Program Version:EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11
Tabular Output Report in Format: HTML
Building: Warehouse
Environment: RUNPERIOD 1 ** New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860
Simulation Timestamp: 2020-06-03 19:11:33
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1719.63 | 355.65 | 355.65 |
Net Site Energy | 1719.63 | 355.65 | 355.65 |
Total Source Energy | 3660.48 | 757.06 | 757.06 |
Net Source Energy | 3660.48 | 757.06 | 757.06 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 0.300 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil #1 | 1.050 |
Fuel Oil #2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4835.13 |
Net Conditioned Building Area | 4835.13 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 0.00 | 857.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 37.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 476.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 123.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 60.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 25.50 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 862.41 | 857.22 | 0.00 | 0.00 | 0.00 | 51.61 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Additional Fuel [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 0.00 | 857.22 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 37.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 476.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 123.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 139.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2.54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 58.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 25.50 | 0.00 | 0.00 | 0.00 | 0.00 | 51.61 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 123.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 25.57 | 177.29 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 178.36 | 177.29 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Additional Fuel Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 123.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 25.57 | 177.29 | 0.00 | 0.00 | 0.00 | 0.01 |
Other | 28.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 178.36 | 177.29 | 0.00 | 0.00 | 0.00 | 0.01 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 862.411 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 862.411 | 100.00 |
Total On-Site and Utility Electric Sources | 862.411 | 100.00 |
Total Electricity End Uses | 862.411 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 51.61 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 51.61 | 100.00 |
Total Water End Uses | 51.61 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 52.33 |
Time Setpoint Not Met During Occupied Cooling | 17.83 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 1794.83 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Meter |NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2006
| Meter |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Meter |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
| Meter |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Meter |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 4A
| Meter |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_NEWYORK
| Meter |ZoneCoolingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneHeatingSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ZoneElectricSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |PeakSpaceGainsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |SpaceGainComponentsAtCoolingPeakMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |ComfortReportSimple55Monthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |OccupantComfortDataSummaryMonthly
| OFFICE PEOPLE |DXReportMonthly
| PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |WindowReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowEnergyReportMonthly
| OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 |WindowZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |WindowEnergyZoneSummaryMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| ELECTRIC TANK |DaylightingReportMonthly
| Environment |CoilReportMonthly
| PSZ-OFFICE HEATING COIL | PSZ-FINE STORAGE HEATING COIL | ZONE3UNITHEATERHEATINGCOIL | PSZ-OFFICE COOLING COIL | PSZ-FINE STORAGE COOLING COIL |FanReportMonthly
| ZONE3UNITHEATERFAN | PSZ-OFFICE_ADDAQ SUPPLY FAN | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN |ZoneTemperatureOscillationReportMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |AirLoopSystemEnergyAndWaterUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentLoadsMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |AirLoopSystemComponentEnergyUseMonthly
| PSZ-OFFICE | PSZ-FINE STORAGE |MechanicalVentilationLoadsMonthly
| ZONE1 OFFICE | ZONE2 FINE STORAGE | ZONE3 BULK STORAGE |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
GeneralValue | |
Program Version and Build | EnergyPlus, Version 9.1.0-Unknown, YMD=2020.06.03 19:11 |
RunPeriod | RUNPERIOD 1 |
Weather File | New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860 |
Latitude [deg] | 40.65 |
Longitude [deg] | -73.8 |
Elevation [m] | 5.00 |
Time Zone | -5.0 |
North Axis Angle [deg] | 90.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Above Ground Wall Area [m2] | 2496.99 | 858.34 | 390.15 | 858.34 | 390.15 |
Window Opening Area [m2] | 17.66 | 6.51 | 0.00 | 0.00 | 11.15 |
Gross Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Above Ground Window-Wall Ratio [%] | 0.71 | 0.76 | 0.00 | 0.00 | 2.86 |
Total | |
Gross Roof Area [m2] | 4598.25 |
Skylight Area [m2] | 14.86 |
Skylight-Roof Ratio [%] | 0.32 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
ZONE1 OFFICE | 236.88 | Yes | Yes | 1010.76 | 1.00 | 149.56 | 0.00 | 17.66 | 17.66 | 10.6337 | 47.38 | 8.0737 |
ZONE2 FINE STORAGE | 1393.41 | Yes | Yes | 2953.02 | 1.00 | 760.80 | 0.00 | 0.00 | 0.00 | 8.5069 | 0.0000 | |
ZONE3 BULK STORAGE | 3204.84 | Yes | Yes | 35277.63 | 1.00 | 1586.63 | 0.00 | 0.00 | 0.00 | 8.5069 | 2.5587 | |
Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.6111 | 967.03 | 2.0915 | |||
Conditioned Total | 4835.13 | 39241.41 | 2496.99 | 0.00 | 17.66 | 17.66 | 8.6111 | 967.03 | 2.0915 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
End UsesElectricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 04-AUG-14:09 | 06-FEB-00:00 | - | - | - | 02-JAN-12:09 |
Heating | 0.00 | 354750.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 18875.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 6329.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 1729.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 72235.72 | 354750.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Propane [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 0.00 | 354750.05 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 18875.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Ventilation (simple) | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
General | 4024.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Pumps | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Water Heater | 1729.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Additional Fuel [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 0.00 | 929.23 | 0.00 | 0.00 | 0.00 |
Cooling | 118.93 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 1507.90 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 390.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 441.11 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 191.88 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 80.76 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 2731.25 | 929.23 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 192.18 | 0.00 | 0.00 | 0.00 |
Cooling | 24.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 311.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 80.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 39.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 16.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 564.88 | 192.18 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Additional Fuel [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 0.00 | 192.18 | 0.00 | 0.00 | 0.00 |
Cooling | 24.60 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 311.86 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 80.80 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 91.23 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 39.68 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 16.70 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 564.88 | 192.18 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
AirTerminal:SingleDuct:UncontrolledDesign Size Maximum Air Flow Rate [m3/s] | |
ZONE1 OFFICE DIRECT AIR | 1.06 |
ZONE2 FINE STORAGE DIRECT AIR | 2.58 |
Design Size Maximum Supply Air Flow Rate [m3/s] | |
ZONE3UNITHEATER | 4.86 |
Design Size Maximum Flow Rate [m3/s] | |
ZONE3UNITHEATERFAN | 4.86 |
Design Size Nominal Capacity [W] | |
ZONE3UNITHEATERHEATINGCOIL | 201880.03 |
PSZ-OFFICE HEATING COIL | 28863.95 |
PSZ-FINE STORAGE HEATING COIL | 87392.23 |
User-Specified Heating Design Capacity [W] | |
ZONE3HIRADIANT | 201880.01 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PSZ-OFFICE | 1.06 | 1.06 | 1.06 | 1.06 | 1.06 | 1.06 | 1.00 | 1.00 | 1.06 |
PSZ-FINE STORAGE | 2.58 | 2.58 | 2.58 | 2.58 | 2.58 | 2.58 | 1.00 | 1.00 | 2.58 |
Maximum Outdoor Air Flow Rate [m3/s] | Minimum Outdoor Air Flow Rate [m3/s] | |
PSZ-OFFICE OA CONTROLLER | 1.06 | 0.120335 |
PSZ-FINE STORAGE OA CONTROLLER | 2.58 | 0.353927 |
Design Size Supply Air Flow Rate [m3/s] | Design Size Heating Supply Air Flow Rate [m3/s] | Design Size Cooling Supply Air Flow Rate [m3/s] | Design Size No Load Supply Air Flow Rate [m3/s] | User-Specified Nominal Cooling Capacity [W] | Design Size Nominal Heating Capacity [W] | Design Size Maximum Supply Air Temperature [C] | Fraction of Supply Air Flow That Goes Through the Controlling Zone | |
PSZ-OFFICE_UNITARY_PACKAGE_DX | 1.06 | 1.06 | 1.06 | 1.06 | 20549.78 | 28863.95 | 40.00 | 1.00 |
PSZ-FINE_UNITARY_PACKAGE_DX | 2.58 | 2.58 | 2.58 | 2.58 | 61276.46 | 87392.23 | 40.00 | 1.00 |
User-Specified Speed 2 Rated Air Flow Rate [m3/s] | Design Size Speed 1 Rated Air Flow Rate [m3/s] | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | Speed 2 Design Size Rated Total Cooling Capacity [W] | Speed 2 User-Specified Rated Total Cooling Capacity [W] | Speed 1 Design Size Rated Total Cooling Capacity [W] | Speed 1 User-Specified Rated Total Cooling Capacity [W] | Speed 2 Design Size Rated Sensible Heat Ratio | Speed 2 User-Specified Rated Sensible Heat Ratio | Speed 1 Design Size Rated Sensible Heat Ratio | Speed 1 User-Specified Rated Sensible Heat Ratio | |
PSZ-OFFICE COOLING COIL | 1.06 | 0.528835 | 1.06 | 20060.70 | 20549.78 | 10274.89 | 20549.78 | 0.744238 | 0.744240 | 0.744240 | 0.744240 |
PSZ-FINE STORAGE COOLING COIL | 2.58 | 1.29 | 2.58 | 58699.63 | 61276.46 | 30638.23 | 61276.46 | 0.686761 | 0.686760 | 0.686760 | 0.686760 |
Design Size Design Maximum Air Flow Rate [m3/s] | Design Electric Power Consumption [W] | |
PSZ-OFFICE_ADDAQ SUPPLY FAN | 1.06 | 1205.86 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | 2.58 | 2818.47 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
OFFICE FRONT WALL | OFFICE FRONT WALL WINDOW 1 | OFFICE FRONT WALL WINDOW2 | OFFICE FRONT DOOR | |
OFFICE LEFT WALL | OFFICE LEFT WALL WINDOW1 | OFFICE LEFT WALL WINDOW2 | OFFICE LEFT WALL DOOR | |
FINE STORAGE FRONT WALL | FINE STORAGE OVERHEAD DOOR1 | |
FINE STORAGE RIGHT WALL | FINE STORAGE OVERHEAD DOOR2 | FINE STORAGE OVERHEAD DOOR3 | FINE STORAGE RIGHT DOOR | |
FINE STORAGE LEFT WALL | FINE STORAGE OVERHEAD DOOR4 | FINE STORAGE LEFT DOOR | |
BULK STORAGE RIGHT WALL | BULK STORAGE OVERHEAD DOOR8 | BULK STORAGE OVERHEAD DOOR9 | BULK STORAGE OVERHEAD DOOR10 | BULK STORAGE OVERHEAD DOOR11 | BULK STORAGE DOOR1 | BULK STORAGE DOOR2 | BULK STORAGE DOOR3 | |
BULK STORAGE REAR WALL | BULK STORAGE OVERHEAD DOOR12 | BULK STORAGE OVERHEAD DOOR13 | BULK STORAGE OVERHEAD DOOR14 | BULK STORAGE OVERHEAD DOOR15 | BULK STORAGE DOOR4 | |
BULK STORAGE LEFT WALL | BULK STORAGE OVERHEAD DOOR1 | BULK STORAGE OVERHEAD DOOR2 | BULK STORAGE OVERHEAD DOOR3 | BULK STORAGE OVERHEAD DOOR4 | BULK STORAGE OVERHEAD DOOR5 | BULK STORAGE OVERHEAD DOOR6 | BULK STORAGE OVERHEAD DOOR7 | BULK STORAGE DOOR5 | |
BULK STORAGE ROOF | SKYLIGHT_R1C1 | SKYLIGHT_R1C2 | SKYLIGHT_R1C3 | SKYLIGHT_R1C4 | SKYLIGHT_R1C5 | SKYLIGHT_R2C1 | SKYLIGHT_R2C2 | SKYLIGHT_R2C3 | SKYLIGHT_R2C4 | SKYLIGHT_R2C5 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
VersionVersion ID | |
1 | 9.0 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 14.00 | 7.30 | 3.30 | 1.20 | -0.20 | 5.60 | 10.90 | 16.10 | 21.70 | 25.00 | 24.80 | 19.90 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860 | 40.65 | -73.80 | -5.00 | 5.00 | 101265 | 1.2036 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 12.47 | 25.20 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | Warehouse | 90.000 | Urban | 4.00000E-002 | 0.40000 | FullExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.220 | 370.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 3 | 66 | 42 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | ZONE1 OFFICE | 0.0 | 0.00 | 0.00 | 0.00 | 4.57 | -12.95 | 2.13 | 1 | 1 | 1 | 0.00 | 9.14 | -25.91 | 5.60E-016 | 0.00 | 4.27 | 4.27 | 1010.76 | TARP | TARP | 236.88 | 149.56 | 128.00 | 17.66 | 6 | 6 | 0 | Yes |
2 | ZONE2 FINE STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 14.29 | -22.82 | 4.51 | 1 | 1 | 1 | 0.00 | 30.48 | -45.72 | 1.87E-015 | 0.00 | 8.53 | 7.81 | 2953.02 | TARP | TARP | 1393.41 | 760.80 | 727.17 | 0.00 | 11 | 6 | 0 | Yes |
3 | ZONE3 BULK STORAGE | 0.0 | 0.00 | 0.00 | 0.00 | 65.53 | -22.86 | 4.27 | 1 | 1 | 1 | 30.48 | 100.58 | -45.72 | 6.16E-015 | 0.00 | 8.53 | 8.53 | 35277.63 | TARP | TARP | 3204.84 | 1586.63 | 1471.35 | 14.86 | 6 | 30 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | ZONE1 OFFICE | 236.88 | 5.0 | 47.376 | 2.111E-002 | 10.634 | 8.074 | 0.000 | 0.000 | 0.000 | 0.000 | 18.707 | No |
2 | ZONE2 FINE STORAGE | 1393.41 | 0.0 | N/A | 0.000 | 8.507 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 8.507 | No |
3 | ZONE3 BULK STORAGE | 3204.84 | 0.0 | N/A | 0.000 | 8.507 | 2.559 | 0.000 | 0.000 | 0.000 | 0.000 | 11.066 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
1 | OFFICE PEOPLE | BLDG_OCC_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 5.0 | 2.111E-002 | 47.376 | 0.300 | 0.700 | AutoCalculate | OFFICE ACTIVITY SCHEDULE | No | 3.8200E-008 | 0 | 5 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | OFFICE LIGHTS | BLDG_LIGHT_OFFICE_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 2518.900 | 10.634 | 503.780 | 0.000 | 0.370 | 0.180 | 0.450 | 1.000 | LightsWired | 0.000 | 2518.900 |
2 | FINE STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 11853.648 | 8.507 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 11853.648 |
3 | BULK STORAGE AREA LIGHTS | BLDG_LIGHT_STORAGE_SCH | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 27263.390 | 8.507 | N/A | 0.000 | 0.420 | 0.180 | 0.400 | 1.000 | LightsWired | 0.000 | 27263.390 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | OFFICE PLUG LOAD | OFFICE_PLUG_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 1912.500 | 8.074 | 382.500 | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 1912.500 |
2 | BULK STORAGE PLUG LOAD | BULK STORAGE PLUG SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 8200.120 | 2.559 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | MiscPlug | 0.000 | 8200.120 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | NONRES_ROOF | 16 | 2 | 2 | 0.167 | 0.3888 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
2 | SEMIHEATED_ROOF | 18 | 2 | 2 | 0.167 | 0.3888 | 0.900 | 0.900 | 0.770 | 0.700 | Smooth |
3 | NONRES_EXT_WALL | 19 | 3 | 4 | 0.167 | 0.6999 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
4 | SEMIHEATED_EXT_WALL | 21 | 3 | 4 | 0.167 | 0.6999 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | SWINGING DOOR_CON | 32 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | SWINGING DOOR_SEMI | 33 | 1 | 1 | 0.167 | 3.975 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
7 | OVERHEAD DOOR_SEMI | 35 | 1 | 1 | 0.167 | 8.233 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
8 | OVERHEAD DOOR_CON | 36 | 1 | 1 | 0.167 | 8.233 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
9 | BULK STORAGE PRODUCTS | 37 | 1 | 18 | 0.500 | 0.5914 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
10 | INTERIOR WALL | 38 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | INSULATEDCEILING | 39 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
12 | OFFICEFLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.1926 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | FINESTORAGEFLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.7922E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | BULKSTORAGEFLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.7415E-01 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | iz-INTERIOR WALL | 43 | 5 | 5 | 2.167 | 0.7747 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
16 | iz-SEMIHEATED_EXT_WALL | 44 | 3 | 4 | 0.167 | 0.6999 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
17 | iz-INSULATEDCEILING | 45 | 2 | 3 | 0.333 | 10.06 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
2 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.572 |
3 | F08 METAL ROOF SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
4 | SEMIHEATED_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 2.572 |
5 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
6 | NONRES_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.329 |
7 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
8 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
9 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.329 |
10 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
11 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
12 | OPAQUE DOOR PANEL_SEMI | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2516 |
13 | OVERHEAD DOOR_SEMI PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.1215 |
14 | OVERHEAD DOOR_CON PANEL | 0.0000 | 0.000 | 0.000 | 0.000 | 0.1215 |
15 | BULK STORAGE PRODUCTS MATERIAL | 2.4384 | 1.442 | 200.231 | 836.800 | 1.691 |
16 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
17 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
18 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
19 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 5.116 |
24 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
25 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 12.55 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 13.41 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
30 | STEEL FRAME/CAVITY | 0.0889 | 0.084 | 641.379 | 502.080 | 1.057 |
31 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
32 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
33 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
34 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
35 | SEMIHEATED_EXTERIOR_WALL_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 1.329 |
36 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
37 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
38 | INTERIOR WALL ADDI INSUL | 0.0000 | 0.043 | 22.426 | 836.800 | 0.5871E-06 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 2 | 0.20482715E-10 | 0.21205973E-14 | 0.31184805E-15 | 0.0000000 |
2 | 1 | -5.2160080 | 0.41303701E-04 | -0.41204219E-04 | 0.97833724E-11 |
3 | 0 | 5.6048073 | 0.38875791 | 0.38884042 | |
4 | 2 | 0.20482715E-10 | 0.21205973E-14 | 0.31184805E-15 | 0.0000000 |
5 | 1 | -5.2160080 | 0.41303701E-04 | -0.41204219E-04 | 0.97833724E-11 |
6 | 0 | 5.6048073 | 0.38875791 | 0.38884042 | |
7 | 4 | 0.73826229E-12 | -0.15793949E-15 | 0.14714251E-14 | 0.12610148E-15 |
8 | 3 | -0.37015163E-03 | 0.48261894E-06 | -0.53553847E-04 | 0.14168247E-12 |
9 | 2 | 1.7048811 | 0.10720623E-01 | 1.1141045 | -0.70963114E-04 |
10 | 1 | -7.1749370 | 0.28051356 | -16.929564 | 0.32672988 |
11 | 0 | 5.9416824 | 0.18002168 | 16.286769 | |
12 | 4 | 0.73826229E-12 | -0.15793949E-15 | 0.14714251E-14 | 0.12610148E-15 |
13 | 3 | -0.37015163E-03 | 0.48261894E-06 | -0.53553847E-04 | 0.14168247E-12 |
14 | 2 | 1.7048811 | 0.10720623E-01 | 1.1141045 | -0.70963114E-04 |
15 | 1 | -7.1749370 | 0.28051356 | -16.929564 | 0.32672988 |
16 | 0 | 5.9416824 | 0.18002168 | 16.286769 | |
17 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
18 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
19 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
20 | 0 | 3.9747885 | 3.9747885 | 3.9747885 | |
21 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
22 | 0 | 8.2334905 | 8.2334905 | 8.2334905 | |
23 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
24 | 0 | 8.2334905 | 8.2334905 | 8.2334905 | |
25 | 18 | 0.12003549E-12 | -0.36149852E-21 | 0.11999160E-12 | -0.69171859E-14 |
26 | 17 | -0.26702818E-10 | 0.22043783E-17 | -0.26702965E-10 | 0.15647703E-11 |
27 | 16 | 0.26199194E-08 | 0.46087291E-16 | 0.26199192E-08 | -0.15597178E-09 |
28 | 15 | -0.14918350E-06 | -0.27301975E-15 | -0.14918350E-06 | 0.90448703E-08 |
29 | 14 | 0.54929883E-05 | 0.10218664E-13 | 0.54929883E-05 | -0.34010628E-06 |
30 | 13 | -0.13812653E-03 | 0.13886261E-11 | -0.13812653E-03 | 0.87613853E-05 |
31 | 12 | 0.24466257E-02 | 0.76740851E-10 | 0.24466257E-02 | -0.15954016E-03 |
32 | 11 | -0.31099262E-01 | 0.20215154E-08 | -0.31099262E-01 | 0.20926433E-02 |
33 | 10 | 0.28694928 | 0.26940884E-07 | 0.28694928 | -0.20002833E-01 |
34 | 9 | -1.9353699 | 0.18750649E-06 | -1.9353699 | 0.14030665 |
35 | 8 | 9.5767226 | 0.68900696E-06 | 9.5767226 | -0.72468789 |
36 | 7 | -34.784653 | 0.13258951E-05 | -34.784653 | 2.7565275 |
37 | 6 | 92.438040 | 0.12976568E-05 | 92.438040 | -7.6923258 |
38 | 5 | -178.18614 | 0.60985027E-06 | -178.18614 | 15.604270 |
39 | 4 | 245.02895 | 0.12430126E-06 | 245.02895 | -22.615757 |
40 | 3 | -233.27712 | 0.91617964E-08 | -233.27712 | 22.714127 |
41 | 2 | 145.61910 | 0.16319500E-09 | 145.61910 | -14.964058 |
42 | 1 | -53.478849 | 0.26256209E-11 | -53.478849 | 5.7996512 |
43 | 0 | 8.7411694 | -0.39181092E-12 | 8.7411694 | |
44 | 5 | -0.68112304E-12 | 0.61645773E-13 | -0.20199983E-12 | 0.95058421E-15 |
45 | 4 | 0.71499529E-06 | 0.73238302E-07 | 0.28552134E-06 | -0.33479849E-12 |
46 | 3 | -0.58529659E-02 | 0.62218017E-03 | -0.21917430E-02 | 0.29169470E-06 |
47 | 2 | 1.2914758 | 0.88958368E-01 | 0.40042664 | -0.15953103E-02 |
48 | 1 | -8.6129398 | 0.38073474 | -3.1694576 | 0.22491773 |
49 | 0 | 7.9317533 | 0.13060792 | 3.3724149 | |
50 | 3 | -0.49407978E-15 | 0.44230608E-16 | -0.53860842E-16 | 0.0000000 |
51 | 2 | 0.54884850E-03 | 0.14309697E-03 | 0.26444340E-03 | -0.39739853E-15 |
52 | 1 | -3.9407614 | 2.0053241 | -3.6132068 | 0.31450573E-03 |
53 | 0 | 13.994357 | 8.0573072 | 13.672611 | |
54 | 7 | -0.21936956E-08 | -0.76657665E-15 | 0.52174295E-14 | -0.76362207E-16 |
55 | 6 | 0.54250385E-05 | 0.36865710E-08 | 0.31904099E-02 | -0.26763832E-04 |
56 | 5 | -0.38781740E-03 | 0.21819055E-05 | -0.22375527 | 0.19564212E-02 |
57 | 4 | 0.89061350E-02 | 0.99303795E-04 | 4.8300570 | -0.45269896E-01 |
58 | 3 | -0.78164548E-01 | 0.78949647E-03 | -38.024306 | 0.39868569 |
59 | 2 | 0.27748674 | 0.13132576E-02 | 116.48957 | -1.4180145 |
60 | 1 | -0.40047331 | 0.39992572E-03 | -143.91062 | 2.0490943 |
61 | 0 | 0.19524127 | 0.97244710E-05 | 60.838472 | |
62 | 7 | -0.53942680E-08 | -0.11156834E-13 | 0.16318657E-14 | -0.36257882E-16 |
63 | 6 | 0.25438785E-05 | 0.15223906E-08 | 0.31992327E-02 | -0.26837845E-04 |
64 | 5 | -0.16605865E-03 | 0.89659996E-06 | -0.22425660 | 0.19608463E-02 |
65 | 4 | 0.37075836E-02 | 0.40698259E-04 | 4.8384045 | -0.45350141E-01 |
66 | 3 | -0.32199378E-01 | 0.32283529E-03 | -38.071448 | 0.39920679 |
67 | 2 | 0.11382527 | 0.53586778E-03 | 116.58131 | -1.4192416 |
68 | 1 | -0.16395953 | 0.16275009E-03 | -143.96461 | 2.0499819 |
69 | 0 | 0.79856572E-01 | 0.39490086E-05 | 60.838472 | |
70 | 7 | -0.57660871E-08 | -0.13610624E-13 | 0.89936022E-15 | -0.28491615E-16 |
71 | 6 | 0.24333103E-05 | 0.14269892E-08 | 0.31996257E-02 | -0.26841142E-04 |
72 | 5 | -0.15663594E-03 | 0.83977476E-06 | -0.22427892 | 0.19610433E-02 |
73 | 4 | 0.34808858E-02 | 0.38103208E-04 | 4.8387759 | -0.45353710E-01 |
74 | 3 | -0.30176241E-01 | 0.30214868E-03 | -38.073544 | 0.39922996 |
75 | 2 | 0.10659492 | 0.50136596E-03 | 116.58539 | -1.4192962 |
76 | 1 | -0.15349297 | 0.15221123E-03 | -143.96701 | 2.0500213 |
77 | 0 | 0.74745977E-01 | 0.36906361E-05 | 60.838472 | |
78 | 5 | -0.20199983E-12 | 0.61645773E-13 | -0.68112304E-12 | 0.95058421E-15 |
79 | 4 | 0.28552134E-06 | 0.73238302E-07 | 0.71499529E-06 | -0.33479849E-12 |
80 | 3 | -0.21917430E-02 | 0.62218017E-03 | -0.58529659E-02 | 0.29169470E-06 |
81 | 2 | 0.40042664 | 0.88958368E-01 | 1.2914758 | -0.15953103E-02 |
82 | 1 | -3.1694576 | 0.38073474 | -8.6129398 | 0.22491773 |
83 | 0 | 3.3724149 | 0.13060792 | 7.9317533 | |
84 | 4 | 0.14714251E-14 | -0.15793949E-15 | 0.73826229E-12 | 0.12610148E-15 |
85 | 3 | -0.53553847E-04 | 0.48261894E-06 | -0.37015163E-03 | 0.14168247E-12 |
86 | 2 | 1.1141045 | 0.10720623E-01 | 1.7048811 | -0.70963114E-04 |
87 | 1 | -16.929564 | 0.28051356 | -7.1749370 | 0.32672988 |
88 | 0 | 16.286769 | 0.18002168 | 5.9416824 | |
89 | 3 | -0.53860842E-16 | 0.44230608E-16 | -0.49407978E-15 | 0.0000000 |
90 | 2 | 0.26444340E-03 | 0.14309697E-03 | 0.54884850E-03 | -0.39739853E-15 |
91 | 1 | -3.6132068 | 2.0053241 | -3.9407614 | 0.31450573E-03 |
92 | 0 | 13.672611 | 8.0573072 | 13.994357 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | NONRESWINDOW_U_0.52_SHGC_0.4 | 28 | 1 | VerySmooth | 2.956 | 0.395 | 0.315 | 0.401 |
2 | SKYLIGHT_U_0.6_SHGC_0.4 | 29 | 1 | VerySmooth | 3.411 | 0.396 | 0.314 | 0.401 |
3 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 30 | 1 | VerySmooth | 3.411 | 0.396 | 0.314 | 0.401 |
4 | SKYLIGHT DOUBLE CLEAR | 34 | 3 | VerySmooth | 3.715 | 0.720 | 0.644 | 0.817 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | NONRES WINDOW GLAZING LAYER | SpectralAverage | 1.66926E-002 | 0.31435 | 0.46310 | 0.46310 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 9.92378E-002 | 1.00000 | No | |
2 | NONRES SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.31383 | 0.45189 | 0.45189 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 1.61274E-002 | 1.00000 | No | |
3 | SEMIHEATED SKYLIGHT GLAZING LAYER | SpectralAverage | 2.00000E-003 | 0.31383 | 0.45189 | 0.45189 | 0.40000 | 0.13759 | 0.17962 | 0.00000 | 0.84000 | 0.84000 | 1.61274E-002 | 1.00000 | No | |
4 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No | |
5 | CLEAR 2.5MM | SpectralAverage | 2.50000E-003 | 0.80000 | 7.50000E-002 | 7.50000E-002 | 0.90100 | 8.10000E-002 | 8.10000E-002 | 0.00000 | 0.84000 | 0.84000 | 0.90000 | 1.00000 | No |
Material Name | GasType | Thickness {m} | |
1 | AIR 3MM | Air | 3.200E-003 |
Calculation Method | Value {days} | Allowable Number Figures in Shadow Overlap {} | Polygon Clipping Algorithm | Sky Diffuse Modeling Algorithm | External Shading Calculation Method | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | AverageOverDaysInFrequency | 20 | 15000 | SutherlandHodgman | SimpleSkyDiffuseModeling | InternalCalculation | No | No | No |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | ELECTRIC TANK | 7.5708E-002 | 6154.7 | 1.055 | 0.5308 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | OFFICE INFILTRATION | OFFICE INFIL SCHEDULE | ZONE1 OFFICE | 236.88 | 5.0 | 6.083E-002 | 2.568E-004 | 3.964E-004 | 0.217 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | OFFICE DOOR INFILTRATION | INFIL_DOOR_OPENING_SCH | ZONE1 OFFICE | 236.88 | 5.0 | 0.289 | 1.219E-003 | 1.882E-003 | 1.029 | 1.000 | 0.000 | 0.000 | 0.000 |
3 | FINE STORAGE INFILTRATION | FINE SORAGE INFIL SCHEDULE | ZONE2 FINE STORAGE | 1393.41 | 0.0 | 0.889 | 6.381E-004 | 4.064E-004 | 1.084 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | BULK STORAGE INFILTRATION | BULK STORAGE INFIL_BASE SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 3.431 | 1.071E-003 | 6.993E-004 | 0.350 | 0.000 | 0.000 | 0.224 | 0.000 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/person Area {m3/s-person} | ACH - Air Changes per Hour | Fan Type {Exhaust;Intake;Natural} | Fan Pressure Rise {Pa} | Fan Efficiency {} | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | Minimum Indoor Temperature{C}/Schedule | Maximum Indoor Temperature{C}/Schedule | Delta Temperature{C}/Schedule | Minimum Outdoor Temperature{C}/Schedule | Maximum Outdoor Temperature{C}/Schedule | Maximum WindSpeed{m/s} | |
1 | BULK STORAGE VENTILATION-1 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 37.760 | 1.178E-002 | N/A | 3.853 | Exhaust | 31.136 | 0.5 | 1.000 | 0.000 | 0.000 | 0.000 | 29.44 | 100.00 | -100.00 | -100.00 | 100.00 | 40.00 |
2 | BULK STORAGE VENTILATION-2 | ALWAYS ON SCHEDULE | ZONE3 BULK STORAGE | 3204.84 | 0.0 | 0.944 | 2.945E-004 | N/A | 9.632E-002 | Natural | 0.000 | 1.0 | 0.000 | 0.000 | 0.224 | 0.000 | -73.33 | 29.44 | -100.00 | -100.00 | 100.00 | 40.00 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | ZONE1 OFFICE | Mixing/Well-Stirred |
2 | ZONE2 FINE STORAGE | Mixing/Well-Stirred |
3 | ZONE3 BULK STORAGE | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Sizing Factor ID | Value | |
1 | Global | 1.2000 |
2 | Zone ZONE1 OFFICE | 1.2000 |
3 | Zone ZONE2 FINE STORAGE | 1.2000 |
4 | Zone ZONE3 BULK STORAGE | 1.2000 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | ZONE1 OFFICE | Cooling | 10708.09408 | 12849.71290 | 0.88139 | 1.05767 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 31.06400 | 1.40969E-002 | 236.87965 | 5.00000 | 0.12034 | 0.00000 |
2 | ZONE1 OFFICE | Heating | 12871.12641 | 15445.35169 | 0.36155 | 0.43386 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | -10.70000 | 1.50390E-003 | 236.87965 | 5.00000 | 0.12034 | 0.00000 |
3 | ZONE2 FINE STORAGE | Cooling | 33441.53399 | 40129.84079 | 2.14592 | 2.57511 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 32.10000 | 1.40969E-002 | 1393.40969 | 0.00000 | 0.35393 | 0.00000 |
4 | ZONE2 FINE STORAGE | Heating | 68575.61087 | 82290.73305 | 1.62176 | 1.94611 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | -10.70000 | 1.50390E-003 | 1393.40969 | 0.00000 | 0.35393 | 0.00000 |
5 | ZONE3 BULK STORAGE | Cooling | 0.00000 | 0.00000 | 0.00000 | 0.81403 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 32.10000 | 1.40969E-002 | 3204.84228 | 0.00000 | 0.81403 | 0.00000 | |
6 | ZONE3 BULK STORAGE | Heating | 168233.34555 | 201880.01466 | 4.05122 | 4.86147 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | -10.70000 | 1.50390E-003 | 3204.84228 | 0.00000 | 0.81403 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PSZ-OFFICE | Cooling | Sensible | 16263.72 | 1.05767 | 1.05767 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
2 | PSZ-OFFICE | Heating | Sensible | 14565.38 | 0.43386 | 0.43386 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 |
3 | PSZ-FINE STORAGE | Cooling | Sensible | 48086.82 | 2.57511 | 2.57511 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 05:00:00 |
4 | PSZ-FINE STORAGE | Heating | Sensible | 68790.20 | 1.94611 | 1.94611 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:Uncontrolled | ZONE1 OFFICE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 1.05767 |
2 | AirTerminal:SingleDuct:Uncontrolled | ZONE2 FINE STORAGE DIRECT AIR | Design Size Maximum Air Flow Rate [m3/s] | 2.57511 |
3 | ZoneHVAC:UnitHeater | ZONE3UNITHEATER | Design Size Maximum Supply Air Flow Rate [m3/s] | 4.86147 |
4 | Fan:ConstantVolume | ZONE3UNITHEATERFAN | Design Size Maximum Flow Rate [m3/s] | 4.86147 |
5 | Coil:Heating:Fuel | ZONE3UNITHEATERHEATINGCOIL | Design Size Nominal Capacity [W] | 201880.03416 |
6 | ZoneHVAC:HighTemperatureRadiant | ZONE3HIRADIANT | User-Specified Heating Design Capacity [W] | 201880.01466 |
7 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 1.05767 |
8 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.05767 |
9 | AirLoopHVAC | PSZ-OFFICE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 1.05767 |
10 | AirLoopHVAC | PSZ-OFFICE | Adjusted Heating Design Air Flow Rate [m3/s] | 1.05767 |
11 | AirLoopHVAC | PSZ-OFFICE | Adjusted Cooling Design Air Flow Rate [m3/s] | 1.05767 |
12 | AirLoopHVAC | PSZ-OFFICE | Adjusted Main Design Air Flow Rate [m3/s] | 1.05767 |
13 | AirLoopHVAC | PSZ-OFFICE | User Heating Air Flow Ratio [] | 1.00000 |
14 | AirLoopHVAC | PSZ-OFFICE | Calculated Heating Air Flow Ratio [] | 1.00000 |
15 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.57511 |
16 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 2.57511 |
17 | AirLoopHVAC | PSZ-FINE STORAGE | Sum of Air Terminal Maximum Flow Rates [m3/s] | 2.57511 |
18 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Heating Design Air Flow Rate [m3/s] | 2.57511 |
19 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Cooling Design Air Flow Rate [m3/s] | 2.57511 |
20 | AirLoopHVAC | PSZ-FINE STORAGE | Adjusted Main Design Air Flow Rate [m3/s] | 2.57511 |
21 | AirLoopHVAC | PSZ-FINE STORAGE | User Heating Air Flow Ratio [] | 1.00000 |
22 | AirLoopHVAC | PSZ-FINE STORAGE | Calculated Heating Air Flow Ratio [] | 1.00000 |
23 | AirLoopHVAC | PSZ-OFFICE | Design Supply Air Flow Rate [m3/s] | 1.05767 |
24 | AirLoopHVAC | PSZ-FINE STORAGE | Design Supply Air Flow Rate [m3/s] | 2.57511 |
25 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 1.05767 |
26 | Controller:OutdoorAir | PSZ-OFFICE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.12034 |
27 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 1.05767 |
28 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 1.05767 |
29 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 1.05767 |
30 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 1.05767 |
31 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 1.05767 |
32 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 0.52884 |
33 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 1.05767 |
34 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 20060.70161 |
35 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 20549.78000 |
36 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 10274.89000 |
37 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 20549.78000 |
38 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.74424 |
39 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.74424 |
40 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.74424 |
41 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.74424 |
42 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 20549.78000 |
43 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 28863.95190 |
44 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
45 | AirLoopHVAC:UnitarySystem | PSZ-OFFICE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
46 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 1.05767 |
47 | Fan:SystemModel | PSZ-OFFICE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 1205.85758 |
48 | Coil:Heating:Fuel | PSZ-OFFICE HEATING COIL | Design Size Nominal Capacity [W] | 28863.95190 |
49 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 2.57511 |
50 | Controller:OutdoorAir | PSZ-FINE STORAGE OA CONTROLLER | Minimum Outdoor Air Flow Rate [m3/s] | 0.35393 |
51 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Supply Air Flow Rate [m3/s] | 2.57511 |
52 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Heating Supply Air Flow Rate [m3/s] | 2.57511 |
53 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Cooling Supply Air Flow Rate [m3/s] | 2.57511 |
54 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size No Load Supply Air Flow Rate [m3/s] | 2.57511 |
55 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 2 Rated Air Flow Rate [m3/s] | 2.57511 |
56 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Design Size Speed 1 Rated Air Flow Rate [m3/s] | 1.28756 |
57 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | User-Specified Speed 1 Rated Air Flow Rate [m3/s] | 2.57511 |
58 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Total Cooling Capacity [W] | 58699.62926 |
59 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Total Cooling Capacity [W] | 61276.46000 |
60 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Total Cooling Capacity [W] | 30638.23000 |
61 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Total Cooling Capacity [W] | 61276.46000 |
62 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 Design Size Rated Sensible Heat Ratio | 0.68676 |
63 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 2 User-Specified Rated Sensible Heat Ratio | 0.68676 |
64 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 Design Size Rated Sensible Heat Ratio | 0.68676 |
65 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | Speed 1 User-Specified Rated Sensible Heat Ratio | 0.68676 |
66 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | User-Specified Nominal Cooling Capacity [W] | 61276.46000 |
67 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Nominal Heating Capacity [W] | 87392.23427 |
68 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Design Size Maximum Supply Air Temperature [C] | 40.00000 |
69 | AirLoopHVAC:UnitarySystem | PSZ-FINE_UNITARY_PACKAGE_DX | Fraction of Supply Air Flow That Goes Through the Controlling Zone | 1.00000 |
70 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Size Design Maximum Air Flow Rate [m3/s] | 2.57511 |
71 | Fan:SystemModel | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Design Electric Power Consumption [W] | 2818.46992 |
72 | Coil:Heating:Fuel | PSZ-FINE STORAGE HEATING COIL | Design Size Nominal Capacity [W] | 87392.23427 |
Component Type | Component Name | Standard Rating (Net) Cooling Capacity {W} | Standard Rated Net COP {W/W} | EER {Btu/W-h} | SEER {Btu/W-h} | IEER {Btu/W-h} | |
1 | Coil:Cooling:DX:MultiSpeed | PSZ-OFFICE COOLING COIL | 19728.6 | 10.33 | |||
2 | Coil:Cooling:DX:MultiSpeed | PSZ-FINE STORAGE COOLING COIL | 59275.3 | 13.40 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1 |
2 | ML KING BIRTHDAY | Holiday | InputFile | 01/16 | 1 |
3 | WASHINGTON'S BIRTHDAY | Holiday | InputFile | 02/20 | 1 |
4 | MEMORIAL DAY | Holiday | InputFile | 05/29 | 1 |
5 | FOURTH OF JULY | Holiday | InputFile | 07/04 | 1 |
6 | LABOR DAY | Holiday | InputFile | 09/04 | 1 |
7 | COLUMBUS DAY | Holiday | InputFile | 10/09 | 1 |
8 | VETERANS DAY | Holiday | InputFile | 11/11 | 1 |
9 | THANKSGIVING DAY | Holiday | InputFile | 11/23 | 1 |
10 | CHRISTMAS DAY | Holiday | InputFile | 12/25 | 1 |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
NumberofWarmupDays | |
1 | 6 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | ZONE1 OFFICE | RunPeriod: RUNPERIOD 1 | 0.3878092280 | 0.3893082333 | Pass | Pass | 0.7256681360 | 0.7477928537 | Pass | Pass |
2 | ZONE2 FINE STORAGE | RunPeriod: RUNPERIOD 1 | 1.2979080096 | 1.1461551200 | Pass | Pass | 0.6267118832 | 0.5741196154 | Pass | Pass |
3 | ZONE3 BULK STORAGE | RunPeriod: RUNPERIOD 1 | 1.1062265145E-004 | 2.0560884741E-004 | Pass | Pass | 2.5475992367E-002 | 2.0240097704E-002 | Pass | Pass |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | -10.70 | 0.00 | -10.70 | Wetbulb [C] | 7.50 | 320.00 |
NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 32.10 | 7.40 | 23.10 | Wetbulb [C] | 5.60 | 230.00 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 110.54 | 97.44 | 270.00 | 90.00 | W |
OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 39.02 | 30.56 | 0.00 | 90.00 | N |
FINE STORAGE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 169.07 | 161.64 | 270.00 | 90.00 | W |
FINE STORAGE RIGHT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 260.10 | 243.29 | 180.00 | 90.00 | S |
FINE STORAGE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 182.07 | 172.69 | 0.00 | 90.00 | N |
FINE STORAGE OFFICE FRONT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 110.54 | 110.54 | 270.00 | 90.00 | W |
FINE STORAGE OFFICE LEFT WALL | NONRES_EXT_WALL | 0.30 | 0.634 | 0.700 | 39.02 | 39.02 | 0.00 | 90.00 | N |
FINE STORAGE ROOF | NONRES_ROOF | 0.23 | 0.369 | 0.389 | 1393.41 | 1393.41 | 90.00 | 0.00 | |
BULK STORAGE RIGHT WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.634 | 0.700 | 598.24 | 568.60 | 180.00 | 90.00 | S |
BULK STORAGE REAR WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.634 | 0.700 | 390.15 | 358.48 | 90.00 | 90.00 | E |
BULK STORAGE LEFT WALL | SEMIHEATED_EXT_WALL | 0.30 | 0.634 | 0.700 | 598.24 | 544.27 | 0.00 | 90.00 | N |
BULK STORAGE ROOF | SEMIHEATED_ROOF | 0.23 | 0.369 | 0.389 | 3204.84 | 3189.98 | 270.00 | 0.00 | |
OFFICE FLOOR | OFFICEFLOOR_FFACTOR | 1.00 | 0.193 | 236.88 | 236.88 | 90.00 | 180.00 | ||
FINE STORAGE FLOOR | FINESTORAGEFLOOR_FFACTOR | 1.00 | 0.079 | 1156.53 | 1156.53 | 90.00 | 180.00 | ||
BULK STORAGE FLOOR | BULKSTORAGEFLOOR_FFACTOR | 1.00 | 0.074 | 3204.84 | 3204.84 | 90.00 | 180.00 |
Construction | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
OFFICE FRONT WALL WINDOW 1 | NONRESWINDOW_U_0.52_SHGC_0.4 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.956 | 0.395 | 0.401 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE FRONT WALL WINDOW2 | NONRESWINDOW_U_0.52_SHGC_0.4 | 5.58 | 0.00 | 0.00 | 5.58 | 5.58 | 2.956 | 0.395 | 0.401 | No | OFFICE FRONT WALL | 270.00 | 90.00 | W | ||
OFFICE LEFT WALL WINDOW1 | NONRESWINDOW_U_0.52_SHGC_0.4 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.956 | 0.395 | 0.401 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
OFFICE LEFT WALL WINDOW2 | NONRESWINDOW_U_0.52_SHGC_0.4 | 3.25 | 0.00 | 0.00 | 3.25 | 3.25 | 2.956 | 0.395 | 0.401 | No | OFFICE LEFT WALL | 0.00 | 90.00 | N | ||
SKYLIGHT_R1C1 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C2 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C3 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C4 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R1C5 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C1 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C2 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C3 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C4 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
SKYLIGHT_R2C5 | SEMIHTDSKYLIGHT_U_0.6_SHGC_0.4 | 1.49 | 0.00 | 0.00 | 1.49 | 1.49 | 3.411 | 0.396 | 0.401 | 0.000 | 0.000 | No | BULK STORAGE ROOF | 0.00 | 0.00 | |
Total or Average | 32.53 | 3.164 | 0.395 | 0.401 | ||||||||||||
North Total or Average | 6.51 | 2.956 | 0.395 | 0.401 | ||||||||||||
Non-North Total or Average | 26.02 | 3.216 | 0.395 | 0.401 |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
OFFICE FRONT DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | OFFICE FRONT WALL |
OFFICE LEFT WALL DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | OFFICE LEFT WALL |
FINE STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE FRONT WALL |
FINE STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE RIGHT WALL |
FINE STORAGE RIGHT DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | FINE STORAGE RIGHT WALL |
FINE STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_CON | 3.688 | 8.233 | 7.43 | FINE STORAGE LEFT WALL |
FINE STORAGE LEFT DOOR | SWINGING DOOR_CON | 2.492 | 3.975 | 1.95 | FINE STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR8 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR9 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR10 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR11 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 5.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR1 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR2 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE DOOR3 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE RIGHT WALL |
BULK STORAGE OVERHEAD DOOR12 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR13 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR14 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR15 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE REAR WALL |
BULK STORAGE DOOR4 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE REAR WALL |
BULK STORAGE OVERHEAD DOOR1 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR2 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR3 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR4 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR5 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR6 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE OVERHEAD DOOR7 | OVERHEAD DOOR_SEMI | 3.688 | 8.233 | 7.43 | BULK STORAGE LEFT WALL |
BULK STORAGE DOOR5 | SWINGING DOOR_SEMI | 2.492 | 3.975 | 1.95 | BULK STORAGE LEFT WALL |
Report: Shading Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
OFFICE FRONT WALL WINDOW 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE FRONT WALL WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
OFFICE LEFT WALL WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
OFFICE LEFT WALL WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
SKYLIGHT_R1C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R1C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C4 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
SKYLIGHT_R2C5 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Interior LightingZone | Lighting Power Density [W/m2] | Zone Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
OFFICE LIGHTS | ZONE1 OFFICE | 10.6337 | 236.88 | 2518.90 | LightsWired | BLDG_LIGHT_OFFICE_SCH | 65.78 | 168.00 | 64.76 | 0.0000 | Y | 30.62 |
FINE STORAGE AREA LIGHTS | ZONE2 FINE STORAGE | 8.5069 | 1393.41 | 11853.65 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 135.00 |
BULK STORAGE AREA LIGHTS | ZONE3 BULK STORAGE | 8.5069 | 3204.84 | 27263.39 | LightsWired | BLDG_LIGHT_STORAGE_SCH | 61.98 | 168.00 | 60.67 | 0.0000 | Y | 310.50 |
Interior Lighting Total | 8.6111 | 4835.13 | 41635.94 | 476.13 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
None |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS | 7857.00 | AstronomicalClock | - | 83.64 | 83.64 | 123.36 | |
Exterior Lighting Total | 7857.00 | 123.36 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Central PlantType | Nominal Capacity [W] | Nominal Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 20549.78 | 15293.97 | 5255.81 | 0.74 | 3.50 | |||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | 61276.46 | 42082.22 | 19194.24 | 0.69 | 3.30 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER [Btu/W-h] | IEER [Btu/W-h] | |
PSZ-OFFICE COOLING COIL | 19728.6 | 10.33 | ||||
PSZ-FINE STORAGE COOLING COIL | 59275.3 | 13.40 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | ||||||||
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
ZONE3UNITHEATERHEATINGCOIL | Coil:Heating:Fuel | 201880.03 | 0.79 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | 28863.95 | 0.80 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | 87392.23 | 0.79 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electric Power [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
ZONE3UNITHEATERFAN | Fan:ConstantVolume | 0.54 | 49.80 | 4.86 | 451.68 | 92.91 | 1.00 | 3.17 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 |
PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.55 | 622.50 | 1.06 | 1205.86 | 1140.11 | 1.00 | 1.35 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 |
PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 0.57 | 622.50 | 2.58 | 2818.47 | 1094.51 | 1.00 | 1.25 | General | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electric Power [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
None |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
ELECTRIC TANK | WaterHeater:Mixed | 0.08 | 6154.75 | 1.00 | 1.06 | 0.53 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 10708.09 | 12849.71 | 54.25 | 0.881 | 1.058 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 23.90 | 23.90 | 0.00840 | 31.06 | 0.01410 | 0.120 | 0.00 |
ZONE2 FINE STORAGE | 33441.53 | 40129.84 | 28.80 | 2.146 | 2.575 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 26.70 | 26.70 | 0.00878 | 32.10 | 0.01410 | 0.354 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.000 | 0.814 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 10.00 | 0.00 | 0.00378 | 32.10 | 0.01410 | 0.814 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
ZONE1 OFFICE | 12871.13 | 15445.35 | 65.20 | 0.362 | 0.434 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 21.10 | 21.10 | 0.00698 | -10.70 | 0.00150 | 0.120 | 0.00 |
ZONE2 FINE STORAGE | 68575.61 | 82290.73 | 59.06 | 1.622 | 1.946 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 15.56 | 15.54 | 0.00518 | -10.70 | 0.00150 | 0.354 | 0.00 |
ZONE3 BULK STORAGE | 168233.35 | 201880.01 | 62.99 | 4.051 | 4.861 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | 10.00 | 9.98 | 0.00763 | -10.70 | 0.00150 | 0.814 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PSZ-OFFICE | 1.06 | 1.06 | 0.43 | 0.43 | 1.0577 | 1.0577 | 1.0577 | 1.0000 | 1.0000 |
PSZ-FINE STORAGE | 2.58 | 2.58 | 1.95 | 1.95 | 2.5751 | 2.5751 | 2.5751 | 1.0000 | 1.0000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | 201880.034 | 201880.034 | -999.0 | -999.0 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | 201880.03 | 201880.03 | 4.861469 | 6.52 | 6.52 | 0.00660329 | 43.33 | 27.10 | 0.01600000 | -10.70 | 0.00150390 | -10.70 | 0.0000 | 9.98 | 0.00762889 | 100.0000 | 201880.01 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-OFFICE | 20549.780 | 0.000 | 1.057670 | -999.0 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 20549.78 | 17325.07 | 1.057670 | 24.71 | 17.08 | 0.00904509 | 12.00 | 11.25 | 0.00800000 | 31.06 | 0.01409688 | 22.82 | 11.3774 | 23.90 | 0.00839654 | 45.4614 | 10708.09 | 0.00 | -999.00 | -999.00 |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-OFFICE | 28863.952 | 28863.952 | -999.0 | -999.0 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 28863.95 | 28863.95 | 1.057668 | 12.24 | 8.61 | 0.00546237 | 40.00 | 21.14 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 11.3774 | 21.10 | 0.00698167 | 44.9212 | 12871.13 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoopHVAC | PSZ-FINE STORAGE | 61276.460 | 0.000 | 2.575110 | -999.0 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 61276.46 | 49987.13 | 2.575110 | 27.44 | 18.38 | 0.00951156 | 12.00 | 11.25 | 0.00800000 | 32.10 | 0.01409687 | 23.10 | 13.7442 | 26.70 | 0.00878093 | 40.2271 | 32088.23 | 0.00 | -999.00 | -999.00 |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PSZ-FINE STORAGE | 87392.234 | 87392.234 | -999.0 | -999.0 | -999.000 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 87392.23 | 87392.23 | 2.575108 | 10.77 | 6.79 | 0.00451109 | 40.00 | 21.14 | 0.00800000 | -10.70 | 0.00150390 | -10.70 | 13.7442 | 15.54 | 0.00517956 | 47.3579 | 68575.61 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [C] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [KGWATER/KGDRYAIR] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [KGWATER/KGDRYAIR] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
ZONE3UNITHEATERHEATINGCOIL | COIL:HEATING:FUEL | Zone Equipment | ZONEHVAC:UNITHEATER | ZONE3UNITHEATER | ZONE3 BULK STORAGE | N/A | N/A | N/A | Yes | No | unknown | No | 201880.034 | 201880.034 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1034.5832 | 1004.8586 | 1.2036 | ZONE3UNITHEATERFAN | Fan:ConstantVolume | 4.861469 | 5.85123970 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 17:00:00 | 201880.03 | 201880.03 | 1.0000 | 5.85123970 | 4.861469 | 6.52 | 6.52 | 0.00660329 | 23147.0 | 43.33 | 27.10 | 0.01600000 | 84847.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 201880.03 | -10.70 | 0.00150390 | -10.70 | 0.00000000 | 0.0000 | 9.98 | 0.00762889 | 9.98 | 0.00762889 | 100.0000 | 201880.01 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 20549.780 | 0.000 | 1.057670 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.6544 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 20549.78 | 17325.07 | 1.0000 | 1.27300630 | 1.057670 | 24.71 | 17.08 | 0.00904509 | 47870.5 | 12.00 | 11.25 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 20549.78 | 31.06 | 0.01409688 | 22.82 | 0.12033533 | 11.3774 | 23.90 | 0.00839654 | 23.90 | 0.00839654 | 45.4614 | 10708.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-OFFICE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-OFFICE | ZONE1 OFFICE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 28863.952 | 28863.952 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-OFFICE_ADDAQ SUPPLY FAN | Fan:SystemModel | 1.057668 | 1.27300372 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 09:00:00 | 28863.95 | 28863.95 | 1.0000 | 1.27300372 | 1.057668 | 12.24 | 8.61 | 0.00546237 | 26087.0 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 28863.95 | -10.70 | 0.00150390 | -10.70 | 0.12033533 | 11.3774 | 21.05 | 0.00698167 | 21.10 | 0.00698167 | 44.9212 | 12871.13 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE COOLING COIL | Coil:Cooling:DX:MultiSpeed | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | CoolingDesignCapacity | N/A | No | No | unknown | No | 61276.460 | 0.000 | 2.575110 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.5215 | 1004.8586 | 1.2036 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 14:40:00 | 61276.46 | 49987.13 | 1.0000 | 3.09938947 | 2.575110 | 27.44 | 18.38 | 0.00951156 | 51845.8 | 12.00 | 11.25 | 0.00800000 | 32244.1 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 61276.46 | 32.10 | 0.01409687 | 23.10 | 0.35392745 | 13.7442 | 26.70 | 0.00878093 | 26.70 | 0.00878093 | 40.2271 | 32088.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PSZ-FINE STORAGE HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PSZ-FINE STORAGE | ZONE2 FINE STORAGE | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 87392.234 | 87392.234 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2036 | PSZ-FINE STORAGE_ADDAQ SUPPLY FAN | Fan:SystemModel | 2.575108 | 3.09938714 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | unknown | unknown | NEW.YORK-JOHN.F.KENNEDY.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB | 1/21 08:00:00 | 87392.23 | 87392.23 | 1.0000 | 3.09938714 | 2.575108 | 10.77 | 6.79 | 0.00451109 | 22198.2 | 40.00 | 21.14 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 87392.23 | -10.70 | 0.00150390 | -10.70 | 0.35392745 | 13.7442 | 15.55 | 0.00517956 | 15.54 | 0.00517956 | 47.3579 | 68575.61 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
None |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
None |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
ZONE1 OFFICE | 2774.00 | 2480.83 | 1794.83 |
ZONE2 FINE STORAGE | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 |
Facility | 2774.00 | 2480.83 | 1794.83 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
ZONE1 OFFICE | 85.83 | 18.17 | 52.33 | 17.83 |
ZONE2 FINE STORAGE | 493.50 | 40.50 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 549.00 | 58.67 | 52.33 | 17.83 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.74 | 5.00 | 1010.76 | 0.408 | 0.420 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
ZONE1 OFFICE | 3.74 | 5.00 | 1010.76 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Surfaces by ClassTotal | Outdoors | |
Wall | 16 | 10 |
Floor | 4 | 3 |
Roof | 3 | 2 |
Internal Mass | 1 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 14 | 14 |
Door | 28 | 28 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 2 |
Conditioned Zones | 3 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 0 |
Count | |
IDF Objects | 0 |
Defaulted Fields | 0 |
Fields with Defaults | 0 |
Autosized Fields | 0 |
Autosizable Fields | 0 |
Autocalculated Fields | 0 |
Autocalculatable Fields | 0 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
Electricity:Building | 617.95 | 4938.86 | 01-JAN-00:10 | 47606.95 | 19-JUN-09:10 |
Electricity:Zone:ZONE1 OFFICE | 62.57 | 1027.15 | 01-JAN-00:10 | 3852.05 | 02-JAN-08:10 |
InteriorLights:Electricity | 476.13 | 4365.11 | 01-JAN-00:10 | 35189.04 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE1 OFFICE | 30.62 | 453.40 | 01-JAN-00:10 | 1939.55 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity | 476.13 | 4365.11 | 01-JAN-00:10 | 35189.04 | 02-JAN-09:10 |
Electricity:Zone:ZONE2 FINE STORAGE | 135.00 | 1185.36 | 01-JAN-00:10 | 10075.60 | 02-JAN-09:10 |
InteriorLights:Electricity:Zone:ZONE2 FINE STORAGE | 135.00 | 1185.36 | 01-JAN-00:10 | 10075.60 | 02-JAN-09:10 |
Electricity:Zone:ZONE3 BULK STORAGE | 420.38 | 2726.34 | 01-JAN-00:10 | 33679.30 | 19-JUN-09:10 |
InteriorLights:Electricity:Zone:ZONE3 BULK STORAGE | 310.51 | 2726.34 | 01-JAN-00:10 | 23173.88 | 02-JAN-09:10 |
InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE1 OFFICE | 31.95 | 573.75 | 01-JAN-00:10 | 1912.50 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 139.28 | 573.75 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:ZONE3 BULK STORAGE | 107.34 | 0.00 | 01-JAN-00:10 | 8200.12 | 02-JAN-08:10 |
Electricity:Plant | 25.50 | 483.00 | 01-JAN-01:20 | 2477.26 | 06-FEB-12:50 |
WaterSystems:Electricity | 25.50 | 483.00 | 01-JAN-01:20 | 2477.26 | 06-FEB-12:50 |
Water Heater:WaterSystems:Electricity | 25.50 | 483.00 | 01-JAN-01:20 | 2477.26 | 06-FEB-12:50 |
Fans:Electricity | 60.59 | 0.00 | 17-JAN-18:10 | 6329.62 | 19-JUN-09:20 |
Fans:Electricity:Zone:ZONE3 BULK STORAGE | 2.54 | 0.00 | 01-JAN-00:10 | 2305.29 | 16-JUL-15:30 |
Ventilation (simple):Fans:Electricity | 2.54 | 0.00 | 01-JAN-00:10 | 2305.29 | 16-JUL-15:30 |
ElectricityPurchased:Facility | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
ElectricityPurchased:Plant | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
Cogeneration:ElectricityPurchased | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
ElectricityNet:Plant | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
Cogeneration:ElectricityNet | 862.41 | 5421.86 | 19-FEB-09:20 | 72235.72 | 04-AUG-14:10 |
Electricity:HVAC | 95.60 | 0.00 | 17-JAN-18:10 | 23686.23 | 19-JUN-12:00 |
General:Fans:Electricity | 58.05 | 0.00 | 17-JAN-18:10 | 4476.01 | 06-JAN-16:50 |
Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cooling:Electricity | 37.55 | 0.00 | 01-JAN-00:10 | 19661.90 | 19-JUN-12:00 |
ExteriorLights:Electricity | 123.36 | 0.00 | 01-JAN-07:30 | 7857.00 | 01-JAN-00:10 |
General:ExteriorLights:Electricity | 123.36 | 0.00 | 01-JAN-07:30 | 7857.00 | 01-JAN-00:10 |
Gas Annual Value [GJ] | Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Gas:Facility | 857.22 | 5000.00 | 17-JAN-18:10 | 354750.05 | 06-FEB-01:00 |
Gas:HVAC | 857.22 | 5000.00 | 17-JAN-18:10 | 354750.05 | 06-FEB-01:00 |
Heating:Gas | 857.22 | 5000.00 | 17-JAN-18:10 | 354750.05 | 06-FEB-01:00 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:Water | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Facility | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
MainsWater:Plant | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Water Heater:WaterSystems:MainsWater | 51.61 | 0.00 | 02-JAN-00:10 | 0.00 | 02-JAN-12:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
PlantLoopHeatingDemand:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
PlantLoopHeatingDemand:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:Facility | 1261.28 | 0.00 | 17-JAN-18:10 | 549725.15 | 06-FEB-01:00 |
EnergyTransfer:Building | 596.71 | 0.00 | 17-JAN-18:10 | 270042.01 | 06-FEB-01:00 |
EnergyTransfer:Zone:ZONE1 OFFICE | 62.48 | 0.00 | 01-JAN-00:40 | 25375.69 | 06-FEB-07:10 |
Heating:EnergyTransfer | 512.01 | 0.00 | 17-JAN-18:10 | 270042.01 | 06-FEB-01:00 |
Heating:EnergyTransfer:Zone:ZONE1 OFFICE | 34.26 | 0.00 | 01-JAN-00:40 | 25375.69 | 06-FEB-07:10 |
Cooling:EnergyTransfer | 84.70 | 0.00 | 01-JAN-00:10 | 44054.13 | 18-AUG-15:10 |
Cooling:EnergyTransfer:Zone:ZONE1 OFFICE | 28.23 | 0.00 | 01-JAN-00:10 | 11711.76 | 10-JUL-05:10 |
EnergyTransfer:Zone:ZONE2 FINE STORAGE | 231.45 | 0.00 | 01-JAN-00:40 | 78162.13 | 06-FEB-06:10 |
Heating:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 174.97 | 0.00 | 01-JAN-00:40 | 78162.13 | 06-FEB-06:10 |
Cooling:EnergyTransfer:Zone:ZONE2 FINE STORAGE | 56.48 | 0.00 | 01-JAN-00:10 | 33959.09 | 18-AUG-15:10 |
EnergyTransfer:Zone:ZONE3 BULK STORAGE | 302.78 | 0.00 | 02-JAN-10:50 | 186081.14 | 06-FEB-01:00 |
Heating:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 302.78 | 0.00 | 02-JAN-10:50 | 186081.14 | 06-FEB-01:00 |
Cooling:EnergyTransfer:Zone:ZONE3 BULK STORAGE | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
EnergyTransfer:HVAC | 664.57 | 0.00 | 17-JAN-18:10 | 279683.14 | 06-FEB-01:00 |
HeatingCoils:EnergyTransfer | 530.00 | 0.00 | 17-JAN-18:10 | 279683.14 | 06-FEB-01:00 |
CoolingCoils:EnergyTransfer | 134.57 | 0.00 | 01-JAN-00:10 | 68679.06 | 02-AUG-15:30 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
ZONE1 OFFICE | 0.000 | 0.000 | 34.256 | -28.225 | 0.000 | 0.000 | 3.902 | 30.619 | 31.946 | 9.851 | 0.000 | 1.155 | 0.000 | 0.000 | -8.926 | 0.000 | -26.085 | -48.493 |
ZONE2 FINE STORAGE | 0.000 | 0.000 | 174.973 | -56.474 | 0.000 | 0.000 | 0.000 | 135.003 | 0.000 | 0.000 | 0.000 | 2.172 | 0.002 | 0.000 | 0.000 | 0.000 | -175.160 | -80.514 |
ZONE3 BULK STORAGE | 302.775 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 310.507 | 107.336 | 19.968 | 0.000 | 6.453 | 0.000 | 0.000 | -8.390 | 0.000 | -614.965 | -123.684 |
Total Facility | 302.775 | 0.000 | 209.229 | -84.699 | 0.000 | 0.000 | 3.902 | 476.129 | 139.282 | 29.819 | 0.000 | 9.780 | 0.002 | 0.000 | -17.316 | 0.000 | -816.210 | -252.691 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 25-AUG-05:01 | 0.00 | 0.00 | 0.00 | -19857.59 | 0.00 | 0.00 | 31.64 | 579.35 | 573.75 | 0.00 | 0.00 | 0.00 | 19715.55 | 0.00 | -398.97 | 0.00 | -643.73 | 0.00 |
ZONE2 FINE STORAGE | 20-AUG-15:13 | 0.00 | 0.00 | 0.00 | -55340.11 | 0.00 | 0.00 | 0.00 | 1185.36 | 0.00 | 0.00 | 0.00 | 62.86 | 54091.89 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 20-AUG-15:13 | 0.00 | 0.00 | 0.00 | -55340.11 | 0.00 | 0.00 | 0.00 | 4365.11 | 573.75 | 4350.00 | 0.00 | 62.86 | 149803.25 | 0.00 | 0.00 | 0.00 | -103814.86 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
ZONE1 OFFICE | 24-JAN-06:01 | 0.00 | 0.00 | 28404.83 | 0.00 | 0.00 | 0.00 | 57.34 | 579.35 | 573.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -251.85 | 0.00 | -933.98 | -28429.45 |
ZONE2 FINE STORAGE | 12-JAN-04:02 | 0.00 | 0.00 | 87019.30 | 0.00 | 0.00 | 0.00 | 0.00 | 1185.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -15411.28 | -72793.39 |
ZONE3 BULK STORAGE | 06-FEB-00:51 | 186085.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -1169.08 | 0.00 | -147034.00 | -42658.45 |
Total Facility | 06-FEB-00:51 | 186085.17 | 0.00 | 84721.68 | 0.00 | 0.00 | 0.00 | 0.00 | 4365.11 | 2623.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2413.15 | 0.00 | -189172.57 | -86210.01 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.0577 | 0.0000 | 5.0000 | 1.0000 | 0.1203 | 1.0577 | 0.1138 | 1.0000 | 0.1203 | 0.1138 | ||
PSZ-FINE STORAGE | 2.5751 | 0.0000 | 0.0000 | 1.0000 | 0.3539 | 2.5751 | 0.1374 | 1.0000 | 0.3539 | 0.1374 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PSZ-OFFICE | 1.0577 | 0.0000 | 5.0000 | 1.0000 | 0.1203 | 1.0577 | 1.0000 | 1.0000 | 0.1203 | 0.1138 | ||
PSZ-FINE STORAGE | 2.5751 | 0.0000 | 0.0000 | 1.0000 | 0.3539 | 2.5751 | 1.0000 | 1.0000 | 0.3539 | 0.1374 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
ZONE1 OFFICE | PSZ-OFFICE | 0.000000 | 5.0000 | 0.000508 | 236.88 | 0.1203 | 1.0000 | 0.1203 | 1.000 | 0.1203 |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 0.000000 | 0.0000 | 0.000254 | 1393.41 | 0.3539 | 1.0000 | 0.3539 | 1.000 | 0.3539 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PSZ-OFFICE | 0.000000 | 5.00 | 0.000508 | 236.8796 | 0.1203 | 0.1203 | 0.1203 |
PSZ-FINE STORAGE | 0.00 | 0.000254 | 1393.4097 | 0.3539 | 0.3539 | 0.3539 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 1.0577 | 1.0577 | 1.0577 | 0.1203 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 2.5751 | 2.5751 | 2.5751 | 0.3539 | 0.0000 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.0577 | 1.0577 | 1.0577 | 1.0577 | 0.1203 | 1.0000 |
PSZ-FINE STORAGE | 2.5751 | 2.5751 | 2.5751 | 2.5751 | 0.3539 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
ZONE1 OFFICE | PSZ-OFFICE | 1.0577 | 1.0577 | 1.0577 | 0.1203 | 0.2774 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 | |
ZONE2 FINE STORAGE | PSZ-FINE STORAGE | 2.5751 | 2.5751 | 2.5751 | 0.3539 | 0.1819 | 1.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PSZ-OFFICE | 1.0577 | 1.0577 | 1.0577 | 1.0577 | 0.1203 | 1.0000 |
PSZ-FINE STORAGE | 2.5751 | 2.5751 | 2.5751 | 2.5751 | 0.3539 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2020-06-03 19:11:33
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** New York-John F Kennedy Intl AP NY USA TMY3 WMO#=744860 |
Total gross floor area [m2] | 4835.13 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
ZONE1 OFFICE | 236.88 | 236.88 | 0.00 | 69.73 |
ZONE2 FINE STORAGE | 1393.41 | 1393.41 | 0.00 | 0.00 |
ZONE3 BULK STORAGE | 3204.84 | 3204.84 | 0.00 | 0.00 |
Totals | 4835.13 | 4835.13 | 0.00 |
Data | |
Number of hours heating loads not met | 52.33 |
Number of hours cooling loads not met | 17.83 |
Number of hours not met | 70.17 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electric Energy Use [GJ] | Electric Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Additional Fuel Use [GJ] | Additional Fuel Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- Not Subdivided | 0.00 | 0.00 | 857.22 | 354750.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- Not Subdivided | 37.55 | 19661.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 476.13 | 35189.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 123.36 | 7857.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 139.28 | 10112.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- Ventilation (simple) | 2.54 | 2305.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 58.05 | 4476.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 25.50 | 2477.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 139.28 | 862.41 |
Natural Gas | 0.00 | 857.22 |
Additional | 0.00 | 0.00 |
Total | 139.28 | 1719.63 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 98.47 |
Space Heating | 0.00 |
Space Cooling | 7.77 |
Fans (All) | 12.53 |
Service Water Heating | 5.27 |
Receptacle Equipment | 28.81 |
Miscellaneous (All) | 178.36 |
Subtotal | 178.36 |
Natural Gas [MJ/m2] | |
Space Heating | 177.29 |
Service Water Heating | 0.00 |
Miscellaneous (All) | 177.29 |
Subtotal | 177.29 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 27.69 |
Space Heating | 49.85 |
Space Cooling | 2.18 |
Fans (All) | 3.52 |
Service Water Heating | 1.48 |
Receptacle Equipment | 8.10 |
Miscellaneous | 7.17 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
OFFICE LIGHT SCHEDULE | 3792. | 8760. |
OFFICE PEOPLE SCHEDULE | 2861. | 3744. |
OFFICE DHW SCHEDULE | 1825. | 5016. |
STORAGE LIGHT SCHEDULE | 3232. | 8760. |
BULK STORAGE PLUG SCHEDULE | 3744. | 7488. |
EXTERIOR LIGHT SCHEDULE | 5475. | 5475. |
OFFICE LIGHT WITH SENSOR SCHEDULE | 3430. | 8760. |
STORAGE LIGHT WITH SENSOR SCHEDULE | 2877. | 8760. |
OFFICE_PLUG_SCH | 4700. | 8760. |
BLDG_LIGHT_OFFICE_SCH | 3430. | 8760. |
BLDG_LIGHT_STORAGE_SCH | 3232. | 8760. |
BLDG_OCC_SCH | 2861. | 3744. |
FANSCHED | 3432. | 3432. |
MINOA_MOTORIZEDDAMPER_SCHED | 3120. | 3120. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 5550. | 8760. |
ALWAYS OFF SCHEDULE | 0. | 0. |
OA DAMPER OFF DURING OFF HRS SCHEDULE | 2808. | 2808. |
OA DAMPER ALWAYS ON SCHEDULE | 8760. | 8760. |
MINOA_SCHED | 8760. | 8760. |
ALWAYS ON SCHEDULE | 8760. | 8760. |
EXTERIOR_LTG_SCH | 4380. | 4380. |
INFIL_DOOR_OPENING_SCH | 1154. | 3380. |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 2600. | 2600. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6935. | 8760. |
SZ_SYSTEM_OA_MAX_FRAC_SCH | 6132. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
BULK STORAGE HEATING SETPOINT SCHEDULE | HEATING SETPOINT WITH SB | January | 10.00 | 365 | 10.00 | 365 |
OFFICE HEATING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | January | 21.10 | 365 | 15.60 | 365 |
OFFICE COOLING SCHEDULE | OFFICE THERMOSTAT DUAL SP CONTROL | July | 23.90 | 365 | 29.40 | 365 |
FINE STORAGE HEATING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | January | 15.56 | 365 | 15.56 | 365 |
FINE STORAGE COOLING SETPOINT SCHEDULE | FINE STORAGE THERMOSTAT DUAL SP CONTROL | July | 26.70 | 365 | 26.70 | 365 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME IECC
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2006
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME WAREHOUSE
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 4A
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_NY_NEWYORK
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB [] | HEATING:GAS [J] | |
January | 0.000 | 0.224388E+12 |
February | 0.000 | 0.214211E+12 |
March | 0.000 | 0.880676E+11 |
April | 0.000 | 0.273972E+11 |
May | 0.000 | 0.139506E+11 |
June | 0.000 | 0.129600E+11 |
July | 0.000 | 0.133920E+11 |
August | 0.000 | 0.133920E+11 |
September | 0.000 | 0.129600E+11 |
October | 0.000 | 0.142514E+11 |
November | 0.000 | 0.692219E+11 |
December | 0.000 | 0.153030E+12 |
Annual Sum or Average | 0.857222E+12 | |
Minimum of Months | 0.000 | 0.129600E+11 |
Maximum of Months | 0.000 | 0.224388E+12 |
Report: ZoneCoolingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 191216.78 | 1274.78 | 07-JAN-07:05 | 1.70 | -0.8 | 0.194952E+09 | 236.59 | 21-JAN-11:09 | 6.47 | 6.07 |
February | 0.00 | 0.00 | 01-FEB-00:02 | -1.1 | -4.0 | 0.179331E+09 | 236.59 | 04-FEB-08:20 | 0.60 | 0.37 |
March | 17900386.11 | 898.59 | 29-MAR-15:00 | 7.20 | 5.19 | 0.212191E+09 | 293.54 | 27-MAR-15:00 | 22.20 | 16.33 |
April | 0.238479E+09 | 3130.70 | 07-APR-16:00 | 25.60 | 16.11 | 0.210024E+09 | 302.38 | 27-APR-12:00 | 17.80 | 14.45 |
May | 0.142561E+10 | 16313.26 | 31-MAY-05:03 | 16.38 | 14.98 | 0.246613E+09 | 301.60 | 30-MAY-10:50 | 28.72 | 17.31 |
June | 0.527913E+10 | 18241.25 | 23-JUN-05:01 | 20.68 | 16.41 | 0.258809E+09 | 301.61 | 03-JUN-15:00 | 19.40 | 14.49 |
July | 0.722760E+10 | 17779.15 | 11-JUL-05:01 | 19.60 | 15.10 | 0.249069E+09 | 301.61 | 12-JUL-13:00 | 28.30 | 19.50 |
August | 0.797621E+10 | 19857.43 | 25-AUG-05:01 | 18.72 | 13.38 | 0.268986E+09 | 301.61 | 23-AUG-15:00 | 25.60 | 17.53 |
September | 0.456376E+10 | 19063.81 | 02-SEP-05:01 | 22.12 | 16.29 | 0.248164E+09 | 301.61 | 02-SEP-14:30 | 25.00 | 18.12 |
October | 0.147043E+10 | 5691.27 | 04-OCT-15:30 | 23.35 | 19.11 | 0.235655E+09 | 301.59 | 06-OCT-14:20 | 16.87 | 10.76 |
November | 26437752.82 | 902.10 | 04-NOV-14:10 | 16.78 | 12.90 | 0.193005E+09 | 301.58 | 04-NOV-14:09 | 16.78 | 12.90 |
December | 286082.10 | 1907.21 | 02-DEC-07:05 | 1.10 | -2.0 | 0.194942E+09 | 236.59 | 29-DEC-16:10 | 5.18 | 4.91 |
Annual Sum or Average | 0.282260E+11 | 0.269174E+10 | ||||||||
Minimum of Months | 0.00 | 0.00 | -1.1 | -4.0 | 0.179331E+09 | 236.59 | 0.60 | 0.37 | ||
Maximum of Months | 0.797621E+10 | 19857.43 | 25.60 | 19.11 | 0.268986E+09 | 302.38 | 28.72 | 19.50 |
Report: ZoneCoolingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.178660E+09 | 3095.83 | 31-JAN-16:00 | -1.1 | -5.4 | 0.00 | 0.00 | 01-JAN-00:10 | -9.6 | -11.4 |
February | 0.280101E+09 | 3305.87 | 03-FEB-14:00 | -0.6 | -4.4 | 0.00 | 0.00 | 01-FEB-00:10 | -1.1 | -4.0 |
March | 0.575845E+09 | 4294.44 | 18-MAR-10:00 | 0.00 | -0.7 | 0.00 | 0.00 | 01-MAR-00:10 | 5.52 | 4.34 |
April | 0.371982E+09 | 2863.26 | 12-APR-08:15 | 5.97 | 0.45 | 0.00 | 0.00 | 01-APR-00:10 | 5.27 | 4.90 |
May | 0.986133E+09 | 20164.81 | 29-MAY-13:30 | 26.65 | 17.20 | 0.00 | 0.00 | 01-MAY-00:10 | 10.33 | 9.91 |
June | 0.891630E+10 | 50897.23 | 22-JUN-17:08 | 29.32 | 17.48 | 0.00 | 0.00 | 01-JUN-00:10 | 18.37 | 16.58 |
July | 0.181900E+11 | 52648.58 | 11-JUL-17:06 | 28.12 | 17.26 | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 | 19.28 |
August | 0.200918E+11 | 55341.66 | 20-AUG-15:13 | 27.07 | 16.27 | 0.00 | 0.00 | 01-AUG-00:10 | 23.90 | 21.46 |
September | 0.593320E+10 | 50115.64 | 04-SEP-13:13 | 26.10 | 18.35 | 0.00 | 0.00 | 01-SEP-00:10 | 23.43 | 19.79 |
October | 0.542725E+09 | 6622.96 | 04-OCT-14:10 | 24.32 | 18.97 | 0.00 | 0.00 | 01-OCT-00:10 | 12.47 | 11.77 |
November | 0.199797E+09 | 4155.35 | 20-NOV-07:05 | 0.18 | -0.9 | 0.00 | 0.00 | 01-NOV-00:10 | 10.40 | 9.04 |
December | 0.209558E+09 | 3036.37 | 09-DEC-11:00 | 3.30 | 0.82 | 0.00 | 0.00 | 01-DEC-00:10 | 5.97 | 2.85 |
Annual Sum or Average | 0.564761E+11 | 0.00 | ||||||||
Minimum of Months | 0.178660E+09 | 2863.26 | -1.1 | -5.4 | 0.00 | 0.00 | -9.6 | -11.4 | ||
Maximum of Months | 0.200918E+11 | 55341.66 | 29.32 | 18.97 | 0.00 | 0.00 | 23.90 | 21.46 |
Report: ZoneCoolingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum}[W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:01 | -9.6 | -11.4 | 0.00 | 0.00 | 01-JAN-00:10 | -9.6 | -11.4 |
February | 0.00 | 0.00 | 01-FEB-00:02 | -1.1 | -4.0 | 0.00 | 0.00 | 01-FEB-00:10 | -1.1 | -4.0 |
March | 0.00 | 0.00 | 01-MAR-00:03 | 5.52 | 4.34 | 0.00 | 0.00 | 01-MAR-00:10 | 5.52 | 4.34 |
April | 0.00 | 0.00 | 01-APR-00:10 | 5.27 | 4.90 | 0.00 | 0.00 | 01-APR-00:10 | 5.27 | 4.90 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.33 | 9.91 | 0.00 | 0.00 | 01-MAY-00:10 | 10.33 | 9.91 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 18.37 | 16.58 | 0.00 | 0.00 | 01-JUN-00:10 | 18.37 | 16.58 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 | 19.28 | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 | 19.28 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 23.90 | 21.46 | 0.00 | 0.00 | 01-AUG-00:10 | 23.90 | 21.46 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 23.43 | 19.79 | 0.00 | 0.00 | 01-SEP-00:10 | 23.43 | 19.79 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 12.47 | 11.77 | 0.00 | 0.00 | 01-OCT-00:10 | 12.47 | 11.77 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 10.40 | 9.04 | 0.00 | 0.00 | 01-NOV-00:10 | 10.40 | 9.04 |
December | 0.00 | 0.00 | 01-DEC-00:03 | 5.97 | 2.85 | 0.00 | 0.00 | 01-DEC-00:10 | 5.97 | 2.85 |
Annual Sum or Average | 0.00 | 0.00 | ||||||||
Minimum of Months | 0.00 | 0.00 | -9.6 | -11.4 | 0.00 | 0.00 | -9.6 | -11.4 | ||
Maximum of Months | 0.00 | 0.00 | 23.90 | 21.46 | 0.00 | 0.00 | 23.90 | 21.46 |
Report: ZoneHeatingSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.823648E+10 | 28404.70 | 24-JAN-06:01 | 11.10 |
February | 0.801919E+10 | 27726.03 | 14-FEB-06:31 | -4.4 |
March | 0.516928E+10 | 28023.62 | 06-MAR-06:01 | 8.30 |
April | 0.226352E+10 | 28130.15 | 07-APR-05:01 | 14.82 |
May | 0.409757E+09 | 28052.87 | 08-MAY-05:01 | 12.83 |
June | 10873209.97 | 800.92 | 08-JUN-06:10 | 20.28 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 263873.74 | 439.79 | 08-AUG-06:10 | 17.57 |
September | 12920578.34 | 755.99 | 21-SEP-06:10 | 19.50 |
October | 0.410677E+09 | 28115.63 | 30-OCT-05:01 | 11.93 |
November | 0.359056E+10 | 28085.19 | 10-NOV-06:01 | 14.60 |
December | 0.613240E+10 | 28086.79 | 07-DEC-06:31 | 0.40 |
Annual Sum or Average | 0.342559E+11 | |||
Minimum of Months | 0.00 | 0.00 | -4.4 | |
Maximum of Months | 0.823648E+10 | 28404.70 | 20.28 |
Report: ZoneHeatingSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.473512E+11 | 87020.70 | 12-JAN-04:02 | 5.22 |
February | 0.436020E+11 | 85346.42 | 11-FEB-22:42 | 0.78 |
March | 0.224033E+11 | 86010.81 | 21-MAR-20:22 | 2.25 |
April | 0.670443E+10 | 84317.29 | 02-APR-21:53 | 5.60 |
May | 0.425863E+09 | 57963.95 | 02-MAY-05:01 | 8.40 |
June | 80848617.05 | 1833.10 | 19-JUN-06:05 | 25.37 |
July | 10793456.94 | 1120.18 | 03-JUL-06:05 | 23.17 |
August | 15375019.12 | 986.92 | 11-AUG-06:05 | 22.98 |
September | 0.102211E+09 | 1844.69 | 22-SEP-15:20 | 21.87 |
October | 0.487884E+09 | 30444.95 | 31-OCT-05:38 | 5.20 |
November | 0.179137E+11 | 85485.17 | 26-NOV-08:62 | 8.98 |
December | 0.358759E+11 | 86757.97 | 29-DEC-22:02 | 4.40 |
Annual Sum or Average | 0.174973E+12 | |||
Minimum of Months | 10793456.94 | 986.92 | 0.78 | |
Maximum of Months | 0.473512E+11 | 87020.70 | 25.37 |
Report: ZoneHeatingSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.100683E+12 | 160553.20 | 01-JAN-20:54 | -8.3 |
February | 0.976231E+11 | 186085.26 | 06-FEB-00:51 | -13.3 |
March | 0.253800E+11 | 107588.18 | 22-MAR-07:10 | -2.7 |
April | 0.804772E+09 | 23546.00 | 02-APR-05:55 | 3.30 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 10.33 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 18.37 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 20.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 23.90 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 23.43 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 12.47 |
November | 0.185240E+11 | 104837.80 | 23-NOV-01:52 | -2.8 |
December | 0.597611E+11 | 163241.10 | 31-DEC-21:52 | -7.2 |
Annual Sum or Average | 0.302776E+12 | |||
Minimum of Months | 0.00 | 0.00 | -13.3 | |
Maximum of Months | 0.100683E+12 | 186085.26 | 23.90 |
Report: ZoneElectricSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.256100E+10 | 1939.55 | 02-JAN-08:09 | 0.267964E+10 | 1912.50 | 02-JAN-08:09 |
February | 0.233575E+10 | 1939.55 | 01-FEB-08:09 | 0.243949E+10 | 1912.50 | 01-FEB-08:09 |
March | 0.266872E+10 | 1939.55 | 01-MAR-08:09 | 0.277107E+10 | 1912.50 | 01-MAR-08:09 |
April | 0.252182E+10 | 1939.55 | 01-APR-07:10 | 0.263007E+10 | 1912.50 | 01-APR-07:10 |
May | 0.261486E+10 | 1939.55 | 01-MAY-07:10 | 0.272536E+10 | 1912.50 | 01-MAY-07:10 |
June | 0.257569E+10 | 1939.55 | 01-JUN-07:10 | 0.267579E+10 | 1912.50 | 01-JUN-07:10 |
July | 0.256100E+10 | 1939.55 | 01-JUL-07:10 | 0.267964E+10 | 1912.50 | 01-JUL-07:10 |
August | 0.266872E+10 | 1939.55 | 01-AUG-07:10 | 0.277107E+10 | 1912.50 | 01-AUG-07:10 |
September | 0.252182E+10 | 1939.55 | 01-SEP-07:10 | 0.263007E+10 | 1912.50 | 01-SEP-07:10 |
October | 0.256100E+10 | 1939.55 | 02-OCT-07:10 | 0.267964E+10 | 1912.50 | 02-OCT-07:10 |
November | 0.246796E+10 | 1939.55 | 01-NOV-07:10 | 0.258435E+10 | 1912.50 | 01-NOV-07:10 |
December | 0.256100E+10 | 1939.55 | 01-DEC-08:09 | 0.267964E+10 | 1912.50 | 01-DEC-08:09 |
Annual Sum or Average | 0.306193E+11 | 0.319458E+11 | ||||
Minimum of Months | 0.233575E+10 | 1939.55 | 0.243949E+10 | 1912.50 | ||
Maximum of Months | 0.266872E+10 | 1939.55 | 0.277107E+10 | 1912.50 |
Report: ZoneElectricSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [] | |
January | 0.112294E+11 | 10075.60 | 02-JAN-09:09 | 0.00 | 0.00 |
February | 0.102778E+11 | 10075.60 | 01-FEB-09:09 | 0.00 | 0.00 |
March | 0.118738E+11 | 10075.60 | 01-MAR-09:09 | 0.00 | 0.00 |
April | 0.111270E+11 | 10075.60 | 01-APR-08:09 | 0.00 | 0.00 |
May | 0.115516E+11 | 10075.60 | 01-MAY-08:09 | 0.00 | 0.00 |
June | 0.114492E+11 | 10075.60 | 01-JUN-08:09 | 0.00 | 0.00 |
July | 0.112294E+11 | 10075.60 | 01-JUL-08:09 | 0.00 | 0.00 |
August | 0.118738E+11 | 10075.60 | 01-AUG-08:09 | 0.00 | 0.00 |
September | 0.111270E+11 | 10075.60 | 01-SEP-08:09 | 0.00 | 0.00 |
October | 0.112294E+11 | 10075.60 | 02-OCT-08:09 | 0.00 | 0.00 |
November | 0.108048E+11 | 10075.60 | 01-NOV-08:09 | 0.00 | 0.00 |
December | 0.112294E+11 | 10075.60 | 01-DEC-09:09 | 0.00 | 0.00 |
Annual Sum or Average | 0.135003E+12 | ||||
Minimum of Months | 0.102778E+11 | 10075.60 | 0.00 | 0.00 | |
Maximum of Months | 0.118738E+11 | 10075.60 | 0.00 | 0.00 |
Report: ZoneElectricSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE LIGHTS ELECTRIC ENERGY [J] | ZONE LIGHTS ELECTRIC ENERGY {Maximum}[W] | ZONE LIGHTS ELECTRIC ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT ELECTRIC ENERGY {TIMESTAMP} | |
January | 0.258277E+11 | 23173.88 | 02-JAN-09:09 | 0.885613E+10 | 8200.12 | 02-JAN-08:09 |
February | 0.236390E+11 | 23173.88 | 01-FEB-09:09 | 0.814764E+10 | 8200.12 | 01-FEB-08:09 |
March | 0.273097E+11 | 23173.88 | 01-MAR-09:09 | 0.956462E+10 | 8200.12 | 01-MAR-08:09 |
April | 0.255921E+11 | 23173.88 | 01-APR-08:09 | 0.885613E+10 | 8200.12 | 01-APR-07:10 |
May | 0.265687E+11 | 23173.88 | 01-MAY-08:09 | 0.921037E+10 | 8200.12 | 01-MAY-07:10 |
June | 0.263332E+11 | 23173.88 | 01-JUN-08:09 | 0.921037E+10 | 8200.12 | 01-JUN-07:10 |
July | 0.258277E+11 | 23173.88 | 01-JUL-08:09 | 0.885613E+10 | 8200.12 | 01-JUL-07:10 |
August | 0.273097E+11 | 23173.88 | 01-AUG-08:09 | 0.956462E+10 | 8200.12 | 01-AUG-07:10 |
September | 0.255921E+11 | 23173.88 | 01-SEP-08:09 | 0.885613E+10 | 8200.12 | 01-SEP-07:10 |
October | 0.258277E+11 | 23173.88 | 02-OCT-08:09 | 0.885613E+10 | 8200.12 | 02-OCT-07:10 |
November | 0.248511E+11 | 23173.88 | 01-NOV-08:09 | 0.850188E+10 | 8200.12 | 01-NOV-07:10 |
December | 0.258277E+11 | 23173.88 | 01-DEC-09:09 | 0.885613E+10 | 8200.12 | 01-DEC-08:09 |
Annual Sum or Average | 0.310507E+12 | 0.107336E+12 | ||||
Minimum of Months | 0.236390E+11 | 23173.88 | 0.814764E+10 | 8200.12 | ||
Maximum of Months | 0.273097E+11 | 23173.88 | 0.956462E+10 | 8200.12 |
Report: SpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.448664E+10 |
February | 0.500553E+09 | 0.233575E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.427289E+10 |
March | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.356579E+10 |
April | 0.544079E+09 | 0.252182E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8626877.46 | 0.207724E+10 |
May | 0.565842E+09 | 0.261486E+10 | 0.272536E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25694703.32 | 0.131208E+10 |
June | 0.565842E+09 | 0.257569E+10 | 0.267579E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.182469E+09 | 0.652163E+09 |
July | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.380093E+09 | 0.211223E+09 |
August | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.477979E+09 | 0.289601E+09 |
September | 0.544079E+09 | 0.252182E+10 | 0.263007E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 79058574.19 | 0.745864E+09 |
October | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1423531.23 | 0.167678E+10 |
November | 0.522316E+09 | 0.246796E+10 | 0.258435E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295091E+10 |
December | 0.544079E+09 | 0.256100E+10 | 0.267964E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.384372E+10 |
Annual Sum or Average | 0.659424E+10 | 0.306193E+11 | 0.319458E+11 | 0.115534E+10 | 0.260849E+11 | ||||
Minimum of Months | 0.500553E+09 | 0.233575E+10 | 0.243949E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.211223E+09 |
Maximum of Months | 0.587605E+09 | 0.266872E+10 | 0.277107E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.477979E+09 | 0.448664E+10 |
Report: SpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.315037E+11 |
February | 0.00 | 0.102778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.287441E+11 |
March | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2144803.50 | 0.211446E+11 |
April | 0.00 | 0.111270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51780637.33 | 0.118317E+11 |
May | 0.00 | 0.115516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29816339.78 | 0.802090E+10 |
June | 0.00 | 0.114492E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.339227E+09 | 0.669053E+10 |
July | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.637524E+09 | 0.276919E+10 |
August | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103641E+10 | 0.327108E+10 |
September | 0.00 | 0.111270E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 75138278.45 | 0.642006E+10 |
October | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.109588E+11 |
November | 0.00 | 0.108048E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.179670E+11 |
December | 0.00 | 0.112294E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.258384E+11 |
Annual Sum or Average | 0.135003E+12 | 0.217204E+10 | 0.175160E+12 | ||||||
Minimum of Months | 0.00 | 0.102778E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.276919E+10 |
Maximum of Months | 0.00 | 0.118738E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.103641E+10 | 0.315037E+11 |
Report: SpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26328575.58 | 0.683626E+11 |
February | 0.00 | 0.236390E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.670254E+11 |
March | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.640927E+09 | 0.400547E+11 |
April | 0.00 | 0.255921E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167346E+10 | 0.243703E+11 |
May | 0.00 | 0.265687E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.332791E+09 | 0.207757E+11 |
June | 0.00 | 0.263332E+11 | 0.921037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.245254E+09 | 0.266547E+11 |
July | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 13313613.61 | 0.170083E+11 |
August | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38916011.42 | 0.190454E+11 |
September | 0.00 | 0.255921E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1057393.40 | 0.264538E+11 |
October | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 28670316.01 | 0.330501E+11 |
November | 0.00 | 0.248511E+11 | 0.850188E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 72059224.18 | 0.376748E+11 |
December | 0.00 | 0.258277E+11 | 0.885613E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11324462.98 | 0.505260E+11 |
Annual Sum or Average | 0.310507E+12 | 0.107336E+12 | 0.308410E+10 | 0.431002E+12 | |||||
Minimum of Months | 0.00 | 0.236390E+11 | 0.814764E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.170083E+11 |
Maximum of Months | 0.00 | 0.273097E+11 | 0.956462E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.167346E+10 | 0.683626E+11 |
Report: PeakSpaceGainsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum}[W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 659.25 | 02-JAN-08:09 | 1939.55 | 02-JAN-08:09 | 1912.50 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 14700.51 | 31-JAN-07:10 |
February | 659.25 | 01-FEB-08:09 | 1939.55 | 01-FEB-08:09 | 1912.50 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 16412.99 | 06-FEB-07:05 |
March | 659.25 | 01-MAR-08:09 | 1939.55 | 01-MAR-08:09 | 1912.50 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 12638.67 | 22-MAR-07:00 |
April | 659.25 | 01-APR-07:10 | 1939.55 | 01-APR-07:10 | 1912.50 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 902.18 | 07-APR-17:00 | 7841.36 | 12-APR-07:00 |
May | 659.25 | 01-MAY-07:10 | 1939.55 | 01-MAY-07:10 | 1912.50 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 1962.18 | 30-MAY-12:00 | 5543.03 | 01-MAY-06:05 |
June | 659.25 | 01-JUN-07:10 | 1939.55 | 01-JUN-07:10 | 1912.50 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4511.06 | 19-JUN-12:00 | 4068.39 | 02-JUN-06:05 |
July | 659.25 | 01-JUL-07:10 | 1939.55 | 01-JUL-07:10 | 1912.50 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3498.12 | 07-JUL-12:00 | 1185.43 | 11-JUL-06:10 |
August | 659.25 | 01-AUG-07:10 | 1939.55 | 01-AUG-07:10 | 1912.50 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4061.66 | 24-AUG-17:00 | 2455.02 | 08-AUG-06:10 |
September | 659.25 | 01-SEP-07:10 | 1939.55 | 01-SEP-07:10 | 1912.50 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2194.87 | 14-SEP-16:10 | 4789.41 | 11-SEP-06:05 |
October | 659.25 | 02-OCT-07:10 | 1939.55 | 02-OCT-07:10 | 1912.50 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 338.99 | 25-OCT-11:10 | 6802.88 | 18-OCT-06:10 |
November | 659.25 | 01-NOV-07:10 | 1939.55 | 01-NOV-07:10 | 1912.50 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 11190.13 | 22-NOV-07:10 |
December | 659.25 | 01-DEC-08:09 | 1939.55 | 01-DEC-08:09 | 1912.50 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 10730.15 | 22-DEC-07:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1185.43 | |||||
Maximum of Months | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 4511.06 | 16412.99 |
Report: PeakSpaceGainsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 10075.60 | 02-JAN-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 49629.42 | 14-JAN-17:00 |
February | 0.00 | 10075.60 | 01-FEB-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 44283.20 | 06-FEB-07:10 |
March | 0.00 | 10075.60 | 01-MAR-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 778.60 | 27-MAR-16:00 | 46838.52 | 22-MAR-07:00 |
April | 0.00 | 10075.60 | 01-APR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2172.61 | 16-APR-17:00 | 19972.51 | 21-APR-06:10 |
May | 0.00 | 10075.60 | 01-MAY-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1667.70 | 29-MAY-12:10 | 11713.47 | 11-MAY-16:05 |
June | 0.00 | 10075.60 | 01-JUN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7675.77 | 19-JUN-17:00 | 12315.77 | 06-JUN-15:05 |
July | 0.00 | 10075.60 | 01-JUL-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6792.81 | 10-JUL-15:10 | 5582.49 | 15-JUL-08:00 |
August | 0.00 | 10075.60 | 01-AUG-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11165.90 | 24-AUG-17:00 | 6246.17 | 20-AUG-06:00 |
September | 0.00 | 10075.60 | 01-SEP-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3476.25 | 01-SEP-15:10 | 7886.13 | 23-SEP-07:00 |
October | 0.00 | 10075.60 | 02-OCT-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 18372.26 | 07-OCT-15:03 |
November | 0.00 | 10075.60 | 01-NOV-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 32035.85 | 23-NOV-01:51 |
December | 0.00 | 10075.60 | 01-DEC-09:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 44463.95 | 31-DEC-21:51 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5582.49 | |||
Maximum of Months | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 11165.90 | 49629.42 |
Report: PeakSpaceGainsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum}[W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum}[W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum}[W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 23173.88 | 02-JAN-09:09 | 8200.12 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 2806.11 | 03-JAN-10:50 | 112510.55 | 14-JAN-17:00 |
February | 0.00 | 23173.88 | 01-FEB-09:09 | 8200.12 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 108146.06 | 06-FEB-00:54 |
March | 0.00 | 23173.88 | 01-MAR-09:09 | 8200.12 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 21244.63 | 27-MAR-16:00 | 96758.48 | 22-MAR-07:10 |
April | 0.00 | 23173.88 | 01-APR-08:09 | 8200.12 | 01-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 22894.25 | 07-APR-13:50 | 43090.54 | 12-APR-07:10 |
May | 0.00 | 23173.88 | 01-MAY-08:09 | 8200.12 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8172.37 | 29-MAY-11:55 | 25616.95 | 11-MAY-16:00 |
June | 0.00 | 23173.88 | 01-JUN-08:09 | 8200.12 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6956.51 | 07-JUN-14:00 | 30565.06 | 06-JUN-15:00 |
July | 0.00 | 23173.88 | 01-JUL-08:09 | 8200.12 | 01-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 891.91 | 07-JUL-11:00 | 23805.32 | 11-JUL-08:00 |
August | 0.00 | 23173.88 | 01-AUG-08:09 | 8200.12 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 3543.12 | 04-AUG-18:53 | 28053.08 | 19-AUG-09:00 |
September | 0.00 | 23173.88 | 01-SEP-08:09 | 8200.12 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 828.24 | 14-SEP-14:00 | 29762.15 | 23-SEP-09:00 |
October | 0.00 | 23173.88 | 02-OCT-08:09 | 8200.12 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4796.00 | 25-OCT-11:00 | 52035.16 | 28-OCT-08:00 |
November | 0.00 | 23173.88 | 01-NOV-08:09 | 8200.12 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4456.90 | 26-NOV-14:55 | 66818.76 | 23-NOV-01:51 |
December | 0.00 | 23173.88 | 01-DEC-09:09 | 8200.12 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1371.06 | 17-DEC-12:00 | 100497.34 | 31-DEC-21:51 |
Annual Sum or Average | |||||||||||||
Minimum of Months | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23805.32 | ||||
Maximum of Months | 0.00 | 23173.88 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 22894.25 | 112510.55 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1274.78 | 07-JAN-07:05 | 553.77 | 4231.75 | 3825.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1390.84 |
February | 0.00 | 01-FEB-00:02 | 0.00 | 2267.01 | 2868.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 653.69 |
March | 898.59 | 29-MAR-15:00 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1172.68 |
April | 3130.70 | 07-APR-16:00 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 200.74 | 0.00 |
May | 16313.26 | 31-MAY-05:03 | 290.07 | 2317.39 | 2295.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 391.13 |
June | 18241.25 | 23-JUN-05:01 | 580.14 | 4634.78 | 4590.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 455.54 |
July | 17779.15 | 11-JUL-05:01 | 652.66 | 5214.12 | 5163.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 643.60 |
August | 19857.43 | 25-AUG-05:01 | 580.14 | 4634.78 | 4590.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 643.73 |
September | 19063.81 | 02-SEP-05:01 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 214.64 |
October | 5691.27 | 04-OCT-15:30 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 55.96 |
November | 902.10 | 04-NOV-14:10 | 659.25 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.85 |
December | 1907.21 | 02-DEC-07:05 | 553.77 | 4231.75 | 3825.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1837.71 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 1939.55 | 1912.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 19857.43 | 725.17 | 5793.47 | 5737.50 | 0.00 | 0.00 | 0.00 | 0.00 | 200.74 | 1837.71 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3095.83 | 31-JAN-16:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 3305.87 | 03-FEB-14:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2663.20 |
March | 4294.44 | 18-MAR-10:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 2863.26 | 12-APR-08:15 | 0.00 | 20151.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5737.97 |
May | 20164.81 | 29-MAY-13:30 | 0.00 | 2370.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.49 |
June | 50897.23 | 22-JUN-17:08 | 0.00 | 4741.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2248.94 | 0.00 |
July | 52648.58 | 11-JUL-17:06 | 0.00 | 5926.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 982.40 | 0.00 |
August | 55341.66 | 20-AUG-15:13 | 0.00 | 3556.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 62.86 | 0.00 |
September | 50115.64 | 04-SEP-13:13 | 0.00 | 3556.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 530.22 |
October | 6622.96 | 04-OCT-14:10 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 738.66 |
November | 4155.35 | 20-NOV-07:05 | 0.00 | 28448.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9083.43 |
December | 3036.37 | 09-DEC-11:00 | 0.00 | 10075.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 2863.26 | 0.00 | 2370.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 55341.66 | 0.00 | 28448.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2248.94 | 9083.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum}[W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 0.00 | 01-JAN-00:01 | 0.00 | 27263.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80082.41 |
February | 0.00 | 01-FEB-00:02 | 0.00 | 13631.69 | 10250.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22267.14 |
March | 0.00 | 01-MAR-00:03 | 0.00 | 8179.02 | 6150.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8263.34 |
April | 0.00 | 01-APR-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9753.66 |
May | 0.00 | 01-MAY-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4674.60 |
June | 0.00 | 01-JUN-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7486.94 |
July | 0.00 | 01-JUL-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9526.88 |
August | 0.00 | 01-AUG-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6089.88 |
September | 0.00 | 01-SEP-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7482.78 |
October | 0.00 | 01-OCT-00:10 | 0.00 | 2726.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20634.64 |
November | 0.00 | 01-NOV-00:10 | 0.00 | 2726.34 | 2050.03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13006.74 |
December | 0.00 | 01-DEC-00:03 | 0.00 | 10905.36 | 8200.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15326.18 |
Annual Sum or Average | |||||||||||
Minimum of Months | 0.00 | 0.00 | 2726.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4674.60 | |
Maximum of Months | 0.00 | 0.00 | 27263.39 | 10250.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 80082.41 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | GAS:FACILITY [J] | GAS:FACILITY {Maximum}[W] | GAS:FACILITY {TIMESTAMP} | |
January | 0.725870E+11 | 55340.99 | 11-JAN-16:00 | 0.224388E+12 | 320943.69 | 01-JAN-20:49 |
February | 0.655235E+11 | 51736.65 | 07-FEB-13:30 | 0.214211E+12 | 354750.05 | 06-FEB-00:00 |
March | 0.726880E+11 | 51587.73 | 16-MAR-12:00 | 0.880676E+11 | 232446.41 | 22-MAR-06:00 |
April | 0.664461E+11 | 52357.41 | 07-APR-14:00 | 0.273972E+11 | 77026.14 | 02-APR-05:00 |
May | 0.684328E+11 | 61278.96 | 31-MAY-13:00 | 0.139506E+11 | 28280.84 | 02-MAY-05:10 |
June | 0.729143E+11 | 71862.23 | 19-JUN-12:20 | 0.129600E+11 | 5000.00 | 01-JUN-00:10 |
July | 0.791309E+11 | 71349.30 | 08-JUL-12:09 | 0.133920E+11 | 5000.00 | 01-JUL-00:10 |
August | 0.838832E+11 | 72235.72 | 04-AUG-14:09 | 0.133920E+11 | 5000.00 | 01-AUG-00:10 |
September | 0.710562E+11 | 66841.59 | 14-SEP-13:39 | 0.129600E+11 | 5000.00 | 01-SEP-00:10 |
October | 0.692948E+11 | 56526.65 | 04-OCT-14:20 | 0.142514E+11 | 32410.36 | 31-OCT-06:10 |
November | 0.680558E+11 | 55333.00 | 25-NOV-16:30 | 0.692219E+11 | 218539.51 | 23-NOV-02:09 |
December | 0.723979E+11 | 55339.50 | 30-DEC-16:40 | 0.153030E+12 | 318161.45 | 31-DEC-22:10 |
Annual Sum or Average | 0.862411E+12 | 0.857222E+12 | ||||
Minimum of Months | 0.655235E+11 | 51587.73 | 0.129600E+11 | 5000.00 | ||
Maximum of Months | 0.838832E+11 | 72235.72 | 0.224388E+12 | 354750.05 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [J] | COGENERATION:ELECTRICITY [] | |
January | 0.396181E+11 | 0.127661E+11 | 0.115358E+11 | 0.00 | 0.641109E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.225597E+10 | 0.00 |
February | 0.362526E+11 | 0.107059E+11 | 0.105871E+11 | 0.00 | 0.591839E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.205943E+10 | 0.00 |
March | 0.418523E+11 | 0.107201E+11 | 0.123357E+11 | 0.00 | 0.547306E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.230691E+10 | 0.00 |
April | 0.392410E+11 | 0.923983E+10 | 0.114862E+11 | 0.00 | 0.424456E+10 | 0.00 | 0.00 | 84608817.65 | 0.00 | 0.00 | 0.00 | 0.214995E+10 | 0.00 |
May | 0.407352E+11 | 0.854213E+10 | 0.119357E+11 | 0.00 | 0.415297E+10 | 0.00 | 0.00 | 0.904352E+09 | 0.00 | 0.00 | 0.00 | 0.216241E+10 | 0.00 |
June | 0.403581E+11 | 0.773600E+10 | 0.118862E+11 | 0.00 | 0.444489E+10 | 0.00 | 0.00 | 0.643629E+10 | 0.00 | 0.00 | 0.00 | 0.205287E+10 | 0.00 |
July | 0.396181E+11 | 0.823099E+10 | 0.115358E+11 | 0.00 | 0.527033E+10 | 0.00 | 0.00 | 0.124420E+11 | 0.00 | 0.00 | 0.00 | 0.203366E+10 | 0.00 |
August | 0.418523E+11 | 0.908898E+10 | 0.123357E+11 | 0.00 | 0.581835E+10 | 0.00 | 0.00 | 0.127152E+11 | 0.00 | 0.00 | 0.00 | 0.207271E+10 | 0.00 |
September | 0.392410E+11 | 0.987625E+10 | 0.114862E+11 | 0.00 | 0.415183E+10 | 0.00 | 0.00 | 0.429945E+10 | 0.00 | 0.00 | 0.00 | 0.200152E+10 | 0.00 |
October | 0.396181E+11 | 0.113848E+11 | 0.115358E+11 | 0.00 | 0.399166E+10 | 0.00 | 0.00 | 0.665471E+09 | 0.00 | 0.00 | 0.00 | 0.209894E+10 | 0.00 |
November | 0.381239E+11 | 0.120542E+11 | 0.110862E+11 | 0.00 | 0.470011E+10 | 0.00 | 0.00 | 4369974.09 | 0.00 | 0.00 | 0.00 | 0.208699E+10 | 0.00 |
December | 0.396181E+11 | 0.130159E+11 | 0.115358E+11 | 0.00 | 0.600972E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.221833E+10 | 0.00 |
Annual Sum or Average | 0.476129E+12 | 0.123361E+12 | 0.139282E+12 | 0.605869E+11 | 0.00 | 0.375518E+11 | 0.254997E+11 | ||||||
Minimum of Months | 0.362526E+11 | 0.773600E+10 | 0.105871E+11 | 0.00 | 0.399166E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.200152E+10 | 0.00 |
Maximum of Months | 0.418523E+11 | 0.130159E+11 | 0.123357E+11 | 0.00 | 0.641109E+10 | 0.00 | 0.00 | 0.127152E+11 | 0.00 | 0.00 | 0.00 | 0.230691E+10 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS [J] | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | HUMIDIFIER:GAS [] | |
January | 0.00 | 0.00 | 0.224388E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.214211E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.880676E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.273972E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.139506E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.129600E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.133920E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.133920E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.129600E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.142514E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.692219E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.153030E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.857222E+12 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.129600E+11 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.224388E+12 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum}[W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum}[W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum}[W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {Maximum}[W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {Maximum}[W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 35189.04 | 02-JAN-09:09 | 7857.00 | 01-JAN-00:10 | 10112.62 | 02-JAN-08:09 | 0.00 | 4476.01 | 06-JAN-16:49 | 0.00 | 0.00 | 01-JAN-00:10 |
February | 35189.04 | 01-FEB-09:09 | 7857.00 | 01-FEB-00:10 | 10112.62 | 01-FEB-08:09 | 0.00 | 4476.01 | 03-FEB-07:40 | 0.00 | 0.00 | 01-FEB-00:10 |
March | 35189.04 | 01-MAR-09:09 | 7857.00 | 01-MAR-00:10 | 10112.62 | 01-MAR-08:09 | 0.00 | 4476.01 | 16-MAR-14:39 | 0.00 | 0.00 | 01-MAR-00:10 |
April | 35189.04 | 01-APR-08:09 | 7857.00 | 01-APR-00:10 | 10112.62 | 01-APR-07:10 | 0.00 | 4476.01 | 03-APR-06:10 | 0.00 | 0.00 | 01-APR-00:10 |
May | 35189.04 | 01-MAY-08:09 | 7857.00 | 01-MAY-00:10 | 10112.62 | 01-MAY-07:10 | 0.00 | 4024.33 | 01-MAY-06:10 | 0.00 | 0.00 | 01-MAY-00:10 |
June | 35189.04 | 01-JUN-08:09 | 7857.00 | 01-JUN-00:10 | 10112.62 | 01-JUN-07:10 | 0.00 | 6329.62 | 19-JUN-09:20 | 0.00 | 0.00 | 01-JUN-00:10 |
July | 35189.04 | 01-JUL-08:09 | 7857.00 | 01-JUL-00:10 | 10112.62 | 01-JUL-07:10 | 0.00 | 6329.62 | 21-JUL-11:00 | 0.00 | 0.00 | 01-JUL-00:10 |
August | 35189.04 | 01-AUG-08:09 | 7857.00 | 01-AUG-00:10 | 10112.62 | 01-AUG-07:10 | 0.00 | 6329.62 | 04-AUG-10:50 | 0.00 | 0.00 | 01-AUG-00:10 |
September | 35189.04 | 01-SEP-08:09 | 7857.00 | 01-SEP-00:10 | 10112.62 | 01-SEP-07:10 | 0.00 | 6329.62 | 01-SEP-11:09 | 0.00 | 0.00 | 01-SEP-00:10 |
October | 35189.04 | 02-OCT-08:09 | 7857.00 | 01-OCT-00:10 | 10112.62 | 02-OCT-07:10 | 0.00 | 4024.33 | 05-OCT-11:50 | 0.00 | 0.00 | 01-OCT-00:10 |
November | 35189.04 | 01-NOV-08:09 | 7857.00 | 01-NOV-00:10 | 10112.62 | 01-NOV-07:10 | 0.00 | 4476.01 | 20-NOV-07:10 | 0.00 | 0.00 | 01-NOV-00:10 |
December | 35189.04 | 01-DEC-09:09 | 7857.00 | 01-DEC-00:10 | 10112.62 | 01-DEC-08:09 | 0.00 | 4476.01 | 01-DEC-12:00 | 0.00 | 0.00 | 01-DEC-00:10 |
Annual Sum or Average | ||||||||||||
Minimum of Months | 35189.04 | 7857.00 | 10112.62 | 0.00 | 4024.33 | 0.00 | 0.00 | |||||
Maximum of Months | 35189.04 | 7857.00 | 10112.62 | 0.00 | 6329.62 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum}[W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY {Maximum}[W] | WATERSYSTEMS:ELECTRICITY {TIMESTAMP} | COGENERATION:ELECTRICITY [] | |
January | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 2470.63 | 30-JAN-12:00 | 0.00 |
February | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 2477.26 | 06-FEB-12:50 | 0.00 |
March | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 2444.25 | 01-MAR-12:09 | 0.00 |
April | 1354.02 | 07-APR-15:00 | 0.00 | 0.00 | 0.00 | 2277.12 | 01-APR-11:50 | 0.00 |
May | 10230.98 | 31-MAY-13:00 | 0.00 | 0.00 | 0.00 | 1970.05 | 03-MAY-11:00 | 0.00 |
June | 19661.90 | 19-JUN-11:00 | 0.00 | 0.00 | 0.00 | 1792.54 | 01-JUN-11:09 | 0.00 |
July | 18039.00 | 07-JUL-11:00 | 0.00 | 0.00 | 0.00 | 1771.95 | 01-JUL-11:20 | 0.00 |
August | 18998.36 | 16-AUG-15:39 | 0.00 | 0.00 | 0.00 | 1763.66 | 31-AUG-11:09 | 0.00 |
September | 13975.90 | 07-SEP-13:00 | 0.00 | 0.00 | 0.00 | 1778.08 | 30-SEP-11:09 | 0.00 |
October | 5454.99 | 04-OCT-14:20 | 0.00 | 0.00 | 0.00 | 1803.26 | 31-OCT-11:09 | 0.00 |
November | 326.47 | 04-NOV-13:39 | 0.00 | 0.00 | 0.00 | 2086.10 | 28-NOV-12:00 | 0.00 |
December | 0.00 | 01-DEC-00:10 | 0.00 | 0.00 | 0.00 | 2350.40 | 30-DEC-12:00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 1763.66 | 0.00 | ||
Maximum of Months | 19661.90 | 0.00 | 0.00 | 0.00 | 2477.26 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportELECTRICITY:FACILITY {Maximum}[W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY [] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 55340.99 | 11-JAN-16:00 | 31277.33 | 10112.62 | 7857.00 | 0.00 | 4476.01 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 51736.65 | 07-FEB-13:30 | 35189.04 | 10112.62 | 0.00 | 0.00 | 4476.01 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 51587.73 | 16-MAR-12:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 4476.01 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 52357.41 | 07-APR-14:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 4024.33 | 0.00 | 0.00 | 1235.31 | 0.00 |
May | 61278.96 | 31-MAY-13:00 | 35189.04 | 10112.62 | 0.00 | 0.00 | 4024.33 | 0.00 | 0.00 | 10230.98 | 0.00 |
June | 71862.23 | 19-JUN-12:20 | 35189.04 | 10112.62 | 0.00 | 0.00 | 6329.62 | 0.00 | 0.00 | 18486.14 | 0.00 |
July | 71349.30 | 08-JUL-12:09 | 35189.04 | 10112.62 | 0.00 | 0.00 | 6329.62 | 0.00 | 0.00 | 17982.71 | 0.00 |
August | 72235.72 | 04-AUG-14:09 | 35189.04 | 10112.62 | 0.00 | 0.00 | 6329.62 | 0.00 | 0.00 | 18875.24 | 0.00 |
September | 66841.59 | 14-SEP-13:39 | 35189.04 | 10112.62 | 0.00 | 0.00 | 6329.62 | 0.00 | 0.00 | 13505.77 | 0.00 |
October | 56526.65 | 04-OCT-14:20 | 35189.04 | 10112.62 | 0.00 | 0.00 | 4024.33 | 0.00 | 0.00 | 5454.99 | 0.00 |
November | 55333.00 | 25-NOV-16:30 | 31277.33 | 10112.62 | 7857.00 | 0.00 | 4476.01 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 55339.50 | 30-DEC-16:40 | 31277.33 | 10112.62 | 7857.00 | 0.00 | 4476.01 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||||||
Minimum of Months | 51587.73 | 31277.33 | 10112.62 | 0.00 | 0.00 | 4024.33 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 72235.72 | 35189.04 | 10112.62 | 7857.00 | 0.00 | 6329.62 | 0.00 | 0.00 | 18875.24 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportINTERIOREQUIPMENT:GAS [] | EXTERIOREQUIPMENT:GAS [] | HEATING:GAS {Maximum}[W] | HEATING:GAS {TIMESTAMP} | COOLING:GAS [] | WATERSYSTEMS:GAS [] | COGENERATION:GAS [] | |
January | 0.00 | 0.00 | 320943.69 | 01-JAN-20:49 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 354750.05 | 06-FEB-00:00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 232446.41 | 22-MAR-06:00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 77026.14 | 02-APR-05:00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 28280.84 | 02-MAY-05:10 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 5000.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 5000.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 5000.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 5000.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 32410.36 | 31-OCT-06:10 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 218539.51 | 23-NOV-02:09 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 318161.45 | 31-DEC-22:10 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | |||||||
Minimum of Months | 0.00 | 0.00 | 5000.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 354750.05 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 22.33 | 16.76 | 9.33 | 19.36 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 24.00 | 16.54 | 9.33 | 19.16 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 11.50 | 18.63 | 9.33 | 19.48 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6.00 | 19.72 | 5.67 | 20.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 1.67 | 20.41 | 1.67 | 20.41 | 0.17 | 24.46 | 0.17 | 24.46 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 24.60 | 1.83 | 24.60 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 24.77 | 7.67 | 24.77 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 25.18 | 5.50 | 24.89 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 2.67 | 24.64 | 2.67 | 24.64 |
October | 0.67 | 20.37 | 0.67 | 20.37 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 7.50 | 19.21 | 6.67 | 19.73 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 12.17 | 18.44 | 9.67 | 19.35 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 85.83 | 17.71 | 52.33 | 19.51 | 18.17 | 24.86 | 17.83 | 24.77 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 24.00 | 20.41 | 9.67 | 20.41 | 7.67 | 25.18 | 7.67 | 24.89 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 117.33 | 13.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 107.83 | 13.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 74.17 | 14.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 22.67 | 14.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.17 | 15.00 | 0.00 | 0.00 | 0.17 | 27.27 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.00 | 27.38 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.67 | 27.46 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 | 27.47 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 3.67 | 27.37 | 0.00 | 0.00 |
October | 0.33 | 14.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 63.67 | 14.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 107.33 | 14.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 493.50 | 14.18 | 0.00 | 40.50 | 27.45 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 117.33 | 15.00 | 0.00 | 0.00 | 17.67 | 27.47 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 300.00 | 21.04 | 300.00 | 21.04 | 300.00 | 21.04 |
February | 276.00 | 21.03 | 276.00 | 21.03 | 276.00 | 21.03 |
March | 324.00 | 21.12 | 310.33 | 21.07 | 310.33 | 21.07 |
April | 300.00 | 21.77 | 200.67 | 21.10 | 200.67 | 21.10 |
May | 279.50 | 22.97 | 44.33 | 22.08 | 29.17 | 21.14 |
June | 38.00 | 23.84 | 256.00 | 23.90 | 21.67 | 23.92 |
July | 42.17 | 24.08 | 300.00 | 23.93 | 42.17 | 24.08 |
August | 20.83 | 24.14 | 314.50 | 23.92 | 20.83 | 24.14 |
September | 82.00 | 23.60 | 167.50 | 23.91 | 11.50 | 24.02 |
October | 230.33 | 22.76 | 68.83 | 22.25 | 46.67 | 21.47 |
November | 288.00 | 21.33 | 235.83 | 21.08 | 235.83 | 21.08 |
December | 300.00 | 21.04 | 300.00 | 21.04 | 300.00 | 21.04 |
Annual Sum or Average | 2480.83 | 21.75 | 2774.00 | 22.17 | 1794.83 | 21.23 |
Minimum of Months | 20.83 | 21.03 | 44.33 | 21.03 | 11.50 | 21.03 |
Maximum of Months | 324.00 | 24.14 | 314.50 | 23.93 | 310.33 | 24.14 |
Report: ComfortReportSimple55Monthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: OccupantComfortDataSummaryMonthly
For: OFFICE PEOPLE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV [] | ZONE THERMAL COMFORT FANGER MODEL PPD [] | |
January | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
February | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
March | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
April | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
May | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
June | 312.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
July | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
August | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
September | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
October | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
November | 288.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
December | 300.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Annual Sum or Average | 3636.00000 | 0.00000 | 0.00000 | ||
Minimum of Months | 276.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Maximum of Months | 324.00000 | 0.00000 | 0.00000 | 0.00000 | 0.00000 |
Report: DXReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 |
April | 0.309116E+09 | 84608817.65 | 39.17 | 0.281883E+09 | 27232663.82 | 0.00 | 0.27 | 07-APR-16:00 | 0.00 | 01-APR-00:10 | 4920.23 | 07-APR-16:00 | 4599.35 | 07-APR-16:00 | 594.99 | 10-APR-10:00 | 1354.02 | 07-APR-16:00 | 0.00 | 01-APR-00:10 |
May | 0.200223E+10 | 0.541909E+09 | 167.68 | 0.176166E+10 | 0.240572E+09 | 0.00 | 1.00 | 31-MAY-05:03 | 0.00 | 01-MAY-00:10 | 21527.38 | 31-MAY-05:03 | 17574.11 | 31-MAY-05:03 | 3953.27 | 31-MAY-05:03 | 5069.08 | 31-MAY-05:03 | 0.00 | 01-MAY-00:10 |
June | 0.860340E+10 | 0.227409E+10 | 289.39 | 0.651357E+10 | 0.208983E+10 | 0.00 | 1.00 | 08-JUN-05:02 | 0.00 | 01-JUN-00:10 | 25863.07 | 19-JUN-05:01 | 19341.35 | 23-JUN-05:01 | 12269.79 | 19-JUN-05:05 | 5789.36 | 19-JUN-05:01 | 0.00 | 01-JUN-00:10 |
July | 0.127257E+11 | 0.334477E+10 | 295.92 | 0.900763E+10 | 0.371804E+10 | 0.00 | 1.00 | 01-JUL-05:02 | 0.00 | 01-JUL-00:10 | 26680.05 | 22-JUL-05:01 | 18526.70 | 11-JUL-05:01 | 14170.99 | 22-JUL-05:03 | 5904.88 | 22-JUL-05:01 | 0.00 | 01-JUL-00:10 |
August | 0.128721E+11 | 0.342493E+10 | 318.23 | 0.985256E+10 | 0.301955E+10 | 0.00 | 1.00 | 01-AUG-05:01 | 0.00 | 01-AUG-00:10 | 26716.70 | 04-AUG-05:01 | 20768.43 | 25-AUG-05:01 | 13389.47 | 04-AUG-05:04 | 5891.29 | 04-AUG-05:01 | 0.00 | 01-AUG-00:10 |
September | 0.683906E+10 | 0.179499E+10 | 265.78 | 0.544110E+10 | 0.139796E+10 | 0.00 | 1.00 | 01-SEP-05:01 | 0.00 | 01-SEP-00:10 | 25600.75 | 14-SEP-05:01 | 20107.27 | 02-SEP-05:01 | 12275.95 | 14-SEP-05:05 | 5746.12 | 14-SEP-05:01 | 0.00 | 01-SEP-00:10 |
October | 0.215119E+10 | 0.571800E+09 | 154.06 | 0.165724E+10 | 0.493953E+09 | 0.00 | 0.45 | 04-OCT-15:30 | 0.00 | 01-OCT-00:10 | 8815.47 | 04-OCT-15:30 | 6895.52 | 04-OCT-15:10 | 2859.64 | 06-OCT-05:05 | 2275.45 | 04-OCT-15:30 | 0.00 | 01-OCT-00:10 |
November | 15812839.14 | 4369974.09 | 5.67 | 14646954.44 | 1165884.70 | 0.00 | 0.07 | 04-NOV-13:40 | 0.00 | 01-NOV-00:10 | 1183.83 | 04-NOV-13:40 | 1091.10 | 04-NOV-13:30 | 118.20 | 04-NOV-15:00 | 326.47 | 04-NOV-13:40 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.455186E+11 | 0.120415E+11 | 1535.89 | 0.345303E+11 | 0.109883E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.128721E+11 | 0.342493E+10 | 318.23 | 0.985256E+10 | 0.371804E+10 | 0.00 | 1.00 | 0.00 | 26716.70 | 20768.43 | 14170.99 | 5904.88 | 0.00 |
Report: DXReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRIC ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRIC ENERGY [J] | COOLING COIL RUNTIME FRACTION {Maximum}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM}[] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum}[W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum}[W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRIC POWER {Maximum}[W] | COOLING COIL ELECTRIC POWER {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {Maximum}[W] | COOLING COIL CRANKCASE HEATER ELECTRIC POWER {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 | 0.00 | 01-JAN-00:01 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 | 0.00 | 01-FEB-00:02 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 | 0.00 | 01-MAR-00:03 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 | 0.00 | 01-APR-00:10 |
May | 0.123014E+10 | 0.362443E+09 | 24.83 | 0.103337E+10 | 0.196764E+09 | 0.00 | 0.47 | 29-MAY-12:05 | 0.00 | 01-MAY-00:10 | 25874.50 | 31-MAY-14:00 | 22166.54 | 29-MAY-13:30 | 5863.01 | 31-MAY-13:50 | 7654.90 | 29-MAY-12:05 | 0.00 | 01-MAY-00:10 |
June | 0.144802E+11 | 0.416220E+10 | 235.36 | 0.105487E+11 | 0.393151E+10 | 0.00 | 1.00 | 19-JUN-17:06 | 0.00 | 01-JUN-00:10 | 73809.91 | 25-JUN-12:13 | 56528.70 | 22-JUN-17:08 | 32245.72 | 25-JUN-12:13 | 18789.22 | 19-JUN-17:06 | 0.00 | 01-JUN-00:10 |
July | 0.319826E+11 | 0.909725E+10 | 350.87 | 0.216305E+11 | 0.103521E+11 | 0.00 | 1.00 | 02-JUL-12:33 | 0.00 | 01-JUL-00:10 | 74237.42 | 30-JUL-11:33 | 57384.75 | 11-JUL-17:06 | 32856.61 | 09-JUL-09:13 | 18890.81 | 09-JUL-13:13 | 0.00 | 01-JUL-00:10 |
August | 0.322474E+11 | 0.929029E+10 | 352.50 | 0.236787E+11 | 0.856875E+10 | 0.00 | 1.00 | 01-AUG-17:06 | 0.00 | 01-AUG-00:10 | 76723.64 | 03-AUG-05:01 | 60151.91 | 20-AUG-15:13 | 38303.39 | 03-AUG-05:01 | 18944.51 | 04-AUG-19:43 | 0.00 | 01-AUG-00:10 |
September | 0.878013E+10 | 0.250446E+10 | 175.49 | 0.674351E+10 | 0.203662E+10 | 0.00 | 1.00 | 04-SEP-11:53 | 0.00 | 01-SEP-00:10 | 66205.66 | 07-SEP-17:10 | 54103.75 | 04-SEP-13:13 | 25222.44 | 07-SEP-17:10 | 16801.01 | 04-SEP-11:53 | 0.00 | 01-SEP-00:10 |
October | 0.329360E+09 | 93670741.67 | 13.00 | 0.231635E+09 | 97724820.65 | 0.00 | 0.20 | 04-OCT-14:00 | 0.00 | 01-OCT-00:10 | 11640.73 | 04-OCT-14:00 | 8565.40 | 04-OCT-14:00 | 3205.68 | 05-OCT-13:50 | 3309.57 | 04-OCT-14:00 | 0.00 | 01-OCT-00:10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 | 0.00 | 01-NOV-00:10 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 | 0.00 | 01-DEC-00:03 |
Annual Sum or Average | 0.890498E+11 | 0.255103E+11 | 1152.05 | 0.638664E+11 | 0.251834E+11 | 0.00 | ||||||||||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Maximum of Months | 0.322474E+11 | 0.929029E+10 | 352.50 | 0.236787E+11 | 0.103521E+11 | 0.00 | 1.00 | 0.00 | 76723.64 | 60151.91 | 38303.39 | 18944.51 | 0.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.61 | 27.37 | 39.24 | 30.91 | 168.59 | 0.00 | 0.00 | 744.00 |
February | 97.63 | 42.83 | 54.80 | 53.25 | 172.31 | 0.00 | 0.00 | 672.00 |
March | 145.28 | 67.36 | 77.92 | 115.09 | 102.94 | 0.00 | 0.00 | 744.00 |
April | 157.61 | 67.29 | 90.32 | 144.66 | 72.79 | 0.00 | 0.00 | 720.00 |
May | 184.18 | 69.97 | 114.21 | 186.90 | 50.63 | 0.00 | 0.00 | 744.00 |
June | 201.57 | 81.47 | 120.10 | 222.44 | 39.43 | 0.00 | 0.00 | 720.00 |
July | 188.55 | 70.99 | 117.55 | 223.81 | 27.27 | 0.00 | 0.00 | 744.00 |
August | 208.47 | 96.43 | 112.04 | 250.21 | 36.02 | 0.00 | 0.00 | 744.00 |
September | 148.32 | 64.80 | 83.51 | 153.35 | 58.00 | 0.00 | 0.00 | 720.00 |
October | 146.50 | 71.12 | 75.38 | 138.79 | 82.91 | 0.00 | 0.00 | 744.00 |
November | 69.10 | 20.05 | 49.05 | 37.18 | 112.12 | 0.00 | 0.00 | 720.00 |
December | 61.37 | 26.59 | 34.78 | 29.76 | 151.55 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 139.89 | 58.99 | 80.90 | 132.77 | 89.07 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 61.37 | 20.05 | 34.78 | 29.76 | 27.27 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 208.47 | 96.43 | 120.10 | 250.21 | 172.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 66.61 | 27.37 | 39.24 | 30.91 | 168.59 | 0.00 | 0.00 | 744.00 |
February | 97.63 | 42.83 | 54.80 | 53.25 | 172.31 | 0.00 | 0.00 | 672.00 |
March | 145.28 | 67.36 | 77.92 | 115.09 | 102.94 | 0.00 | 0.00 | 744.00 |
April | 157.61 | 67.29 | 90.32 | 144.66 | 72.79 | 0.00 | 0.00 | 720.00 |
May | 184.18 | 69.97 | 114.21 | 186.90 | 50.63 | 0.00 | 0.00 | 744.00 |
June | 201.57 | 81.47 | 120.10 | 222.44 | 39.43 | 0.00 | 0.00 | 720.00 |
July | 188.55 | 70.99 | 117.55 | 223.81 | 27.27 | 0.00 | 0.00 | 744.00 |
August | 208.47 | 96.43 | 112.04 | 250.21 | 36.02 | 0.00 | 0.00 | 744.00 |
September | 148.32 | 64.80 | 83.51 | 153.35 | 58.00 | 0.00 | 0.00 | 720.00 |
October | 146.50 | 71.12 | 75.38 | 138.79 | 82.91 | 0.00 | 0.00 | 744.00 |
November | 69.10 | 20.05 | 49.05 | 37.18 | 112.12 | 0.00 | 0.00 | 720.00 |
December | 61.37 | 26.59 | 34.78 | 29.76 | 151.55 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 139.89 | 58.99 | 80.90 | 132.77 | 89.07 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 61.37 | 20.05 | 34.78 | 29.76 | 27.27 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 208.47 | 96.43 | 120.10 | 250.21 | 172.31 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.76 | 0.00 | 18.76 | 0.37 | 105.43 | 0.00 | 0.00 | 744.00 |
February | 25.68 | 0.00 | 25.68 | 1.52 | 109.80 | 0.00 | 0.00 | 672.00 |
March | 35.62 | 0.00 | 35.62 | 9.86 | 65.02 | 0.00 | 0.00 | 744.00 |
April | 42.80 | 0.14 | 42.66 | 23.69 | 43.84 | 0.00 | 0.00 | 720.00 |
May | 56.97 | 2.06 | 54.91 | 42.70 | 29.05 | 0.00 | 0.00 | 744.00 |
June | 60.07 | 3.12 | 56.95 | 54.85 | 22.11 | 0.00 | 0.00 | 720.00 |
July | 58.29 | 2.20 | 56.08 | 63.37 | 15.53 | 0.00 | 0.00 | 744.00 |
August | 51.62 | 0.70 | 50.92 | 56.07 | 20.93 | 0.00 | 0.00 | 744.00 |
September | 38.86 | 0.02 | 38.85 | 29.99 | 34.81 | 0.00 | 0.00 | 720.00 |
October | 33.61 | 0.00 | 33.61 | 18.25 | 50.12 | 0.00 | 0.00 | 744.00 |
November | 23.58 | 0.00 | 23.58 | 5.05 | 68.78 | 0.00 | 0.00 | 720.00 |
December | 16.37 | 0.00 | 16.37 | 0.42 | 94.87 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 38.59 | 0.69 | 37.90 | 25.68 | 54.71 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 16.37 | 0.00 | 16.37 | 0.37 | 15.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.07 | 3.12 | 56.95 | 63.37 | 109.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 18.76 | 0.00 | 18.76 | 0.37 | 105.43 | 0.00 | 0.00 | 744.00 |
February | 25.68 | 0.00 | 25.68 | 1.52 | 109.80 | 0.00 | 0.00 | 672.00 |
March | 35.62 | 0.00 | 35.62 | 9.86 | 65.02 | 0.00 | 0.00 | 744.00 |
April | 42.80 | 0.14 | 42.66 | 23.69 | 43.84 | 0.00 | 0.00 | 720.00 |
May | 56.97 | 2.06 | 54.91 | 42.70 | 29.05 | 0.00 | 0.00 | 744.00 |
June | 60.07 | 3.12 | 56.94 | 54.85 | 22.11 | 0.00 | 0.00 | 720.00 |
July | 58.28 | 2.20 | 56.08 | 63.37 | 15.53 | 0.00 | 0.00 | 744.00 |
August | 51.62 | 0.70 | 50.92 | 56.07 | 20.93 | 0.00 | 0.00 | 744.00 |
September | 38.86 | 0.02 | 38.85 | 29.99 | 34.80 | 0.00 | 0.00 | 720.00 |
October | 33.61 | 0.00 | 33.61 | 18.25 | 50.12 | 0.00 | 0.00 | 744.00 |
November | 23.58 | 0.00 | 23.58 | 5.05 | 68.78 | 0.00 | 0.00 | 720.00 |
December | 16.37 | 0.00 | 16.37 | 0.42 | 94.87 | 0.00 | 0.00 | 744.00 |
Annual Sum or Average | 38.59 | 0.69 | 37.90 | 25.68 | 54.71 | 0.00 | 0.00 | 8760.00 |
Minimum of Months | 16.37 | 0.00 | 16.37 | 0.37 | 15.53 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 60.07 | 3.12 | 56.94 | 63.37 | 109.80 | 0.00 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 22.91 | 8.87 | 14.04 | 11.95 | 39.55 | 23.50 | 0.00 | 744.00 |
February | 37.95 | 20.08 | 17.87 | 26.01 | 41.63 | 0.00 | 0.00 | 672.00 |
March | 58.18 | 32.22 | 25.96 | 57.03 | 22.96 | 0.33 | 0.00 | 744.00 |
April | 72.54 | 41.11 | 31.43 | 77.29 | 19.76 | 12.33 | 0.00 | 720.00 |
May | 91.95 | 50.38 | 41.57 | 102.87 | 17.41 | 5.17 | 0.00 | 744.00 |
June | 100.78 | 58.04 | 42.74 | 111.93 | 18.54 | 0.00 | 0.00 | 720.00 |
July | 97.11 | 53.58 | 43.53 | 109.30 | 17.05 | 0.00 | 0.00 | 744.00 |
August | 99.46 | 63.12 | 36.34 | 110.29 | 22.83 | 0.00 | 0.00 | 744.00 |
September | 67.71 | 39.70 | 28.01 | 68.19 | 26.56 | 0.00 | 0.00 | 720.00 |
October | 55.40 | 32.08 | 23.33 | 51.88 | 29.81 | 20.50 | 0.00 | 744.00 |
November | 29.55 | 11.21 | 18.35 | 21.27 | 29.40 | 14.50 | 0.00 | 720.00 |
December | 20.03 | 8.53 | 11.50 | 9.02 | 34.79 | 2.33 | 0.00 | 744.00 |
Annual Sum or Average | 62.95 | 35.00 | 27.94 | 63.32 | 26.60 | 78.67 | 0.00 | 8760.00 |
Minimum of Months | 20.03 | 8.53 | 11.50 | 9.02 | 17.05 | 0.00 | 0.00 | 672.00 |
Maximum of Months | 100.78 | 63.12 | 43.53 | 111.93 | 41.63 | 23.50 | 0.00 | 744.00 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW 1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178418E+09 | 73308484.09 | 0.105110E+09 | 82798271.54 | 0.451560E+09 |
February | 0.236178E+09 | 0.103613E+09 | 0.132565E+09 | 0.128812E+09 | 0.416864E+09 |
March | 0.389106E+09 | 0.180404E+09 | 0.208702E+09 | 0.308258E+09 | 0.275708E+09 |
April | 0.408518E+09 | 0.174412E+09 | 0.234106E+09 | 0.374967E+09 | 0.188660E+09 |
May | 0.493311E+09 | 0.187406E+09 | 0.305905E+09 | 0.500605E+09 | 0.135615E+09 |
June | 0.522467E+09 | 0.211167E+09 | 0.311300E+09 | 0.576577E+09 | 0.102191E+09 |
July | 0.505007E+09 | 0.190147E+09 | 0.314859E+09 | 0.599456E+09 | 73028982.35 |
August | 0.558379E+09 | 0.258280E+09 | 0.300099E+09 | 0.670166E+09 | 96487651.00 |
September | 0.384442E+09 | 0.167972E+09 | 0.216469E+09 | 0.397482E+09 | 0.150328E+09 |
October | 0.392388E+09 | 0.190482E+09 | 0.201906E+09 | 0.371726E+09 | 0.222054E+09 |
November | 0.179108E+09 | 51967625.15 | 0.127141E+09 | 96373726.10 | 0.290612E+09 |
December | 0.164375E+09 | 71221879.01 | 93152951.82 | 79701064.00 | 0.405913E+09 |
Annual Sum or Average | 0.441170E+10 | 0.186038E+10 | 0.255131E+10 | 0.418692E+10 | 0.280902E+10 |
Minimum of Months | 0.164375E+09 | 51967625.15 | 93152951.82 | 79701064.00 | 73028982.35 |
Maximum of Months | 0.558379E+09 | 0.258280E+09 | 0.314859E+09 | 0.670166E+09 | 0.451560E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE FRONT WALL WINDOW2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.178418E+09 | 73308484.09 | 0.105110E+09 | 82798271.54 | 0.451560E+09 |
February | 0.236178E+09 | 0.103613E+09 | 0.132565E+09 | 0.128812E+09 | 0.416864E+09 |
March | 0.389106E+09 | 0.180404E+09 | 0.208702E+09 | 0.308258E+09 | 0.275708E+09 |
April | 0.408518E+09 | 0.174412E+09 | 0.234106E+09 | 0.374967E+09 | 0.188660E+09 |
May | 0.493311E+09 | 0.187406E+09 | 0.305905E+09 | 0.500605E+09 | 0.135615E+09 |
June | 0.522467E+09 | 0.211167E+09 | 0.311300E+09 | 0.576577E+09 | 0.102191E+09 |
July | 0.505007E+09 | 0.190147E+09 | 0.314859E+09 | 0.599456E+09 | 73028982.35 |
August | 0.558379E+09 | 0.258280E+09 | 0.300099E+09 | 0.670166E+09 | 96487651.00 |
September | 0.384442E+09 | 0.167972E+09 | 0.216469E+09 | 0.397482E+09 | 0.150328E+09 |
October | 0.392388E+09 | 0.190482E+09 | 0.201906E+09 | 0.371726E+09 | 0.222054E+09 |
November | 0.179108E+09 | 51967625.15 | 0.127141E+09 | 96373726.10 | 0.290612E+09 |
December | 0.164375E+09 | 71221879.01 | 93152951.82 | 79701064.00 | 0.405913E+09 |
Annual Sum or Average | 0.441170E+10 | 0.186038E+10 | 0.255131E+10 | 0.418692E+10 | 0.280902E+10 |
Minimum of Months | 0.164375E+09 | 51967625.15 | 93152951.82 | 79701064.00 | 73028982.35 |
Maximum of Months | 0.558379E+09 | 0.258280E+09 | 0.314859E+09 | 0.670166E+09 | 0.451560E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 50259931.64 | 0.00 | 50259931.64 | 1000522.74 | 0.282372E+09 |
February | 62122661.82 | 0.00 | 62122661.82 | 3682999.01 | 0.265619E+09 |
March | 95408554.48 | 5219.70 | 95403334.78 | 26406994.98 | 0.174161E+09 |
April | 0.110929E+09 | 360036.37 | 0.110569E+09 | 61397440.51 | 0.113629E+09 |
May | 0.152584E+09 | 5506151.45 | 0.147077E+09 | 0.114366E+09 | 77800224.51 |
June | 0.155696E+09 | 8094098.49 | 0.147602E+09 | 0.142167E+09 | 57301133.45 |
July | 0.156111E+09 | 5902475.21 | 0.150209E+09 | 0.169730E+09 | 41585177.75 |
August | 0.138254E+09 | 1863692.65 | 0.136390E+09 | 0.150181E+09 | 56062147.37 |
September | 0.100735E+09 | 45625.88 | 0.100690E+09 | 77735548.34 | 90214582.93 |
October | 90030929.43 | 0.00 | 90030929.43 | 48884399.48 | 0.134246E+09 |
November | 61110922.58 | 0.00 | 61110922.58 | 13100823.95 | 0.178281E+09 |
December | 43840031.46 | 0.00 | 43840031.46 | 1137628.85 | 0.254095E+09 |
Annual Sum or Average | 0.121708E+10 | 21777299.75 | 0.119530E+10 | 0.809791E+09 | 0.172537E+10 |
Minimum of Months | 43840031.46 | 0.00 | 43840031.46 | 1000522.74 | 41585177.75 |
Maximum of Months | 0.156111E+09 | 8094098.49 | 0.150209E+09 | 0.169730E+09 | 0.282372E+09 |
Report: WindowEnergyReportMonthly
For: OFFICE LEFT WALL WINDOW2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 50258286.71 | 0.00 | 50258286.71 | 1000272.09 | 0.282372E+09 |
February | 62120762.55 | 0.00 | 62120762.55 | 3682630.13 | 0.265619E+09 |
March | 95405667.84 | 5219.45 | 95400448.38 | 26405253.16 | 0.174162E+09 |
April | 0.110926E+09 | 360019.50 | 0.110566E+09 | 61394765.83 | 0.113628E+09 |
May | 0.152579E+09 | 5505893.37 | 0.147073E+09 | 0.114362E+09 | 77799930.79 |
June | 0.155691E+09 | 8093719.11 | 0.147597E+09 | 0.142162E+09 | 57300705.00 |
July | 0.156107E+09 | 5902198.55 | 0.150204E+09 | 0.169725E+09 | 41584658.79 |
August | 0.138250E+09 | 1863605.30 | 0.136387E+09 | 0.150178E+09 | 56061396.05 |
September | 0.100732E+09 | 45623.74 | 0.100687E+09 | 77732856.63 | 90213956.64 |
October | 90028275.96 | 0.00 | 90028275.96 | 48882262.22 | 0.134245E+09 |
November | 61108919.30 | 0.00 | 61108919.30 | 13099805.51 | 0.178281E+09 |
December | 43838626.34 | 0.00 | 43838626.34 | 1137463.96 | 0.254095E+09 |
Annual Sum or Average | 0.121705E+10 | 21776279.02 | 0.119527E+10 | 0.809762E+09 | 0.172536E+10 |
Minimum of Months | 43838626.34 | 0.00 | 43838626.34 | 1000272.09 | 41584658.79 |
Maximum of Months | 0.156107E+09 | 8093719.11 | 0.150204E+09 | 0.169725E+09 | 0.282372E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R1C5
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C1
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C2
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C3
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C4
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowEnergyReportMonthly
For: SKYLIGHT_R2C5
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 61367078.16 | 23769717.89 | 37597360.27 | 31999057.91 | 0.105918E+09 |
February | 91811346.76 | 48589389.57 | 43221957.19 | 62913632.03 | 0.100711E+09 |
March | 0.155818E+09 | 86299540.20 | 69518268.93 | 0.152760E+09 | 61508464.17 |
April | 0.188024E+09 | 0.106561E+09 | 81462358.36 | 0.200348E+09 | 51215996.68 |
May | 0.246272E+09 | 0.134944E+09 | 0.111329E+09 | 0.275534E+09 | 46634032.98 |
June | 0.261223E+09 | 0.150449E+09 | 0.110774E+09 | 0.290135E+09 | 48054940.57 |
July | 0.260106E+09 | 0.143510E+09 | 0.116596E+09 | 0.292759E+09 | 45669288.64 |
August | 0.266402E+09 | 0.169057E+09 | 97344867.45 | 0.295413E+09 | 61160088.30 |
September | 0.175506E+09 | 0.102902E+09 | 72604105.51 | 0.176750E+09 | 68843209.91 |
October | 0.148392E+09 | 85916697.53 | 62475191.95 | 0.138958E+09 | 79836230.48 |
November | 76597658.44 | 29046940.18 | 47550718.26 | 55119003.30 | 76214146.73 |
December | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 93174103.30 |
Annual Sum or Average | 0.198515E+10 | 0.110389E+10 | 0.881269E+09 | 0.199684E+10 | 0.838939E+09 |
Minimum of Months | 53635535.40 | 22839895.95 | 30795639.46 | 24152868.28 | 45669288.64 |
Maximum of Months | 0.266402E+09 | 0.169057E+09 | 0.116596E+09 | 0.295413E+09 | 0.105918E+09 |
Report: WindowZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 52.98 | 538.45 | 170.76 | 54.74 | 116.02 | 0.00 | 0.00 |
February | 96.92 | 551.60 | 246.61 | 85.66 | 160.95 | 0.00 | 0.00 |
March | 241.85 | 327.88 | 361.79 | 134.71 | 227.08 | 0.00 | 0.00 |
April | 334.33 | 230.87 | 400.81 | 134.86 | 265.95 | 0.00 | 0.00 |
May | 457.77 | 157.92 | 482.30 | 144.05 | 338.25 | 0.00 | 0.00 |
June | 553.78 | 122.26 | 523.27 | 169.18 | 354.09 | 0.00 | 0.00 |
July | 573.80 | 85.02 | 493.66 | 146.39 | 347.27 | 0.00 | 0.00 |
August | 612.13 | 113.48 | 520.18 | 194.25 | 325.93 | 0.00 | 0.00 |
September | 365.18 | 184.10 | 374.36 | 129.64 | 244.72 | 0.00 | 0.00 |
October | 310.59 | 262.57 | 360.23 | 142.24 | 217.99 | 0.00 | 0.00 |
November | 79.70 | 357.03 | 185.35 | 40.10 | 145.26 | 0.00 | 0.00 |
December | 51.28 | 483.75 | 155.48 | 53.18 | 102.29 | 0.00 | 0.00 |
Annual Sum or Average | 312.37 | 283.05 | 356.97 | 119.37 | 237.61 | 0.00 | 0.00 |
Minimum of Months | 51.28 | 85.02 | 155.48 | 40.10 | 102.29 | 0.00 | 0.00 |
Maximum of Months | 612.13 | 551.60 | 523.27 | 194.25 | 354.09 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 119.47 | 395.45 | 229.12 | 88.75 | 140.37 | 0.00 | 0.00 |
February | 260.06 | 416.30 | 379.51 | 200.85 | 178.66 | 0.00 | 0.00 |
March | 570.34 | 229.65 | 581.76 | 322.21 | 259.55 | 0.00 | 0.00 |
April | 772.95 | 197.59 | 725.40 | 411.12 | 314.28 | 0.00 | 0.00 |
May | 1028.72 | 174.11 | 919.48 | 503.82 | 415.65 | 0.00 | 0.00 |
June | 1119.35 | 185.40 | 1007.80 | 580.44 | 427.37 | 0.00 | 0.00 |
July | 1093.04 | 170.51 | 971.12 | 535.80 | 435.32 | 0.00 | 0.00 |
August | 1102.95 | 228.35 | 994.63 | 631.19 | 363.44 | 0.00 | 0.00 |
September | 681.90 | 265.60 | 677.11 | 397.00 | 280.11 | 0.00 | 0.00 |
October | 518.81 | 298.07 | 554.03 | 320.78 | 233.26 | 0.00 | 0.00 |
November | 212.65 | 294.04 | 295.52 | 112.06 | 183.45 | 0.00 | 0.00 |
December | 90.18 | 347.87 | 200.25 | 85.27 | 114.98 | 0.00 | 0.00 |
Annual Sum or Average | 633.19 | 266.03 | 629.49 | 350.04 | 279.45 | 0.00 | 0.00 |
Minimum of Months | 90.18 | 170.51 | 200.25 | 85.27 | 114.98 | 0.00 | 0.00 |
Maximum of Months | 1119.35 | 416.30 | 1007.80 | 631.19 | 435.32 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.141915E+09 | 0.144218E+10 | 0.457355E+09 | 0.146617E+09 | 0.310738E+09 | 0.00 | 0.00 |
February | 0.234461E+09 | 0.133444E+10 | 0.596599E+09 | 0.207226E+09 | 0.389373E+09 | 0.00 | 0.00 |
March | 0.647784E+09 | 0.878194E+09 | 0.969026E+09 | 0.360819E+09 | 0.608207E+09 | 0.00 | 0.00 |
April | 0.866572E+09 | 0.598423E+09 | 0.103889E+10 | 0.349545E+09 | 0.689346E+09 | 0.00 | 0.00 |
May | 0.122608E+10 | 0.422969E+09 | 0.129179E+10 | 0.385824E+09 | 0.905961E+09 | 0.00 | 0.00 |
June | 0.143540E+10 | 0.316898E+09 | 0.135632E+10 | 0.438523E+09 | 0.917799E+09 | 0.00 | 0.00 |
July | 0.153687E+10 | 0.227729E+09 | 0.132223E+10 | 0.392099E+09 | 0.930132E+09 | 0.00 | 0.00 |
August | 0.163953E+10 | 0.303933E+09 | 0.139326E+10 | 0.520288E+09 | 0.872974E+09 | 0.00 | 0.00 |
September | 0.946547E+09 | 0.477199E+09 | 0.970351E+09 | 0.336036E+09 | 0.634315E+09 | 0.00 | 0.00 |
October | 0.831898E+09 | 0.703278E+09 | 0.964835E+09 | 0.380964E+09 | 0.583871E+09 | 0.00 | 0.00 |
November | 0.206591E+09 | 0.925428E+09 | 0.480437E+09 | 0.103935E+09 | 0.376501E+09 | 0.00 | 0.00 |
December | 0.137337E+09 | 0.129568E+10 | 0.416428E+09 | 0.142444E+09 | 0.273985E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.985097E+10 | 0.892634E+10 | 0.112575E+11 | 0.376432E+10 | 0.749320E+10 | 0.00 | 0.00 |
Minimum of Months | 0.137337E+09 | 0.227729E+09 | 0.416428E+09 | 0.103935E+09 | 0.273985E+09 | 0.00 | 0.00 |
Maximum of Months | 0.163953E+10 | 0.144218E+10 | 0.139326E+10 | 0.520288E+09 | 0.930132E+09 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.319990E+09 | 0.105918E+10 | 0.613671E+09 | 0.237697E+09 | 0.375974E+09 | 0.00 | 0.00 |
February | 0.629135E+09 | 0.100711E+10 | 0.918113E+09 | 0.485894E+09 | 0.432220E+09 | 0.00 | 0.00 |
March | 0.152760E+10 | 0.615084E+09 | 0.155818E+10 | 0.862995E+09 | 0.695183E+09 | 0.00 | 0.00 |
April | 0.200348E+10 | 0.512160E+09 | 0.188024E+10 | 0.106561E+10 | 0.814624E+09 | 0.00 | 0.00 |
May | 0.275534E+10 | 0.466340E+09 | 0.246272E+10 | 0.134944E+10 | 0.111329E+10 | 0.00 | 0.00 |
June | 0.290135E+10 | 0.480549E+09 | 0.261223E+10 | 0.150449E+10 | 0.110774E+10 | 0.00 | 0.00 |
July | 0.292759E+10 | 0.456693E+09 | 0.260106E+10 | 0.143510E+10 | 0.116596E+10 | 0.00 | 0.00 |
August | 0.295413E+10 | 0.611600E+09 | 0.266402E+10 | 0.169057E+10 | 0.973449E+09 | 0.00 | 0.00 |
September | 0.176749E+10 | 0.688430E+09 | 0.175506E+10 | 0.102902E+10 | 0.726041E+09 | 0.00 | 0.00 |
October | 0.138958E+10 | 0.798362E+09 | 0.148392E+10 | 0.859167E+09 | 0.624752E+09 | 0.00 | 0.00 |
November | 0.551190E+09 | 0.762141E+09 | 0.765977E+09 | 0.290469E+09 | 0.475507E+09 | 0.00 | 0.00 |
December | 0.241529E+09 | 0.931741E+09 | 0.536355E+09 | 0.228399E+09 | 0.307956E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.199684E+11 | 0.838939E+10 | 0.198515E+11 | 0.110389E+11 | 0.881269E+10 | 0.00 | 0.00 |
Minimum of Months | 0.241529E+09 | 0.456693E+09 | 0.536355E+09 | 0.228399E+09 | 0.307956E+09 | 0.00 | 0.00 |
Maximum of Months | 0.295413E+10 | 0.105918E+10 | 0.266402E+10 | 0.169057E+10 | 0.116596E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 1.17 | -0.6 | -4.4 | 5.65 | -10.4 | 36.91 | 88.07 | 0.05 |
February | -0.2 | -2.5 | -7.5 | 5.07 | -13.4 | 46.98 | 136.68 | 0.04 |
March | 5.59 | 3.46 | 0.29 | 5.58 | -4.1 | 68.24 | 153.73 | 0.03 |
April | 10.94 | 7.99 | 4.75 | 4.99 | 0.53 | 82.64 | 161.98 | 0.05 |
May | 16.05 | 12.30 | 9.14 | 4.42 | 7.76 | 109.28 | 173.60 | 0.03 |
June | 21.71 | 18.07 | 15.84 | 4.92 | 13.23 | 112.36 | 186.51 | 0.01 |
July | 25.05 | 21.75 | 20.26 | 4.06 | 17.38 | 114.46 | 172.96 | 0.02 |
August | 24.79 | 19.83 | 17.14 | 4.19 | 14.42 | 95.56 | 226.16 | 0.00 |
September | 19.96 | 15.95 | 13.24 | 3.91 | 10.59 | 73.65 | 166.08 | 0.03 |
October | 14.02 | 11.02 | 7.95 | 4.86 | 2.63 | 61.34 | 179.75 | 0.00 |
November | 7.31 | 5.00 | 2.14 | 5.60 | -4.0 | 48.23 | 90.71 | 0.03 |
December | 3.33 | 0.97 | -2.8 | 5.64 | -8.5 | 30.23 | 98.59 | 0.04 |
Annual Sum or Average | 12.55 | 9.51 | 6.43 | 4.91 | 2.28 | 73.48 | 153.05 | 0.03 |
Minimum of Months | -0.2 | -2.5 | -7.5 | 3.91 | -13.4 | 30.23 | 88.07 | 0.00 |
Maximum of Months | 25.05 | 21.75 | 20.26 | 5.65 | 17.38 | 114.46 | 226.16 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 12.20 | 24-JAN-12:20 | 11.81 | 11.50 | 1.00 | 8.15 | 93.67 | 0.00 |
February | 10.00 | 20-FEB-11:00 | 4.34 | -3.3 | 2.60 | -3.9 | 151.50 | 540.00 |
March | 22.20 | 27-MAR-15:00 | 16.33 | 12.80 | 6.70 | 11.65 | 136.50 | 590.00 |
April | 26.70 | 07-APR-12:00 | 16.37 | 9.40 | 6.20 | 11.65 | 179.00 | 713.50 |
May | 30.00 | 30-MAY-12:00 | 17.98 | 10.60 | 5.20 | 17.39 | 233.50 | 730.00 |
June | 36.70 | 19-JUN-11:00 | 24.26 | 19.40 | 5.20 | 24.83 | 185.00 | 771.50 |
July | 33.90 | 07-JUL-11:00 | 23.29 | 18.90 | 3.60 | 23.82 | 331.00 | 570.00 |
August | 33.90 | 24-AUG-14:00 | 20.20 | 12.80 | 8.80 | 21.61 | 240.00 | 432.00 |
September | 31.10 | 01-SEP-13:00 | 17.31 | 8.30 | 4.60 | 18.46 | 182.00 | 662.00 |
October | 25.00 | 04-OCT-12:00 | 18.52 | 15.00 | 5.20 | 11.27 | 171.50 | 695.00 |
November | 17.80 | 04-NOV-12:20 | 12.56 | 8.50 | 3.60 | 6.14 | 182.50 | 595.67 |
December | 12.20 | 17-DEC-12:20 | 4.63 | -6.1 | 4.27 | -4.7 | 53.17 | 801.67 |
Annual Sum or Average | ||||||||
Minimum of Months | 10.00 | 4.34 | -6.1 | 1.00 | -4.7 | 53.17 | 0.00 | |
Maximum of Months | 36.70 | 24.26 | 19.40 | 8.80 | 24.83 | 331.00 | 801.67 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM}[C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -12.2 | 02-JAN-04:00 | -13.4 | -19.4 | 2.60 | -30.7 | 0.00 | 0.00 |
February | -13.9 | 06-FEB-02:00 | -15.2 | -22.8 | 7.20 | -34.1 | 0.00 | 0.00 |
March | -5.0 | 23-MAR-03:00 | -7.4 | -14.4 | 1.50 | -23.9 | 0.00 | 0.00 |
April | 2.20 | 01-APR-03:00 | 0.56 | -1.7 | 3.10 | -6.6 | 0.00 | 0.00 |
May | 6.10 | 01-MAY-04:00 | 4.33 | 2.20 | 3.60 | -9.7 | 25.50 | 0.00 |
June | 13.30 | 03-JUN-02:00 | 9.34 | 5.60 | 4.60 | -2.1 | 0.00 | 0.00 |
July | 18.30 | 02-JUL-02:00 | 17.54 | 17.20 | 0.00 | 5.33 | 0.00 | 0.00 |
August | 15.00 | 08-AUG-04:00 | 12.46 | 10.60 | 3.10 | 3.06 | 0.00 | 0.00 |
September | 10.00 | 24-SEP-05:00 | 8.56 | 7.20 | 2.60 | -3.4 | 18.50 | 158.50 |
October | 2.20 | 09-OCT-03:00 | 1.71 | 1.10 | 0.00 | -13.7 | 0.00 | 0.00 |
November | -4.4 | 24-NOV-05:00 | -6.1 | -10.0 | 1.50 | -19.7 | 0.00 | 0.00 |
December | -8.3 | 31-DEC-23:00 | -10.4 | -18.9 | 9.30 | -26.2 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -13.9 | -15.2 | -22.8 | 0.00 | -34.1 | 0.00 | 0.00 | |
Maximum of Months | 18.30 | 17.54 | 17.20 | 9.30 | 5.33 | 25.50 | 158.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.93 | 24-JAN-11:00 | 12.20 | 11.70 | 1.50 | 8.15 | 103.00 | 0.00 |
February | 6.67 | 28-FEB-09:00 | 7.20 | 6.10 | 4.10 | 2.01 | 101.50 | 0.00 |
March | 16.98 | 27-MAR-12:00 | 20.60 | 15.00 | 3.60 | 10.50 | 295.50 | 565.50 |
April | 17.69 | 09-APR-10:00 | 21.70 | 15.60 | 4.10 | 14.84 | 244.50 | 281.50 |
May | 20.42 | 31-MAY-12:00 | 26.10 | 17.80 | 4.10 | 17.03 | 214.00 | 772.00 |
June | 24.95 | 15-JUN-11:00 | 31.10 | 22.80 | 5.20 | 22.47 | 380.00 | 460.00 |
July | 26.09 | 08-JUL-11:00 | 32.20 | 23.90 | 5.20 | 22.47 | 354.00 | 501.50 |
August | 25.83 | 03-AUG-13:00 | 30.00 | 24.40 | 6.20 | 20.57 | 298.00 | 500.00 |
September | 23.56 | 07-SEP-13:00 | 27.20 | 22.20 | 6.20 | 15.02 | 148.00 | 730.50 |
October | 19.75 | 25-OCT-10:00 | 25.00 | 17.20 | 7.70 | 14.84 | 189.00 | 308.50 |
November | 16.10 | 10-NOV-07:00 | 16.10 | 16.10 | 8.20 | 12.98 | 71.50 | 0.00 |
December | 10.26 | 25-DEC-08:00 | 10.60 | 10.00 | 3.60 | 6.15 | 43.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.67 | 7.20 | 6.10 | 1.50 | 2.01 | 43.00 | 0.00 | |
Maximum of Months | 26.09 | 32.20 | 24.40 | 8.20 | 22.47 | 380.00 | 772.00 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum}[C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 11.70 | 18-JAN-15:00 | 12.20 | 11.93 | 14.90 | 8.15 | 22.00 | 2.00 |
February | 6.10 | 28-FEB-10:20 | 7.03 | 6.58 | 3.43 | 1.87 | 109.83 | 0.00 |
March | 15.00 | 27-MAR-12:20 | 18.00 | 16.18 | 3.93 | 10.11 | 271.83 | 611.17 |
April | 15.60 | 09-APR-10:00 | 21.70 | 17.69 | 4.10 | 14.84 | 244.50 | 281.50 |
May | 18.00 | 18-MAY-09:00 | 18.00 | 18.00 | 4.60 | 15.39 | 265.50 | 12.00 |
June | 22.80 | 15-JUN-11:00 | 31.10 | 24.95 | 5.20 | 22.47 | 380.00 | 460.00 |
July | 24.40 | 09-JUL-07:00 | 27.20 | 25.16 | 2.10 | 15.39 | 195.00 | 504.00 |
August | 25.00 | 03-AUG-19:00 | 26.10 | 25.32 | 5.70 | 19.35 | 0.00 | 0.00 |
September | 22.20 | 07-SEP-13:00 | 27.20 | 23.56 | 6.20 | 15.02 | 148.00 | 730.50 |
October | 18.30 | 05-OCT-18:00 | 19.40 | 18.62 | 7.70 | 6.55 | 0.00 | 0.00 |
November | 16.10 | 10-NOV-07:00 | 16.10 | 16.10 | 8.20 | 12.98 | 71.50 | 0.00 |
December | 10.00 | 25-DEC-08:00 | 10.60 | 10.26 | 3.60 | 6.15 | 43.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 6.10 | 7.03 | 6.58 | 2.10 | 1.87 | 0.00 | 0.00 | |
Maximum of Months | 25.00 | 31.10 | 25.32 | 14.90 | 22.47 | 380.00 | 730.50 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 10.03 | 13.58 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 9.54 | 21.42 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 10.65 | 30.29 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 13.15 | 37.02 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 16.36 | 45.86 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 19.42 | 49.74 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 21.50 | 48.12 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 22.05 | 49.54 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 20.89 | 34.71 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 18.36 | 29.93 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 15.14 | 17.00 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 12.10 | 12.41 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 15.80 | 32.53 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 9.54 | 12.41 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 22.05 | 49.74 | 0.00 |
Report: WaterHeaterReportMonthly
For: ELECTRIC TANK
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.962495E+09 | -874645487.8 | 0.00 | 0.00 | 744.00 | 0.00 | -87849245.6 | 58.99 | 0.00 | 0.00 |
February | 0.890831E+09 | -811505014.4 | 0.00 | 0.00 | 672.00 | 0.00 | -79325882.4 | 59.00 | 0.00 | 0.00 |
March | 0.101357E+10 | -927084471.5 | 0.00 | 0.00 | 744.00 | 0.00 | -86482383.9 | 58.99 | 0.00 | 0.00 |
April | 0.897859E+09 | -817018871.8 | 0.00 | 0.00 | 720.00 | 0.00 | -80840319.8 | 58.99 | 0.00 | 0.00 |
May | 0.868678E+09 | -790955377.5 | 0.00 | 0.00 | 744.00 | 0.00 | -77722824.3 | 58.99 | 0.00 | 0.00 |
June | 0.800823E+09 | -730929195.3 | 0.00 | 0.00 | 720.00 | 0.00 | -69893560.1 | 58.99 | 0.00 | 0.00 |
July | 0.739331E+09 | -669087357.1 | 0.00 | 0.00 | 744.00 | 0.00 | -70244031.2 | 58.99 | 0.00 | 0.00 |
August | 0.779132E+09 | -708603272.2 | 0.00 | 0.00 | 744.00 | 0.00 | -70528459.0 | 58.99 | 0.00 | 0.00 |
September | 0.749842E+09 | -679582186.4 | 0.00 | 0.00 | 720.00 | 0.00 | -70259337.3 | 58.99 | 0.00 | 0.00 |
October | 0.804833E+09 | -726457300.8 | 0.00 | 0.00 | 744.00 | 0.00 | -78375582.1 | 58.99 | 0.00 | 0.00 |
November | 0.835017E+09 | -752097279.1 | 0.00 | 0.00 | 720.00 | 0.00 | -82919352.2 | 58.99 | 0.00 | 0.00 |
December | 0.924397E+09 | -836724541.9 | 0.00 | 0.00 | 744.00 | 0.00 | -87672418.8 | 58.99 | 0.00 | 0.00 |
Annual Sum or Average | 0.102668E+11 | -.932469E+10 | 8760.00 | -942113396.8 | 58.99 | |||||
Minimum of Months | 0.739331E+09 | -927084471.5 | 0.00 | 0.00 | 672.00 | 0.00 | -87849245.6 | 58.99 | 0.00 | 0.00 |
Maximum of Months | 0.101357E+10 | -669087357.1 | 0.00 | 0.00 | 744.00 | 0.00 | -69893560.1 | 59.00 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: Environment
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING LIGHTING POWER MULTIPLIER [] | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [] | |
January | 199.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 216.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 275.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 261.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 372.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 351.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 365.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 389.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 285.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 305.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 240.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 211.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3472.67 | ||||||||||
Minimum of Months | 199.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 389.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE HEATING COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.990617E+10 | 28863.95 | 01-JAN-00:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.976247E+10 | 28863.95 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.621710E+10 | 28863.95 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.256868E+10 | 28863.95 | 01-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.360429E+09 | 28863.95 | 01-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.434070E+09 | 28863.95 | 10-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.426282E+10 | 28863.95 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.749520E+10 | 28863.95 | 01-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.410069E+11 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.990617E+10 | 28863.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE HEATING COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.521465E+11 | 87392.23 | 01-JAN-00:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.487518E+11 | 87392.23 | 01-FEB-00:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.240608E+11 | 87392.23 | 01-MAR-01:23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.660406E+10 | 87392.23 | 02-APR-01:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 18412858.50 | 58922.86 | 02-MAY-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.142363E+09 | 31397.44 | 31-OCT-05:38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.190413E+11 | 87392.23 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.389754E+11 | 87392.23 | 01-DEC-00:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.189741E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.521465E+11 | 87392.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: ZONE3UNITHEATERHEATINGCOIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum}[W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.997396E+11 | 160101.53 | 01-JAN-20:54 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.967347E+11 | 185633.59 | 06-FEB-00:51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.249434E+11 | 107136.29 | 22-MAR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.771352E+09 | 23094.37 | 02-APR-05:55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.182405E+11 | 104386.11 | 23-NOV-01:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.588265E+11 | 162789.42 | 31-DEC-21:52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.299256E+12 | |||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.997396E+11 | 185633.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PSZ-OFFICE COOLING COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.309116E+09 | 0.281883E+09 | 4920.23 | 07-APR-16:00 | 4599.35 | 0.00 |
May | 0.00 | 0.00 | 0.200223E+10 | 0.176166E+10 | 21527.38 | 31-MAY-05:03 | 17574.11 | 0.00 |
June | 0.00 | 0.00 | 0.860340E+10 | 0.651357E+10 | 25863.07 | 19-JUN-05:01 | 13643.74 | 0.00 |
July | 0.00 | 0.00 | 0.127257E+11 | 0.900763E+10 | 26680.05 | 22-JUL-05:01 | 12626.76 | 0.00 |
August | 0.00 | 0.00 | 0.128721E+11 | 0.985256E+10 | 26716.70 | 04-AUG-05:01 | 13364.73 | 0.00 |
September | 0.00 | 0.00 | 0.683906E+10 | 0.544110E+10 | 25600.75 | 14-SEP-05:01 | 13407.55 | 0.00 |
October | 0.00 | 0.00 | 0.215119E+10 | 0.165724E+10 | 8815.47 | 04-OCT-15:30 | 6883.20 | 0.00 |
November | 0.00 | 0.00 | 15812839.14 | 14646954.44 | 1183.83 | 04-NOV-13:40 | 1089.24 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.455186E+11 | 0.345303E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.128721E+11 | 0.985256E+10 | 26716.70 | 17574.11 | 0.00 |
Report: CoilReportMonthly
For: PSZ-FINE STORAGE COOLING COIL
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum}[W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:01 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:02 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:03 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.123014E+10 | 0.103337E+10 | 25874.50 | 31-MAY-14:00 | 20017.98 | 0.00 |
June | 0.00 | 0.00 | 0.144802E+11 | 0.105487E+11 | 73809.91 | 25-JUN-12:13 | 41564.20 | 0.00 |
July | 0.00 | 0.00 | 0.319826E+11 | 0.216305E+11 | 74237.42 | 30-JUL-11:33 | 41862.70 | 0.00 |
August | 0.00 | 0.00 | 0.322474E+11 | 0.236787E+11 | 76723.64 | 03-AUG-05:01 | 38420.25 | 0.00 |
September | 0.00 | 0.00 | 0.878013E+10 | 0.674351E+10 | 66205.66 | 07-SEP-17:10 | 40983.22 | 0.00 |
October | 0.00 | 0.00 | 0.329360E+09 | 0.231635E+09 | 11640.73 | 04-OCT-14:00 | 8565.40 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:03 | 0.00 | 0.00 |
Annual Sum or Average | 0.890498E+11 | 0.638664E+11 | ||||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.322474E+11 | 0.236787E+11 | 76723.64 | 41862.70 | 0.00 |
Report: FanReportMonthly
For: ZONE3UNITHEATERFAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.941475E+09 | 0.06 | 451.68 | 01-JAN-00:01 | 0.08 |
February | 0.887048E+09 | 0.06 | 451.68 | 01-FEB-00:02 | 0.08 |
March | 0.435168E+09 | 0.03 | 451.68 | 01-MAR-00:03 | 0.08 |
April | 33356661.20 | 0.00 | 451.68 | 02-APR-00:50 | 0.08 |
May | 0.00 | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 |
November | 0.282165E+09 | 0.02 | 451.68 | 19-NOV-03:00 | 0.08 |
December | 0.931999E+09 | 0.06 | 451.68 | 01-DEC-00:03 | 0.08 |
Annual Sum or Average | 0.351121E+10 | 0.02 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.941475E+09 | 0.06 | 451.68 | 0.08 |
Report: FanReportMonthly
For: PSZ-OFFICE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.131489E+10 | 0.57 | 1205.86 | 02-JAN-14:50 | 0.94 |
February | 0.121454E+10 | 0.59 | 1205.86 | 01-FEB-14:10 | 0.94 |
March | 0.133970E+10 | 0.44 | 1205.86 | 01-MAR-08:00 | 0.94 |
April | 0.121885E+10 | 0.38 | 1205.86 | 01-APR-13:50 | 0.93 |
May | 0.124752E+10 | 0.37 | 1205.86 | 02-MAY-14:00 | 0.93 |
June | 0.125855E+10 | 0.38 | 1205.86 | 01-JUN-16:20 | 0.93 |
July | 0.123546E+10 | 0.37 | 1205.86 | 05-JUL-07:40 | 0.92 |
August | 0.132787E+10 | 0.40 | 1205.86 | 02-AUG-09:20 | 0.92 |
September | 0.120861E+10 | 0.37 | 1205.86 | 01-SEP-09:20 | 0.93 |
October | 0.119839E+10 | 0.35 | 1205.86 | 02-OCT-06:30 | 0.93 |
November | 0.118605E+10 | 0.41 | 1205.86 | 01-NOV-17:00 | 0.94 |
December | 0.125278E+10 | 0.43 | 1205.86 | 01-DEC-15:50 | 0.94 |
Annual Sum or Average | 0.150032E+11 | 0.42 | |||
Minimum of Months | 0.118605E+10 | 0.35 | 1205.86 | 0.92 | |
Maximum of Months | 0.133970E+10 | 0.59 | 1205.86 | 0.94 |
Report: FanReportMonthly
For: PSZ-FINE STORAGE_ADDAQ SUPPLY FAN
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportFAN ELECTRIC ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRIC POWER {Maximum}[W] | FAN ELECTRIC POWER {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.415473E+10 | 0.79 | 2818.47 | 02-JAN-09:40 | 0.90 |
February | 0.381680E+10 | 0.78 | 2818.47 | 01-FEB-10:20 | 0.90 |
March | 0.369819E+10 | 0.73 | 2818.47 | 11-MAR-08:30 | 0.90 |
April | 0.299235E+10 | 0.51 | 2818.47 | 01-APR-07:20 | 0.90 |
May | 0.290545E+10 | 0.35 | 2818.47 | 20-MAY-14:50 | 0.90 |
June | 0.297633E+10 | 0.39 | 2818.47 | 03-JUN-14:40 | 0.89 |
July | 0.305365E+10 | 0.44 | 2818.47 | 01-JUL-09:40 | 0.89 |
August | 0.324754E+10 | 0.46 | 2818.47 | 02-AUG-16:00 | 0.88 |
September | 0.283688E+10 | 0.37 | 2818.47 | 01-SEP-11:10 | 0.89 |
October | 0.279326E+10 | 0.33 | 2818.47 | 05-OCT-11:50 | 0.89 |
November | 0.323190E+10 | 0.64 | 2818.47 | 01-NOV-06:20 | 0.90 |
December | 0.382494E+10 | 0.78 | 2818.47 | 01-DEC-13:00 | 0.90 |
Annual Sum or Average | 0.395320E+11 | 0.55 | |||
Minimum of Months | 0.279326E+10 | 0.33 | 2818.47 | 0.88 | |
Maximum of Months | 0.415473E+10 | 0.79 | 2818.47 | 0.90 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 2.73 | 0.00 |
February | 2.99 | 0.00 |
March | 2.60 | 0.05 |
April | 1.20 | 0.47 |
May | 0.75 | 2.20 |
June | 2.06 | 0.25 |
July | 2.57 | 0.01 |
August | 3.72 | 0.02 |
September | 1.91 | 2.02 |
October | 1.14 | 2.12 |
November | 1.95 | 0.27 |
December | 3.14 | 0.01 |
Annual Sum or Average | 26.77 | 0.37 |
Minimum of Months | 0.75 | 0.00 |
Maximum of Months | 3.72 | 2.20 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.35 | 0.00 |
February | 0.76 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.08 | 0.00 |
November | 0.00 | 0.00 |
December | 0.04 | 0.00 |
Annual Sum or Average | 1.24 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.76 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.08 | 0.00 |
July | 1.14 | 0.00 |
August | 2.62 | 0.00 |
September | 0.08 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 3.93 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 2.62 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.131489E+10 | 0.141698E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.121454E+10 | 0.139001E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.133970E+10 | 0.897622E+10 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.130346E+10 | 0.374935E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.178943E+10 | 0.530983E+09 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.353264E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.458023E+10 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.475280E+10 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.300360E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.177019E+10 | 0.640733E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.119042E+10 | 0.618224E+10 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.125278E+10 | 0.108277E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.270447E+11 | 0.589770E+11 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.119042E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.475280E+10 | 0.141698E+11 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRIC ENERGY [J] | AIR SYSTEM GAS ENERGY [J] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.415473E+10 | 0.734424E+11 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.381680E+10 | 0.685482E+11 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.369819E+10 | 0.348429E+11 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.299235E+10 | 0.973366E+10 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.326790E+10 | 27621196.13 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.713853E+10 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.121509E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.125378E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.534134E+10 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.288694E+10 | 0.218712E+09 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.323190E+10 | 0.275150E+11 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.382494E+10 | 0.560383E+11 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.650423E+11 | 0.270367E+12 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.288694E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.125378E+11 | 0.734424E+11 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.131489E+10 | 0.00 | 0.990617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.121454E+10 | 0.00 | 0.976247E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133970E+10 | 0.00 | 0.621710E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.121885E+10 | 0.309116E+09 | 0.256868E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.124752E+10 | 0.200223E+10 | 0.360429E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.125855E+10 | 0.860340E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.123546E+10 | 0.127257E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.132787E+10 | 0.128721E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.120861E+10 | 0.683906E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.119839E+10 | 0.215119E+10 | 0.434070E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.118605E+10 | 15812839.14 | 0.426282E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.125278E+10 | 0.00 | 0.749520E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.150032E+11 | 0.455186E+11 | 0.410069E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.118605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.133970E+10 | 0.128721E+11 | 0.990617E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.415473E+10 | 0.00 | 0.521465E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.381680E+10 | 0.00 | 0.487518E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.369819E+10 | 0.00 | 0.240608E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.299235E+10 | 0.00 | 0.660406E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.290545E+10 | 0.123014E+10 | 18412858.50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.297633E+10 | 0.144802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.305365E+10 | 0.319826E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.324754E+10 | 0.322474E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.283688E+10 | 0.878013E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.279326E+10 | 0.329360E+09 | 0.142363E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.323190E+10 | 0.00 | 0.190413E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.382494E+10 | 0.00 | 0.389754E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.395320E+11 | 0.890498E+11 | 0.189741E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.279326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.415473E+10 | 0.322474E+11 | 0.521465E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.131489E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141698E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.121454E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.139001E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.133970E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.897622E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.121885E+10 | 0.00 | 0.00 | 0.00 | 84608817.65 | 0.00 | 0.374935E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.124752E+10 | 0.00 | 0.00 | 0.00 | 0.541909E+09 | 0.00 | 0.530983E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.125855E+10 | 0.00 | 0.00 | 0.00 | 0.227409E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.123546E+10 | 0.00 | 0.00 | 0.00 | 0.334477E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.132787E+10 | 0.00 | 0.00 | 0.00 | 0.342493E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.120861E+10 | 0.00 | 0.00 | 0.00 | 0.179499E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.119839E+10 | 0.00 | 0.00 | 0.00 | 0.571800E+09 | 0.00 | 0.640733E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.118605E+10 | 0.00 | 0.00 | 0.00 | 4369974.09 | 0.00 | 0.618224E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.125278E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.108277E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.150032E+11 | 0.00 | 0.00 | 0.00 | 0.120415E+11 | 0.00 | 0.589770E+11 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.118605E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.133970E+10 | 0.00 | 0.00 | 0.00 | 0.342493E+10 | 0.00 | 0.141698E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PSZ-FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportAIR SYSTEM FAN ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRIC ENERGY [J] | AIR SYSTEM HEATING COIL GAS ENERGY [J] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRIC ENERGY [J] | AIR SYSTEM HUMIDIFIER GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRIC ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRIC ENERGY [J] | |
January | 0.415473E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.734424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.381680E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.685482E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.369819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.348429E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.299235E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.973366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.290545E+10 | 0.00 | 0.00 | 0.00 | 0.362443E+09 | 0.00 | 27621196.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.297633E+10 | 0.00 | 0.00 | 0.00 | 0.416220E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.305365E+10 | 0.00 | 0.00 | 0.00 | 0.909725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.324754E+10 | 0.00 | 0.00 | 0.00 | 0.929029E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.283688E+10 | 0.00 | 0.00 | 0.00 | 0.250446E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.279326E+10 | 0.00 | 0.00 | 0.00 | 93670741.67 | 0.00 | 0.218712E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.323190E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.275150E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.382494E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.560383E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.395320E+11 | 0.00 | 0.00 | 0.00 | 0.255103E+11 | 0.00 | 0.270367E+12 | 0.00 | 0.00 | 0.00 | 0.00 | |
Minimum of Months | 0.279326E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.415473E+10 | 0.00 | 0.00 | 0.00 | 0.929029E+10 | 0.00 | 0.734424E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE1 OFFICE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 399123.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.302106E+10 | 0.00 | 3487.40 | 0.17 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.299254E+10 | 0.00 | 0.00 | 0.18 |
March | 0.158314E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.228640E+10 | 0.00 | 0.00 | 0.18 |
April | 0.405573E+09 | 7525192.93 | 0.00 | 221295.81 | 0.00 | 0.104085E+10 | 85043070.73 | 0.00 | 0.17 |
May | 0.384979E+09 | 66458223.23 | 0.00 | 1763777.38 | 0.00 | 0.126455E+09 | 0.408544E+09 | 0.00 | 0.17 |
June | 27156211.21 | 0.948147E+09 | 0.00 | 2973245.41 | 134659.54 | 0.00 | 98262436.99 | 0.00 | 0.18 |
July | 0.00 | 0.218017E+10 | 0.00 | 2031964.78 | 0.00 | 0.00 | 2003142.45 | 0.00 | 0.17 |
August | 629902.67 | 0.186691E+10 | 0.00 | 3352757.55 | 0.00 | 0.00 | 34453381.95 | 0.00 | 0.18 |
September | 71441888.97 | 0.563152E+09 | 0.00 | 3671125.93 | 259160.13 | 0.00 | 0.303483E+09 | 0.00 | 0.17 |
October | 0.462470E+09 | 75263415.45 | 0.00 | 1320847.59 | 5552.22 | 0.173753E+09 | 0.318632E+09 | 0.00 | 0.16 |
November | 0.288124E+09 | 0.00 | 0.00 | 16820.91 | 0.00 | 0.162693E+10 | 20086838.12 | 0.00 | 0.16 |
December | 435313.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.268986E+10 | 0.00 | 0.00 | 0.17 |
Annual Sum or Average | 0.179952E+10 | 0.570763E+10 | 0.00 | 15351835.37 | 399371.89 | 0.139579E+11 | 0.127051E+10 | 3487.40 | 0.17 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 |
Maximum of Months | 0.462470E+09 | 0.218017E+10 | 0.00 | 3671125.93 | 259160.13 | 0.302106E+10 | 0.408544E+09 | 3487.40 | 0.18 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE2 FINE STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.852083E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.783382E+10 | 0.00 | 0.00 | 0.23 |
February | 0.995463E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.782013E+10 | 0.00 | 0.00 | 0.23 |
March | 0.221117E+10 | 0.00 | 0.00 | 0.00 | 8304345.82 | 0.340723E+10 | 0.00 | 0.00 | 0.20 |
April | 0.219247E+10 | 0.00 | 0.00 | 0.00 | 13336883.31 | 0.857213E+09 | 0.00 | 0.00 | 0.17 |
May | 0.222995E+10 | 0.108647E+09 | 0.00 | 95022.64 | 0.00 | 1830858.37 | 28932229.76 | 0.00 | 0.17 |
June | 0.628117E+09 | 0.121828E+10 | 0.00 | 2675690.52 | 5360841.85 | 0.00 | 0.408592E+09 | 0.00 | 0.18 |
July | 54705334.59 | 0.409260E+10 | 0.00 | 1138546.37 | 82200.11 | 0.00 | 95004161.78 | 0.00 | 0.18 |
August | 0.183459E+09 | 0.380454E+10 | 0.00 | 4248022.01 | 822260.89 | 0.00 | 0.181121E+09 | 0.00 | 0.19 |
September | 0.115590E+10 | 0.623770E+09 | 0.00 | 3586835.52 | 0.00 | 0.00 | 0.513614E+09 | 0.00 | 0.17 |
October | 0.237287E+10 | 8049642.23 | 0.00 | 114185.73 | 57822.09 | 57158825.08 | 23444334.58 | 0.00 | 0.16 |
November | 0.165300E+10 | 0.00 | 0.00 | 0.00 | 557677.40 | 0.269421E+10 | 0.00 | 14202.94 | 0.19 |
December | 0.924765E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.591709E+10 | 0.00 | 0.00 | 0.21 |
Annual Sum or Average | 0.154540E+11 | 0.985588E+10 | 0.00 | 11858302.79 | 28522031.49 | 0.285887E+11 | 0.125071E+10 | 14202.94 | 0.19 |
Minimum of Months | 54705334.59 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.16 |
Maximum of Months | 0.237287E+10 | 0.409260E+10 | 0.00 | 4248022.01 | 13336883.31 | 0.783382E+10 | 0.513614E+09 | 14202.94 | 0.23 |
Report: MechanicalVentilationLoadsMonthly
For: ZONE3 BULK STORAGE
Timestamp: 2020-06-03 19:11:33
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |