Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470
Simulation Timestamp: 2020-06-03 19:11:35
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 2598.53 | 537.43 | 537.43 |
Net Site Energy | 2598.53 | 537.43 | 537.43 |
Total Source Energy | 4494.07 | 929.46 | 929.46 |
Net Source Energy | 4494.07 | 929.46 | 929.46 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 1793.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 9.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 476.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 98.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 53.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 27.51 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 805.22 | 1793.32 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 1793.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 9.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 476.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 98.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 53.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 27.51 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 118.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 18.79 | 370.89 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 166.53 | 370.89 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 118.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 18.79 | 370.89 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 166.53 | 370.89 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 805.215 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 805.215 | 100.00 |
Total On-Site and Utility Electric Sources | 805.215 | 100.00 |
Total Electricity End Uses | 805.215 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 119.50 |
Time Setpoint Not Met During Occupied Cooling | 2.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2211.00 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
| Meter |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| ELECTRIC TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATERHEATINGCOIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATERFAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Latitude [deg] | 48.57 |
Longitude [deg] | -93.4 |
Elevation [m] | 359.00 |
Time Zone | -6.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 14.86 |
Skylight-Roof Ratio [%] | 0.32 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 10.6337 | 47.38 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 8.5069 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 8.5069 | 2.5587 | |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.6111 | 967.03 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.6111 | 967.03 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 30-JUN-14:00 | 03-JAN-17:10 | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 355658.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 14645.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5516.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1812.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 67276.17 | 355658.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 355658.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 14645.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 3210.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1812.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 1943.96 | 0.00 | 0.00 | 0.00 |
Cooling | 31.55 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1507.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 313.34 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 169.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 87.13 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2550.12 | 1943.96 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 402.05 | 0.00 | 0.00 | 0.00 |
Cooling | 6.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 311.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 64.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 34.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 18.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 527.41 | 402.05 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 402.05 | 0.00 | 0.00 | 0.00 |
Cooling | 6.52 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 311.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 64.81 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 34.97 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 18.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 527.41 | 402.05 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 0.984338 |
ZONE2 FINE STORAGE DIRECT AIR | 1.91 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3UNITHEATER | 4.49 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATERFAN | 4.49 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATERHEATINGCOIL | 178667.58 |
PSZ-OFFICE HEATING COIL | 28003.97 |
PSZ-FINE STORAGE HEATING COIL | 77855.62 |
User-Specified Heating Design Capacity [W] | |
ZONE3HIRADIANT | 178667.57 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 0.984338 | 0.984338 | 0.984338 | 0.984338 | 0.984338 | 0.984338 | 1.00 | 1.00 | 0.984338 |
PSZ-FINE STORAGE | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.91 | 1.00 | 1.000000 | 1.91 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE OA CONTROLLER | 0.984338 | 0.102285 |
PSZ-FINE STORAGE OA CONTROLLER | 1.91 | 0.424713 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 0.984338 | 0.984338 | 0.984338 | 0.984338 | 17123.43 | 28003.97 | 40.00 | 1.00 |
PSZ-FINE_UNITARY_PACKAGE_DX | 1.91 | 1.91 | 1.91 | 1.91 | 43632.23 | 77855.62 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 0.984340 | 0.492170 | 0.984340 | 16660.99 | 17123.43 | 8561.72 | 17123.43 | 0.780854 | 0.780850 | 0.780850 | 0.780850 |
PSZ-FINE STORAGE COOLING COIL | 1.91 | 0.954105 | 1.91 | 41723.86 | 43632.23 | 21816.12 | 43632.23 | 0.697165 | 0.697170 | 0.697170 | 0.697170 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 0.984338 | 1122.25 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 1.91 | 2088.55 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE FRONT DOOR | |
OFFICE LEFT WALL | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | OFFICE LEFT WALL DOOR | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 5.40 | -2.00 | -14.60 | -16.90 | -11.50 | -6.20 | 4.00 | 13.40 | 18.00 | 19.70 | 17.90 | 12.30 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | International Falls Intl Ap MN USA TMY3 WMO#=727470 | 48.57 | -93.40 | -6.00 | 359.00 | 97086 | 1.1539 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 3.29 | 36.60 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 66 | 42 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 0.00 | 11 | 6 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 14.86 | 6 | 30 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 5.0 | 47.376 | 2.111E-002 | 10.634 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 18.707 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 0.0 | N/A | 0.000 | 8.507 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8.507 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 0.0 | N/A | 0.000 | 8.507 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 11.066 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 5.0 | 2.111E-002 | 47.376 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | BLDG_LIGHT_OFFICE_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 2518.900 | 10.634 | 503.780 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 2518.900 |
2 | FINE STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 11853.648 | 8.507 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 11853.648 |
3 | BULK STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 27263.390 | 8.507 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 27263.390 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 1912.500 | 8.074 | 382.500 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 8200.120 | 2.559 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.2893 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.2893 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL | 19 | 3 | 4 | 0.167 | 0.3378 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL | 21 | 3 | 4 | 0.167 | 0.3378 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 32 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 33 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 35 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 36 | 1 | 1 | 0.167 | 2.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 37 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 38 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 39 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.1360 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.5623E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.5264E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 43 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL | 44 | 3 | 4 | 0.167 | 0.3378 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 45 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.457 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.457 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.861 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.861 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.3522 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 7.276 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 17.71 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 18.92 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.861 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.87112823E-12 | 0.85080972E-17 | 0.21755189E-17 | 0.0000000 |
2 | 1 | -5.2160329 | 0.44465164E-04 | -0.55377147E-04 | 0.16700973E-12 |
3 | 0 | 5.5053245 | 0.28924715 | 0.28934699 | |
4 | 2 | 0.87112823E-12 | 0.85080972E-17 | 0.21755189E-17 | 0.0000000 |
5 | 1 | -5.2160329 | 0.44465164E-04 | -0.55377147E-04 | 0.16700973E-12 |
6 | 0 | 5.5053245 | 0.28924715 | 0.28934699 | |
7 | 4 | 0.81105908E-12 | -0.61566660E-16 | 0.53970606E-14 | 0.11182789E-15 |
8 | 3 | -0.39455327E-03 | 0.24003309E-06 | -0.57329053E-04 | 0.15561420E-12 |
9 | 2 | 1.7627212 | 0.51935632E-02 | 1.1580856 | -0.75642783E-04 |
10 | 1 | -7.0983380 | 0.13367505 | -17.210522 | 0.33785533 |
11 | 0 | 5.5597362 | 0.84856002E-01 | 16.276219 | |
12 | 4 | 0.81105908E-12 | -0.61566660E-16 | 0.53970606E-14 | 0.11182789E-15 |
13 | 3 | -0.39455327E-03 | 0.24003309E-06 | -0.57329053E-04 | 0.15561420E-12 |
14 | 2 | 1.7627212 | 0.51935632E-02 | 1.1580856 | -0.75642783E-04 |
15 | 1 | -7.0983380 | 0.13367505 | -17.210522 | 0.33785533 |
16 | 0 | 5.5597362 | 0.84856002E-01 | 16.276219 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 2.8391346 | 2.8391346 | 2.8391346 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 2.8391346 | 2.8391346 | 2.8391346 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 2.8391346 | 2.8391346 | 2.8391346 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 2.8391346 | 2.8391346 | 2.8391346 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.31240856E-08 | -0.21887765E-14 | 0.14182747E-14 | -0.45258500E-16 |
55 | 6 | 0.39303604E-05 | 0.26006625E-08 | 0.31948254E-02 | -0.26800873E-04 |
56 | 5 | -0.27546567E-03 | 0.15375372E-05 | -0.22400621 | 0.19586362E-02 |
57 | 4 | 0.62896480E-02 | 0.69930755E-04 | 4.8342361 | -0.45310069E-01 |
58 | 3 | -0.55086064E-01 | 0.55565958E-03 | -38.047911 | 0.39894661 |
59 | 2 | 0.19539610 | 0.92379386E-03 | 116.53551 | -1.4186290 |
60 | 1 | -0.28189481 | 0.28115072E-03 | -143.93766 | 2.0495388 |
61 | 0 | 0.13740557 | 0.68297879E-05 | 60.838472 | |
62 | 7 | -0.76172223E-08 | 0.19992769E-15 | -0.36679418E-14 | 0.15936503E-16 |
63 | 6 | 0.20832875E-05 | 0.10921259E-08 | 0.32010154E-02 | -0.26852800E-04 |
64 | 5 | -0.12434769E-03 | 0.63986796E-06 | -0.22435781 | 0.19617397E-02 |
65 | 4 | 0.26900562E-02 | 0.28962460E-04 | 4.8400881 | -0.45366326E-01 |
66 | 3 | -0.23075003E-01 | 0.22921474E-03 | -38.080948 | 0.39931181 |
67 | 2 | 0.81154666E-01 | 0.37960809E-03 | 116.59978 | -1.4194888 |
68 | 1 | -0.11662584 | 0.11498440E-03 | -143.97548 | 2.0501605 |
69 | 0 | 0.56734574E-01 | 0.27738523E-05 | 60.838472 | |
70 | 7 | -0.81392023E-08 | 0.28718252E-15 | -0.25842544E-14 | 0.71742475E-17 |
71 | 6 | 0.20245979E-05 | 0.10259199E-08 | 0.32012942E-02 | -0.26855138E-04 |
72 | 5 | -0.11816234E-03 | 0.60006224E-06 | -0.22437362 | 0.19618793E-02 |
73 | 4 | 0.25345016E-02 | 0.27140048E-04 | 4.8403509 | -0.45368853E-01 |
74 | 3 | -0.21665828E-01 | 0.21464768E-03 | -38.082430 | 0.39932820 |
75 | 2 | 0.76088909E-01 | 0.35527252E-03 | 116.60266 | -1.4195273 |
76 | 1 | -0.10927342 | 0.10751462E-03 | -143.97718 | 2.0501884 |
77 | 0 | 0.53139756E-01 | 0.25964760E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | 0.53970606E-14 | -0.61566660E-16 | 0.81105908E-12 | 0.11182789E-15 |
85 | 3 | -0.57329053E-04 | 0.24003309E-06 | -0.39455327E-03 | 0.15561420E-12 |
86 | 2 | 1.1580856 | 0.51935632E-02 | 1.7627212 | -0.75642783E-04 |
87 | 1 | -17.210522 | 0.13367505 | -7.0983380 | 0.33785533 |
88 | 0 | 16.276219 | 0.84856002E-01 | 5.5597362 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.43_SHGC_0.45 | 28 | 1 | VerySmooth | 2.443 | 0.445 | 0.367 | 0.451 |
2 | SKYLIGHT_U_0.6_SHGC_0.4 | 29 | 1 | VerySmooth | 3.411 | 0.396 | 0.314 | 0.401 |
3 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 30 | 1 | VerySmooth | 3.411 | 0.396 | 0.314 | 0.401 |
4 | SKYLIGHT DOUBLE CLEAR | 34 | 3 | VerySmooth | 3.715 | 0.720 | 0.644 | 0.817 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.91147E-002 | 0.36619 | 0.42642 | 0.42642 | 0.45000 | 0.13324 | 0.16828 | 0.00000 | 0.84000 | 0.84000 | 0.12243 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.31383 | 0.45189 | 0.45189 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 1.61274E-002 | 1.00000 | No | |
3 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.31383 | 0.45189 | 0.45189 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 1.61274E-002 | 1.00000 | No | |
4 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
5 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 20 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | ELECTRIC TANK | 7.5708E-002 | 6154.7 | 1.055 | 0.5308 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 5.0 | 6.083E-002 | 2.568E-004 | 3.964E-004 | 0.217 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 0.889 | 6.381E-004 | 4.064E-004 | 1.084 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 3.431 | 1.071E-003 | 6.993E-004 | 0.350 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 37.760 | 1.178E-002 | N/A | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 0.944 | 2.945E-004 | N/A | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 9554.63732 | 11465.56478 | 0.82028 | 0.98434 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 28.36400 | 1.27032E-002 | 236.87965 | 5.00000 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 12472.77128 | 14967.32554 | 0.36548 | 0.43857 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -32.70000 | 1.83376E-004 | 236.87965 | 5.00000 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 23759.92583 | 28511.91100 | 1.59018 | 1.90821 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 30.10000 | 1.27032E-002 | 1393.40969 | 0.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 57688.18206 | 69225.81848 | 1.42324 | 1.70789 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -32.70000 | 1.83376E-004 | 1393.40969 | 0.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10000 | 1.27032E-002 | 3204.84228 | 0.00000 | 0.97684 | 0.00000 | |
6 | ZONE3 BULK STORAGE | Heating | 148889.64402 | 178667.57282 | 3.73993 | 4.48792 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | -32.70000 | 1.83376E-004 | 3204.84228 | 0.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 14110.85 | 0.98434 | 0.98434 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 16011.76 | 0.43857 | 0.43857 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 34197.11 | 1.90821 | 1.90821 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 72176.94 | 1.70789 | 1.70789 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.98434 |
2 | AirTerminal:SingleDuct:Uncontrolled | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.90821 |
3 | ZoneHVAC:UnitHeater | ZONE3UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 4.48792 |
4 | Fan:ConstantVolume | ZONE3UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 4.48792 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 178667.58356 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3HIRADIANT | User-Specified Heating Design Capacity [W] | 178667.57282 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.98434 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.98434 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.98434 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.98434 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.98434 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.98434 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.90821 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.90821 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.90821 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.90821 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.90821 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 1.90821 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 0.98434 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 1.90821 |
25 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.98434 |
26 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.98434 |
28 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.98434 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.98434 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.98434 |
31 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.98434 |
32 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.49217 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.98434 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 16660.99359 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 17123.43000 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8561.71500 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 17123.43000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.78085 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.78085 |
40 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.78085 |
41 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.78085 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 17123.43000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28003.97223 |
44 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
45 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
46 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.98434 |
47 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1122.25356 |
48 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 28003.97223 |
49 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.90821 |
50 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.90821 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.90821 |
53 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.90821 |
54 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.90821 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.90821 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.95411 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.90821 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 41723.85636 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 43632.23000 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 21816.11500 |
61 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 43632.23000 |
62 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.69716 |
63 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.69717 |
64 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.69717 |
65 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.69717 |
66 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 43632.23000 |
67 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 77855.62337 |
68 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
69 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
70 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.90821 |
71 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2088.54926 |
72 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 77855.62337 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 16359.5 | 11.17 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 42149.6 | 13.90 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | ML KING BIRTHDAY | Holiday | InputFile | 01/16 | 1 |
3 | WASHINGTON'S BIRTHDAY | Holiday | InputFile | 02/20 | 1 |
4 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
5 | FOURTH OF JULY | Holiday | InputFile | 07/04 | 1 |
6 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
7 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
8 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
9 | THANKSGIVING DAY | Holiday | InputFile | 11/23 | 1 |
10 | CHRISTMAS DAY | Holiday | InputFile | 12/25 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 8 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 0.5100584884 | 0.5148861504 | Pass | Pass | 0.5159475552 | 0.4986043794 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 1.4731180368 | 1.1216399227 | Pass | Pass | 0.5102864087 | 0.5000626457 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 1.7293099770E-005 | 5.5736684646E-005 | Pass | Pass | 2.2816217615E-002 | 1.9590928127E-002 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | -32.70 | 0.00 | -32.70 | Wetbulb [C] | 2.40 | 210.00 |
INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 30.10 | 12.40 | 21.10 | Wetbulb [C] | 4.70 | 200.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 39.02 | 30.56 | 0.00 | 90.00 | N |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.322 | 0.338 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.278 | 0.289 | 1393.41 | 1393.41 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.322 | 0.338 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.322 | 0.338 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.322 | 0.338 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.278 | 0.289 | 3204.84 | 3189.98 | 270.00 | 0.00 | |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.136 | 236.88 | 236.88 | 90.00 | 180.00 | ||
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.056 | 1156.53 | 1156.53 | 90.00 | 180.00 | ||
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.053 | 3204.84 | 3204.84 | 90.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.43_SHGC_0.45 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.443 | 0.445 | 0.451 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.43_SHGC_0.45 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.443 | 0.445 | 0.451 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.43_SHGC_0.45 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.443 | 0.445 | 0.451 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.43_SHGC_0.45 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.443 | 0.445 | 0.451 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C5 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C5 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
Total or Average | 32.53 | 2.886 | 0.423 | 0.428 | ||||||||||||
North Total or Average | 6.51 | 2.443 | 0.445 | 0.451 | ||||||||||||
Non-North Total or Average | 26.02 | 2.996 | 0.417 | 0.422 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 1.992 | 2.839 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 1.992 | 2.839 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 1.992 | 2.839 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 1.992 | 2.839 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 1.992 | 2.839 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 1.992 | 2.839 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 1.992 | 2.839 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 1.992 | 2.839 | 1.95 | BULK STORAGE LEFT WALL |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | 10.6337 | 236.88 | 2518.90 | LightsWired | BLDG_LIGHT_OFFICE_SCH | 65.78 | 168.00 | 64.76 | 0.0000 | Y | 30.62 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | 8.5069 | 1393.41 | 11853.65 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 135.00 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | 8.5069 | 3204.84 | 27263.39 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 310.50 |
Interior Lighting Total | 8.6111 | 4835.13 | 41635.94 | 476.13 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 6311.00 | AstronomicalClock | - | 83.52 | 83.52 | 98.94 | |
Exterior Lighting Total | 6311.00 | 98.94 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 17123.43 | 13370.83 | 3752.60 | 0.78 | 3.91 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 43632.23 | 30419.08 | 13213.15 | 0.70 | 3.30 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 16359.5 | 11.17 | ||||
PSZ-FINE STORAGE COOLING COIL | 42149.6 | 13.90 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATERHEATINGCOIL | Coil:Heating:Fuel | 178667.58 | 0.80 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 28003.97 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 77855.62 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 4.49 | 416.97 | 92.91 | 1.00 | 3.19 | General | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.55 | 622.50 | 0.98 | 1122.25 | 1140.11 | 1.00 | 1.37 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.57 | 622.50 | 1.91 | 2088.55 | 1094.51 | 1.00 | 1.29 | General | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
ELECTRIC TANK | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.53 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9554.64 | 11465.56 | 48.40 | 0.820 | 0.984 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 23.90 | 23.90 | 0.00832 | 28.36 | 0.01270 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 23759.93 | 28511.91 | 20.46 | 1.590 | 1.908 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 26.70 | 26.70 | 0.00868 | 30.10 | 0.01270 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 10.00 | 0.00 | 0.00394 | 30.10 | 0.01270 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 12472.77 | 14967.33 | 63.19 | 0.365 | 0.439 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00759 | -32.70 | 0.00018 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 57688.18 | 69225.82 | 49.68 | 1.423 | 1.708 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 15.56 | 15.55 | 0.00619 | -32.70 | 0.00018 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 148889.64 | 178667.57 | 55.75 | 3.740 | 4.488 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | 10.00 | 9.99 | 0.00796 | -32.70 | 0.00018 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 0.98 | 0.98 | 0.44 | 0.44 | 0.9843 | 0.9843 | 0.9843 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 1.91 | 1.91 | 1.71 | 1.71 | 1.9082 | 1.9082 | 1.9082 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | 178667.584 | 178667.584 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | 178667.58 | 178667.58 | 4.487916 | 0.70 | 0.70 | 0.00626771 | 43.33 | 26.55 | 0.01600000 | -32.70 | 0.00018338 | -32.70 | 0.0000 | 9.99 | 0.00796047 | 99.9999 | 178667.57 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 17123.430 | 0.000 | 0.984340 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 17123.43 | 15076.15 | 0.984340 | 24.36 | 16.30 | 0.00877789 | 12.00 | 10.88 | 0.00800000 | 28.36 | 0.01270325 | 20.60 | 10.3912 | 23.90 | 0.00832270 | 43.2062 | 9554.64 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 28003.972 | 28003.972 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 28003.97 | 28003.97 | 0.984338 | 8.51 | 6.99 | 0.00586369 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 10.3912 | 21.10 | 0.00759141 | 46.7759 | 12472.77 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 43632.230 | 0.000 | 1.908210 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 43632.23 | 35578.66 | 1.908210 | 27.46 | 17.98 | 0.00957345 | 12.00 | 10.88 | 0.00800000 | 30.10 | 0.01270324 | 21.10 | 22.2571 | 26.70 | 0.00867742 | 38.1167 | 22717.89 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 77855.623 | 77855.623 | -999.0 | -999.0 | -999.000 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 77855.62 | 77855.62 | 1.908213 | 3.55 | 3.04 | 0.00469903 | 40.00 | 20.66 | 0.00800000 | -32.70 | 0.00018338 | -32.70 | 22.2571 | 15.55 | 0.00619365 | 54.1791 | 57688.18 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 178667.584 | 178667.584 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1034.5832 | 1004.8586 | 1.1539 | ZONE3UNITHEATERFAN | Fan:ConstantVolume | 4.487916 | 5.17871738 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | 178667.58 | 178667.58 | 1.0000 | 5.17871738 | 4.487916 | 0.70 | 0.70 | 0.00626771 | 16381.8 | 43.33 | 26.55 | 0.01600000 | 84847.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 178667.58 | -32.70 | 0.00018338 | -32.70 | 0.00000000 | 0.0000 | 9.99 | 0.00796047 | 9.99 | 0.00796047 | 99.9999 | 178667.57 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 17123.430 | 0.000 | 0.984340 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.1577 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 17123.43 | 15076.15 | 1.0000 | 1.13585439 | 0.984340 | 24.36 | 16.30 | 0.00877789 | 46831.5 | 12.00 | 10.88 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17123.43 | 28.36 | 0.01270325 | 20.60 | 0.10228487 | 10.3912 | 23.90 | 0.00832270 | 23.90 | 0.00832270 | 43.2062 | 9554.64 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28003.972 | 28003.972 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.984338 | 1.13585215 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 28003.97 | 28003.97 | 1.0000 | 1.13585215 | 0.984338 | 8.51 | 6.99 | 0.00586369 | 23313.0 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28003.97 | -32.70 | 0.00018338 | -32.70 | 0.10228487 | 10.3912 | 21.05 | 0.00759141 | 21.10 | 0.00759141 | 46.7759 | 12472.77 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 43632.230 | 0.000 | 1.908210 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.6366 | 1004.8586 | 1.1539 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 16:50:00 | INTERNATIONAL FALLS INTL AP ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 43632.23 | 35578.66 | 1.0000 | 2.20193095 | 1.908210 | 27.46 | 17.98 | 0.00957345 | 52019.5 | 12.00 | 10.88 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 43632.23 | 30.10 | 0.01270324 | 21.10 | 0.42471267 | 22.2571 | 26.70 | 0.00867742 | 26.70 | 0.00867742 | 38.1167 | 22717.89 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 77855.623 | 77855.623 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1539 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.908213 | 2.20193404 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | INTERNATIONAL FALLS INTL AP ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 77855.62 | 77855.62 | 1.0000 | 2.20193404 | 1.908213 | 3.55 | 3.04 | 0.00469903 | 15353.7 | 40.00 | 20.66 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 77855.62 | -32.70 | 0.00018338 | -32.70 | 0.42471267 | 22.2571 | 15.55 | 0.00619365 | 15.55 | 0.00619365 | 54.1791 | 57688.18 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 2758.50 | 2888.50 | 2211.00 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 |
Facility | 2758.50 | 2888.50 | 2211.00 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 239.00 | 2.50 | 119.50 | 2.50 |
ZONE2 FINE STORAGE | 907.17 | 3.83 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 47.67 | 0.00 | 0.00 | 0.00 |
Facility | 1039.67 | 6.33 | 119.50 | 2.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.72 | 5.00 | 1010.76 | 0.347 | 0.412 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.72 | 5.00 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 14 | 14 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
Electricity:Building | 615.74 | 4938.86 | 01-JAN-00:10 | 47606.95 | 29-JUN-12:50 |
Electricity:Zone:ZONE1 OFFICE | 62.57 | 1027.15 | 01-JAN-00:10 | 3852.05 | 02-JAN-08:10 |
InteriorLights:Electricity | 476.13 | 4365.11 | 01-JAN-00:10 | 35189.04 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 30.62 | 453.40 | 01-JAN-00:10 | 1939.55 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 476.13 | 4365.11 | 01-JAN-00:10 | 35189.04 | 02-JAN-09:10 |
Electricity:Zone:ZONE2 FINE STORAGE | 135.00 | 1185.36 | 01-JAN-00:10 | 10075.60 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 135.00 | 1185.36 | 01-JAN-00:10 | 10075.60 | 02-JAN-09:10 |
Electricity:Zone:ZONE3 BULK STORAGE | 418.18 | 2726.34 | 01-JAN-00:10 | 33679.30 | 29-JUN-12:50 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 310.51 | 2726.34 | 01-JAN-00:10 | 23173.88 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Electricity:Plant | 27.51 | 483.00 | 01-JAN-02:00 | 3106.91 | 24-FEB-12:20 |
WaterSystems:Electricity | 27.51 | 483.00 | 01-JAN-02:00 | 3106.91 | 24-FEB-12:20 |
Water Heater:WaterSystems:Electricity | 27.51 | 483.00 | 01-JAN-02:00 | 3106.91 | 24-FEB-12:20 |
Fans:Electricity | 53.39 | 0.00 | 19-MAR-12:00 | 5516.10 | 29-JUN-16:50 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.33 | 0.00 | 01-JAN-00:10 | 2305.29 | 29-JUN-16:50 |
Ventilation (simple):Fans:Electricity | 0.33 | 0.00 | 01-JAN-00:10 | 2305.29 | 29-JUN-16:50 |
ElectricityPurchased:Facility | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
ElectricityPurchased:Plant | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
Cogeneration:ElectricityPurchased | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
ElectricityNet:Plant | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
Cogeneration:ElectricityNet | 805.22 | 5421.86 | 19-MAR-12:00 | 67276.17 | 30-JUN-15:00 |
Electricity:HVAC | 63.02 | 0.00 | 19-MAR-12:00 | 20314.88 | 29-JUN-16:00 |
General:Fans:Electricity | 53.06 | 0.00 | 19-MAR-12:00 | 3627.78 | 02-JAN-14:00 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 9.96 | 0.00 | 01-JAN-00:10 | 17104.08 | 29-JUN-16:00 |
ExteriorLights:Electricity | 98.94 | 0.00 | 01-JAN-08:20 | 6311.00 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 98.94 | 0.00 | 01-JAN-08:20 | 6311.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 1793.32 | 0.00 | 12-MAR-12:00 | 355658.97 | 04-JAN-07:10 |
Gas:HVAC | 1793.32 | 0.00 | 12-MAR-12:00 | 355658.97 | 04-JAN-07:10 |
Heating:Gas | 1793.32 | 0.00 | 12-MAR-12:00 | 355658.97 | 04-JAN-07:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 2742.41 | 0.00 | 19-MAR-12:00 | 549872.41 | 03-JAN-17:10 |
EnergyTransfer:Building | 1315.43 | 0.00 | 19-MAR-12:00 | 266815.17 | 16-DEC-06:10 |
EnergyTransfer:Zone:ZONE1 OFFICE | 78.53 | 0.00 | 01-JAN-00:40 | 24994.35 | 12-JAN-07:10 |
Heating:EnergyTransfer | 1283.52 | 0.00 | 19-MAR-12:00 | 266815.17 | 16-DEC-06:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 64.73 | 0.00 | 01-JAN-00:40 | 24994.35 | 12-JAN-07:10 |
Cooling:EnergyTransfer | 31.91 | 0.00 | 01-JAN-00:10 | 33069.74 | 29-JUN-16:00 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 13.79 | 0.00 | 01-JAN-00:10 | 10184.88 | 29-JUN-16:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 342.14 | 0.00 | 01-JAN-00:40 | 68158.89 | 12-FEB-19:00 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 324.02 | 0.00 | 01-JAN-00:40 | 68158.89 | 12-FEB-19:00 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 18.12 | 0.00 | 01-JAN-00:10 | 24726.63 | 30-JUN-15:10 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 894.77 | 0.00 | 17-JAN-12:50 | 180510.76 | 18-DEC-14:00 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 894.77 | 0.00 | 17-JAN-12:50 | 180510.76 | 18-DEC-14:00 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 1426.98 | 0.00 | 12-MAR-12:00 | 284527.18 | 04-JAN-07:10 |
HeatingCoils:EnergyTransfer | 1388.77 | 0.00 | 12-MAR-12:00 | 284527.18 | 04-JAN-07:10 |
CoolingCoils:EnergyTransfer | 38.21 | 0.00 | 01-JAN-00:10 | 59583.67 | 29-JUN-16:00 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 64.732 | -13.793 | 0.000 | 0.000 | 3.994 | 30.619 | 31.946 | 9.844 | 0.000 | 0.398 | 0.000 | 0.000 | -14.157 | 0.000 | -41.992 | -71.592 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 324.019 | -18.117 | 0.000 | 0.000 | 0.000 | 135.003 | 0.000 | 0.000 | 0.000 | 0.917 | 0.002 | 0.000 | 0.000 | 0.000 | -242.375 | -199.447 |
ZONE3 BULK STORAGE | 894.767 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 310.507 | 107.336 | 15.225 | 0.000 | 11.162 | 0.000 | 0.000 | -14.899 | 0.000 | -897.613 | -426.484 |
Total Facility | 894.767 | 0.000 | 388.751 | -31.910 | 0.000 | 0.000 | 3.994 | 476.129 | 139.282 | 25.070 | 0.000 | 12.476 | 0.002 | 0.000 | -29.056 | 0.000 | -1181.980 | -697.523 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 08-JUL-05:02 | 0.00 | 0.00 | 0.00 | -16290.30 | 0.00 | 0.00 | 35.41 | 579.35 | 573.75 | 0.00 | 0.00 | 0.00 | 15795.72 | 0.00 | -497.91 | 0.00 | -196.01 | 0.00 |
ZONE2 FINE STORAGE | 24-JUL-17:08 | 0.00 | 0.00 | 0.00 | -34101.79 | 0.00 | 0.00 | 0.00 | 1185.36 | 0.00 | 0.00 | 0.00 | 934.13 | 31982.30 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 24-JUL-17:08 | 0.00 | 0.00 | 0.00 | -34101.79 | 0.00 | 0.00 | 0.00 | 4365.11 | 2623.78 | 4921.67 | 0.00 | 1187.02 | 22145.49 | 0.00 | 0.00 | 0.00 | -1141.27 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 18-APR-05:01 | 0.00 | 0.00 | 27627.41 | 0.00 | 0.00 | 0.00 | 55.22 | 579.35 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -201.92 | 0.00 | -567.59 | -28066.21 |
ZONE2 FINE STORAGE | 31-OCT-05:01 | 0.00 | 0.00 | 76021.04 | 0.00 | 0.00 | 0.00 | 0.00 | 1185.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -7482.37 | -69724.03 |
ZONE3 BULK STORAGE | 18-DEC-14:00 | 180509.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 6194.26 | 0.00 | -819.51 | 0.00 | -217257.88 | 0.00 |
Total Facility | 16-DEC-06:01 | 179582.80 | 0.00 | 96798.74 | 0.00 | 0.00 | 0.00 | 60.80 | 4491.05 | 2623.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2170.76 | 0.00 | -196425.50 | -84960.91 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9843 | 0.0000 | 5.0000 | 1.0000 | 0.1023 | 0.9843 | 0.1039 | 1.0000 | 0.1023 | 0.1039 | ||
PSZ-FINE STORAGE | 1.9082 | 0.0000 | 0.0000 | 1.0000 | 0.4247 | 1.9082 | 0.2226 | 1.0000 | 0.4247 | 0.2226 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9843 | 0.0000 | 5.0000 | 1.0000 | 0.1023 | 0.9843 | 1.0000 | 1.0000 | 0.1023 | 0.1039 | ||
PSZ-FINE STORAGE | 1.9082 | 0.0000 | 0.0000 | 1.0000 | 0.4247 | 1.9082 | 1.0000 | 1.0000 | 0.4247 | 0.2226 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 5.0000 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 0.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 5.00 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 0.9843 | 0.9843 | 0.9843 | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 1.9082 | 1.9082 | 1.9082 | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9843 | 0.9843 | 0.9843 | 0.9843 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 1.9082 | 1.9082 | 1.9082 | 1.9082 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 0.9843 | 0.9843 | 0.9843 | 0.1023 | 0.2332 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 1.9082 | 1.9082 | 1.9082 | 0.4247 | 0.2487 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9843 | 0.9843 | 0.9843 | 0.9843 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 1.9082 | 1.9082 | 1.9082 | 1.9082 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** International Falls Intl Ap MN USA TMY3 WMO#=727470 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 0.00 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 119.50 |
Number of hours cooling loads not met | 2.50 |
Number of hours not met | 122.00 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 1793.32 | 355658.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 9.96 | 17104.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 476.13 | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 98.94 | 6311.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.28 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.33 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 53.06 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 27.51 | 3106.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.28 | 805.22 |
Natural Gas | 0.00 | 1793.32 |
Additional | 0.00 | 0.00 |
Total | 139.28 | 2598.53 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 98.47 |
Space Heating | 0.00 |
Space Cooling | 2.06 |
Fans (All) | 11.04 |
Service Water Heating | 5.69 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 166.53 |
Subtotal | 166.53 |
Natural Gas [MJ/m2] | |
Space Heating | 370.89 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 370.89 |
Subtotal | 370.89 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 18.32 |
Space Heating | 69.01 |
Space Cooling | 0.38 |
Fans (All) | 2.05 |
Service Water Heating | 1.06 |
Receptacle Equipment | 5.36 |
Miscellaneous | 3.81 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
OFFICE LIGHT SCHEDULE | 3792. | 8760. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
STORAGE LIGHT SCHEDULE | 3232. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
OFFICE LIGHT WITH SENSOR SCHEDULE | 3430. | 8760. |
STORAGE LIGHT WITH SENSOR SCHEDULE | 2877. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BLDG_LIGHT_OFFICE_SCH | 3430. | 8760. |
BLDG_LIGHT_STORAGE_SCH | 3232. | 8760. |
BLDG_OCC_SCH | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | HEATING SETPOINT WITH SB | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 7
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_MN_INTERNATIONALFALLS
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.468132E+12 |
February | 0.000 | 0.348051E+12 |
March | 0.000 | 0.234429E+12 |
April | 0.000 | 0.795918E+11 |
May | 0.000 | 0.348070E+10 |
June | 0.000 | 0.897662E+08 |
July | 0.000 | 0.000 |
August | 0.000 | 7302112.200 |
September | 0.000 | 0.101912E+10 |
October | 0.000 | 0.293303E+11 |
November | 0.000 | 0.187684E+12 |
December | 0.000 | 0.441505E+12 |
Annual Sum or Average | 0.179332E+13 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.468132E+12 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 100139.37 | 1001.39 | 11-JAN-08:05 | -27.0 | -27.1 | 0.193631E+09 | 236.59 | 18-JAN-11:00 | -6.1 | -6.3 |
February | 0.00 | 0.00 | 01-FEB-00:05 | -23.1 | -23.4 | 0.178782E+09 | 236.59 | 04-FEB-10:20 | -4.1 | -4.8 |
March | 0.00 | 0.00 | 01-MAR-00:03 | -1.3 | -3.2 | 0.210350E+09 | 236.59 | 20-MAR-15:09 | 0.00 | -0.3 |
April | 2253566.30 | 211.69 | 24-APR-15:00 | 8.90 | 5.06 | 0.197687E+09 | 297.09 | 13-APR-15:00 | 20.00 | 8.07 |
May | 0.103232E+10 | 9444.75 | 26-MAY-05:03 | 19.40 | 15.68 | 0.236007E+09 | 301.60 | 19-MAY-10:00 | 16.70 | 13.04 |
June | 0.284084E+10 | 13792.32 | 27-JUN-05:02 | 15.68 | 14.97 | 0.255513E+09 | 301.61 | 21-JUN-14:00 | 24.40 | 16.98 |
July | 0.480576E+10 | 16290.19 | 08-JUL-05:02 | 11.70 | 10.46 | 0.248771E+09 | 301.61 | 29-JUL-15:00 | 30.60 | 21.38 |
August | 0.395461E+10 | 15439.83 | 03-AUG-05:03 | 11.10 | 10.18 | 0.267712E+09 | 302.85 | 01-AUG-07:10 | 17.12 | 16.67 |
September | 0.112057E+10 | 14953.05 | 02-SEP-05:02 | 13.80 | 10.54 | 0.230170E+09 | 301.61 | 02-SEP-13:50 | 15.33 | 13.44 |
October | 37159752.10 | 736.69 | 19-OCT-15:40 | 21.87 | 13.56 | 0.199517E+09 | 305.19 | 19-OCT-15:39 | 21.87 | 13.56 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.50 | 0.187400E+09 | 260.27 | 01-NOV-15:00 | 17.80 | 13.25 |
December | 0.00 | 0.00 | 01-DEC-00:02 | -8.8 | -9.9 | 0.194336E+09 | 236.59 | 30-DEC-08:20 | -4.5 | -5.2 |
Annual Sum or Average | 0.137936E+11 | 0.259988E+10 | ||||||||
Minimum of Months | 0.00 | 0.00 | -27.0 | -27.1 | 0.178782E+09 | 236.59 | -6.1 | -6.3 | ||
Maximum of Months | 0.480576E+10 | 16290.19 | 21.87 | 15.68 | 0.267712E+09 | 305.19 | 30.60 | 21.38 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | -21.9 | -22.1 | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 |
February | 52539861.41 | 3294.82 | 08-FEB-14:00 | 5.00 | -0.2 | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.4 |
March | 0.444312E+09 | 6360.06 | 23-MAR-13:00 | -1.1 | -4.4 | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.2 |
April | 0.741122E+09 | 7470.95 | 28-APR-06:05 | -3.4 | -4.5 | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.37 |
May | 0.128153E+10 | 5378.66 | 25-MAY-15:10 | 28.93 | 19.64 | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.3 |
June | 0.312217E+10 | 31860.63 | 30-JUN-18:23 | 28.90 | 19.64 | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 |
July | 0.615005E+10 | 34102.81 | 24-JUL-17:08 | 28.80 | 19.12 | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.56 |
August | 0.324937E+10 | 27019.03 | 08-AUG-17:12 | 29.03 | 22.84 | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 |
September | 0.174368E+10 | 10124.78 | 01-SEP-15:00 | 26.10 | 17.80 | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 |
October | 0.113669E+10 | 5046.80 | 25-OCT-09:20 | 1.10 | 1.02 | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 |
November | 0.195685E+09 | 7650.47 | 06-NOV-07:05 | -3.9 | -4.1 | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.50 |
December | 0.00 | 0.00 | 01-DEC-00:02 | -8.8 | -9.9 | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 |
Annual Sum or Average | 0.181171E+11 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -21.9 | -22.1 | 0.00 | 0.00 | -23.1 | -23.4 | ||
Maximum of Months | 0.615005E+10 | 34102.81 | 29.03 | 22.84 | 0.00 | 0.00 | 19.75 | 18.15 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | -21.9 | -22.1 | 0.00 | 0.00 | 01-JAN-00:10 | -21.9 | -22.1 |
February | 0.00 | 0.00 | 01-FEB-00:05 | -23.1 | -23.4 | 0.00 | 0.00 | 01-FEB-00:10 | -23.1 | -23.4 |
March | 0.00 | 0.00 | 01-MAR-00:03 | -1.3 | -3.2 | 0.00 | 0.00 | 01-MAR-00:10 | -1.3 | -3.2 |
April | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.37 | 0.00 | 0.00 | 01-APR-00:10 | 3.52 | 0.37 |
May | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.3 | 0.00 | 0.00 | 01-MAY-00:10 | -0.0 | -1.3 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 | 8.93 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.56 | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 | 13.56 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 | 15.36 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 | 18.15 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 | 0.00 | 0.00 | 01-OCT-00:10 | 7.52 | 6.57 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.50 | 0.00 | 0.00 | 01-NOV-00:10 | 3.60 | 0.50 |
December | 0.00 | 0.00 | 01-DEC-00:02 | -8.8 | -9.9 | 0.00 | 0.00 | 01-DEC-00:10 | -8.8 | -9.9 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -23.1 | -23.4 | 0.00 | 0.00 | -23.1 | -23.4 | ||
Maximum of Months | 0.00 | 0.00 | 19.75 | 18.15 | 0.00 | 0.00 | 19.75 | 18.15 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.147029E+11 | 26430.57 | 31-JAN-06:31 | -14.1 |
February | 0.109247E+11 | 26837.26 | 21-FEB-06:01 | 2.80 |
March | 0.963461E+10 | 26949.15 | 17-MAR-05:31 | -8.9 |
April | 0.478398E+10 | 27627.27 | 18-APR-05:01 | 11.78 |
May | 0.105072E+10 | 26975.14 | 15-MAY-05:01 | 6.87 |
June | 89608078.91 | 9245.79 | 01-JUN-05:03 | 14.08 |
July | 8059502.97 | 567.43 | 12-JUL-06:10 | 17.15 |
August | 23160537.12 | 1977.51 | 18-AUG-06:15 | 11.10 |
September | 0.583113E+09 | 27181.29 | 30-SEP-05:01 | 10.00 |
October | 0.319706E+10 | 27509.80 | 31-OCT-05:01 | 10.00 |
November | 0.666116E+10 | 27525.15 | 01-NOV-05:01 | 10.60 |
December | 0.130736E+11 | 26949.95 | 04-DEC-06:31 | -9.4 |
Annual Sum or Average | 0.647327E+11 | |||
Minimum of Months | 8059502.97 | 567.43 | -14.1 | |
Maximum of Months | 0.147029E+11 | 27627.27 | 17.15 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.787417E+11 | 72961.09 | 16-JAN-16:02 | -1.7 |
February | 0.599335E+11 | 75313.89 | 20-FEB-18:02 | 5.40 |
March | 0.421512E+11 | 73457.09 | 27-MAR-21:03 | 3.90 |
April | 0.190744E+11 | 74164.64 | 09-APR-13:02 | 2.70 |
May | 0.136506E+10 | 69713.05 | 01-MAY-05:01 | -3.4 |
June | 0.163886E+09 | 2239.99 | 06-JUN-13:00 | 25.60 |
July | 2591058.97 | 633.43 | 10-JUL-11:00 | 23.90 |
August | 17153953.26 | 829.43 | 19-AUG-16:10 | 22.62 |
September | 98987954.91 | 51102.59 | 28-SEP-05:08 | 6.70 |
October | 0.104545E+11 | 76021.11 | 31-OCT-05:01 | 10.00 |
November | 0.367445E+11 | 74189.31 | 20-NOV-00:03 | 5.50 |
December | 0.752718E+11 | 73148.03 | 05-DEC-04:42 | -1.3 |
Annual Sum or Average | 0.324019E+12 | |||
Minimum of Months | 2591058.97 | 633.43 | -3.4 | |
Maximum of Months | 0.787417E+11 | 76021.11 | 25.60 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.243420E+12 | 180232.50 | 04-JAN-09:55 | -28.9 |
February | 0.180148E+12 | 180012.04 | 12-FEB-22:30 | -16.1 |
March | 0.113870E+12 | 149244.14 | 15-MAR-05:00 | -22.2 |
April | 0.316355E+11 | 92406.51 | 04-APR-18:52 | -7.2 |
May | 0.198299E+09 | 16230.00 | 01-MAY-04:00 | -2.8 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 11.35 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 15.83 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 17.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 19.75 |
October | 0.466443E+10 | 45591.79 | 31-OCT-20:53 | -2.2 |
November | 0.909801E+11 | 125562.62 | 25-NOV-01:51 | -15.6 |
December | 0.229852E+12 | 180510.76 | 18-DEC-14:00 | -22.8 |
Annual Sum or Average | 0.894768E+12 | |||
Minimum of Months | 0.00 | 0.00 | -28.9 | |
Maximum of Months | 0.243420E+12 | 180510.76 | 19.75 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.256100E+10 | 1939.55 | 02-JAN-08:09 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.233575E+10 | 1939.55 | 01-FEB-08:09 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.266872E+10 | 1939.55 | 01-MAR-08:09 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.252182E+10 | 1939.55 | 01-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.261486E+10 | 1939.55 | 01-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.257569E+10 | 1939.55 | 01-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.256100E+10 | 1939.55 | 01-JUL-07:10 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.266872E+10 | 1939.55 | 01-AUG-07:10 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.252182E+10 | 1939.55 | 01-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.256100E+10 | 1939.55 | 02-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.246796E+10 | 1939.55 | 01-NOV-07:10 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.256100E+10 | 1939.55 | 01-DEC-08:09 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.306193E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.233575E+10 | 1939.55 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.266872E+10 | 1939.55 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.112294E+11 | 10075.60 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.102778E+11 | 10075.60 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.118738E+11 | 10075.60 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.111270E+11 | 10075.60 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.115516E+11 | 10075.60 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.114492E+11 | 10075.60 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.112294E+11 | 10075.60 | 01-JUL-08:09 | 0.00 | 0.00 |
August | 0.118738E+11 | 10075.60 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.111270E+11 | 10075.60 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.112294E+11 | 10075.60 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.108048E+11 | 10075.60 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.112294E+11 | 10075.60 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.135003E+12 | ||||
Minimum of Months | 0.102778E+11 | 10075.60 | 0.00 | 0.00 | |
Maximum of Months | 0.118738E+11 | 10075.60 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.258277E+11 | 23173.88 | 02-JAN-09:09 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.236390E+11 | 23173.88 | 01-FEB-09:09 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.273097E+11 | 23173.88 | 01-MAR-09:09 | 0.956462E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.255921E+11 | 23173.88 | 01-APR-08:09 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.265687E+11 | 23173.88 | 01-MAY-08:09 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.263332E+11 | 23173.88 | 01-JUN-08:09 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.258277E+11 | 23173.88 | 01-JUL-08:09 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.273097E+11 | 23173.88 | 01-AUG-08:09 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.255921E+11 | 23173.88 | 01-SEP-08:09 | 0.885613E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.258277E+11 | 23173.88 | 02-OCT-08:09 | 0.885613E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.248511E+11 | 23173.88 | 01-NOV-08:09 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.258277E+11 | 23173.88 | 01-DEC-09:09 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.310507E+12 | 0.107336E+12 | ||||
Minimum of Months | 0.236390E+11 | 23173.88 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.273097E+11 | 23173.88 | 0.956462E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.773035E+10 |
February | 0.500553E+09 | 0.233575E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.604585E+10 |
March | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.524346E+10 |
April | 0.544079E+09 | 0.252182E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8145349.91 | 0.314991E+10 |
May | 0.565842E+09 | 0.261486E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 56453856.11 | 0.148386E+10 |
June | 0.565842E+09 | 0.257569E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134438E+09 | 0.841256E+09 |
July | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128230E+09 | 0.659941E+09 |
August | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 67831670.14 | 0.103439E+10 |
September | 0.544079E+09 | 0.252182E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2982145.95 | 0.172552E+10 |
October | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.273509E+10 |
November | 0.522316E+09 | 0.246796E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.426383E+10 |
December | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.707841E+10 |
Annual Sum or Average | 0.659424E+10 | 0.306193E+11 | 0.319458E+11 | 0.398081E+09 | 0.419919E+11 | ||||
Minimum of Months | 0.500553E+09 | 0.233575E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.659941E+09 |
Maximum of Months | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.134438E+09 | 0.773035E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.435192E+11 |
February | 0.00 | 0.102778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366119E+11 |
March | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.261158E+11 |
April | 0.00 | 0.111270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149424E+09 | 0.183941E+11 |
May | 0.00 | 0.115516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135395E+09 | 0.777336E+10 |
June | 0.00 | 0.114492E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314830E+09 | 0.547396E+10 |
July | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240388E+09 | 0.531021E+10 |
August | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 63957423.53 | 0.690198E+10 |
September | 0.00 | 0.111270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8190570.73 | 0.897100E+10 |
October | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4468799.32 | 0.124946E+11 |
November | 0.00 | 0.108048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.265183E+11 |
December | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.442904E+11 |
Annual Sum or Average | 0.135003E+12 | 0.916653E+09 | 0.242375E+12 | ||||||
Minimum of Months | 0.00 | 0.102778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.531021E+10 |
Maximum of Months | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.314830E+09 | 0.442904E+11 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.128890E+12 |
February | 0.00 | 0.236390E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104364E+12 |
March | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 210130.30 | 0.698104E+11 |
April | 0.00 | 0.255921E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203657E+10 | 0.391594E+11 |
May | 0.00 | 0.265687E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324188E+10 | 0.184690E+11 |
June | 0.00 | 0.263332E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.554717E+09 | 0.158896E+11 |
July | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30289062.62 | 0.225695E+11 |
August | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135813E+09 | 0.258450E+11 |
September | 0.00 | 0.255921E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115874E+09 | 0.308887E+11 |
October | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.866729E+09 | 0.279871E+11 |
November | 0.00 | 0.248511E+11 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.310159E+09 | 0.634371E+11 |
December | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.126145E+12 |
Annual Sum or Average | 0.310507E+12 | 0.107336E+12 | 0.729224E+10 | 0.673455E+12 | |||||
Minimum of Months | 0.00 | 0.236390E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.158896E+11 |
Maximum of Months | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324188E+10 | 0.128890E+12 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 659.25 | 02-JAN-08:09 | 1939.55 | 02-JAN-08:09 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 23178.97 | 05-JAN-07:05 |
February | 659.25 | 01-FEB-08:09 | 1939.55 | 01-FEB-08:09 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 22546.57 | 14-FEB-07:02 |
March | 659.25 | 01-MAR-08:09 | 1939.55 | 01-MAR-08:09 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 19339.12 | 15-MAR-06:03 |
April | 659.25 | 01-APR-07:10 | 1939.55 | 01-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 451.94 | 23-APR-16:00 | 13184.89 | 05-APR-06:10 |
May | 659.25 | 01-MAY-07:10 | 1939.55 | 01-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1822.66 | 25-MAY-17:00 | 9092.10 | 01-MAY-06:10 |
June | 659.25 | 01-JUN-07:10 | 1939.55 | 01-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4165.21 | 29-JUN-16:10 | 4549.30 | 02-JUN-06:10 |
July | 659.25 | 01-JUL-07:10 | 1939.55 | 01-JUL-07:10 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2029.86 | 28-JUL-16:10 | 4436.10 | 18-JUL-06:05 |
August | 659.25 | 01-AUG-07:10 | 1939.55 | 01-AUG-07:10 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2576.98 | 08-AUG-16:10 | 5209.30 | 25-AUG-06:03 |
September | 659.25 | 01-SEP-07:10 | 1939.55 | 01-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 688.62 | 01-SEP-16:10 | 7075.30 | 06-SEP-06:05 |
October | 659.25 | 02-OCT-07:10 | 1939.55 | 02-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 12586.81 | 30-OCT-07:00 |
November | 659.25 | 01-NOV-07:10 | 1939.55 | 01-NOV-07:10 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 16437.00 | 29-NOV-07:10 |
December | 659.25 | 01-DEC-08:09 | 1939.55 | 01-DEC-08:09 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 22891.37 | 20-DEC-07:02 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4436.10 | |||||
Maximum of Months | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 4165.21 | 23178.97 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 10075.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 54366.12 | 04-JAN-16:03 |
February | 0.00 | 10075.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 58381.60 | 12-FEB-23:00 |
March | 0.00 | 10075.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 40894.40 | 14-MAR-15:10 |
April | 0.00 | 10075.60 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7422.40 | 23-APR-16:00 | 33417.46 | 26-APR-15:10 |
May | 0.00 | 10075.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3442.99 | 10-MAY-15:10 | 14315.70 | 20-MAY-06:10 |
June | 0.00 | 10075.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9170.82 | 29-JUN-16:00 | 13231.70 | 09-JUN-08:00 |
July | 0.00 | 10075.60 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6272.08 | 15-JUL-15:10 | 10034.22 | 08-JUL-15:05 |
August | 0.00 | 10075.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4732.66 | 08-AUG-16:00 | 17579.19 | 17-AUG-15:05 |
September | 0.00 | 10075.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1213.24 | 24-SEP-15:00 | 13763.42 | 20-SEP-06:10 |
October | 0.00 | 10075.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 916.79 | 19-OCT-15:10 | 21981.63 | 31-OCT-17:00 |
November | 0.00 | 10075.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 32586.47 | 22-NOV-01:50 |
December | 0.00 | 10075.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 66727.90 | 18-DEC-16:03 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10034.22 | |||
Maximum of Months | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9170.82 | 66727.90 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 23173.88 | 02-JAN-09:09 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 192005.43 | 04-JAN-12:00 |
February | 0.00 | 23173.88 | 01-FEB-09:09 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 153004.93 | 12-FEB-22:52 |
March | 0.00 | 23173.88 | 01-MAR-09:09 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 260.28 | 26-MAR-16:00 | 97587.32 | 14-MAR-16:00 |
April | 0.00 | 23173.88 | 01-APR-08:09 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 39401.17 | 23-APR-16:00 | 67860.58 | 26-APR-15:00 |
May | 0.00 | 23173.88 | 01-MAY-08:09 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 24064.39 | 10-MAY-15:00 | 35024.71 | 20-MAY-07:10 |
June | 0.00 | 23173.88 | 01-JUN-08:09 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9779.88 | 29-JUN-12:43 | 45929.88 | 09-JUN-09:00 |
July | 0.00 | 23173.88 | 01-JUL-08:09 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6559.55 | 15-JUL-14:00 | 56483.73 | 03-JUL-10:55 |
August | 0.00 | 23173.88 | 01-AUG-08:09 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6595.68 | 08-AUG-16:00 | 66767.73 | 17-AUG-14:00 |
September | 0.00 | 23173.88 | 01-SEP-08:09 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6325.52 | 24-SEP-15:00 | 38474.31 | 20-SEP-07:10 |
October | 0.00 | 23173.88 | 02-OCT-08:09 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21975.88 | 19-OCT-15:00 | 44957.96 | 05-OCT-08:00 |
November | 0.00 | 23173.88 | 01-NOV-08:09 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 10906.78 | 01-NOV-14:00 | 82150.27 | 25-NOV-11:00 |
December | 0.00 | 23173.88 | 01-DEC-09:09 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 174126.73 | 18-DEC-15:00 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35024.71 | ||||
Maximum of Months | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 39401.17 | 192005.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1001.39 | 11-JAN-08:05 | 3955.50 | 11637.32 | 11475.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2755.80 |
February | 0.00 | 01-FEB-00:05 | 0.00 | 906.80 | 1147.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1786.58 |
March | 0.00 | 01-MAR-00:03 | 0.00 | 1813.61 | 2295.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 591.79 |
April | 211.69 | 24-APR-15:00 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 818.06 |
May | 9444.75 | 26-MAY-05:03 | 217.55 | 1738.04 | 1721.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 334.56 |
June | 13792.32 | 27-JUN-05:02 | 362.59 | 2896.74 | 2868.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 569.56 |
July | 16290.19 | 08-JUL-05:02 | 362.59 | 2896.74 | 2868.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196.01 |
August | 15439.83 | 03-AUG-05:03 | 290.07 | 2317.39 | 2295.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 814.45 |
September | 14953.05 | 02-SEP-05:02 | 362.59 | 2896.74 | 2868.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.40 |
October | 736.69 | 19-OCT-15:40 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 218.79 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 453.40 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 551.60 |
December | 0.00 | 01-DEC-00:02 | 0.00 | 2720.41 | 3442.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1009.05 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 453.40 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 196.01 | |
Maximum of Months | 16290.19 | 3955.50 | 11637.32 | 11475.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2755.80 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:01 | 0.00 | 11853.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19194.12 |
February | 3294.82 | 08-FEB-14:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1622.78 |
March | 6360.06 | 23-MAR-13:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 7470.95 | 28-APR-06:05 | 0.00 | 28448.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12558.40 |
May | 5378.66 | 25-MAY-15:10 | 0.00 | 8890.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1126.61 | 0.00 |
June | 31860.63 | 30-JUN-18:23 | 0.00 | 3556.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1241.47 | 0.00 |
July | 34102.81 | 24-JUL-17:08 | 0.00 | 4741.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 934.13 | 0.00 |
August | 27019.03 | 08-AUG-17:12 | 0.00 | 4741.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1913.56 | 0.00 |
September | 10124.78 | 01-SEP-15:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.79 |
October | 5046.80 | 25-OCT-09:20 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 543.87 |
November | 7650.47 | 06-NOV-07:05 | 0.00 | 28448.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12095.85 |
December | 0.00 | 01-DEC-00:02 | 0.00 | 7112.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16044.02 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 3556.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 34102.81 | 0.00 | 28448.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1913.56 | 19194.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:01 | 0.00 | 27263.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 48218.72 |
February | 0.00 | 01-FEB-00:05 | 0.00 | 5452.68 | 4100.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76845.26 |
March | 0.00 | 01-MAR-00:03 | 0.00 | 10905.36 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20366.36 |
April | 0.00 | 01-APR-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14244.48 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3300.55 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10653.26 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7269.29 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11503.29 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6783.05 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 2726.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7947.71 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14233.92 |
December | 0.00 | 01-DEC-00:02 | 0.00 | 16358.03 | 12300.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 39831.83 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 2726.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3300.55 | |
Maximum of Months | 0.00 | 0.00 | 27263.39 | 12300.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76845.26 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.707719E+11 | 53004.84 | 09-JAN-08:09 | 0.468132E+12 | 355658.97 | 03-JAN-17:10 |
February | 0.634486E+11 | 51593.78 | 24-FEB-15:00 | 0.348051E+12 | 353880.62 | 01-FEB-06:10 |
March | 0.708869E+11 | 51593.12 | 01-MAR-13:09 | 0.234429E+12 | 313059.54 | 15-MAR-05:10 |
April | 0.644156E+11 | 51520.35 | 01-APR-12:00 | 0.795918E+11 | 184218.03 | 04-APR-18:30 |
May | 0.651763E+11 | 55898.19 | 25-MAY-14:50 | 0.348070E+10 | 60741.52 | 01-MAY-05:10 |
June | 0.659043E+11 | 67276.17 | 30-JUN-14:00 | 89766194.16 | 8278.04 | 02-JUN-06:10 |
July | 0.670797E+11 | 64999.79 | 15-JUL-14:30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.692289E+11 | 60228.39 | 08-AUG-14:00 | 7302112.20 | 2987.48 | 18-AUG-06:30 |
September | 0.643276E+11 | 56669.24 | 01-SEP-14:00 | 0.101912E+10 | 24896.64 | 28-SEP-06:10 |
October | 0.664417E+11 | 50901.79 | 31-OCT-12:50 | 0.293303E+11 | 113654.22 | 30-OCT-06:00 |
November | 0.665647E+11 | 52954.78 | 30-NOV-16:30 | 0.187684E+12 | 246255.81 | 25-NOV-02:09 |
December | 0.709692E+11 | 52960.96 | 30-DEC-16:00 | 0.441505E+12 | 355658.97 | 18-DEC-17:10 |
Annual Sum or Average | 0.805215E+12 | 0.179332E+13 | ||||
Minimum of Months | 0.634486E+11 | 50901.79 | 0.00 | 0.00 | ||
Maximum of Months | 0.709692E+11 | 67276.17 | 0.468132E+12 | 355658.97 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.396181E+11 | 0.108562E+11 | 0.115358E+11 | 0.00 | 0.636018E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.240162E+10 | 0.00 |
February | 0.362526E+11 | 0.891744E+10 | 0.105871E+11 | 0.00 | 0.548450E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.220694E+10 | 0.00 |
March | 0.418523E+11 | 0.866753E+10 | 0.123357E+11 | 0.00 | 0.553427E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.249711E+10 | 0.00 |
April | 0.392410E+11 | 0.717561E+10 | 0.114862E+11 | 0.00 | 0.417211E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.234067E+10 | 0.00 |
May | 0.407352E+11 | 0.632362E+10 | 0.119357E+11 | 0.00 | 0.335620E+10 | 0.00 | 0.00 | 0.459666E+09 | 0.00 | 0.00 | 0.00 | 0.236587E+10 | 0.00 |
June | 0.403581E+11 | 0.552844E+10 | 0.118862E+11 | 0.00 | 0.346546E+10 | 0.00 | 0.00 | 0.241074E+10 | 0.00 | 0.00 | 0.00 | 0.225541E+10 | 0.00 |
July | 0.396181E+11 | 0.599040E+10 | 0.115358E+11 | 0.00 | 0.344436E+10 | 0.00 | 0.00 | 0.427355E+10 | 0.00 | 0.00 | 0.00 | 0.221746E+10 | 0.00 |
August | 0.418523E+11 | 0.692569E+10 | 0.123357E+11 | 0.00 | 0.344682E+10 | 0.00 | 0.00 | 0.241260E+10 | 0.00 | 0.00 | 0.00 | 0.225584E+10 | 0.00 |
September | 0.392410E+11 | 0.785720E+10 | 0.114862E+11 | 0.00 | 0.318513E+10 | 0.00 | 0.00 | 0.400212E+09 | 0.00 | 0.00 | 0.00 | 0.215786E+10 | 0.00 |
October | 0.396181E+11 | 0.937562E+10 | 0.115358E+11 | 0.00 | 0.366409E+10 | 0.00 | 0.00 | 4400908.97 | 0.00 | 0.00 | 0.00 | 0.224365E+10 | 0.00 |
November | 0.381239E+11 | 0.101746E+11 | 0.110862E+11 | 0.00 | 0.496355E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221637E+10 | 0.00 |
December | 0.396181E+11 | 0.111478E+11 | 0.115358E+11 | 0.00 | 0.631424E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.235336E+10 | 0.00 |
Annual Sum or Average | 0.476129E+12 | 0.989401E+11 | 0.139282E+12 | 0.533909E+11 | 0.00 | 0.996117E+10 | 0.275122E+11 | ||||||
Minimum of Months | 0.362526E+11 | 0.552844E+10 | 0.105871E+11 | 0.00 | 0.318513E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.215786E+10 | 0.00 |
Maximum of Months | 0.418523E+11 | 0.111478E+11 | 0.123357E+11 | 0.00 | 0.636018E+10 | 0.00 | 0.00 | 0.427355E+10 | 0.00 | 0.00 | 0.00 | 0.249711E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.468132E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.348051E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.234429E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.795918E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.348070E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 89766194.16 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 7302112.20 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.101912E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.293303E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.187684E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.441505E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.179332E+13 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.468132E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 35189.04 | 02-JAN-09:09 | 6311.00 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 3627.78 | 02-JAN-13:00 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 35189.04 | 01-FEB-09:09 | 6311.00 | 01-FEB-00:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 3627.78 | 01-FEB-10:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 35189.04 | 01-MAR-09:09 | 6311.00 | 01-MAR-00:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 3627.78 | 02-MAR-13:39 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 35189.04 | 01-APR-08:09 | 6311.00 | 01-APR-00:10 | 10112.62 | 01-APR-07:10 | 0.00 | 3627.78 | 03-APR-08:39 | 0.00 | 0.00 | 01-APR-00:10 |
May | 35189.04 | 01-MAY-08:09 | 6311.00 | 01-MAY-00:10 | 10112.62 | 01-MAY-07:10 | 0.00 | 3210.80 | 02-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 35189.04 | 01-JUN-08:09 | 6311.00 | 01-JUN-00:10 | 10112.62 | 01-JUN-07:10 | 0.00 | 5516.10 | 29-JUN-16:49 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 35189.04 | 01-JUL-08:09 | 6311.00 | 01-JUL-00:10 | 10112.62 | 01-JUL-07:10 | 0.00 | 5516.10 | 15-JUL-14:30 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 35189.04 | 01-AUG-08:09 | 6311.00 | 01-AUG-00:10 | 10112.62 | 01-AUG-07:10 | 0.00 | 3210.80 | 05-AUG-16:49 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 35189.04 | 01-SEP-08:09 | 6311.00 | 01-SEP-00:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 3210.80 | 01-SEP-09:39 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 35189.04 | 02-OCT-08:09 | 6311.00 | 01-OCT-00:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 3627.78 | 12-OCT-10:39 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 35189.04 | 01-NOV-08:09 | 6311.00 | 01-NOV-00:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 3627.78 | 03-NOV-15:00 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 35189.04 | 01-DEC-09:09 | 6311.00 | 01-DEC-00:10 | 10112.62 | 01-DEC-08:09 | 0.00 | 3627.78 | 01-DEC-08:20 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 35189.04 | 6311.00 | 10112.62 | 0.00 | 3210.80 | 0.00 | 0.00 | |||||
Maximum of Months | 35189.04 | 6311.00 | 10112.62 | 0.00 | 5516.10 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 3072.82 | 31-JAN-12:30 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 3106.91 | 24-FEB-12:20 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 3102.39 | 06-MAR-12:30 | 0.00 |
April | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 3040.85 | 01-APR-11:50 | 0.00 |
May | 5460.48 | 25-MAY-15:00 | 0.00 | 0.00 | 0.00 | 2886.73 | 01-MAY-11:30 | 0.00 |
June | 17104.08 | 29-JUN-15:00 | 0.00 | 0.00 | 0.00 | 2654.74 | 01-JUN-11:20 | 0.00 |
July | 12850.81 | 15-JUL-15:09 | 0.00 | 0.00 | 0.00 | 2415.83 | 01-JUL-11:50 | 0.00 |
August | 11060.91 | 08-AUG-15:50 | 0.00 | 0.00 | 0.00 | 2227.23 | 01-AUG-11:09 | 0.00 |
September | 6363.47 | 01-SEP-14:00 | 0.00 | 0.00 | 0.00 | 2258.77 | 27-SEP-11:00 | 0.00 |
October | 428.32 | 19-OCT-15:39 | 0.00 | 0.00 | 0.00 | 2480.28 | 30-OCT-11:00 | 0.00 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 2727.53 | 30-NOV-12:00 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 2923.37 | 28-DEC-12:30 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 2227.23 | 0.00 | ||
Maximum of Months | 17104.08 | 0.00 | 0.00 | 0.00 | 3106.91 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 53004.84 | 09-JAN-08:09 | 31277.33 | 10112.62 | 6311.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 51593.78 | 24-FEB-15:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 51593.12 | 01-MAR-13:09 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 51520.35 | 01-APR-12:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 55898.19 | 25-MAY-14:50 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3210.80 | 0.00 | 0.00 | 5208.56 | 0.00 |
June | 67276.17 | 30-JUN-14:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 5516.10 | 0.00 | 0.00 | 14645.51 | 0.00 |
July | 64999.79 | 15-JUL-14:30 | 35189.04 | 10112.62 | 0.00 | 0.00 | 5516.10 | 0.00 | 0.00 | 12377.75 | 0.00 |
August | 60228.39 | 08-AUG-14:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3210.80 | 0.00 | 0.00 | 9920.77 | 0.00 |
September | 56669.24 | 01-SEP-14:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3210.80 | 0.00 | 0.00 | 6363.47 | 0.00 |
October | 50901.79 | 31-OCT-12:50 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 52954.78 | 30-NOV-16:30 | 31277.33 | 10112.62 | 6311.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 52960.96 | 30-DEC-16:00 | 31277.33 | 10112.62 | 6311.00 | 0.00 | 3627.78 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 50901.79 | 31277.33 | 10112.62 | 0.00 | 0.00 | 3210.80 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 67276.17 | 35189.04 | 10112.62 | 6311.00 | 0.00 | 5516.10 | 0.00 | 0.00 | 14645.51 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 355658.97 | 03-JAN-17:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 353880.62 | 01-FEB-06:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 313059.54 | 15-MAR-05:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 184218.03 | 04-APR-18:30 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 60741.52 | 01-MAY-05:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 8278.04 | 02-JUN-06:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 2987.48 | 18-AUG-06:30 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 24896.64 | 28-SEP-06:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 113654.22 | 30-OCT-06:00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 246255.81 | 25-NOV-02:09 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 355658.97 | 18-DEC-17:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 355658.97 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 76.17 | 16.50 | 32.67 | 18.85 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 47.33 | 16.81 | 21.67 | 19.08 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 22.67 | 17.68 | 15.17 | 19.03 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 8.83 | 19.13 | 8.17 | 19.47 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 3.00 | 19.84 | 2.83 | 20.13 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.17 | 20.50 | 0.17 | 20.50 | 0.50 | 24.87 | 0.50 | 24.87 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 24.56 | 1.67 | 24.56 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 24.56 | 0.33 | 24.56 |
September | 1.00 | 20.41 | 1.00 | 20.41 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6.17 | 20.00 | 6.17 | 20.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 10.50 | 18.75 | 9.00 | 19.37 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 63.17 | 16.33 | 22.67 | 19.09 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 239.00 | 16.98 | 119.50 | 19.15 | 2.50 | 24.62 | 2.50 | 24.62 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 76.17 | 20.50 | 32.67 | 20.50 | 1.67 | 24.87 | 1.67 | 24.87 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 224.17 | 13.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 145.17 | 13.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 107.67 | 14.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 67.33 | 14.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2.33 | 14.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.40 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 27.40 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 48.17 | 14.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 107.50 | 14.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 204.83 | 13.14 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 907.17 | 13.63 | 0.00 | 3.83 | 27.40 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 224.17 | 14.83 | 0.00 | 0.00 | 2.67 | 27.40 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 30.50 | 8.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3.67 | 8.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 13.50 | 8.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 47.67 | 8.35 | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 30.50 | 8.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 20.84 | 300.00 | 20.84 | 300.00 | 20.84 |
February | 276.00 | 20.93 | 276.00 | 20.93 | 276.00 | 20.93 |
March | 324.00 | 21.00 | 324.00 | 21.00 | 324.00 | 21.00 |
April | 300.00 | 21.18 | 285.33 | 21.10 | 285.33 | 21.10 |
May | 274.00 | 22.44 | 115.00 | 21.43 | 104.50 | 21.18 |
June | 185.33 | 23.37 | 108.17 | 23.74 | 15.00 | 22.76 |
July | 15.33 | 23.58 | 244.33 | 23.91 | 5.50 | 24.01 |
August | 57.17 | 23.33 | 188.83 | 23.90 | 1.83 | 23.97 |
September | 268.67 | 22.63 | 73.00 | 21.86 | 55.00 | 21.19 |
October | 300.00 | 21.28 | 259.17 | 21.09 | 259.17 | 21.09 |
November | 288.00 | 21.05 | 284.67 | 21.04 | 284.67 | 21.04 |
December | 300.00 | 20.94 | 300.00 | 20.94 | 300.00 | 20.94 |
Annual Sum or Average | 2888.50 | 21.52 | 2758.50 | 21.60 | 2211.00 | 21.03 |
Minimum of Months | 15.33 | 20.84 | 73.00 | 20.84 | 1.83 | 20.84 |
Maximum of Months | 324.00 | 23.58 | 324.00 | 23.91 | 324.00 | 24.01 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | ||
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
May | 0.145867E+10 | 0.354626E+09 | 117.47 | 0.131234E+10 | 0.146329E+09 | 0.00 | 0.78 | 26-MAY-05:03 | 0.00 | 01-MAY-00:10 | 12880.50 | 26-MAY-05:03 | 10533.48 | 26-MAY-05:03 | 2347.02 | 26-MAY-05:03 | 2913.84 | 26-MAY-05:03 | 0.00 | 01-MAY-00:10 |
June | 0.447704E+10 | 0.107330E+10 | 240.33 | 0.361389E+10 | 0.863149E+09 | 0.00 | 1.00 | 26-JUN-05:02 | 0.00 | 01-JUN-00:10 | 21176.57 | 30-JUN-05:01 | 14593.82 | 27-JUN-05:02 | 9545.86 | 30-JUN-05:07 | 4356.19 | 30-JUN-05:01 | 0.00 | 01-JUN-00:10 |
July | 0.715793E+10 | 0.168552E+10 | 274.39 | 0.578135E+10 | 0.137658E+10 | 0.00 | 1.00 | 01-JUL-05:01 | 0.00 | 01-JUL-00:10 | 20381.25 | 05-JUL-05:01 | 16796.46 | 08-JUL-05:02 | 8289.92 | 05-JUL-05:05 | 4162.74 | 05-JUL-05:01 | 0.00 | 01-JUL-00:10 |
August | 0.584660E+10 | 0.137405E+10 | 273.68 | 0.467683E+10 | 0.116977E+10 | 0.00 | 1.00 | 01-AUG-05:02 | 0.00 | 01-AUG-00:10 | 19735.82 | 09-AUG-05:02 | 16097.39 | 14-AUG-05:02 | 6970.03 | 09-AUG-05:03 | 4071.72 | 09-AUG-05:02 | 0.00 | 01-AUG-00:10 |
September | 0.130637E+10 | 0.311930E+09 | 121.68 | 0.117593E+10 | 0.130442E+09 | 0.00 | 1.00 | 01-SEP-05:02 | 0.00 | 01-SEP-00:10 | 19759.76 | 01-SEP-05:02 | 15582.18 | 02-SEP-05:02 | 7440.89 | 01-SEP-05:03 | 4075.22 | 01-SEP-05:02 | 0.00 | 01-SEP-00:10 |
October | 17832102.47 | 4400908.97 | 6.00 | 17783056.08 | 49046.38 | 0.00 | 0.12 | 19-OCT-15:40 | 0.00 | 01-OCT-00:10 | 1749.68 | 19-OCT-15:40 | 1734.57 | 19-OCT-15:40 | 15.11 | 19-OCT-15:40 | 428.32 | 19-OCT-15:40 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 |
Annual Sum or Average | 0.202644E+11 | 0.480383E+10 | 1033.55 | 0.165781E+11 | 0.368632E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.715793E+10 | 0.168552E+10 | 274.39 | 0.578135E+10 | 0.137658E+10 | 0.00 | 1.00 | 0.00 | 21176.57 | 16796.46 | 9545.86 | 4356.19 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 | 0.00 | 01-FEB-00:05 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
May | 0.345966E+09 | 0.105040E+09 | 23.50 | 0.281646E+09 | 64320030.60 | 0.00 | 0.28 | 25-MAY-15:10 | 0.00 | 01-MAY-00:10 | 11203.32 | 25-MAY-15:10 | 8696.21 | 25-MAY-15:10 | 2507.10 | 25-MAY-15:10 | 3400.45 | 25-MAY-15:10 | 0.00 | 01-MAY-00:10 |
June | 0.460644E+10 | 0.133744E+10 | 83.27 | 0.322215E+10 | 0.138429E+10 | 0.00 | 1.00 | 28-JUN-17:10 | 0.00 | 01-JUN-00:10 | 48547.98 | 29-JUN-18:23 | 35268.77 | 30-JUN-18:23 | 16377.37 | 29-JUN-18:23 | 13521.53 | 29-JUN-17:08 | 0.00 | 01-JUN-00:10 |
July | 0.905041E+10 | 0.258802E+10 | 196.66 | 0.643244E+10 | 0.261797E+10 | 0.00 | 1.00 | 03-JUL-17:10 | 0.00 | 01-JUL-00:10 | 51561.63 | 23-JUL-11:05 | 37865.98 | 24-JUL-17:08 | 22902.01 | 23-JUL-10:25 | 13140.98 | 23-JUL-11:05 | 0.00 | 01-JUL-00:10 |
August | 0.363192E+10 | 0.103855E+10 | 106.83 | 0.256373E+10 | 0.106820E+10 | 0.00 | 1.00 | 08-AUG-17:12 | 0.00 | 01-AUG-00:10 | 50194.91 | 08-AUG-17:12 | 30536.17 | 08-AUG-17:12 | 19658.74 | 08-AUG-17:12 | 13067.99 | 08-AUG-17:12 | 0.00 | 01-AUG-00:10 |
September | 0.310600E+09 | 88281503.30 | 8.83 | 0.237123E+09 | 73477659.73 | 0.00 | 0.36 | 01-SEP-15:00 | 0.00 | 01-SEP-00:10 | 14789.67 | 01-SEP-15:00 | 12020.85 | 01-SEP-15:00 | 3385.84 | 01-SEP-12:30 | 4248.45 | 01-SEP-15:00 | 0.00 | 01-SEP-00:10 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 | 0.00 | 01-DEC-00:02 |
Annual Sum or Average | 0.179453E+11 | 0.515734E+10 | 419.09 | 0.127371E+11 | 0.520826E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.905041E+10 | 0.258802E+10 | 196.66 | 0.643244E+10 | 0.261797E+10 | 0.00 | 1.00 | 0.00 | 51561.63 | 37865.98 | 22902.01 | 13521.53 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 73.54 | 31.01 | 42.53 | 20.69 | 307.05 | 0.00 | 0.00 | 744.00 |
February | 118.89 | 54.34 | 64.56 | 61.66 | 240.52 | 0.00 | 0.00 | 672.00 |
March | 156.45 | 80.20 | 76.25 | 108.22 | 181.29 | 0.00 | 0.00 | 744.00 |
April | 199.37 | 100.97 | 98.40 | 176.52 | 101.32 | 0.00 | 0.00 | 720.00 |
May | 245.44 | 117.24 | 128.19 | 256.28 | 58.24 | 0.00 | 0.00 | 744.00 |
June | 236.47 | 102.28 | 134.19 | 255.17 | 46.19 | 0.00 | 0.00 | 720.00 |
July | 252.93 | 117.86 | 135.07 | 274.54 | 52.34 | 0.00 | 0.00 | 744.00 |
August | 207.16 | 93.81 | 113.35 | 216.62 | 58.20 | 0.00 | 0.00 | 744.00 |
September | 162.30 | 72.79 | 89.51 | 152.11 | 75.99 | 0.00 | 0.00 | 720.00 |
October | 102.68 | 41.25 | 61.43 | 73.77 | 105.24 | 0.00 | 0.00 | 744.00 |
November | 62.65 | 21.35 | 41.30 | 24.12 | 172.44 | 0.00 | 0.00 | 720.00 |
December | 55.33 | 19.25 | 36.08 | 9.87 | 296.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 156.31 | 71.13 | 85.18 | 136.23 | 140.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 55.33 | 19.25 | 36.08 | 9.87 | 46.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 252.93 | 117.86 | 135.07 | 274.54 | 307.05 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 73.54 | 31.01 | 42.53 | 20.69 | 307.05 | 0.00 | 0.00 | 744.00 |
February | 118.89 | 54.34 | 64.56 | 61.66 | 240.52 | 0.00 | 0.00 | 672.00 |
March | 156.45 | 80.20 | 76.25 | 108.22 | 181.29 | 0.00 | 0.00 | 744.00 |
April | 199.37 | 100.97 | 98.40 | 176.52 | 101.32 | 0.00 | 0.00 | 720.00 |
May | 245.44 | 117.24 | 128.19 | 256.28 | 58.24 | 0.00 | 0.00 | 744.00 |
June | 236.47 | 102.28 | 134.19 | 255.17 | 46.19 | 0.00 | 0.00 | 720.00 |
July | 252.93 | 117.86 | 135.07 | 274.54 | 52.34 | 0.00 | 0.00 | 744.00 |
August | 207.16 | 93.81 | 113.35 | 216.62 | 58.20 | 0.00 | 0.00 | 744.00 |
September | 162.30 | 72.79 | 89.51 | 152.11 | 75.99 | 0.00 | 0.00 | 720.00 |
October | 102.68 | 41.25 | 61.43 | 73.77 | 105.24 | 0.00 | 0.00 | 744.00 |
November | 62.65 | 21.35 | 41.30 | 24.12 | 172.44 | 0.00 | 0.00 | 720.00 |
December | 55.33 | 19.25 | 36.08 | 9.87 | 296.51 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 156.31 | 71.13 | 85.18 | 136.23 | 140.93 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 55.33 | 19.25 | 36.08 | 9.87 | 46.19 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 252.93 | 117.86 | 135.07 | 274.54 | 307.05 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.16 | 0.00 | 19.16 | 0.06 | 194.78 | 0.00 | 0.00 | 744.00 |
February | 29.43 | 0.00 | 29.43 | 1.25 | 153.51 | 0.00 | 0.00 | 672.00 |
March | 36.22 | 0.00 | 36.22 | 3.47 | 114.69 | 0.00 | 0.00 | 744.00 |
April | 47.57 | 0.46 | 47.11 | 19.68 | 61.33 | 0.00 | 0.00 | 720.00 |
May | 66.82 | 3.59 | 63.23 | 50.11 | 32.55 | 0.00 | 0.00 | 744.00 |
June | 74.47 | 8.14 | 66.33 | 64.81 | 25.30 | 0.00 | 0.00 | 720.00 |
July | 71.08 | 6.00 | 65.08 | 60.91 | 28.62 | 0.00 | 0.00 | 744.00 |
August | 54.25 | 1.09 | 53.16 | 43.09 | 33.43 | 0.00 | 0.00 | 744.00 |
September | 42.17 | 0.03 | 42.14 | 25.33 | 45.51 | 0.00 | 0.00 | 720.00 |
October | 29.25 | 0.00 | 29.25 | 8.42 | 63.89 | 0.00 | 0.00 | 744.00 |
November | 19.37 | 0.00 | 19.37 | 1.17 | 107.62 | 0.00 | 0.00 | 720.00 |
December | 16.23 | 0.00 | 16.23 | 0.00 | 185.71 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 42.23 | 1.62 | 40.62 | 23.32 | 87.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 16.23 | 0.00 | 16.23 | 0.00 | 25.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 74.47 | 8.14 | 66.33 | 64.81 | 194.78 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 19.16 | 0.00 | 19.16 | 0.06 | 194.78 | 0.00 | 0.00 | 744.00 |
February | 29.43 | 0.00 | 29.43 | 1.25 | 153.52 | 0.00 | 0.00 | 672.00 |
March | 36.22 | 0.00 | 36.22 | 3.47 | 114.69 | 0.00 | 0.00 | 744.00 |
April | 47.57 | 0.46 | 47.11 | 19.68 | 61.33 | 0.00 | 0.00 | 720.00 |
May | 66.82 | 3.59 | 63.23 | 50.11 | 32.55 | 0.00 | 0.00 | 744.00 |
June | 74.47 | 8.14 | 66.33 | 64.81 | 25.30 | 0.00 | 0.00 | 720.00 |
July | 71.08 | 6.00 | 65.08 | 60.91 | 28.62 | 0.00 | 0.00 | 744.00 |
August | 54.25 | 1.09 | 53.15 | 43.09 | 33.43 | 0.00 | 0.00 | 744.00 |
September | 42.17 | 0.03 | 42.14 | 25.33 | 45.51 | 0.00 | 0.00 | 720.00 |
October | 29.25 | 0.00 | 29.25 | 8.42 | 63.89 | 0.00 | 0.00 | 744.00 |
November | 19.37 | 0.00 | 19.37 | 1.17 | 107.62 | 0.00 | 0.00 | 720.00 |
December | 16.23 | 0.00 | 16.23 | 0.00 | 185.71 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 42.23 | 1.62 | 40.61 | 23.32 | 87.00 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 16.23 | 0.00 | 16.23 | 0.00 | 25.30 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 74.47 | 8.14 | 66.33 | 64.81 | 194.78 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.32 | 5.67 | 12.65 | 1.29 | 101.53 | 0.00 | 0.00 | 744.00 |
February | 33.03 | 14.43 | 18.59 | 11.38 | 76.36 | 0.00 | 0.00 | 672.00 |
March | 48.86 | 27.30 | 21.56 | 34.03 | 54.52 | 0.00 | 0.00 | 744.00 |
April | 72.41 | 45.63 | 26.78 | 71.66 | 31.22 | 0.00 | 0.00 | 720.00 |
May | 89.30 | 50.40 | 38.90 | 97.82 | 21.67 | 0.00 | 0.00 | 744.00 |
June | 94.44 | 54.75 | 39.69 | 102.81 | 21.00 | 1.17 | 0.00 | 720.00 |
July | 96.54 | 57.87 | 38.67 | 100.26 | 28.38 | 0.00 | 0.00 | 744.00 |
August | 76.69 | 43.46 | 33.24 | 78.08 | 26.74 | 0.00 | 0.00 | 744.00 |
September | 55.14 | 28.42 | 26.72 | 50.93 | 30.25 | 1.33 | 0.00 | 720.00 |
October | 31.05 | 11.38 | 19.67 | 22.61 | 31.36 | 9.17 | 0.00 | 744.00 |
November | 18.24 | 5.06 | 13.19 | 5.57 | 49.86 | 10.50 | 0.00 | 720.00 |
December | 14.33 | 3.08 | 11.25 | 0.57 | 95.04 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 54.14 | 29.02 | 25.11 | 48.28 | 47.24 | 22.17 | 0.00 | 8760.00 |
Minimum of Months | 14.33 | 3.08 | 11.25 | 0.57 | 21.00 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 96.54 | 57.87 | 39.69 | 102.81 | 101.53 | 10.50 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.196982E+09 | 83064779.19 | 0.113918E+09 | 55424088.35 | 0.822396E+09 |
February | 0.287631E+09 | 0.131452E+09 | 0.156179E+09 | 0.149156E+09 | 0.581875E+09 |
March | 0.419027E+09 | 0.214795E+09 | 0.204232E+09 | 0.289859E+09 | 0.485555E+09 |
April | 0.516759E+09 | 0.261702E+09 | 0.255057E+09 | 0.457549E+09 | 0.262621E+09 |
May | 0.657380E+09 | 0.314025E+09 | 0.343355E+09 | 0.686424E+09 | 0.155981E+09 |
June | 0.612921E+09 | 0.265103E+09 | 0.347818E+09 | 0.661412E+09 | 0.119727E+09 |
July | 0.677437E+09 | 0.315669E+09 | 0.361768E+09 | 0.735322E+09 | 0.140195E+09 |
August | 0.554860E+09 | 0.251252E+09 | 0.303608E+09 | 0.580208E+09 | 0.155880E+09 |
September | 0.420675E+09 | 0.188670E+09 | 0.232005E+09 | 0.394280E+09 | 0.196976E+09 |
October | 0.275020E+09 | 0.110496E+09 | 0.164524E+09 | 0.197586E+09 | 0.281883E+09 |
November | 0.162384E+09 | 55330218.03 | 0.107054E+09 | 62522946.62 | 0.446975E+09 |
December | 0.148194E+09 | 51560152.96 | 96633727.19 | 26437494.53 | 0.794182E+09 |
Annual Sum or Average | 0.492927E+10 | 0.224312E+10 | 0.268615E+10 | 0.429618E+10 | 0.444425E+10 |
Minimum of Months | 0.148194E+09 | 51560152.96 | 96633727.19 | 26437494.53 | 0.119727E+09 |
Maximum of Months | 0.677437E+09 | 0.315669E+09 | 0.361768E+09 | 0.735322E+09 | 0.822396E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.196982E+09 | 83064779.19 | 0.113918E+09 | 55424088.35 | 0.822396E+09 |
February | 0.287631E+09 | 0.131452E+09 | 0.156179E+09 | 0.149156E+09 | 0.581875E+09 |
March | 0.419027E+09 | 0.214795E+09 | 0.204232E+09 | 0.289859E+09 | 0.485555E+09 |
April | 0.516759E+09 | 0.261702E+09 | 0.255057E+09 | 0.457549E+09 | 0.262621E+09 |
May | 0.657380E+09 | 0.314025E+09 | 0.343355E+09 | 0.686424E+09 | 0.155981E+09 |
June | 0.612921E+09 | 0.265103E+09 | 0.347818E+09 | 0.661412E+09 | 0.119727E+09 |
July | 0.677437E+09 | 0.315669E+09 | 0.361768E+09 | 0.735322E+09 | 0.140195E+09 |
August | 0.554860E+09 | 0.251252E+09 | 0.303608E+09 | 0.580208E+09 | 0.155880E+09 |
September | 0.420675E+09 | 0.188670E+09 | 0.232005E+09 | 0.394280E+09 | 0.196976E+09 |
October | 0.275020E+09 | 0.110496E+09 | 0.164524E+09 | 0.197586E+09 | 0.281883E+09 |
November | 0.162384E+09 | 55330218.03 | 0.107054E+09 | 62522946.62 | 0.446975E+09 |
December | 0.148194E+09 | 51560152.96 | 96633727.19 | 26437494.53 | 0.794182E+09 |
Annual Sum or Average | 0.492927E+10 | 0.224312E+10 | 0.268615E+10 | 0.429618E+10 | 0.444425E+10 |
Minimum of Months | 0.148194E+09 | 51560152.96 | 96633727.19 | 26437494.53 | 0.119727E+09 |
Maximum of Months | 0.677437E+09 | 0.315669E+09 | 0.361768E+09 | 0.735322E+09 | 0.822396E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 51321087.92 | 0.00 | 51321087.92 | 172609.75 | 0.521687E+09 |
February | 71204182.79 | 0.00 | 71204182.79 | 3023128.00 | 0.371383E+09 |
March | 97016096.23 | 6666.66 | 97009429.57 | 9281889.11 | 0.307175E+09 |
April | 0.123309E+09 | 1199240.75 | 0.122110E+09 | 51004857.54 | 0.158972E+09 |
May | 0.178969E+09 | 9617355.26 | 0.169352E+09 | 0.134212E+09 | 87190563.30 |
June | 0.193036E+09 | 21099889.06 | 0.171936E+09 | 0.167994E+09 | 65574381.42 |
July | 0.190386E+09 | 16074186.04 | 0.174312E+09 | 0.163150E+09 | 76652619.49 |
August | 0.145299E+09 | 2924583.83 | 0.142375E+09 | 0.115408E+09 | 89545995.90 |
September | 0.109298E+09 | 76927.55 | 0.109222E+09 | 65652164.14 | 0.117953E+09 |
October | 78342328.43 | 0.00 | 78342328.43 | 22559447.85 | 0.171134E+09 |
November | 50199242.31 | 0.00 | 50199242.31 | 3020498.99 | 0.278959E+09 |
December | 43483305.84 | 0.00 | 43483305.84 | 0.00 | 0.497418E+09 |
Annual Sum or Average | 0.133186E+10 | 50998849.14 | 0.128087E+10 | 0.735479E+09 | 0.274365E+10 |
Minimum of Months | 43483305.84 | 0.00 | 43483305.84 | 0.00 | 65574381.42 |
Maximum of Months | 0.193036E+09 | 21099889.06 | 0.174312E+09 | 0.167994E+09 | 0.521687E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 51319393.41 | 0.00 | 51319393.41 | 172568.77 | 0.521688E+09 |
February | 71201942.39 | 0.00 | 71201942.39 | 3022744.40 | 0.371384E+09 |
March | 97013172.57 | 6666.35 | 97006506.23 | 9280988.08 | 0.307176E+09 |
April | 0.123305E+09 | 1199184.54 | 0.122106E+09 | 51002366.24 | 0.158972E+09 |
May | 0.178964E+09 | 9616904.48 | 0.169347E+09 | 0.134207E+09 | 87190320.25 |
June | 0.193029E+09 | 21098900.08 | 0.171930E+09 | 0.167987E+09 | 65573975.80 |
July | 0.190380E+09 | 16073432.62 | 0.174307E+09 | 0.163145E+09 | 76652139.95 |
August | 0.145295E+09 | 2924446.75 | 0.142370E+09 | 0.115404E+09 | 89545733.31 |
September | 0.109295E+09 | 76923.94 | 0.109218E+09 | 65649032.86 | 0.117953E+09 |
October | 78339715.69 | 0.00 | 78339715.69 | 22557698.10 | 0.171135E+09 |
November | 50197531.95 | 0.00 | 50197531.95 | 3020227.49 | 0.278960E+09 |
December | 43481822.99 | 0.00 | 43481822.99 | 0.00 | 0.497419E+09 |
Annual Sum or Average | 0.133182E+10 | 50996458.76 | 0.128083E+10 | 0.735448E+09 | 0.274365E+10 |
Minimum of Months | 43481822.99 | 0.00 | 43481822.99 | 0.00 | 65573975.80 |
Maximum of Months | 0.193029E+09 | 21098900.08 | 0.174307E+09 | 0.167987E+09 | 0.521688E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 49058899.47 | 15184144.64 | 33874754.83 | 3459773.44 | 0.271930E+09 |
February | 79899943.63 | 34916729.97 | 44983213.65 | 27518509.92 | 0.184721E+09 |
March | 0.130864E+09 | 73123840.44 | 57739741.75 | 91155535.64 | 0.146033E+09 |
April | 0.187676E+09 | 0.118267E+09 | 69409424.78 | 0.185747E+09 | 80913327.79 |
May | 0.239184E+09 | 0.134998E+09 | 0.104186E+09 | 0.261998E+09 | 58028773.54 |
June | 0.244791E+09 | 0.141912E+09 | 0.102879E+09 | 0.266474E+09 | 54431542.30 |
July | 0.258567E+09 | 0.154990E+09 | 0.103577E+09 | 0.268538E+09 | 76008207.33 |
August | 0.205419E+09 | 0.116394E+09 | 89024783.69 | 0.209128E+09 | 71621500.39 |
September | 0.142922E+09 | 73656383.10 | 69265250.27 | 0.132013E+09 | 78403979.28 |
October | 83176287.67 | 30481534.25 | 52694753.42 | 60552293.06 | 83992468.08 |
November | 47284480.14 | 13103125.61 | 34181354.53 | 14430915.35 | 0.129233E+09 |
December | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 0.254561E+09 |
Annual Sum or Average | 0.170721E+10 | 0.915267E+09 | 0.791946E+09 | 0.152255E+10 | 0.148988E+10 |
Minimum of Months | 38371420.35 | 8240829.99 | 30130590.36 | 1535308.63 | 54431542.30 |
Maximum of Months | 0.258567E+09 | 0.154990E+09 | 0.104186E+09 | 0.268538E+09 | 0.271930E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 24.59 | 986.72 | 185.41 | 62.03 | 123.39 | 0.00 | 0.00 |
February | 108.16 | 770.42 | 296.65 | 108.67 | 187.98 | 0.00 | 0.00 |
March | 209.44 | 578.01 | 385.34 | 160.40 | 224.94 | 0.00 | 0.00 |
April | 388.43 | 321.33 | 493.88 | 202.86 | 291.02 | 0.00 | 0.00 |
May | 612.08 | 180.88 | 624.51 | 241.67 | 382.84 | 0.00 | 0.00 |
June | 636.65 | 139.66 | 621.88 | 220.84 | 401.04 | 0.00 | 0.00 |
July | 667.83 | 158.85 | 648.01 | 247.72 | 400.30 | 0.00 | 0.00 |
August | 518.98 | 182.82 | 522.82 | 189.80 | 333.02 | 0.00 | 0.00 |
September | 352.96 | 241.07 | 408.93 | 145.64 | 263.29 | 0.00 | 0.00 |
October | 161.21 | 335.10 | 263.86 | 82.51 | 181.35 | 0.00 | 0.00 |
November | 42.34 | 551.90 | 164.03 | 42.69 | 121.34 | 0.00 | 0.00 |
December | 8.99 | 953.70 | 143.13 | 38.50 | 104.63 | 0.00 | 0.00 |
Annual Sum or Average | 312.15 | 448.90 | 397.08 | 145.49 | 251.59 | 0.00 | 0.00 |
Minimum of Months | 8.99 | 139.66 | 143.13 | 38.50 | 104.63 | 0.00 | 0.00 |
Maximum of Months | 667.83 | 986.72 | 648.01 | 247.72 | 401.04 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 12.92 | 1015.27 | 183.16 | 56.69 | 126.47 | 0.00 | 0.00 |
February | 113.75 | 763.56 | 330.27 | 144.33 | 185.94 | 0.00 | 0.00 |
March | 340.34 | 545.23 | 488.59 | 273.01 | 215.58 | 0.00 | 0.00 |
April | 716.62 | 312.17 | 724.06 | 456.28 | 267.78 | 0.00 | 0.00 |
May | 978.19 | 216.65 | 893.01 | 504.02 | 388.99 | 0.00 | 0.00 |
June | 1028.07 | 210.00 | 944.41 | 547.50 | 396.91 | 0.00 | 0.00 |
July | 1002.61 | 283.78 | 965.38 | 578.66 | 386.71 | 0.00 | 0.00 |
August | 780.80 | 267.40 | 766.95 | 434.57 | 332.38 | 0.00 | 0.00 |
September | 509.31 | 302.48 | 551.40 | 284.17 | 267.23 | 0.00 | 0.00 |
October | 226.08 | 313.59 | 310.54 | 113.81 | 196.74 | 0.00 | 0.00 |
November | 55.67 | 498.58 | 182.42 | 50.55 | 131.87 | 0.00 | 0.00 |
December | 5.73 | 950.42 | 143.26 | 30.77 | 112.49 | 0.00 | 0.00 |
Annual Sum or Average | 482.80 | 472.44 | 541.35 | 290.23 | 251.12 | 0.00 | 0.00 |
Minimum of Months | 5.73 | 210.00 | 143.26 | 30.77 | 112.49 | 0.00 | 0.00 |
Maximum of Months | 1028.07 | 1015.27 | 965.38 | 578.66 | 396.91 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 65864131.66 | 0.264284E+10 | 0.496605E+09 | 0.166130E+09 | 0.330476E+09 | 0.00 | 0.00 |
February | 0.261654E+09 | 0.186381E+10 | 0.717668E+09 | 0.262903E+09 | 0.454764E+09 | 0.00 | 0.00 |
March | 0.560964E+09 | 0.154814E+10 | 0.103208E+10 | 0.429603E+09 | 0.602480E+09 | 0.00 | 0.00 |
April | 0.100682E+10 | 0.832899E+09 | 0.128013E+10 | 0.525803E+09 | 0.754331E+09 | 0.00 | 0.00 |
May | 0.163938E+10 | 0.484457E+09 | 0.167269E+10 | 0.647284E+09 | 0.102541E+10 | 0.00 | 0.00 |
June | 0.165020E+10 | 0.361999E+09 | 0.161191E+10 | 0.572405E+09 | 0.103950E+10 | 0.00 | 0.00 |
July | 0.178872E+10 | 0.425472E+09 | 0.173564E+10 | 0.663485E+09 | 0.107216E+10 | 0.00 | 0.00 |
August | 0.139003E+10 | 0.489653E+09 | 0.140031E+10 | 0.508354E+09 | 0.891961E+09 | 0.00 | 0.00 |
September | 0.914865E+09 | 0.624863E+09 | 0.105994E+10 | 0.377493E+09 | 0.682451E+09 | 0.00 | 0.00 |
October | 0.431793E+09 | 0.897539E+09 | 0.706722E+09 | 0.220992E+09 | 0.485730E+09 | 0.00 | 0.00 |
November | 0.109736E+09 | 0.143052E+10 | 0.425165E+09 | 0.110660E+09 | 0.314504E+09 | 0.00 | 0.00 |
December | 24071784.23 | 0.255440E+10 | 0.383353E+09 | 0.103120E+09 | 0.280233E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.984409E+10 | 0.141566E+11 | 0.125222E+11 | 0.458823E+10 | 0.793400E+10 | 0.00 | 0.00 |
Minimum of Months | 24071784.23 | 0.361999E+09 | 0.383353E+09 | 0.103120E+09 | 0.280233E+09 | 0.00 | 0.00 |
Maximum of Months | 0.178872E+10 | 0.264284E+10 | 0.173564E+10 | 0.663485E+09 | 0.107216E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 34597734.37 | 0.271930E+10 | 0.490589E+09 | 0.151841E+09 | 0.338748E+09 | 0.00 | 0.00 |
February | 0.275185E+09 | 0.184721E+10 | 0.798999E+09 | 0.349167E+09 | 0.449832E+09 | 0.00 | 0.00 |
March | 0.911555E+09 | 0.146033E+10 | 0.130864E+10 | 0.731238E+09 | 0.577397E+09 | 0.00 | 0.00 |
April | 0.185747E+10 | 0.809133E+09 | 0.187676E+10 | 0.118267E+10 | 0.694094E+09 | 0.00 | 0.00 |
May | 0.261998E+10 | 0.580287E+09 | 0.239184E+10 | 0.134998E+10 | 0.104186E+10 | 0.00 | 0.00 |
June | 0.266474E+10 | 0.544315E+09 | 0.244791E+10 | 0.141912E+10 | 0.102879E+10 | 0.00 | 0.00 |
July | 0.268538E+10 | 0.760081E+09 | 0.258567E+10 | 0.154990E+10 | 0.103577E+10 | 0.00 | 0.00 |
August | 0.209128E+10 | 0.716215E+09 | 0.205419E+10 | 0.116394E+10 | 0.890248E+09 | 0.00 | 0.00 |
September | 0.132013E+10 | 0.784040E+09 | 0.142922E+10 | 0.736564E+09 | 0.692653E+09 | 0.00 | 0.00 |
October | 0.605522E+09 | 0.839925E+09 | 0.831763E+09 | 0.304815E+09 | 0.526948E+09 | 0.00 | 0.00 |
November | 0.144308E+09 | 0.129233E+10 | 0.472845E+09 | 0.131031E+09 | 0.341814E+09 | 0.00 | 0.00 |
December | 15353086.32 | 0.254561E+10 | 0.383714E+09 | 82408299.94 | 0.301306E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.152255E+11 | 0.148988E+11 | 0.170721E+11 | 0.915267E+10 | 0.791946E+10 | 0.00 | 0.00 |
Minimum of Months | 15353086.32 | 0.544315E+09 | 0.383714E+09 | 82408299.94 | 0.301306E+09 | 0.00 | 0.00 |
Maximum of Months | 0.268538E+10 | 0.271930E+10 | 0.258567E+10 | 0.154990E+10 | 0.104186E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | -16.9 | -17.3 | -20.0 | 3.73 | -31.9 | 33.25 | 98.18 | 0.00 |
February | -11.6 | -12.6 | -16.7 | 4.33 | -26.7 | 48.91 | 138.70 | 0.00 |
March | -6.2 | -7.5 | -10.8 | 3.55 | -19.4 | 56.69 | 163.76 | 0.01 |
April | 3.97 | 0.48 | -4.8 | 4.72 | -9.1 | 70.41 | 207.70 | 0.01 |
May | 13.43 | 8.45 | 3.53 | 3.60 | 2.20 | 102.27 | 202.62 | 0.00 |
June | 18.03 | 14.18 | 11.55 | 3.74 | 7.84 | 104.36 | 210.60 | 0.06 |
July | 19.67 | 16.51 | 14.78 | 3.14 | 8.96 | 101.67 | 223.82 | 0.04 |
August | 17.94 | 15.19 | 13.59 | 3.45 | 8.98 | 87.39 | 175.79 | 0.04 |
September | 12.29 | 9.87 | 7.80 | 3.78 | 3.33 | 70.27 | 143.96 | 0.00 |
October | 5.42 | 3.48 | 1.07 | 3.53 | -4.7 | 51.74 | 90.11 | 0.00 |
November | -2.0 | -3.6 | -6.9 | 4.42 | -13.7 | 34.68 | 65.95 | 0.00 |
December | -14.6 | -15.1 | -18.1 | 3.91 | -28.3 | 29.58 | 68.99 | 0.00 |
Annual Sum or Average | 3.36 | 1.07 | -2.0 | 3.82 | -8.5 | 66.03 | 149.18 | 0.01 |
Minimum of Months | -16.9 | -17.3 | -20.0 | 3.14 | -31.9 | 29.58 | 65.95 | 0.00 |
Maximum of Months | 19.67 | 16.51 | 14.78 | 4.72 | 8.98 | 104.36 | 223.82 | 0.06 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.10 | 29-JAN-14:00 | -0.9 | -4.4 | 2.60 | -11.4 | 145.00 | 110.00 |
February | 8.90 | 20-FEB-15:00 | 2.85 | -6.7 | 8.80 | -9.0 | 49.00 | 646.00 |
March | 11.10 | 26-MAR-15:00 | 5.46 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 26.70 | 23-APR-15:00 | 16.93 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 29.40 | 25-MAY-17:00 | 19.24 | 13.90 | 1.50 | 16.49 | 47.50 | 582.00 |
June | 35.00 | 29-JUN-15:00 | 24.70 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 31.10 | 15-JUL-14:20 | 25.34 | 23.33 | 8.07 | 19.92 | 299.67 | 518.33 |
August | 30.60 | 08-AUG-14:00 | 23.35 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 26.10 | 01-SEP-14:00 | 17.80 | 13.30 | 3.60 | 14.28 | 112.00 | 751.50 |
October | 22.20 | 19-OCT-14:00 | 13.60 | 7.20 | 6.70 | 8.15 | 35.50 | 701.50 |
November | 18.30 | 01-NOV-14:00 | 13.43 | 10.00 | 3.10 | 11.84 | 105.00 | 30.50 |
December | 1.10 | 28-DEC-02:00 | 0.43 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.10 | -0.9 | -6.7 | 1.50 | -11.4 | 0.00 | 0.00 | |
Maximum of Months | 35.00 | 25.34 | 23.33 | 11.30 | 24.66 | 299.67 | 842.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -35.6 | 06-JAN-08:00 | -35.7 | -37.8 | 0.00 | -57.8 | 27.00 | 381.00 |
February | -33.3 | 14-FEB-06:00 | -33.4 | -36.7 | 0.00 | -55.6 | 0.00 | 0.00 |
March | -28.9 | 05-MAR-06:00 | -29.1 | -32.2 | 1.50 | -50.6 | 27.00 | 41.50 |
April | -13.9 | 05-APR-05:00 | -14.3 | -16.1 | 0.00 | -32.5 | 14.50 | 199.00 |
May | -3.9 | 01-MAY-05:00 | -6.0 | -12.2 | 0.00 | -22.4 | 35.00 | 415.00 |
June | 1.10 | 04-JUN-04:00 | 0.61 | 0.00 | 0.00 | -14.9 | 37.00 | 169.50 |
July | 6.10 | 02-JUL-04:00 | 6.10 | 6.10 | 0.00 | -8.8 | 33.50 | 204.50 |
August | 4.40 | 19-AUG-03:00 | 4.40 | 4.40 | 0.00 | -10.7 | 0.00 | 0.00 |
September | 1.10 | 06-SEP-03:00 | 1.10 | 1.10 | 0.00 | -14.7 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.6 | -12.8 | 1.50 | -28.2 | 0.00 | 0.00 |
November | -20.6 | 29-NOV-05:00 | -20.8 | -22.2 | 2.10 | -37.8 | 0.00 | 0.00 |
December | -31.1 | 24-DEC-06:19 | -31.3 | -35.1 | 3.33 | -53.1 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -35.6 | -35.7 | -37.8 | 0.00 | -57.8 | 0.00 | 0.00 | |
Maximum of Months | 6.10 | 6.10 | 6.10 | 3.33 | -8.8 | 37.00 | 415.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -0.4 | 16-JAN-12:00 | 0.00 | -1.1 | 5.70 | -6.6 | 172.50 | 3.00 |
February | 3.33 | 21-FEB-12:00 | 6.70 | -1.1 | 7.70 | -6.0 | 270.00 | 303.00 |
March | 5.46 | 26-MAR-15:00 | 11.10 | -1.1 | 5.20 | -5.7 | 53.00 | 842.00 |
April | 16.93 | 23-APR-15:00 | 26.70 | 11.10 | 11.30 | 12.03 | 75.50 | 811.00 |
May | 19.90 | 26-MAY-11:00 | 25.60 | 17.20 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 24.70 | 29-JUN-15:00 | 35.00 | 21.10 | 6.70 | 24.66 | 132.00 | 705.00 |
July | 25.75 | 15-JUL-13:00 | 31.10 | 23.90 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 23.35 | 08-AUG-14:00 | 30.60 | 20.60 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 18.67 | 01-SEP-00:00 | 19.00 | 17.50 | 2.80 | 16.30 | 0.00 | 0.00 |
October | 13.70 | 19-OCT-13:00 | 21.70 | 7.80 | 5.70 | 7.75 | 54.50 | 739.00 |
November | 14.29 | 21-NOV-12:00 | 15.00 | 13.90 | 5.20 | 11.46 | 134.50 | 25.50 |
December | 0.43 | 28-DEC-02:00 | 1.10 | -0.6 | 4.60 | -5.5 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -0.4 | 0.00 | -1.1 | 2.80 | -6.6 | 0.00 | 0.00 | |
Maximum of Months | 25.75 | 35.00 | 23.90 | 11.30 | 24.66 | 333.00 | 842.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -1.1 | 16-JAN-11:00 | -0.6 | -0.8 | 5.70 | -7.3 | 164.50 | 5.00 |
February | -0.6 | 21-FEB-08:00 | 4.40 | 2.24 | 8.80 | -6.6 | 123.00 | 89.50 |
March | 0.00 | 29-MAR-20:00 | 1.70 | 0.95 | 1.50 | -4.8 | 0.00 | 0.00 |
April | 11.10 | 23-APR-13:00 | 24.40 | 16.06 | 10.80 | 9.72 | 98.50 | 903.50 |
May | 17.20 | 26-MAY-11:00 | 25.60 | 19.90 | 6.20 | 22.64 | 300.50 | 6.00 |
June | 22.80 | 29-JUN-23:19 | 26.30 | 23.71 | 5.20 | 14.28 | 0.00 | 0.00 |
July | 23.90 | 15-JUL-13:00 | 31.10 | 25.75 | 7.70 | 18.99 | 333.00 | 421.00 |
August | 20.60 | 08-AUG-14:00 | 30.60 | 23.35 | 6.70 | 17.93 | 163.50 | 672.50 |
September | 17.92 | 01-SEP-00:10 | 19.75 | 18.15 | 3.22 | 13.22 | 0.00 | 0.00 |
October | 12.20 | 07-OCT-12:20 | 14.47 | 13.16 | 3.43 | 9.18 | 163.17 | 18.50 |
November | 13.90 | 21-NOV-12:00 | 15.00 | 14.29 | 5.20 | 11.46 | 134.50 | 25.50 |
December | -0.0 | 06-DEC-02:00 | 0.00 | -0.0 | 3.60 | -6.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -1.1 | -0.6 | -0.8 | 1.50 | -7.3 | 0.00 | 0.00 | |
Maximum of Months | 23.90 | 31.10 | 25.75 | 10.80 | 22.64 | 333.00 | 903.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 1.89 | 11.66 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 0.58 | 19.92 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 0.81 | 26.63 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 2.58 | 37.52 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 5.43 | 45.25 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 8.61 | 47.76 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 11.25 | 48.86 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 12.66 | 38.94 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 12.41 | 29.23 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 10.60 | 17.37 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 7.72 | 10.89 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 4.55 | 9.11 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 6.63 | 28.63 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 0.58 | 9.11 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 12.66 | 48.86 | 0.00 |
Report: WaterHeaterReportMonthly
For: ELECTRIC TANK
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.110840E+10 | -.102007E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -88332458.2 | 58.99 | 0.00 | 0.00 |
February | 0.103792E+10 | -958354981.8 | 0.00 | 0.00 | 672.00 | 0.00 | -79565944.0 | 59.00 | 0.00 | 0.00 |
March | 0.120335E+10 | -.111584E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -87512477.4 | 58.99 | 0.00 | 0.00 |
April | 0.108876E+10 | -.100533E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -83430756.0 | 59.00 | 0.00 | 0.00 |
May | 0.107243E+10 | -993230335.6 | 0.00 | 0.00 | 744.00 | 0.00 | -79201223.0 | 58.99 | 0.00 | 0.00 |
June | 0.100329E+10 | -930608986.4 | 0.00 | 0.00 | 720.00 | 0.00 | -72680547.7 | 58.99 | 0.00 | 0.00 |
July | 0.923754E+09 | -852038631.6 | 0.00 | 0.00 | 744.00 | 0.00 | -71715827.7 | 58.99 | 0.00 | 0.00 |
August | 0.961934E+09 | -888777789.4 | 0.00 | 0.00 | 744.00 | 0.00 | -73155722.2 | 59.00 | 0.00 | 0.00 |
September | 0.905917E+09 | -830391692.0 | 0.00 | 0.00 | 720.00 | 0.00 | -75525289.9 | 58.99 | 0.00 | 0.00 |
October | 0.950020E+09 | -864985461.2 | 0.00 | 0.00 | 744.00 | 0.00 | -85035026.2 | 58.99 | 0.00 | 0.00 |
November | 0.964249E+09 | -879472688.9 | 0.00 | 0.00 | 720.00 | 0.00 | -84776185.7 | 59.00 | 0.00 | 0.00 |
December | 0.105974E+10 | -971526139.7 | 0.00 | 0.00 | 744.00 | 0.00 | -88211458.9 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.122798E+11 | -.113106E+11 | 8760.00 | -969142916.7 | 58.99 | |||||
Minimum of Months | 0.905917E+09 | -.111584E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -88332458.2 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.120335E+10 | -830391692.0 | 0.00 | 0.00 | 744.00 | 0.00 | -71715827.7 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 243.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 265.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 254.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 296.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 401.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 409.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 352.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 344.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 299.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 255.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3785.50 | ||||||||||
Minimum of Months | 226.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 437.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.186661E+11 | 28003.97 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136810E+11 | 28003.97 | 01-FEB-00:31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.119273E+11 | 28003.97 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.555350E+10 | 28003.97 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.106493E+10 | 28003.97 | 01-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 58785827.05 | 9365.54 | 01-JUN-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 4740438.38 | 1945.19 | 18-AUG-06:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.615516E+09 | 28003.97 | 22-SEP-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.378905E+10 | 28003.97 | 02-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.808387E+10 | 28003.97 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.165829E+11 | 28003.97 | 01-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.800276E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.186661E+11 | 28003.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.105333E+12 | 77855.62 | 01-JAN-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.780679E+11 | 77855.62 | 01-FEB-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.548857E+11 | 77855.62 | 01-MAR-02:62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.228634E+11 | 77855.62 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.114885E+10 | 77855.62 | 01-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 69749239.83 | 53165.54 | 28-SEP-05:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.125487E+11 | 77855.62 | 10-OCT-01:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.452597E+11 | 77855.62 | 02-NOV-23:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.995506E+11 | 77855.62 | 01-DEC-00:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.419728E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.105333E+12 | 77855.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATERHEATINGCOIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.242311E+12 | 178667.58 | 03-JAN-10:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.179169E+12 | 178667.58 | 01-FEB-05:51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.112879E+12 | 148827.16 | 15-MAR-05:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.311822E+11 | 91989.52 | 04-APR-18:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.189224E+09 | 15813.13 | 01-MAY-04:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.448087E+10 | 45174.81 | 31-OCT-20:53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.900676E+11 | 125145.68 | 25-NOV-01:51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.228732E+12 | 178667.58 | 16-DEC-05:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.889011E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.242311E+12 | 178667.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.145867E+10 | 0.131234E+10 | 12880.50 | 26-MAY-05:03 | 10533.48 | 0.00 |
June | 0.00 | 0.00 | 0.447704E+10 | 0.361389E+10 | 21176.57 | 30-JUN-05:01 | 11833.53 | 0.00 |
July | 0.00 | 0.00 | 0.715793E+10 | 0.578135E+10 | 20381.25 | 05-JUL-05:01 | 12377.48 | 0.00 |
August | 0.00 | 0.00 | 0.584660E+10 | 0.467683E+10 | 19735.82 | 09-AUG-05:02 | 12887.41 | 0.00 |
September | 0.00 | 0.00 | 0.130637E+10 | 0.117593E+10 | 19759.76 | 01-SEP-05:02 | 12422.75 | 0.00 |
October | 0.00 | 0.00 | 17832102.47 | 17783056.08 | 1749.68 | 19-OCT-15:40 | 1734.57 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 0.00 | 0.00 |
Annual Sum or Average | 0.202644E+11 | 0.165781E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.715793E+10 | 0.578135E+10 | 21176.57 | 12887.41 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:05 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.345966E+09 | 0.281646E+09 | 11203.32 | 25-MAY-15:10 | 8696.21 | 0.00 |
June | 0.00 | 0.00 | 0.460644E+10 | 0.322215E+10 | 48547.98 | 29-JUN-18:23 | 32170.62 | 0.00 |
July | 0.00 | 0.00 | 0.905041E+10 | 0.643244E+10 | 51561.63 | 23-JUL-11:05 | 29323.67 | 0.00 |
August | 0.00 | 0.00 | 0.363192E+10 | 0.256373E+10 | 50194.91 | 08-AUG-17:12 | 30536.17 | 0.00 |
September | 0.00 | 0.00 | 0.310600E+09 | 0.237123E+09 | 14789.67 | 01-SEP-15:00 | 12020.85 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:02 | 0.00 | 0.00 |
Annual Sum or Average | 0.179453E+11 | 0.127371E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.905041E+10 | 0.643244E+10 | 51561.63 | 32170.62 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATERFAN
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.110832E+10 | 0.08 | 416.97 | 01-JAN-00:01 | 0.08 |
February | 0.977721E+09 | 0.08 | 416.97 | 01-FEB-00:05 | 0.08 |
March | 0.988708E+09 | 0.07 | 416.97 | 01-MAR-00:03 | 0.08 |
April | 0.452605E+09 | 0.03 | 416.97 | 01-APR-00:10 | 0.08 |
May | 9069189.93 | 0.00 | 416.97 | 01-MAY-00:10 | 0.08 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.182410E+09 | 0.01 | 416.97 | 10-OCT-02:20 | 0.08 |
November | 0.911339E+09 | 0.07 | 416.97 | 01-NOV-00:10 | 0.08 |
December | 0.111632E+10 | 0.08 | 416.97 | 01-DEC-00:02 | 0.08 |
Annual Sum or Average | 0.574649E+10 | 0.03 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.111632E+10 | 0.08 | 416.97 | 0.08 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.134645E+10 | 0.78 | 1122.25 | 02-JAN-08:50 | 0.98 |
February | 0.118040E+10 | 0.73 | 1122.25 | 01-FEB-08:15 | 0.98 |
March | 0.130470E+10 | 0.61 | 1122.25 | 01-MAR-10:00 | 0.98 |
April | 0.115920E+10 | 0.46 | 1122.25 | 01-APR-06:40 | 0.98 |
May | 0.116768E+10 | 0.39 | 1122.25 | 01-MAY-06:20 | 0.98 |
June | 0.116172E+10 | 0.39 | 1122.25 | 01-JUN-09:20 | 0.97 |
July | 0.112684E+10 | 0.37 | 1122.25 | 01-JUL-06:30 | 0.97 |
August | 0.121029E+10 | 0.40 | 1122.25 | 01-AUG-06:20 | 0.96 |
September | 0.111724E+10 | 0.38 | 1122.25 | 01-SEP-09:40 | 0.96 |
October | 0.113649E+10 | 0.39 | 1122.25 | 02-OCT-07:00 | 0.97 |
November | 0.113958E+10 | 0.52 | 1122.25 | 01-NOV-06:50 | 0.97 |
December | 0.132165E+10 | 0.75 | 1122.25 | 01-DEC-08:20 | 0.98 |
Annual Sum or Average | 0.143722E+11 | 0.51 | |||
Minimum of Months | 0.111724E+10 | 0.37 | 1122.25 | 0.96 | |
Maximum of Months | 0.134645E+10 | 0.78 | 1122.25 | 0.98 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.390541E+10 | 0.82 | 2088.55 | 02-JAN-07:30 | 0.94 |
February | 0.332638E+10 | 0.83 | 2088.55 | 01-FEB-10:10 | 0.94 |
March | 0.324086E+10 | 0.83 | 2088.55 | 01-MAR-07:40 | 0.94 |
April | 0.256031E+10 | 0.70 | 2088.55 | 01-APR-06:20 | 0.94 |
May | 0.217945E+10 | 0.39 | 2088.55 | 01-MAY-06:30 | 0.94 |
June | 0.217096E+10 | 0.38 | 2088.55 | 08-JUN-13:20 | 0.93 |
July | 0.211718E+10 | 0.37 | 2088.55 | 01-JUL-08:40 | 0.93 |
August | 0.223654E+10 | 0.37 | 2088.55 | 01-AUG-12:30 | 0.93 |
September | 0.206790E+10 | 0.36 | 2088.55 | 01-SEP-09:30 | 0.92 |
October | 0.234520E+10 | 0.61 | 2088.55 | 03-OCT-06:40 | 0.94 |
November | 0.291263E+10 | 0.82 | 2088.55 | 01-NOV-06:40 | 0.93 |
December | 0.387626E+10 | 0.82 | 2088.55 | 01-DEC-07:40 | 0.94 |
Annual Sum or Average | 0.329391E+11 | 0.61 | |||
Minimum of Months | 0.206790E+10 | 0.36 | 2088.55 | 0.92 | |
Maximum of Months | 0.390541E+10 | 0.83 | 2088.55 | 0.94 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 3.50 | 0.39 |
February | 3.82 | 0.12 |
March | 4.19 | 0.00 |
April | 1.70 | 0.08 |
May | 1.21 | 2.83 |
June | 2.22 | 1.90 |
July | 3.28 | 0.49 |
August | 2.71 | 1.81 |
September | 1.49 | 2.20 |
October | 1.24 | 0.00 |
November | 2.80 | 0.00 |
December | 3.36 | 0.11 |
Annual Sum or Average | 31.51 | 0.63 |
Minimum of Months | 1.21 | 0.00 |
Maximum of Months | 4.19 | 2.83 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 10.24 | 0.00 |
February | 4.86 | 0.00 |
March | 0.31 | 0.00 |
April | 0.08 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 9.40 | 0.00 |
Annual Sum or Average | 24.90 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 10.24 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.12 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.12 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.12 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.134645E+10 | 0.257203E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.118040E+10 | 0.190521E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.130470E+10 | 0.168178E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.115920E+10 | 0.798453E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.152230E+10 | 0.154787E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.223502E+10 | 89766194.16 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.281236E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.258433E+10 | 7302112.20 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.142917E+10 | 0.912679E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.114089E+10 | 0.551006E+10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.113958E+10 | 0.115597E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.132165E+10 | 0.230389E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.191761E+11 | 0.112241E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.113958E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.281236E+10 | 0.257203E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.390541E+10 | 0.139522E+12 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.332638E+10 | 0.105038E+12 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.324086E+10 | 0.765121E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.256031E+10 | 0.326296E+11 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.228449E+10 | 0.169630E+10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.350840E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.470521E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.327509E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.215618E+10 | 0.106443E+09 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.234520E+10 | 0.182191E+11 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.291263E+10 | 0.635400E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.387626E+10 | 0.132551E+12 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.380964E+11 | 0.569814E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.215618E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.470521E+10 | 0.139522E+12 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.134645E+10 | 0.00 | 0.186661E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118040E+10 | 0.00 | 0.136810E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130470E+10 | 0.00 | 0.119273E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.115920E+10 | 0.00 | 0.555350E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.116768E+10 | 0.145867E+10 | 0.106493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.116172E+10 | 0.447704E+10 | 58785827.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.112684E+10 | 0.715793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.121029E+10 | 0.584660E+10 | 4740438.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.111724E+10 | 0.130637E+10 | 0.615516E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.113649E+10 | 17832102.47 | 0.378905E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.113958E+10 | 0.00 | 0.808387E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132165E+10 | 0.00 | 0.165829E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.143722E+11 | 0.202644E+11 | 0.800276E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.111724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.134645E+10 | 0.715793E+10 | 0.186661E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.390541E+10 | 0.00 | 0.105333E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.332638E+10 | 0.00 | 0.780679E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.324086E+10 | 0.00 | 0.548857E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.256031E+10 | 0.00 | 0.228634E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217945E+10 | 0.345966E+09 | 0.114885E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.217096E+10 | 0.460644E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.211718E+10 | 0.905041E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.223654E+10 | 0.363192E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.206790E+10 | 0.310600E+09 | 69749239.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.234520E+10 | 0.00 | 0.125487E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.291263E+10 | 0.00 | 0.452597E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.387626E+10 | 0.00 | 0.995506E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.329391E+11 | 0.179453E+11 | 0.419728E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.206790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.390541E+10 | 0.905041E+10 | 0.105333E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.134645E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.257203E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.118040E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.190521E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.130470E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.168178E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.115920E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.798453E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.116768E+10 | 0.00 | 0.00 | 0.00 | 0.354626E+09 | 0.00 | 0.154787E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.116172E+10 | 0.00 | 0.00 | 0.00 | 0.107330E+10 | 0.00 | 89766194.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.112684E+10 | 0.00 | 0.00 | 0.00 | 0.168552E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.121029E+10 | 0.00 | 0.00 | 0.00 | 0.137405E+10 | 0.00 | 7302112.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.111724E+10 | 0.00 | 0.00 | 0.00 | 0.311930E+09 | 0.00 | 0.912679E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.113649E+10 | 0.00 | 0.00 | 0.00 | 4400908.97 | 0.00 | 0.551006E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.113958E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.115597E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132165E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230389E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.143722E+11 | 0.00 | 0.00 | 0.00 | 0.480383E+10 | 0.00 | 0.112241E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.111724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.134645E+10 | 0.00 | 0.00 | 0.00 | 0.168552E+10 | 0.00 | 0.257203E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.390541E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139522E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.332638E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.105038E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.324086E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.765121E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.256031E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.326296E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.217945E+10 | 0.00 | 0.00 | 0.00 | 0.105040E+09 | 0.00 | 0.169630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.217096E+10 | 0.00 | 0.00 | 0.00 | 0.133744E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.211718E+10 | 0.00 | 0.00 | 0.00 | 0.258802E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.223654E+10 | 0.00 | 0.00 | 0.00 | 0.103855E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.206790E+10 | 0.00 | 0.00 | 0.00 | 88281503.30 | 0.00 | 0.106443E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.234520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182191E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.291263E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.635400E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.387626E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132551E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.329391E+11 | 0.00 | 0.00 | 0.00 | 0.515734E+10 | 0.00 | 0.569814E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.206790E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.390541E+10 | 0.00 | 0.00 | 0.00 | 0.258802E+10 | 0.00 | 0.139522E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 578362.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.535419E+10 | 0.00 | 0.00 | 0.16 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.397351E+10 | 0.00 | 0.00 | 0.16 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.365833E+10 | 0.00 | 0.00 | 0.16 |
April | 0.121036E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.187507E+10 | 0.00 | 0.00 | 0.15 |
May | 0.426090E+09 | 66909915.20 | 0.00 | 731776.64 | 0.00 | 0.357573E+09 | 0.173387E+09 | 0.00 | 0.14 |
June | 0.150296E+09 | 0.390211E+09 | 0.00 | 2033301.05 | 0.00 | 33217382.20 | 0.279367E+09 | 0.00 | 0.15 |
July | 39828976.31 | 0.624388E+09 | 0.00 | 4352339.01 | 0.00 | 0.00 | 0.176337E+09 | 0.00 | 0.14 |
August | 0.119731E+09 | 0.345251E+09 | 0.00 | 3689191.56 | 55746.18 | 3697255.58 | 0.275665E+09 | 0.00 | 0.15 |
September | 0.555499E+09 | 14409112.55 | 0.00 | 1543375.96 | 0.00 | 0.238365E+09 | 0.337792E+09 | 0.00 | 0.14 |
October | 0.273869E+09 | 0.00 | 0.00 | 8648.05 | 0.00 | 0.152151E+10 | 10228075.73 | 0.00 | 0.14 |
November | 7899281.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.261323E+10 | 0.00 | 48916.77 | 0.14 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.487932E+10 | 0.00 | 0.00 | 0.16 |
Annual Sum or Average | 0.169483E+10 | 0.144117E+10 | 0.00 | 12358632.27 | 55746.18 | 0.245080E+11 | 0.125278E+10 | 48916.77 | 0.15 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.14 |
Maximum of Months | 0.555499E+09 | 0.624388E+09 | 0.00 | 4352339.01 | 55746.18 | 0.535419E+10 | 0.337792E+09 | 48916.77 | 0.16 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.297779E+11 | 0.00 | 0.00 | 0.35 |
February | 0.243585E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207449E+11 | 0.00 | 0.00 | 0.33 |
March | 0.118751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.149663E+11 | 0.00 | 0.00 | 0.29 |
April | 0.199578E+10 | 0.00 | 0.00 | 0.00 | 1445311.69 | 0.494637E+10 | 0.00 | 0.00 | 0.24 |
May | 0.239366E+10 | 44936807.05 | 0.00 | 59339.03 | 64234082.54 | 0.245062E+09 | 87419328.22 | 0.00 | 0.20 |
June | 0.181185E+10 | 0.808386E+09 | 0.00 | 493138.66 | 3188691.83 | 0.00 | 0.140923E+09 | 0.00 | 0.21 |
July | 0.106388E+10 | 0.115830E+10 | 0.00 | 2482033.48 | 0.00 | 0.00 | 0.572540E+09 | 0.00 | 0.20 |
August | 0.217531E+10 | 0.398798E+09 | 0.00 | 1192375.11 | 0.00 | 0.00 | 0.380313E+09 | 0.00 | 0.21 |
September | 0.327761E+10 | 10248680.84 | 0.00 | 158278.44 | 285804.09 | 51389940.97 | 61075090.22 | 0.00 | 0.20 |
October | 0.262795E+10 | 0.00 | 0.00 | 0.00 | 5526290.22 | 0.279500E+10 | 0.00 | 0.00 | 0.21 |
November | 0.721076E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106751E+11 | 0.00 | 0.00 | 0.27 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.274198E+11 | 0.00 | 0.00 | 0.34 |
Annual Sum or Average | 0.174982E+11 | 0.242067E+10 | 0.00 | 4385164.73 | 74680180.37 | 0.111622E+12 | 0.124227E+10 | 0.00 | 0.25 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.20 |
Maximum of Months | 0.327761E+10 | 0.115830E+10 | 0.00 | 2482033.48 | 64234082.54 | 0.297779E+11 | 0.572540E+09 | 0.00 | 0.35 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |