Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13
Tabular Output Report in Format: HTML
Building: RetailStandalone
Environment: RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190
Simulation Timestamp: 2020-06-03 19:13:29
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1143.57 | 498.51 | 498.51 |
Net Site Energy | 1143.57 | 498.51 | 498.51 |
Total Source Energy | 3268.30 | 1424.72 | 1424.72 |
Net Source Energy | 3268.30 | 1424.72 | 1424.72 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2293.99 |
Net Conditioned Building Area | 2293.99 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 78.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 334.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 59.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 146.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 19.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 91.29 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 973.92 | 169.65 | 0.00 | 0.00 | 0.00 | 134.99 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 78.36 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 219.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 334.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 59.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 195.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 146.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 19.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 91.29 | 0.00 | 0.00 | 0.00 | 134.99 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 171.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 159.41 | 73.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 93.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 424.55 | 73.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 171.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 159.41 | 73.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Other | 93.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 424.55 | 73.96 | 0.00 | 0.00 | 0.00 | 0.06 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 973.917 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 973.917 | 100.00 |
Total On-Site and Utility Electric Sources | 973.917 | 100.00 |
Total Electricity End Uses | 973.917 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | 0.00 |
Air to Air Heat Recovery for Cooling | 150.71 | 46.79 |
Air to Air Heat Recovery for Heating | 171.42 | 53.21 |
High-Temperature Geothermal* | 0.00 | 0.00 |
Solar Water Thermal | 0.00 | 0.00 |
Solar Air Thermal | 0.00 | 0.00 |
Total On-Site Thermal Sources | 322.13 | 100.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 134.99 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 134.99 | 100.00 |
Total Water End Uses | 134.99 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 907.67 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
| Meter |ZoneCoolingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneHeatingSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ZoneElectricSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |PeakSpaceGainsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |SpaceGainComponentsAtCoolingPeakMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |ComfortReportSimple55Monthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |OccupantComfortDataSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |DXReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowEnergyReportMonthly
| SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | POINT_OF_SALE_WALL_SOUTH_GLAZING | FRONT_RETAIL_WALL_SOUTH_GLAZING | FRONT_ENTRY_WALL_SOUTH_GLAZING |WindowZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |WindowEnergyZoneSummaryMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | FRONT_ENTRY UNIT HEATER COIL | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| FRONT_ENTRY UNIT HEATERFAN | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 |MechanicalVentilationLoadsMonthly
| BACK_SPACE | CORE_RETAIL | POINT_OF_SALE | FRONT_RETAIL | FRONT_ENTRY |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:13 |
RunPeriod | RUNPERIOD 1 |
Weather File | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
Latitude [deg] | 33.63 |
Longitude [deg] | -84.4 |
Elevation [m] | 308.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Above Ground Wall Area [m2] | 1177.02 | 330.83 | 257.68 | 330.83 | 257.68 |
Window Opening Area [m2] | 83.94 | 0.00 | 0.00 | 83.94 | 0.00 |
Gross Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Above Ground Window-Wall Ratio [%] | 7.13 | 0.00 | 0.00 | 25.37 | 0.00 |
Total | |
Gross Roof Area [m2] | 2293.99 |
Skylight Area [m2] | 23.78 |
Skylight-Roof Ratio [%] | 1.04 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
BACK_SPACE | 379.89 | Yes | Yes | 2317.33 | 1.00 | 416.17 | 0.00 | 0.00 | 0.00 | 6.8133 | 6.19 | 8.0700 |
CORE_RETAIL | 1600.48 | Yes | Yes | 9762.95 | 1.00 | 356.86 | 0.00 | 0.00 | 0.00 | 15.4032 | 6.19 | 3.2300 |
POINT_OF_SALE | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 15.4032 | 6.19 | 21.5200 |
FRONT_RETAIL | 150.81 | Yes | Yes | 919.94 | 1.00 | 189.80 | 0.00 | 38.05 | 38.05 | 15.4032 | 6.19 | 3.2300 |
FRONT_ENTRY | 12.00 | Yes | Yes | 73.20 | 1.00 | 24.38 | 0.00 | 7.83 | 7.83 | 8.7188 | 0.0000 | |
Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 13.9457 | 6.23 | 5.2170 | |||
Conditioned Total | 2293.99 | 13993.36 | 1177.02 | 0.00 | 83.94 | 83.94 | 13.9457 | 6.23 | 5.2170 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 07-JUL-15:50 | 12-FEB-09:09 | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 132814.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 41134.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 22946.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 7889.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 1406.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 84146.97 | 134676.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 132814.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 41134.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 22946.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 7889.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 1406.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 0.00 | 1862.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 84.95 | 0.00 | 0.00 | 0.00 |
Cooling | 694.19 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1058.38 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 189.03 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 618.06 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 463.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 60.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 98.96 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3084.40 | 183.90 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 37.03 | 0.00 | 0.00 | 0.00 |
Cooling | 302.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 461.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 82.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 202.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 26.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 43.14 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1344.55 | 80.17 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 37.03 | 0.00 | 0.00 | 0.00 |
Cooling | 302.61 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 461.37 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 82.40 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 269.43 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 202.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 26.51 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 43.14 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1344.55 | 80.17 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
BACK_SPACE DIRECT AIR | 1.91 |
CORE_RETAIL DIRECT AIR | 7.49 |
POINT_OF_SALE DIRECT AIR | 1.13 |
FRONT_RETAIL DIRECT AIR | 0.870621 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATER | 1.82 |
Design Size Maximum Flow Rate [m3/s] | |
FRONT_ENTRY UNIT HEATERFAN | 1.82 |
Design Size Nominal Capacity [W] | |
FRONT_ENTRY UNIT HEATER COIL | 40769.97 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | 49958.87 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | 227212.53 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | 30821.08 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | 25048.67 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC:1 | 1.91 | 1.91 | 1.91 | 1.91 | 1.93 | 1.93 | 1.00 | 0.993788 | 1.93 |
PSZ-AC:2 | 7.49 | 7.49 | 7.49 | 7.49 | 7.69 | 7.69 | 1.00 | 0.974011 | 7.69 |
PSZ-AC:3 | 1.13 | 1.13 | 1.13 | 1.13 | 1.13 | 1.13 | 1.00 | 1.00 | 1.13 |
PSZ-AC:4 | 0.870621 | 0.870621 | 0.870621 | 0.870621 | 0.870621 | 0.870621 | 1.00 | 1.00 | 0.870621 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC:1_OA_CONTROLLER | 1.93 | 0.231567 |
PSZ-AC:2_OA_CONTROLLER | 7.69 | 1.89 |
PSZ-AC:3_OA_CONTROLLER | 1.13 | 0.178111 |
PSZ-AC:4_OA_CONTROLLER | 0.870621 | 0.178111 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC:1_UNITARY_PACKAGE_DX | 1.93 | 1.93 | 1.93 | 1.27 | 36948.34 | 49958.87 | 40.00 | 1.00 |
PSZ-AC:2_UNITARY_PACKAGE_DX | 7.69 | 7.69 | 7.69 | 5.08 | 181403.78 | 227212.53 | 40.00 | 1.00 |
PSZ-AC:3_UNITARY_PACKAGE_DX | 1.13 | 1.13 | 1.13 | 0.745617 | 23447.54 | 30821.08 | 40.00 | 1.00 |
PSZ-AC:4_UNITARY_PACKAGE_DX | 0.870621 | 0.870621 | 0.870621 | 0.574610 | 19172.02 | 25048.67 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 1.93 | 0.962535 | 1.28 | 34520.25 | 36948.34 | 18474.17 | 18474.17 | 0.748091 | 0.748090 | 0.748090 | 0.748090 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 7.69 | 3.85 | 5.13 | 171984.10 | 181403.78 | 90701.89 | 90701.89 | 0.689019 | 0.689020 | 0.689020 | 0.689020 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 1.13 | 0.564860 | 0.753147 | 22007.81 | 23447.54 | 11723.77 | 11723.77 | 0.724228 | 0.724230 | 0.724230 | 0.724230 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 0.870620 | 0.435310 | 0.580413 | 18082.23 | 19172.02 | 9586.01 | 9586.01 | 0.707371 | 0.707370 | 0.707370 | 0.707370 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.93 | 2059.91 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | 7.69 | 12956.65 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | 1.13 | 1250.78 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.870621 | 963.92 |
Design Size Nominal Supply Air Flow Rate [m3/s] | |
PSZ-AC:2 OA HEAT RECOVERY | 1.89 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
BACK_SPACE_WALL_EAST | BACK_SPACE_WALL_EAST_ROLLDOOR | |
BACK_SPACE_WALL_NORTH | BACK_SPACE_WALL_NORTH_DOOR1 | BACK_SPACE_WALL_NORTH_DOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | |
BACK_SPACE_WALL_WEST | BACK_SPACE_WALL_WEST_ROLLDOOR | |
CORE_RETAIL_WALL_WEST_2 | CORE_RETAIL_WALL_WEST_2_DOOR3 | CORE_RETAIL_WALL_WEST_2_DOOR2 | CORE_RETAIL_WALL_WEST_2_DOOR1 | |
CORE_RETAIL_WALL_EAST_2 | CORE_RETAIL_WALL_EAST_2_DOOR1 | CORE_RETAIL_WALL_EAST_2_DOOR2 | CORE_RETAIL_WALL_EAST_2_DOOR3 | |
CORE_RETAIL_ROOF | SKYLIGHTS_R4C1 | SKYLIGHTS_R4C2 | SKYLIGHTS_R4C3 | SKYLIGHTS_R4C4 | SKYLIGHTS_R1C1 | SKYLIGHTS_R1C2 | SKYLIGHTS_R1C4 | SKYLIGHTS_R1C3 | SKYLIGHTS_R2C2 | SKYLIGHTS_R2C1 | SKYLIGHTS_R2C3 | SKYLIGHTS_R2C4 | SKYLIGHTS_R3C2 | SKYLIGHTS_R3C1 | SKYLIGHTS_R3C3 | SKYLIGHTS_R3C4 | |
POINT_OF_SALE_WALL_SOUTH | POINT_OF_SALE_WALL_SOUTH_GLAZING | |
FRONT_RETAIL_WALL_SOUTH | FRONT_RETAIL_WALL_SOUTH_GLAZING | |
FRONT_ENTRY_WALL_SOUTH | FRONT_ENTRY_WALL_SOUTH_GLAZING | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 11.90 | 7.70 | 4.00 | 7.90 | 13.80 | 17.20 | 20.80 | 24.80 | 26.10 | 26.50 | 22.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 | 33.63 | -84.43 | -5.00 | 308.00 | 97679 | 1.1610 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 16.60 | 22.50 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStandalone | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 5 | 73 | 32 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | BACK_SPACE | 0.0 | 0.00 | 35.27 | 0.00 | 27.14 | 38.77 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 35.27 | 42.27 | 0.00 | 6.10 | 6.10 | 2317.33 | TARP | TARP | 379.89 | 416.17 | 375.11 | 0.00 | 6 | 7 | 0 | Yes |
2 | CORE_RETAIL | 0.0 | 0.00 | 6.00 | 0.00 | 27.14 | 14.41 | 3.05 | 1 | 1 | 1 | 0.00 | 54.27 | 3.00 | 35.27 | 0.00 | 6.10 | 6.10 | 9762.95 | TARP | TARP | 1600.48 | 356.86 | 345.15 | 23.78 | 10 | 22 | 0 | Yes |
3 | POINT_OF_SALE | 0.0 | 0.00 | 0.00 | 0.00 | 12.57 | 3.00 | 3.05 | 1 | 1 | 1 | 0.00 | 25.14 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
4 | FRONT_RETAIL | 0.0 | 29.14 | 0.00 | 0.00 | 41.70 | 3.00 | 3.05 | 1 | 1 | 1 | 29.14 | 54.27 | 0.00 | 6.00 | 0.00 | 6.10 | 6.10 | 919.94 | TARP | TARP | 150.81 | 189.80 | 151.75 | 38.05 | 7 | 1 | 0 | Yes |
5 | FRONT_ENTRY | 0.0 | 25.14 | 0.00 | 0.00 | 27.14 | 1.50 | 3.05 | 1 | 1 | 1 | 25.14 | 29.14 | 0.00 | 3.00 | 0.00 | 6.10 | 6.10 | 73.20 | TARP | TARP | 12.00 | 24.38 | 16.55 | 7.83 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | BACK_SPACE | 379.89 | 61.3 | 6.193 | 0.161 | 6.813 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.883 | No |
2 | CORE_RETAIL | 1600.48 | 258.4 | 6.193 | 0.161 | 15.403 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 18.633 | No |
3 | POINT_OF_SALE | 150.81 | 24.4 | 6.193 | 0.161 | 15.403 | 21.520 | 0.000 | 0.000 | 0.000 | 0.000 | 36.923 | No |
4 | FRONT_RETAIL | 150.81 | 24.4 | 6.193 | 0.161 | 15.403 | 3.230 | 0.000 | 0.000 | 0.000 | 0.000 | 18.633 | No |
5 | FRONT_ENTRY | 12.00 | 0.0 | N/A | 0.000 | 8.719 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8.719 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | BACK_SPACE | BLDG_OCC_SCH | BACK_SPACE | 379.89 | 61.3 | 61.3 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 61 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | CORE_RETAIL | BLDG_OCC_SCH | CORE_RETAIL | 1600.48 | 258.4 | 258.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 258 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | POINT_OF_SALE | BLDG_OCC_SCH | POINT_OF_SALE | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | FRONT_RETAIL | BLDG_OCC_SCH | FRONT_RETAIL | 150.81 | 24.4 | 24.4 | 0.161 | 6.193 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | FRONT_ENTRY | BLDG_OCC_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.0 | 0.000 | N/A | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 0 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | BACK_SPACE_LIGHTS | BLDG_LIGHT_BACK_SCH | BACK_SPACE | 379.89 | 61.3 | 2588.290 | 6.813 | 42.195 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2588.290 |
2 | CORE_RETAIL_LIGHTS | BLDG_LIGHT_CORE_SCH | CORE_RETAIL | 1600.48 | 258.4 | 24652.487 | 15.403 | 95.392 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 24652.487 |
3 | POINT_OF_SALE_LIGHTS | BLDG_LIGHT_SCH | POINT_OF_SALE | 150.81 | 24.4 | 2322.950 | 15.403 | 95.392 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2322.950 |
4 | FRONT_RETAIL_LIGHTS | BLDG_LIGHT_FRONT_SCH | FRONT_RETAIL | 150.81 | 24.4 | 2322.950 | 15.403 | 95.392 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2322.950 |
5 | FRONT_ENTRY_LIGHTS | BLDG_LIGHT_ENTRY_SCH | FRONT_ENTRY | 12.00 | 0.0 | 104.625 | 8.719 | N/A | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 104.625 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | BACK_SPACE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | BACK_SPACE | 379.89 | 61.3 | 3065.712 | 8.070 | 49.978 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3065.712 |
2 | CORE_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_RETAIL | 1600.48 | 258.4 | 5169.560 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 5169.560 |
3 | POINT_OF_SALE_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | POINT_OF_SALE | 150.81 | 24.4 | 3245.431 | 21.520 | 133.273 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 3245.431 |
4 | FRONT_RETAIL_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | FRONT_RETAIL | 150.81 | 24.4 | 487.116 | 3.230 | 20.003 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 487.116 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 3.464 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | OVERHEAD DOOR_CON | 2 | 1 | 1 | 0.167 | 1.195 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
3 | INTERIORFURNISHINGS | 3 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 8 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | NONRES_ROOF | 18 | 3 | 3 | 0.167 | 0.2284 | 0.750 | 0.900 | 0.450 | 0.700 | Rough |
6 | NONRES_EXT_WALL | 21 | 3 | 9 | 0.167 | 0.7800 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | BACK_SPACE_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.2354 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | CORE_RETAIL_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.4655E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | POINT_OF_SALE_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | FRONT_RETAIL_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.2719 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | FRONT_ENTRY_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.4506 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2887 |
2 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.8365 |
3 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
7 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | 200MM NORMALWEIGHT CONCRETE WALL | 0.2032 | 2.310 | 2322.000 | 832.000 | 0.8797E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.115 |
11 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.172 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 21.40 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 3.601 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 2.142 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 3.4637443 | 3.4637443 | 3.4637443 | |
3 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
4 | 0 | 1.1954460 | 1.1954460 | 1.1954460 | |
5 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
6 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
7 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
8 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
9 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
10 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
11 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
12 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
13 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
14 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
15 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
16 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
17 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
18 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
19 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
20 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
21 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
22 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
23 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
24 | 9 | -0.41768822E-14 | 0.27520919E-16 | -0.15672466E-09 | 0.83927561E-16 |
25 | 8 | 0.22856702E-07 | 0.10578700E-12 | 0.38803401E-03 | -0.25988854E-09 |
26 | 7 | -0.12546900E-01 | 0.54357740E-08 | -0.23525379E-01 | 0.14266284E-03 |
27 | 6 | 0.41364683 | 0.18861797E-05 | 0.47915075 | -0.48455579E-02 |
28 | 5 | -5.2715232 | 0.70271773E-04 | -4.4954566 | 0.64187715E-01 |
29 | 4 | 33.360936 | 0.57369956E-03 | 21.652120 | -0.42687724 |
30 | 3 | -111.98802 | 0.12481219E-02 | -56.042688 | 1.5262008 |
31 | 2 | 197.88617 | 0.70096321E-03 | 78.258916 | -2.9127067 |
32 | 1 | -171.44340 | 0.74721452E-04 | -55.366563 | 2.7504751 |
33 | 0 | 57.057407 | 0.42462867E-06 | 15.540328 | |
34 | 7 | -0.17867606E-08 | -0.41848128E-15 | 0.59564440E-14 | -0.80268503E-16 |
35 | 6 | 0.65885627E-05 | 0.45121803E-08 | 0.31870471E-02 | -0.26735622E-04 |
36 | 5 | -0.47407468E-03 | 0.26731137E-05 | -0.22356413 | 0.19547341E-02 |
37 | 4 | 0.10906669E-01 | 0.12168607E-03 | 4.8268734 | -0.45239294E-01 |
38 | 3 | -0.95781928E-01 | 0.96775432E-03 | -38.006321 | 0.39848689 |
39 | 2 | 0.34010998 | 0.16100142E-02 | 116.45457 | -1.4175463 |
40 | 1 | -0.49090295 | 0.49061009E-03 | -143.89001 | 2.0487556 |
41 | 0 | 0.23934032 | 0.11861159E-04 | 60.838472 | |
42 | 7 | -0.92098544E-08 | 0.58605081E-15 | -0.29904982E-14 | 0.25019681E-16 |
43 | 6 | 0.19387148E-05 | 0.91388609E-09 | 0.32017682E-02 | -0.26859115E-04 |
44 | 5 | -0.10799279E-03 | 0.53275402E-06 | -0.22440051 | 0.19621166E-02 |
45 | 4 | 0.22736042E-02 | 0.24052495E-04 | 4.8407977 | -0.45373149E-01 |
46 | 3 | -0.19287081E-01 | 0.18995237E-03 | -38.084949 | 0.39935605 |
47 | 2 | 0.67516478E-01 | 0.31394945E-03 | 116.60756 | -1.4195928 |
48 | 1 | -0.96817688E-01 | 0.94848058E-04 | -143.98006 | 2.0502357 |
49 | 0 | 0.47046370E-01 | 0.22824214E-05 | 60.838472 | |
50 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
51 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
52 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
53 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
54 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
55 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
56 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
57 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
58 | 7 | -0.15410587E-08 | -0.27131508E-15 | 0.13739895E-13 | -0.20869099E-15 |
59 | 6 | 0.75948721E-05 | 0.52202150E-08 | 0.31841660E-02 | -0.26711453E-04 |
60 | 5 | -0.54825752E-03 | 0.30939483E-05 | -0.22340036 | 0.19532886E-02 |
61 | 4 | 0.12624073E-01 | 0.14086823E-03 | 4.8241453 | -0.45213070E-01 |
62 | 3 | -0.11089483 | 0.11205317E-02 | -37.990908 | 0.39831653 |
63 | 2 | 0.39381345 | 0.18644394E-02 | 116.42457 | -1.4171450 |
64 | 1 | -0.56844024 | 0.56830838E-03 | -143.87235 | 2.0484654 |
65 | 0 | 0.27714917 | 0.13715070E-04 | 60.838472 | |
66 | 7 | -0.91256693E-09 | -0.65654920E-16 | 0.14763662E-14 | 0.25811017E-17 |
67 | 6 | 0.12659591E-04 | 0.87293215E-08 | 0.31698558E-02 | -0.26591407E-04 |
68 | 5 | -0.91895148E-03 | 0.51830142E-05 | -0.22258679 | 0.19461077E-02 |
69 | 4 | 0.21183618E-01 | 0.23613386E-03 | 4.8105909 | -0.45082779E-01 |
70 | 3 | -0.18612912 | 0.18798277E-02 | -37.914317 | 0.39746999 |
71 | 2 | 0.66101200 | 0.31293459E-02 | 116.27548 | -1.4151508 |
72 | 1 | -0.95411819 | 0.95507326E-03 | -143.78458 | 2.0470226 |
73 | 0 | 0.46518638 | 0.22828278E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.46_SHGC_0.25 | 30 | 1 | VerySmooth | 2.615 | 0.252 | 0.162 | 0.251 |
2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 31 | 1 | VerySmooth | 5.108 | 0.600 | 0.461 | 0.601 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.53892E-002 | 0.16139 | 0.61607 | 0.61607 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 0.12001 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.46039 | 0.10300 | 0.10300 | 0.60000 | 0.13030 | 0.15164 | 0.00000 | 0.84000 | 0.84000 | 6.93520E-002 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Zone Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Zones | |
1 | CORE_RETAIL | 16 | 0 |
Zone Name | Number of Adjacent Zones with Windows | Adjacent Zone Names - 1st 100 (max) | |
1 | CORE_RETAIL | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK | 0.1514 | 11722.8 | 0.731 | 0.1913 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | BACK_SPACE_WALL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
3 | BACK_SPACE_WALL_NORTH | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
4 | BACK_SPACE_WALL_NORTH_DOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | 0 | 330.83 | 149.77 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
9 | BACK_SPACE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
11 | BACK_SPACE_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
12 | BACK_SPACE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
13 | BACK_SPACE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
14 | BACK_SPACE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 68.27 | 12.40 | 0.00 | 0 | No | No |
15 | CORE_RETAIL_WALL_SOUTH_3 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
16 | CORE_RETAIL_WALL_SOUTH_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
17 | CORE_RETAIL_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
18 | CORE_RETAIL_WALL_SOUTH_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
19 | CORE_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
20 | CORE_RETAIL_WALL_WEST_2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
24 | CORE_RETAIL_WALL_EAST_2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 4 | No | No |
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
28 | CORE_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
29 | CORE_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
30 | CORE_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
31 | SKYLIGHTS_R4C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
32 | SKYLIGHTS_R4C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
33 | SKYLIGHTS_R4C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
34 | SKYLIGHTS_R4C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
35 | SKYLIGHTS_R1C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
36 | SKYLIGHTS_R1C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
37 | SKYLIGHTS_R1C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
38 | SKYLIGHTS_R1C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
39 | SKYLIGHTS_R2C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
40 | SKYLIGHTS_R2C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
41 | SKYLIGHTS_R2C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
42 | SKYLIGHTS_R2C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
43 | SKYLIGHTS_R3C2 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
44 | SKYLIGHTS_R3C1 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
45 | SKYLIGHTS_R3C3 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
46 | SKYLIGHTS_R3C4 | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 2 | No | No |
47 | CORE_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 58.54 | 36.99 | 6.66E-002 | 0 | No | No |
48 | POINT_OF_SALE_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
50 | POINT_OF_SALE_WALL_EAST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
51 | POINT_OF_SALE_WALL_WEST | 0 | 257.68 | 96.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
52 | POINT_OF_SALE_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
53 | POINT_OF_SALE_WALL_EAST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
54 | POINT_OF_SALE_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
55 | POINT_OF_SALE_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
56 | POINT_OF_SALE_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
57 | FRONT_RETAIL_WALLL_EAST | 0 | 257.68 | 149.77 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
58 | FRONT_RETAIL_WALL_WEST_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
59 | FRONT_RETAIL_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
60 | FRONT_RETAIL_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 4 | No | No |
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 1 | No | No |
62 | FRONT_RETAIL_WALL_WEST_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
63 | FRONT_RETAIL_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
64 | FRONT_RETAIL_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
65 | FRONT_RETAIL_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 31.14 | 9.69 | 0.20 | 0 | No | No |
66 | FRONT_ENTRY_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
67 | FRONT_ENTRY_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
68 | FRONT_ENTRY_WALL_SOUTH | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 4 | No | No |
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | 0 | 330.83 | 120.73 | 6.10 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 1 | No | No |
70 | FRONT_ENTRY_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
71 | FRONT_ENTRY_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
72 | FRONT_ENTRY_ROOF | 0 | 2293.99 | 205.08 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
73 | FRONT_ENTRY_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 6.10 | 4.00 | 3.43 | 0.32 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | BACK_SPACE_INFILTRATION | INFIL_SCH_PNNL | BACK_SPACE | 379.89 | 61.3 | 0.249 | 6.557E-004 | 2.976E-004 | 0.387 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | CORE_RETAIL_INFILTRATION | INFIL_SCH_PNNL | CORE_RETAIL | 1600.48 | 258.4 | 0.204 | 1.274E-004 | 1.036E-004 | 7.518E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | POINT_OF_SALE_INFILTRATION | INFIL_SCH_PNNL | POINT_OF_SALE | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | FRONT_RETAIL_INFILTRATION | INFIL_SCH_PNNL | FRONT_RETAIL | 150.81 | 24.4 | 0.108 | 7.158E-004 | 3.169E-004 | 0.422 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | FRONT_ENTRY_INFILTRATION | INFIL_SCH_PNNL | FRONT_ENTRY | 12.00 | 0.0 | 1.387E-002 | 1.156E-003 | 3.812E-004 | 0.682 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | FRONT_ENTRY_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | FRONT_ENTRY | 12.00 | 0.0 | 0.937 | 7.811E-002 | 2.576E-002 | 46.096 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | BACK_SPACE | Mixing/Well-Stirred |
2 | CORE_RETAIL | Mixing/Well-Stirred |
3 | POINT_OF_SALE | Mixing/Well-Stirred |
4 | FRONT_RETAIL | Mixing/Well-Stirred |
5 | FRONT_ENTRY | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone BACK_SPACE | 1.2000 |
3 | Zone CORE_RETAIL | 1.2000 |
4 | Zone POINT_OF_SALE | 1.2000 |
5 | Zone FRONT_RETAIL | 1.2000 |
6 | Zone FRONT_ENTRY | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | BACK_SPACE | Cooling | 21760.92583 | 26113.11100 | 1.59426 | 1.91311 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 27.37000 | 1.44457E-002 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
2 | BACK_SPACE | Heating | 21381.22817 | 25657.47380 | 0.93194 | 1.11832 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 379.89000 | 61.34184 | 0.23157 | 0.00000 |
3 | CORE_RETAIL | Cooling | 85422.68281 | 102507.21937 | 6.24236 | 7.49083 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 27.37000 | 1.44457E-002 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
4 | CORE_RETAIL | Heating | 53882.88967 | 64659.46760 | 2.31560 | 2.77872 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 1600.48290 | 258.43418 | 1.89021 | 0.00000 |
5 | POINT_OF_SALE | Cooling | 12709.17568 | 15251.01082 | 0.94144 | 1.12972 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 27.37000 | 1.44457E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
6 | POINT_OF_SALE | Heating | 10638.99994 | 12766.79993 | 0.46579 | 0.55895 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
7 | FRONT_RETAIL | Cooling | 9861.78227 | 11834.13872 | 0.72552 | 0.87062 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 27.37000 | 1.44457E-002 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
8 | FRONT_RETAIL | Heating | 10642.08149 | 12770.49779 | 0.46593 | 0.55912 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -6.30000 | 2.29779E-003 | 150.81000 | 24.35169 | 0.17811 | 0.00000 |
9 | FRONT_ENTRY | Cooling | 0.00000 | 0.00000 | 0.00000 | 1.41723E-002 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.40000 | 1.44457E-002 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 | |
10 | FRONT_ENTRY | Heating | 33944.25650 | 40733.10780 | 1.51274 | 1.81529 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -6.30000 | 2.29779E-003 | 12.00000 | 0.00000 | 1.41723E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC:1 | Cooling | Sensible | 25999.20 | 1.92507 | 1.92507 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-AC:1 | Heating | Sensible | 32257.56 | 1.11832 | 1.11832 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
3 | PSZ-AC:2 | Cooling | Sensible | 113598.77 | 7.69071 | 7.69071 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-AC:2 | Heating | Sensible | 121947.25 | 2.77872 | 2.77872 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
5 | PSZ-AC:3 | Cooling | Sensible | 16009.89 | 1.12972 | 1.12972 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
6 | PSZ-AC:3 | Heating | Sensible | 18105.15 | 0.55895 | 0.55895 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
7 | PSZ-AC:4 | Cooling | Sensible | 13144.68 | 0.87062 | 0.87062 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
8 | PSZ-AC:4 | Heating | Sensible | 18108.82 | 0.55912 | 0.55912 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | BACK_SPACE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.91311 |
2 | AirTerminal:SingleDuct:Uncontrolled | CORE_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 7.49083 |
3 | AirTerminal:SingleDuct:Uncontrolled | POINT_OF_SALE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.12972 |
4 | AirTerminal:SingleDuct:Uncontrolled | FRONT_RETAIL DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.87062 |
5 | ZoneHVAC:UnitHeater | FRONT_ENTRY UNIT HEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 1.81529 |
6 | Fan:ConstantVolume | FRONT_ENTRY UNIT HEATERFAN | Design Size Maximum Flow Rate [m3/s] | 1.81529 |
7 | Coil:Heating:Fuel | FRONT_ENTRY UNIT HEATER COIL | Design Size Nominal Capacity [W] | 40769.97198 |
8 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.91311 |
9 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.91311 |
10 | AirLoopHVAC | PSZ-AC:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.91311 |
11 | AirLoopHVAC | PSZ-AC:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.91311 |
12 | AirLoopHVAC | PSZ-AC:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.92507 |
13 | AirLoopHVAC | PSZ-AC:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.92507 |
14 | AirLoopHVAC | PSZ-AC:1 | User Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-AC:1 | Calculated Heating Air Flow Ratio [] | 0.99379 |
16 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 7.49083 |
17 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 7.49083 |
18 | AirLoopHVAC | PSZ-AC:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 7.49083 |
19 | AirLoopHVAC | PSZ-AC:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 7.49083 |
20 | AirLoopHVAC | PSZ-AC:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 7.69071 |
21 | AirLoopHVAC | PSZ-AC:2 | Adjusted Main Design Air Flow Rate [m3/s] | 7.69071 |
22 | AirLoopHVAC | PSZ-AC:2 | User Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-AC:2 | Calculated Heating Air Flow Ratio [] | 0.97401 |
24 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.12972 |
25 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.12972 |
26 | AirLoopHVAC | PSZ-AC:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.12972 |
27 | AirLoopHVAC | PSZ-AC:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.12972 |
28 | AirLoopHVAC | PSZ-AC:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.12972 |
29 | AirLoopHVAC | PSZ-AC:3 | Adjusted Main Design Air Flow Rate [m3/s] | 1.12972 |
30 | AirLoopHVAC | PSZ-AC:3 | User Heating Air Flow Ratio [] | 1.00000 |
31 | AirLoopHVAC | PSZ-AC:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
32 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.87062 |
33 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.87062 |
34 | AirLoopHVAC | PSZ-AC:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.87062 |
35 | AirLoopHVAC | PSZ-AC:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.87062 |
36 | AirLoopHVAC | PSZ-AC:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.87062 |
37 | AirLoopHVAC | PSZ-AC:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.87062 |
38 | AirLoopHVAC | PSZ-AC:4 | User Heating Air Flow Ratio [] | 1.00000 |
39 | AirLoopHVAC | PSZ-AC:4 | Calculated Heating Air Flow Ratio [] | 1.00000 |
40 | AirLoopHVAC | PSZ-AC:1 | Design Supply Air Flow Rate [m3/s] | 1.92507 |
41 | AirLoopHVAC | PSZ-AC:2 | Design Supply Air Flow Rate [m3/s] | 7.69071 |
42 | AirLoopHVAC | PSZ-AC:3 | Design Supply Air Flow Rate [m3/s] | 1.12972 |
43 | AirLoopHVAC | PSZ-AC:4 | Design Supply Air Flow Rate [m3/s] | 0.87062 |
44 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.92507 |
45 | Controller:OutdoorAir | PSZ-AC:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.23157 |
46 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.92507 |
47 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.92507 |
48 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.92507 |
49 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.27054 |
50 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.92507 |
51 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.96254 |
52 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.28338 |
53 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 34520.24697 |
54 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 36948.34000 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 18474.17000 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 18474.17000 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.74809 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.74809 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.74809 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.74809 |
61 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 36948.34000 |
62 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 49958.86587 |
63 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
64 | AirLoopHVAC:UnitarySystem | PSZ-AC:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
65 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.92507 |
66 | Fan:SystemModel | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 2059.91291 |
67 | Coil:Heating:Fuel | PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 49958.86587 |
68 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 7.69071 |
69 | Controller:OutdoorAir | PSZ-AC:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 1.89021 |
70 | HeatExchanger:AirToAir:SensibleAndLatent | PSZ-AC:2 OA HEAT RECOVERY | Design Size Nominal Supply Air Flow Rate [m3/s] | 1.89021 |
71 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 7.69071 |
72 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 7.69071 |
73 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 7.69071 |
74 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 5.07587 |
75 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 7.69071 |
76 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 3.84536 |
77 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 5.12714 |
78 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 171984.10405 |
79 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 181403.78000 |
80 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 90701.89000 |
81 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 90701.89000 |
82 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68902 |
83 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68902 |
84 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68902 |
85 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68902 |
86 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 181403.78000 |
87 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 227212.53128 |
88 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
89 | AirLoopHVAC:UnitarySystem | PSZ-AC:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
90 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 7.69071 |
91 | Fan:SystemModel | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 12956.65169 |
92 | Coil:Heating:Fuel | PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 227212.53128 |
93 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.12972 |
94 | Controller:OutdoorAir | PSZ-AC:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
95 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.12972 |
96 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.12972 |
97 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.12972 |
98 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.74562 |
99 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.12972 |
100 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.56486 |
101 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.75315 |
102 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 22007.80808 |
103 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 23447.54000 |
104 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 11723.77000 |
105 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 11723.77000 |
106 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.72423 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.72423 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.72423 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.72423 |
110 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 23447.54000 |
111 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 30821.08206 |
112 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
113 | AirLoopHVAC:UnitarySystem | PSZ-AC:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
114 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.12972 |
115 | Fan:SystemModel | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1250.78270 |
116 | Coil:Heating:Fuel | PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 30821.08206 |
117 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.87062 |
118 | Controller:OutdoorAir | PSZ-AC:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.17811 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.87062 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.87062 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.87062 |
122 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.57461 |
123 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.87062 |
124 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.43531 |
125 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.58041 |
126 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 18082.23068 |
127 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 19172.02000 |
128 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 9586.01000 |
129 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 9586.01000 |
130 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.70737 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.70737 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.70737 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.70737 |
134 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 19172.02000 |
135 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25048.67292 |
136 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
137 | AirLoopHVAC:UnitarySystem | PSZ-AC:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
138 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.87062 |
139 | Fan:SystemModel | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 963.91579 |
140 | Coil:Heating:Fuel | PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25048.67292 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 35436.5 | 11.44 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 175342.5 | 12.96 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 22559.2 | 120.05 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 18486.7 | 159.71 |
Zone Name | # Surfaces | |
1 | BACK_SPACE | 14 |
2 | CORE_RETAIL | 33 |
3 | POINT_OF_SALE | 9 |
4 | FRONT_RETAIL | 9 |
5 | FRONT_ENTRY | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | BACK_SPACE_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 35.24 | 42.67 | 35.24 | 90.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | BACK_SPACE_WALL_EAST_ROLLDOOR | Door | BACK_SPACE_WALL_EAST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 90.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
3 | BACK_SPACE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 304.63 | 330.83 | 304.63 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | BACK_SPACE_WALL_NORTH_DOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | BACK_SPACE_WALL_NORTH_DOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
6 | BACK_SPACE_WALL_NORTH_ROLLDOOR1 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
7 | BACK_SPACE_WALL_NORTH_ROLLDOOR2 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
8 | BACK_SPACE_WALL_NORTH_ROLLDOOR3 | Door | BACK_SPACE_WALL_NORTH | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 0.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
9 | BACK_SPACE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 35.24 | 42.67 | 35.24 | 270.00 | 90.00 | 7.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | BACK_SPACE_WALL_WEST_ROLLDOOR | Door | BACK_SPACE_WALL_WEST | CTF - ConductionTransferFunction | OVERHEAD DOOR_CON | 1.195 | 1.195 | 7.43 | 7.43 | 7.43 | 270.00 | 90.00 | 3.05 | 2.44 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
11 | BACK_SPACE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 180.00 | 90.00 | 54.27 | 6.10 | 0.00 | CORE_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | BACK_SPACE_FLOOR | Floor | CTF - ConductionTransferFunction | BACK_SPACE_FLOOR_FFACTOR | 0.235 | 0.223 | 379.89 | 379.89 | 379.89 | 90.00 | 180.00 | 7.00 | 54.27 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | BACK_SPACE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 379.89 | 379.89 | 379.89 | 90.00 | 0.00 | 7.00 | 54.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
14 | BACK_SPACE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 759.78 | 759.78 | 759.78 | 0.00 | 90.00 | 759.78 | 1.00 | 0.00 | BACK_SPACE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
15 | CORE_RETAIL_WALL_SOUTH_3 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | FRONT_RETAIL_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
16 | CORE_RETAIL_WALL_SOUTH_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | POINT_OF_SALE_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | CORE_RETAIL_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
18 | CORE_RETAIL_WALL_SOUTH_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | CORE_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 330.83 | 330.83 | 330.83 | 0.00 | 90.00 | 54.27 | 6.10 | 0.00 | BACK_SPACE_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | CORE_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 172.58 | 178.43 | 172.58 | 270.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | CORE_RETAIL_WALL_WEST_2_DOOR3 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
22 | CORE_RETAIL_WALL_WEST_2_DOOR2 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | CORE_RETAIL_WALL_WEST_2_DOOR1 | Door | CORE_RETAIL_WALL_WEST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
24 | CORE_RETAIL_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 172.58 | 178.43 | 172.58 | 90.00 | 90.00 | 29.27 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
25 | CORE_RETAIL_WALL_EAST_2_DOOR1 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
26 | CORE_RETAIL_WALL_EAST_2_DOOR2 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
27 | CORE_RETAIL_WALL_EAST_2_DOOR3 | Door | CORE_RETAIL_WALL_EAST_2 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 3.464 | 3.464 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
28 | CORE_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
29 | CORE_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_RETAIL_FLOOR_FFACTOR | 4.655E-002 | 4.603E-002 | 1600.48 | 1600.48 | 1600.48 | 0.00 | 180.00 | 40.01 | 40.01 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 8 | ||
30 | CORE_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 1576.70 | 1600.48 | 1576.70 | 180.00 | 0.00 | 40.01 | 40.01 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 8 | ||
31 | SKYLIGHTS_R4C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
32 | SKYLIGHTS_R4C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
33 | SKYLIGHTS_R4C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
34 | SKYLIGHTS_R4C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
35 | SKYLIGHTS_R1C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
36 | SKYLIGHTS_R1C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
37 | SKYLIGHTS_R1C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
38 | SKYLIGHTS_R1C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
39 | SKYLIGHTS_R2C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
40 | SKYLIGHTS_R2C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
41 | SKYLIGHTS_R2C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
42 | SKYLIGHTS_R2C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
43 | SKYLIGHTS_R3C2 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 |
44 | SKYLIGHTS_R3C1 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 1.11E-016 | 1.00 | 4 |
45 | SKYLIGHTS_R3C3 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
46 | SKYLIGHTS_R3C4 | Window | CORE_RETAIL_ROOF | Window5 Detailed Fenestration | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | N/A | 5.108 | No | 1.49 | 1.49 | 1.49 | 180.00 | 0.00 | 1.22 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 4.44E-016 | 1.00 | 4 |
47 | CORE_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 3200.97 | 3200.97 | 3200.97 | 0.00 | 90.00 | 3200.97 | 1.00 | 0.00 | CORE_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
48 | POINT_OF_SALE_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | POINT_OF_SALE_WALL_SOUTH_GLAZING | Window | POINT_OF_SALE_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
50 | POINT_OF_SALE_WALL_EAST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
51 | POINT_OF_SALE_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 36.58 | 36.58 | 36.58 | 270.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
52 | POINT_OF_SALE_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
53 | POINT_OF_SALE_WALL_EAST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | POINT_OF_SALE_FLOOR | Floor | CTF - ConductionTransferFunction | POINT_OF_SALE_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 180.00 | 180.00 | 25.14 | 6.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
55 | POINT_OF_SALE_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 150.81 | 150.81 | 150.81 | 180.00 | 0.00 | 25.14 | 6.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
56 | POINT_OF_SALE_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | POINT_OF_SALE_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
57 | FRONT_RETAIL_WALLL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 36.58 | 36.58 | 36.58 | 90.00 | 90.00 | 6.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
58 | FRONT_RETAIL_WALL_WEST_1 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_ENTRY_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
59 | FRONT_RETAIL_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 153.22 | 153.22 | 153.22 | 0.00 | 90.00 | 25.14 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_3 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
60 | FRONT_RETAIL_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 115.17 | 153.22 | 115.17 | 180.00 | 90.00 | 25.14 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | FRONT_RETAIL_WALL_SOUTH_GLAZING | Window | FRONT_RETAIL_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 38.05 | 38.05 | 38.05 | 180.00 | 90.00 | 25.04 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | FRONT_RETAIL_WALL_WEST_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | FRONT_RETAIL_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_RETAIL_FLOOR_FFACTOR | 0.272 | 0.255 | 150.81 | 150.81 | 150.81 | 90.00 | 180.00 | 6.00 | 25.14 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
64 | FRONT_RETAIL_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 150.81 | 150.81 | 150.81 | 90.00 | 0.00 | 6.00 | 25.14 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
65 | FRONT_RETAIL_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 301.62 | 301.62 | 301.62 | 0.00 | 90.00 | 301.62 | 1.00 | 0.00 | FRONT_RETAIL_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
66 | FRONT_ENTRY_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 90.00 | 90.00 | 3.00 | 6.10 | 0.00 | FRONT_RETAIL_WALL_WEST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
67 | FRONT_ENTRY_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 24.38 | 24.38 | 24.38 | 0.00 | 90.00 | 4.00 | 6.10 | 0.00 | CORE_RETAIL_WALL_SOUTH_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
68 | FRONT_ENTRY_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.780 | 0.698 | 16.55 | 24.38 | 16.55 | 180.00 | 90.00 | 4.00 | 6.10 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | FRONT_ENTRY_WALL_SOUTH_GLAZING | Window | FRONT_ENTRY_WALL_SOUTH | Window5 Detailed Fenestration | NONRESWINDOW_U_0.46_SHGC_0.25 | N/A | 2.615 | No | 7.83 | 7.83 | 7.83 | 180.00 | 90.00 | 3.00 | 2.61 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | FRONT_ENTRY_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 18.29 | 18.29 | 18.29 | 270.00 | 90.00 | 3.00 | 6.10 | 0.00 | POINT_OF_SALE_WALL_EAST_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | FRONT_ENTRY_FLOOR | Floor | CTF - ConductionTransferFunction | FRONT_ENTRY_FLOOR_FFACTOR | 0.451 | 0.406 | 12.00 | 12.00 | 12.00 | 180.00 | 180.00 | 4.00 | 3.00 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
72 | FRONT_ENTRY_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 12.00 | 12.00 | 12.00 | 180.00 | 0.00 | 4.00 | 3.00 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
73 | FRONT_ENTRY_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 24.00 | 24.00 | 24.00 | 0.00 | 90.00 | 24.00 | 1.00 | 0.00 | FRONT_ENTRY_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 13 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | BACK_SPACE | RunPeriod: RUNPERIOD 1 | 4.3071009773E-002 | 0.1678620848 | Pass | Pass | 0.2170956048 | 0.7302422755 | Pass | Pass |
2 | CORE_RETAIL | RunPeriod: RUNPERIOD 1 | 4.0640081890E-002 | 8.1968777855E-002 | Pass | Pass | 0.3704936275 | 1.6840241176 | Pass | Pass |
3 | POINT_OF_SALE | RunPeriod: RUNPERIOD 1 | 5.4675993789E-002 | 0.1958207892 | Pass | Pass | 0.1989740221 | 0.6318524384 | Pass | Pass |
4 | FRONT_RETAIL | RunPeriod: RUNPERIOD 1 | 5.0641158548E-002 | 0.1985879343 | Pass | Pass | 0.2652993997 | 0.9827005769 | Pass | Pass |
5 | FRONT_ENTRY | RunPeriod: RUNPERIOD 1 | 0.1276230921 | 0.4190226710 | Pass | Pass | 7.2461154920E-002 | 0.5140901365 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | -6.30 | 0.00 | -6.30 | Wetbulb [C] | 5.30 | 320.00 |
ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 34.40 | 9.50 | 23.50 | Wetbulb [C] | 4.00 | 300.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
BACK_SPACE_WALL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 42.67 | 35.24 | 90.00 | 90.00 | E |
BACK_SPACE_WALL_NORTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 330.83 | 304.63 | 0.00 | 90.00 | N |
BACK_SPACE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 42.67 | 35.24 | 270.00 | 90.00 | W |
BACK_SPACE_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 379.89 | 379.89 | 90.00 | 0.00 | |
CORE_RETAIL_WALL_WEST_2 | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 178.43 | 172.58 | 270.00 | 90.00 | W |
CORE_RETAIL_WALL_EAST_2 | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 178.43 | 172.58 | 90.00 | 90.00 | E |
CORE_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 1600.48 | 1576.70 | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 153.22 | 115.17 | 180.00 | 90.00 | S |
POINT_OF_SALE_WALL_WEST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 36.58 | 36.58 | 270.00 | 90.00 | W |
POINT_OF_SALE_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 150.81 | 150.81 | 180.00 | 0.00 | |
FRONT_RETAIL_WALLL_EAST | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 36.58 | 36.58 | 90.00 | 90.00 | E |
FRONT_RETAIL_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 153.22 | 115.17 | 180.00 | 90.00 | S |
FRONT_RETAIL_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 150.81 | 150.81 | 90.00 | 0.00 | |
FRONT_ENTRY_WALL_SOUTH | NONRES_EXT_WALL | 0.30 | 0.698 | 0.780 | 24.38 | 16.55 | 180.00 | 90.00 | S |
FRONT_ENTRY_ROOF | NONRES_ROOF | 0.55 | 0.221 | 0.228 | 12.00 | 12.00 | 180.00 | 0.00 | |
BACK_SPACE_FLOOR | BACK_SPACE_FLOOR_FFACTOR | 1.00 | 0.235 | 379.89 | 379.89 | 90.00 | 180.00 | ||
CORE_RETAIL_FLOOR | CORE_RETAIL_FLOOR_FFACTOR | 1.00 | 0.047 | 1600.48 | 1600.48 | 0.00 | 180.00 | ||
POINT_OF_SALE_FLOOR | POINT_OF_SALE_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 180.00 | 180.00 | ||
FRONT_RETAIL_FLOOR | FRONT_RETAIL_FLOOR_FFACTOR | 1.00 | 0.272 | 150.81 | 150.81 | 90.00 | 180.00 | ||
FRONT_ENTRY_FLOOR | FRONT_ENTRY_FLOOR_FFACTOR | 1.00 | 0.451 | 12.00 | 12.00 | 180.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
SKYLIGHTS_R4C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R4C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R1C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R2C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C2 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C1 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C3 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
SKYLIGHTS_R3C4 | NONRESSKYLIGHT_U_0.9_SHGC_0.6 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 5.108 | 0.600 | 0.601 | 0.000 | 0.000 | No | CORE_RETAIL_ROOF | 180.00 | 0.00 | |
POINT_OF_SALE_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.46_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.615 | 0.252 | 0.251 | No | POINT_OF_SALE_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_RETAIL_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.46_SHGC_0.25 | 38.05 | 0.00 | 0.00 | 38.05 | 38.05 | 2.615 | 0.252 | 0.251 | No | FRONT_RETAIL_WALL_SOUTH | 180.00 | 90.00 | S | ||
FRONT_ENTRY_WALL_SOUTH_GLAZING | NONRESWINDOW_U_0.46_SHGC_0.25 | 7.83 | 0.00 | 0.00 | 7.83 | 7.83 | 2.615 | 0.252 | 0.251 | No | FRONT_ENTRY_WALL_SOUTH | 180.00 | 90.00 | S | ||
Total or Average | 107.72 | 3.165 | 0.329 | 0.328 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 107.72 | 3.165 | 0.329 | 0.328 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
BACK_SPACE_WALL_EAST_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_EAST |
BACK_SPACE_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR1 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR2 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_NORTH_ROLLDOOR3 | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_NORTH |
BACK_SPACE_WALL_WEST_ROLLDOOR | OVERHEAD DOOR_CON | 1.014 | 1.195 | 7.43 | BACK_SPACE_WALL_WEST |
CORE_RETAIL_WALL_WEST_2_DOOR3 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_WEST_2_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_WEST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR1 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR2 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
CORE_RETAIL_WALL_EAST_2_DOOR3 | SWINGING DOOR_CON | 2.281 | 3.464 | 1.95 | CORE_RETAIL_WALL_EAST_2 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
SKYLIGHTS_R4C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R4C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHTS_R3C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
POINT_OF_SALE_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_RETAIL_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
FRONT_ENTRY_WALL_SOUTH_GLAZING | 1.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
BACK_SPACE_LIGHTS | BACK_SPACE | 6.8133 | 379.89 | 2588.29 | LightsWired | BLDG_LIGHT_BACK_SCH | 60.89 | 168.00 | 60.06 | 0.0000 | Y | 29.18 |
CORE_RETAIL_LIGHTS | CORE_RETAIL | 15.4032 | 1600.48 | 24652.49 | LightsWired | BLDG_LIGHT_CORE_SCH | 69.21 | 168.00 | 52.76 | 0.0000 | Y | 244.14 |
POINT_OF_SALE_LIGHTS | POINT_OF_SALE | 15.4032 | 150.81 | 2322.95 | LightsWired | BLDG_LIGHT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 29.76 |
FRONT_RETAIL_LIGHTS | FRONT_RETAIL | 15.4032 | 150.81 | 2322.95 | LightsWired | BLDG_LIGHT_FRONT_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 29.76 |
FRONT_ENTRY_LIGHTS | FRONT_ENTRY | 8.7188 | 12.00 | 104.63 | LightsWired | BLDG_LIGHT_ENTRY_SCH | 69.21 | 168.00 | 68.25 | 0.0000 | Y | 1.34 |
Interior Lighting Total | 13.9457 | 2293.99 | 31991.30 | 334.19 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
CORE_RETAIL_DAYLREFPT1 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 24652.49 | 6163.12 |
CORE_RETAIL_DAYLREFPT2 | CORE_RETAIL | CORE_RETAIL_DAYLCTRL | SplitFlux | Stepped | 0.25 | 24652.49 | 6163.12 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 238.00 | AstronomicalClock | - | 41.77 | 41.77 | 1.87 | |
EXTERIOR_LIGHTS_B | 4328.05 | AstronomicalClock | - | 83.77 | 71.17 | 57.82 | |
Exterior Lighting Total | 4566.05 | 59.69 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 36948.34 | 27640.68 | 9307.66 | 0.75 | 3.80 | |||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 181403.78 | 124990.83 | 56412.95 | 0.69 | 3.40 | |||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 23447.54 | 16981.41 | 6466.13 | 0.72 | 3.80 | |||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 19172.02 | 13561.71 | 5610.31 | 0.71 | 3.80 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | 35436.5 | 11.44 | ||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | 175342.5 | 12.96 | ||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | 22559.2 | 120.05 | ||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | 18486.7 | 159.71 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
FRONT_ENTRY UNIT HEATER COIL | Coil:Heating:Fuel | 40769.97 | 0.80 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 49958.87 | 0.80 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 227212.53 | 0.80 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 30821.08 | 0.80 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25048.67 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 0.58 | 622.50 | 1.82 | 1942.45 | 1070.05 | 1.00 | 1.32 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.93 | 2059.91 | 1070.05 | 1.00 | 1.32 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.60 | 1018.41 | 7.69 | 12956.65 | 1684.71 | 1.00 | 1.16 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 |
PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 1.13 | 1250.78 | 1107.16 | 1.00 | 1.37 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 |
PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.87 | 963.92 | 1107.16 | 1.00 | 1.44 | General | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK | WaterHeater:Mixed | 0.15 | 11722.84 | 0.82 | 0.73 | 0.19 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 21760.93 | 26113.11 | 68.74 | 1.594 | 1.913 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00973 | 27.37 | 0.01445 | 0.232 | 0.00 |
CORE_RETAIL | 85422.68 | 102507.22 | 64.05 | 6.242 | 7.491 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00976 | 27.37 | 0.01445 | 1.890 | 0.00 |
POINT_OF_SALE | 12709.18 | 15251.01 | 101.13 | 0.941 | 1.130 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00903 | 27.37 | 0.01445 | 0.178 | 0.00 |
FRONT_RETAIL | 9861.78 | 11834.14 | 78.47 | 0.726 | 0.871 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 23.89 | 23.89 | 0.00945 | 27.37 | 0.01445 | 0.178 | 0.00 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 | 0.000 | 0.014 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 33.75 | 100.00 | 0.00001 | 34.40 | 0.01445 | 0.014 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
BACK_SPACE | 21381.23 | 25657.47 | 67.54 | 0.932 | 1.118 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00742 | -6.30 | 0.00230 | 0.232 | 0.00 |
CORE_RETAIL | 53882.89 | 64659.47 | 40.40 | 2.316 | 2.779 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00745 | -6.30 | 0.00230 | 1.890 | 0.00 |
POINT_OF_SALE | 10639.00 | 12766.80 | 84.65 | 0.466 | 0.559 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00764 | -6.30 | 0.00230 | 0.178 | 0.00 |
FRONT_RETAIL | 10642.08 | 12770.50 | 84.68 | 0.466 | 0.559 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 21.11 | 21.11 | 0.00764 | -6.30 | 0.00230 | 0.178 | 0.00 |
FRONT_ENTRY | 33944.26 | 40733.11 | 3394.43 | 1.513 | 1.815 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.03 | 0.00569 | -6.30 | 0.00230 | 0.014 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC:1 | 1.93 | 1.93 | 1.12 | 1.12 | 1.9251 | 1.9131 | 1.9251 | 0.9938 | 1.0000 |
PSZ-AC:2 | 7.69 | 7.69 | 2.78 | 2.78 | 7.6907 | 7.4908 | 7.6907 | 0.9740 | 1.0000 |
PSZ-AC:3 | 1.13 | 1.13 | 0.56 | 0.56 | 1.1297 | 1.1297 | 1.1297 | 1.0000 | 1.0000 |
PSZ-AC:4 | 0.87 | 0.87 | 0.56 | 0.56 | 0.8706 | 0.8706 | 0.8706 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | 40769.972 | 40769.972 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40769.97 | 40769.97 | 1.815293 | 20.82 | 12.20 | 0.00566694 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 0.0000 | 21.03 | 0.00569345 | 35.5533 | 40733.11 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:1 | 18474.170 | 0.000 | 1.925070 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 18474.17 | 14191.01 | 1.925070 | 24.38 | 17.47 | 0.01011260 | 12.80 | 11.77 | 0.00850000 | 27.97 | 0.01444568 | 21.76 | 12.0290 | 23.89 | 0.00972795 | 50.7387 | 21760.93 | 0.00 | -999.00 | -999.00 |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:1 | 49958.866 | 49958.866 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 49958.87 | 49958.87 | 1.925067 | 15.28 | 10.62 | 0.00635586 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 12.0290 | 21.11 | 0.00741558 | 45.9565 | 21381.23 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:2 | 90701.890 | 0.000 | 7.690710 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 90701.89 | 67453.27 | 7.690710 | 26.73 | 18.66 | 0.01066296 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 24.5779 | 23.89 | 0.00975987 | 50.9027 | 84185.94 | 0.00 | -999.00 | -999.00 |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:2 | 227212.531 | 227212.531 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 227212.53 | 227212.53 | 7.690710 | 2.38 | 1.41 | 0.00394634 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 24.5779 | 21.11 | 0.00745347 | 46.1860 | 53882.89 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:3 | 11723.770 | 0.000 | 1.129720 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 11723.77 | 9444.08 | 1.129720 | 25.64 | 17.72 | 0.00991061 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 15.7659 | 23.89 | 0.00903020 | 47.1451 | 11702.31 | 0.00 | -999.00 | -999.00 |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:3 | 30821.082 | 30821.082 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 30821.08 | 30821.08 | 1.129723 | 12.23 | 8.85 | 0.00593856 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 15.7659 | 21.11 | 0.00764126 | 47.3367 | 10639.00 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC:4 | 9586.010 | 0.000 | 0.870620 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 9586.01 | 7427.59 | 0.870620 | 26.10 | 18.14 | 0.01025086 | 12.80 | 11.77 | 0.00850000 | 34.40 | 0.01444567 | 23.51 | 20.4579 | 23.89 | 0.00945344 | 49.3262 | 9277.13 | 0.00 | -999.00 | -999.00 |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC:4 | 25048.673 | 25048.673 | -999.0 | -999.0 | -999.000 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25048.67 | 25048.67 | 0.870621 | 12.24 | 8.85 | 0.00593926 | 40.00 | 20.73 | 0.00800000 | -6.30 | 0.00229779 | -6.30 | 20.4579 | 21.11 | 0.00764155 | 47.3385 | 10642.08 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
FRONT_ENTRY UNIT HEATER COIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | FRONT_ENTRY UNIT HEATER | FRONT_ENTRY | N/A | N/A | N/A | Yes | No | unknown | No | 40769.972 | 40769.972 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | FRONT_ENTRY UNIT HEATERFAN | Fan:ConstantVolume | 1.815293 | 2.10751310 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 40769.97 | 40769.97 | 1.0000 | 2.10751310 | 1.815293 | 20.82 | 12.20 | 0.00566694 | 35308.2 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 40769.97 | -6.30 | 0.00229779 | -6.30 | 0.00000000 | 0.0000 | 21.05 | 0.00569345 | 21.03 | 0.00569345 | 35.5533 | 40733.11 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 18474.170 | 0.000 | 1.925070 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.6388 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 18474.17 | 14191.01 | 1.0000 | 2.23496111 | 1.925070 | 24.38 | 17.47 | 0.01011260 | 50244.0 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18474.17 | 27.97 | 0.01444568 | 21.76 | 0.23156651 | 12.0290 | 23.89 | 0.00952010 | 23.89 | 0.00972795 | 50.7387 | 21760.93 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:1 | BACK_SPACE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 49958.866 | 49958.866 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.925067 | 2.23495787 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 49958.87 | 49958.87 | 1.0000 | 2.23495787 | 1.925067 | 15.28 | 10.62 | 0.00635586 | 31425.1 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 49958.87 | -6.30 | 0.00229779 | -6.30 | 0.23156651 | 12.0290 | 20.91 | 0.00741558 | 21.11 | 0.00741558 | 45.9565 | 21381.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 90701.890 | 0.000 | 7.690710 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1024.6619 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:20:00 | 90701.89 | 67453.27 | 1.0000 | 8.92873389 | 7.690710 | 26.73 | 18.66 | 0.01066296 | 54057.1 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 90701.89 | 34.40 | 0.01444567 | 23.51 | 1.89021192 | 24.5779 | 23.89 | 0.00926092 | 23.89 | 0.00975987 | 50.9027 | 84185.94 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:2 | CORE_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 227212.531 | 227212.531 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 7.690710 | 8.92873386 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 227212.53 | 227212.53 | 1.0000 | 8.92873386 | 7.690710 | 2.38 | 1.41 | 0.00394634 | 12280.3 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 227212.53 | -6.30 | 0.00229779 | -6.30 | 1.89021192 | 24.5779 | 20.85 | 0.00745347 | 21.11 | 0.00745347 | 46.1860 | 53882.89 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 11723.770 | 0.000 | 1.129720 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.2633 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:00:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 11723.77 | 9444.08 | 1.0000 | 1.31157842 | 1.129720 | 25.64 | 17.72 | 0.00991061 | 51022.0 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 11723.77 | 34.40 | 0.01444567 | 23.51 | 0.17811053 | 15.7659 | 23.89 | 0.00900376 | 23.89 | 0.00903020 | 47.1451 | 11702.31 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:3 | POINT_OF_SALE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 30821.082 | 30821.082 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.129723 | 1.31158191 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 30821.08 | 30821.08 | 1.0000 | 1.31158191 | 1.129723 | 12.23 | 8.85 | 0.00593856 | 27281.2 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 30821.08 | -6.30 | 0.00229779 | -6.30 | 0.17811053 | 15.7659 | 20.90 | 0.00764126 | 21.11 | 0.00764126 | 47.3367 | 10639.00 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 9586.010 | 0.000 | 0.870620 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1023.8958 | 1004.8586 | 1.1610 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:10:00 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 9586.01 | 7427.59 | 1.0000 | 1.01076940 | 0.870620 | 26.10 | 18.14 | 0.01025086 | 52358.0 | 12.80 | 11.77 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9586.01 | 34.40 | 0.01444567 | 23.51 | 0.17811053 | 20.4579 | 23.89 | 0.00913442 | 23.89 | 0.00945344 | 49.3262 | 9277.13 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC:4 | FRONT_RETAIL | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25048.673 | 25048.673 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1610 | PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.870621 | 1.01077071 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | ATLANTA-HARTSFIELD.JACKSON.INTL.AP_GA_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 25048.67 | 25048.67 | 1.0000 | 1.01077071 | 0.870621 | 12.24 | 8.85 | 0.00593926 | 27285.6 | 40.00 | 20.73 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25048.67 | -6.30 | 0.00229779 | -6.30 | 0.17811053 | 20.4579 | 20.90 | 0.00764155 | 21.11 | 0.00764155 | 47.3385 | 10642.08 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC:1_OA_CONTROLLER | DifferentialEnthalpy | 0.23 | 1.93 | - | |||
PSZ-AC:2_OA_CONTROLLER | DifferentialEnthalpy | 1.89 | 7.69 | - | |||
PSZ-AC:3_OA_CONTROLLER | DifferentialEnthalpy | 0.18 | 1.13 | - | |||
PSZ-AC:4_OA_CONTROLLER | DifferentialEnthalpy | 0.18 | 0.87 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
BACK_SPACE | 2665.83 | 2590.67 | 856.33 |
CORE_RETAIL | 2516.17 | 1670.33 | 131.17 |
POINT_OF_SALE | 2769.50 | 1682.17 | 289.17 |
FRONT_RETAIL | 2688.33 | 2211.50 | 568.50 |
FRONT_ENTRY | 0.00 | 0.00 | 0.00 |
Facility | 3242.83 | 2662.83 | 907.67 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
BACK_SPACE | 0.33 | 0.00 | 0.00 | 0.00 |
CORE_RETAIL | 0.00 | 0.00 | 0.00 | 0.00 |
POINT_OF_SALE | 0.50 | 0.00 | 0.00 | 0.00 |
FRONT_RETAIL | 1.00 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | 0.33 | 0.00 | 0.00 | 0.00 |
Facility | 1.67 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.32 | 61.34 | 2317.33 | 0.535 | 0.029 | 0.000 | 0.000 |
CORE_RETAIL | 127.72 | 258.43 | 9762.95 | 0.821 | 0.006 | 0.000 | 0.000 |
POINT_OF_SALE | 12.04 | 24.35 | 919.94 | 1.023 | 0.032 | 0.000 | 0.000 |
FRONT_RETAIL | 12.04 | 24.35 | 919.94 | 0.866 | 0.032 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
BACK_SPACE | 30.32 | 61.34 | 2317.33 | 0.351 | 0.000 | 0.000 | 0.000 |
CORE_RETAIL | 127.72 | 258.43 | 9762.95 | 0.682 | 0.000 | 0.000 | 0.000 |
POINT_OF_SALE | 12.04 | 24.35 | 919.94 | 0.681 | 0.000 | 0.000 | 0.000 |
FRONT_RETAIL | 12.04 | 24.35 | 919.94 | 0.681 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Surfaces by ClassTotal | Outdoors | |
Wall | 26 | 10 |
Floor | 5 | 5 |
Roof | 5 | 5 |
Internal Mass | 5 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 19 | 19 |
Door | 13 | 13 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 4 |
Conditioned Zones | 5 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
Electricity:Building | 529.35 | 2983.86 | 14-MAY-08:00 | 39264.11 | 02-JAN-15:30 |
Electricity:Zone:BACK_SPACE | 79.17 | 589.27 | 01-JAN-00:10 | 4789.50 | 02-JAN-09:10 |
InteriorLights:Electricity | 334.19 | 1188.69 | 14-MAY-08:00 | 28493.07 | 02-JAN-15:30 |
InteriorLights:Electricity:Zone:BACK_SPACE | 29.18 | 129.41 | 01-JAN-00:10 | 2030.36 | 02-JAN-09:10 |
LightsWired:InteriorLights:Electricity | 334.19 | 1188.69 | 14-MAY-08:00 | 28493.07 | 02-JAN-15:30 |
Electricity:Zone:CORE_RETAIL | 328.44 | 1597.18 | 14-MAY-08:00 | 26839.84 | 02-JAN-15:30 |
InteriorLights:Electricity:Zone:CORE_RETAIL | 244.15 | 821.75 | 14-MAY-08:00 | 22187.24 | 02-JAN-15:30 |
Electricity:Zone:POINT_OF_SALE | 82.68 | 602.96 | 01-JAN-00:10 | 5011.54 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:POINT_OF_SALE | 29.76 | 116.15 | 01-JAN-00:10 | 2090.65 | 02-JAN-09:10 |
Electricity:Zone:FRONT_RETAIL | 37.71 | 189.21 | 01-JAN-00:10 | 2529.06 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_RETAIL | 29.76 | 116.15 | 01-JAN-00:10 | 2090.65 | 02-JAN-09:10 |
Electricity:Zone:FRONT_ENTRY | 1.34 | 5.23 | 01-JAN-00:10 | 94.16 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:FRONT_ENTRY | 1.34 | 5.23 | 01-JAN-00:10 | 94.16 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:BACK_SPACE | 49.99 | 459.86 | 01-JAN-00:10 | 2759.14 | 02-JAN-09:10 |
MiscPlug:InteriorEquipment:Electricity | 195.16 | 1795.17 | 01-JAN-00:10 | 10771.04 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:CORE_RETAIL | 84.30 | 775.43 | 01-JAN-00:10 | 4652.60 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:POINT_OF_SALE | 52.92 | 486.81 | 01-JAN-00:10 | 2920.89 | 02-JAN-09:10 |
InteriorEquipment:Electricity:Zone:FRONT_RETAIL | 7.94 | 73.07 | 01-JAN-00:10 | 438.40 | 02-JAN-09:10 |
ElectricityPurchased:Facility | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
ElectricityPurchased:Plant | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
Cogeneration:ElectricityPurchased | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
ElectricityNet:Plant | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
Cogeneration:ElectricityNet | 973.92 | 3189.30 | 14-MAY-07:00 | 84146.97 | 07-JUL-15:50 |
Electricity:HVAC | 384.89 | 0.00 | 01-JAN-00:10 | 52929.20 | 08-JUL-14:30 |
Fans:Electricity | 146.49 | 0.00 | 01-JAN-00:10 | 11923.34 | 09-JAN-07:10 |
General:Fans:Electricity | 146.49 | 0.00 | 01-JAN-00:10 | 11923.34 | 09-JAN-07:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 219.20 | 0.00 | 01-JAN-00:10 | 43221.37 | 08-JUL-14:30 |
ExteriorLights:Electricity | 59.69 | 0.00 | 01-JAN-07:50 | 4566.05 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 59.69 | 0.00 | 01-JAN-07:50 | 4566.05 | 01-JAN-06:10 |
HeatRecovery:Electricity | 19.20 | 0.00 | 01-JAN-00:10 | 1406.23 | 02-JAN-07:50 |
Electricity:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 169.65 | 1862.00 | 19-JAN-11:00 | 134676.23 | 12-FEB-09:10 |
Gas:Plant | 91.29 | 1862.00 | 19-JAN-11:00 | 5045.63 | 03-FEB-13:00 |
WaterSystems:Gas | 91.29 | 1862.00 | 19-JAN-11:00 | 5045.63 | 03-FEB-13:00 |
Water Heater:WaterSystems:Gas | 91.29 | 1862.00 | 19-JAN-11:00 | 5045.63 | 03-FEB-13:00 |
Gas:HVAC | 78.36 | 0.00 | 01-JAN-00:10 | 132814.23 | 12-FEB-09:10 |
Heating:Gas | 78.36 | 0.00 | 01-JAN-00:10 | 132814.23 | 12-FEB-09:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 134.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1880.47 | 0.00 | 01-JAN-00:10 | 271535.70 | 08-JUL-14:00 |
EnergyTransfer:Building | 689.53 | 0.00 | 01-JAN-00:10 | 94910.04 | 09-JAN-07:10 |
EnergyTransfer:Zone:BACK_SPACE | 92.50 | 0.00 | 01-JAN-00:10 | 21872.82 | 13-FEB-06:10 |
Heating:EnergyTransfer | 59.89 | 0.00 | 01-JAN-00:10 | 88536.72 | 09-JAN-06:10 |
Heating:EnergyTransfer:Zone:BACK_SPACE | 8.32 | 0.00 | 01-JAN-00:10 | 21872.82 | 13-FEB-06:10 |
Cooling:EnergyTransfer | 629.64 | 0.00 | 01-JAN-00:10 | 86078.35 | 07-JUL-14:50 |
Cooling:EnergyTransfer:Zone:BACK_SPACE | 84.18 | 0.00 | 01-JAN-00:10 | 13931.34 | 08-JUL-15:30 |
EnergyTransfer:Zone:CORE_RETAIL | 418.86 | 0.00 | 01-JAN-00:10 | 56266.95 | 09-JUL-08:10 |
Heating:EnergyTransfer:Zone:CORE_RETAIL | 7.34 | 0.00 | 01-JAN-00:10 | 49575.06 | 09-JAN-07:10 |
Cooling:EnergyTransfer:Zone:CORE_RETAIL | 411.52 | 0.00 | 01-JAN-00:10 | 56097.10 | 07-JUL-14:40 |
EnergyTransfer:Zone:POINT_OF_SALE | 82.76 | 0.00 | 01-JAN-00:10 | 10170.89 | 11-OCT-14:10 |
Heating:EnergyTransfer:Zone:POINT_OF_SALE | 1.48 | 0.00 | 01-JAN-00:10 | 9190.14 | 12-FEB-08:10 |
Cooling:EnergyTransfer:Zone:POINT_OF_SALE | 81.27 | 0.00 | 01-JAN-00:10 | 10170.89 | 11-OCT-14:10 |
EnergyTransfer:Zone:FRONT_RETAIL | 55.43 | 0.00 | 01-JAN-00:10 | 10981.08 | 09-JAN-07:10 |
Heating:EnergyTransfer:Zone:FRONT_RETAIL | 2.76 | 0.00 | 01-JAN-00:10 | 10532.07 | 12-FEB-08:10 |
Cooling:EnergyTransfer:Zone:FRONT_RETAIL | 52.67 | 0.00 | 01-JAN-00:10 | 8064.26 | 11-OCT-14:10 |
EnergyTransfer:Zone:FRONT_ENTRY | 39.98 | 0.00 | 01-JAN-00:10 | 31951.39 | 07-JAN-18:00 |
Heating:EnergyTransfer:Zone:FRONT_ENTRY | 39.98 | 0.00 | 01-JAN-00:10 | 31951.39 | 07-JAN-18:00 |
Cooling:EnergyTransfer:Zone:FRONT_ENTRY | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 1190.94 | 0.00 | 01-JAN-00:10 | 186681.14 | 08-JUL-14:00 |
HeatingCoils:EnergyTransfer | 62.69 | 0.00 | 01-JAN-00:10 | 106251.39 | 12-FEB-09:10 |
CoolingCoils:EnergyTransfer | 806.13 | 0.00 | 01-JAN-00:10 | 152329.34 | 20-AUG-08:10 |
HeatRecoveryForHeating:EnergyTransfer | 171.42 | 0.00 | 01-JAN-00:10 | 59255.00 | 11-FEB-18:10 |
HeatRecoveryForCooling:EnergyTransfer | 150.71 | 0.00 | 01-JAN-00:10 | 42498.52 | 07-JUL-12:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
BACK_SPACE | 0.000 | 0.000 | 8.325 | -84.174 | 0.000 | 0.000 | 38.185 | 29.179 | 49.992 | 0.000 | 0.000 | 0.546 | 0.000 | 0.000 | 0.000 | 0.000 | -11.838 | -30.215 |
CORE_RETAIL | 0.000 | 0.000 | 7.340 | -411.511 | 0.000 | 0.000 | 156.352 | 244.145 | 84.299 | 73.384 | 0.000 | 0.448 | 0.000 | 0.000 | -22.895 | 0.000 | -10.908 | -120.653 |
POINT_OF_SALE | 0.000 | 0.000 | 1.484 | -81.271 | 0.000 | 0.000 | 14.879 | 29.762 | 52.922 | 26.822 | 0.000 | 0.227 | 0.001 | 0.000 | -16.312 | 0.000 | -5.598 | -22.916 |
FRONT_RETAIL | 0.000 | 0.000 | 2.761 | -52.670 | 0.000 | 0.000 | 15.130 | 29.762 | 7.943 | 26.918 | 0.000 | 0.232 | 0.001 | 0.000 | -15.542 | 0.000 | -5.230 | -9.304 |
FRONT_ENTRY | 39.981 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.340 | 0.000 | 5.256 | 0.000 | 0.874 | 0.000 | 0.000 | -3.186 | 0.000 | -43.685 | -0.581 |
Total Facility | 39.981 | 0.000 | 19.909 | -629.626 | 0.000 | 0.000 | 224.546 | 334.189 | 195.156 | 132.381 | 0.000 | 2.328 | 0.002 | 0.000 | -57.936 | 0.000 | -77.260 | -183.669 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 14-SEP-06:02 | 0.00 | 0.00 | 0.00 | -39060.74 | 0.00 | 0.00 | 401.34 | 451.19 | 1226.28 | 0.00 | 0.00 | 0.00 | 37175.12 | 0.00 | -0.00 | 0.00 | -193.20 | 0.00 |
CORE_RETAIL | 12-OCT-06:02 | 0.00 | 0.00 | 0.00 | -218288.42 | 0.00 | 0.00 | 1642.39 | 4930.50 | 2067.82 | 0.00 | 0.00 | 0.00 | 211954.47 | 0.00 | -2087.52 | 0.00 | -219.24 | 0.00 |
POINT_OF_SALE | 12-OCT-06:02 | 0.00 | 0.00 | 0.00 | -26335.79 | 0.00 | 0.00 | 151.28 | 464.59 | 1298.17 | 0.00 | 0.00 | 0.00 | 26060.13 | 0.00 | -1522.41 | 0.00 | -115.98 | 0.00 |
FRONT_RETAIL | 15-SEP-06:02 | 0.00 | 0.00 | 0.00 | -18216.47 | 0.00 | 0.00 | 156.34 | 464.59 | 194.85 | 0.00 | 0.00 | 0.00 | 18401.07 | 0.00 | -1000.38 | 0.00 | 0.00 | 0.00 |
FRONT_ENTRY | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 12-OCT-06:02 | 0.00 | 0.00 | 0.00 | -271917.52 | 0.00 | 0.00 | 2374.59 | 6331.79 | 4787.13 | 0.00 | 0.00 | 0.00 | 264549.94 | 0.00 | -5394.12 | 0.00 | -731.81 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
BACK_SPACE | 12-FEB-08:61 | 0.00 | 0.00 | 50708.61 | 0.00 | 0.00 | 0.00 | 0.00 | 129.41 | 459.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -965.45 | -50332.43 |
CORE_RETAIL | 12-FEB-08:61 | 0.00 | 0.00 | 233752.84 | 0.00 | 0.00 | 0.00 | 0.00 | 1232.62 | 775.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2560.11 | 0.00 | -823.02 | -232377.77 |
POINT_OF_SALE | 12-FEB-08:61 | 0.00 | 0.00 | 30881.34 | 0.00 | 0.00 | 0.00 | 0.00 | 116.15 | 486.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1277.57 | 0.00 | -422.75 | -29783.98 |
FRONT_RETAIL | 12-FEB-07:01 | 0.00 | 0.00 | 25214.00 | 0.00 | 0.00 | 0.00 | 0.00 | 116.15 | 73.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2362.19 | 0.00 | -1992.49 | -21048.54 |
FRONT_ENTRY | 07-JAN-18:00 | 31950.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 94.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -434.49 | 0.00 | -31545.92 | -64.08 |
Total Facility | 12-FEB-08:61 | 8291.32 | 0.00 | 340542.73 | 0.00 | 0.00 | 0.00 | 0.00 | 1599.57 | 1795.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -5328.38 | 0.00 | -7806.78 | -339093.63 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.9131 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.9251 | 0.1203 | 1.0000 | 0.2316 | 0.1203 | ||
PSZ-AC:2 | 7.4908 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.6907 | 0.2458 | 1.0000 | 1.8902 | 0.2458 | ||
PSZ-AC:3 | 1.1297 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1297 | 0.1577 | 1.0000 | 0.1781 | 0.1577 | ||
PSZ-AC:4 | 0.8706 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.8706 | 0.2046 | 1.0000 | 0.1781 | 0.2046 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC:1 | 1.9131 | 0.0000 | 61.3418 | 1.0000 | 0.2316 | 1.9131 | 1.0000 | 1.0000 | 0.2316 | 0.1210 | ||
PSZ-AC:2 | 7.4908 | 0.0000 | 258.4342 | 1.0000 | 1.8902 | 7.4908 | 1.0000 | 1.0000 | 1.8902 | 0.2523 | ||
PSZ-AC:3 | 1.1297 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 1.1297 | 1.0000 | 1.0000 | 0.1781 | 0.1577 | ||
PSZ-AC:4 | 0.8706 | 0.0000 | 24.3517 | 1.0000 | 0.1781 | 0.8706 | 1.0000 | 1.0000 | 0.1781 | 0.2046 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
BACK_SPACE | PSZ-AC:1 | 0.000000 | 61.3418 | 0.000610 | 379.89 | 0.2316 | 1.0000 | 0.2316 | 1.000 | 0.2316 |
CORE_RETAIL | PSZ-AC:2 | 0.000000 | 258.4342 | 0.001181 | 1600.48 | 1.8902 | 1.0000 | 1.8902 | 1.000 | 1.8902 |
POINT_OF_SALE | PSZ-AC:3 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
FRONT_RETAIL | PSZ-AC:4 | 0.000000 | 24.3517 | 0.001181 | 150.81 | 0.1781 | 1.0000 | 0.1781 | 1.000 | 0.1781 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC:1 | 0.000000 | 61.34 | 0.000610 | 379.8900 | 0.2316 | 0.2316 | 0.2316 |
PSZ-AC:2 | 0.000000 | 258.43 | 0.001181 | 1600.4829 | 1.8902 | 1.8902 | 1.8902 |
PSZ-AC:3 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
PSZ-AC:4 | 0.000000 | 24.35 | 0.001181 | 150.8100 | 0.1781 | 0.1781 | 0.1781 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.9131 | 1.9131 | 1.9131 | 0.2316 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.4908 | 7.4908 | 7.4908 | 1.8902 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1297 | 1.1297 | 1.1297 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.8706 | 0.8706 | 0.8706 | 0.1781 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.9131 | 1.9251 | 1.9131 | 1.9131 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.4908 | 7.6907 | 7.4908 | 7.4908 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1297 | 1.1297 | 1.1297 | 1.1297 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.8706 | 0.8706 | 0.8706 | 0.8706 | 0.1781 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
BACK_SPACE | PSZ-AC:1 | 1.9131 | 1.9131 | 1.9131 | 0.2316 | 0.2071 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
CORE_RETAIL | PSZ-AC:2 | 7.4908 | 7.4908 | 7.4908 | 1.8902 | 0.6802 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
POINT_OF_SALE | PSZ-AC:3 | 1.1297 | 1.1297 | 1.1297 | 0.1781 | 0.3187 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
FRONT_RETAIL | PSZ-AC:4 | 0.8706 | 0.8706 | 0.8706 | 0.1781 | 0.3186 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC:1 | 1.9131 | 1.9131 | 1.9131 | 1.9131 | 0.2316 | 1.0000 |
PSZ-AC:2 | 7.4908 | 7.4908 | 7.4908 | 7.4908 | 1.8902 | 1.0000 |
PSZ-AC:3 | 1.1297 | 1.1297 | 1.1297 | 1.1297 | 0.1781 | 1.0000 |
PSZ-AC:4 | 0.8706 | 0.8706 | 0.8706 | 0.8706 | 0.1781 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:13:29
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Atlanta-Hartsfield Jackson Intl AP GA USA TMY3 WMO#=722190 |
Total gross floor area [m2] | 2293.99 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
BACK_SPACE | 379.89 | 379.89 | 0.00 | 94.22 |
CORE_RETAIL | 1600.48 | 1600.48 | 0.00 | 94.22 |
POINT_OF_SALE | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_RETAIL | 150.81 | 150.81 | 0.00 | 94.22 |
FRONT_ENTRY | 12.00 | 12.00 | 0.00 | 0.00 |
Totals | 2293.99 | 2293.99 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 78.36 | 132814.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 219.20 | 43221.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 334.19 | 28493.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 59.69 | 4566.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 195.16 | 10771.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 146.49 | 11923.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 19.20 | 1406.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 91.29 | 5045.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 195.16 | 973.92 |
Natural Gas | 0.00 | 169.65 |
Additional | 0.00 | 0.00 |
Total | 195.16 | 1143.57 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 145.68 |
Space Heating | 0.00 |
Space Cooling | 95.55 |
Fans (All) | 63.86 |
Service Water Heating | 0.00 |
Receptacle Equipment | 85.07 |
Miscellaneous (All) | 424.55 |
Subtotal | 424.55 |
Natural Gas [MJ/m2] | |
Space Heating | 34.16 |
Service Water Heating | 39.80 |
Miscellaneous (All) | 73.96 |
Subtotal | 73.96 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 29.22 |
Space Heating | 6.85 |
Space Cooling | 19.17 |
Fans (All) | 12.81 |
Service Water Heating | 7.98 |
Receptacle Equipment | 17.07 |
Miscellaneous | 6.90 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
FRONTENTRY_COILSCHED | 8760. | 8760. |
FRONTENTRY_FANSCHED | 8760. | 8760. |
BLDG_LIGHT_BACK_SCH | 3175. | 8760. |
BLDG_LIGHT_CORE_SCH | 3609. | 8760. |
BLDG_LIGHT_ENTRY_SCH | 3609. | 8760. |
BLDG_LIGHT_FRONT_SCH | 3609. | 8760. |
BLDG_LIGHT_SCH | 3609. | 8760. |
BLDG_OCC_SCH | 2410. | 4950. |
BLDG_EQUIP_SCH | 4572. | 8760. |
BLDG_ELEVATORS | 2743. | 4950. |
INFIL_SCH | 3551. | 3551. |
INFIL_HALF_ON_SCH | 6156. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
BLDG_SWH_SCH | 2009. | 4950. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6543. | 8760. |
ALWAYS_OFF | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4950. | 4950. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
INFIL_SCH_PNNL | 4774. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4950. | 4950. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
CLGSETP_SCH_YES_OPTIMUM | BACK_SPACE DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
FRONT_ENTRY_COOLING | FRONT_ENTRY DUALSPSCHED | July | 100.00 | 365 | 100.00 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2015
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTANDALONE
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3A
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_GA_ATLANTA
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.357569E+11 |
February | 0.000 | 0.192873E+11 |
March | 0.000 | 0.361833E+10 |
April | 0.000 | 0.973881E+09 |
May | 0.000 | 0.150012E+08 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.375303E+08 |
October | 0.000 | 0.123243E+10 |
November | 0.000 | 0.363306E+10 |
December | 0.000 | 0.138085E+11 |
Annual Sum or Average | 0.783629E+11 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.357569E+11 |
Report: ZoneCoolingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.769765E+09 | 6571.00 | 26-JAN-07:05 | -5.1 | -7.0 | 0.169869E+10 | 2451.20 | 20-JAN-15:00 | 17.20 | 12.76 |
February | 0.135259E+10 | 7121.12 | 03-FEB-07:05 | -8.9 | -10.1 | 0.167447E+10 | 2451.27 | 22-FEB-15:00 | 14.40 | 13.41 |
March | 0.350185E+10 | 20044.78 | 31-MAR-06:02 | 17.30 | 16.12 | 0.214458E+10 | 2451.28 | 11-MAR-13:30 | 24.15 | 15.43 |
April | 0.501405E+10 | 24150.23 | 19-APR-06:02 | 15.68 | 14.03 | 0.212377E+10 | 2451.30 | 28-APR-14:00 | 25.60 | 15.82 |
May | 0.853574E+10 | 35450.34 | 17-MAY-06:02 | 16.78 | 13.16 | 0.223005E+10 | 2451.23 | 12-MAY-14:09 | 23.90 | 15.17 |
June | 0.126730E+11 | 38261.13 | 10-JUN-06:02 | 12.48 | 9.21 | 0.220235E+10 | 2451.21 | 09-JUN-14:09 | 29.90 | 18.88 |
July | 0.143422E+11 | 29624.20 | 03-JUL-06:02 | 18.68 | 16.73 | 0.218814E+10 | 2451.26 | 29-JUL-10:09 | 18.48 | 18.48 |
August | 0.151746E+11 | 28523.97 | 26-AUG-06:02 | 21.78 | 17.45 | 0.228192E+10 | 2451.24 | 26-AUG-10:09 | 27.48 | 20.44 |
September | 0.106591E+11 | 39069.87 | 14-SEP-06:02 | 12.30 | 10.99 | 0.215695E+10 | 2451.29 | 28-SEP-14:00 | 19.40 | 17.92 |
October | 0.625139E+10 | 28924.59 | 11-OCT-06:02 | 17.70 | 16.28 | 0.215258E+10 | 2451.25 | 28-OCT-10:50 | 14.32 | 14.32 |
November | 0.363266E+10 | 19065.28 | 04-NOV-06:02 | 16.10 | 15.06 | 0.196569E+10 | 2451.25 | 01-NOV-14:00 | 20.60 | 15.19 |
December | 0.226900E+10 | 6570.41 | 18-DEC-07:05 | -5.1 | -6.8 | 0.181282E+10 | 2451.23 | 11-DEC-15:00 | 21.10 | 15.90 |
Annual Sum or Average | 0.841760E+11 | 0.246320E+11 | ||||||||
Minimum of Months | 0.769765E+09 | 6570.41 | -8.9 | -10.1 | 0.167447E+10 | 2451.20 | 14.32 | 12.76 | ||
Maximum of Months | 0.151746E+11 | 39069.87 | 21.78 | 17.45 | 0.228192E+10 | 2451.30 | 29.90 | 20.44 |
Report: ZoneCoolingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.919241E+10 | 17136.86 | 20-JAN-16:00 | 17.20 | 12.76 | 0.818451E+10 | 10327.16 | 21-JAN-13:39 | 7.93 | 4.31 |
February | 0.130703E+11 | 29440.71 | 28-FEB-16:00 | 23.30 | 12.51 | 0.793087E+10 | 10328.24 | 22-FEB-15:39 | 16.27 | 13.43 |
March | 0.264764E+11 | 139950.59 | 31-MAR-06:02 | 17.30 | 16.12 | 0.957507E+10 | 10327.57 | 11-MAR-11:09 | 18.87 | 12.85 |
April | 0.339967E+11 | 173791.09 | 15-APR-06:03 | 12.07 | 8.72 | 0.907900E+10 | 10327.46 | 07-APR-14:09 | 22.57 | 13.55 |
May | 0.446238E+11 | 163342.17 | 14-MAY-08:62 | 16.15 | 12.74 | 0.940818E+10 | 10327.11 | 10-MAY-14:09 | 20.78 | 12.15 |
June | 0.532755E+11 | 198669.53 | 08-JUN-06:02 | 12.07 | 8.46 | 0.927886E+10 | 10327.19 | 09-JUN-14:09 | 29.90 | 18.88 |
July | 0.565729E+11 | 134122.89 | 03-JUL-06:02 | 18.68 | 16.73 | 0.921874E+10 | 10327.10 | 25-JUL-14:09 | 30.40 | 23.43 |
August | 0.584260E+11 | 136758.65 | 26-AUG-06:02 | 21.78 | 17.45 | 0.961380E+10 | 10327.14 | 26-AUG-11:20 | 29.47 | 21.46 |
September | 0.452366E+11 | 175824.03 | 14-SEP-06:02 | 12.30 | 10.99 | 0.908802E+10 | 10327.08 | 15-SEP-14:09 | 28.48 | 18.73 |
October | 0.345680E+11 | 218329.37 | 12-OCT-06:02 | 8.12 | 5.86 | 0.919688E+10 | 10327.31 | 04-OCT-14:09 | 19.68 | 12.49 |
November | 0.222457E+11 | 140462.66 | 04-NOV-06:02 | 16.10 | 15.06 | 0.880035E+10 | 10327.25 | 25-NOV-12:09 | 12.48 | 7.09 |
December | 0.138320E+11 | 114098.33 | 13-DEC-07:03 | 16.70 | 15.65 | 0.892500E+10 | 10327.32 | 16-DEC-11:30 | 9.20 | 6.76 |
Annual Sum or Average | 0.411516E+12 | 0.108299E+12 | ||||||||
Minimum of Months | 0.919241E+10 | 17136.86 | 8.12 | 5.86 | 0.793087E+10 | 10327.08 | 7.93 | 4.31 | ||
Maximum of Months | 0.584260E+11 | 218329.37 | 23.30 | 17.45 | 0.961380E+10 | 10328.24 | 30.40 | 23.43 |
Report: ZoneCoolingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.307540E+10 | 5352.39 | 27-JAN-07:05 | -6.7 | -7.8 | 0.738678E+09 | 973.16 | 31-JAN-15:00 | 20.00 | 13.57 |
February | 0.355088E+10 | 7196.27 | 28-FEB-15:40 | 23.87 | 12.90 | 0.707532E+09 | 973.30 | 22-FEB-15:39 | 16.27 | 13.43 |
March | 0.538475E+10 | 18808.71 | 31-MAR-06:02 | 17.30 | 16.12 | 0.882828E+09 | 973.16 | 11-MAR-11:09 | 18.87 | 12.85 |
April | 0.562194E+10 | 23126.81 | 18-APR-06:02 | 13.30 | 12.05 | 0.849007E+09 | 973.13 | 07-APR-14:09 | 22.57 | 13.55 |
May | 0.713247E+10 | 21934.73 | 17-MAY-06:02 | 16.78 | 13.16 | 0.885646E+09 | 973.13 | 23-MAY-14:09 | 23.53 | 20.59 |
June | 0.898776E+10 | 22706.39 | 07-JUN-06:02 | 13.48 | 11.64 | 0.874298E+09 | 973.13 | 17-JUN-14:09 | 29.85 | 21.85 |
July | 0.993222E+10 | 17737.40 | 03-JUL-06:02 | 18.68 | 16.73 | 0.868662E+09 | 973.14 | 03-JUL-14:20 | 29.80 | 22.07 |
August | 0.110833E+11 | 17572.51 | 26-AUG-06:02 | 21.78 | 17.45 | 0.905878E+09 | 973.14 | 26-AUG-11:50 | 30.32 | 21.88 |
September | 0.894369E+10 | 24040.17 | 14-SEP-06:02 | 12.30 | 10.99 | 0.856320E+09 | 973.16 | 25-SEP-14:20 | 30.20 | 19.96 |
October | 0.751034E+10 | 26339.62 | 12-OCT-06:02 | 8.12 | 5.86 | 0.860807E+09 | 973.16 | 28-OCT-15:09 | 17.20 | 17.20 |
November | 0.576795E+10 | 19084.74 | 04-NOV-06:02 | 16.10 | 15.06 | 0.817378E+09 | 973.14 | 01-NOV-14:00 | 20.60 | 15.19 |
December | 0.428210E+10 | 16469.14 | 13-DEC-07:03 | 16.70 | 15.65 | 0.811141E+09 | 973.13 | 11-DEC-15:30 | 21.10 | 15.19 |
Annual Sum or Average | 0.812728E+11 | 0.100582E+11 | ||||||||
Minimum of Months | 0.307540E+10 | 5352.39 | -6.7 | -7.8 | 0.707532E+09 | 973.13 | 16.27 | 12.85 | ||
Maximum of Months | 0.110833E+11 | 26339.62 | 23.87 | 17.45 | 0.905878E+09 | 973.30 | 30.32 | 22.07 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.155055E+10 | 4672.96 | 15-JAN-09:05 | -2.9 | -5.0 | 0.690175E+09 | 973.12 | 31-JAN-15:00 | 20.00 | 13.57 |
February | 0.188058E+10 | 4982.55 | 27-FEB-16:00 | 22.80 | 11.28 | 0.669773E+09 | 973.16 | 22-FEB-15:20 | 18.13 | 13.10 |
March | 0.305528E+10 | 11747.14 | 31-MAR-06:02 | 17.30 | 16.12 | 0.848885E+09 | 973.13 | 11-MAR-11:39 | 20.57 | 13.67 |
April | 0.321437E+10 | 9352.86 | 18-APR-06:02 | 13.30 | 12.05 | 0.832651E+09 | 973.13 | 28-APR-14:00 | 25.60 | 15.82 |
May | 0.435959E+10 | 15569.76 | 19-MAY-06:02 | 16.57 | 15.53 | 0.882160E+09 | 973.10 | 10-MAY-14:09 | 20.78 | 12.15 |
June | 0.619257E+10 | 16811.25 | 07-JUN-06:02 | 13.48 | 11.64 | 0.873930E+09 | 973.10 | 07-JUN-14:09 | 23.40 | 14.97 |
July | 0.707537E+10 | 14229.78 | 03-JUL-06:02 | 18.68 | 16.73 | 0.868599E+09 | 973.11 | 15-JUL-10:09 | 30.18 | 23.74 |
August | 0.806707E+10 | 13878.94 | 26-AUG-06:02 | 21.78 | 17.45 | 0.905868E+09 | 973.11 | 28-AUG-14:09 | 28.48 | 22.14 |
September | 0.616586E+10 | 18219.41 | 15-SEP-06:02 | 14.50 | 12.25 | 0.855620E+09 | 973.12 | 25-SEP-14:09 | 30.40 | 20.08 |
October | 0.498162E+10 | 16141.89 | 10-OCT-06:02 | 15.00 | 14.30 | 0.843085E+09 | 973.11 | 21-OCT-11:09 | 19.08 | 12.94 |
November | 0.358399E+10 | 8587.39 | 04-NOV-06:02 | 16.10 | 15.06 | 0.786874E+09 | 973.11 | 04-NOV-13:00 | 17.80 | 17.48 |
December | 0.254425E+10 | 4860.88 | 01-DEC-07:05 | -3.8 | -4.7 | 0.750218E+09 | 973.12 | 13-DEC-15:39 | 17.57 | 16.89 |
Annual Sum or Average | 0.526711E+11 | 0.980784E+10 | ||||||||
Minimum of Months | 0.155055E+10 | 4672.96 | -3.8 | -5.0 | 0.669773E+09 | 973.10 | 17.57 | 12.15 | ||
Maximum of Months | 0.806707E+10 | 18219.41 | 22.80 | 17.45 | 0.905868E+09 | 973.16 | 30.40 | 23.74 |
Report: ZoneCoolingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 | 4.97 | 0.00 | 0.00 | 01-JAN-00:10 | 5.70 | 4.97 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 | 7.50 | 0.00 | 0.00 | 01-FEB-00:10 | 9.92 | 7.50 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.50 | 0.00 | 0.00 | 01-MAR-00:10 | 15.32 | 8.50 |
April | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.81 | 0.00 | 0.00 | 01-APR-00:10 | 12.05 | 7.81 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 | 0.00 | 0.00 | 01-MAY-00:10 | 16.68 | 16.68 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 | 18.59 | 0.00 | 0.00 | 01-JUN-00:10 | 20.93 | 18.59 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 | 21.38 | 0.00 | 0.00 | 01-JUL-00:10 | 22.28 | 21.38 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 21.87 | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 | 21.87 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 | 18.45 | 0.00 | 0.00 | 01-SEP-00:10 | 21.40 | 18.45 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 | 0.00 | 0.00 | 01-OCT-00:10 | 16.85 | 15.92 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.59 | 0.00 | 0.00 | 01-NOV-00:10 | 9.70 | 6.59 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 | 0.00 | 0.00 | 01-DEC-00:10 | 1.80 | 1.51 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 1.80 | 1.51 | 0.00 | 0.00 | 1.80 | 1.51 | ||
Maximum of Months | 0.00 | 0.00 | 25.13 | 21.87 | 0.00 | 0.00 | 25.13 | 21.87 |
Report: ZoneHeatingSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.412860E+10 | 50557.65 | 15-JAN-08:61 | -4.2 |
February | 0.227542E+10 | 50708.56 | 12-FEB-08:61 | -11.9 |
March | 0.148434E+09 | 30604.38 | 23-MAR-06:03 | 6.10 |
April | 82867584.17 | 4096.98 | 07-APR-06:03 | 2.80 |
May | 82649268.71 | 813.53 | 14-MAY-07:25 | 14.45 |
June | 45887933.93 | 1182.02 | 26-JUN-05:05 | 23.30 |
July | 34703146.40 | 1340.01 | 15-JUL-05:05 | 23.98 |
August | 27781244.95 | 1283.66 | 10-AUG-05:04 | 24.40 |
September | 62949112.80 | 1068.32 | 07-SEP-05:05 | 22.20 |
October | 83601364.16 | 827.58 | 05-OCT-06:00 | 11.10 |
November | 0.198747E+09 | 49294.12 | 22-NOV-06:02 | -3.3 |
December | 0.115286E+10 | 50381.24 | 04-DEC-06:01 | -2.9 |
Annual Sum or Average | 0.832450E+10 | |||
Minimum of Months | 27781244.95 | 813.53 | -11.9 | |
Maximum of Months | 0.412860E+10 | 50708.56 | 24.40 |
Report: ZoneHeatingSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.207020E+10 | 231992.89 | 16-JAN-08:61 | -2.6 |
February | 0.102812E+10 | 233752.59 | 12-FEB-08:61 | -11.9 |
March | 0.539438E+09 | 5199.57 | 06-MAR-06:33 | 2.97 |
April | 0.523143E+09 | 5199.88 | 30-APR-07:55 | 13.90 |
May | 0.470556E+09 | 5705.30 | 07-MAY-08:06 | 21.47 |
June | 0.239476E+09 | 7325.46 | 25-JUN-08:06 | 23.87 |
July | 0.252808E+09 | 8272.01 | 16-JUL-08:06 | 25.97 |
August | 0.252775E+09 | 7654.31 | 10-AUG-06:06 | 24.50 |
September | 0.318993E+09 | 7062.49 | 04-SEP-08:06 | 23.17 |
October | 0.520471E+09 | 5152.09 | 29-OCT-07:25 | 12.50 |
November | 0.524961E+09 | 5232.31 | 21-NOV-06:25 | -2.8 |
December | 0.598885E+09 | 75790.59 | 04-DEC-07:03 | -3.3 |
Annual Sum or Average | 0.733983E+10 | |||
Minimum of Months | 0.239476E+09 | 5152.09 | -11.9 | |
Maximum of Months | 0.207020E+10 | 233752.59 | 25.97 |
Report: ZoneHeatingSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.665332E+09 | 30635.05 | 09-JAN-05:01 | -2.2 |
February | 0.368005E+09 | 30881.33 | 12-FEB-08:61 | -11.9 |
March | 51671986.66 | 4936.45 | 23-MAR-06:03 | 6.10 |
April | 48327872.75 | 507.41 | 06-APR-05:23 | 0.55 |
May | 44029878.08 | 590.93 | 19-MAY-05:05 | 16.60 |
June | 19790416.31 | 927.91 | 14-JUN-05:05 | 21.70 |
July | 17511973.80 | 1052.65 | 16-JUL-08:06 | 25.97 |
August | 16686711.97 | 967.27 | 09-AUG-05:05 | 24.40 |
September | 20507095.64 | 1025.40 | 09-SEP-05:05 | 21.78 |
October | 44118447.79 | 606.82 | 11-OCT-05:07 | 18.72 |
November | 52314268.34 | 5752.02 | 22-NOV-07:03 | -3.2 |
December | 0.135489E+09 | 30575.22 | 26-DEC-06:01 | 3.30 |
Annual Sum or Average | 0.148378E+10 | |||
Minimum of Months | 16686711.97 | 507.41 | -11.9 | |
Maximum of Months | 0.665332E+09 | 30881.33 | 25.97 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.133831E+10 | 25108.03 | 09-JAN-05:01 | -2.2 |
February | 0.714263E+09 | 25214.00 | 12-FEB-07:01 | -12.7 |
March | 74446370.89 | 15142.46 | 23-MAR-06:03 | 6.10 |
April | 49300733.06 | 10623.37 | 06-APR-06:03 | 1.20 |
May | 38696539.32 | 385.97 | 11-MAY-06:00 | 7.80 |
June | 27333565.34 | 587.98 | 25-JUN-08:06 | 23.87 |
July | 17033943.99 | 659.67 | 15-JUL-06:06 | 24.40 |
August | 12055576.82 | 658.37 | 10-AUG-06:06 | 24.50 |
September | 26666679.37 | 587.14 | 09-SEP-05:05 | 21.78 |
October | 39969279.98 | 1187.81 | 26-OCT-06:07 | 2.20 |
November | 70090799.89 | 16263.23 | 22-NOV-06:02 | -3.3 |
December | 0.352709E+09 | 25086.95 | 04-DEC-06:01 | -2.9 |
Annual Sum or Average | 0.276088E+10 | |||
Minimum of Months | 12055576.82 | 385.97 | -12.7 | |
Maximum of Months | 0.133831E+10 | 25214.00 | 24.50 |
Report: ZoneHeatingSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.127873E+11 | 31951.39 | 07-JAN-18:00 | -5.0 |
February | 0.787640E+10 | 31905.64 | 11-FEB-18:00 | -5.0 |
March | 0.371892E+10 | 19337.19 | 22-MAR-11:10 | 4.40 |
April | 0.125372E+10 | 14911.18 | 05-APR-11:07 | 8.17 |
May | 0.175249E+09 | 4284.12 | 10-MAY-11:10 | 17.30 |
June | 5713522.82 | 1784.86 | 10-JUN-07:04 | 14.27 |
July | 58219148.62 | 2534.22 | 28-JUL-11:10 | 19.40 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 25.13 |
September | 0.151710E+09 | 3715.08 | 28-SEP-17:00 | 17.20 |
October | 0.187340E+10 | 13580.97 | 25-OCT-11:05 | 9.18 |
November | 0.378923E+10 | 19521.64 | 20-NOV-12:10 | 3.98 |
December | 0.829123E+10 | 23621.30 | 17-DEC-18:00 | 1.10 |
Annual Sum or Average | 0.399811E+11 | |||
Minimum of Months | 0.00 | 0.00 | -5.0 | |
Maximum of Months | 0.127873E+11 | 31951.39 | 25.13 |
Report: ZoneElectricSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.244735E+10 | 2030.36 | 02-JAN-09:09 | 0.421155E+10 | 2759.14 | 02-JAN-09:09 |
February | 0.222649E+10 | 2030.36 | 01-FEB-09:09 | 0.382086E+10 | 2759.14 | 01-FEB-09:09 |
March | 0.253900E+10 | 2030.36 | 01-MAR-09:09 | 0.431750E+10 | 2759.14 | 01-MAR-09:09 |
April | 0.239592E+10 | 2030.36 | 01-APR-09:09 | 0.410284E+10 | 2759.14 | 01-APR-09:09 |
May | 0.249318E+10 | 2030.36 | 01-MAY-08:09 | 0.426453E+10 | 2759.14 | 01-MAY-08:09 |
June | 0.245011E+10 | 2030.36 | 01-JUN-08:09 | 0.416961E+10 | 2759.14 | 01-JUN-08:09 |
July | 0.243899E+10 | 2030.36 | 01-JUL-09:09 | 0.419776E+10 | 2759.14 | 01-JUL-09:09 |
August | 0.253900E+10 | 2030.36 | 01-AUG-08:09 | 0.431750E+10 | 2759.14 | 01-AUG-08:09 |
September | 0.239592E+10 | 2030.36 | 01-SEP-08:09 | 0.410284E+10 | 2759.14 | 01-SEP-08:09 |
October | 0.244735E+10 | 2030.36 | 02-OCT-08:09 | 0.421155E+10 | 2759.14 | 02-OCT-08:09 |
November | 0.236682E+10 | 2030.36 | 01-NOV-08:09 | 0.407746E+10 | 2759.14 | 01-NOV-08:09 |
December | 0.243899E+10 | 2030.36 | 01-DEC-09:09 | 0.419776E+10 | 2759.14 | 01-DEC-09:09 |
Annual Sum or Average | 0.291791E+11 | 0.499918E+11 | ||||
Minimum of Months | 0.222649E+10 | 2030.36 | 0.382086E+10 | 2759.14 | ||
Maximum of Months | 0.253900E+10 | 2030.36 | 0.431750E+10 | 2759.14 |
Report: ZoneElectricSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.233290E+11 | 22187.24 | 02-JAN-15:30 | 0.710173E+10 | 4652.60 | 02-JAN-09:09 |
February | 0.208511E+11 | 22187.24 | 01-FEB-09:09 | 0.644293E+10 | 4652.60 | 01-FEB-09:09 |
March | 0.212588E+11 | 22187.24 | 01-MAR-17:30 | 0.728039E+10 | 4652.60 | 01-MAR-09:09 |
April | 0.186637E+11 | 22187.24 | 03-APR-08:09 | 0.691842E+10 | 4652.60 | 01-APR-09:09 |
May | 0.186804E+11 | 20338.30 | 05-MAY-16:49 | 0.719106E+10 | 4652.60 | 01-MAY-08:09 |
June | 0.180730E+11 | 20338.30 | 05-JUN-16:00 | 0.703101E+10 | 4652.60 | 01-JUN-08:09 |
July | 0.179573E+11 | 20338.30 | 11-JUL-16:00 | 0.707847E+10 | 4652.60 | 01-JUL-09:09 |
August | 0.186764E+11 | 20338.30 | 18-AUG-16:49 | 0.728039E+10 | 4652.60 | 01-AUG-08:09 |
September | 0.190535E+11 | 22187.24 | 02-SEP-16:49 | 0.691842E+10 | 4652.60 | 01-SEP-08:09 |
October | 0.224059E+11 | 22187.24 | 03-OCT-16:00 | 0.710173E+10 | 4652.60 | 02-OCT-08:09 |
November | 0.219885E+11 | 22187.24 | 01-NOV-08:09 | 0.687562E+10 | 4652.60 | 01-NOV-08:09 |
December | 0.232074E+11 | 22187.24 | 01-DEC-09:09 | 0.707847E+10 | 4652.60 | 01-DEC-09:09 |
Annual Sum or Average | 0.244145E+12 | 0.842987E+11 | ||||
Minimum of Months | 0.179573E+11 | 20338.30 | 0.644293E+10 | 4652.60 | ||
Maximum of Months | 0.233290E+11 | 22187.24 | 0.728039E+10 | 4652.60 |
Report: ZoneElectricSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.249582E+10 | 2090.65 | 02-JAN-09:09 | 0.445844E+10 | 2920.89 | 02-JAN-09:09 |
February | 0.227087E+10 | 2090.65 | 01-FEB-09:09 | 0.404485E+10 | 2920.89 | 01-FEB-09:09 |
March | 0.259032E+10 | 2090.65 | 01-MAR-09:09 | 0.457061E+10 | 2920.89 | 01-MAR-09:09 |
April | 0.244398E+10 | 2090.65 | 01-APR-09:09 | 0.434336E+10 | 2920.89 | 01-APR-09:09 |
May | 0.254307E+10 | 2090.65 | 01-MAY-08:09 | 0.451452E+10 | 2920.89 | 01-MAY-08:09 |
June | 0.249959E+10 | 2090.65 | 01-JUN-08:09 | 0.441405E+10 | 2920.89 | 01-JUN-08:09 |
July | 0.248746E+10 | 2090.65 | 01-JUL-09:09 | 0.444384E+10 | 2920.89 | 01-JUL-09:09 |
August | 0.259032E+10 | 2090.65 | 01-AUG-08:09 | 0.457061E+10 | 2920.89 | 01-AUG-08:09 |
September | 0.244398E+10 | 2090.65 | 01-SEP-08:09 | 0.434336E+10 | 2920.89 | 01-SEP-08:09 |
October | 0.249582E+10 | 2090.65 | 02-OCT-08:09 | 0.445844E+10 | 2920.89 | 02-OCT-08:09 |
November | 0.241345E+10 | 2090.65 | 01-NOV-08:09 | 0.431649E+10 | 2920.89 | 01-NOV-08:09 |
December | 0.248746E+10 | 2090.65 | 01-DEC-09:09 | 0.444384E+10 | 2920.89 | 01-DEC-09:09 |
Annual Sum or Average | 0.297621E+11 | 0.529224E+11 | ||||
Minimum of Months | 0.227087E+10 | 2090.65 | 0.404485E+10 | 2920.89 | ||
Maximum of Months | 0.259032E+10 | 2090.65 | 0.457061E+10 | 2920.89 |
Report: ZoneElectricSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.249582E+10 | 2090.65 | 02-JAN-09:09 | 0.669181E+09 | 438.40 | 02-JAN-09:09 |
February | 0.227087E+10 | 2090.65 | 01-FEB-09:09 | 0.607103E+09 | 438.40 | 01-FEB-09:09 |
March | 0.259032E+10 | 2090.65 | 01-MAR-09:09 | 0.686016E+09 | 438.40 | 01-MAR-09:09 |
April | 0.244398E+10 | 2090.65 | 01-APR-09:09 | 0.651908E+09 | 438.40 | 01-APR-09:09 |
May | 0.254307E+10 | 2090.65 | 01-MAY-08:09 | 0.677598E+09 | 438.40 | 01-MAY-08:09 |
June | 0.249959E+10 | 2090.65 | 01-JUN-08:09 | 0.662517E+09 | 438.40 | 01-JUN-08:09 |
July | 0.248746E+10 | 2090.65 | 01-JUL-09:09 | 0.666989E+09 | 438.40 | 01-JUL-09:09 |
August | 0.259032E+10 | 2090.65 | 01-AUG-08:09 | 0.686016E+09 | 438.40 | 01-AUG-08:09 |
September | 0.244398E+10 | 2090.65 | 01-SEP-08:09 | 0.651908E+09 | 438.40 | 01-SEP-08:09 |
October | 0.249582E+10 | 2090.65 | 02-OCT-08:09 | 0.669181E+09 | 438.40 | 02-OCT-08:09 |
November | 0.241345E+10 | 2090.65 | 01-NOV-08:09 | 0.647874E+09 | 438.40 | 01-NOV-08:09 |
December | 0.248746E+10 | 2090.65 | 01-DEC-09:09 | 0.666989E+09 | 438.40 | 01-DEC-09:09 |
Annual Sum or Average | 0.297621E+11 | 0.794328E+10 | ||||
Minimum of Months | 0.227087E+10 | 2090.65 | 0.607103E+09 | 438.40 | ||
Maximum of Months | 0.259032E+10 | 2090.65 | 0.686016E+09 | 438.40 |
Report: ZoneElectricSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.112411E+09 | 94.16 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.102280E+09 | 94.16 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.116668E+09 | 94.16 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.110076E+09 | 94.16 | 01-APR-09:09 | 0.00 | 0.00 |
May | 0.114539E+09 | 94.16 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.112581E+09 | 94.16 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.112035E+09 | 94.16 | 01-JUL-09:09 | 0.00 | 0.00 |
August | 0.116668E+09 | 94.16 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.110076E+09 | 94.16 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.112411E+09 | 94.16 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.108701E+09 | 94.16 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.112035E+09 | 94.16 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.134048E+10 | ||||
Minimum of Months | 0.102280E+09 | 94.16 | 0.00 | 0.00 | |
Maximum of Months | 0.116668E+09 | 94.16 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.524694E+10 | 0.244735E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220434E+10 |
February | 0.479114E+10 | 0.222649E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 493766.14 | 0.190146E+10 |
March | 0.548013E+10 | 0.253900E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4813299.15 | 0.126194E+10 |
April | 0.518069E+10 | 0.239592E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12455061.60 | 0.787731E+09 |
May | 0.536353E+10 | 0.249318E+10 | 0.426453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37591571.95 | 0.517629E+09 |
June | 0.528933E+10 | 0.245011E+10 | 0.416961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141161E+09 | 0.273854E+09 |
July | 0.525489E+10 | 0.243899E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145180E+09 | 0.179605E+09 |
August | 0.548013E+10 | 0.253900E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151630E+09 | 0.126593E+09 |
September | 0.518069E+10 | 0.239592E+10 | 0.410284E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44118173.50 | 0.284658E+09 |
October | 0.524694E+10 | 0.244735E+10 | 0.421155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8494033.58 | 0.956872E+09 |
November | 0.504819E+10 | 0.236682E+10 | 0.407746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 53828.24 | 0.134216E+10 |
December | 0.525489E+10 | 0.243899E+10 | 0.419776E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200110E+10 |
Annual Sum or Average | 0.628175E+11 | 0.291791E+11 | 0.499918E+11 | 0.545990E+09 | 0.118379E+11 | ||||
Minimum of Months | 0.479114E+10 | 0.222649E+10 | 0.382086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126593E+09 |
Maximum of Months | 0.548013E+10 | 0.253900E+10 | 0.431750E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151630E+09 | 0.220434E+10 |
Report: SpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.221054E+11 | 0.233290E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202047E+10 |
February | 0.201852E+11 | 0.208511E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 398221.83 | 0.178245E+10 |
March | 0.230879E+11 | 0.212588E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3936989.91 | 0.120420E+10 |
April | 0.218263E+11 | 0.186637E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10170695.47 | 0.727064E+09 |
May | 0.225967E+11 | 0.186804E+11 | 0.719106E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30608932.23 | 0.466972E+09 |
June | 0.222841E+11 | 0.180730E+11 | 0.703101E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115337E+09 | 0.235246E+09 |
July | 0.221389E+11 | 0.179573E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.119539E+09 | 0.151028E+09 |
August | 0.230879E+11 | 0.186764E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124981E+09 | 0.104152E+09 |
September | 0.218263E+11 | 0.190535E+11 | 0.691842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 36072421.19 | 0.245407E+09 |
October | 0.221054E+11 | 0.224059E+11 | 0.710173E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6952427.66 | 0.850288E+09 |
November | 0.212681E+11 | 0.219885E+11 | 0.687562E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 44077.04 | 0.123413E+10 |
December | 0.221389E+11 | 0.232074E+11 | 0.707847E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.188698E+10 |
Annual Sum or Average | 0.264651E+12 | 0.244145E+12 | 0.842987E+11 | 0.448040E+09 | 0.109084E+11 | ||||
Minimum of Months | 0.201852E+11 | 0.179573E+11 | 0.644293E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104152E+09 |
Maximum of Months | 0.230879E+11 | 0.233290E+11 | 0.728039E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.124981E+09 | 0.202047E+10 |
Report: SpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.249582E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101739E+10 |
February | 0.190200E+10 | 0.227087E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 210911.60 | 0.885356E+09 |
March | 0.217552E+10 | 0.259032E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2082219.09 | 0.609201E+09 |
April | 0.205665E+10 | 0.244398E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5377011.75 | 0.367658E+09 |
May | 0.212923E+10 | 0.254307E+10 | 0.451452E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16057347.69 | 0.241749E+09 |
June | 0.209978E+10 | 0.249959E+10 | 0.441405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 59735411.47 | 0.133488E+09 |
July | 0.208610E+10 | 0.248746E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 59495993.98 | 90489221.78 |
August | 0.217552E+10 | 0.259032E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61815935.77 | 73852554.36 |
September | 0.205665E+10 | 0.244398E+10 | 0.434336E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18536246.72 | 0.140670E+09 |
October | 0.208295E+10 | 0.249582E+10 | 0.445844E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3679990.67 | 0.452794E+09 |
November | 0.200405E+10 | 0.241345E+10 | 0.431649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 23364.39 | 0.641222E+09 |
December | 0.208610E+10 | 0.248746E+10 | 0.444384E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.944116E+09 |
Annual Sum or Average | 0.249375E+11 | 0.297621E+11 | 0.529224E+11 | 0.227014E+09 | 0.559799E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.227087E+10 | 0.404485E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 73852554.36 |
Maximum of Months | 0.217552E+10 | 0.259032E+10 | 0.457061E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 61815935.77 | 0.101739E+10 |
Report: SpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.208295E+10 | 0.249582E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.974213E+09 |
February | 0.190200E+10 | 0.227087E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 210883.58 | 0.840918E+09 |
March | 0.217552E+10 | 0.259032E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 2083042.81 | 0.564604E+09 |
April | 0.205665E+10 | 0.244398E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5385445.17 | 0.338583E+09 |
May | 0.212923E+10 | 0.254307E+10 | 0.677598E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 16180845.08 | 0.219498E+09 |
June | 0.209978E+10 | 0.249959E+10 | 0.662517E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 60637422.13 | 0.115234E+09 |
July | 0.208610E+10 | 0.248746E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 61654931.78 | 76571129.93 |
August | 0.217552E+10 | 0.259032E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 63776095.16 | 58536481.61 |
September | 0.205665E+10 | 0.244398E+10 | 0.651908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 18764374.66 | 0.126120E+09 |
October | 0.208295E+10 | 0.249582E+10 | 0.669181E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3680153.01 | 0.423261E+09 |
November | 0.200405E+10 | 0.241345E+10 | 0.647874E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 23358.13 | 0.603362E+09 |
December | 0.208610E+10 | 0.248746E+10 | 0.666989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.889515E+09 |
Annual Sum or Average | 0.249375E+11 | 0.297621E+11 | 0.794328E+10 | 0.232397E+09 | 0.523042E+10 | ||||
Minimum of Months | 0.190200E+10 | 0.227087E+10 | 0.607103E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58536481.61 |
Maximum of Months | 0.217552E+10 | 0.259032E+10 | 0.686016E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 63776095.16 | 0.974213E+09 |
Report: SpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.112411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128450E+11 |
February | 0.00 | 0.102280E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.807946E+10 |
March | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32838.83 | 0.421727E+10 |
April | 0.00 | 0.110076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8588135.91 | 0.155681E+10 |
May | 0.00 | 0.114539E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61229476.55 | 0.429387E+09 |
June | 0.00 | 0.112581E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.255578E+09 | 0.109796E+09 |
July | 0.00 | 0.112035E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304739E+09 | 0.169107E+09 |
August | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.219345E+09 | 93930434.29 |
September | 0.00 | 0.110076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24529299.30 | 0.444782E+09 |
October | 0.00 | 0.112411E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41643.49 | 0.254336E+10 |
November | 0.00 | 0.108701E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.447714E+10 |
December | 0.00 | 0.112035E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.871890E+10 |
Annual Sum or Average | 0.00 | 0.134048E+10 | 0.874082E+09 | 0.436849E+11 | |||||
Minimum of Months | 0.00 | 0.102280E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93930434.29 |
Maximum of Months | 0.00 | 0.116668E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.304739E+09 | 0.128450E+11 |
Report: PeakSpaceGainsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 5888.82 | 02-JAN-15:09 | 2030.36 | 02-JAN-09:09 | 2759.14 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4018.57 | 07-JAN-05:05 |
February | 5888.82 | 01-FEB-15:09 | 2030.36 | 01-FEB-09:09 | 2759.14 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 57.82 | 28-FEB-15:00 | 5574.30 | 12-FEB-01:00 |
March | 5888.82 | 01-MAR-15:09 | 2030.36 | 01-MAR-09:09 | 2759.14 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 135.20 | 30-MAR-16:00 | 3250.75 | 22-MAR-03:00 |
April | 5888.82 | 01-APR-10:09 | 2030.36 | 01-APR-09:09 | 2759.14 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 105.08 | 04-APR-15:00 | 1782.94 | 05-APR-05:00 |
May | 5888.82 | 01-MAY-14:09 | 2030.36 | 01-MAY-08:09 | 2759.14 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 335.05 | 29-MAY-18:03 | 1504.57 | 10-MAY-04:00 |
June | 5888.82 | 01-JUN-14:09 | 2030.36 | 01-JUN-08:09 | 2759.14 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 517.20 | 11-JUN-18:03 | 1119.53 | 07-JUN-03:00 |
July | 5888.82 | 01-JUL-10:09 | 2030.36 | 01-JUL-09:09 | 2759.14 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 520.35 | 09-JUL-18:03 | 789.56 | 28-JUL-22:00 |
August | 5888.82 | 01-AUG-14:09 | 2030.36 | 01-AUG-08:09 | 2759.14 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 714.67 | 18-AUG-20:03 | 553.31 | 25-AUG-05:00 |
September | 5888.82 | 01-SEP-14:09 | 2030.36 | 01-SEP-08:09 | 2759.14 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 283.58 | 03-SEP-18:03 | 1076.28 | 29-SEP-05:00 |
October | 5888.82 | 02-OCT-14:09 | 2030.36 | 02-OCT-08:09 | 2759.14 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 106.92 | 11-OCT-14:00 | 2095.42 | 28-OCT-04:00 |
November | 5888.82 | 01-NOV-14:09 | 2030.36 | 01-NOV-08:09 | 2759.14 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 19.94 | 19-NOV-14:55 | 3224.69 | 30-NOV-21:03 |
December | 5888.82 | 01-DEC-15:09 | 2030.36 | 01-DEC-09:09 | 2759.14 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5194.98 | 17-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 553.31 | |||||
Maximum of Months | 5888.82 | 2030.36 | 2759.14 | 0.00 | 0.00 | 0.00 | 0.00 | 714.67 | 5574.30 |
Report: PeakSpaceGainsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 24809.68 | 02-JAN-15:09 | 22187.24 | 02-JAN-15:30 | 4652.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 3750.48 | 26-JAN-02:00 |
February | 24809.68 | 01-FEB-15:09 | 22187.24 | 01-FEB-09:09 | 4652.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 47.33 | 28-FEB-15:00 | 5149.08 | 12-FEB-01:00 |
March | 24809.68 | 01-MAR-15:09 | 22187.24 | 01-MAR-17:30 | 4652.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 110.67 | 30-MAR-16:00 | 3278.24 | 22-MAR-03:00 |
April | 24809.68 | 01-APR-10:09 | 22187.24 | 03-APR-08:09 | 4652.60 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 86.02 | 04-APR-15:00 | 1669.38 | 05-APR-05:00 |
May | 24809.68 | 01-MAY-14:09 | 20338.30 | 05-MAY-16:49 | 4652.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 273.22 | 29-MAY-18:03 | 1353.83 | 10-MAY-04:00 |
June | 24809.68 | 01-JUN-14:09 | 20338.30 | 05-JUN-16:00 | 4652.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 422.85 | 11-JUN-18:03 | 974.16 | 07-JUN-03:00 |
July | 24809.68 | 01-JUL-10:09 | 20338.30 | 11-JUL-16:00 | 4652.60 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 427.21 | 09-JUL-18:03 | 703.99 | 28-JUL-22:00 |
August | 24809.68 | 01-AUG-14:09 | 20338.30 | 18-AUG-16:49 | 4652.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 587.60 | 18-AUG-20:03 | 466.21 | 25-AUG-05:00 |
September | 24809.68 | 01-SEP-14:09 | 22187.24 | 02-SEP-16:49 | 4652.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 233.35 | 03-SEP-18:03 | 943.63 | 29-SEP-05:00 |
October | 24809.68 | 02-OCT-14:09 | 22187.24 | 03-OCT-16:00 | 4652.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 87.54 | 11-OCT-14:00 | 1994.00 | 28-OCT-04:00 |
November | 24809.68 | 01-NOV-14:09 | 22187.24 | 01-NOV-08:09 | 4652.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.32 | 19-NOV-14:55 | 3039.92 | 30-NOV-21:03 |
December | 24809.68 | 01-DEC-15:09 | 22187.24 | 01-DEC-09:09 | 4652.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 5018.94 | 17-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 24809.68 | 20338.30 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 466.21 | |||||
Maximum of Months | 24809.68 | 22187.24 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 587.60 | 5149.08 |
Report: PeakSpaceGainsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2090.65 | 02-JAN-09:09 | 2920.89 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1834.81 | 26-JAN-02:00 |
February | 2337.76 | 01-FEB-15:09 | 2090.65 | 01-FEB-09:09 | 2920.89 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.07 | 28-FEB-15:00 | 2434.08 | 12-FEB-01:00 |
March | 2337.76 | 01-MAR-15:09 | 2090.65 | 01-MAR-09:09 | 2920.89 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 58.59 | 30-MAR-16:00 | 1518.25 | 22-MAR-03:00 |
April | 2337.76 | 01-APR-10:09 | 2090.65 | 01-APR-09:09 | 2920.89 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 45.54 | 04-APR-15:00 | 802.89 | 05-APR-05:00 |
May | 2337.76 | 01-MAY-14:09 | 2090.65 | 01-MAY-08:09 | 2920.89 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 141.39 | 29-MAY-18:03 | 664.24 | 10-MAY-04:00 |
June | 2337.76 | 01-JUN-14:09 | 2090.65 | 01-JUN-08:09 | 2920.89 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 220.54 | 11-JUN-18:03 | 508.14 | 07-JUN-03:00 |
July | 2337.76 | 01-JUL-10:09 | 2090.65 | 01-JUL-09:09 | 2920.89 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 222.45 | 09-JUL-18:03 | 366.50 | 28-JUL-22:00 |
August | 2337.76 | 01-AUG-14:09 | 2090.65 | 01-AUG-08:09 | 2920.89 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 303.31 | 18-AUG-20:03 | 271.42 | 31-AUG-05:00 |
September | 2337.76 | 01-SEP-14:09 | 2090.65 | 01-SEP-08:09 | 2920.89 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 118.16 | 03-SEP-18:03 | 472.67 | 29-SEP-05:00 |
October | 2337.76 | 02-OCT-14:09 | 2090.65 | 02-OCT-08:09 | 2920.89 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 46.35 | 11-OCT-14:00 | 1008.67 | 28-OCT-04:00 |
November | 2337.76 | 01-NOV-14:09 | 2090.65 | 01-NOV-08:09 | 2920.89 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8.65 | 19-NOV-15:00 | 1469.40 | 07-NOV-02:00 |
December | 2337.76 | 01-DEC-15:09 | 2090.65 | 01-DEC-09:09 | 2920.89 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2331.43 | 17-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.42 | |||||
Maximum of Months | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 303.31 | 2434.08 |
Report: PeakSpaceGainsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2337.76 | 02-JAN-15:09 | 2090.65 | 02-JAN-09:09 | 438.40 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1741.50 | 26-JAN-02:00 |
February | 2337.76 | 01-FEB-15:09 | 2090.65 | 01-FEB-09:09 | 438.40 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 25.06 | 28-FEB-15:00 | 2376.52 | 12-FEB-01:00 |
March | 2337.76 | 01-MAR-15:09 | 2090.65 | 01-MAR-09:09 | 438.40 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 58.58 | 30-MAR-16:00 | 1401.73 | 22-MAR-03:00 |
April | 2337.76 | 01-APR-10:09 | 2090.65 | 01-APR-09:09 | 438.40 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 45.54 | 04-APR-15:00 | 745.48 | 05-APR-05:00 |
May | 2337.76 | 01-MAY-14:09 | 2090.65 | 01-MAY-08:09 | 438.40 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 143.22 | 29-MAY-18:03 | 630.77 | 10-MAY-04:00 |
June | 2337.76 | 01-JUN-14:09 | 2090.65 | 01-JUN-08:09 | 438.40 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 222.26 | 11-JUN-18:03 | 470.76 | 07-JUN-03:00 |
July | 2337.76 | 01-JUL-10:09 | 2090.65 | 01-JUL-09:09 | 438.40 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 223.62 | 09-JUL-18:03 | 332.60 | 28-JUL-22:00 |
August | 2337.76 | 01-AUG-14:09 | 2090.65 | 01-AUG-08:09 | 438.40 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 306.08 | 18-AUG-20:03 | 234.12 | 25-AUG-05:00 |
September | 2337.76 | 01-SEP-14:09 | 2090.65 | 01-SEP-08:09 | 438.40 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 120.61 | 03-SEP-18:03 | 444.27 | 29-SEP-05:00 |
October | 2337.76 | 02-OCT-14:09 | 2090.65 | 02-OCT-08:09 | 438.40 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 46.35 | 11-OCT-14:00 | 950.56 | 28-OCT-04:00 |
November | 2337.76 | 01-NOV-14:09 | 2090.65 | 01-NOV-08:09 | 438.40 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8.64 | 19-NOV-15:00 | 1405.73 | 07-NOV-02:00 |
December | 2337.76 | 01-DEC-15:09 | 2090.65 | 01-DEC-09:09 | 438.40 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2225.11 | 17-DEC-04:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 234.12 | |||||
Maximum of Months | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 306.08 | 2376.52 |
Report: PeakSpaceGainsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 01-JAN-00:10 | 94.16 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 31574.78 | 07-JAN-17:00 |
February | 0.00 | 01-FEB-00:10 | 94.16 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 31804.20 | 11-FEB-18:00 |
March | 0.00 | 01-MAR-00:10 | 94.16 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.62 | 28-MAR-17:00 | 19317.84 | 22-MAR-11:10 |
April | 0.00 | 01-APR-00:10 | 94.16 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 232.80 | 12-APR-14:00 | 15586.82 | 05-APR-11:03 |
May | 0.00 | 01-MAY-00:10 | 94.16 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 716.47 | 30-MAY-11:03 | 4693.22 | 10-MAY-11:10 |
June | 0.00 | 01-JUN-00:10 | 94.16 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1723.44 | 06-JUN-11:02 | 1482.99 | 07-JUN-11:02 |
July | 0.00 | 01-JUL-00:10 | 94.16 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2270.30 | 08-JUL-11:01 | 3119.91 | 28-JUL-11:10 |
August | 0.00 | 01-AUG-00:10 | 94.16 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1814.74 | 01-AUG-11:02 | 1242.42 | 08-AUG-16:53 |
September | 0.00 | 01-SEP-00:10 | 94.16 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 441.60 | 09-SEP-11:05 | 4358.16 | 28-SEP-17:00 |
October | 0.00 | 01-OCT-00:10 | 94.16 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.81 | 10-OCT-16:00 | 14238.03 | 25-OCT-11:05 |
November | 0.00 | 01-NOV-00:10 | 94.16 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 19905.16 | 20-NOV-12:10 |
December | 0.00 | 01-DEC-00:10 | 94.16 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 23756.92 | 17-DEC-18:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 94.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1242.42 | ||||
Maximum of Months | 0.00 | 94.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2270.30 | 31804.20 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6571.00 | 26-JAN-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 706.08 |
February | 7121.12 | 03-FEB-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 712.36 |
March | 20044.78 | 31-MAR-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 209.91 |
April | 24150.23 | 19-APR-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.81 |
May | 35450.34 | 17-MAY-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86.54 |
June | 38261.13 | 10-JUN-06:02 | 3680.51 | 1127.98 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 132.31 |
July | 29624.20 | 03-JUL-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 65.55 |
August | 28523.97 | 26-AUG-06:02 | 3680.51 | 1127.98 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.51 |
September | 39069.87 | 14-SEP-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 193.20 |
October | 28924.59 | 11-OCT-06:02 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.45 |
November | 19065.28 | 04-NOV-06:02 | 3680.51 | 1127.98 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.85 |
December | 6570.41 | 18-DEC-07:05 | 2944.41 | 1804.76 | 4905.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 495.34 |
Annual Sum or Average | |||||||||||
Minimum of Months | 6570.41 | 2944.41 | 1127.98 | 4598.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.51 | |
Maximum of Months | 39069.87 | 3680.51 | 2255.95 | 6131.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 712.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 17136.86 | 20-JAN-16:00 | 24809.68 | 20338.30 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 169.08 |
February | 29440.71 | 28-FEB-16:00 | 24809.68 | 16640.43 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.26 |
March | 139950.59 | 31-MAR-06:02 | 15506.05 | 24652.49 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 191.48 |
April | 173791.09 | 15-APR-06:03 | 12404.84 | 9860.99 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.41 |
May | 163342.17 | 14-MAY-08:62 | 12404.84 | 6574.00 | 6203.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.39 |
June | 198669.53 | 08-JUN-06:02 | 15506.05 | 24652.49 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.37 |
July | 134122.89 | 03-JUL-06:02 | 15506.05 | 24652.49 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 53.08 |
August | 136758.65 | 26-AUG-06:02 | 15506.05 | 12326.24 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 43.32 |
September | 175824.03 | 14-SEP-06:02 | 15506.05 | 24652.49 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.38 |
October | 218329.37 | 12-OCT-06:02 | 15506.05 | 24652.49 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 219.24 |
November | 140462.66 | 04-NOV-06:02 | 15506.05 | 12326.24 | 7754.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 93.10 |
December | 114098.33 | 13-DEC-07:03 | 12404.84 | 19721.99 | 8271.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.18 |
Annual Sum or Average | |||||||||||
Minimum of Months | 17136.86 | 12404.84 | 6574.00 | 4652.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.41 | |
Maximum of Months | 218329.37 | 24809.68 | 24652.49 | 10339.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 219.24 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5352.39 | 27-JAN-07:05 | 1168.88 | 1858.36 | 5192.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 300.47 |
February | 7196.27 | 28-FEB-15:40 | 2337.76 | 2090.65 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 |
March | 18808.71 | 31-MAR-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 99.12 |
April | 23126.81 | 18-APR-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.91 |
May | 21934.73 | 17-MAY-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.62 |
June | 22706.39 | 07-JUN-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 114.25 |
July | 17737.40 | 03-JUL-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.95 |
August | 17572.51 | 26-AUG-06:02 | 1461.10 | 1161.47 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.39 |
September | 24040.17 | 14-SEP-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 85.59 |
October | 26339.62 | 12-OCT-06:02 | 1461.10 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 115.98 |
November | 19084.74 | 04-NOV-06:02 | 1461.10 | 1161.47 | 4868.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 47.02 |
December | 16469.14 | 13-DEC-07:03 | 1168.88 | 1858.36 | 5192.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.53 |
Annual Sum or Average | |||||||||||
Minimum of Months | 5352.39 | 1168.88 | 1161.47 | 2920.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 | |
Maximum of Months | 26339.62 | 2337.76 | 2322.95 | 6490.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 300.47 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4672.96 | 15-JAN-09:05 | 1168.88 | 929.18 | 584.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 237.18 |
February | 4982.55 | 27-FEB-16:00 | 2337.76 | 2090.65 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11747.14 | 31-MAR-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 91.20 |
April | 9352.86 | 18-APR-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 58.88 |
May | 15569.76 | 19-MAY-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.84 |
June | 16811.25 | 07-JUN-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 110.90 |
July | 14229.78 | 03-JUL-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.07 |
August | 13878.94 | 26-AUG-06:02 | 1461.10 | 1161.47 | 730.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.58 |
September | 18219.41 | 15-SEP-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 16141.89 | 10-OCT-06:02 | 1461.10 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 44.09 |
November | 8587.39 | 04-NOV-06:02 | 1461.10 | 1161.47 | 730.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.89 |
December | 4860.88 | 01-DEC-07:05 | 1168.88 | 1858.36 | 779.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 235.26 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4672.96 | 1168.88 | 929.18 | 438.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18219.41 | 2337.76 | 2322.95 | 974.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 237.18 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.77 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.49 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 52.41 |
April | 0.00 | 01-APR-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.23 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.17 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.44 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.74 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.47 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.59 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.47 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.40 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.79 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.47 | |
Maximum of Months | 0.00 | 0.00 | 5.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.79 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.702830E+11 | 58880.75 | 19-JAN-17:00 | 0.438796E+11 | 132913.03 | 09-JAN-07:10 |
February | 0.635386E+11 | 59093.10 | 28-FEB-17:10 | 0.266379E+11 | 134676.23 | 12-FEB-09:09 |
March | 0.716860E+11 | 67879.32 | 30-MAR-16:40 | 0.117102E+11 | 29142.80 | 23-MAR-06:10 |
April | 0.727430E+11 | 68544.19 | 17-APR-16:19 | 0.859091E+10 | 19163.95 | 05-APR-11:30 |
May | 0.850791E+11 | 73598.57 | 19-MAY-16:49 | 0.768513E+10 | 6860.53 | 10-MAY-11:20 |
June | 0.949475E+11 | 76994.28 | 12-JUN-15:50 | 0.727462E+10 | 4889.68 | 01-JUN-11:20 |
July | 0.101397E+12 | 84146.97 | 07-JUL-15:50 | 0.734999E+10 | 4851.45 | 03-JUL-11:20 |
August | 0.106019E+12 | 82934.17 | 18-AUG-16:49 | 0.740522E+10 | 4849.74 | 31-AUG-11:20 |
September | 0.892653E+11 | 79982.82 | 07-SEP-16:30 | 0.726481E+10 | 6694.08 | 28-SEP-16:49 |
October | 0.783795E+11 | 75175.00 | 10-OCT-15:50 | 0.884470E+10 | 17938.54 | 25-OCT-11:20 |
November | 0.694983E+11 | 64635.84 | 27-NOV-17:30 | 0.111908E+11 | 39410.07 | 22-NOV-07:10 |
December | 0.710811E+11 | 59308.81 | 12-DEC-15:00 | 0.218195E+11 | 86916.80 | 04-DEC-07:10 |
Annual Sum or Average | 0.973917E+12 | 0.169653E+12 | ||||
Minimum of Months | 0.635386E+11 | 58880.75 | 0.726481E+10 | 4849.74 | ||
Maximum of Months | 0.106019E+12 | 84146.97 | 0.438796E+11 | 134676.23 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [J] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.308804E+11 | 0.607781E+10 | 0.164409E+11 | 0.00 | 0.143923E+11 | 0.00 | 0.00 | 0.479236E+09 | 0.00 | 0.00 | 0.201231E+10 | 0.00 | 0.00 |
February | 0.277216E+11 | 0.513631E+10 | 0.149157E+11 | 0.00 | 0.124606E+11 | 0.00 | 0.00 | 0.186912E+10 | 0.00 | 0.00 | 0.143519E+10 | 0.00 | 0.00 |
March | 0.290951E+11 | 0.517373E+10 | 0.168545E+11 | 0.00 | 0.130402E+11 | 0.00 | 0.00 | 0.641096E+10 | 0.00 | 0.00 | 0.111157E+10 | 0.00 | 0.00 |
April | 0.260577E+11 | 0.449462E+10 | 0.160165E+11 | 0.00 | 0.116369E+11 | 0.00 | 0.00 | 0.134707E+11 | 0.00 | 0.00 | 0.106665E+10 | 0.00 | 0.00 |
May | 0.263743E+11 | 0.419843E+10 | 0.166477E+11 | 0.00 | 0.113897E+11 | 0.00 | 0.00 | 0.248346E+11 | 0.00 | 0.00 | 0.163447E+10 | 0.00 | 0.00 |
June | 0.256348E+11 | 0.386724E+10 | 0.162772E+11 | 0.00 | 0.110330E+11 | 0.00 | 0.00 | 0.362780E+11 | 0.00 | 0.00 | 0.185723E+10 | 0.00 | 0.00 |
July | 0.254833E+11 | 0.406966E+10 | 0.163871E+11 | 0.00 | 0.114602E+11 | 0.00 | 0.00 | 0.418962E+11 | 0.00 | 0.00 | 0.210039E+10 | 0.00 | 0.00 |
August | 0.265127E+11 | 0.444225E+10 | 0.168545E+11 | 0.00 | 0.116796E+11 | 0.00 | 0.00 | 0.443941E+11 | 0.00 | 0.00 | 0.213600E+10 | 0.00 | 0.00 |
September | 0.264475E+11 | 0.478502E+10 | 0.160165E+11 | 0.00 | 0.110682E+11 | 0.00 | 0.00 | 0.292499E+11 | 0.00 | 0.00 | 0.169819E+10 | 0.00 | 0.00 |
October | 0.299573E+11 | 0.547509E+10 | 0.164409E+11 | 0.00 | 0.121517E+11 | 0.00 | 0.00 | 0.132325E+11 | 0.00 | 0.00 | 0.112196E+10 | 0.00 | 0.00 |
November | 0.292910E+11 | 0.576306E+10 | 0.159174E+11 | 0.00 | 0.124301E+11 | 0.00 | 0.00 | 0.492302E+10 | 0.00 | 0.00 | 0.117365E+10 | 0.00 | 0.00 |
December | 0.307333E+11 | 0.620383E+10 | 0.163871E+11 | 0.00 | 0.137477E+11 | 0.00 | 0.00 | 0.215685E+10 | 0.00 | 0.00 | 0.185235E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.334189E+12 | 0.596871E+11 | 0.195156E+12 | 0.146490E+12 | 0.00 | 0.219195E+12 | 0.192000E+11 | ||||||
Minimum of Months | 0.254833E+11 | 0.386724E+10 | 0.149157E+11 | 0.00 | 0.110330E+11 | 0.00 | 0.00 | 0.479236E+09 | 0.00 | 0.00 | 0.106665E+10 | 0.00 | 0.00 |
Maximum of Months | 0.308804E+11 | 0.620383E+10 | 0.168545E+11 | 0.00 | 0.143923E+11 | 0.00 | 0.00 | 0.443941E+11 | 0.00 | 0.00 | 0.213600E+10 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [J] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.357569E+11 | 0.00 | 0.812274E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.192873E+11 | 0.00 | 0.735065E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.361833E+10 | 0.00 | 0.809187E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.973881E+09 | 0.00 | 0.761703E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 15001236.22 | 0.00 | 0.767012E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.727462E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.734999E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.740522E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 37530262.63 | 0.00 | 0.722728E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.123243E+10 | 0.00 | 0.761227E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.363306E+10 | 0.00 | 0.755770E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.138085E+11 | 0.00 | 0.801095E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.783629E+11 | 0.912904E+11 | |||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.722728E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.357569E+11 | 0.00 | 0.812274E+10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 28493.07 | 02-JAN-15:30 | 4566.05 | 01-JAN-06:10 | 10771.04 | 02-JAN-09:09 | 0.00 | 11923.34 | 09-JAN-07:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 28493.07 | 01-FEB-09:09 | 4566.05 | 01-FEB-06:10 | 10771.04 | 01-FEB-09:09 | 0.00 | 11787.70 | 12-FEB-09:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 28493.07 | 01-MAR-17:30 | 4566.05 | 01-MAR-06:10 | 10771.04 | 01-MAR-09:09 | 0.00 | 9255.75 | 19-MAR-08:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 28493.07 | 03-APR-08:09 | 4566.05 | 01-APR-05:10 | 10771.04 | 01-APR-09:09 | 0.00 | 10292.84 | 23-APR-08:09 | 0.00 | 0.00 | 01-APR-00:10 |
May | 26644.13 | 05-MAY-16:49 | 4566.05 | 01-MAY-05:10 | 10771.04 | 01-MAY-08:09 | 0.00 | 10482.57 | 31-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 26644.13 | 05-JUN-16:00 | 4566.05 | 01-JUN-05:10 | 10771.04 | 01-JUN-08:09 | 0.00 | 10988.46 | 26-JUN-06:10 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 26644.13 | 11-JUL-16:00 | 4566.05 | 01-JUL-05:10 | 10771.04 | 01-JUL-09:09 | 0.00 | 11098.90 | 27-JUL-06:10 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 26644.13 | 18-AUG-16:49 | 4566.05 | 01-AUG-05:10 | 10771.04 | 01-AUG-08:09 | 0.00 | 11321.19 | 20-AUG-08:09 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 28493.07 | 02-SEP-16:49 | 4566.05 | 01-SEP-05:10 | 10771.04 | 01-SEP-08:09 | 0.00 | 11135.36 | 17-SEP-08:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 28493.07 | 03-OCT-16:00 | 4566.05 | 01-OCT-05:10 | 10771.04 | 02-OCT-08:09 | 0.00 | 10945.28 | 19-OCT-06:10 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 28493.07 | 01-NOV-08:09 | 4566.05 | 01-NOV-05:10 | 10771.04 | 01-NOV-08:09 | 0.00 | 9787.50 | 05-NOV-08:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 28493.07 | 01-DEC-09:09 | 4566.05 | 01-DEC-06:10 | 10771.04 | 01-DEC-09:09 | 0.00 | 10319.72 | 04-DEC-07:30 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 26644.13 | 4566.05 | 10771.04 | 0.00 | 9255.75 | 0.00 | 0.00 | |||||
Maximum of Months | 28493.07 | 4566.05 | 10771.04 | 0.00 | 11923.34 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY {Maximum}[W] | HEATRECOVERY:ELECTRICITY {TIMESTAMP} | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 5725.08 | 20-JAN-13:09 | 0.00 | 0.00 | 1406.23 | 02-JAN-07:49 | 0.00 | 0.00 |
February | 15922.02 | 28-FEB-15:09 | 0.00 | 0.00 | 1406.23 | 01-FEB-07:49 | 0.00 | 0.00 |
March | 24839.23 | 30-MAR-14:09 | 0.00 | 0.00 | 1406.23 | 01-MAR-07:19 | 0.00 | 0.00 |
April | 24975.37 | 17-APR-14:39 | 0.00 | 0.00 | 1406.23 | 02-APR-09:30 | 0.00 | 0.00 |
May | 30469.09 | 30-MAY-14:00 | 0.00 | 0.00 | 1406.23 | 01-MAY-07:30 | 0.00 | 0.00 |
June | 36403.91 | 06-JUN-14:00 | 0.00 | 0.00 | 1406.23 | 04-JUN-17:10 | 0.00 | 0.00 |
July | 43221.37 | 08-JUL-14:30 | 0.00 | 0.00 | 1406.23 | 01-JUL-07:10 | 0.00 | 0.00 |
August | 40049.60 | 19-AUG-13:00 | 0.00 | 0.00 | 1406.23 | 01-AUG-11:09 | 0.00 | 0.00 |
September | 36188.41 | 07-SEP-14:00 | 0.00 | 0.00 | 1406.23 | 01-SEP-07:19 | 0.00 | 0.00 |
October | 30022.49 | 10-OCT-14:09 | 0.00 | 0.00 | 1406.23 | 02-OCT-07:10 | 0.00 | 0.00 |
November | 18743.54 | 02-NOV-14:09 | 0.00 | 0.00 | 1406.23 | 04-NOV-07:30 | 0.00 | 0.00 |
December | 14708.21 | 12-DEC-13:00 | 0.00 | 0.00 | 1406.23 | 01-DEC-07:19 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 5725.08 | 0.00 | 0.00 | 1406.23 | 0.00 | 0.00 | ||
Maximum of Months | 43221.37 | 0.00 | 0.00 | 1406.23 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 58880.75 | 19-JAN-17:00 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 8834.96 | 0.00 | 0.00 | 4809.42 | 0.00 |
February | 59093.10 | 28-FEB-17:10 | 28493.07 | 10771.04 | 0.00 | 0.00 | 6892.51 | 0.00 | 0.00 | 12936.49 | 0.00 |
March | 67879.32 | 30-MAR-16:40 | 26644.13 | 10771.04 | 0.00 | 0.00 | 6892.51 | 0.00 | 0.00 | 22165.42 | 0.00 |
April | 68544.19 | 17-APR-16:19 | 26644.13 | 10771.04 | 0.00 | 0.00 | 6892.51 | 0.00 | 0.00 | 22830.28 | 0.00 |
May | 73598.57 | 19-MAY-16:49 | 26644.13 | 10771.04 | 0.00 | 0.00 | 6892.51 | 0.00 | 0.00 | 27884.67 | 0.00 |
June | 76994.28 | 12-JUN-15:50 | 22946.26 | 10771.04 | 0.00 | 0.00 | 7175.93 | 0.00 | 0.00 | 34694.83 | 0.00 |
July | 84146.97 | 07-JUL-15:50 | 22946.26 | 10771.04 | 0.00 | 0.00 | 7889.06 | 0.00 | 0.00 | 41134.39 | 0.00 |
August | 82934.17 | 18-AUG-16:49 | 26644.13 | 10771.04 | 0.00 | 0.00 | 7452.50 | 0.00 | 0.00 | 36660.28 | 0.00 |
September | 79982.82 | 07-SEP-16:30 | 26644.13 | 10771.04 | 0.00 | 0.00 | 7354.26 | 0.00 | 0.00 | 33807.17 | 0.00 |
October | 75175.00 | 10-OCT-15:50 | 26644.13 | 10771.04 | 0.00 | 0.00 | 7178.78 | 0.00 | 0.00 | 29174.82 | 0.00 |
November | 64635.84 | 27-NOV-17:30 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 6892.51 | 0.00 | 0.00 | 12506.95 | 0.00 |
December | 59308.81 | 12-DEC-15:00 | 28493.07 | 10771.04 | 0.00 | 0.00 | 6892.51 | 0.00 | 0.00 | 13152.20 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 58880.75 | 22946.26 | 10771.04 | 0.00 | 0.00 | 6892.51 | 0.00 | 0.00 | 4809.42 | 0.00 | |
Maximum of Months | 84146.97 | 28493.07 | 10771.04 | 4566.05 | 0.00 | 8834.96 | 0.00 | 0.00 | 41134.39 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS {Maximum}[W] | WATERSYSTEMS:GAS {TIMESTAMP} | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 131051.03 | 09-JAN-07:10 | 0.00 | 5045.34 | 27-JAN-12:30 | 0.00 |
February | 0.00 | 0.00 | 132814.23 | 12-FEB-09:09 | 0.00 | 5045.63 | 03-FEB-12:00 | 0.00 |
March | 0.00 | 0.00 | 24593.20 | 23-MAR-06:10 | 0.00 | 5030.26 | 01-MAR-12:30 | 0.00 |
April | 0.00 | 0.00 | 15734.04 | 06-APR-06:10 | 0.00 | 4988.46 | 03-APR-11:50 | 0.00 |
May | 0.00 | 0.00 | 2118.36 | 10-MAY-11:09 | 0.00 | 4941.13 | 01-MAY-11:00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 4889.68 | 01-JUN-11:20 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 4851.45 | 03-JUL-11:20 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 4849.74 | 31-AUG-11:20 | 0.00 |
September | 0.00 | 0.00 | 2210.87 | 28-SEP-16:00 | 0.00 | 4881.84 | 29-SEP-11:20 | 0.00 |
October | 0.00 | 0.00 | 13564.12 | 25-OCT-11:09 | 0.00 | 4933.94 | 31-OCT-11:20 | 0.00 |
November | 0.00 | 0.00 | 37548.07 | 22-NOV-07:10 | 0.00 | 4986.94 | 30-NOV-12:39 | 0.00 |
December | 0.00 | 0.00 | 82368.96 | 04-DEC-07:10 | 0.00 | 5026.49 | 29-DEC-12:30 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 4849.74 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 132814.23 | 0.00 | 5045.63 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.33 | 17.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 17.07 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 17.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 17.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.17 | 16.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.50 | 17.12 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 17.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.50 | 17.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.50 | 16.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1.00 | 16.96 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.50 | 17.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.17 | 20.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.33 | 20.49 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 414.00 | 21.31 | 304.17 | 21.16 | 304.17 | 21.16 |
February | 376.00 | 21.97 | 165.83 | 21.30 | 165.83 | 21.30 |
March | 361.17 | 22.90 | 34.33 | 22.57 | 16.33 | 21.12 |
April | 233.67 | 23.41 | 55.33 | 23.82 | 19.50 | 23.70 |
May | 101.33 | 23.76 | 280.50 | 23.88 | 60.83 | 23.86 |
June | 18.50 | 23.91 | 348.00 | 23.89 | 10.00 | 23.95 |
July | 44.00 | 23.91 | 415.00 | 23.89 | 44.00 | 23.91 |
August | 25.33 | 23.95 | 422.00 | 23.89 | 25.33 | 23.95 |
September | 15.83 | 23.88 | 348.67 | 23.89 | 12.17 | 23.92 |
October | 229.17 | 23.45 | 111.83 | 23.88 | 35.00 | 23.88 |
November | 357.50 | 22.87 | 46.83 | 22.90 | 29.83 | 22.34 |
December | 414.17 | 21.78 | 133.33 | 21.33 | 133.33 | 21.33 |
Annual Sum or Average | 2590.67 | 22.50 | 2665.83 | 23.25 | 856.33 | 21.91 |
Minimum of Months | 15.83 | 21.31 | 34.33 | 21.16 | 10.00 | 21.12 |
Maximum of Months | 414.17 | 23.95 | 422.00 | 23.89 | 304.17 | 23.95 |
Report: ComfortReportSimple55Monthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 407.33 | 22.38 | 71.50 | 21.45 | 71.50 | 21.45 |
February | 326.67 | 22.96 | 37.17 | 21.91 | 28.33 | 21.29 |
March | 202.67 | 23.71 | 67.00 | 23.89 | 0.00 | 0.00 |
April | 60.67 | 23.75 | 167.67 | 23.89 | 2.67 | 23.89 |
May | 10.67 | 23.88 | 338.33 | 23.89 | 2.67 | 23.89 |
June | 0.00 | 0.00 | 377.17 | 23.89 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 415.00 | 23.89 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 421.17 | 23.89 | 0.00 | 0.00 |
September | 0.17 | 24.10 | 378.67 | 23.89 | 0.17 | 24.10 |
October | 57.00 | 23.77 | 157.67 | 23.89 | 8.33 | 23.89 |
November | 240.67 | 23.67 | 61.83 | 23.89 | 6.50 | 23.89 |
December | 364.50 | 23.23 | 23.00 | 23.37 | 11.00 | 22.80 |
Annual Sum or Average | 1670.33 | 23.13 | 2516.17 | 23.79 | 131.17 | 21.91 |
Minimum of Months | 0.00 | 0.00 | 23.00 | 21.45 | 0.00 | 0.00 |
Maximum of Months | 407.33 | 24.10 | 421.17 | 23.89 | 71.50 | 24.10 |
Report: ComfortReportSimple55Monthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 392.67 | 21.90 | 115.50 | 21.17 | 115.50 | 21.17 |
February | 282.33 | 22.07 | 71.83 | 21.46 | 62.67 | 21.11 |
March | 206.00 | 23.00 | 87.17 | 23.80 | 2.83 | 21.11 |
April | 120.00 | 23.28 | 177.67 | 23.89 | 5.50 | 23.86 |
May | 34.33 | 23.59 | 328.00 | 23.89 | 14.17 | 23.89 |
June | 11.67 | 23.87 | 372.00 | 23.89 | 6.83 | 23.92 |
July | 18.50 | 23.90 | 415.00 | 23.89 | 18.50 | 23.90 |
August | 7.67 | 23.95 | 422.00 | 23.89 | 7.67 | 23.95 |
September | 6.67 | 23.82 | 391.83 | 23.89 | 5.00 | 23.91 |
October | 87.33 | 23.19 | 237.67 | 23.89 | 21.67 | 23.89 |
November | 172.00 | 23.05 | 95.50 | 23.80 | 4.00 | 21.91 |
December | 343.00 | 22.59 | 55.33 | 22.80 | 24.83 | 21.46 |
Annual Sum or Average | 1682.17 | 22.58 | 2769.50 | 23.69 | 289.17 | 21.94 |
Minimum of Months | 6.67 | 21.90 | 55.33 | 21.17 | 2.83 | 21.11 |
Maximum of Months | 392.67 | 23.95 | 422.00 | 23.89 | 115.50 | 23.95 |
Report: ComfortReportSimple55Monthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 410.33 | 21.46 | 167.83 | 21.18 | 167.83 | 21.18 |
February | 329.67 | 21.77 | 101.50 | 21.18 | 101.50 | 21.18 |
March | 284.17 | 22.58 | 71.67 | 23.49 | 10.33 | 21.11 |
April | 184.00 | 22.89 | 136.50 | 23.79 | 15.50 | 23.02 |
May | 98.50 | 23.46 | 295.83 | 23.88 | 54.83 | 23.83 |
June | 33.67 | 23.77 | 354.17 | 23.89 | 23.83 | 23.89 |
July | 51.50 | 23.89 | 415.00 | 23.89 | 51.50 | 23.89 |
August | 29.67 | 23.93 | 422.00 | 23.89 | 29.67 | 23.93 |
September | 24.83 | 23.65 | 376.33 | 23.89 | 16.17 | 23.90 |
October | 150.33 | 22.74 | 200.33 | 23.87 | 31.00 | 23.79 |
November | 239.50 | 22.51 | 76.00 | 23.69 | 13.33 | 22.74 |
December | 375.33 | 21.90 | 71.17 | 22.09 | 53.00 | 21.47 |
Annual Sum or Average | 2211.50 | 22.28 | 2688.33 | 23.55 | 568.50 | 22.27 |
Minimum of Months | 24.83 | 21.46 | 71.17 | 21.18 | 10.33 | 21.11 |
Maximum of Months | 410.33 | 23.93 | 422.00 | 23.89 | 167.83 | 23.93 |
Report: ComfortReportSimple55Monthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.29466 | 30.56459 | -0.5562 | 12.56991 |
February | 376.00000 | 21.95868 | 32.30994 | -0.3529 | 10.02054 |
March | 422.00000 | 23.02715 | 37.78962 | 0.00547 | 6.72228 |
April | 405.00000 | 23.60578 | 43.89661 | 0.22693 | 6.98469 |
May | 418.00000 | 23.86425 | 51.58174 | -0.5060 | 10.69046 |
June | 408.00000 | 23.90993 | 51.32111 | -0.3932 | 8.39386 |
July | 415.00000 | 23.91378 | 56.04350 | -0.3299 | 7.32364 |
August | 422.00000 | 23.91426 | 55.78613 | -0.3218 | 7.22055 |
September | 405.00000 | 23.90606 | 53.78399 | -0.4197 | 8.79384 |
October | 414.00000 | 23.64520 | 47.00833 | 0.28315 | 7.35459 |
November | 399.00000 | 22.96587 | 37.46184 | -0.0011 | 6.80601 |
December | 415.00000 | 21.77434 | 34.78473 | -0.3513 | 9.26334 |
Annual Sum or Average | 4913.00000 | 23.15644 | 44.46458 | -0.2264 | 8.50461 |
Minimum of Months | 376.00000 | 21.29466 | 30.56459 | -0.5562 | 6.72228 |
Maximum of Months | 422.00000 | 23.91426 | 56.04350 | 0.28315 | 12.56991 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 22.39198 | 33.14623 | -0.2005 | 7.58416 |
February | 376.00000 | 23.07087 | 32.91214 | 0.00526 | 6.86709 |
March | 422.00000 | 23.80244 | 34.50408 | 0.27290 | 6.96851 |
April | 405.00000 | 23.87615 | 40.25220 | 0.37724 | 8.20513 |
May | 418.00000 | 23.90655 | 45.16982 | -0.4131 | 8.70779 |
June | 408.00000 | 23.91062 | 45.72081 | -0.3471 | 7.63352 |
July | 415.00000 | 23.91190 | 49.19205 | -0.3095 | 7.07418 |
August | 422.00000 | 23.91207 | 49.69882 | -0.3032 | 6.98257 |
September | 405.00000 | 23.90967 | 48.71321 | -0.3777 | 8.06499 |
October | 414.00000 | 23.88281 | 43.03751 | 0.39366 | 8.40910 |
November | 399.00000 | 23.75741 | 35.66827 | 0.25209 | 6.84529 |
December | 415.00000 | 23.29752 | 35.55766 | 0.07620 | 6.35085 |
Annual Sum or Average | 4913.00000 | 23.63948 | 41.20038 | -0.0492 | 7.47751 |
Minimum of Months | 376.00000 | 22.39198 | 32.91214 | -0.4131 | 6.35085 |
Maximum of Months | 422.00000 | 23.91207 | 49.69882 | 0.39366 | 8.70779 |
Report: OccupantComfortDataSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.98902 | 26.04962 | -0.2947 | 9.13401 |
February | 376.00000 | 22.51292 | 27.94269 | -0.1170 | 8.36536 |
March | 422.00000 | 23.44741 | 32.76387 | 0.20451 | 7.37206 |
April | 405.00000 | 23.70814 | 40.04717 | 0.33304 | 8.14794 |
May | 418.00000 | 23.87569 | 47.39500 | -0.4097 | 8.87811 |
June | 408.00000 | 23.90889 | 48.35402 | -0.3026 | 7.13069 |
July | 415.00000 | 23.91257 | 52.66781 | -0.2394 | 6.28818 |
August | 422.00000 | 23.91267 | 52.03545 | -0.2089 | 6.00391 |
September | 405.00000 | 23.90829 | 49.32180 | -0.2985 | 7.05405 |
October | 414.00000 | 23.74945 | 42.45785 | 0.41500 | 9.26178 |
November | 399.00000 | 23.52304 | 32.37476 | 0.24445 | 7.43320 |
December | 415.00000 | 22.80799 | 29.19198 | -0.0148 | 7.20537 |
Annual Sum or Average | 4913.00000 | 23.44408 | 40.15412 | -0.0579 | 7.68344 |
Minimum of Months | 376.00000 | 21.98902 | 26.04962 | -0.4097 | 6.00391 |
Maximum of Months | 422.00000 | 23.91267 | 52.66781 | 0.41500 | 9.26178 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 414.00000 | 21.46258 | 27.06313 | -0.4360 | 10.50649 |
February | 376.00000 | 22.01782 | 29.28776 | -0.2516 | 9.06718 |
March | 422.00000 | 22.99759 | 34.87365 | 0.08162 | 7.18347 |
April | 405.00000 | 23.42609 | 42.39882 | 0.24669 | 7.60753 |
May | 418.00000 | 23.78784 | 50.27942 | -0.4756 | 10.44815 |
June | 408.00000 | 23.89504 | 50.66019 | -0.3444 | 7.76059 |
July | 415.00000 | 23.91032 | 55.81011 | -0.2700 | 6.60034 |
August | 422.00000 | 23.91326 | 54.66747 | -0.2430 | 6.31739 |
September | 405.00000 | 23.88613 | 51.99505 | -0.3413 | 7.69742 |
October | 414.00000 | 23.47266 | 44.65461 | 0.33163 | 8.54300 |
November | 399.00000 | 23.05211 | 34.61534 | 0.12128 | 7.23282 |
December | 415.00000 | 22.08317 | 31.10295 | -0.1916 | 7.96027 |
Annual Sum or Average | 4913.00000 | 23.16656 | 42.39483 | -0.1479 | 8.07120 |
Minimum of Months | 376.00000 | 21.46258 | 27.06313 | -0.4756 | 6.31739 |
Maximum of Months | 422.00000 | 23.91326 | 55.81011 | 0.33163 | 10.50649 |
Report: OccupantComfortDataSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 0.00000 | ||||
Minimum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 0.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 1767.99 | 501.24 | 1.33 | 1235.02 | 532.98 | 0.00 | 0.00 | 20-JAN-15:40 | 0.00 | 01-JAN-00:10 | 0.55 | 20-JAN-15:40 | 0.38 | 20-JAN-15:40 | 0.17 | 20-JAN-15:40 | 0.16 | 20-JAN-15:40 | 0.00 | 01-JAN-00:10 |
February | 0.173896E+09 | 48258614.61 | 28.69 | 0.173896E+09 | 147.73 | 0.00 | 0.40 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 5931.04 | 28-FEB-15:10 | 5931.04 | 28-FEB-15:10 | 0.07 | 18-FEB-18:00 | 1612.65 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.131707E+10 | 0.349796E+09 | 134.72 | 0.102947E+10 | 0.287595E+09 | 0.00 | 0.71 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 | 24007.43 | 31-MAR-06:02 | 13708.07 | 31-MAR-06:02 | 10299.36 | 31-MAR-06:02 | 5108.21 | 31-MAR-06:02 | 0.00 | 01-MAR-00:10 |
April | 0.460328E+10 | 0.121516E+10 | 248.74 | 0.378786E+10 | 0.815419E+09 | 0.00 | 0.80 | 18-APR-06:02 | 0.00 | 01-APR-00:10 | 24982.02 | 19-APR-06:02 | 15566.04 | 19-APR-06:02 | 9415.98 | 19-APR-06:02 | 5323.21 | 19-APR-06:02 | 0.00 | 01-APR-00:10 |
May | 0.113667E+11 | 0.288212E+10 | 352.79 | 0.847418E+10 | 0.289250E+10 | 0.00 | 1.00 | 06-MAY-06:02 | 0.00 | 01-MAY-00:10 | 39397.92 | 26-MAY-06:02 | 28620.96 | 07-MAY-08:62 | 21018.29 | 26-MAY-06:02 | 8267.28 | 26-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.207902E+11 | 0.514409E+10 | 409.97 | 0.153219E+11 | 0.546836E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 40322.63 | 23-JUN-06:02 | 35276.87 | 11-JUN-08:62 | 21861.61 | 27-JUN-06:04 | 8534.68 | 25-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.250082E+11 | 0.612364E+10 | 428.49 | 0.174432E+11 | 0.756497E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 40873.55 | 30-JUL-08:62 | 29459.06 | 17-JUL-05:02 | 22844.15 | 31-JUL-06:04 | 8723.81 | 16-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.272256E+11 | 0.657309E+10 | 442.06 | 0.187010E+11 | 0.852461E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 41516.82 | 20-AUG-07:03 | 29421.32 | 26-AUG-06:04 | 22279.44 | 23-AUG-06:04 | 8667.76 | 20-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.161275E+11 | 0.392878E+10 | 385.89 | 0.113633E+11 | 0.476416E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 41225.93 | 17-SEP-08:62 | 29565.97 | 24-SEP-08:62 | 19928.87 | 17-SEP-08:04 | 8597.09 | 17-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.494318E+10 | 0.123356E+10 | 231.50 | 0.351399E+10 | 0.142918E+10 | 0.00 | 1.00 | 02-OCT-06:02 | 0.00 | 01-OCT-00:10 | 40428.05 | 19-OCT-06:02 | 21235.92 | 11-OCT-06:02 | 23781.08 | 19-OCT-06:04 | 8373.18 | 19-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.654478E+09 | 0.172967E+09 | 103.70 | 0.462045E+09 | 0.192433E+09 | 0.00 | 0.50 | 05-NOV-15:00 | 0.00 | 01-NOV-00:10 | 21262.36 | 04-NOV-06:02 | 11607.54 | 04-NOV-06:02 | 9654.81 | 04-NOV-06:02 | 4528.20 | 04-NOV-06:02 | 0.00 | 01-NOV-00:10 |
December | 52225520.65 | 14297438.71 | 13.56 | 36617211.18 | 15608309.47 | 0.00 | 0.25 | 12-DEC-15:10 | 0.00 | 01-DEC-00:10 | 3781.69 | 12-DEC-15:10 | 2853.79 | 12-DEC-15:10 | 1051.93 | 12-DEC-14:00 | 1027.26 | 12-DEC-15:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.112262E+12 | 0.276858E+11 | 2781.45 | 0.803075E+11 | 0.319548E+11 | 0.00 | ||||||||||||||
Minimum of Months | 1767.99 | 501.24 | 1.33 | 1235.02 | 147.73 | 0.00 | 0.00 | 0.00 | 0.55 | 0.38 | 0.07 | 0.16 | 0.00 | |||||||
Maximum of Months | 0.272256E+11 | 0.657309E+10 | 442.06 | 0.187010E+11 | 0.852461E+10 | 0.00 | 1.00 | 0.00 | 41516.82 | 35276.87 | 23781.08 | 8723.81 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.151521E+10 | 0.463397E+09 | 68.39 | 0.120758E+10 | 0.307626E+09 | 0.00 | 0.26 | 20-JAN-13:10 | 0.00 | 01-JAN-00:10 | 19364.52 | 20-JAN-13:10 | 12423.40 | 20-JAN-13:10 | 7127.92 | 19-JAN-17:30 | 5724.66 | 20-JAN-13:10 | 0.00 | 01-JAN-00:10 |
February | 0.497973E+10 | 0.150036E+10 | 148.54 | 0.443759E+10 | 0.542144E+09 | 0.00 | 0.50 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 37199.73 | 28-FEB-15:10 | 36344.11 | 28-FEB-15:10 | 8521.02 | 18-FEB-11:55 | 10985.41 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.174848E+11 | 0.511727E+10 | 326.66 | 0.140438E+11 | 0.344102E+10 | 0.00 | 1.00 | 29-MAR-06:03 | 0.00 | 01-MAR-00:10 | 185330.41 | 30-MAR-06:02 | 109787.69 | 29-MAR-06:03 | 75584.21 | 30-MAR-06:02 | 43995.75 | 30-MAR-06:02 | 0.00 | 01-MAR-00:10 |
April | 0.353747E+11 | 0.102174E+11 | 349.76 | 0.283296E+11 | 0.704512E+10 | 0.00 | 1.00 | 13-APR-06:03 | 0.00 | 01-APR-00:10 | 187573.51 | 23-APR-08:62 | 139798.90 | 16-APR-08:62 | 87233.18 | 23-APR-08:62 | 44423.79 | 23-APR-08:62 | 0.00 | 01-APR-00:10 |
May | 0.637674E+11 | 0.181035E+11 | 398.63 | 0.479633E+11 | 0.158041E+11 | 0.00 | 1.00 | 02-MAY-06:03 | 0.00 | 01-MAY-00:10 | 190509.70 | 31-MAY-06:02 | 148486.11 | 24-MAY-06:02 | 90386.32 | 27-MAY-06:02 | 44927.04 | 31-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.860205E+11 | 0.247795E+11 | 418.84 | 0.638871E+11 | 0.221334E+11 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 192258.45 | 19-JUN-06:02 | 165419.36 | 11-JUN-08:62 | 62202.75 | 02-JUN-06:02 | 46087.62 | 25-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.983115E+11 | 0.281444E+11 | 432.74 | 0.692816E+11 | 0.290299E+11 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 195265.74 | 30-JUL-08:62 | 149769.70 | 08-JUL-05:02 | 90240.16 | 29-JUL-06:02 | 47372.53 | 16-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.103309E+12 | 0.293068E+11 | 440.73 | 0.716597E+11 | 0.316491E+11 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 193688.21 | 12-AUG-06:02 | 154598.99 | 26-AUG-06:02 | 85036.43 | 25-AUG-06:02 | 47037.80 | 20-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.706488E+11 | 0.198735E+11 | 402.59 | 0.501849E+11 | 0.204639E+11 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 195772.05 | 17-SEP-08:62 | 149835.04 | 24-SEP-08:62 | 83533.67 | 30-SEP-06:02 | 46771.16 | 17-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.334245E+11 | 0.949745E+10 | 346.69 | 0.247610E+11 | 0.866352E+10 | 0.00 | 1.00 | 01-OCT-08:62 | 0.00 | 01-OCT-00:10 | 195033.12 | 19-OCT-06:02 | 133754.43 | 12-OCT-06:02 | 95690.60 | 02-OCT-06:02 | 45568.23 | 19-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.130865E+11 | 0.385709E+10 | 284.13 | 0.104266E+11 | 0.265984E+10 | 0.00 | 1.00 | 04-NOV-06:02 | 0.00 | 01-NOV-00:10 | 184277.06 | 04-NOV-06:02 | 103070.70 | 04-NOV-06:02 | 81206.36 | 04-NOV-06:02 | 43782.20 | 04-NOV-06:02 | 0.00 | 01-NOV-00:10 |
December | 0.649158E+10 | 0.195854E+10 | 200.03 | 0.530457E+10 | 0.118701E+10 | 0.00 | 0.72 | 13-DEC-07:03 | 0.00 | 01-DEC-00:10 | 152958.41 | 13-DEC-07:03 | 86651.00 | 13-DEC-07:03 | 66307.41 | 13-DEC-07:03 | 36355.46 | 13-DEC-07:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.534414E+12 | 0.152819E+12 | 3817.73 | 0.391487E+12 | 0.142927E+12 | 0.00 | ||||||||||||||
Minimum of Months | 0.151521E+10 | 0.463397E+09 | 68.39 | 0.120758E+10 | 0.307626E+09 | 0.00 | 0.26 | 0.00 | 19364.52 | 12423.40 | 7127.92 | 5724.66 | 0.00 | |||||||
Maximum of Months | 0.103309E+12 | 0.293068E+11 | 440.73 | 0.716597E+11 | 0.316491E+11 | 0.00 | 1.00 | 0.00 | 195772.05 | 165419.36 | 95690.60 | 47372.53 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 51522900.08 | 13674385.47 | 33.28 | 42538816.24 | 8984083.84 | 0.00 | 0.34 | 31-JAN-14:50 | 0.00 | 01-JAN-00:10 | 3160.90 | 31-JAN-14:50 | 2818.90 | 31-JAN-15:00 | 530.99 | 31-JAN-13:00 | 819.99 | 31-JAN-14:50 | 0.00 | 01-JAN-00:10 |
February | 0.816931E+09 | 0.206095E+09 | 92.60 | 0.811357E+09 | 5574008.78 | 0.00 | 0.77 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 7963.59 | 28-FEB-15:10 | 7963.59 | 28-FEB-15:10 | 383.82 | 22-FEB-15:20 | 1944.02 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.245334E+10 | 0.611356E+09 | 235.05 | 0.201130E+10 | 0.442039E+09 | 0.00 | 1.00 | 30-MAR-06:02 | 0.00 | 01-MAR-00:10 | 23972.72 | 30-MAR-06:02 | 13978.83 | 30-MAR-06:02 | 9993.88 | 30-MAR-06:02 | 5091.75 | 30-MAR-06:02 | 0.00 | 01-MAR-00:10 |
April | 0.504264E+10 | 0.126496E+10 | 296.01 | 0.420386E+10 | 0.838778E+09 | 0.00 | 1.00 | 18-APR-06:02 | 0.00 | 01-APR-00:10 | 23177.55 | 19-APR-06:02 | 14911.21 | 18-APR-06:02 | 8504.32 | 19-APR-06:02 | 4935.74 | 19-APR-06:02 | 0.00 | 01-APR-00:10 |
May | 0.934655E+10 | 0.229716E+10 | 373.08 | 0.711403E+10 | 0.223252E+10 | 0.00 | 1.00 | 03-MAY-06:02 | 0.00 | 01-MAY-00:10 | 25000.88 | 31-MAY-06:02 | 17917.30 | 07-MAY-08:62 | 12773.70 | 31-MAY-06:02 | 5246.30 | 31-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.146402E+11 | 0.358242E+10 | 410.53 | 0.108625E+11 | 0.377773E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 25746.67 | 26-JUN-05:03 | 22227.77 | 11-JUN-08:62 | 13995.71 | 20-JUN-06:02 | 5424.05 | 26-JUN-05:03 | 0.00 | 01-JUN-00:10 |
July | 0.175198E+11 | 0.425994E+10 | 431.58 | 0.122808E+11 | 0.523895E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 26032.46 | 30-JUL-08:62 | 18604.65 | 15-JUL-05:03 | 14692.87 | 31-JUL-06:02 | 5530.22 | 16-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.196384E+11 | 0.471156E+10 | 443.26 | 0.136538E+11 | 0.598459E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 26504.71 | 20-AUG-07:03 | 19409.05 | 26-AUG-06:02 | 14048.10 | 23-AUG-06:02 | 5495.02 | 20-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.131085E+11 | 0.310251E+10 | 395.05 | 0.948708E+10 | 0.362138E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 26014.26 | 17-SEP-08:62 | 19677.39 | 09-SEP-05:03 | 14364.90 | 03-SEP-08:62 | 5450.95 | 17-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.622673E+10 | 0.147136E+10 | 292.41 | 0.481851E+10 | 0.140822E+10 | 0.00 | 1.00 | 02-OCT-06:02 | 0.00 | 01-OCT-00:10 | 25663.13 | 19-OCT-06:02 | 15544.16 | 09-OCT-08:62 | 15151.17 | 19-OCT-06:02 | 5314.26 | 19-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.237931E+10 | 0.584529E+09 | 204.81 | 0.196289E+10 | 0.416411E+09 | 0.00 | 1.00 | 04-NOV-06:02 | 0.00 | 01-NOV-00:10 | 23685.42 | 04-NOV-06:02 | 13429.39 | 04-NOV-06:02 | 10256.03 | 04-NOV-06:02 | 5038.82 | 04-NOV-06:02 | 0.00 | 01-NOV-00:10 |
December | 0.517292E+09 | 0.127031E+09 | 97.52 | 0.371841E+09 | 0.145451E+09 | 0.00 | 0.85 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 20734.08 | 13-DEC-07:03 | 11877.69 | 13-DEC-07:03 | 8856.39 | 13-DEC-07:03 | 4410.45 | 13-DEC-07:03 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.917412E+11 | 0.222326E+11 | 3305.17 | 0.676205E+11 | 0.241206E+11 | 0.00 | ||||||||||||||
Minimum of Months | 51522900.08 | 13674385.47 | 33.28 | 42538816.24 | 5574008.78 | 0.00 | 0.34 | 0.00 | 3160.90 | 2818.90 | 383.82 | 819.99 | 0.00 | |||||||
Maximum of Months | 0.196384E+11 | 0.471156E+10 | 443.26 | 0.136538E+11 | 0.598459E+10 | 0.00 | 1.00 | 0.00 | 26504.71 | 22227.77 | 15151.17 | 5530.22 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 7835039.20 | 2164464.52 | 9.64 | 6532099.18 | 1302940.03 | 0.00 | 0.15 | 31-JAN-15:10 | 0.00 | 01-JAN-00:10 | 1044.94 | 31-JAN-15:10 | 898.94 | 31-JAN-15:10 | 149.19 | 31-JAN-14:30 | 285.74 | 31-JAN-15:10 | 0.00 | 01-JAN-00:10 |
February | 0.444273E+09 | 0.114413E+09 | 63.72 | 0.442489E+09 | 1784563.46 | 0.00 | 0.67 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 | 5483.94 | 28-FEB-15:10 | 5483.94 | 28-FEB-15:10 | 100.97 | 22-FEB-15:00 | 1379.94 | 28-FEB-15:10 | 0.00 | 01-FEB-00:10 |
March | 0.130283E+10 | 0.332542E+09 | 163.07 | 0.102962E+10 | 0.273210E+09 | 0.00 | 0.95 | 30-MAR-14:10 | 0.00 | 01-MAR-00:10 | 15380.69 | 31-MAR-06:02 | 8684.64 | 31-MAR-06:02 | 6696.05 | 31-MAR-06:02 | 3271.09 | 31-MAR-06:02 | 0.00 | 01-MAR-00:10 |
April | 0.299591E+10 | 0.773183E+09 | 240.12 | 0.243529E+10 | 0.560624E+09 | 0.00 | 0.98 | 19-APR-06:02 | 0.00 | 01-APR-00:10 | 9209.30 | 19-APR-06:02 | 6671.96 | 17-APR-14:30 | 3645.00 | 19-APR-06:02 | 1974.79 | 19-APR-06:02 | 0.00 | 01-APR-00:10 |
May | 0.618950E+10 | 0.155176E+10 | 343.92 | 0.450574E+10 | 0.168376E+10 | 0.00 | 1.00 | 07-MAY-08:62 | 0.00 | 01-MAY-00:10 | 20440.81 | 31-MAY-06:02 | 13666.26 | 07-MAY-08:62 | 10634.92 | 31-MAY-06:02 | 4289.51 | 31-MAY-06:02 | 0.00 | 01-MAY-00:10 |
June | 0.113148E+11 | 0.277192E+10 | 402.68 | 0.794424E+10 | 0.337055E+10 | 0.00 | 1.00 | 01-JUN-06:02 | 0.00 | 01-JUN-00:10 | 21019.69 | 23-JUN-06:02 | 15655.19 | 04-JUN-08:62 | 11546.01 | 27-JUN-06:02 | 4435.45 | 25-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.138910E+11 | 0.336827E+10 | 423.71 | 0.918375E+10 | 0.470723E+10 | 0.00 | 1.00 | 01-JUL-06:02 | 0.00 | 01-JUL-00:10 | 21367.04 | 30-JUL-08:62 | 13519.72 | 15-JUL-06:02 | 12019.58 | 31-JUL-06:02 | 4535.26 | 16-JUL-08:62 | 0.00 | 01-JUL-00:10 |
August | 0.159321E+11 | 0.380270E+10 | 441.86 | 0.104125E+11 | 0.551958E+10 | 0.00 | 1.00 | 01-AUG-06:02 | 0.00 | 01-AUG-00:10 | 21631.35 | 20-AUG-07:03 | 14129.01 | 10-AUG-05:02 | 11745.55 | 23-AUG-06:04 | 4498.68 | 20-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.986121E+10 | 0.234506E+10 | 378.38 | 0.673778E+10 | 0.312343E+10 | 0.00 | 1.00 | 01-SEP-06:02 | 0.00 | 01-SEP-00:10 | 21470.92 | 17-SEP-08:62 | 14539.42 | 24-SEP-08:62 | 11828.18 | 03-SEP-08:62 | 4462.89 | 17-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 0.431966E+10 | 0.103014E+10 | 246.33 | 0.318580E+10 | 0.113386E+10 | 0.00 | 1.00 | 09-OCT-08:62 | 0.00 | 01-OCT-00:10 | 21001.12 | 19-OCT-06:02 | 12377.24 | 09-OCT-08:62 | 12498.10 | 19-OCT-06:02 | 4346.67 | 19-OCT-06:02 | 0.00 | 01-OCT-00:10 |
November | 0.122405E+10 | 0.308445E+09 | 146.53 | 0.990156E+09 | 0.233896E+09 | 0.00 | 0.75 | 02-NOV-14:30 | 0.00 | 01-NOV-00:10 | 10036.66 | 04-NOV-06:02 | 5376.90 | 04-NOV-06:02 | 4659.76 | 04-NOV-06:02 | 2138.07 | 04-NOV-06:02 | 0.00 | 01-NOV-00:10 |
December | 0.226532E+09 | 56982219.64 | 42.18 | 0.155829E+09 | 70702694.95 | 0.00 | 0.75 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 | 6779.79 | 12-DEC-14:00 | 4939.19 | 12-DEC-14:00 | 2034.68 | 12-DEC-13:20 | 1596.13 | 12-DEC-14:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.677096E+11 | 0.164576E+11 | 2902.15 | 0.470297E+11 | 0.206799E+11 | 0.00 | ||||||||||||||
Minimum of Months | 7835039.20 | 2164464.52 | 9.64 | 6532099.18 | 1302940.03 | 0.00 | 0.15 | 0.00 | 1044.94 | 898.94 | 100.97 | 285.74 | 0.00 | |||||||
Maximum of Months | 0.159321E+11 | 0.380270E+10 | 441.86 | 0.104125E+11 | 0.551958E+10 | 0.00 | 1.00 | 0.00 | 21631.35 | 15655.19 | 12498.10 | 4535.26 | 0.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 64.45 | 35.62 | 28.83 | 57.35 | 81.27 | 1.00 | 0.00 | 744.00 |
February | 80.55 | 49.88 | 30.67 | 83.19 | 71.45 | 0.83 | 0.00 | 672.00 |
March | 116.88 | 71.36 | 45.52 | 136.08 | 51.35 | 0.00 | 0.00 | 744.00 |
April | 147.03 | 90.61 | 56.42 | 185.32 | 41.81 | 0.00 | 0.00 | 720.00 |
May | 162.85 | 93.43 | 69.42 | 214.06 | 29.23 | 0.00 | 0.00 | 744.00 |
June | 173.77 | 101.69 | 72.07 | 238.31 | 22.22 | 0.00 | 0.00 | 720.00 |
July | 161.80 | 90.85 | 70.95 | 225.84 | 17.31 | 0.00 | 0.00 | 744.00 |
August | 148.91 | 80.81 | 68.11 | 209.34 | 16.59 | 0.00 | 0.00 | 744.00 |
September | 111.46 | 61.91 | 49.54 | 146.84 | 27.90 | 0.00 | 0.00 | 720.00 |
October | 95.58 | 64.22 | 31.36 | 115.16 | 48.62 | 0.00 | 0.00 | 744.00 |
November | 71.19 | 40.30 | 30.89 | 76.00 | 63.35 | 1.50 | 0.00 | 720.00 |
December | 58.27 | 31.76 | 26.51 | 53.83 | 75.06 | 13.83 | 0.00 | 744.00 |
Annual Sum or Average | 116.25 | 67.79 | 48.46 | 145.44 | 45.37 | 17.17 | 0.00 | 8760.00 |
Minimum of Months | 58.27 | 31.76 | 26.51 | 53.83 | 16.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 173.77 | 101.69 | 72.07 | 238.31 | 81.27 | 13.83 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 866.15 | 603.94 | 262.21 | 968.59 | 960.67 | 0.00 | 0.00 | 744.00 |
February | 808.40 | 541.95 | 266.45 | 954.83 | 839.62 | 0.00 | 0.00 | 672.00 |
March | 726.74 | 378.67 | 348.06 | 861.57 | 601.20 | 0.00 | 0.00 | 744.00 |
April | 544.19 | 177.02 | 367.17 | 658.99 | 487.00 | 0.00 | 0.00 | 720.00 |
May | 439.66 | 50.95 | 388.71 | 575.87 | 326.65 | 0.00 | 0.00 | 744.00 |
June | 406.50 | 22.47 | 384.04 | 672.68 | 222.13 | 0.00 | 0.00 | 720.00 |
July | 410.98 | 30.50 | 380.48 | 715.95 | 165.82 | 0.00 | 0.00 | 744.00 |
August | 490.71 | 91.54 | 399.17 | 846.90 | 150.19 | 0.00 | 0.00 | 744.00 |
September | 539.68 | 200.64 | 339.04 | 797.60 | 296.17 | 0.00 | 0.00 | 720.00 |
October | 782.65 | 507.02 | 275.63 | 1067.80 | 580.09 | 0.00 | 0.00 | 744.00 |
November | 842.16 | 558.92 | 283.24 | 1074.67 | 734.68 | 0.00 | 0.00 | 720.00 |
December | 853.76 | 600.68 | 253.08 | 1014.68 | 863.49 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 641.92 | 312.63 | 329.30 | 850.54 | 517.26 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 406.50 | 22.47 | 253.08 | 575.87 | 150.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 866.15 | 603.94 | 399.17 | 1074.67 | 960.67 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 866.15 | 603.94 | 262.21 | 978.54 | 930.31 | 0.00 | 0.00 | 744.00 |
February | 808.40 | 541.95 | 266.45 | 961.98 | 807.11 | 0.00 | 0.00 | 672.00 |
March | 726.74 | 378.67 | 348.06 | 869.75 | 570.09 | 0.00 | 0.00 | 744.00 |
April | 544.19 | 177.02 | 367.17 | 663.25 | 461.58 | 0.00 | 0.00 | 720.00 |
May | 439.66 | 50.95 | 388.71 | 575.74 | 307.76 | 0.00 | 0.00 | 744.00 |
June | 406.50 | 22.47 | 384.04 | 669.56 | 207.39 | 0.00 | 0.00 | 720.00 |
July | 410.98 | 30.50 | 380.48 | 712.89 | 152.20 | 0.00 | 0.00 | 744.00 |
August | 490.71 | 91.54 | 399.17 | 843.12 | 136.40 | 0.00 | 0.00 | 744.00 |
September | 539.68 | 200.64 | 339.04 | 795.03 | 280.72 | 0.00 | 0.00 | 720.00 |
October | 782.65 | 507.02 | 275.63 | 1069.40 | 555.10 | 0.00 | 0.00 | 744.00 |
November | 842.16 | 558.92 | 283.24 | 1081.68 | 703.35 | 0.00 | 0.00 | 720.00 |
December | 853.76 | 600.68 | 253.08 | 1025.69 | 822.26 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 641.92 | 312.63 | 329.30 | 853.56 | 492.84 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 406.50 | 22.47 | 253.08 | 575.74 | 136.40 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 866.15 | 603.94 | 399.17 | 1081.68 | 930.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 178.22 | 124.27 | 53.95 | 196.31 | 190.34 | 0.00 | 0.00 | 744.00 |
February | 166.34 | 111.51 | 54.83 | 194.20 | 164.31 | 0.00 | 0.00 | 672.00 |
March | 149.54 | 77.92 | 71.62 | 178.26 | 113.02 | 0.00 | 0.00 | 744.00 |
April | 111.97 | 36.42 | 75.55 | 134.06 | 92.29 | 0.00 | 0.00 | 720.00 |
May | 90.47 | 10.48 | 79.98 | 112.23 | 62.69 | 0.00 | 0.00 | 744.00 |
June | 83.64 | 4.62 | 79.02 | 117.22 | 46.61 | 0.00 | 0.00 | 720.00 |
July | 84.56 | 6.28 | 78.29 | 122.32 | 36.24 | 0.00 | 0.00 | 744.00 |
August | 100.97 | 18.84 | 82.13 | 147.52 | 34.63 | 0.00 | 0.00 | 744.00 |
September | 111.05 | 41.28 | 69.76 | 152.32 | 60.28 | 0.00 | 0.00 | 720.00 |
October | 161.04 | 104.33 | 56.72 | 217.51 | 111.16 | 0.00 | 0.00 | 744.00 |
November | 173.29 | 115.01 | 58.28 | 221.88 | 138.88 | 0.00 | 0.00 | 720.00 |
December | 175.67 | 123.60 | 52.08 | 207.65 | 166.01 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 132.08 | 64.33 | 67.76 | 166.68 | 101.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 83.64 | 4.62 | 52.08 | 112.23 | 34.63 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 178.22 | 124.27 | 82.13 | 221.88 | 190.34 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R4C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R1C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R2C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHTS_R3C4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.172635E+09 | 95413690.10 | 77221269.73 | 0.153604E+09 | 0.217681E+09 |
February | 0.194858E+09 | 0.120666E+09 | 74192313.62 | 0.201249E+09 | 0.172849E+09 |
March | 0.313045E+09 | 0.191129E+09 | 0.121916E+09 | 0.364480E+09 | 0.137538E+09 |
April | 0.381089E+09 | 0.234852E+09 | 0.146237E+09 | 0.480343E+09 | 0.108359E+09 |
May | 0.436178E+09 | 0.250247E+09 | 0.185931E+09 | 0.573350E+09 | 78285388.23 |
June | 0.450402E+09 | 0.263593E+09 | 0.186809E+09 | 0.617693E+09 | 57583888.59 |
July | 0.433368E+09 | 0.243339E+09 | 0.190029E+09 | 0.604877E+09 | 46372847.50 |
August | 0.398843E+09 | 0.216428E+09 | 0.182415E+09 | 0.560709E+09 | 44437973.52 |
September | 0.288893E+09 | 0.160481E+09 | 0.128412E+09 | 0.380620E+09 | 72328587.12 |
October | 0.255999E+09 | 0.172001E+09 | 83998314.46 | 0.308445E+09 | 0.130224E+09 |
November | 0.184524E+09 | 0.104468E+09 | 80055914.30 | 0.196980E+09 | 0.164215E+09 |
December | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 0.201039E+09 |
Annual Sum or Average | 0.366591E+10 | 0.213768E+10 | 0.152823E+10 | 0.458652E+10 | 0.143091E+10 |
Minimum of Months | 0.156075E+09 | 85062197.81 | 71012508.49 | 0.144170E+09 | 44437973.52 |
Maximum of Months | 0.450402E+09 | 0.263593E+09 | 0.190029E+09 | 0.617693E+09 | 0.217681E+09 |
Report: WindowEnergyReportMonthly
For: POINT_OF_SALE_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.231990E+10 | 0.161759E+10 | 0.702308E+09 | 0.259426E+10 | 0.257307E+10 |
February | 0.195567E+10 | 0.131108E+10 | 0.644589E+09 | 0.230993E+10 | 0.203121E+10 |
March | 0.194650E+10 | 0.101424E+10 | 0.932255E+09 | 0.230762E+10 | 0.161025E+10 |
April | 0.141053E+10 | 0.458839E+09 | 0.951695E+09 | 0.170811E+10 | 0.126231E+10 |
May | 0.117758E+10 | 0.136466E+09 | 0.104112E+10 | 0.154240E+10 | 0.874911E+09 |
June | 0.105366E+10 | 58231071.12 | 0.995429E+09 | 0.174358E+10 | 0.575771E+09 |
July | 0.110077E+10 | 81695334.73 | 0.101907E+10 | 0.191760E+10 | 0.444121E+09 |
August | 0.131433E+10 | 0.245192E+09 | 0.106914E+10 | 0.226833E+10 | 0.402273E+09 |
September | 0.139885E+10 | 0.520056E+09 | 0.878796E+09 | 0.206738E+10 | 0.767663E+09 |
October | 0.209624E+10 | 0.135799E+10 | 0.738250E+09 | 0.285999E+10 | 0.155372E+10 |
November | 0.218287E+10 | 0.144871E+10 | 0.734162E+09 | 0.278556E+10 | 0.190428E+10 |
December | 0.228670E+10 | 0.160885E+10 | 0.677853E+09 | 0.271772E+10 | 0.231277E+10 |
Annual Sum or Average | 0.202436E+11 | 0.985895E+10 | 0.103847E+11 | 0.268225E+11 | 0.163123E+11 |
Minimum of Months | 0.105366E+10 | 58231071.12 | 0.644589E+09 | 0.154240E+10 | 0.402273E+09 |
Maximum of Months | 0.231990E+10 | 0.161759E+10 | 0.106914E+10 | 0.285999E+10 | 0.257307E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_RETAIL_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.231990E+10 | 0.161759E+10 | 0.702308E+09 | 0.262093E+10 | 0.249175E+10 |
February | 0.195567E+10 | 0.131108E+10 | 0.644589E+09 | 0.232722E+10 | 0.195257E+10 |
March | 0.194650E+10 | 0.101424E+10 | 0.932255E+09 | 0.232955E+10 | 0.152693E+10 |
April | 0.141053E+10 | 0.458839E+09 | 0.951695E+09 | 0.171915E+10 | 0.119641E+10 |
May | 0.117758E+10 | 0.136466E+09 | 0.104112E+10 | 0.154206E+10 | 0.824311E+09 |
June | 0.105366E+10 | 58231071.12 | 0.995429E+09 | 0.173550E+10 | 0.537558E+09 |
July | 0.110077E+10 | 81695334.73 | 0.101907E+10 | 0.190939E+10 | 0.407653E+09 |
August | 0.131433E+10 | 0.245192E+09 | 0.106914E+10 | 0.225821E+10 | 0.365342E+09 |
September | 0.139885E+10 | 0.520056E+09 | 0.878796E+09 | 0.206072E+10 | 0.727618E+09 |
October | 0.209624E+10 | 0.135799E+10 | 0.738250E+09 | 0.286427E+10 | 0.148677E+10 |
November | 0.218287E+10 | 0.144871E+10 | 0.734162E+09 | 0.280371E+10 | 0.182309E+10 |
December | 0.228670E+10 | 0.160885E+10 | 0.677853E+09 | 0.274720E+10 | 0.220233E+10 |
Annual Sum or Average | 0.202436E+11 | 0.985895E+10 | 0.103847E+11 | 0.269179E+11 | 0.155423E+11 |
Minimum of Months | 0.105366E+10 | 58231071.12 | 0.644589E+09 | 0.154206E+10 | 0.365342E+09 |
Maximum of Months | 0.231990E+10 | 0.161759E+10 | 0.106914E+10 | 0.286427E+10 | 0.249175E+10 |
Report: WindowEnergyReportMonthly
For: FRONT_ENTRY_WALL_SOUTH_GLAZING
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.477354E+09 | 0.332844E+09 | 0.144510E+09 | 0.525788E+09 | 0.509795E+09 |
February | 0.402408E+09 | 0.269774E+09 | 0.132634E+09 | 0.469805E+09 | 0.397496E+09 |
March | 0.400520E+09 | 0.208695E+09 | 0.191825E+09 | 0.477460E+09 | 0.302710E+09 |
April | 0.290238E+09 | 94412838.34 | 0.195825E+09 | 0.347483E+09 | 0.239222E+09 |
May | 0.242305E+09 | 28079908.65 | 0.214225E+09 | 0.300593E+09 | 0.167900E+09 |
June | 0.216806E+09 | 11981890.80 | 0.204824E+09 | 0.303828E+09 | 0.120808E+09 |
July | 0.226499E+09 | 16810004.70 | 0.209689E+09 | 0.327630E+09 | 97067116.40 |
August | 0.270442E+09 | 50451868.80 | 0.219990E+09 | 0.395112E+09 | 92757304.29 |
September | 0.287834E+09 | 0.107009E+09 | 0.180825E+09 | 0.394801E+09 | 0.156241E+09 |
October | 0.431332E+09 | 0.279427E+09 | 0.151906E+09 | 0.582590E+09 | 0.297736E+09 |
November | 0.449158E+09 | 0.298093E+09 | 0.151064E+09 | 0.575109E+09 | 0.359978E+09 |
December | 0.470522E+09 | 0.331044E+09 | 0.139478E+09 | 0.556178E+09 | 0.444647E+09 |
Annual Sum or Average | 0.416542E+10 | 0.202862E+10 | 0.213680E+10 | 0.525638E+10 | 0.318636E+10 |
Minimum of Months | 0.216806E+09 | 11981890.80 | 0.132634E+09 | 0.300593E+09 | 92757304.29 |
Maximum of Months | 0.477354E+09 | 0.332844E+09 | 0.219990E+09 | 0.582590E+09 | 0.509795E+09 |
Report: WindowZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 917.59 | 1300.37 | 1031.27 | 569.97 | 461.30 | 0.00 | 0.00 |
February | 1331.01 | 1143.18 | 1288.74 | 798.05 | 490.69 | 0.00 | 0.00 |
March | 2177.30 | 821.61 | 1870.04 | 1141.75 | 728.29 | 0.00 | 0.00 |
April | 2965.08 | 668.88 | 2352.40 | 1449.70 | 902.70 | 0.00 | 0.00 |
May | 3425.03 | 467.65 | 2605.60 | 1494.90 | 1110.70 | 0.00 | 0.00 |
June | 3812.92 | 355.46 | 2780.26 | 1627.12 | 1153.14 | 0.00 | 0.00 |
July | 3613.37 | 277.02 | 2588.82 | 1453.64 | 1135.18 | 0.00 | 0.00 |
August | 3349.52 | 265.46 | 2382.58 | 1292.88 | 1089.69 | 0.00 | 0.00 |
September | 2349.51 | 446.47 | 1783.29 | 990.62 | 792.67 | 0.00 | 0.00 |
October | 1842.56 | 777.92 | 1529.27 | 1027.48 | 501.78 | 0.00 | 0.00 |
November | 1215.93 | 1013.67 | 1139.03 | 644.86 | 494.17 | 0.00 | 0.00 |
December | 861.23 | 1200.95 | 932.35 | 508.14 | 424.21 | 0.00 | 0.00 |
Annual Sum or Average | 2327.00 | 725.98 | 1859.92 | 1084.56 | 775.36 | 0.00 | 0.00 |
Minimum of Months | 861.23 | 265.46 | 932.35 | 508.14 | 424.21 | 0.00 | 0.00 |
Maximum of Months | 3812.92 | 1300.37 | 2780.26 | 1627.12 | 1153.14 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 968.59 | 960.67 | 866.15 | 603.94 | 262.21 | 0.00 | 0.00 |
February | 954.83 | 839.62 | 808.40 | 541.95 | 266.45 | 0.00 | 0.00 |
March | 861.57 | 601.20 | 726.74 | 378.67 | 348.06 | 0.00 | 0.00 |
April | 658.99 | 487.00 | 544.19 | 177.02 | 367.17 | 0.00 | 0.00 |
May | 575.87 | 326.65 | 439.66 | 50.95 | 388.71 | 0.00 | 0.00 |
June | 672.68 | 222.13 | 406.50 | 22.47 | 384.04 | 0.00 | 0.00 |
July | 715.95 | 165.82 | 410.98 | 30.50 | 380.48 | 0.00 | 0.00 |
August | 846.90 | 150.19 | 490.71 | 91.54 | 399.17 | 0.00 | 0.00 |
September | 797.60 | 296.17 | 539.68 | 200.64 | 339.04 | 0.00 | 0.00 |
October | 1067.80 | 580.09 | 782.65 | 507.02 | 275.63 | 0.00 | 0.00 |
November | 1074.67 | 734.68 | 842.16 | 558.92 | 283.24 | 0.00 | 0.00 |
December | 1014.68 | 863.49 | 853.76 | 600.68 | 253.08 | 0.00 | 0.00 |
Annual Sum or Average | 850.54 | 517.26 | 641.92 | 312.63 | 329.30 | 0.00 | 0.00 |
Minimum of Months | 575.87 | 150.19 | 406.50 | 22.47 | 253.08 | 0.00 | 0.00 |
Maximum of Months | 1074.67 | 960.67 | 866.15 | 603.94 | 399.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 978.54 | 930.31 | 866.15 | 603.94 | 262.21 | 0.00 | 0.00 |
February | 961.98 | 807.11 | 808.40 | 541.95 | 266.45 | 0.00 | 0.00 |
March | 869.75 | 570.09 | 726.74 | 378.67 | 348.06 | 0.00 | 0.00 |
April | 663.25 | 461.58 | 544.19 | 177.02 | 367.17 | 0.00 | 0.00 |
May | 575.74 | 307.76 | 439.66 | 50.95 | 388.71 | 0.00 | 0.00 |
June | 669.56 | 207.39 | 406.50 | 22.47 | 384.04 | 0.00 | 0.00 |
July | 712.89 | 152.20 | 410.98 | 30.50 | 380.48 | 0.00 | 0.00 |
August | 843.12 | 136.40 | 490.71 | 91.54 | 399.17 | 0.00 | 0.00 |
September | 795.03 | 280.72 | 539.68 | 200.64 | 339.04 | 0.00 | 0.00 |
October | 1069.40 | 555.10 | 782.65 | 507.02 | 275.63 | 0.00 | 0.00 |
November | 1081.68 | 703.35 | 842.16 | 558.92 | 283.24 | 0.00 | 0.00 |
December | 1025.69 | 822.26 | 853.76 | 600.68 | 253.08 | 0.00 | 0.00 |
Annual Sum or Average | 853.56 | 492.84 | 641.92 | 312.63 | 329.30 | 0.00 | 0.00 |
Minimum of Months | 575.74 | 136.40 | 406.50 | 22.47 | 253.08 | 0.00 | 0.00 |
Maximum of Months | 1081.68 | 930.31 | 866.15 | 603.94 | 399.17 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 196.31 | 190.34 | 178.22 | 124.27 | 53.95 | 0.00 | 0.00 |
February | 194.20 | 164.31 | 166.34 | 111.51 | 54.83 | 0.00 | 0.00 |
March | 178.26 | 113.02 | 149.54 | 77.92 | 71.62 | 0.00 | 0.00 |
April | 134.06 | 92.29 | 111.97 | 36.42 | 75.55 | 0.00 | 0.00 |
May | 112.23 | 62.69 | 90.47 | 10.48 | 79.98 | 0.00 | 0.00 |
June | 117.22 | 46.61 | 83.64 | 4.62 | 79.02 | 0.00 | 0.00 |
July | 122.32 | 36.24 | 84.56 | 6.28 | 78.29 | 0.00 | 0.00 |
August | 147.52 | 34.63 | 100.97 | 18.84 | 82.13 | 0.00 | 0.00 |
September | 152.32 | 60.28 | 111.05 | 41.28 | 69.76 | 0.00 | 0.00 |
October | 217.51 | 111.16 | 161.04 | 104.33 | 56.72 | 0.00 | 0.00 |
November | 221.88 | 138.88 | 173.29 | 115.01 | 58.28 | 0.00 | 0.00 |
December | 207.65 | 166.01 | 175.67 | 123.60 | 52.08 | 0.00 | 0.00 |
Annual Sum or Average | 166.68 | 101.04 | 132.08 | 64.33 | 67.76 | 0.00 | 0.00 |
Minimum of Months | 112.23 | 34.63 | 83.64 | 4.62 | 52.08 | 0.00 | 0.00 |
Maximum of Months | 221.88 | 190.34 | 178.22 | 124.27 | 82.13 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.245767E+10 | 0.348290E+10 | 0.276216E+10 | 0.152662E+10 | 0.123554E+10 | 0.00 | 0.00 |
February | 0.321999E+10 | 0.276558E+10 | 0.311773E+10 | 0.193065E+10 | 0.118708E+10 | 0.00 | 0.00 |
March | 0.583167E+10 | 0.220061E+10 | 0.500872E+10 | 0.305806E+10 | 0.195066E+10 | 0.00 | 0.00 |
April | 0.768549E+10 | 0.173374E+10 | 0.609743E+10 | 0.375763E+10 | 0.233980E+10 | 0.00 | 0.00 |
May | 0.917361E+10 | 0.125257E+10 | 0.697884E+10 | 0.400395E+10 | 0.297490E+10 | 0.00 | 0.00 |
June | 0.988309E+10 | 0.921342E+09 | 0.720643E+10 | 0.421748E+10 | 0.298895E+10 | 0.00 | 0.00 |
July | 0.967804E+10 | 0.741966E+09 | 0.693388E+10 | 0.389342E+10 | 0.304046E+10 | 0.00 | 0.00 |
August | 0.897135E+10 | 0.711008E+09 | 0.638149E+10 | 0.346285E+10 | 0.291864E+10 | 0.00 | 0.00 |
September | 0.608992E+10 | 0.115726E+10 | 0.462229E+10 | 0.256769E+10 | 0.205460E+10 | 0.00 | 0.00 |
October | 0.493511E+10 | 0.208358E+10 | 0.409599E+10 | 0.275201E+10 | 0.134397E+10 | 0.00 | 0.00 |
November | 0.315168E+10 | 0.262744E+10 | 0.295238E+10 | 0.167148E+10 | 0.128089E+10 | 0.00 | 0.00 |
December | 0.230672E+10 | 0.321662E+10 | 0.249720E+10 | 0.136100E+10 | 0.113620E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.733843E+11 | 0.228946E+11 | 0.586545E+11 | 0.342028E+11 | 0.244517E+11 | 0.00 | 0.00 |
Minimum of Months | 0.230672E+10 | 0.711008E+09 | 0.249720E+10 | 0.136100E+10 | 0.113620E+10 | 0.00 | 0.00 |
Maximum of Months | 0.988309E+10 | 0.348290E+10 | 0.720643E+10 | 0.421748E+10 | 0.304046E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.259426E+10 | 0.257307E+10 | 0.231990E+10 | 0.161759E+10 | 0.702308E+09 | 0.00 | 0.00 |
February | 0.230993E+10 | 0.203121E+10 | 0.195567E+10 | 0.131108E+10 | 0.644589E+09 | 0.00 | 0.00 |
March | 0.230762E+10 | 0.161025E+10 | 0.194650E+10 | 0.101424E+10 | 0.932255E+09 | 0.00 | 0.00 |
April | 0.170811E+10 | 0.126231E+10 | 0.141053E+10 | 0.458839E+09 | 0.951695E+09 | 0.00 | 0.00 |
May | 0.154240E+10 | 0.874911E+09 | 0.117758E+10 | 0.136466E+09 | 0.104112E+10 | 0.00 | 0.00 |
June | 0.174358E+10 | 0.575771E+09 | 0.105366E+10 | 58231071.12 | 0.995429E+09 | 0.00 | 0.00 |
July | 0.191760E+10 | 0.444121E+09 | 0.110077E+10 | 81695334.73 | 0.101907E+10 | 0.00 | 0.00 |
August | 0.226833E+10 | 0.402273E+09 | 0.131433E+10 | 0.245192E+09 | 0.106914E+10 | 0.00 | 0.00 |
September | 0.206738E+10 | 0.767663E+09 | 0.139885E+10 | 0.520056E+09 | 0.878796E+09 | 0.00 | 0.00 |
October | 0.285999E+10 | 0.155372E+10 | 0.209624E+10 | 0.135799E+10 | 0.738250E+09 | 0.00 | 0.00 |
November | 0.278556E+10 | 0.190428E+10 | 0.218287E+10 | 0.144871E+10 | 0.734162E+09 | 0.00 | 0.00 |
December | 0.271772E+10 | 0.231277E+10 | 0.228670E+10 | 0.160885E+10 | 0.677853E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.268225E+11 | 0.163123E+11 | 0.202436E+11 | 0.985895E+10 | 0.103847E+11 | 0.00 | 0.00 |
Minimum of Months | 0.154240E+10 | 0.402273E+09 | 0.105366E+10 | 58231071.12 | 0.644589E+09 | 0.00 | 0.00 |
Maximum of Months | 0.285999E+10 | 0.257307E+10 | 0.231990E+10 | 0.161759E+10 | 0.106914E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.262093E+10 | 0.249175E+10 | 0.231990E+10 | 0.161759E+10 | 0.702308E+09 | 0.00 | 0.00 |
February | 0.232722E+10 | 0.195257E+10 | 0.195567E+10 | 0.131108E+10 | 0.644589E+09 | 0.00 | 0.00 |
March | 0.232955E+10 | 0.152693E+10 | 0.194650E+10 | 0.101424E+10 | 0.932255E+09 | 0.00 | 0.00 |
April | 0.171915E+10 | 0.119641E+10 | 0.141053E+10 | 0.458839E+09 | 0.951695E+09 | 0.00 | 0.00 |
May | 0.154206E+10 | 0.824311E+09 | 0.117758E+10 | 0.136466E+09 | 0.104112E+10 | 0.00 | 0.00 |
June | 0.173550E+10 | 0.537558E+09 | 0.105366E+10 | 58231071.12 | 0.995429E+09 | 0.00 | 0.00 |
July | 0.190939E+10 | 0.407653E+09 | 0.110077E+10 | 81695334.73 | 0.101907E+10 | 0.00 | 0.00 |
August | 0.225821E+10 | 0.365342E+09 | 0.131433E+10 | 0.245192E+09 | 0.106914E+10 | 0.00 | 0.00 |
September | 0.206072E+10 | 0.727618E+09 | 0.139885E+10 | 0.520056E+09 | 0.878796E+09 | 0.00 | 0.00 |
October | 0.286427E+10 | 0.148677E+10 | 0.209624E+10 | 0.135799E+10 | 0.738250E+09 | 0.00 | 0.00 |
November | 0.280371E+10 | 0.182309E+10 | 0.218287E+10 | 0.144871E+10 | 0.734162E+09 | 0.00 | 0.00 |
December | 0.274720E+10 | 0.220233E+10 | 0.228670E+10 | 0.160885E+10 | 0.677853E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.269179E+11 | 0.155423E+11 | 0.202436E+11 | 0.985895E+10 | 0.103847E+11 | 0.00 | 0.00 |
Minimum of Months | 0.154206E+10 | 0.365342E+09 | 0.105366E+10 | 58231071.12 | 0.644589E+09 | 0.00 | 0.00 |
Maximum of Months | 0.286427E+10 | 0.249175E+10 | 0.231990E+10 | 0.161759E+10 | 0.106914E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.525788E+09 | 0.509795E+09 | 0.477354E+09 | 0.332844E+09 | 0.144510E+09 | 0.00 | 0.00 |
February | 0.469805E+09 | 0.397496E+09 | 0.402408E+09 | 0.269774E+09 | 0.132634E+09 | 0.00 | 0.00 |
March | 0.477460E+09 | 0.302710E+09 | 0.400520E+09 | 0.208695E+09 | 0.191825E+09 | 0.00 | 0.00 |
April | 0.347483E+09 | 0.239222E+09 | 0.290238E+09 | 94412838.34 | 0.195825E+09 | 0.00 | 0.00 |
May | 0.300593E+09 | 0.167900E+09 | 0.242305E+09 | 28079908.65 | 0.214225E+09 | 0.00 | 0.00 |
June | 0.303828E+09 | 0.120808E+09 | 0.216806E+09 | 11981890.80 | 0.204824E+09 | 0.00 | 0.00 |
July | 0.327630E+09 | 97067116.40 | 0.226499E+09 | 16810004.70 | 0.209689E+09 | 0.00 | 0.00 |
August | 0.395112E+09 | 92757304.29 | 0.270442E+09 | 50451868.80 | 0.219990E+09 | 0.00 | 0.00 |
September | 0.394801E+09 | 0.156241E+09 | 0.287834E+09 | 0.107009E+09 | 0.180825E+09 | 0.00 | 0.00 |
October | 0.582590E+09 | 0.297736E+09 | 0.431332E+09 | 0.279427E+09 | 0.151906E+09 | 0.00 | 0.00 |
November | 0.575109E+09 | 0.359978E+09 | 0.449158E+09 | 0.298093E+09 | 0.151064E+09 | 0.00 | 0.00 |
December | 0.556178E+09 | 0.444647E+09 | 0.470522E+09 | 0.331044E+09 | 0.139478E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.525638E+10 | 0.318636E+10 | 0.416542E+10 | 0.202862E+10 | 0.213680E+10 | 0.00 | 0.00 |
Minimum of Months | 0.300593E+09 | 92757304.29 | 0.216806E+09 | 11981890.80 | 0.132634E+09 | 0.00 | 0.00 |
Maximum of Months | 0.582590E+09 | 0.509795E+09 | 0.477354E+09 | 0.332844E+09 | 0.219990E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 3.96 | 1.45 | -3.0 | 4.56 | -7.9 | 48.74 | 150.20 | 0.00 |
February | 7.94 | 4.23 | -1.3 | 5.19 | -4.0 | 51.84 | 169.20 | 0.00 |
March | 13.76 | 8.96 | 3.80 | 4.89 | 2.24 | 76.95 | 193.22 | 0.00 |
April | 17.21 | 12.53 | 8.82 | 3.95 | 6.45 | 95.37 | 211.82 | 0.00 |
May | 20.84 | 16.43 | 13.69 | 3.50 | 11.45 | 117.34 | 200.00 | 0.00 |
June | 24.80 | 19.34 | 16.45 | 3.85 | 15.08 | 121.81 | 213.08 | 0.00 |
July | 26.06 | 21.67 | 19.85 | 3.24 | 17.63 | 119.92 | 194.46 | 0.00 |
August | 26.55 | 22.41 | 20.72 | 3.39 | 18.20 | 115.12 | 179.15 | 0.00 |
September | 22.53 | 18.74 | 16.82 | 3.06 | 13.43 | 83.74 | 156.58 | 0.02 |
October | 16.03 | 13.01 | 10.77 | 4.05 | 5.85 | 53.01 | 190.38 | 0.00 |
November | 11.94 | 8.21 | 4.17 | 4.16 | 0.29 | 52.20 | 150.38 | 0.00 |
December | 7.70 | 4.67 | 0.26 | 4.69 | -4.1 | 44.81 | 142.03 | 0.00 |
Annual Sum or Average | 16.65 | 12.68 | 9.31 | 4.04 | 6.28 | 81.91 | 179.25 | 0.00 |
Minimum of Months | 3.96 | 1.45 | -3.0 | 3.06 | -7.9 | 44.81 | 142.03 | 0.00 |
Maximum of Months | 26.55 | 22.41 | 20.72 | 5.19 | 18.20 | 121.81 | 213.08 | 0.02 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.10 | 31-JAN-14:00 | 12.95 | 6.70 | 5.70 | 12.22 | 200.50 | 90.50 |
February | 25.00 | 26-FEB-14:00 | 12.72 | 1.70 | 4.10 | 8.15 | 91.50 | 816.00 |
March | 27.80 | 30-MAR-13:00 | 17.85 | 12.20 | 5.70 | 16.30 | 231.50 | 710.50 |
April | 28.90 | 17-APR-14:20 | 16.53 | 8.13 | 2.03 | 13.35 | 125.83 | 887.67 |
May | 30.60 | 19-MAY-13:00 | 18.47 | 11.70 | 4.60 | 15.76 | 140.00 | 875.50 |
June | 34.40 | 06-JUN-14:00 | 22.37 | 17.20 | 8.20 | 22.13 | 251.00 | 561.00 |
July | 36.70 | 08-JUL-14:00 | 23.89 | 18.90 | 2.10 | 24.66 | 274.00 | 567.00 |
August | 35.00 | 01-AUG-14:00 | 23.82 | 19.40 | 2.60 | 26.15 | 306.00 | 508.00 |
September | 31.70 | 07-SEP-15:09 | 23.04 | 19.60 | 4.02 | 22.55 | 218.67 | 591.33 |
October | 30.00 | 10-OCT-15:00 | 20.54 | 16.10 | 3.60 | 17.57 | 97.00 | 561.00 |
November | 24.40 | 05-NOV-15:00 | 17.94 | 14.40 | 2.10 | 14.10 | 117.50 | 361.50 |
December | 22.80 | 12-DEC-14:20 | 16.76 | 13.33 | 5.20 | 13.35 | 144.17 | 433.83 |
Annual Sum or Average | ||||||||
Minimum of Months | 21.10 | 12.72 | 1.70 | 2.03 | 8.15 | 91.50 | 90.50 | |
Maximum of Months | 36.70 | 23.89 | 19.60 | 8.20 | 26.15 | 306.00 | 887.67 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.7 | 14-JAN-06:10 | -7.7 | -10.6 | 4.95 | -24.7 | 0.00 | 0.00 |
February | -12.8 | 12-FEB-06:00 | -13.7 | -18.3 | 7.20 | -30.1 | 0.00 | 0.00 |
March | 1.10 | 19-MAR-06:00 | -1.4 | -6.1 | 0.00 | -16.2 | 17.00 | 290.50 |
April | 0.00 | 06-APR-04:00 | -1.0 | -2.8 | 3.10 | -16.5 | 0.00 | 0.00 |
May | 7.80 | 11-MAY-05:00 | 5.44 | 2.80 | 4.10 | -7.8 | 21.50 | 204.50 |
June | 11.10 | 10-JUN-04:00 | 8.73 | 6.70 | 0.00 | -2.5 | 0.00 | 0.00 |
July | 17.20 | 28-JUL-22:00 | 16.88 | 16.70 | 4.10 | 14.28 | 0.00 | 0.00 |
August | 18.30 | 25-AUG-05:00 | 17.20 | 16.70 | 3.60 | 5.13 | 0.00 | 0.00 |
September | 11.70 | 29-SEP-03:00 | 11.07 | 10.60 | 2.60 | -2.3 | 0.00 | 0.00 |
October | 2.20 | 26-OCT-04:00 | 1.95 | 1.70 | 3.10 | -13.4 | 0.00 | 0.00 |
November | -3.3 | 22-NOV-05:00 | -4.0 | -5.6 | 5.20 | -20.2 | 0.00 | 0.00 |
December | -5.6 | 18-DEC-07:00 | -7.1 | -11.7 | 2.60 | -22.7 | 17.00 | 320.50 |
Annual Sum or Average | ||||||||
Minimum of Months | -12.8 | -13.7 | -18.3 | 0.00 | -30.1 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 17.20 | 16.70 | 7.20 | 14.28 | 21.50 | 320.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 16.51 | 19-JAN-21:00 | 18.30 | 15.60 | 8.80 | 15.21 | 0.00 | 0.00 |
February | 15.80 | 18-FEB-15:00 | 17.20 | 15.00 | 5.20 | 13.91 | 73.00 | 1.00 |
March | 18.15 | 30-MAR-12:30 | 25.85 | 13.85 | 5.45 | 15.39 | 323.00 | 600.00 |
April | 20.00 | 04-APR-13:00 | 25.00 | 17.80 | 9.30 | 18.64 | 307.00 | 197.50 |
May | 22.33 | 30-MAY-17:00 | 27.80 | 20.00 | 4.10 | 21.96 | 97.50 | 79.50 |
June | 24.31 | 23-JUN-11:39 | 31.13 | 21.87 | 4.83 | 22.98 | 338.17 | 565.17 |
July | 25.05 | 07-JUL-11:00 | 33.30 | 22.20 | 3.60 | 20.75 | 116.50 | 900.00 |
August | 25.12 | 19-AUG-16:00 | 30.00 | 23.30 | 3.10 | 23.66 | 197.00 | 136.50 |
September | 24.09 | 09-SEP-10:00 | 30.60 | 21.70 | 2.60 | 21.27 | 236.00 | 482.00 |
October | 23.19 | 18-OCT-15:00 | 25.60 | 22.20 | 5.70 | 23.82 | 159.00 | 2.00 |
November | 18.87 | 19-NOV-14:00 | 24.40 | 16.10 | 8.20 | 13.91 | 143.00 | 384.50 |
December | 17.57 | 13-DEC-10:00 | 19.40 | 16.70 | 4.60 | 14.47 | 227.50 | 77.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.80 | 17.20 | 13.85 | 2.60 | 13.91 | 0.00 | 0.00 | |
Maximum of Months | 25.12 | 33.30 | 23.30 | 9.30 | 23.82 | 338.17 | 900.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 15.60 | 19-JAN-17:00 | 17.20 | 16.13 | 6.70 | 14.10 | 0.00 | 0.00 |
February | 15.00 | 18-FEB-16:19 | 17.20 | 15.80 | 5.53 | 13.91 | 50.33 | 1.00 |
March | 16.10 | 31-MAR-10:00 | 21.70 | 18.06 | 13.90 | 18.64 | 268.00 | 8.00 |
April | 17.80 | 04-APR-09:20 | 20.77 | 18.74 | 7.53 | 16.78 | 242.00 | 111.50 |
May | 20.60 | 30-MAY-19:00 | 25.00 | 21.79 | 2.60 | 12.41 | 0.00 | 0.00 |
June | 22.80 | 18-JUN-16:00 | 28.30 | 24.23 | 0.00 | 24.66 | 140.50 | 115.50 |
July | 23.30 | 26-JUL-09:00 | 26.10 | 24.09 | 3.60 | 24.66 | 338.00 | 251.50 |
August | 23.90 | 08-AUG-19:00 | 26.10 | 24.51 | 1.50 | 24.83 | 0.00 | 0.00 |
September | 23.30 | 16-SEP-16:00 | 25.60 | 23.88 | 2.10 | 22.13 | 108.00 | 57.50 |
October | 22.20 | 18-OCT-14:00 | 25.00 | 23.04 | 4.60 | 23.32 | 234.50 | 2.00 |
November | 17.20 | 04-NOV-13:00 | 17.80 | 17.48 | 3.60 | 15.02 | 276.50 | 2.50 |
December | 16.70 | 13-DEC-16:19 | 17.03 | 16.82 | 2.93 | 14.10 | 54.00 | 4.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.00 | 17.03 | 15.80 | 0.00 | 12.41 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 28.30 | 24.51 | 13.90 | 24.83 | 338.00 | 251.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 13.74 | 22.89 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 13.65 | 27.55 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 15.17 | 38.46 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 17.98 | 47.59 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 21.32 | 52.44 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 24.28 | 55.84 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 26.07 | 52.33 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 26.20 | 48.31 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 24.63 | 36.35 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 21.78 | 31.91 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 18.45 | 24.33 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 15.51 | 20.76 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.94 | 38.29 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 13.65 | 20.76 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 26.20 | 55.84 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.257130E+10 | -.214396E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -427342386.9 | 58.99 | 0.00 | 0.00 |
February | 0.233323E+10 | -.195631E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -376928565.7 | 58.99 | 0.00 | 0.00 |
March | 0.254555E+10 | -.214514E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -400408037.6 | 58.99 | 0.00 | 0.00 |
April | 0.228775E+10 | -.190924E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -378502700.9 | 58.99 | 0.00 | 0.00 |
May | 0.220030E+10 | -.181625E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -384049675.5 | 58.99 | 0.00 | 0.00 |
June | 0.200717E+10 | -.164082E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -366351078.1 | 58.99 | 0.00 | 0.00 |
July | 0.193751E+10 | -.156098E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -376526369.2 | 58.99 | 0.00 | 0.00 |
August | 0.198150E+10 | -.160534E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -376156951.2 | 58.99 | 0.00 | 0.00 |
September | 0.196861E+10 | -.160071E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -367902106.4 | 59.00 | 0.00 | 0.00 |
October | 0.215299E+10 | -.176384E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -389151012.1 | 58.99 | 0.00 | 0.00 |
November | 0.223855E+10 | -.185069E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -387856579.5 | 58.99 | 0.00 | 0.00 |
December | 0.247938E+10 | -.206166E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -417719902.1 | 59.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.267038E+11 | -.220549E+11 | 8760.00 | -.464890E+10 | 58.99 | |||||
Minimum of Months | 0.193751E+10 | -.214514E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -427342386.9 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.257130E+10 | -.156098E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -366351078.1 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN}[] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 290.67 | 0.85 | 0.50 | 08-JAN-11:20 | 264.44 | 7.01 | 0.00 | 15.00 | 218.84 | 5.57 | 0.00 | 4.00 |
February | 263.00 | 0.84 | 0.50 | 09-FEB-13:20 | 285.41 | 6.96 | 0.00 | 35.83 | 233.52 | 5.42 | 0.00 | 13.00 |
March | 351.67 | 0.77 | 0.50 | 01-MAR-13:20 | 382.95 | 8.91 | 0.00 | 97.83 | 316.96 | 7.33 | 0.00 | 60.17 |
April | 369.33 | 0.73 | 0.50 | 01-APR-11:09 | 2610.78 | 10.12 | 0.00 | 145.67 | 2728.39 | 8.44 | 0.00 | 103.83 |
May | 407.00 | 0.71 | 0.50 | 01-MAY-09:20 | 474.26 | 11.91 | 0.00 | 171.00 | 398.86 | 10.19 | 0.00 | 116.33 |
June | 411.67 | 0.71 | 0.50 | 01-JUN-09:39 | 471.33 | 12.34 | 0.00 | 173.50 | 395.39 | 10.61 | 0.00 | 114.33 |
July | 411.00 | 0.71 | 0.50 | 01-JUL-09:20 | 483.09 | 12.27 | 0.00 | 183.50 | 405.55 | 10.60 | 0.00 | 128.17 |
August | 390.50 | 0.69 | 0.50 | 01-AUG-11:39 | 629.31 | 11.88 | 0.00 | 196.17 | 469.25 | 10.14 | 0.00 | 136.67 |
September | 298.50 | 0.72 | 0.50 | 01-SEP-09:00 | 3142.88 | 9.77 | 0.00 | 161.17 | 2200.34 | 8.13 | 0.00 | 80.00 |
October | 293.50 | 0.82 | 0.50 | 01-OCT-11:09 | 305.48 | 6.91 | 0.00 | 39.00 | 268.35 | 5.43 | 0.00 | 21.83 |
November | 299.00 | 0.82 | 0.50 | 02-NOV-10:00 | 311.90 | 7.35 | 0.00 | 14.50 | 626.88 | 5.89 | 0.00 | 35.67 |
December | 285.17 | 0.85 | 0.58 | 11-DEC-13:09 | 1344.06 | 6.94 | 0.00 | 44.00 | 205.12 | 5.47 | 0.00 | 0.00 |
Annual Sum or Average | 4071.00 | 0.76 | 881.00 | 9.70 | 0.00 | 1277.17 | 712.53 | 8.08 | 0.00 | 814.00 | ||
Minimum of Months | 263.00 | 0.69 | 0.50 | 264.44 | 6.91 | 0.00 | 14.50 | 205.12 | 5.42 | 0.00 | 0.00 | |
Maximum of Months | 411.67 | 0.85 | 0.58 | 3142.88 | 12.34 | 0.00 | 196.17 | 2728.39 | 10.61 | 0.00 | 136.67 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.836546E+10 | 49958.87 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.453371E+10 | 49958.87 | 02-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.330243E+09 | 34525.72 | 23-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 56895686.42 | 8245.75 | 07-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 11519600.16 | 3752.22 | 26-OCT-06:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.384119E+09 | 49807.77 | 22-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.273696E+10 | 49958.87 | 02-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.164189E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.836546E+10 | 49958.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.362432E+10 | 227212.53 | 08-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136144E+10 | 227212.53 | 12-FEB-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.330849E+09 | 86990.32 | 04-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.531661E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.362432E+10 | 227212.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.230991E+10 | 30821.08 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.124193E+10 | 30821.08 | 03-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 89712376.76 | 7672.03 | 23-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 36964416.01 | 3541.60 | 07-APR-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6185416.06 | 2093.78 | 26-OCT-06:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 75576883.50 | 10399.11 | 22-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.598499E+09 | 30821.08 | 26-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.435878E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.230991E+10 | 30821.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.418012E+10 | 25048.67 | 01-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.241350E+10 | 25048.67 | 02-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.379867E+09 | 18217.82 | 23-MAR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.111794E+09 | 14544.91 | 06-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 228357.88 | 317.12 | 11-MAY-06:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 62142106.26 | 4626.44 | 26-OCT-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.265431E+09 | 20381.74 | 21-NOV-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.150682E+10 | 25048.67 | 03-DEC-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.891990E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.418012E+10 | 25048.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: FRONT_ENTRY UNIT HEATER COIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.101257E+11 | 30008.94 | 07-JAN-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.587924E+10 | 29963.19 | 11-FEB-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.209484E+10 | 17392.21 | 22-MAR-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.573450E+09 | 12180.04 | 05-APR-11:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 11772631.09 | 1694.69 | 10-MAY-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 30024210.11 | 1768.69 | 28-SEP-17:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.906096E+09 | 11027.81 | 25-OCT-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.218132E+10 | 17577.33 | 20-NOV-12:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.587371E+10 | 21678.85 | 17-DEC-18:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.276761E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.101257E+11 | 30008.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 1767.99 | 1235.02 | 0.55 | 20-JAN-15:40 | 0.38 | 0.00 |
February | 0.00 | 0.00 | 0.173896E+09 | 0.173896E+09 | 5931.04 | 28-FEB-15:10 | 5931.04 | 0.00 |
March | 0.00 | 0.00 | 0.131707E+10 | 0.102947E+10 | 24007.43 | 31-MAR-06:02 | 13708.07 | 0.00 |
April | 0.00 | 0.00 | 0.460328E+10 | 0.378786E+10 | 24982.02 | 19-APR-06:02 | 15566.04 | 0.00 |
May | 0.00 | 0.00 | 0.113667E+11 | 0.847418E+10 | 39397.92 | 26-MAY-06:02 | 18379.63 | 0.00 |
June | 0.00 | 0.00 | 0.207902E+11 | 0.153219E+11 | 40322.63 | 23-JUN-06:02 | 24209.65 | 0.00 |
July | 0.00 | 0.00 | 0.250082E+11 | 0.174432E+11 | 40873.55 | 30-JUL-08:62 | 21619.76 | 0.00 |
August | 0.00 | 0.00 | 0.272256E+11 | 0.187010E+11 | 41516.82 | 20-AUG-07:03 | 22413.86 | 0.00 |
September | 0.00 | 0.00 | 0.161275E+11 | 0.113633E+11 | 41225.93 | 17-SEP-08:62 | 21427.66 | 0.00 |
October | 0.00 | 0.00 | 0.494318E+10 | 0.351399E+10 | 40428.05 | 19-OCT-06:02 | 16662.93 | 0.00 |
November | 0.00 | 0.00 | 0.654478E+09 | 0.462045E+09 | 21262.36 | 04-NOV-06:02 | 11607.54 | 0.00 |
December | 0.00 | 0.00 | 52225520.65 | 36617211.18 | 3781.69 | 12-DEC-15:10 | 2853.79 | 0.00 |
Annual Sum or Average | 0.112262E+12 | 0.803075E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 1767.99 | 1235.02 | 0.55 | 0.38 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.272256E+11 | 0.187010E+11 | 41516.82 | 24209.65 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.151521E+10 | 0.120758E+10 | 19364.52 | 20-JAN-13:10 | 12423.40 | 0.00 |
February | 0.00 | 0.00 | 0.497973E+10 | 0.443759E+10 | 37199.73 | 28-FEB-15:10 | 36344.11 | 0.00 |
March | 0.00 | 0.00 | 0.174848E+11 | 0.140438E+11 | 185330.41 | 30-MAR-06:02 | 109746.21 | 0.00 |
April | 0.00 | 0.00 | 0.353747E+11 | 0.283296E+11 | 187573.51 | 23-APR-08:62 | 100340.33 | 0.00 |
May | 0.00 | 0.00 | 0.637674E+11 | 0.479633E+11 | 190509.70 | 31-MAY-06:02 | 137714.93 | 0.00 |
June | 0.00 | 0.00 | 0.860205E+11 | 0.638871E+11 | 192258.45 | 19-JUN-06:02 | 133513.05 | 0.00 |
July | 0.00 | 0.00 | 0.983115E+11 | 0.692816E+11 | 195265.74 | 30-JUL-08:62 | 125238.62 | 0.00 |
August | 0.00 | 0.00 | 0.103309E+12 | 0.716597E+11 | 193688.21 | 12-AUG-06:02 | 129674.71 | 0.00 |
September | 0.00 | 0.00 | 0.706488E+11 | 0.501849E+11 | 195772.05 | 17-SEP-08:62 | 123268.01 | 0.00 |
October | 0.00 | 0.00 | 0.334245E+11 | 0.247610E+11 | 195033.12 | 19-OCT-06:02 | 124820.46 | 0.00 |
November | 0.00 | 0.00 | 0.130865E+11 | 0.104266E+11 | 184277.06 | 04-NOV-06:02 | 103070.70 | 0.00 |
December | 0.00 | 0.00 | 0.649158E+10 | 0.530457E+10 | 152958.41 | 13-DEC-07:03 | 86651.00 | 0.00 |
Annual Sum or Average | 0.534414E+12 | 0.391487E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.151521E+10 | 0.120758E+10 | 19364.52 | 12423.40 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.103309E+12 | 0.716597E+11 | 195772.05 | 137714.93 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 51522900.08 | 42538816.24 | 3160.90 | 31-JAN-14:50 | 2813.70 | 0.00 |
February | 0.00 | 0.00 | 0.816931E+09 | 0.811357E+09 | 7963.59 | 28-FEB-15:10 | 7963.59 | 0.00 |
March | 0.00 | 0.00 | 0.245334E+10 | 0.201130E+10 | 23972.72 | 30-MAR-06:02 | 13978.83 | 0.00 |
April | 0.00 | 0.00 | 0.504264E+10 | 0.420386E+10 | 23177.55 | 19-APR-06:02 | 14673.23 | 0.00 |
May | 0.00 | 0.00 | 0.934655E+10 | 0.711403E+10 | 25000.88 | 31-MAY-06:02 | 12227.18 | 0.00 |
June | 0.00 | 0.00 | 0.146402E+11 | 0.108625E+11 | 25746.67 | 26-JUN-05:03 | 16459.20 | 0.00 |
July | 0.00 | 0.00 | 0.175198E+11 | 0.122808E+11 | 26032.46 | 30-JUL-08:62 | 13596.05 | 0.00 |
August | 0.00 | 0.00 | 0.196384E+11 | 0.136538E+11 | 26504.71 | 20-AUG-07:03 | 14327.25 | 0.00 |
September | 0.00 | 0.00 | 0.131085E+11 | 0.948708E+10 | 26014.26 | 17-SEP-08:62 | 13758.93 | 0.00 |
October | 0.00 | 0.00 | 0.622673E+10 | 0.481851E+10 | 25663.13 | 19-OCT-06:02 | 10511.96 | 0.00 |
November | 0.00 | 0.00 | 0.237931E+10 | 0.196289E+10 | 23685.42 | 04-NOV-06:02 | 13429.39 | 0.00 |
December | 0.00 | 0.00 | 0.517292E+09 | 0.371841E+09 | 20734.08 | 13-DEC-07:03 | 11877.69 | 0.00 |
Annual Sum or Average | 0.917412E+11 | 0.676205E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 51522900.08 | 42538816.24 | 3160.90 | 2813.70 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.196384E+11 | 0.136538E+11 | 26504.71 | 16459.20 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 7835039.20 | 6532099.18 | 1044.94 | 31-JAN-15:10 | 898.94 | 0.00 |
February | 0.00 | 0.00 | 0.444273E+09 | 0.442489E+09 | 5483.94 | 28-FEB-15:10 | 5483.94 | 0.00 |
March | 0.00 | 0.00 | 0.130283E+10 | 0.102962E+10 | 15380.69 | 31-MAR-06:02 | 8684.64 | 0.00 |
April | 0.00 | 0.00 | 0.299591E+10 | 0.243529E+10 | 9209.30 | 19-APR-06:02 | 5564.30 | 0.00 |
May | 0.00 | 0.00 | 0.618950E+10 | 0.450574E+10 | 20440.81 | 31-MAY-06:02 | 9805.89 | 0.00 |
June | 0.00 | 0.00 | 0.113148E+11 | 0.794424E+10 | 21019.69 | 23-JUN-06:02 | 11403.39 | 0.00 |
July | 0.00 | 0.00 | 0.138910E+11 | 0.918375E+10 | 21367.04 | 30-JUL-08:62 | 10041.42 | 0.00 |
August | 0.00 | 0.00 | 0.159321E+11 | 0.104125E+11 | 21631.35 | 20-AUG-07:03 | 11029.44 | 0.00 |
September | 0.00 | 0.00 | 0.986121E+10 | 0.673778E+10 | 21470.92 | 17-SEP-08:62 | 10395.53 | 0.00 |
October | 0.00 | 0.00 | 0.431966E+10 | 0.318580E+10 | 21001.12 | 19-OCT-06:02 | 8503.02 | 0.00 |
November | 0.00 | 0.00 | 0.122405E+10 | 0.990156E+09 | 10036.66 | 04-NOV-06:02 | 5376.90 | 0.00 |
December | 0.00 | 0.00 | 0.226532E+09 | 0.155829E+09 | 6779.79 | 12-DEC-14:00 | 4939.19 | 0.00 |
Annual Sum or Average | 0.677096E+11 | 0.470297E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 7835039.20 | 6532099.18 | 1044.94 | 898.94 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.159321E+11 | 0.104125E+11 | 21631.35 | 11403.39 | 0.00 |
Report: FanReportMonthly
For: FRONT_ENTRY UNIT HEATERFAN
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.286174E+10 | 0.50 | 1942.45 | 01-JAN-07:03 | 0.91 |
February | 0.218801E+10 | 0.42 | 1942.45 | 01-FEB-06:02 | 0.91 |
March | 0.177686E+10 | 0.31 | 1942.45 | 01-MAR-08:70 | 0.91 |
April | 0.824349E+09 | 0.15 | 1942.45 | 01-APR-07:10 | 0.91 |
May | 0.211985E+09 | 0.04 | 1942.45 | 01-MAY-07:10 | 0.90 |
June | 10576639.15 | 0.00 | 1942.45 | 07-JUN-07:07 | 0.90 |
July | 57690759.01 | 0.01 | 1942.45 | 28-JUL-11:10 | 0.89 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.146050E+09 | 0.03 | 1942.45 | 14-SEP-07:05 | 0.90 |
October | 0.107810E+10 | 0.19 | 1942.45 | 01-OCT-11:10 | 0.89 |
November | 0.176528E+10 | 0.32 | 1942.45 | 01-NOV-07:10 | 0.91 |
December | 0.255180E+10 | 0.45 | 1942.45 | 01-DEC-05:40 | 0.91 |
Annual Sum or Average | 0.134724E+11 | 0.20 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.286174E+10 | 0.50 | 1942.45 | 0.91 |
Report: FanReportMonthly
For: PSZ-AC:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.153024E+10 | 0.37 | 2059.91 | 01-JAN-08:62 | 0.91 |
February | 0.131277E+10 | 0.35 | 2059.91 | 02-FEB-06:02 | 0.91 |
March | 0.135193E+10 | 0.34 | 1678.11 | 23-MAR-06:03 | 0.83 |
April | 0.129179E+10 | 0.33 | 1282.91 | 19-APR-06:02 | 0.71 |
May | 0.133485E+10 | 0.33 | 2059.91 | 06-MAY-06:02 | 0.90 |
June | 0.132643E+10 | 0.34 | 2059.91 | 01-JUN-06:02 | 0.90 |
July | 0.140755E+10 | 0.34 | 2059.91 | 01-JUL-06:02 | 0.90 |
August | 0.144246E+10 | 0.35 | 2059.91 | 01-AUG-06:02 | 0.90 |
September | 0.130389E+10 | 0.33 | 2059.91 | 01-SEP-06:02 | 0.90 |
October | 0.132144E+10 | 0.33 | 2059.91 | 02-OCT-06:02 | 0.90 |
November | 0.128206E+10 | 0.33 | 2056.17 | 22-NOV-06:02 | 0.91 |
December | 0.139067E+10 | 0.34 | 2059.91 | 02-DEC-06:02 | 0.91 |
Annual Sum or Average | 0.162961E+11 | 0.34 | |||
Minimum of Months | 0.128206E+10 | 0.33 | 1282.91 | 0.71 | |
Maximum of Months | 0.153024E+10 | 0.37 | 2059.91 | 0.91 |
Report: FanReportMonthly
For: PSZ-AC:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.842663E+10 | 0.52 | 12956.65 | 08-JAN-08:61 | 1.43 |
February | 0.758424E+10 | 0.52 | 12956.65 | 12-FEB-08:61 | 1.44 |
March | 0.845550E+10 | 0.53 | 12956.65 | 29-MAR-06:03 | 1.42 |
April | 0.812961E+10 | 0.52 | 12956.65 | 13-APR-06:03 | 1.42 |
May | 0.840767E+10 | 0.52 | 12956.65 | 02-MAY-06:03 | 1.42 |
June | 0.821714E+10 | 0.52 | 12956.65 | 01-JUN-06:02 | 1.42 |
July | 0.838867E+10 | 0.52 | 12956.65 | 01-JUL-06:02 | 1.42 |
August | 0.851955E+10 | 0.52 | 12956.65 | 01-AUG-06:02 | 1.42 |
September | 0.815811E+10 | 0.52 | 12956.65 | 01-SEP-06:02 | 1.42 |
October | 0.831812E+10 | 0.52 | 12956.65 | 01-OCT-08:62 | 1.42 |
November | 0.800654E+10 | 0.52 | 12956.65 | 04-NOV-06:02 | 1.42 |
December | 0.833337E+10 | 0.52 | 10331.51 | 13-DEC-07:03 | 1.28 |
Annual Sum or Average | 0.989452E+11 | 0.52 | |||
Minimum of Months | 0.758424E+10 | 0.52 | 10331.51 | 1.28 | |
Maximum of Months | 0.851955E+10 | 0.53 | 12956.65 | 1.44 |
Report: FanReportMonthly
For: PSZ-AC:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.858330E+09 | 0.36 | 1250.78 | 02-JAN-06:01 | 0.94 |
February | 0.758340E+09 | 0.35 | 1250.78 | 03-FEB-06:01 | 0.95 |
March | 0.818275E+09 | 0.35 | 1250.78 | 30-MAR-06:02 | 0.93 |
April | 0.784719E+09 | 0.34 | 1250.78 | 18-APR-06:02 | 0.93 |
May | 0.811182E+09 | 0.34 | 1250.78 | 03-MAY-06:02 | 0.93 |
June | 0.837142E+09 | 0.36 | 1250.78 | 01-JUN-06:02 | 0.93 |
July | 0.906775E+09 | 0.36 | 1250.78 | 01-JUL-06:02 | 0.93 |
August | 0.968498E+09 | 0.38 | 1250.78 | 01-AUG-06:02 | 0.93 |
September | 0.824343E+09 | 0.35 | 1250.78 | 01-SEP-06:02 | 0.93 |
October | 0.809234E+09 | 0.34 | 1250.78 | 02-OCT-06:02 | 0.93 |
November | 0.774660E+09 | 0.34 | 1250.78 | 04-NOV-06:02 | 0.93 |
December | 0.817960E+09 | 0.35 | 1250.78 | 26-DEC-06:01 | 0.94 |
Annual Sum or Average | 0.996946E+10 | 0.35 | |||
Minimum of Months | 0.758340E+09 | 0.34 | 1250.78 | 0.93 | |
Maximum of Months | 0.968498E+09 | 0.38 | 1250.78 | 0.95 |
Report: FanReportMonthly
For: PSZ-AC:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.715336E+09 | 0.38 | 963.92 | 01-JAN-08:62 | 0.94 |
February | 0.617266E+09 | 0.37 | 963.92 | 02-FEB-06:02 | 0.94 |
March | 0.637593E+09 | 0.35 | 806.20 | 23-MAR-06:03 | 0.87 |
April | 0.606378E+09 | 0.34 | 721.39 | 06-APR-06:03 | 0.82 |
May | 0.623986E+09 | 0.34 | 963.92 | 07-MAY-08:62 | 0.93 |
June | 0.641682E+09 | 0.35 | 963.92 | 01-JUN-06:02 | 0.93 |
July | 0.699525E+09 | 0.36 | 963.92 | 01-JUL-06:02 | 0.93 |
August | 0.749123E+09 | 0.38 | 963.92 | 01-AUG-06:02 | 0.93 |
September | 0.635781E+09 | 0.35 | 963.92 | 01-SEP-06:02 | 0.93 |
October | 0.624791E+09 | 0.34 | 963.92 | 09-OCT-08:62 | 0.93 |
November | 0.601600E+09 | 0.34 | 856.16 | 21-NOV-07:03 | 0.90 |
December | 0.653856E+09 | 0.35 | 963.92 | 03-DEC-08:61 | 0.95 |
Annual Sum or Average | 0.780692E+10 | 0.36 | |||
Minimum of Months | 0.601600E+09 | 0.34 | 721.39 | 0.82 | |
Maximum of Months | 0.749123E+09 | 0.38 | 963.92 | 0.95 |
Report: ZoneTemperatureOscillationReportMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.56 | 0.00 |
February | 0.54 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.42 | 2.45 |
July | 0.38 | 0.00 |
August | 0.21 | 0.00 |
September | 0.04 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 2.14 | 0.48 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.56 | 2.45 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.17 | 25.84 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.25 | 0.00 |
July | 0.38 | 0.00 |
August | 0.21 | 0.00 |
September | 0.17 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 1.17 | 3.69 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.38 | 25.84 |
Report: ZoneTemperatureOscillationReportMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.16 | 0.00 |
February | 0.32 | 0.64 |
March | 0.92 | 2.44 |
April | 0.94 | 1.72 |
May | 0.61 | 1.33 |
June | 1.08 | 0.00 |
July | 1.71 | 0.00 |
August | 1.54 | 0.00 |
September | 0.83 | 0.00 |
October | 0.68 | 1.19 |
November | 0.25 | 2.44 |
December | 0.42 | 1.46 |
Annual Sum or Average | 9.47 | 0.73 |
Minimum of Months | 0.16 | 0.00 |
Maximum of Months | 1.71 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.43 | 0.24 |
February | 0.29 | 0.00 |
March | 0.50 | 2.44 |
April | 0.72 | 2.44 |
May | 0.42 | 2.44 |
June | 0.33 | 0.61 |
July | 0.38 | 0.00 |
August | 0.62 | 0.00 |
September | 0.75 | 0.81 |
October | 0.49 | 1.81 |
November | 0.22 | 2.44 |
December | 0.08 | 2.44 |
Annual Sum or Average | 5.23 | 1.25 |
Minimum of Months | 0.08 | 0.00 |
Maximum of Months | 0.75 | 2.44 |
Report: ZoneTemperatureOscillationReportMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 35.22 | 0.00 |
February | 28.80 | 0.00 |
March | 21.14 | 0.00 |
April | 24.07 | 0.00 |
May | 10.78 | 0.00 |
June | 5.08 | 0.00 |
July | 4.67 | 0.00 |
August | 2.92 | 0.00 |
September | 6.23 | 0.00 |
October | 22.35 | 0.00 |
November | 26.33 | 0.00 |
December | 18.25 | 0.00 |
Annual Sum or Average | 205.83 | 0.00 |
Minimum of Months | 2.92 | 0.00 |
Maximum of Months | 35.22 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.153024E+10 | 0.104568E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.136103E+10 | 0.566714E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.170173E+10 | 0.412803E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.250696E+10 | 71119608.02 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.421697E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.647053E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.753119E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.801554E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.523267E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.255500E+10 | 14399500.20 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.145502E+10 | 0.480149E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.140497E+10 | 0.342119E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.439818E+11 | 0.205236E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.136103E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.801554E+10 | 0.104568E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.889002E+10 | 0.453040E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.908460E+10 | 0.170180E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.135728E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.183470E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.265112E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.329967E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.365331E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.378263E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.280316E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.178156E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.118636E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.102919E+11 | 0.413561E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.251764E+12 | 0.664576E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.889002E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.378263E+11 | 0.453040E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.872004E+09 | 0.288739E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.964435E+09 | 0.155241E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.142963E+10 | 0.112140E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.204967E+10 | 46205520.01 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.310834E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.441956E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.516672E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.568006E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.392685E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.228059E+10 | 7731770.08 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.135919E+10 | 94471104.37 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.944991E+09 | 0.748124E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.322020E+11 | 0.544848E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.872004E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.568006E+10 | 0.288739E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.717500E+09 | 0.522515E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.731679E+09 | 0.301688E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.970134E+09 | 0.474834E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.137956E+10 | 0.139742E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.217574E+10 | 285447.35 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.341360E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.406780E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.455182E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.298084E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.165493E+10 | 77677632.83 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.910044E+09 | 0.331789E+09 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.710838E+09 | 0.188352E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.242645E+11 | 0.111499E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.710838E+09 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.455182E+10 | 0.522515E+10 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.153024E+10 | 1767.99 | 0.836546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.131277E+10 | 0.173896E+09 | 0.453371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.135193E+10 | 0.131707E+10 | 0.330243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129179E+10 | 0.460328E+10 | 56895686.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.133485E+10 | 0.113667E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.132643E+10 | 0.207902E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.140755E+10 | 0.250082E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.144246E+10 | 0.272256E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.130389E+10 | 0.161275E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.132144E+10 | 0.494318E+10 | 11519600.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128206E+10 | 0.654478E+09 | 0.384119E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.139067E+10 | 52225520.65 | 0.273696E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.162961E+11 | 0.112262E+12 | 0.164189E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.128206E+10 | 1767.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.153024E+10 | 0.272256E+11 | 0.836546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.842663E+10 | 0.151521E+10 | 0.362432E+10 | 0.492034E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.758424E+10 | 0.497973E+10 | 0.136144E+10 | 0.324845E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.845550E+10 | 0.174848E+11 | 0.00 | 0.154069E+11 | 0.581627E+09 | 0.00 | 0.00 | 0.00 |
April | 0.812961E+10 | 0.353747E+11 | 0.00 | 0.534615E+10 | 0.216844E+10 | 0.00 | 0.00 | 0.00 |
May | 0.840767E+10 | 0.637674E+11 | 0.00 | 0.877266E+09 | 0.111353E+11 | 0.00 | 0.00 | 0.00 |
June | 0.821714E+10 | 0.860205E+11 | 0.00 | 0.163136E+09 | 0.288865E+11 | 0.00 | 0.00 | 0.00 |
July | 0.838867E+10 | 0.983115E+11 | 0.00 | 334022.56 | 0.397215E+11 | 0.00 | 0.00 | 0.00 |
August | 0.851955E+10 | 0.103309E+12 | 0.00 | 4965059.75 | 0.433048E+11 | 0.00 | 0.00 | 0.00 |
September | 0.815811E+10 | 0.706488E+11 | 0.00 | 0.441021E+09 | 0.198871E+11 | 0.00 | 0.00 | 0.00 |
October | 0.831812E+10 | 0.334245E+11 | 0.00 | 0.845012E+10 | 0.472165E+10 | 0.00 | 0.00 | 0.00 |
November | 0.800654E+10 | 0.130865E+11 | 0.00 | 0.195252E+11 | 0.301035E+09 | 0.00 | 0.00 | 0.00 |
December | 0.833337E+10 | 0.649158E+10 | 0.330849E+09 | 0.395161E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.989452E+11 | 0.534414E+12 | 0.531661E+10 | 0.171419E+12 | 0.150708E+12 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.758424E+10 | 0.151521E+10 | 0.00 | 334022.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.851955E+10 | 0.103309E+12 | 0.362432E+10 | 0.492034E+11 | 0.433048E+11 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.858330E+09 | 51522900.08 | 0.230991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.758340E+09 | 0.816931E+09 | 0.124193E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.818275E+09 | 0.245334E+10 | 89712376.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.784719E+09 | 0.504264E+10 | 36964416.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.811182E+09 | 0.934655E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.837142E+09 | 0.146402E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.906775E+09 | 0.175198E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.968498E+09 | 0.196384E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.824343E+09 | 0.131085E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.809234E+09 | 0.622673E+10 | 6185416.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.774660E+09 | 0.237931E+10 | 75576883.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.817960E+09 | 0.517292E+09 | 0.598499E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.996946E+10 | 0.917412E+11 | 0.435878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.758340E+09 | 51522900.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.968498E+09 | 0.196384E+11 | 0.230991E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.715336E+09 | 7835039.20 | 0.418012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.617266E+09 | 0.444273E+09 | 0.241350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.637593E+09 | 0.130283E+10 | 0.379867E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.606378E+09 | 0.299591E+10 | 0.111794E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.623986E+09 | 0.618950E+10 | 228357.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.641682E+09 | 0.113148E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.699525E+09 | 0.138910E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.749123E+09 | 0.159321E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.635781E+09 | 0.986121E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.624791E+09 | 0.431966E+10 | 62142106.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.601600E+09 | 0.122405E+10 | 0.265431E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.653856E+09 | 0.226532E+09 | 0.150682E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.780692E+10 | 0.677096E+11 | 0.891990E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.601600E+09 | 7835039.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.749123E+09 | 0.159321E+11 | 0.418012E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:1
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.153024E+10 | 0.00 | 0.00 | 0.00 | 501.24 | 0.00 | 0.104568E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.131277E+10 | 0.00 | 0.00 | 0.00 | 48258614.61 | 0.00 | 0.566714E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.135193E+10 | 0.00 | 0.00 | 0.00 | 0.349796E+09 | 0.00 | 0.412803E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129179E+10 | 0.00 | 0.00 | 0.00 | 0.121516E+10 | 0.00 | 71119608.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.133485E+10 | 0.00 | 0.00 | 0.00 | 0.288212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.132643E+10 | 0.00 | 0.00 | 0.00 | 0.514409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.140755E+10 | 0.00 | 0.00 | 0.00 | 0.612364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.144246E+10 | 0.00 | 0.00 | 0.00 | 0.657309E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.130389E+10 | 0.00 | 0.00 | 0.00 | 0.392878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.132144E+10 | 0.00 | 0.00 | 0.00 | 0.123356E+10 | 0.00 | 14399500.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128206E+10 | 0.00 | 0.00 | 0.00 | 0.172967E+09 | 0.00 | 0.480149E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.139067E+10 | 0.00 | 0.00 | 0.00 | 14297438.71 | 0.00 | 0.342119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.162961E+11 | 0.00 | 0.00 | 0.00 | 0.276858E+11 | 0.00 | 0.205236E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.128206E+10 | 0.00 | 0.00 | 0.00 | 501.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.153024E+10 | 0.00 | 0.00 | 0.00 | 0.657309E+10 | 0.00 | 0.104568E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:2
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.842663E+10 | 0.00 | 0.00 | 0.00 | 0.463397E+09 | 0.00 | 0.453040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.758424E+10 | 0.00 | 0.00 | 0.00 | 0.150036E+10 | 0.00 | 0.170180E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.845550E+10 | 0.00 | 0.00 | 0.00 | 0.511727E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.812961E+10 | 0.00 | 0.00 | 0.00 | 0.102174E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.840767E+10 | 0.00 | 0.00 | 0.00 | 0.181035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.821714E+10 | 0.00 | 0.00 | 0.00 | 0.247795E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.838867E+10 | 0.00 | 0.00 | 0.00 | 0.281444E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.851955E+10 | 0.00 | 0.00 | 0.00 | 0.293068E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.815811E+10 | 0.00 | 0.00 | 0.00 | 0.198735E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.831812E+10 | 0.00 | 0.00 | 0.00 | 0.949745E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.800654E+10 | 0.00 | 0.00 | 0.00 | 0.385709E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.833337E+10 | 0.00 | 0.00 | 0.00 | 0.195854E+10 | 0.00 | 0.413561E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.989452E+11 | 0.00 | 0.00 | 0.00 | 0.152819E+12 | 0.00 | 0.664576E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.758424E+10 | 0.00 | 0.00 | 0.00 | 0.463397E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.851955E+10 | 0.00 | 0.00 | 0.00 | 0.293068E+11 | 0.00 | 0.453040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:3
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.858330E+09 | 0.00 | 0.00 | 0.00 | 13674385.47 | 0.00 | 0.288739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.758340E+09 | 0.00 | 0.00 | 0.00 | 0.206095E+09 | 0.00 | 0.155241E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.818275E+09 | 0.00 | 0.00 | 0.00 | 0.611356E+09 | 0.00 | 0.112140E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.784719E+09 | 0.00 | 0.00 | 0.00 | 0.126496E+10 | 0.00 | 46205520.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.811182E+09 | 0.00 | 0.00 | 0.00 | 0.229716E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.837142E+09 | 0.00 | 0.00 | 0.00 | 0.358242E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.906775E+09 | 0.00 | 0.00 | 0.00 | 0.425994E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.968498E+09 | 0.00 | 0.00 | 0.00 | 0.471156E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.824343E+09 | 0.00 | 0.00 | 0.00 | 0.310251E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.809234E+09 | 0.00 | 0.00 | 0.00 | 0.147136E+10 | 0.00 | 7731770.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.774660E+09 | 0.00 | 0.00 | 0.00 | 0.584529E+09 | 0.00 | 94471104.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.817960E+09 | 0.00 | 0.00 | 0.00 | 0.127031E+09 | 0.00 | 0.748124E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.996946E+10 | 0.00 | 0.00 | 0.00 | 0.222326E+11 | 0.00 | 0.544848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.758340E+09 | 0.00 | 0.00 | 0.00 | 13674385.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.968498E+09 | 0.00 | 0.00 | 0.00 | 0.471156E+10 | 0.00 | 0.288739E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC:4
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.715336E+09 | 0.00 | 0.00 | 0.00 | 2164464.52 | 0.00 | 0.522515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.617266E+09 | 0.00 | 0.00 | 0.00 | 0.114413E+09 | 0.00 | 0.301688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.637593E+09 | 0.00 | 0.00 | 0.00 | 0.332542E+09 | 0.00 | 0.474834E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.606378E+09 | 0.00 | 0.00 | 0.00 | 0.773183E+09 | 0.00 | 0.139742E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.623986E+09 | 0.00 | 0.00 | 0.00 | 0.155176E+10 | 0.00 | 285447.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.641682E+09 | 0.00 | 0.00 | 0.00 | 0.277192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.699525E+09 | 0.00 | 0.00 | 0.00 | 0.336827E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.749123E+09 | 0.00 | 0.00 | 0.00 | 0.380270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.635781E+09 | 0.00 | 0.00 | 0.00 | 0.234506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.624791E+09 | 0.00 | 0.00 | 0.00 | 0.103014E+10 | 0.00 | 77677632.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.601600E+09 | 0.00 | 0.00 | 0.00 | 0.308445E+09 | 0.00 | 0.331789E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.653856E+09 | 0.00 | 0.00 | 0.00 | 56982219.64 | 0.00 | 0.188352E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.780692E+10 | 0.00 | 0.00 | 0.00 | 0.164576E+11 | 0.00 | 0.111499E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.601600E+09 | 0.00 | 0.00 | 0.00 | 2164464.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.749123E+09 | 0.00 | 0.00 | 0.00 | 0.380270E+10 | 0.00 | 0.522515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: BACK_SPACE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.280925E+10 | 0.00 | 0.00 | 14120.09 | 0.00 | 0.495241E+10 | 45214356.08 | 0.00 | 0.20 |
February | 0.278173E+10 | 0.00 | 0.00 | 659781.98 | 47650.57 | 0.258584E+10 | 0.640108E+09 | 0.00 | 0.25 |
March | 0.287392E+10 | 36170406.62 | 0.00 | 3060087.61 | 0.00 | 0.172156E+09 | 0.248247E+10 | 0.00 | 0.33 |
April | 0.106306E+10 | 0.121022E+09 | 0.00 | 5340869.14 | 2181041.00 | 17350706.20 | 0.262700E+10 | 0.00 | 0.42 |
May | 0.194795E+09 | 0.125965E+10 | 0.00 | 6062231.22 | 712503.88 | 0.00 | 0.189624E+10 | 0.00 | 0.39 |
June | 18598711.07 | 0.449701E+10 | 0.00 | 3447831.12 | 8040247.44 | 0.00 | 0.512526E+09 | 0.00 | 0.27 |
July | 3112339.63 | 0.642614E+10 | 0.00 | 1664483.43 | 14249965.94 | 0.00 | 0.229459E+09 | 0.00 | 0.24 |
August | 2425989.60 | 0.722199E+10 | 0.00 | 690403.52 | 20681748.01 | 0.00 | 48007693.78 | 0.00 | 0.22 |
September | 35810344.09 | 0.308330E+10 | 0.00 | 5226687.97 | 11210783.73 | 0.00 | 0.136253E+10 | 0.00 | 0.33 |
October | 0.134726E+10 | 0.593985E+09 | 0.00 | 7271697.21 | 142716.35 | 0.00 | 0.396484E+10 | 0.00 | 0.40 |
November | 0.298030E+10 | 11180155.93 | 0.00 | 3795397.19 | 14748489.47 | 0.188320E+09 | 0.292622E+10 | 0.00 | 0.34 |
December | 0.450325E+10 | 0.00 | 0.00 | 565395.78 | 0.00 | 0.153388E+10 | 0.503870E+09 | 0.00 | 0.22 |
Annual Sum or Average | 0.186135E+11 | 0.232504E+11 | 0.00 | 37798986.28 | 72015146.39 | 0.944996E+10 | 0.172385E+11 | 0.00 | 0.30 |
Minimum of Months | 2425989.60 | 0.00 | 0.00 | 14120.09 | 0.00 | 0.00 | 45214356.08 | 0.00 | 0.20 |
Maximum of Months | 0.450325E+10 | 0.722199E+10 | 0.00 | 7271697.21 | 20681748.01 | 0.495241E+10 | 0.396484E+10 | 0.00 | 0.42 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.177063E+11 | 0.00 | 0.00 | 4916343.12 | 0.00 | 0.268559E+10 | 0.479590E+10 | 0.00 | 0.40 |
February | 0.107034E+11 | 0.00 | 0.00 | 17953677.49 | 0.00 | 0.104031E+10 | 0.116957E+11 | 0.00 | 0.46 |
March | 0.236452E+10 | 0.365043E+09 | 0.00 | 45710650.24 | 3055147.03 | 0.00 | 0.240941E+11 | 0.00 | 0.53 |
April | 0.728043E+09 | 0.129309E+10 | 0.00 | 44379820.26 | 613564.37 | 0.00 | 0.155602E+11 | 0.00 | 0.54 |
May | 71520081.56 | 0.677498E+10 | 0.00 | 28110241.38 | 34973714.93 | 0.00 | 0.528397E+10 | 0.00 | 0.47 |
June | 50756324.40 | 0.164292E+11 | 0.00 | 12717648.50 | 0.152418E+09 | 0.00 | 0.178189E+10 | 0.00 | 0.44 |
July | 4193768.26 | 0.231918E+11 | 0.00 | 703499.11 | 0.237728E+09 | 0.00 | 3369155.46 | 0.00 | 0.40 |
August | 299651.41 | 0.255538E+11 | 0.00 | 416122.34 | 0.253430E+09 | 0.00 | 6944409.17 | 0.00 | 0.41 |
September | 34977429.95 | 0.122697E+11 | 0.00 | 19085617.15 | 0.132669E+09 | 0.00 | 0.430157E+10 | 0.00 | 0.45 |
October | 0.722091E+09 | 0.313030E+10 | 0.00 | 52272932.77 | 11957067.27 | 0.00 | 0.207848E+11 | 0.00 | 0.52 |
November | 0.305999E+10 | 0.271772E+09 | 0.00 | 41496384.11 | 38574541.00 | 0.00 | 0.221521E+11 | 0.00 | 0.50 |
December | 0.100388E+11 | 0.00 | 0.00 | 18283906.19 | 0.00 | 0.226555E+09 | 0.132314E+11 | 0.00 | 0.42 |
Annual Sum or Average | 0.454849E+11 | 0.892797E+11 | 0.00 | 0.286047E+09 | 0.865418E+09 | 0.395245E+10 | 0.123692E+12 | 0.00 | 0.46 |
Minimum of Months | 299651.41 | 0.00 | 0.00 | 416122.34 | 0.00 | 0.00 | 3369155.46 | 0.00 | 0.40 |
Maximum of Months | 0.177063E+11 | 0.255538E+11 | 0.00 | 52272932.77 | 0.253430E+09 | 0.268559E+10 | 0.240941E+11 | 0.00 | 0.54 |
Report: MechanicalVentilationLoadsMonthly
For: POINT_OF_SALE
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.387947E+10 | 0.00 | 0.00 | 1554545.86 | 0.00 | 0.995263E+09 | 0.127503E+10 | 0.00 | 0.44 |
February | 0.263626E+10 | 77728.74 | 0.00 | 3973500.81 | 0.00 | 0.484822E+09 | 0.183713E+10 | 0.00 | 0.58 |
March | 0.103749E+10 | 0.102341E+09 | 0.00 | 7839655.59 | 0.00 | 15552326.46 | 0.365847E+10 | 0.00 | 0.74 |
April | 0.469859E+09 | 0.347787E+09 | 0.00 | 5579489.99 | 0.00 | 760823.75 | 0.205261E+10 | 0.00 | 0.68 |
May | 0.112429E+09 | 0.147677E+10 | 0.00 | 4300748.90 | 886048.99 | 0.00 | 0.956909E+09 | 0.00 | 0.61 |
June | 13315383.58 | 0.388534E+10 | 0.00 | 1835887.77 | 3178535.51 | 0.00 | 0.255072E+09 | 0.00 | 0.48 |
July | 582374.41 | 0.543410E+10 | 0.00 | 519540.49 | 7677880.81 | 0.00 | 62159049.14 | 0.00 | 0.42 |
August | 118111.17 | 0.614650E+10 | 0.00 | 275062.83 | 7616098.43 | 0.00 | 26646193.72 | 0.00 | 0.41 |
September | 19105018.40 | 0.294428E+10 | 0.00 | 3191553.48 | 3582532.65 | 0.00 | 0.652126E+09 | 0.00 | 0.53 |
October | 0.514640E+09 | 0.756790E+09 | 0.00 | 10278938.73 | 36628.52 | 0.00 | 0.324478E+10 | 0.00 | 0.75 |
November | 0.107978E+10 | 78409919.98 | 0.00 | 9153433.49 | 877311.19 | 24930283.57 | 0.391441E+10 | 0.00 | 0.73 |
December | 0.253412E+10 | 5120299.70 | 0.00 | 4537729.95 | 0.00 | 0.194176E+09 | 0.300119E+10 | 0.00 | 0.54 |
Annual Sum or Average | 0.122972E+11 | 0.211775E+11 | 0.00 | 53040087.87 | 23855036.11 | 0.171550E+10 | 0.209365E+11 | 0.00 | 0.58 |
Minimum of Months | 118111.17 | 0.00 | 0.00 | 275062.83 | 0.00 | 0.00 | 26646193.72 | 0.00 | 0.41 |
Maximum of Months | 0.387947E+10 | 0.614650E+10 | 0.00 | 10278938.73 | 7677880.81 | 0.995263E+09 | 0.391441E+10 | 0.00 | 0.75 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_RETAIL
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.318414E+10 | 0.00 | 0.00 | 216802.07 | 0.00 | 0.227205E+10 | 0.228043E+09 | 0.00 | 0.40 |
February | 0.245941E+10 | 0.00 | 0.00 | 1536321.98 | 0.00 | 0.117669E+10 | 0.678095E+09 | 0.00 | 0.47 |
March | 0.178784E+10 | 71016339.94 | 0.00 | 2950635.57 | 0.00 | 0.126676E+09 | 0.161783E+10 | 0.00 | 0.55 |
April | 0.867638E+09 | 0.218207E+09 | 0.00 | 2133528.92 | 812062.65 | 55454759.74 | 0.953972E+09 | 0.00 | 0.54 |
May | 0.237816E+09 | 0.115888E+10 | 0.00 | 2063509.68 | 620695.52 | 0.00 | 0.644171E+09 | 0.00 | 0.53 |
June | 45397283.90 | 0.354911E+10 | 0.00 | 1116935.11 | 9500526.16 | 0.00 | 0.159451E+09 | 0.00 | 0.45 |
July | 3820968.29 | 0.497595E+10 | 0.00 | 563478.29 | 15747849.27 | 0.00 | 95036488.22 | 0.00 | 0.42 |
August | 1212135.11 | 0.573820E+10 | 0.00 | 278243.37 | 7613739.17 | 0.00 | 22065359.12 | 0.00 | 0.41 |
September | 91847388.01 | 0.261530E+10 | 0.00 | 1838028.11 | 8550258.98 | 0.00 | 0.473837E+09 | 0.00 | 0.48 |
October | 0.110149E+10 | 0.630415E+09 | 0.00 | 5360214.76 | 182793.98 | 14175361.47 | 0.171958E+10 | 0.00 | 0.58 |
November | 0.184114E+10 | 26864838.46 | 0.00 | 4125980.86 | 2632084.17 | 95490465.72 | 0.195043E+10 | 0.00 | 0.56 |
December | 0.323293E+10 | 832444.87 | 0.00 | 1318641.81 | 0.00 | 0.645853E+09 | 0.877737E+09 | 0.00 | 0.44 |
Annual Sum or Average | 0.148547E+11 | 0.189848E+11 | 0.00 | 23502320.53 | 45660009.90 | 0.438639E+10 | 0.942024E+10 | 0.00 | 0.49 |
Minimum of Months | 1212135.11 | 0.00 | 0.00 | 216802.07 | 0.00 | 0.00 | 22065359.12 | 0.00 | 0.40 |
Maximum of Months | 0.323293E+10 | 0.573820E+10 | 0.00 | 5360214.76 | 15747849.27 | 0.227205E+10 | 0.195043E+10 | 0.00 | 0.58 |
Report: MechanicalVentilationLoadsMonthly
For: FRONT_ENTRY
Timestamp: 2020-06-03 19:13:29
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |