Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904
Simulation Timestamp: 2020-06-03 19:11:35
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 800.36 | 165.53 | 165.53 |
Net Site Energy | 800.36 | 165.53 | 165.53 |
Total Source Energy | 2529.07 | 523.06 | 523.06 |
Net Source Energy | 2529.07 | 523.06 | 523.06 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 2.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 15.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 476.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 99.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 43.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 24.69 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 797.64 | 2.73 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 2.73 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 15.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 476.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 99.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 0.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 42.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 24.69 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 118.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 17.17 | 0.56 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 164.97 | 0.56 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 118.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 17.17 | 0.56 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 164.97 | 0.56 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 797.637 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 797.637 | 100.00 |
Total On-Site and Utility Electric Sources | 797.637 | 100.00 |
Total Electricity End Uses | 797.637 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 5.17 |
Time Setpoint Not Met During Occupied Cooling | 2.50 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 197.33 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3C
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CA_SANDIEGO
| Meter |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| ELECTRIC TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATERHEATINGCOIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATERFAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Latitude [deg] | 32.58 |
Longitude [deg] | -117.0 |
Elevation [m] | 159.00 |
Time Zone | -8.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 14.86 |
Skylight-Roof Ratio [%] | 0.32 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 10.6337 | 47.38 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 8.5069 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 8.5069 | 2.5587 | |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.6111 | 967.03 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.6111 | 967.03 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 29-SEP-12:00 | 03-JAN-06:10 | - | - | - | 01-JUL-11:20 |
Heating | 0.00 | 28371.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 12167.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5844.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1739.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 65052.93 | 28371.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 28371.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 12167.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 3539.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1739.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 2.95 | 0.00 | 0.00 | 0.00 |
Cooling | 47.77 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1507.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 314.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 136.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 78.18 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2526.12 | 2.95 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.61 | 0.00 | 0.00 | 0.00 |
Cooling | 9.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 311.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 64.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 28.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 16.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 522.45 | 0.61 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 0.61 | 0.00 | 0.00 | 0.00 |
Cooling | 9.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 311.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 64.99 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 28.32 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 16.17 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 522.45 | 0.61 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 0.994695 |
ZONE2 FINE STORAGE DIRECT AIR | 2.20 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3UNITHEATER | 0.976839 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATERFAN | 0.976839 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATERHEATINGCOIL | 39814.24 |
PSZ-OFFICE HEATING COIL | 24520.99 |
PSZ-FINE STORAGE HEATING COIL | 69712.21 |
User-Specified Heating Design Capacity [W] | |
ZONE3HIRADIANT | 33268.55 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 0.994695 | 0.994695 | 0.994695 | 0.994695 | 0.994695 | 0.994695 | 1.00 | 1.00 | 0.994695 |
PSZ-FINE STORAGE | 2.20 | 2.20 | 2.20 | 2.20 | 2.20 | 2.20 | 1.00 | 1.00 | 2.20 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE OA CONTROLLER | 0.994695 | 0.102285 |
PSZ-FINE STORAGE OA CONTROLLER | 2.20 | 0.424713 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 0.994695 | 0.994695 | 0.994695 | 0.994695 | 16495.36 | 24520.99 | 40.00 | 1.00 |
PSZ-FINE_UNITARY_PACKAGE_DX | 2.20 | 2.20 | 2.20 | 2.20 | 44211.09 | 69712.21 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 0.994690 | 0.497345 | 0.994690 | 16465.65 | 16495.36 | 8247.68 | 16495.36 | 0.797993 | 0.797990 | 0.797990 | 0.797990 |
PSZ-FINE STORAGE COOLING COIL | 2.20 | 1.10 | 2.20 | 41833.60 | 44211.09 | 22105.54 | 44211.09 | 0.733496 | 0.733500 | 0.733500 | 0.733500 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 0.994695 | 1134.06 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 2.20 | 2405.12 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE FRONT DOOR | |
OFFICE LEFT WALL | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | OFFICE LEFT WALL DOOR | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.80 | 14.30 | 13.60 | 13.20 | 13.30 | 12.60 | 15.30 | 15.60 | 17.70 | 19.40 | 19.70 | 18.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 | 32.58 | -116.98 | -8.00 | 159.00 | 99429 | 1.1818 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 16.00 | 7.10 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 66 | 42 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 0.00 | 11 | 6 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 14.86 | 6 | 30 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 5.0 | 47.376 | 2.111E-002 | 10.634 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 18.707 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 0.0 | N/A | 0.000 | 8.507 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8.507 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 0.0 | N/A | 0.000 | 8.507 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 11.066 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 5.0 | 2.111E-002 | 47.376 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | BLDG_LIGHT_OFFICE_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 2518.900 | 10.634 | 503.780 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 2518.900 |
2 | FINE STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 11853.648 | 8.507 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 11853.648 |
3 | BULK STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 27263.390 | 8.507 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 27263.390 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 1912.500 | 8.074 | 382.500 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 8200.120 | 2.559 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.3263 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.3263 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL | 19 | 3 | 4 | 0.167 | 0.5084 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL | 21 | 3 | 4 | 0.167 | 0.5084 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 32 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 33 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 35 | 1 | 1 | 0.167 | 8.233 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 36 | 1 | 1 | 0.167 | 8.233 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 37 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 38 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 39 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.1926 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.7922E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.7415E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 43 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL | 44 | 3 | 4 | 0.167 | 0.5084 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 45 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.065 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 3.065 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.867 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.867 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.1215 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.1215 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.116 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.55 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 13.41 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.867 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.38866262E-07 | 0.77198350E-12 | 0.86409618E-13 | 0.0000000 |
2 | 1 | -5.2160226 | 0.42725752E-04 | -0.49098391E-04 | 0.74579932E-08 |
3 | 0 | 5.5423254 | 0.32626013 | 0.32635195 | |
4 | 2 | 0.38866262E-07 | 0.77198350E-12 | 0.86409618E-13 | 0.0000000 |
5 | 1 | -5.2160226 | 0.42725752E-04 | -0.49098391E-04 | 0.74579932E-08 |
6 | 0 | 5.5423254 | 0.32626013 | 0.32635195 | |
7 | 4 | 0.77647315E-12 | 0.13408001E-15 | -0.22253071E-14 | 0.11703322E-15 |
8 | 3 | -0.38306226E-03 | 0.35631809E-06 | -0.55549669E-04 | 0.14899307E-12 |
9 | 2 | 1.7356375 | 0.78038605E-02 | 1.1374847 | -0.73439249E-04 |
10 | 1 | -7.1338263 | 0.20239632 | -17.079215 | 0.33264924 |
11 | 0 | 5.7379043 | 0.12913194 | 16.281118 | |
12 | 4 | 0.77647315E-12 | 0.13408001E-15 | -0.22253071E-14 | 0.11703322E-15 |
13 | 3 | -0.38306226E-03 | 0.35631809E-06 | -0.55549669E-04 | 0.14899307E-12 |
14 | 2 | 1.7356375 | 0.78038605E-02 | 1.1374847 | -0.73439249E-04 |
15 | 1 | -7.1338263 | 0.20239632 | -17.079215 | 0.33264924 |
16 | 0 | 5.7379043 | 0.12913194 | 16.281118 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 8.2334905 | 8.2334905 | 8.2334905 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 8.2334905 | 8.2334905 | 8.2334905 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.21936956E-08 | -0.76657665E-15 | 0.52174295E-14 | -0.76362207E-16 |
55 | 6 | 0.54250385E-05 | 0.36865710E-08 | 0.31904099E-02 | -0.26763832E-04 |
56 | 5 | -0.38781740E-03 | 0.21819055E-05 | -0.22375527 | 0.19564212E-02 |
57 | 4 | 0.89061350E-02 | 0.99303795E-04 | 4.8300570 | -0.45269896E-01 |
58 | 3 | -0.78164548E-01 | 0.78949647E-03 | -38.024306 | 0.39868569 |
59 | 2 | 0.27748674 | 0.13132576E-02 | 116.48957 | -1.4180145 |
60 | 1 | -0.40047331 | 0.39992572E-03 | -143.91062 | 2.0490943 |
61 | 0 | 0.19524127 | 0.97244710E-05 | 60.838472 | |
62 | 7 | -0.53942680E-08 | -0.11156834E-13 | 0.16318657E-14 | -0.36257882E-16 |
63 | 6 | 0.25438785E-05 | 0.15223906E-08 | 0.31992327E-02 | -0.26837845E-04 |
64 | 5 | -0.16605865E-03 | 0.89659996E-06 | -0.22425660 | 0.19608463E-02 |
65 | 4 | 0.37075836E-02 | 0.40698259E-04 | 4.8384045 | -0.45350141E-01 |
66 | 3 | -0.32199378E-01 | 0.32283529E-03 | -38.071448 | 0.39920679 |
67 | 2 | 0.11382527 | 0.53586778E-03 | 116.58131 | -1.4192416 |
68 | 1 | -0.16395953 | 0.16275009E-03 | -143.96461 | 2.0499819 |
69 | 0 | 0.79856572E-01 | 0.39490086E-05 | 60.838472 | |
70 | 7 | -0.57660871E-08 | -0.13610624E-13 | 0.89936022E-15 | -0.28491615E-16 |
71 | 6 | 0.24333103E-05 | 0.14269892E-08 | 0.31996257E-02 | -0.26841142E-04 |
72 | 5 | -0.15663594E-03 | 0.83977476E-06 | -0.22427892 | 0.19610433E-02 |
73 | 4 | 0.34808858E-02 | 0.38103208E-04 | 4.8387759 | -0.45353710E-01 |
74 | 3 | -0.30176241E-01 | 0.30214868E-03 | -38.073544 | 0.39922996 |
75 | 2 | 0.10659492 | 0.50136596E-03 | 116.58539 | -1.4192962 |
76 | 1 | -0.15349297 | 0.15221123E-03 | -143.96701 | 2.0500213 |
77 | 0 | 0.74745977E-01 | 0.36906361E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | -0.22253071E-14 | 0.13408001E-15 | 0.77647315E-12 | 0.11703322E-15 |
85 | 3 | -0.55549669E-04 | 0.35631809E-06 | -0.38306226E-03 | 0.14899307E-12 |
86 | 2 | 1.1374847 | 0.78038605E-02 | 1.7356375 | -0.73439249E-04 |
87 | 1 | -17.079215 | 0.20239632 | -7.1338263 | 0.33264924 |
88 | 0 | 16.281118 | 0.12913194 | 5.7379043 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.63_SHGC_0.25 | 28 | 1 | VerySmooth | 3.582 | 0.253 | 0.153 | 0.250 |
2 | SKYLIGHT_U_0.65_SHGC_0.35 | 29 | 1 | VerySmooth | 3.695 | 0.347 | 0.243 | 0.351 |
3 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 30 | 1 | VerySmooth | 3.695 | 0.347 | 0.243 | 0.351 |
4 | SKYLIGHT DOUBLE CLEAR | 34 | 3 | VerySmooth | 3.715 | 0.720 | 0.644 | 0.817 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.15304 | 0.57918 | 0.57918 | 0.25000 | 0.16143 | 0.23877 | 0.00000 | 0.84000 | 0.84000 | 1.81224E-002 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.24267 | 0.45800 | 0.45800 | 0.35000 | 0.14371 | 0.19477 | 0.00000 | 0.84000 | 0.84000 | 1.96142E-002 | 1.00000 | No | |
3 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.24267 | 0.45800 | 0.45800 | 0.35000 | 0.14371 | 0.19477 | 0.00000 | 0.84000 | 0.84000 | 1.96142E-002 | 1.00000 | No | |
4 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
5 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 20 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | ELECTRIC TANK | 7.5708E-002 | 6154.7 | 1.055 | 0.5308 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 5.0 | 6.083E-002 | 2.568E-004 | 3.964E-004 | 0.217 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 0.889 | 6.381E-004 | 4.064E-004 | 1.084 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 3.431 | 1.071E-003 | 6.993E-004 | 0.350 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 37.760 | 1.178E-002 | N/A | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 0.944 | 2.945E-004 | N/A | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 9888.67944 | 11866.41532 | 0.82891 | 0.99469 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 30.29133 | 8.20219E-003 | 236.87965 | 5.00000 | 0.10228 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 7737.02687 | 9284.43224 | 0.22113 | 0.26536 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 3.80000 | 5.05843E-003 | 236.87965 | 5.00000 | 0.10228 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 28025.47447 | 33630.56936 | 1.83121 | 2.19745 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 31.30000 | 8.20219E-003 | 1393.40969 | 0.00000 | 0.42471 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 18845.32415 | 22614.38898 | 0.45405 | 0.54486 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 3.80000 | 5.05843E-003 | 1393.40969 | 0.00000 | 0.42471 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.97684 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 31.30000 | 8.20219E-003 | 3204.84228 | 0.00000 | 0.97684 | 0.00000 | |
6 | ZONE3 BULK STORAGE | Heating | 27723.79515 | 33268.55418 | 0.68020 | 0.97684 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 3.80000 | 5.05843E-003 | 3204.84228 | 0.00000 | 0.97684 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 14832.39 | 0.99469 | 0.99469 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 8074.33 | 0.26536 | 0.26536 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 40679.81 | 2.19745 | 2.19745 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 21744.88 | 0.54486 | 0.54486 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 0.99469 |
2 | AirTerminal:SingleDuct:Uncontrolled | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.19745 |
3 | ZoneHVAC:UnitHeater | ZONE3UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 0.97684 |
4 | Fan:ConstantVolume | ZONE3UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 0.97684 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 39814.24435 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3HIRADIANT | User-Specified Heating Design Capacity [W] | 33268.55418 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 0.99469 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.99469 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 0.99469 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 0.99469 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 0.99469 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 0.99469 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.19745 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.19745 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.19745 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 2.19745 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.19745 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 2.19745 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 0.99469 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 2.19745 |
25 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 0.99469 |
26 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.10228 |
27 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 0.99469 |
28 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 0.99469 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 0.99469 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 0.99469 |
31 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 0.99469 |
32 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.49735 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 0.99469 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 16465.65138 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 16495.36000 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 8247.68000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 16495.36000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.79799 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.79799 |
40 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.79799 |
41 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.79799 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 16495.36000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 24520.98933 |
44 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
45 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
46 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 0.99469 |
47 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1134.06143 |
48 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 24520.98933 |
49 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.19745 |
50 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.42471 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.19745 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.19745 |
53 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.19745 |
54 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.19745 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.19745 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.09873 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.19745 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 41833.59876 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 44211.09000 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 22105.54500 |
61 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 44211.09000 |
62 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.73350 |
63 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.73350 |
64 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.73350 |
65 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.73350 |
66 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 44211.09000 |
67 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 69712.21489 |
68 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
69 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
70 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.19745 |
71 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2405.12264 |
72 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 69712.21489 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 15723.5 | 11.07 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 42504.7 | 13.51 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | ML KING BIRTHDAY | Holiday | InputFile | 01/16 | 1 |
3 | WASHINGTON'S BIRTHDAY | Holiday | InputFile | 02/20 | 1 |
4 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
5 | FOURTH OF JULY | Holiday | InputFile | 07/04 | 1 |
6 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
7 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
8 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
9 | THANKSGIVING DAY | Holiday | InputFile | 11/23 | 1 |
10 | CHRISTMAS DAY | Holiday | InputFile | 12/25 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 14 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 2.0554621943E-002 | 1.6484074257E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 0.1151956373 | 0.1455355002 | Pass | Pass | 1.3274207729 | 7.6069258283 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 2.3778629225E-002 | 2.4008897643E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 3.80 | 0.00 | 3.80 | Wetbulb [C] | 3.00 | 120.00 |
SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 31.30 | 8.90 | 18.40 | Wetbulb [C] | 4.10 | 280.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 39.02 | 30.56 | 0.00 | 90.00 | N |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.472 | 0.508 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.312 | 0.326 | 1393.41 | 1393.41 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.472 | 0.508 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.472 | 0.508 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.472 | 0.508 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.312 | 0.326 | 3204.84 | 3189.98 | 270.00 | 0.00 | |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.193 | 236.88 | 236.88 | 90.00 | 180.00 | ||
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.079 | 1156.53 | 1156.53 | 90.00 | 180.00 | ||
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.074 | 3204.84 | 3204.84 | 90.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.63_SHGC_0.25 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 3.582 | 0.253 | 0.250 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.63_SHGC_0.25 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 3.582 | 0.253 | 0.250 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.63_SHGC_0.25 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 3.582 | 0.253 | 0.250 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.63_SHGC_0.25 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 3.582 | 0.253 | 0.250 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C5 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C5 | SEMIHTDSKYLIGHT_U_0.65_SHGC_0.35 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.695 | 0.347 | 0.351 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
Total or Average | 32.53 | 3.634 | 0.296 | 0.296 | ||||||||||||
North Total or Average | 6.51 | 3.582 | 0.253 | 0.250 | ||||||||||||
Non-North Total or Average | 26.02 | 3.647 | 0.307 | 0.308 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE LEFT WALL |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | 10.6337 | 236.88 | 2518.90 | LightsWired | BLDG_LIGHT_OFFICE_SCH | 65.78 | 168.00 | 64.76 | 0.0000 | Y | 30.62 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | 8.5069 | 1393.41 | 11853.65 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 135.00 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | 8.5069 | 3204.84 | 27263.39 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 310.50 |
Interior Lighting Total | 8.6111 | 4835.13 | 41635.94 | 476.13 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 6311.00 | AstronomicalClock | - | 83.75 | 83.75 | 99.22 | |
Exterior Lighting Total | 6311.00 | 99.22 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 16495.36 | 13163.13 | 3332.23 | 0.80 | 3.91 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 44211.09 | 32428.83 | 11782.26 | 0.73 | 3.30 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 15723.5 | 11.07 | ||||
PSZ-FINE STORAGE COOLING COIL | 42504.7 | 13.51 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATERHEATINGCOIL | Coil:Heating:Fuel | 39814.24 | 0.80 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 24520.99 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 69712.21 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 0.98 | 90.76 | 92.91 | 1.00 | 4.17 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.55 | 622.50 | 0.99 | 1134.06 | 1140.11 | 1.00 | 1.36 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.57 | 622.50 | 2.20 | 2405.12 | 1094.51 | 1.00 | 1.27 | General | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
ELECTRIC TANK | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.53 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 9888.68 | 11866.42 | 50.09 | 0.829 | 0.995 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 23.90 | 23.90 | 0.00812 | 30.29 | 0.00820 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 28025.47 | 33630.57 | 24.14 | 1.831 | 2.197 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 26.70 | 26.70 | 0.00802 | 31.30 | 0.00820 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.977 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 10.00 | 0.00 | 0.00385 | 31.30 | 0.00820 | 0.977 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 7737.03 | 9284.43 | 39.19 | 0.221 | 0.265 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 21.10 | 21.10 | 0.00768 | 3.80 | 0.00506 | 0.102 | 0.00 |
ZONE2 FINE STORAGE | 18845.32 | 22614.39 | 16.23 | 0.454 | 0.545 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 15.56 | 15.56 | 0.00655 | 3.80 | 0.00506 | 0.425 | 0.00 |
ZONE3 BULK STORAGE | 27723.80 | 33268.55 | 10.38 | 0.680 | 0.977 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 10.00 | 10.00 | 0.00778 | 3.80 | 0.00506 | 0.977 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 0.99 | 0.99 | 0.27 | 0.27 | 0.9947 | 0.9947 | 0.9947 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 2.20 | 2.20 | 0.54 | 0.54 | 2.1975 | 2.1975 | 2.1975 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | 39814.244 | 39814.244 | -999.0 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 39814.24 | 39814.24 | 0.976839 | 3.80 | 3.80 | 0.00505843 | 43.33 | 26.86 | 0.01600000 | 3.80 | 0.00505843 | 3.80 | 0.0000 | 10.00 | 0.00777639 | 100.0000 | 33268.55 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 16495.360 | 0.000 | 0.994690 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 16495.36 | 16120.84 | 0.994690 | 24.56 | 16.06 | 0.00813155 | 12.00 | 11.09 | 0.00800000 | 30.29 | 0.00820219 | 18.07 | 10.2831 | 23.90 | 0.00812345 | 43.2018 | 9888.68 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 24520.989 | 24520.989 | -999.0 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 24520.99 | 24520.99 | 0.994695 | 14.38 | 10.72 | 0.00666956 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 10.2830 | 21.10 | 0.00768013 | 48.4554 | 7737.03 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 44211.090 | 0.000 | 2.197450 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 44211.09 | 43843.30 | 2.197450 | 27.59 | 17.05 | 0.00805756 | 12.00 | 11.09 | 0.00800000 | 31.30 | 0.00820219 | 18.40 | 19.3275 | 26.70 | 0.00802291 | 36.1263 | 28025.47 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 69712.215 | 69712.215 | -999.0 | -999.0 | -999.000 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 69712.21 | 69712.21 | 2.197451 | 6.39 | 5.56 | 0.00538817 | 40.00 | 20.93 | 0.00800000 | 3.80 | 0.00505843 | 3.80 | 19.3275 | 15.56 | 0.00655379 | 58.6529 | 18845.32 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 39814.244 | 39814.244 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1034.5832 | 1004.8586 | 1.1818 | ZONE3UNITHEATERFAN | Fan:ConstantVolume | 0.976839 | 1.15440764 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 24:00:00 | 39814.24 | 39814.24 | 1.0000 | 1.15440764 | 0.976839 | 3.80 | 3.80 | 0.00505843 | 16505.0 | 43.33 | 26.86 | 0.01600000 | 84847.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 39814.24 | 3.80 | 0.00505843 | 3.80 | 0.00000000 | 0.0000 | 10.00 | 0.00777639 | 10.00 | 0.00777639 | 100.0000 | 33268.55 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 16495.360 | 0.000 | 0.994690 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.9561 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:40:00 | 16495.36 | 16120.84 | 1.0000 | 1.17550342 | 0.994690 | 24.56 | 16.06 | 0.00813155 | 45383.4 | 12.00 | 11.09 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 16495.36 | 30.29 | 0.00820219 | 18.07 | 0.10228487 | 10.2831 | 23.90 | 0.00812345 | 23.90 | 0.00812345 | 43.2018 | 9888.68 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24520.989 | 24520.989 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.994695 | 1.17550915 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 09:00:00 | 24520.99 | 24520.99 | 1.0000 | 1.17550915 | 0.994695 | 14.38 | 10.72 | 0.00666956 | 31304.7 | 40.00 | 20.93 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24520.99 | 3.80 | 0.00505843 | 3.80 | 0.10228487 | 10.2830 | 21.01 | 0.00768013 | 21.10 | 0.00768013 | 48.4554 | 7737.03 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 44211.090 | 0.000 | 2.197450 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.8186 | 1004.8586 | 1.1818 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 14:30:00 | 44211.09 | 43843.30 | 1.0000 | 2.59689952 | 2.197450 | 27.59 | 17.05 | 0.00805756 | 48287.3 | 12.00 | 11.09 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 44211.09 | 31.30 | 0.00820219 | 18.40 | 0.42471267 | 19.3275 | 26.70 | 0.00802291 | 26.70 | 0.00802291 | 36.1263 | 28025.47 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 69712.215 | 69712.215 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.1818 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.197451 | 2.59690119 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | SAN.DIEGO-BROWN.FIELD.MUNI.AP_CA_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 69712.21 | 69712.21 | 1.0000 | 2.59690119 | 2.197451 | 6.39 | 5.56 | 0.00538817 | 19963.1 | 40.00 | 20.93 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 69712.21 | 3.80 | 0.00505843 | 3.80 | 0.42471267 | 19.3275 | 15.56 | 0.00655379 | 15.56 | 0.00655379 | 58.6529 | 18845.32 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PSZ-OFFICE OA CONTROLLER | DifferentialDryBulb | 0.10 | 0.99 | - | |||
PSZ-FINE STORAGE OA CONTROLLER | DifferentialDryBulb | 0.42 | 2.20 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 1490.33 | 1897.33 | 197.33 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 |
Facility | 1490.33 | 1897.33 | 197.33 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 5.17 | 2.50 | 5.17 | 2.50 |
ZONE2 FINE STORAGE | 0.17 | 4.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 5.33 | 6.50 | 5.17 | 2.50 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.74 | 5.00 | 1010.76 | 1.388 | 0.374 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.74 | 5.00 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 14 | 14 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
Electricity:Building | 615.73 | 4938.86 | 01-JAN-00:10 | 47606.95 | 31-JUL-12:30 |
Electricity:Zone:ZONE1 OFFICE | 62.57 | 1027.15 | 01-JAN-00:10 | 3852.05 | 02-JAN-08:10 |
InteriorLights:Electricity | 476.13 | 4365.11 | 01-JAN-00:10 | 35189.04 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 30.62 | 453.40 | 01-JAN-00:10 | 1939.55 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 476.13 | 4365.11 | 01-JAN-00:10 | 35189.04 | 02-JAN-09:10 |
Electricity:Zone:ZONE2 FINE STORAGE | 135.00 | 1185.36 | 01-JAN-00:10 | 10075.60 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 135.00 | 1185.36 | 01-JAN-00:10 | 10075.60 | 02-JAN-09:10 |
Electricity:Zone:ZONE3 BULK STORAGE | 418.16 | 2726.34 | 01-JAN-00:10 | 33679.30 | 19-JUL-10:50 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 310.51 | 2726.34 | 01-JAN-00:10 | 23173.88 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Electricity:Plant | 24.69 | 483.00 | 10-JAN-06:10 | 1799.27 | 07-FEB-12:40 |
WaterSystems:Electricity | 24.69 | 483.00 | 10-JAN-06:10 | 1799.27 | 07-FEB-12:40 |
Water Heater:WaterSystems:Electricity | 24.69 | 483.00 | 10-JAN-06:10 | 1799.27 | 07-FEB-12:40 |
Fans:Electricity | 43.24 | 0.00 | 01-JAN-00:10 | 5844.48 | 29-SEP-10:20 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 0.31 | 0.00 | 01-JAN-00:10 | 2305.29 | 16-OCT-14:50 |
Ventilation (simple):Fans:Electricity | 0.31 | 0.00 | 01-JAN-00:10 | 2305.29 | 16-OCT-14:50 |
ElectricityPurchased:Facility | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
ElectricityPurchased:Plant | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
Cogeneration:ElectricityPurchased | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
ElectricityNet:Plant | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
Cogeneration:ElectricityNet | 797.64 | 5421.86 | 01-JAN-07:10 | 65052.93 | 29-SEP-13:00 |
Electricity:HVAC | 58.01 | 0.00 | 01-JAN-00:10 | 16525.42 | 16-OCT-11:10 |
General:Fans:Electricity | 42.92 | 0.00 | 01-JAN-00:10 | 3539.18 | 10-JAN-07:10 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 15.08 | 0.00 | 01-JAN-00:10 | 12986.24 | 16-OCT-11:10 |
ExteriorLights:Electricity | 99.22 | 0.00 | 01-JAN-07:00 | 6311.00 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 99.22 | 0.00 | 01-JAN-07:00 | 6311.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 2.73 | 0.00 | 01-JAN-00:10 | 28371.93 | 03-JAN-06:10 |
Gas:HVAC | 2.73 | 0.00 | 01-JAN-00:10 | 28371.93 | 03-JAN-06:10 |
Heating:Gas | 2.73 | 0.00 | 01-JAN-00:10 | 28371.93 | 03-JAN-06:10 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 01-JUL-11:20 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 144.42 | 0.00 | 01-JAN-00:10 | 69571.67 | 16-OCT-12:00 |
EnergyTransfer:Building | 83.71 | 0.00 | 01-JAN-00:10 | 29904.61 | 16-OCT-12:00 |
EnergyTransfer:Zone:ZONE1 OFFICE | 36.99 | 0.00 | 01-JAN-00:10 | 12729.06 | 03-JAN-06:10 |
Heating:EnergyTransfer | 6.22 | 0.00 | 01-JAN-00:10 | 21461.91 | 03-JAN-06:10 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 2.70 | 0.00 | 01-JAN-00:10 | 12729.06 | 03-JAN-06:10 |
Cooling:EnergyTransfer | 77.49 | 0.00 | 01-JAN-00:10 | 29904.61 | 16-OCT-12:00 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 34.29 | 0.00 | 01-JAN-00:10 | 10331.86 | 16-OCT-11:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 46.72 | 0.00 | 01-JAN-00:10 | 21120.39 | 09-JUL-15:30 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 3.52 | 0.00 | 01-JAN-00:10 | 14413.84 | 03-JAN-04:10 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 43.20 | 0.00 | 01-JAN-00:10 | 21120.39 | 09-JUL-15:30 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 60.71 | 0.00 | 01-JAN-00:10 | 40299.57 | 31-JUL-14:20 |
HeatingCoils:EnergyTransfer | 1.85 | 0.00 | 01-JAN-00:10 | 21057.66 | 03-JAN-06:10 |
CoolingCoils:EnergyTransfer | 58.87 | 0.00 | 01-JAN-00:10 | 40299.57 | 31-JUL-14:20 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 2.698 | -34.290 | 0.000 | 0.000 | 3.634 | 30.619 | 31.946 | 8.593 | 0.000 | 0.216 | 0.000 | 0.000 | -9.223 | 0.000 | -12.522 | -21.672 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 3.524 | -43.197 | 0.000 | 0.000 | 0.000 | 135.003 | 0.000 | 0.000 | 0.000 | 0.392 | 0.000 | 0.000 | 0.000 | 0.000 | -69.164 | -26.558 |
ZONE3 BULK STORAGE | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 310.507 | 107.336 | 25.347 | 0.000 | 6.091 | 0.003 | 0.000 | -10.462 | 0.000 | -332.823 | -105.995 |
Total Facility | 0.000 | 0.000 | 6.222 | -77.487 | 0.000 | 0.000 | 3.634 | 476.129 | 139.282 | 33.940 | 0.000 | 6.700 | 0.003 | 0.000 | -19.686 | 0.000 | -414.509 | -154.225 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 17-OCT-05:01 | 0.00 | 0.00 | 0.00 | -20661.49 | 0.00 | 0.00 | 34.23 | 579.35 | 573.75 | 0.00 | 0.00 | 0.00 | 20633.10 | 0.00 | -529.38 | 0.00 | -629.55 | 0.00 |
ZONE2 FINE STORAGE | 04-JUL-16:51 | 0.00 | 0.00 | 0.00 | -43786.67 | 0.00 | 0.00 | 0.00 | 1185.36 | 0.00 | 0.00 | 0.00 | 0.00 | 42601.31 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 04-JUL-16:51 | 0.00 | 0.00 | 0.00 | -43786.67 | 0.00 | 0.00 | 0.00 | 4365.11 | 573.75 | 1879.16 | 0.00 | 0.00 | 36968.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 09-JAN-06:01 | 0.00 | 0.00 | 24906.19 | 0.00 | 0.00 | 0.00 | 53.74 | 579.35 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -813.13 | 0.00 | -1300.44 | -23999.46 |
ZONE2 FINE STORAGE | 02-JAN-06:10 | 0.00 | 0.00 | 60147.83 | 0.00 | 0.00 | 0.00 | 0.00 | 1185.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -2433.07 | -58900.12 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 03-JAN-06:01 | 0.00 | 0.00 | 74234.24 | 0.00 | 0.00 | 0.00 | 55.63 | 4491.05 | 2623.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1367.88 | 0.00 | -13436.04 | -66600.78 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9947 | 0.0000 | 5.0000 | 1.0000 | 0.1023 | 0.9947 | 0.1028 | 1.0000 | 0.1023 | 0.1028 | ||
PSZ-FINE STORAGE | 2.1975 | 0.0000 | 0.0000 | 1.0000 | 0.4247 | 2.1975 | 0.1933 | 1.0000 | 0.4247 | 0.1933 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 0.9947 | 0.0000 | 5.0000 | 1.0000 | 0.1023 | 0.9947 | 1.0000 | 1.0000 | 0.1023 | 0.1028 | ||
PSZ-FINE STORAGE | 2.1975 | 0.0000 | 0.0000 | 1.0000 | 0.4247 | 2.1975 | 1.0000 | 1.0000 | 0.4247 | 0.1933 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 5.0000 | 0.000432 | 236.88 | 0.1023 | 1.0000 | 0.1023 | 1.000 | 0.1023 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 0.0000 | 0.000305 | 1393.41 | 0.4247 | 1.0000 | 0.4247 | 1.000 | 0.4247 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 5.00 | 0.000432 | 236.8796 | 0.1023 | 0.1023 | 0.1023 |
PSZ-FINE STORAGE | 0.00 | 0.000305 | 1393.4097 | 0.4247 | 0.4247 | 0.4247 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 0.9947 | 0.9947 | 0.9947 | 0.1023 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 2.1975 | 2.1975 | 2.1975 | 0.4247 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9947 | 0.9947 | 0.9947 | 0.9947 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.1975 | 2.1975 | 2.1975 | 2.1975 | 0.4247 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 0.9947 | 0.9947 | 0.9947 | 0.1023 | 0.3855 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 2.1975 | 2.1975 | 2.1975 | 0.4247 | 0.7795 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 0.9947 | 0.9947 | 0.9947 | 0.9947 | 0.1023 | 1.0000 |
PSZ-FINE STORAGE | 2.1975 | 2.1975 | 2.1975 | 2.1975 | 0.4247 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:35
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** San Diego-Brown Field Muni AP CA USA TMY3 WMO#=722904 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 0.00 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 5.17 |
Number of hours cooling loads not met | 2.50 |
Number of hours not met | 7.67 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 2.73 | 28371.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 15.08 | 12986.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 476.13 | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 99.22 | 6311.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.28 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 0.31 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 42.92 | 3539.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 24.69 | 1799.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.28 | 797.64 |
Natural Gas | 0.00 | 2.73 |
Additional | 0.00 | 0.00 |
Total | 139.28 | 800.36 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 98.47 |
Space Heating | 0.00 |
Space Cooling | 3.12 |
Fans (All) | 8.94 |
Service Water Heating | 5.11 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 164.97 |
Subtotal | 164.97 |
Natural Gas [MJ/m2] | |
Space Heating | 0.56 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 0.56 |
Subtotal | 0.56 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 59.49 |
Space Heating | 0.34 |
Space Cooling | 1.88 |
Fans (All) | 5.40 |
Service Water Heating | 3.08 |
Receptacle Equipment | 17.40 |
Miscellaneous | 12.40 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
OFFICE LIGHT SCHEDULE | 3792. | 8760. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
STORAGE LIGHT SCHEDULE | 3232. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
OFFICE LIGHT WITH SENSOR SCHEDULE | 3430. | 8760. |
STORAGE LIGHT WITH SENSOR SCHEDULE | 2877. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BLDG_LIGHT_OFFICE_SCH | 3430. | 8760. |
BLDG_LIGHT_STORAGE_SCH | 3232. | 8760. |
BLDG_OCC_SCH | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | HEATING SETPOINT WITH SB | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2009
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 3C
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CA_SANDIEGO
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.122289E+10 |
February | 0.000 | 0.358425E+09 |
March | 0.000 | 0.624890E+09 |
April | 0.000 | 0.419623E+08 |
May | 0.000 | 3486989.418 |
June | 0.000 | 0.000 |
July | 0.000 | 0.000 |
August | 0.000 | 0.000 |
September | 0.000 | 0.000 |
October | 0.000 | 0.000 |
November | 0.000 | 0.910139E+08 |
December | 0.000 | 0.383338E+09 |
Annual Sum or Average | 0.272601E+10 | |
Minimum of Months | 0.000 | 0.000 |
Maximum of Months | 0.000 | 0.122289E+10 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.844809E+09 | 3543.90 | 21-JAN-15:30 | 14.00 | 10.94 | 0.235331E+09 | 301.61 | 18-JAN-15:00 | 22.00 | 15.38 |
February | 0.720928E+09 | 3489.11 | 03-FEB-15:10 | 22.67 | 9.05 | 0.218382E+09 | 301.63 | 01-FEB-13:50 | 19.83 | 15.74 |
March | 0.924232E+09 | 4424.12 | 23-MAR-15:50 | 21.17 | 17.22 | 0.254601E+09 | 301.60 | 22-MAR-15:00 | 19.00 | 15.88 |
April | 0.242386E+10 | 17179.97 | 28-APR-05:03 | 14.00 | 12.23 | 0.246107E+09 | 301.62 | 13-APR-13:30 | 20.50 | 15.06 |
May | 0.297320E+10 | 17643.28 | 04-MAY-05:03 | 14.33 | 12.38 | 0.257570E+09 | 301.64 | 24-MAY-10:00 | 21.00 | 15.41 |
June | 0.425357E+10 | 18915.84 | 23-JUN-05:01 | 15.17 | 12.71 | 0.258671E+09 | 301.61 | 03-JUN-15:09 | 19.00 | 14.24 |
July | 0.548117E+10 | 18358.43 | 10-JUL-05:01 | 17.00 | 13.93 | 0.248972E+09 | 301.62 | 28-JUL-13:00 | 23.00 | 19.54 |
August | 0.571140E+10 | 17800.92 | 22-AUG-05:02 | 15.00 | 13.18 | 0.268888E+09 | 301.63 | 15-AUG-15:00 | 23.00 | 19.54 |
September | 0.441334E+10 | 18796.54 | 29-SEP-05:01 | 18.30 | 11.31 | 0.248895E+09 | 301.62 | 09-SEP-13:30 | 23.00 | 18.41 |
October | 0.399016E+10 | 20662.93 | 17-OCT-05:01 | 17.00 | 8.53 | 0.248224E+09 | 301.64 | 18-OCT-12:20 | 23.67 | 17.92 |
November | 0.148166E+10 | 3776.94 | 18-NOV-15:30 | 23.50 | 13.89 | 0.234340E+09 | 301.62 | 30-NOV-15:09 | 20.50 | 12.90 |
December | 0.107112E+10 | 3762.37 | 05-DEC-15:20 | 24.33 | 12.94 | 0.240437E+09 | 301.62 | 20-DEC-14:50 | 19.20 | 11.86 |
Annual Sum or Average | 0.342894E+11 | 0.296042E+10 | ||||||||
Minimum of Months | 0.720928E+09 | 3489.11 | 14.00 | 8.53 | 0.218382E+09 | 301.60 | 19.00 | 11.86 | ||
Maximum of Months | 0.571140E+10 | 20662.93 | 24.33 | 17.22 | 0.268888E+09 | 301.64 | 23.67 | 19.54 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.660845E+09 | 6898.33 | 24-JAN-07:10 | 13.67 | 10.11 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.762716E+09 | 6851.80 | 28-FEB-07:10 | 11.33 | 9.16 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.113783E+10 | 10043.63 | 10-MAR-07:10 | 10.67 | 7.38 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.194688E+10 | 40753.73 | 30-APR-13:41 | 24.00 | 16.61 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.228533E+10 | 11315.59 | 03-MAY-13:00 | 24.00 | 15.03 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.517286E+10 | 41373.20 | 25-JUN-16:31 | 21.00 | 16.51 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.101576E+11 | 43790.65 | 04-JUL-16:51 | 19.00 | 15.26 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.997714E+10 | 39802.35 | 20-AUG-16:31 | 21.20 | 17.14 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.541935E+10 | 38891.32 | 30-SEP-17:11 | 25.00 | 17.43 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.404374E+10 | 37983.74 | 15-OCT-13:43 | 31.17 | 15.31 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.868718E+09 | 8724.45 | 29-NOV-07:10 | 13.33 | 4.13 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.763952E+09 | 7269.94 | 06-DEC-07:10 | 14.33 | 6.65 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.431969E+11 | 0.00 | ||||||||
Minimum of Months | 0.660845E+09 | 6851.80 | 10.67 | 4.13 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.101576E+11 | 43790.65 | 31.17 | 17.43 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 | 8.36 | 0.00 | 0.00 | 01-JAN-00:10 | 8.83 | 8.36 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 | 11.35 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 | 6.61 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 | 0.00 | 0.00 | 01-APR-00:10 | 9.63 | 8.61 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 | 14.50 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 | 12.03 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 | 15.81 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 | 17.20 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 | 14.82 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 | 17.39 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 | 11.06 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 | 5.43 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | 7.63 | 5.43 | 0.00 | 0.00 | 7.63 | 5.43 | ||
Maximum of Months | 0.00 | 0.00 | 18.42 | 17.39 | 0.00 | 0.00 | 18.42 | 17.39 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.709023E+09 | 24906.36 | 09-JAN-06:01 | 2.17 |
February | 0.391264E+09 | 24576.04 | 28-FEB-06:01 | 10.17 |
March | 0.576522E+09 | 24816.49 | 30-MAR-05:01 | 4.97 |
April | 0.135337E+09 | 24687.36 | 01-APR-05:01 | 7.83 |
May | 0.100175E+09 | 2267.33 | 15-MAY-06:10 | 11.33 |
June | 55634101.12 | 2571.91 | 21-JUN-06:05 | 17.17 |
July | 3762640.44 | 2181.59 | 15-JUL-06:05 | 17.17 |
August | 9666105.68 | 2226.63 | 15-AUG-06:05 | 18.17 |
September | 46590004.70 | 1695.57 | 30-SEP-06:05 | 23.78 |
October | 59282527.58 | 2802.38 | 16-OCT-06:05 | 18.33 |
November | 0.195686E+09 | 15076.94 | 27-NOV-06:03 | 10.67 |
December | 0.414744E+09 | 24440.19 | 15-DEC-06:02 | 6.00 |
Annual Sum or Average | 0.269769E+10 | |||
Minimum of Months | 3762640.44 | 1695.57 | 2.17 | |
Maximum of Months | 0.709023E+09 | 24906.36 | 23.78 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.852274E+09 | 60148.33 | 02-JAN-06:10 | 11.00 |
February | 0.232509E+09 | 2597.89 | 27-FEB-08:00 | 9.00 |
March | 0.270050E+09 | 13581.10 | 30-MAR-04:35 | 4.73 |
April | 0.250251E+09 | 2336.81 | 21-APR-07:00 | 13.00 |
May | 0.185240E+09 | 2567.63 | 25-MAY-07:00 | 14.00 |
June | 0.176122E+09 | 2437.81 | 06-JUN-07:00 | 17.00 |
July | 0.117766E+09 | 2321.76 | 08-JUL-06:50 | 16.83 |
August | 0.176309E+09 | 2307.78 | 21-AUG-07:00 | 17.00 |
September | 0.175708E+09 | 2503.47 | 27-SEP-07:00 | 16.00 |
October | 0.206018E+09 | 2373.28 | 14-OCT-08:70 | 27.67 |
November | 0.324014E+09 | 2483.77 | 01-NOV-07:00 | 11.00 |
December | 0.558024E+09 | 2860.94 | 16-DEC-13:00 | 26.00 |
Annual Sum or Average | 0.352429E+10 | |||
Minimum of Months | 0.117766E+09 | 2307.78 | 4.73 | |
Maximum of Months | 0.852274E+09 | 60148.33 | 27.67 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 8.83 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 13.23 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 7.63 |
April | 0.00 | 0.00 | 01-APR-00:10 | 9.63 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 15.20 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 13.07 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 16.43 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.07 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 16.07 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 18.42 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 14.77 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 10.63 |
Annual Sum or Average | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 7.63 | |
Maximum of Months | 0.00 | 0.00 | 18.42 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.256100E+10 | 1939.55 | 02-JAN-08:09 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.233575E+10 | 1939.55 | 01-FEB-08:09 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.266872E+10 | 1939.55 | 01-MAR-08:09 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.252182E+10 | 1939.55 | 01-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.261486E+10 | 1939.55 | 01-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.257569E+10 | 1939.55 | 01-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.256100E+10 | 1939.55 | 01-JUL-07:10 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.266872E+10 | 1939.55 | 01-AUG-07:10 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.252182E+10 | 1939.55 | 01-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.256100E+10 | 1939.55 | 02-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.246796E+10 | 1939.55 | 01-NOV-07:10 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.256100E+10 | 1939.55 | 01-DEC-08:09 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.306193E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.233575E+10 | 1939.55 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.266872E+10 | 1939.55 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.112294E+11 | 10075.60 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.102778E+11 | 10075.60 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.118738E+11 | 10075.60 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.111270E+11 | 10075.60 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.115516E+11 | 10075.60 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.114492E+11 | 10075.60 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.112294E+11 | 10075.60 | 01-JUL-08:09 | 0.00 | 0.00 |
August | 0.118738E+11 | 10075.60 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.111270E+11 | 10075.60 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.112294E+11 | 10075.60 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.108048E+11 | 10075.60 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.112294E+11 | 10075.60 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.135003E+12 | ||||
Minimum of Months | 0.102778E+11 | 10075.60 | 0.00 | 0.00 | |
Maximum of Months | 0.118738E+11 | 10075.60 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.258277E+11 | 23173.88 | 02-JAN-09:09 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.236390E+11 | 23173.88 | 01-FEB-09:09 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.273097E+11 | 23173.88 | 01-MAR-09:09 | 0.956462E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.255921E+11 | 23173.88 | 01-APR-08:09 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.265687E+11 | 23173.88 | 01-MAY-08:09 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.263332E+11 | 23173.88 | 01-JUN-08:09 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.258277E+11 | 23173.88 | 01-JUL-08:09 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.273097E+11 | 23173.88 | 01-AUG-08:09 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.255921E+11 | 23173.88 | 01-SEP-08:09 | 0.885613E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.258277E+11 | 23173.88 | 02-OCT-08:09 | 0.885613E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.248511E+11 | 23173.88 | 01-NOV-08:09 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.258277E+11 | 23173.88 | 01-DEC-09:09 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.310507E+12 | 0.107336E+12 | ||||
Minimum of Months | 0.236390E+11 | 23173.88 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.273097E+11 | 23173.88 | 0.956462E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3588851.36 | 0.126580E+10 |
February | 0.500553E+09 | 0.233575E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1410819.29 | 0.131286E+10 |
March | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17212.21 | 0.166004E+10 |
April | 0.544079E+09 | 0.252182E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4692874.02 | 0.109556E+10 |
May | 0.565842E+09 | 0.261486E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 63813.31 | 0.120356E+10 |
June | 0.565842E+09 | 0.257569E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1205297.84 | 0.848775E+09 |
July | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30663905.50 | 0.554046E+09 |
August | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31055077.22 | 0.633088E+09 |
September | 0.544079E+09 | 0.252182E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48239272.64 | 0.733776E+09 |
October | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89387806.34 | 0.778020E+09 |
November | 0.522316E+09 | 0.246796E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1361367.09 | 0.122416E+10 |
December | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4751457.57 | 0.121224E+10 |
Annual Sum or Average | 0.659424E+10 | 0.306193E+11 | 0.319458E+11 | 0.216438E+09 | 0.125219E+11 | ||||
Minimum of Months | 0.500553E+09 | 0.233575E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17212.21 | 0.554046E+09 |
Maximum of Months | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 89387806.34 | 0.166004E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18798612.44 | 0.512050E+10 |
February | 0.00 | 0.102778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 68578.64 | 0.640881E+10 |
March | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.770616E+10 |
April | 0.00 | 0.111270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3600749.57 | 0.626065E+10 |
May | 0.00 | 0.115516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.768022E+10 |
June | 0.00 | 0.114492E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.547130E+10 |
July | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7003875.36 | 0.428075E+10 |
August | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4296493.43 | 0.491170E+10 |
September | 0.00 | 0.111270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 96572497.32 | 0.448501E+10 |
October | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242948E+09 | 0.548797E+10 |
November | 0.00 | 0.108048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11318482.77 | 0.580600E+10 |
December | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7719763.68 | 0.554516E+10 |
Annual Sum or Average | 0.135003E+12 | 0.392327E+09 | 0.691642E+11 | ||||||
Minimum of Months | 0.00 | 0.102778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.428075E+10 |
Maximum of Months | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242948E+09 | 0.770616E+10 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.526645E+09 | 0.137623E+11 |
February | 0.00 | 0.236390E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31518244.26 | 0.197896E+11 |
March | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 67010586.50 | 0.236999E+11 |
April | 0.00 | 0.255921E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.131148E+09 | 0.195327E+11 |
May | 0.00 | 0.265687E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.260880E+11 |
June | 0.00 | 0.263332E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.209128E+11 |
July | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.210797E+11 |
August | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231598E+11 |
September | 0.00 | 0.255921E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 76526324.45 | 0.190023E+11 |
October | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568078E+09 | 0.220114E+11 |
November | 0.00 | 0.248511E+11 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135942E+09 | 0.192802E+11 |
December | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.444512E+09 | 0.169645E+11 |
Annual Sum or Average | 0.310507E+12 | 0.107336E+12 | 0.198138E+10 | 0.245283E+12 | |||||
Minimum of Months | 0.00 | 0.236390E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137623E+11 |
Maximum of Months | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.568078E+09 | 0.260880E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 659.25 | 02-JAN-08:09 | 1939.55 | 02-JAN-08:09 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 735.98 | 18-JAN-13:00 | 6898.49 | 09-JAN-07:10 |
February | 659.25 | 01-FEB-08:09 | 1939.55 | 01-FEB-08:09 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 626.11 | 01-FEB-12:10 | 5384.23 | 09-FEB-07:05 |
March | 659.25 | 01-MAR-08:09 | 1939.55 | 01-MAR-08:09 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 11-MAR-14:00 | 6320.07 | 30-MAR-06:05 |
April | 659.25 | 01-APR-07:10 | 1939.55 | 01-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 741.54 | 26-APR-11:10 | 4456.25 | 17-APR-16:05 |
May | 659.25 | 01-MAY-07:10 | 1939.55 | 01-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 34.31 | 04-MAY-12:00 | 4368.97 | 26-MAY-06:03 |
June | 659.25 | 01-JUN-07:10 | 1939.55 | 01-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 332.69 | 29-JUN-11:10 | 3795.70 | 05-JUN-06:02 |
July | 659.25 | 01-JUL-07:10 | 1939.55 | 01-JUL-07:10 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1449.35 | 19-JUL-12:00 | 3231.05 | 17-JUL-06:03 |
August | 659.25 | 01-AUG-07:10 | 1939.55 | 01-AUG-07:10 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1435.76 | 18-AUG-12:00 | 3565.64 | 28-AUG-07:00 |
September | 659.25 | 01-SEP-07:10 | 1939.55 | 01-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4123.49 | 29-SEP-12:00 | 4136.69 | 20-SEP-06:01 |
October | 659.25 | 02-OCT-07:10 | 1939.55 | 02-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4498.53 | 16-OCT-11:10 | 4891.36 | 12-OCT-06:03 |
November | 659.25 | 01-NOV-07:10 | 1939.55 | 01-NOV-07:10 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 73.43 | 19-NOV-13:00 | 5105.45 | 30-NOV-07:10 |
December | 659.25 | 01-DEC-08:09 | 1939.55 | 01-DEC-08:09 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 738.95 | 19-DEC-13:00 | 6039.48 | 22-DEC-07:05 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 | 3231.05 | |||||
Maximum of Months | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 4498.53 | 6898.49 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 10075.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1698.45 | 15-JAN-10:00 | 8703.82 | 27-JAN-05:00 |
February | 0.00 | 10075.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.39 | 01-FEB-12:00 | 9555.55 | 25-FEB-16:05 |
March | 0.00 | 10075.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 13793.25 | 28-MAR-15:05 |
April | 0.00 | 10075.60 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 448.63 | 02-APR-12:00 | 14174.25 | 17-APR-16:25 |
May | 0.00 | 10075.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 12968.88 | 12-MAY-16:00 |
June | 0.00 | 10075.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 8001.76 | 12-JUN-16:00 |
July | 0.00 | 10075.60 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 453.45 | 31-JUL-13:00 | 8115.86 | 20-JUL-17:00 |
August | 0.00 | 10075.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 365.43 | 17-AUG-14:00 | 6340.40 | 21-AUG-17:00 |
September | 0.00 | 10075.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4615.77 | 29-SEP-15:10 | 7658.14 | 02-SEP-15:10 |
October | 0.00 | 10075.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4454.38 | 14-OCT-15:10 | 8690.30 | 23-OCT-15:05 |
November | 0.00 | 10075.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 960.01 | 19-NOV-13:00 | 8772.88 | 30-NOV-07:10 |
December | 0.00 | 10075.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1040.19 | 25-DEC-12:00 | 8921.99 | 13-DEC-08:00 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6340.40 | |||
Maximum of Months | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4615.77 | 14174.25 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 23173.88 | 02-JAN-09:09 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 8725.32 | 14-JAN-11:00 | 25506.11 | 27-JAN-05:00 |
February | 0.00 | 23173.88 | 01-FEB-09:09 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 5518.60 | 01-FEB-12:00 | 32703.91 | 25-FEB-13:05 |
March | 0.00 | 23173.88 | 01-MAR-09:09 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 3695.32 | 11-MAR-13:10 | 38236.71 | 28-MAR-08:00 |
April | 0.00 | 23173.88 | 01-APR-08:09 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6128.91 | 01-APR-12:10 | 40793.29 | 17-APR-16:00 |
May | 0.00 | 23173.88 | 01-MAY-08:09 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 40586.05 | 12-MAY-16:00 |
June | 0.00 | 23173.88 | 01-JUN-08:09 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 23082.44 | 12-JUN-16:00 |
July | 0.00 | 23173.88 | 01-JUL-08:09 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 30065.00 | 20-JUL-09:00 |
August | 0.00 | 23173.88 | 01-AUG-08:09 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 21507.13 | 22-AUG-16:00 |
September | 0.00 | 23173.88 | 01-SEP-08:09 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6805.04 | 29-SEP-10:12 | 27165.55 | 02-SEP-15:00 |
October | 0.00 | 23173.88 | 02-OCT-08:09 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19152.12 | 16-OCT-10:00 | 31356.35 | 07-OCT-08:00 |
November | 0.00 | 23173.88 | 01-NOV-08:09 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 5652.75 | 19-NOV-13:00 | 24950.16 | 01-NOV-08:00 |
December | 0.00 | 23173.88 | 01-DEC-09:09 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 11212.67 | 18-DEC-11:00 | 30997.80 | 12-DEC-13:05 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21507.13 | ||||
Maximum of Months | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 19152.12 | 40793.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3543.90 | 21-JAN-15:30 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 151.21 |
February | 3489.11 | 03-FEB-15:10 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 83.36 |
March | 4424.12 | 23-MAR-15:50 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 227.33 |
April | 17179.97 | 28-APR-05:03 | 217.55 | 1738.04 | 1721.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 675.90 |
May | 17643.28 | 04-MAY-05:03 | 290.07 | 2317.39 | 2295.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 652.33 |
June | 18915.84 | 23-JUN-05:01 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 515.67 |
July | 18358.43 | 10-JUL-05:01 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 485.75 |
August | 17800.92 | 22-AUG-05:02 | 362.59 | 2896.74 | 2868.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 705.22 |
September | 18796.54 | 29-SEP-05:01 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 472.32 |
October | 20662.93 | 17-OCT-05:01 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 629.55 |
November | 3776.94 | 18-NOV-15:30 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.29 |
December | 3762.37 | 05-DEC-15:20 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 27.05 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 3489.11 | 217.55 | 1738.04 | 1721.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 20662.93 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 27.05 | 705.22 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 6898.33 | 24-JAN-07:10 | 0.00 | 7112.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3256.51 |
February | 6851.80 | 28-FEB-07:10 | 0.00 | 7112.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3321.38 |
March | 10043.63 | 10-MAR-07:10 | 0.00 | 7112.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 318.56 |
April | 40753.73 | 30-APR-13:41 | 0.00 | 9482.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1998.58 |
May | 11315.59 | 03-MAY-13:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 787.10 |
June | 41373.20 | 25-JUN-16:31 | 0.00 | 10668.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3030.78 |
July | 43790.65 | 04-JUL-16:51 | 0.00 | 9482.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 39802.35 | 20-AUG-16:31 | 0.00 | 9482.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2763.09 |
September | 38891.32 | 30-SEP-17:11 | 0.00 | 9482.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 119.90 |
October | 37983.74 | 15-OCT-13:43 | 0.00 | 3556.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2605.58 | 0.00 |
November | 8724.45 | 29-NOV-07:10 | 0.00 | 7112.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 7269.94 | 06-DEC-07:10 | 0.00 | 7112.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3806.65 |
Annual Sum or Average | |||||||||||
Minimum of Months | 6851.80 | 0.00 | 3556.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 43790.65 | 0.00 | 10668.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2605.58 | 3806.65 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:05 | 0.00 | 5452.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7831.47 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8462.53 |
April | 0.00 | 01-APR-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12531.43 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8063.52 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6304.48 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5182.92 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7059.57 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7901.33 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 2726.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12345.96 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9568.55 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 2726.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 5452.68 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12531.43 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.666641E+11 | 52843.19 | 13-JAN-16:00 | 0.122289E+10 | 28371.93 | 03-JAN-06:10 |
February | 0.603738E+11 | 51570.59 | 01-FEB-11:00 | 0.358425E+09 | 8469.50 | 28-FEB-06:10 |
March | 0.687700E+11 | 51914.89 | 23-MAR-14:09 | 0.624890E+09 | 18444.61 | 30-MAR-06:10 |
April | 0.642235E+11 | 56287.46 | 26-APR-12:00 | 41962311.00 | 8759.69 | 01-APR-05:10 |
May | 0.660588E+11 | 55093.95 | 04-MAY-12:09 | 3486989.42 | 1618.06 | 15-MAY-06:10 |
June | 0.662990E+11 | 57583.08 | 29-JUN-13:09 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 0.681442E+11 | 63094.09 | 31-JUL-12:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 0.722604E+11 | 62078.61 | 17-AUG-14:20 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 0.662065E+11 | 65052.93 | 29-SEP-12:00 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 0.678581E+11 | 64998.45 | 16-OCT-10:00 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 0.639590E+11 | 52976.98 | 18-NOV-16:49 | 91013946.98 | 5651.78 | 30-NOV-07:10 |
December | 0.668195E+11 | 53299.88 | 05-DEC-16:49 | 0.383338E+09 | 8999.86 | 15-DEC-07:10 |
Annual Sum or Average | 0.797637E+12 | 0.272601E+10 | ||||
Minimum of Months | 0.603738E+11 | 51570.59 | 0.00 | 0.00 | ||
Maximum of Months | 0.722604E+11 | 65052.93 | 0.122289E+10 | 28371.93 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.396181E+11 | 0.977700E+10 | 0.115358E+11 | 0.00 | 0.352533E+10 | 0.00 | 0.00 | 92215090.18 | 0.00 | 0.00 | 0.00 | 0.211566E+10 | 0.00 |
February | 0.362526E+11 | 0.835703E+10 | 0.105871E+11 | 0.00 | 0.322740E+10 | 0.00 | 0.00 | 27082805.84 | 0.00 | 0.00 | 0.00 | 0.192257E+10 | 0.00 |
March | 0.418523E+11 | 0.856529E+10 | 0.123357E+11 | 0.00 | 0.379071E+10 | 0.00 | 0.00 | 63606546.31 | 0.00 | 0.00 | 0.00 | 0.216246E+10 | 0.00 |
April | 0.392410E+11 | 0.761485E+10 | 0.114862E+11 | 0.00 | 0.350770E+10 | 0.00 | 0.00 | 0.330880E+09 | 0.00 | 0.00 | 0.00 | 0.204288E+10 | 0.00 |
May | 0.407352E+11 | 0.727027E+10 | 0.119357E+11 | 0.00 | 0.364587E+10 | 0.00 | 0.00 | 0.375707E+09 | 0.00 | 0.00 | 0.00 | 0.209604E+10 | 0.00 |
June | 0.403581E+11 | 0.674015E+10 | 0.118862E+11 | 0.00 | 0.368123E+10 | 0.00 | 0.00 | 0.160267E+10 | 0.00 | 0.00 | 0.00 | 0.203073E+10 | 0.00 |
July | 0.396181E+11 | 0.709609E+10 | 0.115358E+11 | 0.00 | 0.374286E+10 | 0.00 | 0.00 | 0.411203E+10 | 0.00 | 0.00 | 0.00 | 0.203936E+10 | 0.00 |
August | 0.418523E+11 | 0.759971E+10 | 0.123357E+11 | 0.00 | 0.393357E+10 | 0.00 | 0.00 | 0.445045E+10 | 0.00 | 0.00 | 0.00 | 0.208877E+10 | 0.00 |
September | 0.392410E+11 | 0.800109E+10 | 0.114862E+11 | 0.00 | 0.364774E+10 | 0.00 | 0.00 | 0.182752E+10 | 0.00 | 0.00 | 0.00 | 0.200292E+10 | 0.00 |
October | 0.396181E+11 | 0.896667E+10 | 0.115358E+11 | 0.00 | 0.366249E+10 | 0.00 | 0.00 | 0.201047E+10 | 0.00 | 0.00 | 0.00 | 0.206454E+10 | 0.00 |
November | 0.381239E+11 | 0.928853E+10 | 0.110862E+11 | 0.00 | 0.336413E+10 | 0.00 | 0.00 | 81465368.50 | 0.00 | 0.00 | 0.00 | 0.201472E+10 | 0.00 |
December | 0.396181E+11 | 0.994361E+10 | 0.115358E+11 | 0.00 | 0.350819E+10 | 0.00 | 0.00 | 0.109330E+09 | 0.00 | 0.00 | 0.00 | 0.210444E+10 | 0.00 |
Annual Sum or Average | 0.476129E+12 | 0.992203E+11 | 0.139282E+12 | 0.432372E+11 | 0.00 | 0.150834E+11 | 0.246851E+11 | ||||||
Minimum of Months | 0.362526E+11 | 0.674015E+10 | 0.105871E+11 | 0.00 | 0.322740E+10 | 0.00 | 0.00 | 27082805.84 | 0.00 | 0.00 | 0.00 | 0.192257E+10 | 0.00 |
Maximum of Months | 0.418523E+11 | 0.994361E+10 | 0.123357E+11 | 0.00 | 0.393357E+10 | 0.00 | 0.00 | 0.445045E+10 | 0.00 | 0.00 | 0.00 | 0.216246E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.122289E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.358425E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.624890E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 41962311.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 3486989.42 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 91013946.98 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.383338E+09 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.272601E+10 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.122289E+10 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 35189.04 | 02-JAN-09:09 | 6311.00 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 3539.18 | 10-JAN-07:10 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 35189.04 | 01-FEB-09:09 | 6311.00 | 01-FEB-00:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 3539.18 | 01-FEB-08:09 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 35189.04 | 01-MAR-09:09 | 6311.00 | 01-MAR-00:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 3539.18 | 01-MAR-17:19 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 35189.04 | 01-APR-08:09 | 6311.00 | 01-APR-00:10 | 10112.62 | 01-APR-07:10 | 0.00 | 3539.18 | 08-APR-13:20 | 0.00 | 0.00 | 01-APR-00:10 |
May | 35189.04 | 01-MAY-08:09 | 6311.00 | 01-MAY-00:10 | 10112.62 | 01-MAY-07:10 | 0.00 | 3539.18 | 01-MAY-10:20 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 35189.04 | 01-JUN-08:09 | 6311.00 | 01-JUN-00:10 | 10112.62 | 01-JUN-07:10 | 0.00 | 4115.51 | 29-JUN-10:30 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 35189.04 | 01-JUL-08:09 | 6311.00 | 01-JUL-00:10 | 10112.62 | 01-JUL-07:10 | 0.00 | 5844.48 | 19-JUL-11:20 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 35189.04 | 01-AUG-08:09 | 6311.00 | 01-AUG-00:10 | 10112.62 | 01-AUG-07:10 | 0.00 | 4691.83 | 14-AUG-11:00 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 35189.04 | 01-SEP-08:09 | 6311.00 | 01-SEP-00:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 5844.48 | 29-SEP-10:20 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 35189.04 | 02-OCT-08:09 | 6311.00 | 01-OCT-00:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 5844.48 | 14-OCT-12:50 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 35189.04 | 01-NOV-08:09 | 6311.00 | 01-NOV-00:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 3539.18 | 01-NOV-06:10 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 35189.04 | 01-DEC-09:09 | 6311.00 | 01-DEC-00:10 | 10112.62 | 01-DEC-08:09 | 0.00 | 3539.18 | 01-DEC-07:10 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 35189.04 | 6311.00 | 10112.62 | 0.00 | 3539.18 | 0.00 | 0.00 | |||||
Maximum of Months | 35189.04 | 6311.00 | 10112.62 | 0.00 | 5844.48 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 1115.03 | 24-JAN-15:20 | 0.00 | 0.00 | 0.00 | 1799.13 | 31-JAN-12:39 | 0.00 |
February | 1031.11 | 01-FEB-12:09 | 0.00 | 0.00 | 0.00 | 1799.27 | 07-FEB-12:39 | 0.00 |
March | 1320.55 | 23-MAR-13:00 | 0.00 | 0.00 | 0.00 | 1797.34 | 01-MAR-12:39 | 0.00 |
April | 5697.70 | 26-APR-12:00 | 0.00 | 0.00 | 0.00 | 1791.43 | 01-APR-11:09 | 0.00 |
May | 4505.83 | 04-MAY-12:09 | 0.00 | 0.00 | 0.00 | 1783.29 | 03-MAY-11:30 | 0.00 |
June | 7037.29 | 29-JUN-13:09 | 0.00 | 0.00 | 0.00 | 1775.43 | 01-JUN-11:09 | 0.00 |
July | 10489.44 | 31-JUL-14:20 | 0.00 | 0.00 | 0.00 | 1769.23 | 01-JUL-11:09 | 0.00 |
August | 10560.12 | 17-AUG-13:00 | 0.00 | 0.00 | 0.00 | 1768.59 | 31-AUG-11:09 | 0.00 |
September | 12468.34 | 29-SEP-11:00 | 0.00 | 0.00 | 0.00 | 1773.60 | 29-SEP-11:09 | 0.00 |
October | 12986.24 | 16-OCT-11:09 | 0.00 | 0.00 | 0.00 | 1782.04 | 31-OCT-11:39 | 0.00 |
November | 1210.80 | 18-NOV-13:00 | 0.00 | 0.00 | 0.00 | 1789.63 | 28-NOV-12:50 | 0.00 |
December | 1212.24 | 05-DEC-14:00 | 0.00 | 0.00 | 0.00 | 1796.16 | 29-DEC-12:09 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1031.11 | 0.00 | 0.00 | 0.00 | 1768.59 | 0.00 | ||
Maximum of Months | 12986.24 | 0.00 | 0.00 | 0.00 | 1799.27 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 52843.19 | 13-JAN-16:00 | 31277.33 | 10112.62 | 6311.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 0.02 | 0.00 |
February | 51570.59 | 01-FEB-11:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 1004.53 | 0.00 |
March | 51914.89 | 23-MAR-14:09 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 1317.53 | 0.00 |
April | 56287.46 | 26-APR-12:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 5697.70 | 0.00 |
May | 55093.95 | 04-MAY-12:09 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 4505.83 | 0.00 |
June | 57583.08 | 29-JUN-13:09 | 35189.04 | 10112.62 | 0.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 7037.29 | 0.00 |
July | 63094.09 | 31-JUL-12:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 5844.48 | 0.00 | 0.00 | 10214.25 | 0.00 |
August | 62078.61 | 17-AUG-14:20 | 35189.04 | 10112.62 | 0.00 | 0.00 | 4691.83 | 0.00 | 0.00 | 10350.61 | 0.00 |
September | 65052.93 | 29-SEP-12:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 5844.48 | 0.00 | 0.00 | 12167.10 | 0.00 |
October | 64998.45 | 16-OCT-10:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 5844.48 | 0.00 | 0.00 | 12141.31 | 0.00 |
November | 52976.98 | 18-NOV-16:49 | 31277.33 | 10112.62 | 6311.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 136.57 | 0.00 |
December | 53299.88 | 05-DEC-16:49 | 31277.33 | 10112.62 | 6311.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 458.46 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 51570.59 | 31277.33 | 10112.62 | 0.00 | 0.00 | 3539.18 | 0.00 | 0.00 | 0.02 | 0.00 | |
Maximum of Months | 65052.93 | 35189.04 | 10112.62 | 6311.00 | 0.00 | 5844.48 | 0.00 | 0.00 | 12167.10 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 28371.93 | 03-JAN-06:10 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 8469.50 | 28-FEB-06:10 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 18444.61 | 30-MAR-06:10 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 8759.69 | 01-APR-05:10 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 1618.06 | 15-MAY-06:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 5651.78 | 30-NOV-07:10 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 8999.86 | 15-DEC-07:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 28371.93 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.33 | 20.29 | 2.33 | 20.29 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.50 | 20.47 | 0.50 | 20.47 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 1.50 | 20.42 | 1.50 | 20.42 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.17 | 20.53 | 0.17 | 20.53 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.53 | 0.50 | 24.53 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 24.46 | 0.17 | 24.46 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 24.51 | 1.33 | 24.51 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 24.52 | 0.50 | 24.52 |
November | 0.17 | 20.46 | 0.17 | 20.46 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.50 | 20.48 | 0.50 | 20.48 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 5.17 | 20.38 | 5.17 | 20.38 | 2.50 | 24.51 | 2.50 | 24.51 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.33 | 20.53 | 2.33 | 20.53 | 1.33 | 24.53 | 1.33 | 24.53 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 14.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.31 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 1.50 | 27.27 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.67 | 27.27 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.44 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.17 | 14.96 | 0.00 | 4.00 | 27.33 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 14.96 | 0.00 | 0.00 | 1.50 | 27.44 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 294.67 | 22.90 | 55.50 | 21.21 | 55.50 | 21.21 |
February | 273.83 | 22.99 | 24.50 | 21.16 | 24.50 | 21.16 |
March | 307.17 | 22.89 | 41.00 | 21.63 | 33.50 | 21.12 |
April | 167.17 | 23.37 | 57.33 | 23.72 | 3.67 | 21.14 |
May | 130.00 | 23.52 | 77.00 | 23.89 | 0.00 | 0.00 |
June | 29.50 | 23.61 | 210.33 | 23.89 | 0.00 | 0.00 |
July | 6.00 | 23.80 | 295.33 | 23.90 | 5.00 | 23.93 |
August | 13.67 | 23.86 | 318.33 | 23.90 | 12.83 | 23.91 |
September | 15.17 | 23.69 | 247.83 | 23.90 | 8.17 | 23.90 |
October | 92.50 | 23.60 | 117.00 | 23.90 | 8.50 | 23.92 |
November | 271.00 | 23.31 | 12.33 | 21.26 | 11.83 | 21.15 |
December | 296.67 | 23.15 | 33.83 | 21.21 | 33.83 | 21.21 |
Annual Sum or Average | 1897.33 | 23.15 | 1490.33 | 23.60 | 197.33 | 21.66 |
Minimum of Months | 6.00 | 22.89 | 12.33 | 21.16 | 0.00 | 0.00 |
Maximum of Months | 307.17 | 23.86 | 318.33 | 23.90 | 55.50 | 23.93 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | ||
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.379567E+09 | 92215090.18 | 75.17 | 0.363348E+09 | 16219214.64 | 0.00 | 0.32 | 14-JAN-15:00 | 0.00 | 01-JAN-00:05 | 4645.58 | 24-JAN-15:30 | 4606.41 | 24-JAN-15:20 | 723.97 | 17-JAN-14:00 | 1115.03 | 24-JAN-15:20 | 0.00 | 01-JAN-00:05 |
February | 0.111521E+09 | 27082805.84 | 56.75 | 0.110964E+09 | 557440.36 | 0.00 | 0.30 | 01-FEB-12:10 | 0.00 | 01-FEB-00:10 | 4180.09 | 01-FEB-12:10 | 4180.09 | 01-FEB-12:10 | 226.21 | 01-FEB-13:40 | 1031.11 | 01-FEB-12:10 | 0.00 | 01-FEB-00:10 |
March | 0.264515E+09 | 63606546.31 | 73.92 | 0.225502E+09 | 39013049.51 | 0.00 | 0.36 | 23-MAR-14:00 | 0.00 | 01-MAR-00:10 | 5646.09 | 23-MAR-14:00 | 4340.72 | 23-MAR-14:00 | 1564.97 | 23-MAR-15:00 | 1320.55 | 23-MAR-14:00 | 0.00 | 01-MAR-00:10 |
April | 0.109014E+10 | 0.260187E+09 | 164.20 | 0.894042E+09 | 0.196094E+09 | 0.00 | 1.00 | 27-APR-05:03 | 0.00 | 01-APR-00:10 | 16600.91 | 27-APR-05:03 | 10911.20 | 28-APR-05:03 | 6715.47 | 27-APR-05:03 | 3512.50 | 27-APR-05:03 | 0.00 | 01-APR-00:10 |
May | 0.124413E+10 | 0.296702E+09 | 203.79 | 0.104162E+10 | 0.202509E+09 | 0.00 | 1.00 | 01-MAY-05:03 | 0.00 | 01-MAY-00:10 | 16528.97 | 03-MAY-05:03 | 11150.93 | 04-MAY-05:03 | 7001.68 | 03-MAY-05:03 | 3498.50 | 03-MAY-05:03 | 0.00 | 01-MAY-00:10 |
June | 0.378663E+10 | 0.877450E+09 | 233.59 | 0.285035E+10 | 0.936283E+09 | 0.00 | 1.00 | 03-JUN-05:03 | 0.00 | 01-JUN-00:10 | 17539.41 | 30-JUN-05:01 | 11744.75 | 23-JUN-05:50 | 8131.41 | 28-JUN-05:13 | 3685.51 | 30-JUN-05:01 | 0.00 | 01-JUN-00:10 |
July | 0.692133E+10 | 0.158034E+10 | 253.68 | 0.498446E+10 | 0.193687E+10 | 0.00 | 1.00 | 01-JUL-05:01 | 0.00 | 01-JUL-00:10 | 18098.76 | 29-JUL-05:01 | 12134.66 | 10-JUL-05:01 | 8720.92 | 24-JUL-05:05 | 3780.37 | 29-JUL-05:01 | 0.00 | 01-JUL-00:10 |
August | 0.759183E+10 | 0.172928E+10 | 274.28 | 0.536152E+10 | 0.223031E+10 | 0.00 | 1.00 | 01-AUG-05:01 | 0.00 | 01-AUG-00:10 | 18348.26 | 07-AUG-05:01 | 11493.25 | 30-AUG-05:01 | 9401.07 | 07-AUG-05:13 | 3820.74 | 07-AUG-05:01 | 0.00 | 01-AUG-00:10 |
September | 0.416168E+10 | 0.987559E+09 | 228.18 | 0.312596E+10 | 0.103572E+10 | 0.00 | 1.00 | 01-SEP-05:02 | 0.00 | 01-SEP-00:10 | 17847.91 | 22-SEP-05:01 | 16361.57 | 30-SEP-05:01 | 8235.30 | 23-SEP-05:03 | 3738.58 | 22-SEP-05:01 | 0.00 | 01-SEP-00:10 |
October | 0.398565E+10 | 0.958630E+09 | 235.03 | 0.330545E+10 | 0.680196E+09 | 0.00 | 1.00 | 02-OCT-05:01 | 0.00 | 01-OCT-00:10 | 18671.47 | 05-OCT-05:01 | 15174.50 | 14-OCT-05:25 | 8786.44 | 05-OCT-05:06 | 3871.27 | 05-OCT-05:01 | 0.00 | 01-OCT-00:10 |
November | 0.335985E+09 | 81465368.50 | 106.83 | 0.328074E+09 | 7911213.67 | 0.00 | 0.34 | 18-NOV-14:10 | 0.00 | 01-NOV-00:10 | 4963.00 | 18-NOV-14:30 | 4963.00 | 18-NOV-14:30 | 687.19 | 10-NOV-13:10 | 1210.80 | 18-NOV-14:00 | 0.00 | 01-NOV-00:10 |
December | 0.449810E+09 | 0.109330E+09 | 99.56 | 0.446985E+09 | 2825774.85 | 0.00 | 0.36 | 05-DEC-15:00 | 0.00 | 01-DEC-00:10 | 5022.57 | 05-DEC-15:00 | 5022.57 | 05-DEC-15:00 | 459.41 | 07-DEC-14:00 | 1212.24 | 05-DEC-15:00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.303228E+11 | 0.706385E+10 | 2004.98 | 0.230383E+11 | 0.728450E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.111521E+09 | 27082805.84 | 56.75 | 0.110964E+09 | 557440.36 | 0.00 | 0.30 | 0.00 | 4180.09 | 4180.09 | 226.21 | 1031.11 | 0.00 | |||||||
Maximum of Months | 0.759183E+10 | 0.172928E+10 | 274.28 | 0.536152E+10 | 0.223031E+10 | 0.00 | 1.00 | 0.00 | 18671.47 | 16361.57 | 9401.07 | 3871.27 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 | 0.00 | 01-JAN-00:05 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 | 0.00 | 01-FEB-00:10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 | 0.00 | 01-MAR-00:10 |
April | 0.245068E+09 | 70693162.47 | 30.42 | 0.208767E+09 | 36301088.05 | 0.00 | 1.00 | 30-APR-12:41 | 0.00 | 01-APR-00:10 | 46803.18 | 30-APR-12:41 | 38315.53 | 30-APR-13:41 | 8912.74 | 30-APR-12:49 | 11714.40 | 30-APR-12:41 | 0.00 | 01-APR-00:10 |
May | 0.275316E+09 | 79005322.38 | 37.17 | 0.228909E+09 | 46406518.70 | 0.00 | 0.25 | 04-MAY-12:00 | 0.00 | 01-MAY-00:10 | 10331.82 | 04-MAY-12:00 | 8741.85 | 03-MAY-13:00 | 1769.06 | 04-MAY-12:30 | 2925.57 | 04-MAY-12:00 | 0.00 | 01-MAY-00:10 |
June | 0.260334E+10 | 0.725222E+09 | 113.48 | 0.182028E+10 | 0.783061E+09 | 0.00 | 1.00 | 18-JUN-12:11 | 0.00 | 01-JUN-00:10 | 49368.55 | 29-JUN-17:11 | 36163.73 | 25-JUN-12:32 | 19540.33 | 29-JUN-18:05 | 12176.39 | 29-JUN-17:11 | 0.00 | 01-JUN-00:10 |
July | 0.927186E+10 | 0.253169E+10 | 211.73 | 0.625982E+10 | 0.301204E+10 | 0.00 | 1.00 | 02-JUL-09:31 | 0.00 | 01-JUL-00:10 | 51217.31 | 31-JUL-17:10 | 35358.21 | 04-JUL-09:31 | 22902.61 | 29-JUL-17:15 | 12712.85 | 23-JUL-10:54 | 0.00 | 01-JUL-00:10 |
August | 0.993379E+10 | 0.272117E+10 | 216.88 | 0.658096E+10 | 0.335282E+10 | 0.00 | 1.00 | 06-AUG-09:51 | 0.00 | 01-AUG-00:10 | 51150.43 | 13-AUG-10:22 | 35769.35 | 19-AUG-17:10 | 22678.06 | 18-AUG-17:12 | 12732.04 | 06-AUG-12:52 | 0.00 | 01-AUG-00:10 |
September | 0.278008E+10 | 0.839963E+09 | 126.70 | 0.234314E+10 | 0.436945E+09 | 0.00 | 1.00 | 10-SEP-12:31 | 0.00 | 01-SEP-00:10 | 49181.23 | 10-SEP-13:21 | 38673.89 | 30-SEP-17:11 | 18066.54 | 10-SEP-12:31 | 12141.14 | 10-SEP-13:21 | 0.00 | 01-SEP-00:10 |
October | 0.343386E+10 | 0.105184E+10 | 116.56 | 0.307176E+10 | 0.362102E+09 | 0.00 | 1.00 | 01-OCT-11:01 | 0.00 | 01-OCT-00:10 | 51442.04 | 01-OCT-11:42 | 41205.58 | 15-OCT-13:43 | 21010.14 | 01-OCT-15:20 | 12840.85 | 01-OCT-12:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | 0.285433E+11 | 0.801959E+10 | 852.93 | 0.205136E+11 | 0.802968E+10 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.993379E+10 | 0.272117E+10 | 216.88 | 0.658096E+10 | 0.335282E+10 | 0.00 | 1.00 | 0.00 | 51442.04 | 41205.58 | 22902.61 | 12840.85 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 61.49 | 31.05 | 30.44 | 75.17 | 108.06 | 0.00 | 0.00 | 744.00 |
February | 73.18 | 33.75 | 39.43 | 84.84 | 99.64 | 0.00 | 0.00 | 672.00 |
March | 83.83 | 37.04 | 46.79 | 100.04 | 103.38 | 0.00 | 0.00 | 744.00 |
April | 115.39 | 59.92 | 55.48 | 153.24 | 94.05 | 0.00 | 0.00 | 720.00 |
May | 113.39 | 52.19 | 61.20 | 141.74 | 89.91 | 0.00 | 0.00 | 744.00 |
June | 120.36 | 60.14 | 60.23 | 160.35 | 75.19 | 0.00 | 0.00 | 720.00 |
July | 127.43 | 68.15 | 59.28 | 180.21 | 72.10 | 0.00 | 0.00 | 744.00 |
August | 119.38 | 64.58 | 54.80 | 172.74 | 74.73 | 0.00 | 0.00 | 744.00 |
September | 102.22 | 54.60 | 47.62 | 142.10 | 82.53 | 0.00 | 0.00 | 720.00 |
October | 78.28 | 42.75 | 35.53 | 112.42 | 89.38 | 0.00 | 0.00 | 744.00 |
November | 70.64 | 36.90 | 33.73 | 86.34 | 107.50 | 0.00 | 0.00 | 720.00 |
December | 62.33 | 33.37 | 28.96 | 76.59 | 113.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 94.08 | 47.93 | 46.14 | 124.01 | 92.51 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 61.49 | 31.05 | 28.96 | 75.17 | 72.10 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 127.43 | 68.15 | 61.20 | 180.21 | 113.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 61.49 | 31.05 | 30.44 | 75.17 | 108.06 | 0.00 | 0.00 | 744.00 |
February | 73.18 | 33.75 | 39.43 | 84.84 | 99.64 | 0.00 | 0.00 | 672.00 |
March | 83.83 | 37.04 | 46.79 | 100.04 | 103.38 | 0.00 | 0.00 | 744.00 |
April | 115.39 | 59.92 | 55.48 | 153.24 | 94.05 | 0.00 | 0.00 | 720.00 |
May | 113.39 | 52.19 | 61.20 | 141.74 | 89.91 | 0.00 | 0.00 | 744.00 |
June | 120.36 | 60.14 | 60.23 | 160.35 | 75.19 | 0.00 | 0.00 | 720.00 |
July | 127.43 | 68.15 | 59.28 | 180.21 | 72.10 | 0.00 | 0.00 | 744.00 |
August | 119.38 | 64.58 | 54.80 | 172.74 | 74.73 | 0.00 | 0.00 | 744.00 |
September | 102.22 | 54.60 | 47.62 | 142.10 | 82.53 | 0.00 | 0.00 | 720.00 |
October | 78.28 | 42.75 | 35.53 | 112.42 | 89.38 | 0.00 | 0.00 | 744.00 |
November | 70.64 | 36.90 | 33.73 | 86.34 | 107.50 | 0.00 | 0.00 | 720.00 |
December | 62.33 | 33.37 | 28.96 | 76.59 | 113.96 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 94.08 | 47.93 | 46.14 | 124.01 | 92.51 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 61.49 | 31.05 | 28.96 | 75.17 | 72.10 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 127.43 | 68.15 | 61.20 | 180.21 | 113.96 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.95 | 0.00 | 13.95 | 7.41 | 65.79 | 0.00 | 0.00 | 744.00 |
February | 17.51 | 0.00 | 17.51 | 7.88 | 61.11 | 0.00 | 0.00 | 672.00 |
March | 21.46 | 0.00 | 21.46 | 12.43 | 63.00 | 0.00 | 0.00 | 744.00 |
April | 24.80 | 0.16 | 24.64 | 15.55 | 57.24 | 0.00 | 0.00 | 720.00 |
May | 29.97 | 1.63 | 28.34 | 17.50 | 52.30 | 0.00 | 0.00 | 744.00 |
June | 31.74 | 3.18 | 28.56 | 21.58 | 42.84 | 0.00 | 0.00 | 720.00 |
July | 30.05 | 2.58 | 27.47 | 22.61 | 41.53 | 0.00 | 0.00 | 744.00 |
August | 25.02 | 0.62 | 24.40 | 20.52 | 44.58 | 0.00 | 0.00 | 744.00 |
September | 21.07 | 0.01 | 21.07 | 16.09 | 50.67 | 0.00 | 0.00 | 720.00 |
October | 16.71 | 0.00 | 16.71 | 15.47 | 54.09 | 0.00 | 0.00 | 744.00 |
November | 15.13 | 0.00 | 15.13 | 7.07 | 65.95 | 0.00 | 0.00 | 720.00 |
December | 12.99 | 0.00 | 12.99 | 6.12 | 69.77 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 21.72 | 0.69 | 21.03 | 14.23 | 55.71 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 12.99 | 0.00 | 12.99 | 6.12 | 41.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 31.74 | 3.18 | 28.56 | 22.61 | 69.77 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 13.95 | 0.00 | 13.95 | 7.41 | 65.79 | 0.00 | 0.00 | 744.00 |
February | 17.51 | 0.00 | 17.51 | 7.88 | 61.11 | 0.00 | 0.00 | 672.00 |
March | 21.46 | 0.00 | 21.46 | 12.43 | 63.00 | 0.00 | 0.00 | 744.00 |
April | 24.80 | 0.16 | 24.64 | 15.55 | 57.24 | 0.00 | 0.00 | 720.00 |
May | 29.97 | 1.63 | 28.34 | 17.50 | 52.30 | 0.00 | 0.00 | 744.00 |
June | 31.73 | 3.18 | 28.56 | 21.58 | 42.84 | 0.00 | 0.00 | 720.00 |
July | 30.05 | 2.58 | 27.47 | 22.61 | 41.53 | 0.00 | 0.00 | 744.00 |
August | 25.02 | 0.62 | 24.40 | 20.52 | 44.58 | 0.00 | 0.00 | 744.00 |
September | 21.07 | 0.01 | 21.06 | 16.09 | 50.67 | 0.00 | 0.00 | 720.00 |
October | 16.71 | 0.00 | 16.71 | 15.47 | 54.09 | 0.00 | 0.00 | 744.00 |
November | 15.13 | 0.00 | 15.13 | 7.07 | 65.95 | 0.00 | 0.00 | 720.00 |
December | 12.99 | 0.00 | 12.99 | 6.12 | 69.77 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 21.72 | 0.69 | 21.03 | 14.23 | 55.71 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 12.99 | 0.00 | 12.99 | 6.12 | 41.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 31.73 | 3.18 | 28.56 | 22.61 | 69.77 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 38.95 | 25.43 | 13.52 | 40.32 | 35.55 | 0.17 | 0.00 | 744.00 |
February | 44.91 | 25.15 | 19.76 | 47.88 | 31.95 | 0.00 | 0.00 | 672.00 |
March | 58.72 | 33.32 | 25.39 | 69.54 | 31.00 | 0.00 | 0.00 | 744.00 |
April | 88.46 | 64.17 | 24.29 | 111.18 | 30.30 | 0.00 | 0.00 | 720.00 |
May | 88.36 | 56.71 | 31.65 | 108.41 | 30.07 | 0.00 | 0.00 | 744.00 |
June | 93.89 | 64.56 | 29.33 | 116.64 | 26.59 | 0.00 | 0.00 | 720.00 |
July | 103.01 | 77.12 | 25.89 | 128.22 | 30.38 | 0.00 | 0.00 | 744.00 |
August | 95.32 | 73.01 | 22.31 | 118.57 | 31.67 | 0.00 | 0.00 | 744.00 |
September | 73.21 | 52.05 | 21.16 | 87.99 | 33.10 | 0.00 | 0.00 | 720.00 |
October | 51.98 | 35.86 | 16.11 | 58.47 | 37.79 | 0.00 | 0.00 | 744.00 |
November | 41.70 | 26.52 | 15.18 | 41.84 | 38.78 | 0.00 | 0.00 | 720.00 |
December | 36.05 | 24.24 | 11.81 | 33.43 | 40.68 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 68.00 | 46.63 | 21.37 | 80.37 | 33.18 | 0.17 | 0.00 | 8760.00 |
Minimum of Months | 36.05 | 24.24 | 11.81 | 33.43 | 26.59 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 103.01 | 77.12 | 31.65 | 128.22 | 40.68 | 0.17 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.164704E+09 | 83161027.17 | 81543204.66 | 0.201336E+09 | 0.289429E+09 |
February | 0.177026E+09 | 81641732.75 | 95384754.49 | 0.205256E+09 | 0.241056E+09 |
March | 0.224538E+09 | 99211238.17 | 0.125327E+09 | 0.267934E+09 | 0.276895E+09 |
April | 0.299101E+09 | 0.155309E+09 | 0.143792E+09 | 0.397187E+09 | 0.243771E+09 |
May | 0.303701E+09 | 0.139795E+09 | 0.163907E+09 | 0.379626E+09 | 0.240806E+09 |
June | 0.311985E+09 | 0.155880E+09 | 0.156106E+09 | 0.415625E+09 | 0.194902E+09 |
July | 0.341316E+09 | 0.182529E+09 | 0.158787E+09 | 0.482678E+09 | 0.193122E+09 |
August | 0.319737E+09 | 0.172965E+09 | 0.146773E+09 | 0.462661E+09 | 0.200165E+09 |
September | 0.264966E+09 | 0.141531E+09 | 0.123435E+09 | 0.368313E+09 | 0.213925E+09 |
October | 0.209668E+09 | 0.114507E+09 | 95160416.82 | 0.301112E+09 | 0.239402E+09 |
November | 0.183087E+09 | 95651696.21 | 87435329.09 | 0.223795E+09 | 0.278643E+09 |
December | 0.166939E+09 | 89369873.17 | 77569015.99 | 0.205146E+09 | 0.305219E+09 |
Annual Sum or Average | 0.296677E+10 | 0.151155E+10 | 0.145522E+10 | 0.391067E+10 | 0.291734E+10 |
Minimum of Months | 0.164704E+09 | 81641732.75 | 77569015.99 | 0.201336E+09 | 0.193122E+09 |
Maximum of Months | 0.341316E+09 | 0.182529E+09 | 0.163907E+09 | 0.482678E+09 | 0.305219E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.164704E+09 | 83161027.17 | 81543204.66 | 0.201336E+09 | 0.289429E+09 |
February | 0.177026E+09 | 81641732.75 | 95384754.49 | 0.205256E+09 | 0.241056E+09 |
March | 0.224538E+09 | 99211238.17 | 0.125327E+09 | 0.267934E+09 | 0.276895E+09 |
April | 0.299101E+09 | 0.155309E+09 | 0.143792E+09 | 0.397187E+09 | 0.243771E+09 |
May | 0.303701E+09 | 0.139795E+09 | 0.163907E+09 | 0.379626E+09 | 0.240806E+09 |
June | 0.311985E+09 | 0.155880E+09 | 0.156106E+09 | 0.415625E+09 | 0.194902E+09 |
July | 0.341316E+09 | 0.182529E+09 | 0.158787E+09 | 0.482678E+09 | 0.193122E+09 |
August | 0.319737E+09 | 0.172965E+09 | 0.146773E+09 | 0.462661E+09 | 0.200165E+09 |
September | 0.264966E+09 | 0.141531E+09 | 0.123435E+09 | 0.368313E+09 | 0.213925E+09 |
October | 0.209668E+09 | 0.114507E+09 | 95160416.82 | 0.301112E+09 | 0.239402E+09 |
November | 0.183087E+09 | 95651696.21 | 87435329.09 | 0.223795E+09 | 0.278643E+09 |
December | 0.166939E+09 | 89369873.17 | 77569015.99 | 0.205146E+09 | 0.305219E+09 |
Annual Sum or Average | 0.296677E+10 | 0.151155E+10 | 0.145522E+10 | 0.391067E+10 | 0.291734E+10 |
Minimum of Months | 0.164704E+09 | 81641732.75 | 77569015.99 | 0.201336E+09 | 0.193122E+09 |
Maximum of Months | 0.341316E+09 | 0.182529E+09 | 0.163907E+09 | 0.482678E+09 | 0.305219E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37362038.68 | 0.00 | 37362038.68 | 19840309.56 | 0.176222E+09 |
February | 42360664.79 | 0.00 | 42360664.79 | 19075162.07 | 0.147835E+09 |
March | 57478292.74 | 2044.22 | 57476248.52 | 33300858.73 | 0.168751E+09 |
April | 64282328.51 | 415081.34 | 63867247.17 | 40317149.63 | 0.148360E+09 |
May | 80274667.20 | 4373903.32 | 75900763.88 | 46863121.11 | 0.140088E+09 |
June | 82257438.06 | 8232399.16 | 74025038.89 | 55929060.98 | 0.111035E+09 |
July | 80490241.17 | 6923384.08 | 73566857.09 | 60555277.57 | 0.111227E+09 |
August | 67021876.97 | 1664277.73 | 65357599.24 | 54961497.26 | 0.119404E+09 |
September | 54622769.71 | 21529.06 | 54601240.65 | 41698182.06 | 0.131329E+09 |
October | 44759735.36 | 0.00 | 44759735.36 | 41431512.63 | 0.144879E+09 |
November | 39219397.29 | 0.00 | 39219397.29 | 18329987.04 | 0.170931E+09 |
December | 34780879.84 | 0.00 | 34780879.84 | 16380158.15 | 0.186881E+09 |
Annual Sum or Average | 0.684910E+09 | 21632618.92 | 0.663278E+09 | 0.448682E+09 | 0.175694E+10 |
Minimum of Months | 34780879.84 | 0.00 | 34780879.84 | 16380158.15 | 0.111035E+09 |
Maximum of Months | 82257438.06 | 8232399.16 | 75900763.88 | 60555277.57 | 0.186881E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 37361001.61 | 0.00 | 37361001.61 | 19839586.22 | 0.176221E+09 |
February | 42359404.44 | 0.00 | 42359404.44 | 19074077.91 | 0.147835E+09 |
March | 57476589.15 | 2044.12 | 57474545.02 | 33299110.27 | 0.168750E+09 |
April | 64280718.47 | 415061.89 | 63865656.59 | 40315847.10 | 0.148359E+09 |
May | 80272338.28 | 4373698.31 | 75898639.97 | 46860897.08 | 0.140088E+09 |
June | 82255047.39 | 8232013.30 | 74023034.09 | 55926511.38 | 0.111035E+09 |
July | 80488119.64 | 6923059.58 | 73565060.07 | 60553325.90 | 0.111227E+09 |
August | 67020270.40 | 1664199.72 | 65356070.68 | 54960252.61 | 0.119403E+09 |
September | 54621373.68 | 21528.05 | 54599845.62 | 41696891.28 | 0.131328E+09 |
October | 44758538.18 | 0.00 | 44758538.18 | 41430513.25 | 0.144878E+09 |
November | 39218295.25 | 0.00 | 39218295.25 | 18329173.14 | 0.170930E+09 |
December | 34779932.83 | 0.00 | 34779932.83 | 16379732.52 | 0.186880E+09 |
Annual Sum or Average | 0.684892E+09 | 21631604.97 | 0.663260E+09 | 0.448666E+09 | 0.175693E+10 |
Minimum of Months | 34779932.83 | 0.00 | 34779932.83 | 16379732.52 | 0.111035E+09 |
Maximum of Months | 82255047.39 | 8232013.30 | 75898639.97 | 60553325.90 | 0.186880E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.104334E+09 | 68124352.13 | 36209610.91 | 0.108004E+09 | 95219977.38 |
February | 0.108645E+09 | 60835959.94 | 47808837.27 | 0.115835E+09 | 77292976.44 |
March | 0.157273E+09 | 89255104.24 | 68017655.75 | 0.186250E+09 | 83023037.79 |
April | 0.229296E+09 | 0.166340E+09 | 62956786.04 | 0.288188E+09 | 78544227.87 |
May | 0.236670E+09 | 0.151900E+09 | 84769093.67 | 0.290379E+09 | 80538195.13 |
June | 0.243364E+09 | 0.167343E+09 | 76021360.18 | 0.302331E+09 | 68925318.97 |
July | 0.275895E+09 | 0.206563E+09 | 69331917.55 | 0.343433E+09 | 81367347.55 |
August | 0.255309E+09 | 0.195555E+09 | 59754016.85 | 0.317578E+09 | 84830850.21 |
September | 0.189758E+09 | 0.134902E+09 | 54855397.49 | 0.228078E+09 | 85792006.69 |
October | 0.139219E+09 | 96060659.84 | 43158666.56 | 0.156606E+09 | 0.101223E+09 |
November | 0.108082E+09 | 68735001.79 | 39347082.36 | 0.108443E+09 | 0.100520E+09 |
December | 96548470.85 | 64913624.05 | 31634846.80 | 89552034.56 | 0.108953E+09 |
Annual Sum or Average | 0.214439E+10 | 0.147053E+10 | 0.673865E+09 | 0.253468E+10 | 0.104623E+10 |
Minimum of Months | 96548470.85 | 60835959.94 | 31634846.80 | 89552034.56 | 68925318.97 |
Maximum of Months | 0.275895E+09 | 0.206563E+09 | 84769093.67 | 0.343433E+09 | 0.108953E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 160.32 | 342.87 | 150.89 | 62.10 | 88.79 | 0.00 | 0.00 |
February | 180.19 | 316.24 | 181.37 | 67.49 | 113.88 | 0.00 | 0.00 |
March | 220.00 | 327.84 | 210.58 | 74.08 | 136.50 | 0.00 | 0.00 |
April | 333.12 | 298.11 | 280.39 | 120.16 | 160.23 | 0.00 | 0.00 |
May | 316.34 | 282.30 | 286.72 | 107.65 | 179.07 | 0.00 | 0.00 |
June | 362.11 | 234.32 | 304.20 | 126.63 | 177.57 | 0.00 | 0.00 |
July | 403.59 | 225.21 | 314.97 | 141.47 | 173.50 | 0.00 | 0.00 |
August | 383.92 | 236.03 | 288.80 | 130.40 | 158.40 | 0.00 | 0.00 |
September | 311.68 | 261.72 | 246.60 | 109.22 | 137.37 | 0.00 | 0.00 |
October | 252.13 | 283.29 | 189.98 | 85.50 | 104.48 | 0.00 | 0.00 |
November | 180.77 | 340.84 | 171.53 | 73.81 | 97.73 | 0.00 | 0.00 |
December | 159.93 | 361.97 | 150.63 | 66.73 | 83.89 | 0.00 | 0.00 |
Annual Sum or Average | 272.49 | 292.46 | 231.59 | 97.23 | 134.35 | 0.00 | 0.00 |
Minimum of Months | 159.93 | 225.21 | 150.63 | 62.10 | 83.89 | 0.00 | 0.00 |
Maximum of Months | 403.59 | 361.97 | 314.97 | 141.47 | 179.07 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 403.24 | 355.51 | 389.54 | 254.35 | 135.19 | 0.00 | 0.00 |
February | 478.81 | 319.50 | 449.09 | 251.47 | 197.62 | 0.00 | 0.00 |
March | 695.38 | 309.97 | 587.19 | 333.24 | 253.95 | 0.00 | 0.00 |
April | 1111.84 | 303.03 | 884.63 | 641.74 | 242.89 | 0.00 | 0.00 |
May | 1084.15 | 300.70 | 883.62 | 567.13 | 316.49 | 0.00 | 0.00 |
June | 1166.40 | 265.91 | 938.91 | 645.61 | 293.29 | 0.00 | 0.00 |
July | 1282.23 | 303.79 | 1030.07 | 771.22 | 258.86 | 0.00 | 0.00 |
August | 1185.70 | 316.72 | 953.22 | 730.12 | 223.10 | 0.00 | 0.00 |
September | 879.93 | 330.99 | 732.09 | 520.46 | 211.63 | 0.00 | 0.00 |
October | 584.70 | 377.92 | 519.79 | 358.65 | 161.14 | 0.00 | 0.00 |
November | 418.38 | 387.81 | 416.98 | 265.18 | 151.80 | 0.00 | 0.00 |
December | 334.35 | 406.78 | 360.47 | 242.36 | 118.11 | 0.00 | 0.00 |
Annual Sum or Average | 803.74 | 331.76 | 679.98 | 466.30 | 213.68 | 0.00 | 0.00 |
Minimum of Months | 334.35 | 265.91 | 360.47 | 242.36 | 118.11 | 0.00 | 0.00 |
Maximum of Months | 1282.23 | 406.78 | 1030.07 | 771.22 | 316.49 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.429400E+09 | 0.918350E+09 | 0.404132E+09 | 0.166322E+09 | 0.237809E+09 | 0.00 | 0.00 |
February | 0.435920E+09 | 0.765040E+09 | 0.438773E+09 | 0.163283E+09 | 0.275490E+09 | 0.00 | 0.00 |
March | 0.589260E+09 | 0.878083E+09 | 0.564031E+09 | 0.198427E+09 | 0.365604E+09 | 0.00 | 0.00 |
April | 0.863453E+09 | 0.772708E+09 | 0.726765E+09 | 0.311449E+09 | 0.415316E+09 | 0.00 | 0.00 |
May | 0.847295E+09 | 0.756106E+09 | 0.767950E+09 | 0.288337E+09 | 0.479612E+09 | 0.00 | 0.00 |
June | 0.938585E+09 | 0.607354E+09 | 0.788483E+09 | 0.328223E+09 | 0.460259E+09 | 0.00 | 0.00 |
July | 0.108097E+10 | 0.603204E+09 | 0.843611E+09 | 0.378905E+09 | 0.464706E+09 | 0.00 | 0.00 |
August | 0.102829E+10 | 0.632180E+09 | 0.773517E+09 | 0.349258E+09 | 0.424259E+09 | 0.00 | 0.00 |
September | 0.807882E+09 | 0.678368E+09 | 0.639175E+09 | 0.283104E+09 | 0.356071E+09 | 0.00 | 0.00 |
October | 0.675295E+09 | 0.758772E+09 | 0.508854E+09 | 0.229015E+09 | 0.279839E+09 | 0.00 | 0.00 |
November | 0.468552E+09 | 0.883450E+09 | 0.444612E+09 | 0.191303E+09 | 0.253308E+09 | 0.00 | 0.00 |
December | 0.428361E+09 | 0.969510E+09 | 0.403439E+09 | 0.178740E+09 | 0.224699E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.859326E+10 | 0.922313E+10 | 0.730334E+10 | 0.306637E+10 | 0.423697E+10 | 0.00 | 0.00 |
Minimum of Months | 0.428361E+09 | 0.603204E+09 | 0.403439E+09 | 0.163283E+09 | 0.224699E+09 | 0.00 | 0.00 |
Maximum of Months | 0.108097E+10 | 0.969510E+09 | 0.843611E+09 | 0.378905E+09 | 0.479612E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.108004E+10 | 0.952200E+09 | 0.104334E+10 | 0.681244E+09 | 0.362096E+09 | 0.00 | 0.00 |
February | 0.115834E+10 | 0.772930E+09 | 0.108645E+10 | 0.608360E+09 | 0.478088E+09 | 0.00 | 0.00 |
March | 0.186250E+10 | 0.830230E+09 | 0.157273E+10 | 0.892551E+09 | 0.680177E+09 | 0.00 | 0.00 |
April | 0.288188E+10 | 0.785441E+09 | 0.229296E+10 | 0.166340E+10 | 0.629568E+09 | 0.00 | 0.00 |
May | 0.290379E+10 | 0.805382E+09 | 0.236670E+10 | 0.151900E+10 | 0.847691E+09 | 0.00 | 0.00 |
June | 0.302331E+10 | 0.689251E+09 | 0.243364E+10 | 0.167343E+10 | 0.760214E+09 | 0.00 | 0.00 |
July | 0.343433E+10 | 0.813673E+09 | 0.275895E+10 | 0.206563E+10 | 0.693319E+09 | 0.00 | 0.00 |
August | 0.317578E+10 | 0.848307E+09 | 0.255309E+10 | 0.195555E+10 | 0.597540E+09 | 0.00 | 0.00 |
September | 0.228078E+10 | 0.857920E+09 | 0.189758E+10 | 0.134902E+10 | 0.548554E+09 | 0.00 | 0.00 |
October | 0.156606E+10 | 0.101223E+10 | 0.139219E+10 | 0.960607E+09 | 0.431587E+09 | 0.00 | 0.00 |
November | 0.108443E+10 | 0.100520E+10 | 0.108082E+10 | 0.687350E+09 | 0.393471E+09 | 0.00 | 0.00 |
December | 0.895520E+09 | 0.108953E+10 | 0.965485E+09 | 0.649136E+09 | 0.316348E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.253468E+11 | 0.104623E+11 | 0.214439E+11 | 0.147053E+11 | 0.673865E+10 | 0.00 | 0.00 |
Minimum of Months | 0.895520E+09 | 0.689251E+09 | 0.965485E+09 | 0.608360E+09 | 0.316348E+09 | 0.00 | 0.00 |
Maximum of Months | 0.343433E+10 | 0.108953E+10 | 0.275895E+10 | 0.206563E+10 | 0.847691E+09 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 13.22 | 9.60 | 5.99 | 2.23 | 0.81 | 45.19 | 208.20 | 0.00 |
February | 13.28 | 10.19 | 7.03 | 3.12 | 2.95 | 66.07 | 175.60 | 0.04 |
March | 12.64 | 10.60 | 8.97 | 2.93 | 3.55 | 84.90 | 179.28 | 0.03 |
April | 15.30 | 12.61 | 10.61 | 2.62 | 4.75 | 81.20 | 282.81 | 0.02 |
May | 15.56 | 12.64 | 10.56 | 2.92 | 6.16 | 105.80 | 234.18 | 0.01 |
June | 17.67 | 14.80 | 13.02 | 2.53 | 9.02 | 98.05 | 261.27 | 0.00 |
July | 19.43 | 16.75 | 15.28 | 2.35 | 9.62 | 86.54 | 312.15 | 0.00 |
August | 19.66 | 17.23 | 15.95 | 2.55 | 9.61 | 74.58 | 307.55 | 0.00 |
September | 18.47 | 15.49 | 13.65 | 2.19 | 8.98 | 70.75 | 240.05 | 0.00 |
October | 18.77 | 13.71 | 9.60 | 2.71 | 7.73 | 53.88 | 216.36 | 0.00 |
November | 14.32 | 10.42 | 6.22 | 2.47 | 2.40 | 50.75 | 207.87 | 0.01 |
December | 13.59 | 8.80 | 3.19 | 2.50 | 0.04 | 39.49 | 221.83 | 0.00 |
Annual Sum or Average | 16.01 | 12.75 | 10.02 | 2.59 | 5.48 | 71.44 | 237.65 | 0.01 |
Minimum of Months | 12.64 | 8.80 | 3.19 | 2.19 | 0.04 | 39.49 | 175.60 | 0.00 |
Maximum of Months | 19.66 | 17.23 | 15.95 | 3.12 | 9.62 | 105.80 | 312.15 | 0.04 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 26.00 | 13-JAN-13:00 | 15.44 | 8.00 | 3.10 | 11.84 | 120.00 | 725.00 |
February | 26.00 | 01-FEB-11:00 | 14.65 | 6.00 | 4.10 | 10.11 | 166.00 | 715.50 |
March | 24.00 | 11-MAR-10:00 | 13.80 | 6.00 | 2.60 | 8.15 | 120.00 | 907.00 |
April | 27.00 | 26-APR-12:00 | 17.11 | 11.00 | 4.10 | 12.22 | 159.00 | 884.00 |
May | 24.00 | 03-MAY-11:00 | 15.03 | 9.00 | 4.10 | 12.98 | 187.00 | 842.50 |
June | 25.00 | 29-JUN-10:00 | 19.58 | 17.00 | 4.60 | 11.65 | 177.50 | 829.00 |
July | 28.00 | 19-JUL-10:00 | 20.48 | 17.00 | 3.60 | 14.65 | 173.00 | 813.00 |
August | 28.00 | 14-AUG-10:00 | 21.18 | 18.00 | 3.60 | 14.84 | 148.00 | 840.00 |
September | 36.00 | 29-SEP-10:00 | 17.88 | 5.00 | 3.60 | 19.35 | 159.50 | 790.00 |
October | 37.00 | 16-OCT-10:00 | 17.83 | 4.00 | 5.70 | 20.05 | 122.00 | 871.50 |
November | 27.00 | 19-NOV-12:00 | 14.94 | 6.00 | 4.10 | 11.07 | 128.50 | 796.00 |
December | 26.00 | 05-DEC-09:00 | 13.06 | 1.00 | 3.60 | 8.94 | 75.50 | 857.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 24.00 | 13.06 | 1.00 | 2.60 | 8.15 | 75.50 | 715.50 | |
Maximum of Months | 37.00 | 21.18 | 18.00 | 5.70 | 20.05 | 187.00 | 907.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 1.00 | 08-JAN-06:00 | -0.2 | -2.0 | 3.10 | -15.5 | 11.50 | 193.50 |
February | 5.00 | 04-FEB-05:00 | 0.20 | -8.0 | 4.10 | -10.9 | 0.00 | 0.00 |
March | 4.00 | 07-MAR-04:00 | 3.53 | 3.00 | 0.00 | -11.4 | 0.00 | 0.00 |
April | 7.00 | 01-APR-05:00 | 4.32 | 1.00 | 4.10 | -9.0 | 23.50 | 211.00 |
May | 8.00 | 14-MAY-03:00 | 7.45 | 7.00 | 1.50 | -6.6 | 0.00 | 0.00 |
June | 11.00 | 13-JUN-03:00 | 9.85 | 9.00 | 2.10 | -3.4 | 0.00 | 0.00 |
July | 13.00 | 06-JUL-00:00 | 13.00 | 13.00 | 0.00 | -0.6 | 0.00 | 0.00 |
August | 14.00 | 24-AUG-01:00 | 14.00 | 14.00 | 0.00 | 0.51 | 0.00 | 0.00 |
September | 11.00 | 20-SEP-02:00 | 9.85 | 9.00 | 1.50 | -3.4 | 0.00 | 0.00 |
October | 9.00 | 12-OCT-04:00 | 6.55 | 4.00 | 3.10 | -6.4 | 0.00 | 0.00 |
November | 7.00 | 05-NOV-01:00 | 5.53 | 4.00 | 3.10 | -8.3 | 0.00 | 0.00 |
December | 5.00 | 03-DEC-00:00 | 5.00 | 5.00 | 2.10 | -0.4 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.00 | -0.2 | -8.0 | 0.00 | -15.5 | 0.00 | 0.00 | |
Maximum of Months | 14.00 | 14.00 | 14.00 | 4.10 | 0.51 | 23.50 | 211.00 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 17.02 | 17-JAN-11:00 | 24.00 | 13.00 | 3.10 | 12.79 | 223.50 | 9.00 |
February | 16.80 | 11-FEB-13:00 | 18.00 | 16.20 | 1.10 | 15.02 | 241.00 | 12.50 |
March | 17.40 | 22-MAR-12:00 | 22.00 | 15.00 | 3.10 | 8.35 | 145.50 | 876.00 |
April | 18.31 | 26-APR-10:00 | 26.00 | 14.00 | 4.10 | 12.03 | 141.50 | 915.50 |
May | 16.69 | 05-MAY-14:00 | 18.00 | 16.00 | 5.10 | 8.74 | 303.50 | 269.00 |
June | 19.58 | 29-JUN-10:00 | 25.00 | 17.00 | 4.60 | 11.65 | 177.50 | 829.00 |
July | 21.18 | 19-JUL-11:00 | 28.00 | 18.00 | 4.60 | 14.84 | 182.50 | 808.00 |
August | 21.18 | 18-AUG-11:00 | 28.00 | 18.00 | 3.60 | 17.21 | 244.00 | 667.50 |
September | 21.84 | 22-SEP-11:00 | 26.00 | 20.00 | 2.60 | 20.05 | 284.00 | 21.00 |
October | 21.08 | 01-OCT-11:00 | 26.00 | 19.00 | 3.60 | 13.16 | 102.00 | 899.50 |
November | 16.52 | 10-NOV-12:00 | 21.00 | 14.00 | 5.10 | 7.15 | 131.00 | 808.50 |
December | 15.63 | 07-DEC-12:00 | 20.00 | 13.00 | 5.10 | 5.94 | 89.00 | 868.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 15.63 | 18.00 | 13.00 | 1.10 | 5.94 | 89.00 | 9.00 | |
Maximum of Months | 21.84 | 28.00 | 20.00 | 5.10 | 20.05 | 303.50 | 915.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 14.00 | 17-JAN-12:00 | 22.00 | 16.84 | 2.10 | 11.65 | 241.50 | 67.50 |
February | 16.20 | 11-FEB-13:00 | 18.00 | 16.80 | 1.10 | 15.02 | 241.00 | 12.50 |
March | 15.00 | 23-MAR-15:20 | 21.67 | 17.33 | 3.77 | 8.01 | 112.00 | 809.83 |
April | 15.00 | 26-APR-21:19 | 16.00 | 15.39 | 2.23 | 6.02 | 0.00 | 0.00 |
May | 16.00 | 05-MAY-14:00 | 18.00 | 16.69 | 5.10 | 8.74 | 303.50 | 269.00 |
June | 17.00 | 28-JUN-08:00 | 19.00 | 17.66 | 1.50 | 16.12 | 285.00 | 428.50 |
July | 18.00 | 18-JUL-10:00 | 26.00 | 20.46 | 4.60 | 12.79 | 169.00 | 819.00 |
August | 18.10 | 14-AUG-09:00 | 26.90 | 20.91 | 3.40 | 13.73 | 139.00 | 817.00 |
September | 20.00 | 22-SEP-09:00 | 22.00 | 20.55 | 1.50 | 16.30 | 296.00 | 18.00 |
October | 19.00 | 01-OCT-07:10 | 19.17 | 19.06 | 0.25 | 16.82 | 53.33 | 0.00 |
November | 15.00 | 10-NOV-17:19 | 16.67 | 15.62 | 2.77 | 3.34 | 0.00 | 0.00 |
December | 13.00 | 07-DEC-12:00 | 20.00 | 15.63 | 5.10 | 5.94 | 89.00 | 868.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 13.00 | 16.00 | 15.39 | 0.25 | 3.34 | 0.00 | 0.00 | |
Maximum of Months | 20.00 | 26.90 | 20.91 | 5.10 | 16.82 | 303.50 | 868.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 17.43 | 27.46 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 17.38 | 30.87 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 17.83 | 38.09 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 18.69 | 55.75 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 19.73 | 55.13 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 20.65 | 58.21 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 21.22 | 63.49 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 21.28 | 59.02 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 20.81 | 46.26 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 19.94 | 34.64 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 18.91 | 29.25 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 17.99 | 26.27 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 19.33 | 43.77 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 17.38 | 26.27 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 21.28 | 63.49 | 0.00 |
Report: WaterHeaterReportMonthly
For: ELECTRIC TANK
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.822071E+09 | -742376130.6 | 0.00 | 0.00 | 744.00 | 0.00 | -79695343.8 | 59.00 | 0.00 | 0.00 |
February | 0.754285E+09 | -682806835.3 | 0.00 | 0.00 | 672.00 | 0.00 | -71478058.0 | 58.99 | 0.00 | 0.00 |
March | 0.868279E+09 | -789369261.2 | 0.00 | 0.00 | 744.00 | 0.00 | -78909601.7 | 58.99 | 0.00 | 0.00 |
April | 0.791003E+09 | -718021105.9 | 0.00 | 0.00 | 720.00 | 0.00 | -72982336.3 | 58.99 | 0.00 | 0.00 |
May | 0.802099E+09 | -727626718.4 | 0.00 | 0.00 | 744.00 | 0.00 | -74471986.1 | 58.99 | 0.00 | 0.00 |
June | 0.778834E+09 | -708292541.4 | 0.00 | 0.00 | 720.00 | 0.00 | -70541492.2 | 58.99 | 0.00 | 0.00 |
July | 0.745751E+09 | -674425853.5 | 0.00 | 0.00 | 744.00 | 0.00 | -71324956.0 | 58.99 | 0.00 | 0.00 |
August | 0.795157E+09 | -723275742.3 | 0.00 | 0.00 | 744.00 | 0.00 | -71881554.1 | 58.99 | 0.00 | 0.00 |
September | 0.750772E+09 | -680511538.0 | 0.00 | 0.00 | 720.00 | 0.00 | -70260826.3 | 58.99 | 0.00 | 0.00 |
October | 0.770886E+09 | -697687385.6 | 0.00 | 0.00 | 744.00 | 0.00 | -73198536.9 | 58.99 | 0.00 | 0.00 |
November | 0.762398E+09 | -687595034.6 | 0.00 | 0.00 | 720.00 | 0.00 | -74802671.3 | 58.99 | 0.00 | 0.00 |
December | 0.810808E+09 | -732058142.6 | 0.00 | 0.00 | 744.00 | 0.00 | -78749530.1 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.945234E+10 | -.856405E+10 | 8760.00 | -888296892.9 | 58.99 | |||||
Minimum of Months | 0.745751E+09 | -789369261.2 | 0.00 | 0.00 | 672.00 | 0.00 | -79695343.8 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.868279E+09 | -674425853.5 | 0.00 | 0.00 | 744.00 | 0.00 | -70260826.3 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 293.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 279.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 338.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 358.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 393.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 381.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 408.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 390.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 328.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 296.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 300.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 297.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 4065.67 | ||||||||||
Minimum of Months | 279.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 408.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.516936E+09 | 24520.99 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.241080E+09 | 24520.99 | 10-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.414681E+09 | 24520.99 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 28224970.34 | 24520.99 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2249117.48 | 1129.98 | 15-MAY-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 60023324.99 | 15005.94 | 27-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.258248E+09 | 24520.99 | 13-DEC-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.152144E+10 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.516936E+09 | 24520.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.316753E+09 | 59176.13 | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 9037847.02 | 13285.32 | 30-MAR-04:35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.325791E+09 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.316753E+09 | 59176.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATERHEATINGCOIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.379567E+09 | 0.363348E+09 | 4645.58 | 24-JAN-15:30 | 4601.41 | 0.00 |
February | 0.00 | 0.00 | 0.111521E+09 | 0.110964E+09 | 4180.09 | 01-FEB-12:10 | 4180.09 | 0.00 |
March | 0.00 | 0.00 | 0.264515E+09 | 0.225502E+09 | 5646.09 | 23-MAR-14:00 | 4340.72 | 0.00 |
April | 0.00 | 0.00 | 0.109014E+10 | 0.894042E+09 | 16600.91 | 27-APR-05:03 | 9885.44 | 0.00 |
May | 0.00 | 0.00 | 0.124413E+10 | 0.104162E+10 | 16528.97 | 03-MAY-05:03 | 9527.28 | 0.00 |
June | 0.00 | 0.00 | 0.378663E+10 | 0.285035E+10 | 17539.41 | 30-JUN-05:01 | 9874.06 | 0.00 |
July | 0.00 | 0.00 | 0.692133E+10 | 0.498446E+10 | 18098.76 | 29-JUL-05:01 | 9534.66 | 0.00 |
August | 0.00 | 0.00 | 0.759183E+10 | 0.536152E+10 | 18348.26 | 07-AUG-05:01 | 9105.75 | 0.00 |
September | 0.00 | 0.00 | 0.416168E+10 | 0.312596E+10 | 17847.91 | 22-SEP-05:01 | 9724.33 | 0.00 |
October | 0.00 | 0.00 | 0.398565E+10 | 0.330545E+10 | 18671.47 | 05-OCT-05:01 | 10053.00 | 0.00 |
November | 0.00 | 0.00 | 0.335985E+09 | 0.328074E+09 | 4963.00 | 18-NOV-14:30 | 4963.00 | 0.00 |
December | 0.00 | 0.00 | 0.449810E+09 | 0.446985E+09 | 5022.57 | 05-DEC-15:00 | 5022.57 | 0.00 |
Annual Sum or Average | 0.303228E+11 | 0.230383E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.111521E+09 | 0.110964E+09 | 4180.09 | 4180.09 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.759183E+10 | 0.536152E+10 | 18671.47 | 10053.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.245068E+09 | 0.208767E+09 | 46803.18 | 30-APR-12:41 | 38053.91 | 0.00 |
May | 0.00 | 0.00 | 0.275316E+09 | 0.228909E+09 | 10331.82 | 04-MAY-12:00 | 8622.84 | 0.00 |
June | 0.00 | 0.00 | 0.260334E+10 | 0.182028E+10 | 49368.55 | 29-JUN-17:11 | 31485.00 | 0.00 |
July | 0.00 | 0.00 | 0.927186E+10 | 0.625982E+10 | 51217.31 | 31-JUL-17:10 | 30685.20 | 0.00 |
August | 0.00 | 0.00 | 0.993379E+10 | 0.658096E+10 | 51150.43 | 13-AUG-10:22 | 31061.33 | 0.00 |
September | 0.00 | 0.00 | 0.278008E+10 | 0.234314E+10 | 49181.23 | 10-SEP-13:21 | 31546.12 | 0.00 |
October | 0.00 | 0.00 | 0.343386E+10 | 0.307176E+10 | 51442.04 | 01-OCT-11:42 | 31669.65 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 |
Annual Sum or Average | 0.285433E+11 | 0.205136E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.993379E+10 | 0.658096E+10 | 51442.04 | 38053.91 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATERFAN
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.00 | 0.00 | 0.00 | 01-JAN-00:05 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.113142E+10 | 0.36 | 1134.06 | 02-JAN-08:20 | 0.95 |
February | 0.103681E+10 | 0.37 | 1134.06 | 02-FEB-10:30 | 0.95 |
March | 0.121889E+10 | 0.39 | 1134.06 | 03-MAR-15:20 | 0.95 |
April | 0.112412E+10 | 0.36 | 1134.06 | 01-APR-13:50 | 0.95 |
May | 0.116956E+10 | 0.36 | 1134.06 | 01-MAY-09:00 | 0.95 |
June | 0.118405E+10 | 0.38 | 1134.06 | 01-JUN-08:15 | 0.94 |
July | 0.116291E+10 | 0.36 | 1134.06 | 01-JUL-06:50 | 0.94 |
August | 0.125089E+10 | 0.39 | 1134.06 | 01-AUG-06:05 | 0.94 |
September | 0.114318E+10 | 0.37 | 1134.06 | 01-SEP-16:20 | 0.94 |
October | 0.113738E+10 | 0.36 | 1134.06 | 07-OCT-07:50 | 0.95 |
November | 0.107831E+10 | 0.35 | 1134.06 | 01-NOV-08:25 | 0.95 |
December | 0.112712E+10 | 0.36 | 1134.06 | 02-DEC-13:00 | 0.95 |
Annual Sum or Average | 0.137646E+11 | 0.37 | |||
Minimum of Months | 0.103681E+10 | 0.35 | 1134.06 | 0.94 | |
Maximum of Months | 0.125089E+10 | 0.39 | 1134.06 | 0.95 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.239391E+10 | 0.35 | 2405.12 | 02-JAN-07:05 | 0.91 |
February | 0.219059E+10 | 0.34 | 2405.12 | 01-FEB-07:10 | 0.91 |
March | 0.257182E+10 | 0.36 | 2405.12 | 01-MAR-07:10 | 0.91 |
April | 0.238358E+10 | 0.35 | 2405.12 | 08-APR-13:20 | 0.91 |
May | 0.247631E+10 | 0.35 | 2405.12 | 01-MAY-10:20 | 0.91 |
June | 0.249605E+10 | 0.36 | 2405.12 | 02-JUN-10:20 | 0.91 |
July | 0.253734E+10 | 0.36 | 2405.12 | 01-JUL-07:20 | 0.90 |
August | 0.264326E+10 | 0.37 | 2405.12 | 01-AUG-10:10 | 0.90 |
September | 0.238964E+10 | 0.35 | 2405.12 | 01-SEP-10:00 | 0.91 |
October | 0.240854E+10 | 0.34 | 2405.12 | 02-OCT-08:40 | 0.90 |
November | 0.228583E+10 | 0.33 | 2405.12 | 01-NOV-06:03 | 0.91 |
December | 0.238107E+10 | 0.34 | 2405.12 | 01-DEC-07:03 | 0.91 |
Annual Sum or Average | 0.291579E+11 | 0.35 | |||
Minimum of Months | 0.219059E+10 | 0.33 | 2405.12 | 0.90 | |
Maximum of Months | 0.264326E+10 | 0.37 | 2405.12 | 0.91 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 1.54 | 2.06 |
February | 1.51 | 1.45 |
March | 1.36 | 2.02 |
April | 1.53 | 3.55 |
May | 1.39 | 1.80 |
June | 2.25 | 0.43 |
July | 4.14 | 0.22 |
August | 3.89 | 0.23 |
September | 2.92 | 0.27 |
October | 1.71 | 0.94 |
November | 1.33 | 4.05 |
December | 1.68 | 1.83 |
Annual Sum or Average | 25.25 | 1.18 |
Minimum of Months | 1.33 | 0.22 |
Maximum of Months | 4.14 | 4.05 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.08 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.72 | 0.00 |
July | 5.29 | 0.00 |
August | 2.52 | 0.00 |
September | 0.31 | 0.00 |
October | 0.59 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 9.51 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 5.29 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.17 | 0.00 |
October | 0.21 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.38 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.21 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.122363E+10 | 0.751842E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.106390E+10 | 0.358425E+09 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.128250E+10 | 0.611240E+09 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.138431E+10 | 41962311.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.146626E+10 | 3486989.42 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.206150E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.274325E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.298017E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.213074E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.209601E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.115977E+10 | 91013946.98 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.123645E+10 | 0.383338E+09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.208285E+11 | 0.224131E+10 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.106390E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.298017E+10 | 0.751842E+09 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.239391E+10 | 0.471048E+09 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.219059E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.257182E+10 | 13650014.53 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.245427E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.255532E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.322127E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.506903E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.536443E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.322960E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.346037E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.228583E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.238107E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.371775E+11 | 0.484698E+09 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.219059E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.536443E+10 | 0.471048E+09 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.113142E+10 | 0.379567E+09 | 0.516936E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.103681E+10 | 0.111521E+09 | 0.241080E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.121889E+10 | 0.264515E+09 | 0.414681E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.112412E+10 | 0.109014E+10 | 28224970.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.116956E+10 | 0.124413E+10 | 2249117.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.118405E+10 | 0.378663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.116291E+10 | 0.692133E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.125089E+10 | 0.759183E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.114318E+10 | 0.416168E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.113738E+10 | 0.398565E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.107831E+10 | 0.335985E+09 | 60023324.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.112712E+10 | 0.449810E+09 | 0.258248E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.137646E+11 | 0.303228E+11 | 0.152144E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.103681E+10 | 0.111521E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.125089E+10 | 0.759183E+10 | 0.516936E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.239391E+10 | 0.00 | 0.316753E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.219059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.257182E+10 | 0.00 | 9037847.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.238358E+10 | 0.245068E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.247631E+10 | 0.275316E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.249605E+10 | 0.260334E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.253734E+10 | 0.927186E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.264326E+10 | 0.993379E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.238964E+10 | 0.278008E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.240854E+10 | 0.343386E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.228583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.238107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.291579E+11 | 0.285433E+11 | 0.325791E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.219059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.264326E+10 | 0.993379E+10 | 0.316753E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.113142E+10 | 0.00 | 0.00 | 0.00 | 92215090.18 | 0.00 | 0.751842E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.103681E+10 | 0.00 | 0.00 | 0.00 | 27082805.84 | 0.00 | 0.358425E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.121889E+10 | 0.00 | 0.00 | 0.00 | 63606546.31 | 0.00 | 0.611240E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.112412E+10 | 0.00 | 0.00 | 0.00 | 0.260187E+09 | 0.00 | 41962311.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.116956E+10 | 0.00 | 0.00 | 0.00 | 0.296702E+09 | 0.00 | 3486989.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.118405E+10 | 0.00 | 0.00 | 0.00 | 0.877450E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.116291E+10 | 0.00 | 0.00 | 0.00 | 0.158034E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.125089E+10 | 0.00 | 0.00 | 0.00 | 0.172928E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.114318E+10 | 0.00 | 0.00 | 0.00 | 0.987559E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.113738E+10 | 0.00 | 0.00 | 0.00 | 0.958630E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.107831E+10 | 0.00 | 0.00 | 0.00 | 81465368.50 | 0.00 | 91013946.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.112712E+10 | 0.00 | 0.00 | 0.00 | 0.109330E+09 | 0.00 | 0.383338E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.137646E+11 | 0.00 | 0.00 | 0.00 | 0.706385E+10 | 0.00 | 0.224131E+10 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.103681E+10 | 0.00 | 0.00 | 0.00 | 27082805.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.125089E+10 | 0.00 | 0.00 | 0.00 | 0.172928E+10 | 0.00 | 0.751842E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.239391E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.471048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.219059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.257182E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13650014.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.238358E+10 | 0.00 | 0.00 | 0.00 | 70693162.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.247631E+10 | 0.00 | 0.00 | 0.00 | 79005322.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.249605E+10 | 0.00 | 0.00 | 0.00 | 0.725222E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.253734E+10 | 0.00 | 0.00 | 0.00 | 0.253169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.264326E+10 | 0.00 | 0.00 | 0.00 | 0.272117E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.238964E+10 | 0.00 | 0.00 | 0.00 | 0.839963E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.240854E+10 | 0.00 | 0.00 | 0.00 | 0.105184E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.228583E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.238107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.291579E+11 | 0.00 | 0.00 | 0.00 | 0.801959E+10 | 0.00 | 0.484698E+09 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.219059E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.264326E+10 | 0.00 | 0.00 | 0.00 | 0.272117E+10 | 0.00 | 0.471048E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.368976E+09 | 12622431.75 | 0.00 | 1283554.71 | 0.00 | 69558235.58 | 0.104965E+10 | 0.00 | 0.30 |
February | 0.427735E+09 | 6941069.88 | 0.00 | 1126306.29 | 0.00 | 17145928.14 | 0.109211E+10 | 0.00 | 0.29 |
March | 0.504162E+09 | 1064984.42 | 0.00 | 1454194.41 | 0.00 | 42233441.29 | 0.126189E+10 | 0.00 | 0.31 |
April | 98463996.40 | 13433470.89 | 0.00 | 3924780.50 | 0.00 | 0.00 | 0.246372E+10 | 0.00 | 0.63 |
May | 43691926.41 | 12626301.18 | 0.00 | 5020858.11 | 0.00 | 0.00 | 0.298838E+10 | 0.00 | 0.71 |
June | 15001258.32 | 0.208097E+09 | 0.00 | 7062725.18 | 0.00 | 0.00 | 0.216205E+10 | 0.00 | 0.87 |
July | 6984648.88 | 0.719499E+09 | 0.00 | 9436110.73 | 0.00 | 0.00 | 0.104310E+10 | 0.00 | 0.73 |
August | 14348910.34 | 0.950997E+09 | 0.00 | 7621215.65 | 0.00 | 0.00 | 0.981753E+09 | 0.00 | 0.78 |
September | 31823173.78 | 0.239030E+09 | 0.00 | 6690509.34 | 0.00 | 0.00 | 0.191220E+10 | 0.00 | 0.80 |
October | 29769135.58 | 0.369154E+09 | 0.00 | 5506999.85 | 0.00 | 0.00 | 0.165763E+10 | 0.00 | 0.65 |
November | 0.193824E+09 | 5362388.29 | 0.00 | 2451318.83 | 0.00 | 0.00 | 0.198717E+10 | 0.00 | 0.45 |
December | 0.337990E+09 | 6390315.99 | 0.00 | 1703201.32 | 0.00 | 10849490.16 | 0.127008E+10 | 0.00 | 0.38 |
Annual Sum or Average | 0.207277E+10 | 0.254522E+10 | 0.00 | 53281774.91 | 0.00 | 0.139787E+09 | 0.198697E+11 | 0.00 | 0.58 |
Minimum of Months | 6984648.88 | 1064984.42 | 0.00 | 1126306.29 | 0.00 | 0.00 | 0.981753E+09 | 0.00 | 0.29 |
Maximum of Months | 0.504162E+09 | 0.950997E+09 | 0.00 | 9436110.73 | 0.00 | 69558235.58 | 0.298838E+10 | 0.00 | 0.87 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.220571E+10 | 0.00 | 0.00 | 0.00 | 41340712.75 | 0.00 | 0.00 | 0.00 | 0.18 |
February | 0.242343E+10 | 0.00 | 0.00 | 0.00 | 8985254.57 | 0.00 | 0.00 | 0.00 | 0.18 |
March | 0.313888E+10 | 0.00 | 0.00 | 17855.27 | 785107.62 | 0.00 | 20272213.24 | 0.00 | 0.19 |
April | 0.243189E+10 | 1687269.18 | 0.00 | 1701190.34 | 3152803.81 | 0.00 | 0.126132E+10 | 0.00 | 0.25 |
May | 0.241433E+10 | 3626066.79 | 0.00 | 2227336.39 | 0.00 | 0.00 | 0.172833E+10 | 0.00 | 0.26 |
June | 0.125746E+10 | 11043232.16 | 0.00 | 8209566.93 | 0.00 | 0.00 | 0.371214E+10 | 0.00 | 0.45 |
July | 0.196519E+09 | 0.568045E+09 | 0.00 | 16705958.82 | 0.00 | 0.00 | 0.433760E+10 | 0.00 | 0.61 |
August | 0.343434E+09 | 0.642691E+09 | 0.00 | 14605726.73 | 0.00 | 0.00 | 0.349293E+10 | 0.00 | 0.62 |
September | 0.949924E+09 | 0.214715E+09 | 0.00 | 6474628.68 | 22789.09 | 0.00 | 0.406215E+10 | 0.00 | 0.42 |
October | 0.121154E+10 | 0.478437E+09 | 0.00 | 2829425.86 | 7055452.10 | 0.00 | 0.177513E+10 | 0.00 | 0.32 |
November | 0.255071E+10 | 0.00 | 0.00 | 0.00 | 5204308.26 | 0.00 | 0.00 | 0.00 | 0.18 |
December | 0.215604E+10 | 0.00 | 0.00 | 0.00 | 31228338.58 | 0.00 | 0.00 | 0.00 | 0.18 |
Annual Sum or Average | 0.212799E+11 | 0.192024E+10 | 0.00 | 52771689.02 | 97774766.78 | 0.00 | 0.203899E+11 | 0.00 | 0.32 |
Minimum of Months | 0.196519E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.18 |
Maximum of Months | 0.313888E+10 | 0.642691E+09 | 0.00 | 16705958.82 | 41340712.75 | 0.00 | 0.433760E+10 | 0.00 | 0.62 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:35
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |