.00 | 0.00 |
September | 269.17 | 23.41 | 2.67 | 23.89 | 0.00 | 0.00 |
October | 414.00 | 22.05 | 7.67 | 21.13 | 7.67 | 21.13 |
November | 399.00 | 21.25 | 98.33 | 21.11 | 98.33 | 21.11 |
December | 415.00 | 21.11 | 237.50 | 21.11 | 237.50 | 21.11 |
Annual Sum or Average | 3958.33 | 21.92 | 998.33 | 21.47 | 868.83 | 21.11 |
Minimum of Months | 118.83 | 21.11 | 1.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.57 | 237.50 | 23.89 | 237.50 | 21.15 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.14 | 54.00 | 21.11 | 54.00 | 21.11 |
February | 376.00 | 21.12 | 21.00 | 21.11 | 21.00 | 21.11 |
March | 422.00 | 21.18 | 11.33 | 21.11 | 11.33 | 21.11 |
April | 347.00 | 21.99 | 1.67 | 23.89 | 0.00 | 0.00 |
May | 318.33 | 22.31 | 39.00 | 23.89 | 0.00 | 0.00 |
June | 89.00 | 22.94 | 194.17 | 23.88 | 0.00 | 0.00 |
July | 50.83 | 23.09 | 258.00 | 23.89 | 0.00 | 0.00 |
August | 32.17 | 23.21 | 278.50 | 23.89 | 0.00 | 0.00 |
September | 104.00 | 22.89 | 139.67 | 23.89 | 0.00 | 0.00 |
October | 395.50 | 21.95 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 399.00 | 21.22 | 9.67 | 21.11 | 9.67 | 21.11 |
December | 415.00 | 21.11 | 48.33 | 21.11 | 48.33 | 21.11 |
Annual Sum or Average | 3362.83 | 21.59 | 1055.33 | 23.51 | 144.33 | 21.11 |
Minimum of Months | 32.17 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.21 | 278.50 | 23.89 | 54.00 | 21.11 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 402.33 | 21.67 | 65.83 | 21.11 | 65.83 | 21.11 |
February | 369.67 | 21.82 | 42.00 | 21.11 | 42.00 | 21.11 |
March | 422.00 | 21.86 | 48.00 | 21.11 | 48.00 | 21.11 |
April | 248.33 | 22.77 | 36.83 | 23.77 | 1.50 | 21.11 |
May | 233.50 | 22.93 | 50.50 | 23.89 | 0.00 | 0.00 |
June | 66.17 | 23.20 | 198.83 | 23.89 | 0.00 | 0.00 |
July | 40.17 | 23.33 | 272.17 | 23.89 | 0.00 | 0.00 |
August | 22.17 | 23.57 | 309.83 | 23.89 | 0.00 | 0.00 |
September | 51.83 | 23.13 | 247.83 | 23.89 | 0.00 | 0.00 |
October | 265.00 | 22.55 | 41.33 | 23.89 | 0.00 | 0.00 |
November | 382.50 | 22.04 | 19.50 | 21.11 | 19.50 | 21.11 |
December | 415.00 | 21.40 | 103.33 | 21.11 | 103.33 | 21.11 |
Annual Sum or Average | 2918.67 | 22.10 | 1436.00 | 23.35 | 280.17 | 21.11 |
Minimum of Months | 22.17 | 21.40 | 19.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.57 | 309.83 | 23.89 | 103.33 | 21.11 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.33 | 139.33 | 21.11 | 139.33 | 21.11 |
February | 374.33 | 21.34 | 84.67 | 21.11 | 84.67 | 21.11 |
March | 422.00 | 21.28 | 106.33 | 21.11 | 106.33 | 21.11 |
April | 305.83 | 22.30 | 41.67 | 22.95 | 14.17 | 21.13 |
May | 310.50 | 22.35 | 37.17 | 23.56 | 4.50 | 21.16 |
June | 134.50 | 22.84 | 118.33 | 23.89 | 0.17 | 21.25 |
July | 88.17 | 23.03 | 203.50 | 23.89 | 0.00 | 0.00 |
August | 64.00 | 23.21 | 251.00 | 23.89 | 0.00 | 0.00 |
September | 95.00 | 22.78 | 190.00 | 23.89 | 0.00 | 0.00 |
October | 329.67 | 21.98 | 39.17 | 23.30 | 8.33 | 21.13 |
November | 398.50 | 21.45 | 51.67 | 21.11 | 51.67 | 21.11 |
December | 415.00 | 21.17 | 197.33 | 21.11 | 197.33 | 21.11 |
Annual Sum or Average | 3351.50 | 21.75 | 1460.17 | 22.74 | 606.50 | 21.11 |
Minimum of Months | 64.00 | 21.17 | 37.17 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 422.00 | 23.21 | 251.00 | 23.89 | 197.33 | 21.25 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.12478 | 39.59217 | -0.5283 | 11.06807 |
February | 376.00000 | 21.10126 | 40.43726 | -0.5225 | 10.83185 |
March | 422.00000 | 21.18631 | 40.61320 | -0.4795 | 10.00024 |
April | 405.00000 | 22.26456 | 38.69870 | -0.1821 | 7.04874 |
May | 418.00000 | 22.63309 | 43.38816 | -1.1153 | 32.94753 |
June | 408.00000 | 23.62656 | 47.84275 | -0.6912 | 15.87650 |
July | 415.00000 | 23.75624 | 47.99351 | -0.6141 | 13.45871 |
August | 422.00000 | 23.79700 | 48.18500 | -0.6043 | 12.95624 |
September | 405.00000 | 23.56246 | 47.01590 | -0.7398 | 17.44172 |
October | 414.00000 | 22.04393 | 47.72370 | -0.1900 | 6.69860 |
November | 399.00000 | 21.23907 | 43.67248 | -0.4436 | 9.44103 |
December | 415.00000 | 21.09726 | 37.78877 | -0.5502 | 11.46087 |
Annual Sum or Average | 4913.00000 | 22.29548 | 43.60299 | -0.5563 | 13.31014 |
Minimum of Months | 376.00000 | 21.09726 | 37.78877 | -1.1153 | 6.69860 |
Maximum of Months | 422.00000 | 23.79700 | 48.18500 | -0.1821 | 32.94753 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.13493 | 35.24017 | -0.4247 | 8.98685 |
February | 376.00000 | 21.11302 | 36.51142 | -0.4096 | 8.60860 |
March | 422.00000 | 21.17887 | 36.14591 | -0.3817 | 8.20264 |
April | 405.00000 | 22.27314 | 34.94347 | -0.0747 | 6.49001 |
May | 418.00000 | 22.68902 | 40.40833 | -0.9346 | 25.47875 |
June | 408.00000 | 23.66087 | 46.23510 | -0.5350 | 11.65940 |
July | 415.00000 | 23.78685 | 46.83586 | -0.4702 | 10.07418 |
August | 422.00000 | 23.83304 | 47.03968 | -0.4597 | 9.65691 |
September | 405.00000 | 23.62175 | 45.26212 | -0.5763 | 12.74336 |
October | 414.00000 | 22.05156 | 44.08012 | -0.0915 | 6.11197 |
November | 399.00000 | 21.22366 | 40.17705 | -0.3464 | 7.75084 |
December | 415.00000 | 21.10435 | 34.32530 | -0.4467 | 9.27645 |
Annual Sum or Average | 4913.00000 | 22.31547 | 40.63131 | -0.4303 | 10.45069 |
Minimum of Months | 376.00000 | 21.10435 | 34.32530 | -0.9346 | 6.11197 |
Maximum of Months | 422.00000 | 23.83304 | 47.03968 | -0.0747 | 25.47875 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.71923 | 34.01434 | -0.3062 | 8.43004 |
February | 376.00000 | 21.84275 | 35.00620 | -0.2567 | 7.71004 |
March | 422.00000 | 21.85091 | 34.88219 | -0.2763 | 7.68073 |
April | 405.00000 | 23.19914 | 31.93910 | 0.13165 | 6.98227 |
May | 418.00000 | 23.34836 | 37.51511 | -0.7666 | 19.48459 |
June | 408.00000 | 23.78000 | 44.04188 | -0.5121 | 11.16837 |
July | 415.00000 | 23.84176 | 44.94963 | -0.4457 | 9.66875 |
August | 422.00000 | 23.87996 | 44.75977 | -0.3994 | 8.66275 |
September | 405.00000 | 23.79617 | 42.18672 | -0.4474 | 10.05083 |
October | 414.00000 | 23.03251 | 40.38415 | 0.12019 | 6.85944 |
November | 399.00000 | 22.11420 | 37.95896 | -0.1734 | 7.06590 |
December | 415.00000 | 21.38869 | 33.44110 | -0.4195 | 9.40366 |
Annual Sum or Average | 4913.00000 | 22.82265 | 38.45336 | -0.3143 | 9.45650 |
Minimum of Months | 376.00000 | 21.38869 | 31.93910 | -0.7666 | 6.85944 |
Maximum of Months | 422.00000 | 23.87996 | 44.94963 | 0.13165 | 19.48459 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.31418 | 34.49294 | -0.4354 | 9.77947 |
February | 376.00000 | 21.33358 | 35.63591 | -0.4053 | 9.13527 |
March | 422.00000 | 21.26456 | 35.47367 | -0.4412 | 9.50804 |
April | 405.00000 | 22.66698 | 34.06966 | -0.0103 | 7.19537 |
May | 418.00000 | 22.72092 | 39.84155 | -0.9966 | 28.75840 |
June | 408.00000 | 23.51902 | 46.01403 | -0.6414 | 15.16140 |
July | 415.00000 | 23.69042 | 46.63971 | -0.5419 | 12.19588 |
August | 422.00000 | 23.77174 | 46.50994 | -0.4808 | 10.54325 |
September | 405.00000 | 23.60716 | 44.09087 | -0.5504 | 13.02307 |
October | 414.00000 | 22.34768 | 42.86443 | -0.0531 | 7.11866 |
November | 399.00000 | 21.43858 | 39.11577 | -0.3544 | 8.43527 |
December | 415.00000 | 21.15380 | 33.55679 | -0.5153 | 10.88868 |
Annual Sum or Average | 4913.00000 | 22.41018 | 39.89281 | -0.4537 | 11.85293 |
Minimum of Months | 376.00000 | 21.15380 | 33.55679 | -0.9966 | 7.11866 |
Maximum of Months | 422.00000 | 23.77174 | 46.63971 | -0.0103 | 28.75840 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.146199E+09 | 39252572.01 | 36.04 | 0.141755E+09 | 4443565.97 | 0.00 | 0.45 | 30-APR-15:30 | 0.00 | 01-APR-00:10 | 4976.29 | 30-APR-15:30 | 4976.29 | 30-APR-15:30 | 326.55 | 28-APR-15:00 | 1318.75 | 30-APR-15:30 | 0.00 | 01-APR-00:10 |
May | 0.141797E+09 | 37637348.73 | 46.94 | 0.114754E+09 | 27042459.20 | 0.00 | 0.56 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 6685.50 | 22-MAY-15:00 | 5706.27 | 22-MAY-15:00 | 979.23 | 22-MAY-15:00 | 1702.79 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.122995E+10 | 0.308341E+09 | 169.55 | 0.982390E+09 | 0.247562E+09 | 0.00 | 0.87 | 13-JUN-15:00 | 0.00 | 01-JUN-00:10 | 25147.11 | 27-JUN-06:02 | 13528.96 | 27-JUN-06:02 | 11618.15 | 27-JUN-06:02 | 5351.73 | 27-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.235271E+10 | 0.598323E+09 | 237.65 | 0.188234E+10 | 0.470365E+09 | 0.00 | 1.00 | 22-JUL-06:02 | 0.00 | 01-JUL-00:10 | 27563.00 | 23-JUL-08:62 | 22617.80 | 22-JUL-06:02 | 11315.44 | 24-JUL-06:02 | 5866.98 | 23-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.224873E+10 | 0.579223E+09 | 264.39 | 0.175397E+10 | 0.494757E+09 | 0.00 | 0.78 | 15-AUG-06:02 | 0.00 | 01-AUG-00:10 | 9685.99 | 14-AUG-15:00 | 8137.39 | 14-AUG-16:00 | 4044.94 | 17-AUG-06:02 | 2354.88 | 14-AUG-15:00 | 0.00 | 01-AUG-00:10 |
September | 0.845631E+09 | 0.219549E+09 | 156.79 | 0.690978E+09 | 0.154653E+09 | 0.00 | 0.67 | 13-SEP-15:00 | 0.00 | 01-SEP-00:10 | 8293.90 | 13-SEP-15:00 | 6759.26 | 13-SEP-15:00 | 1911.72 | 12-SEP-14:10 | 2014.45 | 13-SEP-15:00 | 0.00 | 01-SEP-00:10 |
October | 18128.62 | 5137.97 | 12.50 | 17210.38 | 918.24 | 0.00 | 0.00 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 1.69 | 07-OCT-15:00 | 1.69 | 07-OCT-15:00 | 0.10 | 11-OCT-14:10 | 0.48 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.696503E+10 | 0.178233E+10 | 923.86 | 0.556621E+10 | 0.139882E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.235271E+10 | 0.598323E+09 | 264.39 | 0.188234E+10 | 0.494757E+09 | 0.00 | 1.00 | 0.00 | 27563.00 | 22617.80 | 11618.15 | 5866.98 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.164125E+10 | 0.471466E+09 | 44.10 | 0.160118E+10 | 40068746.23 | 0.00 | 1.00 | 30-APR-08:62 | 0.00 | 01-APR-00:10 | 115712.93 | 30-APR-08:62 | 105045.05 | 30-APR-08:62 | 10667.88 | 30-APR-08:62 | 27482.33 | 30-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.194761E+10 | 0.554212E+09 | 62.17 | 0.157445E+10 | 0.373164E+09 | 0.00 | 1.00 | 26-MAY-06:03 | 0.00 | 01-MAY-00:10 | 57477.17 | 24-MAY-06:03 | 38939.25 | 24-MAY-06:03 | 19180.22 | 26-MAY-06:03 | 13616.72 | 24-MAY-06:03 | 0.00 | 01-MAY-00:10 |
June | 0.958438E+10 | 0.260916E+10 | 190.72 | 0.782064E+10 | 0.176374E+10 | 0.00 | 1.00 | 13-JUN-06:02 | 0.00 | 01-JUN-00:10 | 122146.64 | 27-JUN-06:02 | 98671.88 | 25-JUN-08:62 | 52825.34 | 27-JUN-06:03 | 29024.90 | 27-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.175858E+11 | 0.485439E+10 | 268.02 | 0.142614E+11 | 0.332433E+10 | 0.00 | 1.00 | 07-JUL-06:03 | 0.00 | 01-JUL-00:10 | 121406.34 | 23-JUL-08:62 | 103749.39 | 22-JUL-06:02 | 47102.21 | 25-JUL-06:03 | 28868.11 | 23-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.192364E+11 | 0.535757E+10 | 310.28 | 0.152208E+11 | 0.401569E+10 | 0.00 | 1.00 | 02-AUG-06:03 | 0.00 | 01-AUG-00:10 | 119785.11 | 17-AUG-06:02 | 101897.71 | 15-AUG-06:02 | 46569.04 | 17-AUG-06:02 | 28505.17 | 17-AUG-06:02 | 0.00 | 01-AUG-00:10 |
September | 0.836058E+10 | 0.233798E+10 | 187.19 | 0.686057E+10 | 0.150001E+10 | 0.00 | 1.00 | 01-SEP-06:03 | 0.00 | 01-SEP-00:10 | 119131.00 | 16-SEP-06:03 | 79566.16 | 14-SEP-06:02 | 44800.43 | 16-SEP-06:03 | 28351.34 | 16-SEP-06:03 | 0.00 | 01-SEP-00:10 |
October | 50319624.98 | 15271503.09 | 20.42 | 50312998.78 | 6626.20 | 0.00 | 0.22 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 9665.60 | 07-OCT-15:00 | 9665.60 | 07-OCT-15:00 | 0.74 | 02-OCT-15:20 | 2888.62 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.584064E+11 | 0.162000E+11 | 1082.89 | 0.473893E+11 | 0.110170E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.192364E+11 | 0.535757E+10 | 310.28 | 0.152208E+11 | 0.401569E+10 | 0.00 | 1.00 | 0.00 | 122146.64 | 105045.05 | 52825.34 | 29024.90 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 6336.69 | 1793.76 | 5.67 | 5831.76 | 504.94 | 0.00 | 0.00 | 17-JAN-13:00 | 0.00 | 01-JAN-00:10 | 2.04 | 17-JAN-13:00 | 1.92 | 17-JAN-13:00 | 0.13 | 17-JAN-12:50 | 0.58 | 17-JAN-13:00 | 0.00 | 01-JAN-00:10 |
February | 4190.07 | 1184.80 | 7.56 | 4105.65 | 84.43 | 0.00 | 0.00 | 03-FEB-14:00 | 0.00 | 01-FEB-00:10 | 0.63 | 03-FEB-14:00 | 0.63 | 03-FEB-14:00 | 0.03 | 27-FEB-15:10 | 0.18 | 03-FEB-14:00 | 0.00 | 01-FEB-00:10 |
March | 4002.18 | 1131.59 | 5.67 | 3971.97 | 30.21 | 0.00 | 0.00 | 30-MAR-13:40 | 0.00 | 01-MAR-00:10 | 0.43 | 30-MAR-13:40 | 0.43 | 30-MAR-13:40 | 0.02 | 25-MAR-14:00 | 0.12 | 30-MAR-13:40 | 0.00 | 01-MAR-00:10 |
April | 0.611183E+09 | 0.148861E+09 | 125.48 | 0.594654E+09 | 16529474.27 | 0.00 | 0.87 | 30-APR-14:30 | 0.00 | 01-APR-00:10 | 15540.55 | 30-APR-08:62 | 13918.58 | 30-APR-08:62 | 1621.96 | 30-APR-08:62 | 3301.98 | 30-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.463651E+09 | 0.116067E+09 | 139.85 | 0.380678E+09 | 82973002.16 | 0.00 | 0.84 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 7840.03 | 22-MAY-15:00 | 7092.07 | 22-MAY-15:00 | 1424.66 | 23-MAY-14:10 | 1833.81 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.159843E+10 | 0.388506E+09 | 225.94 | 0.131673E+10 | 0.281702E+09 | 0.00 | 1.00 | 13-JUN-06:02 | 0.00 | 01-JUN-00:10 | 19801.53 | 27-JUN-06:02 | 14389.47 | 13-JUN-06:02 | 8698.83 | 27-JUN-06:02 | 4212.80 | 27-JUN-06:02 | 0.00 | 01-JUN-00:10 |
July | 0.314274E+10 | 0.770732E+09 | 287.02 | 0.254985E+10 | 0.592888E+09 | 0.00 | 1.00 | 13-JUL-06:02 | 0.00 | 01-JUL-00:10 | 19717.80 | 23-JUL-08:62 | 16816.58 | 22-JUL-06:02 | 7730.04 | 24-JUL-06:02 | 4196.55 | 23-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.442575E+10 | 0.106159E+10 | 328.28 | 0.351729E+10 | 0.908459E+09 | 0.00 | 1.00 | 06-AUG-08:62 | 0.00 | 01-AUG-00:10 | 19428.39 | 17-AUG-06:02 | 16448.79 | 15-AUG-06:02 | 7675.26 | 17-AUG-06:02 | 4137.36 | 17-AUG-06:02 | 0.00 | 01-AUG-00:10 |
September | 0.312148E+10 | 0.734359E+09 | 265.78 | 0.256270E+10 | 0.558788E+09 | 0.00 | 1.00 | 02-SEP-06:02 | 0.00 | 01-SEP-00:10 | 18994.73 | 02-SEP-06:02 | 13001.81 | 14-SEP-06:02 | 6600.75 | 02-SEP-06:02 | 4040.42 | 02-SEP-06:02 | 0.00 | 01-SEP-00:10 |
October | 0.299845E+09 | 77007187.40 | 94.74 | 0.284120E+09 | 15724947.64 | 0.00 | 0.68 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 | 5667.85 | 07-OCT-15:00 | 5667.85 | 07-OCT-15:00 | 432.01 | 04-OCT-13:30 | 1329.40 | 07-OCT-15:00 | 0.00 | 01-OCT-00:10 |
November | 9818.17 | 2776.99 | 12.72 | 8956.69 | 861.48 | 0.00 | 0.00 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 | 0.66 | 10-NOV-13:30 | 0.58 | 10-NOV-13:30 | 0.09 | 10-NOV-13:30 | 0.19 | 10-NOV-13:30 | 0.00 | 01-NOV-00:10 |
December | 39.64 | 11.20 | 0.50 | 39.64 | 0.00 | 0.00 | 0.00 | 18-DEC-13:00 | 0.00 | 01-DEC-00:10 | 0.05 | 18-DEC-13:00 | 0.05 | 18-DEC-13:00 | 0.00 | 18-DEC-13:00 | 0.01 | 18-DEC-13:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.136631E+11 | 0.329713E+10 | 1499.20 | 0.112060E+11 | 0.245707E+10 | 0.00 | ||||||||||||||
Minimum of Months | 39.64 | 11.20 | 0.50 | 39.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 | 0.05 | 0.00 | 0.01 | 0.00 | |||||||
Maximum of Months | 0.442575E+10 | 0.106159E+10 | 328.28 | 0.351729E+10 | 0.908459E+09 | 0.00 | 1.00 | 0.00 | 19801.53 | 16816.58 | 8698.83 | 4212.80 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 2950661.93 | 716018.84 | 2.17 | 2950661.93 | 0.00 | 0.00 | 0.08 | 04-FEB-14:30 | 0.00 | 01-FEB-00:10 | 508.48 | 04-FEB-14:30 | 508.48 | 04-FEB-14:30 | 0.00 | 04-FEB-14:30 | 122.99 | 04-FEB-14:30 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.103036E+10 | 0.223588E+09 | 117.47 | 0.102573E+10 | 4626564.22 | 0.00 | 0.84 | 30-APR-14:00 | 0.00 | 01-APR-00:10 | 6740.47 | 30-APR-13:50 | 6740.47 | 30-APR-13:50 | 177.94 | 28-APR-15:00 | 1359.61 | 30-APR-14:10 | 0.00 | 01-APR-00:10 |
May | 0.866283E+09 | 0.192694E+09 | 121.89 | 0.793680E+09 | 72602475.35 | 0.00 | 0.72 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 5770.32 | 22-MAY-15:00 | 5296.65 | 22-MAY-15:00 | 771.39 | 23-MAY-14:10 | 1218.26 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.235575E+10 | 0.518053E+09 | 263.12 | 0.206969E+10 | 0.286064E+09 | 0.00 | 0.91 | 13-JUN-16:00 | 0.00 | 01-JUN-00:10 | 7752.98 | 13-JUN-16:00 | 6953.29 | 13-JUN-16:00 | 1218.14 | 26-JUN-17:00 | 1598.14 | 13-JUN-16:00 | 0.00 | 01-JUN-00:10 |
July | 0.386806E+10 | 0.834797E+09 | 324.59 | 0.340800E+10 | 0.460058E+09 | 0.00 | 1.00 | 23-JUL-08:62 | 0.00 | 01-JUL-00:10 | 16076.74 | 23-JUL-08:62 | 14319.61 | 23-JUL-08:62 | 1757.12 | 23-JUL-08:62 | 3153.26 | 23-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.502696E+10 | 0.105714E+10 | 358.40 | 0.443526E+10 | 0.591692E+09 | 0.00 | 0.93 | 14-AUG-13:20 | 0.00 | 01-AUG-00:10 | 8031.45 | 17-AUG-14:10 | 7139.01 | 14-AUG-14:10 | 1334.80 | 17-AUG-12:20 | 1576.66 | 14-AUG-13:20 | 0.00 | 01-AUG-00:10 |
September | 0.407352E+10 | 0.848986E+09 | 302.89 | 0.370046E+10 | 0.373056E+09 | 0.00 | 1.00 | 11-SEP-13:20 | 0.00 | 01-SEP-00:10 | 9516.18 | 12-SEP-14:10 | 8443.96 | 13-SEP-14:10 | 1352.33 | 12-SEP-13:50 | 1795.71 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 |
October | 0.816980E+09 | 0.177419E+09 | 89.56 | 0.804824E+09 | 12156010.90 | 0.00 | 0.79 | 07-OCT-14:30 | 0.00 | 01-OCT-00:10 | 6166.74 | 07-OCT-14:30 | 6166.74 | 07-OCT-14:30 | 355.49 | 10-OCT-14:20 | 1226.82 | 07-OCT-14:30 | 0.00 | 01-OCT-00:10 |
November | 3631355.76 | 888869.16 | 3.67 | 3507401.58 | 123954.18 | 0.00 | 0.07 | 10-NOV-13:50 | 0.00 | 01-NOV-00:10 | 439.84 | 10-NOV-13:50 | 422.15 | 10-NOV-13:50 | 18.05 | 10-NOV-13:40 | 107.13 | 10-NOV-13:50 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.180445E+11 | 0.385428E+10 | 1583.75 | 0.162441E+11 | 0.180038E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.502696E+10 | 0.105714E+10 | 358.40 | 0.443526E+10 | 0.591692E+09 | 0.00 | 1.00 | 0.00 | 16076.74 | 14319.61 | 1757.12 | 3153.26 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 23.91 | 6.74 | 17.17 | 11.47 | 70.40 | 0.00 | 0.00 | 744.00 |
February | 41.64 | 15.02 | 26.62 | 29.33 | 67.01 | 0.00 | 0.00 | 672.00 |
March | 51.40 | 9.49 | 41.91 | 39.81 | 53.50 | 0.00 | 0.00 | 744.00 |
April | 124.80 | 66.37 | 58.43 | 135.53 | 47.63 | 0.00 | 0.00 | 720.00 |
May | 149.60 | 82.17 | 67.43 | 161.41 | 42.48 | 0.00 | 0.00 | 744.00 |
June | 160.51 | 86.53 | 73.98 | 180.06 | 34.67 | 0.00 | 0.00 | 720.00 |
July | 162.54 | 94.51 | 68.03 | 186.68 | 33.78 | 0.00 | 0.00 | 744.00 |
August | 139.46 | 83.85 | 55.60 | 160.39 | 38.87 | 0.00 | 0.00 | 744.00 |
September | 104.64 | 62.87 | 41.77 | 114.56 | 48.24 | 0.00 | 0.00 | 720.00 |
October | 50.37 | 20.64 | 29.73 | 43.83 | 56.65 | 0.00 | 0.00 | 744.00 |
November | 25.97 | 7.57 | 18.40 | 14.56 | 64.74 | 0.50 | 0.00 | 720.00 |
December | 16.54 | 4.06 | 12.48 | 5.26 | 78.98 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 87.81 | 45.11 | 42.70 | 90.51 | 53.01 | 0.50 | 0.00 | 8760.00 |
Minimum of Months | 16.54 | 4.06 | 12.48 | 5.26 | 33.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 162.54 | 94.51 | 73.98 | 186.68 | 78.98 | 0.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 911.90 | 590.22 | 321.68 | 862.17 | 836.38 | 0.00 | 0.00 | 744.00 |
February | 1114.07 | 679.84 | 434.23 | 1038.38 | 820.46 | 0.00 | 0.00 | 672.00 |
March | 688.90 | 200.68 | 488.23 | 474.09 | 686.29 | 0.00 | 0.00 | 744.00 |
April | 1430.41 | 646.61 | 783.81 | 1263.58 | 620.81 | 0.00 | 0.00 | 720.00 |
May | 1182.79 | 384.96 | 797.83 | 839.30 | 541.56 | 0.00 | 0.00 | 744.00 |
June | 1089.61 | 263.63 | 825.98 | 783.85 | 431.87 | 0.00 | 0.00 | 720.00 |
July | 1180.56 | 369.58 | 810.98 | 928.43 | 404.93 | 0.00 | 0.00 | 744.00 |
August | 1383.53 | 622.35 | 761.19 | 1271.96 | 447.37 | 0.00 | 0.00 | 744.00 |
September | 1635.60 | 958.40 | 677.20 | 1654.03 | 566.94 | 0.00 | 0.00 | 720.00 |
October | 1123.58 | 656.79 | 466.79 | 1098.80 | 697.41 | 0.00 | 0.00 | 744.00 |
November | 796.24 | 484.30 | 311.94 | 747.67 | 786.79 | 0.00 | 0.00 | 720.00 |
December | 631.02 | 404.21 | 226.80 | 586.94 | 924.81 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1095.67 | 519.77 | 575.90 | 960.17 | 646.21 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 631.02 | 200.68 | 226.80 | 474.09 | 404.93 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1635.60 | 958.40 | 825.98 | 1654.03 | 924.81 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 911.90 | 590.22 | 321.68 | 866.54 | 811.96 | 0.00 | 0.00 | 744.00 |
February | 1114.07 | 679.84 | 434.23 | 1044.80 | 793.38 | 0.00 | 0.00 | 672.00 |
March | 688.90 | 200.68 | 488.23 | 482.00 | 658.30 | 0.00 | 0.00 | 744.00 |
April | 1430.41 | 646.61 | 783.81 | 1270.91 | 592.24 | 0.00 | 0.00 | 720.00 |
May | 1182.79 | 384.96 | 797.83 | 849.55 | 512.07 | 0.00 | 0.00 | 744.00 |
June | 1089.61 | 263.63 | 825.98 | 787.63 | 411.90 | 0.00 | 0.00 | 720.00 |
July | 1180.56 | 369.58 | 810.98 | 929.39 | 387.59 | 0.00 | 0.00 | 744.00 |
August | 1383.53 | 622.35 | 761.19 | 1270.20 | 431.25 | 0.00 | 0.00 | 744.00 |
September | 1635.60 | 958.40 | 677.20 | 1653.80 | 549.02 | 0.00 | 0.00 | 720.00 |
October | 1123.58 | 656.79 | 466.79 | 1104.76 | 661.71 | 0.00 | 0.00 | 744.00 |
November | 796.24 | 484.30 | 311.94 | 754.03 | 751.62 | 0.00 | 0.00 | 720.00 |
December | 631.02 | 404.21 | 226.80 | 588.71 | 904.61 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 1095.67 | 519.77 | 575.90 | 964.58 | 621.23 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 631.02 | 200.68 | 226.80 | 482.00 | 387.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 1635.60 | 958.40 | 825.98 | 1653.80 | 904.61 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 187.64 | 121.45 | 66.19 | 175.16 | 165.81 | 0.00 | 0.00 | 744.00 |
February | 229.24 | 139.89 | 89.35 | 211.30 | 161.76 | 0.00 | 0.00 | 672.00 |
March | 141.75 | 41.29 | 100.46 | 96.47 | 134.29 | 0.00 | 0.00 | 744.00 |
April | 294.33 | 133.05 | 161.28 | 261.45 | 117.90 | 0.00 | 0.00 | 720.00 |
May | 243.38 | 79.21 | 164.17 | 175.70 | 101.44 | 0.00 | 0.00 | 744.00 |
June | 224.20 | 54.25 | 169.96 | 164.84 | 80.45 | 0.00 | 0.00 | 720.00 |
July | 242.92 | 76.05 | 166.87 | 194.43 | 75.38 | 0.00 | 0.00 | 744.00 |
August | 284.68 | 128.06 | 156.63 | 264.84 | 83.55 | 0.00 | 0.00 | 744.00 |
September | 336.55 | 197.21 | 139.34 | 341.49 | 107.42 | 0.00 | 0.00 | 720.00 |
October | 231.19 | 135.14 | 96.05 | 226.26 | 132.26 | 0.00 | 0.00 | 744.00 |
November | 163.84 | 99.65 | 64.19 | 152.73 | 153.18 | 0.00 | 0.00 | 720.00 |
December | 129.84 | 83.17 | 46.67 | 118.71 | 186.13 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 225.45 | 106.95 | 118.50 | 198.16 | 124.77 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 129.84 | 41.29 | 46.67 | 96.47 | 75.38 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 336.55 | 197.21 | 169.96 | 341.49 | 186.13 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 64040202.97 | 18040174.51 | 46000028.45 | 30718489.89 | 0.188562E+09 |
February | 0.100728E+09 | 36325385.40 | 64402881.27 | 70964101.71 | 0.162104E+09 |
March | 0.137673E+09 | 25409506.10 | 0.112264E+09 | 0.106621E+09 | 0.143287E+09 |
April | 0.323492E+09 | 0.172036E+09 | 0.151456E+09 | 0.351289E+09 | 0.123456E+09 |
May | 0.400690E+09 | 0.220078E+09 | 0.180613E+09 | 0.432325E+09 | 0.113776E+09 |
June | 0.416040E+09 | 0.224278E+09 | 0.191763E+09 | 0.466703E+09 | 89875585.76 |
July | 0.435360E+09 | 0.253148E+09 | 0.182213E+09 | 0.500006E+09 | 90468300.38 |
August | 0.373520E+09 | 0.224593E+09 | 0.148927E+09 | 0.429590E+09 | 0.104119E+09 |
September | 0.271221E+09 | 0.162954E+09 | 0.108267E+09 | 0.296950E+09 | 0.125033E+09 |
October | 0.134909E+09 | 55273492.10 | 79635977.26 | 0.117396E+09 | 0.151721E+09 |
November | 67312619.97 | 19619118.29 | 47693501.68 | 37752095.24 | 0.167819E+09 |
December | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 0.211553E+09 |
Annual Sum or Average | 0.276929E+10 | 0.142263E+10 | 0.134665E+10 | 0.285440E+10 | 0.167177E+10 |
Minimum of Months | 44300812.95 | 10879706.61 | 33421106.35 | 14088173.02 | 89875585.76 |
Maximum of Months | 0.435360E+09 | 0.253148E+09 | 0.191763E+09 | 0.500006E+09 | 0.211553E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.244243E+10 | 0.158085E+10 | 0.861581E+09 | 0.230923E+10 | 0.224016E+10 |
February | 0.269517E+10 | 0.164468E+10 | 0.105049E+10 | 0.251206E+10 | 0.198485E+10 |
March | 0.184516E+10 | 0.537497E+09 | 0.130766E+10 | 0.126981E+10 | 0.183815E+10 |
April | 0.370762E+10 | 0.167600E+10 | 0.203162E+10 | 0.327519E+10 | 0.160913E+10 |
May | 0.316798E+10 | 0.103107E+10 | 0.213691E+10 | 0.224798E+10 | 0.145053E+10 |
June | 0.282426E+10 | 0.683328E+09 | 0.214094E+10 | 0.203173E+10 | 0.111941E+10 |
July | 0.316201E+10 | 0.989887E+09 | 0.217212E+10 | 0.248670E+10 | 0.108456E+10 |
August | 0.370565E+10 | 0.166689E+10 | 0.203876E+10 | 0.340683E+10 | 0.119825E+10 |
September | 0.423948E+10 | 0.248419E+10 | 0.175529E+10 | 0.428725E+10 | 0.146952E+10 |
October | 0.300939E+10 | 0.175914E+10 | 0.125025E+10 | 0.294303E+10 | 0.186793E+10 |
November | 0.206387E+10 | 0.125531E+10 | 0.808558E+09 | 0.193797E+10 | 0.203936E+10 |
December | 0.169012E+10 | 0.108264E+10 | 0.607473E+09 | 0.157206E+10 | 0.247702E+10 |
Annual Sum or Average | 0.345531E+11 | 0.163915E+11 | 0.181617E+11 | 0.302798E+11 | 0.203789E+11 |
Minimum of Months | 0.169012E+10 | 0.537497E+09 | 0.607473E+09 | 0.126981E+10 | 0.108456E+10 |
Maximum of Months | 0.423948E+10 | 0.248419E+10 | 0.217212E+10 | 0.428725E+10 | 0.247702E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.244243E+10 | 0.158085E+10 | 0.861581E+09 | 0.232094E+10 | 0.217475E+10 |
February | 0.269517E+10 | 0.164468E+10 | 0.105049E+10 | 0.252759E+10 | 0.191936E+10 |
March | 0.184516E+10 | 0.537497E+09 | 0.130766E+10 | 0.129099E+10 | 0.176318E+10 |
April | 0.370762E+10 | 0.167600E+10 | 0.203162E+10 | 0.329419E+10 | 0.153508E+10 |
May | 0.316798E+10 | 0.103107E+10 | 0.213691E+10 | 0.227543E+10 | 0.137153E+10 |
June | 0.282426E+10 | 0.683328E+09 | 0.214094E+10 | 0.204155E+10 | 0.106766E+10 |
July | 0.316201E+10 | 0.989887E+09 | 0.217212E+10 | 0.248928E+10 | 0.103813E+10 |
August | 0.370565E+10 | 0.166689E+10 | 0.203876E+10 | 0.340210E+10 | 0.115506E+10 |
September | 0.423948E+10 | 0.248419E+10 | 0.175529E+10 | 0.428665E+10 | 0.142305E+10 |
October | 0.300939E+10 | 0.175914E+10 | 0.125025E+10 | 0.295898E+10 | 0.177232E+10 |
November | 0.206387E+10 | 0.125531E+10 | 0.808558E+09 | 0.195445E+10 | 0.194819E+10 |
December | 0.169012E+10 | 0.108264E+10 | 0.607473E+09 | 0.157679E+10 | 0.242290E+10 |
Annual Sum or Average | 0.345531E+11 | 0.163915E+11 | 0.181617E+11 | 0.304189E+11 | 0.195912E+11 |
Minimum of Months | 0.169012E+10 | 0.537497E+09 | 0.607473E+09 | 0.129099E+10 | 0.103813E+10 |
Maximum of Months | 0.423948E+10 | 0.248419E+10 | 0.217212E+10 | 0.428665E+10 | 0.242290E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.502566E+09 | 0.325283E+09 | 0.177283E+09 | 0.469144E+09 | 0.444107E+09 |
February | 0.554570E+09 | 0.338416E+09 | 0.216154E+09 | 0.511187E+09 | 0.391320E+09 |
March | 0.379669E+09 | 0.110598E+09 | 0.269071E+09 | 0.258383E+09 | 0.359679E+09 |
April | 0.762898E+09 | 0.344862E+09 | 0.418036E+09 | 0.677672E+09 | 0.305594E+09 |
May | 0.651859E+09 | 0.212158E+09 | 0.439701E+09 | 0.470599E+09 | 0.271693E+09 |
June | 0.581133E+09 | 0.140605E+09 | 0.440529E+09 | 0.427257E+09 | 0.208536E+09 |
July | 0.650630E+09 | 0.203684E+09 | 0.446946E+09 | 0.520758E+09 | 0.201906E+09 |
August | 0.762492E+09 | 0.342987E+09 | 0.419506E+09 | 0.709338E+09 | 0.223782E+09 |
September | 0.872334E+09 | 0.511157E+09 | 0.361177E+09 | 0.885138E+09 | 0.278424E+09 |
October | 0.619226E+09 | 0.361968E+09 | 0.257258E+09 | 0.606020E+09 | 0.354241E+09 |
November | 0.424671E+09 | 0.258298E+09 | 0.166373E+09 | 0.395865E+09 | 0.397043E+09 |
December | 0.347766E+09 | 0.222770E+09 | 0.124997E+09 | 0.317956E+09 | 0.498532E+09 |
Annual Sum or Average | 0.710981E+10 | 0.337279E+10 | 0.373703E+10 | 0.624932E+10 | 0.393486E+10 |
Minimum of Months | 0.347766E+09 | 0.110598E+09 | 0.124997E+09 | 0.258383E+09 | 0.201906E+09 |
Maximum of Months | 0.872334E+09 | 0.511157E+09 | 0.446946E+09 | 0.885138E+09 | 0.498532E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 183.50 | 1126.42 | 382.56 | 107.77 | 274.79 | 0.00 | 0.00 |
February | 469.34 | 1072.11 | 666.19 | 240.25 | 425.94 | 0.00 | 0.00 |
March | 636.92 | 855.96 | 822.42 | 151.79 | 670.63 | 0.00 | 0.00 |
April | 2168.45 | 762.07 | 1996.86 | 1061.95 | 934.91 | 0.00 | 0.00 |
May | 2582.59 | 679.67 | 2393.61 | 1314.68 | 1078.93 | 0.00 | 0.00 |
June | 2880.88 | 554.79 | 2568.15 | 1384.43 | 1183.72 | 0.00 | 0.00 |
July | 2986.89 | 540.43 | 2600.72 | 1512.23 | 1088.49 | 0.00 | 0.00 |
August | 2566.25 | 621.98 | 2231.30 | 1341.65 | 889.64 | 0.00 | 0.00 |
September | 1833.03 | 771.81 | 1674.20 | 1005.89 | 668.32 | 0.00 | 0.00 |
October | 701.29 | 906.34 | 805.91 | 330.19 | 475.72 | 0.00 | 0.00 |
November | 233.04 | 1035.92 | 415.51 | 121.11 | 294.40 | 0.00 | 0.00 |
December | 84.16 | 1263.76 | 264.64 | 64.99 | 199.65 | 0.00 | 0.00 |
Annual Sum or Average | 1448.20 | 848.19 | 1405.02 | 721.78 | 683.23 | 0.00 | 0.00 |
Minimum of Months | 84.16 | 540.43 | 264.64 | 64.99 | 199.65 | 0.00 | 0.00 |
Maximum of Months | 2986.89 | 1263.76 | 2600.72 | 1512.23 | 1183.72 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 862.17 | 836.38 | 911.90 | 590.22 | 321.68 | 0.00 | 0.00 |
February | 1038.38 | 820.46 | 1114.07 | 679.84 | 434.23 | 0.00 | 0.00 |
March | 474.09 | 686.29 | 688.90 | 200.68 | 488.23 | 0.00 | 0.00 |
April | 1263.58 | 620.81 | 1430.41 | 646.61 | 783.81 | 0.00 | 0.00 |
May | 839.30 | 541.56 | 1182.79 | 384.96 | 797.83 | 0.00 | 0.00 |
June | 783.85 | 431.87 | 1089.61 | 263.63 | 825.98 | 0.00 | 0.00 |
July | 928.43 | 404.93 | 1180.56 | 369.58 | 810.98 | 0.00 | 0.00 |
August | 1271.96 | 447.37 | 1383.53 | 622.35 | 761.19 | 0.00 | 0.00 |
September | 1654.03 | 566.94 | 1635.60 | 958.40 | 677.20 | 0.00 | 0.00 |
October | 1098.80 | 697.41 | 1123.58 | 656.79 | 466.79 | 0.00 | 0.00 |
November | 747.67 | 786.79 | 796.24 | 484.30 | 311.94 | 0.00 | 0.00 |
December | 586.94 | 924.81 | 631.02 | 404.21 | 226.80 | 0.00 | 0.00 |
Annual Sum or Average | 960.17 | 646.21 | 1095.67 | 519.77 | 575.90 | 0.00 | 0.00 |
Minimum of Months | 474.09 | 404.93 | 631.02 | 200.68 | 226.80 | 0.00 | 0.00 |
Maximum of Months | 1654.03 | 924.81 | 1635.60 | 958.40 | 825.98 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 866.54 | 811.96 | 911.90 | 590.22 | 321.68 | 0.00 | 0.00 |
February | 1044.80 | 793.38 | 1114.07 | 679.84 | 434.23 | 0.00 | 0.00 |
March | 482.00 | 658.30 | 688.90 | 200.68 | 488.23 | 0.00 | 0.00 |
April | 1270.91 | 592.24 | 1430.41 | 646.61 | 783.81 | 0.00 | 0.00 |
May | 849.55 | 512.07 | 1182.79 | 384.96 | 797.83 | 0.00 | 0.00 |
June | 787.63 | 411.90 | 1089.61 | 263.63 | 825.98 | 0.00 | 0.00 |
July | 929.39 | 387.59 | 1180.56 | 369.58 | 810.98 | 0.00 | 0.00 |
August | 1270.20 | 431.25 | 1383.53 | 622.35 | 761.19 | 0.00 | 0.00 |
September | 1653.80 | 549.02 | 1635.60 | 958.40 | 677.20 | 0.00 | 0.00 |
October | 1104.76 | 661.71 | 1123.58 | 656.79 | 466.79 | 0.00 | 0.00 |
November | 754.03 | 751.62 | 796.24 | 484.30 | 311.94 | 0.00 | 0.00 |
December | 588.71 | 904.61 | 631.02 | 404.21 | 226.80 | 0.00 | 0.00 |
Annual Sum or Average | 964.58 | 621.23 | 1095.67 | 519.77 | 575.90 | 0.00 | 0.00 |
Minimum of Months | 482.00 | 387.59 | 631.02 | 200.68 | 226.80 | 0.00 | 0.00 |
Maximum of Months | 1653.80 | 904.61 | 1635.60 | 958.40 | 825.98 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 175.16 | 165.81 | 187.64 | 121.45 | 66.19 | 0.00 | 0.00 |
February | 211.30 | 161.76 | 229.24 | 139.89 | 89.35 | 0.00 | 0.00 |
March | 96.47 | 134.29 | 141.75 | 41.29 | 100.46 | 0.00 | 0.00 |
April | 261.45 | 117.90 | 294.33 | 133.05 | 161.28 | 0.00 | 0.00 |
May | 175.70 | 101.44 | 243.38 | 79.21 | 164.17 | 0.00 | 0.00 |
June | 164.84 | 80.45 | 224.20 | 54.25 | 169.96 | 0.00 | 0.00 |
July | 194.43 | 75.38 | 242.92 | 76.05 | 166.87 | 0.00 | 0.00 |
August | 264.84 | 83.55 | 284.68 | 128.06 | 156.63 | 0.00 | 0.00 |
September | 341.49 | 107.42 | 336.55 | 197.21 | 139.34 | 0.00 | 0.00 |
October | 226.26 | 132.26 | 231.19 | 135.14 | 96.05 | 0.00 | 0.00 |
November | 152.73 | 153.18 | 163.84 | 99.65 | 64.19 | 0.00 | 0.00 |
December | 118.71 | 186.13 | 129.84 | 83.17 | 46.67 | 0.00 | 0.00 |
Annual Sum or Average | 198.16 | 124.77 | 225.45 | 106.95 | 118.50 | 0.00 | 0.00 |
Minimum of Months | 96.47 | 75.38 | 129.84 | 41.29 | 46.67 | 0.00 | 0.00 |
Maximum of Months | 341.49 | 186.13 | 336.55 | 197.21 | 169.96 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.491496E+09 | 0.301700E+10 | 0.102464E+10 | 0.288643E+09 | 0.736000E+09 | 0.00 | 0.00 |
February | 0.113543E+10 | 0.259366E+10 | 0.161165E+10 | 0.581206E+09 | 0.103045E+10 | 0.00 | 0.00 |
March | 0.170594E+10 | 0.229259E+10 | 0.220277E+10 | 0.406552E+09 | 0.179622E+10 | 0.00 | 0.00 |
April | 0.562063E+10 | 0.197529E+10 | 0.517587E+10 | 0.275258E+10 | 0.242329E+10 | 0.00 | 0.00 |
May | 0.691721E+10 | 0.182042E+10 | 0.641105E+10 | 0.352124E+10 | 0.288980E+10 | 0.00 | 0.00 |
June | 0.746724E+10 | 0.143801E+10 | 0.665665E+10 | 0.358844E+10 | 0.306820E+10 | 0.00 | 0.00 |
July | 0.800010E+10 | 0.144749E+10 | 0.696577E+10 | 0.405036E+10 | 0.291540E+10 | 0.00 | 0.00 |
August | 0.687343E+10 | 0.166591E+10 | 0.597631E+10 | 0.359349E+10 | 0.238282E+10 | 0.00 | 0.00 |
September | 0.475120E+10 | 0.200053E+10 | 0.433954E+10 | 0.260726E+10 | 0.173228E+10 | 0.00 | 0.00 |
October | 0.187833E+10 | 0.242754E+10 | 0.215855E+10 | 0.884376E+09 | 0.127418E+10 | 0.00 | 0.00 |
November | 0.604034E+09 | 0.268510E+10 | 0.107700E+10 | 0.313906E+09 | 0.763096E+09 | 0.00 | 0.00 |
December | 0.225411E+09 | 0.338485E+10 | 0.708813E+09 | 0.174075E+09 | 0.534738E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.456705E+11 | 0.267484E+11 | 0.443086E+11 | 0.227621E+11 | 0.215465E+11 | 0.00 | 0.00 |
Minimum of Months | 0.225411E+09 | 0.143801E+10 | 0.708813E+09 | 0.174075E+09 | 0.534738E+09 | 0.00 | 0.00 |
Maximum of Months | 0.800010E+10 | 0.338485E+10 | 0.696577E+10 | 0.405036E+10 | 0.306820E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.230923E+10 | 0.224016E+10 | 0.244243E+10 | 0.158085E+10 | 0.861581E+09 | 0.00 | 0.00 |
February | 0.251206E+10 | 0.198485E+10 | 0.269517E+10 | 0.164468E+10 | 0.105049E+10 | 0.00 | 0.00 |
March | 0.126981E+10 | 0.183815E+10 | 0.184516E+10 | 0.537497E+09 | 0.130766E+10 | 0.00 | 0.00 |
April | 0.327519E+10 | 0.160913E+10 | 0.370762E+10 | 0.167600E+10 | 0.203162E+10 | 0.00 | 0.00 |
May | 0.224798E+10 | 0.145053E+10 | 0.316798E+10 | 0.103107E+10 | 0.213691E+10 | 0.00 | 0.00 |
June | 0.203173E+10 | 0.111941E+10 | 0.282426E+10 | 0.683328E+09 | 0.214094E+10 | 0.00 | 0.00 |
July | 0.248670E+10 | 0.108456E+10 | 0.316201E+10 | 0.989887E+09 | 0.217212E+10 | 0.00 | 0.00 |
August | 0.340683E+10 | 0.119825E+10 | 0.370565E+10 | 0.166689E+10 | 0.203876E+10 | 0.00 | 0.00 |
September | 0.428725E+10 | 0.146952E+10 | 0.423948E+10 | 0.248419E+10 | 0.175529E+10 | 0.00 | 0.00 |
October | 0.294303E+10 | 0.186793E+10 | 0.300939E+10 | 0.175914E+10 | 0.125025E+10 | 0.00 | 0.00 |
November | 0.193797E+10 | 0.203936E+10 | 0.206387E+10 | 0.125531E+10 | 0.808558E+09 | 0.00 | 0.00 |
December | 0.157206E+10 | 0.247702E+10 | 0.169012E+10 | 0.108264E+10 | 0.607473E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.302798E+11 | 0.203789E+11 | 0.345531E+11 | 0.163915E+11 | 0.181617E+11 | 0.00 | 0.00 |
Minimum of Months | 0.126981E+10 | 0.108456E+10 | 0.169012E+10 | 0.537497E+09 | 0.607473E+09 | 0.00 | 0.00 |
Maximum of Months | 0.428725E+10 | 0.247702E+10 | 0.423948E+10 | 0.248419E+10 | 0.217212E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.232094E+10 | 0.217475E+10 | 0.244243E+10 | 0.158085E+10 | 0.861581E+09 | 0.00 | 0.00 |
February | 0.252759E+10 | 0.191936E+10 | 0.269517E+10 | 0.164468E+10 | 0.105049E+10 | 0.00 | 0.00 |
March | 0.129099E+10 | 0.176318E+10 | 0.184516E+10 | 0.537497E+09 | 0.130766E+10 | 0.00 | 0.00 |
April | 0.329419E+10 | 0.153508E+10 | 0.370762E+10 | 0.167600E+10 | 0.203162E+10 | 0.00 | 0.00 |
May | 0.227543E+10 | 0.137153E+10 | 0.316798E+10 | 0.103107E+10 | 0.213691E+10 | 0.00 | 0.00 |
June | 0.204155E+10 | 0.106766E+10 | 0.282426E+10 | 0.683328E+09 | 0.214094E+10 | 0.00 | 0.00 |
July | 0.248928E+10 | 0.103813E+10 | 0.316201E+10 | 0.989887E+09 | 0.217212E+10 | 0.00 | 0.00 |
August | 0.340210E+10 | 0.115506E+10 | 0.370565E+10 | 0.166689E+10 | 0.203876E+10 | 0.00 | 0.00 |
September | 0.428665E+10 | 0.142305E+10 | 0.423948E+10 | 0.248419E+10 | 0.175529E+10 | 0.00 | 0.00 |
October | 0.295898E+10 | 0.177232E+10 | 0.300939E+10 | 0.175914E+10 | 0.125025E+10 | 0.00 | 0.00 |
November | 0.195445E+10 | 0.194819E+10 | 0.206387E+10 | 0.125531E+10 | 0.808558E+09 | 0.00 | 0.00 |
December | 0.157679E+10 | 0.242290E+10 | 0.169012E+10 | 0.108264E+10 | 0.607473E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.304189E+11 | 0.195912E+11 | 0.345531E+11 | 0.163915E+11 | 0.181617E+11 | 0.00 | 0.00 |
Minimum of Months | 0.129099E+10 | 0.103813E+10 | 0.169012E+10 | 0.537497E+09 | 0.607473E+09 | 0.00 | 0.00 |
Maximum of Months | 0.428665E+10 | 0.242290E+10 | 0.423948E+10 | 0.248419E+10 | 0.217212E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.469144E+09 | 0.444107E+09 | 0.502566E+09 | 0.325283E+09 | 0.177283E+09 | 0.00 | 0.00 |
February | 0.511187E+09 | 0.391320E+09 | 0.554570E+09 | 0.338416E+09 | 0.216154E+09 | 0.00 | 0.00 |
March | 0.258383E+09 | 0.359679E+09 | 0.379669E+09 | 0.110598E+09 | 0.269071E+09 | 0.00 | 0.00 |
April | 0.677672E+09 | 0.305594E+09 | 0.762898E+09 | 0.344862E+09 | 0.418036E+09 | 0.00 | 0.00 |
May | 0.470599E+09 | 0.271693E+09 | 0.651859E+09 | 0.212158E+09 | 0.439701E+09 | 0.00 | 0.00 |
June | 0.427257E+09 | 0.208536E+09 | 0.581133E+09 | 0.140605E+09 | 0.440529E+09 | 0.00 | 0.00 |
July | 0.520758E+09 | 0.201906E+09 | 0.650630E+09 | 0.203684E+09 | 0.446946E+09 | 0.00 | 0.00 |
August | 0.709338E+09 | 0.223782E+09 | 0.762492E+09 | 0.342987E+09 | 0.419506E+09 | 0.00 | 0.00 |
September | 0.885138E+09 | 0.278424E+09 | 0.872334E+09 | 0.511157E+09 | 0.361177E+09 | 0.00 | 0.00 |
October | 0.606020E+09 | 0.354241E+09 | 0.619226E+09 | 0.361968E+09 | 0.257258E+09 | 0.00 | 0.00 |
November | 0.395865E+09 | 0.397043E+09 | 0.424671E+09 | 0.258298E+09 | 0.166373E+09 | 0.00 | 0.00 |
December | 0.317956E+09 | 0.498532E+09 | 0.347766E+09 | 0.222770E+09 | 0.124997E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.624932E+10 | 0.393486E+10 | 0.710981E+10 | 0.337279E+10 | 0.373703E+10 | 0.00 | 0.00 |
Minimum of Months | 0.258383E+09 | 0.201906E+09 | 0.347766E+09 | 0.110598E+09 | 0.124997E+09 | 0.00 | 0.00 |
Maximum of Months | 0.885138E+09 | 0.498532E+09 | 0.872334E+09 | 0.511157E+09 | 0.446946E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 4.18 | 3.24 | 2.03 | 1.05 | -4.0 | 28.28 | 62.93 | 0.00 |
February | 4.25 | 3.55 | 2.74 | 1.60 | -5.0 | 43.80 | 86.73 | 0.02 |
March | 5.90 | 4.45 | 2.76 | 1.18 | -2.0 | 68.95 | 35.00 | 0.00 |
April | 8.96 | 6.23 | 3.38 | 1.56 | -0.7 | 96.13 | 186.12 | 0.00 |
May | 9.99 | 8.06 | 6.28 | 3.35 | -0.9 | 110.92 | 199.68 | 0.02 |
June | 13.31 | 11.26 | 9.70 | 3.33 | 3.35 | 121.69 | 199.28 | 0.00 |
July | 15.02 | 12.39 | 10.49 | 3.21 | 4.48 | 111.91 | 220.83 | 0.00 |
August | 15.65 | 12.74 | 10.65 | 2.92 | 3.94 | 91.47 | 211.91 | 0.00 |
September | 13.43 | 11.01 | 9.10 | 2.64 | 1.42 | 68.72 | 198.32 | 0.01 |
October | 9.33 | 8.03 | 6.81 | 1.97 | -1.0 | 48.92 | 91.86 | 0.04 |
November | 6.66 | 5.65 | 4.54 | 2.05 | -2.3 | 30.27 | 53.24 | 0.04 |
December | 4.10 | 3.14 | 1.95 | 2.36 | -5.1 | 20.52 | 40.74 | 0.04 |
Annual Sum or Average | 9.26 | 7.50 | 5.89 | 2.27 | -0.6 | 70.25 | 132.30 | 0.02 |
Minimum of Months | 4.10 | 3.14 | 1.95 | 1.05 | -5.1 | 20.52 | 35.00 | 0.00 |
Maximum of Months | 15.65 | 12.74 | 10.65 | 3.35 | 4.48 | 121.69 | 220.83 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 29-JAN-05:00 | 9.36 | 5.00 | 3.60 | 8.35 | 0.00 | 0.00 |
February | 11.00 | 07-FEB-14:00 | 9.86 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 14.00 | 25-MAR-12:00 | 11.21 | 9.00 | 2.60 | 7.35 | 287.00 | 93.00 |
April | 24.00 | 30-APR-14:00 | 13.10 | 4.00 | 1.50 | 7.75 | 167.50 | 716.00 |
May | 24.00 | 22-MAY-14:00 | 16.06 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 27.00 | 13-JUN-16:00 | 17.51 | 12.00 | 3.10 | 12.41 | 141.50 | 652.50 |
July | 30.00 | 22-JUL-17:00 | 16.77 | 8.00 | 0.00 | 14.28 | 122.00 | 407.00 |
August | 27.00 | 14-AUG-17:19 | 14.15 | 3.33 | 2.60 | 10.37 | 133.00 | 358.83 |
September | 23.00 | 11-SEP-16:00 | 16.21 | 12.00 | 2.60 | 8.74 | 108.00 | 325.50 |
October | 19.00 | 07-OCT-14:00 | 10.08 | 1.00 | 1.50 | 2.22 | 131.00 | 540.50 |
November | 16.00 | 24-NOV-11:00 | 12.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 13.00 | 23-DEC-10:00 | 7.62 | 2.00 | 7.70 | 6.75 | 70.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.00 | 7.62 | 1.00 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 30.00 | 17.51 | 12.00 | 7.70 | 14.28 | 287.00 | 769.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.0 | 10-JAN-07:00 | -6.9 | -9.0 | 0.00 | -20.0 | 0.00 | 0.00 |
February | -4.0 | 17-FEB-06:00 | -4.0 | -4.0 | 0.00 | -20.5 | 0.00 | 0.00 |
March | -1.0 | 08-MAR-06:00 | -1.4 | -2.0 | 0.00 | -14.4 | 17.50 | 184.50 |
April | 0.00 | 08-APR-04:00 | -0.8 | -2.0 | 0.00 | -12.7 | 0.00 | 0.00 |
May | 2.00 | 06-MAY-04:00 | 1.57 | 1.00 | 3.60 | -13.7 | 12.50 | 117.00 |
June | 6.00 | 01-JUN-03:00 | 5.04 | 4.00 | 0.00 | -9.2 | 0.00 | 0.00 |
July | 7.00 | 05-JUL-04:00 | 6.47 | 6.00 | 3.10 | -7.8 | 28.00 | 155.00 |
August | 8.00 | 20-AUG-04:00 | 7.45 | 7.00 | 0.00 | -6.6 | 0.00 | 0.00 |
September | 5.00 | 20-SEP-03:00 | 5.00 | 5.00 | 2.60 | -10.0 | 0.00 | 0.00 |
October | 2.00 | 07-OCT-03:00 | 2.00 | 2.00 | 0.00 | -13.4 | 0.00 | 0.00 |
November | -2.0 | 29-NOV-01:00 | -2.0 | -2.0 | 3.10 | -10.7 | 0.00 | 0.00 |
December | -3.0 | 29-DEC-20:00 | -4.4 | -7.0 | 3.60 | -20.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -6.0 | -6.9 | -9.0 | 0.00 | -20.5 | 0.00 | 0.00 | |
Maximum of Months | 8.00 | 7.45 | 7.00 | 3.60 | -6.6 | 28.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.44 | 29-JAN-04:00 | 13.00 | 12.00 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.86 | 07-FEB-14:00 | 11.00 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.39 | 28-APR-07:00 | 16.00 | 15.00 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 16.06 | 22-MAY-14:00 | 24.00 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 19.93 | 25-JUN-17:00 | 22.00 | 19.00 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 17.29 | 22-JUL-09:00 | 26.00 | 12.00 | 4.60 | 11.46 | 224.50 | 619.50 |
August | 17.04 | 14-AUG-12:00 | 24.00 | 13.00 | 2.60 | 9.91 | 205.50 | 669.50 |
September | 16.53 | 10-SEP-15:00 | 21.00 | 14.00 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.58 | 17-OCT-14:00 | 16.00 | 12.00 | 0.00 | 12.03 | 144.00 | 44.50 |
November | 12.00 | 24-NOV-11:00 | 16.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 7.93 | 02-DEC-12:00 | 9.00 | 7.00 | 0.00 | 2.01 | 135.50 | 84.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.93 | 9.00 | 7.00 | 0.00 | 2.01 | 0.00 | 0.00 | |
Maximum of Months | 19.93 | 26.00 | 19.00 | 4.60 | 15.94 | 224.50 | 769.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.00 | 29-JAN-04:00 | 13.00 | 12.44 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.00 | 07-FEB-14:00 | 11.00 | 9.86 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.00 | 28-APR-07:00 | 16.00 | 15.39 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 12.00 | 23-MAY-07:00 | 17.00 | 13.94 | 3.10 | 5.13 | 112.00 | 719.50 |
June | 19.00 | 25-JUN-17:00 | 22.00 | 19.93 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 14.00 | 17-JUL-17:00 | 18.00 | 15.44 | 3.60 | 9.91 | 120.00 | 0.00 |
August | 16.00 | 08-AUG-12:00 | 18.00 | 16.70 | 1.50 | 11.46 | 154.00 | 0.00 |
September | 14.00 | 10-SEP-15:00 | 21.00 | 16.53 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.00 | 17-OCT-18:00 | 13.00 | 13.00 | 2.60 | 9.33 | 0.00 | 0.00 |
November | 12.00 | 08-NOV-14:00 | 12.00 | 12.00 | 0.00 | 8.15 | 93.00 | 106.00 |
December | 7.00 | 02-DEC-11:00 | 8.00 | 7.45 | 3.10 | 1.16 | 144.50 | 146.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.00 | 8.00 | 7.45 | 0.00 | 1.16 | 0.00 | 0.00 | |
Maximum of Months | 19.00 | 22.00 | 19.93 | 3.60 | 15.94 | 160.50 | 719.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 10.33 | 8.85 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 10.00 | 14.79 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 10.33 | 17.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 11.26 | 40.86 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.54 | 47.73 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 13.82 | 50.98 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 14.77 | 51.67 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 15.12 | 44.67 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 14.78 | 34.25 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.84 | 17.71 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.55 | 9.34 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 11.27 | 6.14 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.57 | 28.73 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 10.00 | 6.14 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 15.12 | 51.67 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.273158E+10 | -.230575E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -425826343.4 | 58.99 | 0.00 | 0.00 |
February | 0.249869E+10 | -.211367E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -385017839.4 | 59.00 | 0.00 | 0.00 |
March | 0.280520E+10 | -.238213E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -423067770.9 | 58.99 | 0.00 | 0.00 |
April | 0.261829E+10 | -.222200E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -396293578.2 | 59.00 | 0.00 | 0.00 |
May | 0.264364E+10 | -.223833E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -405307721.4 | 58.99 | 0.00 | 0.00 |
June | 0.251464E+10 | -.213557E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -379078645.1 | 59.00 | 0.00 | 0.00 |
July | 0.248633E+10 | -.209738E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -388950999.3 | 58.99 | 0.00 | 0.00 |
August | 0.253580E+10 | -.214767E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -388121345.7 | 58.99 | 0.00 | 0.00 |
September | 0.243829E+10 | -.205832E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -379973355.7 | 59.00 | 0.00 | 0.00 |
October | 0.255183E+10 | -.213978E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -412050904.9 | 59.00 | 0.00 | 0.00 |
November | 0.252916E+10 | -.211989E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -409269851.4 | 58.99 | 0.00 | 0.00 |
December | 0.269020E+10 | -.226307E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -427129164.6 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.310436E+11 | -.262236E+11 | 8760.00 | -.482009E+10 | 58.99 | |||||
Minimum of Months | 0.243829E+10 | -.238213E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -427129164.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.280520E+10 | -.205832E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -379078645.1 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 195.67 | 0.94 | 0.75 | 25-JAN-12:20 | 167.35 | 5.54 | 0.00 | 0.00 | 134.19 | 4.14 | 0.00 | 0.00 |
February | 217.00 | 0.88 | 0.58 | 27-FEB-11:30 | 233.66 | 7.15 | 0.00 | 0.17 | 187.44 | 5.72 | 0.00 | 0.00 |
March | 215.50 | 0.81 | 0.50 | 02-MAR-11:20 | 318.32 | 8.83 | 0.00 | 24.67 | 256.85 | 7.27 | 0.00 | 5.00 |
April | 359.67 | 0.71 | 0.50 | 01-APR-10:09 | 1000.91 | 9.85 | 0.00 | 154.00 | 890.50 | 8.32 | 0.00 | 112.83 |
May | 417.17 | 0.73 | 0.50 | 01-MAY-09:20 | 3348.35 | 10.93 | 0.00 | 169.33 | 2009.63 | 9.33 | 0.00 | 101.50 |
June | 410.67 | 0.71 | 0.50 | 01-JUN-11:09 | 1926.06 | 11.86 | 0.00 | 168.67 | 1964.24 | 10.13 | 0.00 | 112.83 |
July | 429.00 | 0.72 | 0.50 | 01-JUL-11:09 | 1970.08 | 11.16 | 0.00 | 160.33 | 2110.83 | 9.48 | 0.00 | 99.83 |
August | 396.33 | 0.73 | 0.50 | 01-AUG-09:30 | 402.76 | 9.85 | 0.00 | 126.83 | 1368.84 | 8.23 | 0.00 | 105.83 |
September | 337.67 | 0.80 | 0.50 | 01-SEP-10:09 | 327.40 | 8.33 | 0.00 | 37.67 | 267.64 | 6.84 | 0.00 | 18.67 |
October | 234.00 | 0.85 | 0.58 | 02-OCT-12:30 | 273.54 | 7.81 | 0.00 | 0.17 | 221.25 | 6.30 | 0.00 | 0.00 |
November | 171.33 | 0.92 | 0.75 | 02-NOV-12:30 | 191.75 | 6.14 | 0.00 | 0.00 | 154.55 | 4.71 | 0.00 | 0.00 |
December | 131.67 | 0.95 | 0.83 | 02-DEC-10:20 | 155.00 | 5.07 | 0.00 | 0.00 | 126.36 | 3.73 | 0.00 | 0.00 |
Annual Sum or Average | 3515.67 | 0.78 | 1118.55 | 9.26 | 0.00 | 841.83 | 1058.37 | 7.70 | 0.00 | 556.50 | ||
Minimum of Months | 131.67 | 0.71 | 0.50 | 155.00 | 5.07 | 0.00 | 0.00 | 126.36 | 3.73 | 0.00 | 0.00 | |
Maximum of Months | 429.00 | 0.95 | 0.83 | 3348.35 | 11.86 | 0.00 | 169.33 | 2110.83 | 10.13 | 0.00 | 112.83 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.657066E+10 | 41707.56 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.541093E+10 | 41707.56 | 01-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.382188E+10 | 41707.56 | 01-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.819123E+09 | 41707.56 | 01-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.260729E+09 | 29578.35 | 06-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.839642E+09 | 41707.56 | 23-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.344615E+10 | 41707.56 | 03-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.705113E+10 | 41707.56 | 01-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.282202E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.705113E+10 | 41707.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.286076E+11 | 207450.11 | 10-JAN-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.227133E+11 | 171619.87 | 20-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.178993E+11 | 133729.99 | 06-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.375141E+10 | 60103.09 | 08-APR-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.768557E+09 | 32949.36 | 06-MAY-06:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.394754E+10 | 40665.92 | 28-OCT-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.157435E+11 | 149439.96 | 20-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.301157E+11 | 200127.80 | 26-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.123547E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.301157E+11 | 207450.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.166509E+10 | 32433.81 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.114337E+10 | 32433.81 | 17-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.107579E+10 | 26733.40 | 06-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.149566E+09 | 7796.52 | 01-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 57894080.74 | 3454.72 | 06-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.153342E+09 | 4830.45 | 28-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.734703E+09 | 22871.92 | 27-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.223929E+10 | 32433.81 | 03-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.721904E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.223929E+10 | 32433.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.344106E+10 | 27187.69 | 01-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.265423E+10 | 27187.69 | 02-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.266552E+10 | 27187.69 | 04-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.551533E+09 | 19175.71 | 01-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.300040E+09 | 18609.35 | 06-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 10214818.62 | 12486.68 | 08-JUN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 2358481.66 | 7055.88 | 05-JUL-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 1224785.60 | 1693.92 | 20-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.601712E+09 | 18646.79 | 23-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.197216E+10 | 27187.69 | 19-NOV-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.432515E+10 | 27187.69 | 01-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.165252E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.432515E+10 | 27187.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.112714E+11 | 28900.10 | 11-JAN-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.950064E+10 | 21325.55 | 16-FEB-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.931378E+10 | 22534.00 | 15-MAR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.513105E+10 | 14871.89 | 10-APR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.509877E+10 | 13437.44 | 04-MAY-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.255404E+10 | 11541.75 | 07-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.125563E+10 | 8279.57 | 04-JUL-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.374597E+09 | 3531.11 | 11-AUG-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.162874E+10 | 9058.96 | 08-SEP-11:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.542822E+10 | 13368.94 | 27-OCT-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.885749E+10 | 22897.58 | 28-NOV-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.115682E+11 | 26527.34 | 29-DEC-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.719826E+11 | |||||||
Minimum of Months | 0.374597E+09 | 3531.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.115682E+11 | 28900.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.146199E+09 | 0.141755E+09 | 4976.29 | 30-APR-15:30 | 4976.29 | 0.00 |
May | 0.00 | 0.00 | 0.141797E+09 | 0.114754E+09 | 6685.50 | 22-MAY-15:00 | 5706.27 | 0.00 |
June | 0.00 | 0.00 | 0.122995E+10 | 0.982390E+09 | 25147.11 | 27-JUN-06:02 | 13528.96 | 0.00 |
July | 0.00 | 0.00 | 0.235271E+10 | 0.188234E+10 | 27563.00 | 23-JUL-08:62 | 20748.55 | 0.00 |
August | 0.00 | 0.00 | 0.224873E+10 | 0.175397E+10 | 9685.99 | 14-AUG-15:00 | 8086.04 | 0.00 |
September | 0.00 | 0.00 | 0.845631E+09 | 0.690978E+09 | 8293.90 | 13-SEP-15:00 | 6759.26 | 0.00 |
October | 0.00 | 0.00 | 18128.62 | 17210.38 | 1.69 | 07-OCT-15:00 | 1.69 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.696503E+10 | 0.556621E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.235271E+10 | 0.188234E+10 | 27563.00 | 20748.55 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.164125E+10 | 0.160118E+10 | 115712.93 | 30-APR-08:62 | 105045.05 | 0.00 |
May | 0.00 | 0.00 | 0.194761E+10 | 0.157445E+10 | 57477.17 | 24-MAY-06:03 | 38939.25 | 0.00 |
June | 0.00 | 0.00 | 0.958438E+10 | 0.782064E+10 | 122146.64 | 27-JUN-06:02 | 69707.54 | 0.00 |
July | 0.00 | 0.00 | 0.175858E+11 | 0.142614E+11 | 121406.34 | 23-JUL-08:62 | 94897.30 | 0.00 |
August | 0.00 | 0.00 | 0.192364E+11 | 0.152208E+11 | 119785.11 | 17-AUG-06:02 | 73216.06 | 0.00 |
September | 0.00 | 0.00 | 0.836058E+10 | 0.686057E+10 | 119131.00 | 16-SEP-06:03 | 74330.57 | 0.00 |
October | 0.00 | 0.00 | 50319624.98 | 50312998.78 | 9665.60 | 07-OCT-15:00 | 9665.60 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.584064E+11 | 0.473893E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.192364E+11 | 0.152208E+11 | 122146.64 | 105045.05 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 6336.69 | 5831.76 | 2.04 | 17-JAN-13:00 | 1.92 | 0.00 |
February | 0.00 | 0.00 | 4190.07 | 4105.65 | 0.63 | 03-FEB-14:00 | 0.63 | 0.00 |
March | 0.00 | 0.00 | 4002.18 | 3971.97 | 0.43 | 30-MAR-13:40 | 0.43 | 0.00 |
April | 0.00 | 0.00 | 0.611183E+09 | 0.594654E+09 | 15540.55 | 30-APR-08:62 | 13918.58 | 0.00 |
May | 0.00 | 0.00 | 0.463651E+09 | 0.380678E+09 | 7840.03 | 22-MAY-15:00 | 7092.07 | 0.00 |
June | 0.00 | 0.00 | 0.159843E+10 | 0.131673E+10 | 19801.53 | 27-JUN-06:02 | 11102.70 | 0.00 |
July | 0.00 | 0.00 | 0.314274E+10 | 0.254985E+10 | 19717.80 | 23-JUL-08:62 | 15171.77 | 0.00 |
August | 0.00 | 0.00 | 0.442575E+10 | 0.351729E+10 | 19428.39 | 17-AUG-06:02 | 11753.13 | 0.00 |
September | 0.00 | 0.00 | 0.312148E+10 | 0.256270E+10 | 18994.73 | 02-SEP-06:02 | 12393.98 | 0.00 |
October | 0.00 | 0.00 | 0.299845E+09 | 0.284120E+09 | 5667.85 | 07-OCT-15:00 | 5667.85 | 0.00 |
November | 0.00 | 0.00 | 9818.17 | 8956.69 | 0.66 | 10-NOV-13:30 | 0.58 | 0.00 |
December | 0.00 | 0.00 | 39.64 | 39.64 | 0.05 | 18-DEC-13:00 | 0.05 | 0.00 |
Annual Sum or Average | 0.136631E+11 | 0.112060E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 39.64 | 39.64 | 0.05 | 0.05 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.442575E+10 | 0.351729E+10 | 19801.53 | 15171.77 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 2950661.93 | 2950661.93 | 508.48 | 04-FEB-14:30 | 508.48 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.103036E+10 | 0.102573E+10 | 6740.47 | 30-APR-13:50 | 6740.47 | 0.00 |
May | 0.00 | 0.00 | 0.866283E+09 | 0.793680E+09 | 5770.32 | 22-MAY-15:00 | 5296.65 | 0.00 |
June | 0.00 | 0.00 | 0.235575E+10 | 0.206969E+10 | 7752.98 | 13-JUN-16:00 | 6953.29 | 0.00 |
July | 0.00 | 0.00 | 0.386806E+10 | 0.340800E+10 | 16076.74 | 23-JUL-08:62 | 14319.61 | 0.00 |
August | 0.00 | 0.00 | 0.502696E+10 | 0.443526E+10 | 8031.45 | 17-AUG-14:10 | 6801.21 | 0.00 |
September | 0.00 | 0.00 | 0.407352E+10 | 0.370046E+10 | 9516.18 | 12-SEP-14:10 | 8184.24 | 0.00 |
October | 0.00 | 0.00 | 0.816980E+09 | 0.804824E+09 | 6166.74 | 07-OCT-14:30 | 6166.74 | 0.00 |
November | 0.00 | 0.00 | 3631355.76 | 3507401.58 | 439.84 | 10-NOV-13:50 | 422.15 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.180445E+11 | 0.162441E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.502696E+10 | 0.443526E+10 | 16076.74 | 14319.61 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.262358E+10 | 0.49 | 1780.96 | 01-JAN-07:03 | 0.89 |
February | 0.236034E+10 | 0.49 | 1780.96 | 01-FEB-06:03 | 0.88 |
March | 0.261545E+10 | 0.49 | 1780.96 | 01-MAR-06:03 | 0.89 |
April | 0.215689E+10 | 0.41 | 1780.96 | 01-APR-05:03 | 0.89 |
May | 0.224741E+10 | 0.42 | 1780.96 | 01-MAY-07:10 | 0.89 |
June | 0.176054E+10 | 0.34 | 1780.96 | 01-JUN-07:10 | 0.88 |
July | 0.149908E+10 | 0.28 | 1780.96 | 01-JUL-07:10 | 0.88 |
August | 0.114995E+10 | 0.21 | 1780.96 | 01-AUG-07:06 | 0.88 |
September | 0.145090E+10 | 0.28 | 1780.96 | 01-SEP-07:10 | 0.88 |
October | 0.235756E+10 | 0.44 | 1780.96 | 01-OCT-07:03 | 0.88 |
November | 0.246626E+10 | 0.47 | 1780.96 | 01-NOV-06:03 | 0.89 |
December | 0.269162E+10 | 0.50 | 1780.96 | 01-DEC-05:07 | 0.89 |
Annual Sum or Average | 0.253796E+11 | 0.40 | |||
Minimum of Months | 0.114995E+10 | 0.21 | 1780.96 | 0.88 | |
Maximum of Months | 0.269162E+10 | 0.50 | 1780.96 | 0.89 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.123909E+10 | 0.35 | 1685.03 | 01-JAN-08:61 | 0.89 |
February | 0.111149E+10 | 0.35 | 1685.03 | 01-FEB-07:03 | 0.88 |
March | 0.119182E+10 | 0.34 | 1685.03 | 01-MAR-07:03 | 0.88 |
April | 0.107536E+10 | 0.33 | 1685.03 | 01-APR-06:03 | 0.89 |
May | 0.109579E+10 | 0.32 | 1391.01 | 06-MAY-06:03 | 0.81 |
June | 0.106286E+10 | 0.32 | 1500.60 | 27-JUN-06:02 | 0.83 |
July | 0.108265E+10 | 0.32 | 1685.03 | 22-JUL-06:02 | 0.88 |
August | 0.109918E+10 | 0.32 | 674.01 | 01-AUG-11:10 | 0.53 |
September | 0.105550E+10 | 0.32 | 674.01 | 01-SEP-12:50 | 0.53 |
October | 0.110012E+10 | 0.32 | 1685.03 | 23-OCT-06:03 | 0.88 |
November | 0.112448E+10 | 0.33 | 1685.03 | 03-NOV-06:03 | 0.89 |
December | 0.125312E+10 | 0.35 | 1685.03 | 01-DEC-06:02 | 0.88 |
Annual Sum or Average | 0.134915E+11 | 0.33 | |||
Minimum of Months | 0.105550E+10 | 0.32 | 674.01 | 0.53 | |
Maximum of Months | 0.125312E+10 | 0.35 | 1685.03 | 0.89 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.870877E+10 | 0.54 | 11773.23 | 10-JAN-07:03 | 1.38 |
February | 0.779748E+10 | 0.54 | 10575.62 | 20-FEB-09:02 | 1.31 |
March | 0.849023E+10 | 0.54 | 9309.17 | 06-MAR-07:03 | 1.23 |
April | 0.770484E+10 | 0.52 | 12098.28 | 30-APR-08:62 | 1.39 |
May | 0.784798E+10 | 0.51 | 5940.63 | 06-MAY-06:20 | 0.96 |
June | 0.764563E+10 | 0.51 | 12098.28 | 13-JUN-06:02 | 1.38 |
July | 0.779690E+10 | 0.50 | 12098.28 | 07-JUL-06:03 | 1.39 |
August | 0.791742E+10 | 0.51 | 12098.28 | 02-AUG-06:03 | 1.39 |
September | 0.758602E+10 | 0.51 | 12098.28 | 01-SEP-06:03 | 1.38 |
October | 0.788452E+10 | 0.51 | 6198.55 | 28-OCT-06:10 | 0.98 |
November | 0.800005E+10 | 0.52 | 9834.27 | 20-NOV-07:03 | 1.27 |
December | 0.877660E+10 | 0.55 | 11528.48 | 26-DEC-06:01 | 1.37 |
Annual Sum or Average | 0.961565E+11 | 0.52 | |||
Minimum of Months | 0.758602E+10 | 0.50 | 5940.63 | 0.96 | |
Maximum of Months | 0.877660E+10 | 0.55 | 12098.28 | 1.39 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.881029E+09 | 0.34 | 1311.83 | 01-JAN-08:61 | 0.92 |
February | 0.790918E+09 | 0.34 | 1311.83 | 17-FEB-06:01 | 0.92 |
March | 0.881841E+09 | 0.34 | 1173.49 | 06-MAR-06:02 | 0.87 |
April | 0.825438E+09 | 0.34 | 1040.44 | 30-APR-08:62 | 0.82 |
May | 0.849583E+09 | 0.33 | 608.57 | 06-MAY-06:05 | 0.61 |
June | 0.827798E+09 | 0.34 | 1311.83 | 13-JUN-06:02 | 0.91 |
July | 0.844505E+09 | 0.33 | 1311.83 | 13-JUL-06:02 | 0.91 |
August | 0.856731E+09 | 0.34 | 1311.83 | 06-AUG-08:62 | 0.91 |
September | 0.824599E+09 | 0.33 | 1311.83 | 02-SEP-06:02 | 0.91 |
October | 0.844343E+09 | 0.33 | 641.96 | 28-OCT-06:03 | 0.63 |
November | 0.828226E+09 | 0.33 | 1079.78 | 27-NOV-06:02 | 0.84 |
December | 0.896853E+09 | 0.35 | 1311.83 | 03-DEC-08:61 | 0.92 |
Annual Sum or Average | 0.101519E+11 | 0.34 | |||
Minimum of Months | 0.790918E+09 | 0.33 | 608.57 | 0.61 | |
Maximum of Months | 0.896853E+09 | 0.35 | 1311.83 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.169415E+10 | 0.55 | 1057.46 | 01-JAN-15:40 | 0.92 |
February | 0.153797E+10 | 0.55 | 1057.46 | 01-FEB-06:53 | 0.91 |
March | 0.172450E+10 | 0.56 | 1057.46 | 01-MAR-12:10 | 0.91 |
April | 0.165598E+10 | 0.55 | 1057.46 | 01-APR-06:17 | 0.92 |
May | 0.170928E+10 | 0.55 | 1057.46 | 03-MAY-07:50 | 0.92 |
June | 0.166740E+10 | 0.55 | 1057.46 | 06-JUN-17:30 | 0.91 |
July | 0.169785E+10 | 0.55 | 1057.46 | 03-JUL-16:50 | 0.91 |
August | 0.172450E+10 | 0.55 | 1057.46 | 04-AUG-19:17 | 0.91 |
September | 0.165598E+10 | 0.55 | 1057.46 | 08-SEP-16:40 | 0.91 |
October | 0.169405E+10 | 0.55 | 1057.46 | 04-OCT-09:30 | 0.91 |
November | 0.163314E+10 | 0.54 | 1057.46 | 02-NOV-05:20 | 0.91 |
December | 0.169833E+10 | 0.55 | 1057.46 | 01-DEC-15:30 | 0.92 |
Annual Sum or Average | 0.200931E+11 | 0.55 | |||
Minimum of Months | 0.153797E+10 | 0.54 | 1057.46 | 0.91 | |
Maximum of Months | 0.172450E+10 | 0.56 | 1057.46 | 0.92 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.12 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.04 | 0.00 |
Annual Sum or Average | 0.17 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.12 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.76 | 25.84 |
May | 1.63 | 25.84 |
June | 1.17 | 25.84 |
July | 1.03 | 25.84 |
August | 0.10 | 25.84 |
September | 1.42 | 25.84 |
October | 1.49 | 25.84 |
November | 0.08 | 25.84 |
December | 0.00 | 0.00 |
Annual Sum or Average | 7.67 | 25.84 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.63 | 25.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.29 | 2.44 |
May | 0.33 | 2.44 |
June | 0.28 | 0.00 |
July | 0.14 | 0.00 |
August | 0.04 | 2.44 |
September | 0.35 | 2.44 |
October | 0.85 | 2.44 |
November | 0.17 | 2.44 |
December | 0.00 | 0.00 |
Annual Sum or Average | 2.44 | 2.02 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.85 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.10 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.39 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.47 | 0.00 |
Annual Sum or Average | 0.96 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.47 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 24.03 | 0.00 |
February | 26.07 | 0.00 |
March | 25.88 | 0.00 |
April | 8.83 | 0.00 |
May | 11.02 | 0.00 |
June | 23.61 | 0.00 |
July | 38.15 | 0.00 |
August | 29.15 | 0.00 |
September | 25.32 | 0.00 |
October | 11.44 | 0.00 |
November | 17.36 | 0.00 |
December | 34.70 | 0.00 |
Annual Sum or Average | 275.57 | 0.00 |
Minimum of Months | 8.83 | 0.00 |
Maximum of Months | 38.15 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.123909E+10 | 0.821332E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.111149E+10 | 0.676367E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.119182E+10 | 0.477735E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.111461E+10 | 0.102390E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.113343E+10 | 0.325911E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.137120E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.168098E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.167840E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.127505E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.110012E+10 | 0.104955E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.112448E+10 | 0.430769E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.125312E+10 | 0.881392E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.152738E+11 | 0.352753E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.110012E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.168098E+10 | 0.881392E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.870877E+10 | 0.357595E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.779748E+10 | 0.283916E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.849023E+10 | 0.223741E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.817631E+10 | 0.468926E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.840219E+10 | 0.960696E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.102548E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.126513E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.132750E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.992400E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.789980E+10 | 0.493442E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.800005E+10 | 0.196794E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.877660E+10 | 0.376447E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.112356E+12 | 0.154434E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.779748E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.132750E+11 | 0.376447E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.881031E+09 | 0.208136E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.790919E+09 | 0.142921E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.881842E+09 | 0.134473E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.974299E+09 | 0.186957E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.965650E+09 | 72367600.93 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.121630E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.161524E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.191833E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.155896E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.921350E+09 | 0.191678E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.828229E+09 | 0.918378E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.896853E+09 | 0.279912E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.134490E+11 | 0.902381E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.790919E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.191833E+10 | 0.279912E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.169415E+10 | 0.430132E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.153868E+10 | 0.331779E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.172450E+10 | 0.333191E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.187957E+10 | 0.689417E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.190197E+10 | 0.375050E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.218545E+10 | 12768523.27 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.253265E+10 | 2948102.07 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.278164E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.250497E+10 | 1530981.99 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.187147E+10 | 0.752140E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.163403E+10 | 0.246519E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.169833E+10 | 0.540644E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.239474E+11 | 0.206565E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.153868E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.278164E+10 | 0.540644E+10 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.123909E+10 | 0.00 | 0.657066E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.111149E+10 | 0.00 | 0.541093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.119182E+10 | 0.00 | 0.382188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.107536E+10 | 0.146199E+09 | 0.819123E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.109579E+10 | 0.141797E+09 | 0.260729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.106286E+10 | 0.122995E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.108265E+10 | 0.235271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.109918E+10 | 0.224873E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.105550E+10 | 0.845631E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.110012E+10 | 18128.62 | 0.839642E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.112448E+10 | 0.00 | 0.344615E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.125312E+10 | 0.00 | 0.705113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.134915E+11 | 0.696503E+10 | 0.282202E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.105550E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.125312E+10 | 0.235271E+10 | 0.705113E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.870877E+10 | 0.00 | 0.286076E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.779748E+10 | 0.00 | 0.227133E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.849023E+10 | 0.00 | 0.178993E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.770484E+10 | 0.164125E+10 | 0.375141E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.784798E+10 | 0.194761E+10 | 0.768557E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.764563E+10 | 0.958438E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.779690E+10 | 0.175858E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.791742E+10 | 0.192364E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.758602E+10 | 0.836058E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.788452E+10 | 50319624.98 | 0.394754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.800005E+10 | 0.00 | 0.157435E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.877660E+10 | 0.00 | 0.301157E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.961565E+11 | 0.584064E+11 | 0.123547E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.758602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.877660E+10 | 0.192364E+11 | 0.301157E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.881029E+09 | 6336.69 | 0.166509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.790918E+09 | 4190.07 | 0.114337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.881841E+09 | 4002.18 | 0.107579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.825438E+09 | 0.611183E+09 | 0.149566E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.849583E+09 | 0.463651E+09 | 57894080.74 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.827798E+09 | 0.159843E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.844505E+09 | 0.314274E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.856731E+09 | 0.442575E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.824599E+09 | 0.312148E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.844343E+09 | 0.299845E+09 | 0.153342E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.828226E+09 | 9818.17 | 0.734703E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.896853E+09 | 39.64 | 0.223929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101519E+11 | 0.136631E+11 | 0.721904E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.790918E+09 | 39.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.896853E+09 | 0.442575E+10 | 0.223929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.169415E+10 | 0.00 | 0.344106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153797E+10 | 2950661.93 | 0.265423E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.172450E+10 | 0.00 | 0.266552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.165598E+10 | 0.103036E+10 | 0.551533E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.170928E+10 | 0.866283E+09 | 0.300040E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.166740E+10 | 0.235575E+10 | 10214818.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.169785E+10 | 0.386806E+10 | 2358481.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.172450E+10 | 0.502696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.165598E+10 | 0.407352E+10 | 1224785.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.169405E+10 | 0.816980E+09 | 0.601712E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.163314E+10 | 3631355.76 | 0.197216E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.169833E+10 | 0.00 | 0.432515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.200931E+11 | 0.180445E+11 | 0.165252E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.153797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.172450E+10 | 0.502696E+10 | 0.432515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.123909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.821332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.111149E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.676367E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.119182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.477735E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.107536E+10 | 0.00 | 0.00 | 0.00 | 39252572.01 | 0.00 | 0.102390E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.109579E+10 | 0.00 | 0.00 | 0.00 | 37637348.73 | 0.00 | 0.325911E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.106286E+10 | 0.00 | 0.00 | 0.00 | 0.308341E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.108265E+10 | 0.00 | 0.00 | 0.00 | 0.598323E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.109918E+10 | 0.00 | 0.00 | 0.00 | 0.579223E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.105550E+10 | 0.00 | 0.00 | 0.00 | 0.219549E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.110012E+10 | 0.00 | 0.00 | 0.00 | 5137.97 | 0.00 | 0.104955E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.112448E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.430769E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.125312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.881392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.134915E+11 | 0.00 | 0.00 | 0.00 | 0.178233E+10 | 0.00 | 0.352753E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.105550E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.125312E+10 | 0.00 | 0.00 | 0.00 | 0.598323E+09 | 0.00 | 0.881392E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.870877E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.357595E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.779748E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.283916E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.849023E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223741E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.770484E+10 | 0.00 | 0.00 | 0.00 | 0.471466E+09 | 0.00 | 0.468926E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.784798E+10 | 0.00 | 0.00 | 0.00 | 0.554212E+09 | 0.00 | 0.960696E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.764563E+10 | 0.00 | 0.00 | 0.00 | 0.260916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.779690E+10 | 0.00 | 0.00 | 0.00 | 0.485439E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.791742E+10 | 0.00 | 0.00 | 0.00 | 0.535757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.758602E+10 | 0.00 | 0.00 | 0.00 | 0.233798E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.788452E+10 | 0.00 | 0.00 | 0.00 | 15271503.09 | 0.00 | 0.493442E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.800005E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196794E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.877660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.961565E+11 | 0.00 | 0.00 | 0.00 | 0.162000E+11 | 0.00 | 0.154434E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.758602E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.877660E+10 | 0.00 | 0.00 | 0.00 | 0.535757E+10 | 0.00 | 0.376447E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.881029E+09 | 0.00 | 0.00 | 0.00 | 1793.76 | 0.00 | 0.208136E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.790918E+09 | 0.00 | 0.00 | 0.00 | 1184.80 | 0.00 | 0.142921E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.881841E+09 | 0.00 | 0.00 | 0.00 | 1131.59 | 0.00 | 0.134473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.825438E+09 | 0.00 | 0.00 | 0.00 | 0.148861E+09 | 0.00 | 0.186957E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.849583E+09 | 0.00 | 0.00 | 0.00 | 0.116067E+09 | 0.00 | 72367600.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.827798E+09 | 0.00 | 0.00 | 0.00 | 0.388506E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.844505E+09 | 0.00 | 0.00 | 0.00 | 0.770732E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.856731E+09 | 0.00 | 0.00 | 0.00 | 0.106159E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.824599E+09 | 0.00 | 0.00 | 0.00 | 0.734359E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.844343E+09 | 0.00 | 0.00 | 0.00 | 77007187.40 | 0.00 | 0.191678E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.828226E+09 | 0.00 | 0.00 | 0.00 | 2776.99 | 0.00 | 0.918378E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.896853E+09 | 0.00 | 0.00 | 0.00 | 11.20 | 0.00 | 0.279912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.101519E+11 | 0.00 | 0.00 | 0.00 | 0.329713E+10 | 0.00 | 0.902381E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.790918E+09 | 0.00 | 0.00 | 0.00 | 11.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.896853E+09 | 0.00 | 0.00 | 0.00 | 0.106159E+10 | 0.00 | 0.279912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.169415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.430132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.153797E+10 | 0.00 | 0.00 | 0.00 | 716018.84 | 0.00 | 0.331779E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.172450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.333191E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.165598E+10 | 0.00 | 0.00 | 0.00 | 0.223588E+09 | 0.00 | 0.689417E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.170928E+10 | 0.00 | 0.00 | 0.00 | 0.192694E+09 | 0.00 | 0.375050E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.166740E+10 | 0.00 | 0.00 | 0.00 | 0.518053E+09 | 0.00 | 12768523.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.169785E+10 | 0.00 | 0.00 | 0.00 | 0.834797E+09 | 0.00 | 2948102.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.172450E+10 | 0.00 | 0.00 | 0.00 | 0.105714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.165598E+10 | 0.00 | 0.00 | 0.00 | 0.848986E+09 | 0.00 | 1530981.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.169405E+10 | 0.00 | 0.00 | 0.00 | 0.177419E+09 | 0.00 | 0.752140E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.163314E+10 | 0.00 | 0.00 | 0.00 | 888869.16 | 0.00 | 0.246519E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.169833E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.200931E+11 | 0.00 | 0.00 | 0.00 | 0.385428E+10 | 0.00 | 0.206565E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.153797E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.172450E+10 | 0.00 | 0.00 | 0.00 | 0.105714E+10 | 0.00 | 0.540644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.421665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.410089E+10 | 0.00 | 0.00 | 0.20 |
February | 0.416132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313075E+10 | 0.00 | 0.00 | 0.20 |
March | 0.581334E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.184353E+10 | 0.00 | 0.00 | 0.21 |
April | 0.504207E+10 | 0.00 | 0.00 | 1298866.96 | 579190.48 | 0.431300E+09 | 0.113436E+10 | 0.00 | 0.24 |
May | 0.471855E+10 | 0.00 | 0.00 | 2346509.00 | 0.00 | 0.115809E+09 | 0.196469E+10 | 0.00 | 0.25 |
June | 0.135308E+10 | 26179669.21 | 0.00 | 8758239.52 | 0.00 | 0.00 | 0.571545E+10 | 0.00 | 0.36 |
July | 0.802732E+09 | 16976506.35 | 0.00 | 12320558.05 | 0.00 | 0.00 | 0.632016E+10 | 0.00 | 0.44 |
August | 0.622350E+09 | 0.00 | 0.00 | 12677760.45 | 0.00 | 0.00 | 0.665499E+10 | 0.00 | 0.50 |
September | 0.158718E+10 | 0.00 | 0.00 | 7484577.89 | 0.00 | 0.00 | 0.521483E+10 | 0.00 | 0.37 |
October | 0.547548E+10 | 0.00 | 0.00 | 350920.56 | 0.00 | 0.391264E+09 | 0.543987E+09 | 0.00 | 0.21 |
November | 0.517665E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175745E+10 | 0.00 | 0.00 | 0.20 |
December | 0.389500E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.428004E+10 | 0.00 | 0.00 | 0.20 |
Annual Sum or Average | 0.428644E+11 | 43156175.55 | 0.00 | 45237432.43 | 579190.48 | 0.160510E+11 | 0.275485E+11 | 0.00 | 0.28 |
Minimum of Months | 0.622350E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.20 |
Maximum of Months | 0.581334E+10 | 26179669.21 | 0.00 | 12677760.45 | 579190.48 | 0.428004E+10 | 0.665499E+10 | 0.00 | 0.50 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.564168E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.567707E+10 | 0.00 | 0.00 | 0.39 |
February | 0.504458E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.431259E+10 | 0.00 | 0.00 | 0.39 |
March | 0.532814E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.297755E+10 | 0.00 | 0.00 | 0.40 |
April | 0.380643E+11 | 0.00 | 0.00 | 10844674.23 | 1827123.16 | 0.209573E+09 | 0.828175E+10 | 0.00 | 0.43 |
May | 0.338519E+11 | 0.00 | 0.00 | 19002386.41 | 0.00 | 7909648.19 | 0.144836E+11 | 0.00 | 0.44 |
June | 0.961531E+10 | 0.183134E+09 | 0.00 | 58550147.53 | 0.00 | 0.00 | 0.337013E+11 | 0.00 | 0.53 |
July | 0.546529E+10 | 0.161460E+09 | 0.00 | 78619394.45 | 0.00 | 0.00 | 0.331290E+11 | 0.00 | 0.58 |
August | 0.365617E+10 | 0.00 | 0.00 | 82536436.16 | 0.00 | 0.00 | 0.335877E+11 | 0.00 | 0.63 |
September | 0.111594E+11 | 0.00 | 0.00 | 52384435.22 | 0.00 | 0.00 | 0.302712E+11 | 0.00 | 0.54 |
October | 0.412542E+11 | 0.00 | 0.00 | 4655484.91 | 0.00 | 0.179172E+09 | 0.547952E+10 | 0.00 | 0.40 |
November | 0.497111E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215479E+10 | 0.00 | 0.00 | 0.39 |
December | 0.553061E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.676081E+10 | 0.00 | 0.00 | 0.39 |
Annual Sum or Average | 0.408228E+12 | 0.344594E+09 | 0.00 | 0.306593E+09 | 1827123.16 | 0.222795E+11 | 0.158934E+12 | 0.00 | 0.46 |
Minimum of Months | 0.365617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.39 |
Maximum of Months | 0.564168E+11 | 0.183134E+09 | 0.00 | 82536436.16 | 1827123.16 | 0.676081E+10 | 0.337013E+11 | 0.00 | 0.63 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.484975E+10 | 0.00 | 0.00 | 721634.98 | 0.00 | 0.571297E+09 | 0.723090E+09 | 0.00 | 0.40 |
February | 0.422295E+10 | 0.00 | 0.00 | 680814.07 | 0.00 | 0.446044E+09 | 0.779348E+09 | 0.00 | 0.40 |
March | 0.460741E+10 | 0.00 | 0.00 | 374258.79 | 0.00 | 0.487528E+09 | 0.485943E+09 | 0.00 | 0.40 |
April | 0.169845E+10 | 14294.66 | 0.00 | 7010754.51 | 54733.20 | 28790400.43 | 0.437235E+10 | 0.00 | 0.61 |
May | 0.144123E+10 | 0.00 | 0.00 | 6880999.47 | 0.00 | 3562974.60 | 0.455450E+10 | 0.00 | 0.61 |
June | 0.401902E+09 | 42695660.29 | 0.00 | 10939096.55 | 0.00 | 0.00 | 0.552440E+10 | 0.00 | 0.85 |
July | 0.227758E+09 | 30600533.07 | 0.00 | 13893534.38 | 0.00 | 0.00 | 0.510621E+10 | 0.00 | 0.95 |
August | 0.114955E+09 | 3959866.78 | 0.00 | 17034934.42 | 0.00 | 0.00 | 0.495049E+10 | 0.00 | 1.08 |
September | 0.393842E+09 | 2498328.43 | 0.00 | 15236523.79 | 0.00 | 0.00 | 0.555171E+10 | 0.00 | 0.97 |
October | 0.225506E+10 | 0.00 | 0.00 | 5751202.42 | 0.00 | 17873359.52 | 0.378029E+10 | 0.00 | 0.56 |
November | 0.401233E+10 | 0.00 | 0.00 | 983257.33 | 0.00 | 0.238013E+09 | 0.104915E+10 | 0.00 | 0.40 |
December | 0.482015E+10 | 0.00 | 0.00 | 151062.30 | 0.00 | 0.887568E+09 | 0.208747E+09 | 0.00 | 0.39 |
Annual Sum or Average | 0.290458E+11 | 79768683.23 | 0.00 | 79658073.01 | 54733.20 | 0.268068E+10 | 0.370862E+11 | 0.00 | 0.64 |
Minimum of Months | 0.114955E+09 | 0.00 | 0.00 | 151062.30 | 0.00 | 0.00 | 0.208747E+09 | 0.00 | 0.39 |
Maximum of Months | 0.484975E+10 | 42695660.29 | 0.00 | 17034934.42 | 54733.20 | 0.887568E+09 | 0.555171E+10 | 0.00 | 1.08 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.405207E+10 | 0.00 | 0.00 | 10805.56 | 0.00 | 0.220904E+10 | 57406882.92 | 0.00 | 0.42 |
February | 0.388858E+10 | 0.00 | 0.00 | 45854.11 | 0.00 | 0.163852E+10 | 54199912.86 | 0.00 | 0.42 |
March | 0.398915E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171368E+10 | 0.00 | 0.00 | 0.43 |
April | 0.290164E+10 | 0.00 | 0.00 | 2843579.23 | 329145.92 | 0.312095E+09 | 0.150879E+10 | 0.00 | 0.43 |
May | 0.294727E+10 | 0.00 | 0.00 | 2428763.50 | 0.00 | 0.187509E+09 | 0.139367E+10 | 0.00 | 0.43 |
June | 0.124457E+10 | 15785472.76 | 0.00 | 5046257.26 | 0.00 | 4275332.15 | 0.217060E+10 | 0.00 | 0.43 |
July | 0.828880E+09 | 17161035.25 | 0.00 | 7228865.24 | 0.00 | 1357583.83 | 0.190518E+10 | 0.00 | 0.43 |
August | 0.653146E+09 | 161301.91 | 0.00 | 9605085.48 | 0.00 | 0.00 | 0.182659E+10 | 0.00 | 0.43 |
September | 0.106398E+10 | 2078.22 | 0.00 | 8698030.51 | 0.00 | 0.00 | 0.214716E+10 | 0.00 | 0.43 |
October | 0.318273E+10 | 0.00 | 0.00 | 2323375.56 | 0.00 | 0.409407E+09 | 0.115082E+10 | 0.00 | 0.42 |
November | 0.392337E+10 | 0.00 | 0.00 | 77215.83 | 0.00 | 0.120785E+10 | 0.127388E+09 | 0.00 | 0.42 |
December | 0.327109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295076E+10 | 0.00 | 0.00 | 0.42 |
Annual Sum or Average | 0.319465E+11 | 33109888.13 | 0.00 | 38307832.28 | 329145.92 | 0.106345E+11 | 0.123418E+11 | 0.00 | 0.43 |
Minimum of Months | 0.653146E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.42 |
Maximum of Months | 0.405207E+10 | 17161035.25 | 0.00 | 9605085.48 | 329145.92 | 0.295076E+10 | 0.217060E+10 | 0.00 | 0.43 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:49
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |