Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:19
Tabular Output Report in Format: HTML
Building: RetailStripmall
Environment: RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885
Simulation Timestamp: 2020-06-03 19:19:03
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1370.01 | 655.41 | 655.41 |
Net Site Energy | 1370.01 | 655.41 | 655.41 |
Total Source Energy | 3788.92 | 1812.60 | 1812.60 |
Net Source Energy | 3788.92 | 1812.60 | 1812.60 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 2090.32 |
Net Conditioned Building Area | 2090.32 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 263.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 13.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 587.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 110.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 201.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 65.13 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1106.02 | 263.99 | 0.00 | 0.00 | 0.00 | 87.30 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 263.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 13.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 587.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 110.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 128.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 201.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 65.13 | 0.00 | 0.00 | 0.00 | 0.00 | 87.30 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 333.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 133.81 | 126.29 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 529.11 | 126.29 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 333.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 133.81 | 126.29 | 0.00 | 0.00 | 0.00 | 0.04 |
Other | 61.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 529.11 | 126.29 | 0.00 | 0.00 | 0.00 | 0.04 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1106.016 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1106.016 | 100.00 |
Total On-Site and Utility Electric Sources | 1106.016 | 100.00 |
Total Electricity End Uses | 1106.016 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 87.30 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 87.30 | 100.00 |
Total Water End Uses | 87.30 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 0.00 |
Time Setpoint Not Met During Occupied Cooling | 0.00 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 960.67 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
| Meter |ZoneCoolingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneHeatingSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ZoneElectricSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |PeakSpaceGainsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |SpaceGainComponentsAtCoolingPeakMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |ComfortReportSimple55Monthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |OccupantComfortDataSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |DXReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |WindowReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowEnergyReportMonthly
| LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR |WindowZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |WindowEnergyZoneSummaryMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| GAS TANK1 | GAS TANK2 | GAS TANK3 | GAS TANK4 | GAS TANK5 | GAS TANK6 | GAS TANK7 |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL |FanReportMonthly
| PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN |ZoneTemperatureOscillationReportMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentLoadsMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |AirLoopSystemComponentEnergyUseMonthly
| PSZ-AC_1:1 | PSZ-AC_2:2 | PSZ-AC_3:3 | PSZ-AC_4:4 | PSZ-AC_5:5 | PSZ-AC_6:6 | PSZ-AC_7:7 | PSZ-AC_8:8 | PSZ-AC_9:9 | PSZ-AC_10:10 |MechanicalVentilationLoadsMonthly
| LGSTORE1 | SMSTORE1 | SMSTORE2 | SMSTORE3 | SMSTORE4 | LGSTORE2 | SMSTORE5 | SMSTORE6 | SMSTORE7 | SMSTORE8 |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:19 |
RunPeriod | RUNPERIOD 1 |
Weather File | William R Fairchild WA USA TMY3 WMO#=727885 |
Latitude [deg] | 48.12 |
Longitude [deg] | -123.5 |
Elevation [m] | 91.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Above Ground Wall Area [m2] | 1184.15 | 473.66 | 118.41 | 473.66 | 118.41 |
Window Opening Area [m2] | 124.29 | 0.00 | 0.00 | 124.29 | 0.00 |
Gross Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Above Ground Window-Wall Ratio [%] | 10.50 | 0.00 | 0.00 | 26.24 | 0.00 |
Total | |
Gross Roof Area [m2] | 2090.32 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
LGSTORE1 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 276.30 | 0.00 | 20.75 | 20.75 | 21.0784 | 11.61 | 4.3000 |
SMSTORE1 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.37 | 10.37 | 22.5208 | 11.61 | 4.3000 |
SMSTORE2 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 20.3680 | 11.61 | 4.3000 |
SMSTORE3 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 20.3680 | 11.61 | 4.3000 |
SMSTORE4 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 20.3680 | 11.61 | 4.3000 |
LGSTORE2 | 348.39 | Yes | Yes | 1805.20 | 1.00 | 157.89 | 0.00 | 20.70 | 20.70 | 15.8795 | 11.61 | 4.3000 |
SMSTORE5 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 15.8795 | 11.61 | 4.3000 |
SMSTORE6 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 15.8795 | 11.61 | 4.3000 |
SMSTORE7 | 174.19 | Yes | Yes | 902.60 | 1.00 | 78.94 | 0.00 | 10.35 | 10.35 | 15.8795 | 11.61 | 4.3000 |
SMSTORE8 | 174.19 | Yes | Yes | 902.60 | 1.00 | 197.36 | 0.00 | 10.35 | 10.35 | 15.8795 | 11.61 | 4.3000 |
Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 18.4215 | 11.61 | 4.3000 | |||
Conditioned Total | 2090.32 | 10831.20 | 1184.15 | 0.00 | 124.29 | 124.29 | 18.4215 | 11.61 | 4.3000 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 22-JUL-15:50 | 10-JAN-09:09 | - | - | - | 06-JAN-13:09 |
Heating | 0.00 | 149961.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 26676.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 36581.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 5448.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 88480.21 | 149961.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 149961.26 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 26676.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 36581.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 5448.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 286.17 | 0.00 | 0.00 | 0.00 |
Cooling | 41.84 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1859.24 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 350.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 407.66 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 637.69 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 206.28 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 3502.75 | 286.17 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 136.90 | 0.00 | 0.00 | 0.00 |
Cooling | 20.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 889.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 167.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 305.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 98.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1675.70 | 136.90 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 136.90 | 0.00 | 0.00 | 0.00 |
Cooling | 20.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 889.45 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 167.46 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 195.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 305.07 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 98.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 1675.70 | 136.90 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
LGSTORE1 DIRECT AIR | 1.70 |
SMSTORE1 DIRECT AIR | 0.933897 |
SMSTORE2 DIRECT AIR | 0.927465 |
SMSTORE3 DIRECT AIR | 0.921226 |
SMSTORE4 DIRECT AIR | 0.926288 |
LGSTORE2 DIRECT AIR | 1.66 |
SMSTORE5 DIRECT AIR | 0.898647 |
SMSTORE6 DIRECT AIR | 0.890789 |
SMSTORE7 DIRECT AIR | 0.876364 |
SMSTORE8 DIRECT AIR | 0.869634 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-AC_1:1 | 1.70 | 1.70 | 1.70 | 1.70 | 1.70 | 1.70 | 1.00 | 1.00 | 1.70 |
PSZ-AC_2:2 | 0.933897 | 0.933897 | 0.933897 | 0.933897 | 0.939928 | 0.939928 | 1.00 | 0.993583 | 0.939928 |
PSZ-AC_3:3 | 0.927465 | 0.927465 | 0.927465 | 0.927465 | 0.927465 | 0.927465 | 1.00 | 1.000000 | 0.927465 |
PSZ-AC_4:4 | 0.921226 | 0.921226 | 0.921226 | 0.921226 | 0.923365 | 0.923365 | 1.00 | 0.997683 | 0.923365 |
PSZ-AC_5:5 | 0.926288 | 0.926288 | 0.926288 | 0.926288 | 0.926288 | 0.926288 | 1.00 | 1.000000 | 0.926288 |
PSZ-AC_6:6 | 1.66 | 1.66 | 1.66 | 1.66 | 1.69 | 1.69 | 1.00 | 0.981607 | 1.69 |
PSZ-AC_7:7 | 0.898647 | 0.898647 | 0.898647 | 0.898647 | 0.901380 | 0.901380 | 1.00 | 0.996968 | 0.901380 |
PSZ-AC_8:8 | 0.890789 | 0.890789 | 0.890789 | 0.890789 | 0.894206 | 0.894206 | 1.00 | 0.996179 | 0.894206 |
PSZ-AC_9:9 | 0.876364 | 0.876364 | 0.876364 | 0.876364 | 0.881643 | 0.881643 | 1.00 | 0.994012 | 0.881643 |
PSZ-AC_10:10 | 0.869634 | 0.869634 | 0.869634 | 0.869634 | 0.883304 | 0.883304 | 1.00 | 0.984524 | 0.883304 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-AC_1:1_OA_CONTROLLER | 1.70 | 0.411453 |
PSZ-AC_2:2_OA_CONTROLLER | 0.939928 | 0.205727 |
PSZ-AC_3:3_OA_CONTROLLER | 0.927465 | 0.205727 |
PSZ-AC_4:4_OA_CONTROLLER | 0.923365 | 0.205727 |
PSZ-AC_5:5_OA_CONTROLLER | 0.926288 | 0.205727 |
PSZ-AC_6:6_OA_CONTROLLER | 1.69 | 0.411453 |
PSZ-AC_7:7_OA_CONTROLLER | 0.901380 | 0.205727 |
PSZ-AC_8:8_OA_CONTROLLER | 0.894206 | 0.205727 |
PSZ-AC_9:9_OA_CONTROLLER | 0.881643 | 0.205727 |
PSZ-AC_10:10_OA_CONTROLLER | 0.883304 | 0.205727 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-AC_1:1_UNITARY_PACKAGE_DX | 1.70 | 1.70 | 1.70 | 1.70 | 28119.71 | 50934.82 | 40.00 | 1.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_DX | 0.939928 | 0.939928 | 0.939928 | 0.939928 | 15559.14 | 27379.57 | 40.00 | 1.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_DX | 0.927465 | 0.927465 | 0.927465 | 0.927465 | 15352.84 | 27234.12 | 40.00 | 1.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_DX | 0.923365 | 0.923365 | 0.923365 | 0.923365 | 15284.97 | 27093.01 | 40.00 | 1.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_DX | 0.926288 | 0.926288 | 0.926288 | 0.926288 | 15333.36 | 27207.50 | 40.00 | 1.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_DX | 1.69 | 1.69 | 1.69 | 1.69 | 27991.62 | 50056.32 | 40.00 | 1.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_DX | 0.901380 | 0.901380 | 0.901380 | 0.901380 | 14921.05 | 26582.35 | 40.00 | 1.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_DX | 0.894206 | 0.894206 | 0.894206 | 0.894206 | 14802.29 | 26404.62 | 40.00 | 1.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_DX | 0.881643 | 0.881643 | 0.881643 | 0.881643 | 14594.33 | 26078.35 | 40.00 | 1.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_DX | 0.883304 | 0.883304 | 0.883304 | 0.883304 | 14621.82 | 25926.23 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 1.70 | 0.849355 | 1.70 | 28119.68 | 28119.71 | 14059.85 | 28119.71 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 0.939930 | 0.469965 | 0.939930 | 15559.18 | 15559.14 | 7779.57 | 15559.14 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 0.927470 | 0.463735 | 0.927470 | 15352.92 | 15352.84 | 7676.42 | 15352.84 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 0.923370 | 0.461685 | 0.923370 | 15285.05 | 15284.97 | 7642.48 | 15284.97 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 0.926290 | 0.463145 | 0.926290 | 15333.39 | 15333.36 | 7666.68 | 15333.36 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 1.69 | 0.845485 | 1.69 | 27991.56 | 27991.62 | 13995.81 | 27991.62 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 0.901380 | 0.450690 | 0.901380 | 14921.04 | 14921.05 | 7460.52 | 14921.05 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 0.894210 | 0.447105 | 0.894210 | 14802.35 | 14802.29 | 7401.15 | 14802.29 | 0.798655 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 0.881640 | 0.440820 | 0.881640 | 14594.27 | 14594.33 | 7297.16 | 14594.33 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 0.883300 | 0.441650 | 0.883300 | 14621.75 | 14621.82 | 7310.91 | 14621.82 | 0.798654 | 0.798660 | 0.798660 | 0.798660 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | 1.70 | 1817.70 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | 0.939928 | 1040.65 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | 0.927465 | 1026.85 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | 0.923365 | 1022.31 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | 0.926288 | 1025.55 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | 1.69 | 1809.42 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | 0.901380 | 997.97 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | 0.894206 | 990.03 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | 0.881643 | 976.12 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | 0.883304 | 977.96 |
Design Size Nominal Capacity [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | 50934.82 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | 27379.57 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | 27234.12 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | 27093.01 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | 27207.50 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | 50056.32 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | 26582.35 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | 26404.62 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | 26078.35 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | 25926.23 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
LGSTORE1_WALL_3 | LGSTORE1_WALL_3_DOOR_1 | LGSTORE1_WALL_3_DOOR_2 | |
LGSTORE1_WALL_1 | LGSTORE1_WALL_1_WINDOW_1 | LGSTORE1_WALL_1_WINDOW_2 | LGSTORE1_WALL_1_WINDOW_3 | LGSTORE1_WALL_1_WINDOW_4 | LGSTORE1_WALL_1_DOOR_1 | LGSTORE1_WALL_1_DOOR_2 | |
SMSTORE1_WALL_1 | SMSTORE1_WALL_1_WINDOW_1 | SMSTORE1_WALL_1_WINDOW_2 | SMSTORE1_WALL_1_DOOR | |
SMSTORE1_WALL_3 | SMSTORE1_WALL_3_DOOR | |
SMSTORE2_WALL_1 | SMSTORE2_WALL_1_WINDOW_1 | SMSTORE2_WALL_1_WINDOW_2 | SMSTORE2_WALL_1_DOOR | |
SMSTORE2_WALL_3 | SMSTORE2_WALL_3_DOOR | |
SMSTORE3_WALL_1 | SMSTORE3_WALL_1_WINDOW_1 | SMSTORE3_WALL_1_WINDOW_2 | SMSTORE3_WALL_1_DOOR | |
SMSTORE3_WALL_3 | SMSTORE3_WALL_3_DOOR | |
SMSTORE4_WALL_1 | SMSTORE4_WALL_1_WINDOW_1 | SMSTORE4_WALL_1_WINDOW_2 | SMSTORE4_WALL_1_DOOR | |
SMSTORE4_WALL_3 | SMSTORE4_WALL_3_DOOR | |
LGSTORE2_WALL_3 | LGSTORE2_WALL_3_DOOR_1 | LGSTORE2_WALL_3_DOOR_2 | |
LGSTORE2_WALL_1 | LGSTORE2_WALL_1_WINDOW_1 | LGSTORE2_WALL_1_WINDOW_2 | LGSTORE2_WALL_1_WINDOW_3 | LGSTORE2_WALL_1_WINDOW_4 | LGSTORE2_WALL_1_DOOR_1 | LGSTORE2_WALL_1_DOOR_2 | |
SMSTORE5_WALL_1 | SMSTORE5_WALL_1_WINDOW_1 | SMSTORE5_WALL_1_WINDOW_2 | SMSTORE5_WALL_1_DOOR | |
SMSTORE5_WALL_3 | SMSTORE5_WALL_3_DOOR | |
SMSTORE6_WALL_1 | SMSTORE6_WALL_1_WINDOW_1 | SMSTORE6_WALL_1_WINDOW_2 | SMSTORE6_WALL_1_DOOR | |
SMSTORE6_WALL_3 | SMSTORE6_WALL_3_DOOR | |
SMSTORE7_WALL_1 | SMSTORE7_WALL_1_WINDOW_1 | SMSTORE7_WALL_1_WINDOW_2 | SMSTORE7_WALL_1_DOOR | |
SMSTORE7_WALL_3 | SMSTORE7_WALL_3_DOOR | |
SMSTORE8_WALL_1 | SMSTORE8_WALL_1_WINDOW_1 | SMSTORE8_WALL_1_WINDOW_2 | SMSTORE8_WALL_1_DOOR | |
SMSTORE8_WALL_3 | SMSTORE8_WALL_3_DOOR | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 9.30 | 6.70 | 4.10 | 4.20 | 4.20 | 5.90 | 9.00 | 10.00 | 13.30 | 15.00 | 15.70 | 13.40 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | William R Fairchild WA USA TMY3 WMO#=727885 | 48.12 | -123.50 | -8.00 | 91.00 | 100237 | 1.1914 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.23 | 11.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | RetailStripmall | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 10 | 118 | 48 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | LGSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 7.62 | 11.43 | 2.59 | 1 | 1 | 1 | 0.00 | 15.24 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 276.30 | 247.76 | 20.75 | 6 | 8 | 0 | Yes |
2 | SMSTORE1 | 0.0 | 0.00 | 0.00 | 0.00 | 19.05 | 11.43 | 2.59 | 1 | 1 | 1 | 15.24 | 22.86 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.67 | 10.37 | 6 | 4 | 0 | Yes |
3 | SMSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 26.67 | 11.43 | 2.59 | 1 | 1 | 1 | 22.86 | 30.48 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
4 | SMSTORE3 | 0.0 | 0.00 | 0.00 | 0.00 | 34.29 | 11.43 | 2.59 | 1 | 1 | 1 | 30.48 | 38.10 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
5 | SMSTORE4 | 0.0 | 0.00 | 0.00 | 0.00 | 41.91 | 11.43 | 2.59 | 1 | 1 | 1 | 38.10 | 45.72 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
6 | LGSTORE2 | 0.0 | 0.00 | 0.00 | 0.00 | 53.34 | 11.43 | 2.59 | 1 | 1 | 1 | 45.72 | 60.96 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 1805.20 | TARP | TARP | 348.39 | 157.89 | 129.43 | 20.70 | 6 | 8 | 0 | Yes |
7 | SMSTORE5 | 0.0 | 0.00 | 0.00 | 0.00 | 64.77 | 11.43 | 2.59 | 1 | 1 | 1 | 60.96 | 68.58 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
8 | SMSTORE6 | 0.0 | 0.00 | 0.00 | 0.00 | 72.39 | 11.43 | 2.59 | 1 | 1 | 1 | 68.58 | 76.20 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
9 | SMSTORE7 | 0.0 | 0.00 | 0.00 | 0.00 | 80.01 | 11.43 | 2.59 | 1 | 1 | 1 | 76.20 | 83.82 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 78.94 | 64.71 | 10.35 | 6 | 4 | 0 | Yes |
10 | SMSTORE8 | 0.0 | 0.00 | 0.00 | 0.00 | 87.63 | 11.43 | 2.59 | 1 | 1 | 1 | 83.82 | 91.44 | 0.00 | 22.86 | 0.00 | 5.18 | 5.18 | 902.60 | TARP | TARP | 174.19 | 197.36 | 183.13 | 10.35 | 6 | 4 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | LGSTORE1 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 21.078 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 25.378 | No |
2 | SMSTORE1 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 22.521 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 26.821 | No |
3 | SMSTORE2 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 20.368 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 24.668 | No |
4 | SMSTORE3 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 20.368 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 24.668 | No |
5 | SMSTORE4 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 20.368 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 24.668 | No |
6 | LGSTORE2 | 348.39 | 30.0 | 11.614 | 8.610E-002 | 15.879 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.179 | No |
7 | SMSTORE5 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 15.879 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.179 | No |
8 | SMSTORE6 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 15.879 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.179 | No |
9 | SMSTORE7 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 15.879 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.179 | No |
10 | SMSTORE8 | 174.19 | 15.0 | 11.614 | 8.610E-002 | 15.879 | 4.300 | 0.000 | 0.000 | 0.000 | 0.000 | 20.179 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | |
1 | LGSTORE1 | TYPE1_OCC_SCH | LGSTORE1 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
2 | SMSTORE1 | TYPE1_OCC_SCH | SMSTORE1 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
3 | SMSTORE2 | TYPE2_OCC_SCH | SMSTORE2 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
4 | SMSTORE3 | TYPE2_OCC_SCH | SMSTORE3 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
5 | SMSTORE4 | TYPE2_OCC_SCH | SMSTORE4 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
6 | LGSTORE2 | TYPE3_OCC_SCH | LGSTORE2 | 348.39 | 30.0 | 30.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 30 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
7 | SMSTORE5 | TYPE3_OCC_SCH | SMSTORE5 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
8 | SMSTORE6 | TYPE3_OCC_SCH | SMSTORE6 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
9 | SMSTORE7 | TYPE3_OCC_SCH | SMSTORE7 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
10 | SMSTORE8 | TYPE3_OCC_SCH | SMSTORE8 | 174.19 | 15.0 | 15.0 | 8.610E-002 | 11.614 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 15 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | LGSTORE1_LIGHTS | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 5532.190 | 15.879 | 184.430 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5532.190 |
2 | LGSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | LGSTORE1 | 348.39 | 30.0 | 1811.251 | 5.199 | 60.383 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1811.251 |
3 | SMSTORE1_LIGHTS | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
4 | SMSTORE1_LIGHTS_ALLOWANCE | TYPE1_LIGHT_SCH | SMSTORE1 | 174.19 | 15.0 | 1156.875 | 6.641 | 77.135 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1156.875 |
5 | SMSTORE2_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
6 | SMSTORE2_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE2 | 174.19 | 15.0 | 781.875 | 4.489 | 52.132 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 781.875 |
7 | SMSTORE3_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
8 | SMSTORE3_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE3 | 174.19 | 15.0 | 781.875 | 4.489 | 52.132 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 781.875 |
9 | SMSTORE4_LIGHTS | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
10 | SMSTORE4_LIGHTS_ALLOWANCE | TYPE2_LIGHT_SCH | SMSTORE4 | 174.19 | 15.0 | 781.875 | 4.489 | 52.132 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 781.875 |
11 | LGSTORE2_LIGHTS | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 5532.190 | 15.879 | 184.430 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 5532.190 |
12 | LGSTORE2_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | LGSTORE2 | 348.39 | 30.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
13 | SMSTORE5_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
14 | SMSTORE5_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE5 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
15 | SMSTORE6_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
16 | SMSTORE6_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE6 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
17 | SMSTORE7_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
18 | SMSTORE7_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE7 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
19 | SMSTORE8_LIGHTS | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 2766.095 | 15.879 | 184.431 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 2766.095 |
20 | SMSTORE8_LIGHTS_ALLOWANCE | TYPE3_LIGHT_SCH | SMSTORE8 | 174.19 | 15.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | LGSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | LGSTORE1 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
2 | SMSTORE1_MISCPLUG_EQUIP | TYPE1_EQUIP_SCH | SMSTORE1 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
3 | SMSTORE2_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE2 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
4 | SMSTORE3_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE3 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
5 | SMSTORE4_MISCPLUG_EQUIP | TYPE2_EQUIP_SCH | SMSTORE4 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
6 | LGSTORE2_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | LGSTORE2 | 348.39 | 30.0 | 1498.062 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1498.062 |
7 | SMSTORE5_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE5 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
8 | SMSTORE6_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE6 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
9 | SMSTORE7_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE7 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
10 | SMSTORE8_MISCPLUG_EQUIP | TYPE3_EQUIP_SCH | SMSTORE8 | 174.19 | 15.0 | 749.031 | 4.300 | 49.942 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 749.031 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.2284 | 0.900 | 0.900 | 0.770 | 0.700 | Rough |
5 | NONRES_EXT_WALL | 20 | 4 | 7 | 0.167 | 0.3843 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
6 | LGSTORE1_FLOOR_FFACTOR | 30 | 2 | 7 | 0.167 | 0.1464 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
7 | SMSTORE1_FLOOR_FFACTOR | 31 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
8 | SMSTORE2_FLOOR_FFACTOR | 32 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
9 | SMSTORE3_FLOOR_FFACTOR | 33 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
10 | SMSTORE4_FLOOR_FFACTOR | 34 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
11 | LGSTORE2_FLOOR_FFACTOR | 35 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | SMSTORE5_FLOOR_FFACTOR | 36 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | SMSTORE6_FLOOR_FFACTOR | 37 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | SMSTORE7_FLOOR_FFACTOR | 38 | 2 | 7 | 0.167 | 0.8283E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | SMSTORE8_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2111 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
6 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 4.319 |
7 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
8 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
9 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
10 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.368 |
11 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
12 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 6.756 |
13 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
14 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
15 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
16 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
17 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
18 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
19 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
20 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
21 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
22 | ~FC_Insulation_6 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
23 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
24 | ~FC_Insulation_7 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
25 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
26 | ~FC_Insulation_8 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
27 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
28 | ~FC_Insulation_9 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.00 |
29 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
30 | ~FC_Insulation_10 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.659 |
31 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1009596 | 2.1009596 | 2.1009596 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
14 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
15 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
16 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
17 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
18 | 3 | -0.62451068E-06 | 0.10350887E-08 | -0.38276125E-05 | 0.11995084E-16 |
19 | 2 | 0.77976586 | 0.13989883E-02 | 1.0579789 | -0.73382352E-06 |
20 | 1 | -21.958702 | 0.93426804E-01 | -6.3215779 | 0.20283230 |
21 | 0 | 21.361010 | 0.87247630E-01 | 5.4456762 | |
22 | 7 | -0.35963630E-12 | 0.61482467E-15 | -0.13288964E-12 | 0.15093609E-15 |
23 | 6 | 0.33258387E-07 | 0.11249777E-09 | 0.75805110E-08 | -0.16019892E-12 |
24 | 5 | -0.21313350E-03 | 0.93714421E-06 | -0.10927814E-03 | 0.74776115E-08 |
25 | 4 | 0.31870195 | 0.44521373E-03 | 0.10925225 | -0.37358013E-04 |
26 | 3 | -7.7913368 | 0.13499397E-01 | -2.4947666 | 0.31584435E-01 |
27 | 2 | 42.601618 | 0.47079245E-01 | 15.902165 | -0.35261900 |
28 | 1 | -81.870774 | 0.20888078E-01 | -29.712230 | 1.1068570 |
29 | 0 | 46.824331 | 0.41326549E-03 | 16.278015 | |
30 | 7 | -0.28997596E-08 | -0.17578320E-14 | 0.22751757E-14 | -0.53829073E-16 |
31 | 6 | 0.41991781E-05 | 0.27986603E-08 | 0.31940183E-02 | -0.26794102E-04 |
32 | 5 | -0.29588474E-03 | 0.16552611E-05 | -0.22396035 | 0.19582313E-02 |
33 | 4 | 0.67666006E-02 | 0.75295852E-04 | 4.8334724 | -0.45302727E-01 |
34 | 3 | -0.59297736E-01 | 0.59838054E-03 | -38.043598 | 0.39889893 |
35 | 2 | 0.21038411 | 0.99492606E-03 | 116.52712 | -1.4185167 |
36 | 1 | -0.30354941 | 0.30287292E-03 | -143.93272 | 2.0494576 |
37 | 0 | 0.14796861 | 0.73483799E-05 | 60.838472 | |
38 | 7 | -0.51571905E-08 | -0.97500959E-14 | 0.15789915E-14 | -0.32998988E-16 |
39 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
40 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
41 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
42 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
43 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
44 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
45 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
46 | 7 | -0.51571905E-08 | -0.97500958E-14 | 0.15789913E-14 | -0.32998984E-16 |
47 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
48 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
49 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
50 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
51 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
52 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
53 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
54 | 7 | -0.51571905E-08 | -0.97500959E-14 | 0.15789911E-14 | -0.32998980E-16 |
55 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
56 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
57 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
58 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
59 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
60 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
61 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
62 | 7 | -0.51571905E-08 | -0.97500959E-14 | 0.15789915E-14 | -0.32998988E-16 |
63 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
64 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
65 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
66 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
67 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
68 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
69 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
70 | 7 | -0.51571905E-08 | -0.97500958E-14 | 0.15789913E-14 | -0.32998984E-16 |
71 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
72 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
73 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
74 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
75 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
76 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
77 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
78 | 7 | -0.51571905E-08 | -0.97500957E-14 | 0.15789917E-14 | -0.32998991E-16 |
79 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
80 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
81 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
82 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
83 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
84 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
85 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
86 | 7 | -0.51571905E-08 | -0.97500959E-14 | 0.15789915E-14 | -0.32998988E-16 |
87 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
88 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
89 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
90 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
91 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
92 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
93 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
94 | 7 | -0.51571905E-08 | -0.97500958E-14 | 0.15789913E-14 | -0.32998984E-16 |
95 | 6 | 0.26247599E-05 | 0.15902949E-08 | 0.31989528E-02 | -0.26835497E-04 |
96 | 5 | -0.17282397E-03 | 0.93714128E-06 | -0.22424071 | 0.19607060E-02 |
97 | 4 | 0.38696203E-02 | 0.42548205E-04 | 4.8381400 | -0.45347597E-01 |
98 | 3 | -0.33643188E-01 | 0.33758390E-03 | -38.069955 | 0.39919029 |
99 | 2 | 0.11898200 | 0.56044665E-03 | 116.57840 | -1.4192028 |
100 | 1 | -0.17142224 | 0.17027190E-03 | -143.96290 | 2.0499538 |
101 | 0 | 0.83499932E-01 | 0.41268798E-05 | 60.838472 | |
102 | 7 | -0.19967951E-08 | -0.58252365E-15 | 0.72897552E-14 | -0.10630581E-15 |
103 | 6 | 0.59274927E-05 | 0.40433693E-08 | 0.31889525E-02 | -0.26751606E-04 |
104 | 5 | -0.42514865E-03 | 0.23948505E-05 | -0.22367243 | 0.19556901E-02 |
105 | 4 | 0.97725356E-02 | 0.10900143E-03 | 4.8286774 | -0.45256634E-01 |
106 | 3 | -0.85796444E-01 | 0.86675557E-03 | -38.016512 | 0.39859954 |
107 | 2 | 0.30461848 | 0.14417950E-02 | 116.47440 | -1.4178116 |
108 | 1 | -0.43965446 | 0.43929230E-03 | -143.90169 | 2.0489476 |
109 | 0 | 0.21434897 | 0.10616597E-04 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 29 | 1 | VerySmooth | 2.159 | 0.394 | 0.315 | 0.401 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 3.45900E-002 | 0.31435 | 0.47939 | 0.47939 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 0.11893 | 1.00000 | No |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 30 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | GAS TANK1 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
2 | WaterHeater:Mixed | GAS TANK2 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
3 | WaterHeater:Mixed | GAS TANK3 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
4 | WaterHeater:Mixed | GAS TANK4 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
5 | WaterHeater:Mixed | GAS TANK5 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
6 | WaterHeater:Mixed | GAS TANK6 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
7 | WaterHeater:Mixed | GAS TANK7 | 0.1514 | 11722.8 | 1.020 | 0.7241 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | LGSTORE1_WALL_2 | 0 | 118.41 | 56.08 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
2 | LGSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
3 | LGSTORE1_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
4 | LGSTORE1_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
5 | LGSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
6 | LGSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 4 | No | No |
7 | LGSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
8 | LGSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
9 | LGSTORE1_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
10 | LGSTORE1_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
11 | LGSTORE1_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
12 | LGSTORE1_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 1 | No | No |
13 | LGSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
14 | LGSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
15 | LGSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 53.34 | 18.29 | 7.51E-002 | 0 | No | No |
16 | SMSTORE1_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
17 | SMSTORE1_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
18 | SMSTORE1_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
19 | SMSTORE1_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
20 | SMSTORE1_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
21 | SMSTORE1_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
22 | SMSTORE1_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
23 | SMSTORE1_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
24 | SMSTORE1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
25 | SMSTORE1_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
26 | SMSTORE1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
27 | SMSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
28 | SMSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
29 | SMSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
30 | SMSTORE2_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
31 | SMSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
32 | SMSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
33 | SMSTORE2_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
34 | SMSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
35 | SMSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
36 | SMSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
37 | SMSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
38 | SMSTORE3_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
39 | SMSTORE3_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
40 | SMSTORE3_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
41 | SMSTORE3_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
42 | SMSTORE3_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
43 | SMSTORE3_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
44 | SMSTORE3_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
45 | SMSTORE3_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
46 | SMSTORE3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
47 | SMSTORE3_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
48 | SMSTORE3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
49 | SMSTORE4_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
50 | SMSTORE4_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
51 | SMSTORE4_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
52 | SMSTORE4_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
53 | SMSTORE4_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
54 | SMSTORE4_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
55 | SMSTORE4_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
56 | SMSTORE4_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
57 | SMSTORE4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
58 | SMSTORE4_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
59 | SMSTORE4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
60 | LGSTORE2_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
61 | LGSTORE2_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
62 | LGSTORE2_WALL_3_DOOR_1 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
63 | LGSTORE2_WALL_3_DOOR_2 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
64 | LGSTORE2_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
65 | LGSTORE2_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 4 | No | No |
66 | LGSTORE2_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
67 | LGSTORE2_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
68 | LGSTORE2_WALL_1_WINDOW_3 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
69 | LGSTORE2_WALL_1_WINDOW_4 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
70 | LGSTORE2_WALL_1_DOOR_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
71 | LGSTORE2_WALL_1_DOOR_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 1 | No | No |
72 | LGSTORE2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
73 | LGSTORE2_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
74 | LGSTORE2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 30.48 | 18.29 | 0.13 | 0 | No | No |
75 | SMSTORE5_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
76 | SMSTORE5_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
77 | SMSTORE5_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
78 | SMSTORE5_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
79 | SMSTORE5_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
80 | SMSTORE5_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
81 | SMSTORE5_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
82 | SMSTORE5_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
83 | SMSTORE5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
84 | SMSTORE5_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
85 | SMSTORE5_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
86 | SMSTORE6_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
87 | SMSTORE6_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
88 | SMSTORE6_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
89 | SMSTORE6_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
90 | SMSTORE6_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
91 | SMSTORE6_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
92 | SMSTORE6_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
93 | SMSTORE6_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
94 | SMSTORE6_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
95 | SMSTORE6_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
96 | SMSTORE6_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
97 | SMSTORE7_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 4 | No | No |
98 | SMSTORE7_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
99 | SMSTORE7_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
100 | SMSTORE7_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 1 | No | No |
101 | SMSTORE7_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
102 | SMSTORE7_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 3 | No | No |
103 | SMSTORE7_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
104 | SMSTORE7_WALL_4 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
105 | SMSTORE7_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
106 | SMSTORE7_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
107 | SMSTORE7_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 15.24 | 11.43 | 0.13 | 0 | No | No |
108 | SMSTORE8_WALL_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 4 | No | No |
109 | SMSTORE8_WALL_1_WINDOW_1 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
110 | SMSTORE8_WALL_1_WINDOW_2 | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
111 | SMSTORE8_WALL_1_DOOR | 0 | 473.66 | 193.24 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 1 | No | No |
112 | SMSTORE8_WALL_2 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
113 | SMSTORE8_WALL_3 | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
114 | SMSTORE8_WALL_3_DOOR | 0 | 473.66 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
115 | SMSTORE8_WALL_4 | 0 | 118.41 | 198.87 | 5.18 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 3 | No | No |
116 | SMSTORE8_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
117 | SMSTORE8_ROOF | 0 | 2090.32 | 297.18 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
118 | SMSTORE8_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 5.18 | 38.10 | 11.43 | 5.25E-002 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | LGSTORE1_INFILTRATION | TYPE1_INFIL_SCH | LGSTORE1 | 348.39 | 30.0 | 0.159 | 4.569E-004 | 2.517E-004 | 0.317 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | LGSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE1 | 348.39 | 30.0 | 0.241 | 6.922E-004 | 3.813E-004 | 0.481 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | SMSTORE1_INFILTRATION | TYPE1_INFIL_SCH | SMSTORE1 | 174.19 | 15.0 | 4.561E-002 | 2.619E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | SMSTORE1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE1 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
5 | SMSTORE2_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE2 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | SMSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE2 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
7 | SMSTORE3_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE3 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | SMSTORE3_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE3 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | SMSTORE4_INFILTRATION | TYPE2_INFIL_SCH | SMSTORE4 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | SMSTORE4_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE4 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
11 | LGSTORE2_INFILTRATION | TYPE3_INFIL_SCH | LGSTORE2 | 348.39 | 30.0 | 9.122E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | LGSTORE2_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | LGSTORE2 | 348.39 | 30.0 | 0.241 | 6.922E-004 | 4.692E-004 | 0.481 | 1.000 | 0.000 | 0.000 | 0.000 |
13 | SMSTORE5_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE5 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | SMSTORE5_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE5 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
15 | SMSTORE6_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE6 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | SMSTORE6_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE6 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
17 | SMSTORE7_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE7 | 174.19 | 15.0 | 4.561E-002 | 2.618E-004 | 1.775E-004 | 0.182 | 0.000 | 0.000 | 0.224 | 0.000 |
18 | SMSTORE7_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE7 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 5.233E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
19 | SMSTORE8_INFILTRATION | TYPE3_INFIL_SCH | SMSTORE8 | 174.19 | 15.0 | 0.113 | 6.514E-004 | 3.022E-004 | 0.453 | 0.000 | 0.000 | 0.224 | 0.000 |
20 | SMSTORE8_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | SMSTORE8 | 174.19 | 15.0 | 0.135 | 7.722E-004 | 3.583E-004 | 0.536 | 1.000 | 0.000 | 0.000 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | LGSTORE1 | Mixing/Well-Stirred |
2 | SMSTORE1 | Mixing/Well-Stirred |
3 | SMSTORE2 | Mixing/Well-Stirred |
4 | SMSTORE3 | Mixing/Well-Stirred |
5 | SMSTORE4 | Mixing/Well-Stirred |
6 | LGSTORE2 | Mixing/Well-Stirred |
7 | SMSTORE5 | Mixing/Well-Stirred |
8 | SMSTORE6 | Mixing/Well-Stirred |
9 | SMSTORE7 | Mixing/Well-Stirred |
10 | SMSTORE8 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone LGSTORE1 | 1.2000 |
3 | Zone SMSTORE1 | 1.2000 |
4 | Zone SMSTORE2 | 1.2000 |
5 | Zone SMSTORE3 | 1.2000 |
6 | Zone SMSTORE4 | 1.2000 |
7 | Zone LGSTORE2 | 1.2000 |
8 | Zone SMSTORE5 | 1.2000 |
9 | Zone SMSTORE6 | 1.2000 |
10 | Zone SMSTORE7 | 1.2000 |
11 | Zone SMSTORE8 | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | LGSTORE1 | Cooling | 19087.67287 | 22905.20744 | 1.41559 | 1.69871 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 26.32417 | 8.38408E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
2 | LGSTORE1 | Heating | 17395.88107 | 20875.05729 | 0.75795 | 0.90954 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
3 | SMSTORE1 | Cooling | 10827.12354 | 12992.54824 | 0.77825 | 0.93390 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
4 | SMSTORE1 | Heating | 8530.64945 | 10236.77934 | 0.37168 | 0.44602 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
5 | SMSTORE2 | Cooling | 10754.52731 | 12905.43277 | 0.77289 | 0.92747 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.39500 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
6 | SMSTORE2 | Heating | 8654.94804 | 10385.93764 | 0.37710 | 0.45252 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
7 | SMSTORE3 | Cooling | 10684.61311 | 12821.53573 | 0.76769 | 0.92123 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.39500 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
8 | SMSTORE3 | Heating | 8750.81521 | 10500.97825 | 0.38128 | 0.45753 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
9 | SMSTORE4 | Cooling | 10741.34817 | 12889.61781 | 0.77191 | 0.92629 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 21.39500 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
10 | SMSTORE4 | Heating | 8921.48888 | 10705.78665 | 0.38871 | 0.46646 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
11 | LGSTORE2 | Cooling | 19316.09342 | 23179.31211 | 1.38323 | 1.65987 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
12 | LGSTORE2 | Heating | 17248.70431 | 20698.44517 | 0.75154 | 0.90185 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 348.38640 | 29.99610 | 0.41145 | 0.00000 |
13 | SMSTORE5 | Cooling | 10429.61701 | 12515.54041 | 0.74887 | 0.89865 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
14 | SMSTORE5 | Heating | 9204.30859 | 11045.17031 | 0.40104 | 0.48124 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
15 | SMSTORE6 | Cooling | 10341.15009 | 12409.38011 | 0.74232 | 0.89079 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
16 | SMSTORE6 | Heating | 9202.41475 | 11042.89769 | 0.40095 | 0.48114 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
17 | SMSTORE7 | Cooling | 10178.72866 | 12214.47439 | 0.73030 | 0.87636 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
18 | SMSTORE7 | Heating | 9458.48155 | 11350.17786 | 0.41211 | 0.49453 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
19 | SMSTORE8 | Cooling | 10103.21065 | 12123.85278 | 0.72470 | 0.86963 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 22.94200 | 8.38408E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
20 | SMSTORE8 | Heating | 10921.84222 | 13106.21066 | 0.47587 | 0.57104 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | -4.30000 | 2.65759E-003 | 174.19320 | 14.99800 | 0.20573 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-AC_1:1 | Cooling | Sensible | 23775.93 | 1.69871 | 1.69871 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-AC_1:1 | Heating | Sensible | 33086.33 | 0.90954 | 0.90954 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
3 | PSZ-AC_2:2 | Cooling | Sensible | 12837.72 | 0.93993 | 0.93993 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-AC_2:2 | Heating | Sensible | 16345.30 | 0.44602 | 0.44602 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
5 | PSZ-AC_3:3 | Cooling | Sensible | 12788.33 | 0.92747 | 0.92747 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
6 | PSZ-AC_3:3 | Heating | Sensible | 16492.29 | 0.45252 | 0.45252 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
7 | PSZ-AC_4:4 | Cooling | Sensible | 12830.28 | 0.92337 | 0.92337 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
8 | PSZ-AC_4:4 | Heating | Sensible | 16605.65 | 0.45753 | 0.45753 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
9 | PSZ-AC_5:5 | Cooling | Sensible | 12764.85 | 0.92629 | 0.92629 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
10 | PSZ-AC_5:5 | Heating | Sensible | 16807.48 | 0.46646 | 0.46646 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
11 | PSZ-AC_6:6 | Cooling | Sensible | 23394.11 | 1.69097 | 1.69097 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
12 | PSZ-AC_6:6 | Heating | Sensible | 32912.30 | 0.90185 | 0.90185 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
13 | PSZ-AC_7:7 | Cooling | Sensible | 12042.98 | 0.90138 | 0.90138 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
14 | PSZ-AC_7:7 | Heating | Sensible | 17141.92 | 0.48124 | 0.48124 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
15 | PSZ-AC_8:8 | Cooling | Sensible | 11946.49 | 0.89421 | 0.89421 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
16 | PSZ-AC_8:8 | Heating | Sensible | 17139.68 | 0.48114 | 0.48114 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
17 | PSZ-AC_9:9 | Cooling | Sensible | 11829.19 | 0.88164 | 0.88164 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
18 | PSZ-AC_9:9 | Heating | Sensible | 17442.49 | 0.49453 | 0.49453 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
19 | PSZ-AC_10:10 | Cooling | Sensible | 11824.60 | 0.88330 | 0.88330 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
20 | PSZ-AC_10:10 | Heating | Sensible | 19172.92 | 0.57104 | 0.57104 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.69871 |
2 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE1 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.93390 |
3 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.92747 |
4 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE3 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.92123 |
5 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE4 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.92629 |
6 | AirTerminal:SingleDuct:Uncontrolled | LGSTORE2 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.65987 |
7 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE5 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.89865 |
8 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE6 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.89079 |
9 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE7 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.87636 |
10 | AirTerminal:SingleDuct:Uncontrolled | SMSTORE8 DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.86963 |
11 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.69871 |
12 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.69871 |
13 | AirLoopHVAC | PSZ-AC_1:1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.69871 |
14 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.69871 |
15 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.69871 |
16 | AirLoopHVAC | PSZ-AC_1:1 | Adjusted Main Design Air Flow Rate [m3/s] | 1.69871 |
17 | AirLoopHVAC | PSZ-AC_1:1 | User Heating Air Flow Ratio [] | 1.00000 |
18 | AirLoopHVAC | PSZ-AC_1:1 | Calculated Heating Air Flow Ratio [] | 1.00000 |
19 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.93390 |
20 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.93390 |
21 | AirLoopHVAC | PSZ-AC_2:2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.93390 |
22 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.93390 |
23 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.93993 |
24 | AirLoopHVAC | PSZ-AC_2:2 | Adjusted Main Design Air Flow Rate [m3/s] | 0.93993 |
25 | AirLoopHVAC | PSZ-AC_2:2 | User Heating Air Flow Ratio [] | 1.00000 |
26 | AirLoopHVAC | PSZ-AC_2:2 | Calculated Heating Air Flow Ratio [] | 0.99358 |
27 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.92747 |
28 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.92747 |
29 | AirLoopHVAC | PSZ-AC_3:3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.92747 |
30 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.92747 |
31 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92747 |
32 | AirLoopHVAC | PSZ-AC_3:3 | Adjusted Main Design Air Flow Rate [m3/s] | 0.92747 |
33 | AirLoopHVAC | PSZ-AC_3:3 | User Heating Air Flow Ratio [] | 1.00000 |
34 | AirLoopHVAC | PSZ-AC_3:3 | Calculated Heating Air Flow Ratio [] | 1.00000 |
35 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.92123 |
36 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.92123 |
37 | AirLoopHVAC | PSZ-AC_4:4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.92123 |
38 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.92123 |
39 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92337 |
40 | AirLoopHVAC | PSZ-AC_4:4 | Adjusted Main Design Air Flow Rate [m3/s] | 0.92337 |
41 | AirLoopHVAC | PSZ-AC_4:4 | User Heating Air Flow Ratio [] | 1.00000 |
42 | AirLoopHVAC | PSZ-AC_4:4 | Calculated Heating Air Flow Ratio [] | 0.99768 |
43 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.92629 |
44 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.92629 |
45 | AirLoopHVAC | PSZ-AC_5:5 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.92629 |
46 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.92629 |
47 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.92629 |
48 | AirLoopHVAC | PSZ-AC_5:5 | Adjusted Main Design Air Flow Rate [m3/s] | 0.92629 |
49 | AirLoopHVAC | PSZ-AC_5:5 | User Heating Air Flow Ratio [] | 1.00000 |
50 | AirLoopHVAC | PSZ-AC_5:5 | Calculated Heating Air Flow Ratio [] | 1.00000 |
51 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.65987 |
52 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.65987 |
53 | AirLoopHVAC | PSZ-AC_6:6 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.65987 |
54 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Heating Design Air Flow Rate [m3/s] | 1.65987 |
55 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.69097 |
56 | AirLoopHVAC | PSZ-AC_6:6 | Adjusted Main Design Air Flow Rate [m3/s] | 1.69097 |
57 | AirLoopHVAC | PSZ-AC_6:6 | User Heating Air Flow Ratio [] | 1.00000 |
58 | AirLoopHVAC | PSZ-AC_6:6 | Calculated Heating Air Flow Ratio [] | 0.98161 |
59 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.89865 |
60 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.89865 |
61 | AirLoopHVAC | PSZ-AC_7:7 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.89865 |
62 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.89865 |
63 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.90138 |
64 | AirLoopHVAC | PSZ-AC_7:7 | Adjusted Main Design Air Flow Rate [m3/s] | 0.90138 |
65 | AirLoopHVAC | PSZ-AC_7:7 | User Heating Air Flow Ratio [] | 1.00000 |
66 | AirLoopHVAC | PSZ-AC_7:7 | Calculated Heating Air Flow Ratio [] | 0.99697 |
67 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.89079 |
68 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.89079 |
69 | AirLoopHVAC | PSZ-AC_8:8 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.89079 |
70 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.89079 |
71 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.89421 |
72 | AirLoopHVAC | PSZ-AC_8:8 | Adjusted Main Design Air Flow Rate [m3/s] | 0.89421 |
73 | AirLoopHVAC | PSZ-AC_8:8 | User Heating Air Flow Ratio [] | 1.00000 |
74 | AirLoopHVAC | PSZ-AC_8:8 | Calculated Heating Air Flow Ratio [] | 0.99618 |
75 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.87636 |
76 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.87636 |
77 | AirLoopHVAC | PSZ-AC_9:9 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.87636 |
78 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.87636 |
79 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.88164 |
80 | AirLoopHVAC | PSZ-AC_9:9 | Adjusted Main Design Air Flow Rate [m3/s] | 0.88164 |
81 | AirLoopHVAC | PSZ-AC_9:9 | User Heating Air Flow Ratio [] | 1.00000 |
82 | AirLoopHVAC | PSZ-AC_9:9 | Calculated Heating Air Flow Ratio [] | 0.99401 |
83 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.86963 |
84 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.86963 |
85 | AirLoopHVAC | PSZ-AC_10:10 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.86963 |
86 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.86963 |
87 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.88330 |
88 | AirLoopHVAC | PSZ-AC_10:10 | Adjusted Main Design Air Flow Rate [m3/s] | 0.88330 |
89 | AirLoopHVAC | PSZ-AC_10:10 | User Heating Air Flow Ratio [] | 1.00000 |
90 | AirLoopHVAC | PSZ-AC_10:10 | Calculated Heating Air Flow Ratio [] | 0.98452 |
91 | AirLoopHVAC | PSZ-AC_1:1 | Design Supply Air Flow Rate [m3/s] | 1.69871 |
92 | AirLoopHVAC | PSZ-AC_2:2 | Design Supply Air Flow Rate [m3/s] | 0.93993 |
93 | AirLoopHVAC | PSZ-AC_3:3 | Design Supply Air Flow Rate [m3/s] | 0.92747 |
94 | AirLoopHVAC | PSZ-AC_4:4 | Design Supply Air Flow Rate [m3/s] | 0.92337 |
95 | AirLoopHVAC | PSZ-AC_5:5 | Design Supply Air Flow Rate [m3/s] | 0.92629 |
96 | AirLoopHVAC | PSZ-AC_6:6 | Design Supply Air Flow Rate [m3/s] | 1.69097 |
97 | AirLoopHVAC | PSZ-AC_7:7 | Design Supply Air Flow Rate [m3/s] | 0.90138 |
98 | AirLoopHVAC | PSZ-AC_8:8 | Design Supply Air Flow Rate [m3/s] | 0.89421 |
99 | AirLoopHVAC | PSZ-AC_9:9 | Design Supply Air Flow Rate [m3/s] | 0.88164 |
100 | AirLoopHVAC | PSZ-AC_10:10 | Design Supply Air Flow Rate [m3/s] | 0.88330 |
101 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.69871 |
102 | Controller:OutdoorAir | PSZ-AC_1:1_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
103 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.69871 |
104 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.69871 |
105 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.69871 |
106 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.69871 |
107 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.69871 |
108 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.84936 |
109 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.69871 |
110 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 28119.68217 |
111 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 28119.71000 |
112 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 14059.85500 |
113 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 28119.71000 |
114 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
115 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
116 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
117 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
118 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 28119.71000 |
119 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 50934.81824 |
120 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
121 | AirLoopHVAC:UnitarySystem | PSZ-AC_1:1_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
122 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.69871 |
123 | Fan:SystemModel | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1817.70187 |
124 | Coil:Heating:Fuel | PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 50934.81824 |
125 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.93993 |
126 | Controller:OutdoorAir | PSZ-AC_2:2_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
127 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.93993 |
128 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.93993 |
129 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.93993 |
130 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.93993 |
131 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.93993 |
132 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46997 |
133 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.93993 |
134 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15559.17894 |
135 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15559.14000 |
136 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7779.57000 |
137 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15559.14000 |
138 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
139 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
140 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
141 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
142 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15559.14000 |
143 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27379.57069 |
144 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
145 | AirLoopHVAC:UnitarySystem | PSZ-AC_2:2_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
146 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.93993 |
147 | Fan:SystemModel | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1040.64918 |
148 | Coil:Heating:Fuel | PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27379.57069 |
149 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92747 |
150 | Controller:OutdoorAir | PSZ-AC_3:3_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
151 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92747 |
152 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92747 |
153 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92747 |
154 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92747 |
155 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.92747 |
156 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46374 |
157 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.92747 |
158 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15352.92170 |
159 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15352.84000 |
160 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7676.42000 |
161 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15352.84000 |
162 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
163 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
164 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
165 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
166 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15352.84000 |
167 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27234.11808 |
168 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
169 | AirLoopHVAC:UnitarySystem | PSZ-AC_3:3_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
170 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.92747 |
171 | Fan:SystemModel | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1026.85099 |
172 | Coil:Heating:Fuel | PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27234.11808 |
173 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92337 |
174 | Controller:OutdoorAir | PSZ-AC_4:4_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
175 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92337 |
176 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92337 |
177 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92337 |
178 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92337 |
179 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.92337 |
180 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46169 |
181 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.92337 |
182 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15285.05214 |
183 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15284.97000 |
184 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7642.48500 |
185 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15284.97000 |
186 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
187 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
188 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
189 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
190 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15284.97000 |
191 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27093.00560 |
192 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
193 | AirLoopHVAC:UnitarySystem | PSZ-AC_4:4_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
194 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.92337 |
195 | Fan:SystemModel | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1022.31165 |
196 | Coil:Heating:Fuel | PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27093.00560 |
197 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.92629 |
198 | Controller:OutdoorAir | PSZ-AC_5:5_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
199 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.92629 |
200 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.92629 |
201 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.92629 |
202 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.92629 |
203 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.92629 |
204 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.46315 |
205 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.92629 |
206 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 15333.38851 |
207 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 15333.36000 |
208 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7666.68000 |
209 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 15333.36000 |
210 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
211 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
212 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
213 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
214 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 15333.36000 |
215 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 27207.49573 |
216 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
217 | AirLoopHVAC:UnitarySystem | PSZ-AC_5:5_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
218 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.92629 |
219 | Fan:SystemModel | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1025.54787 |
220 | Coil:Heating:Fuel | PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 27207.49573 |
221 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.69097 |
222 | Controller:OutdoorAir | PSZ-AC_6:6_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.41145 |
223 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.69097 |
224 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.69097 |
225 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.69097 |
226 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.69097 |
227 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.69097 |
228 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.84549 |
229 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.69097 |
230 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 27991.55769 |
231 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 27991.62000 |
232 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 13995.81000 |
233 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 27991.62000 |
234 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
235 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
236 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
237 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
238 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 27991.62000 |
239 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 50056.32256 |
240 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
241 | AirLoopHVAC:UnitarySystem | PSZ-AC_6:6_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
242 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.69097 |
243 | Fan:SystemModel | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 1809.42179 |
244 | Coil:Heating:Fuel | PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 50056.32256 |
245 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.90138 |
246 | Controller:OutdoorAir | PSZ-AC_7:7_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
247 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.90138 |
248 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.90138 |
249 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.90138 |
250 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.90138 |
251 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.90138 |
252 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.45069 |
253 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.90138 |
254 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 14921.03956 |
255 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 14921.05000 |
256 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7460.52500 |
257 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14921.05000 |
258 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
259 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
260 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
261 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
262 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 14921.05000 |
263 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26582.34566 |
264 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
265 | AirLoopHVAC:UnitarySystem | PSZ-AC_7:7_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
266 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.90138 |
267 | Fan:SystemModel | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 997.97126 |
268 | Coil:Heating:Fuel | PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 26582.34566 |
269 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.89421 |
270 | Controller:OutdoorAir | PSZ-AC_8:8_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
271 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.89421 |
272 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.89421 |
273 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.89421 |
274 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.89421 |
275 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.89421 |
276 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.44711 |
277 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.89421 |
278 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 14802.35060 |
279 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 14802.29000 |
280 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7401.14500 |
281 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14802.29000 |
282 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79866 |
283 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
284 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
285 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
286 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 14802.29000 |
287 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26404.62064 |
288 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
289 | AirLoopHVAC:UnitarySystem | PSZ-AC_8:8_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
290 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.89421 |
291 | Fan:SystemModel | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 990.02822 |
292 | Coil:Heating:Fuel | PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 26404.62064 |
293 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.88164 |
294 | Controller:OutdoorAir | PSZ-AC_9:9_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
295 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.88164 |
296 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.88164 |
297 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.88164 |
298 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.88164 |
299 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.88164 |
300 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.44082 |
301 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.88164 |
302 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 14594.27247 |
303 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 14594.33000 |
304 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7297.16500 |
305 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14594.33000 |
306 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
307 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
308 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
309 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
310 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 14594.33000 |
311 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 26078.35346 |
312 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
313 | AirLoopHVAC:UnitarySystem | PSZ-AC_9:9_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
314 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.88164 |
315 | Fan:SystemModel | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 976.11899 |
316 | Coil:Heating:Fuel | PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 26078.35346 |
317 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.88330 |
318 | Controller:OutdoorAir | PSZ-AC_10:10_OA_CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.20573 |
319 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.88330 |
320 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.88330 |
321 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.88330 |
322 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.88330 |
323 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.88330 |
324 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.44165 |
325 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.88330 |
326 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 14621.75137 |
327 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 14621.82000 |
328 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 7310.91000 |
329 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 14621.82000 |
330 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79865 |
331 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79866 |
332 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79866 |
333 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79866 |
334 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 14621.82000 |
335 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 25926.22709 |
336 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
337 | AirLoopHVAC:UnitarySystem | PSZ-AC_10:10_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
338 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.88330 |
339 | Fan:SystemModel | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Design Electric Power Consumption [W] | 977.95804 |
340 | Coil:Heating:Fuel | PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Design Size Nominal Capacity [W] | 25926.22709 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 26788.4 | 10.74 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 14822.5 | 30.88 | |||
3 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 14626.0 | 42.30 | |||
4 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 14561.3 | 53.49 | |||
5 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 14607.4 | 64.32 | |||
6 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 26666.4 | 45.13 | |||
7 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 14214.6 | 97.74 | |||
8 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 14101.5 | 109.53 | |||
9 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 13903.4 | 122.09 | |||
10 | Coil:Cooling:DX:MultiSpeed | PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 13929.6 | 132.86 |
Zone Name | # Surfaces | |
1 | LGSTORE1 | 15 |
2 | SMSTORE1 | 11 |
3 | SMSTORE2 | 11 |
4 | SMSTORE3 | 11 |
5 | SMSTORE4 | 11 |
6 | LGSTORE2 | 15 |
7 | SMSTORE5 | 11 |
8 | SMSTORE6 | 11 |
9 | SMSTORE7 | 11 |
10 | SMSTORE8 | 11 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | LGSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | LGSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 71.15 | 78.94 | 71.15 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | LGSTORE1_WALL_3_DOOR_1 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
4 | LGSTORE1_WALL_3_DOOR_2 | Door | LGSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
5 | LGSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
6 | LGSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 58.20 | 78.94 | 58.20 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
7 | LGSTORE1_WALL_1_WINDOW_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
8 | LGSTORE1_WALL_1_WINDOW_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
9 | LGSTORE1_WALL_1_WINDOW_3 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
10 | LGSTORE1_WALL_1_WINDOW_4 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
11 | LGSTORE1_WALL_1_DOOR_1 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
12 | LGSTORE1_WALL_1_DOOR_2 | Window | LGSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
13 | LGSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE1_FLOOR_FFACTOR | 0.146 | 0.141 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | LGSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
15 | LGSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
16 | SMSTORE1_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.10 | 39.47 | 29.10 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
17 | SMSTORE1_WALL_1_WINDOW_1 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
18 | SMSTORE1_WALL_1_WINDOW_2 | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
19 | SMSTORE1_WALL_1_DOOR | Window | SMSTORE1_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.90 | 3.90 | 3.90 | 180.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
20 | SMSTORE1_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | SMSTORE1_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.57 | 39.47 | 35.57 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | SMSTORE1_WALL_3_DOOR | Door | SMSTORE1_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.90 | 3.90 | 3.90 | 0.00 | 90.00 | 1.83 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
23 | SMSTORE1_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
24 | SMSTORE1_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE1_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | SMSTORE1_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
26 | SMSTORE1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
27 | SMSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
28 | SMSTORE2_WALL_1_WINDOW_1 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
29 | SMSTORE2_WALL_1_WINDOW_2 | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
30 | SMSTORE2_WALL_1_DOOR | Window | SMSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
31 | SMSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE1_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
32 | SMSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | SMSTORE2_WALL_3_DOOR | Door | SMSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
34 | SMSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | SMSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE2_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
36 | SMSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
37 | SMSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
38 | SMSTORE3_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
39 | SMSTORE3_WALL_1_WINDOW_1 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
40 | SMSTORE3_WALL_1_WINDOW_2 | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
41 | SMSTORE3_WALL_1_DOOR | Window | SMSTORE3_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
42 | SMSTORE3_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
43 | SMSTORE3_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
44 | SMSTORE3_WALL_3_DOOR | Door | SMSTORE3_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
45 | SMSTORE3_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
46 | SMSTORE3_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE3_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
47 | SMSTORE3_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
48 | SMSTORE3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
49 | SMSTORE4_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | SMSTORE4_WALL_1_WINDOW_1 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
51 | SMSTORE4_WALL_1_WINDOW_2 | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
52 | SMSTORE4_WALL_1_DOOR | Window | SMSTORE4_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
53 | SMSTORE4_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE3_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | SMSTORE4_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | SMSTORE4_WALL_3_DOOR | Door | SMSTORE4_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
56 | SMSTORE4_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | SMSTORE4_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE4_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | SMSTORE4_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | SMSTORE4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | LGSTORE2_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE4_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | LGSTORE2_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 71.19 | 78.94 | 71.19 | 0.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
62 | LGSTORE2_WALL_3_DOOR_1 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
63 | LGSTORE2_WALL_3_DOOR_2 | Door | LGSTORE2_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
64 | LGSTORE2_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | LGSTORE2_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 58.24 | 78.94 | 58.24 | 180.00 | 90.00 | 15.24 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
66 | LGSTORE2_WALL_1_WINDOW_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
67 | LGSTORE2_WALL_1_WINDOW_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
68 | LGSTORE2_WALL_1_WINDOW_3 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
69 | LGSTORE2_WALL_1_WINDOW_4 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | LGSTORE2_WALL_1_DOOR_1 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
71 | LGSTORE2_WALL_1_DOOR_2 | Window | LGSTORE2_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
72 | LGSTORE2_FLOOR | Floor | CTF - ConductionTransferFunction | LGSTORE2_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 348.39 | 348.39 | 348.39 | 270.00 | 180.00 | 22.86 | 15.24 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
73 | LGSTORE2_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 348.39 | 348.39 | 348.39 | 270.00 | 0.00 | 22.86 | 15.24 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
74 | LGSTORE2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 696.77 | 696.77 | 696.77 | 0.00 | 90.00 | 696.77 | 1.00 | 0.00 | LGSTORE2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
75 | SMSTORE5_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
76 | SMSTORE5_WALL_1_WINDOW_1 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
77 | SMSTORE5_WALL_1_WINDOW_2 | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | SMSTORE5_WALL_1_DOOR | Window | SMSTORE5_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
79 | SMSTORE5_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | LGSTORE2_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | SMSTORE5_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | SMSTORE5_WALL_3_DOOR | Door | SMSTORE5_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
82 | SMSTORE5_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
83 | SMSTORE5_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE5_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
84 | SMSTORE5_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
85 | SMSTORE5_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE5_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
86 | SMSTORE6_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | SMSTORE6_WALL_1_WINDOW_1 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
88 | SMSTORE6_WALL_1_WINDOW_2 | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
89 | SMSTORE6_WALL_1_DOOR | Window | SMSTORE6_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
90 | SMSTORE6_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE5_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
91 | SMSTORE6_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
92 | SMSTORE6_WALL_3_DOOR | Door | SMSTORE6_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
93 | SMSTORE6_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
94 | SMSTORE6_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE6_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
95 | SMSTORE6_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
96 | SMSTORE6_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE6_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
97 | SMSTORE7_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
98 | SMSTORE7_WALL_1_WINDOW_1 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
99 | SMSTORE7_WALL_1_WINDOW_2 | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
100 | SMSTORE7_WALL_1_DOOR | Window | SMSTORE7_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
101 | SMSTORE7_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE6_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
102 | SMSTORE7_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.59 | 39.47 | 35.59 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
103 | SMSTORE7_WALL_3_DOOR | Door | SMSTORE7_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
104 | SMSTORE7_WALL_4 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE8_WALL_2 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | SMSTORE7_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE7_FLOOR_FFACTOR | 8.283E-002 | 8.119E-002 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
106 | SMSTORE7_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
107 | SMSTORE7_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE7_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
108 | SMSTORE8_WALL_1 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 29.12 | 39.47 | 29.12 | 180.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | SMSTORE8_WALL_1_WINDOW_1 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
110 | SMSTORE8_WALL_1_WINDOW_2 | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.24 | 3.24 | 3.24 | 180.00 | 90.00 | 2.13 | 1.52 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
111 | SMSTORE8_WALL_1_DOOR | Window | SMSTORE8_WALL_1 | Window5 Detailed Fenestration | NONRESWINDOW_U_0.38_SHGC_0.4 | N/A | 2.159 | No | 3.88 | 3.88 | 3.88 | 180.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
112 | SMSTORE8_WALL_2 | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 118.41 | 118.41 | 118.41 | 270.00 | 90.00 | 22.86 | 5.18 | 0.00 | SMSTORE7_WALL_4 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
113 | SMSTORE8_WALL_3 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 35.60 | 39.47 | 35.60 | 0.00 | 90.00 | 7.62 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
114 | SMSTORE8_WALL_3_DOOR | Door | SMSTORE8_WALL_3 | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 3.88 | 3.88 | 3.88 | 0.00 | 90.00 | 1.82 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
115 | SMSTORE8_WALL_4 | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL | 0.384 | 0.363 | 118.41 | 118.41 | 118.41 | 90.00 | 90.00 | 22.86 | 5.18 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
116 | SMSTORE8_FLOOR | Floor | CTF - ConductionTransferFunction | SMSTORE8_FLOOR_FFACTOR | 0.211 | 0.201 | 174.19 | 174.19 | 174.19 | 270.00 | 180.00 | 22.86 | 7.62 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
117 | SMSTORE8_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.228 | 0.219 | 174.19 | 174.19 | 174.19 | 270.00 | 0.00 | 22.86 | 7.62 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
118 | SMSTORE8_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 348.39 | 348.39 | 348.39 | 0.00 | 90.00 | 348.39 | 1.00 | 0.00 | SMSTORE8_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
3 | CHRISTMAS | Holiday | InputFile | 12/25 | 1 |
4 | INDEPENDENCE DAY | Holiday | InputFile | 07/04 | 1 |
5 | MLK DAY | Holiday | InputFile | 01/16 | 1 |
6 | PRESIDENTS DAY | Holiday | InputFile | 02/20 | 1 |
7 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
8 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
9 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
10 | THANKSGIVING | Holiday | InputFile | 11/23 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 11 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | LGSTORE1 | RunPeriod: RUNPERIOD 1 | 1.4848804245E-002 | 3.0950413865E-002 | Pass | Pass | 0.6677980788 | 4.7147784663 | Pass | Pass |
2 | SMSTORE1 | RunPeriod: RUNPERIOD 1 | 4.7597256670E-002 | 9.5458029297E-002 | Pass | Pass | 0.1304612617 | 0.4952767057 | Pass | Pass |
3 | SMSTORE2 | RunPeriod: RUNPERIOD 1 | 1.7126472382E-002 | 3.1151362322E-002 | Pass | Pass | 0.2585058948 | 1.8788989133 | Pass | Pass |
4 | SMSTORE3 | RunPeriod: RUNPERIOD 1 | 2.2542465768E-002 | 5.8699222469E-002 | Pass | Pass | 7.8583320050E-002 | 0.2733326188 | Pass | Pass |
5 | SMSTORE4 | RunPeriod: RUNPERIOD 1 | 2.6837644798E-002 | 8.5396698240E-002 | Pass | Pass | 0.1491398153 | 0.8345183421 | Pass | Pass |
6 | LGSTORE2 | RunPeriod: RUNPERIOD 1 | 3.5130651114E-002 | 0.1032354394 | Pass | Pass | 7.2230718381E-002 | 0.2558740192 | Pass | Pass |
7 | SMSTORE5 | RunPeriod: RUNPERIOD 1 | 3.5762096720E-002 | 0.1072883788 | Pass | Pass | 0.4892280940 | 4.9734441290 | Pass | Pass |
8 | SMSTORE6 | RunPeriod: RUNPERIOD 1 | 3.8927766349E-002 | 0.1173895150 | Pass | Pass | 0.1455776235 | 0.5954511966 | Pass | Pass |
9 | SMSTORE7 | RunPeriod: RUNPERIOD 1 | 4.2792907860E-002 | 0.1513595230 | Pass | Pass | 7.6763469722E-002 | 0.2472666949 | Pass | Pass |
10 | SMSTORE8 | RunPeriod: RUNPERIOD 1 | 6.7721624421E-002 | 0.2554490399 | Pass | Pass | 0.1143400919 | 0.6226663744 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | -4.30 | 0.00 | -4.30 | Wetbulb [C] | 1.20 | 110.00 |
WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 26.40 | 9.10 | 17.00 | Wetbulb [C] | 2.10 | 90.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_2 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 118.41 | 118.41 | 270.00 | 90.00 | W |
LGSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 71.15 | 0.00 | 90.00 | N |
LGSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 58.20 | 180.00 | 90.00 | S |
LGSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE1_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.10 | 180.00 | 90.00 | S |
SMSTORE1_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.57 | 0.00 | 90.00 | N |
SMSTORE1_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE3_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE3_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE3_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE4_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE4_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE4_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE2_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 71.19 | 0.00 | 90.00 | N |
LGSTORE2_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 78.94 | 58.24 | 180.00 | 90.00 | S |
LGSTORE2_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 348.39 | 348.39 | 270.00 | 0.00 | |
SMSTORE5_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE5_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE5_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE6_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE6_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE6_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE7_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE7_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.59 | 0.00 | 90.00 | N |
SMSTORE7_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
SMSTORE8_WALL_1 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 29.12 | 180.00 | 90.00 | S |
SMSTORE8_WALL_3 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 39.47 | 35.60 | 0.00 | 90.00 | N |
SMSTORE8_WALL_4 | NONRES_EXT_WALL | 0.30 | 0.363 | 0.384 | 118.41 | 118.41 | 90.00 | 90.00 | E |
SMSTORE8_ROOF | NONRES_ROOF | 0.23 | 0.221 | 0.228 | 174.19 | 174.19 | 270.00 | 0.00 | |
LGSTORE1_FLOOR | LGSTORE1_FLOOR_FFACTOR | 1.00 | 0.146 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE1_FLOOR | SMSTORE1_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE2_FLOOR | SMSTORE2_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE3_FLOOR | SMSTORE3_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE4_FLOOR | SMSTORE4_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
LGSTORE2_FLOOR | LGSTORE2_FLOOR_FFACTOR | 1.00 | 0.083 | 348.39 | 348.39 | 270.00 | 180.00 | ||
SMSTORE5_FLOOR | SMSTORE5_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE6_FLOOR | SMSTORE6_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE7_FLOOR | SMSTORE7_FLOOR_FFACTOR | 1.00 | 0.083 | 174.19 | 174.19 | 270.00 | 180.00 | ||
SMSTORE8_FLOOR | SMSTORE8_FLOOR_FFACTOR | 1.00 | 0.211 | 174.19 | 174.19 | 270.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
LGSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.159 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE1_WALL_1_DOOR_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.159 | 0.394 | 0.401 | No | LGSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE1_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.90 | 0.00 | 0.00 | 3.90 | 3.90 | 2.159 | 0.394 | 0.401 | No | SMSTORE1_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE2_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE3_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE3_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE4_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE4_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_3 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_WINDOW_4 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
LGSTORE2_WALL_1_DOOR_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | LGSTORE2_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE5_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE5_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE6_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE6_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE7_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE7_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_1 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_WINDOW_2 | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.24 | 0.00 | 0.00 | 3.24 | 3.24 | 2.159 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
SMSTORE8_WALL_1_DOOR | NONRESWINDOW_U_0.38_SHGC_0.4 | 3.88 | 0.00 | 0.00 | 3.88 | 3.88 | 2.159 | 0.394 | 0.401 | No | SMSTORE8_WALL_1 | 180.00 | 90.00 | S | ||
Total or Average | 124.29 | 2.159 | 0.394 | 0.401 | ||||||||||||
North Total or Average | 0.00 | - | - | - | ||||||||||||
Non-North Total or Average | 124.29 | 2.159 | 0.394 | 0.401 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
LGSTORE1_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
LGSTORE1_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | LGSTORE1_WALL_3 |
SMSTORE1_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.90 | SMSTORE1_WALL_3 |
SMSTORE2_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE2_WALL_3 |
SMSTORE3_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE3_WALL_3 |
SMSTORE4_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE4_WALL_3 |
LGSTORE2_WALL_3_DOOR_1 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
LGSTORE2_WALL_3_DOOR_2 | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | LGSTORE2_WALL_3 |
SMSTORE5_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE5_WALL_3 |
SMSTORE6_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE6_WALL_3 |
SMSTORE7_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE7_WALL_3 |
SMSTORE8_WALL_3_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 3.88 | SMSTORE8_WALL_3 |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
LGSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE1_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE1_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE2_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE3_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE4_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_WINDOW_4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
LGSTORE2_WALL_1_DOOR_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE5_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE6_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE7_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_WINDOW_2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SMSTORE8_WALL_1_DOOR | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
LGSTORE1_LIGHTS | LGSTORE1 | 15.8795 | 348.39 | 5532.19 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 102.16 |
LGSTORE1_LIGHTS_ALLOWANCE | LGSTORE1 | 5.1990 | 348.39 | 1811.25 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 33.45 |
SMSTORE1_LIGHTS | SMSTORE1 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 51.08 |
SMSTORE1_LIGHTS_ALLOWANCE | SMSTORE1 | 6.6413 | 174.19 | 1156.88 | LightsWired | TYPE1_LIGHT_SCH | 98.40 | 168.00 | 98.38 | 0.0000 | Y | 21.36 |
SMSTORE2_LIGHTS | SMSTORE2 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 40.48 |
SMSTORE2_LIGHTS_ALLOWANCE | SMSTORE2 | 4.4886 | 174.19 | 781.88 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 11.44 |
SMSTORE3_LIGHTS | SMSTORE3 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 40.48 |
SMSTORE3_LIGHTS_ALLOWANCE | SMSTORE3 | 4.4886 | 174.19 | 781.88 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 11.44 |
SMSTORE4_LIGHTS | SMSTORE4 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 40.48 |
SMSTORE4_LIGHTS_ALLOWANCE | SMSTORE4 | 4.4886 | 174.19 | 781.88 | LightsWired | TYPE2_LIGHT_SCH | 78.55 | 168.00 | 77.96 | 0.0000 | Y | 11.44 |
LGSTORE2_LIGHTS | LGSTORE2 | 15.8795 | 348.39 | 5532.19 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 74.42 |
LGSTORE2_LIGHTS_ALLOWANCE | LGSTORE2 | 0.0000 | 348.39 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE5_LIGHTS | SMSTORE5 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 37.21 |
SMSTORE5_LIGHTS_ALLOWANCE | SMSTORE5 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE6_LIGHTS | SMSTORE6 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 37.21 |
SMSTORE6_LIGHTS_ALLOWANCE | SMSTORE6 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE7_LIGHTS | SMSTORE7 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 37.21 |
SMSTORE7_LIGHTS_ALLOWANCE | SMSTORE7 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
SMSTORE8_LIGHTS | SMSTORE8 | 15.8795 | 174.19 | 2766.09 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 168.00 | 71.66 | 0.0000 | Y | 37.21 |
SMSTORE8_LIGHTS_ALLOWANCE | SMSTORE8 | 0.0000 | 174.19 | 0.00 | LightsWired | TYPE3_LIGHT_SCH | 72.25 | 0.00 | 0.0000 | Y | 0.00 | |
Interior Lighting Total | 9.2108 | 4180.64 | 38506.89 | 587.06 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7048.38 | AstronomicalClock | - | 83.54 | 83.54 | 110.53 | |
Exterior Lighting Total | 7048.38 | 110.53 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 28119.71 | 22458.09 | 5661.62 | 0.80 | 3.80 | |||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15559.14 | 12426.46 | 3132.68 | 0.80 | 3.91 | |||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15352.84 | 12261.70 | 3091.14 | 0.80 | 3.91 | |||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15284.97 | 12207.49 | 3077.48 | 0.80 | 3.91 | |||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 15333.36 | 12246.14 | 3087.22 | 0.80 | 3.91 | |||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 27991.62 | 22355.79 | 5635.83 | 0.80 | 3.80 | |||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 14921.05 | 11916.85 | 3004.20 | 0.80 | 3.91 | |||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 14802.29 | 11822.00 | 2980.29 | 0.80 | 3.91 | |||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 14594.33 | 11655.91 | 2938.42 | 0.80 | 3.91 | |||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | 14621.82 | 11677.86 | 2943.96 | 0.80 | 3.91 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | 26788.4 | 10.74 | ||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | 14822.5 | 30.88 | ||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | 14626.0 | 42.30 | ||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | 14561.3 | 53.49 | ||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | 14607.4 | 64.32 | ||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | 26666.4 | 45.13 | ||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | 14214.6 | 97.74 | ||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | 14101.5 | 109.53 | ||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | 13903.4 | 122.09 | ||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | 13929.6 | 132.86 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 50934.82 | 0.80 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27379.57 | 0.80 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27234.12 | 0.80 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27093.01 | 0.80 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 27207.50 | 0.80 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 50056.32 | 0.80 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 26582.35 | 0.80 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 26404.62 | 0.80 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 26078.35 | 0.80 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | 25926.23 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.70 | 1817.70 | 1070.05 | 1.00 | 1.34 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 |
PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.94 | 1040.65 | 1107.16 | 1.00 | 1.42 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.93 | 1026.85 | 1107.16 | 1.00 | 1.42 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.92 | 1022.31 | 1107.16 | 1.00 | 1.42 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 |
PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.93 | 1025.55 | 1107.16 | 1.00 | 1.42 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 |
PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.58 | 622.50 | 1.69 | 1809.42 | 1070.05 | 1.00 | 1.34 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.90 | 997.97 | 1107.16 | 1.00 | 1.43 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.89 | 990.03 | 1107.16 | 1.00 | 1.43 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.88 | 976.12 | 1107.16 | 1.00 | 1.44 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.56 | 622.50 | 0.88 | 977.96 | 1107.16 | 1.00 | 1.43 | General | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
GAS TANK1 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK2 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK3 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK4 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK5 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK6 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
GAS TANK7 | WaterHeater:Mixed | 0.15 | 11722.84 | 1.00 | 1.02 | 0.72 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 19087.67 | 22905.21 | 65.75 | 1.416 | 1.699 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 23.89 | 23.89 | 0.00878 | 26.32 | 0.00838 | 0.411 | 0.00 |
SMSTORE1 | 10827.12 | 12992.55 | 74.59 | 0.778 | 0.934 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00897 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE2 | 10754.53 | 12905.43 | 74.09 | 0.773 | 0.927 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00924 | 21.39 | 0.00838 | 0.206 | 0.00 |
SMSTORE3 | 10684.61 | 12821.54 | 73.61 | 0.768 | 0.921 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00921 | 21.39 | 0.00838 | 0.206 | 0.00 |
SMSTORE4 | 10741.35 | 12889.62 | 74.00 | 0.772 | 0.926 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 23.89 | 23.89 | 0.00923 | 21.39 | 0.00838 | 0.206 | 0.00 |
LGSTORE2 | 19316.09 | 23179.31 | 66.53 | 1.383 | 1.660 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00915 | 22.94 | 0.00838 | 0.411 | 0.00 |
SMSTORE5 | 10429.62 | 12515.54 | 71.85 | 0.749 | 0.899 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00908 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE6 | 10341.15 | 12409.38 | 71.24 | 0.742 | 0.891 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00910 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE7 | 10178.73 | 12214.47 | 70.12 | 0.730 | 0.876 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00915 | 22.94 | 0.00838 | 0.206 | 0.00 |
SMSTORE8 | 10103.21 | 12123.85 | 69.60 | 0.725 | 0.870 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.89 | 0.00916 | 22.94 | 0.00838 | 0.206 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
LGSTORE1 | 17395.88 | 20875.06 | 59.92 | 0.758 | 0.910 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00682 | -4.30 | 0.00266 | 0.411 | 0.00 |
SMSTORE1 | 8530.65 | 10236.78 | 58.77 | 0.372 | 0.446 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00670 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE2 | 8654.95 | 10385.94 | 59.62 | 0.377 | 0.453 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00671 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE3 | 8750.82 | 10500.98 | 60.28 | 0.381 | 0.458 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00671 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE4 | 8921.49 | 10705.79 | 61.46 | 0.389 | 0.466 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00673 | -4.30 | 0.00266 | 0.206 | 0.00 |
LGSTORE2 | 17248.70 | 20698.45 | 59.41 | 0.752 | 0.902 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00682 | -4.30 | 0.00266 | 0.411 | 0.00 |
SMSTORE5 | 9204.31 | 11045.17 | 63.41 | 0.401 | 0.481 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00675 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE6 | 9202.41 | 11042.90 | 63.39 | 0.401 | 0.481 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00675 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE7 | 9458.48 | 11350.18 | 65.16 | 0.412 | 0.495 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00677 | -4.30 | 0.00266 | 0.206 | 0.00 |
SMSTORE8 | 10921.84 | 13106.21 | 75.24 | 0.476 | 0.571 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 21.11 | 21.11 | 0.00686 | -4.30 | 0.00266 | 0.206 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-AC_1:1 | 1.70 | 1.70 | 0.91 | 0.91 | 1.6987 | 1.6987 | 1.6987 | 1.0000 | 1.0000 |
PSZ-AC_2:2 | 0.94 | 0.94 | 0.45 | 0.45 | 0.9399 | 0.9339 | 0.9399 | 0.9936 | 1.0000 |
PSZ-AC_3:3 | 0.93 | 0.93 | 0.45 | 0.45 | 0.9275 | 0.9275 | 0.9275 | 1.0000 | 1.0000 |
PSZ-AC_4:4 | 0.92 | 0.92 | 0.46 | 0.46 | 0.9234 | 0.9212 | 0.9234 | 0.9977 | 1.0000 |
PSZ-AC_5:5 | 0.93 | 0.93 | 0.47 | 0.47 | 0.9263 | 0.9263 | 0.9263 | 1.0000 | 1.0000 |
PSZ-AC_6:6 | 1.69 | 1.69 | 0.90 | 0.90 | 1.6910 | 1.6599 | 1.6910 | 0.9816 | 1.0000 |
PSZ-AC_7:7 | 0.90 | 0.90 | 0.48 | 0.48 | 0.9014 | 0.8986 | 0.9014 | 0.9970 | 1.0000 |
PSZ-AC_8:8 | 0.89 | 0.89 | 0.48 | 0.48 | 0.8942 | 0.8908 | 0.8942 | 0.9962 | 1.0000 |
PSZ-AC_9:9 | 0.88 | 0.88 | 0.49 | 0.49 | 0.8816 | 0.8764 | 0.8816 | 0.9940 | 1.0000 |
PSZ-AC_10:10 | 0.88 | 0.88 | 0.57 | 0.57 | 0.8833 | 0.8696 | 0.8833 | 0.9845 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_1:1 | 28119.710 | 0.000 | 1.698710 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 28119.71 | 27155.67 | 1.698710 | 24.50 | 16.60 | 0.00868583 | 12.80 | 12.00 | 0.00850000 | 26.40 | 0.00838408 | 17.00 | 24.2215 | 23.89 | 0.00878241 | 47.0659 | 19077.58 | 0.00 | -999.00 | -999.00 |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_1:1 | 50934.818 | 50934.818 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 50934.82 | 50934.82 | 1.698712 | 9.61 | 6.66 | 0.00493475 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 24.2215 | 21.11 | 0.00681583 | 43.3909 | 17395.88 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_2:2 | 15559.140 | 0.000 | 0.939930 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15559.14 | 15055.05 | 0.939930 | 24.43 | 16.56 | 0.00867441 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 21.8874 | 23.89 | 0.00896786 | 48.0494 | 10358.51 | 0.00 | -999.00 | -999.00 |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_2:2 | 27379.571 | 27379.571 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27379.57 | 27379.57 | 0.939928 | 9.39 | 6.43 | 0.00483318 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 21.8875 | 21.11 | 0.00669580 | 42.6354 | 8530.65 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_3:3 | 15352.840 | 0.000 | 0.927470 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 15352.84 | 14854.55 | 0.927470 | 24.43 | 16.57 | 0.00867476 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 22.1815 | 23.89 | 0.00924018 | 49.4903 | 10316.70 | 0.00 | -999.00 | -999.00 |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_3:3 | 27234.118 | 27234.118 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27234.12 | 27234.12 | 0.927465 | 9.56 | 6.55 | 0.00486534 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.1816 | 21.11 | 0.00670571 | 42.6979 | 8654.95 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_4:4 | 15284.970 | 0.000 | 0.923370 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 15284.97 | 14789.65 | 0.923370 | 24.43 | 16.56 | 0.00867446 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 22.2800 | 23.89 | 0.00920908 | 49.3256 | 10352.21 | 0.00 | -999.00 | -999.00 |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_4:4 | 27093.006 | 27093.006 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27093.01 | 27093.01 | 0.923365 | 9.68 | 6.64 | 0.00488999 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.2801 | 21.11 | 0.00671388 | 42.7494 | 8750.82 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_5:5 | 15333.360 | 0.000 | 0.926290 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 15333.36 | 14835.28 | 0.926290 | 24.44 | 16.57 | 0.00867493 | 12.80 | 12.00 | 0.00850000 | 26.32 | 0.00838408 | 16.97 | 22.2098 | 23.89 | 0.00923311 | 49.4529 | 10296.83 | 0.00 | -999.00 | -999.00 |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_5:5 | 27207.496 | 27207.496 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27207.50 | 27207.50 | 0.926288 | 9.90 | 6.80 | 0.00493321 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.2098 | 21.11 | 0.00672877 | 42.8432 | 8921.49 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_6:6 | 27991.620 | 0.000 | 1.690970 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 27991.62 | 27020.65 | 1.690970 | 24.47 | 16.59 | 0.00868769 | 12.80 | 12.00 | 0.00850000 | 26.25 | 0.00838408 | 16.95 | 24.3324 | 23.89 | 0.00915086 | 49.0179 | 18817.63 | 0.00 | -999.00 | -999.00 |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_6:6 | 50056.323 | 50056.323 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 50056.32 | 50056.32 | 1.690974 | 9.52 | 6.59 | 0.00491961 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 24.3323 | 21.11 | 0.00681750 | 43.4013 | 17248.70 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_7:7 | 14921.050 | 0.000 | 0.901380 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14921.05 | 14422.76 | 0.901380 | 24.45 | 16.58 | 0.00868022 | 12.80 | 12.00 | 0.00850000 | 26.25 | 0.00838408 | 16.95 | 22.8235 | 23.89 | 0.00908218 | 48.6548 | 10429.62 | 0.00 | -999.00 | -999.00 |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_7:7 | 26582.346 | 26582.346 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26582.35 | 26582.35 | 0.901380 | 10.25 | 7.05 | 0.00500143 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 22.8235 | 21.11 | 0.00675157 | 42.9869 | 9204.31 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_8:8 | 14802.290 | 0.000 | 0.894210 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14802.29 | 14306.24 | 0.894210 | 24.46 | 16.58 | 0.00868093 | 12.80 | 12.00 | 0.00850000 | 26.25 | 0.00838408 | 16.95 | 23.0065 | 23.89 | 0.00910296 | 48.7648 | 10341.15 | 0.00 | -999.00 | -999.00 |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_8:8 | 26404.621 | 26404.621 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26404.62 | 26404.62 | 0.894206 | 10.24 | 7.05 | 0.00500103 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 23.0066 | 21.11 | 0.00675149 | 42.9864 | 9202.41 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_9:9 | 14594.330 | 0.000 | 0.881640 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14594.33 | 14103.19 | 0.881640 | 24.46 | 16.58 | 0.00868180 | 12.80 | 12.00 | 0.00850000 | 26.25 | 0.00838408 | 16.95 | 23.3345 | 23.89 | 0.00915175 | 49.0231 | 10178.73 | 0.00 | -999.00 | -999.00 |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_9:9 | 26078.353 | 26078.353 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26078.35 | 26078.35 | 0.881643 | 10.54 | 7.26 | 0.00506014 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 23.3345 | 21.11 | 0.00677155 | 43.1128 | 9458.48 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-AC_10:10 | 14621.820 | 0.000 | 0.883300 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14621.82 | 14127.46 | 0.883300 | 24.40 | 16.56 | 0.00868188 | 12.80 | 12.00 | 0.00850000 | 26.02 | 0.00838408 | 16.87 | 23.2907 | 23.89 | 0.00915957 | 49.0645 | 10103.21 | 0.00 | -999.00 | -999.00 |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-AC_10:10 | 25926.227 | 25926.227 | -999.0 | -999.0 | -999.000 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 25926.23 | 25926.23 | 0.883304 | 11.95 | 8.26 | 0.00534581 | 40.00 | 21.02 | 0.00800000 | -4.30 | 0.00265759 | -4.30 | 23.2906 | 21.11 | 0.00685968 | 43.6683 | 10921.84 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 28119.710 | 0.000 | 1.698710 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9865 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 14:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | 28119.71 | 27155.67 | 1.0000 | 2.02379555 | 1.698710 | 24.50 | 16.60 | 0.00868583 | 46734.4 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28119.71 | 26.40 | 0.00838408 | 17.00 | 0.41145340 | 24.2215 | 23.89 | 0.00878235 | 23.89 | 0.00878241 | 47.0659 | 19077.58 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_1:1 | LGSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 50934.818 | 50934.818 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.698712 | 2.02379763 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 50934.82 | 50934.82 | 1.0000 | 2.02379763 | 1.698712 | 9.61 | 6.66 | 0.00493475 | 22090.3 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 50934.82 | -4.30 | 0.00265759 | -4.30 | 0.41145340 | 24.2215 | 21.11 | 0.00681583 | 21.11 | 0.00681583 | 43.3909 | 17395.88 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15559.140 | 0.000 | 0.939930 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9653 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 15559.14 | 15055.05 | 1.0000 | 1.11980629 | 0.939930 | 24.43 | 16.56 | 0.00867441 | 46638.9 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15559.14 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 21.8874 | 23.89 | 0.00875781 | 23.89 | 0.00896786 | 48.0494 | 10358.51 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_2:2 | SMSTORE1 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27379.571 | 27379.571 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.939928 | 1.11980357 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27379.57 | 27379.57 | 1.0000 | 1.11980357 | 0.939928 | 9.39 | 6.43 | 0.00483318 | 21605.8 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27379.57 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 21.8875 | 21.11 | 0.00669580 | 21.11 | 0.00669580 | 42.6354 | 8530.65 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15352.840 | 0.000 | 0.927470 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9659 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 15352.84 | 14854.55 | 1.0000 | 1.10496180 | 0.927470 | 24.43 | 16.57 | 0.00867476 | 46642.1 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15352.84 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 22.1815 | 23.89 | 0.00875870 | 23.89 | 0.00924018 | 49.4903 | 10316.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_3:3 | SMSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27234.118 | 27234.118 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.927465 | 1.10495585 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27234.12 | 27234.12 | 1.0000 | 1.10495585 | 0.927465 | 9.56 | 6.55 | 0.00486534 | 21857.4 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27234.12 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 22.1816 | 21.11 | 0.00670571 | 21.11 | 0.00670571 | 42.6979 | 8654.95 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15284.970 | 0.000 | 0.923370 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9654 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:20:00 | 15284.97 | 14789.65 | 1.0000 | 1.10007717 | 0.923370 | 24.43 | 16.56 | 0.00867446 | 46639.4 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15284.97 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 22.2800 | 23.89 | 0.00875794 | 23.89 | 0.00920908 | 49.3256 | 10352.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_4:4 | SMSTORE3 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27093.006 | 27093.006 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.923365 | 1.10007124 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27093.01 | 27093.01 | 1.0000 | 1.10007124 | 0.923365 | 9.68 | 6.64 | 0.00488999 | 22047.8 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27093.01 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 22.2801 | 21.11 | 0.00671388 | 21.11 | 0.00671388 | 42.7494 | 8750.82 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 15333.360 | 0.000 | 0.926290 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9663 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:50:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 09:00:00 | 15333.36 | 14835.28 | 1.0000 | 1.10355598 | 0.926290 | 24.44 | 16.57 | 0.00867493 | 46643.6 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 15333.36 | 26.32 | 0.00838408 | 16.97 | 0.20572670 | 22.2098 | 23.89 | 0.00875913 | 23.89 | 0.00923311 | 49.4529 | 10296.83 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_5:5 | SMSTORE4 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 27207.496 | 27207.496 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.926288 | 1.10355361 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 27207.50 | 27207.50 | 1.0000 | 1.10355361 | 0.926288 | 9.90 | 6.80 | 0.00493321 | 22378.3 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27207.50 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 22.2098 | 21.11 | 0.00672877 | 21.11 | 0.00672877 | 42.8432 | 8921.49 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 27991.620 | 0.000 | 1.690970 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9900 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 27991.62 | 27020.65 | 1.0000 | 2.01457433 | 1.690970 | 24.47 | 16.59 | 0.00868769 | 46709.7 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 27991.62 | 26.25 | 0.00838408 | 16.95 | 0.41145340 | 24.3324 | 23.89 | 0.00878658 | 23.89 | 0.00915086 | 49.0179 | 18817.63 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_6:6 | LGSTORE2 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 50056.323 | 50056.323 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 1.690974 | 2.01457874 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 50056.32 | 50056.32 | 1.0000 | 2.01457874 | 1.690974 | 9.52 | 6.59 | 0.00491961 | 21952.8 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 50056.32 | -4.30 | 0.00265759 | -4.30 | 0.41145340 | 24.3323 | 21.11 | 0.00681750 | 21.11 | 0.00681750 | 43.4013 | 17248.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14921.050 | 0.000 | 0.901380 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9761 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14921.05 | 14422.76 | 1.0000 | 1.07387890 | 0.901380 | 24.45 | 16.58 | 0.00868022 | 46672.8 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14921.05 | 26.25 | 0.00838408 | 16.95 | 0.20572670 | 22.8235 | 23.89 | 0.00877286 | 23.89 | 0.00908218 | 48.6548 | 10429.62 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_7:7 | SMSTORE5 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26582.346 | 26582.346 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.901380 | 1.07387946 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26582.35 | 26582.35 | 1.0000 | 1.07387946 | 0.901380 | 10.25 | 7.05 | 0.00500143 | 22899.4 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26582.35 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 22.8235 | 21.11 | 0.00675157 | 21.11 | 0.00675157 | 42.9869 | 9204.31 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14802.290 | 0.000 | 0.894210 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9774 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14802.29 | 14306.24 | 1.0000 | 1.06533677 | 0.894210 | 24.46 | 16.58 | 0.00868093 | 46679.5 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14802.29 | 26.25 | 0.00838408 | 16.95 | 0.20572670 | 23.0065 | 23.89 | 0.00877483 | 23.89 | 0.00910296 | 48.7648 | 10341.15 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_8:8 | SMSTORE6 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26404.621 | 26404.621 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.894206 | 1.06533225 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26404.62 | 26404.62 | 1.0000 | 1.06533225 | 0.894206 | 10.24 | 7.05 | 0.00500103 | 22896.1 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26404.62 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 23.0066 | 21.11 | 0.00675149 | 21.11 | 0.00675149 | 42.9864 | 9202.41 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14594.330 | 0.000 | 0.881640 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9790 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:40:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14594.33 | 14103.19 | 1.0000 | 1.05036122 | 0.881640 | 24.46 | 16.58 | 0.00868180 | 46687.8 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14594.33 | 26.25 | 0.00838408 | 16.95 | 0.20572670 | 23.3345 | 23.89 | 0.00877727 | 23.89 | 0.00915175 | 49.0231 | 10178.73 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_9:9 | SMSTORE7 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 26078.353 | 26078.353 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.881643 | 1.05036505 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 26078.35 | 26078.35 | 1.0000 | 1.05036505 | 0.881643 | 10.54 | 7.26 | 0.00506014 | 23343.3 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 26078.35 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 23.3345 | 21.11 | 0.00677155 | 21.11 | 0.00677155 | 43.1128 | 9458.48 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 14621.820 | 0.000 | 0.883300 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1020.9792 | 1004.8586 | 1.1914 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 13:10:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | WILLIAM R FAIRCHILD ANN CLG .4% CONDNS DB=>MWB | 8/21 10:20:00 | 14621.82 | 14127.46 | 1.0000 | 1.05233890 | 0.883300 | 24.40 | 16.56 | 0.00868188 | 46629.1 | 12.80 | 12.00 | 0.00850000 | 34322.2 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14621.82 | 26.02 | 0.00838408 | 16.87 | 0.20572670 | 23.2907 | 23.89 | 0.00877680 | 23.89 | 0.00915957 | 49.0645 | 10103.21 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-AC_10:10 | SMSTORE8 | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25926.227 | 25926.227 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1914 | PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN | Fan:SystemModel | 0.883304 | 1.05234399 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | unknown | unknown | WILLIAM R FAIRCHILD ANN HTG 99.6% CONDNS DB | 1/21 13:00:00 | 25926.23 | 25926.23 | 1.0000 | 1.05234399 | 0.883304 | 11.95 | 8.26 | 0.00534581 | 25500.4 | 40.00 | 21.02 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25926.23 | -4.30 | 0.00265759 | -4.30 | 0.20572670 | 23.2906 | 21.11 | 0.00685968 | 21.11 | 0.00685968 | 43.6683 | 10921.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-AC_1:1_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.70 | - | |||
PSZ-AC_2:2_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.94 | - | |||
PSZ-AC_3:3_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.93 | - | |||
PSZ-AC_4:4_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.92 | - | |||
PSZ-AC_5:5_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.93 | - | |||
PSZ-AC_6:6_OA_CONTROLLER | DifferentialDryBulb | 0.41 | 1.69 | - | |||
PSZ-AC_7:7_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.90 | - | |||
PSZ-AC_8:8_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.89 | - | |||
PSZ-AC_9:9_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.88 | - | |||
PSZ-AC_10:10_OA_CONTROLLER | DifferentialDryBulb | 0.21 | 0.88 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
LGSTORE1 | 1508.33 | 3729.17 | 217.50 |
SMSTORE1 | 1439.83 | 3415.67 | 25.33 |
SMSTORE2 | 1119.83 | 2722.50 | 63.83 |
SMSTORE3 | 1124.33 | 2763.50 | 98.67 |
SMSTORE4 | 1113.50 | 2819.17 | 141.00 |
LGSTORE2 | 1005.67 | 2667.50 | 205.67 |
SMSTORE5 | 924.67 | 2703.33 | 227.33 |
SMSTORE6 | 912.50 | 2743.17 | 253.67 |
SMSTORE7 | 930.33 | 2862.33 | 346.83 |
SMSTORE8 | 1240.67 | 3107.00 | 798.83 |
Facility | 2433.33 | 4406.50 | 960.67 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
LGSTORE1 | 0.50 | 0.00 | 0.00 | 0.00 |
SMSTORE1 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE2 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE3 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE4 | 0.00 | 0.00 | 0.00 | 0.00 |
LGSTORE2 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE5 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE6 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE7 | 0.00 | 0.00 | 0.00 | 0.00 |
SMSTORE8 | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 0.50 | 0.00 | 0.00 | 0.00 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 1.059 | 0.223 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 1.020 | 0.242 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 1.173 | 0.317 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 1.163 | 0.317 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 1.147 | 0.317 | 0.000 | 0.000 |
LGSTORE2 | 13.21 | 30.00 | 1805.20 | 1.092 | 0.305 | 0.000 | 0.000 |
SMSTORE5 | 6.60 | 15.00 | 902.60 | 1.111 | 0.339 | 0.000 | 0.000 |
SMSTORE6 | 6.60 | 15.00 | 902.60 | 1.098 | 0.339 | 0.000 | 0.000 |
SMSTORE7 | 6.60 | 15.00 | 902.60 | 1.070 | 0.339 | 0.000 | 0.000 |
SMSTORE8 | 6.60 | 15.00 | 902.60 | 1.030 | 0.350 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
LGSTORE1 | 9.03 | 30.00 | 1805.20 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE1 | 4.51 | 15.00 | 902.60 | 0.000 | 0.000 | 0.000 | 0.000 |
SMSTORE2 | 3.78 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE3 | 3.78 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE4 | 3.78 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
LGSTORE2 | 13.21 | 30.00 | 1805.20 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE5 | 6.60 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE6 | 6.60 | 15.00 | 902.60 | 0.806 | 0.000 | 0.000 | 0.000 |
SMSTORE7 | 6.60 | 15.00 | 902.60 | 0.805 | 0.000 | 0.000 | 0.000 |
SMSTORE8 | 6.60 | 15.00 | 902.60 | 0.802 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Surfaces by ClassTotal | Outdoors | |
Wall | 40 | 22 |
Floor | 10 | 10 |
Roof | 10 | 10 |
Internal Mass | 10 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 36 | 36 |
Door | 12 | 12 |
Glass Door | 12 | 12 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 10 |
Conditioned Zones | 10 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
Electricity:Building | 715.79 | 2374.76 | 01-JAN-00:10 | 44671.08 | 01-JAN-11:10 |
Electricity:Zone:LGSTORE1 | 161.97 | 442.08 | 01-JAN-00:10 | 8324.52 | 01-JAN-10:10 |
InteriorLights:Electricity | 587.07 | 1925.34 | 01-JAN-00:10 | 36581.55 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE1 | 135.61 | 367.17 | 01-JAN-00:10 | 6976.27 | 01-JAN-10:10 |
LightsWired:InteriorLights:Electricity | 587.07 | 1925.34 | 01-JAN-00:10 | 36581.55 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE1 | 85.62 | 233.60 | 01-JAN-00:10 | 4400.95 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE1 | 72.45 | 196.15 | 01-JAN-00:10 | 3726.82 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE2 | 62.39 | 214.85 | 01-JAN-00:10 | 4044.70 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE2 | 51.92 | 177.40 | 01-JAN-00:10 | 3370.57 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE3 | 62.39 | 214.85 | 01-JAN-00:10 | 4044.70 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE3 | 51.92 | 177.40 | 01-JAN-00:10 | 3370.57 | 01-JAN-10:10 |
Electricity:Zone:SMSTORE4 | 62.39 | 214.85 | 01-JAN-00:10 | 4044.70 | 01-JAN-10:10 |
InteriorLights:Electricity:Zone:SMSTORE4 | 51.92 | 177.40 | 01-JAN-00:10 | 3370.57 | 01-JAN-10:10 |
Electricity:Zone:LGSTORE2 | 93.68 | 351.51 | 01-JAN-00:10 | 6603.84 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:LGSTORE2 | 74.42 | 276.61 | 01-JAN-00:10 | 5255.58 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE5 | 46.84 | 175.76 | 01-JAN-00:10 | 3301.92 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE5 | 37.21 | 138.30 | 01-JAN-00:10 | 2627.79 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE6 | 46.84 | 175.76 | 01-JAN-00:10 | 3301.92 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE6 | 37.21 | 138.30 | 01-JAN-00:10 | 2627.79 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE7 | 46.84 | 175.76 | 01-JAN-00:10 | 3301.92 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE7 | 37.21 | 138.30 | 01-JAN-00:10 | 2627.79 | 01-JAN-11:10 |
Electricity:Zone:SMSTORE8 | 46.84 | 175.76 | 01-JAN-00:10 | 3301.92 | 01-JAN-11:10 |
InteriorLights:Electricity:Zone:SMSTORE8 | 37.21 | 138.30 | 01-JAN-00:10 | 2627.79 | 01-JAN-11:10 |
InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:LGSTORE1 | 26.36 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-10:10 |
MiscPlug:InteriorEquipment:Electricity | 128.72 | 449.42 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE1 | 13.18 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE2 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE3 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:SMSTORE4 | 10.47 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-10:10 |
InteriorEquipment:Electricity:Zone:LGSTORE2 | 19.26 | 74.90 | 01-JAN-00:10 | 1348.26 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE5 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE6 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE7 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
InteriorEquipment:Electricity:Zone:SMSTORE8 | 9.63 | 37.45 | 01-JAN-00:10 | 674.13 | 01-JAN-11:10 |
Electricity:Plant | 65.13 | 1218.00 | 06-JAN-09:10 | 11867.03 | 12-JAN-13:50 |
WaterSystems:Electricity | 65.13 | 1218.00 | 06-JAN-09:10 | 11867.03 | 12-JAN-13:50 |
Water Heater:WaterSystems:Electricity | 65.13 | 1218.00 | 06-JAN-09:10 | 11867.03 | 12-JAN-13:50 |
ElectricityPurchased:Facility | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
ElectricityPurchased:Plant | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
Cogeneration:ElectricityPurchased | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
ElectricityNet:Plant | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
Cogeneration:ElectricityNet | 1106.02 | 3592.76 | 29-JAN-08:00 | 88480.21 | 22-JUL-15:50 |
Electricity:HVAC | 214.57 | 0.00 | 01-JAN-00:10 | 38478.40 | 22-JUL-15:00 |
Fans:Electricity | 201.35 | 0.00 | 01-JAN-00:10 | 11684.56 | 05-JAN-16:20 |
General:Fans:Electricity | 201.35 | 0.00 | 01-JAN-00:10 | 11684.56 | 05-JAN-16:20 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 13.21 | 0.00 | 01-JAN-00:10 | 26793.84 | 22-JUL-15:00 |
ExteriorLights:Electricity | 110.53 | 0.00 | 01-JAN-08:20 | 7048.38 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 110.53 | 0.00 | 01-JAN-08:20 | 7048.38 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 263.99 | 0.00 | 01-JAN-00:10 | 149961.26 | 10-JAN-09:10 |
Gas:HVAC | 263.99 | 0.00 | 01-JAN-00:10 | 149961.26 | 10-JAN-09:10 |
Heating:Gas | 263.99 | 0.00 | 01-JAN-00:10 | 149961.26 | 10-JAN-09:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:Water | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Facility | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
MainsWater:Plant | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Water Heater:WaterSystems:MainsWater | 87.30 | 0.00 | 01-JAN-00:10 | 0.00 | 06-JAN-13:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 626.76 | 0.00 | 01-JAN-00:10 | 186163.66 | 10-JAN-09:10 |
EnergyTransfer:Building | 364.44 | 0.00 | 01-JAN-00:10 | 73765.48 | 22-JUL-15:00 |
EnergyTransfer:Zone:LGSTORE1 | 84.60 | 0.00 | 01-JAN-00:10 | 13549.57 | 31-DEC-09:10 |
Heating:EnergyTransfer | 49.43 | 0.00 | 01-JAN-00:10 | 61248.30 | 10-JAN-09:10 |
Heating:EnergyTransfer:Zone:LGSTORE1 | 4.91 | 0.00 | 01-JAN-00:10 | 10895.73 | 10-JAN-09:10 |
Cooling:EnergyTransfer | 315.01 | 0.00 | 01-JAN-00:10 | 73765.48 | 22-JUL-15:00 |
Cooling:EnergyTransfer:Zone:LGSTORE1 | 79.68 | 0.00 | 01-JAN-00:10 | 12908.80 | 22-JUL-16:20 |
EnergyTransfer:Zone:SMSTORE1 | 44.10 | 0.00 | 01-JAN-00:10 | 9666.23 | 04-SEP-17:20 |
Heating:EnergyTransfer:Zone:SMSTORE1 | 1.65 | 0.00 | 01-JAN-00:10 | 3307.74 | 10-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE1 | 42.46 | 0.00 | 01-JAN-00:10 | 9666.23 | 04-SEP-17:20 |
EnergyTransfer:Zone:SMSTORE2 | 32.39 | 0.00 | 01-JAN-00:10 | 6643.49 | 23-JUL-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE2 | 2.46 | 0.00 | 01-JAN-00:10 | 4889.76 | 10-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE2 | 29.93 | 0.00 | 01-JAN-00:10 | 6636.86 | 23-JUL-08:10 |
EnergyTransfer:Zone:SMSTORE3 | 31.22 | 0.00 | 01-JAN-00:10 | 7283.91 | 31-DEC-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE3 | 2.90 | 0.00 | 01-JAN-00:10 | 5757.40 | 10-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE3 | 28.32 | 0.00 | 01-JAN-00:10 | 6793.90 | 23-JUL-08:10 |
EnergyTransfer:Zone:SMSTORE4 | 29.55 | 0.00 | 01-JAN-00:10 | 7166.68 | 18-DEC-08:10 |
Heating:EnergyTransfer:Zone:SMSTORE4 | 3.46 | 0.00 | 01-JAN-00:10 | 5991.33 | 10-JAN-08:10 |
Cooling:EnergyTransfer:Zone:SMSTORE4 | 26.09 | 0.00 | 01-JAN-00:10 | 6444.32 | 23-JUL-08:10 |
EnergyTransfer:Zone:LGSTORE2 | 48.10 | 0.00 | 01-JAN-00:10 | 15374.30 | 30-DEC-09:10 |
Heating:EnergyTransfer:Zone:LGSTORE2 | 7.49 | 0.00 | 01-JAN-00:10 | 13178.93 | 30-DEC-09:10 |
Cooling:EnergyTransfer:Zone:LGSTORE2 | 40.61 | 0.00 | 01-JAN-00:10 | 12677.27 | 23-JUL-09:10 |
EnergyTransfer:Zone:SMSTORE5 | 24.29 | 0.00 | 01-JAN-00:10 | 7958.23 | 09-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE5 | 4.63 | 0.00 | 01-JAN-00:10 | 7033.12 | 09-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE5 | 19.67 | 0.00 | 01-JAN-00:10 | 6252.91 | 23-JUL-09:10 |
EnergyTransfer:Zone:SMSTORE6 | 23.77 | 0.00 | 01-JAN-00:10 | 8290.09 | 30-DEC-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE6 | 4.94 | 0.00 | 01-JAN-00:10 | 7213.28 | 30-DEC-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE6 | 18.83 | 0.00 | 01-JAN-00:10 | 6062.12 | 23-JUL-09:10 |
EnergyTransfer:Zone:SMSTORE7 | 22.77 | 0.00 | 01-JAN-00:10 | 8198.68 | 04-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE7 | 6.08 | 0.00 | 01-JAN-00:10 | 7710.69 | 10-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE7 | 16.69 | 0.00 | 01-JAN-00:10 | 5859.79 | 22-JUL-15:00 |
EnergyTransfer:Zone:SMSTORE8 | 23.65 | 0.00 | 01-JAN-00:10 | 11152.03 | 10-JAN-09:10 |
Heating:EnergyTransfer:Zone:SMSTORE8 | 10.92 | 0.00 | 01-JAN-00:10 | 10498.18 | 10-JAN-09:10 |
Cooling:EnergyTransfer:Zone:SMSTORE8 | 12.73 | 0.00 | 01-JAN-00:10 | 5783.86 | 22-JUL-15:00 |
EnergyTransfer:HVAC | 262.31 | 0.00 | 01-JAN-00:10 | 119969.00 | 10-JAN-09:10 |
HeatingCoils:EnergyTransfer | 211.19 | 0.00 | 01-JAN-00:10 | 119969.00 | 10-JAN-09:10 |
CoolingCoils:EnergyTransfer | 51.12 | 0.00 | 01-JAN-00:10 | 100744.75 | 22-JUL-15:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
LGSTORE1 | 0.000 | 0.000 | 4.911 | -79.685 | 0.000 | 0.000 | 13.540 | 135.611 | 26.357 | 16.685 | 0.000 | 0.065 | 0.001 | 0.000 | -11.094 | 0.000 | -34.079 | -72.311 |
SMSTORE1 | 0.000 | 0.000 | 1.646 | -42.457 | 0.000 | 0.000 | 6.622 | 72.445 | 13.179 | 8.256 | 0.000 | 0.035 | 0.001 | 0.000 | -5.821 | 0.000 | -17.836 | -36.070 |
SMSTORE2 | 0.000 | 0.000 | 2.459 | -29.927 | 0.000 | 0.000 | 4.062 | 51.921 | 10.467 | 8.269 | 0.000 | 0.035 | 0.001 | 0.000 | -5.704 | 0.000 | -18.040 | -23.542 |
SMSTORE3 | 0.000 | 0.000 | 2.896 | -28.324 | 0.000 | 0.000 | 4.072 | 51.921 | 10.467 | 8.288 | 0.000 | 0.035 | 0.000 | 0.000 | -5.629 | 0.000 | -17.955 | -25.772 |
SMSTORE4 | 0.000 | 0.000 | 3.457 | -26.091 | 0.000 | 0.000 | 4.082 | 51.921 | 10.467 | 8.310 | 0.000 | 0.035 | 0.001 | 0.000 | -5.568 | 0.000 | -17.868 | -28.745 |
LGSTORE2 | 0.000 | 0.000 | 7.491 | -40.614 | 0.000 | 0.000 | 14.057 | 74.416 | 19.261 | 16.712 | 0.000 | 0.063 | 0.000 | 0.000 | -10.869 | 0.000 | -32.311 | -48.206 |
SMSTORE5 | 0.000 | 0.000 | 4.629 | -19.665 | 0.000 | 0.000 | 7.031 | 37.208 | 9.631 | 8.352 | 0.000 | 0.035 | 0.000 | 0.000 | -5.430 | 0.000 | -17.769 | -24.021 |
SMSTORE6 | 0.000 | 0.000 | 4.941 | -18.829 | 0.000 | 0.000 | 7.040 | 37.208 | 9.631 | 8.367 | 0.000 | 0.035 | 0.000 | 0.000 | -5.398 | 0.000 | -17.722 | -25.272 |
SMSTORE7 | 0.000 | 0.000 | 6.080 | -16.692 | 0.000 | 0.000 | 7.062 | 37.208 | 9.631 | 8.403 | 0.000 | 0.035 | 0.001 | 0.000 | -5.307 | 0.000 | -17.597 | -28.823 |
SMSTORE8 | 0.000 | 0.000 | 10.920 | -12.730 | 0.000 | 0.000 | 7.102 | 37.208 | 9.631 | 8.499 | 0.000 | 0.036 | 0.000 | 0.000 | -5.004 | 0.000 | -20.021 | -35.640 |
Total Facility | 0.000 | 0.000 | 49.429 | -315.013 | 0.000 | 0.000 | 74.671 | 587.066 | 128.721 | 100.141 | 0.000 | 0.409 | 0.005 | 0.000 | -65.824 | 0.000 | -211.197 | -348.401 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 22-AUG-08:62 | 0.00 | 0.00 | 0.00 | -33225.56 | 0.00 | 0.00 | 97.58 | 3671.72 | 749.03 | 125.79 | 0.00 | 0.00 | 29005.72 | 0.00 | -0.00 | 0.00 | -424.28 | 0.00 |
SMSTORE1 | 22-AUG-08:62 | 0.00 | 0.00 | 0.00 | -18750.76 | 0.00 | 0.00 | 47.00 | 1961.49 | 374.52 | 54.39 | 0.00 | 0.00 | 16527.22 | 0.00 | -0.00 | 0.00 | -213.85 | 0.00 |
SMSTORE2 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | -24238.84 | 0.00 | 0.00 | 48.76 | 1773.99 | 374.52 | 0.00 | 0.00 | 0.00 | 22624.15 | 0.00 | -128.61 | 0.00 | -453.97 | 0.00 |
SMSTORE3 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | -24111.74 | 0.00 | 0.00 | 48.87 | 1773.99 | 374.52 | 0.00 | 0.00 | 0.00 | 22495.83 | 0.00 | -128.12 | 0.00 | -453.34 | 0.00 |
SMSTORE4 | 01-MAY-07:01 | 0.00 | 0.00 | 0.00 | -22273.28 | 0.00 | 0.00 | 49.40 | 1773.99 | 374.52 | 0.00 | 0.00 | 0.00 | 20652.24 | 0.00 | -125.59 | 0.00 | -451.28 | 0.00 |
LGSTORE2 | 22-AUG-08:62 | 0.00 | 0.00 | 0.00 | -33304.06 | 0.00 | 0.00 | 213.72 | 2766.09 | 749.03 | 120.00 | 0.00 | 0.00 | 29831.67 | 0.00 | -0.00 | 0.00 | -376.45 | 0.00 |
SMSTORE5 | 25-JUN-09:02 | 0.00 | 0.00 | 0.00 | -16863.10 | 0.00 | 0.00 | 104.06 | 1383.05 | 374.52 | 439.89 | 0.00 | 0.00 | 14746.65 | 0.00 | -0.00 | 0.00 | -185.06 | 0.00 |
SMSTORE6 | 25-JUN-09:02 | 0.00 | 0.00 | 0.00 | -16654.77 | 0.00 | 0.00 | 104.84 | 1383.05 | 374.52 | 441.53 | 0.00 | 0.00 | 14534.01 | 0.00 | -0.00 | 0.00 | -183.17 | 0.00 |
SMSTORE7 | 25-JUN-09:02 | 0.00 | 0.00 | 0.00 | -16176.87 | 0.00 | 0.00 | 107.28 | 1383.05 | 374.52 | 446.27 | 0.00 | 0.00 | 14042.66 | 0.00 | -0.00 | 0.00 | -176.90 | 0.00 |
SMSTORE8 | 24-JUL-08:62 | 0.00 | 0.00 | 0.00 | -14875.69 | 0.00 | 0.00 | 109.05 | 1383.05 | 374.52 | 263.60 | 0.00 | 0.00 | 12994.04 | 0.00 | -0.00 | 0.00 | -248.56 | 0.00 |
Total Facility | 24-JUL-08:62 | 0.00 | 0.00 | 0.00 | -148097.32 | 0.00 | 0.00 | 1068.47 | 24043.21 | 5393.02 | 3039.51 | 0.00 | 0.00 | 117392.17 | 0.00 | 0.00 | 0.00 | -2839.06 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
LGSTORE1 | 04-MAR-09:01 | 0.00 | 0.00 | 43257.46 | 0.00 | 0.00 | 0.00 | 128.21 | 3671.72 | 749.03 | 298.98 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -770.61 | -47334.79 |
SMSTORE1 | 10-JAN-09:01 | 0.00 | 0.00 | 18965.00 | 0.00 | 0.00 | 0.00 | 63.78 | 1961.49 | 374.52 | 945.83 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -631.42 | -21679.19 |
SMSTORE2 | 31-DEC-09:02 | 0.00 | 0.00 | 16935.10 | 0.00 | 0.00 | 0.00 | 64.65 | 1773.99 | 374.52 | 325.54 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -496.97 | -18976.83 |
SMSTORE3 | 31-DEC-09:02 | 0.00 | 0.00 | 21916.93 | 0.00 | 0.00 | 0.00 | 65.53 | 1773.99 | 374.52 | 331.49 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -496.50 | -23965.96 |
SMSTORE4 | 02-JAN-08:61 | 0.00 | 0.00 | 22616.65 | 0.00 | 0.00 | 0.00 | 64.58 | 1773.99 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -335.82 | 0.00 | -454.73 | -24039.18 |
LGSTORE2 | 04-DEC-09:01 | 0.00 | 0.00 | 44612.21 | 0.00 | 0.00 | 0.00 | 291.39 | 2766.09 | 749.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -352.59 | 0.00 | -543.89 | -47522.24 |
SMSTORE5 | 04-DEC-09:01 | 0.00 | 0.00 | 23853.11 | 0.00 | 0.00 | 0.00 | 145.84 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -176.69 | 0.00 | -300.18 | -25279.64 |
SMSTORE6 | 04-DEC-09:01 | 0.00 | 0.00 | 23709.45 | 0.00 | 0.00 | 0.00 | 146.55 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -174.57 | 0.00 | -297.20 | -25141.80 |
SMSTORE7 | 04-DEC-09:01 | 0.00 | 0.00 | 23494.08 | 0.00 | 0.00 | 0.00 | 149.06 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -167.37 | 0.00 | -286.78 | -24946.55 |
SMSTORE8 | 02-JAN-08:61 | 0.00 | 0.00 | 25937.42 | 0.00 | 0.00 | 0.00 | 0.00 | 138.30 | 37.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -296.95 | 0.00 | -388.30 | -25427.93 |
Total Facility | 30-DEC-09:01 | 0.00 | 0.00 | 186458.03 | 0.00 | 0.00 | 0.00 | 1462.08 | 24043.21 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3904.41 | 0.00 | -5907.32 | -207544.61 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.6987 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.6987 | 0.2422 | 1.0000 | 0.4115 | 0.2422 | ||
PSZ-AC_2:2 | 0.9339 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9399 | 0.2189 | 1.0000 | 0.2057 | 0.2189 | ||
PSZ-AC_3:3 | 0.9275 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9275 | 0.2218 | 1.0000 | 0.2057 | 0.2218 | ||
PSZ-AC_4:4 | 0.9212 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9234 | 0.2228 | 1.0000 | 0.2057 | 0.2228 | ||
PSZ-AC_5:5 | 0.9263 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9263 | 0.2221 | 1.0000 | 0.2057 | 0.2221 | ||
PSZ-AC_6:6 | 1.6599 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.6910 | 0.2433 | 1.0000 | 0.4115 | 0.2433 | ||
PSZ-AC_7:7 | 0.8986 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9014 | 0.2282 | 1.0000 | 0.2057 | 0.2282 | ||
PSZ-AC_8:8 | 0.8908 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8942 | 0.2301 | 1.0000 | 0.2057 | 0.2301 | ||
PSZ-AC_9:9 | 0.8764 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8816 | 0.2333 | 1.0000 | 0.2057 | 0.2333 | ||
PSZ-AC_10:10 | 0.8696 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8833 | 0.2329 | 1.0000 | 0.2057 | 0.2329 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-AC_1:1 | 1.6987 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.6987 | 1.0000 | 1.0000 | 0.4115 | 0.2422 | ||
PSZ-AC_2:2 | 0.9339 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9339 | 1.0000 | 1.0000 | 0.2057 | 0.2203 | ||
PSZ-AC_3:3 | 0.9275 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9275 | 1.0000 | 1.0000 | 0.2057 | 0.2218 | ||
PSZ-AC_4:4 | 0.9212 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9212 | 1.0000 | 1.0000 | 0.2057 | 0.2233 | ||
PSZ-AC_5:5 | 0.9263 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.9263 | 1.0000 | 1.0000 | 0.2057 | 0.2221 | ||
PSZ-AC_6:6 | 1.6599 | 0.0000 | 29.9961 | 1.0000 | 0.4115 | 1.6599 | 1.0000 | 1.0000 | 0.4115 | 0.2479 | ||
PSZ-AC_7:7 | 0.8986 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8986 | 1.0000 | 1.0000 | 0.2057 | 0.2289 | ||
PSZ-AC_8:8 | 0.8908 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8908 | 1.0000 | 1.0000 | 0.2057 | 0.2309 | ||
PSZ-AC_9:9 | 0.8764 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8764 | 1.0000 | 1.0000 | 0.2057 | 0.2348 | ||
PSZ-AC_10:10 | 0.8696 | 0.0000 | 14.9980 | 1.0000 | 0.2057 | 0.8696 | 1.0000 | 1.0000 | 0.2057 | 0.2366 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
LGSTORE1 | PSZ-AC_1:1 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE1 | PSZ-AC_2:2 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE2 | PSZ-AC_3:3 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE3 | PSZ-AC_4:4 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE4 | PSZ-AC_5:5 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
LGSTORE2 | PSZ-AC_6:6 | 0.000000 | 29.9961 | 0.001181 | 348.39 | 0.4115 | 1.0000 | 0.4115 | 1.000 | 0.4115 |
SMSTORE5 | PSZ-AC_7:7 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE6 | PSZ-AC_8:8 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE7 | PSZ-AC_9:9 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
SMSTORE8 | PSZ-AC_10:10 | 0.000000 | 14.9980 | 0.001181 | 174.19 | 0.2057 | 1.0000 | 0.2057 | 1.000 | 0.2057 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-AC_1:1 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_2:2 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_3:3 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_4:4 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_5:5 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_6:6 | 0.000000 | 30.00 | 0.001181 | 348.3864 | 0.4115 | 0.4115 | 0.4115 |
PSZ-AC_7:7 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_8:8 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_9:9 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
PSZ-AC_10:10 | 0.000000 | 15.00 | 0.001181 | 174.1932 | 0.2057 | 0.2057 | 0.2057 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.6987 | 1.6987 | 1.6987 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 0.9339 | 0.9339 | 0.9339 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 0.9275 | 0.9275 | 0.9275 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 0.9212 | 0.9212 | 0.9212 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 0.9263 | 0.9263 | 0.9263 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.6599 | 1.6599 | 1.6599 | 0.4115 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.8986 | 0.8986 | 0.8986 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.8908 | 0.8908 | 0.8908 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.8764 | 0.8764 | 0.8764 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 0.8696 | 0.8696 | 0.8696 | 0.2057 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.6987 | 1.6987 | 1.6987 | 1.6987 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 0.9339 | 0.9399 | 0.9339 | 0.9339 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 0.9275 | 0.9275 | 0.9275 | 0.9275 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 0.9212 | 0.9234 | 0.9212 | 0.9212 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 0.9263 | 0.9263 | 0.9263 | 0.9263 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.6599 | 1.6910 | 1.6599 | 1.6599 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.8986 | 0.9014 | 0.8986 | 0.8986 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.8908 | 0.8942 | 0.8908 | 0.8908 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.8764 | 0.8816 | 0.8764 | 0.8764 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 0.8696 | 0.8833 | 0.8696 | 0.8696 | 0.2057 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
LGSTORE1 | PSZ-AC_1:1 | 1.6987 | 1.6987 | 1.6987 | 0.4115 | 0.4524 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE1 | PSZ-AC_2:2 | 0.9339 | 0.9339 | 0.9339 | 0.2057 | 0.4612 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE2 | PSZ-AC_3:3 | 0.9275 | 0.9275 | 0.9275 | 0.2057 | 0.4546 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE3 | PSZ-AC_4:4 | 0.9212 | 0.9212 | 0.9212 | 0.2057 | 0.4496 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE4 | PSZ-AC_5:5 | 0.9263 | 0.9263 | 0.9263 | 0.2057 | 0.4410 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
LGSTORE2 | PSZ-AC_6:6 | 1.6599 | 1.6599 | 1.6599 | 0.4115 | 0.4562 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE5 | PSZ-AC_7:7 | 0.8986 | 0.8986 | 0.8986 | 0.2057 | 0.4275 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE6 | PSZ-AC_8:8 | 0.8908 | 0.8908 | 0.8908 | 0.2057 | 0.4276 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE7 | PSZ-AC_9:9 | 0.8764 | 0.8764 | 0.8764 | 0.2057 | 0.4160 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
SMSTORE8 | PSZ-AC_10:10 | 0.8696 | 0.8696 | 0.8696 | 0.2057 | 0.3603 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-AC_1:1 | 1.6987 | 1.6987 | 1.6987 | 1.6987 | 0.4115 | 1.0000 |
PSZ-AC_2:2 | 0.9339 | 0.9339 | 0.9339 | 0.9339 | 0.2057 | 1.0000 |
PSZ-AC_3:3 | 0.9275 | 0.9275 | 0.9275 | 0.9275 | 0.2057 | 1.0000 |
PSZ-AC_4:4 | 0.9212 | 0.9212 | 0.9212 | 0.9212 | 0.2057 | 1.0000 |
PSZ-AC_5:5 | 0.9263 | 0.9263 | 0.9263 | 0.9263 | 0.2057 | 1.0000 |
PSZ-AC_6:6 | 1.6599 | 1.6599 | 1.6599 | 1.6599 | 0.4115 | 1.0000 |
PSZ-AC_7:7 | 0.8986 | 0.8986 | 0.8986 | 0.8986 | 0.2057 | 1.0000 |
PSZ-AC_8:8 | 0.8908 | 0.8908 | 0.8908 | 0.8908 | 0.2057 | 1.0000 |
PSZ-AC_9:9 | 0.8764 | 0.8764 | 0.8764 | 0.8764 | 0.2057 | 1.0000 |
PSZ-AC_10:10 | 0.8696 | 0.8696 | 0.8696 | 0.8696 | 0.2057 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:19:03
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** William R Fairchild WA USA TMY3 WMO#=727885 |
Total gross floor area [m2] | 2090.32 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
LGSTORE1 | 348.39 | 348.39 | 0.00 | 112.00 |
SMSTORE1 | 174.19 | 174.19 | 0.00 | 112.00 |
SMSTORE2 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE3 | 174.19 | 174.19 | 0.00 | 84.29 |
SMSTORE4 | 174.19 | 174.19 | 0.00 | 84.29 |
LGSTORE2 | 348.39 | 348.39 | 0.00 | 77.29 |
SMSTORE5 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE6 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE7 | 174.19 | 174.19 | 0.00 | 77.29 |
SMSTORE8 | 174.19 | 174.19 | 0.00 | 77.29 |
Totals | 2090.32 | 2090.32 | 0.00 |
Data | |
Number of hours heating loads not met | 0.00 |
Number of hours cooling loads not met | 0.00 |
Number of hours not met | 0.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 263.99 | 149961.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 13.21 | 26793.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 587.07 | 36581.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 110.53 | 7048.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 128.72 | 8089.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 201.35 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 65.13 | 11867.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 128.72 | 1106.02 |
Natural Gas | 0.00 | 263.99 |
Additional | 0.00 | 0.00 |
Total | 128.72 | 1370.01 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 280.85 |
Space Heating | 0.00 |
Space Cooling | 6.32 |
Fans (All) | 96.33 |
Service Water Heating | 31.16 |
Receptacle Equipment | 61.58 |
Miscellaneous (All) | 529.11 |
Subtotal | 529.11 |
Natural Gas [MJ/m2] | |
Space Heating | 126.29 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 126.29 |
Subtotal | 126.29 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 42.85 |
Space Heating | 19.27 |
Space Cooling | 0.96 |
Fans (All) | 14.70 |
Service Water Heating | 4.75 |
Receptacle Equipment | 9.40 |
Miscellaneous | 8.07 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
TYPE1_OCC_SCH | 1630. | 5840. |
TYPE2_OCC_SCH | 995. | 4429. |
TYPE3_OCC_SCH | 1709. | 4064. |
TYPE1_LIGHT_SCH | 5131. | 8760. |
TYPE2_LIGHT_SCH | 4096. | 8760. |
TYPE3_LIGHT_SCH | 3767. | 8760. |
TYPE1_EQUIP_SCH | 4888. | 8760. |
TYPE2_EQUIP_SCH | 3911. | 8760. |
TYPE3_EQUIP_SCH | 3600. | 8760. |
TYPE1_INFIL_SCH | 4302. | 8760. |
TYPE2_INFIL_SCH | 5164. | 8760. |
TYPE3_INFIL_SCH | 5438. | 8760. |
INFIL_DOOR_OPENING_SCH | 2477. | 4380. |
TYPE1_MINOA_MOTORIZEDDAMPER_SCH | 5579. | 5579. |
TYPE2_MINOA_MOTORIZEDDAMPER_SCH | 4429. | 4429. |
TYPE3_MINOA_MOTORIZEDDAMPER_SCH | 4064. | 4064. |
TYPE1_SWH_SCH | 2063. | 6048. |
TYPE2_SWH_SCH | 1831. | 4429. |
TYPE3_SWH_SCH | 1733. | 4064. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 7118. | 8760. |
MINOA_SCHED | 8760. | 8760. |
WORK_EFF_SCH | 0. | 0. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 5839. | 5839. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 7300. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
TYPE1_HTGSETP_SCH_YES_OPTIMUM | LGSTORE1 DUALSPSCHED | January | 21.11 | 365 | 21.11 | 365 |
TYPE1_CLGSETP_SCH_YES_OPTIMUM | LGSTORE1 DUALSPSCHED | July | 23.89 | 365 | 23.89 | 365 |
TYPE2_HTGSETP_SCH_YES_OPTIMUM | SMSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE2_CLGSETP_SCH_YES_OPTIMUM | SMSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
TYPE3_HTGSETP_SCH_YES_OPTIMUM | LGSTORE2 DUALSPSCHED | January | 21.11 | 365 | 15.56 | 365 |
TYPE3_CLGSETP_SCH_YES_OPTIMUM | LGSTORE2 DUALSPSCHED | July | 23.89 | 365 | 29.44 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2012
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME RETAILSTRIPMALL
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5C
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_PORTANGELES
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.602362E+11 |
February | 0.000 | 0.474558E+11 |
March | 0.000 | 0.407278E+11 |
April | 0.000 | 0.598887E+10 |
May | 0.000 | 0.252617E+10 |
June | 0.000 | 0.338697E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.671854E+10 |
November | 0.000 | 0.339520E+11 |
December | 0.000 | 0.663506E+11 |
Annual Sum or Average | 0.263990E+12 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.663506E+11 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.330476E+10 | 10844.33 | 10-JAN-09:04 | -3.8 | -5.3 | 0.568307E+09 | 688.62 | 29-JAN-18:00 | 9.00 | 8.43 |
February | 0.309185E+10 | 8676.14 | 17-FEB-00:12 | -1.3 | -1.3 | 0.512756E+09 | 680.12 | 04-FEB-13:09 | 9.00 | 6.12 |
March | 0.384626E+10 | 8128.54 | 15-MAR-08:02 | 2.00 | 1.57 | 0.565169E+09 | 734.00 | 19-MAR-17:00 | 11.00 | 10.48 |
April | 0.726214E+10 | 13625.46 | 29-APR-08:62 | 15.17 | 11.11 | 0.635288E+09 | 899.06 | 30-APR-12:09 | 22.00 | 13.84 |
May | 0.766161E+10 | 21734.38 | 23-MAY-08:62 | 17.33 | 14.09 | 0.674356E+09 | 899.04 | 21-MAY-17:10 | 20.00 | 12.84 |
June | 0.896028E+10 | 32127.49 | 24-JUN-08:62 | 14.00 | 11.82 | 0.716683E+09 | 899.09 | 25-JUN-17:00 | 22.00 | 19.93 |
July | 0.108903E+11 | 32079.30 | 27-JUL-08:62 | 13.17 | 11.94 | 0.752994E+09 | 899.04 | 16-JUL-16:49 | 18.33 | 15.09 |
August | 0.111991E+11 | 33231.99 | 22-AUG-08:62 | 16.00 | 10.46 | 0.743377E+09 | 899.05 | 20-AUG-17:10 | 21.17 | 14.67 |
September | 0.963080E+10 | 31051.58 | 02-SEP-08:62 | 13.33 | 12.58 | 0.726368E+09 | 899.05 | 24-SEP-16:10 | 21.83 | 15.33 |
October | 0.687223E+10 | 8107.74 | 01-OCT-17:02 | 11.83 | 8.81 | 0.652013E+09 | 898.99 | 08-OCT-17:19 | 12.67 | 12.11 |
November | 0.440778E+10 | 8028.04 | 28-NOV-09:03 | 2.17 | 0.48 | 0.553405E+09 | 751.33 | 10-NOV-13:00 | 12.00 | 8.90 |
December | 0.255789E+10 | 9262.68 | 30-DEC-00:12 | -2.7 | -4.1 | 0.570727E+09 | 680.12 | 15-DEC-13:09 | 6.00 | 5.05 |
Annual Sum or Average | 0.796849E+11 | 0.767144E+10 | ||||||||
Minimum of Months | 0.255789E+10 | 8028.04 | -3.8 | -5.3 | 0.512756E+09 | 680.12 | 6.00 | 5.05 | ||
Maximum of Months | 0.111991E+11 | 33231.99 | 17.33 | 14.09 | 0.752994E+09 | 899.09 | 22.00 | 19.93 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.156251E+10 | 5336.59 | 10-JAN-09:03 | -3.8 | -5.3 | 0.301014E+09 | 419.60 | 29-JAN-18:00 | 9.00 | 8.43 |
February | 0.156683E+10 | 3930.18 | 17-FEB-09:03 | 1.33 | 0.85 | 0.270596E+09 | 416.26 | 05-FEB-18:00 | 6.00 | 5.04 |
March | 0.191854E+10 | 3577.96 | 15-MAR-08:61 | 2.00 | 1.57 | 0.300897E+09 | 449.47 | 19-MAR-17:00 | 11.00 | 10.48 |
April | 0.353746E+10 | 17698.36 | 29-APR-19:08 | 17.50 | 11.52 | 0.339011E+09 | 449.53 | 30-APR-12:09 | 22.00 | 13.84 |
May | 0.384054E+10 | 17816.25 | 28-MAY-17:01 | 12.00 | 7.58 | 0.355785E+09 | 449.52 | 21-MAY-17:10 | 20.00 | 12.84 |
June | 0.520722E+10 | 18425.70 | 15-JUN-08:62 | 13.00 | 10.80 | 0.360362E+09 | 449.51 | 25-JUN-17:10 | 21.17 | 15.02 |
July | 0.624340E+10 | 18202.99 | 15-JUL-08:62 | 13.17 | 11.37 | 0.376712E+09 | 449.52 | 16-JUL-16:49 | 18.33 | 15.09 |
August | 0.647370E+10 | 18755.11 | 22-AUG-08:62 | 16.00 | 10.46 | 0.371279E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.559015E+10 | 17679.86 | 04-SEP-17:06 | 17.50 | 11.44 | 0.363908E+09 | 449.53 | 24-SEP-16:10 | 21.83 | 15.33 |
October | 0.329649E+10 | 17265.35 | 01-OCT-18:47 | 11.00 | 7.99 | 0.347190E+09 | 449.50 | 08-OCT-17:19 | 12.67 | 12.11 |
November | 0.206974E+10 | 3558.37 | 28-NOV-09:01 | 2.17 | 0.48 | 0.297251E+09 | 449.48 | 05-NOV-17:00 | 6.00 | 5.05 |
December | 0.115005E+10 | 4320.22 | 30-DEC-09:03 | 0.00 | -1.5 | 0.299894E+09 | 411.36 | 24-DEC-18:00 | 6.00 | 5.04 |
Annual Sum or Average | 0.424566E+11 | 0.398390E+10 | ||||||||
Minimum of Months | 0.115005E+10 | 3558.37 | -3.8 | -5.3 | 0.270596E+09 | 411.36 | 6.00 | 5.04 | ||
Maximum of Months | 0.647370E+10 | 18755.11 | 17.50 | 11.52 | 0.376712E+09 | 449.53 | 22.00 | 15.33 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.103519E+10 | 5676.12 | 10-JAN-08:04 | -5.7 | -6.7 | 0.169412E+09 | 340.06 | 28-JAN-13:00 | 11.00 | 9.40 |
February | 0.100269E+10 | 3463.57 | 20-FEB-09:04 | 3.33 | 2.81 | 0.153704E+09 | 345.87 | 04-FEB-13:00 | 9.00 | 6.12 |
March | 0.137225E+10 | 3807.89 | 21-MAR-07:01 | 1.33 | 0.85 | 0.174739E+09 | 380.05 | 25-MAR-12:00 | 14.00 | 11.21 |
April | 0.266304E+10 | 18454.97 | 22-APR-07:01 | 8.83 | 7.43 | 0.194094E+09 | 449.50 | 29-APR-12:00 | 19.00 | 12.78 |
May | 0.289707E+10 | 24240.49 | 01-MAY-07:01 | 7.17 | 5.30 | 0.206754E+09 | 449.49 | 27-MAY-12:00 | 15.00 | 10.67 |
June | 0.354852E+10 | 19888.03 | 03-JUN-07:01 | 10.17 | 9.49 | 0.220726E+09 | 449.49 | 17-JUN-12:20 | 14.67 | 12.93 |
July | 0.422915E+10 | 18997.51 | 01-JUL-07:02 | 13.00 | 9.89 | 0.223546E+09 | 449.50 | 22-JUL-12:09 | 27.17 | 17.04 |
August | 0.457721E+10 | 19170.35 | 23-AUG-07:02 | 14.17 | 9.97 | 0.229909E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.383276E+10 | 22855.20 | 30-SEP-07:01 | 9.33 | 6.73 | 0.218212E+09 | 449.52 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.255154E+10 | 14657.04 | 02-OCT-07:01 | 10.17 | 7.63 | 0.195969E+09 | 449.49 | 07-OCT-12:09 | 16.17 | 10.37 |
November | 0.152472E+10 | 3817.53 | 04-NOV-07:01 | 1.33 | 0.86 | 0.165141E+09 | 357.05 | 25-NOV-13:39 | 10.00 | 5.63 |
December | 0.692958E+09 | 4384.34 | 31-DEC-09:04 | 0.33 | -0.2 | 0.168931E+09 | 340.06 | 23-DEC-13:09 | 9.33 | 6.65 |
Annual Sum or Average | 0.299271E+11 | 0.232114E+10 | ||||||||
Minimum of Months | 0.692958E+09 | 3463.57 | -5.7 | -6.7 | 0.153704E+09 | 340.06 | 9.00 | 5.63 | ||
Maximum of Months | 0.457721E+10 | 24240.49 | 14.17 | 9.97 | 0.229909E+09 | 449.52 | 27.17 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.866007E+09 | 5794.24 | 10-JAN-08:04 | -5.7 | -6.7 | 0.169219E+09 | 340.06 | 28-JAN-13:00 | 11.00 | 9.40 |
February | 0.838439E+09 | 4204.42 | 17-FEB-08:05 | -2.3 | -2.4 | 0.153649E+09 | 342.47 | 04-FEB-13:00 | 9.00 | 6.12 |
March | 0.117490E+10 | 3733.59 | 21-MAR-07:04 | 1.33 | 0.85 | 0.174345E+09 | 375.03 | 25-MAR-12:00 | 14.00 | 11.21 |
April | 0.251533E+10 | 16996.62 | 30-APR-08:62 | 17.50 | 12.50 | 0.191451E+09 | 449.50 | 29-APR-12:00 | 19.00 | 12.78 |
May | 0.278953E+10 | 24113.39 | 01-MAY-07:01 | 7.17 | 5.30 | 0.204010E+09 | 449.49 | 27-MAY-12:00 | 15.00 | 10.67 |
June | 0.345320E+10 | 19477.20 | 10-JUN-07:01 | 11.00 | 9.86 | 0.220410E+09 | 449.49 | 17-JUN-12:20 | 14.67 | 12.93 |
July | 0.415956E+10 | 18816.82 | 15-JUL-07:02 | 12.17 | 10.51 | 0.223459E+09 | 449.50 | 22-JUL-12:09 | 27.17 | 17.04 |
August | 0.451856E+10 | 18563.51 | 23-AUG-07:02 | 14.17 | 9.97 | 0.229895E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.374517E+10 | 22402.42 | 30-SEP-07:01 | 9.33 | 6.73 | 0.218121E+09 | 449.52 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.238439E+10 | 11150.20 | 02-OCT-07:01 | 10.17 | 7.63 | 0.193674E+09 | 449.49 | 07-OCT-12:09 | 16.17 | 10.37 |
November | 0.130586E+10 | 3977.08 | 20-NOV-08:03 | 1.33 | 1.20 | 0.164519E+09 | 349.64 | 25-NOV-13:39 | 10.00 | 5.63 |
December | 0.572595E+09 | 4542.52 | 31-DEC-09:04 | 0.33 | -0.2 | 0.168914E+09 | 340.06 | 23-DEC-13:09 | 9.33 | 6.65 |
Annual Sum or Average | 0.283235E+11 | 0.231167E+10 | ||||||||
Minimum of Months | 0.572595E+09 | 3733.59 | -5.7 | -6.7 | 0.153649E+09 | 340.06 | 9.00 | 5.63 | ||
Maximum of Months | 0.451856E+10 | 24113.39 | 17.50 | 12.50 | 0.229895E+09 | 449.52 | 27.17 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.692320E+09 | 5414.03 | 11-JAN-08:04 | -4.0 | -4.8 | 0.169134E+09 | 340.06 | 28-JAN-13:00 | 11.00 | 9.40 |
February | 0.667186E+09 | 4883.68 | 17-FEB-08:05 | -2.3 | -2.4 | 0.153619E+09 | 340.06 | 04-FEB-13:09 | 9.00 | 6.12 |
March | 0.964632E+09 | 4022.06 | 13-MAR-07:02 | 1.33 | 0.36 | 0.174074E+09 | 369.48 | 25-MAR-12:00 | 14.00 | 11.21 |
April | 0.231841E+10 | 15601.11 | 30-APR-08:62 | 17.50 | 12.50 | 0.188762E+09 | 449.50 | 29-APR-12:00 | 19.00 | 12.78 |
May | 0.262486E+10 | 22274.62 | 01-MAY-07:01 | 7.17 | 5.30 | 0.200801E+09 | 449.49 | 27-MAY-12:00 | 15.00 | 10.67 |
June | 0.325379E+10 | 18750.02 | 15-JUN-07:02 | 12.17 | 10.43 | 0.219721E+09 | 449.49 | 24-JUN-12:09 | 16.83 | 12.75 |
July | 0.397316E+10 | 18757.81 | 15-JUL-07:02 | 12.17 | 10.51 | 0.223269E+09 | 449.50 | 22-JUL-12:09 | 27.17 | 17.04 |
August | 0.433129E+10 | 18244.97 | 29-AUG-07:02 | 12.17 | 10.92 | 0.229854E+09 | 449.52 | 05-AUG-12:30 | 19.50 | 14.42 |
September | 0.355937E+10 | 21981.48 | 28-SEP-07:01 | 8.17 | 7.15 | 0.217920E+09 | 449.52 | 23-SEP-12:00 | 19.00 | 14.77 |
October | 0.217265E+10 | 7168.05 | 02-OCT-07:01 | 10.17 | 7.63 | 0.191447E+09 | 449.49 | 07-OCT-12:09 | 16.17 | 10.37 |
November | 0.109073E+10 | 4107.93 | 20-NOV-08:03 | 1.33 | 1.20 | 0.164122E+09 | 343.55 | 25-NOV-13:39 | 10.00 | 5.63 |
December | 0.442695E+09 | 4536.45 | 27-DEC-08:05 | -1.0 | -1.3 | 0.168902E+09 | 340.06 | 23-DEC-13:09 | 9.33 | 6.65 |
Annual Sum or Average | 0.260911E+11 | 0.230162E+10 | ||||||||
Minimum of Months | 0.442695E+09 | 4022.06 | -4.0 | -4.8 | 0.153619E+09 | 340.06 | 9.00 | 5.63 | ||
Maximum of Months | 0.433129E+10 | 22274.62 | 17.50 | 12.50 | 0.229854E+09 | 449.52 | 27.17 | 17.04 |
Report: ZoneCoolingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.759030E+09 | 11066.84 | 11-JAN-09:04 | -3.8 | -5.1 | 0.578013E+09 | 906.82 | 07-JAN-15:00 | 6.00 | 4.13 |
February | 0.759618E+09 | 8363.45 | 13-FEB-09:04 | 1.33 | 0.55 | 0.526282E+09 | 906.82 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.119291E+10 | 7777.83 | 15-MAR-08:02 | 2.00 | 1.57 | 0.596545E+09 | 934.82 | 25-MAR-14:09 | 11.83 | 9.31 |
April | 0.376106E+10 | 30048.27 | 30-APR-09:02 | 18.33 | 12.09 | 0.631651E+09 | 1198.65 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.435140E+10 | 13716.22 | 24-MAY-08:62 | 12.17 | 10.43 | 0.669282E+09 | 1198.65 | 27-MAY-14:00 | 14.00 | 10.24 |
June | 0.530603E+10 | 31928.42 | 25-JUN-09:02 | 16.33 | 12.17 | 0.746024E+09 | 1198.67 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.652018E+10 | 31765.52 | 27-JUL-08:62 | 13.17 | 11.94 | 0.763212E+09 | 1198.65 | 01-JUL-14:00 | 14.00 | 11.22 |
August | 0.712548E+10 | 33310.97 | 22-AUG-08:62 | 16.00 | 10.46 | 0.788817E+09 | 1198.71 | 19-AUG-14:09 | 19.17 | 14.83 |
September | 0.571771E+10 | 30777.69 | 02-SEP-08:62 | 13.33 | 12.58 | 0.747297E+09 | 1198.70 | 23-SEP-14:30 | 19.00 | 14.77 |
October | 0.333556E+10 | 6555.88 | 05-OCT-20:00 | 5.00 | 4.08 | 0.641017E+09 | 1198.64 | 07-OCT-14:20 | 17.67 | 9.96 |
November | 0.134758E+10 | 8195.00 | 29-NOV-09:04 | 1.17 | -0.1 | 0.557616E+09 | 906.82 | 18-NOV-15:00 | 8.00 | 5.66 |
December | 0.437593E+09 | 9550.89 | 27-DEC-09:04 | -0.7 | -0.8 | 0.578938E+09 | 906.82 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.406141E+11 | 0.782469E+10 | ||||||||
Minimum of Months | 0.437593E+09 | 6555.88 | -3.8 | -5.1 | 0.526282E+09 | 906.82 | 5.00 | 4.13 | ||
Maximum of Months | 0.712548E+10 | 33310.97 | 18.33 | 12.58 | 0.788817E+09 | 1198.71 | 20.00 | 14.83 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.344825E+09 | 5483.88 | 11-JAN-09:04 | -3.8 | -5.1 | 0.288990E+09 | 453.41 | 28-JAN-15:00 | 10.00 | 8.89 |
February | 0.347452E+09 | 4065.86 | 13-FEB-09:04 | 1.33 | 0.55 | 0.263133E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.546656E+09 | 3995.12 | 15-MAR-08:02 | 2.00 | 1.57 | 0.298270E+09 | 467.07 | 25-MAR-14:09 | 11.83 | 9.31 |
April | 0.176530E+10 | 13734.13 | 30-APR-09:02 | 18.33 | 12.09 | 0.314886E+09 | 599.32 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.204546E+10 | 5617.38 | 24-MAY-08:62 | 12.17 | 10.43 | 0.333713E+09 | 599.32 | 27-MAY-14:50 | 14.33 | 10.39 |
June | 0.257685E+10 | 16864.94 | 25-JUN-09:02 | 16.33 | 12.17 | 0.372511E+09 | 599.33 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.324656E+10 | 16790.96 | 27-JUL-08:62 | 13.17 | 11.94 | 0.381525E+09 | 599.32 | 01-JUL-14:50 | 14.17 | 11.22 |
August | 0.358480E+10 | 16792.74 | 22-AUG-08:62 | 16.00 | 10.46 | 0.394404E+09 | 599.36 | 19-AUG-14:20 | 19.33 | 14.89 |
September | 0.283396E+10 | 16272.65 | 02-SEP-08:62 | 13.33 | 12.58 | 0.373695E+09 | 599.35 | 23-SEP-14:30 | 19.00 | 14.77 |
October | 0.155592E+10 | 3215.91 | 05-OCT-20:00 | 5.00 | 4.08 | 0.320173E+09 | 599.32 | 07-OCT-14:20 | 17.67 | 9.96 |
November | 0.620313E+09 | 3968.98 | 29-NOV-09:04 | 1.17 | -0.1 | 0.278826E+09 | 453.41 | 18-NOV-15:00 | 8.00 | 5.66 |
December | 0.197027E+09 | 4657.80 | 27-DEC-09:04 | -0.7 | -0.8 | 0.289469E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.196651E+11 | 0.390960E+10 | ||||||||
Minimum of Months | 0.197027E+09 | 3215.91 | -3.8 | -5.1 | 0.263133E+09 | 453.41 | 5.00 | 5.00 | ||
Maximum of Months | 0.358480E+10 | 16864.94 | 18.33 | 12.58 | 0.394404E+09 | 599.36 | 20.00 | 14.89 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.305269E+09 | 5477.11 | 11-JAN-09:04 | -3.8 | -5.1 | 0.288983E+09 | 453.41 | 28-JAN-15:00 | 10.00 | 8.89 |
February | 0.314972E+09 | 4143.63 | 13-FEB-09:04 | 1.33 | 0.55 | 0.263120E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.498271E+09 | 3775.03 | 14-MAR-08:03 | 3.17 | 2.40 | 0.298207E+09 | 463.87 | 25-MAR-14:09 | 11.83 | 9.31 |
April | 0.168751E+10 | 12153.93 | 30-APR-09:02 | 18.33 | 12.09 | 0.312876E+09 | 599.32 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.195431E+10 | 4197.37 | 24-MAY-08:62 | 12.17 | 10.43 | 0.331465E+09 | 599.32 | 27-MAY-14:50 | 14.33 | 10.39 |
June | 0.247366E+10 | 16656.58 | 25-JUN-09:02 | 16.33 | 12.17 | 0.370694E+09 | 599.33 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.314036E+10 | 16600.19 | 27-JUL-08:62 | 13.17 | 11.94 | 0.381072E+09 | 599.32 | 01-JUL-14:39 | 14.33 | 11.21 |
August | 0.348614E+10 | 15794.30 | 15-AUG-08:62 | 17.67 | 13.86 | 0.394371E+09 | 599.36 | 19-AUG-14:20 | 19.33 | 14.89 |
September | 0.273824E+10 | 16084.74 | 02-SEP-08:62 | 13.33 | 12.58 | 0.373278E+09 | 599.34 | 23-SEP-14:30 | 19.00 | 14.77 |
October | 0.147877E+10 | 3195.92 | 05-OCT-20:00 | 5.00 | 4.08 | 0.318278E+09 | 599.32 | 07-OCT-14:20 | 17.67 | 9.96 |
November | 0.572407E+09 | 4036.20 | 29-NOV-09:04 | 1.17 | -0.1 | 0.278727E+09 | 453.41 | 25-NOV-15:00 | 8.00 | 4.80 |
December | 0.179184E+09 | 4728.34 | 27-DEC-09:04 | -0.7 | -0.8 | 0.289455E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.188291E+11 | 0.390053E+10 | ||||||||
Minimum of Months | 0.179184E+09 | 3195.92 | -3.8 | -5.1 | 0.263120E+09 | 453.41 | 5.00 | 4.80 | ||
Maximum of Months | 0.348614E+10 | 16656.58 | 18.33 | 13.86 | 0.394371E+09 | 599.36 | 20.00 | 14.89 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.203388E+09 | 4690.79 | 12-JAN-09:04 | -1.0 | -2.7 | 0.288941E+09 | 453.41 | 28-JAN-15:39 | 10.33 | 8.88 |
February | 0.206968E+09 | 4311.03 | 17-FEB-09:04 | 1.33 | 0.85 | 0.263081E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 0.357611E+09 | 3876.02 | 15-MAR-08:04 | 2.00 | 1.57 | 0.298103E+09 | 455.24 | 25-MAR-14:09 | 11.83 | 9.31 |
April | 0.149315E+10 | 7885.17 | 30-APR-09:02 | 18.33 | 12.09 | 0.308852E+09 | 599.32 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.172561E+10 | 2757.16 | 22-MAY-15:00 | 24.00 | 16.06 | 0.326675E+09 | 599.32 | 27-MAY-14:20 | 15.33 | 10.80 |
June | 0.224816E+10 | 16178.65 | 25-JUN-09:02 | 16.33 | 12.17 | 0.365800E+09 | 599.33 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.288914E+10 | 15430.36 | 24-JUL-08:62 | 14.17 | 13.49 | 0.379647E+09 | 599.32 | 29-JUL-14:09 | 17.00 | 13.95 |
August | 0.322933E+10 | 15382.05 | 15-AUG-08:62 | 17.67 | 13.86 | 0.394250E+09 | 599.35 | 19-AUG-14:30 | 19.50 | 14.95 |
September | 0.250153E+10 | 13203.19 | 16-SEP-08:62 | 16.17 | 14.82 | 0.371724E+09 | 599.34 | 23-SEP-14:30 | 19.00 | 14.77 |
October | 0.129385E+10 | 3134.77 | 05-OCT-20:00 | 5.00 | 4.08 | 0.313906E+09 | 599.32 | 07-OCT-14:09 | 17.33 | 9.91 |
November | 0.434008E+09 | 4269.64 | 29-NOV-09:04 | 1.17 | -0.1 | 0.278510E+09 | 453.41 | 25-NOV-15:00 | 8.00 | 4.80 |
December | 0.108883E+09 | 4120.15 | 29-DEC-09:04 | 2.00 | -0.1 | 0.289415E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.166916E+11 | 0.387890E+10 | ||||||||
Minimum of Months | 0.108883E+09 | 2757.16 | -1.0 | -2.7 | 0.263081E+09 | 453.41 | 5.00 | 4.80 | ||
Maximum of Months | 0.322933E+10 | 16178.65 | 24.00 | 16.06 | 0.394250E+09 | 599.35 | 20.00 | 14.95 |
Report: ZoneCoolingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 47725490.06 | 5230.80 | 10-JAN-09:05 | -3.8 | -5.3 | 0.288846E+09 | 453.41 | 21-JAN-15:00 | 6.10 | 5.14 |
February | 33995663.86 | 4008.92 | 25-FEB-09:04 | 2.33 | 2.26 | 0.262979E+09 | 453.41 | 25-FEB-15:00 | 5.00 | 5.00 |
March | 94413856.52 | 3876.53 | 31-MAR-08:04 | 3.33 | 2.68 | 0.297918E+09 | 453.41 | 04-MAR-15:09 | 6.00 | 4.33 |
April | 0.106776E+10 | 3815.54 | 30-APR-15:00 | 24.00 | 13.10 | 0.303992E+09 | 599.32 | 29-APR-14:00 | 20.00 | 12.74 |
May | 0.122491E+10 | 2752.85 | 17-MAY-08:05 | 8.17 | 6.64 | 0.318948E+09 | 580.25 | 27-MAY-14:09 | 15.67 | 10.93 |
June | 0.190835E+10 | 13886.04 | 26-JUN-08:62 | 18.17 | 13.95 | 0.354583E+09 | 599.32 | 24-JUN-14:09 | 18.83 | 13.60 |
July | 0.244235E+10 | 14878.78 | 24-JUL-08:62 | 14.17 | 13.49 | 0.376237E+09 | 599.32 | 29-JUL-14:09 | 17.00 | 13.95 |
August | 0.271958E+10 | 11139.46 | 17-AUG-08:62 | 16.50 | 15.52 | 0.393712E+09 | 599.35 | 19-AUG-14:39 | 19.67 | 15.01 |
September | 0.211517E+10 | 4376.27 | 13-SEP-14:10 | 23.00 | 16.21 | 0.366711E+09 | 599.33 | 09-SEP-14:30 | 20.00 | 14.18 |
October | 0.900366E+09 | 2953.90 | 05-OCT-20:00 | 5.00 | 4.08 | 0.307093E+09 | 599.32 | 07-OCT-14:09 | 17.33 | 9.91 |
November | 0.156714E+09 | 3804.74 | 29-NOV-09:05 | 1.17 | -0.1 | 0.278295E+09 | 453.41 | 04-NOV-14:30 | 9.00 | 6.58 |
December | 18629990.48 | 4392.19 | 27-DEC-09:05 | -0.7 | -0.8 | 0.289320E+09 | 453.41 | 23-DEC-15:09 | 9.00 | 6.98 |
Annual Sum or Average | 0.127300E+11 | 0.383863E+10 | ||||||||
Minimum of Months | 18629990.48 | 2752.85 | -3.8 | -5.3 | 0.262979E+09 | 453.41 | 5.00 | 4.33 | ||
Maximum of Months | 0.271958E+10 | 14878.78 | 24.00 | 16.21 | 0.393712E+09 | 599.35 | 20.00 | 15.01 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.105756E+10 | 42674.69 | 05-JAN-09:01 | 3.17 |
February | 0.550258E+09 | 42750.93 | 16-FEB-09:01 | 3.22 |
March | 0.480608E+09 | 43257.46 | 04-MAR-09:01 | 4.33 |
April | 0.177143E+09 | 7732.41 | 01-APR-08:62 | 5.50 |
May | 0.178423E+09 | 2082.99 | 05-MAY-08:07 | 8.17 |
June | 0.152520E+09 | 2183.90 | 25-JUN-07:04 | 14.50 |
July | 0.152075E+09 | 2715.45 | 23-JUL-07:05 | 18.17 |
August | 0.158231E+09 | 2423.08 | 06-AUG-07:03 | 13.17 |
September | 0.157283E+09 | 1778.58 | 21-SEP-07:13 | 9.00 |
October | 0.183329E+09 | 1795.66 | 07-OCT-07:12 | 5.00 |
November | 0.368578E+09 | 41874.58 | 29-NOV-09:01 | 1.17 |
December | 0.129494E+10 | 42718.99 | 15-DEC-09:01 | 3.00 |
Annual Sum or Average | 0.491095E+10 | |||
Minimum of Months | 0.152075E+09 | 1778.58 | 1.17 | |
Maximum of Months | 0.129494E+10 | 43257.46 | 18.17 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.298534E+09 | 18965.51 | 10-JAN-09:01 | -3.8 |
February | 0.122044E+09 | 9720.04 | 17-FEB-09:01 | 1.33 |
March | 0.134525E+09 | 2861.06 | 04-MAR-15:40 | 6.00 |
April | 96244641.20 | 1247.34 | 30-APR-07:05 | 16.23 |
May | 96953085.84 | 1062.92 | 28-MAY-07:03 | 11.50 |
June | 89782904.45 | 1459.64 | 25-JUN-07:04 | 14.50 |
July | 88103937.79 | 1615.90 | 23-JUL-07:05 | 18.17 |
August | 92846346.26 | 1519.19 | 06-AUG-07:03 | 13.17 |
September | 85557983.34 | 1168.72 | 10-SEP-07:04 | 13.33 |
October | 98588368.49 | 1139.12 | 09-OCT-07:03 | 11.17 |
November | 0.134324E+09 | 4662.16 | 29-NOV-09:01 | 1.17 |
December | 0.308528E+09 | 14572.58 | 30-DEC-09:01 | 0.00 |
Annual Sum or Average | 0.164603E+10 | |||
Minimum of Months | 85557983.34 | 1062.92 | -3.8 | |
Maximum of Months | 0.308528E+09 | 18965.51 | 18.17 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.508849E+09 | 16522.17 | 10-JAN-08:62 | -5.7 |
February | 0.233665E+09 | 9543.48 | 17-FEB-08:62 | -2.3 |
March | 0.204138E+09 | 4407.66 | 31-MAR-07:57 | 3.00 |
April | 0.101481E+09 | 1342.92 | 01-APR-07:05 | 4.17 |
May | 0.100212E+09 | 1015.36 | 28-MAY-08:00 | 9.00 |
June | 97628572.73 | 984.70 | 11-JUN-07:02 | 13.17 |
July | 0.105386E+09 | 1964.81 | 22-JUL-17:12 | 29.33 |
August | 0.101649E+09 | 985.10 | 06-AUG-07:02 | 13.17 |
September | 99120249.20 | 991.11 | 21-SEP-06:01 | 5.33 |
October | 0.105188E+09 | 1122.54 | 28-OCT-07:08 | 4.67 |
November | 0.191538E+09 | 4729.98 | 20-NOV-08:61 | 1.33 |
December | 0.610358E+09 | 16935.00 | 31-DEC-09:02 | 0.33 |
Annual Sum or Average | 0.245921E+10 | |||
Minimum of Months | 97628572.73 | 984.70 | -5.7 | |
Maximum of Months | 0.610358E+09 | 16935.00 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.619490E+09 | 20579.20 | 10-JAN-08:62 | -5.7 |
February | 0.306411E+09 | 14650.26 | 20-FEB-09:02 | 3.33 |
March | 0.259556E+09 | 12488.49 | 06-MAR-08:61 | 6.17 |
April | 0.106766E+09 | 3526.50 | 01-APR-07:50 | 4.83 |
May | 99775050.69 | 1009.72 | 28-MAY-08:00 | 9.00 |
June | 97221446.64 | 980.45 | 11-JUN-07:02 | 13.17 |
July | 0.104941E+09 | 1962.87 | 22-JUL-17:12 | 29.33 |
August | 0.101206E+09 | 980.92 | 06-AUG-07:02 | 13.17 |
September | 98704699.56 | 986.88 | 21-SEP-06:01 | 5.33 |
October | 0.106818E+09 | 1332.05 | 24-OCT-07:08 | 6.17 |
November | 0.244096E+09 | 13048.47 | 20-NOV-08:61 | 1.33 |
December | 0.751241E+09 | 21916.80 | 31-DEC-09:02 | 0.33 |
Annual Sum or Average | 0.289623E+10 | |||
Minimum of Months | 97221446.64 | 980.45 | -5.7 | |
Maximum of Months | 0.751241E+09 | 21916.80 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.756434E+09 | 22616.57 | 02-JAN-08:61 | 1.00 |
February | 0.400637E+09 | 18710.41 | 20-FEB-09:02 | 3.33 |
March | 0.333313E+09 | 19011.22 | 06-MAR-08:61 | 6.17 |
April | 0.113079E+09 | 4879.21 | 03-APR-07:06 | 4.67 |
May | 0.100712E+09 | 1014.38 | 28-MAY-08:00 | 9.00 |
June | 97648172.95 | 983.42 | 11-JUN-07:02 | 13.17 |
July | 0.105347E+09 | 1970.69 | 22-JUL-17:12 | 29.33 |
August | 0.101655E+09 | 983.80 | 06-AUG-07:02 | 13.17 |
September | 99140454.80 | 989.94 | 21-SEP-06:01 | 5.33 |
October | 0.111033E+09 | 2865.99 | 30-OCT-08:00 | 7.00 |
November | 0.305683E+09 | 18770.71 | 20-NOV-08:61 | 1.33 |
December | 0.932118E+09 | 22276.68 | 26-DEC-08:62 | 1.17 |
Annual Sum or Average | 0.345680E+10 | |||
Minimum of Months | 97648172.95 | 983.42 | 1.00 | |
Maximum of Months | 0.932118E+09 | 22616.57 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.165577E+10 | 43213.38 | 15-JAN-10:01 | 6.33 |
February | 0.953022E+09 | 43347.77 | 27-FEB-09:01 | 6.00 |
March | 0.813861E+09 | 43938.69 | 06-MAR-09:01 | 7.17 |
April | 0.202850E+09 | 16936.35 | 01-APR-08:62 | 5.50 |
May | 0.179635E+09 | 2084.67 | 06-MAY-08:07 | 8.17 |
June | 0.172244E+09 | 1757.72 | 28-JUN-07:13 | 11.00 |
July | 0.188050E+09 | 3761.06 | 22-JUL-17:12 | 29.33 |
August | 0.176667E+09 | 1754.63 | 29-AUG-07:13 | 12.33 |
September | 0.172319E+09 | 1765.82 | 21-SEP-07:13 | 9.00 |
October | 0.199998E+09 | 15544.61 | 23-OCT-08:62 | 7.33 |
November | 0.712117E+09 | 42404.38 | 27-NOV-09:01 | 4.00 |
December | 0.206426E+10 | 44613.20 | 04-DEC-09:01 | 8.17 |
Annual Sum or Average | 0.749080E+10 | |||
Minimum of Months | 0.172244E+09 | 1754.63 | 4.00 | |
Maximum of Months | 0.206426E+10 | 44613.20 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.101581E+10 | 23138.79 | 15-JAN-10:01 | 6.33 |
February | 0.627129E+09 | 23224.66 | 27-FEB-09:01 | 6.00 |
March | 0.539064E+09 | 23520.41 | 06-MAR-09:01 | 7.17 |
April | 0.121198E+09 | 9457.36 | 01-APR-08:62 | 5.50 |
May | 0.100033E+09 | 1119.73 | 05-MAY-08:07 | 8.17 |
June | 96035308.47 | 968.71 | 10-JUN-07:13 | 11.00 |
July | 0.104410E+09 | 1969.88 | 22-JUL-17:12 | 29.33 |
August | 98565740.81 | 966.43 | 04-AUG-07:13 | 13.33 |
September | 95782086.60 | 972.87 | 21-SEP-07:13 | 9.00 |
October | 0.119230E+09 | 8869.04 | 23-OCT-08:62 | 7.33 |
November | 0.460122E+09 | 22749.08 | 27-NOV-09:01 | 4.00 |
December | 0.125119E+10 | 23853.64 | 04-DEC-09:01 | 8.17 |
Annual Sum or Average | 0.462857E+10 | |||
Minimum of Months | 95782086.60 | 966.43 | 4.00 | |
Maximum of Months | 0.125119E+10 | 23853.64 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.108127E+10 | 23436.18 | 17-JAN-09:01 | 8.25 |
February | 0.690020E+09 | 23082.21 | 27-FEB-09:01 | 6.00 |
March | 0.592454E+09 | 23386.78 | 28-MAR-08:61 | 8.38 |
April | 0.129228E+09 | 11316.91 | 01-APR-08:62 | 5.50 |
May | 99659200.62 | 967.19 | 03-MAY-07:13 | 7.33 |
June | 95454703.63 | 961.53 | 28-JUN-07:13 | 11.00 |
July | 0.103742E+09 | 1966.22 | 22-JUL-17:12 | 29.33 |
August | 98006972.51 | 959.54 | 04-AUG-07:13 | 13.33 |
September | 95197455.65 | 965.85 | 21-SEP-07:13 | 9.00 |
October | 0.126636E+09 | 11045.12 | 23-OCT-08:62 | 7.33 |
November | 0.501809E+09 | 22603.23 | 27-NOV-09:01 | 4.00 |
December | 0.132712E+10 | 23709.98 | 04-DEC-09:01 | 8.17 |
Annual Sum or Average | 0.494060E+10 | |||
Minimum of Months | 95197455.65 | 959.54 | 4.00 | |
Maximum of Months | 0.132712E+10 | 23709.98 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.132007E+10 | 23223.86 | 17-JAN-09:01 | 8.25 |
February | 0.901142E+09 | 22870.78 | 27-FEB-09:01 | 6.00 |
March | 0.797088E+09 | 23246.25 | 28-MAR-08:61 | 8.38 |
April | 0.158796E+09 | 18446.40 | 01-APR-08:62 | 5.50 |
May | 0.103382E+09 | 3908.47 | 17-MAY-08:62 | 8.17 |
June | 94360193.68 | 950.31 | 28-JUN-07:13 | 11.00 |
July | 0.102526E+09 | 1960.08 | 22-JUL-17:12 | 29.33 |
August | 97119799.12 | 948.08 | 29-AUG-07:13 | 12.33 |
September | 94254774.66 | 954.34 | 21-SEP-07:13 | 9.00 |
October | 0.165059E+09 | 18199.95 | 23-OCT-08:62 | 7.33 |
November | 0.660125E+09 | 22567.71 | 21-NOV-09:02 | 6.33 |
December | 0.158590E+10 | 23494.60 | 04-DEC-09:01 | 8.17 |
Annual Sum or Average | 0.607982E+10 | |||
Minimum of Months | 94254774.66 | 948.08 | 5.50 | |
Maximum of Months | 0.158590E+10 | 23494.60 | 29.33 |
Report: ZoneHeatingSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.232023E+10 | 25937.42 | 02-JAN-08:61 | 1.00 |
February | 0.177202E+10 | 25362.21 | 20-FEB-09:02 | 3.33 |
March | 0.161622E+10 | 25779.13 | 06-MAR-08:61 | 6.17 |
April | 0.300779E+09 | 22945.02 | 02-APR-09:02 | 9.17 |
May | 0.192134E+09 | 18892.17 | 17-MAY-08:62 | 8.17 |
June | 92238159.97 | 952.04 | 28-JUN-07:13 | 11.00 |
July | 0.100496E+09 | 1962.43 | 22-JUL-17:12 | 29.33 |
August | 94858810.69 | 949.38 | 04-AUG-07:13 | 13.33 |
September | 92623010.24 | 956.53 | 28-SEP-07:13 | 9.33 |
October | 0.375824E+09 | 22813.54 | 23-OCT-08:62 | 7.33 |
November | 0.126877E+10 | 23059.04 | 27-NOV-08:61 | 4.00 |
December | 0.269327E+10 | 25418.63 | 18-DEC-08:62 | 1.00 |
Annual Sum or Average | 0.109195E+11 | |||
Minimum of Months | 92238159.97 | 949.38 | 1.00 | |
Maximum of Months | 0.269327E+10 | 25937.42 | 29.33 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.114998E+11 | 6976.27 | 01-JAN-10:09 | 0.223514E+10 | 1348.26 | 01-JAN-10:09 |
February | 0.104054E+11 | 6976.27 | 01-FEB-10:09 | 0.202238E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.115236E+11 | 6976.27 | 01-MAR-10:09 | 0.223972E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.111588E+11 | 6976.27 | 01-APR-09:09 | 0.216880E+10 | 1348.26 | 01-APR-09:09 |
May | 0.114998E+11 | 6976.27 | 01-MAY-09:09 | 0.223514E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.111588E+11 | 6976.27 | 01-JUN-09:09 | 0.216880E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.115236E+11 | 6976.27 | 01-JUL-09:09 | 0.223972E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.114998E+11 | 6976.27 | 01-AUG-09:09 | 0.223514E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.111826E+11 | 6976.27 | 01-SEP-09:09 | 0.217339E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.114998E+11 | 6976.27 | 01-OCT-09:09 | 0.223514E+10 | 1348.26 | 01-OCT-09:09 |
November | 0.111112E+11 | 6976.27 | 01-NOV-09:09 | 0.215964E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.115474E+11 | 6976.27 | 01-DEC-10:09 | 0.224431E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.135611E+12 | 0.263573E+11 | ||||
Minimum of Months | 0.104054E+11 | 6976.27 | 0.202238E+10 | 1348.26 | ||
Maximum of Months | 0.115474E+11 | 6976.27 | 0.224431E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.614337E+10 | 3726.82 | 01-JAN-10:09 | 0.111757E+10 | 674.13 | 01-JAN-10:09 |
February | 0.555869E+10 | 3726.82 | 01-FEB-10:09 | 0.101119E+10 | 674.13 | 01-FEB-10:09 |
March | 0.615608E+10 | 3726.82 | 01-MAR-10:09 | 0.111986E+10 | 674.13 | 01-MAR-10:09 |
April | 0.596119E+10 | 3726.82 | 01-APR-09:09 | 0.108440E+10 | 674.13 | 01-APR-09:09 |
May | 0.614337E+10 | 3726.82 | 01-MAY-09:09 | 0.111757E+10 | 674.13 | 01-MAY-09:09 |
June | 0.596119E+10 | 3726.82 | 01-JUN-09:09 | 0.108440E+10 | 674.13 | 01-JUN-09:09 |
July | 0.615608E+10 | 3726.82 | 01-JUL-09:09 | 0.111986E+10 | 674.13 | 01-JUL-09:09 |
August | 0.614337E+10 | 3726.82 | 01-AUG-09:09 | 0.111757E+10 | 674.13 | 01-AUG-09:09 |
September | 0.597390E+10 | 3726.82 | 01-SEP-09:09 | 0.108669E+10 | 674.13 | 01-SEP-09:09 |
October | 0.614337E+10 | 3726.82 | 01-OCT-09:09 | 0.111757E+10 | 674.13 | 01-OCT-09:09 |
November | 0.593577E+10 | 3726.82 | 01-NOV-09:09 | 0.107982E+10 | 674.13 | 01-NOV-09:09 |
December | 0.616879E+10 | 3726.82 | 01-DEC-10:09 | 0.112215E+10 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.724452E+11 | 0.131787E+11 | ||||
Minimum of Months | 0.555869E+10 | 3726.82 | 0.101119E+10 | 674.13 | ||
Maximum of Months | 0.616879E+10 | 3726.82 | 0.112215E+10 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.438359E+10 | 3370.57 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.396975E+10 | 3370.57 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.447555E+10 | 3370.57 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.425331E+10 | 3370.57 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.442957E+10 | 3370.57 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.432228E+10 | 3370.57 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.436060E+10 | 3370.57 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.447555E+10 | 3370.57 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.425331E+10 | 3370.57 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.438359E+10 | 3370.57 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.425331E+10 | 3370.57 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.436060E+10 | 3370.57 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.519210E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.396975E+10 | 3370.57 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.447555E+10 | 3370.57 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.438359E+10 | 3370.57 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.396975E+10 | 3370.57 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.447555E+10 | 3370.57 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.425331E+10 | 3370.57 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.442957E+10 | 3370.57 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.432228E+10 | 3370.57 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.436060E+10 | 3370.57 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.447555E+10 | 3370.57 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.425331E+10 | 3370.57 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.438359E+10 | 3370.57 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.425331E+10 | 3370.57 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.436060E+10 | 3370.57 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.519210E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.396975E+10 | 3370.57 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.447555E+10 | 3370.57 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.438359E+10 | 3370.57 | 01-JAN-10:09 | 0.883781E+09 | 674.13 | 01-JAN-10:09 |
February | 0.396975E+10 | 3370.57 | 01-FEB-09:09 | 0.800324E+09 | 674.13 | 01-FEB-09:09 |
March | 0.447555E+10 | 3370.57 | 01-MAR-09:09 | 0.902118E+09 | 674.13 | 01-MAR-09:09 |
April | 0.425331E+10 | 3370.57 | 01-APR-08:09 | 0.857490E+09 | 674.13 | 01-APR-08:09 |
May | 0.442957E+10 | 3370.57 | 01-MAY-08:09 | 0.892950E+09 | 674.13 | 01-MAY-08:09 |
June | 0.432228E+10 | 3370.57 | 01-JUN-08:09 | 0.871243E+09 | 674.13 | 01-JUN-08:09 |
July | 0.436060E+10 | 3370.57 | 01-JUL-08:09 | 0.879197E+09 | 674.13 | 01-JUL-08:09 |
August | 0.447555E+10 | 3370.57 | 01-AUG-08:09 | 0.902118E+09 | 674.13 | 01-AUG-08:09 |
September | 0.425331E+10 | 3370.57 | 01-SEP-08:09 | 0.857490E+09 | 674.13 | 01-SEP-08:09 |
October | 0.438359E+10 | 3370.57 | 01-OCT-09:09 | 0.883781E+09 | 674.13 | 01-OCT-09:09 |
November | 0.425331E+10 | 3370.57 | 01-NOV-08:09 | 0.857490E+09 | 674.13 | 01-NOV-08:09 |
December | 0.436060E+10 | 3370.57 | 01-DEC-09:09 | 0.879197E+09 | 674.13 | 01-DEC-09:09 |
Annual Sum or Average | 0.519210E+11 | 0.104672E+11 | ||||
Minimum of Months | 0.396975E+10 | 3370.57 | 0.800324E+09 | 674.13 | ||
Maximum of Months | 0.447555E+10 | 3370.57 | 0.902118E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.627948E+10 | 5255.58 | 01-JAN-11:09 | 0.162546E+10 | 1348.26 | 01-JAN-11:09 |
February | 0.568798E+10 | 5255.58 | 01-FEB-10:09 | 0.147229E+10 | 1348.26 | 01-FEB-10:09 |
March | 0.642287E+10 | 5255.58 | 01-MAR-10:09 | 0.166213E+10 | 1348.26 | 01-MAR-10:09 |
April | 0.609426E+10 | 5255.58 | 01-APR-09:09 | 0.157746E+10 | 1348.26 | 01-APR-09:09 |
May | 0.635118E+10 | 5255.58 | 01-MAY-09:09 | 0.164379E+10 | 1348.26 | 01-MAY-09:09 |
June | 0.620181E+10 | 5255.58 | 01-JUN-09:09 | 0.160496E+10 | 1348.26 | 01-JUN-09:09 |
July | 0.624363E+10 | 5255.58 | 01-JUL-09:09 | 0.161629E+10 | 1348.26 | 01-JUL-09:09 |
August | 0.642287E+10 | 5255.58 | 01-AUG-09:09 | 0.166213E+10 | 1348.26 | 01-AUG-09:09 |
September | 0.609426E+10 | 5255.58 | 01-SEP-09:09 | 0.157746E+10 | 1348.26 | 01-SEP-09:09 |
October | 0.627948E+10 | 5255.58 | 01-OCT-10:09 | 0.162546E+10 | 1348.26 | 01-OCT-10:09 |
November | 0.609426E+10 | 5255.58 | 01-NOV-09:09 | 0.157746E+10 | 1348.26 | 01-NOV-09:09 |
December | 0.624363E+10 | 5255.58 | 01-DEC-10:09 | 0.161629E+10 | 1348.26 | 01-DEC-10:09 |
Annual Sum or Average | 0.744157E+11 | 0.192612E+11 | ||||
Minimum of Months | 0.568798E+10 | 5255.58 | 0.147229E+10 | 1348.26 | ||
Maximum of Months | 0.642287E+10 | 5255.58 | 0.166213E+10 | 1348.26 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.313974E+10 | 2627.79 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.284399E+10 | 2627.79 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.321144E+10 | 2627.79 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.304713E+10 | 2627.79 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.317559E+10 | 2627.79 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.310090E+10 | 2627.79 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.312181E+10 | 2627.79 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.321144E+10 | 2627.79 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.304713E+10 | 2627.79 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.313974E+10 | 2627.79 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.304713E+10 | 2627.79 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.312181E+10 | 2627.79 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.372078E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.284399E+10 | 2627.79 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.321144E+10 | 2627.79 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.313974E+10 | 2627.79 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.284399E+10 | 2627.79 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.321144E+10 | 2627.79 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.304713E+10 | 2627.79 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.317559E+10 | 2627.79 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.310090E+10 | 2627.79 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.312181E+10 | 2627.79 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.321144E+10 | 2627.79 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.304713E+10 | 2627.79 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.313974E+10 | 2627.79 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.304713E+10 | 2627.79 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.312181E+10 | 2627.79 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.372078E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.284399E+10 | 2627.79 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.321144E+10 | 2627.79 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.313974E+10 | 2627.79 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.284399E+10 | 2627.79 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.321144E+10 | 2627.79 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.304713E+10 | 2627.79 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.317559E+10 | 2627.79 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.310090E+10 | 2627.79 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.312181E+10 | 2627.79 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.321144E+10 | 2627.79 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.304713E+10 | 2627.79 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.313974E+10 | 2627.79 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.304713E+10 | 2627.79 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.312181E+10 | 2627.79 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.372078E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.284399E+10 | 2627.79 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.321144E+10 | 2627.79 | 0.831065E+09 | 674.13 |
Report: ZoneElectricSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.313974E+10 | 2627.79 | 01-JAN-11:09 | 0.812728E+09 | 674.13 | 01-JAN-11:09 |
February | 0.284399E+10 | 2627.79 | 01-FEB-10:09 | 0.736147E+09 | 674.13 | 01-FEB-10:09 |
March | 0.321144E+10 | 2627.79 | 01-MAR-10:09 | 0.831065E+09 | 674.13 | 01-MAR-10:09 |
April | 0.304713E+10 | 2627.79 | 01-APR-09:09 | 0.788729E+09 | 674.13 | 01-APR-09:09 |
May | 0.317559E+10 | 2627.79 | 01-MAY-09:09 | 0.821897E+09 | 674.13 | 01-MAY-09:09 |
June | 0.310090E+10 | 2627.79 | 01-JUN-09:09 | 0.802482E+09 | 674.13 | 01-JUN-09:09 |
July | 0.312181E+10 | 2627.79 | 01-JUL-09:09 | 0.808144E+09 | 674.13 | 01-JUL-09:09 |
August | 0.321144E+10 | 2627.79 | 01-AUG-09:09 | 0.831065E+09 | 674.13 | 01-AUG-09:09 |
September | 0.304713E+10 | 2627.79 | 01-SEP-09:09 | 0.788729E+09 | 674.13 | 01-SEP-09:09 |
October | 0.313974E+10 | 2627.79 | 01-OCT-10:09 | 0.812728E+09 | 674.13 | 01-OCT-10:09 |
November | 0.304713E+10 | 2627.79 | 01-NOV-09:09 | 0.788729E+09 | 674.13 | 01-NOV-09:09 |
December | 0.312181E+10 | 2627.79 | 01-DEC-10:09 | 0.808144E+09 | 674.13 | 01-DEC-10:09 |
Annual Sum or Average | 0.372078E+11 | 0.963059E+10 | ||||
Minimum of Months | 0.284399E+10 | 2627.79 | 0.736147E+09 | 674.13 | ||
Maximum of Months | 0.321144E+10 | 2627.79 | 0.831065E+09 | 674.13 |
Report: SpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.180574E+10 | 0.114998E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379655E+10 |
February | 0.163016E+10 | 0.104054E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342730E+10 |
March | 0.178954E+10 | 0.115236E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324424E+10 |
April | 0.174484E+10 | 0.111588E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 262783.07 | 0.248572E+10 |
May | 0.179537E+10 | 0.114998E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 18064.52 | 0.303115E+10 |
June | 0.173447E+10 | 0.111588E+11 | 0.216880E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10786799.88 | 0.226292E+10 |
July | 0.181028E+10 | 0.115236E+11 | 0.223972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47485955.12 | 0.188969E+10 |
August | 0.178501E+10 | 0.114998E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6340425.21 | 0.150830E+10 |
September | 0.174937E+10 | 0.111826E+11 | 0.217339E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193727E+10 |
October | 0.180574E+10 | 0.114998E+11 | 0.223514E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278340E+10 |
November | 0.174613E+10 | 0.111112E+11 | 0.215964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344138E+10 |
December | 0.181481E+10 | 0.115474E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.427061E+10 |
Annual Sum or Average | 0.212115E+11 | 0.135611E+12 | 0.263573E+11 | 64894027.80 | 0.340785E+11 | ||||
Minimum of Months | 0.163016E+10 | 0.104054E+11 | 0.202238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150830E+10 |
Maximum of Months | 0.181481E+10 | 0.115474E+11 | 0.224431E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 47485955.12 | 0.427061E+10 |
Report: SpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.902868E+09 | 0.614337E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206048E+10 |
February | 0.815075E+09 | 0.555869E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181485E+10 |
March | 0.894769E+09 | 0.615608E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176564E+10 |
April | 0.872416E+09 | 0.596119E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 144983.73 | 0.137987E+10 |
May | 0.897684E+09 | 0.614337E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9942.59 | 0.156574E+10 |
June | 0.867232E+09 | 0.596119E+10 | 0.108440E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5886415.45 | 0.112304E+10 |
July | 0.905135E+09 | 0.615608E+10 | 0.111986E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25998303.72 | 0.916692E+09 |
August | 0.892501E+09 | 0.614337E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3454542.25 | 0.734248E+09 |
September | 0.874683E+09 | 0.597390E+10 | 0.108669E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.966641E+09 |
October | 0.902868E+09 | 0.614337E+10 | 0.111757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149630E+10 |
November | 0.873064E+09 | 0.593577E+10 | 0.107982E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180760E+10 |
December | 0.907403E+09 | 0.616879E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220501E+10 |
Annual Sum or Average | 0.106057E+11 | 0.724452E+11 | 0.131787E+11 | 35494187.74 | 0.178361E+11 | ||||
Minimum of Months | 0.815075E+09 | 0.555869E+10 | 0.101119E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.734248E+09 |
Maximum of Months | 0.907403E+09 | 0.616879E+10 | 0.112215E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25998303.72 | 0.220501E+10 |
Report: SpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.438359E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206276E+10 |
February | 0.487879E+09 | 0.396975E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.183034E+10 |
March | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.176315E+10 |
April | 0.524810E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69147.61 | 0.136082E+10 |
May | 0.544247E+09 | 0.442957E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9940.68 | 0.157577E+10 |
June | 0.532585E+09 | 0.432228E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5844870.89 | 0.116625E+10 |
July | 0.536472E+09 | 0.436060E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25511983.59 | 0.965704E+09 |
August | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3454556.89 | 0.773058E+09 |
September | 0.524810E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.998792E+09 |
October | 0.537120E+09 | 0.438359E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.148556E+10 |
November | 0.518979E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181524E+10 |
December | 0.536472E+09 | 0.436060E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.224268E+10 |
Annual Sum or Average | 0.638324E+10 | 0.519210E+11 | 0.104672E+11 | 34890499.65 | 0.180401E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.396975E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.773058E+09 |
Maximum of Months | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25511983.59 | 0.224268E+10 |
Report: SpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.438359E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206020E+10 |
February | 0.487879E+09 | 0.396975E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182808E+10 |
March | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175979E+10 |
April | 0.524810E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69147.47 | 0.134208E+10 |
May | 0.544247E+09 | 0.442957E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9940.08 | 0.155352E+10 |
June | 0.532585E+09 | 0.432228E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5845215.60 | 0.116268E+10 |
July | 0.536472E+09 | 0.436060E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25508545.34 | 0.963953E+09 |
August | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3454553.05 | 0.772330E+09 |
September | 0.524810E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.997154E+09 |
October | 0.537120E+09 | 0.438359E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.146804E+10 |
November | 0.518979E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180807E+10 |
December | 0.536472E+09 | 0.436060E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223882E+10 |
Annual Sum or Average | 0.638324E+10 | 0.519210E+11 | 0.104672E+11 | 34887401.55 | 0.179547E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.396975E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.772330E+09 |
Maximum of Months | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25508545.34 | 0.223882E+10 |
Report: SpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.537120E+09 | 0.438359E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205875E+10 |
February | 0.487879E+09 | 0.396975E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182665E+10 |
March | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175785E+10 |
April | 0.524810E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69146.33 | 0.132327E+10 |
May | 0.544247E+09 | 0.442957E+10 | 0.892950E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9939.23 | 0.152823E+10 |
June | 0.532585E+09 | 0.432228E+10 | 0.871243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5845921.78 | 0.115608E+10 |
July | 0.536472E+09 | 0.436060E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25519910.50 | 0.960609E+09 |
August | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3454610.84 | 0.770681E+09 |
September | 0.524810E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.994471E+09 |
October | 0.537120E+09 | 0.438359E+10 | 0.883781E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145201E+10 |
November | 0.518979E+09 | 0.425331E+10 | 0.857490E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180367E+10 |
December | 0.536472E+09 | 0.436060E+10 | 0.879197E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223607E+10 |
Annual Sum or Average | 0.638324E+10 | 0.519210E+11 | 0.104672E+11 | 34899528.68 | 0.178684E+11 | ||||
Minimum of Months | 0.487879E+09 | 0.396975E+10 | 0.800324E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.770681E+09 |
Maximum of Months | 0.551374E+09 | 0.447555E+10 | 0.902118E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25519910.50 | 0.223607E+10 |
Report: SpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.183632E+10 | 0.627948E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.370918E+10 |
February | 0.167188E+10 | 0.568798E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.330593E+10 |
March | 0.189386E+10 | 0.642287E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.316640E+10 |
April | 0.180380E+10 | 0.609426E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 124145.18 | 0.234034E+10 |
May | 0.186509E+10 | 0.635118E+10 | 0.164379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17855.54 | 0.274376E+10 |
June | 0.182945E+10 | 0.620181E+10 | 0.160496E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10514374.17 | 0.209916E+10 |
July | 0.183943E+10 | 0.624363E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45889967.04 | 0.176528E+10 |
August | 0.189386E+10 | 0.642287E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 6212473.53 | 0.142180E+10 |
September | 0.180380E+10 | 0.609426E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181990E+10 |
October | 0.183632E+10 | 0.627948E+10 | 0.162546E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.259689E+10 |
November | 0.176881E+10 | 0.609426E+10 | 0.157746E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.327631E+10 |
December | 0.183943E+10 | 0.624363E+10 | 0.161629E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.406578E+10 |
Annual Sum or Average | 0.218821E+11 | 0.744157E+11 | 0.192612E+11 | 62758815.46 | 0.323107E+11 | ||||
Minimum of Months | 0.167188E+10 | 0.568798E+10 | 0.147229E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142180E+10 |
Maximum of Months | 0.189386E+10 | 0.642287E+10 | 0.166213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45889967.04 | 0.406578E+10 |
Report: SpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205774E+10 |
February | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182730E+10 |
March | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175642E+10 |
April | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69194.86 | 0.129006E+10 |
May | 0.932542E+09 | 0.317559E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9940.88 | 0.149448E+10 |
June | 0.914724E+09 | 0.310090E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5848041.08 | 0.114286E+10 |
July | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25558474.10 | 0.959516E+09 |
August | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3454805.84 | 0.774067E+09 |
September | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.995584E+09 |
October | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142817E+10 |
November | 0.884402E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180511E+10 |
December | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223818E+10 |
Annual Sum or Average | 0.109410E+11 | 0.372078E+11 | 0.963059E+10 | 34940456.76 | 0.177695E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.774067E+09 |
Maximum of Months | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25558474.10 | 0.223818E+10 |
Report: SpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205703E+10 |
February | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182641E+10 |
March | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175568E+10 |
April | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69194.15 | 0.128180E+10 |
May | 0.932542E+09 | 0.317559E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9942.58 | 0.148348E+10 |
June | 0.914724E+09 | 0.310090E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5848238.64 | 0.113443E+10 |
July | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25565226.18 | 0.956217E+09 |
August | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3454888.39 | 0.773061E+09 |
September | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.993019E+09 |
October | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141990E+10 |
November | 0.884402E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.180373E+10 |
December | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223683E+10 |
Annual Sum or Average | 0.109410E+11 | 0.372078E+11 | 0.963059E+10 | 34947489.94 | 0.177216E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.773061E+09 |
Maximum of Months | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25565226.18 | 0.223683E+10 |
Report: SpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205447E+10 |
February | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182316E+10 |
March | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.175328E+10 |
April | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69192.16 | 0.126463E+10 |
May | 0.932542E+09 | 0.317559E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 9999.62 | 0.145868E+10 |
June | 0.914724E+09 | 0.310090E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 5848789.82 | 0.111149E+10 |
July | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25580059.54 | 0.946154E+09 |
August | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3454855.88 | 0.769704E+09 |
September | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.984080E+09 |
October | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140001E+10 |
November | 0.884402E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179927E+10 |
December | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.223173E+10 |
Annual Sum or Average | 0.109410E+11 | 0.372078E+11 | 0.963059E+10 | 34962897.03 | 0.175967E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.769704E+09 |
Maximum of Months | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 25580059.54 | 0.223173E+10 |
Report: SpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.217660E+10 |
February | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200643E+10 |
March | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.185850E+10 |
April | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 69605.58 | 0.136535E+10 |
May | 0.932542E+09 | 0.317559E+10 | 0.821897E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 10204.87 | 0.175557E+10 |
June | 0.914724E+09 | 0.310090E+10 | 0.802482E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 6052834.68 | 0.133613E+10 |
July | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 26375902.70 | 0.119159E+10 |
August | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 3582997.24 | 0.970782E+09 |
September | 0.901896E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117811E+10 |
October | 0.918158E+09 | 0.313974E+10 | 0.812728E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157255E+10 |
November | 0.884402E+09 | 0.304713E+10 | 0.788729E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.204536E+10 |
December | 0.919713E+09 | 0.312181E+10 | 0.808144E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.256419E+10 |
Annual Sum or Average | 0.109410E+11 | 0.372078E+11 | 0.963059E+10 | 36091545.08 | 0.200212E+11 | ||||
Minimum of Months | 0.835938E+09 | 0.284399E+10 | 0.736147E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.970782E+09 |
Maximum of Months | 0.946926E+09 | 0.321144E+10 | 0.831065E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 26375902.70 | 0.256419E+10 |
Report: PeakSpaceGainsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2159.72 | 01-JAN-13:09 | 6976.27 | 01-JAN-10:09 | 1348.26 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 8008.29 | 11-JAN-18:00 |
February | 2159.72 | 03-FEB-13:09 | 6976.27 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 6021.79 | 24-FEB-18:00 |
March | 2159.72 | 03-MAR-13:09 | 6976.27 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6220.35 | 15-MAR-12:00 |
April | 2159.72 | 01-APR-12:09 | 6976.27 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.99 | 30-APR-17:00 | 4389.65 | 10-APR-11:10 |
May | 2159.72 | 05-MAY-12:09 | 6976.27 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 30.11 | 22-MAY-15:00 | 4797.82 | 01-MAY-15:00 |
June | 2159.72 | 02-JUN-12:09 | 6976.27 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 906.18 | 13-JUN-17:00 | 4069.99 | 07-JUN-15:00 |
July | 2159.72 | 01-JUL-12:09 | 6976.27 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1478.53 | 22-JUL-15:00 | 3578.63 | 04-JUL-14:00 |
August | 2159.72 | 04-AUG-12:09 | 6976.27 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 903.81 | 14-AUG-17:00 | 2485.13 | 30-AUG-17:00 |
September | 2159.72 | 01-SEP-12:09 | 6976.27 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3608.19 | 30-SEP-11:10 |
October | 2159.72 | 01-OCT-12:09 | 6976.27 | 01-OCT-09:09 | 1348.26 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 3956.19 | 27-OCT-17:00 |
November | 2159.72 | 03-NOV-12:09 | 6976.27 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 6540.16 | 28-NOV-18:00 |
December | 2159.72 | 01-DEC-13:09 | 6976.27 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 7439.35 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2159.72 | 6976.27 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2485.13 | |||||
Maximum of Months | 2159.72 | 6976.27 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1478.53 | 8008.29 |
Report: PeakSpaceGainsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 01-JAN-13:09 | 3726.82 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.44 | 11-JAN-18:00 |
February | 1079.86 | 03-FEB-13:09 | 3726.82 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.94 | 24-FEB-18:00 |
March | 1079.86 | 03-MAR-13:09 | 3726.82 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.27 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 3726.82 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.59 | 30-APR-17:00 | 2422.32 | 10-APR-11:10 |
May | 1079.86 | 05-MAY-12:09 | 3726.82 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 22-MAY-15:00 | 2662.45 | 01-MAY-15:00 |
June | 1079.86 | 02-JUN-12:09 | 3726.82 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2315.85 | 07-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3726.82 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 22-JUL-15:00 | 2010.92 | 04-JUL-14:00 |
August | 1079.86 | 04-AUG-12:09 | 3726.82 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.49 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1079.86 | 01-SEP-12:09 | 3726.82 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 2033.39 | 08-SEP-11:10 |
October | 1079.86 | 01-OCT-12:09 | 3726.82 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2266.81 | 21-OCT-17:00 |
November | 1079.86 | 03-NOV-12:09 | 3726.82 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.16 | 28-NOV-18:00 |
December | 1079.86 | 01-DEC-13:09 | 3726.82 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.99 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3726.82 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1079.86 | 3726.82 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 4432.44 |
Report: PeakSpaceGainsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3370.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.44 | 11-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3370.57 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.67 | 24-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3370.57 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.28 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 3370.57 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.53 | 30-APR-15:00 | 2416.48 | 10-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3370.57 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 22-MAY-15:00 | 2650.81 | 01-MAY-15:00 |
June | 1079.86 | 03-JUN-12:09 | 3370.57 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2291.20 | 07-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3370.57 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 22-JUL-15:00 | 1994.47 | 04-JUL-14:00 |
August | 1079.86 | 05-AUG-12:09 | 3370.57 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.48 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 3370.57 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 2016.02 | 08-SEP-11:10 |
October | 1079.86 | 07-OCT-12:09 | 3370.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2190.96 | 21-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 3370.57 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.16 | 28-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3370.57 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.98 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3370.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1079.86 | 3370.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 4432.44 |
Report: PeakSpaceGainsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3370.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.44 | 11-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3370.57 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.94 | 24-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3370.57 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.28 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 3370.57 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.53 | 30-APR-15:00 | 2416.48 | 10-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3370.57 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 22-MAY-15:00 | 2644.32 | 01-MAY-15:00 |
June | 1079.86 | 03-JUN-12:09 | 3370.57 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2271.06 | 07-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3370.57 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 22-JUL-15:00 | 1981.21 | 04-JUL-14:00 |
August | 1079.86 | 05-AUG-12:09 | 3370.57 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.48 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 3370.57 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 2005.14 | 08-SEP-11:10 |
October | 1079.86 | 07-OCT-12:09 | 3370.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2189.67 | 27-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 3370.57 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.16 | 28-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3370.57 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.98 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3370.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1079.86 | 3370.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 4432.44 |
Report: PeakSpaceGainsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1079.86 | 07-JAN-13:09 | 3370.57 | 01-JAN-10:09 | 674.13 | 01-JAN-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.44 | 11-JAN-18:00 |
February | 1079.86 | 04-FEB-13:09 | 3370.57 | 01-FEB-09:09 | 674.13 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.92 | 24-FEB-18:00 |
March | 1079.86 | 04-MAR-13:09 | 3370.57 | 01-MAR-09:09 | 674.13 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.28 | 15-MAR-12:00 |
April | 1079.86 | 01-APR-12:09 | 3370.57 | 01-APR-08:09 | 674.13 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.53 | 30-APR-15:00 | 2416.48 | 10-APR-11:10 |
May | 1079.86 | 06-MAY-12:09 | 3370.57 | 01-MAY-08:09 | 674.13 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 22-MAY-15:00 | 2624.12 | 01-MAY-15:00 |
June | 1079.86 | 03-JUN-12:09 | 3370.57 | 01-JUN-08:09 | 674.13 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2232.84 | 07-JUN-11:10 |
July | 1079.86 | 01-JUL-12:09 | 3370.57 | 01-JUL-08:09 | 674.13 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 22-JUL-15:00 | 1956.25 | 04-JUL-14:00 |
August | 1079.86 | 05-AUG-12:09 | 3370.57 | 01-AUG-08:09 | 674.13 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.48 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1079.86 | 02-SEP-12:09 | 3370.57 | 01-SEP-08:09 | 674.13 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1987.04 | 30-SEP-11:10 |
October | 1079.86 | 07-OCT-12:09 | 3370.57 | 01-OCT-09:09 | 674.13 | 01-OCT-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2189.67 | 27-OCT-17:00 |
November | 1079.86 | 04-NOV-12:09 | 3370.57 | 01-NOV-08:09 | 674.13 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.16 | 28-NOV-18:00 |
December | 1079.86 | 02-DEC-13:09 | 3370.57 | 01-DEC-09:09 | 674.13 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.98 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1079.86 | 3370.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1079.86 | 3370.57 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.85 | 4432.44 |
Report: PeakSpaceGainsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 2879.63 | 07-JAN-15:09 | 5255.58 | 01-JAN-11:09 | 1348.26 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 7954.70 | 11-JAN-18:00 |
February | 2879.63 | 04-FEB-15:09 | 5255.58 | 01-FEB-10:09 | 1348.26 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 5965.70 | 24-FEB-18:00 |
March | 2879.63 | 04-MAR-15:09 | 5255.58 | 01-MAR-10:09 | 1348.26 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 6220.33 | 15-MAR-12:00 |
April | 2879.63 | 01-APR-14:09 | 5255.58 | 01-APR-09:09 | 1348.26 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.69 | 30-APR-15:00 | 4339.65 | 10-APR-11:10 |
May | 2879.63 | 06-MAY-14:09 | 5255.58 | 01-MAY-09:09 | 1348.26 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 29.76 | 22-MAY-15:00 | 4655.98 | 01-MAY-15:00 |
June | 2879.63 | 03-JUN-14:09 | 5255.58 | 01-JUN-09:09 | 1348.26 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 893.84 | 13-JUN-17:00 | 3845.42 | 07-JUN-15:00 |
July | 2879.63 | 01-JUL-14:09 | 5255.58 | 01-JUL-09:09 | 1348.26 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1458.48 | 22-JUL-15:00 | 3380.66 | 04-JUL-14:00 |
August | 2879.63 | 05-AUG-14:09 | 5255.58 | 01-AUG-09:09 | 1348.26 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 893.46 | 14-AUG-17:00 | 2419.63 | 30-AUG-17:00 |
September | 2879.63 | 02-SEP-14:09 | 5255.58 | 01-SEP-09:09 | 1348.26 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 3550.60 | 30-SEP-11:10 |
October | 2879.63 | 07-OCT-14:09 | 5255.58 | 01-OCT-10:09 | 1348.26 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 3929.72 | 27-OCT-17:00 |
November | 2879.63 | 04-NOV-14:09 | 5255.58 | 01-NOV-09:09 | 1348.26 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 6451.22 | 28-NOV-18:00 |
December | 2879.63 | 02-DEC-15:09 | 5255.58 | 01-DEC-10:09 | 1348.26 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 7354.06 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 2879.63 | 5255.58 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2419.63 | |||||
Maximum of Months | 2879.63 | 5255.58 | 1348.26 | 0.00 | 0.00 | 0.00 | 0.00 | 1458.48 | 7954.70 |
Report: PeakSpaceGainsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 2627.79 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.43 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 2627.79 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.91 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 2627.79 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.27 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 2627.79 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.54 | 30-APR-15:00 | 2416.48 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 2627.79 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 22-MAY-15:00 | 2578.91 | 01-MAY-15:00 |
June | 1439.81 | 03-JUN-14:09 | 2627.79 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2132.53 | 07-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 2627.79 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.88 | 22-JUL-15:00 | 1874.73 | 04-JUL-14:00 |
August | 1439.81 | 05-AUG-14:09 | 2627.79 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.49 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 2627.79 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1974.84 | 30-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 2627.79 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2189.67 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 2627.79 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.15 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 2627.79 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.98 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.88 | 4432.43 |
Report: PeakSpaceGainsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 2627.79 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.43 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 2627.79 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.91 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 2627.79 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.27 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 2627.79 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.54 | 30-APR-15:00 | 2416.48 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 2627.79 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.57 | 22-MAY-15:00 | 2561.52 | 01-MAY-15:00 |
June | 1439.81 | 03-JUN-14:09 | 2627.79 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2101.10 | 07-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 2627.79 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.88 | 22-JUL-15:00 | 1851.73 | 04-JUL-14:00 |
August | 1439.81 | 05-AUG-14:09 | 2627.79 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.49 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 2627.79 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1971.19 | 30-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 2627.79 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2188.70 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 2627.79 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.15 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 2627.79 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.98 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.88 | 4432.43 |
Report: PeakSpaceGainsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 2627.79 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4432.43 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 2627.79 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3322.91 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 2627.79 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.27 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 2627.79 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.54 | 30-APR-15:00 | 2416.48 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 2627.79 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 22-MAY-15:00 | 2517.08 | 01-MAY-15:00 |
June | 1439.81 | 03-JUN-14:09 | 2627.79 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.56 | 13-JUN-17:00 | 2034.93 | 07-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 2627.79 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 811.88 | 22-JUL-15:00 | 1800.04 | 04-JUL-14:00 |
August | 1439.81 | 05-AUG-14:09 | 2627.79 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 497.49 | 14-AUG-17:00 | 1344.43 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 2627.79 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1960.13 | 30-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 2627.79 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2189.67 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 2627.79 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3591.15 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 2627.79 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4094.97 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1344.43 | |||||
Maximum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 811.88 | 4432.43 |
Report: PeakSpaceGainsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1439.81 | 07-JAN-15:09 | 2627.79 | 01-JAN-11:09 | 674.13 | 01-JAN-11:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 4485.93 | 11-JAN-18:00 |
February | 1439.81 | 04-FEB-15:09 | 2627.79 | 01-FEB-10:09 | 674.13 | 01-FEB-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 3378.87 | 24-FEB-18:00 |
March | 1439.81 | 04-MAR-15:09 | 2627.79 | 01-MAR-10:09 | 674.13 | 01-MAR-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3469.27 | 15-MAR-12:00 |
April | 1439.81 | 01-APR-14:09 | 2627.79 | 01-APR-09:09 | 674.13 | 01-APR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 16.74 | 30-APR-15:00 | 2466.41 | 10-APR-11:10 |
May | 1439.81 | 06-MAY-14:09 | 2627.79 | 01-MAY-09:09 | 674.13 | 01-MAY-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 17.01 | 22-MAY-15:00 | 2534.73 | 01-MAY-15:00 |
June | 1439.81 | 03-JUN-14:09 | 2627.79 | 01-JUN-09:09 | 674.13 | 01-JUN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 509.85 | 13-JUN-17:00 | 2077.88 | 07-JUN-11:10 |
July | 1439.81 | 01-JUL-14:09 | 2627.79 | 01-JUL-09:09 | 674.13 | 01-JUL-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 831.95 | 22-JUL-15:00 | 1742.27 | 04-JUL-14:00 |
August | 1439.81 | 05-AUG-14:09 | 2627.79 | 01-AUG-09:09 | 674.13 | 01-AUG-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 507.83 | 14-AUG-17:00 | 1409.84 | 30-AUG-17:00 |
September | 1439.81 | 02-SEP-14:09 | 2627.79 | 01-SEP-09:09 | 674.13 | 01-SEP-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 1964.50 | 30-SEP-11:10 |
October | 1439.81 | 07-OCT-14:09 | 2627.79 | 01-OCT-10:09 | 674.13 | 01-OCT-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:05 | 2216.10 | 27-OCT-17:00 |
November | 1439.81 | 04-NOV-14:09 | 2627.79 | 01-NOV-09:09 | 674.13 | 01-NOV-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 3679.96 | 28-NOV-18:00 |
December | 1439.81 | 02-DEC-15:09 | 2627.79 | 01-DEC-10:09 | 674.13 | 01-DEC-10:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 4180.14 | 29-DEC-18:00 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1409.84 | |||||
Maximum of Months | 1439.81 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 831.95 | 4485.93 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 10844.33 | 10-JAN-09:04 | 1439.81 | 29373.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1241.76 |
February | 8676.14 | 17-FEB-00:12 | 719.91 | 14686.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.13 |
March | 8128.54 | 15-MAR-08:02 | 1439.81 | 29373.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 882.89 |
April | 13625.46 | 29-APR-08:62 | 719.91 | 14686.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 354.82 |
May | 21734.38 | 23-MAY-08:62 | 719.91 | 14686.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 319.73 |
June | 32127.49 | 24-JUN-08:62 | 899.88 | 18358.60 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 456.40 |
July | 32079.30 | 27-JUL-08:62 | 899.88 | 18358.60 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 486.61 |
August | 33231.99 | 22-AUG-08:62 | 899.88 | 18358.60 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 424.28 |
September | 31051.58 | 02-SEP-08:62 | 899.88 | 18358.60 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 478.03 |
October | 8107.74 | 01-OCT-17:02 | 17277.75 | 55810.15 | 10786.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 677.18 |
November | 8028.04 | 28-NOV-09:03 | 1439.81 | 29373.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1017.37 |
December | 9262.68 | 30-DEC-00:12 | 719.91 | 14686.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 260.11 |
Annual Sum or Average | |||||||||||
Minimum of Months | 8028.04 | 719.91 | 14686.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 136.13 | |
Maximum of Months | 33231.99 | 17277.75 | 55810.15 | 10786.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1241.76 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5336.59 | 10-JAN-09:03 | 719.90 | 15691.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 636.27 |
February | 3930.18 | 17-FEB-09:03 | 719.90 | 15691.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 451.88 |
March | 3577.96 | 15-MAR-08:61 | 719.90 | 15691.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 462.12 |
April | 17698.36 | 29-APR-19:08 | 4319.42 | 29814.58 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 17816.25 | 28-MAY-17:01 | 9718.70 | 33541.40 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 296.99 |
June | 18425.70 | 15-JUN-08:62 | 359.95 | 7845.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 256.70 |
July | 18202.99 | 15-JUL-08:62 | 359.95 | 7845.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 262.63 |
August | 18755.11 | 22-AUG-08:62 | 449.94 | 9807.43 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 213.85 |
September | 17679.86 | 04-SEP-17:06 | 8638.85 | 29814.58 | 5393.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 135.68 |
October | 17265.35 | 01-OCT-18:47 | 6479.14 | 33541.40 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 313.68 |
November | 3558.37 | 28-NOV-09:01 | 719.90 | 15691.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 502.91 |
December | 4320.22 | 30-DEC-09:03 | 719.90 | 15691.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 522.39 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3558.37 | 359.95 | 7845.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18755.11 | 9718.70 | 33541.40 | 6067.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 636.27 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5676.12 | 10-JAN-08:04 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 629.86 |
February | 3463.57 | 20-FEB-09:04 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 426.67 |
March | 3807.89 | 21-MAR-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 458.65 |
April | 18454.97 | 22-APR-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 339.73 |
May | 24240.49 | 01-MAY-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 453.97 |
June | 19888.03 | 03-JUN-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 323.36 |
July | 18997.51 | 01-JUL-07:02 | 539.93 | 10643.91 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 289.02 |
August | 19170.35 | 23-AUG-07:02 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.38 |
September | 22855.20 | 30-SEP-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 325.66 |
October | 14657.04 | 02-OCT-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 352.15 |
November | 3817.53 | 04-NOV-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 496.24 |
December | 4384.34 | 31-DEC-09:04 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 502.89 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3463.57 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.38 | |
Maximum of Months | 24240.49 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 629.86 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5794.24 | 10-JAN-08:04 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 631.30 |
February | 4204.42 | 17-FEB-08:05 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 541.33 |
March | 3733.59 | 21-MAR-07:04 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 448.57 |
April | 16996.62 | 30-APR-08:62 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.04 |
May | 24113.39 | 01-MAY-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 453.34 |
June | 19477.20 | 10-JUN-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 290.34 |
July | 18816.82 | 15-JUL-07:02 | 539.93 | 10643.91 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 291.02 |
August | 18563.51 | 23-AUG-07:02 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.06 |
September | 22402.42 | 30-SEP-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 324.34 |
October | 11150.20 | 02-OCT-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 351.98 |
November | 3977.08 | 20-NOV-08:03 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 463.85 |
December | 4542.52 | 31-DEC-09:04 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 505.86 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3733.59 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 153.04 | |
Maximum of Months | 24113.39 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 631.30 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5414.03 | 11-JAN-08:04 | 449.94 | 8869.93 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 614.44 |
February | 4883.68 | 17-FEB-08:05 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 542.17 |
March | 4022.06 | 13-MAR-07:02 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 448.80 |
April | 15601.11 | 30-APR-08:62 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.43 |
May | 22274.62 | 01-MAY-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 451.28 |
June | 18750.02 | 15-JUN-07:02 | 539.93 | 10643.91 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 280.11 |
July | 18757.81 | 15-JUL-07:02 | 539.93 | 10643.91 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 287.97 |
August | 18244.97 | 29-AUG-07:02 | 539.93 | 10643.91 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 296.01 |
September | 21981.48 | 28-SEP-07:01 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 349.14 |
October | 7168.05 | 02-OCT-07:01 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 351.79 |
November | 4107.93 | 20-NOV-08:03 | 629.92 | 12417.90 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 466.46 |
December | 4536.45 | 27-DEC-08:05 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 542.85 |
Annual Sum or Average | |||||||||||
Minimum of Months | 4022.06 | 359.95 | 7095.94 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.43 | |
Maximum of Months | 22274.62 | 719.90 | 14191.88 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 614.44 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 11066.84 | 11-JAN-09:04 | 3167.59 | 22128.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1103.22 |
February | 8363.45 | 13-FEB-09:04 | 3167.59 | 22128.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 847.18 |
March | 7777.83 | 15-MAR-08:02 | 3167.59 | 22128.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 832.60 |
April | 30048.27 | 30-APR-09:02 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 253.62 |
May | 13716.22 | 24-MAY-08:62 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 524.81 |
June | 31928.42 | 25-JUN-09:02 | 1979.74 | 13830.47 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 340.22 |
July | 31765.52 | 27-JUL-08:62 | 1979.74 | 13830.47 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 463.91 |
August | 33310.97 | 22-AUG-08:62 | 1979.74 | 13830.47 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 376.45 |
September | 30777.69 | 02-SEP-08:62 | 1979.74 | 13830.47 | 3745.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 452.09 |
October | 6555.88 | 05-OCT-20:00 | 395.95 | 2766.09 | 749.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.19 |
November | 8195.00 | 29-NOV-09:04 | 3167.59 | 22128.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 837.64 |
December | 9550.89 | 27-DEC-09:04 | 3167.59 | 22128.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 915.78 |
Annual Sum or Average | |||||||||||
Minimum of Months | 6555.88 | 395.95 | 2766.09 | 749.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48.19 | |
Maximum of Months | 33310.97 | 3167.59 | 22128.76 | 5992.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1103.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5483.88 | 11-JAN-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 613.00 |
February | 4065.86 | 13-FEB-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 469.04 |
March | 3995.12 | 15-MAR-08:02 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 461.95 |
April | 13734.13 | 30-APR-09:02 | 791.89 | 5532.19 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139.07 |
May | 5617.38 | 24-MAY-08:62 | 791.89 | 5532.19 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 288.95 |
June | 16864.94 | 25-JUN-09:02 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.06 |
July | 16790.96 | 27-JUL-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 253.90 |
August | 16792.74 | 22-AUG-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 204.60 |
September | 16272.65 | 02-SEP-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 247.71 |
October | 3215.91 | 05-OCT-20:00 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.30 |
November | 3968.98 | 29-NOV-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 465.37 |
December | 4657.80 | 27-DEC-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 508.96 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3215.91 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.30 | |
Maximum of Months | 16864.94 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 613.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5477.11 | 11-JAN-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 610.98 |
February | 4143.63 | 13-FEB-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 470.51 |
March | 3775.03 | 14-MAR-08:03 | 1385.82 | 9681.33 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 416.71 |
April | 12153.93 | 30-APR-09:02 | 791.89 | 5532.19 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.84 |
May | 4197.37 | 24-MAY-08:62 | 791.89 | 5532.19 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 288.76 |
June | 16656.58 | 25-JUN-09:02 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 183.17 |
July | 16600.19 | 27-JUL-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 252.44 |
August | 15794.30 | 15-AUG-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 144.31 |
September | 16084.74 | 02-SEP-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 246.24 |
October | 3195.92 | 05-OCT-20:00 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.14 |
November | 4036.20 | 29-NOV-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 466.59 |
December | 4728.34 | 27-DEC-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 510.28 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3195.92 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.14 | |
Maximum of Months | 16656.58 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 610.98 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4690.79 | 12-JAN-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 536.23 |
February | 4311.03 | 17-FEB-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 457.26 |
March | 3876.02 | 15-MAR-08:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 463.46 |
April | 7885.17 | 30-APR-09:02 | 791.89 | 5532.19 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 138.23 |
May | 2757.16 | 22-MAY-15:00 | 1241.83 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 0.00 |
June | 16178.65 | 25-JUN-09:02 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 176.90 |
July | 15430.36 | 24-JUL-08:62 | 1187.84 | 8298.28 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 242.97 |
August | 15382.05 | 15-AUG-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 139.65 |
September | 13203.19 | 16-SEP-08:62 | 989.87 | 6915.24 | 1872.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 168.27 |
October | 3134.77 | 05-OCT-20:00 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.72 |
November | 4269.64 | 29-NOV-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 471.19 |
December | 4120.15 | 29-DEC-09:04 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 507.50 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2757.16 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16178.65 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 16.67 | 536.23 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5230.80 | 10-JAN-09:05 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 721.54 |
February | 4008.92 | 25-FEB-09:04 | 1385.82 | 9681.33 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 434.24 |
March | 3876.53 | 31-MAR-08:04 | 1385.82 | 9681.33 | 2621.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 652.61 |
April | 3815.54 | 30-APR-15:00 | 1241.83 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 16.74 | 0.00 |
May | 2752.85 | 17-MAY-08:05 | 791.89 | 5532.19 | 1498.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 370.54 |
June | 13886.04 | 26-JUN-08:62 | 1187.84 | 8298.28 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.91 |
July | 14878.78 | 24-JUL-08:62 | 1187.84 | 8298.28 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 248.56 |
August | 11139.46 | 17-AUG-08:62 | 1187.84 | 8298.28 | 2247.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.16 |
September | 4376.27 | 13-SEP-14:10 | 1241.83 | 2627.79 | 674.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 150.49 |
October | 2953.90 | 05-OCT-20:00 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 56.62 |
November | 3804.74 | 29-NOV-09:05 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 477.47 |
December | 4392.19 | 27-DEC-09:05 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 514.93 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2752.85 | 197.97 | 1383.05 | 374.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14878.78 | 1583.79 | 11064.38 | 2996.12 | 0.00 | 0.00 | 0.00 | 0.00 | 16.74 | 721.54 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.950543E+11 | 73100.01 | 07-JAN-17:49 | 0.602362E+11 | 149961.26 | 10-JAN-09:09 |
February | 0.850732E+11 | 73099.66 | 22-FEB-17:49 | 0.474558E+11 | 113105.38 | 13-FEB-09:09 |
March | 0.938944E+11 | 72153.62 | 28-MAR-18:49 | 0.407278E+11 | 95824.29 | 15-MAR-08:09 |
April | 0.890646E+11 | 79062.40 | 30-APR-15:20 | 0.598887E+10 | 59596.53 | 01-APR-08:09 |
May | 0.910586E+11 | 76817.76 | 22-MAY-15:30 | 0.252617E+10 | 23318.54 | 17-MAY-08:09 |
June | 0.902702E+11 | 85579.54 | 13-JUN-16:10 | 33869725.02 | 2624.39 | 07-JUN-11:20 |
July | 0.934769E+11 | 88480.21 | 22-JUL-15:50 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.960135E+11 | 83797.34 | 14-AUG-13:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.918759E+11 | 80914.52 | 13-SEP-13:30 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.934109E+11 | 70965.77 | 19-OCT-18:40 | 0.671854E+10 | 46499.55 | 23-OCT-08:09 |
November | 0.916615E+11 | 72266.44 | 30-NOV-19:10 | 0.339520E+11 | 109999.20 | 29-NOV-09:09 |
December | 0.951623E+11 | 72264.15 | 27-DEC-16:19 | 0.663506E+11 | 131736.91 | 30-DEC-09:09 |
Annual Sum or Average | 0.110602E+13 | 0.263990E+12 | ||||
Minimum of Months | 0.850732E+11 | 70965.77 | 0.00 | 0.00 | ||
Maximum of Months | 0.960135E+11 | 88480.21 | 0.663506E+11 | 149961.26 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.496324E+11 | 0.120823E+11 | 0.108804E+11 | 0.00 | 0.168432E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.561597E+10 | 0.00 |
February | 0.449372E+11 | 0.994245E+10 | 0.985143E+10 | 0.00 | 0.152480E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.509406E+10 | 0.00 |
March | 0.503750E+11 | 0.967602E+10 | 0.110523E+11 | 0.00 | 0.171289E+11 | 0.00 | 0.00 | 47457.84 | 0.00 | 0.00 | 0.00 | 0.566216E+10 | 0.00 |
April | 0.481627E+11 | 0.801824E+10 | 0.105581E+11 | 0.00 | 0.164635E+11 | 0.00 | 0.00 | 0.468508E+09 | 0.00 | 0.00 | 0.00 | 0.539362E+10 | 0.00 |
May | 0.499854E+11 | 0.710477E+10 | 0.109629E+11 | 0.00 | 0.171623E+11 | 0.00 | 0.00 | 0.308363E+09 | 0.00 | 0.00 | 0.00 | 0.553487E+10 | 0.00 |
June | 0.486922E+11 | 0.624628E+10 | 0.106818E+11 | 0.00 | 0.169302E+11 | 0.00 | 0.00 | 0.241238E+10 | 0.00 | 0.00 | 0.00 | 0.530732E+10 | 0.00 |
July | 0.494924E+11 | 0.673262E+10 | 0.108460E+11 | 0.00 | 0.172143E+11 | 0.00 | 0.00 | 0.379006E+10 | 0.00 | 0.00 | 0.00 | 0.540150E+10 | 0.00 |
August | 0.503385E+11 | 0.776027E+10 | 0.110454E+11 | 0.00 | 0.175394E+11 | 0.00 | 0.00 | 0.388889E+10 | 0.00 | 0.00 | 0.00 | 0.544100E+10 | 0.00 |
September | 0.481992E+11 | 0.877947E+10 | 0.105649E+11 | 0.00 | 0.167466E+11 | 0.00 | 0.00 | 0.233734E+10 | 0.00 | 0.00 | 0.00 | 0.524834E+10 | 0.00 |
October | 0.496324E+11 | 0.104542E+11 | 0.108804E+11 | 0.00 | 0.169584E+11 | 0.00 | 0.00 | 6295350.64 | 0.00 | 0.00 | 0.00 | 0.547926E+10 | 0.00 |
November | 0.480897E+11 | 0.113253E+11 | 0.105443E+11 | 0.00 | 0.163346E+11 | 0.00 | 0.00 | 79644.76 | 0.00 | 0.00 | 0.00 | 0.536744E+10 | 0.00 |
December | 0.495289E+11 | 0.124080E+11 | 0.108529E+11 | 0.00 | 0.167840E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.558856E+10 | 0.00 |
Annual Sum or Average | 0.587066E+12 | 0.110530E+12 | 0.128721E+12 | 0.201353E+12 | 0.00 | 0.132120E+11 | 0.651341E+11 | ||||||
Minimum of Months | 0.449372E+11 | 0.624628E+10 | 0.985143E+10 | 0.00 | 0.152480E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.509406E+10 | 0.00 |
Maximum of Months | 0.503750E+11 | 0.124080E+11 | 0.110523E+11 | 0.00 | 0.175394E+11 | 0.00 | 0.00 | 0.388889E+10 | 0.00 | 0.00 | 0.00 | 0.566216E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.602362E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.474558E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.407278E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.598887E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.252617E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 33869725.02 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.671854E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.339520E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.663506E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.263990E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.663506E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 36581.55 | 01-JAN-11:09 | 7048.38 | 01-JAN-00:10 | 8089.53 | 01-JAN-11:09 | 0.00 | 11684.56 | 05-JAN-16:19 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 36581.55 | 01-FEB-10:09 | 7048.38 | 01-FEB-00:10 | 8089.53 | 01-FEB-10:09 | 0.00 | 11684.56 | 08-FEB-20:19 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 36581.55 | 01-MAR-10:09 | 7048.38 | 01-MAR-00:10 | 8089.53 | 01-MAR-10:09 | 0.00 | 11684.56 | 04-MAR-12:09 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 36581.55 | 01-APR-09:09 | 7048.38 | 01-APR-00:10 | 8089.53 | 01-APR-09:09 | 0.00 | 11684.56 | 02-APR-14:09 | 0.00 | 0.00 | 01-APR-00:10 |
May | 36581.55 | 01-MAY-09:09 | 7048.38 | 01-MAY-00:10 | 8089.53 | 01-MAY-09:09 | 0.00 | 11684.56 | 05-MAY-13:09 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 36581.55 | 01-JUN-09:09 | 7048.38 | 01-JUN-00:10 | 8089.53 | 01-JUN-09:09 | 0.00 | 11684.56 | 13-JUN-12:39 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 36581.55 | 01-JUL-09:09 | 7048.38 | 01-JUL-00:10 | 8089.53 | 01-JUL-09:09 | 0.00 | 11684.56 | 18-JUL-10:20 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 36581.55 | 01-AUG-09:09 | 7048.38 | 01-AUG-00:10 | 8089.53 | 01-AUG-09:09 | 0.00 | 11684.56 | 01-AUG-11:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 36581.55 | 01-SEP-09:09 | 7048.38 | 01-SEP-00:10 | 8089.53 | 01-SEP-09:09 | 0.00 | 11684.56 | 01-SEP-13:30 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 36581.55 | 01-OCT-10:09 | 7048.38 | 01-OCT-00:10 | 8089.53 | 01-OCT-10:09 | 0.00 | 11684.56 | 09-OCT-16:30 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 36581.55 | 01-NOV-09:09 | 7048.38 | 01-NOV-00:10 | 8089.53 | 01-NOV-09:09 | 0.00 | 11684.56 | 01-NOV-11:09 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 36581.55 | 01-DEC-10:09 | 7048.38 | 01-DEC-00:10 | 8089.53 | 01-DEC-10:09 | 0.00 | 11684.56 | 05-DEC-11:30 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 36581.55 | 7048.38 | 8089.53 | 0.00 | 11684.56 | 0.00 | 0.00 | |||||
Maximum of Months | 36581.55 | 7048.38 | 8089.53 | 0.00 | 11684.56 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 11867.03 | 12-JAN-13:50 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 9740.66 | 10-FEB-13:20 | 0.00 |
March | 31.65 | 25-MAR-23:10 | 0.00 | 0.00 | 0.00 | 10351.92 | 20-MAR-11:50 | 0.00 |
April | 17911.30 | 30-APR-14:00 | 0.00 | 0.00 | 0.00 | 9615.76 | 15-APR-12:30 | 0.00 |
May | 15393.61 | 22-MAY-14:00 | 0.00 | 0.00 | 0.00 | 10746.33 | 25-MAY-11:09 | 0.00 |
June | 23915.74 | 13-JUN-16:00 | 0.00 | 0.00 | 0.00 | 9720.95 | 28-JUN-12:39 | 0.00 |
July | 26793.84 | 22-JUL-14:00 | 0.00 | 0.00 | 0.00 | 8868.67 | 03-JUL-13:20 | 0.00 |
August | 22290.82 | 14-AUG-16:00 | 0.00 | 0.00 | 0.00 | 7592.78 | 30-AUG-12:09 | 0.00 |
September | 18515.36 | 13-SEP-14:09 | 0.00 | 0.00 | 0.00 | 9717.13 | 23-SEP-12:20 | 0.00 |
October | 1725.55 | 07-OCT-14:00 | 0.00 | 0.00 | 0.00 | 9720.51 | 04-OCT-12:39 | 0.00 |
November | 70.00 | 08-NOV-23:10 | 0.00 | 0.00 | 0.00 | 8870.22 | 09-NOV-15:50 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 9602.04 | 16-DEC-13:20 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 7592.78 | 0.00 | ||
Maximum of Months | 26793.84 | 0.00 | 0.00 | 0.00 | 11867.03 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 73100.01 | 07-JAN-17:49 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 73099.66 | 22-FEB-17:49 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 72153.62 | 28-MAR-18:49 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 79062.40 | 30-APR-15:20 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 17270.12 | 0.00 |
May | 76817.76 | 22-MAY-15:30 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 13866.88 | 0.00 |
June | 85579.54 | 13-JUN-16:10 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 23769.63 | 0.00 |
July | 88480.21 | 22-JUL-15:50 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 26676.42 | 0.00 |
August | 83797.34 | 14-AUG-13:20 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 20351.98 | 0.00 |
September | 80914.52 | 13-SEP-13:30 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 16968.26 | 0.00 |
October | 70965.77 | 19-OCT-18:40 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 72266.44 | 30-NOV-19:10 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 72264.15 | 27-DEC-16:19 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 70965.77 | 36581.55 | 8089.53 | 0.00 | 0.00 | 11684.56 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 88480.21 | 36581.55 | 8089.53 | 7048.38 | 0.00 | 11684.56 | 0.00 | 0.00 | 26676.42 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 149961.26 | 10-JAN-09:09 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 113105.38 | 13-FEB-09:09 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 95824.29 | 15-MAR-08:09 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 59596.53 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 23318.54 | 17-MAY-08:09 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 2624.39 | 07-JUN-11:20 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 46499.55 | 23-OCT-08:09 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 109999.20 | 29-NOV-09:09 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 131736.91 | 30-DEC-09:09 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 149961.26 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 20.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.50 | 20.54 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.33 | 20.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.06 | 62.33 | 20.73 | 62.33 | 20.73 |
February | 448.00 | 21.05 | 38.67 | 20.49 | 38.67 | 20.49 |
March | 496.00 | 21.10 | 35.17 | 20.64 | 35.17 | 20.64 |
April | 393.17 | 22.00 | 15.33 | 23.34 | 2.67 | 20.75 |
May | 371.33 | 22.28 | 47.83 | 23.89 | 0.00 | 0.00 |
June | 68.17 | 23.19 | 255.83 | 23.90 | 0.00 | 0.00 |
July | 22.50 | 23.61 | 352.50 | 23.92 | 0.00 | 0.00 |
August | 7.33 | 23.94 | 372.83 | 23.90 | 0.00 | 0.00 |
September | 52.67 | 23.48 | 245.83 | 23.89 | 0.00 | 0.00 |
October | 398.00 | 21.94 | 3.33 | 23.81 | 0.00 | 0.00 |
November | 480.00 | 21.15 | 17.17 | 20.69 | 17.17 | 20.69 |
December | 496.00 | 21.04 | 61.50 | 20.61 | 61.50 | 20.61 |
Annual Sum or Average | 3729.17 | 21.48 | 1508.33 | 23.43 | 217.50 | 20.64 |
Minimum of Months | 7.33 | 21.04 | 3.33 | 20.49 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.94 | 372.83 | 23.92 | 62.33 | 20.75 |
Report: ComfortReportSimple55Monthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 496.00 | 21.71 | 11.00 | 20.82 | 11.00 | 20.82 |
February | 448.00 | 21.67 | 2.00 | 20.85 | 2.00 | 20.85 |
March | 496.00 | 21.79 | 1.33 | 20.92 | 1.33 | 20.92 |
April | 333.83 | 22.80 | 14.00 | 23.89 | 0.00 | 0.00 |
May | 285.33 | 22.98 | 53.67 | 23.90 | 0.00 | 0.00 |
June | 22.33 | 23.45 | 292.33 | 23.92 | 0.00 | 0.00 |
July | 7.17 | 23.80 | 374.33 | 23.93 | 0.00 | 0.00 |
August | 1.17 | 23.94 | 390.33 | 23.93 | 0.00 | 0.00 |
September | 22.83 | 23.72 | 274.00 | 23.91 | 0.00 | 0.00 |
October | 327.00 | 22.65 | 15.83 | 23.88 | 0.00 | 0.00 |
November | 480.00 | 21.93 | 2.17 | 20.89 | 2.17 | 20.89 |
December | 496.00 | 21.62 | 8.83 | 20.87 | 8.83 | 20.87 |
Annual Sum or Average | 3415.67 | 22.07 | 1439.83 | 23.87 | 25.33 | 20.85 |
Minimum of Months | 1.17 | 21.62 | 1.33 | 20.82 | 0.00 | 0.00 |
Maximum of Months | 496.00 | 23.94 | 390.33 | 23.93 | 11.00 | 20.92 |
Report: ComfortReportSimple55Monthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.12 | 23.00 | 21.11 | 23.00 | 21.11 |
February | 336.00 | 21.11 | 7.67 | 21.11 | 7.67 | 21.11 |
March | 379.00 | 21.15 | 6.67 | 21.11 | 6.67 | 21.11 |
April | 283.67 | 22.17 | 12.17 | 24.15 | 0.00 | 0.00 |
May | 264.50 | 22.47 | 47.50 | 23.93 | 0.00 | 0.00 |
June | 34.17 | 23.25 | 218.50 | 23.95 | 0.00 | 0.00 |
July | 9.17 | 23.65 | 275.83 | 23.98 | 0.17 | 28.05 |
August | 2.33 | 23.80 | 302.00 | 23.98 | 0.00 | 0.00 |
September | 29.50 | 23.37 | 200.17 | 23.95 | 0.00 | 0.00 |
October | 284.17 | 21.98 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 360.00 | 21.20 | 3.83 | 21.11 | 3.83 | 21.11 |
December | 369.00 | 21.11 | 22.50 | 21.11 | 22.50 | 21.11 |
Annual Sum or Average | 2722.50 | 21.53 | 1119.83 | 23.81 | 63.83 | 21.13 |
Minimum of Months | 2.33 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 23.80 | 302.00 | 24.15 | 23.00 | 28.05 |
Report: ComfortReportSimple55Monthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 32.00 | 21.11 | 32.00 | 21.11 |
February | 336.00 | 21.11 | 14.17 | 21.11 | 14.17 | 21.11 |
March | 379.00 | 21.13 | 11.50 | 21.10 | 11.50 | 21.10 |
April | 292.33 | 22.05 | 10.00 | 24.20 | 0.00 | 0.00 |
May | 277.00 | 22.33 | 43.67 | 23.93 | 0.00 | 0.00 |
June | 43.17 | 23.22 | 211.00 | 23.95 | 0.00 | 0.00 |
July | 10.83 | 23.59 | 271.67 | 23.98 | 0.17 | 28.04 |
August | 2.50 | 23.79 | 299.17 | 23.98 | 0.00 | 0.00 |
September | 32.33 | 23.34 | 190.33 | 23.94 | 0.00 | 0.00 |
October | 290.33 | 21.86 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 360.00 | 21.17 | 6.33 | 21.11 | 6.33 | 21.11 |
December | 369.00 | 21.11 | 34.50 | 21.11 | 34.50 | 21.11 |
Annual Sum or Average | 2763.50 | 21.49 | 1124.33 | 23.72 | 98.67 | 21.12 |
Minimum of Months | 2.50 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 23.79 | 299.17 | 24.20 | 34.50 | 28.04 |
Report: ComfortReportSimple55Monthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 371.00 | 21.11 | 44.00 | 21.11 | 44.00 | 21.11 |
February | 336.00 | 21.11 | 21.33 | 21.11 | 21.33 | 21.11 |
March | 379.00 | 21.12 | 18.17 | 21.11 | 18.17 | 21.11 |
April | 300.00 | 21.92 | 8.67 | 24.08 | 0.50 | 21.11 |
May | 292.67 | 22.19 | 39.50 | 23.92 | 0.00 | 0.00 |
June | 55.67 | 23.15 | 194.33 | 23.95 | 0.00 | 0.00 |
July | 13.83 | 23.49 | 261.50 | 23.98 | 0.17 | 27.99 |
August | 4.67 | 23.74 | 290.33 | 23.98 | 0.00 | 0.00 |
September | 37.67 | 23.28 | 178.83 | 23.94 | 0.00 | 0.00 |
October | 299.67 | 21.77 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 360.00 | 21.15 | 10.00 | 21.11 | 10.00 | 21.11 |
December | 369.00 | 21.11 | 46.83 | 21.11 | 46.83 | 21.11 |
Annual Sum or Average | 2819.17 | 21.47 | 1113.50 | 23.60 | 141.00 | 21.12 |
Minimum of Months | 4.67 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 379.00 | 23.74 | 290.33 | 24.08 | 46.83 | 27.99 |
Report: ComfortReportSimple55Monthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 72.67 | 21.11 | 72.67 | 21.11 |
February | 308.00 | 21.11 | 25.50 | 21.11 | 25.50 | 21.11 |
March | 348.00 | 21.11 | 24.67 | 21.11 | 24.67 | 21.11 |
April | 289.00 | 21.74 | 5.67 | 23.80 | 1.17 | 21.11 |
May | 277.83 | 21.91 | 26.17 | 23.89 | 0.00 | 0.00 |
June | 77.33 | 22.99 | 140.33 | 23.89 | 0.00 | 0.00 |
July | 27.50 | 23.33 | 224.33 | 23.92 | 0.00 | 0.00 |
August | 5.00 | 23.74 | 255.33 | 23.92 | 0.00 | 0.00 |
September | 35.50 | 23.26 | 149.33 | 23.91 | 0.00 | 0.00 |
October | 291.33 | 21.66 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 330.00 | 21.12 | 13.33 | 21.11 | 13.33 | 21.11 |
December | 338.00 | 21.11 | 68.33 | 21.11 | 68.33 | 21.11 |
Annual Sum or Average | 2667.50 | 21.43 | 1005.67 | 23.34 | 205.67 | 21.11 |
Minimum of Months | 5.00 | 21.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.74 | 255.33 | 23.92 | 72.67 | 21.11 |
Report: ComfortReportSimple55Monthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 76.33 | 21.11 | 76.33 | 21.11 |
February | 308.00 | 21.11 | 29.50 | 21.11 | 29.50 | 21.11 |
March | 348.00 | 21.11 | 31.17 | 21.11 | 31.17 | 21.11 |
April | 292.33 | 21.74 | 3.50 | 23.02 | 2.00 | 21.11 |
May | 280.67 | 21.90 | 16.83 | 23.89 | 0.00 | 0.00 |
June | 90.83 | 23.04 | 107.67 | 23.90 | 0.00 | 0.00 |
July | 32.33 | 23.36 | 203.50 | 23.93 | 0.00 | 0.00 |
August | 6.83 | 23.76 | 235.17 | 23.92 | 0.00 | 0.00 |
September | 39.67 | 23.32 | 132.67 | 23.91 | 0.00 | 0.00 |
October | 296.67 | 21.69 | 0.33 | 21.12 | 0.33 | 21.12 |
November | 330.00 | 21.12 | 15.17 | 21.11 | 15.17 | 21.11 |
December | 338.00 | 21.11 | 72.83 | 21.11 | 72.83 | 21.11 |
Annual Sum or Average | 2703.33 | 21.46 | 924.67 | 23.23 | 227.33 | 21.11 |
Minimum of Months | 6.83 | 21.11 | 0.33 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.76 | 235.17 | 23.93 | 76.33 | 21.12 |
Report: ComfortReportSimple55Monthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 83.17 | 21.11 | 83.17 | 21.11 |
February | 308.00 | 21.11 | 33.50 | 21.11 | 33.50 | 21.11 |
March | 348.00 | 21.11 | 35.00 | 21.11 | 35.00 | 21.11 |
April | 294.17 | 21.68 | 4.50 | 22.58 | 3.00 | 21.11 |
May | 283.33 | 21.84 | 14.33 | 23.89 | 0.00 | 0.00 |
June | 101.00 | 22.96 | 93.50 | 23.91 | 0.00 | 0.00 |
July | 38.17 | 23.31 | 196.50 | 23.93 | 0.00 | 0.00 |
August | 9.67 | 23.73 | 227.67 | 23.92 | 0.00 | 0.00 |
September | 46.83 | 23.30 | 125.33 | 23.91 | 0.00 | 0.00 |
October | 306.00 | 21.70 | 0.50 | 21.12 | 0.50 | 21.12 |
November | 330.00 | 21.12 | 18.00 | 21.11 | 18.00 | 21.11 |
December | 338.00 | 21.11 | 80.50 | 21.11 | 80.50 | 21.11 |
Annual Sum or Average | 2743.17 | 21.46 | 912.50 | 23.14 | 253.67 | 21.11 |
Minimum of Months | 9.67 | 21.11 | 0.50 | 21.11 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.73 | 227.67 | 23.93 | 83.17 | 21.12 |
Report: ComfortReportSimple55Monthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 106.17 | 21.11 | 106.17 | 21.11 |
February | 308.00 | 21.11 | 45.83 | 21.10 | 45.83 | 21.10 |
March | 348.00 | 21.11 | 47.83 | 21.11 | 47.83 | 21.11 |
April | 303.00 | 21.61 | 7.33 | 21.91 | 6.00 | 21.11 |
May | 292.33 | 21.72 | 7.83 | 23.83 | 0.17 | 21.11 |
June | 135.67 | 22.82 | 71.50 | 23.90 | 0.00 | 0.00 |
July | 53.33 | 23.18 | 180.83 | 23.93 | 0.00 | 0.00 |
August | 17.50 | 23.66 | 215.33 | 23.92 | 0.00 | 0.00 |
September | 65.00 | 23.21 | 106.83 | 23.91 | 0.00 | 0.00 |
October | 331.50 | 21.72 | 1.50 | 21.12 | 1.50 | 21.12 |
November | 330.00 | 21.11 | 26.00 | 21.11 | 26.00 | 21.11 |
December | 338.00 | 21.11 | 113.33 | 21.10 | 113.33 | 21.10 |
Annual Sum or Average | 2862.33 | 21.48 | 930.33 | 22.87 | 346.83 | 21.11 |
Minimum of Months | 17.50 | 21.11 | 1.50 | 21.10 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.66 | 215.33 | 23.93 | 113.33 | 21.12 |
Report: ComfortReportSimple55Monthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 340.00 | 21.11 | 179.67 | 21.10 | 179.67 | 21.10 |
February | 308.00 | 21.11 | 129.17 | 21.10 | 129.17 | 21.10 |
March | 348.00 | 21.11 | 134.83 | 21.10 | 134.83 | 21.10 |
April | 309.33 | 21.49 | 23.00 | 21.25 | 22.33 | 21.11 |
May | 308.33 | 21.57 | 10.00 | 22.37 | 5.50 | 21.13 |
June | 216.17 | 22.62 | 39.33 | 23.93 | 0.00 | 0.00 |
July | 93.83 | 23.01 | 138.33 | 23.93 | 0.00 | 0.00 |
August | 44.33 | 23.48 | 185.00 | 23.92 | 0.00 | 0.00 |
September | 131.00 | 23.05 | 74.00 | 23.92 | 0.00 | 0.00 |
October | 340.00 | 21.56 | 11.17 | 21.13 | 11.17 | 21.13 |
November | 330.00 | 21.11 | 77.83 | 21.10 | 77.83 | 21.10 |
December | 338.00 | 21.11 | 238.33 | 21.10 | 238.33 | 21.10 |
Annual Sum or Average | 3107.00 | 21.52 | 1240.67 | 22.11 | 798.83 | 21.10 |
Minimum of Months | 44.33 | 21.11 | 10.00 | 21.10 | 0.00 | 0.00 |
Maximum of Months | 348.00 | 23.48 | 238.33 | 23.93 | 238.33 | 21.13 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.05829 | 31.22175 | -0.4249 | 9.03703 |
February | 448.00000 | 21.04838 | 32.26388 | -0.4127 | 8.74102 |
March | 496.00000 | 21.09335 | 32.31303 | -0.3965 | 8.46909 |
April | 480.00000 | 22.34436 | 31.15897 | -0.0443 | 6.57691 |
May | 496.00000 | 22.68088 | 36.68814 | -0.9285 | 25.35729 |
June | 480.00000 | 23.77911 | 42.94657 | -0.4887 | 10.48854 |
July | 496.00000 | 23.89640 | 44.34645 | -0.4138 | 8.81531 |
August | 496.00000 | 23.91872 | 44.79671 | -0.4019 | 8.52627 |
September | 480.00000 | 23.84270 | 41.78548 | -0.4678 | 9.93537 |
October | 496.00000 | 22.31270 | 39.50915 | -0.0122 | 6.33357 |
November | 480.00000 | 21.14974 | 36.34185 | -0.3450 | 7.69341 |
December | 496.00000 | 21.03833 | 30.39973 | -0.4512 | 9.43638 |
Annual Sum or Average | 5840.00000 | 22.35285 | 37.00794 | -0.3995 | 9.97479 |
Minimum of Months | 448.00000 | 21.03833 | 30.39973 | -0.9285 | 6.33357 |
Maximum of Months | 496.00000 | 23.91872 | 44.79671 | -0.0122 | 25.35729 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 496.00000 | 21.68708 | 32.15400 | -0.2691 | 7.19023 |
February | 448.00000 | 21.65146 | 33.10670 | -0.2640 | 6.95539 |
March | 496.00000 | 21.76663 | 32.81536 | -0.2365 | 6.82661 |
April | 480.00000 | 23.11317 | 30.60261 | 0.12206 | 6.27899 |
May | 496.00000 | 23.35305 | 35.69907 | -0.7245 | 17.20398 |
June | 480.00000 | 23.89680 | 42.55387 | -0.4454 | 9.36805 |
July | 496.00000 | 23.93049 | 44.10540 | -0.4005 | 8.50540 |
August | 496.00000 | 23.93334 | 44.60824 | -0.3929 | 8.34586 |
September | 480.00000 | 23.90395 | 41.56678 | -0.4417 | 9.27341 |
October | 496.00000 | 23.05016 | 38.59355 | 0.14586 | 6.32385 |
November | 480.00000 | 21.90916 | 36.38750 | -0.1756 | 6.35259 |
December | 496.00000 | 21.60014 | 31.32633 | -0.3072 | 7.48744 |
Annual Sum or Average | 5840.00000 | 22.82159 | 36.98266 | -0.2831 | 8.35980 |
Minimum of Months | 448.00000 | 21.60014 | 30.60261 | -0.7245 | 6.27899 |
Maximum of Months | 496.00000 | 23.93334 | 44.60824 | 0.14586 | 17.20398 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.12356 | 31.14908 | -0.3983 | 8.47778 |
February | 336.00000 | 21.11386 | 32.40690 | -0.3823 | 8.13298 |
March | 379.00000 | 21.15540 | 31.68030 | -0.3721 | 7.99846 |
April | 360.00000 | 22.55093 | 30.22126 | 0.00330 | 6.46618 |
May | 375.00000 | 22.89198 | 36.00000 | -0.8560 | 22.29348 |
June | 366.00000 | 23.85960 | 42.49366 | -0.4606 | 9.80634 |
July | 369.00000 | 23.95570 | 44.20700 | -0.3937 | 8.47730 |
August | 379.00000 | 23.97051 | 44.68416 | -0.3810 | 8.20088 |
September | 360.00000 | 23.88570 | 41.72487 | -0.4470 | 9.50411 |
October | 371.00000 | 22.42965 | 39.15629 | 0.01786 | 6.27985 |
November | 360.00000 | 21.20852 | 36.15313 | -0.3244 | 7.36924 |
December | 369.00000 | 21.10755 | 30.19674 | -0.4253 | 8.86148 |
Annual Sum or Average | 4395.00000 | 22.44662 | 36.70934 | -0.3694 | 9.35079 |
Minimum of Months | 336.00000 | 21.10755 | 30.19674 | -0.8560 | 6.27985 |
Maximum of Months | 379.00000 | 23.97051 | 44.68416 | 0.01786 | 22.29348 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.11083 | 31.17532 | -0.4141 | 8.74662 |
February | 336.00000 | 21.10796 | 32.41734 | -0.3954 | 8.35213 |
March | 379.00000 | 21.13458 | 31.72103 | -0.3877 | 8.24088 |
April | 360.00000 | 22.40880 | 30.47056 | -0.0357 | 6.55961 |
May | 375.00000 | 22.74439 | 36.31387 | -0.9103 | 24.54956 |
June | 366.00000 | 23.83708 | 42.56162 | -0.4728 | 10.10007 |
July | 369.00000 | 23.94821 | 44.23239 | -0.3996 | 8.59365 |
August | 379.00000 | 23.96759 | 44.70022 | -0.3847 | 8.25891 |
September | 360.00000 | 23.87554 | 41.76389 | -0.4547 | 9.67060 |
October | 371.00000 | 22.30344 | 39.47209 | -0.0177 | 6.36356 |
November | 360.00000 | 21.17089 | 36.24088 | -0.3444 | 7.62794 |
December | 369.00000 | 21.10359 | 30.20269 | -0.4388 | 9.11607 |
Annual Sum or Average | 4395.00000 | 22.40141 | 36.80978 | -0.3891 | 9.71380 |
Minimum of Months | 336.00000 | 21.10359 | 30.20269 | -0.9103 | 6.36356 |
Maximum of Months | 379.00000 | 23.96759 | 44.70022 | -0.0177 | 24.54956 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 371.00000 | 21.10372 | 31.19139 | -0.4276 | 8.99531 |
February | 336.00000 | 21.10397 | 32.42642 | -0.4072 | 8.56132 |
March | 379.00000 | 21.12143 | 31.74816 | -0.4011 | 8.46341 |
April | 360.00000 | 22.25941 | 30.74053 | -0.0763 | 6.65018 |
May | 375.00000 | 22.56987 | 36.69256 | -0.9733 | 27.23316 |
June | 366.00000 | 23.79086 | 42.70580 | -0.4952 | 10.66511 |
July | 369.00000 | 23.93211 | 44.30211 | -0.4111 | 8.82374 |
August | 379.00000 | 23.95981 | 44.75442 | -0.3933 | 8.40561 |
September | 360.00000 | 23.85519 | 41.84209 | -0.4679 | 9.97086 |
October | 371.00000 | 22.17932 | 39.78862 | -0.0523 | 6.43835 |
November | 360.00000 | 21.14735 | 36.29703 | -0.3597 | 7.84324 |
December | 369.00000 | 21.10018 | 30.21022 | -0.4522 | 9.37911 |
Annual Sum or Average | 4395.00000 | 22.35201 | 36.92949 | -0.4110 | 10.15602 |
Minimum of Months | 336.00000 | 21.10018 | 30.21022 | -0.9733 | 6.43835 |
Maximum of Months | 379.00000 | 23.95981 | 44.75442 | -0.0523 | 27.23316 |
Report: OccupantComfortDataSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.09314 | 32.15007 | -0.4564 | 9.54908 |
February | 308.00000 | 21.09589 | 33.29490 | -0.4325 | 9.00790 |
March | 348.00000 | 21.10251 | 32.62934 | -0.4276 | 8.92140 |
April | 330.00000 | 22.01482 | 31.97582 | -0.1352 | 6.82102 |
May | 344.00000 | 22.29234 | 38.11644 | -1.0657 | 31.28755 |
June | 336.00000 | 23.64979 | 43.85888 | -0.5453 | 11.96402 |
July | 338.00000 | 23.86737 | 45.08194 | -0.4357 | 9.30002 |
August | 348.00000 | 23.91642 | 45.35715 | -0.4117 | 8.69051 |
September | 330.00000 | 23.81996 | 42.67631 | -0.4852 | 10.28882 |
October | 340.00000 | 21.97534 | 41.17762 | -0.1057 | 6.57082 |
November | 330.00000 | 21.11378 | 37.28534 | -0.3880 | 8.26663 |
December | 338.00000 | 21.08981 | 31.10649 | -0.4860 | 10.05616 |
Annual Sum or Average | 4030.00000 | 22.26076 | 37.93182 | -0.4493 | 10.93886 |
Minimum of Months | 308.00000 | 21.08981 | 31.10649 | -1.0657 | 6.57082 |
Maximum of Months | 348.00000 | 23.91642 | 45.35715 | -0.1057 | 31.28755 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.09227 | 32.11125 | -0.4621 | 9.65582 |
February | 308.00000 | 21.09502 | 33.25924 | -0.4395 | 9.13613 |
March | 348.00000 | 21.10179 | 32.58913 | -0.4352 | 9.05935 |
April | 330.00000 | 21.99085 | 31.96802 | -0.1553 | 6.89943 |
May | 344.00000 | 22.27071 | 38.11092 | -1.0943 | 32.52452 |
June | 336.00000 | 23.63878 | 43.85219 | -0.5709 | 12.59951 |
July | 338.00000 | 23.86477 | 45.06933 | -0.4587 | 9.72914 |
August | 348.00000 | 23.91537 | 45.34901 | -0.4332 | 9.06494 |
September | 330.00000 | 23.82437 | 42.63114 | -0.5041 | 10.66182 |
October | 340.00000 | 21.97142 | 41.13496 | -0.1187 | 6.60841 |
November | 330.00000 | 21.11417 | 37.23898 | -0.3951 | 8.38208 |
December | 338.00000 | 21.08978 | 31.06803 | -0.4898 | 10.13658 |
Annual Sum or Average | 4030.00000 | 22.25558 | 37.90460 | -0.4645 | 11.25280 |
Minimum of Months | 308.00000 | 21.08978 | 31.06803 | -1.0943 | 6.60841 |
Maximum of Months | 348.00000 | 23.91537 | 45.34901 | -0.1187 | 32.52452 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.09059 | 32.11388 | -0.4684 | 9.78527 |
February | 308.00000 | 21.09303 | 33.26253 | -0.4460 | 9.26280 |
March | 348.00000 | 21.09934 | 32.59404 | -0.4416 | 9.17947 |
April | 330.00000 | 21.92677 | 32.09282 | -0.1744 | 6.99235 |
May | 344.00000 | 22.19983 | 38.27254 | -1.1234 | 33.83522 |
June | 336.00000 | 23.58219 | 44.02378 | -0.5958 | 13.34207 |
July | 338.00000 | 23.84740 | 45.13763 | -0.4704 | 10.00854 |
August | 348.00000 | 23.91201 | 45.37896 | -0.4396 | 9.18464 |
September | 330.00000 | 23.80627 | 42.70008 | -0.5156 | 10.94531 |
October | 340.00000 | 21.91246 | 41.28440 | -0.1365 | 6.63544 |
November | 330.00000 | 21.11004 | 37.24860 | -0.4011 | 8.48543 |
December | 338.00000 | 21.08756 | 31.07192 | -0.4960 | 10.26941 |
Annual Sum or Average | 4030.00000 | 22.23033 | 37.97150 | -0.4772 | 11.54405 |
Minimum of Months | 308.00000 | 21.08756 | 31.07192 | -1.1234 | 6.63544 |
Maximum of Months | 348.00000 | 23.91201 | 45.37896 | -0.1365 | 33.83522 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.08425 | 32.12403 | -0.4867 | 10.17500 |
February | 308.00000 | 21.08630 | 33.27416 | -0.4650 | 9.64905 |
March | 348.00000 | 21.09229 | 32.60658 | -0.4598 | 9.54244 |
April | 330.00000 | 21.79784 | 32.34767 | -0.2132 | 7.26356 |
May | 344.00000 | 22.04444 | 38.62908 | -1.1859 | 36.69842 |
June | 336.00000 | 23.42746 | 44.48141 | -0.6573 | 15.28859 |
July | 338.00000 | 23.79224 | 45.33871 | -0.4996 | 10.77208 |
August | 348.00000 | 23.89999 | 45.46825 | -0.4541 | 9.47807 |
September | 330.00000 | 23.74079 | 42.92207 | -0.5478 | 11.80938 |
October | 340.00000 | 21.77499 | 41.61786 | -0.1771 | 6.73363 |
November | 330.00000 | 21.10012 | 37.27158 | -0.4177 | 8.78143 |
December | 338.00000 | 21.08091 | 31.08324 | -0.5142 | 10.67556 |
Annual Sum or Average | 4030.00000 | 22.16796 | 38.13750 | -0.5080 | 12.29341 |
Minimum of Months | 308.00000 | 21.08091 | 31.08324 | -1.1859 | 6.73363 |
Maximum of Months | 348.00000 | 23.89999 | 45.46825 | -0.1771 | 36.69842 |
Report: OccupantComfortDataSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 340.00000 | 21.06897 | 32.11421 | -0.5509 | 11.64706 |
February | 308.00000 | 21.06839 | 33.21785 | -0.5327 | 11.14170 |
March | 348.00000 | 21.07279 | 32.56680 | -0.5255 | 10.97609 |
April | 330.00000 | 21.63336 | 32.57243 | -0.2841 | 8.03691 |
May | 344.00000 | 21.79295 | 39.07275 | -1.3106 | 42.58445 |
June | 336.00000 | 23.05802 | 45.36408 | -0.8024 | 20.38698 |
July | 338.00000 | 23.65244 | 45.68963 | -0.5725 | 12.86837 |
August | 348.00000 | 23.84872 | 45.63219 | -0.4995 | 10.52799 |
September | 330.00000 | 23.53481 | 43.32713 | -0.6395 | 14.60883 |
October | 340.00000 | 21.55226 | 41.97362 | -0.2622 | 7.31891 |
November | 330.00000 | 21.08146 | 37.15862 | -0.4747 | 9.91380 |
December | 338.00000 | 21.06585 | 30.96278 | -0.5776 | 12.19505 |
Annual Sum or Average | 4030.00000 | 22.04328 | 38.34622 | -0.5876 | 14.41158 |
Minimum of Months | 308.00000 | 21.06585 | 30.96278 | -1.3106 | 7.31891 |
Maximum of Months | 348.00000 | 23.84872 | 45.68963 | -0.2622 | 42.58445 |
Report: DXReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.458726E+09 | 0.121000E+09 | 50.82 | 0.456909E+09 | 1817019.49 | 0.00 | 0.53 | 30-APR-16:15 | 0.00 | 01-APR-00:05 | 12290.97 | 30-APR-16:15 | 12290.97 | 30-APR-16:15 | 434.96 | 29-APR-08:62 | 3182.08 | 30-APR-16:15 | 0.00 | 01-APR-00:05 |
May | 0.284700E+09 | 76449345.15 | 64.19 | 0.249497E+09 | 35203048.69 | 0.00 | 0.76 | 23-MAY-08:62 | 0.00 | 01-MAY-00:10 | 19341.70 | 23-MAY-08:62 | 14610.01 | 23-MAY-08:62 | 4731.70 | 23-MAY-08:62 | 4454.50 | 23-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.185527E+10 | 0.480700E+09 | 203.67 | 0.157117E+10 | 0.284094E+09 | 0.00 | 1.00 | 12-JUN-08:62 | 0.00 | 01-JUN-00:10 | 28324.80 | 13-JUN-08:62 | 23920.03 | 13-JUN-08:62 | 12385.98 | 27-JUN-08:62 | 6027.41 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.307410E+10 | 0.812339E+09 | 276.97 | 0.267543E+10 | 0.398668E+09 | 0.00 | 1.00 | 07-JUL-08:62 | 0.00 | 01-JUL-00:10 | 28482.36 | 18-JUL-08:62 | 26507.03 | 22-JUL-08:61 | 11087.44 | 25-JUL-08:62 | 6287.15 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.295331E+10 | 0.779608E+09 | 321.01 | 0.248604E+10 | 0.467276E+09 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 28562.34 | 17-AUG-08:62 | 24172.83 | 22-AUG-08:62 | 11454.47 | 17-AUG-08:62 | 6072.45 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.178412E+10 | 0.466632E+09 | 234.98 | 0.152522E+10 | 0.258902E+09 | 0.00 | 1.00 | 02-SEP-08:62 | 0.00 | 01-SEP-00:10 | 28284.62 | 11-SEP-08:62 | 22455.55 | 14-SEP-08:62 | 10100.20 | 16-SEP-08:62 | 6019.56 | 11-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 2883034.34 | 804429.82 | 32.13 | 2882095.54 | 938.79 | 0.00 | 0.07 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 | 1379.77 | 07-OCT-15:00 | 1379.77 | 07-OCT-15:00 | 0.10 | 08-OCT-17:09 | 382.84 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.104131E+11 | 0.273753E+10 | 1183.78 | 0.896715E+10 | 0.144596E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.307410E+10 | 0.812339E+09 | 321.01 | 0.267543E+10 | 0.467276E+09 | 0.00 | 1.00 | 0.00 | 28562.34 | 26507.03 | 12385.98 | 6287.15 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 160322.48 | 47457.84 | 0.83 | 148832.45 | 11490.03 | 0.00 | 0.01 | 25-MAR-23:10 | 0.00 | 01-MAR-00:10 | 106.85 | 25-MAR-23:10 | 98.59 | 25-MAR-23:10 | 10.89 | 19-MAR-22:10 | 31.65 | 25-MAR-23:10 | 0.00 | 01-MAR-00:10 |
April | 0.309039E+09 | 77655158.30 | 61.28 | 0.305112E+09 | 3926819.45 | 0.00 | 1.00 | 20-APR-20:02 | 0.00 | 01-APR-00:05 | 15009.78 | 30-APR-19:02 | 15009.78 | 30-APR-19:02 | 1928.51 | 30-APR-20:30 | 3189.46 | 30-APR-19:02 | 0.00 | 01-APR-00:05 |
May | 0.223522E+09 | 56730918.22 | 70.87 | 0.198925E+09 | 24597230.39 | 0.00 | 1.00 | 21-MAY-17:01 | 0.00 | 01-MAY-00:10 | 15356.24 | 23-MAY-08:62 | 14875.30 | 21-MAY-17:06 | 3706.54 | 23-MAY-08:62 | 3175.86 | 23-MAY-08:62 | 0.00 | 01-MAY-00:10 |
June | 0.111055E+10 | 0.276288E+09 | 182.79 | 0.940067E+09 | 0.170481E+09 | 0.00 | 1.00 | 05-JUN-08:62 | 0.00 | 01-JUN-00:10 | 16549.11 | 25-JUN-18:00 | 13675.84 | 25-JUN-17:02 | 6774.34 | 27-JUN-08:62 | 3406.20 | 25-JUN-18:00 | 0.00 | 01-JUN-00:10 |
July | 0.182363E+10 | 0.457901E+09 | 229.78 | 0.157611E+10 | 0.247522E+09 | 0.00 | 1.00 | 07-JUL-08:62 | 0.00 | 01-JUL-00:10 | 15920.28 | 23-JUL-17:02 | 14734.74 | 22-JUL-08:61 | 6086.98 | 25-JUL-08:62 | 3380.89 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.188942E+10 | 0.474251E+09 | 267.53 | 0.157961E+10 | 0.309813E+09 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 15821.39 | 17-AUG-08:62 | 14804.24 | 14-AUG-20:07 | 6345.63 | 17-AUG-08:03 | 3266.26 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.109839E+10 | 0.276086E+09 | 195.40 | 0.939029E+09 | 0.159366E+09 | 0.00 | 1.00 | 01-SEP-08:62 | 0.00 | 01-SEP-00:10 | 15814.80 | 10-SEP-17:02 | 14767.38 | 27-SEP-22:22 | 5522.35 | 15-SEP-08:62 | 3265.08 | 10-SEP-17:02 | 0.00 | 01-SEP-00:10 |
October | 12846659.43 | 3451784.86 | 48.03 | 12444485.56 | 402173.87 | 0.00 | 1.00 | 01-OCT-18:47 | 0.00 | 01-OCT-00:05 | 14680.22 | 01-OCT-18:47 | 14642.44 | 07-OCT-20:51 | 270.09 | 08-OCT-22:10 | 3020.14 | 01-OCT-18:47 | 0.00 | 01-OCT-00:05 |
November | 269378.35 | 79644.76 | 0.67 | 236651.43 | 32726.92 | 0.00 | 0.02 | 08-NOV-23:10 | 0.00 | 01-NOV-00:10 | 237.05 | 08-NOV-23:10 | 200.34 | 08-NOV-23:10 | 36.71 | 08-NOV-23:10 | 70.00 | 08-NOV-23:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.646783E+10 | 0.162249E+10 | 1057.17 | 0.555168E+10 | 0.916153E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.188942E+10 | 0.474251E+09 | 267.53 | 0.157961E+10 | 0.309813E+09 | 0.00 | 1.00 | 0.00 | 16549.11 | 15009.78 | 6774.34 | 3406.20 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.160063E+09 | 41105559.90 | 40.88 | 0.158457E+09 | 1605635.84 | 0.00 | 1.00 | 30-APR-08:62 | 0.00 | 01-APR-00:05 | 14673.41 | 30-APR-08:62 | 13409.57 | 30-APR-08:62 | 2149.70 | 22-APR-07:01 | 3026.03 | 30-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.135134E+09 | 34919396.81 | 48.36 | 0.117538E+09 | 17595529.49 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 14816.49 | 23-MAY-07:02 | 12359.67 | 01-MAY-07:01 | 4281.05 | 26-MAY-07:01 | 3059.65 | 23-MAY-07:02 | 0.00 | 01-MAY-00:10 |
June | 0.891496E+09 | 0.224600E+09 | 166.81 | 0.761203E+09 | 0.130294E+09 | 0.00 | 1.00 | 03-JUN-07:01 | 0.00 | 01-JUN-00:10 | 15526.83 | 27-JUN-07:02 | 13050.34 | 26-JUN-07:02 | 6821.74 | 27-JUN-07:02 | 3207.57 | 27-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.135146E+10 | 0.346996E+09 | 210.70 | 0.118011E+10 | 0.171347E+09 | 0.00 | 1.00 | 01-JUL-07:02 | 0.00 | 01-JUL-00:10 | 15528.86 | 18-JUL-07:02 | 14040.48 | 22-JUL-07:02 | 6014.74 | 25-JUL-07:02 | 3296.88 | 22-JUL-07:02 | 0.00 | 01-JUL-00:10 |
August | 0.146600E+10 | 0.375603E+09 | 249.64 | 0.123173E+10 | 0.234273E+09 | 0.00 | 1.00 | 01-AUG-07:03 | 0.00 | 01-AUG-00:10 | 15429.61 | 17-AUG-07:02 | 12980.95 | 15-AUG-07:02 | 6251.78 | 17-AUG-07:02 | 3189.32 | 17-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.896244E+09 | 0.227717E+09 | 173.23 | 0.770774E+09 | 0.125470E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 15239.94 | 16-SEP-07:02 | 12728.53 | 30-SEP-07:01 | 6015.43 | 16-SEP-07:02 | 3151.82 | 16-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 2750707.98 | 728215.96 | 34.18 | 2659930.75 | 90777.24 | 0.00 | 0.49 | 02-OCT-07:01 | 0.00 | 01-OCT-00:05 | 6041.78 | 02-OCT-07:01 | 5113.69 | 02-OCT-07:01 | 928.10 | 02-OCT-07:01 | 1453.72 | 02-OCT-07:01 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.490314E+10 | 0.125167E+10 | 923.80 | 0.422247E+10 | 0.680675E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.146600E+10 | 0.375603E+09 | 249.64 | 0.123173E+10 | 0.234273E+09 | 0.00 | 1.00 | 0.00 | 15528.86 | 14040.48 | 6821.74 | 3296.88 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.151746E+09 | 39033908.90 | 38.03 | 0.150522E+09 | 1224187.92 | 0.00 | 1.00 | 30-APR-08:62 | 0.00 | 01-APR-00:05 | 14606.03 | 30-APR-08:62 | 13337.94 | 30-APR-08:62 | 1493.68 | 29-APR-07:02 | 3012.05 | 30-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 0.118779E+09 | 30811259.85 | 46.97 | 0.103717E+09 | 15061534.51 | 0.00 | 1.00 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 14384.41 | 24-MAY-07:01 | 12301.63 | 01-MAY-07:01 | 4275.06 | 26-MAY-07:01 | 2957.62 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 |
June | 0.870076E+09 | 0.219503E+09 | 161.76 | 0.742947E+09 | 0.127130E+09 | 0.00 | 1.00 | 05-JUN-07:02 | 0.00 | 01-JUN-00:10 | 15457.35 | 27-JUN-07:02 | 12987.45 | 26-JUN-07:02 | 6797.11 | 27-JUN-07:02 | 3193.24 | 27-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.132942E+10 | 0.341438E+09 | 208.52 | 0.116096E+10 | 0.168466E+09 | 0.00 | 1.00 | 07-JUL-07:02 | 0.00 | 01-JUL-00:10 | 15458.90 | 18-JUL-07:02 | 13973.05 | 22-JUL-07:02 | 5988.94 | 25-JUL-07:02 | 3282.17 | 22-JUL-07:02 | 0.00 | 01-JUL-00:10 |
August | 0.143690E+10 | 0.368202E+09 | 248.27 | 0.120774E+10 | 0.229156E+09 | 0.00 | 1.00 | 01-AUG-07:03 | 0.00 | 01-AUG-00:10 | 15360.73 | 17-AUG-07:02 | 12921.10 | 15-AUG-07:02 | 6228.87 | 17-AUG-07:02 | 3175.09 | 17-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.869465E+09 | 0.221185E+09 | 170.29 | 0.748425E+09 | 0.121040E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 15170.72 | 16-SEP-07:02 | 12360.98 | 30-SEP-07:01 | 5997.68 | 16-SEP-07:02 | 3137.51 | 16-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 1870217.27 | 505000.98 | 32.23 | 1844973.39 | 25243.88 | 0.00 | 0.17 | 02-OCT-07:01 | 0.00 | 01-OCT-00:05 | 1889.28 | 02-OCT-07:01 | 1596.39 | 02-OCT-07:01 | 292.89 | 02-OCT-07:01 | 496.22 | 02-OCT-07:01 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.477826E+10 | 0.122068E+10 | 906.08 | 0.411615E+10 | 0.662102E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.143690E+10 | 0.368202E+09 | 248.27 | 0.120774E+10 | 0.229156E+09 | 0.00 | 1.00 | 0.00 | 15458.90 | 13973.05 | 6797.11 | 3282.17 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.138542E+09 | 35767289.24 | 34.17 | 0.137622E+09 | 920004.20 | 0.00 | 0.92 | 30-APR-08:62 | 0.00 | 01-APR-00:05 | 13110.07 | 30-APR-08:62 | 11951.13 | 30-APR-08:62 | 1158.94 | 30-APR-08:62 | 2776.18 | 30-APR-08:62 | 0.00 | 01-APR-00:05 |
May | 95745791.22 | 25036886.15 | 45.28 | 84463309.86 | 11282481.35 | 0.00 | 0.88 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 | 12256.51 | 01-MAY-07:01 | 10466.66 | 01-MAY-07:01 | 3243.23 | 24-MAY-07:01 | 2618.70 | 01-MAY-07:01 | 0.00 | 01-MAY-00:10 |
June | 0.822580E+09 | 0.208351E+09 | 156.12 | 0.703201E+09 | 0.119379E+09 | 0.00 | 1.00 | 13-JUN-07:02 | 0.00 | 01-JUN-00:10 | 15503.57 | 27-JUN-07:02 | 13006.59 | 26-JUN-07:02 | 6841.73 | 27-JUN-07:02 | 3202.85 | 27-JUN-07:02 | 0.00 | 01-JUN-00:10 |
July | 0.125276E+10 | 0.322601E+09 | 200.73 | 0.109747E+10 | 0.155283E+09 | 0.00 | 1.00 | 07-JUL-07:02 | 0.00 | 01-JUL-00:10 | 15504.18 | 18-JUL-07:02 | 13992.78 | 22-JUL-07:02 | 6023.57 | 25-JUL-07:02 | 3291.93 | 22-JUL-07:02 | 0.00 | 01-JUL-00:10 |
August | 0.133166E+10 | 0.341679E+09 | 241.44 | 0.112254E+10 | 0.209124E+09 | 0.00 | 1.00 | 02-AUG-07:02 | 0.00 | 01-AUG-00:10 | 15406.61 | 17-AUG-07:02 | 12938.88 | 15-AUG-07:02 | 6272.84 | 17-AUG-07:02 | 3184.62 | 17-AUG-07:02 | 0.00 | 01-AUG-00:10 |
September | 0.808291E+09 | 0.206190E+09 | 166.57 | 0.697321E+09 | 0.110970E+09 | 0.00 | 1.00 | 01-SEP-07:02 | 0.00 | 01-SEP-00:10 | 15214.84 | 16-SEP-07:02 | 11097.46 | 25-SEP-07:02 | 6035.63 | 16-SEP-07:02 | 3146.65 | 16-SEP-07:02 | 0.00 | 01-SEP-00:10 |
October | 1004491.57 | 272739.32 | 29.86 | 1004403.27 | 88.30 | 0.00 | 0.06 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 | 611.60 | 07-OCT-15:00 | 611.60 | 07-OCT-15:00 | 0.13 | 02-OCT-07:01 | 165.33 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.445058E+10 | 0.113990E+10 | 874.17 | 0.384362E+10 | 0.606959E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.133166E+10 | 0.341679E+09 | 241.44 | 0.112254E+10 | 0.209124E+09 | 0.00 | 1.00 | 0.00 | 15504.18 | 13992.78 | 6841.73 | 3291.93 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.219669E+09 | 58539413.79 | 26.21 | 0.218524E+09 | 1144531.57 | 0.00 | 0.96 | 30-APR-09:02 | 0.00 | 01-APR-00:05 | 25165.17 | 30-APR-09:02 | 24468.75 | 30-APR-09:02 | 696.42 | 30-APR-09:02 | 5411.05 | 30-APR-09:02 | 0.00 | 01-APR-00:05 |
May | 0.123260E+09 | 33469407.87 | 38.71 | 0.110791E+09 | 12469495.76 | 0.00 | 0.38 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 8875.67 | 22-MAY-15:00 | 8179.98 | 22-MAY-15:00 | 1190.67 | 23-MAY-08:62 | 2374.91 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.137885E+10 | 0.361392E+09 | 128.39 | 0.117713E+10 | 0.201719E+09 | 0.00 | 1.00 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 | 28376.11 | 13-JUN-08:62 | 23036.84 | 13-JUN-08:62 | 12436.91 | 27-JUN-08:62 | 6034.35 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.206353E+10 | 0.547539E+09 | 186.07 | 0.181081E+10 | 0.252718E+09 | 0.00 | 1.00 | 07-JUL-08:62 | 0.00 | 01-JUL-00:10 | 28371.00 | 18-JUL-08:62 | 26156.33 | 22-JUL-08:61 | 11017.74 | 25-JUL-08:62 | 6267.20 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.218125E+10 | 0.576596E+09 | 231.01 | 0.184410E+10 | 0.337147E+09 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 28422.97 | 17-AUG-08:62 | 24203.45 | 22-AUG-08:62 | 11356.08 | 17-AUG-08:62 | 6043.07 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.131704E+10 | 0.346976E+09 | 147.67 | 0.113785E+10 | 0.179191E+09 | 0.00 | 1.00 | 02-SEP-08:62 | 0.00 | 01-SEP-00:10 | 28010.18 | 16-SEP-08:62 | 21890.91 | 14-SEP-08:62 | 10024.86 | 16-SEP-08:62 | 5963.20 | 16-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 1451786.79 | 407685.67 | 18.25 | 1443479.23 | 8307.55 | 0.00 | 0.04 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 | 888.14 | 07-OCT-15:00 | 888.14 | 07-OCT-15:00 | 5.02 | 02-OCT-15:10 | 247.92 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.728505E+10 | 0.192492E+10 | 776.29 | 0.630065E+10 | 0.984397E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.218125E+10 | 0.576596E+09 | 231.01 | 0.184410E+10 | 0.337147E+09 | 0.00 | 1.00 | 0.00 | 28422.97 | 26156.33 | 12436.91 | 6267.20 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.107075E+09 | 27795112.49 | 25.54 | 0.106601E+09 | 473598.82 | 0.00 | 0.83 | 30-APR-09:02 | 0.00 | 01-APR-00:05 | 11070.74 | 30-APR-09:02 | 10763.41 | 30-APR-09:02 | 307.33 | 30-APR-09:02 | 2412.94 | 30-APR-09:02 | 0.00 | 01-APR-00:05 |
May | 57856635.07 | 15285250.35 | 38.33 | 52420024.32 | 5436610.74 | 0.00 | 0.37 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 4555.31 | 22-MAY-15:00 | 4202.72 | 22-MAY-15:00 | 354.50 | 22-MAY-14:30 | 1187.93 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.692595E+09 | 0.176938E+09 | 126.68 | 0.593016E+09 | 99578961.52 | 0.00 | 1.00 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 | 15126.44 | 13-JUN-08:62 | 12274.22 | 13-JUN-08:62 | 6627.26 | 27-JUN-08:62 | 3124.01 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.102465E+10 | 0.265062E+09 | 183.72 | 0.904276E+09 | 0.120372E+09 | 0.00 | 1.00 | 07-JUL-08:62 | 0.00 | 01-JUL-00:10 | 15123.60 | 18-JUL-08:62 | 13940.25 | 22-JUL-08:61 | 5868.88 | 25-JUL-08:62 | 3244.55 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.106655E+10 | 0.274399E+09 | 227.41 | 0.906286E+09 | 0.160263E+09 | 0.00 | 1.00 | 01-AUG-08:62 | 0.00 | 01-AUG-00:10 | 15151.34 | 17-AUG-08:62 | 12274.39 | 15-AUG-08:62 | 6051.12 | 17-AUG-08:62 | 3128.51 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.652547E+09 | 0.167432E+09 | 145.58 | 0.565796E+09 | 86751079.64 | 0.00 | 1.00 | 02-SEP-08:62 | 0.00 | 01-SEP-00:10 | 14931.79 | 16-SEP-08:62 | 11676.21 | 14-SEP-08:62 | 5336.89 | 16-SEP-08:62 | 3087.26 | 16-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 310020.99 | 84499.42 | 15.58 | 310007.09 | 13.90 | 0.00 | 0.03 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 | 337.35 | 07-OCT-15:00 | 337.35 | 07-OCT-15:00 | 0.01 | 02-OCT-15:10 | 91.75 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.360158E+10 | 0.926996E+09 | 762.85 | 0.312871E+10 | 0.472875E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.106655E+10 | 0.274399E+09 | 227.41 | 0.906286E+09 | 0.160263E+09 | 0.00 | 1.00 | 0.00 | 15151.34 | 13940.25 | 6627.26 | 3244.55 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.100651E+09 | 26172057.42 | 24.38 | 0.100244E+09 | 406801.94 | 0.00 | 0.73 | 30-APR-09:02 | 0.00 | 01-APR-00:05 | 9450.06 | 30-APR-09:02 | 9176.71 | 30-APR-09:02 | 273.34 | 30-APR-09:02 | 2120.59 | 30-APR-09:02 | 0.00 | 01-APR-00:05 |
May | 52863036.74 | 13984239.33 | 37.03 | 48060653.98 | 4802382.76 | 0.00 | 0.36 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 4405.89 | 22-MAY-15:00 | 4063.44 | 22-MAY-15:00 | 342.44 | 22-MAY-15:00 | 1151.61 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.665125E+09 | 0.170233E+09 | 117.80 | 0.569853E+09 | 95271870.01 | 0.00 | 1.00 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 | 15003.13 | 13-JUN-08:62 | 12154.33 | 13-JUN-08:62 | 6587.68 | 27-JUN-08:62 | 3098.61 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.988565E+09 | 0.256063E+09 | 178.81 | 0.874027E+09 | 0.114538E+09 | 0.00 | 1.00 | 10-JUL-08:62 | 0.00 | 01-JUL-00:10 | 15000.86 | 18-JUL-08:62 | 13816.33 | 22-JUL-08:61 | 5832.79 | 25-JUL-08:62 | 3218.42 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.102589E+10 | 0.264228E+09 | 224.86 | 0.872817E+09 | 0.153070E+09 | 0.00 | 1.00 | 06-AUG-09:02 | 0.00 | 01-AUG-00:10 | 15028.72 | 17-AUG-08:62 | 12164.10 | 15-AUG-08:62 | 6013.92 | 17-AUG-08:62 | 3103.24 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.624792E+09 | 0.160532E+09 | 140.81 | 0.542332E+09 | 82460275.78 | 0.00 | 1.00 | 02-SEP-08:62 | 0.00 | 01-SEP-00:10 | 14811.12 | 16-SEP-08:62 | 11570.44 | 14-SEP-08:62 | 5305.08 | 16-SEP-08:62 | 3062.33 | 16-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 134270.94 | 36647.15 | 10.67 | 134270.94 | 0.00 | 0.00 | 0.02 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 | 205.07 | 07-OCT-15:00 | 205.07 | 07-OCT-15:00 | 0.00 | 03-OCT-15:20 | 55.95 | 07-OCT-15:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.345802E+10 | 0.891248E+09 | 734.34 | 0.300747E+10 | 0.450549E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.102589E+10 | 0.264228E+09 | 224.86 | 0.874027E+09 | 0.153070E+09 | 0.00 | 1.00 | 0.00 | 15028.72 | 13816.33 | 6587.68 | 3218.42 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 88005265.36 | 22980282.95 | 22.79 | 87733507.42 | 271757.94 | 0.00 | 0.44 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 5279.74 | 30-APR-15:00 | 5279.74 | 30-APR-15:00 | 161.12 | 30-APR-09:02 | 1358.46 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 44199690.74 | 11730202.46 | 29.67 | 40424162.29 | 3775528.45 | 0.00 | 0.34 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 4093.37 | 22-MAY-15:00 | 3772.38 | 22-MAY-15:00 | 321.00 | 22-MAY-15:00 | 1075.48 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.605417E+09 | 0.155696E+09 | 93.91 | 0.519510E+09 | 85906434.51 | 0.00 | 1.00 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 | 14784.51 | 13-JUN-08:62 | 11925.04 | 13-JUN-08:62 | 6535.43 | 27-JUN-08:62 | 3053.65 | 13-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.903130E+09 | 0.234744E+09 | 169.37 | 0.803205E+09 | 99925540.83 | 0.00 | 1.00 | 10-JUL-08:62 | 0.00 | 01-JUL-00:10 | 14782.76 | 18-JUL-08:62 | 13584.31 | 22-JUL-08:61 | 5785.31 | 25-JUL-08:62 | 3172.29 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.922550E+09 | 0.238651E+09 | 216.00 | 0.788141E+09 | 0.134409E+09 | 0.00 | 1.00 | 14-AUG-08:62 | 0.00 | 01-AUG-00:10 | 14811.12 | 17-AUG-08:62 | 11954.64 | 15-AUG-08:62 | 5963.68 | 17-AUG-08:62 | 3058.48 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.559285E+09 | 0.144298E+09 | 129.31 | 0.486896E+09 | 72389644.49 | 0.00 | 0.95 | 16-SEP-08:62 | 0.00 | 01-SEP-00:10 | 13602.58 | 16-SEP-08:62 | 8701.91 | 14-SEP-08:62 | 4906.40 | 16-SEP-08:62 | 2861.24 | 16-SEP-08:62 | 0.00 | 01-SEP-00:10 |
October | 11702.87 | 3208.84 | 6.67 | 11702.87 | 0.00 | 0.00 | 0.00 | 05-OCT-15:00 | 0.00 | 01-OCT-00:05 | 7.24 | 05-OCT-15:00 | 7.24 | 05-OCT-15:00 | 0.00 | 07-OCT-15:20 | 1.99 | 05-OCT-15:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.312260E+10 | 0.808103E+09 | 667.72 | 0.272592E+10 | 0.396677E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.922550E+09 | 0.238651E+09 | 216.00 | 0.803205E+09 | 0.134409E+09 | 0.00 | 1.00 | 0.00 | 14811.12 | 13584.31 | 6535.43 | 3172.29 | 0.00 |
Report: DXReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 70290050.26 | 18458295.60 | 19.83 | 70191631.19 | 98419.07 | 0.00 | 0.41 | 30-APR-15:00 | 0.00 | 01-APR-00:05 | 4820.25 | 30-APR-15:00 | 4820.25 | 30-APR-15:00 | 29.72 | 28-APR-15:00 | 1252.58 | 30-APR-15:00 | 0.00 | 01-APR-00:05 |
May | 37214679.63 | 9946314.40 | 16.67 | 34104596.59 | 3110083.04 | 0.00 | 0.31 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 | 3694.71 | 22-MAY-15:00 | 3401.83 | 22-MAY-15:00 | 292.88 | 22-MAY-15:00 | 978.97 | 22-MAY-15:00 | 0.00 | 01-MAY-00:10 |
June | 0.534883E+09 | 0.138675E+09 | 69.89 | 0.460554E+09 | 74329196.36 | 0.00 | 0.95 | 26-JUN-08:62 | 0.00 | 01-JUN-00:10 | 13489.43 | 26-JUN-08:62 | 10815.08 | 26-JUN-08:62 | 2674.35 | 26-JUN-08:62 | 2833.00 | 26-JUN-08:62 | 0.00 | 01-JUN-00:10 |
July | 0.786939E+09 | 0.205377E+09 | 150.97 | 0.711374E+09 | 75565208.26 | 0.00 | 1.00 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 | 14758.62 | 22-JUL-08:61 | 13597.03 | 22-JUL-08:61 | 5616.69 | 24-JUL-08:62 | 3173.81 | 22-JUL-08:61 | 0.00 | 01-JUL-00:10 |
August | 0.749697E+09 | 0.195674E+09 | 193.94 | 0.646325E+09 | 0.103372E+09 | 0.00 | 0.82 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 | 11503.41 | 17-AUG-08:62 | 6814.56 | 17-AUG-08:62 | 4688.85 | 17-AUG-08:62 | 2516.60 | 17-AUG-08:62 | 0.00 | 01-AUG-00:10 |
September | 0.462830E+09 | 0.120293E+09 | 103.20 | 0.404400E+09 | 58429874.14 | 0.00 | 0.44 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 | 5460.48 | 13-SEP-14:10 | 4711.08 | 13-SEP-14:10 | 997.14 | 12-SEP-14:10 | 1373.91 | 13-SEP-14:10 | 0.00 | 01-SEP-00:10 |
October | 4151.66 | 1138.61 | 3.17 | 4151.66 | 0.00 | 0.00 | 0.00 | 07-OCT-13:00 | 0.00 | 01-OCT-00:05 | 0.94 | 07-OCT-13:00 | 0.94 | 07-OCT-13:00 | 0.00 | 07-OCT-15:00 | 0.26 | 07-OCT-13:00 | 0.00 | 01-OCT-00:05 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 | 0.00 | 01-DEC-00:05 |
Annual Sum or Average | 0.264186E+10 | 0.688425E+09 | 557.68 | 0.232695E+10 | 0.314905E+09 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.786939E+09 | 0.205377E+09 | 193.94 | 0.711374E+09 | 0.103372E+09 | 0.00 | 1.00 | 0.00 | 14758.62 | 13597.03 | 5616.69 | 3173.81 | 0.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.40 | 72.10 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.68 | 69.86 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.16 | 58.97 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.60 | 51.26 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.72 | 45.65 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.65 | 36.99 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.98 | 34.39 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.69 | 37.25 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.46 | 47.50 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.60 | 58.98 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.77 | 66.82 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.29 | 81.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.55 | 55.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.16 | 34.39 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.46 | 81.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.40 | 72.10 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.68 | 69.86 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.16 | 58.97 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.60 | 51.26 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.72 | 45.65 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.65 | 36.99 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.98 | 34.39 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.69 | 37.25 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.46 | 47.50 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.60 | 58.98 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.77 | 66.82 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.29 | 81.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.55 | 55.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.16 | 34.39 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.46 | 81.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.40 | 72.10 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.68 | 69.86 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.16 | 58.97 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.60 | 51.26 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.72 | 45.65 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.65 | 36.99 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.98 | 34.39 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.69 | 37.25 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.46 | 47.50 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.60 | 58.98 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.77 | 66.82 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.29 | 81.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.55 | 55.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.16 | 34.39 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.46 | 81.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.40 | 72.10 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.68 | 69.86 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.16 | 58.97 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.60 | 51.26 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.72 | 45.65 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.65 | 36.99 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.98 | 34.39 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.69 | 37.25 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.46 | 47.50 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.60 | 58.98 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.77 | 66.82 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.29 | 81.60 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.55 | 55.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.16 | 34.39 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.46 | 81.60 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 93.41 | 60.46 | 32.95 | 89.62 | 86.22 | 0.00 | 0.00 | 744.00 |
February | 114.12 | 69.64 | 44.48 | 108.02 | 83.49 | 0.00 | 0.00 | 672.00 |
March | 70.57 | 20.56 | 50.01 | 49.65 | 70.52 | 0.00 | 0.00 | 744.00 |
April | 146.52 | 66.23 | 80.29 | 132.01 | 61.33 | 0.00 | 0.00 | 720.00 |
May | 121.16 | 39.43 | 81.72 | 87.68 | 54.54 | 0.00 | 0.00 | 744.00 |
June | 111.61 | 27.00 | 84.61 | 80.34 | 44.22 | 0.00 | 0.00 | 720.00 |
July | 120.93 | 37.86 | 83.07 | 95.14 | 41.14 | 0.00 | 0.00 | 744.00 |
August | 141.72 | 63.75 | 77.97 | 130.84 | 44.59 | 0.00 | 0.00 | 744.00 |
September | 167.54 | 98.17 | 69.37 | 170.27 | 56.84 | 0.00 | 0.00 | 720.00 |
October | 115.09 | 67.28 | 47.81 | 113.90 | 70.54 | 0.00 | 0.00 | 744.00 |
November | 81.56 | 49.61 | 31.95 | 78.01 | 79.89 | 0.00 | 0.00 | 720.00 |
December | 64.64 | 41.40 | 23.23 | 60.59 | 97.49 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.23 | 53.24 | 58.99 | 99.43 | 65.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.64 | 20.56 | 23.23 | 49.65 | 41.14 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 167.54 | 98.17 | 84.61 | 170.27 | 97.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 93.41 | 60.46 | 32.95 | 89.62 | 86.22 | 0.00 | 0.00 | 744.00 |
February | 114.12 | 69.64 | 44.48 | 108.02 | 83.49 | 0.00 | 0.00 | 672.00 |
March | 70.57 | 20.56 | 50.01 | 49.65 | 70.52 | 0.00 | 0.00 | 744.00 |
April | 146.52 | 66.23 | 80.29 | 132.01 | 61.33 | 0.00 | 0.00 | 720.00 |
May | 121.16 | 39.43 | 81.72 | 87.68 | 54.54 | 0.00 | 0.00 | 744.00 |
June | 111.61 | 27.00 | 84.61 | 80.34 | 44.22 | 0.00 | 0.00 | 720.00 |
July | 120.93 | 37.86 | 83.07 | 95.14 | 41.14 | 0.00 | 0.00 | 744.00 |
August | 141.72 | 63.75 | 77.97 | 130.84 | 44.59 | 0.00 | 0.00 | 744.00 |
September | 167.54 | 98.17 | 69.37 | 170.27 | 56.84 | 0.00 | 0.00 | 720.00 |
October | 115.09 | 67.28 | 47.81 | 113.90 | 70.54 | 0.00 | 0.00 | 744.00 |
November | 81.56 | 49.61 | 31.95 | 78.01 | 79.89 | 0.00 | 0.00 | 720.00 |
December | 64.64 | 41.40 | 23.23 | 60.59 | 97.49 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.23 | 53.24 | 58.99 | 99.43 | 65.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.64 | 20.56 | 23.23 | 49.65 | 41.14 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 167.54 | 98.17 | 84.61 | 170.27 | 97.49 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 73.61 | 75.91 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 88.81 | 73.73 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.25 | 62.73 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 107.99 | 54.47 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.11 | 48.53 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 65.87 | 38.05 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.50 | 35.13 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.28 | 37.93 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.93 | 48.45 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.58 | 62.47 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.02 | 70.97 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 49.76 | 85.76 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 81.70 | 57.77 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.25 | 35.13 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.93 | 85.76 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 73.61 | 75.91 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 88.81 | 73.73 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.25 | 62.73 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 107.99 | 54.47 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.11 | 48.53 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 65.87 | 38.05 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.50 | 35.13 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.28 | 37.93 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 140.93 | 48.45 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 93.58 | 62.47 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.02 | 70.97 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 49.76 | 85.76 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 81.70 | 57.77 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.25 | 35.13 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 140.93 | 85.76 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 93.41 | 60.46 | 32.95 | 88.66 | 90.75 | 0.00 | 0.00 | 744.00 |
February | 114.12 | 69.64 | 44.48 | 106.98 | 88.07 | 0.00 | 0.00 | 672.00 |
March | 70.57 | 20.56 | 50.01 | 48.55 | 74.98 | 0.00 | 0.00 | 744.00 |
April | 146.52 | 66.23 | 80.29 | 130.08 | 65.13 | 0.00 | 0.00 | 720.00 |
May | 121.16 | 39.43 | 81.72 | 85.75 | 57.95 | 0.00 | 0.00 | 744.00 |
June | 111.61 | 27.00 | 84.61 | 79.41 | 45.47 | 0.00 | 0.00 | 720.00 |
July | 120.93 | 37.86 | 83.07 | 94.57 | 42.01 | 0.00 | 0.00 | 744.00 |
August | 141.72 | 63.75 | 77.97 | 130.36 | 45.40 | 0.00 | 0.00 | 744.00 |
September | 167.54 | 98.17 | 69.37 | 169.64 | 57.97 | 0.00 | 0.00 | 720.00 |
October | 115.09 | 67.28 | 47.81 | 112.67 | 74.68 | 0.00 | 0.00 | 744.00 |
November | 81.56 | 49.61 | 31.95 | 77.11 | 84.81 | 0.00 | 0.00 | 720.00 |
December | 64.64 | 41.40 | 23.23 | 59.96 | 102.42 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 112.23 | 53.24 | 58.99 | 98.41 | 69.04 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.64 | 20.56 | 23.23 | 48.55 | 42.01 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 167.54 | 98.17 | 84.61 | 169.64 | 102.42 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 73.95 | 73.53 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.14 | 71.48 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.59 | 60.57 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.64 | 53.30 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.70 | 47.69 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.00 | 38.58 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.47 | 36.00 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.30 | 38.95 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.04 | 49.10 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.06 | 60.75 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.39 | 68.36 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 49.99 | 83.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 81.99 | 56.72 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.59 | 36.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.04 | 83.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 73.95 | 73.53 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.14 | 71.48 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.59 | 60.57 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 108.64 | 53.30 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 71.70 | 47.69 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.00 | 38.58 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.47 | 36.00 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.30 | 38.95 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.04 | 49.10 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.06 | 60.75 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.39 | 68.36 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 49.99 | 83.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 81.99 | 56.72 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.59 | 36.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.04 | 83.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 88.60 | 87.42 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 106.79 | 84.92 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 48.70 | 72.01 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 130.14 | 63.37 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 85.99 | 56.63 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 79.12 | 45.83 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.01 | 42.78 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 129.66 | 46.32 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 168.84 | 58.39 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 112.63 | 72.23 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.13 | 81.24 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 59.90 | 98.88 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 98.22 | 67.42 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 48.70 | 42.78 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 168.84 | 98.88 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.13 | 72.51 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.30 | 70.56 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.77 | 59.67 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.08 | 52.31 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.16 | 46.79 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.14 | 38.27 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.55 | 35.80 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.34 | 38.79 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.12 | 48.81 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.34 | 59.63 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.56 | 67.27 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.10 | 82.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.18 | 55.98 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.77 | 35.80 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.12 | 82.20 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.13 | 72.51 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.30 | 70.56 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.77 | 59.67 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.08 | 52.31 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.16 | 46.79 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.14 | 38.27 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.55 | 35.80 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.34 | 38.79 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.12 | 48.81 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.34 | 59.63 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.56 | 67.27 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.10 | 82.20 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.18 | 55.98 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.77 | 35.80 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.12 | 82.20 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 88.80 | 86.21 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 106.99 | 83.83 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 48.91 | 70.94 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 130.67 | 62.20 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 86.53 | 55.56 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 79.30 | 45.47 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.11 | 42.55 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 129.71 | 46.14 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 168.94 | 58.05 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 112.97 | 70.90 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.34 | 79.95 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.03 | 97.63 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 98.46 | 66.53 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 48.91 | 42.55 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 168.94 | 97.63 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.27 | 71.84 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.45 | 69.95 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.93 | 59.08 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.55 | 51.46 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.69 | 45.92 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.39 | 37.86 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.71 | 35.49 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.45 | 38.51 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.25 | 48.46 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.61 | 58.73 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.69 | 66.60 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.21 | 81.44 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.40 | 55.37 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.93 | 35.49 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.25 | 81.44 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.27 | 71.84 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.45 | 69.95 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 40.93 | 59.08 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 109.55 | 51.46 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 72.69 | 45.92 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.39 | 37.86 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.71 | 35.49 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.45 | 38.51 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.25 | 48.46 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 94.61 | 58.73 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.69 | 66.60 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.21 | 81.44 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.40 | 55.37 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 40.93 | 35.49 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.25 | 81.44 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 88.98 | 85.40 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 107.17 | 83.10 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 49.11 | 70.23 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 131.23 | 61.19 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 87.16 | 54.53 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 79.60 | 44.98 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.30 | 42.18 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 129.84 | 45.80 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.10 | 57.64 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 113.30 | 69.82 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.50 | 79.15 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.17 | 96.73 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 98.72 | 65.81 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 49.11 | 42.18 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.10 | 96.73 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.76 | 70.29 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.97 | 68.47 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.42 | 57.77 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.32 | 49.98 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.48 | 44.40 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.87 | 36.84 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.92 | 34.67 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.57 | 37.71 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.49 | 47.60 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.15 | 57.11 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.06 | 65.15 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.59 | 79.41 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.85 | 54.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.42 | 34.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.49 | 79.41 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.76 | 70.29 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.97 | 68.47 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.42 | 57.77 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.32 | 49.98 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.48 | 44.40 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.87 | 36.84 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.92 | 34.67 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.57 | 37.71 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.49 | 47.60 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.15 | 57.11 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.06 | 65.15 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.59 | 79.41 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.85 | 54.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.42 | 34.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.49 | 79.41 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.76 | 70.29 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.97 | 68.47 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.42 | 57.77 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.32 | 49.98 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.48 | 44.40 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.87 | 36.84 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.92 | 34.67 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.57 | 37.71 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.49 | 47.60 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.15 | 57.11 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.06 | 65.15 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.59 | 79.41 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.85 | 54.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.42 | 34.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.49 | 79.41 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.76 | 70.29 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.97 | 68.47 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.42 | 57.77 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.32 | 49.98 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.48 | 44.40 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.87 | 36.84 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.92 | 34.67 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.57 | 37.71 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.49 | 47.60 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.15 | 57.11 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.06 | 65.15 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.59 | 79.41 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.85 | 54.05 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.42 | 34.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.49 | 79.41 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 89.57 | 83.56 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 107.80 | 81.35 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 49.71 | 68.68 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 132.16 | 59.43 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 88.12 | 52.73 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 80.18 | 43.78 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.56 | 41.21 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 129.99 | 44.86 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.38 | 56.62 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 113.93 | 67.91 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.94 | 77.43 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.63 | 94.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 99.26 | 64.24 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 49.71 | 41.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.38 | 94.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 89.57 | 83.56 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 107.80 | 81.35 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 49.71 | 68.68 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 132.16 | 59.43 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 88.12 | 52.73 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 80.18 | 43.78 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.56 | 41.21 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 129.99 | 44.86 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.38 | 56.62 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 113.93 | 67.91 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.94 | 77.43 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.63 | 94.31 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 99.26 | 64.24 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 49.71 | 41.21 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.38 | 94.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.63 | 70.37 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.83 | 68.58 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.30 | 57.78 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.35 | 49.75 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.55 | 44.21 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.94 | 36.68 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.98 | 34.52 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.58 | 37.55 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.42 | 47.50 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.08 | 56.99 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.96 | 65.25 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.50 | 79.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.81 | 54.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.30 | 34.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.42 | 79.70 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.63 | 70.37 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.83 | 68.58 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.30 | 57.78 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.35 | 49.75 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.55 | 44.21 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 66.94 | 36.68 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 78.98 | 34.52 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.58 | 37.55 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.42 | 47.50 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.08 | 56.99 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 64.96 | 65.25 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.50 | 79.70 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.81 | 54.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.30 | 34.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.42 | 79.70 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 89.42 | 83.65 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 107.63 | 81.46 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 49.57 | 68.68 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 132.20 | 59.15 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 88.21 | 52.50 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 80.28 | 43.58 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.64 | 41.03 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 130.02 | 44.67 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.32 | 56.49 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 113.86 | 67.75 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.82 | 77.53 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.52 | 94.63 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 99.22 | 64.17 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 49.57 | 41.03 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.32 | 94.63 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.71 | 70.07 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.92 | 68.28 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.39 | 57.50 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.59 | 49.35 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.83 | 43.79 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 67.22 | 36.34 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 79.15 | 34.29 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.67 | 37.39 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.54 | 47.26 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.25 | 56.54 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.02 | 64.96 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.55 | 79.37 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.96 | 53.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.39 | 34.29 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.54 | 79.37 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.71 | 70.07 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 89.92 | 68.28 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.39 | 57.50 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 110.59 | 49.35 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 73.83 | 43.79 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 67.22 | 36.34 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 79.15 | 34.29 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.67 | 37.39 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.54 | 47.26 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.25 | 56.54 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.02 | 64.96 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.55 | 79.37 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 82.96 | 53.69 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.39 | 34.29 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.54 | 79.37 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 89.52 | 83.29 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 107.74 | 81.10 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 49.68 | 68.34 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 132.49 | 58.68 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 88.54 | 52.00 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 80.61 | 43.17 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 94.84 | 40.76 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 130.13 | 44.48 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.46 | 56.20 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 114.06 | 67.22 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 77.90 | 77.19 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.58 | 94.25 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 99.39 | 63.80 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 49.68 | 40.76 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.46 | 94.25 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.94 | 69.05 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 90.19 | 67.23 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.65 | 56.54 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 111.10 | 48.37 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 74.46 | 42.75 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 67.90 | 35.44 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 79.56 | 33.67 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.91 | 36.91 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.88 | 46.54 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.65 | 55.42 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.20 | 64.04 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.71 | 78.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 83.32 | 52.78 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.65 | 33.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.88 | 78.27 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 74.94 | 69.05 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 90.19 | 67.23 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 41.65 | 56.54 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 111.10 | 48.37 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 74.46 | 42.75 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 67.90 | 35.44 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 79.56 | 33.67 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 108.91 | 36.91 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 141.88 | 46.54 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 95.65 | 55.42 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.20 | 64.04 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 50.71 | 78.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 83.32 | 52.78 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 41.65 | 33.67 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 141.88 | 78.27 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 89.79 | 82.07 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 108.07 | 79.85 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 49.99 | 67.20 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 133.11 | 57.52 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 89.30 | 50.76 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 81.42 | 42.11 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 95.34 | 40.02 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 130.41 | 43.91 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 169.87 | 55.35 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 114.54 | 65.88 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 78.12 | 76.10 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 60.78 | 92.93 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 99.83 | 62.72 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 49.99 | 40.02 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 169.87 | 92.93 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 75.67 | 65.51 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 91.10 | 63.44 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 42.55 | 53.14 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 112.20 | 45.50 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 75.88 | 39.61 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 69.52 | 32.74 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 80.63 | 31.56 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 109.61 | 35.00 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 142.77 | 44.08 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 96.55 | 52.25 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.81 | 60.79 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 51.23 | 74.35 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 84.26 | 49.76 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 42.55 | 31.56 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 142.77 | 74.35 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 77.59 | 50.22 | 27.37 | 75.67 | 65.51 | 0.00 | 0.00 | 744.00 |
February | 94.79 | 57.84 | 36.94 | 91.10 | 63.44 | 0.00 | 0.00 | 672.00 |
March | 58.61 | 17.07 | 41.54 | 42.55 | 53.14 | 0.00 | 0.00 | 744.00 |
April | 121.70 | 55.01 | 66.69 | 112.20 | 45.50 | 0.00 | 0.00 | 720.00 |
May | 100.63 | 32.75 | 67.88 | 75.88 | 39.61 | 0.00 | 0.00 | 744.00 |
June | 92.70 | 22.43 | 70.27 | 69.52 | 32.74 | 0.00 | 0.00 | 720.00 |
July | 100.44 | 31.44 | 69.00 | 80.63 | 31.56 | 0.00 | 0.00 | 744.00 |
August | 117.71 | 52.95 | 64.76 | 109.61 | 35.00 | 0.00 | 0.00 | 744.00 |
September | 139.16 | 81.54 | 57.62 | 142.77 | 44.08 | 0.00 | 0.00 | 720.00 |
October | 95.60 | 55.88 | 39.72 | 96.55 | 52.25 | 0.00 | 0.00 | 744.00 |
November | 67.75 | 41.20 | 26.54 | 65.81 | 60.79 | 0.00 | 0.00 | 720.00 |
December | 53.69 | 34.39 | 19.30 | 51.23 | 74.35 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 93.22 | 44.22 | 49.00 | 84.26 | 49.76 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 53.69 | 17.07 | 19.30 | 42.55 | 31.56 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 139.16 | 81.54 | 70.27 | 142.77 | 74.35 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 92.90 | 60.13 | 32.77 | 90.68 | 77.85 | 0.00 | 0.00 | 744.00 |
February | 113.49 | 69.26 | 44.24 | 109.17 | 75.34 | 0.00 | 0.00 | 672.00 |
March | 70.18 | 20.44 | 49.74 | 51.09 | 63.15 | 0.00 | 0.00 | 744.00 |
April | 145.72 | 65.87 | 79.85 | 134.43 | 54.10 | 0.00 | 0.00 | 720.00 |
May | 120.49 | 39.22 | 81.28 | 91.01 | 47.04 | 0.00 | 0.00 | 744.00 |
June | 111.00 | 26.86 | 84.15 | 83.35 | 38.91 | 0.00 | 0.00 | 720.00 |
July | 120.27 | 37.65 | 82.62 | 96.62 | 37.52 | 0.00 | 0.00 | 744.00 |
August | 140.94 | 63.40 | 77.54 | 131.25 | 41.64 | 0.00 | 0.00 | 744.00 |
September | 166.62 | 97.64 | 68.99 | 170.93 | 52.44 | 0.00 | 0.00 | 720.00 |
October | 114.46 | 66.91 | 47.55 | 115.62 | 62.12 | 0.00 | 0.00 | 744.00 |
November | 81.12 | 49.34 | 31.78 | 78.86 | 72.22 | 0.00 | 0.00 | 720.00 |
December | 64.28 | 41.18 | 23.11 | 61.41 | 88.27 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 111.62 | 52.95 | 58.67 | 100.97 | 59.14 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 64.28 | 20.44 | 23.11 | 51.09 | 37.52 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 166.62 | 97.64 | 84.15 | 170.93 | 88.27 | 0.00 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.199274E+09 | 0.193110E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216950E+09 | 0.169016E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110237E+09 | 0.157956E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.284079E+09 | 0.132875E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.194781E+09 | 0.122271E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.172751E+09 | 95877647.77 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211547E+09 | 92113206.31 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291113E+09 | 99763033.71 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366657E+09 | 0.123115E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.253380E+09 | 0.157966E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167885E+09 | 0.173198E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134697E+09 | 0.218567E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.260335E+10 | 0.173583E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110237E+09 | 92113206.31 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366657E+09 | 0.218567E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.199274E+09 | 0.193110E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216950E+09 | 0.169016E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110237E+09 | 0.157956E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.284079E+09 | 0.132875E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.194781E+09 | 0.122271E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.172751E+09 | 95877647.77 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211547E+09 | 92113206.31 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291113E+09 | 99763033.71 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366657E+09 | 0.123115E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.253380E+09 | 0.157966E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167885E+09 | 0.173198E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134697E+09 | 0.218567E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.260335E+10 | 0.173583E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110237E+09 | 92113206.31 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366657E+09 | 0.218567E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.199274E+09 | 0.193110E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216950E+09 | 0.169016E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110237E+09 | 0.157956E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.284079E+09 | 0.132875E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.194781E+09 | 0.122271E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.172751E+09 | 95877647.77 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211547E+09 | 92113206.31 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291113E+09 | 99763033.71 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366657E+09 | 0.123115E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.253380E+09 | 0.157966E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167885E+09 | 0.173198E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134697E+09 | 0.218567E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.260335E+10 | 0.173583E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110237E+09 | 92113206.31 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366657E+09 | 0.218567E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.199274E+09 | 0.193110E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216950E+09 | 0.169016E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110237E+09 | 0.157956E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.284079E+09 | 0.132875E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.194781E+09 | 0.122271E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.172751E+09 | 95877647.77 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211547E+09 | 92113206.31 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291113E+09 | 99763033.71 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366657E+09 | 0.123115E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.253380E+09 | 0.157966E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167885E+09 | 0.173198E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134697E+09 | 0.218567E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.260335E+10 | 0.173583E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110237E+09 | 92113206.31 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366657E+09 | 0.218567E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.250185E+09 | 0.161931E+09 | 88254240.26 | 0.240025E+09 | 0.230925E+09 |
February | 0.276074E+09 | 0.168469E+09 | 0.107605E+09 | 0.261333E+09 | 0.201979E+09 |
March | 0.189005E+09 | 55057383.18 | 0.133948E+09 | 0.132985E+09 | 0.188888E+09 |
April | 0.379783E+09 | 0.171678E+09 | 0.208105E+09 | 0.342163E+09 | 0.158958E+09 |
May | 0.324506E+09 | 0.105616E+09 | 0.218890E+09 | 0.234845E+09 | 0.146093E+09 |
June | 0.289298E+09 | 69995254.52 | 0.219302E+09 | 0.208237E+09 | 0.114631E+09 |
July | 0.323894E+09 | 0.101397E+09 | 0.222497E+09 | 0.254822E+09 | 0.110180E+09 |
August | 0.379581E+09 | 0.170744E+09 | 0.208837E+09 | 0.350451E+09 | 0.119428E+09 |
September | 0.434262E+09 | 0.254462E+09 | 0.179800E+09 | 0.441330E+09 | 0.147334E+09 |
October | 0.308261E+09 | 0.180194E+09 | 0.128067E+09 | 0.305057E+09 | 0.188937E+09 |
November | 0.211408E+09 | 0.128585E+09 | 82822935.91 | 0.202198E+09 | 0.207073E+09 |
December | 0.173124E+09 | 0.110898E+09 | 62225275.44 | 0.162279E+09 | 0.261115E+09 |
Annual Sum or Average | 0.353938E+10 | 0.167903E+10 | 0.186035E+10 | 0.313573E+10 | 0.207554E+10 |
Minimum of Months | 0.173124E+09 | 55057383.18 | 62225275.44 | 0.132985E+09 | 0.110180E+09 |
Maximum of Months | 0.434262E+09 | 0.254462E+09 | 0.222497E+09 | 0.441330E+09 | 0.261115E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE1_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.250185E+09 | 0.161931E+09 | 88254240.26 | 0.240025E+09 | 0.230925E+09 |
February | 0.276074E+09 | 0.168469E+09 | 0.107605E+09 | 0.261333E+09 | 0.201979E+09 |
March | 0.189005E+09 | 55057383.18 | 0.133948E+09 | 0.132985E+09 | 0.188888E+09 |
April | 0.379783E+09 | 0.171678E+09 | 0.208105E+09 | 0.342163E+09 | 0.158958E+09 |
May | 0.324506E+09 | 0.105616E+09 | 0.218890E+09 | 0.234845E+09 | 0.146093E+09 |
June | 0.289298E+09 | 69995254.52 | 0.219302E+09 | 0.208237E+09 | 0.114631E+09 |
July | 0.323894E+09 | 0.101397E+09 | 0.222497E+09 | 0.254822E+09 | 0.110180E+09 |
August | 0.379581E+09 | 0.170744E+09 | 0.208837E+09 | 0.350451E+09 | 0.119428E+09 |
September | 0.434262E+09 | 0.254462E+09 | 0.179800E+09 | 0.441330E+09 | 0.147334E+09 |
October | 0.308261E+09 | 0.180194E+09 | 0.128067E+09 | 0.305057E+09 | 0.188937E+09 |
November | 0.211408E+09 | 0.128585E+09 | 82822935.91 | 0.202198E+09 | 0.207073E+09 |
December | 0.173124E+09 | 0.110898E+09 | 62225275.44 | 0.162279E+09 | 0.261115E+09 |
Annual Sum or Average | 0.353938E+10 | 0.167903E+10 | 0.186035E+10 | 0.313573E+10 | 0.207554E+10 |
Minimum of Months | 0.173124E+09 | 55057383.18 | 62225275.44 | 0.132985E+09 | 0.110180E+09 |
Maximum of Months | 0.434262E+09 | 0.254462E+09 | 0.222497E+09 | 0.441330E+09 | 0.261115E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.197156E+09 | 0.203330E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.214847E+09 | 0.178371E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.107796E+09 | 0.168005E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.279905E+09 | 0.141174E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.190451E+09 | 0.129985E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.170747E+09 | 98619834.29 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210267E+09 | 94091201.04 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290022E+09 | 0.101588E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.365294E+09 | 0.125587E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250634E+09 | 0.167323E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.165940E+09 | 0.183955E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.133289E+09 | 0.229707E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.257635E+10 | 0.182174E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.107796E+09 | 94091201.04 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.365294E+09 | 0.229707E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.197156E+09 | 0.203330E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.214847E+09 | 0.178371E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.107796E+09 | 0.168005E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.279905E+09 | 0.141174E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.190451E+09 | 0.129985E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.170747E+09 | 98619834.29 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210267E+09 | 94091201.04 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290022E+09 | 0.101588E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.365294E+09 | 0.125587E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.250634E+09 | 0.167323E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.165940E+09 | 0.183955E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.133289E+09 | 0.229707E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.257635E+10 | 0.182174E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.107796E+09 | 94091201.04 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.365294E+09 | 0.229707E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE1_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.250185E+09 | 0.161931E+09 | 88254240.26 | 0.237477E+09 | 0.243067E+09 |
February | 0.276074E+09 | 0.168469E+09 | 0.107605E+09 | 0.258802E+09 | 0.213065E+09 |
March | 0.189005E+09 | 55057383.18 | 0.133948E+09 | 0.130037E+09 | 0.200817E+09 |
April | 0.379783E+09 | 0.171678E+09 | 0.208105E+09 | 0.337173E+09 | 0.168810E+09 |
May | 0.324506E+09 | 0.105616E+09 | 0.218890E+09 | 0.229668E+09 | 0.155219E+09 |
June | 0.289298E+09 | 69995254.52 | 0.219302E+09 | 0.205838E+09 | 0.117871E+09 |
July | 0.323894E+09 | 0.101397E+09 | 0.222497E+09 | 0.253289E+09 | 0.112512E+09 |
August | 0.379581E+09 | 0.170744E+09 | 0.208837E+09 | 0.349144E+09 | 0.121589E+09 |
September | 0.434262E+09 | 0.254462E+09 | 0.179800E+09 | 0.439704E+09 | 0.150260E+09 |
October | 0.308261E+09 | 0.180194E+09 | 0.128067E+09 | 0.301781E+09 | 0.200033E+09 |
November | 0.211408E+09 | 0.128585E+09 | 82822935.91 | 0.199869E+09 | 0.219819E+09 |
December | 0.173124E+09 | 0.110898E+09 | 62225275.44 | 0.160588E+09 | 0.274334E+09 |
Annual Sum or Average | 0.353938E+10 | 0.167903E+10 | 0.186035E+10 | 0.310337E+10 | 0.217740E+10 |
Minimum of Months | 0.173124E+09 | 55057383.18 | 62225275.44 | 0.130037E+09 | 0.112512E+09 |
Maximum of Months | 0.434262E+09 | 0.254462E+09 | 0.222497E+09 | 0.439704E+09 | 0.274334E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.198078E+09 | 0.196934E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.215640E+09 | 0.172928E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.108705E+09 | 0.162232E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.281586E+09 | 0.138153E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.192040E+09 | 0.127741E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.171061E+09 | 0.100004E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210171E+09 | 96424263.54 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290058E+09 | 0.104312E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.365579E+09 | 0.127257E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.251929E+09 | 0.162721E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.166902E+09 | 0.177181E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.133886E+09 | 0.222970E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.258563E+10 | 0.178886E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.108705E+09 | 96424263.54 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.365579E+09 | 0.222970E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.198078E+09 | 0.196934E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.215640E+09 | 0.172928E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.108705E+09 | 0.162232E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.281586E+09 | 0.138153E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.192040E+09 | 0.127741E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.171061E+09 | 0.100004E+09 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210171E+09 | 96424263.54 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290058E+09 | 0.104312E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.365579E+09 | 0.127257E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.251929E+09 | 0.162721E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.166902E+09 | 0.177181E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.133886E+09 | 0.222970E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.258563E+10 | 0.178886E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.108705E+09 | 96424263.54 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.365579E+09 | 0.222970E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE2_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.237294E+09 | 0.234143E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.258348E+09 | 0.205448E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.130427E+09 | 0.192872E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.337334E+09 | 0.164266E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.230303E+09 | 0.151675E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.205088E+09 | 0.118799E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.251797E+09 | 0.114583E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.347276E+09 | 0.124073E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.437641E+09 | 0.151344E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.301674E+09 | 0.193453E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.199930E+09 | 0.210585E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.160434E+09 | 0.264843E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.309755E+10 | 0.212608E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.130427E+09 | 0.114583E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.437641E+09 | 0.264843E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.198537E+09 | 0.194209E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216037E+09 | 0.170698E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.109186E+09 | 0.159817E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.282733E+09 | 0.135591E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.193270E+09 | 0.125326E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.171433E+09 | 99202278.85 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210382E+09 | 95893524.19 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290180E+09 | 0.103901E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.365783E+09 | 0.126522E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.252672E+09 | 0.159725E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167336E+09 | 0.174371E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134184E+09 | 0.220162E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.259173E+10 | 0.176542E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.109186E+09 | 95893524.19 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.365783E+09 | 0.220162E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.198537E+09 | 0.194209E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216037E+09 | 0.170698E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.109186E+09 | 0.159817E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.282733E+09 | 0.135591E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.193270E+09 | 0.125326E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.171433E+09 | 99202278.85 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210382E+09 | 95893524.19 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290180E+09 | 0.103901E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.365783E+09 | 0.126522E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.252672E+09 | 0.159725E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167336E+09 | 0.174371E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134184E+09 | 0.220162E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.259173E+10 | 0.176542E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.109186E+09 | 95893524.19 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.365783E+09 | 0.220162E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE3_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.237851E+09 | 0.230892E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.258832E+09 | 0.202790E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.131012E+09 | 0.189994E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.338708E+09 | 0.161219E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.231774E+09 | 0.148810E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.205537E+09 | 0.117847E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.252053E+09 | 0.113953E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.347423E+09 | 0.123584E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.437889E+09 | 0.150471E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.302566E+09 | 0.189891E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.200454E+09 | 0.207237E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.160796E+09 | 0.261493E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.310489E+10 | 0.209818E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.131012E+09 | 0.113953E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.437889E+09 | 0.261493E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.198929E+09 | 0.192408E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216398E+09 | 0.169232E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.109618E+09 | 0.158228E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.283944E+09 | 0.133392E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.194680E+09 | 0.123001E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.172089E+09 | 98134771.25 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210804E+09 | 95063542.39 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290470E+09 | 0.103136E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366128E+09 | 0.125614E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.253416E+09 | 0.157291E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167684E+09 | 0.172616E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134474E+09 | 0.218142E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.259863E+10 | 0.174626E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.109618E+09 | 95063542.39 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366128E+09 | 0.218142E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.198929E+09 | 0.192408E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.216398E+09 | 0.169232E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.109618E+09 | 0.158228E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.283944E+09 | 0.133392E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.194680E+09 | 0.123001E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.172089E+09 | 98134771.25 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.210804E+09 | 95063542.39 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290470E+09 | 0.103136E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366128E+09 | 0.125614E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.253416E+09 | 0.157291E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.167684E+09 | 0.172616E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.134474E+09 | 0.218142E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.259863E+10 | 0.174626E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.109618E+09 | 95063542.39 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366128E+09 | 0.218142E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE4_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.238327E+09 | 0.228745E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.259270E+09 | 0.201046E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.131536E+09 | 0.188100E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.340156E+09 | 0.158607E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.233460E+09 | 0.146056E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.206326E+09 | 0.116584E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.252561E+09 | 0.112973E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.347775E+09 | 0.122681E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.438305E+09 | 0.149397E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.303456E+09 | 0.186998E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.200876E+09 | 0.205147E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.161148E+09 | 0.259084E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.311319E+10 | 0.207542E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.131536E+09 | 0.112973E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.438305E+09 | 0.259084E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200245E+09 | 0.188265E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217661E+09 | 0.165648E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110942E+09 | 0.154738E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.285952E+09 | 0.129546E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.196814E+09 | 0.118911E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.173333E+09 | 95501558.15 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211374E+09 | 92856035.60 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290785E+09 | 0.100996E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366738E+09 | 0.123390E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254844E+09 | 0.152975E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168648E+09 | 0.168872E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135512E+09 | 0.212692E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261285E+10 | 0.170439E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110942E+09 | 92856035.60 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366738E+09 | 0.212692E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200245E+09 | 0.188265E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217661E+09 | 0.165648E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110942E+09 | 0.154738E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.285952E+09 | 0.129546E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.196814E+09 | 0.118911E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.173333E+09 | 95501558.15 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211374E+09 | 92856035.60 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290785E+09 | 0.100996E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366738E+09 | 0.123390E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254844E+09 | 0.152975E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168648E+09 | 0.168872E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135512E+09 | 0.212692E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261285E+10 | 0.170439E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110942E+09 | 92856035.60 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366738E+09 | 0.212692E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200245E+09 | 0.188265E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217661E+09 | 0.165648E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110942E+09 | 0.154738E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.285952E+09 | 0.129546E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.196814E+09 | 0.118911E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.173333E+09 | 95501558.15 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211374E+09 | 92856035.60 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290785E+09 | 0.100996E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366738E+09 | 0.123390E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254844E+09 | 0.152975E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168648E+09 | 0.168872E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135512E+09 | 0.212692E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261285E+10 | 0.170439E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110942E+09 | 92856035.60 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366738E+09 | 0.212692E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_WINDOW_4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200245E+09 | 0.188265E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217661E+09 | 0.165648E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110942E+09 | 0.154738E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.285952E+09 | 0.129546E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.196814E+09 | 0.118911E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.173333E+09 | 95501558.15 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211374E+09 | 92856035.60 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290785E+09 | 0.100996E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366738E+09 | 0.123390E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254844E+09 | 0.152975E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168648E+09 | 0.168872E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135512E+09 | 0.212692E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261285E+10 | 0.170439E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110942E+09 | 92856035.60 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366738E+09 | 0.212692E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.239902E+09 | 0.223814E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.260778E+09 | 0.196795E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.133135E+09 | 0.183952E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.342557E+09 | 0.154051E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.236013E+09 | 0.141231E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.207825E+09 | 0.113485E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.253259E+09 | 0.110376E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.348174E+09 | 0.120159E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.439045E+09 | 0.146772E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.305159E+09 | 0.181884E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.202027E+09 | 0.200699E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.162385E+09 | 0.252612E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.313026E+10 | 0.202583E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.133135E+09 | 0.110376E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.439045E+09 | 0.252612E+09 |
Report: WindowEnergyReportMonthly
For: LGSTORE2_WALL_1_DOOR_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.239902E+09 | 0.223814E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.260778E+09 | 0.196795E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.133135E+09 | 0.183952E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.342557E+09 | 0.154051E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.236013E+09 | 0.141231E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.207825E+09 | 0.113485E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.253259E+09 | 0.110376E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.348174E+09 | 0.120159E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.439045E+09 | 0.146772E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.305159E+09 | 0.181884E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.202027E+09 | 0.200699E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.162385E+09 | 0.252612E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.313026E+10 | 0.202583E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.133135E+09 | 0.110376E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.439045E+09 | 0.252612E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.199899E+09 | 0.188487E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217307E+09 | 0.165913E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110625E+09 | 0.154755E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.286023E+09 | 0.128957E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.197000E+09 | 0.118413E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.173520E+09 | 95083377.07 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211552E+09 | 92457221.38 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290814E+09 | 0.100577E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366565E+09 | 0.123116E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254659E+09 | 0.152641E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168372E+09 | 0.169116E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135252E+09 | 0.213455E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261159E+10 | 0.170297E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110625E+09 | 92457221.38 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366565E+09 | 0.213455E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.199899E+09 | 0.188487E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217307E+09 | 0.165913E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110625E+09 | 0.154755E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.286023E+09 | 0.128957E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.197000E+09 | 0.118413E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.173520E+09 | 95083377.07 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211552E+09 | 92457221.38 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.290814E+09 | 0.100577E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366565E+09 | 0.123116E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.254659E+09 | 0.152641E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168372E+09 | 0.169116E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135252E+09 | 0.213455E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261159E+10 | 0.170297E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110625E+09 | 92457221.38 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366565E+09 | 0.213455E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE5_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.239512E+09 | 0.224048E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.260382E+09 | 0.197075E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.132775E+09 | 0.183949E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.342672E+09 | 0.153330E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.236263E+09 | 0.140609E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.208074E+09 | 0.112965E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.253494E+09 | 0.109882E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.348233E+09 | 0.119646E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.438869E+09 | 0.146425E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.304965E+09 | 0.181454E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.201716E+09 | 0.200954E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.162092E+09 | 0.253469E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.312905E+10 | 0.202381E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.132775E+09 | 0.109882E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.438869E+09 | 0.253469E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200105E+09 | 0.187672E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217523E+09 | 0.165179E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110860E+09 | 0.154005E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.286649E+09 | 0.127919E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.197745E+09 | 0.117284E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.174238E+09 | 94191647.23 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211993E+09 | 91850810.42 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291068E+09 | 0.100136E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366883E+09 | 0.122487E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.255108E+09 | 0.151446E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168532E+09 | 0.168386E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135393E+09 | 0.212595E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261610E+10 | 0.169315E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110860E+09 | 91850810.42 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366883E+09 | 0.212595E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200105E+09 | 0.187672E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.217523E+09 | 0.165179E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.110860E+09 | 0.154005E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.286649E+09 | 0.127919E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.197745E+09 | 0.117284E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.174238E+09 | 94191647.23 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.211993E+09 | 91850810.42 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291068E+09 | 0.100136E+09 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.366883E+09 | 0.122487E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.255108E+09 | 0.151446E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.168532E+09 | 0.168386E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135393E+09 | 0.212595E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.261610E+10 | 0.169315E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.110860E+09 | 91850810.42 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.366883E+09 | 0.212595E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE6_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.239762E+09 | 0.223073E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.260643E+09 | 0.196198E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.133062E+09 | 0.183052E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.343422E+09 | 0.152094E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.237157E+09 | 0.139270E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.208933E+09 | 0.111906E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.254026E+09 | 0.109163E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.348540E+09 | 0.119122E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.439251E+09 | 0.145677E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.305503E+09 | 0.180031E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.201911E+09 | 0.200082E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.162262E+09 | 0.252441E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.313447E+10 | 0.201211E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.133062E+09 | 0.109163E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.439251E+09 | 0.252441E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200711E+09 | 0.184940E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.218190E+09 | 0.162645E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.111555E+09 | 0.151442E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.287980E+09 | 0.125387E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.199424E+09 | 0.114497E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.175995E+09 | 91866069.76 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.213103E+09 | 90191055.15 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291695E+09 | 98847322.21 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.367748E+09 | 0.120630E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.256180E+09 | 0.148425E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.169010E+09 | 0.166004E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135835E+09 | 0.209630E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.262743E+10 | 0.166450E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.111555E+09 | 90191055.15 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.367748E+09 | 0.209630E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.200711E+09 | 0.184940E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.218190E+09 | 0.162645E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.111555E+09 | 0.151442E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.287980E+09 | 0.125387E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.199424E+09 | 0.114497E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.175995E+09 | 91866069.76 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.213103E+09 | 90191055.15 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.291695E+09 | 98847322.21 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.367748E+09 | 0.120630E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.256180E+09 | 0.148425E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.169010E+09 | 0.166004E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.135835E+09 | 0.209630E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.262743E+10 | 0.166450E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.111555E+09 | 90191055.15 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.367748E+09 | 0.209630E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE7_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.240496E+09 | 0.219814E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.261451E+09 | 0.193180E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.133906E+09 | 0.180001E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.345017E+09 | 0.149087E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.239170E+09 | 0.135969E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.211037E+09 | 0.109151E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.255358E+09 | 0.107199E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.349295E+09 | 0.117596E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.440291E+09 | 0.143474E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.306786E+09 | 0.176440E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.202489E+09 | 0.197244E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.162798E+09 | 0.248906E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.314809E+10 | 0.197806E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.133906E+09 | 0.107199E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.440291E+09 | 0.248906E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.202669E+09 | 0.175468E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.220381E+09 | 0.153474E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.113956E+09 | 0.142329E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.290831E+09 | 0.117924E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.203248E+09 | 0.106079E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.180193E+09 | 84866232.93 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.215970E+09 | 84526249.69 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.293569E+09 | 93733606.81 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.370055E+09 | 0.114253E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.258591E+09 | 0.139958E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.170584E+09 | 0.157578E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.137220E+09 | 0.199148E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.265727E+10 | 0.156934E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.113956E+09 | 84526249.69 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.370055E+09 | 0.199148E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_WINDOW_2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.207804E+09 | 0.134500E+09 | 73304068.41 | 0.202669E+09 | 0.175468E+09 |
February | 0.229307E+09 | 0.139931E+09 | 89376690.89 | 0.220381E+09 | 0.153474E+09 |
March | 0.156988E+09 | 45730722.64 | 0.111257E+09 | 0.113956E+09 | 0.142329E+09 |
April | 0.315448E+09 | 0.142596E+09 | 0.172852E+09 | 0.290831E+09 | 0.117924E+09 |
May | 0.269535E+09 | 87724495.05 | 0.181810E+09 | 0.203248E+09 | 0.106079E+09 |
June | 0.240291E+09 | 58138134.90 | 0.182153E+09 | 0.180193E+09 | 84866232.93 |
July | 0.269027E+09 | 84220443.19 | 0.184806E+09 | 0.215970E+09 | 84526249.69 |
August | 0.315280E+09 | 0.141820E+09 | 0.173460E+09 | 0.293569E+09 | 93733606.81 |
September | 0.360699E+09 | 0.211357E+09 | 0.149342E+09 | 0.370055E+09 | 0.114253E+09 |
October | 0.256042E+09 | 0.149669E+09 | 0.106373E+09 | 0.258591E+09 | 0.139958E+09 |
November | 0.175596E+09 | 0.106803E+09 | 68792821.08 | 0.170584E+09 | 0.157578E+09 |
December | 0.143797E+09 | 92112206.48 | 51684381.78 | 0.137220E+09 | 0.199148E+09 |
Annual Sum or Average | 0.293981E+10 | 0.139460E+10 | 0.154521E+10 | 0.265727E+10 | 0.156934E+10 |
Minimum of Months | 0.143797E+09 | 45730722.64 | 51684381.78 | 0.113956E+09 | 84526249.69 |
Maximum of Months | 0.360699E+09 | 0.211357E+09 | 0.184806E+09 | 0.370055E+09 | 0.199148E+09 |
Report: WindowEnergyReportMonthly
For: SMSTORE8_WALL_1_DOOR
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.248818E+09 | 0.161046E+09 | 87771976.65 | 0.242875E+09 | 0.208508E+09 |
February | 0.274565E+09 | 0.167549E+09 | 0.107017E+09 | 0.264109E+09 | 0.182251E+09 |
March | 0.187972E+09 | 54756523.16 | 0.133216E+09 | 0.136830E+09 | 0.169137E+09 |
April | 0.377707E+09 | 0.170740E+09 | 0.206968E+09 | 0.348450E+09 | 0.140215E+09 |
May | 0.322732E+09 | 0.105039E+09 | 0.217694E+09 | 0.243764E+09 | 0.126004E+09 |
June | 0.287717E+09 | 69612766.79 | 0.218104E+09 | 0.216055E+09 | 0.100863E+09 |
July | 0.322124E+09 | 0.100843E+09 | 0.221281E+09 | 0.258792E+09 | 0.100494E+09 |
August | 0.377507E+09 | 0.169811E+09 | 0.207695E+09 | 0.351549E+09 | 0.111537E+09 |
September | 0.431889E+09 | 0.253072E+09 | 0.178817E+09 | 0.443056E+09 | 0.135914E+09 |
October | 0.306576E+09 | 0.179209E+09 | 0.127367E+09 | 0.309681E+09 | 0.166373E+09 |
November | 0.210253E+09 | 0.127882E+09 | 82370351.56 | 0.204394E+09 | 0.187203E+09 |
December | 0.172177E+09 | 0.110292E+09 | 61885246.61 | 0.164476E+09 | 0.236414E+09 |
Annual Sum or Average | 0.352004E+10 | 0.166985E+10 | 0.185019E+10 | 0.318403E+10 | 0.186491E+10 |
Minimum of Months | 0.172177E+09 | 54756523.16 | 61885246.61 | 0.136830E+09 | 0.100494E+09 |
Maximum of Months | 0.431889E+09 | 0.253072E+09 | 0.221281E+09 | 0.443056E+09 | 0.236414E+09 |
Report: WindowZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 476.83 | 460.83 | 497.16 | 321.78 | 175.38 | 0.00 | 0.00 |
February | 574.76 | 446.44 | 607.38 | 370.64 | 236.74 | 0.00 | 0.00 |
March | 263.93 | 376.94 | 375.58 | 109.41 | 266.18 | 0.00 | 0.00 |
April | 702.41 | 327.71 | 779.84 | 352.52 | 427.32 | 0.00 | 0.00 |
May | 466.25 | 291.69 | 644.84 | 209.88 | 434.97 | 0.00 | 0.00 |
June | 427.27 | 236.41 | 594.04 | 143.73 | 450.31 | 0.00 | 0.00 |
July | 506.21 | 219.84 | 643.63 | 201.49 | 442.14 | 0.00 | 0.00 |
August | 696.44 | 238.17 | 754.29 | 339.30 | 414.99 | 0.00 | 0.00 |
September | 906.36 | 303.68 | 891.71 | 522.51 | 369.20 | 0.00 | 0.00 |
October | 606.20 | 376.99 | 612.56 | 358.07 | 254.49 | 0.00 | 0.00 |
November | 415.10 | 427.06 | 434.10 | 264.04 | 170.07 | 0.00 | 0.00 |
December | 322.34 | 521.39 | 344.02 | 220.37 | 123.65 | 0.00 | 0.00 |
Annual Sum or Average | 529.07 | 351.80 | 597.35 | 283.37 | 313.98 | 0.00 | 0.00 |
Minimum of Months | 263.93 | 219.84 | 344.02 | 109.41 | 123.65 | 0.00 | 0.00 |
Maximum of Months | 906.36 | 521.39 | 891.71 | 522.51 | 450.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 235.88 | 242.58 | 248.58 | 160.89 | 87.69 | 0.00 | 0.00 |
February | 284.60 | 235.54 | 303.69 | 185.32 | 118.37 | 0.00 | 0.00 |
March | 129.04 | 200.43 | 187.79 | 54.70 | 133.09 | 0.00 | 0.00 |
April | 346.06 | 174.06 | 389.92 | 176.26 | 213.66 | 0.00 | 0.00 |
May | 227.96 | 155.01 | 322.42 | 104.94 | 217.48 | 0.00 | 0.00 |
June | 211.16 | 121.57 | 297.02 | 71.86 | 225.16 | 0.00 | 0.00 |
July | 251.58 | 112.27 | 321.81 | 100.75 | 221.07 | 0.00 | 0.00 |
August | 346.92 | 121.25 | 377.14 | 169.65 | 207.50 | 0.00 | 0.00 |
September | 451.50 | 154.87 | 445.86 | 261.26 | 184.60 | 0.00 | 0.00 |
October | 299.82 | 199.63 | 306.28 | 179.04 | 127.24 | 0.00 | 0.00 |
November | 205.15 | 226.75 | 217.05 | 132.02 | 85.03 | 0.00 | 0.00 |
December | 159.49 | 273.95 | 172.01 | 110.19 | 61.83 | 0.00 | 0.00 |
Annual Sum or Average | 261.80 | 184.58 | 298.67 | 141.69 | 156.99 | 0.00 | 0.00 |
Minimum of Months | 129.04 | 112.27 | 172.01 | 54.70 | 61.83 | 0.00 | 0.00 |
Maximum of Months | 451.50 | 273.95 | 445.86 | 261.26 | 225.16 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 236.50 | 234.47 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 285.06 | 227.89 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 129.87 | 193.15 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 347.42 | 169.97 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 229.38 | 152.01 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 211.11 | 123.00 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 250.95 | 114.78 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 346.25 | 124.22 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 450.93 | 156.58 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 300.75 | 193.73 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 205.92 | 217.96 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 159.87 | 265.38 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 262.20 | 180.87 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 129.87 | 114.78 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 450.93 | 265.38 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 237.05 | 231.22 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 285.59 | 224.94 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 130.45 | 190.27 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 348.83 | 166.82 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 230.85 | 149.14 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 211.58 | 122.01 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 251.20 | 114.15 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 346.39 | 123.73 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 451.18 | 155.68 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 301.64 | 190.17 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 206.45 | 214.50 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 160.23 | 262.03 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 262.82 | 178.49 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 130.45 | 114.15 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 451.18 | 262.03 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 237.52 | 229.08 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 286.07 | 223.01 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 130.96 | 188.38 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 350.33 | 164.12 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 232.53 | 146.38 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 212.39 | 120.70 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 251.71 | 113.16 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 346.74 | 122.82 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 451.60 | 154.56 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 302.53 | 187.27 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 206.88 | 212.34 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 160.58 | 259.62 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 263.52 | 176.56 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 130.96 | 113.16 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 451.60 | 259.62 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 478.19 | 448.29 | 496.14 | 321.12 | 175.02 | 0.00 | 0.00 |
February | 575.48 | 436.58 | 606.13 | 369.88 | 236.25 | 0.00 | 0.00 |
March | 265.10 | 368.45 | 374.81 | 109.18 | 265.63 | 0.00 | 0.00 |
April | 705.60 | 318.78 | 778.24 | 351.80 | 426.44 | 0.00 | 0.00 |
May | 470.16 | 283.04 | 643.52 | 209.44 | 434.08 | 0.00 | 0.00 |
June | 427.85 | 234.94 | 592.82 | 143.43 | 449.39 | 0.00 | 0.00 |
July | 504.78 | 221.09 | 642.31 | 201.08 | 441.23 | 0.00 | 0.00 |
August | 694.25 | 240.55 | 752.74 | 338.60 | 414.14 | 0.00 | 0.00 |
September | 904.72 | 303.67 | 889.88 | 521.44 | 368.44 | 0.00 | 0.00 |
October | 608.46 | 364.27 | 611.31 | 357.34 | 253.97 | 0.00 | 0.00 |
November | 416.14 | 415.47 | 433.21 | 263.49 | 169.72 | 0.00 | 0.00 |
December | 323.63 | 506.27 | 343.32 | 219.92 | 123.40 | 0.00 | 0.00 |
Annual Sum or Average | 529.93 | 344.66 | 596.12 | 282.79 | 313.33 | 0.00 | 0.00 |
Minimum of Months | 265.10 | 221.09 | 343.32 | 109.18 | 123.40 | 0.00 | 0.00 |
Maximum of Months | 904.72 | 506.27 | 889.88 | 521.44 | 449.39 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 238.69 | 224.40 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 287.28 | 218.63 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 132.18 | 184.24 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 352.90 | 158.66 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 235.31 | 140.92 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 214.16 | 116.95 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 252.61 | 110.06 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 347.17 | 119.77 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 452.16 | 151.49 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 304.02 | 181.73 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 207.74 | 208.02 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 161.51 | 254.02 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 264.85 | 172.18 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 132.18 | 110.06 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 452.16 | 254.02 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 238.94 | 223.42 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 287.57 | 217.66 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 132.46 | 183.34 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 353.67 | 157.38 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 236.20 | 139.58 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 215.05 | 115.85 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 253.14 | 109.34 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 347.47 | 119.25 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 452.55 | 150.71 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 304.55 | 180.30 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 207.94 | 207.12 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 161.68 | 253.00 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 265.31 | 171.18 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 132.46 | 109.34 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 452.55 | 253.00 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 239.66 | 220.17 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 288.46 | 214.32 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 133.29 | 180.29 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 355.32 | 154.27 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 238.21 | 136.26 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 217.22 | 112.99 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 254.47 | 107.37 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 348.22 | 117.72 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 453.62 | 148.43 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 305.83 | 176.71 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 208.53 | 204.19 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 162.21 | 249.46 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 266.46 | 168.29 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 133.29 | 107.37 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 453.62 | 249.46 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 242.01 | 208.87 | 248.07 | 160.56 | 87.51 | 0.00 | 0.00 |
February | 291.37 | 202.21 | 303.07 | 184.94 | 118.13 | 0.00 | 0.00 |
March | 136.18 | 169.43 | 187.41 | 54.59 | 132.81 | 0.00 | 0.00 |
April | 358.84 | 145.09 | 389.12 | 175.90 | 213.22 | 0.00 | 0.00 |
May | 242.78 | 126.26 | 321.76 | 104.72 | 217.04 | 0.00 | 0.00 |
June | 222.39 | 104.40 | 296.41 | 71.72 | 224.69 | 0.00 | 0.00 |
July | 257.89 | 100.64 | 321.15 | 100.54 | 220.61 | 0.00 | 0.00 |
August | 350.47 | 111.64 | 376.37 | 169.30 | 207.07 | 0.00 | 0.00 |
September | 456.47 | 140.59 | 444.94 | 260.72 | 184.22 | 0.00 | 0.00 |
October | 308.72 | 166.63 | 305.65 | 178.67 | 126.98 | 0.00 | 0.00 |
November | 210.48 | 193.81 | 216.61 | 131.75 | 84.86 | 0.00 | 0.00 |
December | 163.87 | 236.97 | 171.66 | 109.96 | 61.70 | 0.00 | 0.00 |
Annual Sum or Average | 269.49 | 158.66 | 298.06 | 141.40 | 156.67 | 0.00 | 0.00 |
Minimum of Months | 136.18 | 100.64 | 171.66 | 54.59 | 61.70 | 0.00 | 0.00 |
Maximum of Months | 456.47 | 236.97 | 444.94 | 260.72 | 224.69 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.127715E+10 | 0.123429E+10 | 0.133159E+10 | 0.861863E+09 | 0.469725E+09 | 0.00 | 0.00 |
February | 0.139047E+10 | 0.108002E+10 | 0.146938E+10 | 0.896661E+09 | 0.572716E+09 | 0.00 | 0.00 |
March | 0.706919E+09 | 0.100960E+10 | 0.100596E+10 | 0.293038E+09 | 0.712924E+09 | 0.00 | 0.00 |
April | 0.182064E+10 | 0.849414E+09 | 0.202136E+10 | 0.913739E+09 | 0.110762E+10 | 0.00 | 0.00 |
May | 0.124881E+10 | 0.781270E+09 | 0.172715E+10 | 0.562129E+09 | 0.116502E+10 | 0.00 | 0.00 |
June | 0.110747E+10 | 0.612771E+09 | 0.153976E+10 | 0.372543E+09 | 0.116722E+10 | 0.00 | 0.00 |
July | 0.135583E+10 | 0.588813E+09 | 0.172389E+10 | 0.539676E+09 | 0.118422E+10 | 0.00 | 0.00 |
August | 0.186535E+10 | 0.637908E+09 | 0.202028E+10 | 0.908771E+09 | 0.111151E+10 | 0.00 | 0.00 |
September | 0.234929E+10 | 0.787128E+09 | 0.231132E+10 | 0.135435E+10 | 0.956967E+09 | 0.00 | 0.00 |
October | 0.162363E+10 | 0.100974E+10 | 0.164069E+10 | 0.959064E+09 | 0.681625E+09 | 0.00 | 0.00 |
November | 0.107593E+10 | 0.110694E+10 | 0.112520E+10 | 0.684381E+09 | 0.440817E+09 | 0.00 | 0.00 |
December | 0.863348E+09 | 0.139650E+10 | 0.921433E+09 | 0.590245E+09 | 0.331188E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.166849E+11 | 0.110944E+11 | 0.188380E+11 | 0.893646E+10 | 0.990155E+10 | 0.00 | 0.00 |
Minimum of Months | 0.706919E+09 | 0.588813E+09 | 0.921433E+09 | 0.293038E+09 | 0.331188E+09 | 0.00 | 0.00 |
Maximum of Months | 0.234929E+10 | 0.139650E+10 | 0.231132E+10 | 0.135435E+10 | 0.118422E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.631789E+09 | 0.649726E+09 | 0.665794E+09 | 0.430932E+09 | 0.234862E+09 | 0.00 | 0.00 |
February | 0.688497E+09 | 0.569807E+09 | 0.734689E+09 | 0.448330E+09 | 0.286358E+09 | 0.00 | 0.00 |
March | 0.345628E+09 | 0.536827E+09 | 0.502981E+09 | 0.146519E+09 | 0.356462E+09 | 0.00 | 0.00 |
April | 0.896982E+09 | 0.451157E+09 | 0.101068E+10 | 0.456869E+09 | 0.553810E+09 | 0.00 | 0.00 |
May | 0.610569E+09 | 0.415190E+09 | 0.863575E+09 | 0.281065E+09 | 0.582511E+09 | 0.00 | 0.00 |
June | 0.547332E+09 | 0.315111E+09 | 0.769879E+09 | 0.186272E+09 | 0.583608E+09 | 0.00 | 0.00 |
July | 0.673823E+09 | 0.300694E+09 | 0.861947E+09 | 0.269838E+09 | 0.592109E+09 | 0.00 | 0.00 |
August | 0.929188E+09 | 0.324766E+09 | 0.101014E+10 | 0.454385E+09 | 0.555756E+09 | 0.00 | 0.00 |
September | 0.117029E+10 | 0.401434E+09 | 0.115566E+10 | 0.677176E+09 | 0.478483E+09 | 0.00 | 0.00 |
October | 0.803050E+09 | 0.534679E+09 | 0.820345E+09 | 0.479532E+09 | 0.340813E+09 | 0.00 | 0.00 |
November | 0.531750E+09 | 0.587728E+09 | 0.562599E+09 | 0.342191E+09 | 0.220409E+09 | 0.00 | 0.00 |
December | 0.427167E+09 | 0.733749E+09 | 0.460717E+09 | 0.295123E+09 | 0.165594E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.825607E+10 | 0.582087E+10 | 0.941900E+10 | 0.446823E+10 | 0.495077E+10 | 0.00 | 0.00 |
Minimum of Months | 0.345628E+09 | 0.300694E+09 | 0.460717E+09 | 0.146519E+09 | 0.165594E+09 | 0.00 | 0.00 |
Maximum of Months | 0.117029E+10 | 0.733749E+09 | 0.115566E+10 | 0.677176E+09 | 0.592109E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.633450E+09 | 0.628010E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.689627E+09 | 0.551304E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.347836E+09 | 0.517334E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.900506E+09 | 0.440571E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.614382E+09 | 0.407156E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.547210E+09 | 0.318808E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.672139E+09 | 0.307431E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.927392E+09 | 0.332698E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.116880E+10 | 0.405859E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.805532E+09 | 0.518894E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.533734E+09 | 0.564946E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.428206E+09 | 0.710783E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.826881E+10 | 0.570380E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.347836E+09 | 0.307431E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.116880E+10 | 0.710783E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.634924E+09 | 0.619310E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.690907E+09 | 0.544185E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.349384E+09 | 0.509628E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.904174E+09 | 0.432401E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.618314E+09 | 0.399462E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.548403E+09 | 0.316251E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.672817E+09 | 0.305740E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.927783E+09 | 0.331386E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.116946E+10 | 0.403514E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.807910E+09 | 0.509341E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.535125E+09 | 0.555978E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.429164E+09 | 0.701817E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.828836E+10 | 0.562901E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.349384E+09 | 0.305740E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.116946E+10 | 0.701817E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.636186E+09 | 0.613561E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.692065E+09 | 0.539509E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.350773E+09 | 0.504556E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.908043E+09 | 0.425390E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.622819E+09 | 0.392056E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.550505E+09 | 0.312854E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.674169E+09 | 0.303100E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.928715E+09 | 0.328951E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.117056E+10 | 0.400626E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.810288E+09 | 0.501580E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.536244E+09 | 0.550378E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.430096E+09 | 0.695367E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.831046E+10 | 0.556793E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.350773E+09 | 0.303100E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.117056E+10 | 0.695367E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.128078E+10 | 0.120069E+10 | 0.132885E+10 | 0.860093E+09 | 0.468760E+09 | 0.00 | 0.00 |
February | 0.139220E+10 | 0.105618E+10 | 0.146636E+10 | 0.894820E+09 | 0.571540E+09 | 0.00 | 0.00 |
March | 0.710038E+09 | 0.986856E+09 | 0.100390E+10 | 0.292436E+09 | 0.711460E+09 | 0.00 | 0.00 |
April | 0.182892E+10 | 0.826284E+09 | 0.201721E+10 | 0.911862E+09 | 0.110534E+10 | 0.00 | 0.00 |
May | 0.125928E+10 | 0.758104E+09 | 0.172360E+10 | 0.560975E+09 | 0.116263E+10 | 0.00 | 0.00 |
June | 0.110898E+10 | 0.608974E+09 | 0.153660E+10 | 0.371778E+09 | 0.116482E+10 | 0.00 | 0.00 |
July | 0.135201E+10 | 0.592177E+09 | 0.172035E+10 | 0.538568E+09 | 0.118179E+10 | 0.00 | 0.00 |
August | 0.185949E+10 | 0.644300E+09 | 0.201614E+10 | 0.906905E+09 | 0.110923E+10 | 0.00 | 0.00 |
September | 0.234504E+10 | 0.787102E+09 | 0.230657E+10 | 0.135157E+10 | 0.955002E+09 | 0.00 | 0.00 |
October | 0.162969E+10 | 0.975667E+09 | 0.163732E+10 | 0.957094E+09 | 0.680226E+09 | 0.00 | 0.00 |
November | 0.107865E+10 | 0.107689E+10 | 0.112289E+10 | 0.682976E+09 | 0.439912E+09 | 0.00 | 0.00 |
December | 0.866817E+09 | 0.135599E+10 | 0.919541E+09 | 0.589033E+09 | 0.330508E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.167119E+11 | 0.108692E+11 | 0.187993E+11 | 0.891811E+10 | 0.988122E+10 | 0.00 | 0.00 |
Minimum of Months | 0.710038E+09 | 0.592177E+09 | 0.919541E+09 | 0.292436E+09 | 0.330508E+09 | 0.00 | 0.00 |
Maximum of Months | 0.234504E+10 | 0.135599E+10 | 0.230657E+10 | 0.135157E+10 | 0.118179E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.639310E+09 | 0.601023E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.694997E+09 | 0.528901E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.354025E+09 | 0.493458E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.914718E+09 | 0.411244E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.630262E+09 | 0.377433E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.555114E+09 | 0.303131E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.676596E+09 | 0.294796E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.929861E+09 | 0.320800E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.117200E+10 | 0.392657E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.814282E+09 | 0.486736E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.538459E+09 | 0.539185E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.432596E+09 | 0.680379E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.835222E+10 | 0.542974E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.354025E+09 | 0.294796E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.117200E+10 | 0.680379E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.639971E+09 | 0.598415E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.695688E+09 | 0.526556E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.354782E+09 | 0.491061E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.916719E+09 | 0.407931E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.632647E+09 | 0.373838E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.557409E+09 | 0.300289E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.678011E+09 | 0.292865E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.930675E+09 | 0.319394E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.117302E+10 | 0.390652E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.815719E+09 | 0.482922E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.538975E+09 | 0.536854E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.433048E+09 | 0.677632E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.836666E+10 | 0.539841E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.354782E+09 | 0.292865E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.117302E+10 | 0.677632E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.641918E+09 | 0.589695E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.697830E+09 | 0.518471E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.357015E+09 | 0.482884E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.920977E+09 | 0.399862E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.638018E+09 | 0.364962E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.563027E+09 | 0.292883E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.681565E+09 | 0.287581E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.932684E+09 | 0.315290E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.117579E+10 | 0.384734E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.819146E+09 | 0.473289E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.540508E+09 | 0.529251E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.434467E+09 | 0.668165E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.840294E+10 | 0.530707E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.357015E+09 | 0.287581E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.117579E+10 | 0.668165E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.648212E+09 | 0.559443E+09 | 0.664427E+09 | 0.430047E+09 | 0.234380E+09 | 0.00 | 0.00 |
February | 0.704871E+09 | 0.489198E+09 | 0.733180E+09 | 0.447410E+09 | 0.285770E+09 | 0.00 | 0.00 |
March | 0.364742E+09 | 0.453795E+09 | 0.501948E+09 | 0.146218E+09 | 0.355730E+09 | 0.00 | 0.00 |
April | 0.930112E+09 | 0.376062E+09 | 0.100860E+10 | 0.455931E+09 | 0.552672E+09 | 0.00 | 0.00 |
May | 0.650260E+09 | 0.338161E+09 | 0.861802E+09 | 0.280488E+09 | 0.581314E+09 | 0.00 | 0.00 |
June | 0.576441E+09 | 0.270595E+09 | 0.768298E+09 | 0.185889E+09 | 0.582409E+09 | 0.00 | 0.00 |
July | 0.690732E+09 | 0.269546E+09 | 0.860177E+09 | 0.269284E+09 | 0.590893E+09 | 0.00 | 0.00 |
August | 0.938688E+09 | 0.299004E+09 | 0.100807E+10 | 0.453452E+09 | 0.554615E+09 | 0.00 | 0.00 |
September | 0.118317E+10 | 0.364419E+09 | 0.115329E+10 | 0.675785E+09 | 0.477501E+09 | 0.00 | 0.00 |
October | 0.826864E+09 | 0.446288E+09 | 0.818660E+09 | 0.478547E+09 | 0.340113E+09 | 0.00 | 0.00 |
November | 0.545562E+09 | 0.502359E+09 | 0.561444E+09 | 0.341488E+09 | 0.219956E+09 | 0.00 | 0.00 |
December | 0.438916E+09 | 0.634710E+09 | 0.459771E+09 | 0.294517E+09 | 0.165254E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.849857E+10 | 0.500358E+10 | 0.939966E+10 | 0.445906E+10 | 0.494061E+10 | 0.00 | 0.00 |
Minimum of Months | 0.364742E+09 | 0.269546E+09 | 0.459771E+09 | 0.146218E+09 | 0.165254E+09 | 0.00 | 0.00 |
Maximum of Months | 0.118317E+10 | 0.634710E+09 | 0.115329E+10 | 0.675785E+09 | 0.590893E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 4.18 | 3.24 | 2.03 | 1.05 | -4.0 | 28.28 | 62.93 | 0.00 |
February | 4.25 | 3.55 | 2.74 | 1.60 | -5.0 | 43.80 | 86.73 | 0.02 |
March | 5.90 | 4.45 | 2.76 | 1.18 | -2.0 | 68.95 | 35.00 | 0.00 |
April | 8.96 | 6.23 | 3.38 | 1.56 | -0.7 | 96.13 | 186.12 | 0.00 |
May | 9.99 | 8.06 | 6.28 | 3.35 | -0.9 | 110.92 | 199.68 | 0.02 |
June | 13.31 | 11.26 | 9.70 | 3.33 | 3.35 | 121.69 | 199.28 | 0.00 |
July | 15.02 | 12.39 | 10.49 | 3.21 | 4.48 | 111.91 | 220.83 | 0.00 |
August | 15.65 | 12.74 | 10.65 | 2.92 | 3.94 | 91.47 | 211.91 | 0.00 |
September | 13.43 | 11.01 | 9.10 | 2.64 | 1.42 | 68.72 | 198.32 | 0.01 |
October | 9.33 | 8.03 | 6.81 | 1.97 | -1.0 | 48.92 | 91.86 | 0.04 |
November | 6.66 | 5.65 | 4.54 | 2.05 | -2.3 | 30.27 | 53.24 | 0.04 |
December | 4.10 | 3.14 | 1.95 | 2.36 | -5.1 | 20.52 | 40.74 | 0.04 |
Annual Sum or Average | 9.26 | 7.50 | 5.89 | 2.27 | -0.6 | 70.25 | 132.30 | 0.02 |
Minimum of Months | 4.10 | 3.14 | 1.95 | 1.05 | -5.1 | 20.52 | 35.00 | 0.00 |
Maximum of Months | 15.65 | 12.74 | 10.65 | 3.35 | 4.48 | 121.69 | 220.83 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 29-JAN-05:00 | 9.36 | 5.00 | 3.60 | 8.35 | 0.00 | 0.00 |
February | 11.00 | 07-FEB-14:00 | 9.86 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 14.00 | 25-MAR-12:00 | 11.21 | 9.00 | 2.60 | 7.35 | 287.00 | 93.00 |
April | 24.00 | 30-APR-14:00 | 13.10 | 4.00 | 1.50 | 7.75 | 167.50 | 716.00 |
May | 24.00 | 22-MAY-14:00 | 16.06 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 27.00 | 13-JUN-16:00 | 17.51 | 12.00 | 3.10 | 12.41 | 141.50 | 652.50 |
July | 30.00 | 22-JUL-17:00 | 16.77 | 8.00 | 0.00 | 14.28 | 122.00 | 407.00 |
August | 27.00 | 14-AUG-17:19 | 14.15 | 3.33 | 2.60 | 10.37 | 133.00 | 358.83 |
September | 23.00 | 11-SEP-16:00 | 16.21 | 12.00 | 2.60 | 8.74 | 108.00 | 325.50 |
October | 19.00 | 07-OCT-14:00 | 10.08 | 1.00 | 1.50 | 2.22 | 131.00 | 540.50 |
November | 16.00 | 24-NOV-11:00 | 12.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 13.00 | 23-DEC-10:00 | 7.62 | 2.00 | 7.70 | 6.75 | 70.50 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 11.00 | 7.62 | 1.00 | 0.00 | 2.22 | 0.00 | 0.00 | |
Maximum of Months | 30.00 | 17.51 | 12.00 | 7.70 | 14.28 | 287.00 | 769.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -6.0 | 10-JAN-07:00 | -6.9 | -9.0 | 0.00 | -20.0 | 0.00 | 0.00 |
February | -4.0 | 17-FEB-06:00 | -4.0 | -4.0 | 0.00 | -20.5 | 0.00 | 0.00 |
March | -1.0 | 08-MAR-06:00 | -1.4 | -2.0 | 0.00 | -14.4 | 17.50 | 184.50 |
April | 0.00 | 08-APR-04:00 | -0.8 | -2.0 | 0.00 | -12.7 | 0.00 | 0.00 |
May | 2.00 | 06-MAY-04:00 | 1.57 | 1.00 | 3.60 | -13.7 | 12.50 | 117.00 |
June | 6.00 | 01-JUN-03:00 | 5.04 | 4.00 | 0.00 | -9.2 | 0.00 | 0.00 |
July | 7.00 | 05-JUL-04:00 | 6.47 | 6.00 | 3.10 | -7.8 | 28.00 | 155.00 |
August | 8.00 | 20-AUG-04:00 | 7.45 | 7.00 | 0.00 | -6.6 | 0.00 | 0.00 |
September | 5.00 | 20-SEP-03:00 | 5.00 | 5.00 | 2.60 | -10.0 | 0.00 | 0.00 |
October | 2.00 | 07-OCT-03:00 | 2.00 | 2.00 | 0.00 | -13.4 | 0.00 | 0.00 |
November | -2.0 | 29-NOV-01:00 | -2.0 | -2.0 | 3.10 | -10.7 | 0.00 | 0.00 |
December | -3.0 | 29-DEC-20:00 | -4.4 | -7.0 | 3.60 | -20.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -6.0 | -6.9 | -9.0 | 0.00 | -20.5 | 0.00 | 0.00 | |
Maximum of Months | 8.00 | 7.45 | 7.00 | 3.60 | -6.6 | 28.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.44 | 29-JAN-04:00 | 13.00 | 12.00 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.86 | 07-FEB-14:00 | 11.00 | 9.00 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.39 | 28-APR-07:00 | 16.00 | 15.00 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 16.06 | 22-MAY-14:00 | 24.00 | 11.00 | 2.60 | 9.33 | 159.00 | 769.00 |
June | 19.93 | 25-JUN-17:00 | 22.00 | 19.00 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 17.29 | 22-JUL-09:00 | 26.00 | 12.00 | 4.60 | 11.46 | 224.50 | 619.50 |
August | 17.04 | 14-AUG-12:00 | 24.00 | 13.00 | 2.60 | 9.91 | 205.50 | 669.50 |
September | 16.53 | 10-SEP-15:00 | 21.00 | 14.00 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.58 | 17-OCT-14:00 | 16.00 | 12.00 | 0.00 | 12.03 | 144.00 | 44.50 |
November | 12.00 | 24-NOV-11:00 | 16.00 | 9.00 | 4.10 | 9.33 | 61.50 | 0.00 |
December | 7.93 | 02-DEC-12:00 | 9.00 | 7.00 | 0.00 | 2.01 | 135.50 | 84.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.93 | 9.00 | 7.00 | 0.00 | 2.01 | 0.00 | 0.00 | |
Maximum of Months | 19.93 | 26.00 | 19.00 | 4.60 | 15.94 | 224.50 | 769.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.00 | 29-JAN-04:00 | 13.00 | 12.44 | 0.00 | 9.13 | 0.00 | 0.00 |
February | 9.00 | 07-FEB-14:00 | 11.00 | 9.86 | 2.10 | 6.35 | 138.00 | 225.00 |
March | 12.00 | 19-MAR-11:00 | 12.00 | 12.00 | 2.60 | 8.15 | 131.00 | 0.00 |
April | 15.00 | 28-APR-07:00 | 16.00 | 15.39 | 0.00 | 5.54 | 119.50 | 626.00 |
May | 12.00 | 23-MAY-07:00 | 17.00 | 13.94 | 3.10 | 5.13 | 112.00 | 719.50 |
June | 19.00 | 25-JUN-17:00 | 22.00 | 19.93 | 0.00 | 15.94 | 136.50 | 360.50 |
July | 14.00 | 17-JUL-17:00 | 18.00 | 15.44 | 3.60 | 9.91 | 120.00 | 0.00 |
August | 16.00 | 08-AUG-12:00 | 18.00 | 16.70 | 1.50 | 11.46 | 154.00 | 0.00 |
September | 14.00 | 10-SEP-15:00 | 21.00 | 16.53 | 3.60 | 8.54 | 160.50 | 483.00 |
October | 13.00 | 17-OCT-18:00 | 13.00 | 13.00 | 2.60 | 9.33 | 0.00 | 0.00 |
November | 12.00 | 08-NOV-14:00 | 12.00 | 12.00 | 0.00 | 8.15 | 93.00 | 106.00 |
December | 7.00 | 02-DEC-11:00 | 8.00 | 7.45 | 3.10 | 1.16 | 144.50 | 146.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.00 | 8.00 | 7.45 | 0.00 | 1.16 | 0.00 | 0.00 | |
Maximum of Months | 19.00 | 22.00 | 19.93 | 3.60 | 15.94 | 160.50 | 719.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 10.33 | 8.85 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 10.00 | 14.79 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 10.33 | 17.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 11.26 | 40.86 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 12.54 | 47.73 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 13.82 | 50.98 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 14.77 | 51.67 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 15.12 | 44.67 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 14.78 | 34.25 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 13.84 | 17.71 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 12.55 | 9.34 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 11.27 | 6.14 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 12.57 | 28.73 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 10.00 | 6.14 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 15.12 | 51.67 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.361992E+09 | -238921844.8 | 0.00 | 0.00 | 744.00 | 0.00 | -123070089.8 | 58.99 | 0.00 | 0.00 |
February | 0.329753E+09 | -218406205.1 | 0.00 | 0.00 | 672.00 | 0.00 | -111346726.5 | 58.99 | 0.00 | 0.00 |
March | 0.366810E+09 | -243936308.6 | 0.00 | 0.00 | 744.00 | 0.00 | -122873299.2 | 58.99 | 0.00 | 0.00 |
April | 0.343747E+09 | -228951550.1 | 0.00 | 0.00 | 720.00 | 0.00 | -114795226.0 | 58.99 | 0.00 | 0.00 |
May | 0.347924E+09 | -230439038.3 | 0.00 | 0.00 | 744.00 | 0.00 | -117485079.6 | 58.99 | 0.00 | 0.00 |
June | 0.328865E+09 | -218892884.4 | 0.00 | 0.00 | 720.00 | 0.00 | -109972004.9 | 58.99 | 0.00 | 0.00 |
July | 0.330263E+09 | -217257034.1 | 0.00 | 0.00 | 744.00 | 0.00 | -113005699.1 | 58.99 | 0.00 | 0.00 |
August | 0.332619E+09 | -219767024.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112852292.8 | 58.99 | 0.00 | 0.00 |
September | 0.321877E+09 | -212233787.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109642944.5 | 58.99 | 0.00 | 0.00 |
October | 0.340116E+09 | -221723076.8 | 0.00 | 0.00 | 744.00 | 0.00 | -118392444.3 | 58.99 | 0.00 | 0.00 |
November | 0.338533E+09 | -220048111.9 | 0.00 | 0.00 | 720.00 | 0.00 | -118485190.7 | 58.99 | 0.00 | 0.00 |
December | 0.358034E+09 | -234601548.1 | 0.00 | 0.00 | 744.00 | 0.00 | -123432771.3 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.410053E+10 | -.270518E+10 | 8760.00 | -.139535E+10 | 58.99 | |||||
Minimum of Months | 0.321877E+09 | -243936308.6 | 0.00 | 0.00 | 672.00 | 0.00 | -123432771.3 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.366810E+09 | -212233787.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109642944.5 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.359587E+09 | -238917567.6 | 0.00 | 0.00 | 744.00 | 0.00 | -120669477.9 | 58.99 | 0.00 | 0.00 |
February | 0.327571E+09 | -218407122.2 | 0.00 | 0.00 | 672.00 | 0.00 | -109163779.6 | 58.99 | 0.00 | 0.00 |
March | 0.364283E+09 | -243942945.5 | 0.00 | 0.00 | 744.00 | 0.00 | -120339738.9 | 58.99 | 0.00 | 0.00 |
April | 0.341089E+09 | -228944676.5 | 0.00 | 0.00 | 720.00 | 0.00 | -112144398.8 | 58.99 | 0.00 | 0.00 |
May | 0.345453E+09 | -230443962.8 | 0.00 | 0.00 | 744.00 | 0.00 | -115008964.7 | 58.99 | 0.00 | 0.00 |
June | 0.328110E+09 | -218891983.4 | 0.00 | 0.00 | 720.00 | 0.00 | -109218490.2 | 58.99 | 0.00 | 0.00 |
July | 0.329784E+09 | -217254722.9 | 0.00 | 0.00 | 744.00 | 0.00 | -112529489.7 | 58.99 | 0.00 | 0.00 |
August | 0.332234E+09 | -219767529.8 | 0.00 | 0.00 | 744.00 | 0.00 | -112466224.0 | 58.99 | 0.00 | 0.00 |
September | 0.321341E+09 | -212230572.6 | 0.00 | 0.00 | 720.00 | 0.00 | -109110573.3 | 58.99 | 0.00 | 0.00 |
October | 0.337572E+09 | -221713970.0 | 0.00 | 0.00 | 744.00 | 0.00 | -115858077.9 | 58.99 | 0.00 | 0.00 |
November | 0.335888E+09 | -220049345.3 | 0.00 | 0.00 | 720.00 | 0.00 | -115838633.9 | 58.99 | 0.00 | 0.00 |
December | 0.355744E+09 | -234598677.6 | 0.00 | 0.00 | 744.00 | 0.00 | -121145638.6 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.407866E+10 | -.270516E+10 | 8760.00 | -.137349E+10 | 58.99 | |||||
Minimum of Months | 0.321341E+09 | -243942945.5 | 0.00 | 0.00 | 672.00 | 0.00 | -121145638.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.364283E+09 | -212230572.6 | 0.00 | 0.00 | 744.00 | 0.00 | -109110573.3 | 58.99 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.332792E+09 | -210100899.9 | 0.00 | 0.00 | 744.00 | 0.00 | -122690862.6 | 58.99 | 0.00 | 0.00 |
February | 0.303085E+09 | -192216043.5 | 0.00 | 0.00 | 672.00 | 0.00 | -110868574.3 | 58.99 | 0.00 | 0.00 |
March | 0.340149E+09 | -217871484.0 | 0.00 | 0.00 | 744.00 | 0.00 | -122277045.3 | 59.00 | 0.00 | 0.00 |
April | 0.314616E+09 | -201210585.7 | 0.00 | 0.00 | 720.00 | 0.00 | -113405064.3 | 58.98 | 0.00 | 0.00 |
May | 0.320400E+09 | -204354289.9 | 0.00 | 0.00 | 744.00 | 0.00 | -116045843.7 | 58.99 | 0.00 | 0.00 |
June | 0.304010E+09 | -195098545.0 | 0.00 | 0.00 | 720.00 | 0.00 | -108911660.3 | 58.99 | 0.00 | 0.00 |
July | 0.301609E+09 | -189798409.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111810361.2 | 58.99 | 0.00 | 0.00 |
August | 0.308152E+09 | -196443259.5 | 0.00 | 0.00 | 744.00 | 0.00 | -111708814.2 | 58.99 | 0.00 | 0.00 |
September | 0.295091E+09 | -186382199.8 | 0.00 | 0.00 | 720.00 | 0.00 | -108709273.0 | 58.99 | 0.00 | 0.00 |
October | 0.312429E+09 | -194973895.8 | 0.00 | 0.00 | 744.00 | 0.00 | -117455552.4 | 58.99 | 0.00 | 0.00 |
November | 0.312233E+09 | -194275513.2 | 0.00 | 0.00 | 720.00 | 0.00 | -117957297.9 | 59.00 | 0.00 | 0.00 |
December | 0.327893E+09 | -204812314.6 | 0.00 | 0.00 | 744.00 | 0.00 | -123080669.9 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.377246E+10 | -.238754E+10 | 8760.00 | -.138492E+10 | 58.99 | |||||
Minimum of Months | 0.295091E+09 | -217871484.0 | 0.00 | 0.00 | 672.00 | 0.00 | -123080669.9 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.340149E+09 | -186382199.8 | 0.00 | 0.00 | 744.00 | 0.00 | -108709273.0 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.333285E+09 | -210101226.9 | 0.00 | 0.00 | 744.00 | 0.00 | -123183295.0 | 58.99 | 0.00 | 0.00 |
February | 0.303494E+09 | -192209258.4 | 0.00 | 0.00 | 672.00 | 0.00 | -111284289.9 | 58.99 | 0.00 | 0.00 |
March | 0.340603E+09 | -217871275.0 | 0.00 | 0.00 | 744.00 | 0.00 | -122731790.1 | 59.00 | 0.00 | 0.00 |
April | 0.315317E+09 | -201182820.8 | 0.00 | 0.00 | 720.00 | 0.00 | -114134250.2 | 59.00 | 0.00 | 0.00 |
May | 0.321070E+09 | -204356132.6 | 0.00 | 0.00 | 744.00 | 0.00 | -116714295.6 | 58.99 | 0.00 | 0.00 |
June | 0.304197E+09 | -195100502.6 | 0.00 | 0.00 | 720.00 | 0.00 | -109096360.3 | 58.99 | 0.00 | 0.00 |
July | 0.301736E+09 | -189793802.1 | 0.00 | 0.00 | 744.00 | 0.00 | -111942455.4 | 58.99 | 0.00 | 0.00 |
August | 0.308223E+09 | -196438914.3 | 0.00 | 0.00 | 744.00 | 0.00 | -111784118.2 | 58.99 | 0.00 | 0.00 |
September | 0.295257E+09 | -186372566.3 | 0.00 | 0.00 | 720.00 | 0.00 | -108884695.9 | 59.00 | 0.00 | 0.00 |
October | 0.313089E+09 | -194981446.5 | 0.00 | 0.00 | 744.00 | 0.00 | -118107860.4 | 58.99 | 0.00 | 0.00 |
November | 0.312740E+09 | -194300688.4 | 0.00 | 0.00 | 720.00 | 0.00 | -118439226.9 | 58.99 | 0.00 | 0.00 |
December | 0.328363E+09 | -204803604.2 | 0.00 | 0.00 | 744.00 | 0.00 | -123559889.6 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.377737E+10 | -.238751E+10 | 8760.00 | -.138986E+10 | 58.99 | |||||
Minimum of Months | 0.295257E+09 | -217871275.0 | 0.00 | 0.00 | 672.00 | 0.00 | -123559889.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.340603E+09 | -186372566.3 | 0.00 | 0.00 | 744.00 | 0.00 | -108884695.9 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.322890E+09 | -198569755.4 | 0.00 | 0.00 | 744.00 | 0.00 | -124320389.2 | 58.99 | 0.00 | 0.00 |
February | 0.294007E+09 | -181758335.6 | 0.00 | 0.00 | 672.00 | 0.00 | -112248594.2 | 59.00 | 0.00 | 0.00 |
March | 0.329918E+09 | -206167711.5 | 0.00 | 0.00 | 744.00 | 0.00 | -123750192.2 | 58.99 | 0.00 | 0.00 |
April | 0.306285E+09 | -190399145.1 | 0.00 | 0.00 | 720.00 | 0.00 | -115885969.2 | 58.99 | 0.00 | 0.00 |
May | 0.311864E+09 | -193265353.1 | 0.00 | 0.00 | 744.00 | 0.00 | -118598178.7 | 58.99 | 0.00 | 0.00 |
June | 0.294722E+09 | -184611018.3 | 0.00 | 0.00 | 720.00 | 0.00 | -110111064.5 | 58.99 | 0.00 | 0.00 |
July | 0.292147E+09 | -179526697.6 | 0.00 | 0.00 | 744.00 | 0.00 | -112619816.8 | 58.98 | 0.00 | 0.00 |
August | 0.298302E+09 | -185887034.4 | 0.00 | 0.00 | 744.00 | 0.00 | -112414739.2 | 58.99 | 0.00 | 0.00 |
September | 0.285932E+09 | -176369075.2 | 0.00 | 0.00 | 720.00 | 0.00 | -109562634.0 | 58.99 | 0.00 | 0.00 |
October | 0.304013E+09 | -184276632.0 | 0.00 | 0.00 | 744.00 | 0.00 | -119735941.3 | 58.99 | 0.00 | 0.00 |
November | 0.302966E+09 | -183504193.9 | 0.00 | 0.00 | 720.00 | 0.00 | -119461810.5 | 58.99 | 0.00 | 0.00 |
December | 0.318482E+09 | -193682255.3 | 0.00 | 0.00 | 744.00 | 0.00 | -124799908.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.366153E+10 | -.225802E+10 | 8760.00 | -.140351E+10 | 58.99 | |||||
Minimum of Months | 0.285932E+09 | -206167711.5 | 0.00 | 0.00 | 672.00 | 0.00 | -124799908.8 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.329918E+09 | -176369075.2 | 0.00 | 0.00 | 744.00 | 0.00 | -109562634.0 | 59.00 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.322930E+09 | -198568986.0 | 0.00 | 0.00 | 744.00 | 0.00 | -124360846.5 | 58.99 | 0.00 | 0.00 |
February | 0.294040E+09 | -181758882.8 | 0.00 | 0.00 | 672.00 | 0.00 | -112280991.1 | 59.00 | 0.00 | 0.00 |
March | 0.329955E+09 | -206170368.4 | 0.00 | 0.00 | 744.00 | 0.00 | -123784473.0 | 58.99 | 0.00 | 0.00 |
April | 0.306460E+09 | -190389684.8 | 0.00 | 0.00 | 720.00 | 0.00 | -116070805.0 | 58.99 | 0.00 | 0.00 |
May | 0.312042E+09 | -193265042.1 | 0.00 | 0.00 | 744.00 | 0.00 | -118776586.7 | 58.99 | 0.00 | 0.00 |
June | 0.294851E+09 | -184611296.8 | 0.00 | 0.00 | 720.00 | 0.00 | -110239869.1 | 58.99 | 0.00 | 0.00 |
July | 0.292276E+09 | -179467942.5 | 0.00 | 0.00 | 744.00 | 0.00 | -112807934.5 | 59.00 | 0.00 | 0.00 |
August | 0.298406E+09 | -185830452.2 | 0.00 | 0.00 | 744.00 | 0.00 | -112575456.7 | 59.01 | 0.00 | 0.00 |
September | 0.285997E+09 | -176382583.2 | 0.00 | 0.00 | 720.00 | 0.00 | -109614853.9 | 58.99 | 0.00 | 0.00 |
October | 0.304119E+09 | -184280721.4 | 0.00 | 0.00 | 744.00 | 0.00 | -119838197.1 | 58.99 | 0.00 | 0.00 |
November | 0.303003E+09 | -183503201.8 | 0.00 | 0.00 | 720.00 | 0.00 | -119499768.0 | 58.99 | 0.00 | 0.00 |
December | 0.318486E+09 | -193682546.9 | 0.00 | 0.00 | 744.00 | 0.00 | -124802962.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.366256E+10 | -.225791E+10 | 8760.00 | -.140465E+10 | 58.99 | |||||
Minimum of Months | 0.285997E+09 | -206170368.4 | 0.00 | 0.00 | 672.00 | 0.00 | -124802962.1 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.329955E+09 | -176382583.2 | 0.00 | 0.00 | 744.00 | 0.00 | -109614853.9 | 59.01 | 0.00 | 0.00 |
Report: WaterHeaterReportMonthly
For: GAS TANK7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.323070E+09 | -198568260.3 | 0.00 | 0.00 | 744.00 | 0.00 | -124502146.5 | 59.00 | 0.00 | 0.00 |
February | 0.294165E+09 | -181768441.6 | 0.00 | 0.00 | 672.00 | 0.00 | -112396071.8 | 58.99 | 0.00 | 0.00 |
March | 0.330080E+09 | -206155611.7 | 0.00 | 0.00 | 744.00 | 0.00 | -123924761.9 | 58.99 | 0.00 | 0.00 |
April | 0.306756E+09 | -190393206.8 | 0.00 | 0.00 | 720.00 | 0.00 | -116362456.0 | 58.99 | 0.00 | 0.00 |
May | 0.312362E+09 | -193264037.9 | 0.00 | 0.00 | 744.00 | 0.00 | -119097696.9 | 58.99 | 0.00 | 0.00 |
June | 0.295129E+09 | -184608460.0 | 0.00 | 0.00 | 720.00 | 0.00 | -110520639.9 | 58.99 | 0.00 | 0.00 |
July | 0.292435E+09 | -179468707.0 | 0.00 | 0.00 | 744.00 | 0.00 | -112966331.2 | 59.00 | 0.00 | 0.00 |
August | 0.298503E+09 | -185826593.1 | 0.00 | 0.00 | 744.00 | 0.00 | -112675942.6 | 59.01 | 0.00 | 0.00 |
September | 0.286143E+09 | -176374094.9 | 0.00 | 0.00 | 720.00 | 0.00 | -109768895.9 | 58.99 | 0.00 | 0.00 |
October | 0.304407E+09 | -184292302.2 | 0.00 | 0.00 | 744.00 | 0.00 | -120115093.6 | 58.99 | 0.00 | 0.00 |
November | 0.303109E+09 | -183499549.6 | 0.00 | 0.00 | 720.00 | 0.00 | -119609465.6 | 58.99 | 0.00 | 0.00 |
December | 0.318632E+09 | -193685407.9 | 0.00 | 0.00 | 744.00 | 0.00 | -124946253.4 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.366479E+10 | -.225790E+10 | 8760.00 | -.140689E+10 | 58.99 | |||||
Minimum of Months | 0.286143E+09 | -206155611.7 | 0.00 | 0.00 | 672.00 | 0.00 | -124946253.4 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.330080E+09 | -176374094.9 | 0.00 | 0.00 | 744.00 | 0.00 | -109768895.9 | 59.01 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 195.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 217.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 215.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 359.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 417.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 410.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 429.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 396.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 337.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 234.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 171.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3515.67 | ||||||||||
Minimum of Months | 131.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 429.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.825976E+10 | 50934.82 | 04-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.669375E+10 | 50934.82 | 13-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.536547E+10 | 50934.82 | 04-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.506216E+09 | 13941.68 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.101594E+09 | 6649.16 | 05-MAY-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.399847E+09 | 6494.33 | 24-OCT-08:17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.411040E+10 | 50934.82 | 29-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.936329E+10 | 50934.82 | 09-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.348003E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.936329E+10 | 50934.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.224951E+10 | 24672.50 | 10-JAN-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.154884E+10 | 13881.81 | 17-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.114848E+10 | 5785.98 | 04-MAR-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 35968829.09 | 3557.05 | 01-APR-08:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6628784.62 | 782.04 | 28-OCT-08:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.835899E+09 | 8692.21 | 29-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.263370E+10 | 19203.96 | 30-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.845903E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.263370E+10 | 24672.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.329861E+10 | 22852.65 | 10-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.251103E+10 | 14827.61 | 17-FEB-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.200720E+10 | 8100.04 | 31-MAR-07:57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.150463E+09 | 4530.43 | 08-APR-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 4502749.78 | 1297.93 | 06-MAY-07:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.110807E+09 | 4179.20 | 28-OCT-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.159465E+10 | 8744.49 | 20-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.372238E+10 | 21870.22 | 31-DEC-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.133996E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.372238E+10 | 22852.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.358340E+10 | 27093.01 | 10-JAN-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.275457E+10 | 18745.39 | 20-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.226233E+10 | 15599.54 | 06-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.220195E+09 | 6806.22 | 01-APR-07:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 14887011.25 | 2537.84 | 06-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.205980E+09 | 4020.30 | 24-OCT-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.186280E+10 | 17354.77 | 20-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.399175E+10 | 27093.01 | 31-DEC-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.148959E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.399175E+10 | 27093.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.388903E+10 | 27207.50 | 02-JAN-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.301667E+10 | 23003.82 | 20-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.253924E+10 | 22352.56 | 06-MAR-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.304942E+09 | 8027.18 | 03-APR-07:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 45030242.73 | 3515.08 | 06-MAY-07:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.325544E+09 | 5681.97 | 23-OCT-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.212924E+10 | 23273.08 | 20-NOV-08:61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.429929E+10 | 27207.50 | 26-DEC-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.165490E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.429929E+10 | 27207.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.809866E+10 | 50056.32 | 01-JAN-10:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.637648E+10 | 50056.32 | 02-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.563120E+10 | 50056.32 | 04-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.856581E+09 | 23493.45 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.307952E+09 | 6684.17 | 06-MAY-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.108093E+10 | 21143.24 | 23-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.488960E+10 | 50056.32 | 20-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.879949E+10 | 50056.32 | 01-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.360409E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.879949E+10 | 50056.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.414785E+10 | 26582.35 | 01-JAN-10:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.325901E+10 | 26582.35 | 02-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.287081E+10 | 26582.35 | 04-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.439486E+09 | 12702.61 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.167035E+09 | 3323.55 | 05-MAY-08:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.547479E+09 | 11637.05 | 23-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.248238E+10 | 26582.35 | 20-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.451751E+10 | 26582.35 | 01-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.184316E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.451751E+10 | 26582.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.426343E+10 | 26404.62 | 01-JAN-10:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.336383E+10 | 26404.62 | 02-FEB-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.298303E+10 | 26404.62 | 03-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.492830E+09 | 14639.74 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.214244E+09 | 3120.55 | 06-MAY-08:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.607191E+09 | 13902.26 | 23-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.258161E+10 | 26404.62 | 20-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.462154E+10 | 26404.62 | 01-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.191277E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.462154E+10 | 26404.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.462273E+10 | 26078.35 | 01-JAN-10:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.369978E+10 | 26078.35 | 01-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.334715E+10 | 26078.35 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.653910E+09 | 22051.12 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.355439E+09 | 6350.31 | 17-MAY-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 925209.44 | 454.37 | 07-JUN-11:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.783126E+09 | 21336.25 | 23-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.289515E+10 | 26078.35 | 20-NOV-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.496858E+10 | 26078.35 | 01-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.213268E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.496858E+10 | 26078.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_HEATCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.577599E+10 | 25926.23 | 01-JAN-10:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.474072E+10 | 25926.23 | 01-FEB-09:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.442733E+10 | 25926.23 | 01-MAR-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.113050E+10 | 25926.23 | 01-APR-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.810252E+09 | 22175.39 | 17-MAY-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 26170570.58 | 1861.41 | 07-JUN-11:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130730E+10 | 25926.23 | 23-OCT-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.377985E+10 | 25926.23 | 03-NOV-08:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.616299E+10 | 25926.23 | 01-DEC-09:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.281611E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.616299E+10 | 25926.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_1:1_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.458726E+09 | 0.456909E+09 | 12290.97 | 30-APR-16:15 | 12290.97 | 0.00 |
May | 0.00 | 0.00 | 0.284700E+09 | 0.249497E+09 | 19341.70 | 23-MAY-08:62 | 14610.01 | 0.00 |
June | 0.00 | 0.00 | 0.185527E+10 | 0.157117E+10 | 28324.80 | 13-JUN-08:62 | 23920.03 | 0.00 |
July | 0.00 | 0.00 | 0.307410E+10 | 0.267543E+10 | 28482.36 | 18-JUL-08:62 | 19447.05 | 0.00 |
August | 0.00 | 0.00 | 0.295331E+10 | 0.248604E+10 | 28562.34 | 17-AUG-08:62 | 17107.87 | 0.00 |
September | 0.00 | 0.00 | 0.178412E+10 | 0.152522E+10 | 28284.62 | 11-SEP-08:62 | 19939.76 | 0.00 |
October | 0.00 | 0.00 | 2883034.34 | 2882095.54 | 1379.77 | 07-OCT-15:00 | 1379.77 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.104131E+11 | 0.896715E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.307410E+10 | 0.267543E+10 | 28562.34 | 23920.03 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_2:2_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 160322.48 | 148832.45 | 106.85 | 25-MAR-23:10 | 98.59 | 0.00 |
April | 0.00 | 0.00 | 0.309039E+09 | 0.305112E+09 | 15009.78 | 30-APR-19:02 | 15009.78 | 0.00 |
May | 0.00 | 0.00 | 0.223522E+09 | 0.198925E+09 | 15356.24 | 23-MAY-08:62 | 11649.71 | 0.00 |
June | 0.00 | 0.00 | 0.111055E+10 | 0.940067E+09 | 16549.11 | 25-JUN-18:00 | 9855.36 | 0.00 |
July | 0.00 | 0.00 | 0.182363E+10 | 0.157611E+10 | 15920.28 | 23-JUL-17:02 | 11687.71 | 0.00 |
August | 0.00 | 0.00 | 0.188942E+10 | 0.157961E+10 | 15821.39 | 17-AUG-08:62 | 9552.38 | 0.00 |
September | 0.00 | 0.00 | 0.109839E+10 | 0.939029E+09 | 15814.80 | 10-SEP-17:02 | 10712.79 | 0.00 |
October | 0.00 | 0.00 | 12846659.43 | 12444485.56 | 14680.22 | 01-OCT-18:47 | 14628.22 | 0.00 |
November | 0.00 | 0.00 | 269378.35 | 236651.43 | 237.05 | 08-NOV-23:10 | 200.34 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.646783E+10 | 0.555168E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.188942E+10 | 0.157961E+10 | 16549.11 | 15009.78 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_3:3_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.160063E+09 | 0.158457E+09 | 14673.41 | 30-APR-08:62 | 13409.57 | 0.00 |
May | 0.00 | 0.00 | 0.135134E+09 | 0.117538E+09 | 14816.49 | 23-MAY-07:02 | 10667.64 | 0.00 |
June | 0.00 | 0.00 | 0.891496E+09 | 0.761203E+09 | 15526.83 | 27-JUN-07:02 | 8705.09 | 0.00 |
July | 0.00 | 0.00 | 0.135146E+10 | 0.118011E+10 | 15528.86 | 18-JUL-07:02 | 10227.42 | 0.00 |
August | 0.00 | 0.00 | 0.146600E+10 | 0.123173E+10 | 15429.61 | 17-AUG-07:02 | 9177.83 | 0.00 |
September | 0.00 | 0.00 | 0.896244E+09 | 0.770774E+09 | 15239.94 | 16-SEP-07:02 | 9224.51 | 0.00 |
October | 0.00 | 0.00 | 2750707.98 | 2659930.75 | 6041.78 | 02-OCT-07:01 | 5113.69 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.490314E+10 | 0.422247E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.146600E+10 | 0.123173E+10 | 15528.86 | 13409.57 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_4:4_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.151746E+09 | 0.150522E+09 | 14606.03 | 30-APR-08:62 | 13337.94 | 0.00 |
May | 0.00 | 0.00 | 0.118779E+09 | 0.103717E+09 | 14384.41 | 24-MAY-07:01 | 10416.45 | 0.00 |
June | 0.00 | 0.00 | 0.870076E+09 | 0.742947E+09 | 15457.35 | 27-JUN-07:02 | 8660.25 | 0.00 |
July | 0.00 | 0.00 | 0.132942E+10 | 0.116096E+10 | 15458.90 | 18-JUL-07:02 | 10173.74 | 0.00 |
August | 0.00 | 0.00 | 0.143690E+10 | 0.120774E+10 | 15360.73 | 17-AUG-07:02 | 9131.86 | 0.00 |
September | 0.00 | 0.00 | 0.869465E+09 | 0.748425E+09 | 15170.72 | 16-SEP-07:02 | 9173.04 | 0.00 |
October | 0.00 | 0.00 | 1870217.27 | 1844973.39 | 1889.28 | 02-OCT-07:01 | 1596.39 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.477826E+10 | 0.411615E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.143690E+10 | 0.120774E+10 | 15458.90 | 13337.94 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_5:5_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.138542E+09 | 0.137622E+09 | 13110.07 | 30-APR-08:62 | 11951.13 | 0.00 |
May | 0.00 | 0.00 | 95745791.22 | 84463309.86 | 12256.51 | 01-MAY-07:01 | 10466.66 | 0.00 |
June | 0.00 | 0.00 | 0.822580E+09 | 0.703201E+09 | 15503.57 | 27-JUN-07:02 | 8661.84 | 0.00 |
July | 0.00 | 0.00 | 0.125276E+10 | 0.109747E+10 | 15504.18 | 18-JUL-07:02 | 10182.17 | 0.00 |
August | 0.00 | 0.00 | 0.133166E+10 | 0.112254E+10 | 15406.61 | 17-AUG-07:02 | 9133.77 | 0.00 |
September | 0.00 | 0.00 | 0.808291E+09 | 0.697321E+09 | 15214.84 | 16-SEP-07:02 | 9179.21 | 0.00 |
October | 0.00 | 0.00 | 1004491.57 | 1004403.27 | 611.60 | 07-OCT-15:00 | 611.60 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.445058E+10 | 0.384362E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.133166E+10 | 0.112254E+10 | 15504.18 | 11951.13 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_6:6_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.219669E+09 | 0.218524E+09 | 25165.17 | 30-APR-09:02 | 24468.75 | 0.00 |
May | 0.00 | 0.00 | 0.123260E+09 | 0.110791E+09 | 8875.67 | 22-MAY-15:00 | 8179.98 | 0.00 |
June | 0.00 | 0.00 | 0.137885E+10 | 0.117713E+10 | 28376.11 | 13-JUN-08:62 | 23036.84 | 0.00 |
July | 0.00 | 0.00 | 0.206353E+10 | 0.181081E+10 | 28371.00 | 18-JUL-08:62 | 19230.42 | 0.00 |
August | 0.00 | 0.00 | 0.218125E+10 | 0.184410E+10 | 28422.97 | 17-AUG-08:62 | 17066.89 | 0.00 |
September | 0.00 | 0.00 | 0.131704E+10 | 0.113785E+10 | 28010.18 | 16-SEP-08:62 | 17985.32 | 0.00 |
October | 0.00 | 0.00 | 1451786.79 | 1443479.23 | 888.14 | 07-OCT-15:00 | 888.14 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.728505E+10 | 0.630065E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.218125E+10 | 0.184410E+10 | 28422.97 | 24468.75 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_7:7_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.107075E+09 | 0.106601E+09 | 11070.74 | 30-APR-09:02 | 10763.41 | 0.00 |
May | 0.00 | 0.00 | 57856635.07 | 52420024.32 | 4555.31 | 22-MAY-15:00 | 4202.72 | 0.00 |
June | 0.00 | 0.00 | 0.692595E+09 | 0.593016E+09 | 15126.44 | 13-JUN-08:62 | 12274.22 | 0.00 |
July | 0.00 | 0.00 | 0.102465E+10 | 0.904276E+09 | 15123.60 | 18-JUL-08:62 | 10254.08 | 0.00 |
August | 0.00 | 0.00 | 0.106655E+10 | 0.906286E+09 | 15151.34 | 17-AUG-08:62 | 9100.23 | 0.00 |
September | 0.00 | 0.00 | 0.652547E+09 | 0.565796E+09 | 14931.79 | 16-SEP-08:62 | 9594.91 | 0.00 |
October | 0.00 | 0.00 | 310020.99 | 310007.09 | 337.35 | 07-OCT-15:00 | 337.35 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.360158E+10 | 0.312871E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.106655E+10 | 0.906286E+09 | 15151.34 | 12274.22 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_8:8_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.100651E+09 | 0.100244E+09 | 9450.06 | 30-APR-09:02 | 9176.71 | 0.00 |
May | 0.00 | 0.00 | 52863036.74 | 48060653.98 | 4405.89 | 22-MAY-15:00 | 4063.44 | 0.00 |
June | 0.00 | 0.00 | 0.665125E+09 | 0.569853E+09 | 15003.13 | 13-JUN-08:62 | 12154.33 | 0.00 |
July | 0.00 | 0.00 | 0.988565E+09 | 0.874027E+09 | 15000.86 | 18-JUL-08:62 | 10157.90 | 0.00 |
August | 0.00 | 0.00 | 0.102589E+10 | 0.872817E+09 | 15028.72 | 17-AUG-08:62 | 9014.80 | 0.00 |
September | 0.00 | 0.00 | 0.624792E+09 | 0.542332E+09 | 14811.12 | 16-SEP-08:62 | 9506.04 | 0.00 |
October | 0.00 | 0.00 | 134270.94 | 134270.94 | 205.07 | 07-OCT-15:00 | 205.07 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.345802E+10 | 0.300747E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.102589E+10 | 0.874027E+09 | 15028.72 | 12154.33 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_9:9_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 88005265.36 | 87733507.42 | 5279.74 | 30-APR-15:00 | 5279.74 | 0.00 |
May | 0.00 | 0.00 | 44199690.74 | 40424162.29 | 4093.37 | 22-MAY-15:00 | 3772.38 | 0.00 |
June | 0.00 | 0.00 | 0.605417E+09 | 0.519510E+09 | 14784.51 | 13-JUN-08:62 | 11925.04 | 0.00 |
July | 0.00 | 0.00 | 0.903130E+09 | 0.803205E+09 | 14782.76 | 18-JUL-08:62 | 9970.32 | 0.00 |
August | 0.00 | 0.00 | 0.922550E+09 | 0.788141E+09 | 14811.12 | 17-AUG-08:62 | 8847.43 | 0.00 |
September | 0.00 | 0.00 | 0.559285E+09 | 0.486896E+09 | 13602.58 | 16-SEP-08:62 | 8696.19 | 0.00 |
October | 0.00 | 0.00 | 11702.87 | 11702.87 | 7.24 | 05-OCT-15:00 | 7.24 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.312260E+10 | 0.272592E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.922550E+09 | 0.803205E+09 | 14811.12 | 11925.04 | 0.00 |
Report: CoilReportMonthly
For: PSZ-AC_10:10_UNITARY_PACKAGE_COOLCOIL
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 70290050.26 | 70191631.19 | 4820.25 | 30-APR-15:00 | 4820.25 | 0.00 |
May | 0.00 | 0.00 | 37214679.63 | 34104596.59 | 3694.71 | 22-MAY-15:00 | 3401.83 | 0.00 |
June | 0.00 | 0.00 | 0.534883E+09 | 0.460554E+09 | 13489.43 | 26-JUN-08:62 | 10815.08 | 0.00 |
July | 0.00 | 0.00 | 0.786939E+09 | 0.711374E+09 | 14758.62 | 22-JUL-08:61 | 13597.03 | 0.00 |
August | 0.00 | 0.00 | 0.749697E+09 | 0.646325E+09 | 11503.41 | 17-AUG-08:62 | 6814.56 | 0.00 |
September | 0.00 | 0.00 | 0.462830E+09 | 0.404400E+09 | 5460.48 | 13-SEP-14:10 | 4711.08 | 0.00 |
October | 0.00 | 0.00 | 4151.66 | 4151.66 | 0.94 | 07-OCT-13:00 | 0.94 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:05 | 0.00 | 0.00 |
Annual Sum or Average | 0.264186E+10 | 0.232695E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.786939E+09 | 0.711374E+09 | 14758.62 | 13597.03 | 0.00 |
Report: FanReportMonthly
For: PSZ-AC_1:1_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.329842E+10 | 0.60 | 1817.70 | 05-JAN-12:10 | 0.89 |
February | 0.298394E+10 | 0.60 | 1817.70 | 01-FEB-09:02 | 0.88 |
March | 0.330458E+10 | 0.60 | 1817.70 | 01-MAR-09:07 | 0.89 |
April | 0.319988E+10 | 0.60 | 1817.70 | 28-APR-20:04 | 0.88 |
May | 0.329804E+10 | 0.60 | 1817.70 | 26-MAY-15:30 | 0.88 |
June | 0.319988E+10 | 0.60 | 1817.70 | 08-JUN-17:10 | 0.88 |
July | 0.330458E+10 | 0.60 | 1817.70 | 03-JUL-17:20 | 0.88 |
August | 0.329804E+10 | 0.60 | 1817.70 | 31-AUG-20:04 | 0.88 |
September | 0.320643E+10 | 0.60 | 1817.70 | 06-SEP-18:10 | 0.88 |
October | 0.329804E+10 | 0.60 | 1817.70 | 27-OCT-18:20 | 0.88 |
November | 0.318679E+10 | 0.60 | 1817.70 | 01-NOV-11:50 | 0.88 |
December | 0.331122E+10 | 0.60 | 1817.70 | 01-DEC-18:40 | 0.89 |
Annual Sum or Average | 0.388898E+11 | 0.60 | |||
Minimum of Months | 0.298394E+10 | 0.60 | 1817.70 | 0.88 | |
Maximum of Months | 0.331122E+10 | 0.60 | 1817.70 | 0.89 |
Report: FanReportMonthly
For: PSZ-AC_2:2_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.141337E+10 | 0.48 | 1040.65 | 01-JAN-09:40 | 0.92 |
February | 0.127794E+10 | 0.48 | 1040.65 | 01-FEB-11:20 | 0.91 |
March | 0.143871E+10 | 0.50 | 1040.65 | 01-MAR-10:10 | 0.92 |
April | 0.149278E+10 | 0.60 | 1040.65 | 01-APR-08:07 | 0.92 |
May | 0.160571E+10 | 0.61 | 1040.65 | 11-MAY-11:00 | 0.92 |
June | 0.176883E+10 | 0.62 | 1040.65 | 01-JUN-09:30 | 0.91 |
July | 0.184184E+10 | 0.61 | 1040.65 | 01-JUL-08:62 | 0.91 |
August | 0.185577E+10 | 0.61 | 1040.65 | 01-AUG-11:20 | 0.91 |
September | 0.176934E+10 | 0.62 | 1040.65 | 01-SEP-13:10 | 0.91 |
October | 0.152892E+10 | 0.60 | 1040.65 | 01-OCT-14:30 | 0.91 |
November | 0.137701E+10 | 0.52 | 1040.65 | 01-NOV-11:40 | 0.92 |
December | 0.140488E+10 | 0.46 | 1040.65 | 01-DEC-11:00 | 0.92 |
Annual Sum or Average | 0.187751E+11 | 0.56 | |||
Minimum of Months | 0.127794E+10 | 0.46 | 1040.65 | 0.91 | |
Maximum of Months | 0.185577E+10 | 0.62 | 1040.65 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_3:3_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.148606E+10 | 0.50 | 1026.85 | 16-JAN-10:50 | 0.92 |
February | 0.134559E+10 | 0.50 | 1026.85 | 01-FEB-07:10 | 0.92 |
March | 0.151563E+10 | 0.51 | 1026.85 | 01-MAR-07:10 | 0.92 |
April | 0.144170E+10 | 0.50 | 1026.85 | 01-APR-06:10 | 0.92 |
May | 0.150085E+10 | 0.50 | 1026.85 | 01-MAY-06:01 | 0.92 |
June | 0.146388E+10 | 0.50 | 1026.85 | 18-JUN-11:40 | 0.91 |
July | 0.147867E+10 | 0.49 | 1026.85 | 02-JUL-15:30 | 0.91 |
August | 0.151563E+10 | 0.50 | 1026.85 | 08-AUG-18:20 | 0.91 |
September | 0.144170E+10 | 0.49 | 1026.85 | 16-SEP-08:62 | 0.91 |
October | 0.148606E+10 | 0.49 | 1026.85 | 04-OCT-15:00 | 0.91 |
November | 0.144170E+10 | 0.50 | 1026.85 | 01-NOV-06:01 | 0.92 |
December | 0.147867E+10 | 0.49 | 1026.85 | 01-DEC-07:10 | 0.92 |
Annual Sum or Average | 0.175961E+11 | 0.50 | |||
Minimum of Months | 0.134559E+10 | 0.49 | 1026.85 | 0.91 | |
Maximum of Months | 0.151563E+10 | 0.51 | 1026.85 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_4:4_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.147949E+10 | 0.50 | 1022.31 | 01-JAN-15:10 | 0.92 |
February | 0.133964E+10 | 0.50 | 1022.31 | 09-FEB-11:00 | 0.92 |
March | 0.150893E+10 | 0.51 | 1022.31 | 23-MAR-08:10 | 0.92 |
April | 0.143533E+10 | 0.50 | 1022.31 | 01-APR-08:05 | 0.92 |
May | 0.149421E+10 | 0.50 | 1022.31 | 04-MAY-16:40 | 0.91 |
June | 0.145741E+10 | 0.50 | 1022.31 | 01-JUN-12:50 | 0.91 |
July | 0.147213E+10 | 0.49 | 1022.31 | 01-JUL-16:20 | 0.91 |
August | 0.150893E+10 | 0.50 | 1022.31 | 01-AUG-10:30 | 0.91 |
September | 0.143533E+10 | 0.49 | 1022.31 | 01-SEP-15:30 | 0.91 |
October | 0.147949E+10 | 0.49 | 1022.31 | 28-OCT-14:20 | 0.91 |
November | 0.143533E+10 | 0.50 | 1022.31 | 01-NOV-08:20 | 0.92 |
December | 0.147213E+10 | 0.49 | 1022.31 | 01-DEC-10:10 | 0.92 |
Annual Sum or Average | 0.175183E+11 | 0.50 | |||
Minimum of Months | 0.133964E+10 | 0.49 | 1022.31 | 0.91 | |
Maximum of Months | 0.150893E+10 | 0.51 | 1022.31 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_5:5_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.148417E+10 | 0.50 | 1025.55 | 01-JAN-10:09 | 0.92 |
February | 0.134388E+10 | 0.50 | 1025.55 | 01-FEB-08:10 | 0.92 |
March | 0.151371E+10 | 0.51 | 1025.55 | 01-MAR-10:00 | 0.92 |
April | 0.143987E+10 | 0.50 | 1025.55 | 01-APR-07:30 | 0.92 |
May | 0.149894E+10 | 0.50 | 1025.55 | 24-MAY-16:40 | 0.91 |
June | 0.146202E+10 | 0.50 | 1025.55 | 01-JUN-13:00 | 0.91 |
July | 0.147679E+10 | 0.49 | 1025.55 | 09-JUL-11:40 | 0.91 |
August | 0.151371E+10 | 0.50 | 1025.55 | 01-AUG-07:03 | 0.91 |
September | 0.143987E+10 | 0.49 | 1025.55 | 01-SEP-08:62 | 0.91 |
October | 0.148417E+10 | 0.49 | 1025.55 | 05-OCT-10:20 | 0.92 |
November | 0.143987E+10 | 0.50 | 1025.55 | 01-NOV-07:06 | 0.92 |
December | 0.147679E+10 | 0.49 | 1025.55 | 01-DEC-08:20 | 0.92 |
Annual Sum or Average | 0.175738E+11 | 0.50 | |||
Minimum of Months | 0.134388E+10 | 0.49 | 1025.55 | 0.91 | |
Maximum of Months | 0.151371E+10 | 0.51 | 1025.55 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_6:6_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.241666E+10 | 0.44 | 1809.42 | 02-JAN-11:50 | 0.89 |
February | 0.218868E+10 | 0.44 | 1809.42 | 01-FEB-20:30 | 0.88 |
March | 0.246878E+10 | 0.45 | 1809.42 | 08-MAR-16:00 | 0.89 |
April | 0.234501E+10 | 0.44 | 1809.42 | 04-APR-11:50 | 0.89 |
May | 0.244272E+10 | 0.45 | 1809.42 | 04-MAY-13:30 | 0.88 |
June | 0.238409E+10 | 0.45 | 1809.42 | 01-JUN-12:20 | 0.88 |
July | 0.240364E+10 | 0.44 | 1809.42 | 01-JUL-08:62 | 0.88 |
August | 0.246878E+10 | 0.45 | 1809.42 | 01-AUG-12:00 | 0.88 |
September | 0.234501E+10 | 0.44 | 1809.42 | 01-SEP-17:20 | 0.88 |
October | 0.241666E+10 | 0.44 | 1809.42 | 03-OCT-15:20 | 0.88 |
November | 0.234501E+10 | 0.44 | 1809.42 | 06-NOV-17:00 | 0.88 |
December | 0.240364E+10 | 0.44 | 1809.42 | 28-DEC-11:00 | 0.89 |
Annual Sum or Average | 0.286287E+11 | 0.44 | |||
Minimum of Months | 0.218868E+10 | 0.44 | 1809.42 | 0.88 | |
Maximum of Months | 0.246878E+10 | 0.45 | 1809.42 | 0.89 |
Report: FanReportMonthly
For: PSZ-AC_7:7_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.133289E+10 | 0.46 | 997.97 | 05-JAN-14:50 | 0.92 |
February | 0.120715E+10 | 0.46 | 997.97 | 01-FEB-16:50 | 0.91 |
March | 0.136163E+10 | 0.47 | 997.97 | 06-MAR-15:40 | 0.91 |
April | 0.129337E+10 | 0.46 | 997.97 | 03-APR-09:50 | 0.92 |
May | 0.134726E+10 | 0.46 | 997.97 | 04-MAY-12:20 | 0.91 |
June | 0.131493E+10 | 0.46 | 997.97 | 08-JUN-17:10 | 0.92 |
July | 0.132571E+10 | 0.45 | 997.97 | 11-JUL-20:00 | 0.91 |
August | 0.136163E+10 | 0.46 | 997.97 | 02-AUG-15:10 | 0.91 |
September | 0.129337E+10 | 0.46 | 997.97 | 11-SEP-13:40 | 0.91 |
October | 0.133289E+10 | 0.46 | 997.97 | 06-OCT-15:50 | 0.92 |
November | 0.129337E+10 | 0.46 | 997.97 | 02-NOV-11:10 | 0.92 |
December | 0.132571E+10 | 0.45 | 997.97 | 02-DEC-17:10 | 0.91 |
Annual Sum or Average | 0.157899E+11 | 0.46 | |||
Minimum of Months | 0.120715E+10 | 0.45 | 997.97 | 0.91 | |
Maximum of Months | 0.136163E+10 | 0.47 | 997.97 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_8:8_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.132228E+10 | 0.46 | 990.03 | 02-JAN-09:05 | 0.92 |
February | 0.119754E+10 | 0.46 | 990.03 | 02-FEB-12:20 | 0.92 |
March | 0.135079E+10 | 0.47 | 990.03 | 01-MAR-11:00 | 0.92 |
April | 0.128308E+10 | 0.46 | 990.03 | 02-APR-11:50 | 0.92 |
May | 0.133654E+10 | 0.46 | 990.03 | 03-MAY-12:20 | 0.91 |
June | 0.130446E+10 | 0.46 | 990.03 | 02-JUN-18:00 | 0.91 |
July | 0.131515E+10 | 0.45 | 990.03 | 11-JUL-14:30 | 0.91 |
August | 0.135079E+10 | 0.46 | 990.03 | 01-AUG-18:10 | 0.91 |
September | 0.128308E+10 | 0.46 | 990.03 | 01-SEP-18:50 | 0.91 |
October | 0.132228E+10 | 0.46 | 990.03 | 05-OCT-15:50 | 0.92 |
November | 0.128308E+10 | 0.46 | 990.03 | 01-NOV-15:10 | 0.91 |
December | 0.131515E+10 | 0.45 | 990.03 | 02-DEC-18:10 | 0.91 |
Annual Sum or Average | 0.156642E+11 | 0.46 | |||
Minimum of Months | 0.119754E+10 | 0.45 | 990.03 | 0.91 | |
Maximum of Months | 0.135079E+10 | 0.47 | 990.03 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_9:9_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.130370E+10 | 0.46 | 976.12 | 05-JAN-16:20 | 0.92 |
February | 0.118071E+10 | 0.46 | 976.12 | 01-FEB-10:50 | 0.91 |
March | 0.133182E+10 | 0.47 | 976.12 | 04-MAR-12:10 | 0.92 |
April | 0.126505E+10 | 0.46 | 976.12 | 02-APR-14:10 | 0.92 |
May | 0.131776E+10 | 0.46 | 976.12 | 03-MAY-12:00 | 0.91 |
June | 0.128613E+10 | 0.46 | 976.12 | 08-JUN-17:50 | 0.92 |
July | 0.129668E+10 | 0.45 | 976.12 | 05-JUL-15:50 | 0.91 |
August | 0.133182E+10 | 0.46 | 976.12 | 01-AUG-16:50 | 0.91 |
September | 0.126505E+10 | 0.46 | 976.12 | 01-SEP-13:30 | 0.91 |
October | 0.130370E+10 | 0.46 | 976.12 | 09-OCT-16:30 | 0.91 |
November | 0.126505E+10 | 0.46 | 976.12 | 01-NOV-11:10 | 0.92 |
December | 0.129668E+10 | 0.45 | 976.12 | 04-DEC-11:10 | 0.92 |
Annual Sum or Average | 0.154442E+11 | 0.46 | |||
Minimum of Months | 0.118071E+10 | 0.45 | 976.12 | 0.91 | |
Maximum of Months | 0.133182E+10 | 0.47 | 976.12 | 0.92 |
Report: FanReportMonthly
For: PSZ-AC_10:10_ADDAQ_UNITARY_PACKAGE_FAN
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.130616E+10 | 0.46 | 977.96 | 01-JAN-10:15 | 0.92 |
February | 0.118294E+10 | 0.46 | 977.96 | 01-FEB-11:20 | 0.91 |
March | 0.133433E+10 | 0.47 | 977.96 | 01-MAR-10:30 | 0.92 |
April | 0.126743E+10 | 0.46 | 977.96 | 01-APR-13:50 | 0.92 |
May | 0.132024E+10 | 0.46 | 977.96 | 02-MAY-08:10 | 0.92 |
June | 0.128856E+10 | 0.46 | 977.96 | 05-JUN-11:20 | 0.91 |
July | 0.129912E+10 | 0.45 | 977.96 | 05-JUL-19:10 | 0.92 |
August | 0.133433E+10 | 0.46 | 977.96 | 01-AUG-12:00 | 0.91 |
September | 0.126743E+10 | 0.46 | 977.96 | 01-SEP-11:40 | 0.91 |
October | 0.130616E+10 | 0.46 | 977.96 | 03-OCT-08:20 | 0.92 |
November | 0.126743E+10 | 0.46 | 977.96 | 01-NOV-09:30 | 0.92 |
December | 0.129912E+10 | 0.45 | 977.96 | 01-DEC-16:30 | 0.92 |
Annual Sum or Average | 0.154733E+11 | 0.46 | |||
Minimum of Months | 0.118294E+10 | 0.45 | 977.96 | 0.91 | |
Maximum of Months | 0.133433E+10 | 0.47 | 977.96 | 0.92 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.40 | 1.09 |
February | 0.82 | 0.69 |
March | 0.14 | 0.90 |
April | 0.58 | 1.36 |
May | 1.06 | 1.50 |
June | 0.50 | 1.50 |
July | 0.92 | 1.50 |
August | 0.50 | 1.50 |
September | 0.58 | 1.50 |
October | 0.56 | 1.50 |
November | 0.00 | 0.00 |
December | 0.46 | 1.14 |
Annual Sum or Average | 6.51 | 1.32 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.06 | 1.50 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.44 | 5.60 |
February | 2.22 | 5.47 |
March | 3.17 | 4.83 |
April | 3.50 | 2.50 |
May | 2.14 | 2.21 |
June | 1.81 | 3.21 |
July | 2.01 | 5.30 |
August | 1.31 | 3.93 |
September | 0.71 | 2.18 |
October | 2.31 | 2.72 |
November | 3.53 | 3.76 |
December | 1.64 | 5.19 |
Annual Sum or Average | 26.77 | 3.95 |
Minimum of Months | 0.71 | 2.18 |
Maximum of Months | 3.53 | 5.60 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.08 | 0.75 |
April | 1.54 | 0.67 |
May | 1.64 | 0.71 |
June | 0.62 | 0.75 |
July | 0.73 | 0.75 |
August | 1.00 | 0.75 |
September | 0.83 | 0.75 |
October | 1.50 | 0.71 |
November | 0.08 | 0.75 |
December | 0.00 | 0.00 |
Annual Sum or Average | 8.03 | 0.72 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.64 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 1.29 | 0.65 |
May | 1.56 | 0.71 |
June | 1.04 | 0.75 |
July | 0.56 | 0.75 |
August | 1.17 | 0.75 |
September | 1.17 | 0.75 |
October | 1.17 | 0.70 |
November | 0.08 | 0.75 |
December | 0.00 | 0.00 |
Annual Sum or Average | 8.03 | 0.72 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.56 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.93 | 0.62 |
May | 1.36 | 0.70 |
June | 1.04 | 0.75 |
July | 0.64 | 0.75 |
August | 1.08 | 0.75 |
September | 1.00 | 0.75 |
October | 0.92 | 0.68 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 6.98 | 0.71 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.36 | 0.75 |
Report: ZoneTemperatureOscillationReportMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.46 | 2.10 |
May | 0.58 | 3.30 |
June | 0.76 | 3.30 |
July | 1.34 | 3.30 |
August | 1.00 | 3.30 |
September | 0.50 | 3.30 |
October | 0.25 | 2.20 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 4.89 | 3.13 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 1.34 | 3.30 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.38 | 0.92 |
May | 0.42 | 1.65 |
June | 0.32 | 1.65 |
July | 0.67 | 1.65 |
August | 0.33 | 1.65 |
September | 0.25 | 1.65 |
October | 0.25 | 1.10 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 2.62 | 1.49 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.67 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.12 | 1.65 |
May | 0.25 | 1.65 |
June | 0.71 | 1.65 |
July | 0.67 | 1.65 |
August | 0.50 | 1.65 |
September | 0.08 | 1.65 |
October | 0.08 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 2.42 | 1.59 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.71 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.12 | 1.65 |
May | 0.08 | 1.65 |
June | 0.51 | 1.65 |
July | 0.34 | 1.65 |
August | 0.33 | 1.65 |
September | 0.17 | 1.65 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 1.56 | 1.65 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.51 | 1.65 |
Report: ZoneTemperatureOscillationReportMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.56 | 0.00 |
February | 0.08 | 0.00 |
March | 0.00 | 0.00 |
April | 0.12 | 1.65 |
May | 0.08 | 1.65 |
June | 0.35 | 1.65 |
July | 0.09 | 1.65 |
August | 0.06 | 1.65 |
September | 0.08 | 1.65 |
October | 0.00 | 0.00 |
November | 0.08 | 0.00 |
December | 0.17 | 0.00 |
Annual Sum or Average | 1.67 | 0.77 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.56 | 1.65 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.329842E+10 | 0.103247E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.298394E+10 | 0.836718E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.330458E+10 | 0.670684E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.332088E+10 | 0.632770E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.337449E+10 | 0.126993E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.368058E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.411692E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.407765E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.367306E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.329884E+10 | 0.499809E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.318679E+10 | 0.513800E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.331122E+10 | 0.117041E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.416274E+11 | 0.435004E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.298394E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.411692E+10 | 0.117041E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.141337E+10 | 0.281189E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.127794E+10 | 0.193606E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.143876E+10 | 0.143560E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.157044E+10 | 44961036.36 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.166244E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.204512E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.229974E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.233002E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.204543E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.153237E+10 | 8285980.77 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.137709E+10 | 0.104487E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.140488E+10 | 0.329212E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.203976E+11 | 0.105738E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.127794E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.233002E+10 | 0.329212E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.148606E+10 | 0.412326E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.134559E+10 | 0.313878E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.151563E+10 | 0.250900E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.148280E+10 | 0.188078E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.153576E+10 | 5628437.22 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.168848E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.182566E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.189124E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.166942E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.148679E+10 | 0.138508E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.144170E+10 | 0.199332E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.147867E+10 | 0.465297E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.188478E+11 | 0.167495E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.134559E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.189124E+10 | 0.465297E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.147949E+10 | 0.447925E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.133964E+10 | 0.344321E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.150893E+10 | 0.282791E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.147436E+10 | 0.275243E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.152502E+10 | 18608764.06 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.167691E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.181357E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.187713E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.165651E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.147999E+10 | 0.257475E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.143533E+10 | 0.232850E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.147213E+10 | 0.498969E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.187390E+11 | 0.186199E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.133964E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.187713E+10 | 0.498969E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.148417E+10 | 0.486129E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.134388E+10 | 0.377084E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.151371E+10 | 0.317405E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.147564E+10 | 0.381178E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.152398E+10 | 56287803.41 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.167037E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.179939E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.185539E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.164606E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.148445E+10 | 0.406931E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.143987E+10 | 0.266155E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.147679E+10 | 0.537411E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.187137E+11 | 0.206862E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.134388E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.185539E+10 | 0.537411E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.241666E+10 | 0.101233E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.218868E+10 | 0.797060E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.246878E+10 | 0.703899E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.240355E+10 | 0.107073E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.247619E+10 | 0.384940E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.274549E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.295117E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.304537E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.269199E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.241707E+10 | 0.135116E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.234501E+10 | 0.611200E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.240364E+10 | 0.109994E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.305536E+11 | 0.450511E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.218868E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.304537E+10 | 0.109994E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.133289E+10 | 0.518482E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.120715E+10 | 0.407376E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.136163E+10 | 0.358852E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.132117E+10 | 0.549358E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.136255E+10 | 0.208794E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.149186E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.159077E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.163603E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.146080E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.133297E+10 | 0.684348E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.129337E+10 | 0.310298E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.132571E+10 | 0.564688E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.167169E+11 | 0.230395E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.120715E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.163603E+10 | 0.564688E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.132228E+10 | 0.532928E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.119754E+10 | 0.420479E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.135079E+10 | 0.372878E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.130925E+10 | 0.616038E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.135052E+10 | 0.267805E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.147469E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.157122E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.161502E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.144361E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.132232E+10 | 0.758989E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.128308E+10 | 0.322701E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.131515E+10 | 0.577693E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.165555E+11 | 0.239096E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.119754E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.161502E+10 | 0.577693E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.130370E+10 | 0.577841E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.118071E+10 | 0.462472E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.133182E+10 | 0.418393E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.128803E+10 | 0.817388E+09 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.132949E+10 | 0.444298E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.144183E+10 | 1156511.80 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.153142E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.157047E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.140935E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.130371E+10 | 0.978908E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.126505E+10 | 0.361893E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.129668E+10 | 0.621073E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.162523E+11 | 0.266585E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.118071E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.157047E+10 | 0.621073E+10 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.130616E+10 | 0.721998E+10 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.118294E+10 | 0.592590E+10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.133433E+10 | 0.553416E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.128589E+10 | 0.141313E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.133019E+10 | 0.101282E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.142723E+10 | 32713213.22 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.150450E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.153000E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.138773E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.130616E+10 | 0.163413E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.126743E+10 | 0.472481E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.129912E+10 | 0.770374E+10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.161617E+11 | 0.352014E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.118294E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.153000E+10 | 0.770374E+10 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.329842E+10 | 0.00 | 0.825976E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.298394E+10 | 0.00 | 0.669375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.330458E+10 | 0.00 | 0.536547E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.319988E+10 | 0.458726E+09 | 0.506216E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.329804E+10 | 0.284700E+09 | 0.101594E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.319988E+10 | 0.185527E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.330458E+10 | 0.307410E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.329804E+10 | 0.295331E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.320643E+10 | 0.178412E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.329804E+10 | 2883034.34 | 0.399847E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.318679E+10 | 0.00 | 0.411040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.331122E+10 | 0.00 | 0.936329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.388898E+11 | 0.104131E+11 | 0.348003E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.298394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.331122E+10 | 0.307410E+10 | 0.936329E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.141337E+10 | 0.00 | 0.224951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127794E+10 | 0.00 | 0.154884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143871E+10 | 160322.48 | 0.114848E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.149278E+10 | 0.309039E+09 | 35968829.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.160571E+10 | 0.223522E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.176883E+10 | 0.111055E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.184184E+10 | 0.182363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.185577E+10 | 0.188942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.176934E+10 | 0.109839E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152892E+10 | 12846659.43 | 6628784.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.137701E+10 | 269378.35 | 0.835899E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.140488E+10 | 0.00 | 0.263370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.187751E+11 | 0.646783E+10 | 0.845903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.127794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.185577E+10 | 0.188942E+10 | 0.263370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.148606E+10 | 0.00 | 0.329861E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134559E+10 | 0.00 | 0.251103E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.151563E+10 | 0.00 | 0.200720E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.144170E+10 | 0.160063E+09 | 0.150463E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150085E+10 | 0.135134E+09 | 4502749.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.146388E+10 | 0.891496E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147867E+10 | 0.135146E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151563E+10 | 0.146600E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.144170E+10 | 0.896244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148606E+10 | 2750707.98 | 0.110807E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144170E+10 | 0.00 | 0.159465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.147867E+10 | 0.00 | 0.372238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175961E+11 | 0.490314E+10 | 0.133996E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.134559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.151563E+10 | 0.146600E+10 | 0.372238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.147949E+10 | 0.00 | 0.358340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.133964E+10 | 0.00 | 0.275457E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.150893E+10 | 0.00 | 0.226233E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.143533E+10 | 0.151746E+09 | 0.220195E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.149421E+10 | 0.118779E+09 | 14887011.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145741E+10 | 0.870076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147213E+10 | 0.132942E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.150893E+10 | 0.143690E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.143533E+10 | 0.869465E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.147949E+10 | 1870217.27 | 0.205980E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.143533E+10 | 0.00 | 0.186280E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.147213E+10 | 0.00 | 0.399175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175183E+11 | 0.477826E+10 | 0.148959E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.133964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.150893E+10 | 0.143690E+10 | 0.399175E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.148417E+10 | 0.00 | 0.388903E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134388E+10 | 0.00 | 0.301667E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.151371E+10 | 0.00 | 0.253924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.143987E+10 | 0.138542E+09 | 0.304942E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.149894E+10 | 95745791.22 | 45030242.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.146202E+10 | 0.822580E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147679E+10 | 0.125276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151371E+10 | 0.133166E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.143987E+10 | 0.808291E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148417E+10 | 1004491.57 | 0.325544E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.143987E+10 | 0.00 | 0.212924E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.147679E+10 | 0.00 | 0.429929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175738E+11 | 0.445058E+10 | 0.165490E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.134388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.151371E+10 | 0.133166E+10 | 0.429929E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.241666E+10 | 0.00 | 0.809866E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.218868E+10 | 0.00 | 0.637648E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.246878E+10 | 0.00 | 0.563120E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.234501E+10 | 0.219669E+09 | 0.856581E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.244272E+10 | 0.123260E+09 | 0.307952E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.238409E+10 | 0.137885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.240364E+10 | 0.206353E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.246878E+10 | 0.218125E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.234501E+10 | 0.131704E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.241666E+10 | 1451786.79 | 0.108093E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.234501E+10 | 0.00 | 0.488960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.240364E+10 | 0.00 | 0.879949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.286287E+11 | 0.728505E+10 | 0.360409E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.218868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.246878E+10 | 0.218125E+10 | 0.879949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.133289E+10 | 0.00 | 0.414785E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.120715E+10 | 0.00 | 0.325901E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136163E+10 | 0.00 | 0.287081E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129337E+10 | 0.107075E+09 | 0.439486E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.134726E+10 | 57856635.07 | 0.167035E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.131493E+10 | 0.692595E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.132571E+10 | 0.102465E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.136163E+10 | 0.106655E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.129337E+10 | 0.652547E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133289E+10 | 310020.99 | 0.547479E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.129337E+10 | 0.00 | 0.248238E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132571E+10 | 0.00 | 0.451751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.157899E+11 | 0.360158E+10 | 0.184316E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.120715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.136163E+10 | 0.106655E+10 | 0.451751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.132228E+10 | 0.00 | 0.426343E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119754E+10 | 0.00 | 0.336383E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.135079E+10 | 0.00 | 0.298303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.128308E+10 | 0.100651E+09 | 0.492830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.133654E+10 | 52863036.74 | 0.214244E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.130446E+10 | 0.665125E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.131515E+10 | 0.988565E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.135079E+10 | 0.102589E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.128308E+10 | 0.624792E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.132228E+10 | 134270.94 | 0.607191E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128308E+10 | 0.00 | 0.258161E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.131515E+10 | 0.00 | 0.462154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.156642E+11 | 0.345802E+10 | 0.191277E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.119754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.135079E+10 | 0.102589E+10 | 0.462154E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.130370E+10 | 0.00 | 0.462273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118071E+10 | 0.00 | 0.369978E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133182E+10 | 0.00 | 0.334715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.126505E+10 | 88005265.36 | 0.653910E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.131776E+10 | 44199690.74 | 0.355439E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.128613E+10 | 0.605417E+09 | 925209.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.129668E+10 | 0.903130E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.133182E+10 | 0.922550E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.126505E+10 | 0.559285E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130370E+10 | 11702.87 | 0.783126E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126505E+10 | 0.00 | 0.289515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129668E+10 | 0.00 | 0.496858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.154442E+11 | 0.312260E+10 | 0.213268E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.118071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.133182E+10 | 0.922550E+09 | 0.496858E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.130616E+10 | 0.00 | 0.577599E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118294E+10 | 0.00 | 0.474072E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133433E+10 | 0.00 | 0.442733E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.126743E+10 | 70290050.26 | 0.113050E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.132024E+10 | 37214679.63 | 0.810252E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.128856E+10 | 0.534883E+09 | 26170570.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.129912E+10 | 0.786939E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.133433E+10 | 0.749697E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.126743E+10 | 0.462830E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130616E+10 | 4151.66 | 0.130730E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126743E+10 | 0.00 | 0.377985E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129912E+10 | 0.00 | 0.616299E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.154733E+11 | 0.264186E+10 | 0.281611E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.118294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.133433E+10 | 0.786939E+09 | 0.616299E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_1:1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.329842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103247E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.298394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.836718E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.330458E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.670684E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.319988E+10 | 0.00 | 0.00 | 0.00 | 0.121000E+09 | 0.00 | 0.632770E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.329804E+10 | 0.00 | 0.00 | 0.00 | 76449345.15 | 0.00 | 0.126993E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.319988E+10 | 0.00 | 0.00 | 0.00 | 0.480700E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.330458E+10 | 0.00 | 0.00 | 0.00 | 0.812339E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.329804E+10 | 0.00 | 0.00 | 0.00 | 0.779608E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.320643E+10 | 0.00 | 0.00 | 0.00 | 0.466632E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.329804E+10 | 0.00 | 0.00 | 0.00 | 804429.82 | 0.00 | 0.499809E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.318679E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.513800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.331122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117041E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.388898E+11 | 0.00 | 0.00 | 0.00 | 0.273753E+10 | 0.00 | 0.435004E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.298394E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.331122E+10 | 0.00 | 0.00 | 0.00 | 0.812339E+09 | 0.00 | 0.117041E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_2:2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.141337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.281189E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.127794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.193606E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.143871E+10 | 0.00 | 0.00 | 0.00 | 47457.84 | 0.00 | 0.143560E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.149278E+10 | 0.00 | 0.00 | 0.00 | 77655158.30 | 0.00 | 44961036.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.160571E+10 | 0.00 | 0.00 | 0.00 | 56730918.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.176883E+10 | 0.00 | 0.00 | 0.00 | 0.276288E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.184184E+10 | 0.00 | 0.00 | 0.00 | 0.457901E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.185577E+10 | 0.00 | 0.00 | 0.00 | 0.474251E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.176934E+10 | 0.00 | 0.00 | 0.00 | 0.276086E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.152892E+10 | 0.00 | 0.00 | 0.00 | 3451784.86 | 0.00 | 8285980.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.137701E+10 | 0.00 | 0.00 | 0.00 | 79644.76 | 0.00 | 0.104487E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.140488E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.329212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.187751E+11 | 0.00 | 0.00 | 0.00 | 0.162249E+10 | 0.00 | 0.105738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.127794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.185577E+10 | 0.00 | 0.00 | 0.00 | 0.474251E+09 | 0.00 | 0.329212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_3:3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.148606E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.412326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.313878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.151563E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250900E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.144170E+10 | 0.00 | 0.00 | 0.00 | 41105559.90 | 0.00 | 0.188078E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.150085E+10 | 0.00 | 0.00 | 0.00 | 34919396.81 | 0.00 | 5628437.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.146388E+10 | 0.00 | 0.00 | 0.00 | 0.224600E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147867E+10 | 0.00 | 0.00 | 0.00 | 0.346996E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151563E+10 | 0.00 | 0.00 | 0.00 | 0.375603E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.144170E+10 | 0.00 | 0.00 | 0.00 | 0.227717E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148606E+10 | 0.00 | 0.00 | 0.00 | 728215.96 | 0.00 | 0.138508E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.144170E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199332E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.147867E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.465297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175961E+11 | 0.00 | 0.00 | 0.00 | 0.125167E+10 | 0.00 | 0.167495E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.134559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.151563E+10 | 0.00 | 0.00 | 0.00 | 0.375603E+09 | 0.00 | 0.465297E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_4:4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.147949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.447925E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.133964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344321E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.150893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.282791E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.143533E+10 | 0.00 | 0.00 | 0.00 | 39033908.90 | 0.00 | 0.275243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.149421E+10 | 0.00 | 0.00 | 0.00 | 30811259.85 | 0.00 | 18608764.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.145741E+10 | 0.00 | 0.00 | 0.00 | 0.219503E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147213E+10 | 0.00 | 0.00 | 0.00 | 0.341438E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.150893E+10 | 0.00 | 0.00 | 0.00 | 0.368202E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.143533E+10 | 0.00 | 0.00 | 0.00 | 0.221185E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.147949E+10 | 0.00 | 0.00 | 0.00 | 505000.98 | 0.00 | 0.257475E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.143533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.232850E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.147213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.498969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175183E+11 | 0.00 | 0.00 | 0.00 | 0.122068E+10 | 0.00 | 0.186199E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.133964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.150893E+10 | 0.00 | 0.00 | 0.00 | 0.368202E+09 | 0.00 | 0.498969E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_5:5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.148417E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.486129E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.134388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.377084E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.151371E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.317405E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.143987E+10 | 0.00 | 0.00 | 0.00 | 35767289.24 | 0.00 | 0.381178E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.149894E+10 | 0.00 | 0.00 | 0.00 | 25036886.15 | 0.00 | 56287803.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.146202E+10 | 0.00 | 0.00 | 0.00 | 0.208351E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.147679E+10 | 0.00 | 0.00 | 0.00 | 0.322601E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.151371E+10 | 0.00 | 0.00 | 0.00 | 0.341679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.143987E+10 | 0.00 | 0.00 | 0.00 | 0.206190E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.148417E+10 | 0.00 | 0.00 | 0.00 | 272739.32 | 0.00 | 0.406931E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.143987E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266155E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.147679E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537411E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.175738E+11 | 0.00 | 0.00 | 0.00 | 0.113990E+10 | 0.00 | 0.206862E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.134388E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.151371E+10 | 0.00 | 0.00 | 0.00 | 0.341679E+09 | 0.00 | 0.537411E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_6:6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.241666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.101233E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.218868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.797060E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.246878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.703899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.234501E+10 | 0.00 | 0.00 | 0.00 | 58539413.79 | 0.00 | 0.107073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.244272E+10 | 0.00 | 0.00 | 0.00 | 33469407.87 | 0.00 | 0.384940E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.238409E+10 | 0.00 | 0.00 | 0.00 | 0.361392E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.240364E+10 | 0.00 | 0.00 | 0.00 | 0.547539E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.246878E+10 | 0.00 | 0.00 | 0.00 | 0.576596E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.234501E+10 | 0.00 | 0.00 | 0.00 | 0.346976E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.241666E+10 | 0.00 | 0.00 | 0.00 | 407685.67 | 0.00 | 0.135116E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.234501E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.611200E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.240364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109994E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.286287E+11 | 0.00 | 0.00 | 0.00 | 0.192492E+10 | 0.00 | 0.450511E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.218868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.246878E+10 | 0.00 | 0.00 | 0.00 | 0.576596E+09 | 0.00 | 0.109994E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_7:7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.133289E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.518482E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.120715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.407376E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.136163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.358852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.129337E+10 | 0.00 | 0.00 | 0.00 | 27795112.49 | 0.00 | 0.549358E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.134726E+10 | 0.00 | 0.00 | 0.00 | 15285250.35 | 0.00 | 0.208794E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.131493E+10 | 0.00 | 0.00 | 0.00 | 0.176938E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.132571E+10 | 0.00 | 0.00 | 0.00 | 0.265062E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.136163E+10 | 0.00 | 0.00 | 0.00 | 0.274399E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.129337E+10 | 0.00 | 0.00 | 0.00 | 0.167432E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.133289E+10 | 0.00 | 0.00 | 0.00 | 84499.42 | 0.00 | 0.684348E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.129337E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.310298E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132571E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.564688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.157899E+11 | 0.00 | 0.00 | 0.00 | 0.926996E+09 | 0.00 | 0.230395E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.120715E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.136163E+10 | 0.00 | 0.00 | 0.00 | 0.274399E+09 | 0.00 | 0.564688E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_8:8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.132228E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.532928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.119754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.420479E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.135079E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.372878E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.128308E+10 | 0.00 | 0.00 | 0.00 | 26172057.42 | 0.00 | 0.616038E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.133654E+10 | 0.00 | 0.00 | 0.00 | 13984239.33 | 0.00 | 0.267805E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.130446E+10 | 0.00 | 0.00 | 0.00 | 0.170233E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.131515E+10 | 0.00 | 0.00 | 0.00 | 0.256063E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.135079E+10 | 0.00 | 0.00 | 0.00 | 0.264228E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.128308E+10 | 0.00 | 0.00 | 0.00 | 0.160532E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.132228E+10 | 0.00 | 0.00 | 0.00 | 36647.15 | 0.00 | 0.758989E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128308E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.322701E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.131515E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.156642E+11 | 0.00 | 0.00 | 0.00 | 0.891248E+09 | 0.00 | 0.239096E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.119754E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.135079E+10 | 0.00 | 0.00 | 0.00 | 0.264228E+09 | 0.00 | 0.577693E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_9:9
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.130370E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.577841E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.462472E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.418393E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.126505E+10 | 0.00 | 0.00 | 0.00 | 22980282.95 | 0.00 | 0.817388E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.131776E+10 | 0.00 | 0.00 | 0.00 | 11730202.46 | 0.00 | 0.444298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.128613E+10 | 0.00 | 0.00 | 0.00 | 0.155696E+09 | 0.00 | 1156511.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.129668E+10 | 0.00 | 0.00 | 0.00 | 0.234744E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.133182E+10 | 0.00 | 0.00 | 0.00 | 0.238651E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.126505E+10 | 0.00 | 0.00 | 0.00 | 0.144298E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130370E+10 | 0.00 | 0.00 | 0.00 | 3208.84 | 0.00 | 0.978908E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126505E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.361893E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.621073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.154442E+11 | 0.00 | 0.00 | 0.00 | 0.808103E+09 | 0.00 | 0.266585E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.118071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.133182E+10 | 0.00 | 0.00 | 0.00 | 0.238651E+09 | 0.00 | 0.621073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-AC_10:10
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.130616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.721998E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.592590E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133433E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.553416E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.126743E+10 | 0.00 | 0.00 | 0.00 | 18458295.60 | 0.00 | 0.141313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.132024E+10 | 0.00 | 0.00 | 0.00 | 9946314.40 | 0.00 | 0.101282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.128856E+10 | 0.00 | 0.00 | 0.00 | 0.138675E+09 | 0.00 | 32713213.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.129912E+10 | 0.00 | 0.00 | 0.00 | 0.205377E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.133433E+10 | 0.00 | 0.00 | 0.00 | 0.195674E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.126743E+10 | 0.00 | 0.00 | 0.00 | 0.120293E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.130616E+10 | 0.00 | 0.00 | 0.00 | 1138.61 | 0.00 | 0.163413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.126743E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.472481E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.129912E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.770374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.154733E+11 | 0.00 | 0.00 | 0.00 | 0.688425E+09 | 0.00 | 0.352014E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.118294E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.133433E+10 | 0.00 | 0.00 | 0.00 | 0.205377E+09 | 0.00 | 0.770374E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.102422E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.401240E+10 | 0.00 | 0.00 | 0.52 |
February | 0.101896E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.243251E+10 | 0.00 | 0.00 | 0.53 |
March | 0.105138E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.198398E+10 | 0.00 | 0.00 | 0.53 |
April | 0.826685E+10 | 295776.72 | 0.00 | 4152521.05 | 507145.03 | 69940344.50 | 0.249752E+10 | 0.00 | 0.62 |
May | 0.764168E+10 | 522520.89 | 0.00 | 4581162.86 | 0.00 | 6120417.53 | 0.345691E+10 | 0.00 | 0.63 |
June | 0.137021E+10 | 86000517.94 | 0.00 | 13934578.76 | 996236.50 | 0.00 | 0.946535E+10 | 0.00 | 0.82 |
July | 0.335359E+09 | 0.113662E+09 | 0.00 | 21063744.44 | 673059.95 | 0.00 | 0.113898E+11 | 0.00 | 1.04 |
August | 85167204.75 | 2686266.34 | 0.00 | 22499766.22 | 0.00 | 0.00 | 0.119613E+11 | 0.00 | 1.21 |
September | 0.620561E+09 | 0.00 | 0.00 | 17657267.77 | 0.00 | 0.00 | 0.109036E+11 | 0.00 | 0.95 |
October | 0.802753E+10 | 0.00 | 0.00 | 2625414.41 | 0.00 | 20348994.46 | 0.285172E+10 | 0.00 | 0.56 |
November | 0.105783E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.116326E+10 | 0.00 | 0.00 | 0.52 |
December | 0.919914E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.517950E+10 | 0.00 | 0.00 | 0.53 |
Annual Sum or Average | 0.770704E+11 | 0.203167E+09 | 0.00 | 86514455.50 | 2176441.48 | 0.148681E+11 | 0.525263E+11 | 0.00 | 0.71 |
Minimum of Months | 85167204.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.52 |
Maximum of Months | 0.105783E+11 | 0.113662E+09 | 0.00 | 22499766.22 | 996236.50 | 0.517950E+10 | 0.119613E+11 | 0.00 | 1.21 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE1
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.400564E+10 | 0.00 | 0.00 | 16462.27 | 0.00 | 0.115305E+10 | 13158464.52 | 0.00 | 0.38 |
February | 0.413500E+10 | 0.00 | 0.00 | 6837.96 | 0.00 | 0.335905E+09 | 5335285.81 | 0.00 | 0.39 |
March | 0.431659E+10 | 0.00 | 0.00 | 58588.74 | 0.00 | 0.248174E+09 | 47973690.61 | 0.00 | 0.39 |
April | 0.249052E+10 | 233502.12 | 0.00 | 3522678.12 | 150846.85 | 388748.19 | 0.242528E+10 | 0.00 | 0.57 |
May | 0.234497E+10 | 358864.92 | 0.00 | 4008597.80 | 0.00 | 0.00 | 0.302963E+10 | 0.00 | 0.61 |
June | 0.216344E+09 | 45299735.52 | 0.00 | 9123313.41 | 407684.11 | 0.00 | 0.590497E+10 | 0.00 | 0.93 |
July | 44532406.29 | 53141513.33 | 0.00 | 11581577.50 | 327462.38 | 0.00 | 0.651128E+10 | 0.00 | 1.16 |
August | 27228164.46 | 1682622.61 | 0.00 | 12495985.68 | 0.00 | 0.00 | 0.666846E+10 | 0.00 | 1.35 |
September | 0.126911E+09 | 0.00 | 0.00 | 10675792.29 | 0.00 | 0.00 | 0.636840E+10 | 0.00 | 1.07 |
October | 0.254796E+10 | 0.00 | 0.00 | 2965761.86 | 0.00 | 0.00 | 0.242242E+10 | 0.00 | 0.51 |
November | 0.400276E+10 | 0.00 | 0.00 | 95098.50 | 0.00 | 0.285643E+09 | 72148050.91 | 0.00 | 0.39 |
December | 0.358728E+10 | 0.00 | 0.00 | 88.41 | 0.00 | 0.150433E+10 | 66694.01 | 0.00 | 0.38 |
Annual Sum or Average | 0.278457E+11 | 0.100716E+09 | 0.00 | 54550782.56 | 885993.34 | 0.352749E+10 | 0.334691E+11 | 0.00 | 0.68 |
Minimum of Months | 27228164.46 | 0.00 | 0.00 | 88.41 | 0.00 | 0.00 | 66694.01 | 0.00 | 0.38 |
Maximum of Months | 0.431659E+10 | 53141513.33 | 0.00 | 12495985.68 | 407684.11 | 0.150433E+10 | 0.666846E+10 | 0.00 | 1.35 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.345589E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.195705E+10 | 0.00 | 0.00 | 0.41 |
February | 0.353660E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117807E+10 | 0.00 | 0.00 | 0.41 |
March | 0.401616E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.790182E+09 | 0.00 | 0.00 | 0.42 |
April | 0.306033E+10 | 0.00 | 0.00 | 1386869.72 | 424459.58 | 17511856.63 | 0.104227E+10 | 0.00 | 0.50 |
May | 0.292455E+10 | 369921.29 | 0.00 | 1659651.53 | 0.00 | 0.00 | 0.136046E+10 | 0.00 | 0.52 |
June | 0.668751E+09 | 26870021.83 | 0.00 | 5458697.61 | 52275.39 | 0.00 | 0.353267E+10 | 0.00 | 0.71 |
July | 0.341379E+09 | 44570952.21 | 0.00 | 7281973.25 | 2115405.46 | 0.00 | 0.412021E+10 | 0.00 | 0.88 |
August | 0.284143E+09 | 1721722.47 | 0.00 | 8342166.49 | 0.00 | 0.00 | 0.442104E+10 | 0.00 | 1.07 |
September | 0.590042E+09 | 0.00 | 0.00 | 6434021.50 | 0.00 | 0.00 | 0.384386E+10 | 0.00 | 0.83 |
October | 0.305343E+10 | 0.00 | 0.00 | 1225403.80 | 0.00 | 9019435.39 | 0.110482E+10 | 0.00 | 0.45 |
November | 0.388666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576995E+09 | 0.00 | 0.00 | 0.41 |
December | 0.284916E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.252943E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.286671E+11 | 73532617.80 | 0.00 | 31788783.91 | 2592140.42 | 0.705826E+10 | 0.194253E+11 | 0.00 | 0.59 |
Minimum of Months | 0.284143E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.401616E+10 | 44570952.21 | 0.00 | 8342166.49 | 2115405.46 | 0.252943E+10 | 0.442104E+10 | 0.00 | 1.07 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE3
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.319480E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221452E+10 | 0.00 | 0.00 | 0.41 |
February | 0.325587E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.145753E+10 | 0.00 | 0.00 | 0.41 |
March | 0.362953E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117000E+10 | 0.00 | 0.00 | 0.42 |
April | 0.311156E+10 | 0.00 | 0.00 | 1193447.98 | 449115.94 | 47206984.07 | 0.877544E+09 | 0.00 | 0.50 |
May | 0.302300E+10 | 297971.70 | 0.00 | 1452657.63 | 0.00 | 0.00 | 0.117148E+10 | 0.00 | 0.51 |
June | 0.717534E+09 | 26555969.31 | 0.00 | 5148838.90 | 49932.12 | 0.00 | 0.340251E+10 | 0.00 | 0.70 |
July | 0.354274E+09 | 44529693.91 | 0.00 | 7078483.34 | 2102514.16 | 0.00 | 0.405301E+10 | 0.00 | 0.87 |
August | 0.284120E+09 | 1682572.06 | 0.00 | 8195219.66 | 0.00 | 0.00 | 0.438431E+10 | 0.00 | 1.06 |
September | 0.607363E+09 | 0.00 | 0.00 | 6208642.19 | 0.00 | 0.00 | 0.375885E+10 | 0.00 | 0.82 |
October | 0.307681E+10 | 0.00 | 0.00 | 1068184.11 | 0.00 | 15893044.91 | 0.992331E+09 | 0.00 | 0.45 |
November | 0.352909E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.922698E+09 | 0.00 | 0.00 | 0.41 |
December | 0.254189E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.283596E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.273258E+11 | 73066206.98 | 0.00 | 30345473.80 | 2601562.22 | 0.866380E+10 | 0.186400E+11 | 0.00 | 0.58 |
Minimum of Months | 0.284120E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.362953E+10 | 44529693.91 | 0.00 | 8195219.66 | 2102514.16 | 0.283596E+10 | 0.438431E+10 | 0.00 | 1.06 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE4
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.291800E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.248987E+10 | 0.00 | 0.00 | 0.41 |
February | 0.289947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.181341E+10 | 0.00 | 0.00 | 0.41 |
March | 0.324415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155153E+10 | 0.00 | 0.00 | 0.42 |
April | 0.310958E+10 | 0.00 | 0.00 | 987891.43 | 536751.93 | 0.110632E+09 | 0.713099E+09 | 0.00 | 0.49 |
May | 0.307954E+10 | 219030.03 | 0.00 | 1221680.00 | 0.00 | 6160869.10 | 0.997592E+09 | 0.00 | 0.50 |
June | 0.856490E+09 | 25833641.35 | 0.00 | 4521487.09 | 46577.01 | 0.00 | 0.311372E+10 | 0.00 | 0.68 |
July | 0.418719E+09 | 44044770.00 | 0.00 | 6547782.84 | 2250654.91 | 0.00 | 0.388158E+10 | 0.00 | 0.86 |
August | 0.294704E+09 | 1574919.95 | 0.00 | 7711471.21 | 0.00 | 0.00 | 0.429382E+10 | 0.00 | 1.05 |
September | 0.647106E+09 | 0.00 | 0.00 | 5744673.56 | 0.00 | 0.00 | 0.359750E+10 | 0.00 | 0.80 |
October | 0.306071E+10 | 0.00 | 0.00 | 880851.50 | 0.00 | 54633746.73 | 0.876084E+09 | 0.00 | 0.44 |
November | 0.326509E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.117955E+10 | 0.00 | 0.00 | 0.41 |
December | 0.221819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.315937E+10 | 0.00 | 0.00 | 0.41 |
Annual Sum or Average | 0.260117E+11 | 71672361.33 | 0.00 | 27615837.63 | 2833983.85 | 0.103652E+11 | 0.174734E+11 | 0.00 | 0.58 |
Minimum of Months | 0.294704E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.41 |
Maximum of Months | 0.326509E+10 | 44044770.00 | 0.00 | 7711471.21 | 2250654.91 | 0.315937E+10 | 0.429382E+10 | 0.00 | 1.05 |
Report: MechanicalVentilationLoadsMonthly
For: LGSTORE2
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.460112E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.537942E+10 | 0.00 | 0.00 | 0.38 |
February | 0.454011E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.415706E+10 | 0.00 | 0.00 | 0.38 |
March | 0.529842E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356897E+10 | 0.00 | 0.00 | 0.39 |
April | 0.571766E+10 | 0.00 | 0.00 | 1298535.50 | 865048.06 | 0.258533E+09 | 0.979083E+09 | 0.00 | 0.43 |
May | 0.562672E+10 | 0.00 | 0.00 | 1730364.32 | 0.00 | 11296884.80 | 0.158023E+10 | 0.00 | 0.44 |
June | 0.184880E+10 | 38176590.37 | 0.00 | 6419343.10 | 0.00 | 0.00 | 0.485804E+10 | 0.00 | 0.57 |
July | 0.672530E+09 | 69108995.10 | 0.00 | 10352497.10 | 3749206.04 | 0.00 | 0.665351E+10 | 0.00 | 0.72 |
August | 0.187033E+09 | 768498.51 | 0.00 | 12787305.30 | 11103.23 | 0.00 | 0.768639E+10 | 0.00 | 0.89 |
September | 0.831364E+09 | 0.00 | 0.00 | 8837656.02 | 0.00 | 0.00 | 0.628780E+10 | 0.00 | 0.67 |
October | 0.563828E+10 | 0.00 | 0.00 | 991753.66 | 0.00 | 0.158076E+09 | 0.124937E+10 | 0.00 | 0.39 |
November | 0.528123E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291643E+10 | 0.00 | 0.00 | 0.38 |
December | 0.327073E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.664788E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.435140E+11 | 0.108054E+09 | 0.00 | 42417455.00 | 4625357.34 | 0.230977E+11 | 0.292944E+11 | 0.00 | 0.50 |
Minimum of Months | 0.187033E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.571766E+10 | 69108995.10 | 0.00 | 12787305.30 | 3749206.04 | 0.664788E+10 | 0.768639E+10 | 0.00 | 0.89 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE5
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.207313E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.291217E+10 | 0.00 | 0.00 | 0.38 |
February | 0.197326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.237111E+10 | 0.00 | 0.00 | 0.38 |
March | 0.240208E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.202643E+10 | 0.00 | 0.00 | 0.39 |
April | 0.281563E+10 | 0.00 | 0.00 | 619259.52 | 467380.53 | 0.173576E+09 | 0.479509E+09 | 0.00 | 0.44 |
May | 0.281414E+10 | 0.00 | 0.00 | 825192.06 | 0.00 | 7572722.84 | 0.780364E+09 | 0.00 | 0.44 |
June | 0.101607E+10 | 19191001.10 | 0.00 | 3086428.29 | 0.00 | 0.00 | 0.236300E+10 | 0.00 | 0.58 |
July | 0.355172E+09 | 35002406.25 | 0.00 | 5103567.03 | 1896838.87 | 0.00 | 0.340873E+10 | 0.00 | 0.75 |
August | 95953855.47 | 400912.01 | 0.00 | 6393933.99 | 10906.27 | 0.00 | 0.399914E+10 | 0.00 | 0.93 |
September | 0.409487E+09 | 0.00 | 0.00 | 4404133.93 | 0.00 | 0.00 | 0.323539E+10 | 0.00 | 0.69 |
October | 0.277023E+10 | 0.00 | 0.00 | 456109.91 | 0.00 | 0.138595E+09 | 0.606037E+09 | 0.00 | 0.39 |
November | 0.245316E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.164067E+10 | 0.00 | 0.00 | 0.38 |
December | 0.150691E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.344786E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.206852E+11 | 54594319.36 | 0.00 | 20888624.73 | 2375125.67 | 0.127180E+11 | 0.148722E+11 | 0.00 | 0.51 |
Minimum of Months | 95953855.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.281563E+10 | 35002406.25 | 0.00 | 6393933.99 | 1896838.87 | 0.344786E+10 | 0.399914E+10 | 0.00 | 0.93 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE6
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.192741E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.305772E+10 | 0.00 | 0.00 | 0.38 |
February | 0.185559E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.248853E+10 | 0.00 | 0.00 | 0.38 |
March | 0.227555E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215250E+10 | 0.00 | 0.00 | 0.39 |
April | 0.279189E+10 | 0.00 | 0.00 | 562902.26 | 515956.54 | 0.196226E+09 | 0.442239E+09 | 0.00 | 0.43 |
May | 0.281244E+10 | 0.00 | 0.00 | 741267.13 | 0.00 | 12230196.25 | 0.725388E+09 | 0.00 | 0.44 |
June | 0.114464E+10 | 18691837.99 | 0.00 | 2776244.51 | 0.00 | 0.00 | 0.214513E+10 | 0.00 | 0.57 |
July | 0.380887E+09 | 34815633.17 | 0.00 | 4850772.11 | 1915693.99 | 0.00 | 0.330047E+10 | 0.00 | 0.73 |
August | 98726396.71 | 368285.88 | 0.00 | 6178526.28 | 14638.71 | 0.00 | 0.392629E+10 | 0.00 | 0.91 |
September | 0.450049E+09 | 0.00 | 0.00 | 4159930.36 | 0.00 | 0.00 | 0.311520E+10 | 0.00 | 0.68 |
October | 0.275751E+10 | 0.00 | 0.00 | 335272.51 | 0.00 | 0.214806E+09 | 0.504985E+09 | 0.00 | 0.39 |
November | 0.239668E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169615E+10 | 0.00 | 0.00 | 0.38 |
December | 0.144199E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.351244E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.203334E+11 | 53875757.03 | 0.00 | 19604915.17 | 2446289.24 | 0.133306E+11 | 0.141597E+11 | 0.00 | 0.51 |
Minimum of Months | 98726396.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.281244E+10 | 34815633.17 | 0.00 | 6178526.28 | 1915693.99 | 0.351244E+10 | 0.392629E+10 | 0.00 | 0.91 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE7
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.137582E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.360852E+10 | 0.00 | 0.00 | 0.38 |
February | 0.155781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278565E+10 | 0.00 | 0.00 | 0.38 |
March | 0.191766E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.250941E+10 | 0.00 | 0.00 | 0.39 |
April | 0.269594E+10 | 0.00 | 0.00 | 466169.89 | 631027.72 | 0.287569E+09 | 0.373779E+09 | 0.00 | 0.42 |
May | 0.278827E+10 | 0.00 | 0.00 | 557670.23 | 0.00 | 59559830.35 | 0.593767E+09 | 0.00 | 0.43 |
June | 0.141894E+10 | 17640107.07 | 0.00 | 2088280.03 | 0.00 | 0.00 | 0.167985E+10 | 0.00 | 0.54 |
July | 0.507668E+09 | 34348734.30 | 0.00 | 4200404.38 | 1932417.37 | 0.00 | 0.298333E+10 | 0.00 | 0.70 |
August | 0.144873E+09 | 301700.84 | 0.00 | 5582517.15 | 37734.91 | 0.00 | 0.370338E+10 | 0.00 | 0.88 |
September | 0.636194E+09 | 0.00 | 0.00 | 3495629.63 | 0.00 | 0.00 | 0.273475E+10 | 0.00 | 0.65 |
October | 0.272094E+10 | 0.00 | 0.00 | 140694.02 | 0.00 | 0.461968E+09 | 0.223588E+09 | 0.00 | 0.39 |
November | 0.200212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.208886E+10 | 0.00 | 0.00 | 0.38 |
December | 0.104102E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.391261E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.188073E+11 | 52290542.21 | 0.00 | 16531365.32 | 2601180.00 | 0.157141E+11 | 0.122924E+11 | 0.00 | 0.49 |
Minimum of Months | 0.144873E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.278827E+10 | 34348734.30 | 0.00 | 5582517.15 | 1932417.37 | 0.391261E+10 | 0.370338E+10 | 0.00 | 0.88 |
Report: MechanicalVentilationLoadsMonthly
For: SMSTORE8
Timestamp: 2020-06-03 19:19:03
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.442653E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.453513E+10 | 0.00 | 0.00 | 0.38 |
February | 0.375927E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.395610E+10 | 0.00 | 0.00 | 0.38 |
March | 0.793338E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362180E+10 | 0.00 | 0.00 | 0.39 |
April | 0.233275E+10 | 0.00 | 0.00 | 352504.34 | 860985.15 | 0.627796E+09 | 0.302382E+09 | 0.00 | 0.42 |
May | 0.250429E+10 | 0.00 | 0.00 | 298852.61 | 0.00 | 0.444329E+09 | 0.336813E+09 | 0.00 | 0.41 |
June | 0.189633E+10 | 16482191.92 | 0.00 | 1248624.81 | 128683.48 | 727654.15 | 0.918376E+09 | 0.00 | 0.51 |
July | 0.716973E+09 | 34601849.89 | 0.00 | 3066799.91 | 2057016.82 | 0.00 | 0.241025E+10 | 0.00 | 0.64 |
August | 0.256718E+09 | 240458.04 | 0.00 | 4367616.79 | 0.00 | 0.00 | 0.322631E+10 | 0.00 | 0.81 |
September | 0.109956E+10 | 0.00 | 0.00 | 2410743.78 | 0.00 | 0.00 | 0.193944E+10 | 0.00 | 0.60 |
October | 0.231853E+10 | 0.00 | 0.00 | 46561.46 | 0.00 | 0.906543E+09 | 73090932.90 | 0.00 | 0.38 |
November | 0.105884E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.301224E+10 | 0.00 | 0.00 | 0.38 |
December | 0.130430E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.480411E+10 | 0.00 | 0.00 | 0.38 |
Annual Sum or Average | 0.139263E+11 | 51324499.85 | 0.00 | 11791703.69 | 3046685.44 | 0.219088E+11 | 0.920666E+10 | 0.00 | 0.47 |
Minimum of Months | 0.130430E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.38 |
Maximum of Months | 0.250429E+10 | 34601849.89 | 0.00 | 4367616.79 | 2057016.82 | 0.480411E+10 | 0.322631E+10 | 0.00 | 0.81 |