Values gathered over 8760.00 hoursTotal Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
Total Site Energy | 1717.25 | 344.68 | 344.68 |
Net Site Energy | 1717.25 | 344.68 | 344.68 |
Total Source Energy | 4798.94 | 963.22 | 963.22 |
Net Source Energy | 4798.94 | 963.22 | 963.22 |
Site=>Source Conversion Factor | |
Electricity | 3.167 |
Natural Gas | 1.084 |
District Cooling | 1.056 |
District Heating | 3.613 |
Steam | 1.200 |
Gasoline | 1.050 |
Diesel | 1.050 |
Coal | 1.050 |
Fuel Oil No 1 | 1.050 |
Fuel Oil No 2 | 1.050 |
Propane | 1.050 |
Other Fuel 1 | 1.000 |
Other Fuel 2 | 1.000 |
Area [m2] | |
Total Building Area | 4982.19 |
Net Conditioned Building Area | 4982.19 |
Unconditioned Building Area | 0.00 |
Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | 117.95 | 173.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 177.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 232.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 50.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 705.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 11.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 114.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 133.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 1410.20 | 307.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | General | 117.95 | 173.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 177.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 232.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 50.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 584.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 120.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 0.64 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 11.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 114.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 0.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 | |
Water Heater | 0.00 | 133.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
Heating | Unassigned | 117.95 | 173.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | Unassigned | 177.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | GENERAL | 232.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | Unassigned | 50.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | GENERAL | 705.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | Unassigned | 11.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | Unassigned | 114.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | Unassigned | 0.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | Unassigned | 0.00 | 133.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 271.06 |
Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 56.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 82.30 | 61.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 143.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 283.05 | 61.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
Lighting | 56.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HVAC | 82.30 | 61.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Other | 143.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total | 283.05 | 61.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.05 |
Electricity [GJ] | Percent Electricity [%] | |
Fuel-Fired Power Generation | 0.000 | 0.00 |
High Temperature Geothermal* | 0.000 | 0.00 |
Photovoltaic Power | 0.000 | 0.00 |
Wind Power | 0.000 | 0.00 |
Power Conversion | 0.000 | 0.00 |
Net Decrease in On-Site Storage | 0.000 | 0.00 |
Total On-Site Electric Sources | 0.000 | 0.00 |
Electricity Coming From Utility | 1410.199 | 100.00 |
Surplus Electricity Going To Utility | 0.000 | 0.00 |
Net Electricity From Utility | 1410.199 | 100.00 |
Total On-Site and Utility Electric Sources | 1410.199 | 100.00 |
Total Electricity End Uses | 1410.199 | 100.00 |
Heat [GJ] | Percent Heat [%] | |
Water-Side Heat Recovery | 0.00 | |
Air to Air Heat Recovery for Cooling | 0.00 | |
Air to Air Heat Recovery for Heating | 0.00 | |
High-Temperature Geothermal* | 0.00 | |
Solar Water Thermal | 0.00 | |
Solar Air Thermal | 0.00 | |
Total On-Site Thermal Sources | 0.00 |
Water [m3] | Percent Water [%] | |
Rainwater Collection | 0.00 | 0.00 |
Condensate Collection | 0.00 | 0.00 |
Groundwater Well | 0.00 | 0.00 |
Total On Site Water Sources | 0.00 | 0.00 |
- | - | - |
Initial Storage | 0.00 | 0.00 |
Final Storage | 0.00 | 0.00 |
Change in Storage | 0.00 | 0.00 |
- | - | - |
Water Supplied by Utility | 271.06 | 100.00 |
- | - | - |
Total On Site, Change in Storage, and Utility Water Sources | 271.06 | 100.00 |
Total Water End Uses | 271.06 | 100.00 |
Degrees [deltaC] | |
Tolerance for Zone Heating Setpoint Not Met Time | 0.56 |
Tolerance for Zone Cooling Setpoint Not Met Time | 0.56 |
Facility [Hours] | |
Time Setpoint Not Met During Occupied Heating | 207.17 |
Time Setpoint Not Met During Occupied Cooling | 187.17 |
Time Not Comfortable Based on Simple ASHRAE 55-2004 | 2314.17 |
Table of Contents
TopNAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
| Environment |NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
| Environment |NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
| Environment |NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
| Environment |NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
| Environment |NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
| Environment |NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
| Environment |ZoneCoolingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneHeatingSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ZoneElectricSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |SpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |PeakSpaceGainsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 | FIRSTFLOOR_PLENUM | MIDFLOOR_PLENUM | TOPFLOOR_PLENUM |SpaceGainComponentsAtCoolingPeakMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |EnergyConsumptionElectricityNaturalGasMonthly
| Meter |EndUseEnergyConsumptionElectricityMonthly
| Meter |EndUseEnergyConsumptionNaturalGasMonthly
| Meter |PeakEnergyEndUseElectricityPart1Monthly
| Meter |PeakEnergyEndUseElectricityPart2Monthly
| Meter |ElectricComponentsOfPeakDemandMonthly
| Meter |PeakEnergyEndUseNaturalGasMonthly
| Meter |SetpointsNotMetWithTemperaturesMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |ComfortReportSimple55Monthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |OccupantComfortDataSummaryMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |DXReportMonthly
| PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |WindowReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowEnergyReportMonthly
| PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW |WindowZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |WindowEnergyZoneSummaryMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AverageOutdoorConditionsMonthly
| Environment |OutdoorConditionsMaximumDryBulbMonthly
| Environment |OutdoorConditionsMinimumDryBulbMonthly
| Environment |OutdoorConditionsMaximumWetBulbMonthly
| Environment |OutdoorConditionsMaximumDewPointMonthly
| Environment |OutdoorGroundConditionsMonthly
| Environment |WaterHeaterReportMonthly
| SWHSYS1 WATER HEATER |DaylightingReportMonthly
| PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_4_DAYLCTRL |CoilReportMonthly
| CORE_BOTTOM VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | CORE_MID VAV BOX REHEAT COIL | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | CORE_TOP VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | PACU_VAV_BOT HEATING COIL | PACU_VAV_MID HEATING COIL | PACU_VAV_TOP HEATING COIL | PACU_VAV_BOT COOLING COIL | PACU_VAV_MID COOLING COIL | PACU_VAV_TOP COOLING COIL |PlantLoopDemandReportMonthly
| SWHSYS1 |FanReportMonthly
| PACU_VAV_BOT FAN | PACU_VAV_MID FAN | PACU_VAV_TOP FAN |PumpReportMonthly
| SWHSYS1 PUMP |CondLoopDemandReportMonthly
| SWHSYS1 |ZoneTemperatureOscillationReportMonthly
| CORE_BOTTOM | TOPFLOOR_PLENUM | MIDFLOOR_PLENUM | FIRSTFLOOR_PLENUM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |AirLoopSystemEnergyAndWaterUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentLoadsMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |AirLoopSystemComponentEnergyUseMonthly
| PACU_VAV_BOT | PACU_VAV_MID | PACU_VAV_TOP |MechanicalVentilationLoadsMonthly
| CORE_BOTTOM | CORE_MID | CORE_TOP | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_4 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_4 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_4 |HeatEmissionsReportMonthly
| Environment |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
GeneralValue | |
Program Version and Build | EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:31 |
RunPeriod | RUNPERIOD 1 |
Weather File | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Latitude [deg] | 39.72 |
Longitude [deg] | -104.8 |
Elevation [m] | 1726.00 |
Time Zone | -7.0 |
North Axis Angle [deg] | 0.00 |
Rotation for Appendix G [deg] | 0.00 |
Hours Simulated [hrs] | 8760.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 652.62 | 195.79 | 130.53 | 195.79 | 130.53 |
Gross Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Above Ground Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
Gross Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Above Ground Wall Area [m2] | 1977.67 | 593.30 | 395.53 | 593.30 | 395.53 |
Window Opening Area [m2] | 652.62 | 195.79 | 130.53 | 195.79 | 130.53 |
Gross Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Above Ground Window-Wall Ratio [%] | 33.00 | 33.00 | 33.00 | 33.00 | 33.00 |
Total | |
Gross Roof Area [m2] | 1660.73 |
Skylight Area [m2] | 0.00 |
Skylight-Roof Ratio [%] | 0.00 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
CORE_BOTTOM | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.6636 | 18.58 | 24.8342 |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 2024.76 | 1.00 | 202.84 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.6636 | 18.58 | 8.0700 |
CORE_TOP | 983.54 | Yes | Yes | 2698.04 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.6636 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 6.6636 | 18.58 | 8.0700 |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 6.6636 | 18.58 | 8.0695 |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 6.6636 | 18.58 | 8.0699 |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 6.6636 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 6.6636 | 18.58 | 8.0700 |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 6.6636 | 18.58 | 8.0695 |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 6.6636 | 18.58 | 8.0699 |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 6.6636 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 6.6636 | 18.58 | 8.0700 |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 360.08 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 6.6636 | 18.58 | 8.0695 |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 568.77 | 1.00 | 136.92 | 0.00 | 65.26 | 65.26 | 6.6636 | 18.58 | 8.0699 |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 360.05 | 1.00 | 91.28 | 0.00 | 43.51 | 43.51 | 6.6636 | 18.58 | 8.0700 |
Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 652.62 | 652.62 | 6.6636 | 18.58 | 11.3794 | |||
Conditioned Total | 4982.19 | 13667.13 | 1369.16 | 0.00 | 652.62 | 652.62 | 6.6636 | 18.58 | 11.3794 | |||
Unconditioned Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Not Part of Total | 4982.19 | 6074.28 | 608.51 | 0.00 | 0.00 | 0.00 | 0.0000 | 0.0000 |
Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
CORE_BOTTOM | 983.54 | Yes | Yes | 1.00 | CORE_BOTTOM | GENERAL | CORE_BOTTOM | 6.6636 | 18.58 | 24.8342 | |
TOPFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | TOPFLOOR_PLENUM | GENERAL | TOPFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
MIDFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | MIDFLOOR_PLENUM | GENERAL | MIDFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
FIRSTFLOOR_PLENUM | 1660.73 | Yes | No | 1.00 | FIRSTFLOOR_PLENUM | GENERAL | FIRSTFLOOR_PLENUM | 0.0000 | 0.00 | 0.0000 | |
CORE_MID | 983.54 | Yes | Yes | 1.00 | CORE_MID | GENERAL | CORE_MID | 6.6636 | 18.58 | 8.0700 | |
CORE_TOP | 983.54 | Yes | Yes | 1.00 | CORE_TOP | GENERAL | CORE_TOP | 6.6636 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_3 | GENERAL | PERIMETER_TOP_ZN_3 | 6.6636 | 18.58 | 8.0700 | |
PERIMETER_TOP_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_2 | GENERAL | PERIMETER_TOP_ZN_2 | 6.6636 | 18.58 | 8.0695 | |
PERIMETER_TOP_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_1 | GENERAL | PERIMETER_TOP_ZN_1 | 6.6636 | 18.58 | 8.0699 | |
PERIMETER_TOP_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_TOP_ZN_4 | GENERAL | PERIMETER_TOP_ZN_4 | 6.6636 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_3 | GENERAL | PERIMETER_BOT_ZN_3 | 6.6636 | 18.58 | 8.0700 | |
PERIMETER_BOT_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_2 | GENERAL | PERIMETER_BOT_ZN_2 | 6.6636 | 18.58 | 8.0695 | |
PERIMETER_BOT_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_1 | GENERAL | PERIMETER_BOT_ZN_1 | 6.6636 | 18.58 | 8.0699 | |
PERIMETER_BOT_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_BOT_ZN_4 | GENERAL | PERIMETER_BOT_ZN_4 | 6.6636 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_3 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_3 | GENERAL | PERIMETER_MID_ZN_3 | 6.6636 | 18.58 | 8.0700 | |
PERIMETER_MID_ZN_2 | 131.26 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_2 | GENERAL | PERIMETER_MID_ZN_2 | 6.6636 | 18.58 | 8.0695 | |
PERIMETER_MID_ZN_1 | 207.34 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_1 | GENERAL | PERIMETER_MID_ZN_1 | 6.6636 | 18.58 | 8.0699 | |
PERIMETER_MID_ZN_4 | 131.25 | Yes | Yes | 1.00 | PERIMETER_MID_ZN_4 | GENERAL | PERIMETER_MID_ZN_4 | 6.6636 | 18.58 | 8.0700 | |
Total | 4982.19 | 6.6636 | 9.29 | 11.3794 | |||||||
Conditioned Total | 4982.19 | 6.6636 | 9.29 | 11.3794 | |||||||
Unconditioned Total | 0.00 | 0.0000 | 0.00 | 0.0000 | |||||||
Not Part of Total | 4982.19 | 0.0000 | 0.00 | 0.0000 |
Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
GENERAL | 4982.19 | 4982.19 | 0.00 | 4982.19 | 6.6636 | 18.58 | 11.3794 |
Total | 4982.19 | 4982.19 | 0.00 | 4982.19 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
End UsesElectricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Time of Peak | 06-FEB-07:10 | 21-DEC-09:39 | - | - | - | - | - | - | - | - | - | - | 03-JAN-12:09 |
Heating | 166145.31 | 92027.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 8334.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 21098.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 243.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 5961.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 6.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 9462.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total End Uses | 201790.88 | 101490.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
Heating | General | 166145.31 | 92027.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | LightsWired | 8334.71 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | MiscPlug | 15327.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
ElevatorLift | 5727.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
ElevatorLightsFan | 43.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Exterior Equipment | Transformer | 243.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | General | 5961.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | General | 6.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Water Heater | 0.00 | 9462.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Values gathered over 8760.00 hoursSource Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
Heating | 373.53 | 187.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 561.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 735.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 160.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 2234.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 37.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 363.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.46 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 145.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 4466.10 | 332.84 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 74.97 | 37.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 112.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 147.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 32.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 448.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 7.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 72.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 29.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 896.41 | 66.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
Heating | 74.97 | 37.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling | 112.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting | 147.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting | 32.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment | 448.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment | 7.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans | 72.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps | 0.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems | 0.00 | 29.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Total Source Energy End Use Components | 896.41 | 66.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
AirTerminal:SingleDuct:VAV:ReheatDesign Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | |
CORE_BOTTOM VAV BOX COMPONENT | 3.43 | 0.218367 | 0.186000 | 0.638370 | 0.582311 | 0.500000 | 0.001745 |
CORE_MID VAV BOX COMPONENT | 2.51 | 0.298849 | 0.254000 | 0.636982 | 0.796931 | 0.500000 | 0.001275 |
CORE_TOP VAV BOX COMPONENT | 2.67 | 0.280479 | 0.238000 | 0.635948 | 0.747945 | 0.500000 | 0.001358 |
PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | 0.855427 | 0.184693 | 0.157000 | 0.134302 | 0.492516 | 0.500000 | 0.002063 |
PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | 0.967469 | 0.103385 | 0.088000 | 0.085137 | 0.300000 | 0.500000 | 0.003685 |
PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | 1.17 | 0.135520 | 0.115000 | 0.134069 | 0.361386 | 0.500000 | 0.002811 |
PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | 1.13 | 0.088632 | 0.075000 | 0.084632 | 0.300000 | 0.500000 | 0.004299 |
PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | 0.656633 | 0.240609 | 0.205000 | 0.134610 | 0.641624 | 0.500000 | 0.001583 |
PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | 0.789001 | 0.126770 | 0.108000 | 0.085212 | 0.338054 | 0.500000 | 0.003005 |
PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | 0.916540 | 0.172378 | 0.147000 | 0.134731 | 0.459676 | 0.500000 | 0.002210 |
PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | 0.872763 | 0.114596 | 0.097000 | 0.084658 | 0.305590 | 0.500000 | 0.003325 |
PERIMETER_MID_ZN_3 VAV BOX COMPONENT | 0.739860 | 0.213543 | 0.182000 | 0.134654 | 0.569447 | 0.500000 | 0.001784 |
PERIMETER_MID_ZN_2 VAV BOX COMPONENT | 0.957302 | 0.300000 | 0.500000 | 0.003647 | |||
PERIMETER_MID_ZN_1 VAV BOX COMPONENT | 1.05 | 0.150434 | 0.128000 | 0.134430 | 0.401158 | 0.500000 | 0.002533 |
PERIMETER_MID_ZN_4 VAV BOX COMPONENT | 1.04 | 0.096350 | 0.082000 | 0.085120 | 0.300000 | 0.500000 | 0.003954 |
Design Size Nominal Capacity [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | 17306.43 |
CORE_MID VAV BOX REHEAT COIL | 23552.52 |
CORE_TOP VAV BOX REHEAT COIL | 41449.40 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | 18866.39 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | 12424.65 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | 18986.18 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | 12424.44 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | 14029.28 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | 9332.44 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | 14145.69 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | 9332.35 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | 14711.88 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | 9760.68 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | 14814.24 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | 9760.58 |
Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
PACU_VAV_BOT | 3.33 | 1.08 | 6.67 | 2.17 | 5.91 | 5.91 | 0.300000 | 0.366056 | 5.91 |
PACU_VAV_MID | 3.15 | 1.08 | 6.29 | 2.68 | 5.31 | 5.31 | 0.300000 | 0.504750 | 5.31 |
PACU_VAV_TOP | 3.39 | 1.07 | 6.79 | 3.84 | 6.18 | 6.18 | 0.300000 | 0.621341 | 6.18 |
Maximum Outdoor Air Flow Rate [m3/s] | |
PACU_VAV_BOT_OA_CONTROLLER | 5.91 |
PACU_VAV_MID_OA_CONTROLLER | 5.31 |
PACU_VAV_TOP_OA_CONTROLLER | 6.18 |
Design Size High Speed Rated Air Flow Rate [m3/s] | Design Size High Speed Gross Rated Total Cooling Capacity [W] | Design Size High Speed Rated Sensible Heat Ratio | Design Size Low Speed Rated Air Flow Rate [m3/s] | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | Design Size Low Speed Gross Rated Sensible Heat Ratio | |
PACU_VAV_BOT COOLING COIL | 5.91 | 97905.89 | 0.800655 | 1.97 | 32632.03 | 0.800655 |
PACU_VAV_MID COOLING COIL | 5.31 | 87824.52 | 0.800655 | 1.77 | 29271.91 | 0.800655 |
PACU_VAV_TOP COOLING COIL | 6.18 | 102350.32 | 0.800655 | 2.06 | 34113.36 | 0.800655 |
Design Size Nominal Capacity [W] | |
PACU_VAV_BOT HEATING COIL | 24025.31 |
PACU_VAV_MID HEATING COIL | 25341.40 |
PACU_VAV_TOP HEATING COIL | 24255.62 |
Design Size Maximum Flow Rate [m3/s] | |
PACU_VAV_BOT FAN | 5.91 |
PACU_VAV_MID FAN | 5.31 |
PACU_VAV_TOP FAN | 6.18 |
Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
SWHSYS1 | 0.000054 | 0.006435 |
Design Flow Rate [m3/s] | Design Power Consumption [W] | |
SWHSYS1 PUMP | 0.000054 | 6.85 |
Use Side Design Flow Rate [m3/s] | |
SWHSYS1 WATER HEATER | 0.000054 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other SurfacesNone |
Possible Shadow Receivers | |
PERIMETER_TOP_ZN_3_WALL_NORTH | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_TOP_ZN_2_WALL_EAST | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_TOP_ZN_1_WALL_SOUTH | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_TOP_ZN_4_WALL_WEST | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | |
PERIMETER_BOT_ZN_3_WALL_NORTH | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | |
PERIMETER_BOT_ZN_2_WALL_EAST | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | |
PERIMETER_BOT_ZN_4_WALL_WEST | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | |
PERIMETER_MID_ZN_3_WALL_NORTH | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | |
PERIMETER_MID_ZN_2_WALL_EAST | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | |
PERIMETER_MID_ZN_1_WALL_SOUTH | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | |
PERIMETER_MID_ZN_4_WALL_WEST | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Time Not Meeting the Adaptive Comfort Models during Occupied HoursASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
VersionVersion ID | |
1 | 22.1 |
#TimeSteps | Minutes per TimeStep {minutes} | |
1 | 6 | 10 |
Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
1 | 1 | 20 | 2 | 8 |
Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
1 | Yes | Yes | Yes | No | Yes | No |
Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
1 | 0.556 | 0.556 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 7.10 | 3.00 | -1.00 | 0.80 | -0.20 | 4.80 | 6.10 | 13.70 | 22.20 | 22.70 | 21.70 | 18.50 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Normal | Daylighting {dimensionless} | |
1 | 1.000 | 1.000 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
1 | Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 | 39.72 | -104.75 | -7.00 | 1726.00 | 82237 | 0.9774 |
Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
1 | Correlation | NA | 9.95 | 23.70 | NA |
Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
1 | OfficeMedium | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
1 | TARP |
Value {Anisotropic} | |
1 | Anisotropic |
Value {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
|
1 | ThirdOrderBackwardDifference |
Simulation {Yes/No} | Carbon Dioxide Concentration | |
1 | No | N/A |
Simulation {Yes/No} | Generic Contaminant Concentration | |
1 | No | N/A |
Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
1 | No | N/A | N/A | N/A |
Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
1 | RegulaFalsi |
Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
1 | 0.330 | 460.000 | 6.500000E-003 |
Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
1 | 0 | 0 | 0 |
Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
1 | 18 | 167 | 24 |
Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
1 | CORE_BOTTOM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 1.37 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 0.00 | 2.74 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
2 | TOPFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 11.28 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 10.67 | 11.89 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 10 | 0 | 0 | No |
3 | MIDFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 7.32 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 6.71 | 7.92 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
4 | FIRSTFLOOR_PLENUM | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 3.35 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 33.27 | 2.74 | 3.96 | 1.22 | 2024.76 | TARP | TARP | 1660.73 | 202.84 | 202.84 | 0.00 | 14 | 0 | 0 | No |
5 | CORE_MID | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 5.33 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 3.96 | 6.71 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
6 | CORE_TOP | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 16.64 | 9.30 | 1 | 1 | 1 | 4.57 | 45.34 | 4.57 | 28.70 | 7.92 | 10.67 | 2.74 | 2698.04 | TARP | TARP | 983.54 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
7 | PERIMETER_TOP_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
8 | PERIMETER_TOP_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 9.30 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
9 | PERIMETER_TOP_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 9.30 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 7.92 | 10.67 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
10 | PERIMETER_TOP_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 9.30 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 7.92 | 10.67 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
11 | PERIMETER_BOT_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 67.75 | 65.26 | 6 | 5 | 0 | Yes |
12 | PERIMETER_BOT_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 1.37 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 45.82 | 43.51 | 6 | 3 | 0 | Yes |
13 | PERIMETER_BOT_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 1.37 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 0.00 | 2.74 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 67.75 | 65.26 | 6 | 5 | 0 | Yes |
14 | PERIMETER_BOT_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 1.37 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 0.00 | 2.74 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 45.82 | 43.51 | 6 | 3 | 0 | Yes |
15 | PERIMETER_MID_ZN_3 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 31.11 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 28.70 | 33.27 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
16 | PERIMETER_MID_ZN_2 | 0.0 | 0.00 | 0.00 | 0.00 | 47.82 | 16.64 | 5.33 | 1 | 1 | 1 | 45.34 | 49.91 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.08 | TARP | TARP | 131.26 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
17 | PERIMETER_MID_ZN_1 | 0.0 | 0.00 | 0.00 | 0.00 | 24.96 | 2.16 | 5.33 | 1 | 1 | 1 | 0.00 | 49.91 | 0.00 | 4.57 | 3.96 | 6.71 | 2.74 | 568.77 | TARP | TARP | 207.34 | 136.92 | 71.65 | 65.26 | 6 | 1 | 0 | Yes |
18 | PERIMETER_MID_ZN_4 | 0.0 | 0.00 | 0.00 | 0.00 | 2.09 | 16.64 | 5.33 | 1 | 1 | 1 | 0.00 | 4.57 | 0.00 | 33.27 | 3.96 | 6.71 | 2.74 | 360.05 | TARP | TARP | 131.25 | 91.28 | 47.77 | 43.51 | 6 | 1 | 0 | Yes |
Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
1 | CORE_BOTTOM | 983.54 | 52.9 | 18.579 | 5.382E-002 | 6.664 | 24.834 | 0.000 | 0.000 | 0.000 | 0.000 | 31.498 | No |
2 | TOPFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
3 | MIDFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
4 | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
5 | CORE_MID | 983.54 | 52.9 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
6 | CORE_TOP | 983.54 | 52.9 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
7 | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
8 | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 6.664 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.733 | No |
9 | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
10 | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
11 | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
12 | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 6.664 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.733 | No |
13 | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
14 | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
15 | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
16 | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 18.579 | 5.382E-002 | 6.664 | 8.069 | 0.000 | 0.000 | 0.000 | 0.000 | 14.733 | No |
17 | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
18 | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 18.579 | 5.382E-002 | 6.664 | 8.070 | 0.000 | 0.000 | 0.000 | 0.000 | 14.734 | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | MRT Calculation Type | Work Efficiency | Clothing Insulation Calculation Method | Clothing Insulation Calculation Method Schedule | Clothing | Air Velocity | Fanger Calculation | Pierce Calculation | KSU Calculation | Cooling Effect Calculation | Ankle Draft Calculation | |
1 | CORE_BOTTOM | BLDG_OCC_SCH_WO_SB | CORE_BOTTOM | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
2 | CORE_MID | BLDG_OCC_SCH_WO_SB | CORE_MID | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
3 | CORE_TOP | BLDG_OCC_SCH_WO_SB | CORE_TOP | 983.54 | 52.9 | 52.9 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 53 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
4 | PERIMETER_TOP_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
5 | PERIMETER_TOP_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
6 | PERIMETER_TOP_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
7 | PERIMETER_TOP_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
8 | PERIMETER_BOT_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
9 | PERIMETER_BOT_ZN_2 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
10 | PERIMETER_BOT_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
11 | PERIMETER_BOT_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
12 | PERIMETER_MID_ZN_3 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
13 | PERIMETER_MID_ZN_2 | BLDG_OCC_SCH_W_SB | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
14 | PERIMETER_MID_ZN_1 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 11.2 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
15 | PERIMETER_MID_ZN_4 | BLDG_OCC_SCH_WO_SB | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 7.1 | 5.382E-002 | 18.579 | 0.300 | 0.700 | AutoCalculate | ACTIVITY_SCH | No | 3.8200E-008 | 0 | 7 | Zone Averaged | WORK_EFF_SCH | Clothing Insulation Schedule | N/A | CLOTHING_SCH | AIR_VELO_SCH | Yes | No | No | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
1 | CORE_BOTTOM_LIGHTS | LTG_SCH_OFFICE | CORE_BOTTOM | 983.54 | 52.9 | 6553.914 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6553.914 |
2 | CORE_MID_LIGHTS | LTG_SCH_OFFICE | CORE_MID | 983.54 | 52.9 | 6553.914 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6553.914 |
3 | CORE_TOP_LIGHTS | LTG_SCH_OFFICE | CORE_TOP | 983.54 | 52.9 | 6553.914 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 6553.914 |
4 | PERIMETER_TOP_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1381.623 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1381.623 |
5 | PERIMETER_TOP_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 874.681 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 874.681 |
6 | PERIMETER_TOP_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1381.623 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1381.623 |
7 | PERIMETER_TOP_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 874.624 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 874.624 |
8 | PERIMETER_BOT_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1381.623 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1381.623 |
9 | PERIMETER_BOT_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 874.681 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 874.681 |
10 | PERIMETER_BOT_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1381.623 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1381.623 |
11 | PERIMETER_BOT_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 874.624 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 874.624 |
12 | PERIMETER_MID_ZN_3_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1381.623 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1381.623 |
13 | PERIMETER_MID_ZN_2_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 874.681 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 874.681 |
14 | PERIMETER_MID_ZN_1_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1381.623 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 1381.623 |
15 | PERIMETER_MID_ZN_4_LIGHTS | LTG_SCH_OFFICE | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 874.624 | 6.664 | 123.802 | 0.000 | 0.700 | 0.200 | 0.100 | 1.000 | LightsWired | 0.000 | 874.624 |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
1 | CORE_BOTTOM_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_BOTTOM | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
2 | CORE_MID_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_MID | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
3 | CORE_TOP_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | CORE_TOP | 983.54 | 52.9 | 7937.156 | 8.070 | 149.931 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 7937.156 |
4 | PERIMETER_TOP_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
5 | PERIMETER_TOP_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
6 | PERIMETER_TOP_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
7 | PERIMETER_TOP_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
8 | PERIMETER_BOT_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
9 | PERIMETER_BOT_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
10 | PERIMETER_BOT_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
11 | PERIMETER_BOT_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
12 | PERIMETER_MID_ZN_3_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 1673.214 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.214 |
13 | PERIMETER_MID_ZN_2_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 1059.217 | 8.069 | 149.921 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.217 |
14 | PERIMETER_MID_ZN_1_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 1673.203 | 8.070 | 149.929 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1673.203 |
15 | PERIMETER_MID_ZN_4_MISCPLUG_EQUIP | BLDG_EQUIP_SCH | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 1059.210 | 8.070 | 149.930 | 0.000 | 0.500 | 0.000 | 0.500 | MiscPlug | 0.000 | 1059.210 |
16 | CORE_BOTTOM_ELEVATORS_EQUIP | BLDG_ELEVATORS | CORE_BOTTOM | 983.54 | 52.9 | 16363.220 | 16.637 | 309.098 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLift | 1963.586 | 11290.622 |
17 | ELEVATORS_LIGHTS_FAN | ELEV_LIGHT_FAN_SCH_ADD_DF | CORE_BOTTOM | 983.54 | 52.9 | 125.000 | 0.127 | 2.361 | 0.000 | 0.500 | 0.000 | 0.500 | ElevatorLightsFan | 0.000 | 86.250 |
Construction Name | Index | #Layers | #CTFs | Time Step {hours} | ThermalConductance {w/m2-K} | OuterThermalAbsorptance | InnerThermalAbsorptance | OuterSolarAbsorptance | InnerSolarAbsorptance | Roughness | |
1 | SWINGING DOOR_CON | 1 | 1 | 1 | 0.167 | 2.101 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
2 | INTERIORFURNISHINGS | 2 | 1 | 9 | 0.167 | 0.8000 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
3 | DROPCEILING | 4 | 1 | 3 | 0.167 | 4.488 | 0.900 | 0.900 | 0.700 | 0.700 | MediumSmooth |
4 | INT_WALL | 7 | 2 | 4 | 0.167 | 6.299 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
5 | INT_SLAB_FLOOR | 12 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | MediumRough |
6 | INT_SLAB_CEILING | 13 | 2 | 7 | 0.167 | 3.839 | 0.900 | 0.900 | 0.700 | 0.700 | VeryRough |
7 | NONRES_ROOF | 17 | 3 | 3 | 0.167 | 0.1864 | 0.900 | 0.900 | 0.700 | 0.700 | Rough |
8 | NONRES_EXT_WALL_GRD | 20 | 4 | 7 | 0.167 | 0.8022 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
9 | NONRES_EXT_WALL_MID | 21 | 4 | 7 | 0.167 | 0.7887 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
10 | NONRES_EXT_WALL_TOP | 22 | 4 | 7 | 0.167 | 1.032 | 0.900 | 0.900 | 0.700 | 0.700 | Smooth |
11 | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 39 | 2 | 7 | 0.167 | 0.2242 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
12 | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 40 | 2 | 7 | 0.167 | 0.2365 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
13 | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 41 | 2 | 7 | 0.167 | 0.2242 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
14 | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 42 | 2 | 7 | 0.167 | 0.2366 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
15 | CORE_BOT_ZN_5_FLOOR_FFACTOR | 43 | 2 | 8 | 0.167 | 0.5650E-02 | 0.000 | 0.900 | 0.000 | 0.700 | MediumRough |
Material Name | Thickness {m} | Conductivity {w/m-K} | Density {kg/m3} | Specific Heat {J/kg-K} | ThermalResistance {m2-K/w} | |
1 | OPAQUE DOOR PANEL_CON | 0.0000 | 0.000 | 0.000 | 0.000 | 0.4760 |
2 | STD WOOD 6INCH | 0.1500 | 0.120 | 540.000 | 1210.000 | 1.250 |
3 | AC02 ACOUSTIC CEILING | 0.0127 | 0.057 | 288.000 | 1339.000 | 0.2228 |
4 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
5 | G01 13MM GYPSUM BOARD | 0.0127 | 0.160 | 800.000 | 1090.000 | 0.7937E-01 |
6 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
7 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
8 | CP02 CARPET PAD | 0.0000 | 0.000 | 0.000 | 0.000 | 0.2165 |
9 | 100MM NORMALWEIGHT CONCRETE FLOOR | 0.1016 | 2.310 | 2322.000 | 832.000 | 0.4398E-01 |
10 | F13 BUILT-UP ROOFING | 0.0095 | 0.160 | 1120.000 | 1460.000 | 0.5938E-01 |
11 | NONRES_ROOF_INSULATION | 0.0000 | 0.000 | 0.000 | 0.000 | 5.307 |
12 | F08 METAL SURFACE | 0.0008 | 45.280 | 7824.000 | 500.000 | 0.1767E-04 |
13 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
14 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
15 | NONRES_EXTERIOR_WALL_INSULATION_GRD | 0.0000 | 0.000 | 0.000 | 0.000 | 1.013 |
16 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
17 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
18 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
19 | NONRES_EXTERIOR_WALL_INSULATION_MID | 0.0000 | 0.000 | 0.000 | 0.000 | 1.034 |
20 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
21 | F07 25MM STUCCO | 0.0254 | 0.720 | 1856.000 | 840.000 | 0.3528E-01 |
22 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
23 | NONRES_EXTERIOR_WALL_INSULATION_TOP | 0.0000 | 0.000 | 0.000 | 0.000 | 0.7350 |
24 | G01 16MM GYPSUM BOARD | 0.0159 | 0.160 | 800.000 | 1090.000 | 0.9938E-01 |
25 | ~FC_Insulation_1 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.383 |
26 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
27 | ~FC_Insulation_2 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.151 |
28 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
29 | ~FC_Insulation_3 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.383 |
30 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
31 | ~FC_Insulation_4 | 0.0000 | 0.000 | 0.000 | 0.000 | 4.150 |
32 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
33 | ~FC_Insulation_5 | 0.0000 | 0.000 | 0.000 | 0.000 | 176.9 |
34 | ~FC_Concrete | 0.1500 | 1.950 | 2240.000 | 900.000 | 0.7692E-01 |
Time | Outside | Cross | Inside | Flux (except final one) | |
1 | 1 | 0.0000000 | 0.0000000 | -0.0000000 | -0.0000000 |
2 | 0 | 2.1009573 | 2.1009573 | 2.1009573 | |
3 | 9 | -0.27580628E-02 | 0.97439125E-12 | -0.27580628E-02 | 0.28516790E-03 |
4 | 8 | 0.73590997E-01 | 0.21837543E-08 | 0.73590997E-01 | -0.77836043E-02 |
5 | 7 | -0.82599318 | 0.23162835E-06 | -0.82599318 | 0.89703933E-01 |
6 | 6 | 5.1113916 | 0.48671053E-05 | 5.1113916 | -0.57224845 |
7 | 5 | -19.214933 | 0.30163627E-04 | -19.214933 | 2.2266322 |
8 | 4 | 45.557404 | 0.63181060E-04 | 45.557404 | -5.4853312 |
9 | 3 | -68.275533 | 0.44785456E-04 | -68.275533 | 8.5710568 |
10 | 2 | 62.555368 | 0.93952058E-05 | 62.555368 | -8.2111738 |
11 | 1 | -31.904423 | 0.39200004E-06 | -31.904423 | 4.3886678 |
12 | 0 | 6.9260389 | 0.77047546E-09 | 6.9260389 | |
13 | 3 | -0.21589802E-09 | 0.15643069E-09 | -0.21589802E-09 | 0.12999471E-21 |
14 | 2 | 0.50772448E-02 | 0.30006816E-02 | 0.50772448E-02 | -0.13693132E-08 |
15 | 1 | -2.5944910 | 1.4597758 | -2.5944910 | 0.76344767E-02 |
16 | 0 | 7.0433378 | 2.9911476 | 7.0433378 | |
17 | 4 | 0.68458728E-09 | 0.26079551E-09 | 0.68458728E-09 | -0.34507121E-18 |
18 | 3 | -0.72180374E-03 | 0.24295686E-03 | -0.72180374E-03 | 0.69691454E-09 |
19 | 2 | 0.83054762 | 0.27682775 | 0.83054762 | -0.35168967E-03 |
20 | 1 | -12.650482 | 3.3590720 | -12.650482 | 0.19281313 |
21 | 0 | 16.907513 | 1.4507143 | 16.907513 | |
22 | 7 | 0.43260499E-16 | 0.34524919E-16 | 0.52793240E-17 | 0.0000000 |
23 | 6 | 0.69434179E-09 | 0.98085174E-11 | 0.18162501E-10 | -0.40870994E-12 |
24 | 5 | -0.12888762E-04 | 0.28373718E-06 | -0.16918523E-06 | 0.92361873E-08 |
25 | 4 | 0.25174112E-01 | 0.33697681E-03 | 0.22646198E-03 | -0.31467795E-04 |
26 | 3 | -3.7600775 | 0.27170599E-01 | -0.48495626E-01 | 0.94171705E-02 |
27 | 2 | 51.553741 | 0.22121684 | 1.2284947 | -0.25833933 |
28 | 1 | -128.86110 | 0.21944682 | -5.1479470 | 1.1228340 |
29 | 0 | 81.526494 | 0.16043334E-01 | 4.4519351 | |
30 | 7 | 0.52793240E-17 | 0.34524919E-16 | 0.43260499E-16 | 0.0000000 |
31 | 6 | 0.18162501E-10 | 0.98085174E-11 | 0.69434179E-09 | -0.40870994E-12 |
32 | 5 | -0.16918523E-06 | 0.28373718E-06 | -0.12888762E-04 | 0.92361873E-08 |
33 | 4 | 0.22646198E-03 | 0.33697681E-03 | 0.25174112E-01 | -0.31467795E-04 |
34 | 3 | -0.48495626E-01 | 0.27170599E-01 | -3.7600775 | 0.94171705E-02 |
35 | 2 | 1.2284947 | 0.22121684 | 51.553741 | -0.25833933 |
36 | 1 | -5.1479470 | 0.21944682 | -128.86110 | 1.1228340 |
37 | 0 | 4.4519351 | 0.16043334E-01 | 81.526494 | |
38 | 3 | -0.62854340E-06 | 0.84784826E-09 | -0.38512804E-05 | 0.91756347E-17 |
39 | 2 | 0.78257096 | 0.11428808E-02 | 1.0614277 | -0.73836085E-06 |
40 | 1 | -21.991499 | 0.76199851E-01 | -6.3161914 | 0.20349372 |
41 | 0 | 21.357363 | 0.71091016E-01 | 5.4032014 | |
42 | 7 | -0.29755900E-12 | 0.81313074E-15 | -0.93602003E-13 | 0.14510957E-15 |
43 | 6 | 0.28367368E-07 | 0.22496401E-09 | 0.65009128E-08 | -0.13359594E-12 |
44 | 5 | -0.18856357E-03 | 0.19286971E-05 | -0.97009749E-04 | 0.64274374E-08 |
45 | 4 | 0.29034011 | 0.94012602E-03 | 0.99033658E-01 | -0.33316087E-04 |
46 | 3 | -7.2305496 | 0.29163423E-01 | -2.3282961 | 0.28833673E-01 |
47 | 2 | 40.753148 | 0.10379063 | 15.221555 | -0.33202618 |
48 | 1 | -80.455373 | 0.46876469E-01 | -29.102648 | 1.0766925 |
49 | 0 | 46.824339 | 0.94379271E-03 | 16.292168 | |
50 | 7 | -0.29905644E-12 | 0.21441847E-14 | -0.94350753E-13 | 0.15229914E-15 |
51 | 6 | 0.28527035E-07 | 0.22156944E-09 | 0.65361533E-08 | -0.13441220E-12 |
52 | 5 | -0.18937502E-03 | 0.18976302E-05 | -0.97416439E-04 | 0.64617957E-08 |
53 | 4 | 0.29129073 | 0.92413897E-03 | 0.99375489E-01 | -0.33450099E-04 |
54 | 3 | -7.2493786 | 0.28644335E-01 | -2.3338831 | 0.28925940E-01 |
55 | 2 | 40.815249 | 0.10187053 | 15.244478 | -0.33271782 |
56 | 1 | -80.502964 | 0.45980673E-01 | -29.123201 | 1.0777067 |
57 | 0 | 46.824339 | 0.92519179E-03 | 16.291675 | |
58 | 7 | -0.27570686E-12 | 0.13707328E-14 | -0.80264236E-13 | 0.78378346E-16 |
59 | 6 | 0.25615968E-07 | 0.28022365E-09 | 0.58936169E-08 | -0.11887149E-12 |
60 | 5 | -0.17446821E-03 | 0.24481169E-05 | -0.89927666E-04 | 0.58344893E-08 |
61 | 4 | 0.27366067 | 0.12133616E-02 | 0.93044102E-01 | -0.30982017E-04 |
62 | 3 | -6.8997845 | 0.38197916E-01 | -2.2301787 | 0.27213971E-01 |
63 | 2 | 39.661773 | 0.13771433 | 14.818013 | -0.31987377 |
64 | 1 | -79.618511 | 0.62899977E-01 | -28.740542 | 1.0588596 |
65 | 0 | 46.824345 | 0.12804488E-02 | 16.301062 | |
66 | 7 | -0.18778705E-08 | -0.48456698E-15 | 0.68415356E-14 | -0.90766841E-16 |
67 | 6 | 0.62832840E-05 | 0.42957215E-08 | 0.31879255E-02 | -0.26742991E-04 |
68 | 5 | -0.45150393E-03 | 0.25448514E-05 | -0.22361406 | 0.19551748E-02 |
69 | 4 | 0.10383635E-01 | 0.11583744E-03 | 4.8277051 | -0.45247288E-01 |
70 | 3 | -0.91177470E-01 | 0.92119394E-03 | -38.011019 | 0.39853883 |
71 | 2 | 0.32374524 | 0.15324382E-02 | 116.46371 | -1.4176686 |
72 | 1 | -0.46727348 | 0.46697369E-03 | -143.89540 | 2.0488441 |
73 | 0 | 0.22781756 | 0.11275910E-04 | 60.838472 | |
74 | 7 | -0.17777358E-08 | -0.41207670E-15 | 0.60771148E-14 | -0.79247013E-16 |
75 | 6 | 0.66205355E-05 | 0.45347915E-08 | 0.31869553E-02 | -0.26734852E-04 |
76 | 5 | -0.47643654E-03 | 0.26865296E-05 | -0.22355891 | 0.19546881E-02 |
77 | 4 | 0.10961386E-01 | 0.12229770E-03 | 4.8267865 | -0.45238458E-01 |
78 | 3 | -0.96263561E-01 | 0.97262436E-03 | -38.005829 | 0.39848146 |
79 | 2 | 0.34182167 | 0.16181264E-02 | 116.45361 | -1.4175335 |
80 | 1 | -0.49337445 | 0.49308431E-03 | -143.88945 | 2.0487464 |
81 | 0 | 0.24054552 | 0.11921404E-04 | 60.838472 | |
82 | 7 | -0.18778705E-08 | -0.48456747E-15 | 0.68415356E-14 | -0.90766840E-16 |
83 | 6 | 0.62832840E-05 | 0.42957215E-08 | 0.31879255E-02 | -0.26742991E-04 |
84 | 5 | -0.45150393E-03 | 0.25448514E-05 | -0.22361406 | 0.19551748E-02 |
85 | 4 | 0.10383635E-01 | 0.11583744E-03 | 4.8277051 | -0.45247288E-01 |
86 | 3 | -0.91177470E-01 | 0.92119394E-03 | -38.011019 | 0.39853883 |
87 | 2 | 0.32374524 | 0.15324382E-02 | 116.46371 | -1.4176686 |
88 | 1 | -0.46727348 | 0.46697369E-03 | -143.89540 | 2.0488441 |
89 | 0 | 0.22781756 | 0.11275910E-04 | 60.838472 | |
90 | 7 | -0.17776120E-08 | -0.41258204E-15 | 0.60425363E-14 | -0.82023253E-16 |
91 | 6 | 0.66209765E-05 | 0.45351028E-08 | 0.31869540E-02 | -0.26734841E-04 |
92 | 5 | -0.47646911E-03 | 0.26867147E-05 | -0.22355884 | 0.19546874E-02 |
93 | 4 | 0.10962140E-01 | 0.12230614E-03 | 4.8267853 | -0.45238446E-01 |
94 | 3 | -0.96270204E-01 | 0.97269154E-03 | -38.005822 | 0.39848139 |
95 | 2 | 0.34184528 | 0.16182383E-02 | 116.45360 | -1.4175333 |
96 | 1 | -0.49340854 | 0.49311848E-03 | -143.88944 | 2.0487463 |
97 | 0 | 0.24056214 | 0.11922214E-04 | 60.838472 | |
98 | 8 | 0.57026216E-10 | -0.29656739E-13 | 0.26072253E-13 | -0.16907584E-15 |
99 | 7 | -0.80728763E-07 | 0.14958947E-11 | -0.10196182E-04 | 0.85534123E-07 |
100 | 6 | 0.59163330E-05 | 0.23390251E-08 | 0.39199948E-02 | -0.33137873E-04 |
101 | 5 | -0.14678961E-03 | 0.29443049E-06 | -0.24001665 | 0.21083805E-02 |
102 | 4 | 0.15257864E-02 | 0.63469284E-05 | 4.9653291 | -0.46676227E-01 |
103 | 3 | -0.74362311E-02 | 0.30151767E-04 | -38.474208 | 0.40407555 |
104 | 2 | 0.17883035E-01 | 0.32406056E-04 | 117.10039 | -1.4265819 |
105 | 1 | -0.20235698E-01 | 0.62001922E-05 | -144.19380 | 2.0537490 |
106 | 0 | 0.84795330E-02 | 0.69040512E-07 | 60.838472 |
Construction Name | Index | #Layers | Roughness | Conductance {W/m2-K} | Conductance (Before Adjusted) {W/m2-K} | Convection Coefficient Adjustment Ratio | SHGC | Solar Transmittance at Normal Incidence | Visible Transmittance at Normal Incidence | |
1 | WINDOW_U_0.363_SHGC_EAST_0.378 | 35 | 1 | VerySmooth | 2.062 | 2.062 | 1.000 | 0.379 | ||
2 | WINDOW_U_0.363_SHGC_SOUTH_0.378 | 36 | 1 | VerySmooth | 2.062 | 2.062 | 1.000 | 0.379 | ||
3 | WINDOW_U_0.363_SHGC_WEST_0.378 | 37 | 1 | VerySmooth | 2.062 | 2.062 | 1.000 | 0.379 | ||
4 | WINDOW_U_0.363_SHGC_NORTH_0.378 | 38 | 1 | VerySmooth | 2.062 | 2.062 | 1.000 | 0.379 |
Material Name | Optical Data Type | Spectral Data Set Name | Thickness {m} | Solar Transmittance | Front Solar Reflectance | Back Solar Reflectance | Visible Transmittance | Front Visible Reflectance | Back Visible Reflectance | Infrared Transmittance | Front Thermal Emissivity | Back Thermal Emissivity | Conductivity {W/m-K} | Dirt Factor | Solar Diffusing | |
1 | GLAZING LAYER EAST | SpectralAverage | 3.62716E-002 | 0.29167 | 0.50232 | 0.50232 | 0.41580 | 0.13603 | 0.17565 | 0.00000 | 0.84000 | 0.84000 | 0.11617 | 1.00000 | No | |
2 | GLAZING LAYER SOUTH | SpectralAverage | 3.62716E-002 | 0.29167 | 0.50232 | 0.50232 | 0.41580 | 0.13603 | 0.17565 | 0.00000 | 0.84000 | 0.84000 | 0.11617 | 1.00000 | No | |
3 | GLAZING LAYER WEST | SpectralAverage | 3.62716E-002 | 0.29167 | 0.50232 | 0.50232 | 0.41580 | 0.13603 | 0.17565 | 0.00000 | 0.84000 | 0.84000 | 0.11617 | 1.00000 | No | |
4 | GLAZING LAYER NORTH | SpectralAverage | 3.62716E-002 | 0.29167 | 0.50232 | 0.50232 | 0.41580 | 0.13603 | 0.17565 | 0.00000 | 0.84000 | 0.84000 | 0.11617 | 1.00000 | No |
Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
1 | PolygonClipping | Periodic | 30 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
1 | PERIMETER_TOP_ZN_3 | 1 | 0 |
2 | PERIMETER_TOP_ZN_2 | 1 | 0 |
3 | PERIMETER_TOP_ZN_1 | 1 | 0 |
4 | PERIMETER_TOP_ZN_4 | 1 | 0 |
5 | PERIMETER_BOT_ZN_3 | 3 | 0 |
6 | PERIMETER_BOT_ZN_2 | 2 | 0 |
7 | PERIMETER_BOT_ZN_1 | 3 | 0 |
8 | PERIMETER_BOT_ZN_4 | 2 | 0 |
9 | PERIMETER_MID_ZN_3 | 1 | 0 |
10 | PERIMETER_MID_ZN_2 | 1 | 0 |
11 | PERIMETER_MID_ZN_1 | 1 | 0 |
12 | PERIMETER_MID_ZN_4 | 1 | 0 |
Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
1 | PERIMETER_TOP_ZN_3 | 0 | |
2 | PERIMETER_TOP_ZN_2 | 0 | |
3 | PERIMETER_TOP_ZN_1 | 0 | |
4 | PERIMETER_TOP_ZN_4 | 0 | |
5 | PERIMETER_BOT_ZN_3 | 0 | |
6 | PERIMETER_BOT_ZN_2 | 0 | |
7 | PERIMETER_BOT_ZN_1 | 0 | |
8 | PERIMETER_BOT_ZN_4 | 0 | |
9 | PERIMETER_MID_ZN_3 | 0 | |
10 | PERIMETER_MID_ZN_2 | 0 | |
11 | PERIMETER_MID_ZN_1 | 0 | |
12 | PERIMETER_MID_ZN_4 | 0 |
Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
1 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | 0.3785 | 29307.1 | 0.980 | 0.1802 |
Surface Name | Outside Model Assignment | Outside Area [m2] | Outside Perimeter [m] | Outside Height [m] | Inside Model Assignment | Inside Height [m] | Inside Perimeter Envelope [m] | Inside Hydraulic Diameter [m] | Window Wall Ratio | Window Location | Near Radiant {Yes/No} | Has Active HVAC {Yes/No} | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
2 | CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
3 | CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
4 | CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
5 | CORE_BOT_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
6 | CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
7 | CORE_BOTTOM_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
9 | PERIMETER_TOP_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
11 | PERIMETER_TOP_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
12 | iz-PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
13 | iz-PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
14 | iz-PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
15 | iz-PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
16 | iz-CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
17 | BUILDING_ROOF | 0 | 1660.73 | 183.01 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
18 | PERIMETER_MID_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
19 | PERIMETER_MID_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
21 | PERIMETER_MID_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
22 | iz-PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
23 | iz-PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
24 | iz-PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
25 | iz-PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
26 | iz-CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
31 | iz-CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
33 | PERIMETER_BOT_PLENUM_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
35 | PERIMETER_BOT_PLENUM_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
36 | iz-PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
37 | iz-PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
38 | iz-PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
39 | iz-PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
40 | iz-CORE_BOT_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
41 | iz-PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
42 | iz-PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
43 | iz-PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
44 | iz-PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
45 | iz-CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 1.22 | 166.37 | 39.93 | 0.00 | 0 | No | No |
46 | CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
47 | CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
48 | CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
49 | CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
50 | CORE_MID_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
51 | CORE_MID_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
52 | CORE_MID_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
53 | CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
54 | CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
55 | CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
56 | CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
57 | CORE_TOP_ZN_5_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
58 | CORE_TOP_ZN_5_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
59 | CORE_TOP_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 0.00 | 30.31 | -999.00 | 0 | No | No |
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
65 | PERIMETER_TOP_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
66 | PERIMETER_TOP_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
68 | PERIMETER_TOP_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
72 | iz-CORE_TOP_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
73 | PERIMETER_TOP_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
74 | PERIMETER_TOP_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
81 | PERIMETER_TOP_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
82 | PERIMETER_TOP_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
84 | PERIMETER_TOP_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
88 | iz-CORE_TOP_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
89 | PERIMETER_TOP_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
90 | PERIMETER_TOP_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
101 | PERIMETER_BOT_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
102 | PERIMETER_BOT_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
104 | PERIMETER_BOT_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
110 | iz-CORE_BOT_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
111 | PERIMETER_BOT_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
112 | PERIMETER_BOT_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
123 | PERIMETER_BOT_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
124 | PERIMETER_BOT_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
126 | PERIMETER_BOT_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
132 | iz-CORE_BOT_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
133 | PERIMETER_BOT_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
134 | PERIMETER_BOT_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
136 | PERIMETER_MID_ZN_3_WALL_NORTH | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0 | 593.30 | 143.75 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
138 | PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
140 | iz-CORE_MID_ZN_5_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
141 | PERIMETER_MID_ZN_3_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
142 | PERIMETER_MID_ZN_3_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
144 | PERIMETER_MID_ZN_2_WALL_EAST | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 0 | 395.53 | 143.75 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
148 | iz-CORE_MID_ZN_5_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
149 | PERIMETER_MID_ZN_2_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
150 | PERIMETER_MID_ZN_2_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 3 | No | No |
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 0 | 593.30 | 123.60 | 11.89 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 2 | No | No |
154 | PERIMETER_MID_ZN_1_WALL_EAST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
157 | PERIMETER_MID_ZN_1_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
158 | PERIMETER_MID_ZN_1_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 49.91 | 7.61 | 0.48 | 0 | No | No |
160 | PERIMETER_MID_ZN_4_WALL_WEST | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 3 | No | No |
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0 | 395.53 | 90.32 | 11.89 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 2 | No | No |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
164 | iz-CORE_MID_ZN_5_WALL_WEST | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
165 | PERIMETER_MID_ZN_4_FLOOR | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
166 | PERIMETER_MID_ZN_4_CEILING | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | 0 | 0.00 | 0.00 | 0.00 | 0 | 2.74 | 33.27 | 6.94 | 0.48 | 0 | No | No |
Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
1 | PERIMETER_TOP_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_3 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
2 | PERIMETER_TOP_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_2 | 131.26 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
3 | PERIMETER_TOP_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_1 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
4 | PERIMETER_TOP_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_TOP_ZN_4 | 131.25 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
5 | PERIMETER_BOT_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_3 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.538E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
6 | PERIMETER_BOT_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_2 | 131.26 | 7.1 | 5.199E-002 | 3.961E-004 | 5.577E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
7 | PERIMETER_BOT_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.538E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
8 | PERIMETER_BOT_ZN_1_DOOR_INFILTRATION | INFIL_DOOR_OPENING_SCH | PERIMETER_BOT_ZN_1 | 207.34 | 11.2 | 0.679 | 3.273E-003 | 4.819E-003 | 4.296 | 1.000 | 0.000 | 0.000 | 0.000 |
9 | PERIMETER_BOT_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_BOT_ZN_4 | 131.25 | 7.1 | 5.199E-002 | 3.961E-004 | 5.577E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
10 | PERIMETER_MID_ZN_3_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_3 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
11 | PERIMETER_MID_ZN_2_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_2 | 131.26 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
12 | PERIMETER_MID_ZN_1_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_1 | 207.34 | 11.2 | 7.798E-002 | 3.761E-004 | 5.696E-004 | 0.494 | 0.000 | 0.000 | 0.224 | 0.000 |
13 | PERIMETER_MID_ZN_4_INFILTRATION | INFIL_SCH_PNNL | PERIMETER_MID_ZN_4 | 131.25 | 7.1 | 5.199E-002 | 3.961E-004 | 5.696E-004 | 0.520 | 0.000 | 0.000 | 0.224 | 0.000 |
14 | FIRSTFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | FIRSTFLOOR_PLENUM | 1660.73 | 0.0 | 0.116 | 6.957E-005 | 5.696E-004 | 0.205 | 0.000 | 0.000 | 0.224 | 0.000 |
15 | MIDFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | MIDFLOOR_PLENUM | 1660.73 | 0.0 | 0.116 | 6.957E-005 | 5.696E-004 | 0.205 | 0.000 | 0.000 | 0.224 | 0.000 |
16 | TOPFLOOR_PLENUM_INFILTRATION | INFIL_SCH_PNNL | TOPFLOOR_PLENUM | 1660.73 | 0.0 | 0.116 | 6.957E-005 | 6.199E-005 | 0.205 | 0.000 | 0.000 | 0.224 | 0.000 |
Simple | |
1 | Simple |
Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
1 | CORE_BOTTOM | Mixing/Well-Stirred |
2 | TOPFLOOR_PLENUM | Mixing/Well-Stirred |
3 | MIDFLOOR_PLENUM | Mixing/Well-Stirred |
4 | FIRSTFLOOR_PLENUM | Mixing/Well-Stirred |
5 | CORE_MID | Mixing/Well-Stirred |
6 | CORE_TOP | Mixing/Well-Stirred |
7 | PERIMETER_TOP_ZN_3 | Mixing/Well-Stirred |
8 | PERIMETER_TOP_ZN_2 | Mixing/Well-Stirred |
9 | PERIMETER_TOP_ZN_1 | Mixing/Well-Stirred |
10 | PERIMETER_TOP_ZN_4 | Mixing/Well-Stirred |
11 | PERIMETER_BOT_ZN_3 | Mixing/Well-Stirred |
12 | PERIMETER_BOT_ZN_2 | Mixing/Well-Stirred |
13 | PERIMETER_BOT_ZN_1 | Mixing/Well-Stirred |
14 | PERIMETER_BOT_ZN_4 | Mixing/Well-Stirred |
15 | PERIMETER_MID_ZN_3 | Mixing/Well-Stirred |
16 | PERIMETER_MID_ZN_2 | Mixing/Well-Stirred |
17 | PERIMETER_MID_ZN_1 | Mixing/Well-Stirred |
18 | PERIMETER_MID_ZN_4 | Mixing/Well-Stirred |
No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
1 | NoMultizoneOrDistribution |
Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
1 | 1.000 | 1.000 | 1.000 | 1.000 |
Value | |
1 | 6 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sizing Factor ID | Value | |
1 | Global | 1.0000 |
Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
1 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.2115E-002 |
2 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.2185E-002 |
3 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.3381E-002 |
4 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.3442E-002 |
5 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.2296E-003 |
6 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.2785E-003 |
7 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.3510E-003 |
8 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.3752E-003 |
9 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1673 |
10 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.9797E-002 |
11 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1898 |
12 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 0.1018 |
13 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 0.1171 |
14 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.9932E-002 |
15 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.8073E-002 |
16 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.8035E-002 |
17 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.2114E-002 |
18 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.2182E-002 |
19 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 1.3379E-002 |
20 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 1.3439E-002 |
21 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 8.2287E-003 |
22 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 8.2767E-003 |
23 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT1 | 4.3507E-003 |
24 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_1_DAYLCTRL | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | PERIMETER_BOT_ZN_1_DAYLREFPT2 | 4.3749E-003 |
25 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.9676E-002 |
26 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 4.1014E-002 |
27 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.4146E-002 |
28 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.7166E-002 |
29 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.8760E-002 |
30 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 3.4795E-002 |
31 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.6444E-002 |
32 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 2.6601E-002 |
33 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 6.4127E-004 |
34 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 6.4391E-004 |
35 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.9814E-004 |
36 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 6.0004E-004 |
37 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.8688E-004 |
38 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.8752E-004 |
39 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT1 | 5.0780E-004 |
40 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_2_DAYLCTRL | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | PERIMETER_BOT_ZN_2_DAYLREFPT2 | 5.0864E-004 |
41 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.6216E-003 |
42 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.6789E-003 |
43 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.8576E-003 |
44 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.9030E-003 |
45 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.3633E-003 |
46 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.3952E-003 |
47 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.3507E-003 |
48 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.3749E-003 |
49 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.4064E-002 |
50 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 2.5257E-002 |
51 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.3885E-002 |
52 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.9215E-002 |
53 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.1342E-002 |
54 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.3231E-002 |
55 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.8073E-002 |
56 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 1.8035E-002 |
57 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.6219E-003 |
58 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.6792E-003 |
59 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.8579E-003 |
60 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.9035E-003 |
61 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 3.3638E-003 |
62 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 3.3963E-003 |
63 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT1 | 4.3510E-003 |
64 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_3_DAYLCTRL | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | PERIMETER_BOT_ZN_3_DAYLREFPT2 | 4.3752E-003 |
65 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 7.1305E-002 |
66 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 4.1788E-002 |
67 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.6184E-002 |
68 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.8137E-002 |
69 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 7.0092E-002 |
70 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 3.5415E-002 |
71 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.6444E-002 |
72 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 2.6601E-002 |
73 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.5398E-004 |
74 | Clear Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 6.6232E-004 |
75 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 6.1423E-004 |
76 | Clear Turbid Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 6.2355E-004 |
77 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.9599E-004 |
78 | Intermediate Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.9915E-004 |
79 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT1 | 5.0782E-004 |
80 | Overcast Sky | 12/21 | PERIMETER_BOT_ZN_4_DAYLCTRL | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | PERIMETER_BOT_ZN_4_DAYLREFPT2 | 5.0865E-004 |
81 | Clear Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1655 |
82 | Clear Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1068 |
83 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1844 |
84 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 0.1201 |
85 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 0.1252 |
86 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 6.3046E-002 |
87 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT1 | 5.4807E-002 |
88 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_1_DAYLCTRL | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_MID_ZN_1_DAYLREFPT2 | 2.5582E-002 |
89 | Clear Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 6.7376E-002 |
90 | Clear Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 3.9712E-002 |
91 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 6.2148E-002 |
92 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 3.6039E-002 |
93 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 6.7160E-002 |
94 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 3.3853E-002 |
95 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT1 | 5.5395E-002 |
96 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_2_DAYLCTRL | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | PERIMETER_MID_ZN_2_DAYLREFPT2 | 2.5971E-002 |
97 | Clear Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.0217E-002 |
98 | Clear Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 3.2920E-002 |
99 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.9352E-002 |
100 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.5798E-002 |
101 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 3.6825E-002 |
102 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 1.9276E-002 |
103 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT1 | 5.4807E-002 |
104 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_3_DAYLCTRL | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | PERIMETER_MID_ZN_3_DAYLREFPT2 | 2.5582E-002 |
105 | Clear Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.8959E-002 |
106 | Clear Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 4.0471E-002 |
107 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.4126E-002 |
108 | Clear Turbid Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.6992E-002 |
109 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 6.8457E-002 |
110 | Intermediate Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 3.4455E-002 |
111 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT1 | 5.5395E-002 |
112 | Overcast Sky | 12/21 | PERIMETER_MID_ZN_4_DAYLCTRL | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | PERIMETER_MID_ZN_4_DAYLREFPT2 | 2.5971E-002 |
113 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1655 |
114 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1068 |
115 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1844 |
116 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 0.1200 |
117 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 0.1252 |
118 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 6.3038E-002 |
119 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT1 | 5.4802E-002 |
120 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_1_DAYLCTRL | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | PERIMETER_TOP_ZN_1_DAYLREFPT2 | 2.5579E-002 |
121 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 6.7376E-002 |
122 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 3.9709E-002 |
123 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 6.2147E-002 |
124 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 3.6037E-002 |
125 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 6.7156E-002 |
126 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 3.3849E-002 |
127 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT1 | 5.5390E-002 |
128 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_2_DAYLCTRL | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | PERIMETER_TOP_ZN_2_DAYLREFPT2 | 2.5968E-002 |
129 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.0219E-002 |
130 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 3.2919E-002 |
131 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.9353E-002 |
132 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.5797E-002 |
133 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 3.6823E-002 |
134 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 1.9274E-002 |
135 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT1 | 5.4802E-002 |
136 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_3_DAYLCTRL | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | PERIMETER_TOP_ZN_3_DAYLREFPT2 | 2.5579E-002 |
137 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.8959E-002 |
138 | Clear Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 4.0468E-002 |
139 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.4125E-002 |
140 | Clear Turbid Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.6989E-002 |
141 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 6.8453E-002 |
142 | Intermediate Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 3.4451E-002 |
143 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT1 | 5.5390E-002 |
144 | Overcast Sky | 12/21 | PERIMETER_TOP_ZN_4_DAYLCTRL | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | PERIMETER_TOP_ZN_4_DAYLREFPT2 | 2.5968E-002 |
Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
1 | CORE_BOTTOM | Cooling | 38646.64755 | 38646.64755 | 3.43210 | 3.43210 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 22.94800 | 5.45871E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
2 | CORE_BOTTOM | Heating | 8524.37411 | 8524.37411 | 0.45027 | 0.45027 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:20:00 | -17.90000 | 9.55238E-004 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
3 | CORE_MID | Cooling | 28267.64965 | 28267.64965 | 2.50780 | 2.50780 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 22.94800 | 5.45871E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
4 | CORE_MID | Heating | 16617.30201 | 16617.30201 | 0.86876 | 0.86876 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
5 | CORE_TOP | Cooling | 29851.79438 | 29851.79438 | 2.67205 | 2.67205 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 33.60400 | 5.47481E-003 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
6 | CORE_TOP | Heating | 29153.83846 | 29153.83846 | 1.52891 | 1.52891 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 983.53657 | 52.93867 | 0.42469 | 0.00000 |
7 | PERIMETER_TOP_ZN_3 | Cooling | 9557.25749 | 9557.25749 | 0.85543 | 0.85543 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 33.75200 | 5.47504E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
8 | PERIMETER_TOP_ZN_3 | Heating | 13240.78097 | 13240.78097 | 0.69591 | 0.69591 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
9 | PERIMETER_TOP_ZN_2 | Cooling | 10809.13935 | 10809.13935 | 0.96747 | 0.96747 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:10:00 | 26.17933 | 5.46350E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
10 | PERIMETER_TOP_ZN_2 | Heating | 8719.23494 | 8719.23494 | 0.45830 | 0.45830 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
11 | PERIMETER_TOP_ZN_1 | Cooling | 13025.16395 | 13025.16395 | 1.16582 | 1.16582 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 33.53000 | 5.47470E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
12 | PERIMETER_TOP_ZN_1 | Heating | 13324.68885 | 13324.68885 | 0.70033 | 0.70033 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
13 | PERIMETER_TOP_ZN_4 | Cooling | 12607.49665 | 12607.49665 | 1.12843 | 1.12843 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 31.82800 | 5.47208E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
14 | PERIMETER_TOP_ZN_4 | Heating | 8719.08509 | 8719.08509 | 0.45829 | 0.45829 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
15 | PERIMETER_BOT_ZN_3 | Cooling | 7336.06961 | 7336.06961 | 0.65663 | 0.65663 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 33.90000 | 5.47527E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
16 | PERIMETER_BOT_ZN_3 | Heating | 9851.38272 | 9851.38272 | 0.51749 | 0.51749 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
17 | PERIMETER_BOT_ZN_2 | Cooling | 8815.01329 | 8815.01329 | 0.78900 | 0.78900 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 27.01800 | 5.46476E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
18 | PERIMETER_BOT_ZN_2 | Heating | 6552.46421 | 6552.46421 | 0.34424 | 0.34424 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
19 | PERIMETER_BOT_ZN_1 | Cooling | 10239.85816 | 10239.85816 | 0.91654 | 0.91654 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 33.65333 | 5.47489E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
20 | PERIMETER_BOT_ZN_1 | Heating | 9932.91234 | 9932.91234 | 0.52178 | 0.52178 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
21 | PERIMETER_BOT_ZN_4 | Cooling | 9750.82997 | 9750.82997 | 0.87276 | 0.87276 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 31.08800 | 5.47095E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
22 | PERIMETER_BOT_ZN_4 | Heating | 6552.39873 | 6552.39873 | 0.34424 | 0.34424 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
23 | PERIMETER_MID_ZN_3 | Cooling | 8266.01849 | 8266.01849 | 0.73986 | 0.73986 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 33.90000 | 5.47527E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
24 | PERIMETER_MID_ZN_3 | Heating | 10330.26796 | 10330.26796 | 0.54267 | 0.54267 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
25 | PERIMETER_MID_ZN_2 | Cooling | 10695.48227 | 10695.48227 | 0.95730 | 0.95730 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 25.76000 | 5.46288E-003 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
26 | PERIMETER_MID_ZN_2 | Heating | 6852.92312 | 6852.92312 | 0.36004 | 0.36004 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 131.26219 | 7.06516 | 5.66790E-002 | 0.00000 |
27 | PERIMETER_MID_ZN_1 | Cooling | 11733.71278 | 11733.71278 | 1.05024 | 1.05024 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 33.40667 | 5.47451E-003 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
28 | PERIMETER_MID_ZN_1 | Heating | 10401.95830 | 10401.95830 | 0.54644 | 0.54644 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 207.33814 | 11.15994 | 8.95286E-002 | 0.00000 |
29 | PERIMETER_MID_ZN_4 | Cooling | 11597.55301 | 11597.55301 | 1.03804 | 1.03804 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 31.82800 | 5.47208E-003 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
30 | PERIMETER_MID_ZN_4 | Heating | 6852.85342 | 6852.85342 | 0.36003 | 0.36003 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | -17.90000 | 9.55238E-004 | 131.25358 | 7.06470 | 5.66753E-002 | 0.00000 |
System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
1 | PACU_VAV_BOT | Cooling | Sensible | 74329.90 | 5.91450 | 5.91450 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
2 | PACU_VAV_BOT | Heating | Sensible | 28580.18 | 2.16504 | 2.16504 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:50:00 |
3 | PACU_VAV_MID | Cooling | Sensible | 67529.94 | 5.30548 | 5.30548 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
4 | PACU_VAV_MID | Heating | Sensible | 28586.40 | 2.67794 | 2.67794 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:30:00 |
5 | PACU_VAV_TOP | Cooling | Sensible | 77061.61 | 6.18298 | 6.18298 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 00:00:00 |
6 | PACU_VAV_TOP | Heating | Sensible | 28796.02 | 3.84174 | 3.84174 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 02:00:00 |
Component Type | Component Name | Input Field Description | Value | |
1 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 3.43210 |
2 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.21837 |
3 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.18600 |
4 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.63837 |
5 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.58231 |
6 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
7 | AirTerminal:SingleDuct:VAV:Reheat | CORE_BOTTOM VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.74477E-003 |
8 | Coil:Heating:Electric | CORE_BOTTOM VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 17306.43297 |
9 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.50780 |
10 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.29885 |
11 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.25400 |
12 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.63698 |
13 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.79693 |
14 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
15 | AirTerminal:SingleDuct:VAV:Reheat | CORE_MID VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.27489E-003 |
16 | Coil:Heating:Electric | CORE_MID VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 23552.52264 |
17 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 2.67205 |
18 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.28048 |
19 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.23800 |
20 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.63595 |
21 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.74794 |
22 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
23 | AirTerminal:SingleDuct:VAV:Reheat | CORE_TOP VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.35839E-003 |
24 | Coil:Heating:Electric | CORE_TOP VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 41449.40064 |
25 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.85543 |
26 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.18469 |
27 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.15700 |
28 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13430 |
29 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.49252 |
30 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
31 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06288E-003 |
32 | Coil:Heating:Electric | PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 18866.39098 |
33 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.96747 |
34 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.10339 |
35 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 8.80000E-002 |
36 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 8.51372E-002 |
37 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
38 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
39 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.68525E-003 |
40 | Coil:Heating:Electric | PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 12424.64992 |
41 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.16582 |
42 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.13552 |
43 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.11500 |
44 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13407 |
45 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.36139 |
46 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
47 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.81140E-003 |
48 | Coil:Heating:Electric | PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 18986.18357 |
49 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.12843 |
50 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 8.86322E-002 |
51 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 7.50000E-002 |
52 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 8.46323E-002 |
53 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
54 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
55 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_TOP_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 4.29866E-003 |
56 | Coil:Heating:Electric | PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 12424.43745 |
57 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.65663 |
58 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.24061 |
59 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.20500 |
60 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13461 |
61 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.64162 |
62 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
63 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.58348E-003 |
64 | Coil:Heating:Electric | PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 14029.28154 |
65 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.78900 |
66 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.12677 |
67 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.10800 |
68 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 8.52121E-002 |
69 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.33805 |
70 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
71 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.00544E-003 |
72 | Coil:Heating:Electric | PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 9332.44270 |
73 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.91654 |
74 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.17238 |
75 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.14700 |
76 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13473 |
77 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.45968 |
78 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
79 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.21025E-003 |
80 | Coil:Heating:Electric | PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 14145.69072 |
81 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.87276 |
82 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.11460 |
83 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 9.70000E-002 |
84 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 8.46580E-002 |
85 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30559 |
86 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
87 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_BOT_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.32472E-003 |
88 | Coil:Heating:Electric | PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 9332.35069 |
89 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.73986 |
90 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.21354 |
91 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.18200 |
92 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13465 |
93 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.56945 |
94 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
95 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_3 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.78419E-003 |
96 | Coil:Heating:Electric | PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 14711.88426 |
97 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 0.95730 |
98 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
99 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
100 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_2 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.64652E-003 |
101 | Coil:Heating:Electric | PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 9760.68173 |
102 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.05024 |
103 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 0.15043 |
104 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 0.12800 |
105 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 0.13443 |
106 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.40116 |
107 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
108 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_1 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.53267E-003 |
109 | Coil:Heating:Electric | PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 14814.24099 |
110 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Air Flow Rate [m3/s] | 1.03804 |
111 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Constant Minimum Air Flow Fraction | 9.63498E-002 |
112 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Constant Minimum Air Flow Fraction | 8.20000E-002 |
113 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Minimum Air Flow Rate [m3/s] | 8.51195E-002 |
114 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
115 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
116 | AirTerminal:SingleDuct:VAV:Reheat | PERIMETER_MID_ZN_4 VAV BOX COMPONENT | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.95434E-003 |
117 | Coil:Heating:Electric | PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Design Size Nominal Capacity [W] | 9760.58371 |
118 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.33352 |
119 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.07758 |
120 | AirLoopHVAC | PACU_VAV_BOT | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.66703 |
121 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Heating Design Air Flow Rate [m3/s] | 2.16504 |
122 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.91450 |
123 | AirLoopHVAC | PACU_VAV_BOT | Adjusted Main Design Air Flow Rate [m3/s] | 5.91450 |
124 | AirLoopHVAC | PACU_VAV_BOT | User Heating Air Flow Ratio [] | 0.30000 |
125 | AirLoopHVAC | PACU_VAV_BOT | Calculated Heating Air Flow Ratio [] | 0.36606 |
126 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.14662 |
127 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.07639 |
128 | AirLoopHVAC | PACU_VAV_MID | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.29325 |
129 | AirLoopHVAC | PACU_VAV_MID | Adjusted Heating Design Air Flow Rate [m3/s] | 2.67794 |
130 | AirLoopHVAC | PACU_VAV_MID | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.30548 |
131 | AirLoopHVAC | PACU_VAV_MID | Adjusted Main Design Air Flow Rate [m3/s] | 5.30548 |
132 | AirLoopHVAC | PACU_VAV_MID | User Heating Air Flow Ratio [] | 0.30000 |
133 | AirLoopHVAC | PACU_VAV_MID | Calculated Heating Air Flow Ratio [] | 0.50475 |
134 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.39460 |
135 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 1.07409 |
136 | AirLoopHVAC | PACU_VAV_TOP | Sum of Air Terminal Maximum Flow Rates [m3/s] | 6.78920 |
137 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Heating Design Air Flow Rate [m3/s] | 3.84174 |
138 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Cooling Design Air Flow Rate [m3/s] | 6.18298 |
139 | AirLoopHVAC | PACU_VAV_TOP | Adjusted Main Design Air Flow Rate [m3/s] | 6.18298 |
140 | AirLoopHVAC | PACU_VAV_TOP | User Heating Air Flow Ratio [] | 0.30000 |
141 | AirLoopHVAC | PACU_VAV_TOP | Calculated Heating Air Flow Ratio [] | 0.62134 |
142 | AirLoopHVAC | PACU_VAV_BOT | Design Supply Air Flow Rate [m3/s] | 5.91450 |
143 | AirLoopHVAC | PACU_VAV_MID | Design Supply Air Flow Rate [m3/s] | 5.30548 |
144 | AirLoopHVAC | PACU_VAV_TOP | Design Supply Air Flow Rate [m3/s] | 6.18298 |
145 | Controller:OutdoorAir | PACU_VAV_BOT_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.91450 |
146 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.91450 |
147 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 97905.89393 |
148 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
149 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.97130 |
150 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 32632.03445 |
151 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
152 | Coil:Heating:Fuel | PACU_VAV_BOT HEATING COIL | Design Size Nominal Capacity [W] | 24025.31301 |
153 | Fan:VariableVolume | PACU_VAV_BOT FAN | Design Size Maximum Flow Rate [m3/s] | 5.91450 |
154 | Controller:OutdoorAir | PACU_VAV_MID_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.30548 |
155 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 5.30548 |
156 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 87824.51915 |
157 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
158 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 1.76832 |
159 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 29271.91223 |
160 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
161 | Coil:Heating:Fuel | PACU_VAV_MID HEATING COIL | Design Size Nominal Capacity [W] | 25341.39992 |
162 | Fan:VariableVolume | PACU_VAV_MID FAN | Design Size Maximum Flow Rate [m3/s] | 5.30548 |
163 | Controller:OutdoorAir | PACU_VAV_TOP_OA_CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 6.18298 |
164 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Air Flow Rate [m3/s] | 6.18298 |
165 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Gross Rated Total Cooling Capacity [W] | 102350.31976 |
166 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size High Speed Rated Sensible Heat Ratio | 0.80066 |
167 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Rated Air Flow Rate [m3/s] | 2.06079 |
168 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Total Cooling Capacity [W] | 34113.36158 |
169 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | Design Size Low Speed Gross Rated Sensible Heat Ratio | 0.80066 |
170 | Coil:Heating:Fuel | PACU_VAV_TOP HEATING COIL | Design Size Nominal Capacity [W] | 24255.62452 |
171 | Fan:VariableVolume | PACU_VAV_TOP FAN | Design Size Maximum Flow Rate [m3/s] | 6.18298 |
172 | PlantLoop | SWHSYS1 | Maximum Loop Flow Rate [m3/s] | 5.36267E-005 |
173 | PlantLoop | SWHSYS1 | Plant Loop Volume [m3] | 6.43520E-003 |
174 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Flow Rate [m3/s] | 5.36267E-005 |
175 | Pump:ConstantSpeed | SWHSYS1 PUMP | Design Power Consumption [W] | 6.85023 |
176 | WaterHeater:Mixed | SWHSYS1 WATER HEATER | Use Side Design Flow Rate [m3/s] | 5.36267E-005 |
DX Coil Type | DX Coil Name | Fan Type | Fan Name | Standard Net Cooling Capacity {W} | Standard Net Cooling Capacity {Btu/h} | IEER {Btu/W-h} | COP 100% Capacity {W/W} | COP 75% Capacity {W/W} | COP 50% Capacity {W/W} | COP 25% Capacity {W/W} | EER 100% Capacity {Btu/W-h} | EER 75% Capacity {Btu/W-h} | EER 50% Capacity {Btu/W-h} | EER 25% Capacity {Btu/W-h} | Supply Air Flow 100% {kg/s} | Supply Air Flow 75% {kg/s} | Supply Air Flow 50% {kg/s} | Supply Air Flow 25% {kg/s} | |
1 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_BOT COOLING COIL | N/A | N/A | 96221.18 | 328320.28 | 11.23 | 2.80 | 3.22 | 3.39 | 3.54 | 9.54 | 10.98 | 11.58 | 12.07 | 5.5527 | 4.3900 | 2.9429 | 1.2463 |
2 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_MID COOLING COIL | N/A | N/A | 86313.28 | 294513.13 | 11.23 | 2.80 | 3.22 | 3.39 | 3.54 | 9.54 | 10.98 | 11.58 | 12.07 | 4.9810 | 3.9380 | 2.6399 | 1.1180 |
3 | Coil:Cooling:DX:TwoSpeed | PACU_VAV_TOP COOLING COIL | N/A | N/A | 100589.13 | 343224.34 | 11.23 | 2.80 | 3.22 | 3.39 | 3.54 | 9.54 | 10.98 | 11.58 | 12.07 | 5.8048 | 4.5893 | 3.0765 | 1.3029 |
Zone Name | # Surfaces | |
1 | CORE_BOTTOM | 7 |
2 | TOPFLOOR_PLENUM | 10 |
3 | MIDFLOOR_PLENUM | 14 |
4 | FIRSTFLOOR_PLENUM | 14 |
5 | CORE_MID | 7 |
6 | CORE_TOP | 7 |
7 | PERIMETER_TOP_ZN_3 | 8 |
8 | PERIMETER_TOP_ZN_2 | 8 |
9 | PERIMETER_TOP_ZN_1 | 8 |
10 | PERIMETER_TOP_ZN_4 | 8 |
11 | PERIMETER_BOT_ZN_3 | 12 |
12 | PERIMETER_BOT_ZN_2 | 10 |
13 | PERIMETER_BOT_ZN_1 | 12 |
14 | PERIMETER_BOT_ZN_4 | 10 |
15 | PERIMETER_MID_ZN_3 | 8 |
16 | PERIMETER_MID_ZN_2 | 8 |
17 | PERIMETER_MID_ZN_1 | 8 |
18 | PERIMETER_MID_ZN_4 | 8 |
Surface Name | Surface Class | Base Surface | Heat Transfer Algorithm | Construction | Nominal U (w/o film coefs) {W/m2-K} | Nominal U (with film coefs) {W/m2-K} | Solar Diffusing | Area (Net) {m2} | Area (Gross) {m2} | Area (Sunlit Calc) {m2} | Azimuth {deg} | Tilt {deg} | ~Width {m} | ~Height {m} | Reveal {m} | ExtBoundCondition | ExtConvCoeffCalc | IntConvCoeffCalc | SunExposure | WindExposure | ViewFactorToGround | ViewFactorToSky | ViewFactorToGround-IR | ViewFactorToSky-IR | #Sides | |
1 | CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
2 | CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
3 | CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
4 | CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
5 | CORE_BOT_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | CORE_BOT_ZN_5_FLOOR_FFACTOR | 5.650E-003 | 5.642E-003 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
6 | CORE_BOT_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
7 | CORE_BOTTOM_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_BOTTOM_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
8 | PERIMETER_TOP_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
9 | PERIMETER_TOP_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
10 | PERIMETER_TOP_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
11 | PERIMETER_TOP_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
12 | iz-PERIMETER_TOP_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 225.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
13 | iz-PERIMETER_TOP_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 135.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
14 | iz-PERIMETER_TOP_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 45.00 | 180.00 | 6.47 | 40.76 | 0.00 | PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
15 | iz-PERIMETER_TOP_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 315.00 | 180.00 | 6.47 | 24.13 | 0.00 | PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
16 | iz-CORE_TOP_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 180.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
17 | BUILDING_ROOF | Roof | CTF - ConductionTransferFunction | NONRES_ROOF | 0.186 | 0.180 | 1660.73 | 1660.73 | 1660.73 | 0.00 | 0.00 | 49.91 | 33.27 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
18 | PERIMETER_MID_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
19 | PERIMETER_MID_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
20 | PERIMETER_MID_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
21 | PERIMETER_MID_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
22 | iz-PERIMETER_MID_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
23 | iz-PERIMETER_MID_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
24 | iz-PERIMETER_MID_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
25 | iz-PERIMETER_MID_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
26 | iz-CORE_MID_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
27 | iz-PERIMETER_TOP_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
28 | iz-PERIMETER_TOP_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
29 | iz-PERIMETER_TOP_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
30 | iz-PERIMETER_TOP_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
31 | iz-CORE_TOP_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
32 | PERIMETER_BOT_PLENUM_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 60.85 | 60.85 | 60.85 | 0.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
33 | PERIMETER_BOT_PLENUM_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 40.57 | 40.57 | 40.57 | 90.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
34 | PERIMETER_BOT_PLENUM_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 60.85 | 60.85 | 60.85 | 180.00 | 90.00 | 49.91 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
35 | PERIMETER_BOT_PLENUM_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 40.57 | 40.57 | 40.57 | 270.00 | 90.00 | 33.27 | 1.22 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
36 | iz-PERIMETER_BOT_ZN_1_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
37 | iz-PERIMETER_BOT_ZN_2_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
38 | iz-PERIMETER_BOT_ZN_3_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
39 | iz-PERIMETER_BOT_ZN_4_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
40 | iz-CORE_BOT_ZN_5_CEILING | Floor | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.147 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | CORE_BOT_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
41 | iz-PERIMETER_MID_ZN_1_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
42 | iz-PERIMETER_MID_ZN_2_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
43 | iz-PERIMETER_MID_ZN_3_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
44 | iz-PERIMETER_MID_ZN_4_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
45 | iz-CORE_MID_ZN_5_FLOOR | Roof | CTF - ConductionTransferFunction | INT_SLAB_CEILING | 3.839 | 2.228 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
46 | CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
47 | CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
48 | CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
49 | CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
50 | CORE_MID_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
51 | CORE_MID_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 180.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_MID_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
52 | CORE_MID_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_MID_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
53 | CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
54 | CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
55 | CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
56 | CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | iz-CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
57 | CORE_TOP_ZN_5_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 983.54 | 983.54 | 983.54 | 0.00 | 180.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
58 | CORE_TOP_ZN_5_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 983.54 | 983.54 | 983.54 | 0.00 | 0.00 | 40.76 | 24.13 | 0.00 | iz-CORE_TOP_ZN_5_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
59 | CORE_TOP_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 1967.08 | 1967.08 | 1967.08 | 0.00 | 90.00 | 1967.08 | 1.00 | 0.00 | CORE_TOP_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
60 | PERIMETER_TOP_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 71.65 | 136.92 | 71.65 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
61 | PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_TOP_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_NORTH_0.378 | N/A | 2.062 | No | 65.26 | 65.26 | 65.26 | 0.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
62 | PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
63 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
64 | iz-CORE_TOP_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
65 | PERIMETER_TOP_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
66 | PERIMETER_TOP_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 225.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
67 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_TOP_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
68 | PERIMETER_TOP_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 47.77 | 91.28 | 47.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
69 | PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_TOP_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_EAST_0.378 | N/A | 2.062 | No | 43.51 | 43.51 | 43.51 | 90.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
70 | PERIMETER_TOP_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
71 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
72 | iz-CORE_TOP_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
73 | PERIMETER_TOP_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
74 | PERIMETER_TOP_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 315.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
75 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
76 | PERIMETER_TOP_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 71.65 | 136.92 | 71.65 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
77 | PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_TOP_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_SOUTH_0.378 | N/A | 2.062 | No | 65.26 | 65.26 | 65.26 | 180.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
78 | PERIMETER_TOP_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
79 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
80 | iz-CORE_TOP_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
81 | PERIMETER_TOP_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
82 | PERIMETER_TOP_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 45.00 | 0.00 | 6.47 | 49.91 | 0.00 | iz-PERIMETER_TOP_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
83 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_TOP_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
84 | PERIMETER_TOP_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_TOP | 1.032 | 0.894 | 47.77 | 91.28 | 47.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
85 | PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_TOP_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_WEST_0.378 | N/A | 2.062 | No | 43.51 | 43.51 | 43.51 | 270.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
86 | PERIMETER_TOP_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
87 | iz-PERIMETER_TOP_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_TOP_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
88 | iz-CORE_TOP_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_TOP_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
89 | PERIMETER_TOP_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_TOP_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
90 | PERIMETER_TOP_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 135.00 | 0.00 | 6.47 | 33.27 | 0.00 | iz-PERIMETER_TOP_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
91 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_TOP_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
92 | PERIMETER_BOT_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 67.75 | 136.92 | 67.75 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
93 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_NORTH_0.378 | N/A | 2.062 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
94 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_NORTH_0.378 | N/A | 2.062 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
95 | PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | Window | PERIMETER_BOT_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_NORTH_0.378 | N/A | 2.062 | No | 21.75 | 21.75 | 21.75 | 0.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
96 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
97 | PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | Door | PERIMETER_BOT_ZN_3_WALL_NORTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 0.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
98 | PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
99 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
100 | iz-CORE_BOT_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
101 | PERIMETER_BOT_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 0.224 | 0.213 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
102 | PERIMETER_BOT_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
103 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_BOT_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
104 | PERIMETER_BOT_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 45.82 | 91.28 | 45.82 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
105 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_EAST_0.378 | N/A | 2.062 | No | 41.85 | 41.85 | 41.85 | 90.00 | 90.00 | 30.84 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
106 | PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | Window | PERIMETER_BOT_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_EAST_0.378 | N/A | 2.062 | No | 1.65 | 1.65 | 1.65 | 90.00 | 90.00 | 1.22 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
107 | PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | Door | PERIMETER_BOT_ZN_2_WALL_EAST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 90.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
108 | PERIMETER_BOT_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
109 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
110 | iz-CORE_BOT_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
111 | PERIMETER_BOT_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 0.237 | 0.224 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
112 | PERIMETER_BOT_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
113 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
114 | PERIMETER_BOT_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 67.75 | 136.92 | 67.75 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
115 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_SOUTH_0.378 | N/A | 2.062 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
116 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_SOUTH_0.378 | N/A | 2.062 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
117 | PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | Window | PERIMETER_BOT_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_SOUTH_0.378 | N/A | 2.062 | No | 21.75 | 21.75 | 21.75 | 180.00 | 90.00 | 15.82 | 1.37 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
118 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
119 | PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | Door | PERIMETER_BOT_ZN_1_WALL_SOUTH | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 180.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
120 | PERIMETER_BOT_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
121 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
122 | iz-CORE_BOT_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
123 | PERIMETER_BOT_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 0.224 | 0.213 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
124 | PERIMETER_BOT_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
125 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_BOT_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
126 | PERIMETER_BOT_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_GRD | 0.802 | 0.716 | 45.82 | 91.28 | 45.82 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
127 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_WEST_0.378 | N/A | 2.062 | No | 41.85 | 41.85 | 41.85 | 270.00 | 90.00 | 30.84 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
128 | PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | Window | PERIMETER_BOT_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_WEST_0.378 | N/A | 2.062 | No | 1.65 | 1.65 | 1.65 | 270.00 | 90.00 | 1.22 | 1.36 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
129 | PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | Door | PERIMETER_BOT_ZN_4_WALL_WEST | CTF - ConductionTransferFunction | SWINGING DOOR_CON | 2.101 | 2.101 | 1.95 | 1.95 | 1.95 | 270.00 | 90.00 | 0.91 | 2.13 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | |
130 | PERIMETER_BOT_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
131 | iz-PERIMETER_BOT_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_BOT_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
132 | iz-CORE_BOT_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_BOT_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
133 | PERIMETER_BOT_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 0.237 | 0.224 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | FCGround | N/A-FCGround | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
134 | PERIMETER_BOT_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_BOT_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
135 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_BOT_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
136 | PERIMETER_MID_ZN_3_WALL_NORTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 71.65 | 136.92 | 71.65 | 0.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
137 | PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | Window | PERIMETER_MID_ZN_3_WALL_NORTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_NORTH_0.378 | N/A | 2.062 | No | 65.26 | 65.26 | 65.26 | 0.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
138 | PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
139 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
140 | iz-CORE_MID_ZN_5_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 180.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
141 | PERIMETER_MID_ZN_3_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 0.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
142 | PERIMETER_MID_ZN_3_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 180.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_3_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
143 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.68 | 414.68 | 414.68 | 0.00 | 90.00 | 414.68 | 1.00 | 0.00 | PERIMETER_MID_ZN_3_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
144 | PERIMETER_MID_ZN_2_WALL_EAST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 47.77 | 91.28 | 47.77 | 90.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
145 | PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | Window | PERIMETER_MID_ZN_2_WALL_EAST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_EAST_0.378 | N/A | 2.062 | No | 43.51 | 43.51 | 43.51 | 90.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
146 | PERIMETER_MID_ZN_2_WALL_NORTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_2_WALL_NORTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
147 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 225.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
148 | iz-CORE_MID_ZN_5_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 270.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
149 | PERIMETER_MID_ZN_2_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.26 | 131.26 | 131.26 | 90.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
150 | PERIMETER_MID_ZN_2_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.26 | 131.26 | 131.26 | 270.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_2_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
151 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_2_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
152 | PERIMETER_MID_ZN_1_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 71.65 | 136.92 | 71.65 | 180.00 | 90.00 | 49.91 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
153 | PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | Window | PERIMETER_MID_ZN_1_WALL_SOUTH | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_SOUTH_0.378 | N/A | 2.062 | No | 65.26 | 65.26 | 65.26 | 180.00 | 90.00 | 49.91 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
154 | PERIMETER_MID_ZN_1_WALL_EAST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_1_WALL_EAST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
155 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 315.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
156 | iz-CORE_MID_ZN_5_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 111.82 | 111.82 | 111.82 | 0.00 | 90.00 | 40.76 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
157 | PERIMETER_MID_ZN_1_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 207.34 | 207.34 | 207.34 | 180.00 | 180.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
158 | PERIMETER_MID_ZN_1_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 207.34 | 207.34 | 207.34 | 0.00 | 0.00 | 40.76 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_1_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
159 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 414.67 | 414.67 | 414.67 | 0.00 | 90.00 | 414.67 | 1.00 | 0.00 | PERIMETER_MID_ZN_1_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 | ||
160 | PERIMETER_MID_ZN_4_WALL_WEST | Wall | CTF - ConductionTransferFunction | NONRES_EXT_WALL_MID | 0.789 | 0.705 | 47.77 | 91.28 | 47.77 | 270.00 | 90.00 | 33.27 | 2.74 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
161 | PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | Window | PERIMETER_MID_ZN_4_WALL_WEST | Window5 Detailed Fenestration | WINDOW_U_0.363_SHGC_WEST_0.378 | N/A | 2.062 | No | 43.51 | 43.51 | 43.51 | 270.00 | 90.00 | 33.27 | 1.31 | 0.00 | ExternalEnvironment | ASHRAETARP | ASHRAETARP | SunExposed | WindExposed | 0.50 | 0.50 | 0.50 | 0.50 | 4 |
162 | PERIMETER_MID_ZN_4_WALL_SOUTH | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 135.00 | 90.00 | 6.47 | 2.74 | 0.00 | iz-PERIMETER_MID_ZN_4_WALL_SOUTH | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
163 | iz-PERIMETER_MID_ZN_3_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 17.74 | 17.74 | 17.74 | 45.00 | 90.00 | 6.47 | 2.74 | 0.00 | PERIMETER_MID_ZN_3_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
164 | iz-CORE_MID_ZN_5_WALL_WEST | Wall | CTF - ConductionTransferFunction | INT_WALL | 6.299 | 3.242 | 66.19 | 66.19 | 66.19 | 90.00 | 90.00 | 24.13 | 2.74 | 0.00 | CORE_MID_ZN_5_WALL_WEST | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.50 | 0.50 | 0.50 | 0.50 | 4 | ||
165 | PERIMETER_MID_ZN_4_FLOOR | Floor | CTF - ConductionTransferFunction | INT_SLAB_FLOOR | 3.839 | 1.986 | 131.25 | 131.25 | 131.25 | 270.00 | 180.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_FLOOR | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 1.00 | 0.00 | 1.00 | 0.00 | 4 | ||
166 | PERIMETER_MID_ZN_4_CEILING | Roof | CTF - ConductionTransferFunction | DROPCEILING | 4.488 | 2.432 | 131.25 | 131.25 | 131.25 | 90.00 | 0.00 | 24.13 | 6.47 | 0.00 | iz-PERIMETER_MID_ZN_4_CEILING | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 1.00 | 0.00 | 1.00 | 4 | ||
167 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Internal Mass | CTF - ConductionTransferFunction | INTERIORFURNISHINGS | 0.800 | 0.800 | 262.51 | 262.51 | 262.51 | 0.00 | 90.00 | 262.51 | 1.00 | 0.00 | PERIMETER_MID_ZN_4_INTERNALMASS_1 | Other/Same Surface Int Conv | ASHRAETARP | NoSun | NoWind | 0.00 | 0.50 | 1.00 | 0.00 | 0 |
Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
1 | RUNPERIOD 1 | WeatherFileRunPeriod | 01/01/2017 | 12/31/2017 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
Special Day Name | Special Day Type | Source | Start Date | Duration {#days} | |
1 | NEW YEARS DAY | Holiday | InputFile | 01/01 | 1Environment:Special Days |
Daylight Saving Indicator | Source | Start Date | End Date | |
1 | Yes | InputFile | 03/12 | 11/05 |
Style | Unit Conversion | |
1 | Commaandhtml | commaandhtml |
Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
1 | CORE_BOTTOM | RunPeriod: RUNPERIOD 1 | 4.1819463804E-002 | 9.5397646487E-002 | Pass | Pass | 2.2567748139E-002 | 0.1487197171 | Pass | Pass |
2 | TOPFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 0.1201826217 | 8.2769620152E-002 | Pass | Pass | 0.1471276956 | 0.3477809282 | Pass | Pass |
3 | MIDFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 2.9706724777E-002 | 3.3445104554E-002 | Pass | Pass | 3.9516464413E-002 | 0.1932179274 | Pass | Pass |
4 | FIRSTFLOOR_PLENUM | RunPeriod: RUNPERIOD 1 | 2.6032008765E-002 | 3.0298598249E-002 | Pass | Pass | 4.4085708890E-002 | 0.2328475436 | Pass | Pass |
5 | CORE_MID | RunPeriod: RUNPERIOD 1 | 2.9202397179E-002 | 5.1478376125E-002 | Pass | Pass | 3.4840854430E-002 | 0.1825451440 | Pass | Pass |
6 | CORE_TOP | RunPeriod: RUNPERIOD 1 | 5.0401631043E-002 | 2.5495811735E-002 | Pass | Pass | 0.1558772070 | 0.3762252214 | Pass | Pass |
7 | PERIMETER_TOP_ZN_3 | RunPeriod: RUNPERIOD 1 | 0.1063276969 | 0.1616682821 | Pass | Pass | 22.0022025513 | 119.8115243721 | Pass | Pass |
8 | PERIMETER_TOP_ZN_2 | RunPeriod: RUNPERIOD 1 | 0.1199911417 | 0.1465292370 | Pass | Pass | 26.1717623860 | 170.9778405338 | Pass | Pass |
9 | PERIMETER_TOP_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1576807450 | 0.1520047056 | Pass | Pass | 3.4221058845 | 36.6654082489 | Pass | Pass |
10 | PERIMETER_TOP_ZN_4 | RunPeriod: RUNPERIOD 1 | 0.1393950403 | 0.1387320948 | Pass | Pass | 25.0609136120 | 138.8250869803 | Pass | Pass |
11 | PERIMETER_BOT_ZN_3 | RunPeriod: RUNPERIOD 1 | 3.0339395185E-002 | 3.1999470834E-002 | Pass | Pass | 2.0833551635E-002 | 0.1419766885 | Pass | Pass |
12 | PERIMETER_BOT_ZN_2 | RunPeriod: RUNPERIOD 1 | 7.8230313849E-002 | 0.1129931989 | Pass | Pass | 2.1859508262E-002 | 0.1462904143 | Pass | Pass |
13 | PERIMETER_BOT_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1322740969 | 0.1444325926 | Pass | Pass | 2.1136549948E-002 | 0.1438497166 | Pass | Pass |
14 | PERIMETER_BOT_ZN_4 | RunPeriod: RUNPERIOD 1 | 7.2258693267E-002 | 0.1031104197 | Pass | Pass | 2.0819817986E-002 | 0.1395081669 | Pass | Pass |
15 | PERIMETER_MID_ZN_3 | RunPeriod: RUNPERIOD 1 | 3.2418745640E-002 | 3.2138754394E-002 | Pass | Pass | 3.5145670935E-002 | 0.1813626524 | Pass | Pass |
16 | PERIMETER_MID_ZN_2 | RunPeriod: RUNPERIOD 1 | 9.3804472764E-002 | 0.1347771219 | Pass | Pass | 3.5387567669E-002 | 0.1859576128 | Pass | Pass |
17 | PERIMETER_MID_ZN_1 | RunPeriod: RUNPERIOD 1 | 0.1641859933 | 0.1632010727 | Pass | Pass | 3.5202738453E-002 | 0.1834050387 | Pass | Pass |
18 | PERIMETER_MID_ZN_4 | RunPeriod: RUNPERIOD 1 | 8.9442385791E-002 | 0.1088480491 | Pass | Pass | 3.2801008183E-002 | 0.1663920195 | Pass | Pass |
Report: Annual Heat Emissions Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Heat Emission by ComponentsEnvelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
Heat Emissions [GJ] | 4141.85 | 127.19 | 0.00 | 1949.68 | 892.48 | 7111.21 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
SizingPeriod:DesignDayMaximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | -17.90 | 0.00 | -17.90 | Wetbulb [C] | 2.50 | 180.00 |
DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 14.80 | 15.00 | Wetbulb [C] | 3.60 | 30.00 |
Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
Jan | 11.00 | 10 | |||
Feb | 15.00 | 16 | |||
Mar | 88.00 | 32 | |||
Apr | 159.00 | 54 | |||
May | 30.00 | 24 | |||
Jun | 11.00 | 4 | |||
Jul | 167.00 | 26 | |||
Aug | 33.00 | 24 | |||
Sep | 8.00 | 8 | |||
Oct | 13.00 | 10 | |||
Nov | 12.00 | 22 | |||
Dec | 11.00 | 18 |
Value | |
None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Opaque ExteriorConstruction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_PLENUM_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_TOP_PLENUM_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_TOP_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_TOP_PLENUM_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 40.57 | 40.57 | 270.00 | 90.00 | W |
BUILDING_ROOF | NONRES_ROOF | 0.30 | 0.182 | 0.186 | 1660.73 | 1660.73 | 0.00 | 0.00 | |
PERIMETER_MID_PLENUM_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_MID_PLENUM_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_MID_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_MID_PLENUM_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_BOT_PLENUM_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 60.85 | 60.85 | 0.00 | 90.00 | N |
PERIMETER_BOT_PLENUM_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 40.57 | 40.57 | 90.00 | 90.00 | E |
PERIMETER_BOT_PLENUM_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 60.85 | 60.85 | 180.00 | 90.00 | S |
PERIMETER_BOT_PLENUM_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 40.57 | 40.57 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_3_WALL_NORTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 136.92 | 71.65 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_2_WALL_EAST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 91.28 | 47.77 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 136.92 | 71.65 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_4_WALL_WEST | NONRES_EXT_WALL_TOP | 0.30 | 0.894 | 1.032 | 91.28 | 47.77 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_3_WALL_NORTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 136.92 | 67.75 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_3_FLOOR | PERIMETER_BOT_ZN_3_FLOOR_FFACTOR | 1.00 | 0.216 | 0.224 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_BOT_ZN_2_WALL_EAST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 91.28 | 45.82 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_2_FLOOR | PERIMETER_BOT_ZN_2_FLOOR_FFACTOR | 1.00 | 0.228 | 0.237 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_BOT_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 136.92 | 67.75 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_1_FLOOR | PERIMETER_BOT_ZN_1_FLOOR_FFACTOR | 1.00 | 0.216 | 0.224 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_BOT_ZN_4_WALL_WEST | NONRES_EXT_WALL_GRD | 0.30 | 0.716 | 0.802 | 91.28 | 45.82 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_4_FLOOR | PERIMETER_BOT_ZN_4_FLOOR_FFACTOR | 1.00 | 0.228 | 0.237 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_3_WALL_NORTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 136.92 | 71.65 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_2_WALL_EAST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 91.28 | 47.77 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_1_WALL_SOUTH | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 136.92 | 71.65 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_4_WALL_WEST | NONRES_EXT_WALL_MID | 0.30 | 0.705 | 0.789 | 91.28 | 47.77 | 270.00 | 90.00 | W |
Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_BOT_ZN_5_FLOOR | CORE_BOT_ZN_5_FLOOR_FFACTOR | 1.00 | 0.006 | 0.006 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 135.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 315.00 | 180.00 | |
iz-CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_TOP_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
iz-PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 90.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 180.00 | |
iz-PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 270.00 | 180.00 | |
iz-CORE_BOT_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 180.00 | |
iz-PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 0.00 | |
iz-PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 270.00 | 0.00 | |
iz-PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 0.00 | |
iz-PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 90.00 | 0.00 | |
iz-CORE_MID_ZN_5_FLOOR | INT_SLAB_CEILING | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_MID_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_MID_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 180.00 | 0.00 | |
CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
CORE_TOP_ZN_5_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 983.54 | 983.54 | 0.00 | 180.00 | |
CORE_TOP_ZN_5_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 983.54 | 983.54 | 0.00 | 0.00 | |
PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_TOP_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_TOP_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_TOP_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 225.00 | 0.00 | |
PERIMETER_TOP_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_TOP_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_TOP_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_TOP_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 315.00 | 0.00 | |
PERIMETER_TOP_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_TOP_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_TOP_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_TOP_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 45.00 | 0.00 | |
PERIMETER_TOP_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_TOP_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_TOP_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_TOP_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_TOP_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 135.00 | 0.00 | |
PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_BOT_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_BOT_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_BOT_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_BOT_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_BOT_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_BOT_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_BOT_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_BOT_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_BOT_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_BOT_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_BOT_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_BOT_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-CORE_MID_ZN_5_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 180.00 | 90.00 | S |
PERIMETER_MID_ZN_3_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 0.00 | 180.00 | |
PERIMETER_MID_ZN_3_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 180.00 | 0.00 | |
PERIMETER_MID_ZN_2_WALL_NORTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 225.00 | 90.00 | W |
iz-CORE_MID_ZN_5_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 270.00 | 90.00 | W |
PERIMETER_MID_ZN_2_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.26 | 131.26 | 90.00 | 180.00 | |
PERIMETER_MID_ZN_2_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.26 | 131.26 | 270.00 | 0.00 | |
PERIMETER_MID_ZN_1_WALL_EAST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 315.00 | 90.00 | N |
iz-CORE_MID_ZN_5_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 111.82 | 111.82 | 0.00 | 90.00 | N |
PERIMETER_MID_ZN_1_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 207.34 | 207.34 | 180.00 | 180.00 | |
PERIMETER_MID_ZN_1_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 207.34 | 207.34 | 0.00 | 0.00 | |
PERIMETER_MID_ZN_4_WALL_SOUTH | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 135.00 | 90.00 | S |
iz-PERIMETER_MID_ZN_3_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 17.74 | 17.74 | 45.00 | 90.00 | E |
iz-CORE_MID_ZN_5_WALL_WEST | INT_WALL | 0.30 | 2.511 | 6.299 | 66.19 | 66.19 | 90.00 | 90.00 | E |
PERIMETER_MID_ZN_4_FLOOR | INT_SLAB_FLOOR | 0.30 | 1.887 | 3.839 | 131.25 | 131.25 | 270.00 | 180.00 | |
PERIMETER_MID_ZN_4_CEILING | DROPCEILING | 0.30 | 2.031 | 4.488 | 131.25 | 131.25 | 90.00 | 0.00 | |
CORE_BOTTOM_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_MID_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
CORE_TOP_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 1967.08 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_TOP_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_BOT_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_3_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.68 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_2_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_1_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 414.67 | 0.00 | 90.00 | N | ||
PERIMETER_MID_ZN_4_INTERNALMASS_1 | INTERIORFURNISHINGS | 0.30 | 0.800 | 262.51 | 0.00 | 90.00 | N |
Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.363_SHGC_NORTH_0.378 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.062 | 0.379 | 0.417 | No | PERIMETER_TOP_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.363_SHGC_EAST_0.378 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.062 | 0.379 | 0.417 | No | PERIMETER_TOP_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.363_SHGC_SOUTH_0.378 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.062 | 0.379 | 0.417 | No | PERIMETER_TOP_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.363_SHGC_WEST_0.378 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.062 | 0.379 | 0.417 | No | PERIMETER_TOP_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | WINDOW_U_0.363_SHGC_NORTH_0.378 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | WINDOW_U_0.363_SHGC_NORTH_0.378 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | WINDOW_U_0.363_SHGC_NORTH_0.378 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | WINDOW_U_0.363_SHGC_EAST_0.378 | 41.85 | 0.00 | 0.00 | 41.85 | 41.85 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | WINDOW_U_0.363_SHGC_EAST_0.378 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | WINDOW_U_0.363_SHGC_SOUTH_0.378 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | WINDOW_U_0.363_SHGC_SOUTH_0.378 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | WINDOW_U_0.363_SHGC_SOUTH_0.378 | 21.75 | 0.00 | 0.00 | 21.75 | 21.75 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | WINDOW_U_0.363_SHGC_WEST_0.378 | 41.85 | 0.00 | 0.00 | 41.85 | 41.85 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | WINDOW_U_0.363_SHGC_WEST_0.378 | 1.65 | 0.00 | 0.00 | 1.65 | 1.65 | 2.062 | 0.379 | 0.417 | No | PERIMETER_BOT_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | WINDOW_U_0.363_SHGC_NORTH_0.378 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.062 | 0.379 | 0.417 | No | PERIMETER_MID_ZN_3_WALL_NORTH | 0.00 | 90.00 | N | |||||||
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | WINDOW_U_0.363_SHGC_EAST_0.378 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.062 | 0.379 | 0.417 | No | PERIMETER_MID_ZN_2_WALL_EAST | 90.00 | 90.00 | E | |||||||
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | WINDOW_U_0.363_SHGC_SOUTH_0.378 | 65.26 | 0.00 | 0.00 | 65.26 | 65.26 | 2.062 | 0.379 | 0.417 | No | PERIMETER_MID_ZN_1_WALL_SOUTH | 180.00 | 90.00 | S | |||||||
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | WINDOW_U_0.363_SHGC_WEST_0.378 | 43.51 | 0.00 | 0.00 | 43.51 | 43.51 | 2.062 | 0.379 | 0.417 | No | PERIMETER_MID_ZN_4_WALL_WEST | 270.00 | 90.00 | W | |||||||
Total or Average | 652.62 | 2.062 | 0.379 | 0.417 | |||||||||||||||||
North Total or Average | 195.79 | 2.062 | 0.379 | 0.417 | |||||||||||||||||
Non-North Total or Average | 456.84 | 2.062 | 0.379 | 0.417 |
Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
None |
Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | |
Total or Average | 0.00 | - | - | - |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_3_WALL_NORTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_3_WALL_NORTH |
PERIMETER_BOT_ZN_2_WALL_EAST_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_2_WALL_EAST |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR1 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_1_WALL_SOUTH_DOOR2 | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_1_WALL_SOUTH |
PERIMETER_BOT_ZN_4_WALL_WEST_DOOR | SWINGING DOOR_CON | 1.598 | 2.101 | 1.95 | PERIMETER_BOT_ZN_4_WALL_WEST |
Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Sunlit FractionMarch 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2_WALL_EAST_WINDOW | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
PERIMETER_MID_ZN_4_WALL_WEST_WINDOW | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
Name | Type | Shaded Construction | Control | Glare Control | |
None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Interior LightingZone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
CORE_BOTTOM_LIGHTS | CORE_BOTTOM | CORE_BOTTOM | GENERAL | 6.6636 | 983.54 | 6553.91 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 45.19 | 0.0000 | Y | 55.60 |
CORE_MID_LIGHTS | CORE_MID | CORE_MID | GENERAL | 6.6636 | 983.54 | 6553.91 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 45.19 | 0.0000 | Y | 55.60 |
CORE_TOP_LIGHTS | CORE_TOP | CORE_TOP | GENERAL | 6.6636 | 983.54 | 6553.91 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 45.19 | 0.0000 | Y | 55.60 |
PERIMETER_TOP_ZN_3_LIGHTS | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3 | GENERAL | 6.6636 | 207.34 | 1381.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.95 | 0.0000 | Y | 6.73 |
PERIMETER_TOP_ZN_2_LIGHTS | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2 | GENERAL | 6.6636 | 131.26 | 874.68 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.91 | 0.0000 | Y | 4.25 |
PERIMETER_TOP_ZN_1_LIGHTS | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1 | GENERAL | 6.6636 | 207.34 | 1381.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.60 | 0.0000 | Y | 6.64 |
PERIMETER_TOP_ZN_4_LIGHTS | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4 | GENERAL | 6.6636 | 131.25 | 874.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.60 | 0.0000 | Y | 4.20 |
PERIMETER_BOT_ZN_3_LIGHTS | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3 | GENERAL | 6.6636 | 207.34 | 1381.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.91 | 0.0000 | Y | 6.72 |
PERIMETER_BOT_ZN_2_LIGHTS | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2 | GENERAL | 6.6636 | 131.26 | 874.68 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.87 | 0.0000 | Y | 4.25 |
PERIMETER_BOT_ZN_1_LIGHTS | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1 | GENERAL | 6.6636 | 207.34 | 1381.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.56 | 0.0000 | Y | 6.63 |
PERIMETER_BOT_ZN_4_LIGHTS | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4 | GENERAL | 6.6636 | 131.25 | 874.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.57 | 0.0000 | Y | 4.20 |
PERIMETER_MID_ZN_3_LIGHTS | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3 | GENERAL | 6.6636 | 207.34 | 1381.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.95 | 0.0000 | Y | 6.73 |
PERIMETER_MID_ZN_2_LIGHTS | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2 | GENERAL | 6.6636 | 131.26 | 874.68 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.91 | 0.0000 | Y | 4.25 |
PERIMETER_MID_ZN_1_LIGHTS | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1 | GENERAL | 6.6636 | 207.34 | 1381.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.60 | 0.0000 | Y | 6.64 |
PERIMETER_MID_ZN_4_LIGHTS | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4 | GENERAL | 6.6636 | 131.25 | 874.62 | LightsWired | LTG_SCH_OFFICE | 47.17 | 168.00 | 25.60 | 0.0000 | Y | 4.20 |
Interior Lighting Total | 6.6636 | 4982.19 | 33199.39 | 232.25 |
Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
PERIMETER_BOT_ZN_1_DAYLREFPT1 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1381.62 | 529.85 |
PERIMETER_BOT_ZN_1_DAYLREFPT2 | PERIMETER_BOT_ZN_1 | PERIMETER_BOT_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1381.62 | 192.74 |
PERIMETER_BOT_ZN_2_DAYLREFPT1 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 874.68 | 335.44 |
PERIMETER_BOT_ZN_2_DAYLREFPT2 | PERIMETER_BOT_ZN_2 | PERIMETER_BOT_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 874.68 | 122.02 |
PERIMETER_BOT_ZN_3_DAYLREFPT1 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1381.62 | 529.85 |
PERIMETER_BOT_ZN_3_DAYLREFPT2 | PERIMETER_BOT_ZN_3 | PERIMETER_BOT_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1381.62 | 192.74 |
PERIMETER_BOT_ZN_4_DAYLREFPT1 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 874.62 | 335.42 |
PERIMETER_BOT_ZN_4_DAYLREFPT2 | PERIMETER_BOT_ZN_4 | PERIMETER_BOT_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 874.62 | 122.01 |
PERIMETER_MID_ZN_1_DAYLREFPT1 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1381.62 | 529.85 |
PERIMETER_MID_ZN_1_DAYLREFPT2 | PERIMETER_MID_ZN_1 | PERIMETER_MID_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1381.62 | 192.74 |
PERIMETER_MID_ZN_2_DAYLREFPT1 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 874.68 | 335.44 |
PERIMETER_MID_ZN_2_DAYLREFPT2 | PERIMETER_MID_ZN_2 | PERIMETER_MID_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 874.68 | 122.02 |
PERIMETER_MID_ZN_3_DAYLREFPT1 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1381.62 | 529.85 |
PERIMETER_MID_ZN_3_DAYLREFPT2 | PERIMETER_MID_ZN_3 | PERIMETER_MID_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1381.62 | 192.74 |
PERIMETER_MID_ZN_4_DAYLREFPT1 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 874.62 | 335.42 |
PERIMETER_MID_ZN_4_DAYLREFPT2 | PERIMETER_MID_ZN_4 | PERIMETER_MID_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 874.62 | 122.01 |
PERIMETER_TOP_ZN_1_DAYLREFPT1 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1381.62 | 529.85 |
PERIMETER_TOP_ZN_1_DAYLREFPT2 | PERIMETER_TOP_ZN_1 | PERIMETER_TOP_ZN_1_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1381.62 | 192.74 |
PERIMETER_TOP_ZN_2_DAYLREFPT1 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 874.68 | 335.44 |
PERIMETER_TOP_ZN_2_DAYLREFPT2 | PERIMETER_TOP_ZN_2 | PERIMETER_TOP_ZN_2_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 874.68 | 122.02 |
PERIMETER_TOP_ZN_3_DAYLREFPT1 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 1381.62 | 529.85 |
PERIMETER_TOP_ZN_3_DAYLREFPT2 | PERIMETER_TOP_ZN_3 | PERIMETER_TOP_ZN_3_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 1381.62 | 192.74 |
PERIMETER_TOP_ZN_4_DAYLREFPT1 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.38 | 874.62 | 335.42 |
PERIMETER_TOP_ZN_4_DAYLREFPT2 | PERIMETER_TOP_ZN_4 | PERIMETER_TOP_ZN_4_DAYLCTRL | SplitFlux | Continuous/Off | 0.14 | 874.62 | 122.01 |
Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
EXTERIOR_LIGHTS_A | 563.81 | AstronomicalClock | - | 42.26 | 42.26 | 4.47 | |
EXTERIOR_LIGHTS_B | 407.66 | AstronomicalClock | - | 83.67 | 62.97 | 4.82 | |
EXTERIOR_LIGHTS_C | 4714.72 | AstronomicalClock | - | 83.67 | 46.88 | 41.49 | |
Exterior Lighting Total | 5686.19 | 50.78 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Central PlantType | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | 97905.89 | 78388.87 | 19517.02 | 0.80 | 3.40 | |||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | 87824.52 | 70317.16 | 17507.36 | 0.80 | 3.40 | |||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | 102350.32 | 81947.32 | 20403.00 | 0.80 | 3.40 |
DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
PACU_VAV_BOT COOLING COIL | 96221.2 | 2.80 | 9.54 | N/A | N/A | 11.23 | |
PACU_VAV_MID COOLING COIL | 86313.3 | 2.80 | 9.54 | N/A | N/A | 11.23 | |
PACU_VAV_TOP COOLING COIL | 100589.1 | 2.80 | 9.54 | N/A | N/A | 11.23 |
DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | ||||||||
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed |
DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
None |
Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | 17306.43 | 1.00 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | 23552.52 | 1.00 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | 41449.40 | 1.00 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 18866.39 | 1.00 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 12424.65 | 1.00 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 18986.18 | 1.00 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 12424.44 | 1.00 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 14029.28 | 1.00 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 9332.44 | 1.00 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 14145.69 | 1.00 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 9332.35 | 1.00 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | 14711.88 | 1.00 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | 9760.68 | 1.00 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | 14814.24 | 1.00 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | 9760.58 | 1.00 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | 24025.31 | 0.80 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | 25341.40 | 0.80 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | 24255.62 | 0.80 |
Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
PACU_VAV_BOT FAN | Fan:VariableVolume | 0.60 | 1314.72 | 5.91 | 12863.37 | 2174.89 | 1.00 | 1.13 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 |
PACU_VAV_MID FAN | Fan:VariableVolume | 0.60 | 1314.72 | 5.31 | 11538.82 | 2174.89 | 1.00 | 1.14 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 |
PACU_VAV_TOP FAN | Fan:VariableVolume | 0.60 | 1314.72 | 6.18 | 13447.30 | 2174.89 | 1.00 | 1.13 | General | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 |
Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
SWHSYS1 PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000054 | 6.85 | 127739.32 | 0.30 | General |
Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
SWHSYS1 WATER HEATER | WaterHeater:Mixed | 0.38 | 29307.11 | 0.81 | 0.98 | 0.18 |
DX Cooling Coil Type | Assocated Fan | Net Cooling Capacity [W] | COP [W/W] | EER [Btu/W-h] | IEER [Btu/W-h] | Supply Air Flow 100% [kg/s] | COP 75% Capacity [W/W] | EER 75% Capacity [Btu/W-h] | Supply Air Flow 75% [kg/s] | COP 50% Capacity [W/W] | EER 50% Capacity [Btu/W-h] | Supply Air Flow 50% [kg/s] | COP 25% Capacity [W/W] | EER 25% Capacity [Btu/W-h] | Supply Air Flow 25% [kg/s] | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 96221.18 | 2.80 | 9.54 | 11.23 | 5.5527 | 3.22 | 10.98 | 4.3900 | 3.39 | 11.58 | 2.9429 | 3.54 | 12.07 | 1.2463 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 86313.28 | 2.80 | 9.54 | 11.23 | 4.9810 | 3.22 | 10.98 | 3.9380 | 3.39 | 11.58 | 2.6399 | 3.54 | 12.07 | 1.1180 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | None | 100589.13 | 2.80 | 9.54 | 11.23 | 5.8048 | 3.22 | 10.98 | 4.5893 | 3.39 | 11.58 | 3.0765 | 3.54 | 12.07 | 1.3029 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Zone Sensible CoolingCalculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 38646.65 | 38646.65 | 39.29 | 3.432 | 3.432 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00881 | 22.95 | 0.00546 | 0.425 | 0.00 |
CORE_MID | 28267.65 | 28267.65 | 28.74 | 2.508 | 2.508 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 08:00:00 | 24.00 | 24.00 | 0.00893 | 22.95 | 0.00546 | 0.425 | 0.00 |
CORE_TOP | 29851.79 | 29851.79 | 30.35 | 2.672 | 2.672 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:20:00 | 24.00 | 24.00 | 0.00890 | 33.60 | 0.00547 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 9557.26 | 9557.26 | 46.10 | 0.855 | 0.855 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 24.00 | 24.00 | 0.00867 | 33.75 | 0.00548 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 10809.14 | 10809.14 | 82.35 | 0.967 | 0.967 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:10:00 | 24.00 | 24.00 | 0.00859 | 26.18 | 0.00546 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 13025.16 | 13025.16 | 62.82 | 1.166 | 1.166 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:30:00 | 24.00 | 24.00 | 0.00862 | 33.53 | 0.00547 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 12607.50 | 12607.50 | 96.05 | 1.128 | 1.128 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 24.00 | 24.00 | 0.00858 | 31.83 | 0.00547 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 7336.07 | 7336.07 | 35.38 | 0.657 | 0.657 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 24.00 | 24.00 | 0.00878 | 33.90 | 0.00548 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 8815.01 | 8815.01 | 67.16 | 0.789 | 0.789 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:30:00 | 24.00 | 24.00 | 0.00864 | 27.02 | 0.00546 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 10239.86 | 10239.86 | 49.39 | 0.917 | 0.917 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:40:00 | 24.00 | 24.00 | 0.00870 | 33.65 | 0.00547 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 9750.83 | 9750.83 | 74.29 | 0.873 | 0.873 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:30:00 | 24.00 | 24.00 | 0.00863 | 31.09 | 0.00547 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 8266.02 | 8266.02 | 39.87 | 0.740 | 0.740 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | 24.00 | 24.00 | 0.00871 | 33.90 | 0.00548 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 10695.48 | 10695.48 | 81.48 | 0.957 | 0.957 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 09:00:00 | 24.00 | 24.00 | 0.00860 | 25.76 | 0.00546 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 11733.71 | 11733.71 | 56.59 | 1.050 | 1.050 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 13:20:00 | 24.00 | 24.00 | 0.00865 | 33.41 | 0.00547 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 11597.55 | 11597.55 | 88.36 | 1.038 | 1.038 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 17:00:00 | 24.00 | 24.00 | 0.00859 | 31.83 | 0.00547 | 0.057 | 0.00 |
Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
CORE_BOTTOM | 8524.37 | 8524.37 | 8.67 | 0.450 | 0.450 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:20:00 | 21.00 | 21.00 | 0.00800 | -17.90 | 0.00096 | 0.425 | 0.00 |
CORE_MID | 16617.30 | 16617.30 | 16.90 | 0.869 | 0.869 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -17.90 | 0.00096 | 0.425 | 0.00 |
CORE_TOP | 29153.84 | 29153.84 | 29.64 | 1.529 | 1.529 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00800 | -17.90 | 0.00096 | 0.425 | 0.00 |
PERIMETER_TOP_ZN_3 | 13240.78 | 13240.78 | 63.86 | 0.696 | 0.696 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00778 | -17.90 | 0.00096 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_2 | 8719.23 | 8719.23 | 66.43 | 0.458 | 0.458 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00778 | -17.90 | 0.00096 | 0.057 | 0.00 |
PERIMETER_TOP_ZN_1 | 13324.69 | 13324.69 | 64.27 | 0.700 | 0.700 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00778 | -17.90 | 0.00096 | 0.090 | 0.00 |
PERIMETER_TOP_ZN_4 | 8719.09 | 8719.09 | 66.43 | 0.458 | 0.458 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00778 | -17.90 | 0.00096 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_3 | 9851.38 | 9851.38 | 47.51 | 0.517 | 0.517 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00784 | -17.90 | 0.00096 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_2 | 6552.46 | 6552.46 | 49.92 | 0.344 | 0.344 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00784 | -17.90 | 0.00096 | 0.057 | 0.00 |
PERIMETER_BOT_ZN_1 | 9932.91 | 9932.91 | 47.91 | 0.522 | 0.522 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00784 | -17.90 | 0.00096 | 0.090 | 0.00 |
PERIMETER_BOT_ZN_4 | 6552.40 | 6552.40 | 49.92 | 0.344 | 0.344 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00784 | -17.90 | 0.00096 | 0.057 | 0.00 |
PERIMETER_MID_ZN_3 | 10330.27 | 10330.27 | 49.82 | 0.543 | 0.543 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00777 | -17.90 | 0.00096 | 0.090 | 0.00 |
PERIMETER_MID_ZN_2 | 6852.92 | 6852.92 | 52.21 | 0.360 | 0.360 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00777 | -17.90 | 0.00096 | 0.057 | 0.00 |
PERIMETER_MID_ZN_1 | 10401.96 | 10401.96 | 50.17 | 0.546 | 0.546 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00777 | -17.90 | 0.00096 | 0.090 | 0.00 |
PERIMETER_MID_ZN_4 | 6852.85 | 6852.85 | 52.21 | 0.360 | 0.360 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 21.00 | 21.00 | 0.00777 | -17.90 | 0.00096 | 0.057 | 0.00 |
Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
PACU_VAV_BOT | 5.91 | 5.91 | 2.17 | 2.17 | 5.9145 | 2.1650 | 5.9145 | 0.3661 | 0.3000 |
PACU_VAV_MID | 5.31 | 5.31 | 2.68 | 2.68 | 5.3055 | 2.6779 | 5.3055 | 0.5047 | 0.3000 |
PACU_VAV_TOP | 6.18 | 6.18 | 3.84 | 3.84 | 6.1830 | 3.8417 | 6.1830 | 0.6213 | 0.3000 |
Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
None |
Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | 17306.433 | 17306.433 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:20:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:20:00 | 17306.43 | 12207.01 | 0.450271 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00800000 | 41.9796 | 8524.37 | 0.00 | -999.00 | -999.00 |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | 23552.523 | 23552.523 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 23552.52 | 23552.52 | 0.868765 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00800000 | 41.9796 | 16617.30 | 0.00 | -999.00 | -999.00 |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | 41449.401 | 41449.401 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 41449.40 | 41449.40 | 1.528914 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00800000 | 41.9796 | 29153.84 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | 18866.391 | 18866.391 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 18866.39 | 18866.39 | 0.695911 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00778208 | 40.8533 | 13240.78 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | 12424.650 | 12424.650 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 12424.65 | 12424.65 | 0.458299 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00777948 | 40.8400 | 8719.23 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | 18986.184 | 18986.184 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 18986.18 | 18986.18 | 0.700329 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00778342 | 40.8603 | 13324.69 | 0.00 | -999.00 | -999.00 |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | 12424.437 | 12424.437 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 12424.44 | 12424.44 | 0.458291 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00777948 | 40.8400 | 8719.09 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | 14029.282 | 14029.282 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 14029.28 | 14029.28 | 0.517488 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00783770 | 41.1405 | 9851.38 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | 9332.443 | 9332.443 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 9332.44 | 9332.44 | 0.344239 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00783926 | 41.1486 | 6552.46 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | 14145.691 | 14145.691 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 14145.69 | 14145.69 | 0.521782 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00783940 | 41.1493 | 9932.91 | 0.00 | -999.00 | -999.00 |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | 9332.351 | 9332.351 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 9332.35 | 9332.35 | 0.344236 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00783926 | 41.1486 | 6552.40 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | 14711.884 | 14711.884 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 14711.88 | 14711.88 | 0.542666 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00776537 | 40.7663 | 10330.27 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | 9760.682 | 9760.682 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 9760.68 | 9760.68 | 0.360035 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00776524 | 40.7658 | 6852.92 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | 14814.241 | 14814.241 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 14814.24 | 14814.24 | 0.546442 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00776710 | 40.7753 | 10401.96 | 0.00 | -999.00 | -999.00 |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | 9760.584 | 9760.584 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 9760.58 | 9760.58 | 0.360031 | 12.80 | 9.74 | 0.00800000 | 40.00 | 18.76 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 0.0000 | 21.00 | 0.00776524 | 40.7657 | 6852.85 | 0.00 | -999.00 | -999.00 |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_BOT | 97905.894 | 78388.869 | 5.914495 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | 95327.57 | 95327.57 | 5.914495 | 25.60 | 14.58 | 0.00824653 | 10.62 | 9.11 | 0.00824653 | 33.90 | 0.00547527 | 15.07 | 16.1654 | 24.00 | 0.00878112 | 38.3549 | 66053.40 | 0.00 | 100954.12 | 71911.11 |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_BOT | 24025.313 | 24025.313 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:50:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 24025.31 | 24025.31 | 1.774349 | -0.99 | -1.39 | 0.00400621 | 12.80 | 9.74 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 53.8846 | 18.36 | 0.00757473 | 46.8720 | 13058.70 | 0.00 | -999.00 | -999.00 |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_MID | 87824.519 | 70317.163 | 5.305479 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 85511.69 | 85511.69 | 5.305479 | 25.79 | 14.60 | 0.00819832 | 10.62 | 9.06 | 0.00819832 | 33.90 | 0.00547527 | 15.07 | 18.0210 | 24.00 | 0.00879849 | 38.4294 | 59146.75 | 0.00 | 90558.87 | 64506.42 |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_MID | 25341.400 | 25341.400 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:30:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 25341.40 | 25341.40 | 1.591644 | -3.41 | -3.41 | 0.00356484 | 12.80 | 9.74 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 60.0700 | 17.67 | 0.00754151 | 48.7350 | 13368.67 | 0.00 | -999.00 | -999.00 |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoopHVAC | PACU_VAV_TOP | 102350.320 | 81947.322 | 6.182983 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | 99654.96 | 99654.96 | 6.182983 | 25.54 | 14.55 | 0.00824134 | 10.62 | 9.10 | 0.00824134 | 33.90 | 0.00547527 | 15.07 | 15.4634 | 24.00 | 0.00874948 | 38.2182 | 68828.17 | 0.00 | 105536.92 | 75175.50 |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoopHVAC | PACU_VAV_TOP | 24255.625 | 24255.625 | -999.0 | -999.0 | -999.000 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 02:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | 24255.62 | 24255.62 | 1.854895 | -0.51 | -0.97 | 0.00412936 | 12.80 | 9.74 | 0.00800000 | -17.90 | 0.00095524 | -17.90 | 51.5447 | 15.99 | 0.00763586 | 54.8931 | 13084.37 | 0.00 | -999.00 | -999.00 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
CoilsCoil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
CORE_BOTTOM VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_BOTTOM VAV BOX | CORE_BOTTOM | N/A | N/A | N/A | Yes | No | unknown | No | 17306.433 | 17306.433 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:20:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:20:00 | Sensible | 17306.43 | 12207.01 | 1.0000 | 0.44011164 | 0.450271 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 17306.43 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 21.00 | 0.00800000 | 21.00 | 0.00800000 | 41.9796 | 8524.37 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_MID VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_MID VAV BOX | CORE_MID | N/A | N/A | N/A | Yes | No | unknown | No | 23552.523 | 23552.523 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 23552.52 | 23552.52 | 1.0000 | 0.84916320 | 0.868765 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 23552.52 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.92 | 0.00800000 | 21.00 | 0.00800000 | 41.9796 | 16617.30 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
CORE_TOP VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | CORE_TOP VAV BOX | CORE_TOP | N/A | N/A | N/A | Yes | No | unknown | No | 41449.401 | 41449.401 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 41449.40 | 41449.40 | 1.0000 | 1.49441766 | 1.528914 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 41449.40 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00800000 | 21.00 | 0.00800000 | 41.9796 | 29153.84 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_3 VAV BOX | PERIMETER_TOP_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 18866.391 | 18866.391 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 18866.39 | 18866.39 | 1.0000 | 0.68020930 | 0.695911 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18866.39 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00778208 | 21.00 | 0.00778208 | 40.8533 | 13240.78 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_2 VAV BOX | PERIMETER_TOP_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 12424.650 | 12424.650 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 12424.65 | 12424.65 | 1.0000 | 0.44795862 | 0.458299 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12424.65 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00777948 | 21.00 | 0.00777948 | 40.8400 | 8719.23 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_1 VAV BOX | PERIMETER_TOP_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 18986.184 | 18986.184 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 18986.18 | 18986.18 | 1.0000 | 0.68452831 | 0.700329 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 18986.18 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00778342 | 21.00 | 0.00778342 | 40.8603 | 13324.69 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_TOP_ZN_4 VAV BOX | PERIMETER_TOP_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 12424.437 | 12424.437 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 12424.44 | 12424.44 | 1.0000 | 0.44795096 | 0.458291 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 12424.44 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00777948 | 21.00 | 0.00777948 | 40.8400 | 8719.09 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_3 VAV BOX | PERIMETER_BOT_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 14029.282 | 14029.282 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 14029.28 | 14029.28 | 1.0000 | 0.50581205 | 0.517488 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14029.28 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00783770 | 21.00 | 0.00783770 | 41.1405 | 9851.38 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_2 VAV BOX | PERIMETER_BOT_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 9332.443 | 9332.443 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 9332.44 | 9332.44 | 1.0000 | 0.33647211 | 0.344239 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9332.44 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00783926 | 21.00 | 0.00783926 | 41.1486 | 6552.46 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_1 VAV BOX | PERIMETER_BOT_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 14145.691 | 14145.691 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 14145.69 | 14145.69 | 1.0000 | 0.51000906 | 0.521782 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14145.69 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00783940 | 21.00 | 0.00783940 | 41.1493 | 9932.91 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_BOT_ZN_4 VAV BOX | PERIMETER_BOT_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 9332.351 | 9332.351 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 9332.35 | 9332.35 | 1.0000 | 0.33646879 | 0.344236 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9332.35 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00783926 | 21.00 | 0.00783926 | 41.1486 | 6552.40 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_3 VAV BOX | PERIMETER_MID_ZN_3 | N/A | N/A | N/A | Yes | No | unknown | No | 14711.884 | 14711.884 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 14711.88 | 14711.88 | 1.0000 | 0.53042262 | 0.542666 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14711.88 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00776537 | 21.00 | 0.00776537 | 40.7663 | 10330.27 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_2 VAV BOX | PERIMETER_MID_ZN_2 | N/A | N/A | N/A | Yes | No | unknown | No | 9760.682 | 9760.682 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 9760.68 | 9760.68 | 1.0000 | 0.35191185 | 0.360035 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9760.68 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00776524 | 21.00 | 0.00776524 | 40.7658 | 6852.92 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_1 VAV BOX | PERIMETER_MID_ZN_1 | N/A | N/A | N/A | Yes | No | unknown | No | 14814.241 | 14814.241 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 14814.24 | 14814.24 | 1.0000 | 0.53411299 | 0.546442 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 14814.24 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00776710 | 21.00 | 0.00776710 | 40.7753 | 10401.96 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL | Coil:Heating:Electric | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | PERIMETER_MID_ZN_4 VAV BOX | PERIMETER_MID_ZN_4 | N/A | N/A | N/A | Yes | No | unknown | No | 9760.584 | 9760.584 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | unknown | unknown | -999.0 | -999.0 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 9760.58 | 9760.58 | 1.0000 | 0.35190831 | 0.360031 | 12.80 | 9.74 | 0.00800000 | 33059.8 | 40.00 | 18.76 | 0.00800000 | 60796.0 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 9760.58 | -17.90 | 0.00095524 | -17.90 | 0.00000000 | 0.0000 | 20.95 | 0.00776524 | 21.00 | 0.00776524 | 40.7657 | 6852.85 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_BOT COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 97905.894 | 78388.869 | 5.914495 | -999.0 | -999.000 | -999.0000 | 1.10885 | 1.00000 | 1020.1699 | 1004.8586 | 0.9774 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.914495 | 5.78104992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:10:00 | Sensible | 95327.57 | 95327.57 | 0.9737 | 5.78104992 | 5.914495 | 25.60 | 14.58 | 0.00824653 | 46740.4 | 10.62 | 9.11 | 0.00824653 | 31457.1 | -999.0 | -999.00 | -999.00 | -999.00 | 12863.366 | 82464.21 | 33.90 | 0.00547527 | 15.07 | 0.95610000 | 16.1654 | 24.00 | 0.00878112 | 24.00 | 0.00878112 | 38.3549 | 66053.40 | 0.00 | 100954.12 | 71911.11 | 5.55274215 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.99 | 13.21 | 0.00913394 | 37141.4 | |
PACU_VAV_BOT HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_BOT | CORE_BOTTOM; PERIMETER_BOT_ZN_1; PERIMETER_BOT_ZN_2; PERIMETER_BOT_ZN_3; PERIMETER_BOT_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24025.313 | 24025.313 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PACU_VAV_BOT FAN | Fan:VariableVolume | 5.914495 | 5.78104992 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:50:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 24025.31 | 24025.31 | 1.0000 | 1.73431498 | 1.774349 | -0.99 | -1.39 | 0.00400621 | 9021.2 | 12.80 | 9.74 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24025.31 | -17.90 | 0.00095524 | -17.90 | 0.95610000 | 53.8846 | 18.78 | 0.00757119 | 18.36 | 0.00757473 | 46.8720 | 13058.70 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_MID COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 87824.519 | 70317.163 | 5.305479 | -999.0 | -999.000 | -999.0000 | 1.09583 | 1.00000 | 1020.0803 | 1004.8586 | 0.9774 | PACU_VAV_MID FAN | Fan:VariableVolume | 5.305479 | 5.18577492 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | Sensible | 85511.69 | 85511.69 | 0.9737 | 5.18577492 | 5.305479 | 25.79 | 14.60 | 0.00819832 | 46808.4 | 10.62 | 9.06 | 0.00819832 | 31335.5 | -999.0 | -999.00 | -999.00 | -999.00 | 11538.825 | 73972.86 | 33.90 | 0.00547527 | 15.07 | 0.95610000 | 18.0210 | 24.00 | 0.00879849 | 24.00 | 0.00879849 | 38.4294 | 59146.75 | 0.00 | 90558.87 | 64506.42 | 4.98097601 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.99 | 13.21 | 0.00913394 | 37141.4 | |
PACU_VAV_MID HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_MID | CORE_MID; PERIMETER_MID_ZN_1; PERIMETER_MID_ZN_2; PERIMETER_MID_ZN_3; PERIMETER_MID_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 25341.400 | 25341.400 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PACU_VAV_MID FAN | Fan:VariableVolume | 5.305479 | 5.18577492 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 05:30:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 25341.40 | 25341.40 | 1.0000 | 1.55573248 | 1.591644 | -3.41 | -3.41 | 0.00356484 | 5466.1 | 12.80 | 9.74 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 25341.40 | -17.90 | 0.00095524 | -17.90 | 0.95610000 | 60.0700 | 18.39 | 0.00749068 | 17.67 | 0.00754151 | 48.7350 | 13368.67 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | |
PACU_VAV_TOP COOLING COIL | Coil:Cooling:DX:TwoSpeed | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | unknown | No | 102350.320 | 81947.322 | 6.182983 | -999.0 | -999.000 | -999.0000 | 1.11341 | 1.00000 | 1020.1602 | 1004.8586 | 0.9774 | PACU_VAV_TOP FAN | Fan:VariableVolume | 6.182983 | 6.04347996 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:00:00 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN CLG .4% CONDNS DB=>MWB | 7/21 15:30:00 | Sensible | 99654.96 | 99654.96 | 0.9737 | 6.04347996 | 6.182983 | 25.54 | 14.55 | 0.00824134 | 46661.5 | 10.62 | 9.10 | 0.00824134 | 31444.1 | -999.0 | -999.00 | -999.00 | -999.00 | 13447.297 | 86207.66 | 33.90 | 0.00547527 | 15.07 | 0.95610000 | 15.4634 | 24.00 | 0.00874948 | 24.00 | 0.00874948 | 38.2182 | 68828.17 | 0.00 | 105536.92 | 75175.50 | 5.80480819 | 26.67 | 19.44 | 0.01118466 | 55322.4 | 13.99 | 13.21 | 0.00913394 | 37141.4 | |
PACU_VAV_TOP HEATING COIL | Coil:Heating:Fuel | AirLoop | AirLoopHVAC | PACU_VAV_TOP | CORE_TOP; PERIMETER_TOP_ZN_1; PERIMETER_TOP_ZN_2; PERIMETER_TOP_ZN_3; PERIMETER_TOP_ZN_4; | Coincident | HeatingDesignCapacity | N/A | Yes | No | unknown | No | 24255.625 | 24255.625 | -999.0 | -999.0 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 0.9774 | PACU_VAV_TOP FAN | Fan:VariableVolume | 6.182983 | 6.04347996 | -999.0000 | -999.0000 | -999.0 | -999.00 | -999.00 | -999.00 | -999.00 | -999.0000 | -999.0 | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 02:00:00 | unknown | unknown | DENVER-AURORA-BUCKLEY.AFB_CO_USA ANN HTG 99.6% CONDNS DB | 12/21 08:00:00 | Sensible | 24255.62 | 24255.62 | 1.0000 | 1.81304399 | 1.854895 | -0.51 | -0.97 | 0.00412936 | 9807.1 | 12.80 | 9.74 | 0.00800000 | 33059.8 | -999.0 | -999.00 | -999.00 | -999.00 | 0.000 | 24255.62 | -17.90 | 0.00095524 | -17.90 | 0.95610000 | 51.5447 | 17.98 | 0.00750586 | 15.99 | 0.00763586 | 54.8931 | 13084.37 | 0.00 | -999.00 | -999.00 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 | -999.00 | -999.00 | -999.0 | -999.0 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
EconomizerHigh Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
PACU_VAV_BOT_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 5.91 | - | |||
PACU_VAV_MID_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 5.31 | - | |||
PACU_VAV_TOP_OA_CONTROLLER | DifferentialDryBulb | 0.00 | 6.18 | - |
Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
CORE_BOTTOM | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_MID | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
CORE_TOP | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_3 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_2 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | PERIMETER_MID_ZN_2_OA_MULT | 1.00 | 1.00 | |
PERIMETER_MID_ZN_1 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 | ||
PERIMETER_MID_ZN_4 | PACU_VAV_MID_DCV | 0.000000 | 0.000432 | 0.000000 | 0.000000 | Flow/Area | 1.00 | 1.00 |
Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
CORE_BOTTOM | 1463.00 | 2776.50 | 36.50 |
CORE_MID | 1356.17 | 3592.67 | 338.67 |
CORE_TOP | 1945.83 | 3851.50 | 984.67 |
PERIMETER_TOP_ZN_3 | 3100.50 | 4046.00 | 1992.83 |
PERIMETER_TOP_ZN_2 | 3113.00 | 3587.17 | 1582.17 |
PERIMETER_TOP_ZN_1 | 3054.17 | 3128.17 | 1332.17 |
PERIMETER_TOP_ZN_4 | 3174.17 | 3674.17 | 1754.83 |
PERIMETER_BOT_ZN_3 | 2595.83 | 4091.33 | 1656.33 |
PERIMETER_BOT_ZN_2 | 2735.33 | 3444.83 | 1110.50 |
PERIMETER_BOT_ZN_1 | 2471.83 | 3096.50 | 869.50 |
PERIMETER_BOT_ZN_4 | 2638.17 | 3548.67 | 1174.00 |
PERIMETER_MID_ZN_3 | 2600.33 | 3895.50 | 1412.83 |
PERIMETER_MID_ZN_2 | 2419.33 | 2970.33 | 1092.50 |
PERIMETER_MID_ZN_1 | 2813.17 | 2841.83 | 930.17 |
PERIMETER_MID_ZN_4 | 2757.17 | 3465.50 | 1236.83 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 |
Facility | 4681.67 | 4476.50 | 2314.17 |
During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
CORE_BOTTOM | 0.00 | 0.17 | 0.00 | 0.00 |
CORE_MID | 0.17 | 0.00 | 0.17 | 0.00 |
CORE_TOP | 1.50 | 0.00 | 1.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 71.00 | 14.17 | 26.83 | 11.00 |
PERIMETER_TOP_ZN_2 | 53.50 | 46.50 | 8.17 | 42.67 |
PERIMETER_TOP_ZN_1 | 38.67 | 55.17 | 8.00 | 51.67 |
PERIMETER_TOP_ZN_4 | 53.17 | 44.50 | 11.17 | 30.50 |
PERIMETER_BOT_ZN_3 | 4.83 | 0.50 | 3.50 | 0.50 |
PERIMETER_BOT_ZN_2 | 1.50 | 33.00 | 0.00 | 32.50 |
PERIMETER_BOT_ZN_1 | 186.17 | 65.67 | 185.17 | 64.00 |
PERIMETER_BOT_ZN_4 | 1.67 | 30.00 | 0.00 | 20.83 |
PERIMETER_MID_ZN_3 | 9.00 | 5.17 | 3.50 | 4.17 |
PERIMETER_MID_ZN_2 | 7.67 | 43.50 | 0.83 | 42.17 |
PERIMETER_MID_ZN_1 | 4.50 | 66.83 | 0.50 | 65.50 |
PERIMETER_MID_ZN_4 | 7.17 | 39.00 | 1.17 | 28.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Facility | 261.33 | 211.17 | 207.17 | 187.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Average Outdoor Air During Occupied HoursAverage Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.74 | 52.94 | 2698.04 | 0.984 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.74 | 52.94 | 2698.04 | 0.679 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.74 | 52.94 | 2698.04 | 0.663 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.58 | 11.16 | 568.77 | 0.761 | 0.083 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.90 | 7.07 | 360.08 | 1.300 | 0.088 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.58 | 11.16 | 568.77 | 1.409 | 0.084 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.90 | 7.06 | 360.05 | 1.144 | 0.088 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.58 | 11.16 | 568.77 | 0.611 | 0.044 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.90 | 7.07 | 360.08 | 1.097 | 0.047 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.58 | 11.16 | 568.77 | 1.054 | 0.858 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.90 | 7.06 | 360.05 | 0.913 | 0.047 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.58 | 11.16 | 568.77 | 0.743 | 0.070 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.54 | 7.07 | 360.08 | 1.213 | 0.079 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.58 | 11.16 | 568.77 | 1.391 | 0.070 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.90 | 7.06 | 360.05 | 1.111 | 0.073 | 0.000 | 0.000 |
Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
CORE_BOTTOM | 21.74 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_MID | 21.74 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
CORE_TOP | 21.74 | 52.94 | 2698.04 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_3 | 4.58 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_2 | 2.90 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_1 | 4.58 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_TOP_ZN_4 | 2.90 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_3 | 4.58 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_2 | 2.90 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_1 | 4.58 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_BOT_ZN_4 | 2.90 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_3 | 4.58 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_2 | 2.54 | 7.07 | 360.08 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_1 | 4.58 | 11.16 | 568.77 | 0.000 | 0.000 | 0.000 | 0.000 |
PERIMETER_MID_ZN_4 | 2.90 | 7.06 | 360.05 | 0.000 | 0.000 | 0.000 | 0.000 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Mechanical Ventilation Parameters by ZoneAirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 21.74 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_MID | PACU_VAV_MID | 21.74 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
CORE_TOP | PACU_VAV_TOP | 21.74 | 52.94 | 2698.04 | 983.54 | 0.0000 | 0.425 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 4.58 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 2.90 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 4.58 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 2.90 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 4.58 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 2.90 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 4.58 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 2.90 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 4.58 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 2.54 | 7.07 | 360.08 | 131.26 | 0.0000 | 0.057 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 4.58 | 11.16 | 568.77 | 207.34 | 0.0000 | 0.090 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 2.90 | 7.06 | 360.05 | 131.25 | 0.0000 | 0.057 |
Total Facility | 109.75 | 268.17 | 13667.13 | 4982.19 | 0.0000 | 2.151 |
Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
CORE_BOTTOM | 15674652.61 | 0.00 | 15674652.61 | 0.00 | 15674652.61 | 13393058.27 | 5010.79 | 331.60 | 3417.61 | 64.04 |
CORE_MID | 10864204.75 | 0.00 | 10864204.75 | 0.00 | 10864204.75 | 13393058.27 | 5610.70 | 894.95 | 2254.35 | 96.31 |
CORE_TOP | 10650927.49 | 0.00 | 10650927.49 | 0.00 | 10650927.49 | 13393058.27 | 5687.36 | 762.61 | 2310.03 | 111.82 |
PERIMETER_TOP_ZN_3 | 2577652.55 | 0.00 | 2577652.55 | 579019.07 | 3156671.62 | 2823374.22 | 4733.18 | 619.83 | 3407.00 | 111.82 |
PERIMETER_TOP_ZN_2 | 2771405.36 | 0.00 | 2771405.36 | 386010.39 | 3157415.75 | 1787429.43 | 4581.04 | 558.28 | 3620.69 | 111.82 |
PERIMETER_TOP_ZN_1 | 4740775.50 | 0.00 | 4740775.50 | 579019.07 | 5319794.57 | 2823374.22 | 4340.07 | 734.08 | 3685.85 | 111.82 |
PERIMETER_TOP_ZN_4 | 2459812.67 | 0.00 | 2459812.67 | 386010.39 | 2845823.06 | 1787312.18 | 4611.21 | 840.93 | 3307.86 | 111.82 |
PERIMETER_BOT_ZN_3 | 2065813.57 | 0.00 | 2065813.57 | 307860.96 | 2373674.53 | 2823374.22 | 6293.98 | 339.22 | 2126.79 | 64.04 |
PERIMETER_BOT_ZN_2 | 2335923.41 | 0.00 | 2335923.41 | 205239.41 | 2541162.82 | 1787429.43 | 5480.03 | 344.22 | 2935.74 | 64.04 |
PERIMETER_BOT_ZN_1 | 3552693.60 | 0.00 | 3552693.60 | 3038318.74 | 6591012.34 | 2823374.22 | 5017.06 | 322.11 | 3420.83 | 64.04 |
PERIMETER_BOT_ZN_4 | 1952248.69 | 0.00 | 1952248.69 | 205239.41 | 2157488.10 | 1787312.18 | 5689.51 | 397.05 | 2673.44 | 64.04 |
PERIMETER_MID_ZN_3 | 2507241.41 | 0.00 | 2507241.41 | 481988.59 | 2989230.01 | 2823374.22 | 4924.86 | 770.56 | 3064.58 | 96.31 |
PERIMETER_MID_ZN_2 | 2592999.37 | 0.00 | 2592999.37 | 321323.80 | 2914323.17 | 1601953.02 | 4448.96 | 686.82 | 3624.22 | 1005.31 |
PERIMETER_MID_ZN_1 | 4672210.70 | 0.00 | 4672210.70 | 481988.59 | 5154199.29 | 2823374.22 | 4323.49 | 827.63 | 3608.88 | 96.31 |
PERIMETER_MID_ZN_4 | 2375034.81 | 0.00 | 2375034.81 | 321323.80 | 2696358.60 | 1787312.18 | 4708.64 | 821.82 | 3229.54 | 96.31 |
Total Facility | 71793596.50 | 0.00 | 71793596.50 | 7293342.22 | 79086938.72 | 67658168.57 | 6817.11 | 1354.34 | 4630.77 | 1092.51 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
CORE_BOTTOM | 0.7276 | 0.0000 | 0.7276 | 0.0000 | 0.7276 | 0.4247 | 2237.35 | 331.60 | 3374.05 |
CORE_MID | 0.5027 | 0.0000 | 0.5027 | 0.0000 | 0.5027 | 0.4247 | 2837.13 | 894.79 | 2211.09 |
CORE_TOP | 0.4914 | 0.0000 | 0.4914 | 0.0000 | 0.4914 | 0.4247 | 2928.13 | 762.61 | 2252.26 |
PERIMETER_TOP_ZN_3 | 0.1190 | 0.0000 | 0.1190 | 0.0131 | 0.1321 | 0.0895 | 1974.11 | 619.83 | 3349.06 |
PERIMETER_TOP_ZN_2 | 0.1286 | 0.0000 | 0.1286 | 0.0087 | 0.1373 | 0.0567 | 1821.94 | 558.28 | 3562.78 |
PERIMETER_TOP_ZN_1 | 0.2201 | 0.0000 | 0.2201 | 0.0131 | 0.2332 | 0.0895 | 1580.84 | 734.08 | 3628.08 |
PERIMETER_TOP_ZN_4 | 0.1132 | 0.0000 | 0.1132 | 0.0087 | 0.1219 | 0.0567 | 1852.14 | 840.93 | 3249.93 |
PERIMETER_BOT_ZN_3 | 0.0955 | 0.0000 | 0.0955 | 0.0070 | 0.1025 | 0.0895 | 3520.48 | 339.22 | 2083.29 |
PERIMETER_BOT_ZN_2 | 0.1085 | 0.0000 | 0.1085 | 0.0046 | 0.1131 | 0.0567 | 2706.62 | 344.22 | 2892.15 |
PERIMETER_BOT_ZN_1 | 0.1649 | 0.0000 | 0.1649 | 0.1346 | 0.2995 | 0.0895 | 2243.59 | 322.11 | 3377.31 |
PERIMETER_BOT_ZN_4 | 0.0903 | 0.0000 | 0.0903 | 0.0046 | 0.0949 | 0.0567 | 2916.12 | 397.05 | 2629.83 |
PERIMETER_MID_ZN_3 | 0.1161 | 0.0000 | 0.1161 | 0.0109 | 0.1270 | 0.0895 | 2151.29 | 770.40 | 3021.31 |
PERIMETER_MID_ZN_2 | 0.1200 | 0.0000 | 0.1200 | 0.0078 | 0.1277 | 0.0567 | 1675.55 | 686.60 | 2671.85 |
PERIMETER_MID_ZN_1 | 0.2173 | 0.0000 | 0.2173 | 0.0109 | 0.2281 | 0.0895 | 1549.92 | 827.47 | 3565.61 |
PERIMETER_MID_ZN_4 | 0.1098 | 0.0000 | 0.1098 | 0.0073 | 0.1171 | 0.0567 | 1935.26 | 821.63 | 3186.12 |
Total Facility | 3.3249 | 0.0000 | 3.3249 | 0.2312 | 3.5561 | 2.1513 | 4023.28 | 1354.10 | 4552.92 |
Mechanical Ventilation [m3] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
PACU_VAV_BOT | 24439967.34 | 0.00 | 24439967.34 | 22614548.33 | 4775.62 | 257.10 | 3727.28 | 64.04 |
PACU_VAV_MID | 21984966.49 | 0.00 | 21984966.49 | 22429071.92 | 5215.15 | 83.94 | 3460.91 | 96.31 |
PACU_VAV_TOP | 22165390.05 | 0.00 | 22165390.05 | 22614548.33 | 5185.90 | 123.76 | 3450.33 | 110.30 |
Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
PACU_VAV_BOT | 1.1339 | 0.0000 | 1.1339 | 0.7171 | 2002.18 | 257.10 | 3683.72 |
PACU_VAV_MID | 1.0187 | 0.0000 | 1.0187 | 0.7084 | 2441.34 | 83.80 | 3417.87 |
PACU_VAV_TOP | 1.0245 | 0.0000 | 1.0245 | 0.7171 | 2426.84 | 123.76 | 3392.40 |
No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
PACU_VAV_BOT | 0.00 | 916.45 | 2163.48 | 0.00 | 0.00 | 0.00 | 1785.30 | 0.00 | 0.00 | 0.00 |
PACU_VAV_MID | 0.00 | 382.09 | 2283.44 | 0.00 | 0.00 | 0.00 | 2267.50 | 0.00 | 0.00 | 0.00 |
PACU_VAV_TOP | 0.00 | 316.69 | 2317.02 | 0.00 | 0.00 | 0.00 | 2315.51 | 0.00 | 0.00 | 0.00 |
No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
PACU_VAV_BOT | 0.0000 | 0.9051 | 2.1756 | 0.0000 | 0.0000 | 0.0000 | 0.7517 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_MID | 0.0000 | 0.8980 | 1.8560 | 0.0000 | 0.0000 | 0.0000 | 0.7284 | 0.0000 | 0.0000 | 0.0000 |
PACU_VAV_TOP | 0.0000 | 0.8922 | 1.8602 | 0.0000 | 0.0000 | 0.0000 | 0.7349 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Surfaces by ClassTotal | Outdoors | |
Wall | 72 | 24 |
Floor | 30 | 4 |
Roof | 26 | 1 |
Internal Mass | 15 | 0 |
Building Detached Shading | 0 | 0 |
Fixed Detached Shading | 0 | 0 |
Window | 18 | 18 |
Door | 6 | 6 |
Glass Door | 0 | 0 |
Shading | 0 | 0 |
Overhang | 0 | 0 |
Fin | 0 | 0 |
Tubular Daylighting Device Dome | 0 | 0 |
Tubular Daylighting Device Diffuser | 0 | 0 |
Count | |
HVAC Air Loops | 3 |
Conditioned Zones | 18 |
Unconditioned Zones | 0 |
Supply Plenums | 0 |
Return Plenums | 3 |
Count | |
IDF Objects | 943 |
Defaulted Fields | 546 |
Fields with Defaults | 2233 |
Autosized Fields | 150 |
Autosizable Fields | 202 |
Autocalculated Fields | 155 |
Autocalculatable Fields | 276 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Annual and Peak Values - ElectricityElectricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
Electricity:Facility | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
Electricity:Building | 937.68 | 12146.72 | 14-MAY-17:20 | 69370.75 | 21-DEC-08:10 |
Electricity:Zone:CORE_BOTTOM | 291.77 | 4006.86 | 01-JAN-00:10 | 23121.21 | 02-JAN-08:10 |
Electricity:SpaceType:GENERAL | 937.68 | 12146.72 | 14-MAY-17:20 | 69370.75 | 21-DEC-08:10 |
InteriorLights:Electricity | 232.25 | 905.38 | 14-MAY-17:20 | 25003.79 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:CORE_BOTTOM | 55.60 | 211.73 | 01-JAN-00:10 | 4936.01 | 02-JAN-08:10 |
InteriorLights:Electricity:SpaceType:GENERAL | 232.25 | 905.38 | 14-MAY-17:20 | 25003.79 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity | 232.25 | 905.38 | 14-MAY-17:20 | 25003.79 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:CORE_BOTTOM | 55.60 | 211.73 | 01-JAN-00:10 | 4936.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL | 232.25 | 905.38 | 14-MAY-17:20 | 25003.79 | 02-JAN-16:50 |
Electricity:Zone:CORE_MID | 171.02 | 2043.28 | 01-JAN-00:10 | 11744.33 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_MID | 55.60 | 211.73 | 01-JAN-00:10 | 4936.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_MID | 55.60 | 211.73 | 01-JAN-00:10 | 4936.01 | 02-JAN-08:10 |
Electricity:Zone:CORE_TOP | 171.02 | 2043.28 | 01-JAN-00:10 | 11744.33 | 02-JAN-08:10 |
InteriorLights:Electricity:Zone:CORE_TOP | 55.60 | 211.73 | 01-JAN-00:10 | 4936.01 | 02-JAN-08:10 |
LightsWired:InteriorLights:Electricity:Zone:CORE_TOP | 55.60 | 211.73 | 01-JAN-00:10 | 4936.01 | 02-JAN-08:10 |
Electricity:Zone:PERIMETER_TOP_ZN_3 | 31.06 | 413.68 | 09-APR-17:10 | 2475.80 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 6.73 | 27.57 | 01-JAN-09:00 | 1040.56 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_3 | 6.73 | 27.57 | 01-JAN-09:00 | 1040.56 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_TOP_ZN_2 | 19.66 | 261.88 | 14-MAY-17:10 | 1567.33 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 4.25 | 17.46 | 01-JAN-07:50 | 658.76 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_2 | 4.25 | 17.46 | 01-JAN-07:50 | 658.76 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_TOP_ZN_1 | 30.97 | 413.67 | 12-MAR-17:10 | 2475.79 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 6.64 | 27.57 | 01-JAN-07:50 | 1040.56 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_1 | 6.64 | 27.57 | 01-JAN-07:50 | 1040.56 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_TOP_ZN_4 | 19.61 | 261.87 | 12-MAR-17:10 | 1567.28 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 4.20 | 17.46 | 01-JAN-09:00 | 658.71 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_TOP_ZN_4 | 4.20 | 17.46 | 01-JAN-09:00 | 658.71 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_BOT_ZN_3 | 31.05 | 413.68 | 09-APR-17:10 | 2475.80 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 6.72 | 27.57 | 01-JAN-09:00 | 1040.56 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_3 | 6.72 | 27.57 | 01-JAN-09:00 | 1040.56 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_BOT_ZN_2 | 19.65 | 261.88 | 14-MAY-17:10 | 1567.33 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 4.25 | 17.46 | 01-JAN-07:50 | 658.76 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_2 | 4.25 | 17.46 | 01-JAN-07:50 | 658.76 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_BOT_ZN_1 | 30.96 | 413.67 | 12-MAR-17:10 | 2475.79 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 6.63 | 27.57 | 01-JAN-07:50 | 1040.56 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_1 | 6.63 | 27.57 | 01-JAN-07:50 | 1040.56 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_BOT_ZN_4 | 19.60 | 261.87 | 12-MAR-17:10 | 1567.28 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 4.20 | 17.46 | 01-JAN-09:00 | 658.71 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_BOT_ZN_4 | 4.20 | 17.46 | 01-JAN-09:00 | 658.71 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_MID_ZN_3 | 31.06 | 413.68 | 09-APR-17:10 | 2475.80 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 6.73 | 27.57 | 01-JAN-09:00 | 1040.56 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_3 | 6.73 | 27.57 | 01-JAN-09:00 | 1040.56 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_MID_ZN_2 | 19.66 | 261.88 | 14-MAY-17:10 | 1567.33 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 4.25 | 17.46 | 01-JAN-07:50 | 658.76 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_2 | 4.25 | 17.46 | 01-JAN-07:50 | 658.76 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_MID_ZN_1 | 30.97 | 413.67 | 12-MAR-17:10 | 2475.79 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 6.64 | 27.57 | 01-JAN-07:50 | 1040.56 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_1 | 6.64 | 27.57 | 01-JAN-07:50 | 1040.56 | 02-JAN-16:50 |
Electricity:Zone:PERIMETER_MID_ZN_4 | 19.61 | 261.87 | 12-MAR-17:10 | 1567.28 | 02-JAN-16:50 |
InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 4.20 | 17.46 | 01-JAN-09:00 | 658.71 | 02-JAN-16:50 |
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_MID_ZN_4 | 4.20 | 17.46 | 01-JAN-09:00 | 658.71 | 02-JAN-16:50 |
InteriorEquipment:Electricity | 705.43 | 11241.34 | 01-JAN-00:10 | 45864.70 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 236.17 | 3795.13 | 01-JAN-00:10 | 18185.19 | 02-JAN-08:10 |
InteriorEquipment:Electricity:SpaceType:GENERAL | 705.43 | 11241.34 | 01-JAN-00:10 | 45864.70 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL | 584.69 | 9277.75 | 01-JAN-00:10 | 34487.83 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_MID | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_TOP | 115.43 | 1831.54 | 01-JAN-00:10 | 6808.32 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_TOP_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_BOT_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_3 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.25 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_2 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_1 | 24.33 | 386.10 | 01-JAN-00:10 | 1435.24 | 02-JAN-08:10 |
InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_MID_ZN_4 | 15.40 | 244.42 | 01-JAN-00:10 | 908.57 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLift:InteriorEquipment:Electricity:SpaceType:GENERAL | 120.10 | 1963.59 | 01-JAN-00:10 | 11290.62 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:Zone:CORE_BOTTOM | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
ElevatorLightsFan:InteriorEquipment:Electricity:SpaceType:GENERAL | 0.64 | 0.00 | 01-JAN-00:10 | 86.25 | 02-JAN-08:10 |
Electricity:HVAC | 421.59 | 168.34 | 01-JAN-00:10 | 172350.52 | 06-FEB-07:10 |
ExteriorEquipment:Electricity | 11.69 | 168.34 | 01-JAN-00:10 | 838.79 | 02-JAN-17:00 |
Transformer:ExteriorEquipment:Electricity | 11.69 | 168.34 | 01-JAN-00:10 | 838.79 | 02-JAN-17:00 |
ElectricityPurchased:Facility | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
ElectricityPurchased:Plant | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
Cogeneration:ElectricityPurchased | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
General:Cogeneration:ElectricityPurchased | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
ElectricityNet:Facility | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
ElectricityNet:Plant | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
Cogeneration:ElectricityNet | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
General:Cogeneration:ElectricityNet | 1410.20 | 12315.29 | 29-MAY-17:50 | 201790.88 | 06-FEB-07:10 |
Heating:Electricity | 117.95 | 0.00 | 01-JAN-00:10 | 166145.31 | 06-FEB-07:10 |
General:Heating:Electricity | 117.95 | 0.00 | 01-JAN-00:10 | 166145.31 | 06-FEB-07:10 |
Fans:Electricity | 114.80 | 0.00 | 01-JAN-00:10 | 35100.38 | 24-JUL-15:20 |
General:Fans:Electricity | 114.80 | 0.00 | 01-JAN-00:10 | 35100.38 | 24-JUL-15:20 |
ExteriorLights:Electricity | 50.78 | 0.00 | 01-JAN-07:30 | 5686.19 | 01-JAN-06:10 |
General:ExteriorLights:Electricity | 50.78 | 0.00 | 01-JAN-07:30 | 5686.19 | 01-JAN-06:10 |
Cooling:Electricity | 177.16 | 0.00 | 01-JAN-00:10 | 84899.31 | 26-JUN-15:10 |
General:Cooling:Electricity | 177.16 | 0.00 | 01-JAN-00:10 | 84899.31 | 26-JUN-15:10 |
Electricity:Plant | 0.15 | 0.00 | 01-JAN-00:10 | 6.85 | 06-JAN-12:10 |
Pumps:Electricity | 0.15 | 0.00 | 01-JAN-00:10 | 6.85 | 06-JAN-12:10 |
General:Pumps:Electricity | 0.15 | 0.00 | 01-JAN-00:10 | 6.85 | 06-JAN-12:10 |
WIRED_LTG_ELECTRICITY | 6.53 | 0.00 | 01-JAN-00:10 | 702.61 | 02-JAN-17:00 |
WIRED_INT_EQUIP | 585.33 | 9277.75 | 01-JAN-00:10 | 34574.08 | 02-JAN-08:10 |
Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
NaturalGas:Facility | 307.05 | 1886.44 | 10-FEB-06:10 | 101490.73 | 21-DEC-09:40 |
NaturalGas:HVAC | 173.29 | 0.00 | 01-JAN-00:10 | 92027.92 | 21-DEC-08:10 |
Heating:NaturalGas | 173.29 | 0.00 | 01-JAN-00:10 | 92027.92 | 21-DEC-08:10 |
General:Heating:NaturalGas | 173.29 | 0.00 | 01-JAN-00:10 | 92027.92 | 21-DEC-08:10 |
NaturalGas:Plant | 133.76 | 1886.44 | 06-JAN-05:10 | 10507.47 | 14-FEB-12:30 |
WaterSystems:NaturalGas | 133.76 | 1886.44 | 06-JAN-05:10 | 10507.47 | 14-FEB-12:30 |
Water Heater:WaterSystems:NaturalGas | 133.76 | 1886.44 | 06-JAN-05:10 | 10507.47 | 14-FEB-12:30 |
Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
Water:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterUse:WaterSystems:Water | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Facility | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
MainsWater:Plant | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
WaterUse:WaterSystems:MainsWater | 271.06 | 0.00 | 01-JAN-00:10 | 0.00 | 03-JAN-12:10 |
Water Heater:WaterSystems:Water | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Water Heater:WaterSystems:MainsWater | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
None |
Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
EnergyTransfer:Facility | 2103.07 | 0.00 | 01-JAN-00:10 | 418023.86 | 26-JUN-15:10 |
EnergyTransfer:Building | 1114.07 | 0.00 | 01-JAN-00:10 | 174366.54 | 26-JUN-15:10 |
EnergyTransfer:Zone:CORE_BOTTOM | 219.08 | 0.00 | 01-JAN-00:10 | 27773.79 | 05-SEP-08:00 |
Heating:EnergyTransfer | 119.09 | 0.00 | 01-JAN-00:10 | 157194.91 | 06-FEB-06:10 |
Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 3135.79 | 26-DEC-07:10 |
General:Heating:EnergyTransfer | 119.09 | 0.00 | 01-JAN-00:10 | 157194.91 | 06-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:CORE_BOTTOM | 0.00 | 0.00 | 01-JAN-00:10 | 3135.79 | 26-DEC-07:10 |
Cooling:EnergyTransfer | 994.98 | 0.00 | 01-JAN-00:10 | 174366.54 | 26-JUN-15:10 |
Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 219.08 | 0.00 | 01-JAN-00:10 | 27773.79 | 05-SEP-08:00 |
General:Cooling:EnergyTransfer | 994.98 | 0.00 | 01-JAN-00:10 | 174366.54 | 26-JUN-15:10 |
General:Cooling:EnergyTransfer:Zone:CORE_BOTTOM | 219.08 | 0.00 | 01-JAN-00:10 | 27773.79 | 05-SEP-08:00 |
EnergyTransfer:Zone:TOPFLOOR_PLENUM | 52.23 | 0.00 | 01-JAN-00:10 | 14613.78 | 22-DEC-06:20 |
Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 18.94 | 0.00 | 01-JAN-00:10 | 14613.78 | 22-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 18.94 | 0.00 | 01-JAN-00:10 | 14613.78 | 22-DEC-06:20 |
Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 33.28 | 0.00 | 01-JAN-00:10 | 12354.93 | 26-JUN-13:20 |
General:Cooling:EnergyTransfer:Zone:TOPFLOOR_PLENUM | 33.28 | 0.00 | 01-JAN-00:10 | 12354.93 | 26-JUN-13:20 |
EnergyTransfer:Zone:MIDFLOOR_PLENUM | 25.78 | 0.00 | 01-JAN-00:10 | 7091.33 | 06-FEB-07:10 |
Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 10.01 | 0.00 | 01-JAN-00:10 | 7091.33 | 06-FEB-07:10 |
General:Heating:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 10.01 | 0.00 | 01-JAN-00:10 | 7091.33 | 06-FEB-07:10 |
Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 15.77 | 0.00 | 01-JAN-00:10 | 5782.29 | 17-JUL-10:30 |
General:Cooling:EnergyTransfer:Zone:MIDFLOOR_PLENUM | 15.77 | 0.00 | 01-JAN-00:10 | 5782.29 | 17-JUL-10:30 |
EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 27.14 | 0.00 | 01-JAN-00:10 | 6103.64 | 17-JUL-12:20 |
Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 6.58 | 0.00 | 01-JAN-00:10 | 4051.65 | 06-FEB-09:10 |
General:Heating:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 6.58 | 0.00 | 01-JAN-00:10 | 4051.65 | 06-FEB-09:10 |
Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 20.56 | 0.00 | 01-JAN-00:10 | 6103.64 | 17-JUL-12:20 |
General:Cooling:EnergyTransfer:Zone:FIRSTFLOOR_PLENUM | 20.56 | 0.00 | 01-JAN-00:10 | 6103.64 | 17-JUL-12:20 |
EnergyTransfer:Zone:CORE_MID | 137.57 | 0.00 | 01-JAN-00:10 | 19797.82 | 17-JUL-07:20 |
Heating:EnergyTransfer:Zone:CORE_MID | 0.59 | 0.00 | 01-JAN-00:10 | 16639.49 | 26-DEC-07:10 |
General:Heating:EnergyTransfer:Zone:CORE_MID | 0.59 | 0.00 | 01-JAN-00:10 | 16639.49 | 26-DEC-07:10 |
Cooling:EnergyTransfer:Zone:CORE_MID | 136.98 | 0.00 | 01-JAN-00:10 | 19797.82 | 17-JUL-07:20 |
General:Cooling:EnergyTransfer:Zone:CORE_MID | 136.98 | 0.00 | 01-JAN-00:10 | 19797.82 | 17-JUL-07:20 |
EnergyTransfer:Zone:CORE_TOP | 131.99 | 0.00 | 01-JAN-00:10 | 28560.61 | 26-DEC-06:20 |
Heating:EnergyTransfer:Zone:CORE_TOP | 5.83 | 0.00 | 01-JAN-00:10 | 28560.61 | 26-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:CORE_TOP | 5.83 | 0.00 | 01-JAN-00:10 | 28560.61 | 26-DEC-06:20 |
Cooling:EnergyTransfer:Zone:CORE_TOP | 126.16 | 0.00 | 01-JAN-00:10 | 21038.29 | 17-JUL-14:00 |
General:Cooling:EnergyTransfer:Zone:CORE_TOP | 126.16 | 0.00 | 01-JAN-00:10 | 21038.29 | 17-JUL-14:00 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 42.66 | 0.00 | 01-JAN-00:10 | 9863.00 | 23-DEC-05:10 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 13.65 | 0.00 | 01-JAN-00:10 | 9863.00 | 23-DEC-05:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 13.65 | 0.00 | 01-JAN-00:10 | 9863.00 | 23-DEC-05:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 29.01 | 0.00 | 01-JAN-00:10 | 8043.73 | 17-JUL-13:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_3 | 29.01 | 0.00 | 01-JAN-00:10 | 8043.73 | 17-JUL-13:30 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 40.52 | 0.00 | 01-JAN-00:10 | 10113.38 | 17-JUL-08:30 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 7.24 | 0.00 | 01-JAN-00:10 | 8451.36 | 22-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 7.24 | 0.00 | 01-JAN-00:10 | 8451.36 | 22-DEC-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 33.28 | 0.00 | 01-JAN-00:10 | 10113.38 | 17-JUL-08:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_2 | 33.28 | 0.00 | 01-JAN-00:10 | 10113.38 | 17-JUL-08:30 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 69.04 | 0.00 | 01-JAN-00:10 | 14026.01 | 28-SEP-13:10 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 8.92 | 0.00 | 01-JAN-00:10 | 11908.53 | 06-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 8.92 | 0.00 | 01-JAN-00:10 | 11908.53 | 06-FEB-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 60.12 | 0.00 | 01-JAN-00:10 | 14026.01 | 28-SEP-13:10 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_1 | 60.12 | 0.00 | 01-JAN-00:10 | 14026.01 | 28-SEP-13:10 |
EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 39.08 | 0.00 | 01-JAN-00:10 | 10949.34 | 16-AUG-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 7.92 | 0.00 | 01-JAN-00:10 | 8485.33 | 22-DEC-06:20 |
General:Heating:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 7.92 | 0.00 | 01-JAN-00:10 | 8485.33 | 22-DEC-06:20 |
Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 31.16 | 0.00 | 01-JAN-00:10 | 10949.34 | 16-AUG-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_TOP_ZN_4 | 31.16 | 0.00 | 01-JAN-00:10 | 10949.34 | 16-AUG-16:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 30.78 | 0.00 | 01-JAN-00:10 | 6805.87 | 06-FEB-06:10 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 5.86 | 0.00 | 01-JAN-00:10 | 6805.87 | 06-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 5.86 | 0.00 | 01-JAN-00:10 | 6805.87 | 06-FEB-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 24.92 | 0.00 | 01-JAN-00:10 | 6541.41 | 17-JUL-13:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_3 | 24.92 | 0.00 | 01-JAN-00:10 | 6541.41 | 17-JUL-13:30 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 33.39 | 0.00 | 01-JAN-00:10 | 8196.05 | 17-JUL-08:30 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 2.52 | 0.00 | 01-JAN-00:10 | 5902.14 | 06-FEB-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 2.52 | 0.00 | 01-JAN-00:10 | 5902.14 | 06-FEB-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 30.87 | 0.00 | 01-JAN-00:10 | 8196.05 | 17-JUL-08:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_2 | 30.87 | 0.00 | 01-JAN-00:10 | 8196.05 | 17-JUL-08:30 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 61.75 | 0.00 | 01-JAN-00:10 | 13123.26 | 21-DEC-08:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 13.56 | 0.00 | 01-JAN-00:10 | 13123.26 | 21-DEC-08:00 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 13.56 | 0.00 | 01-JAN-00:10 | 13123.26 | 21-DEC-08:00 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 48.19 | 0.00 | 01-JAN-00:10 | 11646.57 | 16-AUG-12:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_1 | 48.19 | 0.00 | 01-JAN-00:10 | 11646.57 | 16-AUG-12:00 |
EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 30.03 | 0.00 | 01-JAN-00:10 | 8477.92 | 26-JUN-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 2.63 | 0.00 | 01-JAN-00:10 | 5895.98 | 06-FEB-07:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 2.63 | 0.00 | 01-JAN-00:10 | 5895.98 | 06-FEB-07:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 27.39 | 0.00 | 01-JAN-00:10 | 8477.92 | 26-JUN-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_BOT_ZN_4 | 27.39 | 0.00 | 01-JAN-00:10 | 8477.92 | 26-JUN-16:00 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 35.90 | 0.00 | 01-JAN-00:10 | 7687.56 | 13-FEB-06:10 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 5.50 | 0.00 | 01-JAN-00:10 | 7687.56 | 13-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 5.50 | 0.00 | 01-JAN-00:10 | 7687.56 | 13-FEB-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 30.39 | 0.00 | 01-JAN-00:10 | 7471.03 | 17-JUL-13:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_3 | 30.39 | 0.00 | 01-JAN-00:10 | 7471.03 | 17-JUL-13:30 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 35.87 | 0.00 | 01-JAN-00:10 | 9970.25 | 17-JUL-08:30 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 2.93 | 0.00 | 01-JAN-00:10 | 6142.73 | 06-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 2.93 | 0.00 | 01-JAN-00:10 | 6142.73 | 06-FEB-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 32.94 | 0.00 | 01-JAN-00:10 | 9970.25 | 17-JUL-08:30 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_2 | 32.94 | 0.00 | 01-JAN-00:10 | 9970.25 | 17-JUL-08:30 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 66.24 | 0.00 | 01-JAN-00:10 | 12952.28 | 28-SEP-13:20 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 3.30 | 0.00 | 01-JAN-00:10 | 9157.81 | 06-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 3.30 | 0.00 | 01-JAN-00:10 | 9157.81 | 06-FEB-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 62.95 | 0.00 | 01-JAN-00:10 | 12952.28 | 28-SEP-13:20 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_1 | 62.95 | 0.00 | 01-JAN-00:10 | 12952.28 | 28-SEP-13:20 |
EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 35.03 | 0.00 | 01-JAN-00:10 | 10314.82 | 16-AUG-16:00 |
Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 3.11 | 0.00 | 01-JAN-00:10 | 6183.24 | 06-FEB-06:10 |
General:Heating:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 3.11 | 0.00 | 01-JAN-00:10 | 6183.24 | 06-FEB-06:10 |
Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 31.92 | 0.00 | 01-JAN-00:10 | 10314.82 | 16-AUG-16:00 |
General:Cooling:EnergyTransfer:Zone:PERIMETER_MID_ZN_4 | 31.92 | 0.00 | 01-JAN-00:10 | 10314.82 | 16-AUG-16:00 |
PlantLoopHeatingDemand:Facility | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
PlantLoopHeatingDemand:Plant | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
WaterSystems:PlantLoopHeatingDemand | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
General:WaterSystems:PlantLoopHeatingDemand | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
EnergyTransfer:HVAC | 937.24 | 0.00 | 01-JAN-00:10 | 239491.27 | 26-JUN-15:10 |
HeatingCoils:EnergyTransfer | 256.58 | 0.00 | 01-JAN-00:10 | 223985.44 | 22-DEC-07:10 |
CoolingCoils:EnergyTransfer | 680.66 | 0.00 | 01-JAN-00:10 | 239491.27 | 26-JUN-15:10 |
EnergyTransfer:Plant | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
WaterSystems:EnergyTransfer | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
WaterUse:WaterSystems:EnergyTransfer | 51.76 | 0.00 | 01-JAN-00:10 | 6544.71 | 13-FEB-12:10 |
Water Heater:WaterSystems:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Annual Building Sensible Heat Gain ComponentsHVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
CORE_BOTTOM | 0.000 | 0.000 | 0.002 | -219.081 | 0.000 | 0.000 | 32.808 | 55.599 | 236.167 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -105.496 |
CORE_MID | 0.000 | 0.000 | 0.589 | -136.983 | 0.000 | 0.000 | 33.801 | 55.599 | 115.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -68.431 |
CORE_TOP | 0.000 | 0.000 | 5.828 | -126.157 | 0.000 | 0.000 | 34.532 | 55.599 | 115.425 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -85.227 |
PERIMETER_TOP_ZN_3 | 0.000 | 0.000 | 13.649 | -29.014 | 0.000 | 0.000 | 7.497 | 6.731 | 24.333 | 20.699 | 0.000 | 0.155 | 0.000 | 0.000 | -35.545 | 0.000 | -7.275 | -1.229 |
PERIMETER_TOP_ZN_2 | 0.000 | 0.000 | 7.238 | -33.279 | 0.000 | 0.000 | 4.611 | 4.254 | 15.404 | 46.346 | 0.000 | 0.100 | 0.001 | 0.000 | -22.974 | 0.000 | -4.980 | -16.719 |
PERIMETER_TOP_ZN_1 | 0.000 | 0.000 | 8.921 | -60.120 | 0.000 | 0.000 | 7.198 | 6.638 | 24.332 | 96.025 | 0.000 | 0.151 | 0.001 | 0.000 | -34.747 | 0.000 | -7.663 | -40.735 |
PERIMETER_TOP_ZN_4 | 0.000 | 0.000 | 7.921 | -31.157 | 0.000 | 0.000 | 4.676 | 4.203 | 15.403 | 42.575 | 0.000 | 0.100 | 0.000 | 0.000 | -23.605 | 0.000 | -4.996 | -15.123 |
PERIMETER_BOT_ZN_3 | 0.000 | 0.000 | 5.861 | -24.916 | 0.000 | 0.000 | 7.485 | 6.719 | 24.333 | 21.034 | 0.000 | 0.090 | 0.198 | 0.000 | -36.765 | 0.000 | -4.040 | -0.001 |
PERIMETER_BOT_ZN_2 | 0.000 | 0.000 | 2.517 | -30.874 | 0.000 | 0.000 | 4.578 | 4.248 | 15.404 | 46.507 | 0.000 | 0.055 | 0.003 | 0.000 | -24.310 | 0.000 | -2.831 | -15.294 |
PERIMETER_BOT_ZN_1 | 0.000 | 0.000 | 13.561 | -48.187 | 0.000 | 0.000 | 7.286 | 6.630 | 24.332 | 96.621 | 0.000 | 2.346 | 0.002 | 0.000 | -37.191 | 0.000 | -34.274 | -31.124 |
PERIMETER_BOT_ZN_4 | 0.000 | 0.000 | 2.631 | -27.394 | 0.000 | 0.000 | 4.630 | 4.197 | 15.403 | 42.788 | 0.000 | 0.055 | 0.001 | 0.000 | -24.998 | 0.000 | -2.838 | -14.474 |
PERIMETER_MID_ZN_3 | 0.000 | 0.000 | 5.504 | -30.392 | 0.000 | 0.000 | 7.413 | 6.731 | 24.333 | 20.458 | 0.000 | 0.132 | 9.687 | 0.000 | -37.481 | 0.000 | -6.385 | 0.000 |
PERIMETER_MID_ZN_2 | 0.000 | 0.000 | 2.934 | -32.936 | 0.000 | 0.000 | 3.371 | 4.254 | 15.404 | 46.073 | 0.000 | 0.083 | 0.000 | 0.000 | -24.176 | 0.000 | -4.368 | -10.639 |
PERIMETER_MID_ZN_1 | 0.000 | 0.000 | 3.296 | -62.946 | 0.000 | 0.000 | 7.123 | 6.638 | 24.332 | 95.756 | 0.000 | 0.128 | 0.004 | 0.000 | -36.569 | 0.000 | -6.714 | -31.045 |
PERIMETER_MID_ZN_4 | 0.000 | 0.000 | 3.107 | -31.924 | 0.000 | 0.000 | 4.623 | 4.203 | 15.403 | 42.425 | 0.000 | 0.084 | 0.000 | 0.000 | -24.879 | 0.000 | -4.379 | -8.664 |
TOPFLOOR_PLENUM | 18.944 | -33.282 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.157 | 25.360 | 0.000 | 0.000 | 0.000 | -11.179 | -0.001 |
MIDFLOOR_PLENUM | 10.007 | -15.769 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.194 | 16.701 | 0.000 | 0.000 | 0.000 | -11.133 | -0.000 |
FIRSTFLOOR_PLENUM | 6.584 | -20.558 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.151 | 22.806 | 0.000 | 0.000 | 0.000 | -8.983 | -0.000 |
Total Facility | 35.534 | -69.608 | 83.558 | -925.360 | 0.000 | 0.000 | 171.631 | 232.246 | 705.434 | 617.307 | 0.000 | 3.982 | 74.765 | 0.000 | -363.240 | 0.000 | -122.037 | -444.202 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 28-AUG-05:12 | 0.00 | 0.00 | 0.00 | -41927.10 | 0.00 | 0.00 | 313.67 | 548.43 | 4989.51 | 0.00 | 0.00 | 0.00 | 36075.49 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 05-SEP-05:12 | 0.00 | 0.00 | 0.00 | -31553.44 | 0.00 | 0.00 | 315.44 | 548.43 | 3025.92 | 0.00 | 0.00 | 0.00 | 27663.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 24-JUL-05:12 | 0.00 | 0.00 | 0.00 | -32727.77 | 0.00 | 0.00 | 322.37 | 548.43 | 3025.92 | 0.00 | 0.00 | 0.00 | 28831.05 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 16-JUL-14:32 | 0.00 | 0.00 | 0.00 | -11719.60 | 0.00 | 0.00 | 24.30 | 27.57 | 478.42 | 5402.69 | 0.00 | 397.71 | 5388.91 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 06-AUG-09:12 | 0.00 | 0.00 | 0.00 | -14025.96 | 0.00 | 0.00 | 12.79 | 17.46 | 302.86 | 10608.02 | 0.00 | 0.00 | 3108.66 | 0.00 | -0.00 | 0.00 | -23.83 | 0.00 |
PERIMETER_TOP_ZN_1 | 09-OCT-13:31 | 0.00 | 0.00 | 0.00 | -18919.28 | 0.00 | 0.00 | 19.74 | 27.57 | 478.41 | 16218.37 | 0.00 | 0.00 | 2280.28 | 0.00 | -0.00 | 0.00 | -105.10 | 0.00 |
PERIMETER_TOP_ZN_4 | 25-JUN-16:31 | 0.00 | 0.00 | 0.00 | -16932.13 | 0.00 | 0.00 | 9.37 | 17.46 | 302.86 | 11403.84 | 0.00 | 98.38 | 5100.22 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 16-JUL-14:21 | 0.00 | 0.00 | 0.00 | -8854.86 | 0.00 | 0.00 | 27.79 | 27.57 | 478.42 | 6033.89 | 0.00 | 217.54 | 2069.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 06-AUG-09:01 | 0.00 | 0.00 | 0.00 | -12045.78 | 0.00 | 0.00 | 14.88 | 17.46 | 302.86 | 11132.49 | 0.00 | 0.00 | 595.89 | 0.00 | -0.00 | 0.00 | -17.80 | 0.00 |
PERIMETER_BOT_ZN_1 | 09-OCT-13:31 | 0.00 | 0.00 | 0.00 | -14821.38 | 0.00 | 0.00 | 20.76 | 27.57 | 478.41 | 16280.63 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -54.86 | -1931.14 |
PERIMETER_BOT_ZN_4 | 10-SEP-17:11 | 0.00 | 0.00 | 0.00 | -13797.71 | 0.00 | 0.00 | 0.00 | 17.46 | 244.42 | 8590.09 | 0.00 | 10.58 | 4935.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 25-JUN-17:01 | 0.00 | 0.00 | 0.00 | -10154.60 | 0.00 | 0.00 | 0.00 | 27.57 | 386.10 | 3503.78 | 0.00 | 182.44 | 6054.71 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 06-AUG-09:01 | 0.00 | 0.00 | 0.00 | -15285.80 | 0.00 | 0.00 | 12.72 | 17.46 | 302.86 | 11038.55 | 0.00 | 0.00 | 3949.94 | 0.00 | -0.00 | 0.00 | -35.72 | 0.00 |
PERIMETER_MID_ZN_1 | 04-SEP-13:13 | 0.00 | 0.00 | 0.00 | -16408.36 | 0.00 | 0.00 | 20.62 | 27.57 | 478.41 | 13458.97 | 0.00 | 40.15 | 2382.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 25-JUN-16:21 | 0.00 | 0.00 | 0.00 | -16748.96 | 0.00 | 0.00 | 10.67 | 17.46 | 302.86 | 12242.50 | 0.00 | 51.15 | 4124.32 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 26-JUN-13:20 | 0.00 | -12354.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.71 | 12287.74 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 17-JUL-10:10 | 0.00 | -5961.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.10 | 5871.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 17-JUL-12:08 | 0.00 | -6685.26 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.74 | 6624.52 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
Total Facility | 17-JUL-06:03 | 0.00 | -8251.19 | 0.00 | -181603.52 | 0.00 | 0.00 | 3473.10 | 6557.23 | 21098.80 | 35376.84 | 0.00 | 0.00 | 124594.05 | 0.00 | 0.00 | 0.00 | -1245.30 | 0.00 |
Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
CORE_BOTTOM | 26-DEC-07:03 | 0.00 | 0.00 | 12543.21 | 0.00 | 0.00 | 0.00 | 902.78 | 1645.36 | 8796.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -23888.15 |
CORE_MID | 26-DEC-06:11 | 0.00 | 0.00 | 20852.21 | 0.00 | 0.00 | 0.00 | 501.77 | 548.43 | 3025.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -24928.33 |
CORE_TOP | 06-FEB-05:01 | 0.00 | 0.00 | 31599.69 | 0.00 | 0.00 | 0.00 | 0.00 | 211.73 | 2442.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | 0.00 | -34253.47 |
PERIMETER_TOP_ZN_3 | 24-DEC-03:32 | 0.00 | 0.00 | 11132.56 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 386.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3947.97 | 0.00 | -1569.26 | -6046.07 |
PERIMETER_TOP_ZN_2 | 24-DEC-03:32 | 0.00 | 0.00 | 12330.39 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2707.47 | 0.00 | -1063.03 | -8832.58 |
PERIMETER_TOP_ZN_1 | 24-DEC-04:52 | 0.00 | 0.00 | 14886.26 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 386.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3924.02 | 0.00 | -1322.04 | -10070.93 |
PERIMETER_TOP_ZN_4 | 24-DEC-03:32 | 0.00 | 0.00 | 13222.84 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2710.57 | 0.00 | -1067.71 | -9717.23 |
PERIMETER_BOT_ZN_3 | 13-FEB-05:01 | 0.00 | 0.00 | 7862.26 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3140.20 | 0.00 | -498.01 | -4783.50 |
PERIMETER_BOT_ZN_2 | 23-DEC-05:01 | 0.00 | 0.00 | 8988.33 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 244.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2979.43 | 0.00 | -549.87 | -5731.71 |
PERIMETER_BOT_ZN_1 | 21-DEC-08:00 | 0.00 | 0.00 | 13122.74 | 0.00 | 0.00 | 0.00 | 250.76 | 306.36 | 637.88 | 0.00 | 0.00 | 0.00 | 14211.72 | 0.00 | -4635.89 | 0.00 | -23893.58 | 0.00 |
PERIMETER_BOT_ZN_4 | 06-FEB-05:01 | 0.00 | 0.00 | 8946.01 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -2000.46 | 0.00 | -264.13 | -7035.56 |
PERIMETER_MID_ZN_3 | 24-DEC-06:41 | 0.00 | 0.00 | 9013.38 | 0.00 | 0.00 | 0.00 | 58.91 | 57.81 | 478.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4011.38 | 0.00 | -1456.86 | -4140.27 |
PERIMETER_MID_ZN_2 | 21-DEC-05:01 | 0.00 | 0.00 | 9703.31 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3177.76 | 0.00 | -583.97 | -6295.73 |
PERIMETER_MID_ZN_1 | 21-DEC-05:01 | 0.00 | 0.00 | 12483.94 | 0.00 | 0.00 | 0.00 | 0.00 | 44.64 | 514.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -4797.47 | 0.00 | -876.20 | -7369.70 |
PERIMETER_MID_ZN_4 | 21-DEC-05:01 | 0.00 | 0.00 | 9685.18 | 0.00 | 0.00 | 0.00 | 0.00 | 28.26 | 325.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -3182.18 | 0.00 | -584.42 | -6272.73 |
TOPFLOOR_PLENUM | 22-DEC-06:12 | 17650.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -368.01 | -17282.10 |
MIDFLOOR_PLENUM | 06-FEB-07:11 | 8494.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -306.18 | -8188.29 |
FIRSTFLOOR_PLENUM | 30-OCT-07:07 | 5021.41 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -0.00 | 0.00 | -143.10 | -4878.31 |
Total Facility | 26-DEC-06:11 | 4216.23 | 3132.27 | 173591.98 | -3132.27 | 0.00 | 0.00 | 2575.19 | 2778.13 | 17291.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | -11544.99 | 0.00 | -2508.42 | -186399.63 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
System Ventilation Requirements for CoolingSum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 6.6670 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.9145 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 6.2932 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.3055 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 6.7892 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 6.1830 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
PACU_VAV_BOT | 3.3335 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.0776 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_MID | 3.1466 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.0764 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
PACU_VAV_TOP | 3.3946 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 1.0741 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
CORE_BOTTOM | PACU_VAV_BOT | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_MID | PACU_VAV_MID | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
CORE_TOP | PACU_VAV_TOP | 0.000000 | 52.9387 | 0.000432 | 983.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | 0.000000 | 7.0652 | 0.000432 | 131.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | 0.000000 | 11.1599 | 0.000432 | 207.34 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | 0.000000 | 7.0647 | 0.000432 | 131.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
PACU_VAV_BOT | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_MID | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 | |
PACU_VAV_TOP | 0.00 | 0.000432 | 1660.7286 | 0.0000 | 0.0000 | 0.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 3.4321 | 3.4321 | 0.6384 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.5078 | 2.5078 | 0.6370 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 2.6721 | 2.6721 | 0.6359 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8554 | 0.8554 | 0.1343 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9675 | 0.9675 | 0.0851 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1658 | 1.1658 | 0.1341 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.1284 | 1.1284 | 0.0846 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.6566 | 0.6566 | 0.1346 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7890 | 0.7890 | 0.0852 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9165 | 0.9165 | 0.1347 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8728 | 0.8728 | 0.0847 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7399 | 0.7399 | 0.1347 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9573 | 0.9573 | 0.0852 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0502 | 1.0502 | 0.1344 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0380 | 1.0380 | 0.0851 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 6.6670 | 5.9145 | 6.6670 | 1.0776 | 0.0000 | 1.0000 |
PACU_VAV_MID | 6.2932 | 5.3055 | 6.2932 | 1.0764 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 6.7892 | 6.1830 | 6.7892 | 1.0741 | 0.0000 | 1.0000 |
AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
CORE_BOTTOM | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.7160 | 1.7160 | 0.6384 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_MID | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.2539 | 1.2539 | 0.6370 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
CORE_TOP | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.3360 | 1.3360 | 0.6359 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_3 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4277 | 0.4277 | 0.1343 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_2 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4837 | 0.4837 | 0.0851 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_1 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5829 | 0.5829 | 0.1341 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_TOP_ZN_4 | PACU_VAV_TOP | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5642 | 0.5642 | 0.0846 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_3 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3283 | 0.3283 | 0.1346 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_2 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3945 | 0.3945 | 0.0852 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_1 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4583 | 0.4583 | 0.1347 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_BOT_ZN_4 | PACU_VAV_BOT | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4364 | 0.4364 | 0.0847 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_3 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3699 | 0.3699 | 0.1347 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_2 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4787 | 0.4787 | 0.0852 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_1 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5251 | 0.5251 | 0.1344 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
PERIMETER_MID_ZN_4 | PACU_VAV_MID | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5190 | 0.5190 | 0.0851 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
PACU_VAV_BOT | 3.3335 | 1.0776 | 1.0776 | 1.0776 | 0.0000 | 1.0000 |
PACU_VAV_MID | 3.1466 | 1.0764 | 1.0764 | 1.0764 | 0.0000 | 1.0000 |
PACU_VAV_TOP | 3.3946 | 1.0741 | 1.0741 | 1.0741 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Sec1.1A-General InformationData | |
Weather File | RUNPERIOD 1 ** Denver-Aurora-Buckley AFB CO USA TMY3 WMO#=724695 |
Total gross floor area [m2] | 4982.19 |
Principal Heating Source | Natural Gas |
Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
CORE_BOTTOM | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_MID | 983.54 | 983.54 | 0.00 | 113.98 |
CORE_TOP | 983.54 | 983.54 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_TOP_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_2 | 131.26 | 131.26 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_BOT_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
PERIMETER_MID_ZN_3 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_2 | 131.26 | 131.26 | 0.00 | 96.54 |
PERIMETER_MID_ZN_1 | 207.34 | 207.34 | 0.00 | 113.98 |
PERIMETER_MID_ZN_4 | 131.25 | 131.25 | 0.00 | 113.98 |
TOPFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 1660.73 | 1660.73 | 0.00 | 0.00 |
Totals | 4982.19 | 4982.19 | 0.00 |
Data | |
Number of hours heating loads not met | 207.17 |
Number of hours cooling loads not met | 187.17 |
Number of hours not met | 394.33 |
Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
None |
Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
Heating -- General | 117.95 | 166145.31 | 173.29 | 92027.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Cooling -- General | 177.16 | 84899.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Lighting -- LightsWired | 232.25 | 25003.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Lighting -- General | 50.78 | 5686.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- MiscPlug | 584.69 | 34487.83 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLift | 120.10 | 11290.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Interior Equipment -- ElevatorLightsFan | 0.64 | 86.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Exterior Equipment -- Transformer | 11.69 | 838.79 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Fans -- General | 114.80 | 35100.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Pumps -- General | 0.15 | 6.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Rejection -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- WaterUse | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Water Systems -- Water Heater | 0.00 | 0.00 | 133.76 | 10507.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Process Subtotal [GJ] | Total Energy Use [GJ] | |
Electricity | 705.43 | 1410.20 |
Natural Gas | 0.00 | 307.05 |
Additional | 0.00 | 0.00 |
Total | 705.43 | 1717.25 |
Process Subtotal [$] | Total Energy Cost [$] | |
Electricity | 0.00 | |
Natural Gas | 0.00 | |
Additional | 0.00 | |
Total | 0.00 |
Rated Capacity [kW] | Annual Energy Generated [GJ] | |
Photovoltaic | 0.00 | 0.00 |
Wind | 0.00 | 0.00 |
Electricty [MJ/m2] | |
Interior Lighting (All) | 46.62 |
Space Heating | 23.67 |
Space Cooling | 35.56 |
Fans (All) | 23.04 |
Service Water Heating | 0.00 |
Receptacle Equipment | 141.59 |
Miscellaneous (All) | 283.05 |
Subtotal | 283.05 |
Natural Gas [MJ/m2] | |
Space Heating | 34.78 |
Service Water Heating | 26.85 |
Miscellaneous (All) | 61.63 |
Subtotal | 61.63 |
Additional [MJ/m2] | |
Subtotal | 0.00 |
Miscellaneous | 0.00 |
Percent [%] | |
Interior Lighting (All) | 13.52 |
Space Heating | 16.96 |
Space Cooling | 10.32 |
Fans (All) | 6.69 |
Service Water Heating | 7.79 |
Receptacle Equipment | 41.08 |
Miscellaneous | 3.65 |
Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
EXTERIOR_LIGHTING_SCHEDULE_A | 6570. | 6570. |
EXTERIOR_LIGHTING_SCHEDULE_B | 8103. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 | 4472. | 4472. |
EXTERIOR_LIGHTING_SCHEDULE_B_2016 | 7665. | 8760. |
EXTERIOR_LIGHTING_SCHEDULE_C_2016 | 6752. | 8760. |
ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_ALWAYS_ON | 8760. | 8760. |
EXTERIOR_LGT_189_1 | 6828. | 8760. |
ALWAYS_OFF | 0. | 0. |
LTG_SCH_OFFICE | 2460. | 8760. |
BLDG_EQUIP_SCH | 4095. | 8760. |
BLDG_OCC_SCH | 2528. | 5992. |
BLDG_OCC_SCH_W_SB | 1878. | 5056. |
BLDG_OCC_SCH_WO_SB | 2545. | 5992. |
BLDG_ELEVATORS | 2070. | 8760. |
ELEV_LIGHT_FAN_SCH_24_7 | 8760. | 8760. |
ELEV_LIGHT_FAN_SCH_ADD_DF | 1470. | 4212. |
BLDG_SWH_SCH | 1441. | 5992. |
WORK_EFF_SCH | 0. | 0. |
FAN_SCH | 8760. | 8760. |
REHEATCOILAVAILSCHED | 8760. | 8760. |
COOLINGCOILAVAILSCHED | 8760. | 8760. |
MINOA_MOTORIZEDDAMPER_SCHED | 4472. | 4472. |
MINOA_SCHED | 8760. | 8760. |
CORE_BOTTOM SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_BOTTOM SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_MID SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_MID SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
CORE_TOP SUB CAT LATENT FRACT SCHED | 438. | 8760. |
CORE_TOP SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_TOP_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_BOT_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_3 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_2 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_1 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT LATENT FRACT SCHED | 438. | 8760. |
PERIMETER_MID_ZN_4 SUB CAT SENSIBLE FRACT SCHED | 1752. | 8760. |
INFIL_SCH_PNNL | 5172. | 8760. |
INFIL_DOOR_OPENING_SCH | 1121. | 3380. |
PERIMETER_MID_ZN_2_OA_MULT | 7824. | 7824. |
PERIMETER_MID_ZN_2_MDP_SCH | 706. | 8760. |
First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
HTGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | January | 21.00 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM | CORE_BOTTOM DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
HTGSETP_SCH_YES_OPTIMUM_W_SB | PERIMETER_MID_ZN_2 DUAL SP CONTROL | January | 20.44 | 365 | 15.60 | 365 |
CLGSETP_SCH_YES_OPTIMUM_W_SB | PERIMETER_MID_ZN_2 DUAL SP CONTROL | July | 24.00 | 365 | 26.70 | 365 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Heat Index HoursSafe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8756.83 | 3.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8726.33 | 33.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8734.00 | 26.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8727.17 | 32.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8745.00 | 15.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8748.17 | 11.83 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8745.50 | 14.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8759.83 | 0.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8730.50 | 29.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8738.33 | 21.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8733.00 | 27.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8656.33 | 103.67 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8656.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 103.67 | 0.00 | 0.00 | 0.00 |
Average | 8742.28 | 17.72 | 0.00 | 0.00 | 0.00 |
Sum | 157361.00 | 319.00 | 0.00 | 0.00 | 0.00 |
Safe (≤ 26.7°C) [hr] | Caution (> 26.7, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2, ≤ 39.4°C) [hr] | Danger (> 39.4, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
CORE_BOTTOM | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128304.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Average | 34143.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Sum | 614580.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 8705.33 | 54.67 | 0.00 | 0.00 | 0.00 |
CORE_MID | 8731.17 | 28.83 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 8751.67 | 8.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 8745.83 | 14.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 8727.67 | 32.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 8737.50 | 22.50 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 8736.83 | 23.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 8740.33 | 19.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 8755.67 | 4.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 8745.33 | 14.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 8750.00 | 10.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 8725.83 | 34.17 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 8740.33 | 19.67 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 8738.33 | 21.67 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 8736.83 | 23.17 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 8755.17 | 4.83 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 8705.33 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 8760.00 | 54.67 | 0.00 | 0.00 | 0.00 |
Average | 8741.32 | 18.68 | 0.00 | 0.00 | 0.00 |
Sum | 157343.83 | 336.17 | 0.00 | 0.00 | 0.00 |
Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
CORE_BOTTOM | 128285.50 | 18.50 | 0.00 | 0.00 | 0.00 |
CORE_MID | 128297.67 | 6.33 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 128303.67 | 0.33 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_3 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_2 | 10134.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_1 | 24909.00 | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_MID_ZN_4 | 14016.00 | 0.00 | 0.00 | 0.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 128303.67 | 18.50 | 0.00 | 0.00 | 0.00 |
Average | 34141.94 | 1.40 | 0.00 | 0.00 | 0.00 |
Sum | 614554.83 | 25.17 | 0.00 | 0.00 | 0.00 |
SET ≤ 12.2°C Hours (°C) | SET ≤ 12.2°C OccupantHours (°C) | Longest SET ≤ 12.2°C Duration [hr] | Start Time of the Longest SET ≤ 12.2°C Duration | |
None |
SET > 30°C Hours (°C) | SET > 30°C OccupantHours (°C) | Longest SET > 30°C Duration [hr] | Start Time of the Longest SET > 30°C Duration | |
None |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
CO2 Level HoursSafe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-10-16 08:32:02
Illuminance Level HoursA Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 8760.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 8760.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 8760.00 | 0.00 |
Average | 0.00 | 0.00 | 5840.00 | 0.00 |
Sum | 0.00 | 0.00 | 105120.00 | 0.00 |
A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
CORE_BOTTOM | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_MID | 0.00 | 0.00 | 0.00 | 0.00 |
CORE_TOP | 0.00 | 0.00 | 0.00 | 0.00 |
PERIMETER_TOP_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_TOP_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_TOP_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_2 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_BOT_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_BOT_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
PERIMETER_MID_ZN_3 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_2 | 0.00 | 0.00 | 10134.00 | 0.00 |
PERIMETER_MID_ZN_1 | 0.00 | 0.00 | 24909.00 | 0.00 |
PERIMETER_MID_ZN_4 | 0.00 | 0.00 | 14016.00 | 0.00 |
TOPFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
MIDFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
FIRSTFLOOR_PLENUM | 0.00 | 0.00 | 0.00 | 0.00 |
Min | 0.00 | 0.00 | 0.00 | 0.00 |
Max | 0.00 | 0.00 | 24909.00 | 0.00 |
Average | 0.00 | 0.00 | 12759.33 | 0.00 |
Sum | 0.00 | 0.00 | 229668.00 | 0.00 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICEMEDIUM
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 5B
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_CO_DENVER
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | |
January | 0.846 |
February | -0.25 |
March | 4.824 |
April | 6.083 |
May | 13.735 |
June | 22.164 |
July | 22.707 |
August | 21.737 |
September | 18.538 |
October | 7.117 |
November | 3.031 |
December | -1.01 |
Annual Sum or Average | 10.017 |
Minimum of Months | -1.01 |
Maximum of Months | 22.707 |
Report: ZoneCoolingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.120065E+11 | 17847.82 | 26-JAN-16:40 | 6.67 | 2.08 | 0.196714E+10 | 2606.66 | 10-JAN-10:09 | 6.67 | 2.08 |
February | 0.106833E+11 | 17230.35 | 28-FEB-09:00 | 1.00 | 0.54 | 0.177513E+10 | 2606.65 | 08-FEB-14:09 | 1.00 | 0.54 |
March | 0.153688E+11 | 36950.23 | 15-MAR-06:02 | 10.00 | 2.57 | 0.214282E+10 | 2606.64 | 17-MAR-09:20 | 6.67 | 6.28 |
April | 0.137503E+11 | 19215.47 | 13-APR-08:00 | 11.00 | 4.63 | 0.190682E+10 | 2606.77 | 13-APR-13:00 | 15.00 | 9.82 |
May | 0.205618E+11 | 36272.35 | 22-MAY-06:03 | 11.17 | 10.50 | 0.207723E+10 | 2606.72 | 26-MAY-13:09 | 12.83 | 7.87 |
June | 0.259307E+11 | 40602.78 | 26-JUN-05:12 | 17.53 | 11.60 | 0.207181E+10 | 2606.69 | 08-JUN-13:09 | 17.53 | 11.60 |
July | 0.253000E+11 | 41593.93 | 24-JUL-05:12 | 18.00 | 14.77 | 0.192620E+10 | 2606.67 | 11-JUL-09:30 | 18.00 | 14.77 |
August | 0.271130E+11 | 41915.86 | 28-AUG-05:12 | 15.00 | 14.37 | 0.216194E+10 | 2606.70 | 10-AUG-09:50 | 15.00 | 14.37 |
September | 0.239710E+11 | 41163.82 | 05-SEP-05:12 | 14.20 | 8.43 | 0.191951E+10 | 2606.89 | 05-SEP-09:09 | 16.47 | 11.53 |
October | 0.187782E+11 | 38834.22 | 10-OCT-06:01 | 8.33 | 4.27 | 0.199053E+10 | 2606.65 | 03-OCT-13:20 | 8.33 | 4.27 |
November | 0.144815E+11 | 36778.23 | 09-NOV-07:01 | 10.17 | 5.62 | 0.196430E+10 | 2606.63 | 01-NOV-09:39 | 10.17 | 5.62 |
December | 0.111362E+11 | 16199.11 | 05-DEC-09:00 | 0.00 | -3.3 | 0.188245E+10 | 2606.63 | 18-DEC-10:20 | 3.33 | -0.7 |
Annual Sum or Average | 0.219081E+12 | 0.237859E+11 | ||||||||
Minimum of Months | 0.106833E+11 | 16199.11 | 0.00 | -3.3 | 0.177513E+10 | 2606.63 | 1.00 | -0.7 | ||
Maximum of Months | 0.271130E+11 | 41915.86 | 18.00 | 14.77 | 0.216194E+10 | 2606.89 | 18.00 | 14.77 |
Report: ZoneCoolingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.236115E+09 | 3269.06 | 20-JAN-15:05 | 19.67 | 6.93 | 0.00 | 0.00 | 01-JAN-00:10 | 19.67 | 6.93 |
February | 0.304902E+09 | 3095.25 | 18-FEB-14:30 | 19.50 | 7.87 | 0.00 | 0.00 | 01-FEB-00:10 | 19.50 | 7.87 |
March | 0.121151E+10 | 7249.90 | 14-MAR-14:05 | 23.00 | 7.59 | 0.00 | 0.00 | 01-MAR-00:10 | 23.00 | 7.59 |
April | 0.121545E+10 | 6348.91 | 21-APR-13:30 | 15.50 | 6.04 | 0.00 | 0.00 | 01-APR-00:10 | 15.50 | 6.04 |
May | 0.306045E+10 | 8986.18 | 31-MAY-14:30 | 28.00 | 14.75 | 0.00 | 0.00 | 01-MAY-00:10 | 28.00 | 14.75 |
June | 0.727955E+10 | 12354.93 | 26-JUN-13:20 | 36.97 | 15.36 | 0.00 | 0.00 | 01-JUN-00:10 | 36.97 | 15.36 |
July | 0.667611E+10 | 10863.58 | 17-JUL-14:00 | 35.00 | 14.93 | 0.00 | 0.00 | 01-JUL-00:10 | 35.00 | 14.93 |
August | 0.679917E+10 | 12178.53 | 16-AUG-15:00 | 36.00 | 16.15 | 0.00 | 0.00 | 01-AUG-00:10 | 36.00 | 16.15 |
September | 0.436062E+10 | 9212.40 | 12-SEP-14:20 | 29.40 | 13.78 | 0.00 | 0.00 | 01-SEP-00:10 | 29.40 | 13.78 |
October | 0.150336E+10 | 7156.11 | 11-OCT-15:00 | 26.00 | 9.46 | 0.00 | 0.00 | 01-OCT-00:10 | 26.00 | 9.46 |
November | 0.500193E+09 | 4333.08 | 09-NOV-13:05 | 20.00 | 8.90 | 0.00 | 0.00 | 01-NOV-00:10 | 20.00 | 8.90 |
December | 0.134758E+09 | 1963.94 | 01-DEC-14:40 | 21.33 | 7.55 | 0.00 | 0.00 | 01-DEC-00:10 | 21.33 | 7.55 |
Annual Sum or Average | 0.332822E+11 | 0.00 | ||||||||
Minimum of Months | 0.134758E+09 | 1963.94 | 15.50 | 6.04 | 0.00 | 0.00 | 15.50 | 6.04 | ||
Maximum of Months | 0.727955E+10 | 12354.93 | 36.97 | 16.15 | 0.00 | 0.00 | 36.97 | 16.15 |
Report: ZoneCoolingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 36295041.44 | 3038.74 | 05-JAN-05:01 | -17.0 | -17.0 | 0.00 | 0.00 | 01-JAN-00:10 | -17.0 | -17.0 |
February | 30168857.23 | 2396.95 | 10-FEB-06:01 | -8.2 | -9.1 | 0.00 | 0.00 | 01-FEB-00:10 | -8.2 | -9.1 |
March | 0.313047E+09 | 2762.44 | 15-MAR-16:00 | 19.00 | 5.38 | 0.00 | 0.00 | 01-MAR-00:10 | 19.00 | 5.38 |
April | 0.195435E+09 | 2906.52 | 15-APR-05:01 | -5.0 | -5.1 | 0.00 | 0.00 | 01-APR-00:10 | -5.0 | -5.1 |
May | 0.111595E+10 | 2838.89 | 18-MAY-15:00 | 23.00 | 11.61 | 0.00 | 0.00 | 01-MAY-00:10 | 23.00 | 11.61 |
June | 0.375134E+10 | 5676.64 | 26-JUN-15:20 | 39.20 | 15.68 | 0.00 | 0.00 | 01-JUN-00:10 | 39.20 | 15.68 |
July | 0.369291E+10 | 5961.45 | 17-JUL-10:10 | 34.17 | 14.38 | 0.00 | 0.00 | 01-JUL-00:10 | 34.17 | 14.38 |
August | 0.364651E+10 | 5105.49 | 21-AUG-14:40 | 27.00 | 14.47 | 0.00 | 0.00 | 01-AUG-00:10 | 27.00 | 14.47 |
September | 0.240049E+10 | 4931.67 | 05-SEP-15:40 | 24.60 | 13.98 | 0.00 | 0.00 | 01-SEP-00:10 | 24.60 | 13.98 |
October | 0.473515E+09 | 3305.03 | 11-OCT-16:00 | 24.00 | 8.61 | 0.00 | 0.00 | 01-OCT-00:10 | 24.00 | 8.61 |
November | 97292907.50 | 2510.55 | 30-NOV-05:02 | -12.8 | -13.4 | 0.00 | 0.00 | 01-NOV-00:10 | -12.8 | -13.4 |
December | 15728475.64 | 3492.94 | 20-DEC-05:01 | -19.0 | -19.2 | 0.00 | 0.00 | 01-DEC-00:10 | -19.0 | -19.2 |
Annual Sum or Average | 0.157687E+11 | 0.00 | ||||||||
Minimum of Months | 15728475.64 | 2396.95 | -19.0 | -19.2 | 0.00 | 0.00 | -19.0 | -19.2 | ||
Maximum of Months | 0.375134E+10 | 5961.45 | 39.20 | 15.68 | 0.00 | 0.00 | 39.20 | 15.68 |
Report: ZoneCoolingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.167729E+09 | 2750.10 | 06-JAN-05:01 | -7.8 | -7.9 | 0.00 | 0.00 | 01-JAN-00:10 | -7.8 | -7.9 |
February | 0.123820E+09 | 2568.10 | 02-FEB-06:01 | -9.2 | -9.2 | 0.00 | 0.00 | 01-FEB-00:10 | -9.2 | -9.2 |
March | 0.603620E+09 | 3092.00 | 15-MAR-16:00 | 19.00 | 5.38 | 0.00 | 0.00 | 01-MAR-00:10 | 19.00 | 5.38 |
April | 0.395794E+09 | 2160.91 | 26-APR-05:11 | 2.33 | 0.28 | 0.00 | 0.00 | 01-APR-00:10 | 2.33 | 0.28 |
May | 0.165401E+10 | 3088.39 | 18-MAY-15:10 | 22.33 | 11.65 | 0.00 | 0.00 | 01-MAY-00:10 | 22.33 | 11.65 |
June | 0.422873E+10 | 6650.85 | 26-JUN-12:08 | 36.18 | 15.20 | 0.00 | 0.00 | 01-JUN-00:10 | 36.18 | 15.20 |
July | 0.414387E+10 | 6685.25 | 17-JUL-12:08 | 36.00 | 14.76 | 0.00 | 0.00 | 01-JUL-00:10 | 36.00 | 14.76 |
August | 0.435800E+10 | 5256.22 | 21-AUG-15:00 | 26.00 | 14.34 | 0.00 | 0.00 | 01-AUG-00:10 | 26.00 | 14.34 |
September | 0.330811E+10 | 5208.83 | 05-SEP-16:00 | 24.40 | 14.03 | 0.00 | 0.00 | 01-SEP-00:10 | 24.40 | 14.03 |
October | 0.114808E+10 | 3936.55 | 11-OCT-16:20 | 23.33 | 8.54 | 0.00 | 0.00 | 01-OCT-00:10 | 23.33 | 8.54 |
November | 0.354966E+09 | 2167.15 | 08-NOV-15:50 | 18.17 | 7.79 | 0.00 | 0.00 | 01-NOV-00:10 | 18.17 | 7.79 |
December | 71045842.83 | 3001.59 | 21-DEC-05:01 | -18.2 | -18.4 | 0.00 | 0.00 | 01-DEC-00:10 | -18.2 | -18.4 |
Annual Sum or Average | 0.205578E+11 | 0.00 | ||||||||
Minimum of Months | 71045842.83 | 2160.91 | -18.2 | -18.4 | 0.00 | 0.00 | -18.2 | -18.4 | ||
Maximum of Months | 0.435800E+10 | 6685.25 | 36.18 | 15.20 | 0.00 | 0.00 | 36.18 | 15.20 |
Report: ZoneCoolingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.672718E+10 | 10121.53 | 25-JAN-16:20 | 13.67 | 4.08 | 0.179580E+10 | 2606.62 | 27-JAN-10:09 | 2.17 | 2.09 |
February | 0.593170E+10 | 9454.97 | 27-FEB-16:30 | 13.00 | 4.47 | 0.161697E+10 | 2606.64 | 28-FEB-10:20 | 2.67 | 1.45 |
March | 0.889355E+10 | 14172.49 | 15-MAR-16:00 | 19.00 | 5.38 | 0.201735E+10 | 2606.65 | 17-MAR-09:20 | 6.67 | 6.28 |
April | 0.785199E+10 | 12683.84 | 21-APR-14:00 | 15.00 | 5.55 | 0.179833E+10 | 2606.72 | 13-APR-13:00 | 15.00 | 5.55 |
May | 0.127752E+11 | 15168.51 | 18-MAY-06:03 | 15.50 | 9.12 | 0.205757E+10 | 2606.66 | 18-MAY-09:09 | 20.33 | 11.73 |
June | 0.183655E+11 | 29911.41 | 19-JUN-05:12 | 18.27 | 12.22 | 0.206870E+10 | 2606.68 | 08-JUN-13:09 | 18.27 | 12.22 |
July | 0.181146E+11 | 30382.33 | 10-JUL-05:12 | 17.33 | 9.81 | 0.192285E+10 | 2607.70 | 17-JUL-09:30 | 32.50 | 14.21 |
August | 0.187372E+11 | 30753.38 | 07-AUG-05:12 | 16.33 | 11.48 | 0.215842E+10 | 2606.67 | 10-AUG-09:50 | 25.33 | 13.99 |
September | 0.157201E+11 | 31554.50 | 05-SEP-05:12 | 14.20 | 8.43 | 0.191364E+10 | 2606.86 | 05-SEP-09:09 | 16.47 | 11.53 |
October | 0.102532E+11 | 27260.48 | 10-OCT-06:01 | 8.33 | 4.27 | 0.191717E+10 | 2606.65 | 03-OCT-13:09 | 8.33 | 4.27 |
November | 0.763068E+10 | 12368.22 | 08-NOV-16:30 | 15.50 | 6.83 | 0.183976E+10 | 2606.60 | 15-NOV-10:20 | 7.67 | 3.50 |
December | 0.598211E+10 | 8064.50 | 15-DEC-16:00 | 6.00 | 2.22 | 0.168696E+10 | 2606.61 | 05-DEC-10:20 | 6.00 | 2.22 |
Annual Sum or Average | 0.136983E+12 | 0.227935E+11 | ||||||||
Minimum of Months | 0.593170E+10 | 8064.50 | 6.00 | 2.22 | 0.161697E+10 | 2606.60 | 2.17 | 1.45 | ||
Maximum of Months | 0.187372E+11 | 31554.50 | 19.00 | 12.22 | 0.215842E+10 | 2607.70 | 32.50 | 14.21 |
Report: ZoneCoolingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.517101E+10 | 9215.56 | 20-JAN-16:30 | 15.00 | 6.47 | 0.167623E+10 | 2606.58 | 26-JAN-14:20 | 9.00 | 2.97 |
February | 0.460468E+10 | 8360.03 | 27-FEB-16:20 | 13.00 | 4.42 | 0.152724E+10 | 2606.58 | 27-FEB-14:20 | 13.00 | 4.42 |
March | 0.766197E+10 | 15161.74 | 15-MAR-15:20 | 19.67 | 5.62 | 0.193207E+10 | 2608.01 | 17-MAR-13:39 | 8.67 | 7.14 |
April | 0.702272E+10 | 14099.46 | 21-APR-14:00 | 15.00 | 5.55 | 0.173793E+10 | 2606.72 | 13-APR-13:00 | 15.00 | 5.55 |
May | 0.121413E+11 | 16172.75 | 31-MAY-16:00 | 28.00 | 14.86 | 0.203008E+10 | 2606.66 | 18-MAY-09:09 | 28.00 | 14.86 |
June | 0.189860E+11 | 32114.91 | 26-JUN-05:12 | 17.53 | 11.60 | 0.206701E+10 | 2606.68 | 08-JUN-13:09 | 17.53 | 11.60 |
July | 0.185837E+11 | 32725.81 | 24-JUL-05:12 | 18.00 | 14.77 | 0.192184E+10 | 2606.65 | 11-JUL-09:30 | 18.00 | 14.77 |
August | 0.188959E+11 | 32422.22 | 21-AUG-05:12 | 19.83 | 12.23 | 0.215617E+10 | 2606.66 | 10-AUG-09:50 | 19.83 | 12.23 |
September | 0.147065E+11 | 30159.38 | 05-SEP-06:02 | 13.90 | 7.58 | 0.190211E+10 | 2606.85 | 05-SEP-09:09 | 16.47 | 11.53 |
October | 0.820833E+10 | 15946.75 | 11-OCT-15:30 | 25.00 | 9.04 | 0.182992E+10 | 2606.63 | 03-OCT-13:20 | 25.00 | 9.04 |
November | 0.587455E+10 | 11525.16 | 08-NOV-16:00 | 18.00 | 7.82 | 0.171705E+10 | 2606.59 | 08-NOV-14:20 | 18.00 | 7.82 |
December | 0.430104E+10 | 6621.50 | 15-DEC-16:00 | 6.00 | 2.22 | 0.156406E+10 | 2606.50 | 15-DEC-14:00 | 6.00 | 2.22 |
Annual Sum or Average | 0.126158E+12 | 0.220617E+11 | ||||||||
Minimum of Months | 0.430104E+10 | 6621.50 | 6.00 | 2.22 | 0.152724E+10 | 2606.50 | 6.00 | 2.22 | ||
Maximum of Months | 0.189860E+11 | 32725.81 | 28.00 | 14.86 | 0.215617E+10 | 2608.01 | 28.00 | 14.86 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.454879E+09 | 1427.41 | 20-JAN-14:30 | 20.50 | 6.87 | 0.320934E+09 | 535.02 | 20-JAN-16:19 | 16.00 | 6.84 |
February | 0.396905E+09 | 1191.78 | 27-FEB-13:40 | 14.00 | 4.75 | 0.290648E+09 | 531.30 | 27-FEB-14:00 | 14.00 | 4.75 |
March | 0.103163E+10 | 3664.01 | 14-MAR-14:30 | 23.00 | 7.59 | 0.376987E+09 | 549.49 | 16-MAR-13:20 | 16.00 | 5.23 |
April | 0.115463E+10 | 3685.35 | 20-APR-13:30 | 21.50 | 8.83 | 0.345715E+09 | 549.51 | 13-APR-13:00 | 21.50 | 8.83 |
May | 0.294496E+10 | 5730.03 | 17-MAY-13:30 | 29.00 | 11.78 | 0.419206E+09 | 549.50 | 17-MAY-09:20 | 29.00 | 11.78 |
June | 0.602899E+10 | 11642.04 | 25-JUN-17:51 | 31.60 | 13.99 | 0.435680E+09 | 549.99 | 12-JUN-13:09 | 31.60 | 13.99 |
July | 0.586911E+10 | 11719.53 | 16-JUL-14:32 | 35.67 | 14.60 | 0.405228E+09 | 549.92 | 18-JUL-13:09 | 34.33 | 14.01 |
August | 0.534461E+10 | 8329.60 | 20-AUG-15:41 | 28.00 | 14.08 | 0.453267E+09 | 549.50 | 21-AUG-09:20 | 25.67 | 14.10 |
September | 0.359750E+10 | 7980.41 | 03-SEP-15:32 | 26.43 | 13.91 | 0.394931E+09 | 549.54 | 05-SEP-09:09 | 16.47 | 11.53 |
October | 0.126367E+10 | 4095.28 | 11-OCT-14:40 | 26.33 | 9.55 | 0.358931E+09 | 549.49 | 11-OCT-13:20 | 26.33 | 9.55 |
November | 0.632204E+09 | 2370.36 | 09-NOV-13:40 | 20.00 | 8.72 | 0.329756E+09 | 549.48 | 08-NOV-14:20 | 20.00 | 8.72 |
December | 0.295723E+09 | 1121.90 | 01-DEC-13:40 | 21.67 | 7.88 | 0.301979E+09 | 511.35 | 04-DEC-14:00 | 19.00 | 6.13 |
Annual Sum or Average | 0.290148E+11 | 0.443326E+10 | ||||||||
Minimum of Months | 0.295723E+09 | 1121.90 | 14.00 | 4.75 | 0.290648E+09 | 511.35 | 14.00 | 4.75 | ||
Maximum of Months | 0.602899E+10 | 11719.53 | 35.67 | 14.60 | 0.453267E+09 | 549.99 | 34.33 | 14.10 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.555681E+09 | 2635.54 | 20-JAN-09:50 | 13.33 | 4.49 | 0.222330E+09 | 347.87 | 11-JAN-10:20 | 13.33 | 4.49 |
February | 0.644215E+09 | 3685.78 | 27-FEB-09:20 | 9.33 | 2.70 | 0.206657E+09 | 347.88 | 23-FEB-10:20 | 9.33 | 2.70 |
March | 0.162217E+10 | 8013.30 | 12-MAR-09:32 | 14.67 | 5.41 | 0.260489E+09 | 347.88 | 27-MAR-09:20 | 1.33 | -0.7 |
April | 0.170348E+10 | 7247.06 | 21-APR-08:50 | 11.83 | 5.97 | 0.235136E+09 | 347.89 | 13-APR-13:00 | 11.83 | 5.97 |
May | 0.335342E+10 | 8096.68 | 28-MAY-09:32 | 13.33 | 8.91 | 0.272533E+09 | 347.90 | 17-MAY-09:09 | 13.33 | 8.91 |
June | 0.636307E+10 | 11119.78 | 11-JUN-09:02 | 20.37 | 10.85 | 0.276473E+09 | 348.71 | 27-JUN-09:00 | 26.60 | 12.07 |
July | 0.596535E+10 | 13969.47 | 16-JUL-09:12 | 33.33 | 14.70 | 0.257286E+09 | 348.76 | 18-JUL-09:00 | 31.00 | 14.50 |
August | 0.613863E+10 | 14025.56 | 06-AUG-09:12 | 25.67 | 15.47 | 0.287924E+09 | 348.63 | 31-AUG-09:50 | 26.67 | 13.56 |
September | 0.419527E+10 | 11498.22 | 04-SEP-09:22 | 25.25 | 13.40 | 0.253811E+09 | 347.92 | 06-SEP-09:30 | 25.75 | 13.14 |
October | 0.160969E+10 | 7884.34 | 01-OCT-09:13 | 13.33 | 7.78 | 0.239885E+09 | 347.88 | 03-OCT-13:09 | 12.17 | 8.60 |
November | 0.766762E+09 | 3672.12 | 07-NOV-09:10 | 14.00 | 4.09 | 0.225102E+09 | 347.88 | 14-NOV-10:20 | 3.33 | 2.24 |
December | 0.361622E+09 | 904.91 | 01-DEC-09:40 | 12.00 | 4.05 | 0.204774E+09 | 347.88 | 15-DEC-10:20 | 6.00 | 0.55 |
Annual Sum or Average | 0.332794E+11 | 0.294240E+10 | ||||||||
Minimum of Months | 0.361622E+09 | 904.91 | 9.33 | 2.70 | 0.204774E+09 | 347.87 | 1.33 | -0.7 | ||
Maximum of Months | 0.636307E+10 | 14025.56 | 33.33 | 15.47 | 0.287924E+09 | 348.76 | 31.00 | 14.50 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.377963E+10 | 13204.96 | 20-JAN-13:30 | 21.00 | 6.97 | 0.380370E+09 | 562.29 | 20-JAN-14:09 | 20.83 | 6.93 |
February | 0.349916E+10 | 16275.65 | 26-FEB-13:22 | 17.50 | 4.55 | 0.345272E+09 | 549.72 | 27-FEB-14:00 | 14.00 | 4.75 |
March | 0.409121E+10 | 17545.94 | 12-MAR-12:52 | 19.00 | 5.98 | 0.410435E+09 | 558.57 | 15-MAR-13:20 | 20.33 | 5.93 |
April | 0.265215E+10 | 9502.61 | 21-APR-13:10 | 15.83 | 6.37 | 0.362996E+09 | 549.53 | 13-APR-13:00 | 15.83 | 6.37 |
May | 0.408089E+10 | 8401.86 | 16-MAY-13:10 | 27.17 | 12.14 | 0.421744E+09 | 549.51 | 26-MAY-13:09 | 12.83 | 7.87 |
June | 0.691436E+10 | 15614.07 | 25-JUN-15:11 | 33.43 | 13.65 | 0.435102E+09 | 550.03 | 26-JUN-13:30 | 37.15 | 15.33 |
July | 0.698975E+10 | 16023.35 | 23-JUL-13:32 | 34.67 | 16.62 | 0.405136E+09 | 549.51 | 11-JUL-09:30 | 34.67 | 16.62 |
August | 0.820368E+10 | 16022.17 | 06-AUG-12:32 | 31.33 | 15.82 | 0.453919E+09 | 560.76 | 31-AUG-13:09 | 30.00 | 11.91 |
September | 0.746786E+10 | 17136.19 | 04-SEP-13:22 | 29.40 | 13.40 | 0.399692E+09 | 599.43 | 28-SEP-13:20 | 30.50 | 11.31 |
October | 0.539921E+10 | 18915.42 | 09-OCT-13:31 | 22.00 | 8.78 | 0.380813E+09 | 583.06 | 10-OCT-13:09 | 24.17 | 8.07 |
November | 0.416491E+10 | 18321.08 | 05-NOV-13:51 | 21.00 | 6.36 | 0.380205E+09 | 566.98 | 07-NOV-14:09 | 22.00 | 7.34 |
December | 0.287782E+10 | 16953.25 | 17-DEC-13:12 | 18.00 | 5.78 | 0.357032E+09 | 549.54 | 15-DEC-14:50 | 18.00 | 5.78 |
Annual Sum or Average | 0.601206E+11 | 0.473272E+10 | ||||||||
Minimum of Months | 0.265215E+10 | 8401.86 | 15.83 | 4.55 | 0.345272E+09 | 549.51 | 12.83 | 4.75 | ||
Maximum of Months | 0.820368E+10 | 18915.42 | 34.67 | 16.62 | 0.453919E+09 | 599.43 | 37.15 | 16.62 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.718004E+09 | 5031.72 | 20-JAN-15:40 | 18.67 | 7.30 | 0.217869E+09 | 347.83 | 18-JAN-14:00 | 18.67 | 7.30 |
February | 0.778027E+09 | 5388.12 | 17-FEB-16:30 | 13.50 | 6.66 | 0.198154E+09 | 347.84 | 22-FEB-14:20 | 8.00 | 3.90 |
March | 0.167518E+10 | 15972.37 | 12-MAR-16:12 | 18.00 | 5.71 | 0.245950E+09 | 347.84 | 16-MAR-13:20 | 16.00 | 5.23 |
April | 0.157282E+10 | 8602.23 | 07-APR-16:00 | 21.00 | 8.12 | 0.222998E+09 | 347.86 | 13-APR-13:00 | 15.00 | 9.82 |
May | 0.306822E+10 | 9552.87 | 28-MAY-15:23 | 20.00 | 9.91 | 0.266104E+09 | 347.85 | 17-MAY-09:20 | 20.00 | 9.91 |
June | 0.583250E+10 | 16932.14 | 25-JUN-16:31 | 32.70 | 13.89 | 0.275714E+09 | 347.86 | 20-JUN-13:00 | 32.70 | 13.89 |
July | 0.513511E+10 | 16617.77 | 02-JUL-17:01 | 28.00 | 12.40 | 0.256561E+09 | 347.86 | 11-JUL-09:30 | 25.50 | 13.66 |
August | 0.528981E+10 | 16249.56 | 13-AUG-16:42 | 22.17 | 9.87 | 0.287224E+09 | 347.86 | 21-AUG-09:20 | 25.67 | 14.10 |
September | 0.380218E+10 | 16522.30 | 10-SEP-16:01 | 31.92 | 12.68 | 0.250913E+09 | 347.88 | 05-SEP-09:09 | 31.92 | 12.68 |
October | 0.190466E+10 | 16790.50 | 09-OCT-16:11 | 21.67 | 8.64 | 0.231346E+09 | 347.85 | 11-OCT-13:20 | 26.33 | 9.54 |
November | 0.928514E+09 | 7533.69 | 05-NOV-15:53 | 19.00 | 5.64 | 0.220102E+09 | 347.84 | 09-NOV-14:20 | 19.33 | 8.45 |
December | 0.452264E+09 | 3757.73 | 01-DEC-15:30 | 19.50 | 7.14 | 0.203523E+09 | 347.84 | 15-DEC-14:00 | 9.00 | 3.00 |
Annual Sum or Average | 0.311573E+11 | 0.287646E+10 | ||||||||
Minimum of Months | 0.452264E+09 | 3757.73 | 13.50 | 5.64 | 0.198154E+09 | 347.83 | 8.00 | 3.00 | ||
Maximum of Months | 0.583250E+10 | 16932.14 | 32.70 | 13.89 | 0.287224E+09 | 347.88 | 32.70 | 14.10 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.480335E+09 | 1295.42 | 20-JAN-14:10 | 20.83 | 6.93 | 0.318585E+09 | 483.26 | 25-JAN-14:00 | 14.00 | 4.48 |
February | 0.358293E+09 | 1181.13 | 22-FEB-13:05 | 8.00 | 3.60 | 0.286693E+09 | 485.99 | 27-FEB-14:00 | 14.00 | 4.75 |
March | 0.808216E+09 | 1732.56 | 14-MAR-15:00 | 23.00 | 7.59 | 0.366563E+09 | 549.48 | 16-MAR-13:20 | 16.00 | 5.23 |
April | 0.933752E+09 | 1573.76 | 20-APR-13:30 | 21.50 | 8.83 | 0.337952E+09 | 549.49 | 13-APR-13:20 | 21.50 | 8.83 |
May | 0.204808E+10 | 3893.86 | 17-MAY-13:30 | 29.00 | 11.78 | 0.418803E+09 | 549.50 | 18-MAY-09:20 | 20.67 | 11.73 |
June | 0.466405E+10 | 6937.10 | 26-JUN-06:03 | 19.77 | 12.60 | 0.435432E+09 | 549.69 | 13-JUN-13:20 | 19.77 | 12.60 |
July | 0.466163E+10 | 8854.88 | 16-JUL-14:21 | 35.50 | 14.51 | 0.404921E+09 | 549.59 | 18-JUL-13:00 | 31.00 | 15.59 |
August | 0.455774E+10 | 5481.50 | 21-AUG-14:00 | 29.00 | 14.55 | 0.454014E+09 | 549.50 | 21-AUG-09:20 | 29.00 | 14.55 |
September | 0.358118E+10 | 6468.46 | 11-SEP-06:03 | 19.00 | 9.04 | 0.400337E+09 | 549.54 | 05-SEP-09:09 | 19.00 | 9.04 |
October | 0.149899E+10 | 3399.16 | 11-OCT-14:30 | 26.50 | 9.60 | 0.376601E+09 | 549.49 | 03-OCT-13:20 | 26.50 | 9.60 |
November | 0.876781E+09 | 2024.34 | 09-NOV-13:30 | 20.00 | 8.78 | 0.339098E+09 | 549.49 | 09-NOV-10:20 | 20.00 | 8.78 |
December | 0.447187E+09 | 1190.82 | 03-DEC-15:23 | 17.00 | 6.47 | 0.306103E+09 | 502.69 | 04-DEC-14:00 | 19.00 | 6.13 |
Annual Sum or Average | 0.249162E+11 | 0.444510E+10 | ||||||||
Minimum of Months | 0.358293E+09 | 1181.13 | 8.00 | 3.60 | 0.286693E+09 | 483.26 | 14.00 | 4.48 | ||
Maximum of Months | 0.466405E+10 | 8854.88 | 35.50 | 14.55 | 0.454014E+09 | 549.69 | 31.00 | 15.59 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.590409E+09 | 1787.59 | 20-JAN-09:50 | 13.33 | 4.49 | 0.224091E+09 | 347.87 | 24-JAN-10:20 | 12.00 | 3.75 |
February | 0.622393E+09 | 3067.61 | 27-FEB-08:35 | 7.67 | 2.12 | 0.206104E+09 | 347.88 | 17-FEB-10:20 | 7.67 | 2.12 |
March | 0.134186E+10 | 4699.91 | 15-MAR-09:10 | 14.17 | 4.19 | 0.260942E+09 | 347.88 | 17-MAR-09:20 | 6.67 | 6.28 |
April | 0.140384E+10 | 4981.75 | 21-APR-09:00 | 12.00 | 5.98 | 0.236117E+09 | 347.89 | 13-APR-13:00 | 12.00 | 5.98 |
May | 0.264771E+10 | 6593.24 | 11-MAY-06:03 | 8.33 | 4.35 | 0.273424E+09 | 347.90 | 31-MAY-09:00 | 25.00 | 13.24 |
June | 0.550723E+10 | 8413.53 | 08-JUN-06:02 | 14.77 | 8.93 | 0.276620E+09 | 348.56 | 29-JUN-09:09 | 28.58 | 13.43 |
July | 0.520386E+10 | 11980.14 | 16-JUL-09:01 | 33.17 | 14.76 | 0.257414E+09 | 348.33 | 18-JUL-09:00 | 31.00 | 14.50 |
August | 0.574872E+10 | 12044.48 | 06-AUG-09:01 | 25.33 | 15.45 | 0.288415E+09 | 348.29 | 31-AUG-09:50 | 26.67 | 13.56 |
September | 0.441060E+10 | 11008.17 | 04-SEP-09:01 | 24.68 | 13.41 | 0.255504E+09 | 348.39 | 08-SEP-09:50 | 25.82 | 12.10 |
October | 0.192861E+10 | 7139.78 | 09-OCT-10:12 | 16.00 | 9.11 | 0.248932E+09 | 347.88 | 03-OCT-09:20 | 16.00 | 9.11 |
November | 0.989505E+09 | 3449.06 | 07-NOV-08:25 | 12.00 | 3.43 | 0.234873E+09 | 347.87 | 14-NOV-10:20 | 3.33 | 2.24 |
December | 0.479744E+09 | 1287.40 | 18-DEC-08:45 | -0.5 | -2.6 | 0.212190E+09 | 347.88 | 01-DEC-10:20 | -0.5 | -2.6 |
Annual Sum or Average | 0.308745E+11 | 0.297462E+10 | ||||||||
Minimum of Months | 0.479744E+09 | 1287.40 | -0.5 | -2.6 | 0.206104E+09 | 347.87 | -0.5 | -2.6 | ||
Maximum of Months | 0.574872E+10 | 12044.48 | 33.17 | 15.45 | 0.288415E+09 | 348.56 | 31.00 | 14.50 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.249848E+10 | 11194.32 | 22-JAN-14:53 | 8.00 | 4.11 | 0.369737E+09 | 550.37 | 20-JAN-14:09 | 8.00 | 4.11 |
February | 0.197644E+10 | 10682.35 | 26-FEB-13:02 | 17.83 | 4.74 | 0.328432E+09 | 550.29 | 27-FEB-14:00 | 14.00 | 4.75 |
March | 0.242369E+10 | 13252.95 | 12-MAR-12:52 | 19.00 | 5.98 | 0.396318E+09 | 551.23 | 13-MAR-13:00 | 23.00 | 7.20 |
April | 0.143690E+10 | 5832.51 | 12-APR-13:30 | 21.00 | 7.78 | 0.346936E+09 | 549.52 | 13-APR-13:00 | 15.00 | 9.82 |
May | 0.238390E+10 | 6849.54 | 16-MAY-12:00 | 27.00 | 11.84 | 0.409156E+09 | 549.52 | 26-MAY-13:09 | 12.83 | 7.87 |
June | 0.590554E+10 | 11478.16 | 26-JUN-12:00 | 36.10 | 15.16 | 0.433652E+09 | 606.60 | 26-JUN-12:09 | 36.18 | 15.20 |
July | 0.600725E+10 | 12242.29 | 16-JUL-14:21 | 35.50 | 14.51 | 0.403860E+09 | 606.71 | 17-JUL-12:09 | 36.00 | 14.76 |
August | 0.767306E+10 | 13051.79 | 27-AUG-12:32 | 25.33 | 15.15 | 0.453833E+09 | 619.35 | 16-AUG-12:09 | 25.33 | 15.15 |
September | 0.746720E+10 | 13454.24 | 04-SEP-13:01 | 29.40 | 13.49 | 0.401344E+09 | 614.37 | 28-SEP-12:09 | 30.08 | 11.35 |
October | 0.481662E+10 | 14818.35 | 09-OCT-13:31 | 22.00 | 8.78 | 0.384148E+09 | 614.92 | 10-OCT-13:39 | 24.67 | 8.45 |
November | 0.341303E+10 | 13272.63 | 05-NOV-13:22 | 21.00 | 6.47 | 0.373579E+09 | 584.74 | 07-NOV-14:09 | 22.00 | 7.34 |
December | 0.218523E+10 | 13507.32 | 17-DEC-14:42 | 17.58 | 5.66 | 0.344028E+09 | 549.75 | 15-DEC-14:00 | 17.58 | 5.66 |
Annual Sum or Average | 0.481873E+11 | 0.464502E+10 | ||||||||
Minimum of Months | 0.143690E+10 | 5832.51 | 8.00 | 4.11 | 0.328432E+09 | 549.52 | 8.00 | 4.11 | ||
Maximum of Months | 0.767306E+10 | 14818.35 | 36.10 | 15.16 | 0.453833E+09 | 619.35 | 36.18 | 15.20 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.661754E+09 | 3742.72 | 23-JAN-16:10 | 18.17 | 6.14 | 0.219758E+09 | 347.83 | 25-JAN-14:20 | 14.67 | 4.64 |
February | 0.626375E+09 | 3987.14 | 17-FEB-16:30 | 13.50 | 6.66 | 0.199129E+09 | 347.84 | 23-FEB-14:20 | 9.00 | 4.54 |
March | 0.123347E+10 | 10443.10 | 12-MAR-16:12 | 18.00 | 5.71 | 0.247834E+09 | 347.85 | 16-MAR-09:20 | 11.67 | 3.37 |
April | 0.116799E+10 | 6956.35 | 08-APR-17:06 | 15.67 | 5.07 | 0.225653E+09 | 347.86 | 13-APR-13:00 | 15.00 | 9.82 |
May | 0.224660E+10 | 6172.32 | 31-MAY-16:00 | 28.00 | 14.86 | 0.269106E+09 | 347.85 | 17-MAY-09:20 | 28.00 | 14.86 |
June | 0.487563E+10 | 12809.27 | 25-JUN-16:31 | 32.70 | 13.89 | 0.276251E+09 | 347.86 | 27-JUN-09:20 | 25.53 | 11.25 |
July | 0.428288E+10 | 12622.50 | 01-JUL-17:41 | 28.17 | 10.55 | 0.256840E+09 | 347.85 | 11-JUL-09:30 | 25.50 | 13.66 |
August | 0.478825E+10 | 12472.47 | 13-AUG-17:42 | 22.83 | 10.50 | 0.288178E+09 | 347.86 | 21-AUG-09:20 | 25.67 | 14.10 |
September | 0.388046E+10 | 13797.55 | 10-SEP-17:11 | 30.13 | 12.08 | 0.254883E+09 | 347.88 | 05-SEP-09:09 | 30.13 | 12.08 |
October | 0.203532E+10 | 13143.23 | 09-OCT-16:11 | 21.67 | 8.64 | 0.246042E+09 | 347.85 | 12-OCT-09:30 | 3.00 | 0.96 |
November | 0.105402E+10 | 5425.95 | 07-NOV-15:40 | 21.33 | 7.24 | 0.230514E+09 | 347.84 | 09-NOV-14:20 | 19.33 | 8.45 |
December | 0.542171E+09 | 3042.82 | 04-DEC-15:30 | 18.00 | 5.80 | 0.208424E+09 | 347.83 | 18-DEC-14:00 | 5.00 | 0.54 |
Annual Sum or Average | 0.273949E+11 | 0.292261E+10 | ||||||||
Minimum of Months | 0.542171E+09 | 3042.82 | 13.50 | 5.07 | 0.199129E+09 | 347.83 | 3.00 | 0.54 | ||
Maximum of Months | 0.487563E+10 | 13797.55 | 32.70 | 14.86 | 0.288178E+09 | 347.88 | 30.13 | 14.86 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.685601E+09 | 1446.38 | 20-JAN-15:10 | 19.67 | 6.93 | 0.329973E+09 | 535.01 | 20-JAN-16:30 | 15.00 | 6.47 |
February | 0.596495E+09 | 1398.70 | 27-FEB-12:00 | 14.00 | 4.76 | 0.297722E+09 | 534.65 | 27-FEB-14:00 | 14.00 | 4.75 |
March | 0.123341E+10 | 3515.47 | 14-MAR-14:40 | 23.00 | 7.59 | 0.387725E+09 | 549.49 | 16-MAR-09:20 | 11.67 | 3.37 |
April | 0.134116E+10 | 3346.18 | 20-APR-13:30 | 21.50 | 8.83 | 0.355855E+09 | 549.51 | 13-APR-13:00 | 21.50 | 8.83 |
May | 0.306427E+10 | 5396.71 | 17-MAY-13:30 | 29.00 | 11.78 | 0.426600E+09 | 549.50 | 18-MAY-09:09 | 20.33 | 11.73 |
June | 0.582251E+10 | 10154.52 | 25-JUN-17:01 | 32.52 | 14.00 | 0.436246E+09 | 550.57 | 14-JUN-13:20 | 32.52 | 14.00 |
July | 0.568971E+10 | 9998.22 | 16-JUL-14:21 | 35.50 | 14.51 | 0.405682E+09 | 550.47 | 24-JUL-13:20 | 32.00 | 16.99 |
August | 0.524522E+10 | 7096.34 | 21-AUG-06:03 | 19.75 | 12.40 | 0.454366E+09 | 550.35 | 18-AUG-13:20 | 19.75 | 12.40 |
September | 0.373645E+10 | 7417.49 | 04-SEP-15:52 | 29.40 | 13.00 | 0.399560E+09 | 549.54 | 05-SEP-09:09 | 16.47 | 11.53 |
October | 0.154798E+10 | 3957.40 | 10-OCT-15:20 | 25.00 | 8.38 | 0.374429E+09 | 549.50 | 03-OCT-13:20 | 25.00 | 8.38 |
November | 0.919392E+09 | 2576.15 | 09-NOV-13:30 | 20.00 | 8.78 | 0.340888E+09 | 549.49 | 09-NOV-10:20 | 20.00 | 8.78 |
December | 0.509729E+09 | 1285.84 | 14-DEC-13:40 | 16.20 | 4.33 | 0.308834E+09 | 530.57 | 04-DEC-14:00 | 16.20 | 4.33 |
Annual Sum or Average | 0.303919E+11 | 0.451788E+10 | ||||||||
Minimum of Months | 0.509729E+09 | 1285.84 | 14.00 | 4.33 | 0.297722E+09 | 530.57 | 11.67 | 3.37 | ||
Maximum of Months | 0.582251E+10 | 10154.52 | 35.50 | 14.51 | 0.454366E+09 | 550.57 | 32.52 | 16.99 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.627978E+09 | 3766.21 | 26-JAN-13:02 | 9.00 | 2.97 | 0.168917E+09 | 356.45 | 13-JAN-11:09 | 9.00 | 2.97 |
February | 0.755315E+09 | 4892.32 | 27-FEB-09:05 | 9.17 | 2.67 | 0.155746E+09 | 356.45 | 14-FEB-11:09 | 9.17 | 2.67 |
March | 0.173415E+10 | 9613.22 | 12-MAR-09:43 | 14.83 | 5.50 | 0.194625E+09 | 356.46 | 27-MAR-10:09 | 0.33 | -0.4 |
April | 0.176714E+10 | 7608.22 | 21-APR-08:30 | 11.50 | 5.93 | 0.176088E+09 | 356.47 | 13-APR-10:09 | 11.50 | 5.93 |
May | 0.331455E+10 | 9446.15 | 28-MAY-09:02 | 12.33 | 8.71 | 0.203300E+09 | 356.48 | 31-MAY-10:09 | 25.17 | 13.22 |
June | 0.601468E+10 | 14229.57 | 11-JUN-08:12 | 18.13 | 10.80 | 0.205192E+09 | 356.47 | 20-JUN-14:09 | 23.67 | 16.48 |
July | 0.564390E+10 | 14814.12 | 23-JUL-08:41 | 25.00 | 15.32 | 0.191590E+09 | 356.46 | 18-JUL-14:09 | 25.00 | 15.32 |
August | 0.583908E+10 | 15284.59 | 06-AUG-09:01 | 25.33 | 15.45 | 0.213626E+09 | 356.49 | 30-AUG-10:09 | 25.17 | 12.29 |
September | 0.415678E+10 | 14439.87 | 04-SEP-09:11 | 24.97 | 13.41 | 0.188949E+09 | 356.48 | 18-SEP-10:09 | 25.18 | 11.04 |
October | 0.179810E+10 | 9864.48 | 01-OCT-09:23 | 13.50 | 7.83 | 0.181074E+09 | 356.46 | 10-OCT-14:09 | 25.00 | 8.67 |
November | 0.881802E+09 | 4744.40 | 07-NOV-09:00 | 14.00 | 4.09 | 0.171274E+09 | 356.46 | 13-NOV-11:09 | 4.00 | 2.18 |
December | 0.402832E+09 | 2085.57 | 14-DEC-11:05 | 13.50 | 3.41 | 0.156257E+09 | 356.45 | 15-DEC-11:09 | 8.50 | 1.88 |
Annual Sum or Average | 0.329363E+11 | 0.220664E+10 | ||||||||
Minimum of Months | 0.402832E+09 | 2085.57 | 9.00 | 2.67 | 0.155746E+09 | 356.45 | 0.33 | -0.4 | ||
Maximum of Months | 0.601468E+10 | 15284.59 | 25.33 | 15.45 | 0.213626E+09 | 356.49 | 25.18 | 16.48 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.442503E+10 | 14747.13 | 22-JAN-11:32 | 5.33 | 2.79 | 0.388982E+09 | 583.29 | 20-JAN-14:09 | 5.33 | 2.79 |
February | 0.399036E+10 | 14986.20 | 26-FEB-12:42 | 17.83 | 4.77 | 0.352198E+09 | 549.76 | 17-FEB-14:09 | 17.83 | 4.77 |
March | 0.440919E+10 | 14874.23 | 12-MAR-12:22 | 18.50 | 6.07 | 0.418593E+09 | 574.63 | 15-MAR-13:20 | 20.33 | 5.93 |
April | 0.285093E+10 | 9055.18 | 21-APR-13:05 | 15.83 | 6.37 | 0.372308E+09 | 550.31 | 21-APR-13:20 | 15.67 | 6.21 |
May | 0.418348E+10 | 7855.37 | 16-MAY-13:10 | 27.17 | 12.14 | 0.428635E+09 | 549.52 | 10-MAY-13:50 | 27.17 | 12.14 |
June | 0.664808E+10 | 14297.57 | 25-JUN-16:21 | 32.70 | 13.84 | 0.436012E+09 | 550.84 | 30-JUN-13:20 | 34.97 | 13.87 |
July | 0.674650E+10 | 14444.73 | 23-JUL-12:42 | 33.67 | 16.02 | 0.405761E+09 | 550.75 | 31-JUL-13:20 | 26.67 | 17.30 |
August | 0.800985E+10 | 15186.19 | 27-AUG-12:32 | 25.33 | 15.15 | 0.455167E+09 | 570.48 | 31-AUG-13:20 | 30.00 | 11.86 |
September | 0.758387E+10 | 16408.38 | 04-SEP-13:13 | 29.40 | 13.45 | 0.402936E+09 | 616.54 | 28-SEP-13:20 | 30.50 | 11.31 |
October | 0.584359E+10 | 15754.63 | 09-OCT-13:02 | 22.00 | 9.08 | 0.391549E+09 | 606.26 | 10-OCT-13:09 | 24.17 | 8.07 |
November | 0.482425E+10 | 15542.98 | 05-NOV-12:42 | 20.83 | 6.41 | 0.389675E+09 | 590.95 | 07-NOV-14:09 | 22.00 | 7.34 |
December | 0.343214E+10 | 14893.86 | 17-DEC-12:52 | 18.00 | 5.78 | 0.365907E+09 | 550.10 | 18-DEC-14:20 | 4.33 | 0.17 |
Annual Sum or Average | 0.629473E+11 | 0.480772E+10 | ||||||||
Minimum of Months | 0.285093E+10 | 7855.37 | 5.33 | 2.79 | 0.352198E+09 | 549.52 | 4.33 | 0.17 | ||
Maximum of Months | 0.800985E+10 | 16408.38 | 33.67 | 16.02 | 0.455167E+09 | 616.54 | 34.97 | 17.30 |
Report: ZoneCoolingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] | ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] | ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.913701E+09 | 4968.70 | 20-JAN-15:40 | 18.67 | 7.30 | 0.223501E+09 | 347.84 | 26-JAN-14:20 | 9.00 | 2.97 |
February | 0.929555E+09 | 5397.26 | 17-FEB-16:30 | 13.50 | 6.66 | 0.202769E+09 | 347.84 | 28-FEB-14:30 | 4.50 | 2.83 |
March | 0.180143E+10 | 9826.47 | 12-MAR-16:22 | 18.00 | 5.68 | 0.252576E+09 | 347.85 | 16-MAR-09:20 | 11.67 | 3.37 |
April | 0.167403E+10 | 10070.39 | 08-APR-17:06 | 15.67 | 5.07 | 0.229584E+09 | 347.86 | 13-APR-13:00 | 15.00 | 9.82 |
May | 0.312434E+10 | 9240.31 | 28-MAY-15:13 | 20.00 | 9.96 | 0.270703E+09 | 347.86 | 10-MAY-13:50 | 20.00 | 9.96 |
June | 0.563250E+10 | 16748.91 | 25-JUN-16:21 | 32.70 | 13.84 | 0.276245E+09 | 347.86 | 27-JUN-09:20 | 25.53 | 11.25 |
July | 0.495931E+10 | 15304.46 | 02-JUL-16:41 | 28.00 | 12.40 | 0.256938E+09 | 348.03 | 17-JUL-09:30 | 32.50 | 14.21 |
August | 0.516018E+10 | 14871.92 | 20-AUG-15:41 | 28.00 | 14.08 | 0.287962E+09 | 347.86 | 15-AUG-13:39 | 28.00 | 14.08 |
September | 0.386676E+10 | 16207.25 | 10-SEP-17:11 | 30.13 | 12.08 | 0.253604E+09 | 347.88 | 05-SEP-09:09 | 30.13 | 12.08 |
October | 0.210545E+10 | 13821.17 | 09-OCT-17:02 | 20.50 | 8.62 | 0.240560E+09 | 347.84 | 11-OCT-13:20 | 26.33 | 9.54 |
November | 0.114686E+10 | 7242.32 | 05-NOV-16:03 | 18.33 | 5.42 | 0.227151E+09 | 347.85 | 08-NOV-10:20 | 15.67 | 5.83 |
December | 0.610191E+09 | 3719.76 | 01-DEC-15:30 | 19.50 | 7.14 | 0.208293E+09 | 347.84 | 15-DEC-14:00 | 9.00 | 3.00 |
Annual Sum or Average | 0.319243E+11 | 0.292989E+10 | ||||||||
Minimum of Months | 0.610191E+09 | 3719.76 | 13.50 | 5.07 | 0.202769E+09 | 347.84 | 4.50 | 2.83 | ||
Maximum of Months | 0.563250E+10 | 16748.91 | 32.70 | 14.08 | 0.287962E+09 | 348.03 | 32.50 | 14.21 |
Report: ZoneHeatingSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.50 |
February | 0.00 | 0.00 | 01-FEB-00:10 | -5.3 |
March | 0.00 | 0.00 | 01-MAR-00:10 | -1.1 |
April | 0.00 | 0.00 | 01-APR-00:10 | 5.90 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 10.30 |
November | 0.00 | 0.00 | 01-NOV-00:10 | -5.7 |
December | 1881471.41 | 12543.14 | 26-DEC-07:03 | 6.83 |
Annual Sum or Average | 1881471.41 | |||
Minimum of Months | 0.00 | 0.00 | -5.7 | |
Maximum of Months | 1881471.41 | 12543.14 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.285147E+10 | 14340.32 | 05-JAN-06:13 | -17.0 |
February | 0.298219E+10 | 16092.72 | 13-FEB-06:12 | -10.7 |
March | 0.212549E+10 | 11294.89 | 20-MAR-05:13 | 0.00 |
April | 0.141774E+10 | 14379.84 | 03-APR-05:12 | -8.0 |
May | 0.476864E+09 | 5836.27 | 01-MAY-06:03 | 6.33 |
June | 0.139730E+09 | 4686.76 | 26-JUN-05:12 | 17.53 |
July | 0.112650E+09 | 4586.10 | 02-JUL-07:03 | 15.50 |
August | 0.154363E+09 | 3898.65 | 13-AUG-08:62 | 15.17 |
September | 0.364493E+09 | 4676.63 | 17-SEP-08:23 | 16.35 |
October | 0.178285E+10 | 13103.83 | 30-OCT-05:13 | -10.0 |
November | 0.220144E+10 | 14739.32 | 30-NOV-06:13 | -12.0 |
December | 0.433459E+10 | 17650.09 | 22-DEC-06:12 | -20.7 |
Annual Sum or Average | 0.189439E+11 | |||
Minimum of Months | 0.112650E+09 | 3898.65 | -20.7 | |
Maximum of Months | 0.433459E+10 | 17650.09 | 17.53 |
Report: ZoneHeatingSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.165912E+10 | 6834.25 | 16-JAN-13:53 | 1.00 |
February | 0.171277E+10 | 8494.49 | 06-FEB-07:11 | -9.3 |
March | 0.114250E+10 | 6244.82 | 20-MAR-06:01 | 0.00 |
April | 0.906985E+09 | 5087.73 | 17-APR-06:02 | -7.7 |
May | 0.197004E+09 | 3242.62 | 28-MAY-09:02 | 12.33 |
June | 28314649.63 | 4669.44 | 11-JUN-15:31 | 28.87 |
July | 37672182.82 | 3819.66 | 16-JUL-09:41 | 33.83 |
August | 25171032.39 | 4298.81 | 06-AUG-10:21 | 28.50 |
September | 80339776.84 | 5454.89 | 24-SEP-14:43 | 22.20 |
October | 0.735306E+09 | 6190.53 | 15-OCT-15:23 | 15.00 |
November | 0.138155E+10 | 6399.21 | 05-NOV-16:03 | 18.33 |
December | 0.209972E+10 | 8001.64 | 26-DEC-06:22 | 7.00 |
Annual Sum or Average | 0.100064E+11 | |||
Minimum of Months | 25171032.39 | 3242.62 | -9.3 | |
Maximum of Months | 0.209972E+10 | 8494.49 | 33.83 |
Report: ZoneHeatingSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.109072E+10 | 3652.05 | 31-JAN-08:04 | -2.8 |
February | 0.109294E+10 | 4697.24 | 02-FEB-08:05 | -7.5 |
March | 0.799332E+09 | 3888.19 | 24-MAR-07:06 | -0.2 |
April | 0.625966E+09 | 4213.02 | 24-APR-07:17 | 1.00 |
May | 0.110427E+09 | 2813.15 | 12-MAY-05:03 | 1.50 |
June | 21803064.48 | 2095.52 | 25-JUN-16:31 | 32.70 |
July | 28142283.73 | 2463.47 | 16-JUL-14:21 | 35.50 |
August | 24631321.19 | 2579.23 | 06-AUG-11:02 | 30.33 |
September | 42207046.91 | 4492.99 | 22-SEP-05:03 | -1.7 |
October | 0.463773E+09 | 5021.40 | 30-OCT-07:07 | -10.0 |
November | 0.829583E+09 | 4931.32 | 30-NOV-08:08 | -7.7 |
December | 0.145403E+10 | 4442.76 | 17-DEC-12:42 | 17.67 |
Annual Sum or Average | 0.658355E+10 | |||
Minimum of Months | 21803064.48 | 2095.52 | -10.0 | |
Maximum of Months | 0.145403E+10 | 5021.40 | 35.50 |
Report: ZoneHeatingSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 49908369.50 | 19009.59 | 02-JAN-06:01 | -2.8 |
February | 0.200469E+09 | 20481.66 | 06-FEB-06:01 | -10.0 |
March | 60768867.31 | 19737.05 | 20-MAR-05:01 | 0.00 |
April | 34710665.16 | 19224.87 | 03-APR-05:01 | -8.0 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 5.43 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 10185106.39 | 18184.86 | 31-OCT-06:01 | -9.0 |
November | 11687395.06 | 18138.32 | 01-NOV-06:01 | -2.8 |
December | 0.221047E+09 | 20852.14 | 26-DEC-06:11 | 7.00 |
Annual Sum or Average | 0.588777E+09 | |||
Minimum of Months | 0.00 | 0.00 | -10.0 | |
Maximum of Months | 0.221047E+09 | 20852.14 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.882537E+09 | 29627.61 | 02-JAN-05:11 | -2.3 |
February | 0.125920E+10 | 31599.78 | 06-FEB-05:01 | -10.0 |
March | 0.542507E+09 | 30479.14 | 20-MAR-04:01 | 0.83 |
April | 0.491050E+09 | 29741.19 | 17-APR-04:01 | -8.0 |
May | 15030863.55 | 25646.12 | 01-MAY-06:03 | 6.33 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 0.392190E+09 | 28707.92 | 30-OCT-05:01 | -10.0 |
November | 0.500560E+09 | 28501.35 | 30-NOV-06:01 | -12.0 |
December | 0.174512E+10 | 31446.56 | 26-DEC-06:11 | 7.00 |
Annual Sum or Average | 0.582819E+10 | |||
Minimum of Months | 0.00 | 0.00 | -12.0 | |
Maximum of Months | 0.174512E+10 | 31599.78 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.224234E+10 | 10292.16 | 06-JAN-05:01 | -7.8 |
February | 0.257992E+10 | 10845.80 | 12-FEB-05:42 | -19.2 |
March | 0.141889E+10 | 10895.14 | 19-MAR-06:42 | -15.2 |
April | 0.794316E+09 | 10194.31 | 24-APR-04:01 | -2.0 |
May | 48757493.50 | 9227.76 | 01-MAY-05:11 | 6.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 15269505.14 | 8187.95 | 22-SEP-05:03 | -1.7 |
October | 0.987345E+09 | 10177.05 | 30-OCT-04:32 | -10.0 |
November | 0.160053E+10 | 10356.07 | 30-NOV-05:11 | -12.7 |
December | 0.396125E+10 | 11132.69 | 24-DEC-03:32 | -20.3 |
Annual Sum or Average | 0.136486E+11 | |||
Minimum of Months | 0.00 | 0.00 | -20.3 | |
Maximum of Months | 0.396125E+10 | 11132.69 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.108875E+10 | 11452.95 | 06-JAN-05:01 | -7.8 |
February | 0.133095E+10 | 11942.09 | 12-FEB-05:42 | -19.2 |
March | 0.756036E+09 | 12008.19 | 19-MAR-06:42 | -15.2 |
April | 0.419763E+09 | 11409.42 | 24-APR-04:01 | -2.0 |
May | 16886592.58 | 10236.26 | 01-MAY-05:11 | 6.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 6932156.18 | 5499.17 | 22-SEP-05:03 | -1.7 |
October | 0.623124E+09 | 11241.54 | 30-OCT-04:32 | -10.0 |
November | 0.836359E+09 | 11529.54 | 30-NOV-05:11 | -12.7 |
December | 0.215915E+10 | 12330.50 | 24-DEC-03:32 | -20.3 |
Annual Sum or Average | 0.723795E+10 | |||
Minimum of Months | 0.00 | 0.00 | -20.3 | |
Maximum of Months | 0.215915E+10 | 12330.50 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.113140E+10 | 13862.88 | 06-JAN-05:01 | -7.8 |
February | 0.166870E+10 | 14480.21 | 06-FEB-04:12 | -10.0 |
March | 0.112801E+10 | 14613.54 | 19-MAR-06:42 | -15.2 |
April | 0.712130E+09 | 13785.13 | 24-APR-04:01 | -2.0 |
May | 52906732.10 | 12466.55 | 01-MAY-05:11 | 6.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 13316871.88 | 8450.68 | 22-SEP-06:03 | -1.4 |
October | 0.881173E+09 | 13656.22 | 30-OCT-04:32 | -10.0 |
November | 0.960861E+09 | 13925.74 | 30-NOV-05:11 | -12.7 |
December | 0.237216E+10 | 14886.39 | 24-DEC-04:52 | -19.0 |
Annual Sum or Average | 0.892065E+10 | |||
Minimum of Months | 0.00 | 0.00 | -19.0 | |
Maximum of Months | 0.237216E+10 | 14886.39 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.121134E+10 | 12210.10 | 06-JAN-05:01 | -7.8 |
February | 0.146479E+10 | 12666.41 | 12-FEB-05:42 | -19.2 |
March | 0.860025E+09 | 12853.40 | 19-MAR-06:42 | -15.2 |
April | 0.502654E+09 | 12058.56 | 24-APR-04:01 | -2.0 |
May | 34649712.90 | 10791.89 | 01-MAY-05:11 | 6.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 10777850.61 | 5948.31 | 22-SEP-05:03 | -1.7 |
October | 0.631053E+09 | 11927.13 | 30-OCT-04:32 | -10.0 |
November | 0.916119E+09 | 12305.30 | 30-NOV-05:11 | -12.7 |
December | 0.228983E+10 | 13222.94 | 24-DEC-03:32 | -20.3 |
Annual Sum or Average | 0.792125E+10 | |||
Minimum of Months | 0.00 | 0.00 | -20.3 | |
Maximum of Months | 0.228983E+10 | 13222.94 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.122457E+10 | 7425.35 | 02-JAN-05:02 | -2.2 |
February | 0.147547E+10 | 7862.29 | 13-FEB-05:01 | -11.0 |
March | 0.669904E+09 | 7394.07 | 20-MAR-04:01 | 0.83 |
April | 0.297829E+09 | 7310.77 | 17-APR-04:01 | -8.0 |
May | 7881468.21 | 6258.92 | 02-MAY-06:02 | 0.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 0.215488E+09 | 6995.58 | 31-OCT-05:01 | -8.2 |
November | 0.386717E+09 | 7067.74 | 01-NOV-05:01 | -3.0 |
December | 0.158314E+10 | 7695.45 | 23-DEC-05:01 | -21.4 |
Annual Sum or Average | 0.586101E+10 | |||
Minimum of Months | 0.00 | 0.00 | -21.4 | |
Maximum of Months | 0.158314E+10 | 7862.29 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.432514E+09 | 8538.84 | 06-JAN-05:01 | -7.8 |
February | 0.643460E+09 | 8980.31 | 06-FEB-05:01 | -10.0 |
March | 0.285145E+09 | 8509.79 | 20-MAR-04:01 | 0.83 |
April | 0.131998E+09 | 8288.42 | 04-APR-05:01 | -2.2 |
May | 1143182.51 | 3992.21 | 01-MAY-06:03 | 6.33 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 0.132052E+09 | 8157.53 | 31-OCT-05:01 | -8.2 |
November | 0.174929E+09 | 8232.47 | 01-NOV-05:01 | -3.0 |
December | 0.716117E+09 | 8988.34 | 23-DEC-05:01 | -21.4 |
Annual Sum or Average | 0.251736E+10 | |||
Minimum of Months | 0.00 | 0.00 | -21.4 | |
Maximum of Months | 0.716117E+09 | 8988.34 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.190238E+10 | 12448.43 | 05-JAN-07:10 | -17.0 |
February | 0.227553E+10 | 11996.15 | 06-FEB-07:50 | -8.3 |
March | 0.191699E+10 | 10946.88 | 29-MAR-06:10 | -7.7 |
April | 0.140994E+10 | 11269.86 | 17-APR-06:50 | -6.3 |
May | 0.462756E+09 | 9918.15 | 02-MAY-06:10 | 0.17 |
June | 8330852.42 | 6017.49 | 09-JUN-06:06 | 9.37 |
July | 1360953.05 | 2567.41 | 03-JUL-06:07 | 11.00 |
August | 524591.94 | 2672.21 | 23-AUG-06:08 | 12.50 |
September | 80890153.55 | 9450.99 | 22-SEP-06:10 | -1.4 |
October | 0.138436E+10 | 11420.66 | 30-OCT-06:10 | -10.0 |
November | 0.149597E+10 | 11738.92 | 30-NOV-07:10 | -11.3 |
December | 0.262228E+10 | 13123.26 | 21-DEC-08:00 | -20.0 |
Annual Sum or Average | 0.135613E+11 | |||
Minimum of Months | 524591.94 | 2567.41 | -20.0 | |
Maximum of Months | 0.262228E+10 | 13123.26 | 12.50 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.463198E+09 | 8375.37 | 06-JAN-05:01 | -7.8 |
February | 0.644895E+09 | 8945.82 | 06-FEB-05:01 | -10.0 |
March | 0.305756E+09 | 8435.20 | 20-MAR-04:01 | 0.83 |
April | 0.162054E+09 | 8427.27 | 17-APR-04:01 | -8.0 |
May | 4317430.28 | 5510.73 | 02-MAY-06:02 | 0.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 18.18 |
October | 0.135089E+09 | 8038.43 | 31-OCT-05:01 | -8.2 |
November | 0.163506E+09 | 8126.03 | 01-NOV-05:01 | -3.0 |
December | 0.752313E+09 | 8893.46 | 23-DEC-05:01 | -21.4 |
Annual Sum or Average | 0.263113E+10 | |||
Minimum of Months | 0.00 | 0.00 | -21.4 | |
Maximum of Months | 0.752313E+09 | 8945.82 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.890793E+09 | 8454.79 | 06-JAN-05:01 | -7.8 |
February | 0.112584E+10 | 8942.45 | 06-FEB-04:12 | -10.0 |
March | 0.442307E+09 | 8533.01 | 20-MAR-04:01 | 0.83 |
April | 0.265534E+09 | 8542.14 | 17-APR-04:01 | -8.0 |
May | 6467369.60 | 7015.65 | 02-MAY-06:02 | 0.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 346056.97 | 2307.05 | 22-SEP-06:03 | -1.4 |
October | 0.369415E+09 | 8392.84 | 30-OCT-04:01 | -10.0 |
November | 0.555984E+09 | 8378.39 | 01-NOV-04:01 | -3.0 |
December | 0.184736E+10 | 9013.37 | 24-DEC-06:41 | -19.7 |
Annual Sum or Average | 0.550404E+10 | |||
Minimum of Months | 0.00 | 0.00 | -19.7 | |
Maximum of Months | 0.184736E+10 | 9013.37 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.419143E+09 | 9171.79 | 06-JAN-05:01 | -7.8 |
February | 0.588140E+09 | 9408.35 | 06-FEB-05:01 | -10.0 |
March | 0.241008E+09 | 9167.87 | 20-MAR-04:01 | 0.83 |
April | 0.142024E+09 | 9162.98 | 17-APR-04:01 | -8.0 |
May | 1463940.70 | 4973.16 | 01-MAY-05:11 | 6.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 119229.26 | 794.86 | 22-SEP-06:03 | -1.4 |
October | 0.251944E+09 | 9014.97 | 30-OCT-04:01 | -10.0 |
November | 0.305165E+09 | 8991.12 | 30-NOV-05:02 | -12.8 |
December | 0.984936E+09 | 9703.26 | 21-DEC-05:01 | -18.2 |
Annual Sum or Average | 0.293394E+10 | |||
Minimum of Months | 0.00 | 0.00 | -18.2 | |
Maximum of Months | 0.984936E+09 | 9703.26 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.386364E+09 | 11756.65 | 06-JAN-05:01 | -7.8 |
February | 0.707524E+09 | 12268.82 | 06-FEB-05:01 | -10.0 |
March | 0.337208E+09 | 11975.33 | 20-MAR-04:01 | 0.83 |
April | 0.243569E+09 | 11992.49 | 17-APR-04:01 | -8.0 |
May | 7618965.72 | 8858.96 | 02-MAY-06:02 | 0.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 271000.09 | 1806.67 | 22-SEP-06:03 | -1.4 |
October | 0.343051E+09 | 11708.92 | 30-OCT-04:01 | -10.0 |
November | 0.308760E+09 | 11735.45 | 01-NOV-04:01 | -3.0 |
December | 0.961866E+09 | 12483.88 | 21-DEC-05:01 | -18.2 |
Annual Sum or Average | 0.329623E+10 | |||
Minimum of Months | 0.00 | 0.00 | -18.2 | |
Maximum of Months | 0.961866E+09 | 12483.88 | 22.27 |
Report: ZoneHeatingSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | |
January | 0.457870E+09 | 9041.73 | 06-JAN-05:01 | -7.8 |
February | 0.621366E+09 | 9382.26 | 06-FEB-05:01 | -10.0 |
March | 0.263441E+09 | 9120.67 | 20-MAR-04:01 | 0.83 |
April | 0.174005E+09 | 9211.33 | 17-APR-04:01 | -8.0 |
May | 5088071.47 | 5596.96 | 02-MAY-06:02 | 0.17 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 15.88 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 22.27 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 18.93 |
September | 404452.88 | 2224.23 | 22-SEP-06:03 | -1.4 |
October | 0.245246E+09 | 8954.02 | 30-OCT-04:01 | -10.0 |
November | 0.311837E+09 | 8930.76 | 01-NOV-04:01 | -3.0 |
December | 0.102762E+10 | 9685.13 | 21-DEC-05:01 | -18.2 |
Annual Sum or Average | 0.310688E+10 | |||
Minimum of Months | 0.00 | 0.00 | -18.2 | |
Maximum of Months | 0.102762E+10 | 9685.13 | 22.27 |
Report: ZoneElectricSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.463753E+10 | 4936.01 | 02-JAN-08:09 | 0.198672E+11 | 18185.19 | 02-JAN-08:09 |
February | 0.420695E+10 | 4936.01 | 01-FEB-08:09 | 0.179823E+11 | 18185.19 | 01-FEB-08:09 |
March | 0.500524E+10 | 4936.01 | 01-MAR-08:09 | 0.207117E+11 | 18185.19 | 01-MAR-08:09 |
April | 0.446441E+10 | 4936.01 | 03-APR-07:10 | 0.191625E+11 | 18185.19 | 03-APR-07:10 |
May | 0.482138E+10 | 4936.01 | 01-MAY-07:10 | 0.202894E+11 | 18185.19 | 01-MAY-07:10 |
June | 0.480039E+10 | 4936.01 | 01-JUN-07:10 | 0.199404E+11 | 18185.19 | 01-JUN-07:10 |
July | 0.448540E+10 | 4936.01 | 03-JUL-07:10 | 0.195094E+11 | 18185.19 | 03-JUL-07:10 |
August | 0.500520E+10 | 4936.01 | 01-AUG-07:10 | 0.207117E+11 | 18185.19 | 01-AUG-07:10 |
September | 0.446441E+10 | 4936.01 | 01-SEP-07:10 | 0.191582E+11 | 18185.19 | 01-SEP-07:10 |
October | 0.463757E+10 | 4936.01 | 02-OCT-07:10 | 0.198694E+11 | 18185.19 | 02-OCT-07:10 |
November | 0.458488E+10 | 4936.01 | 01-NOV-07:10 | 0.194582E+11 | 18185.19 | 01-NOV-07:10 |
December | 0.448544E+10 | 4936.01 | 01-DEC-08:09 | 0.195072E+11 | 18185.19 | 01-DEC-08:09 |
Annual Sum or Average | 0.555988E+11 | 0.236167E+12 | ||||
Minimum of Months | 0.420695E+10 | 4936.01 | 0.179823E+11 | 18185.19 | ||
Maximum of Months | 0.500524E+10 | 4936.01 | 0.207117E+11 | 18185.19 |
Report: ZoneElectricSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.463753E+10 | 4936.01 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.420695E+10 | 4936.01 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.500524E+10 | 4936.01 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.446441E+10 | 4936.01 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.482138E+10 | 4936.01 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.480039E+10 | 4936.01 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.448540E+10 | 4936.01 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.500520E+10 | 4936.01 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.446441E+10 | 4936.01 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.463757E+10 | 4936.01 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.458488E+10 | 4936.01 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.448544E+10 | 4936.01 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.555988E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.420695E+10 | 4936.01 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.500524E+10 | 4936.01 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.463753E+10 | 4936.01 | 02-JAN-08:09 | 0.971303E+10 | 6808.32 | 02-JAN-08:09 |
February | 0.420695E+10 | 4936.01 | 01-FEB-08:09 | 0.879311E+10 | 6808.32 | 01-FEB-08:09 |
March | 0.500524E+10 | 4936.01 | 01-MAR-08:09 | 0.101015E+11 | 6808.32 | 01-MAR-08:09 |
April | 0.446441E+10 | 4936.01 | 03-APR-07:10 | 0.937947E+10 | 6808.32 | 03-APR-07:10 |
May | 0.482138E+10 | 4936.01 | 01-MAY-07:10 | 0.990724E+10 | 6808.32 | 01-MAY-07:10 |
June | 0.480039E+10 | 4936.01 | 01-JUN-07:10 | 0.972788E+10 | 6808.32 | 01-JUN-07:10 |
July | 0.448540E+10 | 4936.01 | 03-JUL-07:10 | 0.955663E+10 | 6808.32 | 03-JUL-07:10 |
August | 0.500520E+10 | 4936.01 | 01-AUG-07:10 | 0.101015E+11 | 6808.32 | 01-AUG-07:10 |
September | 0.446441E+10 | 4936.01 | 01-SEP-07:10 | 0.937507E+10 | 6808.32 | 01-SEP-07:10 |
October | 0.463757E+10 | 4936.01 | 02-OCT-07:10 | 0.971523E+10 | 6808.32 | 02-OCT-07:10 |
November | 0.458488E+10 | 4936.01 | 01-NOV-07:10 | 0.950025E+10 | 6808.32 | 01-NOV-07:10 |
December | 0.448544E+10 | 4936.01 | 01-DEC-08:09 | 0.955443E+10 | 6808.32 | 01-DEC-08:09 |
Annual Sum or Average | 0.555988E+11 | 0.115425E+12 | ||||
Minimum of Months | 0.420695E+10 | 4936.01 | 0.879311E+10 | 6808.32 | ||
Maximum of Months | 0.500524E+10 | 4936.01 | 0.101015E+11 | 6808.32 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.632433E+09 | 1040.56 | 02-JAN-16:49 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.536537E+09 | 974.20 | 06-FEB-16:00 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.594511E+09 | 777.79 | 21-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.511746E+09 | 678.88 | 03-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.536936E+09 | 496.34 | 01-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.527790E+09 | 496.34 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.497008E+09 | 496.34 | 03-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.564921E+09 | 547.00 | 28-AUG-15:00 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.518404E+09 | 552.40 | 21-SEP-15:00 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.573174E+09 | 887.12 | 30-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.618415E+09 | 1040.56 | 06-NOV-16:49 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.619577E+09 | 1040.56 | 01-DEC-16:30 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.673145E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.497008E+09 | 496.34 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.632433E+09 | 1040.56 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.395215E+09 | 658.76 | 02-JAN-16:49 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.337499E+09 | 616.86 | 06-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.375865E+09 | 471.32 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.324744E+09 | 366.22 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.342216E+09 | 314.23 | 01-MAY-07:10 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.336681E+09 | 314.23 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.316982E+09 | 314.23 | 03-JUL-07:10 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.359535E+09 | 350.07 | 28-AUG-15:00 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.328456E+09 | 354.08 | 21-SEP-15:00 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.360182E+09 | 552.23 | 30-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.388642E+09 | 658.76 | 06-NOV-16:49 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.388271E+09 | 658.76 | 01-DEC-16:30 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.425429E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.316982E+09 | 314.23 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.395215E+09 | 658.76 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.600824E+09 | 1040.56 | 02-JAN-16:49 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.522739E+09 | 972.69 | 06-FEB-16:00 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.590523E+09 | 769.18 | 21-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.512944E+09 | 673.29 | 03-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.539455E+09 | 496.34 | 01-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.531316E+09 | 496.34 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.500275E+09 | 496.34 | 03-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.567221E+09 | 543.37 | 28-AUG-15:00 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.517323E+09 | 542.97 | 21-SEP-15:00 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.564566E+09 | 878.91 | 30-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.595172E+09 | 1040.56 | 06-NOV-16:49 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.596135E+09 | 1040.56 | 01-DEC-16:30 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.663849E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.500275E+09 | 496.34 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.600824E+09 | 1040.56 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.384905E+09 | 658.71 | 02-JAN-16:49 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.332041E+09 | 614.32 | 06-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.373250E+09 | 498.44 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.323044E+09 | 444.61 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.339556E+09 | 314.21 | 01-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.334084E+09 | 337.36 | 16-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.314742E+09 | 334.18 | 28-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.356078E+09 | 345.27 | 21-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.327008E+09 | 357.99 | 22-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.358866E+09 | 562.41 | 30-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.379519E+09 | 658.71 | 06-NOV-16:49 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.380113E+09 | 658.71 | 01-DEC-16:30 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.420321E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.314742E+09 | 314.21 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.384905E+09 | 658.71 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.630231E+09 | 1040.56 | 02-JAN-16:49 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.534669E+09 | 971.69 | 06-FEB-16:00 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.593606E+09 | 767.76 | 21-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.511305E+09 | 585.81 | 03-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.536580E+09 | 496.34 | 01-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.527501E+09 | 496.34 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.496642E+09 | 496.34 | 03-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.565059E+09 | 542.56 | 28-AUG-15:00 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.517762E+09 | 548.23 | 21-SEP-15:00 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.571603E+09 | 881.29 | 30-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.616578E+09 | 1040.56 | 06-NOV-16:49 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.617828E+09 | 1040.56 | 01-DEC-16:30 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.671937E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.496642E+09 | 496.34 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.630231E+09 | 1040.56 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.394283E+09 | 658.76 | 02-JAN-16:49 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.336740E+09 | 615.58 | 06-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.375234E+09 | 465.28 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.324507E+09 | 364.40 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.341987E+09 | 314.23 | 01-MAY-07:10 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.336478E+09 | 314.23 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.316808E+09 | 314.23 | 03-JUL-07:10 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.359231E+09 | 347.68 | 28-AUG-15:00 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.328100E+09 | 351.87 | 21-SEP-15:00 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.359599E+09 | 548.83 | 30-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.387566E+09 | 658.76 | 06-NOV-16:49 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.387212E+09 | 658.76 | 01-DEC-16:30 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.424775E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.316808E+09 | 314.23 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.394283E+09 | 658.76 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.600306E+09 | 1040.56 | 02-JAN-16:49 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.522022E+09 | 970.10 | 06-FEB-16:00 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.590089E+09 | 758.74 | 21-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.512460E+09 | 584.95 | 03-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.539041E+09 | 496.34 | 01-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.530893E+09 | 496.34 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.499906E+09 | 496.34 | 03-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.566731E+09 | 538.71 | 28-AUG-15:00 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.516886E+09 | 538.24 | 21-SEP-15:00 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.563871E+09 | 872.67 | 30-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.594080E+09 | 1040.56 | 06-NOV-16:49 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.593969E+09 | 1040.56 | 01-DEC-16:30 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.663025E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.499906E+09 | 496.34 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.600306E+09 | 1040.56 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.384236E+09 | 658.71 | 02-JAN-16:49 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.331468E+09 | 612.93 | 06-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.372847E+09 | 493.55 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.322816E+09 | 438.10 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.339369E+09 | 314.21 | 01-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.333945E+09 | 334.46 | 16-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.314566E+09 | 314.21 | 03-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.355875E+09 | 343.12 | 21-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.326701E+09 | 356.14 | 22-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.358190E+09 | 559.46 | 30-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.377694E+09 | 658.71 | 06-NOV-16:49 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.379572E+09 | 658.71 | 01-DEC-16:30 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.419728E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.314566E+09 | 314.21 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.384236E+09 | 658.71 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.632432E+09 | 1040.56 | 02-JAN-16:49 | 0.204758E+10 | 1435.25 | 02-JAN-08:09 |
February | 0.536536E+09 | 974.19 | 06-FEB-16:00 | 0.185366E+10 | 1435.25 | 01-FEB-08:09 |
March | 0.594510E+09 | 777.76 | 21-MAR-07:10 | 0.212947E+10 | 1435.25 | 01-MAR-08:09 |
April | 0.511746E+09 | 678.85 | 03-APR-07:10 | 0.197726E+10 | 1435.25 | 03-APR-07:10 |
May | 0.536936E+09 | 496.34 | 01-MAY-07:10 | 0.208852E+10 | 1435.25 | 01-MAY-07:10 |
June | 0.527790E+09 | 496.34 | 01-JUN-07:10 | 0.205071E+10 | 1435.25 | 01-JUN-07:10 |
July | 0.497007E+09 | 496.34 | 03-JUL-07:10 | 0.201461E+10 | 1435.25 | 03-JUL-07:10 |
August | 0.564921E+09 | 546.99 | 28-AUG-15:00 | 0.212947E+10 | 1435.25 | 01-AUG-07:10 |
September | 0.518404E+09 | 552.39 | 21-SEP-15:00 | 0.197634E+10 | 1435.25 | 01-SEP-07:10 |
October | 0.573173E+09 | 887.10 | 30-OCT-07:10 | 0.204804E+10 | 1435.25 | 02-OCT-07:10 |
November | 0.618413E+09 | 1040.56 | 06-NOV-16:49 | 0.200273E+10 | 1435.25 | 01-NOV-07:10 |
December | 0.619576E+09 | 1040.56 | 01-DEC-16:30 | 0.201415E+10 | 1435.25 | 01-DEC-08:09 |
Annual Sum or Average | 0.673144E+10 | 0.243325E+11 | ||||
Minimum of Months | 0.497007E+09 | 496.34 | 0.185366E+10 | 1435.25 | ||
Maximum of Months | 0.632432E+09 | 1040.56 | 0.212947E+10 | 1435.25 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.395215E+09 | 658.76 | 02-JAN-16:49 | 0.129621E+10 | 908.57 | 02-JAN-08:09 |
February | 0.337498E+09 | 616.85 | 06-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.375865E+09 | 471.30 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.324744E+09 | 366.21 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.342216E+09 | 314.23 | 01-MAY-07:10 | 0.132213E+10 | 908.57 | 01-MAY-07:10 |
June | 0.336681E+09 | 314.23 | 01-JUN-07:10 | 0.129819E+10 | 908.57 | 01-JUN-07:10 |
July | 0.316981E+09 | 314.23 | 03-JUL-07:10 | 0.127534E+10 | 908.57 | 03-JUL-07:10 |
August | 0.359535E+09 | 350.07 | 28-AUG-15:00 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.328456E+09 | 354.08 | 21-SEP-15:00 | 0.125111E+10 | 908.57 | 01-SEP-07:10 |
October | 0.360181E+09 | 552.22 | 30-OCT-07:10 | 0.129650E+10 | 908.57 | 02-OCT-07:10 |
November | 0.388641E+09 | 658.76 | 06-NOV-16:49 | 0.126781E+10 | 908.57 | 01-NOV-07:10 |
December | 0.388271E+09 | 658.76 | 01-DEC-16:30 | 0.127504E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.425428E+10 | 0.154036E+11 | ||||
Minimum of Months | 0.316981E+09 | 314.23 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.395215E+09 | 658.76 | 0.134804E+10 | 908.57 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.600823E+09 | 1040.56 | 02-JAN-16:49 | 0.204757E+10 | 1435.24 | 02-JAN-08:09 |
February | 0.522738E+09 | 972.68 | 06-FEB-16:00 | 0.185364E+10 | 1435.24 | 01-FEB-08:09 |
March | 0.590523E+09 | 769.15 | 21-MAR-07:10 | 0.212945E+10 | 1435.24 | 01-MAR-08:09 |
April | 0.512944E+09 | 673.25 | 03-APR-07:10 | 0.197725E+10 | 1435.24 | 03-APR-07:10 |
May | 0.539455E+09 | 496.34 | 01-MAY-07:10 | 0.208851E+10 | 1435.24 | 01-MAY-07:10 |
June | 0.531316E+09 | 496.34 | 01-JUN-07:10 | 0.205070E+10 | 1435.24 | 01-JUN-07:10 |
July | 0.500274E+09 | 496.34 | 03-JUL-07:10 | 0.201460E+10 | 1435.24 | 03-JUL-07:10 |
August | 0.567221E+09 | 543.36 | 28-AUG-15:00 | 0.212945E+10 | 1435.24 | 01-AUG-07:10 |
September | 0.517322E+09 | 542.95 | 21-SEP-15:00 | 0.197632E+10 | 1435.24 | 01-SEP-07:10 |
October | 0.564566E+09 | 878.90 | 30-OCT-07:10 | 0.204803E+10 | 1435.24 | 02-OCT-07:10 |
November | 0.595171E+09 | 1040.56 | 06-NOV-16:49 | 0.200271E+10 | 1435.24 | 01-NOV-07:10 |
December | 0.596135E+09 | 1040.56 | 01-DEC-16:30 | 0.201413E+10 | 1435.24 | 01-DEC-08:09 |
Annual Sum or Average | 0.663849E+10 | 0.243324E+11 | ||||
Minimum of Months | 0.500274E+09 | 496.34 | 0.185364E+10 | 1435.24 | ||
Maximum of Months | 0.600823E+09 | 1040.56 | 0.212945E+10 | 1435.24 |
Report: ZoneElectricSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE LIGHTS ELECTRICITY ENERGY [J] | ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] | ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP} | |
January | 0.384904E+09 | 658.71 | 02-JAN-16:49 | 0.129620E+10 | 908.57 | 02-JAN-08:09 |
February | 0.332041E+09 | 614.32 | 06-FEB-16:00 | 0.117344E+10 | 908.57 | 01-FEB-08:09 |
March | 0.373249E+09 | 498.42 | 21-MAR-07:10 | 0.134804E+10 | 908.57 | 01-MAR-08:09 |
April | 0.323044E+09 | 444.59 | 03-APR-07:10 | 0.125169E+10 | 908.57 | 03-APR-07:10 |
May | 0.339556E+09 | 314.21 | 01-MAY-07:10 | 0.132212E+10 | 908.57 | 01-MAY-07:10 |
June | 0.334084E+09 | 337.35 | 16-JUN-07:10 | 0.129818E+10 | 908.57 | 01-JUN-07:10 |
July | 0.314742E+09 | 334.17 | 28-JUL-07:10 | 0.127533E+10 | 908.57 | 03-JUL-07:10 |
August | 0.356078E+09 | 345.27 | 21-AUG-07:10 | 0.134804E+10 | 908.57 | 01-AUG-07:10 |
September | 0.327008E+09 | 357.99 | 22-SEP-07:10 | 0.125110E+10 | 908.57 | 01-SEP-07:10 |
October | 0.358865E+09 | 562.40 | 30-OCT-07:10 | 0.129649E+10 | 908.57 | 02-OCT-07:10 |
November | 0.379519E+09 | 658.71 | 06-NOV-16:49 | 0.126780E+10 | 908.57 | 01-NOV-07:10 |
December | 0.380113E+09 | 658.71 | 01-DEC-16:30 | 0.127503E+10 | 908.57 | 01-DEC-08:09 |
Annual Sum or Average | 0.420320E+10 | 0.154035E+11 | ||||
Minimum of Months | 0.314742E+09 | 314.21 | 0.117344E+10 | 908.57 | ||
Maximum of Months | 0.384904E+09 | 658.71 | 0.134804E+10 | 908.57 |
Report: SpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.463753E+10 | 0.198672E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.420695E+10 | 0.179823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.500524E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.446441E+10 | 0.191625E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.482138E+10 | 0.202894E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.480039E+10 | 0.199404E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.448540E+10 | 0.195094E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.500520E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.446441E+10 | 0.191582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.463757E+10 | 0.198694E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.458488E+10 | 0.194582E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.448544E+10 | 0.195072E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.555988E+11 | 0.236167E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.420695E+10 | 0.179823E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.500524E+10 | 0.207117E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.463753E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.420695E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.500524E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.446441E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.482138E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.480039E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.448540E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.500520E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.446441E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.463757E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.458488E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.448544E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.555988E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.420695E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.500524E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 0.471610E+10 | 0.463753E+10 | 0.971303E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.427861E+10 | 0.420695E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.511242E+10 | 0.500524E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.453654E+10 | 0.446441E+10 | 0.937947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.491426E+10 | 0.482138E+10 | 0.990724E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.490054E+10 | 0.480039E+10 | 0.972788E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.455026E+10 | 0.448540E+10 | 0.955663E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.511242E+10 | 0.500520E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.453654E+10 | 0.446441E+10 | 0.937507E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.471610E+10 | 0.463757E+10 | 0.971523E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.467005E+10 | 0.458488E+10 | 0.950025E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.455026E+10 | 0.448544E+10 | 0.955443E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.565941E+11 | 0.555988E+11 | 0.115425E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.427861E+10 | 0.420695E+10 | 0.879311E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.511242E+10 | 0.500524E+10 | 0.101015E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.632433E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.528332E+09 |
February | 0.901968E+09 | 0.536537E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.850309E+09 |
March | 0.107774E+10 | 0.594511E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.919173E+09 |
April | 0.956342E+09 | 0.511746E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.971836E+09 |
May | 0.103597E+10 | 0.536936E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2205533.33 | 0.527524E+09 |
June | 0.103308E+10 | 0.527790E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 46090069.94 | 0.232598E+09 |
July | 0.959235E+09 | 0.497008E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57967862.07 | 0.231349E+09 |
August | 0.107774E+10 | 0.564921E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31528595.53 | 0.227191E+09 |
September | 0.956342E+09 | 0.518404E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16909205.91 | 0.333166E+09 |
October | 0.994195E+09 | 0.573174E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 309098.69 | 0.705801E+09 |
November | 0.984487E+09 | 0.618415E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.606954E+09 |
December | 0.959235E+09 | 0.619577E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39.18 | 0.114113E+10 |
Annual Sum or Average | 0.119305E+11 | 0.673145E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.155010E+09 | 0.727536E+10 |
Minimum of Months | 0.901968E+09 | 0.497008E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.227191E+09 |
Maximum of Months | 0.107774E+10 | 0.632433E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57967862.07 | 0.114113E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.395215E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.362334E+09 |
February | 0.571020E+09 | 0.337499E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.581462E+09 |
March | 0.682301E+09 | 0.375865E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.631377E+09 |
April | 0.605444E+09 | 0.324744E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.664932E+09 |
May | 0.655854E+09 | 0.342216E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1469656.18 | 0.359875E+09 |
June | 0.654023E+09 | 0.336681E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30167264.81 | 0.158291E+09 |
July | 0.607275E+09 | 0.316982E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37749487.37 | 0.160430E+09 |
August | 0.682301E+09 | 0.359535E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20413847.41 | 0.156817E+09 |
September | 0.605444E+09 | 0.328456E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10445090.89 | 0.232020E+09 |
October | 0.629407E+09 | 0.360182E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 206061.82 | 0.487309E+09 |
November | 0.623262E+09 | 0.388642E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.413632E+09 |
December | 0.607275E+09 | 0.388271E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.771940E+09 |
Annual Sum or Average | 0.755301E+10 | 0.425429E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100451E+09 | 0.498042E+10 |
Minimum of Months | 0.571020E+09 | 0.316982E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.156817E+09 |
Maximum of Months | 0.682301E+09 | 0.395215E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37749487.37 | 0.771940E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.600824E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.580926E+09 |
February | 0.901968E+09 | 0.522739E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.905542E+09 |
March | 0.107774E+10 | 0.590523E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.968551E+09 |
April | 0.956342E+09 | 0.512944E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.996865E+09 |
May | 0.103597E+10 | 0.539455E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2204248.57 | 0.536018E+09 |
June | 0.103308E+10 | 0.531316E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 45717185.34 | 0.231881E+09 |
July | 0.959235E+09 | 0.500275E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57362123.80 | 0.232537E+09 |
August | 0.107774E+10 | 0.567221E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30559021.99 | 0.236323E+09 |
September | 0.956342E+09 | 0.517323E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 15092694.95 | 0.354167E+09 |
October | 0.994195E+09 | 0.564566E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 263112.54 | 0.751687E+09 |
November | 0.984487E+09 | 0.595172E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.655102E+09 |
December | 0.959235E+09 | 0.596135E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121337E+10 |
Annual Sum or Average | 0.119305E+11 | 0.663849E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.151198E+09 | 0.766297E+10 |
Minimum of Months | 0.901968E+09 | 0.500275E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.231881E+09 |
Maximum of Months | 0.107774E+10 | 0.600824E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 57362123.80 | 0.121337E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.384905E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.363639E+09 |
February | 0.570983E+09 | 0.332041E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.582873E+09 |
March | 0.682256E+09 | 0.373250E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.631712E+09 |
April | 0.605404E+09 | 0.323044E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.661075E+09 |
May | 0.655811E+09 | 0.339556E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1469137.85 | 0.364297E+09 |
June | 0.653980E+09 | 0.334084E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 30054419.51 | 0.162048E+09 |
July | 0.607235E+09 | 0.314742E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37512462.78 | 0.159875E+09 |
August | 0.682256E+09 | 0.356078E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20648961.71 | 0.160704E+09 |
September | 0.605404E+09 | 0.327008E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 10369081.76 | 0.234108E+09 |
October | 0.629366E+09 | 0.358866E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 206085.60 | 0.484729E+09 |
November | 0.623221E+09 | 0.379519E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.416097E+09 |
December | 0.607235E+09 | 0.380113E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.774485E+09 |
Annual Sum or Average | 0.755252E+10 | 0.420321E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.100260E+09 | 0.499564E+10 |
Minimum of Months | 0.570983E+09 | 0.314742E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.159875E+09 |
Maximum of Months | 0.682256E+09 | 0.384905E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 37512462.78 | 0.774485E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.630231E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.295803E+09 |
February | 0.901968E+09 | 0.534669E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.466033E+09 |
March | 0.107774E+10 | 0.593606E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 111.67 | 0.503327E+09 |
April | 0.956342E+09 | 0.511305E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.540649E+09 |
May | 0.103597E+10 | 0.536580E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1216827.72 | 0.281118E+09 |
June | 0.103308E+10 | 0.527501E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26595524.28 | 0.121374E+09 |
July | 0.959235E+09 | 0.496642E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34478830.68 | 0.120423E+09 |
August | 0.107774E+10 | 0.565059E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17933470.89 | 0.122256E+09 |
September | 0.956342E+09 | 0.517762E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 9802048.25 | 0.188626E+09 |
October | 0.994195E+09 | 0.571603E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 170752.24 | 0.409934E+09 |
November | 0.984487E+09 | 0.616578E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.348484E+09 |
December | 0.959235E+09 | 0.617828E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1247.26 | 0.641491E+09 |
Annual Sum or Average | 0.119305E+11 | 0.671937E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 90198812.98 | 0.403952E+10 |
Minimum of Months | 0.901968E+09 | 0.496642E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.120423E+09 |
Maximum of Months | 0.107774E+10 | 0.630231E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 34478830.68 | 0.641491E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629407E+09 | 0.394283E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.206273E+09 |
February | 0.571020E+09 | 0.336740E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.324711E+09 |
March | 0.682301E+09 | 0.375234E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 2.44 | 0.353223E+09 |
April | 0.605444E+09 | 0.324507E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.379595E+09 |
May | 0.655854E+09 | 0.341987E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 802650.10 | 0.197843E+09 |
June | 0.654023E+09 | 0.336478E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16540242.29 | 86905516.85 |
July | 0.607275E+09 | 0.316808E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20823348.80 | 88174352.18 |
August | 0.682301E+09 | 0.359231E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11033101.40 | 89127488.95 |
September | 0.605444E+09 | 0.328100E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5690743.79 | 0.135773E+09 |
October | 0.629407E+09 | 0.359599E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 113830.06 | 0.287271E+09 |
November | 0.623262E+09 | 0.387566E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.241068E+09 |
December | 0.607275E+09 | 0.387212E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.440543E+09 |
Annual Sum or Average | 0.755301E+10 | 0.424775E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 55003918.87 | 0.283051E+10 |
Minimum of Months | 0.571020E+09 | 0.316808E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 86905516.85 |
Maximum of Months | 0.682301E+09 | 0.394283E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20823348.80 | 0.440543E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.600306E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.452910E+10 |
February | 0.901968E+09 | 0.522022E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.458268E+10 |
March | 0.107774E+10 | 0.590089E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.404306E+10 |
April | 0.956342E+09 | 0.512460E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.315910E+10 |
May | 0.103597E+10 | 0.539041E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 54191096.47 | 0.195993E+10 |
June | 0.103308E+10 | 0.530893E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.746356E+09 | 0.518681E+09 |
July | 0.959235E+09 | 0.499906E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.609064E+09 | 0.495174E+09 |
August | 0.107774E+10 | 0.566731E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.653010E+09 | 0.696399E+09 |
September | 0.956342E+09 | 0.516886E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.278956E+09 | 0.109208E+10 |
October | 0.994195E+09 | 0.563871E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 4257877.99 | 0.359695E+10 |
November | 0.984487E+09 | 0.594080E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.434415E+10 |
December | 0.959235E+09 | 0.593969E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.525659E+10 |
Annual Sum or Average | 0.119305E+11 | 0.663025E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.234584E+10 | 0.342739E+11 |
Minimum of Months | 0.901968E+09 | 0.499906E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.495174E+09 |
Maximum of Months | 0.107774E+10 | 0.600306E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.746356E+09 | 0.525659E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.384236E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.207119E+09 |
February | 0.570983E+09 | 0.331468E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.325318E+09 |
March | 0.682256E+09 | 0.372847E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 3.11 | 0.352324E+09 |
April | 0.605404E+09 | 0.322816E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.376930E+09 |
May | 0.655811E+09 | 0.339369E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 800132.07 | 0.199505E+09 |
June | 0.653980E+09 | 0.333945E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16529110.62 | 89614818.52 |
July | 0.607235E+09 | 0.314566E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20716386.09 | 87437491.13 |
August | 0.682256E+09 | 0.355875E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 11257628.71 | 91349742.52 |
September | 0.605404E+09 | 0.326701E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 5632170.36 | 0.137292E+09 |
October | 0.629366E+09 | 0.358190E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 113841.54 | 0.287095E+09 |
November | 0.623221E+09 | 0.377694E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.242453E+09 |
December | 0.607235E+09 | 0.379572E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.441439E+09 |
Annual Sum or Average | 0.755252E+10 | 0.419728E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 55049272.50 | 0.283788E+10 |
Minimum of Months | 0.570983E+09 | 0.314566E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 87437491.13 |
Maximum of Months | 0.682256E+09 | 0.384236E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 20716386.09 | 0.441439E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.632432E+09 | 0.204758E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.469408E+09 |
February | 0.901968E+09 | 0.536536E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.740439E+09 |
March | 0.107774E+10 | 0.594510E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.803958E+09 |
April | 0.956342E+09 | 0.511746E+09 | 0.197726E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.863037E+09 |
May | 0.103597E+10 | 0.536936E+09 | 0.208852E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1859491.18 | 0.459573E+09 |
June | 0.103308E+10 | 0.527790E+09 | 0.205071E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 39088029.65 | 0.199998E+09 |
July | 0.959235E+09 | 0.497007E+09 | 0.201461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49688617.74 | 0.198870E+09 |
August | 0.107774E+10 | 0.564921E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 26818913.70 | 0.196760E+09 |
September | 0.956342E+09 | 0.518404E+09 | 0.197634E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 14469410.43 | 0.293514E+09 |
October | 0.994195E+09 | 0.573173E+09 | 0.204804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 262265.99 | 0.628643E+09 |
November | 0.984487E+09 | 0.618413E+09 | 0.200273E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.538047E+09 |
December | 0.959235E+09 | 0.619576E+09 | 0.201415E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.992817E+09 |
Annual Sum or Average | 0.119305E+11 | 0.673144E+10 | 0.243325E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.132187E+09 | 0.638506E+10 |
Minimum of Months | 0.901968E+09 | 0.497007E+09 | 0.185366E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.196760E+09 |
Maximum of Months | 0.107774E+10 | 0.632432E+09 | 0.212947E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 49688617.74 | 0.992817E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.465148E+09 | 0.395215E+09 | 0.129621E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.322384E+09 |
February | 0.421807E+09 | 0.337498E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.506756E+09 |
March | 0.502994E+09 | 0.375865E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.550985E+09 |
April | 0.447140E+09 | 0.324744E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.589212E+09 |
May | 0.484071E+09 | 0.342216E+09 | 0.132213E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1161198.58 | 0.313133E+09 |
June | 0.482240E+09 | 0.336681E+09 | 0.129819E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 24973332.08 | 0.136182E+09 |
July | 0.448971E+09 | 0.316981E+09 | 0.127534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31525671.94 | 0.137773E+09 |
August | 0.502994E+09 | 0.359535E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 16744565.48 | 0.135733E+09 |
September | 0.447140E+09 | 0.328456E+09 | 0.125111E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8591926.30 | 0.203271E+09 |
October | 0.465148E+09 | 0.360181E+09 | 0.129650E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 152632.13 | 0.431744E+09 |
November | 0.460569E+09 | 0.388641E+09 | 0.126781E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.366706E+09 |
December | 0.448971E+09 | 0.388271E+09 | 0.127504E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.673868E+09 |
Annual Sum or Average | 0.557719E+10 | 0.425428E+10 | 0.154036E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 83149326.52 | 0.436775E+10 |
Minimum of Months | 0.421807E+09 | 0.316981E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.135733E+09 |
Maximum of Months | 0.502994E+09 | 0.395215E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31525671.94 | 0.673868E+09 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.994195E+09 | 0.600823E+09 | 0.204757E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.514108E+09 |
February | 0.901968E+09 | 0.522738E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.788870E+09 |
March | 0.107774E+10 | 0.590523E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.844726E+09 |
April | 0.956342E+09 | 0.512944E+09 | 0.197725E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.883875E+09 |
May | 0.103597E+10 | 0.539455E+09 | 0.208851E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1857011.05 | 0.466306E+09 |
June | 0.103308E+10 | 0.531316E+09 | 0.205070E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 38510970.47 | 0.199703E+09 |
July | 0.959235E+09 | 0.500274E+09 | 0.201460E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48802082.23 | 0.200307E+09 |
August | 0.107774E+10 | 0.567221E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25670689.84 | 0.204518E+09 |
September | 0.956342E+09 | 0.517322E+09 | 0.197632E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 12692737.73 | 0.310072E+09 |
October | 0.994195E+09 | 0.564566E+09 | 0.204803E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 178627.96 | 0.664334E+09 |
November | 0.984487E+09 | 0.595171E+09 | 0.200271E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.576898E+09 |
December | 0.959235E+09 | 0.596135E+09 | 0.201413E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.106035E+10 |
Annual Sum or Average | 0.119305E+11 | 0.663849E+10 | 0.243324E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.127712E+09 | 0.671407E+10 |
Minimum of Months | 0.901968E+09 | 0.500274E+09 | 0.185364E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.199703E+09 |
Maximum of Months | 0.107774E+10 | 0.600823E+09 | 0.212945E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 48802082.23 | 0.106035E+10 |
Report: SpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [J] | ZONE LIGHTS TOTAL HEATING ENERGY [J] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.629366E+09 | 0.384904E+09 | 0.129620E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.322766E+09 |
February | 0.570983E+09 | 0.332041E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.507345E+09 |
March | 0.682256E+09 | 0.373249E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.551159E+09 |
April | 0.605404E+09 | 0.323044E+09 | 0.125169E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.586229E+09 |
May | 0.655811E+09 | 0.339556E+09 | 0.132212E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 1237422.04 | 0.316697E+09 |
June | 0.653980E+09 | 0.334084E+09 | 0.129818E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 25289382.84 | 0.139573E+09 |
July | 0.607235E+09 | 0.314742E+09 | 0.127533E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31646689.31 | 0.137707E+09 |
August | 0.682256E+09 | 0.356078E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 17361536.58 | 0.139061E+09 |
September | 0.605404E+09 | 0.327008E+09 | 0.125110E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 8684466.81 | 0.205485E+09 |
October | 0.629366E+09 | 0.358865E+09 | 0.129649E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 174850.44 | 0.430074E+09 |
November | 0.623221E+09 | 0.379519E+09 | 0.126780E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.367929E+09 |
December | 0.607235E+09 | 0.380113E+09 | 0.127503E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.674610E+09 |
Annual Sum or Average | 0.755252E+10 | 0.420320E+10 | 0.154035E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 84394348.02 | 0.437864E+10 |
Minimum of Months | 0.570983E+09 | 0.314742E+09 | 0.117344E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.137707E+09 |
Maximum of Months | 0.682256E+09 | 0.384904E+09 | 0.134804E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 31646689.31 | 0.674610E+09 |
Report: SpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.668912E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.104546E+10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.113974E+10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.121515E+10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1733309.10 | 0.624944E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45182711.25 | 0.268287E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60076543.79 | 0.266584E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 28842518.27 | 0.269843E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14884551.99 | 0.413331E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126479.70 | 0.896508E+09 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.765682E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.140886E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150846E+09 | 0.898329E+10 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.266584E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60076543.79 | 0.140886E+10 |
Report: SpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.820041E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.129287E+10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.141212E+10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150305E+10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2257833.64 | 0.789885E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57710881.17 | 0.344720E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76683351.59 | 0.342861E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37373834.94 | 0.342929E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19958410.01 | 0.517954E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188773.96 | 0.110464E+10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.938275E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.172334E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.194173E+09 | 0.111327E+11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.342861E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 76683351.59 | 0.172334E+10 |
Report: SpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.816216E+09 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.130235E+10 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.142301E+10 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.150477E+10 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1424703.21 | 0.820405E+09 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49165266.08 | 0.348816E+09 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61010502.82 | 0.349683E+09 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 31300463.85 | 0.348088E+09 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14074320.67 | 0.514515E+09 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50024.79 | 0.109730E+10 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.934135E+09 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.171981E+10 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.157025E+09 | 0.111791E+11 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.348088E+09 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61010502.82 | 0.171981E+10 |
Report: PeakSpaceGainsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4936.01 | 02-JAN-08:09 | 18185.19 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4936.01 | 01-FEB-08:09 | 18185.19 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4936.01 | 01-MAR-08:09 | 18185.19 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4936.01 | 03-APR-07:10 | 18185.19 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4936.01 | 01-MAY-07:10 | 18185.19 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4936.01 | 01-JUN-07:10 | 18185.19 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4936.01 | 03-JUL-07:10 | 18185.19 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4936.01 | 01-AUG-07:10 | 18185.19 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4936.01 | 01-SEP-07:10 | 18185.19 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4936.01 | 02-OCT-07:10 | 18185.19 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4936.01 | 01-NOV-07:10 | 18185.19 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4936.01 | 01-DEC-08:09 | 18185.19 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4936.01 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4936.01 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4936.01 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4936.01 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4936.01 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4936.01 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4936.01 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4936.01 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4936.01 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4936.01 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4936.01 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4936.01 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4936.01 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4936.01 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 6198.29 | 02-JAN-10:09 | 4936.01 | 02-JAN-08:09 | 6808.32 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 6198.29 | 01-FEB-10:09 | 4936.01 | 01-FEB-08:09 | 6808.32 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 6198.29 | 01-MAR-10:09 | 4936.01 | 01-MAR-08:09 | 6808.32 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 6198.29 | 03-APR-09:09 | 4936.01 | 03-APR-07:10 | 6808.32 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 6198.29 | 01-MAY-09:09 | 4936.01 | 01-MAY-07:10 | 6808.32 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 6198.29 | 01-JUN-09:09 | 4936.01 | 01-JUN-07:10 | 6808.32 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 6198.29 | 03-JUL-09:09 | 4936.01 | 03-JUL-07:10 | 6808.32 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 6198.29 | 01-AUG-09:09 | 4936.01 | 01-AUG-07:10 | 6808.32 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 6198.29 | 01-SEP-09:09 | 4936.01 | 01-SEP-07:10 | 6808.32 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 6198.29 | 02-OCT-09:09 | 4936.01 | 02-OCT-07:10 | 6808.32 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 6198.29 | 01-NOV-09:09 | 4936.01 | 01-NOV-07:10 | 6808.32 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6198.29 | 01-DEC-10:09 | 4936.01 | 01-DEC-08:09 | 6808.32 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||
Minimum of Months | 6198.29 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||
Maximum of Months | 6198.29 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1040.56 | 02-JAN-16:49 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1007.83 | 12-JAN-22:03 |
February | 1306.65 | 01-FEB-10:09 | 974.20 | 06-FEB-16:00 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1293.06 | 05-FEB-23:00 |
March | 1306.65 | 01-MAR-10:09 | 777.79 | 21-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 2881.73 | 19-MAR-07:00 |
April | 1306.65 | 03-APR-09:09 | 678.88 | 03-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1857.43 | 15-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 496.34 | 01-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.30 | 17-MAY-14:50 | 1024.64 | 03-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 496.34 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 298.24 | 25-JUN-17:54 | 657.20 | 08-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 496.34 | 03-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 497.27 | 16-JUL-11:54 | 649.31 | 03-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 547.00 | 28-AUG-15:00 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 171.41 | 02-AUG-16:00 | 819.31 | 27-AUG-18:00 |
September | 1306.65 | 01-SEP-09:09 | 552.40 | 21-SEP-15:00 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 190.22 | 10-SEP-15:00 | 701.81 | 21-SEP-23:00 |
October | 1306.65 | 02-OCT-09:09 | 887.12 | 30-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 25.07 | 11-OCT-14:00 | 1487.30 | 29-OCT-09:00 |
November | 1306.65 | 01-NOV-09:09 | 1040.56 | 06-NOV-16:49 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1599.35 | 01-NOV-04:07 |
December | 1306.65 | 01-DEC-10:09 | 1040.56 | 01-DEC-16:30 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.07 | 02-DEC-15:00 | 2395.37 | 21-DEC-23:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 649.31 | |||||
Maximum of Months | 1306.65 | 1040.56 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 497.27 | 2881.73 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 658.76 | 02-JAN-16:49 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 672.08 | 12-JAN-22:03 |
February | 827.22 | 01-FEB-10:09 | 616.86 | 06-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 862.03 | 05-FEB-23:00 |
March | 827.22 | 01-MAR-10:09 | 471.32 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1921.16 | 19-MAR-07:00 |
April | 827.22 | 03-APR-09:09 | 366.22 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1238.28 | 15-APR-05:00 |
May | 827.22 | 01-MAY-09:09 | 314.23 | 01-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.20 | 17-MAY-14:50 | 684.28 | 03-MAY-03:00 |
June | 827.22 | 01-JUN-09:09 | 314.23 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 212.98 | 25-JUN-17:54 | 438.10 | 08-JUN-23:00 |
July | 827.22 | 03-JUL-09:09 | 314.23 | 03-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 334.54 | 16-JUL-11:54 | 473.07 | 02-JUL-09:00 |
August | 827.22 | 01-AUG-09:09 | 350.07 | 28-AUG-15:00 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.27 | 02-AUG-16:00 | 560.67 | 27-AUG-18:00 |
September | 827.22 | 01-SEP-09:09 | 354.08 | 21-SEP-15:00 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 128.17 | 10-SEP-14:45 | 468.44 | 21-SEP-23:00 |
October | 827.22 | 02-OCT-09:09 | 552.23 | 30-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.71 | 11-OCT-14:00 | 996.22 | 29-OCT-09:00 |
November | 827.22 | 01-NOV-09:09 | 658.76 | 06-NOV-16:49 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1066.23 | 01-NOV-04:06 |
December | 827.22 | 01-DEC-10:09 | 658.76 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1596.90 | 21-DEC-23:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 438.10 | |||||
Maximum of Months | 827.22 | 658.76 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 334.54 | 1921.16 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1040.56 | 02-JAN-16:49 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1027.00 | 13-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 972.69 | 06-FEB-16:00 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1346.19 | 23-FEB-24:00 |
March | 1306.65 | 01-MAR-10:09 | 769.18 | 21-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 2881.75 | 19-MAR-07:00 |
April | 1306.65 | 03-APR-09:09 | 673.29 | 03-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1857.43 | 15-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 496.34 | 01-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 54.30 | 17-MAY-14:50 | 1038.69 | 03-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 496.34 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 320.37 | 25-JUN-17:54 | 654.76 | 08-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 496.34 | 03-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 499.08 | 16-JUL-11:54 | 650.75 | 03-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 543.37 | 28-AUG-15:00 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 171.41 | 02-AUG-16:00 | 887.22 | 27-AUG-18:00 |
September | 1306.65 | 01-SEP-09:09 | 542.97 | 21-SEP-15:00 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 181.37 | 10-SEP-15:00 | 708.27 | 21-SEP-23:00 |
October | 1306.65 | 02-OCT-09:09 | 878.91 | 30-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.46 | 11-OCT-14:00 | 1524.74 | 29-OCT-09:00 |
November | 1306.65 | 01-NOV-09:09 | 1040.56 | 06-NOV-16:49 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1611.38 | 01-NOV-04:04 |
December | 1306.65 | 01-DEC-10:09 | 1040.56 | 01-DEC-16:30 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2395.41 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 496.34 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 650.75 | |||||
Maximum of Months | 1306.65 | 1040.56 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 499.08 | 2881.75 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 658.71 | 02-JAN-16:49 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 673.46 | 12-JAN-22:03 |
February | 827.17 | 01-FEB-10:09 | 614.32 | 06-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 872.66 | 23-FEB-24:00 |
March | 827.17 | 01-MAR-10:09 | 498.44 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1921.16 | 19-MAR-07:00 |
April | 827.17 | 03-APR-09:09 | 444.61 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1238.28 | 15-APR-05:00 |
May | 827.17 | 01-MAY-09:09 | 314.21 | 01-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 36.20 | 17-MAY-14:50 | 698.44 | 03-MAY-03:00 |
June | 827.17 | 01-JUN-09:09 | 337.36 | 16-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 194.72 | 25-JUN-18:00 | 463.29 | 08-JUN-23:00 |
July | 827.17 | 03-JUL-09:09 | 334.18 | 28-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 332.89 | 16-JUL-11:54 | 447.31 | 03-JUL-03:00 |
August | 827.17 | 01-AUG-09:09 | 345.27 | 21-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 114.27 | 02-AUG-16:00 | 596.16 | 27-AUG-18:00 |
September | 827.17 | 01-SEP-09:09 | 357.99 | 22-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 120.91 | 10-SEP-15:00 | 465.48 | 21-SEP-23:00 |
October | 827.17 | 02-OCT-09:09 | 562.41 | 30-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 16.72 | 11-OCT-14:00 | 989.20 | 29-OCT-09:00 |
November | 827.17 | 01-NOV-09:09 | 658.71 | 06-NOV-16:49 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1066.23 | 01-NOV-04:06 |
December | 827.17 | 01-DEC-10:09 | 658.71 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1596.91 | 21-DEC-23:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 447.31 | |||||
Maximum of Months | 827.17 | 658.71 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 332.89 | 1921.16 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1040.56 | 02-JAN-16:49 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 587.06 | 13-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 971.69 | 06-FEB-16:00 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 703.96 | 23-FEB-24:00 |
March | 1306.65 | 01-MAR-10:09 | 767.76 | 21-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.19 | 14-MAR-13:00 | 1555.00 | 19-MAR-06:55 |
April | 1306.65 | 03-APR-09:09 | 585.81 | 03-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1040.17 | 15-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 496.34 | 01-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 29.33 | 17-MAY-14:50 | 586.63 | 03-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 496.34 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 166.15 | 25-JUN-18:00 | 357.72 | 08-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 496.34 | 03-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 261.99 | 16-JUL-11:52 | 346.86 | 03-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 542.56 | 28-AUG-15:00 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 91.82 | 02-AUG-16:00 | 417.16 | 27-AUG-18:00 |
September | 1306.65 | 01-SEP-09:09 | 548.23 | 21-SEP-15:00 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 108.15 | 10-SEP-15:00 | 416.03 | 22-SEP-02:00 |
October | 1306.65 | 02-OCT-09:09 | 881.29 | 30-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.56 | 11-OCT-14:00 | 925.97 | 29-OCT-09:00 |
November | 1306.65 | 01-NOV-09:09 | 1040.56 | 06-NOV-16:49 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 878.97 | 01-NOV-03:55 |
December | 1306.65 | 01-DEC-10:09 | 1040.56 | 01-DEC-16:30 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 1.30 | 02-DEC-15:00 | 1322.25 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 346.86 | |||||
Maximum of Months | 1306.65 | 1040.56 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 261.99 | 1555.00 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.22 | 02-JAN-10:09 | 658.76 | 02-JAN-16:49 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 402.41 | 13-JAN-05:00 |
February | 827.22 | 01-FEB-10:09 | 615.58 | 06-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 496.42 | 23-FEB-24:00 |
March | 827.22 | 01-MAR-10:09 | 465.28 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14-MAR-13:00 | 1034.42 | 19-MAR-06:55 |
April | 827.22 | 03-APR-09:09 | 364.40 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 706.64 | 15-APR-05:00 |
May | 827.22 | 01-MAY-09:09 | 314.23 | 01-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.55 | 17-MAY-14:50 | 401.42 | 03-MAY-03:00 |
June | 827.22 | 01-JUN-09:09 | 314.23 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 112.26 | 25-JUN-17:54 | 250.02 | 08-JUN-23:00 |
July | 827.22 | 03-JUL-09:09 | 314.23 | 03-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 172.92 | 16-JUL-11:52 | 246.33 | 03-JUL-03:00 |
August | 827.22 | 01-AUG-09:09 | 347.68 | 28-AUG-15:00 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.21 | 02-AUG-16:00 | 301.93 | 27-AUG-18:00 |
September | 827.22 | 01-SEP-09:09 | 351.87 | 21-SEP-15:00 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 67.86 | 10-SEP-14:34 | 280.45 | 22-SEP-02:00 |
October | 827.22 | 02-OCT-09:09 | 548.83 | 30-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.04 | 11-OCT-14:00 | 634.01 | 29-OCT-09:00 |
November | 827.22 | 01-NOV-09:09 | 658.76 | 06-NOV-16:49 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 582.62 | 01-NOV-03:55 |
December | 827.22 | 01-DEC-10:09 | 658.76 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 877.97 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.22 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 246.33 | |||||
Maximum of Months | 827.22 | 658.76 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 172.92 | 1034.42 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1040.56 | 02-JAN-16:49 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 27356.32 | 05-JAN-17:01 |
February | 1306.65 | 01-FEB-10:09 | 970.10 | 06-FEB-16:00 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 21567.29 | 02-FEB-07:01 |
March | 1306.65 | 01-MAR-10:09 | 758.74 | 21-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 20740.39 | 02-MAR-07:01 |
April | 1306.65 | 03-APR-09:09 | 584.95 | 03-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 20130.51 | 17-APR-06:01 |
May | 1306.65 | 01-MAY-09:09 | 496.34 | 01-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 2552.44 | 31-MAY-16:10 | 13933.67 | 02-MAY-06:02 |
June | 1306.65 | 01-JUN-09:09 | 496.34 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 8963.05 | 26-JUN-16:03 | 8634.65 | 09-JUN-06:02 |
July | 1306.65 | 03-JUL-09:09 | 496.34 | 03-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 6946.63 | 17-JUL-11:03 | 8282.89 | 03-JUL-06:01 |
August | 1306.65 | 01-AUG-09:09 | 538.71 | 28-AUG-15:00 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 7878.69 | 16-AUG-16:03 | 7496.24 | 17-AUG-06:02 |
September | 1306.65 | 01-SEP-09:09 | 538.24 | 21-SEP-15:00 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 4263.36 | 12-SEP-16:05 | 16000.58 | 21-SEP-16:01 |
October | 1306.65 | 02-OCT-09:09 | 872.67 | 30-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 664.11 | 10-OCT-16:50 | 21924.84 | 30-OCT-06:01 |
November | 1306.65 | 01-NOV-09:09 | 1040.56 | 06-NOV-16:49 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 23612.91 | 29-NOV-17:01 |
December | 1306.65 | 01-DEC-10:09 | 1040.56 | 01-DEC-16:30 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 32662.10 | 21-DEC-17:01 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 496.34 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7496.24 | |||||
Maximum of Months | 1306.65 | 1040.56 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 8963.05 | 32662.10 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 658.71 | 02-JAN-16:49 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 405.05 | 13-JAN-05:00 |
February | 827.17 | 01-FEB-10:09 | 612.93 | 06-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 497.58 | 23-FEB-24:00 |
March | 827.17 | 01-MAR-10:09 | 493.55 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.01 | 14-MAR-13:00 | 1031.98 | 19-MAR-06:55 |
April | 827.17 | 03-APR-09:09 | 438.10 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 695.46 | 15-APR-05:00 |
May | 827.17 | 01-MAY-09:09 | 314.21 | 01-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 19.55 | 17-MAY-14:50 | 411.15 | 03-MAY-03:00 |
June | 827.17 | 01-JUN-09:09 | 334.46 | 16-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 104.63 | 25-JUN-18:00 | 262.47 | 08-JUN-23:00 |
July | 827.17 | 03-JUL-09:09 | 314.21 | 03-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 172.89 | 16-JUL-11:52 | 255.04 | 03-JUL-03:00 |
August | 827.17 | 01-AUG-09:09 | 343.12 | 21-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 61.21 | 02-AUG-16:00 | 328.89 | 27-AUG-18:00 |
September | 827.17 | 01-SEP-09:09 | 356.14 | 22-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 64.97 | 10-SEP-15:00 | 277.96 | 22-SEP-02:00 |
October | 827.17 | 02-OCT-09:09 | 559.46 | 30-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 9.04 | 11-OCT-14:00 | 625.83 | 29-OCT-09:00 |
November | 827.17 | 01-NOV-09:09 | 658.71 | 06-NOV-16:49 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 581.79 | 01-NOV-03:55 |
December | 827.17 | 01-DEC-10:09 | 658.71 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 883.83 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 255.04 | |||||
Maximum of Months | 827.17 | 658.71 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 172.89 | 1031.98 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1040.56 | 02-JAN-16:49 | 1435.25 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 919.09 | 13-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 974.19 | 06-FEB-16:00 | 1435.25 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1132.45 | 23-FEB-24:00 |
March | 1306.65 | 01-MAR-10:09 | 777.76 | 21-MAR-07:10 | 1435.25 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 2396.85 | 19-MAR-07:00 |
April | 1306.65 | 03-APR-09:09 | 678.85 | 03-APR-07:10 | 1435.25 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1599.15 | 15-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 496.34 | 01-MAY-07:10 | 1435.25 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.56 | 17-MAY-14:50 | 930.83 | 03-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 496.34 | 01-JUN-07:10 | 1435.25 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 255.19 | 25-JUN-17:44 | 566.41 | 08-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 496.34 | 03-JUL-07:10 | 1435.25 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 404.86 | 16-JUL-11:52 | 558.76 | 03-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 546.99 | 28-AUG-15:00 | 1435.25 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.22 | 02-AUG-16:00 | 684.35 | 27-AUG-18:00 |
September | 1306.65 | 01-SEP-09:09 | 552.39 | 21-SEP-15:00 | 1435.25 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 155.38 | 10-SEP-14:35 | 626.34 | 22-SEP-02:00 |
October | 1306.65 | 02-OCT-09:09 | 887.10 | 30-OCT-07:10 | 1435.25 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 21.05 | 11-OCT-14:00 | 1379.03 | 29-OCT-09:00 |
November | 1306.65 | 01-NOV-09:09 | 1040.56 | 06-NOV-16:49 | 1435.25 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1336.55 | 01-NOV-04:04 |
December | 1306.65 | 01-DEC-10:09 | 1040.56 | 01-DEC-16:30 | 1435.25 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2027.12 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 558.76 | |||||
Maximum of Months | 1306.65 | 1040.56 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 404.86 | 2396.85 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 805.43 | 02-JAN-08:09 | 658.76 | 02-JAN-16:49 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 613.98 | 13-JAN-05:00 |
February | 805.43 | 01-FEB-08:09 | 616.85 | 06-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 765.93 | 23-FEB-24:00 |
March | 805.43 | 01-MAR-08:09 | 471.30 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1597.89 | 19-MAR-07:00 |
April | 805.43 | 03-APR-07:10 | 366.21 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1062.92 | 15-APR-05:00 |
May | 805.43 | 01-MAY-07:10 | 314.23 | 01-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.37 | 17-MAY-14:50 | 621.44 | 03-MAY-03:00 |
June | 805.43 | 01-JUN-07:10 | 314.23 | 01-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 185.59 | 25-JUN-17:43 | 378.27 | 08-JUN-23:00 |
July | 805.43 | 03-JUL-07:10 | 314.23 | 03-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 270.00 | 16-JUL-11:52 | 389.48 | 02-JUL-08:40 |
August | 805.43 | 01-AUG-07:10 | 350.07 | 28-AUG-15:00 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.48 | 02-AUG-16:00 | 469.73 | 27-AUG-18:00 |
September | 805.43 | 01-SEP-07:10 | 354.08 | 21-SEP-15:00 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 105.77 | 10-SEP-14:34 | 417.01 | 22-SEP-02:00 |
October | 805.43 | 02-OCT-07:10 | 552.22 | 30-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 13.76 | 11-OCT-14:10 | 923.19 | 29-OCT-09:00 |
November | 805.43 | 01-NOV-07:10 | 658.76 | 06-NOV-16:49 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 886.45 | 01-NOV-04:06 |
December | 805.43 | 01-DEC-08:09 | 658.76 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1343.13 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 378.27 | |||||
Maximum of Months | 805.43 | 658.76 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 270.00 | 1597.89 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 1306.65 | 02-JAN-10:09 | 1040.56 | 02-JAN-16:49 | 1435.24 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 953.10 | 13-JAN-05:00 |
February | 1306.65 | 01-FEB-10:09 | 972.68 | 06-FEB-16:00 | 1435.24 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1194.53 | 23-FEB-24:00 |
March | 1306.65 | 01-MAR-10:09 | 769.15 | 21-MAR-07:10 | 1435.24 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 2396.86 | 19-MAR-07:00 |
April | 1306.65 | 03-APR-09:09 | 673.25 | 03-APR-07:10 | 1435.24 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1607.34 | 15-APR-05:00 |
May | 1306.65 | 01-MAY-09:09 | 496.34 | 01-MAY-07:10 | 1435.24 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 45.56 | 17-MAY-14:50 | 941.70 | 03-MAY-03:00 |
June | 1306.65 | 01-JUN-09:09 | 496.34 | 01-JUN-07:10 | 1435.24 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 254.40 | 25-JUN-17:43 | 564.71 | 08-JUN-23:00 |
July | 1306.65 | 03-JUL-09:09 | 496.34 | 03-JUL-07:10 | 1435.24 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 404.91 | 16-JUL-11:52 | 560.34 | 03-JUL-03:00 |
August | 1306.65 | 01-AUG-09:09 | 543.36 | 28-AUG-15:00 | 1435.24 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 143.22 | 02-AUG-16:00 | 743.25 | 27-AUG-18:00 |
September | 1306.65 | 01-SEP-09:09 | 542.95 | 21-SEP-15:00 | 1435.24 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 151.78 | 10-SEP-14:34 | 629.34 | 22-SEP-02:00 |
October | 1306.65 | 02-OCT-09:09 | 878.90 | 30-OCT-07:10 | 1435.24 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 15.62 | 11-OCT-14:00 | 1408.91 | 29-OCT-09:00 |
November | 1306.65 | 01-NOV-09:09 | 1040.56 | 06-NOV-16:49 | 1435.24 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1329.68 | 01-NOV-04:06 |
December | 1306.65 | 01-DEC-10:09 | 1040.56 | 01-DEC-16:30 | 1435.24 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2056.97 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 1306.65 | 496.34 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 560.34 | |||||
Maximum of Months | 1306.65 | 1040.56 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 404.91 | 2396.86 |
Report: PeakSpaceGainsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] | ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} | ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 827.17 | 02-JAN-10:09 | 658.71 | 02-JAN-16:49 | 908.57 | 02-JAN-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 617.74 | 13-JAN-05:00 |
February | 827.17 | 01-FEB-10:09 | 614.32 | 06-FEB-16:00 | 908.57 | 01-FEB-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 776.34 | 23-FEB-24:00 |
March | 827.17 | 01-MAR-10:09 | 498.42 | 21-MAR-07:10 | 908.57 | 01-MAR-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 1597.89 | 19-MAR-07:00 |
April | 827.17 | 03-APR-09:09 | 444.59 | 03-APR-07:10 | 908.57 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 1059.71 | 15-APR-05:00 |
May | 827.17 | 01-MAY-09:09 | 314.21 | 01-MAY-07:10 | 908.57 | 01-MAY-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 30.37 | 17-MAY-14:50 | 632.53 | 03-MAY-03:00 |
June | 827.17 | 01-JUN-09:09 | 337.35 | 16-JUN-07:10 | 908.57 | 01-JUN-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 174.26 | 25-JUN-17:43 | 397.96 | 08-JUN-23:00 |
July | 827.17 | 03-JUL-09:09 | 334.17 | 28-JUL-07:10 | 908.57 | 03-JUL-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 269.94 | 16-JUL-11:52 | 385.14 | 03-JUL-03:00 |
August | 827.17 | 01-AUG-09:09 | 345.27 | 21-AUG-07:10 | 908.57 | 01-AUG-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 95.48 | 02-AUG-16:00 | 499.53 | 27-AUG-18:00 |
September | 827.17 | 01-SEP-09:09 | 357.99 | 22-SEP-07:10 | 908.57 | 01-SEP-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 101.18 | 10-SEP-15:00 | 414.60 | 22-SEP-02:00 |
October | 827.17 | 02-OCT-09:09 | 562.40 | 30-OCT-07:10 | 908.57 | 02-OCT-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 14.04 | 11-OCT-14:00 | 917.03 | 29-OCT-09:00 |
November | 827.17 | 01-NOV-09:09 | 658.71 | 06-NOV-16:49 | 908.57 | 01-NOV-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 886.45 | 01-NOV-04:06 |
December | 827.17 | 01-DEC-10:09 | 658.71 | 01-DEC-16:30 | 908.57 | 01-DEC-08:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 1352.13 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
Minimum of Months | 827.17 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 385.14 | |||||
Maximum of Months | 827.17 | 658.71 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 269.94 | 1597.89 |
Report: PeakSpaceGainsMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1356.32 | 13-JAN-05:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 1624.25 | 23-FEB-24:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 3431.97 | 19-MAR-06:55 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 2322.92 | 15-APR-05:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.50 | 17-MAY-14:40 | 1334.49 | 03-MAY-03:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 316.13 | 25-JUN-18:00 | 763.89 | 08-JUN-23:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 527.05 | 16-JUL-12:00 | 753.98 | 03-JUL-03:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 166.85 | 06-AUG-12:00 | 900.44 | 27-AUG-18:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 200.81 | 10-SEP-15:00 | 885.51 | 22-SEP-02:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.71 | 11-OCT-14:00 | 2008.49 | 29-OCT-09:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 1920.50 | 01-NOV-03:55 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 2826.24 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 753.98 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 527.05 | 3431.97 |
Report: PeakSpaceGainsMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1667.76 | 13-JAN-05:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2034.23 | 23-FEB-24:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 4210.18 | 19-MAR-06:55 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 2889.09 | 15-APR-05:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.26 | 17-MAY-14:40 | 1661.40 | 03-MAY-03:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 389.06 | 25-JUN-18:00 | 974.79 | 08-JUN-23:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 674.73 | 16-JUL-12:00 | 974.43 | 03-JUL-03:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 219.34 | 06-AUG-12:00 | 1143.00 | 27-AUG-18:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 263.52 | 10-SEP-15:00 | 1113.79 | 22-SEP-02:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.78 | 11-OCT-14:00 | 2433.05 | 29-OCT-09:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2302.90 | 01-NOV-03:55 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 3528.27 | 21-DEC-22:55 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 974.43 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 674.73 | 4210.18 |
Report: PeakSpaceGainsMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP} | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-JAN-00:10 | 1512.77 | 31-JAN-02:00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-FEB-00:10 | 2038.28 | 19-FEB-17:00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-MAR-00:10 | 4186.32 | 19-MAR-07:00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-APR-00:10 | 2779.63 | 15-APR-05:00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 50.86 | 17-MAY-13:00 | 1523.18 | 03-MAY-03:00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 285.40 | 25-JUN-17:40 | 968.47 | 08-JUN-23:00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 597.76 | 16-JUL-12:00 | 961.00 | 03-JUL-03:00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 205.65 | 02-AUG-16:00 | 1325.48 | 27-AUG-18:00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.02 | 10-SEP-14:30 | 1060.06 | 21-SEP-23:00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.97 | 11-OCT-14:00 | 2295.68 | 29-OCT-09:00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-NOV-00:10 | 2202.45 | 01-NOV-04:00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 01-DEC-00:10 | 3641.71 | 21-DEC-23:00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 961.00 | ||
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 597.76 | 4186.32 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 17847.82 | 26-JAN-16:40 | 6035.01 | 4936.01 | 14392.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 17230.35 | 28-FEB-09:00 | 12070.02 | 9872.03 | 36370.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 36950.23 | 15-MAR-06:02 | 7623.17 | 9872.16 | 52780.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 19215.47 | 13-APR-08:00 | 6035.01 | 4936.01 | 18185.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 36272.35 | 22-MAY-06:03 | 5082.11 | 6581.44 | 35187.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 40602.78 | 26-JUN-05:12 | 3176.32 | 2742.16 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 41593.93 | 24-JUL-05:12 | 3176.32 | 2742.16 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 41915.86 | 28-AUG-05:12 | 3176.32 | 2742.16 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 41163.82 | 05-SEP-05:12 | 3176.32 | 2742.16 | 24947.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 38834.22 | 10-OCT-06:01 | 10164.22 | 13162.88 | 70374.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 36778.23 | 09-NOV-07:01 | 8893.70 | 11517.52 | 61577.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 16199.11 | 05-DEC-09:00 | 12070.02 | 9872.03 | 36370.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 16199.11 | 3176.32 | 2742.16 | 14392.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 41915.86 | 12070.02 | 13162.88 | 70374.38 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3269.06 | 20-JAN-15:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 40.54 |
February | 3095.25 | 18-FEB-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 67.14 |
March | 7249.90 | 14-MAR-14:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 36.12 |
April | 6348.91 | 21-APR-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.26 |
May | 8986.18 | 31-MAY-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.43 | 0.00 |
June | 12354.93 | 26-JUN-13:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.71 | 0.00 |
July | 10863.58 | 17-JUL-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.61 | 0.00 |
August | 12178.53 | 16-AUG-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.05 | 0.00 |
September | 9212.40 | 12-SEP-14:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.68 | 0.00 |
October | 7156.11 | 11-OCT-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.36 | 0.00 |
November | 4333.08 | 09-NOV-13:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 9.40 |
December | 1963.94 | 01-DEC-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 18.72 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 1963.94 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12354.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 185.61 | 147.26 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3038.74 | 05-JAN-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 451.98 |
February | 2396.95 | 10-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 297.91 |
March | 2762.44 | 15-MAR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.01 |
April | 2906.52 | 15-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 671.62 |
May | 2838.89 | 18-MAY-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.20 |
June | 5676.64 | 26-JUN-15:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.21 | 0.00 |
July | 5961.45 | 17-JUL-10:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 90.10 | 0.00 |
August | 5105.49 | 21-AUG-14:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 30.38 | 0.00 |
September | 4931.67 | 05-SEP-15:40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.03 |
October | 3305.03 | 11-OCT-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.43 |
November | 2510.55 | 30-NOV-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1308.57 |
December | 3492.94 | 20-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1653.11 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2396.95 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 5961.45 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 117.21 | 1653.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY [] | ZONE LIGHTS TOTAL HEATING ENERGY [] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2750.10 | 06-JAN-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 664.38 |
February | 2568.10 | 02-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 178.80 |
March | 3092.00 | 15-MAR-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.60 |
April | 2160.91 | 26-APR-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 134.12 |
May | 3088.39 | 18-MAY-15:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 20.63 |
June | 6650.85 | 26-JUN-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 51.01 | 0.00 |
July | 6685.25 | 17-JUL-12:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.74 | 0.00 |
August | 5256.22 | 21-AUG-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.47 | 0.00 |
September | 5208.83 | 05-SEP-16:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 8.40 |
October | 3936.55 | 11-OCT-16:20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.65 |
November | 2167.15 | 08-NOV-15:50 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 32.45 |
December | 3001.59 | 21-DEC-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 1229.29 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 2160.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 6685.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.74 | 1229.29 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 10121.53 | 25-JAN-16:20 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 9454.97 | 27-FEB-16:30 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 14172.49 | 15-MAR-16:00 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 12683.84 | 21-APR-14:00 | 6198.29 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 15168.51 | 18-MAY-06:03 | 5082.11 | 6581.44 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 29911.41 | 19-JUN-05:12 | 2541.06 | 2193.73 | 12103.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 30382.33 | 10-JUL-05:12 | 3176.32 | 2742.16 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 30753.38 | 07-AUG-05:12 | 3176.32 | 2742.16 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 31554.50 | 05-SEP-05:12 | 3176.32 | 2742.16 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 27260.48 | 10-OCT-06:01 | 10164.22 | 13162.88 | 24207.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 12368.22 | 08-NOV-16:30 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 8064.50 | 15-DEC-16:00 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 8064.50 | 2541.06 | 2193.73 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 31554.50 | 10164.22 | 13162.88 | 24207.36 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [] | |
January | 9215.56 | 20-JAN-16:30 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 8360.03 | 27-FEB-16:20 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 15161.74 | 15-MAR-15:20 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 14099.46 | 21-APR-14:00 | 6198.29 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16172.75 | 31-MAY-16:00 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 32114.91 | 26-JUN-05:12 | 3176.32 | 2742.16 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 32725.81 | 24-JUL-05:12 | 3176.32 | 2742.16 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 32422.22 | 21-AUG-05:12 | 3176.32 | 2742.16 | 15129.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 30159.38 | 05-SEP-06:02 | 7623.17 | 9872.16 | 18155.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 15946.75 | 11-OCT-15:30 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 11525.16 | 08-NOV-16:00 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 6621.50 | 15-DEC-16:00 | 6035.01 | 4936.01 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |||||
Minimum of Months | 6621.50 | 3176.32 | 2742.16 | 6808.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 32725.81 | 7623.17 | 9872.16 | 18155.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1427.41 | 20-JAN-14:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.03 |
February | 1191.78 | 27-FEB-13:40 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 218.11 |
March | 3664.01 | 14-MAR-14:30 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.06 |
April | 3685.35 | 20-APR-13:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.44 |
May | 5730.03 | 17-MAY-13:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 44.26 | 0.00 |
June | 11642.04 | 25-JUN-17:51 | 0.00 | 193.02 | 2702.72 | 0.00 | 0.00 | 0.00 | 0.00 | 273.01 | 0.00 |
July | 11719.53 | 16-JUL-14:32 | 334.80 | 137.87 | 2392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 397.71 | 0.00 |
August | 8329.60 | 20-AUG-15:41 | 468.72 | 193.02 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 27.12 | 0.00 |
September | 7980.41 | 03-SEP-15:32 | 334.80 | 137.87 | 2392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.26 |
October | 4095.28 | 11-OCT-14:40 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 22.55 | 0.00 |
November | 2370.36 | 09-NOV-13:40 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 |
December | 1121.90 | 01-DEC-13:40 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.42 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1121.90 | 0.00 | 137.87 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 11719.53 | 1306.65 | 496.34 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 397.71 | 218.11 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 2635.54 | 20-JAN-09:50 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 49.91 |
February | 3685.78 | 27-FEB-09:20 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.42 |
March | 8013.30 | 12-MAR-09:32 | 169.56 | 69.83 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 448.09 |
April | 7247.06 | 21-APR-08:50 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.83 |
May | 8096.68 | 28-MAY-09:32 | 169.56 | 69.83 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 107.91 |
June | 11119.78 | 11-JUN-09:02 | 211.95 | 87.28 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 126.88 |
July | 13969.47 | 16-JUL-09:12 | 254.35 | 104.74 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 98.33 | 0.00 |
August | 14025.56 | 06-AUG-09:12 | 254.35 | 104.74 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.83 |
September | 11498.22 | 04-SEP-09:22 | 211.95 | 87.28 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 24.81 |
October | 7884.34 | 01-OCT-09:13 | 169.56 | 69.83 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 433.58 |
November | 3672.12 | 07-NOV-09:10 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 38.19 |
December | 904.91 | 01-DEC-09:40 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.56 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 904.91 | 169.56 | 69.83 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14025.56 | 805.43 | 314.23 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 98.33 | 448.09 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 13204.96 | 20-JAN-13:30 | 1272.23 | 496.34 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.32 |
February | 16275.65 | 26-FEB-13:22 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 390.95 |
March | 17545.94 | 12-MAR-12:52 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 712.66 |
April | 9502.61 | 21-APR-13:10 | 2613.31 | 992.69 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 78.16 |
May | 8401.86 | 16-MAY-13:10 | 2613.31 | 992.69 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 28.68 | 0.00 |
June | 15614.07 | 25-JUN-15:11 | 468.72 | 193.02 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 104.00 | 0.00 |
July | 16023.35 | 23-JUL-13:32 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 201.47 | 0.00 |
August | 16022.17 | 06-AUG-12:32 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 94.58 | 0.00 |
September | 17136.19 | 04-SEP-13:22 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 46.86 | 0.00 |
October | 18915.42 | 09-OCT-13:31 | 535.68 | 220.59 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 105.10 |
November | 18321.08 | 05-NOV-13:51 | 468.72 | 193.02 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 59.32 |
December | 16953.25 | 17-DEC-13:12 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 427.83 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 8401.86 | 334.80 | 137.87 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 18915.42 | 2613.31 | 992.69 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 201.47 | 712.66 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 5031.72 | 20-JAN-15:40 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.76 |
February | 5388.12 | 17-FEB-16:30 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 42.59 |
March | 15972.37 | 12-MAR-16:12 | 254.33 | 104.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 205.43 |
April | 8602.23 | 07-APR-16:00 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.03 |
May | 9552.87 | 28-MAY-15:23 | 169.55 | 69.82 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 118.07 |
June | 16932.14 | 25-JUN-16:31 | 339.11 | 139.64 | 2422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 98.38 | 0.00 |
July | 16617.77 | 02-JUL-17:01 | 0.00 | 122.19 | 1710.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.65 |
August | 16249.56 | 13-AUG-16:42 | 254.33 | 104.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 71.84 |
September | 16522.30 | 10-SEP-16:01 | 296.72 | 122.19 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 41.42 | 0.00 |
October | 16790.50 | 09-OCT-16:11 | 296.72 | 122.19 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 84.35 |
November | 7533.69 | 05-NOV-15:53 | 169.55 | 69.82 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.76 |
December | 3757.73 | 01-DEC-15:30 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.13 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3757.73 | 0.00 | 69.82 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16932.14 | 805.38 | 314.21 | 2422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 98.38 | 205.43 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1295.42 | 20-JAN-14:10 | 2613.31 | 992.69 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 |
February | 1181.13 | 22-FEB-13:05 | 7633.40 | 2978.07 | 8611.48 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.25 |
March | 1732.56 | 14-MAR-15:00 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.58 |
April | 1573.76 | 20-APR-13:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.48 |
May | 3893.86 | 17-MAY-13:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 23.78 | 0.00 |
June | 6937.10 | 26-JUN-06:03 | 803.52 | 496.35 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.74 |
July | 8854.88 | 16-JUL-14:21 | 468.72 | 193.02 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 217.54 | 0.00 |
August | 5481.50 | 21-AUG-14:00 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 22.61 | 0.00 |
September | 6468.46 | 11-SEP-06:03 | 1071.35 | 915.98 | 2551.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.25 |
October | 3399.16 | 11-OCT-14:30 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 12.68 | 0.00 |
November | 2024.34 | 09-NOV-13:30 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.99 |
December | 1190.82 | 03-DEC-15:23 | 267.84 | 144.00 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 108.52 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1181.13 | 267.84 | 144.00 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 8854.88 | 7633.40 | 2978.07 | 8611.48 | 0.00 | 0.00 | 0.00 | 0.00 | 217.54 | 108.52 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1787.59 | 20-JAN-09:50 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.41 |
February | 3067.61 | 27-FEB-08:35 | 1610.86 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 37.06 |
March | 4699.91 | 15-MAR-09:10 | 1654.44 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.83 |
April | 4981.75 | 21-APR-09:00 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.52 |
May | 6593.24 | 11-MAY-06:03 | 678.26 | 418.98 | 1615.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 34.55 |
June | 8413.53 | 08-JUN-06:02 | 847.82 | 523.72 | 2019.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 12.85 |
July | 11980.14 | 16-JUL-09:01 | 339.13 | 139.65 | 2422.86 | 0.00 | 0.00 | 0.00 | 0.00 | 49.72 | 0.00 |
August | 12044.48 | 06-AUG-09:01 | 339.13 | 139.65 | 2422.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.80 |
September | 11008.17 | 04-SEP-09:01 | 296.74 | 122.20 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.17 |
October | 7139.78 | 09-OCT-10:12 | 211.95 | 87.28 | 1514.29 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 29.39 |
November | 3449.06 | 07-NOV-08:25 | 1610.86 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 23.69 |
December | 1287.40 | 18-DEC-08:45 | 1610.86 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.99 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1287.40 | 211.95 | 87.28 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 12044.48 | 1654.44 | 628.45 | 2422.86 | 0.00 | 0.00 | 0.00 | 0.00 | 49.72 | 66.99 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 11194.32 | 22-JAN-14:53 | 267.84 | 110.30 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 364.23 |
February | 10682.35 | 26-FEB-13:02 | 267.84 | 110.30 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 188.79 |
March | 13252.95 | 12-MAR-12:52 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 350.61 |
April | 5832.51 | 12-APR-13:30 | 1306.65 | 496.34 | 1435.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 283.40 |
May | 6849.54 | 16-MAY-12:00 | 687.71 | 496.34 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 1993.06 | 0.00 |
June | 11478.16 | 26-JUN-12:00 | 687.71 | 496.34 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 6903.05 | 0.00 |
July | 12242.29 | 16-JUL-14:21 | 468.72 | 193.02 | 3348.89 | 0.00 | 0.00 | 0.00 | 0.00 | 218.21 | 0.00 |
August | 13051.79 | 27-AUG-12:32 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.69 |
September | 13454.24 | 04-SEP-13:01 | 535.68 | 220.59 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 25.19 | 0.00 |
October | 14818.35 | 09-OCT-13:31 | 535.68 | 220.59 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 54.86 |
November | 13272.63 | 05-NOV-13:22 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.69 |
December | 13507.32 | 17-DEC-14:42 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.25 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 5832.51 | 267.84 | 110.30 | 1275.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 14818.35 | 1306.65 | 496.34 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 6903.05 | 364.23 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3742.72 | 23-JAN-16:10 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.25 |
February | 3987.14 | 17-FEB-16:30 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 22.53 |
March | 10443.10 | 12-MAR-16:12 | 254.33 | 104.73 | 1817.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 102.03 |
April | 6956.35 | 08-APR-17:06 | 211.94 | 87.28 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 143.61 |
May | 6172.32 | 31-MAY-16:00 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 12.15 | 0.00 |
June | 12809.27 | 25-JUN-16:31 | 339.11 | 139.64 | 2422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 63.85 | 0.00 |
July | 12622.50 | 01-JUL-17:41 | 296.72 | 122.19 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 15.54 | 0.00 |
August | 12472.47 | 13-AUG-17:42 | 0.00 | 104.73 | 1466.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 19.86 |
September | 13797.55 | 10-SEP-17:11 | 0.00 | 157.10 | 2199.77 | 0.00 | 0.00 | 0.00 | 0.00 | 10.58 | 0.00 |
October | 13143.23 | 09-OCT-16:11 | 296.72 | 122.19 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 45.08 |
November | 5425.95 | 07-NOV-15:40 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.36 |
December | 3042.82 | 04-DEC-15:30 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 26.89 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3042.82 | 0.00 | 87.28 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 13797.55 | 805.38 | 314.21 | 2422.85 | 0.00 | 0.00 | 0.00 | 0.00 | 63.85 | 143.61 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 1446.38 | 20-JAN-15:10 | 2544.47 | 1069.98 | 2870.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.19 |
February | 1398.70 | 27-FEB-12:00 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.12 |
March | 3515.47 | 14-MAR-14:40 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 5.20 |
April | 3346.18 | 20-APR-13:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.25 |
May | 5396.71 | 17-MAY-13:30 | 1306.65 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 37.04 | 0.00 |
June | 10154.52 | 25-JUN-17:01 | 0.00 | 275.74 | 3861.03 | 0.00 | 0.00 | 0.00 | 0.00 | 182.44 | 0.00 |
July | 9998.22 | 16-JUL-14:21 | 468.72 | 193.02 | 3348.91 | 0.00 | 0.00 | 0.00 | 0.00 | 325.67 | 0.00 |
August | 7096.34 | 21-AUG-06:03 | 803.52 | 496.35 | 1913.66 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.69 |
September | 7417.49 | 04-SEP-15:52 | 334.80 | 137.87 | 2392.08 | 0.00 | 0.00 | 0.00 | 0.00 | 32.69 | 0.00 |
October | 3957.40 | 10-OCT-15:20 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 4.15 | 0.00 |
November | 2576.15 | 09-NOV-13:30 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.71 |
December | 1285.84 | 14-DEC-13:40 | 1272.23 | 496.34 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 21.19 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 1285.84 | 0.00 | 137.87 | 1435.25 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 10154.52 | 2544.47 | 1069.98 | 3861.03 | 0.00 | 0.00 | 0.00 | 0.00 | 325.67 | 61.12 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 3766.21 | 26-JAN-13:02 | 4027.14 | 1571.14 | 4542.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.57 |
February | 4892.32 | 27-FEB-09:05 | 1610.86 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.92 |
March | 9613.22 | 12-MAR-09:43 | 169.56 | 69.83 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 395.36 |
April | 7608.22 | 21-APR-08:30 | 805.43 | 314.23 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 61.54 |
May | 9446.15 | 28-MAY-09:02 | 169.56 | 69.83 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 147.52 |
June | 14229.57 | 11-JUN-08:12 | 254.35 | 104.74 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 131.44 |
July | 14814.12 | 23-JUL-08:41 | 296.74 | 122.20 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 57.64 |
August | 15284.59 | 06-AUG-09:01 | 339.13 | 139.65 | 2422.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.72 |
September | 14439.87 | 04-SEP-09:11 | 296.74 | 122.20 | 2120.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 41.65 |
October | 9864.48 | 01-OCT-09:23 | 169.56 | 69.83 | 1211.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 372.08 |
November | 4744.40 | 07-NOV-09:00 | 1610.86 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 33.51 |
December | 2085.57 | 14-DEC-11:05 | 1610.86 | 628.45 | 1817.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 46.79 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 2085.57 | 169.56 | 69.83 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 27.57 | |
Maximum of Months | 15284.59 | 4027.14 | 1571.14 | 4542.87 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 395.36 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 14747.13 | 22-JAN-11:32 | 267.84 | 110.30 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 593.17 |
February | 14986.20 | 26-FEB-12:42 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 326.83 |
March | 14874.23 | 12-MAR-12:22 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 325.30 |
April | 9055.18 | 21-APR-13:05 | 2613.31 | 992.69 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 64.86 |
May | 7855.37 | 16-MAY-13:10 | 2613.31 | 992.69 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 24.07 | 0.00 |
June | 14297.57 | 25-JUN-16:21 | 669.60 | 275.74 | 4784.12 | 0.00 | 0.00 | 0.00 | 0.00 | 147.97 | 0.00 |
July | 14444.73 | 23-JUL-12:42 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 95.45 | 0.00 |
August | 15186.19 | 27-AUG-12:32 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 103.39 |
September | 16408.38 | 04-SEP-13:13 | 535.68 | 220.59 | 3827.30 | 0.00 | 0.00 | 0.00 | 0.00 | 40.15 | 0.00 |
October | 15754.63 | 09-OCT-13:02 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 60.29 |
November | 15542.98 | 05-NOV-12:42 | 401.76 | 165.44 | 2870.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 25.93 |
December | 14893.86 | 17-DEC-12:52 | 334.80 | 137.87 | 2392.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 363.65 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 7855.37 | 267.84 | 110.30 | 1913.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16408.38 | 2613.31 | 992.69 | 4784.12 | 0.00 | 0.00 | 0.00 | 0.00 | 147.97 | 593.17 |
Report: SpaceGainComponentsAtCoolingPeakMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] | ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} | ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] | ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] | ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] | ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] | ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] | ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W] | |
January | 4968.70 | 20-JAN-15:40 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.57 |
February | 5397.26 | 17-FEB-16:30 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 35.37 |
March | 9826.47 | 12-MAR-16:22 | 211.94 | 87.28 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 175.99 |
April | 10070.39 | 08-APR-17:06 | 211.94 | 87.28 | 1514.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 226.83 |
May | 9240.31 | 28-MAY-15:13 | 169.55 | 69.82 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 100.09 |
June | 16748.91 | 25-JUN-16:21 | 423.88 | 174.55 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 51.15 | 0.00 |
July | 15304.46 | 02-JUL-16:41 | 296.72 | 122.19 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 2.90 | 0.00 |
August | 14871.92 | 20-AUG-15:41 | 296.72 | 122.19 | 2119.99 | 0.00 | 0.00 | 0.00 | 0.00 | 5.12 | 0.00 |
September | 16207.25 | 10-SEP-17:11 | 0.00 | 157.10 | 2199.77 | 0.00 | 0.00 | 0.00 | 0.00 | 13.59 | 0.00 |
October | 13821.17 | 09-OCT-17:02 | 0.00 | 87.28 | 1222.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 66.03 |
November | 7242.32 | 05-NOV-16:03 | 169.55 | 69.82 | 1211.42 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 120.63 |
December | 3719.76 | 01-DEC-15:30 | 805.38 | 314.21 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 13.35 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | |||||||
Minimum of Months | 3719.76 | 0.00 | 69.82 | 908.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 16748.91 | 805.38 | 314.21 | 3028.56 | 0.00 | 0.00 | 0.00 | 0.00 | 51.15 | 226.83 |
Report: EnergyConsumptionElectricityNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportELECTRICITY:FACILITY [J] | ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | NATURALGAS:FACILITY [J] | NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | |
January | 0.110782E+12 | 166382.40 | 05-JAN-07:10 | 0.423477E+11 | 100735.78 | 05-JAN-07:00 |
February | 0.105462E+12 | 201790.88 | 06-FEB-07:10 | 0.408328E+11 | 77273.64 | 02-FEB-07:30 |
March | 0.110393E+12 | 173900.12 | 20-MAR-06:10 | 0.322625E+11 | 68100.49 | 29-MAR-06:19 |
April | 0.961431E+11 | 162928.79 | 03-APR-06:10 | 0.234546E+11 | 69648.79 | 17-APR-06:40 |
May | 0.104706E+12 | 120612.27 | 31-MAY-15:39 | 0.127113E+11 | 39507.48 | 02-MAY-06:40 |
June | 0.143606E+12 | 181077.66 | 26-JUN-15:09 | 0.109002E+11 | 9940.25 | 01-JUN-11:30 |
July | 0.140138E+12 | 163324.98 | 17-JUL-10:50 | 0.105618E+11 | 9832.43 | 03-JUL-11:50 |
August | 0.145080E+12 | 161800.06 | 16-AUG-15:09 | 0.109805E+11 | 9781.83 | 30-AUG-11:09 |
September | 0.119987E+12 | 141579.64 | 12-SEP-15:39 | 0.112015E+11 | 38543.34 | 21-SEP-19:00 |
October | 0.107058E+12 | 160059.72 | 30-OCT-06:10 | 0.249562E+11 | 81707.70 | 30-OCT-06:00 |
November | 0.104032E+12 | 149053.08 | 30-NOV-07:10 | 0.345759E+11 | 86671.57 | 29-NOV-20:00 |
December | 0.122810E+12 | 199302.41 | 26-DEC-07:10 | 0.522638E+11 | 101490.73 | 21-DEC-09:39 |
Annual Sum or Average | 0.141020E+13 | 0.307049E+12 | ||||
Minimum of Months | 0.961431E+11 | 120612.27 | 0.105618E+11 | 9781.83 | ||
Maximum of Months | 0.145080E+12 | 201790.88 | 0.522638E+11 | 101490.73 |
Report: EndUseEnergyConsumptionElectricityMonthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [J] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 0.199484E+11 | 0.576619E+10 | 0.593559E+11 | 0.982924E+09 | 0.479495E+10 | 12379742.02 | 0.183783E+11 | 0.154295E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.178034E+11 | 0.464601E+10 | 0.537310E+11 | 0.889314E+09 | 0.454113E+10 | 11196021.66 | 0.226953E+11 | 0.114506E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.208158E+11 | 0.436023E+10 | 0.617796E+11 | 0.102906E+10 | 0.621200E+10 | 12675672.10 | 0.134964E+11 | 0.268742E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.184093E+11 | 0.352061E+10 | 0.572952E+11 | 0.946211E+09 | 0.514247E+10 | 11960507.72 | 0.839026E+10 | 0.242721E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.197375E+11 | 0.315424E+10 | 0.605677E+11 | 0.100555E+10 | 0.862042E+10 | 12527707.06 | 0.954341E+09 | 0.106540E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.195897E+11 | 0.285754E+10 | 0.594895E+11 | 0.989880E+09 | 0.189207E+11 | 12231776.97 | 11417023.65 | 0.417353E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.183421E+11 | 0.302979E+10 | 0.583622E+11 | 0.961670E+09 | 0.178367E+11 | 12256437.81 | 3281793.21 | 0.415903E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.205580E+11 | 0.340742E+10 | 0.617796E+11 | 0.102892E+10 | 0.182402E+11 | 12675672.10 | 1228554.13 | 0.400516E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.184650E+11 | 0.388526E+10 | 0.572729E+11 | 0.945999E+09 | 0.134531E+11 | 11960507.72 | 0.186597E+09 | 0.257663E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.194795E+11 | 0.481774E+10 | 0.593671E+11 | 0.982608E+09 | 0.703174E+10 | 12379742.02 | 0.921723E+10 | 0.615002E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.196941E+11 | 0.537119E+10 | 0.580818E+11 | 0.964728E+09 | 0.516695E+10 | 12059151.09 | 0.124182E+11 | 0.232270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.194031E+11 | 0.596407E+10 | 0.583511E+11 | 0.962373E+09 | 0.483924E+10 | 12256437.81 | 0.321934E+11 | 0.108461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.232246E+12 | 0.507803E+11 | 0.705434E+12 | 0.116892E+11 | 0.114800E+12 | 0.146559E+09 | 0.117946E+12 | 0.177157E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.178034E+11 | 0.285754E+10 | 0.537310E+11 | 0.889314E+09 | 0.454113E+10 | 11196021.66 | 1228554.13 | 0.108461E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.208158E+11 | 0.596407E+10 | 0.617796E+11 | 0.102906E+10 | 0.189207E+11 | 12675672.10 | 0.321934E+11 | 0.417353E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: EndUseEnergyConsumptionNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | HUMIDIFIER:NATURALGAS [] | |
January | 0.00 | 0.00 | 0.305144E+11 | 0.00 | 0.118333E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.300450E+11 | 0.00 | 0.107878E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.200054E+11 | 0.00 | 0.122571E+11 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.122510E+11 | 0.00 | 0.112035E+11 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.125226E+10 | 0.00 | 0.114591E+11 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 1517335.16 | 0.00 | 0.108986E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.105618E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.109805E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.833705E+09 | 0.00 | 0.103678E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.140000E+11 | 0.00 | 0.109563E+11 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.235740E+11 | 0.00 | 0.110020E+11 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.408099E+11 | 0.00 | 0.114540E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.173287E+12 | 0.00 | 0.133762E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.103678E+11 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.408099E+11 | 0.00 | 0.122571E+11 | 0.00 | 0.00 |
Report: PeakEnergyEndUseElectricityPart1Monthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportINTERIORLIGHTS:ELECTRICITY {Maximum} [W] | INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] | EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} | INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | EXTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] | EXTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} | FANS:ELECTRICITY {Maximum} [W] | FANS:ELECTRICITY {TIMESTAMP} | PUMPS:ELECTRICITY {Maximum} [W] | PUMPS:ELECTRICITY {TIMESTAMP} | HEATING:ELECTRICITY {Maximum} [W] | HEATING:ELECTRICITY {TIMESTAMP} | |
January | 25003.79 | 02-JAN-16:49 | 5686.19 | 01-JAN-06:10 | 45864.70 | 02-JAN-08:09 | 838.79 | 02-JAN-16:00 | 8445.92 | 20-JAN-16:10 | 6.85 | 06-JAN-12:09 | 126633.00 | 05-JAN-07:10 |
February | 24334.46 | 06-FEB-16:00 | 5686.19 | 01-FEB-06:10 | 45864.70 | 01-FEB-08:09 | 837.60 | 06-FEB-16:00 | 8188.17 | 27-FEB-15:30 | 6.85 | 02-FEB-06:10 | 166145.31 | 06-FEB-07:10 |
March | 22326.73 | 21-MAR-07:10 | 5686.19 | 01-MAR-06:10 | 45864.70 | 01-MAR-08:09 | 836.59 | 21-MAR-07:19 | 19595.56 | 15-MAR-15:00 | 6.85 | 01-MAR-06:10 | 139491.62 | 20-MAR-06:10 |
April | 21107.22 | 03-APR-07:10 | 5686.19 | 01-APR-05:10 | 45864.70 | 03-APR-07:10 | 834.97 | 03-APR-07:19 | 12211.28 | 21-APR-13:30 | 6.85 | 04-APR-05:10 | 129161.48 | 03-APR-06:10 |
May | 19671.42 | 01-MAY-07:10 | 3328.83 | 01-MAY-18:49 | 45864.70 | 01-MAY-07:10 | 833.07 | 01-MAY-07:19 | 19143.96 | 31-MAY-15:39 | 6.85 | 01-MAY-05:19 | 54885.37 | 01-MAY-06:10 |
June | 19737.96 | 16-JUN-07:10 | 3328.83 | 01-JUN-19:19 | 45864.70 | 01-JUN-07:10 | 833.16 | 16-JUN-07:19 | 33595.95 | 26-JUN-15:09 | 6.85 | 04-JUN-15:09 | 4832.60 | 09-JUN-06:19 |
July | 19711.36 | 28-JUL-07:10 | 3328.83 | 01-JUL-19:30 | 45864.70 | 03-JUL-07:10 | 833.12 | 28-JUL-07:19 | 35100.38 | 24-JUL-15:20 | 6.85 | 02-JUL-14:00 | 1308.32 | 03-JUL-06:00 |
August | 20060.48 | 28-AUG-15:00 | 5686.19 | 10-AUG-05:10 | 45864.70 | 01-AUG-07:10 | 833.19 | 21-AUG-07:19 | 30026.42 | 11-AUG-14:00 | 6.85 | 06-AUG-08:20 | 920.10 | 23-AUG-06:10 |
September | 20087.88 | 21-SEP-15:00 | 5686.19 | 01-SEP-05:10 | 45864.70 | 01-SEP-07:10 | 833.40 | 22-SEP-07:19 | 28044.25 | 05-SEP-15:39 | 6.85 | 02-SEP-17:10 | 27146.61 | 22-SEP-06:10 |
October | 23431.59 | 30-OCT-07:10 | 5686.19 | 01-OCT-05:10 | 45864.70 | 02-OCT-07:10 | 838.06 | 30-OCT-07:19 | 19183.64 | 11-OCT-15:00 | 6.85 | 02-OCT-11:09 | 120397.12 | 30-OCT-06:10 |
November | 25003.79 | 06-NOV-16:49 | 5686.19 | 01-NOV-05:10 | 45864.70 | 01-NOV-07:10 | 838.79 | 06-NOV-16:00 | 10899.51 | 07-NOV-15:00 | 6.85 | 01-NOV-05:10 | 115233.11 | 30-NOV-07:10 |
December | 25003.79 | 01-DEC-16:30 | 5686.19 | 01-DEC-06:10 | 45864.70 | 01-DEC-08:09 | 838.79 | 01-DEC-16:40 | 6209.93 | 15-DEC-15:09 | 6.85 | 05-DEC-06:10 | 158498.32 | 26-DEC-07:10 |
Annual Sum or Average | ||||||||||||||
Minimum of Months | 19671.42 | 3328.83 | 45864.70 | 833.07 | 6209.93 | 6.85 | 920.10 | |||||||
Maximum of Months | 25003.79 | 5686.19 | 45864.70 | 838.79 | 35100.38 | 6.85 | 166145.31 |
Report: PeakEnergyEndUseElectricityPart2Monthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportCOOLING:ELECTRICITY {Maximum} [W] | COOLING:ELECTRICITY {TIMESTAMP} | HEATREJECTION:ELECTRICITY [] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
January | 16801.96 | 20-JAN-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 10811.76 | 18-FEB-13:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 26523.26 | 14-MAR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 18326.18 | 20-APR-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 38885.91 | 31-MAY-15:39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 84899.31 | 26-JUN-15:09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 70307.21 | 17-JUL-12:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 71311.98 | 16-AUG-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 53551.85 | 12-SEP-15:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 38918.99 | 11-OCT-14:30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 20931.44 | 07-NOV-14:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 15402.61 | 01-DEC-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 10811.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 84899.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ElectricComponentsOfPeakDemandMonthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY [] | |
January | 166382.40 | 05-JAN-07:10 | 8334.71 | 21098.80 | 5686.19 | 243.70 | 4379.16 | 6.85 | 126633.00 | 0.00 | 0.00 |
February | 201790.88 | 06-FEB-07:10 | 8334.71 | 21098.80 | 0.00 | 243.70 | 5961.51 | 6.85 | 166145.31 | 0.00 | 0.00 |
March | 173900.12 | 20-MAR-06:10 | 8334.71 | 21098.80 | 0.00 | 243.70 | 4724.44 | 6.85 | 139491.62 | 0.00 | 0.00 |
April | 162928.79 | 03-APR-06:10 | 7903.23 | 21098.80 | 0.00 | 243.65 | 4514.78 | 6.85 | 129161.48 | 0.00 | 0.00 |
May | 120612.27 | 31-MAY-15:39 | 19671.42 | 42072.41 | 0.00 | 831.72 | 19143.96 | 6.85 | 0.00 | 38885.91 | 0.00 |
June | 181077.66 | 26-JUN-15:09 | 19671.42 | 42072.41 | 0.00 | 831.72 | 33595.95 | 6.85 | 0.00 | 84899.31 | 0.00 |
July | 163324.98 | 17-JUL-10:50 | 19671.42 | 41577.77 | 0.00 | 831.54 | 33231.55 | 6.85 | 0.00 | 68005.86 | 0.00 |
August | 161800.06 | 16-AUG-15:09 | 19671.42 | 42072.41 | 0.00 | 831.72 | 28482.49 | 6.85 | 0.00 | 70735.18 | 0.00 |
September | 141579.64 | 12-SEP-15:39 | 19671.42 | 42072.41 | 0.00 | 831.72 | 25859.38 | 6.85 | 0.00 | 53137.86 | 0.00 |
October | 160059.72 | 30-OCT-06:10 | 8334.71 | 21098.80 | 5686.19 | 243.70 | 4292.35 | 6.85 | 120397.12 | 0.00 | 0.00 |
November | 149053.08 | 30-NOV-07:10 | 8334.71 | 21098.80 | 0.00 | 243.70 | 4135.91 | 6.85 | 115233.11 | 0.00 | 0.00 |
December | 199302.41 | 26-DEC-07:10 | 8334.71 | 21098.80 | 5686.19 | 243.70 | 5433.84 | 6.85 | 158498.32 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | ||||||||||
Minimum of Months | 120612.27 | 7903.23 | 21098.80 | 0.00 | 243.65 | 4135.91 | 6.85 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 201790.88 | 19671.42 | 42072.41 | 5686.19 | 831.72 | 33595.95 | 6.85 | 166145.31 | 84899.31 | 0.00 |
Report: PeakEnergyEndUseNaturalGasMonthly
For: Meter
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportINTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {Maximum} [W] | HEATING:NATURALGAS {TIMESTAMP} | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {Maximum} [W] | WATERSYSTEMS:NATURALGAS {TIMESTAMP} | COGENERATION:NATURALGAS [] | |
January | 0.00 | 0.00 | 92027.92 | 05-JAN-07:30 | 0.00 | 10265.74 | 27-JAN-12:00 | 0.00 |
February | 0.00 | 0.00 | 68379.24 | 02-FEB-07:30 | 0.00 | 10507.47 | 14-FEB-12:30 | 0.00 |
March | 0.00 | 0.00 | 60067.32 | 02-MAR-07:19 | 0.00 | 10383.28 | 02-MAR-12:20 | 0.00 |
April | 0.00 | 0.00 | 61397.73 | 17-APR-06:30 | 0.00 | 10183.34 | 03-APR-11:20 | 0.00 |
May | 0.00 | 0.00 | 31914.47 | 02-MAY-06:19 | 0.00 | 10071.65 | 01-MAY-11:09 | 0.00 |
June | 0.00 | 0.00 | 1661.56 | 09-JUN-06:10 | 0.00 | 9940.25 | 01-JUN-11:30 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 9832.43 | 03-JUL-11:50 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 9781.83 | 30-AUG-11:09 | 0.00 |
September | 0.00 | 0.00 | 33572.11 | 22-SEP-06:30 | 0.00 | 9840.25 | 29-SEP-11:39 | 0.00 |
October | 0.00 | 0.00 | 72873.45 | 30-OCT-06:00 | 0.00 | 9966.17 | 31-OCT-11:09 | 0.00 |
November | 0.00 | 0.00 | 77859.14 | 29-NOV-20:00 | 0.00 | 10084.50 | 28-NOV-12:09 | 0.00 |
December | 0.00 | 0.00 | 92027.92 | 21-DEC-08:09 | 0.00 | 10189.86 | 29-DEC-12:09 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 9781.83 | 0.00 | ||
Maximum of Months | 0.00 | 0.00 | 92027.92 | 0.00 | 10507.47 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.16 | 0.00 | 26.16 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.17 | 26.16 | 0.00 | 26.16 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 26.16 | 0.00 | 26.16 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.17 | 19.36 | 0.17 | 19.36 | 0.00 | 19.36 | 0.00 | 19.36 |
Annual Sum or Average | 0.17 | 19.36 | 0.17 | 19.36 | 0.00 | 19.36 | 0.00 | 19.36 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.17 | 19.36 | 0.17 | 19.36 | 0.00 | 19.36 | 0.00 | 19.36 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 17.15 | 0.00 | 17.15 | 0.00 | 17.15 | 0.00 | 17.15 |
February | 0.67 | 18.13 | 0.33 | 18.50 | 0.00 | 18.50 | 0.00 | 18.50 |
March | 0.17 | 19.44 | 0.17 | 19.44 | 0.00 | 19.44 | 0.00 | 19.44 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.50 | 18.97 | 0.50 | 18.97 | 0.00 | 18.97 | 0.00 | 18.97 |
Annual Sum or Average | 1.50 | 18.45 | 1.00 | 18.72 | 0.00 | 18.72 | 0.00 | 18.72 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.67 | 19.44 | 0.50 | 19.44 | 0.00 | 19.44 | 0.00 | 19.44 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 5.83 | 16.32 | 2.00 | 16.63 | 0.00 | 16.63 | 0.00 | 16.63 |
February | 18.50 | 15.83 | 7.83 | 16.16 | 0.00 | 16.16 | 0.00 | 16.16 |
March | 5.33 | 15.12 | 2.00 | 15.04 | 0.00 | 15.04 | 0.00 | 15.04 |
April | 3.17 | 16.84 | 1.00 | 17.49 | 0.00 | 17.49 | 0.00 | 17.49 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 4.17 | 27.52 | 2.67 | 27.51 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 | 27.58 | 5.83 | 27.59 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 1.17 | 27.32 | 1.17 | 27.32 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 1.33 | 27.33 | 1.33 | 27.33 |
October | 3.17 | 16.34 | 0.67 | 16.88 | 0.00 | 16.88 | 0.00 | 16.88 |
November | 2.83 | 16.93 | 0.67 | 17.41 | 0.00 | 17.41 | 0.00 | 17.41 |
December | 32.17 | 16.14 | 12.67 | 16.71 | 0.00 | 16.71 | 0.00 | 16.71 |
Annual Sum or Average | 71.00 | 16.07 | 26.83 | 16.50 | 14.17 | 17.89 | 11.00 | 18.75 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 32.17 | 16.93 | 12.67 | 17.49 | 7.50 | 27.58 | 5.83 | 27.59 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 3.83 | 15.67 | 0.17 | 15.64 | 0.00 | 15.64 | 0.00 | 15.64 |
February | 14.33 | 14.99 | 3.67 | 14.98 | 0.00 | 14.98 | 0.00 | 14.98 |
March | 6.17 | 15.01 | 1.83 | 14.87 | 0.67 | 15.84 | 0.67 | 16.67 |
April | 2.67 | 15.45 | 0.00 | 15.45 | 0.00 | 15.45 | 0.00 | 15.45 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.51 | 0.83 | 27.51 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 11.50 | 27.83 | 10.17 | 27.85 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 17.00 | 28.08 | 15.33 | 28.11 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 28.01 | 7.33 | 28.03 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 7.50 | 27.70 | 7.00 | 27.72 |
October | 3.17 | 15.48 | 0.00 | 15.48 | 1.33 | 19.04 | 1.33 | 20.97 |
November | 2.33 | 15.85 | 0.00 | 15.85 | 0.00 | 15.85 | 0.00 | 15.85 |
December | 21.00 | 14.81 | 2.50 | 14.85 | 0.00 | 14.85 | 0.00 | 14.85 |
Annual Sum or Average | 53.50 | 15.06 | 8.17 | 15.04 | 46.50 | 20.57 | 42.67 | 22.66 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.85 | 0.00 | 14.85 |
Maximum of Months | 21.00 | 15.85 | 3.67 | 15.85 | 17.00 | 28.08 | 15.33 | 28.11 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 1.83 | 16.49 | 0.00 | 16.49 | 1.00 | 20.44 | 1.00 | 22.33 |
February | 11.67 | 15.19 | 4.00 | 15.25 | 1.67 | 16.46 | 1.67 | 17.47 |
March | 4.50 | 14.86 | 1.67 | 14.74 | 1.83 | 17.79 | 1.83 | 19.70 |
April | 2.17 | 15.75 | 0.17 | 16.01 | 0.00 | 16.01 | 0.00 | 16.01 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.33 | 27.27 | 0.33 | 27.27 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 27.69 | 6.17 | 27.71 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 11.00 | 27.83 | 9.83 | 27.85 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.67 | 27.91 | 6.33 | 27.92 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 11.50 | 27.38 | 10.67 | 27.38 |
October | 2.17 | 15.79 | 0.17 | 16.05 | 7.83 | 25.04 | 7.83 | 26.20 |
November | 1.33 | 16.45 | 0.00 | 16.45 | 3.67 | 24.93 | 3.67 | 26.23 |
December | 15.00 | 15.05 | 2.00 | 15.12 | 2.33 | 16.67 | 2.33 | 17.89 |
Annual Sum or Average | 38.67 | 15.27 | 8.00 | 15.30 | 55.17 | 22.03 | 51.67 | 23.96 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 16.01 | 0.00 | 16.01 |
Maximum of Months | 15.00 | 16.49 | 4.00 | 16.49 | 11.50 | 27.91 | 10.67 | 27.92 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 2.83 | 15.93 | 0.50 | 15.79 | 0.00 | 15.79 | 0.00 | 15.79 |
February | 14.17 | 14.99 | 4.33 | 14.98 | 0.00 | 14.98 | 0.00 | 14.98 |
March | 7.00 | 15.06 | 2.50 | 14.92 | 1.33 | 16.53 | 1.00 | 17.50 |
April | 2.83 | 15.41 | 0.00 | 15.41 | 0.17 | 16.12 | 0.17 | 16.75 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.57 | 3.00 | 27.56 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 9.83 | 28.53 | 5.50 | 28.58 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 12.67 | 28.14 | 8.50 | 28.17 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 28.21 | 4.00 | 28.24 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 7.67 | 28.23 | 5.50 | 28.27 |
October | 3.33 | 15.34 | 0.00 | 15.34 | 2.83 | 21.19 | 2.50 | 23.19 |
November | 2.17 | 15.95 | 0.00 | 15.95 | 0.33 | 17.49 | 0.33 | 18.67 |
December | 20.83 | 14.81 | 3.83 | 14.83 | 0.00 | 14.83 | 0.00 | 14.83 |
Annual Sum or Average | 53.17 | 15.06 | 11.17 | 15.03 | 44.50 | 20.41 | 30.50 | 22.12 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 14.83 | 0.00 | 14.83 |
Maximum of Months | 20.83 | 15.95 | 4.33 | 15.95 | 12.67 | 28.53 | 8.50 | 28.58 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 17.21 | 0.00 | 17.21 | 0.00 | 17.21 | 0.00 | 17.21 |
February | 2.83 | 19.27 | 2.33 | 19.51 | 0.00 | 19.51 | 0.00 | 19.51 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.50 | 27.38 | 0.50 | 27.38 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 1.83 | 18.69 | 1.17 | 19.09 | 0.00 | 19.09 | 0.00 | 19.09 |
Annual Sum or Average | 4.83 | 18.98 | 3.50 | 19.31 | 0.50 | 19.77 | 0.50 | 20.18 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.83 | 19.27 | 2.33 | 19.51 | 0.50 | 27.38 | 0.50 | 27.38 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.67 | 16.87 | 0.00 | 16.87 | 0.00 | 16.87 | 0.00 | 16.87 |
March | 0.17 | 17.22 | 0.00 | 17.22 | 0.00 | 17.22 | 0.00 | 17.22 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.56 | 5.50 | 27.57 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 14.00 | 27.70 | 13.67 | 27.71 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.00 | 27.78 | 6.00 | 27.78 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.59 | 5.67 | 27.59 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 1.67 | 27.41 | 1.67 | 27.41 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.67 | 16.84 | 0.00 | 16.84 | 0.00 | 16.84 | 0.00 | 16.84 |
Annual Sum or Average | 1.50 | 16.90 | 0.00 | 16.90 | 33.00 | 27.19 | 32.50 | 27.42 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.67 | 17.22 | 0.00 | 17.22 | 14.00 | 27.78 | 13.67 | 27.78 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 29.17 | 18.17 | 29.17 | 18.17 | 1.50 | 18.40 | 1.50 | 18.62 |
February | 33.33 | 18.17 | 32.83 | 18.18 | 1.50 | 18.39 | 1.50 | 18.59 |
March | 25.00 | 18.74 | 25.00 | 18.74 | 1.33 | 18.97 | 1.33 | 19.19 |
April | 16.33 | 18.68 | 16.33 | 18.68 | 0.00 | 18.68 | 0.00 | 18.68 |
May | 2.67 | 19.22 | 2.67 | 19.22 | 0.00 | 19.22 | 0.00 | 19.22 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.50 | 25.36 | 5.50 | 25.36 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 5.83 | 26.68 | 5.83 | 26.68 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 11.50 | 26.01 | 11.50 | 26.01 |
September | 1.00 | 19.44 | 1.00 | 19.44 | 14.17 | 25.82 | 13.17 | 26.20 |
October | 15.67 | 17.88 | 15.67 | 17.88 | 15.17 | 20.72 | 14.50 | 22.10 |
November | 24.50 | 18.41 | 24.50 | 18.41 | 6.33 | 19.36 | 6.33 | 20.11 |
December | 38.50 | 17.49 | 38.00 | 17.49 | 2.83 | 17.86 | 2.83 | 18.21 |
Annual Sum or Average | 186.17 | 18.18 | 185.17 | 18.18 | 65.67 | 19.44 | 64.00 | 20.35 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 17.86 | 0.00 | 18.21 |
Maximum of Months | 38.50 | 19.44 | 38.00 | 19.44 | 15.17 | 26.68 | 14.50 | 26.68 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.67 | 16.91 | 0.00 | 16.91 | 0.00 | 16.91 | 0.00 | 16.91 |
March | 0.17 | 17.21 | 0.00 | 17.21 | 0.50 | 25.05 | 0.33 | 25.93 |
April | 0.17 | 17.23 | 0.00 | 17.23 | 0.17 | 22.50 | 0.17 | 24.26 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.43 | 0.17 | 27.43 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 7.33 | 28.06 | 4.00 | 28.08 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 8.17 | 27.85 | 5.83 | 27.81 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 4.00 | 28.02 | 2.67 | 28.01 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 27.89 | 5.17 | 27.90 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 2.50 | 27.88 | 2.33 | 27.90 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.17 | 27.29 | 0.17 | 27.29 |
December | 0.67 | 16.87 | 0.00 | 16.87 | 0.00 | 16.87 | 0.00 | 16.87 |
Annual Sum or Average | 1.67 | 16.95 | 0.00 | 16.95 | 30.00 | 27.35 | 20.83 | 27.57 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.67 | 17.23 | 0.00 | 17.23 | 8.17 | 28.06 | 5.83 | 28.08 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 17.14 | 0.00 | 17.14 | 0.00 | 17.14 | 0.00 | 17.14 |
February | 2.17 | 18.11 | 1.17 | 18.65 | 0.00 | 18.65 | 0.00 | 18.65 |
March | 0.50 | 16.44 | 0.17 | 16.09 | 0.00 | 16.09 | 0.00 | 16.09 |
April | 0.33 | 17.06 | 0.00 | 17.06 | 0.00 | 17.06 | 0.00 | 17.06 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 1.83 | 27.42 | 1.33 | 27.41 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 3.33 | 27.52 | 2.83 | 27.53 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.17 | 17.16 | 0.00 | 17.16 | 0.00 | 17.16 | 0.00 | 17.16 |
November | 0.33 | 17.06 | 0.00 | 17.06 | 0.00 | 17.06 | 0.00 | 17.06 |
December | 5.17 | 16.55 | 2.17 | 17.02 | 0.00 | 17.02 | 0.00 | 17.02 |
Annual Sum or Average | 9.00 | 16.99 | 3.50 | 17.41 | 5.17 | 20.36 | 4.17 | 21.72 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 5.17 | 18.11 | 2.17 | 18.65 | 3.33 | 27.52 | 2.83 | 27.53 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 17.05 | 0.00 | 17.05 | 0.00 | 17.05 | 0.00 | 17.05 |
February | 1.67 | 15.78 | 0.00 | 15.78 | 0.00 | 15.78 | 0.00 | 15.78 |
March | 0.50 | 15.63 | 0.33 | 15.36 | 0.83 | 21.57 | 0.83 | 23.63 |
April | 0.33 | 17.00 | 0.00 | 17.00 | 0.50 | 23.25 | 0.50 | 24.81 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.83 | 27.77 | 0.83 | 27.77 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 10.33 | 27.73 | 10.00 | 27.74 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 16.00 | 27.99 | 15.17 | 28.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 6.50 | 28.05 | 6.50 | 28.05 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 6.33 | 27.77 | 6.17 | 27.78 |
October | 0.17 | 17.08 | 0.00 | 17.08 | 2.17 | 26.96 | 2.17 | 27.33 |
November | 0.33 | 16.99 | 0.00 | 16.99 | 0.00 | 16.99 | 0.00 | 16.99 |
December | 4.33 | 15.37 | 0.50 | 15.45 | 0.00 | 15.45 | 0.00 | 15.45 |
Annual Sum or Average | 7.67 | 15.73 | 0.83 | 15.72 | 43.50 | 25.89 | 42.17 | 26.79 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.45 | 0.00 | 15.45 |
Maximum of Months | 4.33 | 17.08 | 0.50 | 17.08 | 16.00 | 28.05 | 15.17 | 28.05 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.17 | 17.15 | 0.00 | 17.15 | 5.17 | 26.14 | 5.17 | 26.28 |
February | 1.17 | 16.27 | 0.00 | 16.27 | 2.33 | 24.06 | 2.33 | 25.62 |
March | 0.17 | 17.04 | 0.00 | 17.04 | 2.00 | 27.17 | 2.00 | 27.58 |
April | 0.33 | 17.06 | 0.00 | 17.06 | 0.00 | 17.06 | 0.00 | 17.06 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 5.33 | 27.54 | 5.00 | 27.55 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 9.83 | 27.64 | 9.50 | 27.64 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.67 | 27.82 | 5.67 | 27.82 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 12.33 | 27.16 | 11.67 | 27.16 |
October | 0.17 | 17.22 | 0.00 | 17.22 | 12.67 | 26.68 | 12.67 | 26.74 |
November | 0.33 | 17.12 | 0.00 | 17.12 | 8.67 | 26.39 | 8.67 | 26.57 |
December | 2.17 | 15.89 | 0.50 | 15.95 | 2.83 | 22.23 | 2.83 | 24.24 |
Annual Sum or Average | 4.50 | 16.30 | 0.50 | 16.30 | 66.83 | 26.47 | 65.50 | 26.83 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 2.17 | 17.22 | 0.50 | 17.22 | 12.67 | 27.82 | 12.67 | 27.82 |
Report: SetpointsNotMetWithTemperaturesMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.33 | 17.10 | 0.00 | 17.10 | 0.00 | 17.10 | 0.00 | 17.10 |
February | 1.83 | 15.72 | 0.00 | 15.72 | 0.17 | 16.69 | 0.17 | 17.50 |
March | 0.50 | 15.61 | 0.33 | 15.34 | 1.33 | 23.12 | 1.00 | 24.68 |
April | 0.33 | 16.96 | 0.00 | 16.96 | 0.17 | 20.67 | 0.17 | 22.53 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 2.83 | 27.55 | 2.50 | 27.54 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 8.67 | 28.40 | 4.83 | 28.48 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 10.50 | 28.06 | 7.67 | 28.04 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 5.17 | 28.19 | 3.33 | 28.23 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 7.00 | 28.15 | 5.17 | 28.18 |
October | 0.17 | 17.09 | 0.00 | 17.09 | 2.83 | 27.51 | 2.83 | 27.81 |
November | 0.33 | 17.00 | 0.00 | 17.00 | 0.33 | 22.29 | 0.33 | 24.05 |
December | 3.67 | 15.38 | 0.83 | 15.43 | 0.00 | 15.43 | 0.00 | 15.43 |
Annual Sum or Average | 7.17 | 15.75 | 1.17 | 15.71 | 39.00 | 25.94 | 28.00 | 26.76 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 15.43 | 0.00 | 15.43 |
Maximum of Months | 3.67 | 17.10 | 0.83 | 17.10 | 10.50 | 28.40 | 7.67 | 28.48 |
Report: ComfortReportSimple55Monthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 441.00 | 23.67 | 1.50 | 23.68 | 0.00 | 23.68 |
February | 386.67 | 23.63 | 1.00 | 23.62 | 1.00 | 23.61 |
March | 445.50 | 23.83 | 6.33 | 23.84 | 0.00 | 23.84 |
April | 331.83 | 23.91 | 13.00 | 23.96 | 0.00 | 23.96 |
May | 104.67 | 24.00 | 145.83 | 24.68 | 0.00 | 24.68 |
June | 0.50 | 24.00 | 313.50 | 24.58 | 0.50 | 24.58 |
July | 21.17 | 24.57 | 373.83 | 24.58 | 18.67 | 24.59 |
August | 0.50 | 24.00 | 350.17 | 24.58 | 0.00 | 24.58 |
September | 27.17 | 24.00 | 178.00 | 24.87 | 0.00 | 24.87 |
October | 209.33 | 23.97 | 57.50 | 24.31 | 0.00 | 24.31 |
November | 319.00 | 23.94 | 6.00 | 23.97 | 0.00 | 23.97 |
December | 489.17 | 23.58 | 16.33 | 23.51 | 16.33 | 23.44 |
Annual Sum or Average | 2776.50 | 23.78 | 1463.00 | 24.10 | 36.50 | 24.09 |
Minimum of Months | 0.50 | 23.58 | 1.00 | 23.51 | 0.00 | 23.44 |
Maximum of Months | 489.17 | 24.57 | 373.83 | 24.87 | 18.67 | 24.87 |
Report: ComfortReportSimple55Monthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: ComfortReportSimple55Monthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 498.67 | 22.50 | 64.17 | 22.29 | 64.17 | 22.13 |
February | 451.17 | 22.51 | 72.67 | 22.26 | 72.67 | 22.06 |
March | 490.67 | 22.92 | 29.83 | 22.79 | 29.83 | 22.67 |
April | 442.67 | 23.05 | 14.83 | 22.99 | 13.50 | 22.93 |
May | 197.83 | 23.74 | 44.67 | 23.91 | 0.00 | 23.91 |
June | 11.83 | 24.01 | 271.50 | 24.42 | 0.00 | 24.42 |
July | 35.83 | 24.25 | 319.33 | 24.44 | 26.00 | 24.43 |
August | 5.33 | 24.04 | 287.00 | 24.46 | 0.17 | 24.46 |
September | 118.00 | 23.92 | 116.00 | 24.39 | 0.00 | 24.39 |
October | 380.33 | 23.39 | 17.83 | 23.32 | 14.00 | 23.24 |
November | 463.33 | 22.97 | 8.67 | 22.93 | 8.67 | 22.89 |
December | 497.00 | 22.14 | 109.67 | 21.84 | 109.67 | 21.62 |
Annual Sum or Average | 3592.67 | 22.87 | 1356.17 | 23.08 | 338.67 | 22.94 |
Minimum of Months | 5.33 | 22.14 | 8.67 | 21.84 | 0.00 | 21.62 |
Maximum of Months | 498.67 | 24.25 | 319.33 | 24.46 | 109.67 | 24.46 |
Report: ComfortReportSimple55Monthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 21.60 | 171.00 | 21.25 | 171.00 | 21.04 |
February | 454.00 | 21.72 | 170.00 | 21.35 | 170.00 | 21.14 |
March | 506.67 | 22.32 | 100.00 | 21.96 | 100.00 | 21.71 |
April | 451.83 | 22.41 | 90.67 | 22.05 | 90.50 | 21.80 |
May | 267.50 | 23.50 | 31.67 | 23.54 | 4.00 | 23.50 |
June | 21.00 | 23.88 | 270.83 | 24.37 | 0.00 | 24.37 |
July | 30.33 | 24.19 | 314.50 | 24.42 | 25.17 | 24.41 |
August | 18.17 | 23.94 | 281.50 | 24.37 | 0.17 | 24.37 |
September | 159.83 | 23.65 | 91.83 | 24.04 | 0.00 | 24.04 |
October | 457.50 | 22.82 | 61.83 | 22.56 | 61.83 | 22.36 |
November | 485.67 | 22.11 | 100.83 | 21.87 | 100.83 | 21.71 |
December | 497.00 | 21.21 | 261.17 | 20.88 | 261.17 | 20.72 |
Annual Sum or Average | 3851.50 | 22.22 | 1945.83 | 22.29 | 984.67 | 22.02 |
Minimum of Months | 18.17 | 21.21 | 31.67 | 20.88 | 0.00 | 20.72 |
Maximum of Months | 506.67 | 24.19 | 314.50 | 24.42 | 261.17 | 24.41 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.47 | 339.00 | 20.22 | 339.00 | 20.12 |
February | 454.00 | 20.59 | 314.33 | 20.37 | 314.33 | 20.28 |
March | 514.00 | 21.40 | 232.00 | 20.98 | 232.00 | 20.76 |
April | 458.33 | 21.40 | 171.00 | 20.92 | 168.83 | 20.64 |
May | 278.50 | 22.88 | 86.83 | 23.07 | 17.33 | 22.95 |
June | 36.17 | 24.23 | 333.50 | 24.39 | 9.83 | 24.42 |
July | 65.33 | 24.54 | 368.33 | 24.51 | 47.67 | 24.54 |
August | 63.67 | 23.61 | 302.00 | 24.21 | 8.33 | 24.22 |
September | 208.83 | 23.15 | 107.50 | 23.58 | 9.50 | 23.50 |
October | 480.67 | 21.81 | 151.67 | 21.41 | 151.67 | 21.17 |
November | 487.50 | 20.97 | 281.50 | 20.70 | 281.50 | 20.57 |
December | 497.00 | 20.20 | 412.83 | 20.06 | 412.83 | 20.01 |
Annual Sum or Average | 4046.00 | 21.35 | 3100.50 | 21.49 | 1992.83 | 21.20 |
Minimum of Months | 36.17 | 20.20 | 86.83 | 20.06 | 8.33 | 20.01 |
Maximum of Months | 514.00 | 24.54 | 412.83 | 24.51 | 412.83 | 24.54 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 500.33 | 21.11 | 251.67 | 20.72 | 251.67 | 20.52 |
February | 432.83 | 21.25 | 215.33 | 20.80 | 215.33 | 20.57 |
March | 428.17 | 21.66 | 183.83 | 21.27 | 168.83 | 20.98 |
April | 372.00 | 21.48 | 168.50 | 21.12 | 136.50 | 20.77 |
May | 184.33 | 23.06 | 172.00 | 23.65 | 11.83 | 23.58 |
June | 43.67 | 26.19 | 411.00 | 24.64 | 36.33 | 24.79 |
July | 92.83 | 25.79 | 438.83 | 24.82 | 88.33 | 24.98 |
August | 54.17 | 25.19 | 398.33 | 24.51 | 29.17 | 24.64 |
September | 135.17 | 23.67 | 211.50 | 24.22 | 20.50 | 24.28 |
October | 379.17 | 21.93 | 160.50 | 21.78 | 122.17 | 21.48 |
November | 467.50 | 21.50 | 186.00 | 21.14 | 186.00 | 20.93 |
December | 497.00 | 20.70 | 315.50 | 20.35 | 315.50 | 20.19 |
Annual Sum or Average | 3587.17 | 21.75 | 3113.00 | 22.08 | 1582.17 | 21.79 |
Minimum of Months | 43.67 | 20.70 | 160.50 | 20.35 | 11.83 | 20.19 |
Maximum of Months | 500.33 | 26.19 | 438.83 | 24.82 | 315.50 | 24.98 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 357.17 | 21.38 | 243.83 | 21.42 | 171.50 | 21.13 |
February | 322.50 | 21.23 | 232.50 | 21.22 | 169.17 | 20.93 |
March | 376.33 | 21.57 | 214.67 | 21.42 | 166.67 | 21.15 |
April | 370.67 | 21.29 | 176.83 | 20.98 | 144.50 | 20.66 |
May | 240.67 | 22.80 | 133.67 | 23.25 | 16.83 | 23.14 |
June | 69.67 | 24.36 | 332.17 | 24.41 | 20.83 | 24.51 |
July | 96.33 | 24.81 | 375.50 | 24.59 | 64.33 | 24.69 |
August | 76.50 | 24.47 | 363.33 | 24.42 | 27.67 | 24.53 |
September | 152.67 | 23.77 | 235.33 | 24.23 | 32.67 | 24.35 |
October | 331.33 | 22.04 | 240.33 | 22.26 | 136.50 | 22.05 |
November | 333.33 | 21.73 | 231.67 | 21.90 | 144.83 | 21.64 |
December | 401.00 | 21.12 | 274.33 | 20.93 | 236.67 | 20.69 |
Annual Sum or Average | 3128.17 | 21.92 | 3054.17 | 22.37 | 1332.17 | 22.09 |
Minimum of Months | 69.67 | 21.12 | 133.67 | 20.93 | 16.83 | 20.66 |
Maximum of Months | 401.00 | 24.81 | 375.50 | 24.59 | 236.67 | 24.69 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 469.17 | 20.89 | 274.00 | 20.55 | 273.50 | 20.39 |
February | 411.83 | 20.94 | 258.83 | 20.66 | 249.50 | 20.49 |
March | 435.50 | 21.42 | 218.83 | 21.15 | 192.83 | 20.91 |
April | 386.17 | 21.27 | 184.67 | 20.97 | 153.00 | 20.67 |
May | 231.50 | 22.87 | 155.67 | 23.41 | 20.17 | 23.35 |
June | 66.33 | 24.82 | 365.67 | 24.52 | 27.83 | 24.65 |
July | 100.00 | 24.92 | 395.00 | 24.61 | 70.00 | 24.72 |
August | 75.17 | 24.33 | 364.83 | 24.40 | 26.17 | 24.49 |
September | 178.83 | 23.53 | 187.83 | 24.03 | 29.67 | 24.12 |
October | 401.50 | 21.79 | 192.67 | 21.70 | 145.33 | 21.45 |
November | 436.33 | 21.26 | 227.17 | 20.97 | 218.17 | 20.79 |
December | 481.83 | 20.58 | 349.00 | 20.29 | 348.67 | 20.18 |
Annual Sum or Average | 3674.17 | 21.61 | 3174.17 | 21.90 | 1754.83 | 21.62 |
Minimum of Months | 66.33 | 20.58 | 155.67 | 20.29 | 20.17 | 20.18 |
Maximum of Months | 481.83 | 24.92 | 395.00 | 24.61 | 348.67 | 24.72 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.67 | 319.67 | 20.49 | 319.67 | 20.42 |
February | 454.00 | 20.67 | 319.67 | 20.53 | 319.67 | 20.47 |
March | 514.00 | 21.28 | 240.33 | 20.98 | 240.33 | 20.83 |
April | 481.67 | 21.56 | 143.50 | 21.26 | 143.50 | 21.08 |
May | 374.50 | 23.15 | 31.33 | 23.12 | 13.17 | 23.05 |
June | 28.67 | 23.95 | 272.33 | 24.28 | 4.50 | 24.28 |
July | 44.00 | 24.05 | 322.00 | 24.37 | 36.83 | 24.34 |
August | 37.17 | 23.87 | 267.50 | 24.26 | 3.17 | 24.26 |
September | 178.67 | 23.59 | 104.00 | 24.00 | 0.00 | 24.00 |
October | 490.67 | 22.54 | 63.67 | 22.31 | 63.67 | 22.13 |
November | 489.00 | 21.52 | 156.50 | 21.31 | 156.50 | 21.18 |
December | 497.00 | 20.60 | 355.33 | 20.44 | 355.33 | 20.37 |
Annual Sum or Average | 4091.33 | 21.61 | 2595.83 | 21.71 | 1656.33 | 21.45 |
Minimum of Months | 28.67 | 20.60 | 31.33 | 20.44 | 0.00 | 20.37 |
Maximum of Months | 514.00 | 24.05 | 355.33 | 24.37 | 355.33 | 24.34 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 21.50 | 192.67 | 21.19 | 192.67 | 21.01 |
February | 436.50 | 21.54 | 188.33 | 21.14 | 188.33 | 20.92 |
March | 461.50 | 22.04 | 133.00 | 21.67 | 128.00 | 21.40 |
April | 402.83 | 22.12 | 103.83 | 21.85 | 90.33 | 21.59 |
May | 188.17 | 23.32 | 130.50 | 23.79 | 5.00 | 23.74 |
June | 14.33 | 26.38 | 421.67 | 24.56 | 14.33 | 24.61 |
July | 67.67 | 25.51 | 450.33 | 24.74 | 67.67 | 24.83 |
August | 24.83 | 26.33 | 426.33 | 24.58 | 22.17 | 24.68 |
September | 66.00 | 24.08 | 245.50 | 24.59 | 8.50 | 24.66 |
October | 331.83 | 22.66 | 102.50 | 22.73 | 56.00 | 22.51 |
November | 452.17 | 22.22 | 85.33 | 22.00 | 82.17 | 21.81 |
December | 497.00 | 21.30 | 255.33 | 20.95 | 255.33 | 20.77 |
Annual Sum or Average | 3444.83 | 22.11 | 2735.33 | 22.52 | 1110.50 | 22.27 |
Minimum of Months | 14.33 | 21.30 | 85.33 | 20.95 | 5.00 | 20.77 |
Maximum of Months | 502.00 | 26.38 | 450.33 | 24.74 | 255.33 | 24.83 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 366.17 | 21.72 | 159.33 | 21.78 | 96.17 | 21.48 |
February | 339.00 | 21.31 | 174.67 | 21.21 | 129.00 | 20.90 |
March | 402.83 | 21.57 | 150.33 | 21.29 | 135.33 | 21.02 |
April | 422.00 | 21.58 | 115.17 | 21.29 | 109.83 | 21.07 |
May | 330.83 | 22.74 | 55.50 | 22.90 | 13.67 | 22.81 |
June | 59.50 | 23.24 | 275.33 | 24.20 | 6.00 | 24.20 |
July | 78.50 | 23.85 | 344.50 | 24.38 | 46.33 | 24.36 |
August | 48.50 | 23.82 | 378.00 | 24.41 | 16.67 | 24.46 |
September | 87.67 | 23.77 | 272.67 | 24.51 | 21.00 | 24.64 |
October | 271.33 | 22.33 | 189.67 | 22.82 | 75.50 | 22.68 |
November | 298.33 | 21.92 | 163.00 | 22.39 | 60.67 | 22.16 |
December | 391.83 | 21.31 | 193.67 | 21.14 | 159.33 | 20.86 |
Annual Sum or Average | 3096.50 | 21.94 | 2471.83 | 22.50 | 869.50 | 22.24 |
Minimum of Months | 48.50 | 21.31 | 55.50 | 21.14 | 6.00 | 20.86 |
Maximum of Months | 422.00 | 23.85 | 378.00 | 24.51 | 159.33 | 24.64 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 483.33 | 21.36 | 206.50 | 21.06 | 206.33 | 20.89 |
February | 432.17 | 21.37 | 203.33 | 21.02 | 202.67 | 20.84 |
March | 462.83 | 21.78 | 159.00 | 21.43 | 153.33 | 21.19 |
April | 429.00 | 21.97 | 107.67 | 21.70 | 97.50 | 21.46 |
May | 249.50 | 23.24 | 106.17 | 23.61 | 5.67 | 23.57 |
June | 33.83 | 25.42 | 375.67 | 24.56 | 20.67 | 24.65 |
July | 49.50 | 24.85 | 405.00 | 24.56 | 49.17 | 24.59 |
August | 23.00 | 25.34 | 399.67 | 24.52 | 15.00 | 24.57 |
September | 95.00 | 24.13 | 217.17 | 24.57 | 14.83 | 24.68 |
October | 363.50 | 22.75 | 106.17 | 22.72 | 62.00 | 22.52 |
November | 437.33 | 22.12 | 86.83 | 21.92 | 82.17 | 21.75 |
December | 489.67 | 21.18 | 265.00 | 20.85 | 264.67 | 20.69 |
Annual Sum or Average | 3548.67 | 22.02 | 2638.17 | 22.37 | 1174.00 | 22.12 |
Minimum of Months | 23.00 | 21.18 | 86.83 | 20.85 | 5.67 | 20.69 |
Maximum of Months | 489.67 | 25.42 | 405.00 | 24.57 | 264.67 | 24.68 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 502.00 | 20.94 | 252.67 | 20.66 | 252.67 | 20.52 |
February | 454.00 | 20.95 | 252.50 | 20.69 | 252.50 | 20.56 |
March | 511.50 | 21.74 | 152.67 | 21.34 | 152.67 | 21.10 |
April | 461.50 | 21.94 | 108.83 | 21.58 | 106.83 | 21.33 |
May | 252.67 | 23.28 | 77.67 | 23.48 | 7.17 | 23.42 |
June | 11.33 | 24.23 | 353.67 | 24.42 | 4.33 | 24.42 |
July | 38.83 | 24.53 | 382.67 | 24.52 | 38.50 | 24.52 |
August | 27.67 | 23.88 | 314.00 | 24.33 | 4.83 | 24.33 |
September | 175.50 | 23.48 | 113.33 | 23.96 | 1.00 | 23.95 |
October | 477.00 | 22.39 | 78.33 | 22.10 | 78.33 | 21.88 |
November | 486.50 | 21.49 | 178.50 | 21.24 | 178.50 | 21.10 |
December | 497.00 | 20.58 | 335.50 | 20.36 | 335.50 | 20.27 |
Annual Sum or Average | 3895.50 | 21.70 | 2600.33 | 21.90 | 1412.83 | 21.62 |
Minimum of Months | 11.33 | 20.58 | 77.67 | 20.36 | 1.00 | 20.27 |
Maximum of Months | 511.50 | 24.53 | 382.67 | 24.52 | 335.50 | 24.52 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 416.67 | 21.44 | 169.67 | 21.09 | 168.67 | 20.89 |
February | 357.50 | 21.42 | 160.17 | 21.01 | 155.50 | 20.77 |
March | 359.83 | 21.86 | 122.00 | 21.54 | 106.67 | 21.24 |
April | 319.33 | 21.90 | 106.00 | 21.69 | 77.67 | 21.41 |
May | 141.00 | 23.38 | 152.00 | 24.01 | 6.67 | 23.99 |
June | 31.17 | 26.63 | 350.83 | 24.77 | 30.50 | 24.91 |
July | 80.50 | 25.94 | 374.50 | 24.97 | 80.50 | 25.12 |
August | 37.17 | 25.89 | 333.50 | 24.69 | 28.17 | 24.82 |
September | 102.33 | 23.98 | 180.50 | 24.53 | 14.17 | 24.64 |
October | 320.33 | 22.36 | 113.17 | 22.38 | 71.67 | 22.15 |
November | 383.33 | 21.85 | 115.00 | 21.58 | 110.33 | 21.38 |
December | 421.17 | 21.01 | 242.00 | 20.63 | 242.00 | 20.46 |
Annual Sum or Average | 2970.33 | 22.04 | 2419.33 | 22.44 | 1092.50 | 22.20 |
Minimum of Months | 31.17 | 21.01 | 106.00 | 20.63 | 6.67 | 20.46 |
Maximum of Months | 421.17 | 26.63 | 374.50 | 24.97 | 242.00 | 25.12 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 335.00 | 21.88 | 195.17 | 22.07 | 109.67 | 21.81 |
February | 305.50 | 21.62 | 205.17 | 21.68 | 132.50 | 21.38 |
March | 361.50 | 21.92 | 155.17 | 21.82 | 106.00 | 21.54 |
April | 367.33 | 21.91 | 114.67 | 21.71 | 85.67 | 21.43 |
May | 208.50 | 23.20 | 130.83 | 23.66 | 7.00 | 23.60 |
June | 29.83 | 24.92 | 352.00 | 24.47 | 14.00 | 24.53 |
July | 62.67 | 25.09 | 388.33 | 24.63 | 54.00 | 24.70 |
August | 39.33 | 25.31 | 386.33 | 24.52 | 22.50 | 24.61 |
September | 121.50 | 24.21 | 248.67 | 24.52 | 25.17 | 24.68 |
October | 310.17 | 22.60 | 203.00 | 22.90 | 88.83 | 22.77 |
November | 312.17 | 22.28 | 195.50 | 22.61 | 92.17 | 22.43 |
December | 388.33 | 21.63 | 238.33 | 21.49 | 192.67 | 21.25 |
Annual Sum or Average | 2841.83 | 22.30 | 2813.17 | 22.85 | 930.17 | 22.63 |
Minimum of Months | 29.83 | 21.62 | 114.67 | 21.49 | 7.00 | 21.25 |
Maximum of Months | 388.33 | 25.31 | 388.33 | 24.63 | 192.67 | 24.70 |
Report: ComfortReportSimple55Monthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] | ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] | |
January | 461.33 | 21.37 | 197.67 | 21.04 | 193.50 | 20.85 |
February | 402.67 | 21.29 | 203.67 | 21.00 | 191.17 | 20.79 |
March | 432.33 | 21.82 | 152.00 | 21.56 | 126.83 | 21.29 |
April | 383.33 | 21.87 | 120.33 | 21.67 | 89.83 | 21.40 |
May | 203.00 | 23.29 | 152.00 | 23.79 | 9.83 | 23.77 |
June | 40.83 | 25.61 | 382.00 | 24.59 | 26.33 | 24.71 |
July | 66.00 | 25.31 | 410.33 | 24.66 | 61.33 | 24.75 |
August | 38.67 | 25.12 | 383.33 | 24.51 | 23.00 | 24.59 |
September | 143.50 | 23.91 | 195.67 | 24.37 | 20.33 | 24.51 |
October | 390.00 | 22.40 | 128.83 | 22.40 | 77.83 | 22.20 |
November | 426.17 | 21.77 | 147.00 | 21.55 | 134.67 | 21.36 |
December | 477.67 | 20.97 | 284.33 | 20.65 | 282.17 | 20.49 |
Annual Sum or Average | 3465.50 | 21.97 | 2757.17 | 22.34 | 1236.83 | 22.09 |
Minimum of Months | 38.67 | 20.97 | 120.33 | 20.65 | 9.83 | 20.49 |
Maximum of Months | 477.67 | 25.61 | 410.33 | 24.66 | 282.17 | 24.75 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 23.77227 | 19.71681 | 0.08984 | 5.76471 |
February | 454.00000 | 23.76877 | 17.87100 | 0.07488 | 5.83711 |
March | 514.00000 | 23.95298 | 17.61999 | 0.14180 | 5.72266 |
April | 485.00000 | 24.07900 | 21.66647 | 0.19885 | 6.12793 |
May | 508.00000 | 24.40104 | 24.61035 | -0.5230 | 11.33510 |
June | 496.00000 | 24.38123 | 32.61001 | -0.4102 | 8.98398 |
July | 497.00000 | 24.45462 | 34.47205 | -0.3749 | 8.41994 |
August | 514.00000 | 24.40678 | 33.15679 | -0.3958 | 8.79806 |
September | 485.00000 | 24.43276 | 24.47188 | -0.4631 | 10.13669 |
October | 502.00000 | 24.30762 | 19.27814 | 0.27345 | 6.90208 |
November | 489.00000 | 24.12029 | 20.24323 | 0.20288 | 6.12175 |
December | 497.00000 | 23.60362 | 14.59105 | 0.01025 | 5.88558 |
Annual Sum or Average | 5943.00000 | 24.14283 | 23.40993 | -0.0999 | 7.51782 |
Minimum of Months | 454.00000 | 23.60362 | 14.59105 | -0.5230 | 5.72266 |
Maximum of Months | 514.00000 | 24.45462 | 34.47205 | 0.27345 | 11.33510 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.51005 | 21.87196 | -0.2016 | 7.45002 |
February | 454.00000 | 22.51983 | 19.85160 | -0.2155 | 7.86446 |
March | 514.00000 | 22.99730 | 19.40606 | -0.0864 | 6.72592 |
April | 485.00000 | 23.15141 | 23.64220 | -0.0219 | 6.37797 |
May | 508.00000 | 24.07965 | 25.76578 | -0.6509 | 14.58293 |
June | 496.00000 | 24.27481 | 33.51145 | -0.4653 | 9.85210 |
July | 497.00000 | 24.33406 | 35.34092 | -0.4328 | 9.25759 |
August | 514.00000 | 24.29230 | 34.05825 | -0.4578 | 9.73197 |
September | 485.00000 | 24.25525 | 25.30171 | -0.5522 | 11.98312 |
October | 502.00000 | 23.61847 | 20.83743 | 0.09104 | 6.28350 |
November | 489.00000 | 23.03400 | 22.65920 | -0.0606 | 6.11557 |
December | 497.00000 | 22.14488 | 16.34096 | -0.3311 | 9.32173 |
Annual Sum or Average | 5943.00000 | 23.44204 | 24.92817 | -0.2831 | 8.80841 |
Minimum of Months | 454.00000 | 22.14488 | 16.34096 | -0.6509 | 6.11557 |
Maximum of Months | 514.00000 | 24.33406 | 35.34092 | 0.09104 | 14.58293 |
Report: OccupantComfortDataSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.59941 | 22.54029 | -0.4358 | 11.58028 |
February | 454.00000 | 21.72022 | 20.57439 | -0.4220 | 11.56090 |
March | 514.00000 | 22.34867 | 20.00400 | -0.2511 | 9.28798 |
April | 485.00000 | 22.51884 | 24.40402 | -0.1789 | 8.48396 |
May | 508.00000 | 23.82581 | 25.93727 | -0.7403 | 17.80817 |
June | 496.00000 | 24.25248 | 33.26582 | -0.4663 | 9.92519 |
July | 497.00000 | 24.32563 | 35.15541 | -0.4303 | 9.29479 |
August | 514.00000 | 24.24946 | 33.90812 | -0.4703 | 9.96197 |
September | 485.00000 | 24.09516 | 25.23357 | -0.6159 | 13.98627 |
October | 502.00000 | 22.93820 | 21.64231 | -0.0869 | 7.29420 |
November | 489.00000 | 22.12430 | 23.95433 | -0.2908 | 8.62837 |
December | 497.00000 | 21.21077 | 16.99088 | -0.5734 | 14.62671 |
Annual Sum or Average | 5943.00000 | 22.94484 | 25.34273 | -0.4137 | 11.03717 |
Minimum of Months | 454.00000 | 21.21077 | 16.99088 | -0.7403 | 7.29420 |
Maximum of Months | 514.00000 | 24.32563 | 35.15541 | -0.0869 | 17.80817 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.46512 | 24.70995 | -0.7379 | 19.44073 |
February | 454.00000 | 20.59121 | 22.29697 | -0.7242 | 18.91477 |
March | 514.00000 | 21.39836 | 21.54633 | -0.4937 | 14.05134 |
April | 485.00000 | 21.54717 | 25.74196 | -0.4060 | 13.32317 |
May | 508.00000 | 23.46911 | 27.26549 | -0.8371 | 22.48830 |
June | 496.00000 | 24.27735 | 33.34964 | -0.4065 | 9.38714 |
July | 497.00000 | 24.38253 | 35.43216 | -0.3611 | 8.94004 |
August | 514.00000 | 24.16649 | 34.88983 | -0.4643 | 10.44188 |
September | 485.00000 | 23.80394 | 26.36348 | -0.6998 | 18.18253 |
October | 502.00000 | 21.90795 | 23.96643 | -0.3397 | 10.99644 |
November | 489.00000 | 20.98240 | 25.96934 | -0.5880 | 14.73542 |
December | 497.00000 | 20.19945 | 17.92506 | -0.8642 | 23.55041 |
Annual Sum or Average | 5943.00000 | 22.28114 | 26.66120 | -0.5758 | 15.34074 |
Minimum of Months | 454.00000 | 20.19945 | 17.92506 | -0.8642 | 8.94004 |
Maximum of Months | 514.00000 | 24.38253 | 35.43216 | -0.3397 | 23.55041 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.12385 | 24.65538 | -0.5556 | 15.29310 |
February | 454.00000 | 21.38901 | 21.97601 | -0.5010 | 15.59595 |
March | 514.00000 | 22.09917 | 20.62155 | -0.2862 | 12.35801 |
April | 485.00000 | 22.10075 | 24.70847 | -0.2334 | 12.53895 |
May | 508.00000 | 23.83791 | 26.17535 | -0.6408 | 16.68389 |
June | 496.00000 | 24.40672 | 32.71652 | -0.2467 | 7.89291 |
July | 497.00000 | 24.55383 | 34.88601 | -0.1984 | 8.10043 |
August | 514.00000 | 24.31927 | 34.01613 | -0.2900 | 8.61320 |
September | 485.00000 | 24.12703 | 25.41131 | -0.4961 | 13.48249 |
October | 502.00000 | 22.55373 | 22.76593 | -0.1582 | 10.93156 |
November | 489.00000 | 21.61787 | 25.53442 | -0.4135 | 12.15094 |
December | 497.00000 | 20.69811 | 18.38559 | -0.7193 | 20.02150 |
Annual Sum or Average | 5943.00000 | 22.74828 | 26.02411 | -0.3941 | 12.78036 |
Minimum of Months | 454.00000 | 20.69811 | 18.38559 | -0.7193 | 7.89291 |
Maximum of Months | 514.00000 | 24.55383 | 34.88601 | -0.1582 | 20.02150 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.22995 | 21.06432 | -0.2292 | 12.92008 |
February | 454.00000 | 22.11301 | 19.23735 | -0.2707 | 14.49744 |
March | 514.00000 | 22.27531 | 19.31954 | -0.2183 | 12.63725 |
April | 485.00000 | 21.96018 | 24.28781 | -0.2719 | 13.00193 |
May | 508.00000 | 23.58110 | 26.61737 | -0.7640 | 20.90199 |
June | 496.00000 | 24.24752 | 33.29015 | -0.3901 | 9.71548 |
July | 497.00000 | 24.39080 | 35.27837 | -0.3240 | 9.11702 |
August | 514.00000 | 24.25487 | 34.28382 | -0.3518 | 9.41992 |
September | 485.00000 | 24.09876 | 25.09633 | -0.4800 | 14.20025 |
October | 502.00000 | 22.79793 | 21.22707 | -0.0439 | 12.22285 |
November | 489.00000 | 22.57907 | 22.23909 | -0.1221 | 11.81416 |
December | 497.00000 | 21.74331 | 15.69639 | -0.4085 | 16.25069 |
Annual Sum or Average | 5943.00000 | 23.03116 | 24.85451 | -0.3236 | 13.04997 |
Minimum of Months | 454.00000 | 21.74331 | 15.69639 | -0.7640 | 9.11702 |
Maximum of Months | 514.00000 | 24.39080 | 35.27837 | -0.0439 | 20.90199 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.09900 | 24.14067 | -0.5626 | 16.44256 |
February | 454.00000 | 21.25013 | 21.68661 | -0.5377 | 16.57946 |
March | 514.00000 | 21.84631 | 21.11927 | -0.3497 | 13.35072 |
April | 485.00000 | 21.84227 | 25.42397 | -0.3021 | 13.33378 |
May | 508.00000 | 23.63368 | 27.03725 | -0.7235 | 20.32399 |
June | 496.00000 | 24.30973 | 33.32699 | -0.3114 | 9.32917 |
July | 497.00000 | 24.41376 | 35.42292 | -0.2901 | 8.89373 |
August | 514.00000 | 24.25476 | 34.71212 | -0.3541 | 9.57070 |
September | 485.00000 | 23.97610 | 26.04076 | -0.5687 | 16.16562 |
October | 502.00000 | 22.30424 | 23.33791 | -0.2074 | 11.59190 |
November | 489.00000 | 21.57183 | 25.31933 | -0.4232 | 13.00981 |
December | 497.00000 | 20.69549 | 17.99479 | -0.7239 | 20.78377 |
Annual Sum or Average | 5943.00000 | 22.61237 | 26.33898 | -0.4455 | 14.09264 |
Minimum of Months | 454.00000 | 20.69549 | 17.99479 | -0.7239 | 8.89373 |
Maximum of Months | 514.00000 | 24.41376 | 35.42292 | -0.2074 | 20.78377 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.66805 | 25.15218 | -0.6739 | 16.18039 |
February | 454.00000 | 20.67008 | 22.52684 | -0.6982 | 16.87521 |
March | 514.00000 | 21.28087 | 22.24335 | -0.5219 | 12.78044 |
April | 485.00000 | 21.57740 | 26.71738 | -0.4023 | 10.45749 |
May | 508.00000 | 23.40628 | 28.46196 | -0.8976 | 23.78100 |
June | 496.00000 | 24.20699 | 33.75597 | -0.4789 | 10.11579 |
July | 497.00000 | 24.30716 | 35.61704 | -0.4313 | 9.36739 |
August | 514.00000 | 24.18821 | 34.82552 | -0.4862 | 10.29824 |
September | 485.00000 | 24.03855 | 26.27571 | -0.6230 | 14.46958 |
October | 502.00000 | 22.57675 | 23.79579 | -0.1584 | 7.47555 |
November | 489.00000 | 21.51642 | 25.72984 | -0.4272 | 10.19656 |
December | 497.00000 | 20.59712 | 18.38249 | -0.7282 | 18.01206 |
Annual Sum or Average | 5943.00000 | 22.43378 | 26.99906 | -0.5433 | 13.32333 |
Minimum of Months | 454.00000 | 20.59712 | 18.38249 | -0.8976 | 7.47555 |
Maximum of Months | 514.00000 | 24.30716 | 35.61704 | -0.1584 | 23.78100 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.50331 | 25.04704 | -0.4471 | 11.54569 |
February | 454.00000 | 21.64974 | 22.11694 | -0.4305 | 12.82114 |
March | 514.00000 | 22.27967 | 21.06938 | -0.2449 | 10.14261 |
April | 485.00000 | 22.47768 | 25.13596 | -0.1525 | 8.98717 |
May | 508.00000 | 23.93961 | 26.80776 | -0.6443 | 15.71474 |
June | 496.00000 | 24.43013 | 32.76909 | -0.2812 | 7.64224 |
July | 497.00000 | 24.57358 | 34.75748 | -0.2323 | 7.59764 |
August | 514.00000 | 24.41142 | 33.66332 | -0.2794 | 7.77340 |
September | 485.00000 | 24.36774 | 25.14960 | -0.4056 | 10.19973 |
October | 502.00000 | 23.27986 | 22.33102 | 0.04143 | 8.16306 |
November | 489.00000 | 22.37243 | 24.88537 | -0.2035 | 8.25995 |
December | 497.00000 | 21.30164 | 18.71303 | -0.5384 | 14.02219 |
Annual Sum or Average | 5943.00000 | 23.06043 | 26.07464 | -0.3178 | 10.22831 |
Minimum of Months | 454.00000 | 21.30164 | 18.71303 | -0.6443 | 7.59764 |
Maximum of Months | 514.00000 | 24.57358 | 34.75748 | 0.04143 | 15.71474 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.48011 | 19.95001 | -0.1190 | 10.15707 |
February | 454.00000 | 22.11021 | 18.07230 | -0.2293 | 12.58968 |
March | 514.00000 | 22.16523 | 18.53584 | -0.2245 | 10.90703 |
April | 485.00000 | 21.92144 | 23.86576 | -0.2715 | 9.81919 |
May | 508.00000 | 23.27984 | 27.06990 | -0.8851 | 24.28521 |
June | 496.00000 | 24.16324 | 33.13032 | -0.4677 | 10.58138 |
July | 497.00000 | 24.32247 | 35.19651 | -0.3909 | 9.39610 |
August | 514.00000 | 24.28561 | 33.58224 | -0.3637 | 9.08525 |
September | 485.00000 | 24.29848 | 24.47472 | -0.3960 | 11.12826 |
October | 502.00000 | 23.28816 | 20.04450 | 0.11890 | 10.58229 |
November | 489.00000 | 22.94920 | 20.66419 | 0.02814 | 9.96420 |
December | 497.00000 | 21.98359 | 14.35488 | -0.2826 | 12.94384 |
Annual Sum or Average | 5943.00000 | 23.11181 | 24.13459 | -0.2916 | 11.79928 |
Minimum of Months | 454.00000 | 21.92144 | 14.35488 | -0.8851 | 9.08525 |
Maximum of Months | 514.00000 | 24.32247 | 35.19651 | 0.11890 | 24.28521 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.46568 | 24.70386 | -0.4553 | 12.14794 |
February | 454.00000 | 21.50563 | 22.02118 | -0.4657 | 13.17551 |
March | 514.00000 | 22.03501 | 21.56048 | -0.3085 | 10.78423 |
April | 485.00000 | 22.23058 | 25.92230 | -0.2212 | 9.31922 |
May | 508.00000 | 23.79709 | 27.58598 | -0.7140 | 18.21229 |
June | 496.00000 | 24.37184 | 33.29029 | -0.3342 | 8.52327 |
July | 497.00000 | 24.44875 | 35.30934 | -0.3215 | 8.26402 |
August | 514.00000 | 24.37658 | 34.25806 | -0.3373 | 8.42141 |
September | 485.00000 | 24.31852 | 25.52790 | -0.4504 | 11.31640 |
October | 502.00000 | 23.19287 | 22.66437 | 0.02382 | 8.14162 |
November | 489.00000 | 22.33822 | 24.78450 | -0.2098 | 8.38016 |
December | 497.00000 | 21.22740 | 18.44966 | -0.5554 | 14.75296 |
Annual Sum or Average | 5943.00000 | 22.95403 | 26.38130 | -0.3622 | 10.94796 |
Minimum of Months | 454.00000 | 21.22740 | 18.44966 | -0.7140 | 8.14162 |
Maximum of Months | 514.00000 | 24.44875 | 35.30934 | 0.02382 | 18.21229 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 20.93973 | 24.41528 | -0.5885 | 14.57564 |
February | 454.00000 | 20.95462 | 21.95884 | -0.6011 | 15.17660 |
March | 514.00000 | 21.74848 | 21.28931 | -0.3840 | 11.24891 |
April | 485.00000 | 22.03630 | 25.19834 | -0.2758 | 9.71039 |
May | 508.00000 | 23.74226 | 26.91141 | -0.7418 | 18.34582 |
June | 496.00000 | 24.32530 | 33.44367 | -0.3985 | 8.92741 |
July | 497.00000 | 24.42562 | 35.41289 | -0.3547 | 8.45982 |
August | 514.00000 | 24.24276 | 34.76846 | -0.4435 | 9.65612 |
September | 485.00000 | 24.01583 | 26.22785 | -0.6233 | 14.93554 |
October | 502.00000 | 22.46994 | 23.44431 | -0.1845 | 8.23104 |
November | 489.00000 | 21.50061 | 25.36942 | -0.4315 | 10.70751 |
December | 497.00000 | 20.57520 | 17.90876 | -0.7292 | 18.63819 |
Annual Sum or Average | 5943.00000 | 22.59557 | 26.40346 | -0.4790 | 12.36563 |
Minimum of Months | 454.00000 | 20.57520 | 17.90876 | -0.7418 | 8.23104 |
Maximum of Months | 514.00000 | 24.42562 | 35.41289 | -0.1845 | 18.63819 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 427.00000 | 21.50616 | 24.01108 | -0.4369 | 12.00107 |
February | 385.00000 | 21.62694 | 21.42074 | -0.4147 | 13.54908 |
March | 433.00000 | 22.27951 | 20.19927 | -0.2237 | 10.87501 |
April | 410.00000 | 22.40420 | 24.26310 | -0.1515 | 9.94401 |
May | 430.00000 | 24.04533 | 26.04733 | -0.5798 | 14.56864 |
June | 418.00000 | 24.52500 | 32.57918 | -0.2397 | 7.85879 |
July | 422.00000 | 24.69347 | 34.52684 | -0.1855 | 8.02714 |
August | 433.00000 | 24.44978 | 33.89483 | -0.2804 | 8.42509 |
September | 410.00000 | 24.30923 | 25.27640 | -0.4511 | 12.09383 |
October | 427.00000 | 22.91881 | 22.20568 | -0.0532 | 9.36323 |
November | 417.00000 | 22.05189 | 24.71658 | -0.2846 | 9.62738 |
December | 422.00000 | 21.01570 | 17.93687 | -0.6085 | 16.50918 |
Annual Sum or Average | 5034.00000 | 22.99523 | 25.62186 | -0.3253 | 11.05480 |
Minimum of Months | 385.00000 | 21.01570 | 17.93687 | -0.6085 | 7.85879 |
Maximum of Months | 433.00000 | 24.69347 | 34.52684 | -0.0532 | 16.50918 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 22.71064 | 20.62769 | -0.0827 | 10.50683 |
February | 454.00000 | 22.51038 | 18.67898 | -0.1459 | 12.30222 |
March | 514.00000 | 22.60542 | 18.95258 | -0.1158 | 10.63808 |
April | 485.00000 | 22.45155 | 23.66208 | -0.1434 | 9.57821 |
May | 508.00000 | 23.84157 | 26.28681 | -0.6734 | 16.92724 |
June | 496.00000 | 24.31747 | 33.33517 | -0.3769 | 9.00197 |
July | 497.00000 | 24.44958 | 35.21067 | -0.3144 | 8.45344 |
August | 514.00000 | 24.33867 | 34.13678 | -0.3312 | 8.59131 |
September | 485.00000 | 24.27344 | 25.04780 | -0.4166 | 11.69803 |
October | 502.00000 | 23.24606 | 20.83906 | 0.08622 | 10.50827 |
November | 489.00000 | 23.05121 | 21.56490 | 0.02095 | 10.13487 |
December | 497.00000 | 22.22246 | 15.30708 | -0.2595 | 12.89711 |
Annual Sum or Average | 5943.00000 | 23.34206 | 24.52453 | -0.2305 | 10.93200 |
Minimum of Months | 454.00000 | 22.22246 | 15.30708 | -0.6734 | 8.45344 |
Maximum of Months | 514.00000 | 24.44958 | 35.21067 | 0.08622 | 16.92724 |
Report: OccupantComfortDataSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] | PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] | PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] | ZONE THERMAL COMFORT FANGER MODEL PMV {FOR HOURS SHOWN} [] | ZONE THERMAL COMFORT FANGER MODEL PPD {FOR HOURS SHOWN} [%] | |
January | 502.00000 | 21.58534 | 23.75724 | -0.4131 | 12.31275 |
February | 454.00000 | 21.63008 | 21.27746 | -0.4136 | 13.44046 |
March | 514.00000 | 22.19998 | 20.80167 | -0.2413 | 10.92476 |
April | 485.00000 | 22.34301 | 24.81642 | -0.1714 | 9.83362 |
May | 508.00000 | 23.89799 | 26.64538 | -0.6320 | 16.30981 |
June | 496.00000 | 24.37693 | 33.37030 | -0.2992 | 8.58833 |
July | 497.00000 | 24.47193 | 35.37118 | -0.2803 | 8.22148 |
August | 514.00000 | 24.33881 | 34.56251 | -0.3327 | 8.72341 |
September | 485.00000 | 24.17692 | 25.89654 | -0.4969 | 13.17122 |
October | 502.00000 | 22.83306 | 22.83530 | -0.0606 | 9.17894 |
November | 489.00000 | 22.09239 | 24.64586 | -0.2687 | 9.70209 |
December | 497.00000 | 21.10043 | 17.86713 | -0.5857 | 16.34802 |
Annual Sum or Average | 5943.00000 | 22.93202 | 26.03082 | -0.3493 | 11.38278 |
Minimum of Months | 454.00000 | 21.10043 | 17.86713 | -0.6320 | 8.22148 |
Maximum of Months | 514.00000 | 24.47193 | 35.37118 | -0.0606 | 16.34802 |
Report: DXReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.319051E+10 | 0.817539E+09 | 72.99 | 0.317331E+10 | 17201151.40 | 0.00 | 0.87 | 20-JAN-14:00 | 0.00 | 01-JAN-00:10 | 28204.15 | 20-JAN-14:00 | 28204.15 | 20-JAN-14:00 | 854.61 | 27-JAN-17:06 | 6690.59 | 20-JAN-14:00 | 0.00 |
February | 0.147274E+10 | 0.407289E+09 | 74.74 | 0.144797E+10 | 24775983.78 | 0.00 | 0.47 | 24-FEB-13:06 | 0.00 | 01-FEB-00:10 | 13725.43 | 24-FEB-13:06 | 13725.43 | 24-FEB-13:06 | 767.75 | 23-FEB-12:02 | 3626.64 | 24-FEB-13:06 | 0.00 |
March | 0.375964E+10 | 0.956791E+09 | 104.12 | 0.375646E+10 | 3174637.15 | 0.00 | 1.00 | 13-MAR-13:40 | 0.00 | 01-MAR-00:10 | 39743.59 | 14-MAR-13:00 | 39743.59 | 14-MAR-13:00 | 618.66 | 30-MAR-17:02 | 9119.57 | 14-MAR-13:00 | 0.00 |
April | 0.388969E+10 | 0.103693E+10 | 131.39 | 0.380335E+10 | 86338486.85 | 0.00 | 0.78 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 24644.08 | 20-APR-13:00 | 24644.08 | 20-APR-13:00 | 2999.18 | 28-APR-14:00 | 5996.78 | 20-APR-13:00 | 0.00 |
May | 0.151114E+11 | 0.380641E+10 | 253.28 | 0.147506E+11 | 0.360821E+09 | 0.00 | 1.00 | 04-MAY-15:10 | 0.00 | 01-MAY-00:10 | 49370.51 | 17-MAY-13:00 | 49370.51 | 17-MAY-13:00 | 3342.61 | 30-MAY-17:10 | 12859.64 | 17-MAY-13:00 | 0.00 |
June | 0.538033E+11 | 0.142491E+11 | 434.48 | 0.512286E+11 | 0.257472E+10 | 0.00 | 1.00 | 01-JUN-10:20 | 0.00 | 01-JUN-00:10 | 78232.13 | 26-JUN-15:20 | 78232.13 | 26-JUN-15:20 | 18503.02 | 21-JUN-06:03 | 27692.90 | 26-JUN-15:10 | 0.00 |
July | 0.546444E+11 | 0.142514E+11 | 439.08 | 0.503393E+11 | 0.430510E+10 | 0.00 | 1.00 | 01-JUL-06:03 | 0.00 | 01-JUL-00:10 | 74143.50 | 17-JUL-12:20 | 74143.50 | 17-JUL-12:20 | 32847.17 | 31-JUL-15:50 | 23718.90 | 17-JUL-12:20 | 0.00 |
August | 0.541523E+11 | 0.140587E+11 | 432.37 | 0.513808E+11 | 0.277151E+10 | 0.00 | 1.00 | 01-AUG-12:05 | 0.00 | 01-AUG-00:10 | 72652.20 | 16-AUG-16:00 | 72652.20 | 16-AUG-16:00 | 28611.27 | 04-AUG-06:03 | 23976.01 | 16-AUG-16:00 | 0.00 |
September | 0.378275E+11 | 0.951133E+10 | 369.94 | 0.372261E+11 | 0.601360E+09 | 0.00 | 1.00 | 01-SEP-10:00 | 0.00 | 01-SEP-00:10 | 65704.03 | 12-SEP-16:00 | 65704.03 | 12-SEP-16:00 | 9891.91 | 01-SEP-14:00 | 18148.08 | 12-SEP-16:00 | 0.00 |
October | 0.110476E+11 | 0.275565E+10 | 198.23 | 0.109220E+11 | 0.125618E+09 | 0.00 | 1.00 | 10-OCT-10:00 | 0.00 | 01-OCT-00:10 | 55793.82 | 10-OCT-15:30 | 55793.82 | 10-OCT-15:30 | 1637.85 | 27-OCT-15:40 | 13229.81 | 11-OCT-14:00 | 0.00 |
November | 0.409568E+10 | 0.105657E+10 | 106.45 | 0.404137E+10 | 54310898.12 | 0.00 | 0.97 | 07-NOV-15:00 | 0.00 | 01-NOV-00:10 | 32318.63 | 07-NOV-15:00 | 32318.63 | 07-NOV-15:00 | 1195.76 | 10-NOV-12:06 | 7450.22 | 07-NOV-15:00 | 0.00 |
December | 0.188006E+10 | 0.500614E+09 | 69.08 | 0.187590E+10 | 4160491.43 | 0.00 | 0.76 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 | 23975.75 | 01-DEC-14:00 | 23975.75 | 01-DEC-14:00 | 378.15 | 04-DEC-18:02 | 5862.53 | 01-DEC-14:00 | 0.00 |
Annual Sum or Average | 0.244875E+12 | 0.634083E+11 | 2686.13 | 0.233946E+12 | 0.109291E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.147274E+10 | 0.407289E+09 | 69.08 | 0.144797E+10 | 3174637.15 | 0.00 | 0.47 | 0.00 | 13725.43 | 13725.43 | 378.15 | 3626.64 | 0.00 | ||||||
Maximum of Months | 0.546444E+11 | 0.142514E+11 | 439.08 | 0.513808E+11 | 0.430510E+10 | 0.00 | 1.00 | 0.00 | 78232.13 | 78232.13 | 32847.17 | 27692.90 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.177146E+10 | 0.464031E+09 | 51.31 | 0.175852E+10 | 12933214.27 | 0.00 | 0.80 | 24-JAN-15:05 | 0.00 | 01-JAN-00:10 | 22763.19 | 24-JAN-15:05 | 22763.19 | 24-JAN-15:05 | 1283.27 | 27-JAN-13:30 | 5509.88 | 24-JAN-15:05 | 0.00 |
February | 0.118277E+10 | 0.321720E+09 | 55.08 | 0.116078E+10 | 21990440.05 | 0.00 | 0.66 | 27-FEB-15:05 | 0.00 | 01-FEB-00:10 | 18105.01 | 27-FEB-15:05 | 18105.01 | 27-FEB-15:05 | 1045.83 | 23-FEB-13:04 | 4552.66 | 27-FEB-15:05 | 0.00 |
March | 0.334064E+10 | 0.838334E+09 | 87.28 | 0.333969E+10 | 953930.80 | 0.00 | 1.00 | 13-MAR-13:30 | 0.00 | 01-MAR-00:10 | 37904.88 | 13-MAR-16:00 | 37904.88 | 13-MAR-16:00 | 166.35 | 31-MAR-17:50 | 8652.72 | 13-MAR-16:00 | 0.00 |
April | 0.261166E+10 | 0.690023E+09 | 90.65 | 0.257119E+10 | 40472866.30 | 0.00 | 0.85 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 24591.08 | 20-APR-13:00 | 24591.08 | 20-APR-13:00 | 2727.05 | 28-APR-14:00 | 5866.22 | 20-APR-13:00 | 0.00 |
May | 0.131475E+11 | 0.329177E+10 | 236.36 | 0.127855E+11 | 0.362081E+09 | 0.00 | 1.00 | 04-MAY-14:05 | 0.00 | 01-MAY-00:10 | 48398.92 | 16-MAY-14:05 | 48398.92 | 16-MAY-14:05 | 2904.63 | 30-MAY-17:10 | 12231.90 | 17-MAY-14:05 | 0.00 |
June | 0.492687E+11 | 0.130557E+11 | 436.31 | 0.470208E+11 | 0.224794E+10 | 0.00 | 1.00 | 01-JUN-10:05 | 0.00 | 01-JUN-00:10 | 74663.43 | 26-JUN-15:20 | 74663.43 | 26-JUN-15:20 | 16072.32 | 22-JUN-13:20 | 26536.78 | 26-JUN-15:00 | 0.00 |
July | 0.499775E+11 | 0.130583E+11 | 443.45 | 0.462060E+11 | 0.377147E+10 | 0.00 | 1.00 | 01-JUL-06:03 | 0.00 | 01-JUL-00:10 | 71146.56 | 17-JUL-12:02 | 71146.56 | 17-JUL-12:02 | 31409.73 | 31-JUL-15:40 | 22754.18 | 17-JUL-12:02 | 0.00 |
August | 0.475703E+11 | 0.123974E+11 | 432.24 | 0.452045E+11 | 0.236586E+10 | 0.00 | 1.00 | 01-AUG-12:05 | 0.00 | 01-AUG-00:10 | 68947.42 | 16-AUG-15:00 | 68947.42 | 16-AUG-15:00 | 17869.52 | 28-AUG-06:02 | 22142.16 | 16-AUG-14:05 | 0.00 |
September | 0.314155E+11 | 0.794071E+10 | 357.48 | 0.309111E+11 | 0.504407E+09 | 0.00 | 1.00 | 01-SEP-10:05 | 0.00 | 01-SEP-00:10 | 61580.24 | 12-SEP-15:40 | 61580.24 | 12-SEP-15:40 | 8322.38 | 01-SEP-14:00 | 16757.10 | 12-SEP-15:50 | 0.00 |
October | 0.726465E+10 | 0.181463E+10 | 140.77 | 0.723746E+10 | 27191002.58 | 0.00 | 1.00 | 10-OCT-10:05 | 0.00 | 01-OCT-00:10 | 50755.73 | 11-OCT-14:05 | 50755.73 | 11-OCT-14:05 | 1156.15 | 03-OCT-09:05 | 12471.41 | 11-OCT-14:05 | 0.00 |
November | 0.245749E+10 | 0.634999E+09 | 68.89 | 0.243457E+10 | 22921828.78 | 0.00 | 1.00 | 07-NOV-15:05 | 0.00 | 01-NOV-00:10 | 30218.29 | 07-NOV-15:05 | 30218.29 | 07-NOV-15:05 | 976.55 | 14-NOV-13:30 | 6901.26 | 07-NOV-15:05 | 0.00 |
December | 0.113793E+10 | 0.307816E+09 | 51.62 | 0.113429E+10 | 3637467.19 | 0.00 | 0.70 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 | 19405.92 | 01-DEC-14:00 | 19405.92 | 01-DEC-14:00 | 237.46 | 03-DEC-15:30 | 4827.39 | 01-DEC-14:00 | 0.00 |
Annual Sum or Average | 0.211146E+12 | 0.548156E+11 | 2451.45 | 0.201764E+12 | 0.938186E+10 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.113793E+10 | 0.307816E+09 | 51.31 | 0.113429E+10 | 953930.80 | 0.00 | 0.66 | 0.00 | 18105.01 | 18105.01 | 166.35 | 4552.66 | 0.00 | ||||||
Maximum of Months | 0.499775E+11 | 0.130583E+11 | 443.45 | 0.470208E+11 | 0.377147E+10 | 0.00 | 1.00 | 0.00 | 74663.43 | 74663.43 | 31409.73 | 26536.78 | 0.00 |
Report: DXReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportCOOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL ELECTRICITY ENERGY [J] | COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL LATENT COOLING ENERGY [J] | COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] | COOLING COIL RUNTIME FRACTION {Maximum} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL RUNTIME FRACTION {MINIMUM} [] | COOLING COIL RUNTIME FRACTION {TIMESTAMP} | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] | COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} | COOLING COIL LATENT COOLING RATE {Maximum} [W] | COOLING COIL LATENT COOLING RATE {TIMESTAMP} | COOLING COIL ELECTRICITY RATE {Maximum} [W] | COOLING COIL ELECTRICITY RATE {TIMESTAMP} | COOLING COIL CRANKCASE HEATER ELECTRICITY RATE [] | |
January | 0.964104E+09 | 0.261384E+09 | 39.27 | 0.947217E+09 | 16887329.85 | 0.00 | 0.65 | 20-JAN-14:10 | 0.00 | 01-JAN-00:10 | 20587.95 | 20-JAN-14:10 | 20587.95 | 20-JAN-14:10 | 1021.62 | 27-JAN-13:50 | 5196.04 | 20-JAN-14:10 | 0.00 |
February | 0.152123E+10 | 0.416048E+09 | 65.32 | 0.149390E+10 | 27332883.87 | 0.00 | 0.59 | 17-FEB-15:10 | 0.00 | 01-FEB-00:10 | 18648.27 | 17-FEB-15:10 | 18648.27 | 17-FEB-15:10 | 998.64 | 17-FEB-17:03 | 4773.02 | 17-FEB-15:10 | 0.00 |
March | 0.350335E+10 | 0.892295E+09 | 90.04 | 0.349952E+10 | 3833150.21 | 0.00 | 1.00 | 13-MAR-13:50 | 0.00 | 01-MAR-00:10 | 39532.03 | 13-MAR-15:50 | 39532.03 | 13-MAR-15:50 | 482.64 | 30-MAR-16:13 | 9026.04 | 13-MAR-15:50 | 0.00 |
April | 0.263576E+10 | 0.700256E+09 | 85.77 | 0.258250E+10 | 53265662.71 | 0.00 | 0.80 | 20-APR-13:00 | 0.00 | 01-APR-00:10 | 26740.65 | 20-APR-13:00 | 26740.65 | 20-APR-13:00 | 3066.17 | 28-APR-14:00 | 6463.17 | 20-APR-13:00 | 0.00 |
May | 0.140827E+11 | 0.355585E+10 | 237.89 | 0.135851E+11 | 0.497606E+09 | 0.00 | 1.00 | 04-MAY-14:05 | 0.00 | 01-MAY-00:10 | 57213.70 | 31-MAY-15:20 | 57213.70 | 31-MAY-15:20 | 3483.62 | 30-MAY-17:10 | 14498.45 | 31-MAY-15:20 | 0.00 |
June | 0.540045E+11 | 0.144304E+11 | 437.66 | 0.515385E+11 | 0.246596E+10 | 0.00 | 1.00 | 01-JUN-10:30 | 0.00 | 01-JUN-00:10 | 86929.22 | 26-JUN-15:10 | 86929.22 | 26-JUN-15:10 | 17353.14 | 22-JUN-13:20 | 30882.05 | 26-JUN-15:00 | 0.00 |
July | 0.541330E+11 | 0.142806E+11 | 446.13 | 0.500894E+11 | 0.404360E+10 | 0.00 | 1.00 | 01-JUL-08:50 | 0.00 | 01-JUL-00:10 | 79355.62 | 17-JUL-14:00 | 79355.62 | 17-JUL-14:00 | 32527.97 | 31-JUL-15:40 | 24898.06 | 17-JUL-13:10 | 0.00 |
August | 0.516628E+11 | 0.135955E+11 | 432.67 | 0.491358E+11 | 0.252700E+10 | 0.00 | 1.00 | 02-AUG-09:50 | 0.00 | 01-AUG-00:10 | 81720.02 | 16-AUG-15:00 | 81720.02 | 16-AUG-15:00 | 17052.26 | 21-AUG-16:00 | 26230.15 | 16-AUG-15:10 | 0.00 |
September | 0.325314E+11 | 0.831427E+10 | 358.22 | 0.318575E+11 | 0.673871E+09 | 0.00 | 1.00 | 01-SEP-10:50 | 0.00 | 01-SEP-00:10 | 69370.39 | 12-SEP-15:40 | 69370.39 | 12-SEP-15:40 | 8038.07 | 01-SEP-14:00 | 18850.07 | 12-SEP-15:40 | 0.00 |
October | 0.621158E+10 | 0.157975E+10 | 122.94 | 0.616964E+10 | 41940822.73 | 0.00 | 1.00 | 10-OCT-12:05 | 0.00 | 01-OCT-00:10 | 55867.97 | 11-OCT-15:00 | 55867.97 | 11-OCT-15:00 | 1582.59 | 09-OCT-10:12 | 13522.70 | 11-OCT-14:30 | 0.00 |
November | 0.238830E+10 | 0.631121E+09 | 70.16 | 0.234885E+10 | 39449137.70 | 0.00 | 0.87 | 07-NOV-14:40 | 0.00 | 01-NOV-00:10 | 29314.05 | 07-NOV-14:40 | 29314.05 | 07-NOV-14:40 | 940.16 | 14-NOV-15:10 | 6961.89 | 07-NOV-14:40 | 0.00 |
December | 0.100450E+10 | 0.276178E+09 | 46.46 | 0.996418E+09 | 8083828.92 | 0.00 | 0.59 | 01-DEC-14:00 | 0.00 | 01-DEC-00:10 | 18376.05 | 01-DEC-14:00 | 18376.05 | 01-DEC-14:00 | 442.53 | 29-DEC-16:10 | 4712.69 | 01-DEC-14:00 | 0.00 |
Annual Sum or Average | 0.224643E+12 | 0.589336E+11 | 2432.53 | 0.214244E+12 | 0.103988E+11 | 0.00 | 0.00 | ||||||||||||
Minimum of Months | 0.964104E+09 | 0.261384E+09 | 39.27 | 0.947217E+09 | 3833150.21 | 0.00 | 0.59 | 0.00 | 18376.05 | 18376.05 | 442.53 | 4712.69 | 0.00 | ||||||
Maximum of Months | 0.541330E+11 | 0.144304E+11 | 446.13 | 0.515385E+11 | 0.404360E+10 | 0.00 | 1.00 | 0.00 | 86929.22 | 86929.22 | 32527.97 | 30882.05 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 384.46 | 0.00 | 384.46 | 84.80 | 1759.79 | 0.00 | 0.00 | 0.00 |
February | 483.22 | 0.00 | 483.22 | 103.49 | 1789.58 | 0.00 | 0.00 | 0.00 |
March | 657.51 | 0.00 | 657.51 | 316.05 | 1356.16 | 0.00 | 0.00 | 0.00 |
April | 825.73 | 4.58 | 821.15 | 474.89 | 1149.81 | 0.00 | 0.00 | 0.00 |
May | 1128.00 | 37.29 | 1090.72 | 1034.32 | 708.91 | 0.00 | 0.00 | 0.00 |
June | 1236.93 | 137.13 | 1099.80 | 1643.18 | 401.89 | 0.00 | 0.00 | 0.00 |
July | 1169.80 | 75.72 | 1094.08 | 1571.33 | 380.99 | 0.00 | 0.00 | 0.00 |
August | 931.07 | 22.03 | 909.05 | 1196.34 | 434.03 | 0.00 | 0.00 | 0.00 |
September | 782.10 | 0.18 | 781.92 | 888.88 | 664.38 | 0.00 | 0.00 | 0.00 |
October | 560.17 | 0.00 | 560.17 | 320.36 | 1345.23 | 0.00 | 0.00 | 0.00 |
November | 425.24 | 0.00 | 425.24 | 133.36 | 1595.80 | 0.00 | 0.00 | 0.00 |
December | 359.71 | 0.00 | 359.71 | 72.35 | 1980.66 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 746.69 | 23.13 | 723.56 | 656.35 | 1127.13 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 359.71 | 0.00 | 359.71 | 72.35 | 380.99 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1236.93 | 137.13 | 1099.80 | 1643.18 | 1980.66 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 802.58 | 491.85 | 310.74 | 730.73 | 1104.19 | 0.00 | 0.00 | 0.00 |
February | 1066.14 | 673.05 | 393.09 | 1015.67 | 1145.95 | 0.00 | 0.00 | 0.00 |
March | 1286.81 | 750.58 | 536.22 | 1316.30 | 874.06 | 0.00 | 0.00 | 0.00 |
April | 1319.69 | 642.84 | 676.85 | 1322.50 | 751.27 | 0.00 | 0.00 | 0.00 |
May | 1542.70 | 644.39 | 898.31 | 1753.57 | 480.21 | 0.00 | 0.00 | 0.00 |
June | 1882.25 | 988.13 | 894.12 | 2523.24 | 270.32 | 0.00 | 0.00 | 0.00 |
July | 1711.11 | 814.79 | 896.32 | 2312.77 | 256.28 | 0.00 | 0.00 | 0.00 |
August | 1725.89 | 950.56 | 775.33 | 2320.02 | 291.49 | 0.00 | 0.00 | 0.00 |
September | 1436.03 | 780.09 | 655.94 | 1832.44 | 428.61 | 0.00 | 0.00 | 0.00 |
October | 1039.97 | 569.84 | 470.13 | 1098.51 | 881.82 | 0.00 | 0.00 | 0.00 |
November | 809.48 | 457.04 | 352.44 | 773.56 | 1030.63 | 0.00 | 0.00 | 0.00 |
December | 700.80 | 403.71 | 297.09 | 610.64 | 1253.61 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1277.76 | 680.24 | 597.52 | 1469.62 | 728.50 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 700.80 | 403.71 | 297.09 | 610.64 | 256.28 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1882.25 | 988.13 | 898.31 | 2523.24 | 1253.61 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 3684.63 | 3031.01 | 653.63 | 4244.71 | 1610.26 | 0.00 | 0.00 | 0.00 |
February | 3534.25 | 2817.72 | 716.52 | 4028.57 | 1679.82 | 0.00 | 0.00 | 0.00 |
March | 2605.72 | 1714.42 | 891.30 | 3009.09 | 1336.34 | 0.00 | 0.00 | 0.00 |
April | 1687.66 | 678.61 | 1009.04 | 1782.74 | 1187.82 | 0.00 | 0.00 | 0.00 |
May | 1546.55 | 283.47 | 1263.08 | 1772.93 | 777.12 | 0.00 | 0.00 | 0.00 |
June | 1425.87 | 260.61 | 1165.26 | 2051.49 | 439.16 | 0.00 | 0.00 | 0.00 |
July | 1484.30 | 265.80 | 1218.50 | 2139.88 | 407.81 | 0.00 | 0.00 | 0.00 |
August | 1889.81 | 790.01 | 1099.80 | 2742.44 | 458.41 | 0.00 | 0.00 | 0.00 |
September | 2431.43 | 1356.72 | 1074.70 | 3312.21 | 684.30 | 0.00 | 0.00 | 0.00 |
October | 2907.28 | 2062.78 | 844.50 | 3535.60 | 1341.84 | 0.00 | 0.00 | 0.00 |
November | 3542.11 | 2823.58 | 718.53 | 4163.55 | 1537.28 | 0.00 | 0.00 | 0.00 |
December | 3387.18 | 2741.54 | 645.64 | 3822.95 | 1799.59 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2504.77 | 1561.76 | 943.01 | 3044.92 | 1101.82 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1425.87 | 260.61 | 645.64 | 1772.93 | 407.81 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3684.63 | 3031.01 | 1263.08 | 4244.71 | 1799.59 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 853.77 | 540.99 | 312.77 | 828.45 | 1131.68 | 0.00 | 0.00 | 0.00 |
February | 1029.52 | 638.00 | 391.52 | 985.19 | 1160.36 | 0.00 | 0.00 | 0.00 |
March | 1205.51 | 665.11 | 540.40 | 1224.13 | 891.05 | 0.00 | 0.00 | 0.00 |
April | 1135.04 | 480.56 | 654.48 | 1103.72 | 770.39 | 0.00 | 0.00 | 0.00 |
May | 1387.31 | 489.08 | 898.23 | 1579.40 | 508.41 | 0.00 | 0.00 | 0.00 |
June | 1696.77 | 816.38 | 880.39 | 2305.42 | 302.70 | 0.00 | 0.00 | 0.00 |
July | 1382.46 | 506.37 | 876.09 | 1882.79 | 277.53 | 0.00 | 0.00 | 0.00 |
August | 1442.90 | 712.81 | 730.09 | 1939.68 | 308.77 | 0.00 | 0.00 | 0.00 |
September | 1279.42 | 613.57 | 665.85 | 1645.82 | 457.58 | 0.00 | 0.00 | 0.00 |
October | 1076.33 | 615.20 | 461.13 | 1174.89 | 897.55 | 0.00 | 0.00 | 0.00 |
November | 883.19 | 536.20 | 346.98 | 878.36 | 1043.86 | 0.00 | 0.00 | 0.00 |
December | 713.37 | 421.41 | 291.96 | 634.71 | 1258.52 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1174.16 | 585.60 | 588.56 | 1350.06 | 748.51 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 713.37 | 421.41 | 291.96 | 634.71 | 277.53 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1696.77 | 816.38 | 898.23 | 2305.42 | 1258.52 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 128.15 | 0.00 | 128.15 | 28.26 | 604.68 | 0.00 | 0.00 | 0.00 |
February | 161.07 | 0.00 | 161.07 | 36.66 | 608.11 | 0.00 | 0.00 | 0.00 |
March | 219.16 | 0.00 | 219.16 | 112.43 | 458.01 | 0.00 | 0.00 | 0.00 |
April | 275.23 | 1.53 | 273.70 | 165.76 | 395.49 | 0.00 | 0.00 | 0.00 |
May | 375.98 | 12.43 | 363.55 | 355.08 | 234.78 | 0.00 | 0.00 | 0.00 |
June | 412.29 | 45.71 | 366.58 | 557.44 | 131.73 | 0.00 | 0.00 | 0.00 |
July | 389.92 | 25.24 | 364.68 | 533.01 | 124.37 | 0.00 | 0.00 | 0.00 |
August | 310.34 | 7.34 | 303.00 | 403.59 | 146.37 | 0.00 | 0.00 | 0.00 |
September | 260.69 | 0.06 | 260.63 | 296.18 | 233.48 | 0.00 | 0.00 | 0.00 |
October | 186.72 | 0.00 | 186.72 | 103.21 | 481.64 | 0.00 | 0.00 | 0.00 |
November | 141.74 | 0.00 | 141.74 | 41.10 | 566.89 | 0.00 | 0.00 | 0.00 |
December | 119.90 | 0.00 | 119.90 | 22.76 | 691.41 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 248.89 | 7.71 | 241.18 | 222.33 | 388.59 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 119.90 | 0.00 | 119.90 | 22.76 | 124.37 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 412.29 | 45.71 | 366.58 | 557.44 | 691.41 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 128.15 | 0.00 | 128.15 | 28.26 | 604.72 | 0.00 | 0.00 | 0.00 |
February | 161.07 | 0.00 | 161.07 | 36.66 | 608.15 | 0.00 | 0.00 | 0.00 |
March | 219.17 | 0.00 | 219.17 | 112.44 | 458.04 | 0.00 | 0.00 | 0.00 |
April | 275.24 | 1.53 | 273.72 | 165.76 | 395.51 | 0.00 | 0.00 | 0.00 |
May | 376.00 | 12.43 | 363.57 | 355.09 | 234.80 | 0.00 | 0.00 | 0.00 |
June | 412.31 | 45.71 | 366.60 | 557.47 | 131.73 | 0.00 | 0.00 | 0.00 |
July | 389.93 | 25.24 | 364.69 | 533.03 | 124.37 | 0.00 | 0.00 | 0.00 |
August | 310.36 | 7.34 | 303.01 | 403.60 | 146.38 | 0.00 | 0.00 | 0.00 |
September | 260.70 | 0.06 | 260.64 | 296.20 | 233.50 | 0.00 | 0.00 | 0.00 |
October | 186.72 | 0.00 | 186.72 | 103.21 | 481.67 | 0.00 | 0.00 | 0.00 |
November | 141.75 | 0.00 | 141.75 | 41.10 | 566.93 | 0.00 | 0.00 | 0.00 |
December | 119.90 | 0.00 | 119.90 | 22.76 | 691.46 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 248.90 | 7.71 | 241.19 | 222.34 | 388.61 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 119.90 | 0.00 | 119.90 | 22.76 | 124.37 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 412.31 | 45.71 | 366.60 | 557.47 | 691.46 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 128.15 | 0.00 | 128.15 | 28.26 | 604.72 | 0.00 | 0.00 | 0.00 |
February | 161.07 | 0.00 | 161.07 | 36.66 | 608.15 | 0.00 | 0.00 | 0.00 |
March | 219.17 | 0.00 | 219.17 | 112.44 | 458.04 | 0.00 | 0.00 | 0.00 |
April | 275.24 | 1.53 | 273.72 | 165.76 | 395.51 | 0.00 | 0.00 | 0.00 |
May | 376.00 | 12.43 | 363.57 | 355.09 | 234.80 | 0.00 | 0.00 | 0.00 |
June | 412.31 | 45.71 | 366.60 | 557.47 | 131.73 | 0.00 | 0.00 | 0.00 |
July | 389.93 | 25.24 | 364.69 | 533.03 | 124.37 | 0.00 | 0.00 | 0.00 |
August | 310.36 | 7.34 | 303.01 | 403.60 | 146.38 | 0.00 | 0.00 | 0.00 |
September | 260.70 | 0.06 | 260.64 | 296.20 | 233.50 | 0.00 | 0.00 | 0.00 |
October | 186.72 | 0.00 | 186.72 | 103.21 | 481.67 | 0.00 | 0.00 | 0.00 |
November | 141.75 | 0.00 | 141.75 | 41.10 | 566.93 | 0.00 | 0.00 | 0.00 |
December | 119.90 | 0.00 | 119.90 | 22.76 | 691.46 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 248.90 | 7.71 | 241.19 | 222.34 | 388.61 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 119.90 | 0.00 | 119.90 | 22.76 | 124.37 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 412.31 | 45.71 | 366.60 | 557.47 | 691.46 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 772.04 | 473.13 | 298.91 | 700.26 | 1114.05 | 0.00 | 0.00 | 0.00 |
February | 1025.58 | 647.44 | 378.14 | 982.15 | 1144.33 | 0.00 | 0.00 | 0.00 |
March | 1237.84 | 722.02 | 515.82 | 1277.96 | 875.71 | 0.00 | 0.00 | 0.00 |
April | 1269.47 | 618.38 | 651.09 | 1282.59 | 769.51 | 0.00 | 0.00 | 0.00 |
May | 1484.00 | 619.87 | 864.13 | 1702.44 | 473.04 | 0.00 | 0.00 | 0.00 |
June | 1810.63 | 950.53 | 860.10 | 2443.41 | 266.99 | 0.00 | 0.00 | 0.00 |
July | 1646.00 | 783.78 | 862.22 | 2240.03 | 253.04 | 0.00 | 0.00 | 0.00 |
August | 1660.22 | 914.39 | 745.83 | 2240.54 | 297.67 | 0.00 | 0.00 | 0.00 |
September | 1381.39 | 750.41 | 630.98 | 1763.02 | 447.30 | 0.00 | 0.00 | 0.00 |
October | 1000.40 | 548.16 | 452.24 | 1051.57 | 928.99 | 0.00 | 0.00 | 0.00 |
November | 778.68 | 439.65 | 339.03 | 733.98 | 1074.44 | 0.00 | 0.00 | 0.00 |
December | 674.13 | 388.35 | 285.78 | 581.00 | 1279.16 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1229.14 | 654.35 | 574.79 | 1418.62 | 741.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 674.13 | 388.35 | 285.78 | 581.00 | 253.04 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1810.63 | 950.53 | 864.13 | 2443.41 | 1279.16 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 30.53 | 18.71 | 11.82 | 27.69 | 44.05 | 0.00 | 0.00 | 0.00 |
February | 40.55 | 25.60 | 14.95 | 38.83 | 45.25 | 0.00 | 0.00 | 0.00 |
March | 48.94 | 28.55 | 20.40 | 50.53 | 34.62 | 0.00 | 0.00 | 0.00 |
April | 50.19 | 24.45 | 25.74 | 50.71 | 30.43 | 0.00 | 0.00 | 0.00 |
May | 58.68 | 24.51 | 34.17 | 67.31 | 18.70 | 0.00 | 0.00 | 0.00 |
June | 71.59 | 37.58 | 34.01 | 96.61 | 10.56 | 0.00 | 0.00 | 0.00 |
July | 65.08 | 30.99 | 34.09 | 88.57 | 10.01 | 0.00 | 0.00 | 0.00 |
August | 65.64 | 36.15 | 29.49 | 88.59 | 11.77 | 0.00 | 0.00 | 0.00 |
September | 54.62 | 29.67 | 24.95 | 69.71 | 17.69 | 0.00 | 0.00 | 0.00 |
October | 39.55 | 21.67 | 17.88 | 41.58 | 36.73 | 0.00 | 0.00 | 0.00 |
November | 30.79 | 17.38 | 13.41 | 29.02 | 42.48 | 0.00 | 0.00 | 0.00 |
December | 26.65 | 15.35 | 11.30 | 22.97 | 50.58 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 48.60 | 25.87 | 22.73 | 56.09 | 29.32 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 26.65 | 15.35 | 11.30 | 22.97 | 10.01 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 71.59 | 37.58 | 34.17 | 96.61 | 50.58 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1228.19 | 1010.32 | 217.87 | 1416.60 | 584.12 | 0.00 | 0.00 | 0.00 |
February | 1178.06 | 939.22 | 238.84 | 1351.87 | 597.88 | 0.00 | 0.00 | 0.00 |
March | 868.56 | 571.46 | 297.10 | 1013.41 | 468.36 | 0.00 | 0.00 | 0.00 |
April | 562.54 | 226.20 | 336.34 | 603.94 | 417.54 | 0.00 | 0.00 | 0.00 |
May | 515.51 | 94.49 | 421.02 | 604.13 | 258.74 | 0.00 | 0.00 | 0.00 |
June | 475.29 | 86.87 | 388.42 | 693.93 | 145.61 | 0.00 | 0.00 | 0.00 |
July | 494.76 | 88.60 | 406.16 | 722.71 | 135.47 | 0.00 | 0.00 | 0.00 |
August | 629.93 | 263.33 | 366.60 | 920.17 | 160.42 | 0.00 | 0.00 | 0.00 |
September | 810.46 | 452.23 | 358.23 | 1106.47 | 249.79 | 0.00 | 0.00 | 0.00 |
October | 969.08 | 687.58 | 281.50 | 1178.75 | 495.39 | 0.00 | 0.00 | 0.00 |
November | 1180.68 | 941.17 | 239.51 | 1389.12 | 566.19 | 0.00 | 0.00 | 0.00 |
December | 1129.04 | 913.83 | 215.21 | 1277.03 | 651.43 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 834.91 | 520.58 | 314.33 | 1021.30 | 393.11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 475.29 | 86.87 | 215.21 | 603.94 | 135.47 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1228.19 | 1010.32 | 421.02 | 1416.60 | 651.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1228.19 | 1010.32 | 217.87 | 1416.60 | 584.12 | 0.00 | 0.00 | 0.00 |
February | 1178.06 | 939.22 | 238.84 | 1351.87 | 597.88 | 0.00 | 0.00 | 0.00 |
March | 868.56 | 571.46 | 297.10 | 1013.41 | 468.36 | 0.00 | 0.00 | 0.00 |
April | 562.54 | 226.20 | 336.34 | 603.94 | 417.54 | 0.00 | 0.00 | 0.00 |
May | 515.51 | 94.49 | 421.02 | 604.13 | 258.74 | 0.00 | 0.00 | 0.00 |
June | 475.29 | 86.87 | 388.42 | 693.93 | 145.61 | 0.00 | 0.00 | 0.00 |
July | 494.76 | 88.60 | 406.16 | 722.71 | 135.47 | 0.00 | 0.00 | 0.00 |
August | 629.93 | 263.33 | 366.60 | 920.17 | 160.42 | 0.00 | 0.00 | 0.00 |
September | 810.46 | 452.23 | 358.23 | 1106.47 | 249.79 | 0.00 | 0.00 | 0.00 |
October | 969.08 | 687.58 | 281.50 | 1178.75 | 495.39 | 0.00 | 0.00 | 0.00 |
November | 1180.68 | 941.17 | 239.51 | 1389.12 | 566.19 | 0.00 | 0.00 | 0.00 |
December | 1129.04 | 913.83 | 215.21 | 1277.03 | 651.43 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 834.91 | 520.58 | 314.33 | 1021.30 | 393.11 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 475.29 | 86.87 | 215.21 | 603.94 | 135.47 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1228.19 | 1010.32 | 421.02 | 1416.60 | 651.43 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 1228.11 | 1010.25 | 217.86 | 1416.51 | 584.08 | 0.00 | 0.00 | 0.00 |
February | 1177.99 | 939.16 | 238.82 | 1351.78 | 597.84 | 0.00 | 0.00 | 0.00 |
March | 868.50 | 571.42 | 297.08 | 1013.34 | 468.33 | 0.00 | 0.00 | 0.00 |
April | 562.51 | 226.19 | 336.32 | 603.91 | 417.51 | 0.00 | 0.00 | 0.00 |
May | 515.48 | 94.48 | 421.00 | 604.10 | 258.72 | 0.00 | 0.00 | 0.00 |
June | 475.26 | 86.86 | 388.39 | 693.89 | 145.60 | 0.00 | 0.00 | 0.00 |
July | 494.73 | 88.59 | 406.14 | 722.67 | 135.46 | 0.00 | 0.00 | 0.00 |
August | 629.89 | 263.32 | 366.57 | 920.11 | 160.41 | 0.00 | 0.00 | 0.00 |
September | 810.41 | 452.20 | 358.21 | 1106.40 | 249.77 | 0.00 | 0.00 | 0.00 |
October | 969.01 | 687.54 | 281.48 | 1178.68 | 495.36 | 0.00 | 0.00 | 0.00 |
November | 1180.61 | 941.11 | 239.49 | 1389.03 | 566.15 | 0.00 | 0.00 | 0.00 |
December | 1128.97 | 913.77 | 215.20 | 1276.95 | 651.39 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 834.86 | 520.54 | 314.31 | 1021.23 | 393.09 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 475.26 | 86.86 | 215.20 | 603.91 | 135.46 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1228.11 | 1010.25 | 421.00 | 1416.51 | 651.39 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 821.28 | 520.41 | 300.88 | 799.73 | 1145.39 | 0.00 | 0.00 | 0.00 |
February | 990.35 | 613.72 | 376.63 | 956.43 | 1162.78 | 0.00 | 0.00 | 0.00 |
March | 1159.64 | 639.80 | 519.84 | 1191.69 | 891.64 | 0.00 | 0.00 | 0.00 |
April | 1091.86 | 462.27 | 629.58 | 1072.73 | 786.17 | 0.00 | 0.00 | 0.00 |
May | 1334.53 | 470.47 | 864.06 | 1536.72 | 501.36 | 0.00 | 0.00 | 0.00 |
June | 1632.21 | 785.32 | 846.89 | 2233.49 | 300.68 | 0.00 | 0.00 | 0.00 |
July | 1329.86 | 487.10 | 842.76 | 1826.85 | 271.92 | 0.00 | 0.00 | 0.00 |
August | 1388.00 | 685.69 | 702.31 | 1874.73 | 313.22 | 0.00 | 0.00 | 0.00 |
September | 1230.74 | 590.22 | 640.52 | 1583.18 | 477.84 | 0.00 | 0.00 | 0.00 |
October | 1035.38 | 591.79 | 443.58 | 1122.76 | 948.16 | 0.00 | 0.00 | 0.00 |
November | 849.58 | 515.80 | 333.78 | 837.94 | 1090.79 | 0.00 | 0.00 | 0.00 |
December | 686.23 | 405.37 | 280.86 | 608.70 | 1286.60 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1129.49 | 563.32 | 566.17 | 1305.20 | 762.55 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 686.23 | 405.37 | 280.86 | 608.70 | 271.92 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1632.21 | 785.32 | 864.06 | 2233.49 | 1286.60 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 32.47 | 20.58 | 11.90 | 31.62 | 45.29 | 0.00 | 0.00 | 0.00 |
February | 39.16 | 24.27 | 14.89 | 37.82 | 45.98 | 0.00 | 0.00 | 0.00 |
March | 45.85 | 25.30 | 20.55 | 47.12 | 35.25 | 0.00 | 0.00 | 0.00 |
April | 43.17 | 18.28 | 24.89 | 42.41 | 31.08 | 0.00 | 0.00 | 0.00 |
May | 52.77 | 18.60 | 34.16 | 60.76 | 19.82 | 0.00 | 0.00 | 0.00 |
June | 64.54 | 31.05 | 33.49 | 88.31 | 11.89 | 0.00 | 0.00 | 0.00 |
July | 52.58 | 19.26 | 33.32 | 72.23 | 10.75 | 0.00 | 0.00 | 0.00 |
August | 54.88 | 27.11 | 27.77 | 74.13 | 12.38 | 0.00 | 0.00 | 0.00 |
September | 48.66 | 23.34 | 25.33 | 62.60 | 18.89 | 0.00 | 0.00 | 0.00 |
October | 40.94 | 23.40 | 17.54 | 44.39 | 37.49 | 0.00 | 0.00 | 0.00 |
November | 33.59 | 20.39 | 13.20 | 33.13 | 43.13 | 0.00 | 0.00 | 0.00 |
December | 27.13 | 16.03 | 11.10 | 24.07 | 50.87 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 44.66 | 22.27 | 22.39 | 51.61 | 30.15 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 27.13 | 16.03 | 11.10 | 24.07 | 10.75 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 64.54 | 31.05 | 34.16 | 88.31 | 50.87 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 384.46 | 0.00 | 384.46 | 74.66 | 1863.97 | 0.00 | 0.00 | 0.00 |
February | 483.22 | 0.00 | 483.22 | 94.18 | 1879.02 | 0.00 | 0.00 | 0.00 |
March | 657.51 | 0.00 | 657.51 | 305.15 | 1431.46 | 0.00 | 0.00 | 0.00 |
April | 825.73 | 4.58 | 821.15 | 462.14 | 1232.11 | 0.00 | 0.00 | 0.00 |
May | 1128.00 | 37.29 | 1090.72 | 1020.98 | 741.10 | 0.00 | 0.00 | 0.00 |
June | 1236.93 | 137.13 | 1099.80 | 1645.23 | 412.45 | 0.00 | 0.00 | 0.00 |
July | 1169.80 | 75.72 | 1094.08 | 1574.38 | 390.60 | 0.00 | 0.00 | 0.00 |
August | 931.07 | 22.03 | 909.05 | 1197.12 | 449.38 | 0.00 | 0.00 | 0.00 |
September | 782.10 | 0.18 | 781.92 | 883.52 | 697.30 | 0.00 | 0.00 | 0.00 |
October | 560.17 | 0.00 | 560.17 | 305.39 | 1432.76 | 0.00 | 0.00 | 0.00 |
November | 425.24 | 0.00 | 425.24 | 119.73 | 1698.29 | 0.00 | 0.00 | 0.00 |
December | 359.71 | 0.00 | 359.71 | 65.20 | 2077.67 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 746.69 | 23.13 | 723.56 | 648.73 | 1188.53 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 359.71 | 0.00 | 359.71 | 65.20 | 390.60 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1236.93 | 137.13 | 1099.80 | 1645.23 | 2077.67 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 802.58 | 491.85 | 310.74 | 714.42 | 1168.59 | 0.00 | 0.00 | 0.00 |
February | 1066.14 | 673.05 | 393.09 | 1003.20 | 1201.81 | 0.00 | 0.00 | 0.00 |
March | 1286.81 | 750.58 | 536.22 | 1306.10 | 919.78 | 0.00 | 0.00 | 0.00 |
April | 1319.69 | 642.84 | 676.85 | 1311.81 | 802.69 | 0.00 | 0.00 | 0.00 |
May | 1542.70 | 644.39 | 898.31 | 1744.46 | 500.22 | 0.00 | 0.00 | 0.00 |
June | 1882.25 | 988.13 | 894.12 | 2523.15 | 277.49 | 0.00 | 0.00 | 0.00 |
July | 1711.11 | 814.79 | 896.32 | 2313.17 | 262.97 | 0.00 | 0.00 | 0.00 |
August | 1725.89 | 950.56 | 775.33 | 2319.09 | 301.54 | 0.00 | 0.00 | 0.00 |
September | 1436.03 | 780.09 | 655.94 | 1827.38 | 447.53 | 0.00 | 0.00 | 0.00 |
October | 1039.97 | 569.84 | 470.13 | 1087.90 | 934.82 | 0.00 | 0.00 | 0.00 |
November | 809.48 | 457.04 | 352.44 | 757.81 | 1094.47 | 0.00 | 0.00 | 0.00 |
December | 700.80 | 403.71 | 297.09 | 597.41 | 1315.11 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1277.76 | 680.24 | 597.52 | 1460.97 | 766.60 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 700.80 | 403.71 | 297.09 | 597.41 | 262.97 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1882.25 | 988.13 | 898.31 | 2523.15 | 1315.11 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 3684.63 | 3031.01 | 653.63 | 4222.29 | 1700.37 | 0.00 | 0.00 | 0.00 |
February | 3534.25 | 2817.72 | 716.52 | 4013.80 | 1762.66 | 0.00 | 0.00 | 0.00 |
March | 2605.72 | 1714.42 | 891.30 | 2999.32 | 1407.62 | 0.00 | 0.00 | 0.00 |
April | 1687.66 | 678.61 | 1009.04 | 1771.89 | 1269.96 | 0.00 | 0.00 | 0.00 |
May | 1546.55 | 283.47 | 1263.08 | 1765.45 | 813.56 | 0.00 | 0.00 | 0.00 |
June | 1425.87 | 260.61 | 1165.26 | 2055.97 | 453.13 | 0.00 | 0.00 | 0.00 |
July | 1484.30 | 265.80 | 1218.50 | 2144.88 | 420.00 | 0.00 | 0.00 | 0.00 |
August | 1889.81 | 790.01 | 1099.80 | 2746.11 | 475.08 | 0.00 | 0.00 | 0.00 |
September | 2431.43 | 1356.72 | 1074.70 | 3310.85 | 715.45 | 0.00 | 0.00 | 0.00 |
October | 2907.28 | 2062.78 | 844.50 | 3524.26 | 1420.87 | 0.00 | 0.00 | 0.00 |
November | 3542.11 | 2823.58 | 718.53 | 4145.35 | 1626.38 | 0.00 | 0.00 | 0.00 |
December | 3387.18 | 2741.54 | 645.64 | 3803.56 | 1889.75 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 2504.77 | 1561.76 | 943.01 | 3036.41 | 1159.58 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 1425.87 | 260.61 | 645.64 | 1765.45 | 420.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 3684.63 | 3031.01 | 1263.08 | 4222.29 | 1889.75 | 0.00 | 0.00 | 0.00 |
Report: WindowReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | SURFACE WINDOW HEAT GAIN RATE [W] | SURFACE WINDOW HEAT LOSS RATE [W] | SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] | SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] | SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS] | |
January | 853.77 | 540.99 | 312.77 | 818.61 | 1198.08 | 0.00 | 0.00 | 0.00 |
February | 1029.52 | 638.00 | 391.52 | 977.76 | 1218.89 | 0.00 | 0.00 | 0.00 |
March | 1205.51 | 665.11 | 540.40 | 1217.67 | 940.25 | 0.00 | 0.00 | 0.00 |
April | 1135.04 | 480.56 | 654.48 | 1095.60 | 824.48 | 0.00 | 0.00 | 0.00 |
May | 1387.31 | 489.08 | 898.23 | 1574.33 | 532.37 | 0.00 | 0.00 | 0.00 |
June | 1696.77 | 816.38 | 880.39 | 2309.02 | 312.19 | 0.00 | 0.00 | 0.00 |
July | 1382.46 | 506.37 | 876.09 | 1886.37 | 285.76 | 0.00 | 0.00 | 0.00 |
August | 1442.90 | 712.81 | 730.09 | 1941.73 | 319.88 | 0.00 | 0.00 | 0.00 |
September | 1279.42 | 613.57 | 665.85 | 1643.60 | 479.27 | 0.00 | 0.00 | 0.00 |
October | 1076.33 | 615.20 | 461.13 | 1165.83 | 953.51 | 0.00 | 0.00 | 0.00 |
November | 883.19 | 536.20 | 346.98 | 867.63 | 1108.98 | 0.00 | 0.00 | 0.00 |
December | 713.37 | 421.41 | 291.96 | 626.96 | 1321.08 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 1174.16 | 585.60 | 588.56 | 1345.29 | 788.92 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 713.37 | 421.41 | 291.96 | 626.96 | 285.76 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 1696.77 | 816.38 | 898.23 | 2309.02 | 1321.08 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.102974E+10 | 0.00 | 0.102974E+10 | 0.227115E+09 | 0.471342E+10 |
February | 0.116901E+10 | 0.00 | 0.116901E+10 | 0.250365E+09 | 0.432935E+10 |
March | 0.176107E+10 | 0.00 | 0.176107E+10 | 0.846498E+09 | 0.363233E+10 |
April | 0.214030E+10 | 11873484.46 | 0.212843E+10 | 0.123092E+10 | 0.298031E+10 |
May | 0.302124E+10 | 99870170.09 | 0.292137E+10 | 0.277031E+10 | 0.189873E+10 |
June | 0.320613E+10 | 0.355452E+09 | 0.285068E+10 | 0.425912E+10 | 0.104169E+10 |
July | 0.313320E+10 | 0.202818E+09 | 0.293038E+10 | 0.420865E+10 | 0.102044E+10 |
August | 0.249379E+10 | 58994652.25 | 0.243479E+10 | 0.320427E+10 | 0.116252E+10 |
September | 0.202721E+10 | 476155.58 | 0.202673E+10 | 0.230399E+10 | 0.172208E+10 |
October | 0.150037E+10 | 0.00 | 0.150037E+10 | 0.858053E+09 | 0.360306E+10 |
November | 0.110223E+10 | 0.00 | 0.110223E+10 | 0.345661E+09 | 0.413630E+10 |
December | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.193778E+09 | 0.530500E+10 |
Annual Sum or Average | 0.235478E+11 | 0.729484E+09 | 0.228183E+11 | 0.206987E+11 | 0.355452E+11 |
Minimum of Months | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.193778E+09 | 0.102044E+10 |
Maximum of Months | 0.320613E+10 | 0.355452E+09 | 0.293038E+10 | 0.425912E+10 | 0.530500E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214964E+10 | 0.131736E+10 | 0.832275E+09 | 0.195719E+10 | 0.295746E+10 |
February | 0.257921E+10 | 0.162825E+10 | 0.950966E+09 | 0.245710E+10 | 0.277228E+10 |
March | 0.344658E+10 | 0.201036E+10 | 0.143622E+10 | 0.352558E+10 | 0.234109E+10 |
April | 0.342063E+10 | 0.166625E+10 | 0.175438E+10 | 0.342793E+10 | 0.194729E+10 |
May | 0.413195E+10 | 0.172593E+10 | 0.240602E+10 | 0.469676E+10 | 0.128621E+10 |
June | 0.487878E+10 | 0.256123E+10 | 0.231755E+10 | 0.654024E+10 | 0.700664E+09 |
July | 0.458304E+10 | 0.218233E+10 | 0.240071E+10 | 0.619452E+10 | 0.686425E+09 |
August | 0.462263E+10 | 0.254598E+10 | 0.207665E+10 | 0.621395E+10 | 0.780723E+09 |
September | 0.372219E+10 | 0.202200E+10 | 0.170019E+10 | 0.474968E+10 | 0.111095E+10 |
October | 0.278546E+10 | 0.152627E+10 | 0.125919E+10 | 0.294224E+10 | 0.236186E+10 |
November | 0.209818E+10 | 0.118466E+10 | 0.913528E+09 | 0.200508E+10 | 0.267140E+10 |
December | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.163554E+10 | 0.335767E+10 |
Annual Sum or Average | 0.402953E+11 | 0.214519E+11 | 0.188434E+11 | 0.463458E+11 | 0.229740E+11 |
Minimum of Months | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.163554E+10 | 0.686425E+09 |
Maximum of Months | 0.487878E+10 | 0.256123E+10 | 0.240602E+10 | 0.654024E+10 | 0.335767E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.986892E+10 | 0.811825E+10 | 0.175067E+10 | 0.113690E+11 | 0.431293E+10 |
February | 0.855005E+10 | 0.681664E+10 | 0.173341E+10 | 0.974591E+10 | 0.406381E+10 |
March | 0.697916E+10 | 0.459189E+10 | 0.238727E+10 | 0.805954E+10 | 0.357925E+10 |
April | 0.437441E+10 | 0.175897E+10 | 0.261544E+10 | 0.462085E+10 | 0.307882E+10 |
May | 0.414228E+10 | 0.759251E+09 | 0.338303E+10 | 0.474862E+10 | 0.208145E+10 |
June | 0.369585E+10 | 0.675498E+09 | 0.302035E+10 | 0.531745E+10 | 0.113831E+10 |
July | 0.397554E+10 | 0.711908E+09 | 0.326363E+10 | 0.573146E+10 | 0.109227E+10 |
August | 0.506167E+10 | 0.211597E+10 | 0.294570E+10 | 0.734534E+10 | 0.122781E+10 |
September | 0.630226E+10 | 0.351663E+10 | 0.278563E+10 | 0.858525E+10 | 0.177372E+10 |
October | 0.778685E+10 | 0.552495E+10 | 0.226190E+10 | 0.946976E+10 | 0.359399E+10 |
November | 0.918115E+10 | 0.731871E+10 | 0.186244E+10 | 0.107919E+11 | 0.398462E+10 |
December | 0.907223E+10 | 0.734294E+10 | 0.172929E+10 | 0.102394E+11 | 0.482001E+10 |
Annual Sum or Average | 0.789904E+11 | 0.492516E+11 | 0.297388E+11 | 0.960245E+11 | 0.347470E+11 |
Minimum of Months | 0.369585E+10 | 0.675498E+09 | 0.172929E+10 | 0.462085E+10 | 0.109227E+10 |
Maximum of Months | 0.986892E+10 | 0.811825E+10 | 0.338303E+10 | 0.113690E+11 | 0.482001E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.228674E+10 | 0.144900E+10 | 0.837735E+09 | 0.221893E+10 | 0.303108E+10 |
February | 0.249063E+10 | 0.154345E+10 | 0.947175E+09 | 0.238337E+10 | 0.280713E+10 |
March | 0.322883E+10 | 0.178142E+10 | 0.144741E+10 | 0.327871E+10 | 0.238658E+10 |
April | 0.294203E+10 | 0.124560E+10 | 0.169642E+10 | 0.286085E+10 | 0.199686E+10 |
May | 0.371577E+10 | 0.130995E+10 | 0.240582E+10 | 0.423026E+10 | 0.136174E+10 |
June | 0.439802E+10 | 0.211606E+10 | 0.228196E+10 | 0.597564E+10 | 0.784591E+09 |
July | 0.370279E+10 | 0.135626E+10 | 0.234652E+10 | 0.504287E+10 | 0.743333E+09 |
August | 0.386466E+10 | 0.190920E+10 | 0.195546E+10 | 0.519523E+10 | 0.827017E+09 |
September | 0.331625E+10 | 0.159036E+10 | 0.172589E+10 | 0.426596E+10 | 0.118606E+10 |
October | 0.288284E+10 | 0.164776E+10 | 0.123508E+10 | 0.314682E+10 | 0.240399E+10 |
November | 0.228922E+10 | 0.138984E+10 | 0.899379E+09 | 0.227670E+10 | 0.270568E+10 |
December | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.170001E+10 | 0.337083E+10 |
Annual Sum or Average | 0.370285E+11 | 0.184676E+11 | 0.185609E+11 | 0.425753E+11 | 0.236049E+11 |
Minimum of Months | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.170001E+10 | 0.743333E+09 |
Maximum of Months | 0.439802E+10 | 0.211606E+10 | 0.240582E+10 | 0.597564E+10 | 0.337083E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.343232E+09 | 0.00 | 0.343232E+09 | 75694354.40 | 0.161959E+10 |
February | 0.389652E+09 | 0.00 | 0.389652E+09 | 88677191.10 | 0.147114E+10 |
March | 0.586995E+09 | 0.00 | 0.586995E+09 | 0.301145E+09 | 0.122675E+10 |
April | 0.713401E+09 | 3957640.90 | 0.709443E+09 | 0.429639E+09 | 0.102510E+10 |
May | 0.100703E+10 | 33288481.68 | 0.973745E+09 | 0.951043E+09 | 0.628844E+09 |
June | 0.106866E+10 | 0.118478E+09 | 0.950182E+09 | 0.144490E+10 | 0.341438E+09 |
July | 0.104435E+10 | 67602645.39 | 0.976748E+09 | 0.142761E+10 | 0.333100E+09 |
August | 0.831224E+09 | 19663953.70 | 0.811560E+09 | 0.108097E+10 | 0.392046E+09 |
September | 0.675704E+09 | 158711.02 | 0.675546E+09 | 0.767711E+09 | 0.605186E+09 |
October | 0.500100E+09 | 0.00 | 0.500100E+09 | 0.276429E+09 | 0.129003E+10 |
November | 0.367392E+09 | 0.00 | 0.367392E+09 | 0.106538E+09 | 0.146938E+10 |
December | 0.321136E+09 | 0.00 | 0.321136E+09 | 60959683.46 | 0.185188E+10 |
Annual Sum or Average | 0.784888E+10 | 0.243150E+09 | 0.760573E+10 | 0.701131E+10 | 0.122545E+11 |
Minimum of Months | 0.321136E+09 | 0.00 | 0.321136E+09 | 60959683.46 | 0.333100E+09 |
Maximum of Months | 0.106866E+10 | 0.118478E+09 | 0.976748E+09 | 0.144490E+10 | 0.185188E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.343246E+09 | 0.00 | 0.343246E+09 | 75695324.06 | 0.161969E+10 |
February | 0.389669E+09 | 0.00 | 0.389669E+09 | 88678965.62 | 0.147123E+10 |
March | 0.587020E+09 | 0.00 | 0.587020E+09 | 0.301154E+09 | 0.122682E+10 |
April | 0.713429E+09 | 3957747.28 | 0.709472E+09 | 0.429651E+09 | 0.102517E+10 |
May | 0.100707E+10 | 33289376.48 | 0.973784E+09 | 0.951074E+09 | 0.628882E+09 |
June | 0.106870E+10 | 0.118481E+09 | 0.950222E+09 | 0.144496E+10 | 0.341457E+09 |
July | 0.104439E+10 | 67604462.56 | 0.976787E+09 | 0.142767E+10 | 0.333118E+09 |
August | 0.831259E+09 | 19664482.27 | 0.811595E+09 | 0.108101E+10 | 0.392067E+09 |
September | 0.675733E+09 | 158715.28 | 0.675574E+09 | 0.767744E+09 | 0.605221E+09 |
October | 0.500121E+09 | 0.00 | 0.500121E+09 | 0.276439E+09 | 0.129011E+10 |
November | 0.367408E+09 | 0.00 | 0.367408E+09 | 0.106540E+09 | 0.146948E+10 |
December | 0.321149E+09 | 0.00 | 0.321149E+09 | 60961050.03 | 0.185200E+10 |
Annual Sum or Average | 0.784920E+10 | 0.243156E+09 | 0.760605E+10 | 0.701158E+10 | 0.122552E+11 |
Minimum of Months | 0.321149E+09 | 0.00 | 0.321149E+09 | 60961050.03 | 0.333118E+09 |
Maximum of Months | 0.106870E+10 | 0.118481E+09 | 0.976787E+09 | 0.144496E+10 | 0.185200E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.343246E+09 | 0.00 | 0.343246E+09 | 75695324.06 | 0.161969E+10 |
February | 0.389669E+09 | 0.00 | 0.389669E+09 | 88678965.62 | 0.147123E+10 |
March | 0.587020E+09 | 0.00 | 0.587020E+09 | 0.301154E+09 | 0.122682E+10 |
April | 0.713429E+09 | 3957747.28 | 0.709472E+09 | 0.429651E+09 | 0.102517E+10 |
May | 0.100707E+10 | 33289376.48 | 0.973784E+09 | 0.951074E+09 | 0.628882E+09 |
June | 0.106870E+10 | 0.118481E+09 | 0.950222E+09 | 0.144496E+10 | 0.341457E+09 |
July | 0.104439E+10 | 67604462.56 | 0.976787E+09 | 0.142767E+10 | 0.333118E+09 |
August | 0.831259E+09 | 19664482.27 | 0.811595E+09 | 0.108101E+10 | 0.392067E+09 |
September | 0.675733E+09 | 158715.28 | 0.675574E+09 | 0.767744E+09 | 0.605221E+09 |
October | 0.500121E+09 | 0.00 | 0.500121E+09 | 0.276439E+09 | 0.129011E+10 |
November | 0.367408E+09 | 0.00 | 0.367408E+09 | 0.106540E+09 | 0.146948E+10 |
December | 0.321149E+09 | 0.00 | 0.321149E+09 | 60961050.03 | 0.185200E+10 |
Annual Sum or Average | 0.784920E+10 | 0.243156E+09 | 0.760605E+10 | 0.701158E+10 | 0.122552E+11 |
Minimum of Months | 0.321149E+09 | 0.00 | 0.321149E+09 | 60961050.03 | 0.333118E+09 |
Maximum of Months | 0.106870E+10 | 0.118481E+09 | 0.976787E+09 | 0.144496E+10 | 0.185200E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.206784E+10 | 0.126723E+10 | 0.800611E+09 | 0.187556E+10 | 0.298387E+10 |
February | 0.248107E+10 | 0.156629E+10 | 0.914786E+09 | 0.237601E+10 | 0.276835E+10 |
March | 0.331543E+10 | 0.193386E+10 | 0.138158E+10 | 0.342288E+10 | 0.234550E+10 |
April | 0.329048E+10 | 0.160284E+10 | 0.168763E+10 | 0.332448E+10 | 0.199458E+10 |
May | 0.397473E+10 | 0.166025E+10 | 0.231448E+10 | 0.455981E+10 | 0.126699E+10 |
June | 0.469314E+10 | 0.246377E+10 | 0.222938E+10 | 0.633333E+10 | 0.692030E+09 |
July | 0.440866E+10 | 0.209929E+10 | 0.230937E+10 | 0.599971E+10 | 0.677748E+09 |
August | 0.444673E+10 | 0.244909E+10 | 0.199764E+10 | 0.600107E+10 | 0.797276E+09 |
September | 0.358056E+10 | 0.194505E+10 | 0.163550E+10 | 0.456975E+10 | 0.115940E+10 |
October | 0.267947E+10 | 0.146819E+10 | 0.121128E+10 | 0.281651E+10 | 0.248820E+10 |
November | 0.201835E+10 | 0.113957E+10 | 0.878772E+09 | 0.190249E+10 | 0.278494E+10 |
December | 0.180559E+10 | 0.104015E+10 | 0.765447E+09 | 0.155615E+10 | 0.342612E+10 |
Annual Sum or Average | 0.387621E+11 | 0.206356E+11 | 0.181265E+11 | 0.447377E+11 | 0.233850E+11 |
Minimum of Months | 0.180559E+10 | 0.104015E+10 | 0.765447E+09 | 0.155615E+10 | 0.677748E+09 |
Maximum of Months | 0.469314E+10 | 0.246377E+10 | 0.231448E+10 | 0.633333E+10 | 0.342612E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 81760686.43 | 50105254.26 | 31655432.17 | 74158137.52 | 0.117980E+09 |
February | 98099357.20 | 61929538.73 | 36169818.47 | 93945347.33 | 0.109458E+09 |
March | 0.131089E+09 | 76462961.31 | 54626324.10 | 0.135337E+09 | 92738781.09 |
April | 0.130102E+09 | 63374965.96 | 66727507.05 | 0.131447E+09 | 78863821.75 |
May | 0.157157E+09 | 65644977.66 | 91512381.12 | 0.180291E+09 | 50095697.07 |
June | 0.185563E+09 | 97415121.80 | 88147574.49 | 0.250414E+09 | 27362255.32 |
July | 0.174314E+09 | 83003846.61 | 91310418.94 | 0.237223E+09 | 26797548.39 |
August | 0.175820E+09 | 96834891.99 | 78984946.19 | 0.237277E+09 | 31523576.34 |
September | 0.141572E+09 | 76905604.65 | 64666355.52 | 0.180684E+09 | 45841466.76 |
October | 0.105944E+09 | 58050904.71 | 47892977.97 | 0.111362E+09 | 98381341.40 |
November | 79803621.74 | 45057757.81 | 34745863.93 | 75222590.66 | 0.110114E+09 |
December | 71391537.52 | 41126470.69 | 30265066.83 | 61528727.88 | 0.135466E+09 |
Annual Sum or Average | 0.153262E+10 | 0.815912E+09 | 0.716705E+09 | 0.176889E+10 | 0.924622E+09 |
Minimum of Months | 71391537.52 | 41126470.69 | 30265066.83 | 61528727.88 | 26797548.39 |
Maximum of Months | 0.185563E+09 | 97415121.80 | 91512381.12 | 0.250414E+09 | 0.135466E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.328958E+10 | 0.270603E+10 | 0.583550E+09 | 0.379422E+10 | 0.156451E+10 |
February | 0.284996E+10 | 0.227217E+10 | 0.577798E+09 | 0.327044E+10 | 0.144640E+10 |
March | 0.232635E+10 | 0.153060E+10 | 0.795748E+09 | 0.271431E+10 | 0.125445E+10 |
April | 0.145812E+10 | 0.586310E+09 | 0.871805E+09 | 0.156542E+10 | 0.108226E+10 |
May | 0.138075E+10 | 0.253078E+09 | 0.112767E+10 | 0.161811E+10 | 0.693003E+09 |
June | 0.123194E+10 | 0.225161E+09 | 0.100678E+10 | 0.179868E+10 | 0.377428E+09 |
July | 0.132517E+10 | 0.237298E+09 | 0.108787E+10 | 0.193571E+10 | 0.362840E+09 |
August | 0.168720E+10 | 0.705309E+09 | 0.981894E+09 | 0.246458E+10 | 0.429671E+09 |
September | 0.210072E+10 | 0.117218E+10 | 0.928536E+09 | 0.286796E+10 | 0.647445E+09 |
October | 0.259557E+10 | 0.184161E+10 | 0.753960E+09 | 0.315716E+10 | 0.132684E+10 |
November | 0.306033E+10 | 0.243952E+10 | 0.620807E+09 | 0.360059E+10 | 0.146755E+10 |
December | 0.302402E+10 | 0.244760E+10 | 0.576423E+09 | 0.342040E+10 | 0.174480E+10 |
Annual Sum or Average | 0.263297E+11 | 0.164169E+11 | 0.991283E+10 | 0.322076E+11 | 0.123972E+11 |
Minimum of Months | 0.123194E+10 | 0.225161E+09 | 0.576423E+09 | 0.156542E+10 | 0.362840E+09 |
Maximum of Months | 0.328958E+10 | 0.270603E+10 | 0.112767E+10 | 0.379422E+10 | 0.174480E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.328958E+10 | 0.270603E+10 | 0.583550E+09 | 0.379422E+10 | 0.156451E+10 |
February | 0.284996E+10 | 0.227217E+10 | 0.577798E+09 | 0.327044E+10 | 0.144640E+10 |
March | 0.232635E+10 | 0.153060E+10 | 0.795748E+09 | 0.271431E+10 | 0.125445E+10 |
April | 0.145812E+10 | 0.586310E+09 | 0.871805E+09 | 0.156542E+10 | 0.108226E+10 |
May | 0.138075E+10 | 0.253078E+09 | 0.112767E+10 | 0.161811E+10 | 0.693003E+09 |
June | 0.123194E+10 | 0.225161E+09 | 0.100678E+10 | 0.179868E+10 | 0.377428E+09 |
July | 0.132517E+10 | 0.237298E+09 | 0.108787E+10 | 0.193571E+10 | 0.362840E+09 |
August | 0.168720E+10 | 0.705309E+09 | 0.981894E+09 | 0.246458E+10 | 0.429671E+09 |
September | 0.210072E+10 | 0.117218E+10 | 0.928536E+09 | 0.286796E+10 | 0.647445E+09 |
October | 0.259557E+10 | 0.184161E+10 | 0.753960E+09 | 0.315716E+10 | 0.132684E+10 |
November | 0.306033E+10 | 0.243952E+10 | 0.620807E+09 | 0.360059E+10 | 0.146755E+10 |
December | 0.302402E+10 | 0.244760E+10 | 0.576423E+09 | 0.342040E+10 | 0.174480E+10 |
Annual Sum or Average | 0.263297E+11 | 0.164169E+11 | 0.991283E+10 | 0.322076E+11 | 0.123972E+11 |
Minimum of Months | 0.123194E+10 | 0.225161E+09 | 0.576423E+09 | 0.156542E+10 | 0.362840E+09 |
Maximum of Months | 0.328958E+10 | 0.270603E+10 | 0.112767E+10 | 0.379422E+10 | 0.174480E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.328937E+10 | 0.270586E+10 | 0.583513E+09 | 0.379398E+10 | 0.156441E+10 |
February | 0.284978E+10 | 0.227202E+10 | 0.577762E+09 | 0.327023E+10 | 0.144631E+10 |
March | 0.232620E+10 | 0.153050E+10 | 0.795698E+09 | 0.271414E+10 | 0.125437E+10 |
April | 0.145802E+10 | 0.586273E+09 | 0.871750E+09 | 0.156532E+10 | 0.108219E+10 |
May | 0.138066E+10 | 0.253062E+09 | 0.112760E+10 | 0.161801E+10 | 0.692959E+09 |
June | 0.123186E+10 | 0.225147E+09 | 0.100672E+10 | 0.179856E+10 | 0.377404E+09 |
July | 0.132508E+10 | 0.237283E+09 | 0.108780E+10 | 0.193559E+10 | 0.362817E+09 |
August | 0.168710E+10 | 0.705264E+09 | 0.981832E+09 | 0.246443E+10 | 0.429644E+09 |
September | 0.210059E+10 | 0.117211E+10 | 0.928477E+09 | 0.286778E+10 | 0.647404E+09 |
October | 0.259541E+10 | 0.184149E+10 | 0.753912E+09 | 0.315696E+10 | 0.132676E+10 |
November | 0.306013E+10 | 0.243937E+10 | 0.620768E+09 | 0.360037E+10 | 0.146746E+10 |
December | 0.302383E+10 | 0.244744E+10 | 0.576387E+09 | 0.342019E+10 | 0.174469E+10 |
Annual Sum or Average | 0.263280E+11 | 0.164158E+11 | 0.991221E+10 | 0.322056E+11 | 0.123964E+11 |
Minimum of Months | 0.123186E+10 | 0.225147E+09 | 0.576387E+09 | 0.156532E+10 | 0.362817E+09 |
Maximum of Months | 0.328937E+10 | 0.270586E+10 | 0.112760E+10 | 0.379398E+10 | 0.174469E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.219973E+10 | 0.139386E+10 | 0.805865E+09 | 0.214200E+10 | 0.306780E+10 |
February | 0.239586E+10 | 0.148472E+10 | 0.911142E+09 | 0.231380E+10 | 0.281299E+10 |
March | 0.310598E+10 | 0.171363E+10 | 0.139235E+10 | 0.319181E+10 | 0.238817E+10 |
April | 0.283009E+10 | 0.119821E+10 | 0.163188E+10 | 0.278051E+10 | 0.203775E+10 |
May | 0.357440E+10 | 0.126010E+10 | 0.231429E+10 | 0.411594E+10 | 0.134286E+10 |
June | 0.423068E+10 | 0.203554E+10 | 0.219515E+10 | 0.578921E+10 | 0.779363E+09 |
July | 0.356191E+10 | 0.130466E+10 | 0.225725E+10 | 0.489305E+10 | 0.728324E+09 |
August | 0.371762E+10 | 0.183655E+10 | 0.188107E+10 | 0.502129E+10 | 0.838916E+09 |
September | 0.319008E+10 | 0.152985E+10 | 0.166023E+10 | 0.410360E+10 | 0.123855E+10 |
October | 0.277316E+10 | 0.158506E+10 | 0.118810E+10 | 0.300721E+10 | 0.253956E+10 |
November | 0.220212E+10 | 0.133695E+10 | 0.865163E+09 | 0.217193E+10 | 0.282732E+10 |
December | 0.183800E+10 | 0.108575E+10 | 0.752247E+09 | 0.163035E+10 | 0.344602E+10 |
Annual Sum or Average | 0.356196E+11 | 0.177649E+11 | 0.178547E+11 | 0.411607E+11 | 0.240476E+11 |
Minimum of Months | 0.183800E+10 | 0.108575E+10 | 0.752247E+09 | 0.163035E+10 | 0.728324E+09 |
Maximum of Months | 0.423068E+10 | 0.203554E+10 | 0.231429E+10 | 0.578921E+10 | 0.344602E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 86975063.61 | 55111960.46 | 31863103.15 | 84692545.34 | 0.121298E+09 |
February | 94730006.39 | 58704353.86 | 36025652.54 | 91485049.40 | 0.111223E+09 |
March | 0.122807E+09 | 67755274.10 | 55052016.37 | 0.126201E+09 | 94426274.32 |
April | 0.111899E+09 | 47375869.14 | 64522999.00 | 0.109938E+09 | 80570697.55 |
May | 0.141328E+09 | 49823187.03 | 91504875.63 | 0.162740E+09 | 53095292.78 |
June | 0.167277E+09 | 80483061.54 | 86793885.65 | 0.228900E+09 | 30815272.95 |
July | 0.140834E+09 | 51584726.00 | 89249486.79 | 0.193466E+09 | 28797241.11 |
August | 0.146991E+09 | 72615278.85 | 74375646.53 | 0.198537E+09 | 33169956.70 |
September | 0.126132E+09 | 60488701.33 | 65643764.97 | 0.162252E+09 | 48971239.78 |
October | 0.109648E+09 | 62671682.37 | 46976140.24 | 0.118902E+09 | 0.100412E+09 |
November | 87069489.53 | 52861796.30 | 34207693.24 | 85875811.13 | 0.111790E+09 |
December | 72672600.43 | 42929506.76 | 29743093.67 | 64462382.61 | 0.136252E+09 |
Annual Sum or Average | 0.140836E+10 | 0.702405E+09 | 0.705958E+09 | 0.162745E+10 | 0.950822E+09 |
Minimum of Months | 72672600.43 | 42929506.76 | 29743093.67 | 64462382.61 | 28797241.11 |
Maximum of Months | 0.167277E+09 | 80483061.54 | 91504875.63 | 0.228900E+09 | 0.136252E+09 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.102974E+10 | 0.00 | 0.102974E+10 | 0.199962E+09 | 0.499245E+10 |
February | 0.116901E+10 | 0.00 | 0.116901E+10 | 0.227837E+09 | 0.454574E+10 |
March | 0.176107E+10 | 0.00 | 0.176107E+10 | 0.817303E+09 | 0.383402E+10 |
April | 0.214030E+10 | 11873484.46 | 0.212843E+10 | 0.119786E+10 | 0.319364E+10 |
May | 0.302124E+10 | 99870170.09 | 0.292137E+10 | 0.273459E+10 | 0.198495E+10 |
June | 0.320613E+10 | 0.355452E+09 | 0.285068E+10 | 0.426443E+10 | 0.106908E+10 |
July | 0.313320E+10 | 0.202818E+09 | 0.293038E+10 | 0.421683E+10 | 0.104618E+10 |
August | 0.249379E+10 | 58994652.25 | 0.243479E+10 | 0.320637E+10 | 0.120363E+10 |
September | 0.202721E+10 | 476155.58 | 0.202673E+10 | 0.229008E+10 | 0.180741E+10 |
October | 0.150037E+10 | 0.00 | 0.150037E+10 | 0.817967E+09 | 0.383750E+10 |
November | 0.110223E+10 | 0.00 | 0.110223E+10 | 0.310352E+09 | 0.440196E+10 |
December | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.174643E+09 | 0.556483E+10 |
Annual Sum or Average | 0.235478E+11 | 0.729484E+09 | 0.228183E+11 | 0.204582E+11 | 0.374814E+11 |
Minimum of Months | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.174643E+09 | 0.104618E+10 |
Maximum of Months | 0.320613E+10 | 0.355452E+09 | 0.293038E+10 | 0.426443E+10 | 0.556483E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_2_WALL_EAST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.214964E+10 | 0.131736E+10 | 0.832275E+09 | 0.191350E+10 | 0.312996E+10 |
February | 0.257921E+10 | 0.162825E+10 | 0.950966E+09 | 0.242694E+10 | 0.290743E+10 |
March | 0.344658E+10 | 0.201036E+10 | 0.143622E+10 | 0.349826E+10 | 0.246353E+10 |
April | 0.342063E+10 | 0.166625E+10 | 0.175438E+10 | 0.340022E+10 | 0.208057E+10 |
May | 0.413195E+10 | 0.172593E+10 | 0.240602E+10 | 0.467237E+10 | 0.133978E+10 |
June | 0.487878E+10 | 0.256123E+10 | 0.231755E+10 | 0.654001E+10 | 0.719263E+09 |
July | 0.458304E+10 | 0.218233E+10 | 0.240071E+10 | 0.619560E+10 | 0.704338E+09 |
August | 0.462263E+10 | 0.254598E+10 | 0.207665E+10 | 0.621146E+10 | 0.807651E+09 |
September | 0.372219E+10 | 0.202200E+10 | 0.170019E+10 | 0.473658E+10 | 0.116000E+10 |
October | 0.278546E+10 | 0.152627E+10 | 0.125919E+10 | 0.291384E+10 | 0.250382E+10 |
November | 0.209818E+10 | 0.118466E+10 | 0.913528E+09 | 0.196425E+10 | 0.283688E+10 |
December | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.160010E+10 | 0.352238E+10 |
Annual Sum or Average | 0.402953E+11 | 0.214519E+11 | 0.188434E+11 | 0.460731E+11 | 0.241756E+11 |
Minimum of Months | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.160010E+10 | 0.704338E+09 |
Maximum of Months | 0.487878E+10 | 0.256123E+10 | 0.240602E+10 | 0.654001E+10 | 0.352238E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.986892E+10 | 0.811825E+10 | 0.175067E+10 | 0.113090E+11 | 0.455428E+10 |
February | 0.855005E+10 | 0.681664E+10 | 0.173341E+10 | 0.971018E+10 | 0.426423E+10 |
March | 0.697916E+10 | 0.459189E+10 | 0.238727E+10 | 0.803338E+10 | 0.377016E+10 |
April | 0.437441E+10 | 0.175897E+10 | 0.261544E+10 | 0.459273E+10 | 0.329173E+10 |
May | 0.414228E+10 | 0.759251E+09 | 0.338303E+10 | 0.472858E+10 | 0.217905E+10 |
June | 0.369585E+10 | 0.675498E+09 | 0.302035E+10 | 0.532908E+10 | 0.117453E+10 |
July | 0.397554E+10 | 0.711908E+09 | 0.326363E+10 | 0.574485E+10 | 0.112494E+10 |
August | 0.506167E+10 | 0.211597E+10 | 0.294570E+10 | 0.735519E+10 | 0.127246E+10 |
September | 0.630226E+10 | 0.351663E+10 | 0.278563E+10 | 0.858173E+10 | 0.185445E+10 |
October | 0.778685E+10 | 0.552495E+10 | 0.226190E+10 | 0.943938E+10 | 0.380566E+10 |
November | 0.918115E+10 | 0.731871E+10 | 0.186244E+10 | 0.107447E+11 | 0.421559E+10 |
December | 0.907223E+10 | 0.734294E+10 | 0.172929E+10 | 0.101875E+11 | 0.506150E+10 |
Annual Sum or Average | 0.789904E+11 | 0.492516E+11 | 0.297388E+11 | 0.957563E+11 | 0.365686E+11 |
Minimum of Months | 0.369585E+10 | 0.675498E+09 | 0.172929E+10 | 0.459273E+10 | 0.112494E+10 |
Maximum of Months | 0.986892E+10 | 0.811825E+10 | 0.338303E+10 | 0.113090E+11 | 0.506150E+10 |
Report: WindowEnergyReportMonthly
For: PERIMETER_MID_ZN_4_WALL_WEST_WINDOW
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | SURFACE WINDOW HEAT GAIN ENERGY [J] | SURFACE WINDOW HEAT LOSS ENERGY [J] | |
January | 0.228674E+10 | 0.144900E+10 | 0.837735E+09 | 0.219256E+10 | 0.320894E+10 |
February | 0.249063E+10 | 0.154345E+10 | 0.947175E+09 | 0.236540E+10 | 0.294874E+10 |
March | 0.322883E+10 | 0.178142E+10 | 0.144741E+10 | 0.326140E+10 | 0.251837E+10 |
April | 0.294203E+10 | 0.124560E+10 | 0.169642E+10 | 0.283979E+10 | 0.213706E+10 |
May | 0.371577E+10 | 0.130995E+10 | 0.240582E+10 | 0.421669E+10 | 0.142590E+10 |
June | 0.439802E+10 | 0.211606E+10 | 0.228196E+10 | 0.598497E+10 | 0.809190E+09 |
July | 0.370279E+10 | 0.135626E+10 | 0.234652E+10 | 0.505245E+10 | 0.765368E+09 |
August | 0.386466E+10 | 0.190920E+10 | 0.195546E+10 | 0.520073E+10 | 0.856764E+09 |
September | 0.331625E+10 | 0.159036E+10 | 0.172589E+10 | 0.426022E+10 | 0.124228E+10 |
October | 0.288284E+10 | 0.164776E+10 | 0.123508E+10 | 0.312255E+10 | 0.255389E+10 |
November | 0.228922E+10 | 0.138984E+10 | 0.899379E+09 | 0.224890E+10 | 0.287447E+10 |
December | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.167926E+10 | 0.353839E+10 |
Annual Sum or Average | 0.370285E+11 | 0.184676E+11 | 0.185609E+11 | 0.424249E+11 | 0.248794E+11 |
Minimum of Months | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.167926E+10 | 0.765368E+09 |
Maximum of Months | 0.439802E+10 | 0.211606E+10 | 0.240582E+10 | 0.598497E+10 | 0.353839E+10 |
Report: WindowZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 84.80 | 1759.79 | 384.46 | 0.00 | 384.46 | 0.00 | 0.00 |
February | 103.49 | 1789.58 | 483.22 | 0.00 | 483.22 | 0.00 | 0.00 |
March | 316.05 | 1356.16 | 657.51 | 0.00 | 657.51 | 0.00 | 0.00 |
April | 474.89 | 1149.81 | 825.73 | 4.58 | 821.15 | 0.00 | 0.00 |
May | 1034.32 | 708.91 | 1128.00 | 37.29 | 1090.72 | 0.00 | 0.00 |
June | 1643.18 | 401.89 | 1236.93 | 137.13 | 1099.80 | 0.00 | 0.00 |
July | 1571.33 | 380.99 | 1169.80 | 75.72 | 1094.08 | 0.00 | 0.00 |
August | 1196.34 | 434.03 | 931.07 | 22.03 | 909.05 | 0.00 | 0.00 |
September | 888.88 | 664.38 | 782.10 | 0.18 | 781.92 | 0.00 | 0.00 |
October | 320.36 | 1345.23 | 560.17 | 0.00 | 560.17 | 0.00 | 0.00 |
November | 133.36 | 1595.80 | 425.24 | 0.00 | 425.24 | 0.00 | 0.00 |
December | 72.35 | 1980.66 | 359.71 | 0.00 | 359.71 | 0.00 | 0.00 |
Annual Sum or Average | 656.35 | 1127.13 | 746.69 | 23.13 | 723.56 | 0.00 | 0.00 |
Minimum of Months | 72.35 | 380.99 | 359.71 | 0.00 | 359.71 | 0.00 | 0.00 |
Maximum of Months | 1643.18 | 1980.66 | 1236.93 | 137.13 | 1099.80 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 730.73 | 1104.19 | 802.58 | 491.85 | 310.74 | 0.00 | 0.00 |
February | 1015.67 | 1145.95 | 1066.14 | 673.05 | 393.09 | 0.00 | 0.00 |
March | 1316.30 | 874.06 | 1286.81 | 750.58 | 536.22 | 0.00 | 0.00 |
April | 1322.50 | 751.27 | 1319.69 | 642.84 | 676.85 | 0.00 | 0.00 |
May | 1753.57 | 480.21 | 1542.70 | 644.39 | 898.31 | 0.00 | 0.00 |
June | 2523.24 | 270.32 | 1882.25 | 988.13 | 894.12 | 0.00 | 0.00 |
July | 2312.77 | 256.28 | 1711.11 | 814.79 | 896.32 | 0.00 | 0.00 |
August | 2320.02 | 291.49 | 1725.89 | 950.56 | 775.33 | 0.00 | 0.00 |
September | 1832.44 | 428.61 | 1436.03 | 780.09 | 655.94 | 0.00 | 0.00 |
October | 1098.51 | 881.82 | 1039.97 | 569.84 | 470.13 | 0.00 | 0.00 |
November | 773.56 | 1030.63 | 809.48 | 457.04 | 352.44 | 0.00 | 0.00 |
December | 610.64 | 1253.61 | 700.80 | 403.71 | 297.09 | 0.00 | 0.00 |
Annual Sum or Average | 1469.62 | 728.50 | 1277.76 | 680.24 | 597.52 | 0.00 | 0.00 |
Minimum of Months | 610.64 | 256.28 | 700.80 | 403.71 | 297.09 | 0.00 | 0.00 |
Maximum of Months | 2523.24 | 1253.61 | 1882.25 | 988.13 | 898.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 4244.71 | 1610.26 | 3684.63 | 3031.01 | 653.63 | 0.00 | 0.00 |
February | 4028.57 | 1679.82 | 3534.25 | 2817.72 | 716.52 | 0.00 | 0.00 |
March | 3009.09 | 1336.34 | 2605.72 | 1714.42 | 891.30 | 0.00 | 0.00 |
April | 1782.74 | 1187.82 | 1687.66 | 678.61 | 1009.04 | 0.00 | 0.00 |
May | 1772.93 | 777.12 | 1546.55 | 283.47 | 1263.08 | 0.00 | 0.00 |
June | 2051.49 | 439.16 | 1425.87 | 260.61 | 1165.26 | 0.00 | 0.00 |
July | 2139.88 | 407.81 | 1484.30 | 265.80 | 1218.50 | 0.00 | 0.00 |
August | 2742.44 | 458.41 | 1889.81 | 790.01 | 1099.80 | 0.00 | 0.00 |
September | 3312.21 | 684.30 | 2431.43 | 1356.72 | 1074.70 | 0.00 | 0.00 |
October | 3535.60 | 1341.84 | 2907.28 | 2062.78 | 844.50 | 0.00 | 0.00 |
November | 4163.55 | 1537.28 | 3542.11 | 2823.58 | 718.53 | 0.00 | 0.00 |
December | 3822.95 | 1799.59 | 3387.18 | 2741.54 | 645.64 | 0.00 | 0.00 |
Annual Sum or Average | 3044.92 | 1101.82 | 2504.77 | 1561.76 | 943.01 | 0.00 | 0.00 |
Minimum of Months | 1772.93 | 407.81 | 1425.87 | 260.61 | 645.64 | 0.00 | 0.00 |
Maximum of Months | 4244.71 | 1799.59 | 3684.63 | 3031.01 | 1263.08 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 828.45 | 1131.68 | 853.77 | 540.99 | 312.77 | 0.00 | 0.00 |
February | 985.19 | 1160.36 | 1029.52 | 638.00 | 391.52 | 0.00 | 0.00 |
March | 1224.13 | 891.05 | 1205.51 | 665.11 | 540.40 | 0.00 | 0.00 |
April | 1103.72 | 770.39 | 1135.04 | 480.56 | 654.48 | 0.00 | 0.00 |
May | 1579.40 | 508.41 | 1387.31 | 489.08 | 898.23 | 0.00 | 0.00 |
June | 2305.42 | 302.70 | 1696.77 | 816.38 | 880.39 | 0.00 | 0.00 |
July | 1882.79 | 277.53 | 1382.46 | 506.37 | 876.09 | 0.00 | 0.00 |
August | 1939.68 | 308.77 | 1442.90 | 712.81 | 730.09 | 0.00 | 0.00 |
September | 1645.82 | 457.58 | 1279.42 | 613.57 | 665.85 | 0.00 | 0.00 |
October | 1174.89 | 897.55 | 1076.33 | 615.20 | 461.13 | 0.00 | 0.00 |
November | 878.36 | 1043.86 | 883.19 | 536.20 | 346.98 | 0.00 | 0.00 |
December | 634.71 | 1258.52 | 713.37 | 421.41 | 291.96 | 0.00 | 0.00 |
Annual Sum or Average | 1350.06 | 748.51 | 1174.16 | 585.60 | 588.56 | 0.00 | 0.00 |
Minimum of Months | 634.71 | 277.53 | 713.37 | 421.41 | 291.96 | 0.00 | 0.00 |
Maximum of Months | 2305.42 | 1258.52 | 1696.77 | 816.38 | 898.23 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 84.78 | 1814.13 | 384.45 | 0.00 | 384.45 | 0.00 | 0.00 |
February | 109.97 | 1824.40 | 483.21 | 0.00 | 483.21 | 0.00 | 0.00 |
March | 337.31 | 1374.10 | 657.49 | 0.00 | 657.49 | 0.00 | 0.00 |
April | 497.28 | 1186.52 | 825.72 | 4.58 | 821.14 | 0.00 | 0.00 |
May | 1065.26 | 704.38 | 1127.98 | 37.29 | 1090.69 | 0.00 | 0.00 |
June | 1672.38 | 395.20 | 1236.91 | 137.13 | 1099.78 | 0.00 | 0.00 |
July | 1599.07 | 373.11 | 1169.78 | 75.72 | 1094.06 | 0.00 | 0.00 |
August | 1210.79 | 439.14 | 931.06 | 22.03 | 909.03 | 0.00 | 0.00 |
September | 888.58 | 700.47 | 782.09 | 0.18 | 781.90 | 0.00 | 0.00 |
October | 309.63 | 1444.98 | 560.16 | 0.00 | 560.16 | 0.00 | 0.00 |
November | 123.31 | 1700.75 | 425.23 | 0.00 | 425.23 | 0.00 | 0.00 |
December | 68.28 | 2074.33 | 359.71 | 0.00 | 359.71 | 0.00 | 0.00 |
Annual Sum or Average | 667.00 | 1165.81 | 746.68 | 23.13 | 723.55 | 0.00 | 0.00 |
Minimum of Months | 68.28 | 373.11 | 359.71 | 0.00 | 359.71 | 0.00 | 0.00 |
Maximum of Months | 1672.38 | 2074.33 | 1236.91 | 137.13 | 1099.78 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 727.94 | 1158.10 | 802.57 | 491.84 | 310.73 | 0.00 | 0.00 |
February | 1020.98 | 1189.57 | 1066.13 | 673.04 | 393.09 | 0.00 | 0.00 |
March | 1328.49 | 910.33 | 1286.78 | 750.57 | 536.22 | 0.00 | 0.00 |
April | 1333.30 | 799.94 | 1319.67 | 642.83 | 676.84 | 0.00 | 0.00 |
May | 1769.75 | 491.74 | 1542.67 | 644.38 | 898.29 | 0.00 | 0.00 |
June | 2540.02 | 277.54 | 1882.22 | 988.11 | 894.11 | 0.00 | 0.00 |
July | 2328.60 | 263.05 | 1711.08 | 814.77 | 896.31 | 0.00 | 0.00 |
August | 2329.13 | 309.44 | 1725.86 | 950.54 | 775.32 | 0.00 | 0.00 |
September | 1832.73 | 464.98 | 1436.01 | 780.08 | 655.93 | 0.00 | 0.00 |
October | 1093.14 | 965.72 | 1039.95 | 569.83 | 470.12 | 0.00 | 0.00 |
November | 763.00 | 1116.92 | 809.47 | 457.03 | 352.44 | 0.00 | 0.00 |
December | 603.97 | 1329.74 | 700.79 | 403.70 | 297.08 | 0.00 | 0.00 |
Annual Sum or Average | 1474.72 | 770.85 | 1277.74 | 680.22 | 597.51 | 0.00 | 0.00 |
Minimum of Months | 603.97 | 263.05 | 700.79 | 403.70 | 297.08 | 0.00 | 0.00 |
Maximum of Months | 2540.02 | 1329.74 | 1882.22 | 988.11 | 898.29 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 4249.71 | 1752.33 | 3684.49 | 3030.88 | 653.60 | 0.00 | 0.00 |
February | 4055.52 | 1793.61 | 3534.11 | 2817.61 | 716.50 | 0.00 | 0.00 |
March | 3040.16 | 1405.04 | 2605.62 | 1714.34 | 891.28 | 0.00 | 0.00 |
April | 1811.79 | 1252.59 | 1687.60 | 678.59 | 1009.01 | 0.00 | 0.00 |
May | 1812.36 | 776.20 | 1546.50 | 283.46 | 1263.04 | 0.00 | 0.00 |
June | 2081.76 | 436.83 | 1425.83 | 260.60 | 1165.23 | 0.00 | 0.00 |
July | 2168.09 | 406.40 | 1484.25 | 265.79 | 1218.46 | 0.00 | 0.00 |
August | 2760.45 | 481.25 | 1889.75 | 789.98 | 1099.77 | 0.00 | 0.00 |
September | 3319.33 | 749.34 | 2431.34 | 1356.67 | 1074.67 | 0.00 | 0.00 |
October | 3536.18 | 1486.13 | 2907.16 | 2062.69 | 844.47 | 0.00 | 0.00 |
November | 4167.27 | 1698.52 | 3541.97 | 2823.46 | 718.51 | 0.00 | 0.00 |
December | 3831.02 | 1954.26 | 3387.05 | 2741.43 | 645.62 | 0.00 | 0.00 |
Annual Sum or Average | 3063.82 | 1179.31 | 2504.67 | 1561.69 | 942.98 | 0.00 | 0.00 |
Minimum of Months | 1811.79 | 406.40 | 1425.83 | 260.60 | 645.62 | 0.00 | 0.00 |
Maximum of Months | 4249.71 | 1954.26 | 3684.49 | 3030.88 | 1263.04 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 831.35 | 1190.67 | 853.76 | 540.99 | 312.77 | 0.00 | 0.00 |
February | 994.25 | 1208.75 | 1029.51 | 637.99 | 391.52 | 0.00 | 0.00 |
March | 1238.80 | 926.90 | 1205.49 | 665.09 | 540.40 | 0.00 | 0.00 |
April | 1115.14 | 817.25 | 1135.03 | 480.55 | 654.48 | 0.00 | 0.00 |
May | 1597.48 | 521.19 | 1387.29 | 489.07 | 898.22 | 0.00 | 0.00 |
June | 2321.80 | 312.57 | 1696.74 | 816.37 | 880.38 | 0.00 | 0.00 |
July | 1899.09 | 282.68 | 1382.45 | 506.36 | 876.08 | 0.00 | 0.00 |
August | 1948.86 | 325.60 | 1442.88 | 712.80 | 730.08 | 0.00 | 0.00 |
September | 1645.78 | 496.73 | 1279.40 | 613.56 | 665.85 | 0.00 | 0.00 |
October | 1167.16 | 985.65 | 1076.32 | 615.19 | 461.12 | 0.00 | 0.00 |
November | 871.07 | 1133.92 | 883.17 | 536.19 | 346.98 | 0.00 | 0.00 |
December | 632.77 | 1337.47 | 713.36 | 421.40 | 291.96 | 0.00 | 0.00 |
Annual Sum or Average | 1356.80 | 792.70 | 1174.15 | 585.59 | 588.56 | 0.00 | 0.00 |
Minimum of Months | 632.77 | 282.68 | 713.36 | 421.40 | 291.96 | 0.00 | 0.00 |
Maximum of Months | 2321.80 | 1337.47 | 1696.74 | 816.37 | 898.22 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 74.66 | 1863.97 | 384.46 | 0.00 | 384.46 | 0.00 | 0.00 |
February | 94.18 | 1879.02 | 483.22 | 0.00 | 483.22 | 0.00 | 0.00 |
March | 305.15 | 1431.46 | 657.51 | 0.00 | 657.51 | 0.00 | 0.00 |
April | 462.14 | 1232.11 | 825.73 | 4.58 | 821.15 | 0.00 | 0.00 |
May | 1020.98 | 741.10 | 1128.00 | 37.29 | 1090.72 | 0.00 | 0.00 |
June | 1645.23 | 412.45 | 1236.93 | 137.13 | 1099.80 | 0.00 | 0.00 |
July | 1574.38 | 390.60 | 1169.80 | 75.72 | 1094.08 | 0.00 | 0.00 |
August | 1197.12 | 449.38 | 931.07 | 22.03 | 909.05 | 0.00 | 0.00 |
September | 883.52 | 697.30 | 782.10 | 0.18 | 781.92 | 0.00 | 0.00 |
October | 305.39 | 1432.76 | 560.17 | 0.00 | 560.17 | 0.00 | 0.00 |
November | 119.73 | 1698.29 | 425.24 | 0.00 | 425.24 | 0.00 | 0.00 |
December | 65.20 | 2077.67 | 359.71 | 0.00 | 359.71 | 0.00 | 0.00 |
Annual Sum or Average | 648.73 | 1188.53 | 746.69 | 23.13 | 723.56 | 0.00 | 0.00 |
Minimum of Months | 65.20 | 390.60 | 359.71 | 0.00 | 359.71 | 0.00 | 0.00 |
Maximum of Months | 1645.23 | 2077.67 | 1236.93 | 137.13 | 1099.80 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 714.42 | 1168.59 | 802.58 | 491.85 | 310.74 | 0.00 | 0.00 |
February | 1003.20 | 1201.81 | 1066.14 | 673.05 | 393.09 | 0.00 | 0.00 |
March | 1306.10 | 919.78 | 1286.81 | 750.58 | 536.22 | 0.00 | 0.00 |
April | 1311.81 | 802.69 | 1319.69 | 642.84 | 676.85 | 0.00 | 0.00 |
May | 1744.46 | 500.22 | 1542.70 | 644.39 | 898.31 | 0.00 | 0.00 |
June | 2523.15 | 277.49 | 1882.25 | 988.13 | 894.12 | 0.00 | 0.00 |
July | 2313.17 | 262.97 | 1711.11 | 814.79 | 896.32 | 0.00 | 0.00 |
August | 2319.09 | 301.54 | 1725.89 | 950.56 | 775.33 | 0.00 | 0.00 |
September | 1827.38 | 447.53 | 1436.03 | 780.09 | 655.94 | 0.00 | 0.00 |
October | 1087.90 | 934.82 | 1039.97 | 569.84 | 470.13 | 0.00 | 0.00 |
November | 757.81 | 1094.47 | 809.48 | 457.04 | 352.44 | 0.00 | 0.00 |
December | 597.41 | 1315.11 | 700.80 | 403.71 | 297.09 | 0.00 | 0.00 |
Annual Sum or Average | 1460.97 | 766.60 | 1277.76 | 680.24 | 597.52 | 0.00 | 0.00 |
Minimum of Months | 597.41 | 262.97 | 700.80 | 403.71 | 297.09 | 0.00 | 0.00 |
Maximum of Months | 2523.15 | 1315.11 | 1882.25 | 988.13 | 898.31 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 4222.29 | 1700.37 | 3684.63 | 3031.01 | 653.63 | 0.00 | 0.00 |
February | 4013.80 | 1762.66 | 3534.25 | 2817.72 | 716.52 | 0.00 | 0.00 |
March | 2999.32 | 1407.62 | 2605.72 | 1714.42 | 891.30 | 0.00 | 0.00 |
April | 1771.89 | 1269.96 | 1687.66 | 678.61 | 1009.04 | 0.00 | 0.00 |
May | 1765.45 | 813.56 | 1546.55 | 283.47 | 1263.08 | 0.00 | 0.00 |
June | 2055.97 | 453.13 | 1425.87 | 260.61 | 1165.26 | 0.00 | 0.00 |
July | 2144.88 | 420.00 | 1484.30 | 265.80 | 1218.50 | 0.00 | 0.00 |
August | 2746.11 | 475.08 | 1889.81 | 790.01 | 1099.80 | 0.00 | 0.00 |
September | 3310.85 | 715.45 | 2431.43 | 1356.72 | 1074.70 | 0.00 | 0.00 |
October | 3524.26 | 1420.87 | 2907.28 | 2062.78 | 844.50 | 0.00 | 0.00 |
November | 4145.35 | 1626.38 | 3542.11 | 2823.58 | 718.53 | 0.00 | 0.00 |
December | 3803.56 | 1889.75 | 3387.18 | 2741.54 | 645.64 | 0.00 | 0.00 |
Annual Sum or Average | 3036.41 | 1159.58 | 2504.77 | 1561.76 | 943.01 | 0.00 | 0.00 |
Minimum of Months | 1765.45 | 420.00 | 1425.87 | 260.61 | 645.64 | 0.00 | 0.00 |
Maximum of Months | 4222.29 | 1889.75 | 3684.63 | 3031.01 | 1263.08 | 0.00 | 0.00 |
Report: WindowZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN RATE [W] | ZONE WINDOWS TOTAL HEAT LOSS RATE [W] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] | |
January | 818.61 | 1198.08 | 853.77 | 540.99 | 312.77 | 0.00 | 0.00 |
February | 977.76 | 1218.89 | 1029.52 | 638.00 | 391.52 | 0.00 | 0.00 |
March | 1217.67 | 940.25 | 1205.51 | 665.11 | 540.40 | 0.00 | 0.00 |
April | 1095.60 | 824.48 | 1135.04 | 480.56 | 654.48 | 0.00 | 0.00 |
May | 1574.33 | 532.37 | 1387.31 | 489.08 | 898.23 | 0.00 | 0.00 |
June | 2309.02 | 312.19 | 1696.77 | 816.38 | 880.39 | 0.00 | 0.00 |
July | 1886.37 | 285.76 | 1382.46 | 506.37 | 876.09 | 0.00 | 0.00 |
August | 1941.73 | 319.88 | 1442.90 | 712.81 | 730.09 | 0.00 | 0.00 |
September | 1643.60 | 479.27 | 1279.42 | 613.57 | 665.85 | 0.00 | 0.00 |
October | 1165.83 | 953.51 | 1076.33 | 615.20 | 461.13 | 0.00 | 0.00 |
November | 867.63 | 1108.98 | 883.19 | 536.20 | 346.98 | 0.00 | 0.00 |
December | 626.96 | 1321.08 | 713.37 | 421.41 | 291.96 | 0.00 | 0.00 |
Annual Sum or Average | 1345.29 | 788.92 | 1174.16 | 585.60 | 588.56 | 0.00 | 0.00 |
Minimum of Months | 626.96 | 285.76 | 713.37 | 421.41 | 291.96 | 0.00 | 0.00 |
Maximum of Months | 2309.02 | 1321.08 | 1696.77 | 816.38 | 898.23 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.227115E+09 | 0.471342E+10 | 0.102974E+10 | 0.00 | 0.102974E+10 | 0.00 | 0.00 |
February | 0.250365E+09 | 0.432935E+10 | 0.116901E+10 | 0.00 | 0.116901E+10 | 0.00 | 0.00 |
March | 0.846498E+09 | 0.363233E+10 | 0.176107E+10 | 0.00 | 0.176107E+10 | 0.00 | 0.00 |
April | 0.123092E+10 | 0.298031E+10 | 0.214030E+10 | 11873484.46 | 0.212843E+10 | 0.00 | 0.00 |
May | 0.277031E+10 | 0.189873E+10 | 0.302124E+10 | 99870170.09 | 0.292137E+10 | 0.00 | 0.00 |
June | 0.425912E+10 | 0.104169E+10 | 0.320613E+10 | 0.355452E+09 | 0.285068E+10 | 0.00 | 0.00 |
July | 0.420865E+10 | 0.102044E+10 | 0.313320E+10 | 0.202818E+09 | 0.293038E+10 | 0.00 | 0.00 |
August | 0.320427E+10 | 0.116252E+10 | 0.249379E+10 | 58994652.25 | 0.243479E+10 | 0.00 | 0.00 |
September | 0.230399E+10 | 0.172208E+10 | 0.202721E+10 | 476155.58 | 0.202673E+10 | 0.00 | 0.00 |
October | 0.858053E+09 | 0.360306E+10 | 0.150037E+10 | 0.00 | 0.150037E+10 | 0.00 | 0.00 |
November | 0.345661E+09 | 0.413630E+10 | 0.110223E+10 | 0.00 | 0.110223E+10 | 0.00 | 0.00 |
December | 0.193778E+09 | 0.530500E+10 | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.206987E+11 | 0.355452E+11 | 0.235478E+11 | 0.729484E+09 | 0.228183E+11 | 0.00 | 0.00 |
Minimum of Months | 0.193778E+09 | 0.102044E+10 | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.00 | 0.00 |
Maximum of Months | 0.425912E+10 | 0.530500E+10 | 0.320613E+10 | 0.355452E+09 | 0.293038E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.195719E+10 | 0.295746E+10 | 0.214964E+10 | 0.131736E+10 | 0.832275E+09 | 0.00 | 0.00 |
February | 0.245710E+10 | 0.277228E+10 | 0.257921E+10 | 0.162825E+10 | 0.950966E+09 | 0.00 | 0.00 |
March | 0.352558E+10 | 0.234109E+10 | 0.344658E+10 | 0.201036E+10 | 0.143622E+10 | 0.00 | 0.00 |
April | 0.342793E+10 | 0.194729E+10 | 0.342063E+10 | 0.166625E+10 | 0.175438E+10 | 0.00 | 0.00 |
May | 0.469676E+10 | 0.128621E+10 | 0.413195E+10 | 0.172593E+10 | 0.240602E+10 | 0.00 | 0.00 |
June | 0.654024E+10 | 0.700664E+09 | 0.487878E+10 | 0.256123E+10 | 0.231755E+10 | 0.00 | 0.00 |
July | 0.619452E+10 | 0.686425E+09 | 0.458304E+10 | 0.218233E+10 | 0.240071E+10 | 0.00 | 0.00 |
August | 0.621395E+10 | 0.780723E+09 | 0.462263E+10 | 0.254598E+10 | 0.207665E+10 | 0.00 | 0.00 |
September | 0.474968E+10 | 0.111095E+10 | 0.372219E+10 | 0.202200E+10 | 0.170019E+10 | 0.00 | 0.00 |
October | 0.294224E+10 | 0.236186E+10 | 0.278546E+10 | 0.152627E+10 | 0.125919E+10 | 0.00 | 0.00 |
November | 0.200508E+10 | 0.267140E+10 | 0.209818E+10 | 0.118466E+10 | 0.913528E+09 | 0.00 | 0.00 |
December | 0.163554E+10 | 0.335767E+10 | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.463458E+11 | 0.229740E+11 | 0.402953E+11 | 0.214519E+11 | 0.188434E+11 | 0.00 | 0.00 |
Minimum of Months | 0.163554E+10 | 0.686425E+09 | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.00 | 0.00 |
Maximum of Months | 0.654024E+10 | 0.335767E+10 | 0.487878E+10 | 0.256123E+10 | 0.240602E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.113690E+11 | 0.431293E+10 | 0.986892E+10 | 0.811825E+10 | 0.175067E+10 | 0.00 | 0.00 |
February | 0.974591E+10 | 0.406381E+10 | 0.855005E+10 | 0.681664E+10 | 0.173341E+10 | 0.00 | 0.00 |
March | 0.805954E+10 | 0.357925E+10 | 0.697916E+10 | 0.459189E+10 | 0.238727E+10 | 0.00 | 0.00 |
April | 0.462085E+10 | 0.307882E+10 | 0.437441E+10 | 0.175897E+10 | 0.261544E+10 | 0.00 | 0.00 |
May | 0.474862E+10 | 0.208145E+10 | 0.414228E+10 | 0.759251E+09 | 0.338303E+10 | 0.00 | 0.00 |
June | 0.531745E+10 | 0.113831E+10 | 0.369585E+10 | 0.675498E+09 | 0.302035E+10 | 0.00 | 0.00 |
July | 0.573146E+10 | 0.109227E+10 | 0.397554E+10 | 0.711908E+09 | 0.326363E+10 | 0.00 | 0.00 |
August | 0.734534E+10 | 0.122781E+10 | 0.506167E+10 | 0.211597E+10 | 0.294570E+10 | 0.00 | 0.00 |
September | 0.858525E+10 | 0.177372E+10 | 0.630226E+10 | 0.351663E+10 | 0.278563E+10 | 0.00 | 0.00 |
October | 0.946976E+10 | 0.359399E+10 | 0.778685E+10 | 0.552495E+10 | 0.226190E+10 | 0.00 | 0.00 |
November | 0.107919E+11 | 0.398462E+10 | 0.918115E+10 | 0.731871E+10 | 0.186244E+10 | 0.00 | 0.00 |
December | 0.102394E+11 | 0.482001E+10 | 0.907223E+10 | 0.734294E+10 | 0.172929E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.960245E+11 | 0.347470E+11 | 0.789904E+11 | 0.492516E+11 | 0.297388E+11 | 0.00 | 0.00 |
Minimum of Months | 0.462085E+10 | 0.109227E+10 | 0.369585E+10 | 0.675498E+09 | 0.172929E+10 | 0.00 | 0.00 |
Maximum of Months | 0.113690E+11 | 0.482001E+10 | 0.986892E+10 | 0.811825E+10 | 0.338303E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.221893E+10 | 0.303108E+10 | 0.228674E+10 | 0.144900E+10 | 0.837735E+09 | 0.00 | 0.00 |
February | 0.238337E+10 | 0.280713E+10 | 0.249063E+10 | 0.154345E+10 | 0.947175E+09 | 0.00 | 0.00 |
March | 0.327871E+10 | 0.238658E+10 | 0.322883E+10 | 0.178142E+10 | 0.144741E+10 | 0.00 | 0.00 |
April | 0.286085E+10 | 0.199686E+10 | 0.294203E+10 | 0.124560E+10 | 0.169642E+10 | 0.00 | 0.00 |
May | 0.423026E+10 | 0.136174E+10 | 0.371577E+10 | 0.130995E+10 | 0.240582E+10 | 0.00 | 0.00 |
June | 0.597564E+10 | 0.784591E+09 | 0.439802E+10 | 0.211606E+10 | 0.228196E+10 | 0.00 | 0.00 |
July | 0.504287E+10 | 0.743333E+09 | 0.370279E+10 | 0.135626E+10 | 0.234652E+10 | 0.00 | 0.00 |
August | 0.519523E+10 | 0.827017E+09 | 0.386466E+10 | 0.190920E+10 | 0.195546E+10 | 0.00 | 0.00 |
September | 0.426596E+10 | 0.118606E+10 | 0.331625E+10 | 0.159036E+10 | 0.172589E+10 | 0.00 | 0.00 |
October | 0.314682E+10 | 0.240399E+10 | 0.288284E+10 | 0.164776E+10 | 0.123508E+10 | 0.00 | 0.00 |
November | 0.227670E+10 | 0.270568E+10 | 0.228922E+10 | 0.138984E+10 | 0.899379E+09 | 0.00 | 0.00 |
December | 0.170001E+10 | 0.337083E+10 | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.425753E+11 | 0.236049E+11 | 0.370285E+11 | 0.184676E+11 | 0.185609E+11 | 0.00 | 0.00 |
Minimum of Months | 0.170001E+10 | 0.743333E+09 | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.00 | 0.00 |
Maximum of Months | 0.597564E+10 | 0.337083E+10 | 0.439802E+10 | 0.211606E+10 | 0.240582E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.227085E+09 | 0.485896E+10 | 0.102972E+10 | 0.00 | 0.102972E+10 | 0.00 | 0.00 |
February | 0.266035E+09 | 0.441359E+10 | 0.116899E+10 | 0.00 | 0.116899E+10 | 0.00 | 0.00 |
March | 0.903452E+09 | 0.368039E+10 | 0.176103E+10 | 0.00 | 0.176103E+10 | 0.00 | 0.00 |
April | 0.128894E+10 | 0.307545E+10 | 0.214026E+10 | 11873135.46 | 0.212839E+10 | 0.00 | 0.00 |
May | 0.285319E+10 | 0.188661E+10 | 0.302118E+10 | 99867234.64 | 0.292131E+10 | 0.00 | 0.00 |
June | 0.433481E+10 | 0.102435E+10 | 0.320607E+10 | 0.355441E+09 | 0.285063E+10 | 0.00 | 0.00 |
July | 0.428296E+10 | 0.999335E+09 | 0.313313E+10 | 0.202812E+09 | 0.293032E+10 | 0.00 | 0.00 |
August | 0.324299E+10 | 0.117618E+10 | 0.249374E+10 | 58992918.24 | 0.243475E+10 | 0.00 | 0.00 |
September | 0.230320E+10 | 0.181563E+10 | 0.202717E+10 | 476141.58 | 0.202669E+10 | 0.00 | 0.00 |
October | 0.829307E+09 | 0.387024E+10 | 0.150034E+10 | 0.00 | 0.150034E+10 | 0.00 | 0.00 |
November | 0.319619E+09 | 0.440833E+10 | 0.110221E+10 | 0.00 | 0.110221E+10 | 0.00 | 0.00 |
December | 0.182882E+09 | 0.555589E+10 | 0.963435E+09 | 0.00 | 0.963435E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.210345E+11 | 0.367650E+11 | 0.235473E+11 | 0.729462E+09 | 0.228178E+11 | 0.00 | 0.00 |
Minimum of Months | 0.182882E+09 | 0.999335E+09 | 0.963435E+09 | 0.00 | 0.963435E+09 | 0.00 | 0.00 |
Maximum of Months | 0.433481E+10 | 0.555589E+10 | 0.320607E+10 | 0.355441E+09 | 0.293032E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.194972E+10 | 0.310185E+10 | 0.214960E+10 | 0.131734E+10 | 0.832266E+09 | 0.00 | 0.00 |
February | 0.246996E+10 | 0.287781E+10 | 0.257917E+10 | 0.162822E+10 | 0.950956E+09 | 0.00 | 0.00 |
March | 0.355821E+10 | 0.243823E+10 | 0.344652E+10 | 0.201032E+10 | 0.143620E+10 | 0.00 | 0.00 |
April | 0.345592E+10 | 0.207344E+10 | 0.342058E+10 | 0.166622E+10 | 0.175436E+10 | 0.00 | 0.00 |
May | 0.474010E+10 | 0.131709E+10 | 0.413189E+10 | 0.172590E+10 | 0.240599E+10 | 0.00 | 0.00 |
June | 0.658374E+10 | 0.719393E+09 | 0.487871E+10 | 0.256118E+10 | 0.231752E+10 | 0.00 | 0.00 |
July | 0.623693E+10 | 0.704546E+09 | 0.458297E+10 | 0.218229E+10 | 0.240068E+10 | 0.00 | 0.00 |
August | 0.623835E+10 | 0.828800E+09 | 0.462255E+10 | 0.254593E+10 | 0.207663E+10 | 0.00 | 0.00 |
September | 0.475043E+10 | 0.120524E+10 | 0.372213E+10 | 0.202196E+10 | 0.170017E+10 | 0.00 | 0.00 |
October | 0.292788E+10 | 0.258659E+10 | 0.278542E+10 | 0.152624E+10 | 0.125917E+10 | 0.00 | 0.00 |
November | 0.197771E+10 | 0.289505E+10 | 0.209815E+10 | 0.118463E+10 | 0.913518E+09 | 0.00 | 0.00 |
December | 0.161768E+10 | 0.356158E+10 | 0.187698E+10 | 0.108127E+10 | 0.795712E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.465066E+11 | 0.243096E+11 | 0.402947E+11 | 0.214515E+11 | 0.188432E+11 | 0.00 | 0.00 |
Minimum of Months | 0.161768E+10 | 0.704546E+09 | 0.187698E+10 | 0.108127E+10 | 0.795712E+09 | 0.00 | 0.00 |
Maximum of Months | 0.658374E+10 | 0.356158E+10 | 0.487871E+10 | 0.256118E+10 | 0.240599E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.113824E+11 | 0.469344E+10 | 0.986853E+10 | 0.811791E+10 | 0.175061E+10 | 0.00 | 0.00 |
February | 0.981110E+10 | 0.433910E+10 | 0.854971E+10 | 0.681636E+10 | 0.173336E+10 | 0.00 | 0.00 |
March | 0.814276E+10 | 0.376327E+10 | 0.697889E+10 | 0.459170E+10 | 0.238719E+10 | 0.00 | 0.00 |
April | 0.469616E+10 | 0.324671E+10 | 0.437425E+10 | 0.175889E+10 | 0.261536E+10 | 0.00 | 0.00 |
May | 0.485423E+10 | 0.207896E+10 | 0.414215E+10 | 0.759219E+09 | 0.338293E+10 | 0.00 | 0.00 |
June | 0.539591E+10 | 0.113226E+10 | 0.369574E+10 | 0.675470E+09 | 0.302027E+10 | 0.00 | 0.00 |
July | 0.580701E+10 | 0.108850E+10 | 0.397541E+10 | 0.711879E+09 | 0.326354E+10 | 0.00 | 0.00 |
August | 0.739359E+10 | 0.128899E+10 | 0.506150E+10 | 0.211588E+10 | 0.294562E+10 | 0.00 | 0.00 |
September | 0.860370E+10 | 0.194230E+10 | 0.630203E+10 | 0.351648E+10 | 0.278555E+10 | 0.00 | 0.00 |
October | 0.947129E+10 | 0.398044E+10 | 0.778655E+10 | 0.552472E+10 | 0.226183E+10 | 0.00 | 0.00 |
November | 0.108016E+11 | 0.440257E+10 | 0.918079E+10 | 0.731841E+10 | 0.186238E+10 | 0.00 | 0.00 |
December | 0.102610E+11 | 0.523428E+10 | 0.907187E+10 | 0.734263E+10 | 0.172923E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.966207E+11 | 0.371908E+11 | 0.789874E+11 | 0.492495E+11 | 0.297379E+11 | 0.00 | 0.00 |
Minimum of Months | 0.469616E+10 | 0.108850E+10 | 0.369574E+10 | 0.675470E+09 | 0.172923E+10 | 0.00 | 0.00 |
Maximum of Months | 0.113824E+11 | 0.523428E+10 | 0.986853E+10 | 0.811791E+10 | 0.338293E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.222670E+10 | 0.318910E+10 | 0.228670E+10 | 0.144898E+10 | 0.837728E+09 | 0.00 | 0.00 |
February | 0.240528E+10 | 0.292422E+10 | 0.249059E+10 | 0.154343E+10 | 0.947167E+09 | 0.00 | 0.00 |
March | 0.331801E+10 | 0.248260E+10 | 0.322879E+10 | 0.178139E+10 | 0.144740E+10 | 0.00 | 0.00 |
April | 0.289044E+10 | 0.211832E+10 | 0.294199E+10 | 0.124558E+10 | 0.169640E+10 | 0.00 | 0.00 |
May | 0.427868E+10 | 0.139595E+10 | 0.371573E+10 | 0.130993E+10 | 0.240580E+10 | 0.00 | 0.00 |
June | 0.601811E+10 | 0.810178E+09 | 0.439796E+10 | 0.211602E+10 | 0.228194E+10 | 0.00 | 0.00 |
July | 0.508651E+10 | 0.757121E+09 | 0.370274E+10 | 0.135624E+10 | 0.234650E+10 | 0.00 | 0.00 |
August | 0.521983E+10 | 0.872086E+09 | 0.386461E+10 | 0.190916E+10 | 0.195545E+10 | 0.00 | 0.00 |
September | 0.426585E+10 | 0.128752E+10 | 0.331621E+10 | 0.159034E+10 | 0.172587E+10 | 0.00 | 0.00 |
October | 0.312611E+10 | 0.263997E+10 | 0.288280E+10 | 0.164773E+10 | 0.123507E+10 | 0.00 | 0.00 |
November | 0.225780E+10 | 0.293911E+10 | 0.228919E+10 | 0.138982E+10 | 0.899371E+09 | 0.00 | 0.00 |
December | 0.169481E+10 | 0.358227E+10 | 0.191067E+10 | 0.112868E+10 | 0.781990E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.427881E+11 | 0.249985E+11 | 0.370280E+11 | 0.184673E+11 | 0.185607E+11 | 0.00 | 0.00 |
Minimum of Months | 0.169481E+10 | 0.757121E+09 | 0.191067E+10 | 0.112868E+10 | 0.781990E+09 | 0.00 | 0.00 |
Maximum of Months | 0.601811E+10 | 0.358227E+10 | 0.439796E+10 | 0.211602E+10 | 0.240580E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.199962E+09 | 0.499245E+10 | 0.102974E+10 | 0.00 | 0.102974E+10 | 0.00 | 0.00 |
February | 0.227837E+09 | 0.454574E+10 | 0.116901E+10 | 0.00 | 0.116901E+10 | 0.00 | 0.00 |
March | 0.817303E+09 | 0.383402E+10 | 0.176107E+10 | 0.00 | 0.176107E+10 | 0.00 | 0.00 |
April | 0.119786E+10 | 0.319364E+10 | 0.214030E+10 | 11873484.46 | 0.212843E+10 | 0.00 | 0.00 |
May | 0.273459E+10 | 0.198495E+10 | 0.302124E+10 | 99870170.09 | 0.292137E+10 | 0.00 | 0.00 |
June | 0.426443E+10 | 0.106908E+10 | 0.320613E+10 | 0.355452E+09 | 0.285068E+10 | 0.00 | 0.00 |
July | 0.421683E+10 | 0.104618E+10 | 0.313320E+10 | 0.202818E+09 | 0.293038E+10 | 0.00 | 0.00 |
August | 0.320637E+10 | 0.120363E+10 | 0.249379E+10 | 58994652.25 | 0.243479E+10 | 0.00 | 0.00 |
September | 0.229008E+10 | 0.180741E+10 | 0.202721E+10 | 476155.58 | 0.202673E+10 | 0.00 | 0.00 |
October | 0.817967E+09 | 0.383750E+10 | 0.150037E+10 | 0.00 | 0.150037E+10 | 0.00 | 0.00 |
November | 0.310352E+09 | 0.440196E+10 | 0.110223E+10 | 0.00 | 0.110223E+10 | 0.00 | 0.00 |
December | 0.174643E+09 | 0.556483E+10 | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.204582E+11 | 0.374814E+11 | 0.235478E+11 | 0.729484E+09 | 0.228183E+11 | 0.00 | 0.00 |
Minimum of Months | 0.174643E+09 | 0.104618E+10 | 0.963454E+09 | 0.00 | 0.963454E+09 | 0.00 | 0.00 |
Maximum of Months | 0.426443E+10 | 0.556483E+10 | 0.320613E+10 | 0.355452E+09 | 0.293038E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.191350E+10 | 0.312996E+10 | 0.214964E+10 | 0.131736E+10 | 0.832275E+09 | 0.00 | 0.00 |
February | 0.242694E+10 | 0.290743E+10 | 0.257921E+10 | 0.162825E+10 | 0.950966E+09 | 0.00 | 0.00 |
March | 0.349826E+10 | 0.246353E+10 | 0.344658E+10 | 0.201036E+10 | 0.143622E+10 | 0.00 | 0.00 |
April | 0.340022E+10 | 0.208057E+10 | 0.342063E+10 | 0.166625E+10 | 0.175438E+10 | 0.00 | 0.00 |
May | 0.467237E+10 | 0.133978E+10 | 0.413195E+10 | 0.172593E+10 | 0.240602E+10 | 0.00 | 0.00 |
June | 0.654001E+10 | 0.719263E+09 | 0.487878E+10 | 0.256123E+10 | 0.231755E+10 | 0.00 | 0.00 |
July | 0.619560E+10 | 0.704338E+09 | 0.458304E+10 | 0.218233E+10 | 0.240071E+10 | 0.00 | 0.00 |
August | 0.621146E+10 | 0.807651E+09 | 0.462263E+10 | 0.254598E+10 | 0.207665E+10 | 0.00 | 0.00 |
September | 0.473658E+10 | 0.116000E+10 | 0.372219E+10 | 0.202200E+10 | 0.170019E+10 | 0.00 | 0.00 |
October | 0.291384E+10 | 0.250382E+10 | 0.278546E+10 | 0.152627E+10 | 0.125919E+10 | 0.00 | 0.00 |
November | 0.196425E+10 | 0.283688E+10 | 0.209818E+10 | 0.118466E+10 | 0.913528E+09 | 0.00 | 0.00 |
December | 0.160010E+10 | 0.352238E+10 | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.460731E+11 | 0.241756E+11 | 0.402953E+11 | 0.214519E+11 | 0.188434E+11 | 0.00 | 0.00 |
Minimum of Months | 0.160010E+10 | 0.704338E+09 | 0.187702E+10 | 0.108129E+10 | 0.795721E+09 | 0.00 | 0.00 |
Maximum of Months | 0.654001E+10 | 0.352238E+10 | 0.487878E+10 | 0.256123E+10 | 0.240602E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.113090E+11 | 0.455428E+10 | 0.986892E+10 | 0.811825E+10 | 0.175067E+10 | 0.00 | 0.00 |
February | 0.971018E+10 | 0.426423E+10 | 0.855005E+10 | 0.681664E+10 | 0.173341E+10 | 0.00 | 0.00 |
March | 0.803338E+10 | 0.377016E+10 | 0.697916E+10 | 0.459189E+10 | 0.238727E+10 | 0.00 | 0.00 |
April | 0.459273E+10 | 0.329173E+10 | 0.437441E+10 | 0.175897E+10 | 0.261544E+10 | 0.00 | 0.00 |
May | 0.472858E+10 | 0.217905E+10 | 0.414228E+10 | 0.759251E+09 | 0.338303E+10 | 0.00 | 0.00 |
June | 0.532908E+10 | 0.117453E+10 | 0.369585E+10 | 0.675498E+09 | 0.302035E+10 | 0.00 | 0.00 |
July | 0.574485E+10 | 0.112494E+10 | 0.397554E+10 | 0.711908E+09 | 0.326363E+10 | 0.00 | 0.00 |
August | 0.735519E+10 | 0.127246E+10 | 0.506167E+10 | 0.211597E+10 | 0.294570E+10 | 0.00 | 0.00 |
September | 0.858173E+10 | 0.185445E+10 | 0.630226E+10 | 0.351663E+10 | 0.278563E+10 | 0.00 | 0.00 |
October | 0.943938E+10 | 0.380566E+10 | 0.778685E+10 | 0.552495E+10 | 0.226190E+10 | 0.00 | 0.00 |
November | 0.107447E+11 | 0.421559E+10 | 0.918115E+10 | 0.731871E+10 | 0.186244E+10 | 0.00 | 0.00 |
December | 0.101875E+11 | 0.506150E+10 | 0.907223E+10 | 0.734294E+10 | 0.172929E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.957563E+11 | 0.365686E+11 | 0.789904E+11 | 0.492516E+11 | 0.297388E+11 | 0.00 | 0.00 |
Minimum of Months | 0.459273E+10 | 0.112494E+10 | 0.369585E+10 | 0.675498E+09 | 0.172929E+10 | 0.00 | 0.00 |
Maximum of Months | 0.113090E+11 | 0.506150E+10 | 0.986892E+10 | 0.811825E+10 | 0.338303E+10 | 0.00 | 0.00 |
Report: WindowEnergyZoneSummaryMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] | ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] | ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] | ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] | |
January | 0.219256E+10 | 0.320894E+10 | 0.228674E+10 | 0.144900E+10 | 0.837735E+09 | 0.00 | 0.00 |
February | 0.236540E+10 | 0.294874E+10 | 0.249063E+10 | 0.154345E+10 | 0.947175E+09 | 0.00 | 0.00 |
March | 0.326140E+10 | 0.251837E+10 | 0.322883E+10 | 0.178142E+10 | 0.144741E+10 | 0.00 | 0.00 |
April | 0.283979E+10 | 0.213706E+10 | 0.294203E+10 | 0.124560E+10 | 0.169642E+10 | 0.00 | 0.00 |
May | 0.421669E+10 | 0.142590E+10 | 0.371577E+10 | 0.130995E+10 | 0.240582E+10 | 0.00 | 0.00 |
June | 0.598497E+10 | 0.809190E+09 | 0.439802E+10 | 0.211606E+10 | 0.228196E+10 | 0.00 | 0.00 |
July | 0.505245E+10 | 0.765368E+09 | 0.370279E+10 | 0.135626E+10 | 0.234652E+10 | 0.00 | 0.00 |
August | 0.520073E+10 | 0.856764E+09 | 0.386466E+10 | 0.190920E+10 | 0.195546E+10 | 0.00 | 0.00 |
September | 0.426022E+10 | 0.124228E+10 | 0.331625E+10 | 0.159036E+10 | 0.172589E+10 | 0.00 | 0.00 |
October | 0.312255E+10 | 0.255389E+10 | 0.288284E+10 | 0.164776E+10 | 0.123508E+10 | 0.00 | 0.00 |
November | 0.224890E+10 | 0.287447E+10 | 0.228922E+10 | 0.138984E+10 | 0.899379E+09 | 0.00 | 0.00 |
December | 0.167926E+10 | 0.353839E+10 | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.00 | 0.00 |
Annual Sum or Average | 0.424249E+11 | 0.248794E+11 | 0.370285E+11 | 0.184676E+11 | 0.185609E+11 | 0.00 | 0.00 |
Minimum of Months | 0.167926E+10 | 0.765368E+09 | 0.191070E+10 | 0.112870E+10 | 0.781997E+09 | 0.00 | 0.00 |
Maximum of Months | 0.598497E+10 | 0.353839E+10 | 0.439802E+10 | 0.211606E+10 | 0.240582E+10 | 0.00 | 0.00 |
Report: AverageOutdoorConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] | SITE WIND SPEED [m/s] | SITE SKY TEMPERATURE [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] | SITE RAIN STATUS [] | |
January | 0.85 | -1.5 | -4.5 | 2.30 | -12.1 | 27.63 | 226.20 | 0.01 |
February | -0.2 | -2.7 | -6.1 | 3.74 | -13.6 | 32.55 | 253.27 | 0.01 |
March | 4.82 | 0.36 | -5.5 | 4.48 | -7.8 | 54.65 | 233.06 | 0.03 |
April | 6.08 | 2.29 | -2.0 | 5.23 | -4.9 | 81.86 | 179.11 | 0.05 |
May | 13.74 | 7.52 | 1.82 | 4.10 | 2.75 | 117.64 | 180.87 | 0.01 |
June | 22.16 | 12.46 | 5.10 | 4.19 | 9.76 | 95.26 | 290.95 | 0.00 |
July | 22.71 | 13.25 | 6.43 | 4.25 | 12.01 | 110.54 | 215.12 | 0.03 |
August | 21.74 | 12.79 | 6.20 | 3.81 | 10.76 | 77.72 | 272.61 | 0.02 |
September | 18.54 | 9.35 | 1.35 | 4.13 | 5.52 | 70.51 | 233.03 | 0.01 |
October | 7.12 | 2.51 | -2.7 | 3.54 | -5.8 | 44.60 | 216.74 | 0.01 |
November | 3.03 | 0.31 | -2.9 | 2.79 | -8.8 | 30.71 | 220.86 | 0.01 |
December | -1.0 | -4.5 | -9.5 | 4.43 | -15.4 | 27.45 | 194.75 | 0.01 |
Annual Sum or Average | 10.02 | 4.37 | -1.0 | 3.91 | -2.2 | 64.46 | 226.11 | 0.02 |
Minimum of Months | -1.0 | -4.5 | -9.5 | 2.30 | -15.4 | 27.45 | 179.11 | 0.00 |
Maximum of Months | 22.71 | 13.25 | 6.43 | 5.23 | 12.01 | 117.64 | 290.95 | 0.05 |
Report: OutdoorConditionsMaximumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 21.00 | 20-JAN-12:00 | 6.97 | -11.0 | 0.50 | 6.55 | 41.00 | 961.00 |
February | 20.00 | 18-FEB-12:00 | 7.74 | -5.0 | 3.60 | 6.35 | 56.00 | 998.00 |
March | 24.00 | 14-MAR-12:00 | 7.90 | -12.0 | 3.10 | 11.65 | 160.00 | 837.50 |
April | 22.00 | 19-APR-13:09 | 8.49 | -5.7 | 5.52 | 11.55 | 235.67 | 789.67 |
May | 29.00 | 17-MAY-12:00 | 11.92 | -3.0 | 5.10 | 18.99 | 432.50 | 162.00 |
June | 39.40 | 26-JUN-14:00 | 15.63 | -2.8 | 4.60 | 21.96 | 136.50 | 752.00 |
July | 37.00 | 16-JUL-12:00 | 14.90 | -3.0 | 3.10 | 26.65 | 319.50 | 109.50 |
August | 37.00 | 16-AUG-13:00 | 16.36 | 3.00 | 3.60 | 28.27 | 90.00 | 895.00 |
September | 32.70 | 09-SEP-12:00 | 13.05 | -3.9 | 3.00 | 16.30 | 270.50 | 562.00 |
October | 27.00 | 11-OCT-13:00 | 9.73 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
November | 22.00 | 06-NOV-13:09 | 7.10 | -13.0 | 2.60 | 4.92 | 88.67 | 883.33 |
December | 22.00 | 01-DEC-13:00 | 7.94 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 20.00 | 6.97 | -13.0 | 0.50 | 4.92 | 41.00 | 109.50 | |
Maximum of Months | 39.40 | 16.36 | 3.00 | 5.52 | 28.27 | 432.50 | 998.00 |
Report: OutdoorConditionsMinimumDryBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] | SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | -19.0 | 05-JAN-18:00 | -19.0 | -19.0 | 1.50 | -37.1 | 0.00 | 0.00 |
February | -20.0 | 12-FEB-04:00 | -20.0 | -20.0 | 3.60 | -39.1 | 0.00 | 0.00 |
March | -15.6 | 19-MAR-06:00 | -15.6 | -15.6 | 10.80 | -25.3 | 24.00 | 0.00 |
April | -8.0 | 03-APR-02:00 | -8.0 | -8.0 | 3.10 | -22.2 | 0.00 | 0.00 |
May | -1.0 | 03-MAY-01:00 | -2.4 | -4.0 | 4.10 | -15.7 | 0.00 | 0.00 |
June | 6.60 | 09-JUN-03:00 | 3.45 | 0.00 | 3.60 | -6.9 | 0.00 | 0.00 |
July | 9.00 | 02-JUL-04:00 | 3.30 | -3.0 | 3.60 | -5.3 | 20.00 | 184.50 |
August | 11.00 | 12-AUG-22:00 | 7.22 | 4.00 | 4.10 | 5.13 | 0.00 | 0.00 |
September | -1.7 | 22-SEP-05:10 | -2.9 | -4.3 | 3.60 | -15.8 | 0.00 | 0.00 |
October | -10.0 | 30-OCT-03:00 | -10.0 | -10.0 | 2.60 | -18.6 | 0.00 | 0.00 |
November | -15.0 | 29-NOV-20:00 | -15.0 | -15.0 | 3.10 | -33.5 | 0.00 | 0.00 |
December | -23.0 | 22-DEC-02:00 | -23.0 | -23.0 | 3.60 | -42.7 | 0.00 | 0.00 |
Annual Sum or Average | ||||||||
Minimum of Months | -23.0 | -23.0 | -23.0 | 1.50 | -42.7 | 0.00 | 0.00 | |
Maximum of Months | 11.00 | 7.22 | 4.00 | 10.80 | 5.13 | 24.00 | 184.50 |
Report: OutdoorConditionsMaximumWetBulbMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 7.55 | 20-JAN-11:00 | 20.00 | -6.0 | 2.60 | 7.95 | 43.00 | 971.50 |
February | 7.98 | 18-FEB-14:00 | 19.00 | -3.0 | 3.60 | 5.94 | 151.00 | 410.00 |
March | 8.00 | 31-MAR-17:00 | 15.00 | 2.00 | 2.60 | 1.58 | 19.50 | 261.00 |
April | 12.50 | 28-APR-13:00 | 18.00 | 9.00 | 9.80 | 9.72 | 335.00 | 196.50 |
May | 14.87 | 31-MAY-13:00 | 28.00 | 7.00 | 4.60 | 14.47 | 157.50 | 830.50 |
June | 19.65 | 18-JUN-11:00 | 29.40 | 15.50 | 6.10 | 16.85 | 272.50 | 596.00 |
July | 19.75 | 30-JUL-13:00 | 29.00 | 16.00 | 3.60 | 18.99 | 217.50 | 412.00 |
August | 18.80 | 05-AUG-14:09 | 25.83 | 15.33 | 6.62 | 20.54 | 196.33 | 4.00 |
September | 14.95 | 01-SEP-11:00 | 24.40 | 9.40 | 3.00 | 10.69 | 193.50 | 684.00 |
October | 9.73 | 11-OCT-13:00 | 27.00 | -9.0 | 4.60 | 12.03 | 89.50 | 844.00 |
November | 9.33 | 09-NOV-10:00 | 20.00 | 0.00 | 1.50 | 11.07 | 112.00 | 860.50 |
December | 7.94 | 01-DEC-13:00 | 22.00 | -8.0 | 2.60 | 5.13 | 49.00 | 862.00 |
Annual Sum or Average | ||||||||
Minimum of Months | 7.55 | 15.00 | -9.0 | 1.50 | 1.58 | 19.50 | 4.00 | |
Maximum of Months | 19.75 | 29.40 | 16.00 | 9.80 | 20.54 | 335.00 | 971.50 |
Report: OutdoorConditionsMaximumDewPointMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] | SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} | SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] | SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] | SITE WIND SPEED {AT MAX/MIN} [m/s] | SITE SKY TEMPERATURE {AT MAX/MIN} [C] | SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] | |
January | 5.00 | 28-JAN-10:00 | 5.00 | 5.00 | 1.00 | -6.2 | 207.00 | 309.00 |
February | 5.00 | 19-FEB-14:30 | 5.00 | 5.00 | 1.80 | -0.4 | 188.00 | 467.00 |
March | 7.00 | 17-MAR-14:00 | 8.00 | 7.39 | 8.20 | 1.16 | 121.50 | 3.00 |
April | 9.00 | 28-APR-13:00 | 18.00 | 12.50 | 9.80 | 9.72 | 335.00 | 196.50 |
May | 11.00 | 21-MAY-21:10 | 12.83 | 11.73 | 2.68 | 6.78 | 0.00 | 0.00 |
June | 15.50 | 18-JUN-11:00 | 29.40 | 19.65 | 6.10 | 16.85 | 272.50 | 596.00 |
July | 17.00 | 28-JUL-16:00 | 20.00 | 17.92 | 5.70 | 15.02 | 155.00 | 32.00 |
August | 18.00 | 04-AUG-01:00 | 18.00 | 18.00 | 2.60 | 8.74 | 0.00 | 0.00 |
September | 12.20 | 30-SEP-14:00 | 17.20 | 13.90 | 5.10 | 9.72 | 209.00 | 82.50 |
October | 6.00 | 01-OCT-19:00 | 9.00 | 7.28 | 3.10 | 3.69 | 0.00 | 0.00 |
November | 7.00 | 09-NOV-23:00 | 8.00 | 7.40 | 4.10 | 3.06 | 0.00 | 0.00 |
December | 1.00 | 30-DEC-14:00 | 7.00 | 4.06 | 9.80 | -1.2 | 101.00 | 91.50 |
Annual Sum or Average | ||||||||
Minimum of Months | 1.00 | 5.00 | 4.06 | 1.00 | -6.2 | 0.00 | 0.00 | |
Maximum of Months | 18.00 | 29.40 | 19.65 | 9.80 | 16.85 | 335.00 | 596.00 |
Report: OutdoorGroundConditionsMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE GROUND TEMPERATURE [C] | SITE SURFACE GROUND TEMPERATURE [C] | SITE DEEP GROUND TEMPERATURE [C] | SITE MAINS WATER TEMPERATURE [C] | SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] | SITE SNOW ON GROUND STATUS [] | |
January | 18.00 | 13.00 | 16.00 | 8.52 | 21.53 | 0.00 |
February | 18.00 | 13.00 | 16.00 | 7.90 | 29.36 | 0.00 |
March | 18.00 | 13.00 | 16.00 | 8.65 | 35.75 | 0.00 |
April | 18.00 | 13.00 | 16.00 | 10.64 | 38.62 | 0.00 |
May | 18.00 | 13.00 | 16.00 | 13.34 | 48.35 | 0.00 |
June | 18.00 | 13.00 | 16.00 | 16.03 | 59.81 | 0.00 |
July | 18.00 | 13.00 | 16.00 | 17.97 | 52.29 | 0.00 |
August | 18.00 | 13.00 | 16.00 | 18.66 | 51.98 | 0.00 |
September | 18.00 | 13.00 | 16.00 | 17.88 | 41.73 | 0.00 |
October | 18.00 | 13.00 | 16.00 | 15.85 | 30.82 | 0.00 |
November | 18.00 | 13.00 | 16.00 | 13.14 | 23.90 | 0.00 |
December | 18.00 | 13.00 | 16.00 | 10.46 | 18.59 | 0.00 |
Annual Sum or Average | 18.00 | 13.00 | 16.00 | 13.28 | 37.76 | 0.00 |
Minimum of Months | 18.00 | 13.00 | 16.00 | 7.90 | 18.59 | 0.00 |
Maximum of Months | 18.00 | 13.00 | 16.00 | 18.66 | 59.81 | 0.00 |
Report: WaterHeaterReportMonthly
For: SWHSYS1 WATER HEATER
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportWATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] | WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] | WATER HEATER BURNER HEATING ENERGY [] | WATER HEATER GAS CONSUMPTION [] | WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] | WATER HEATER LOSS DEMAND ENERGY [] | WATER HEATER HEAT LOSS ENERGY [J] | WATER HEATER TANK TEMPERATURE [C] | WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] | WATER HEATER SOURCE ENERGY [] | |
January | 0.547869E+10 | -0.476671E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -711980488.1 | 58.99 | 0.00 | 0.00 |
February | 0.502862E+10 | -0.438578E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -642836009.2 | 58.99 | 0.00 | 0.00 |
March | 0.582138E+10 | -0.511520E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -706178817.8 | 58.98 | 0.00 | 0.00 |
April | 0.510235E+10 | -0.442194E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -680405018.4 | 58.98 | 0.00 | 0.00 |
May | 0.517338E+10 | -0.448182E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -691563198.1 | 58.98 | 0.00 | 0.00 |
June | 0.485498E+10 | -0.418811E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -666873413.4 | 58.99 | 0.00 | 0.00 |
July | 0.445265E+10 | -0.376614E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -686511959.1 | 58.98 | 0.00 | 0.00 |
August | 0.478641E+10 | -0.409853E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -687878793.4 | 58.98 | 0.00 | 0.00 |
September | 0.442736E+10 | -0.376163E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -665728650.8 | 58.99 | 0.00 | 0.00 |
October | 0.477029E+10 | -0.407607E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -694213837.2 | 58.98 | 0.00 | 0.00 |
November | 0.493751E+10 | -0.425865E+10 | 0.00 | 0.00 | 720.00 | 0.00 | -678852213.6 | 58.98 | 0.00 | 0.00 |
December | 0.517272E+10 | -0.445678E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -715937301.5 | 58.98 | 0.00 | 0.00 |
Annual Sum or Average | 0.600063E+11 | -0.517774E+11 | 0.00 | 0.00 | 8760.00 | 0.00 | -0.822896E+10 | 58.98 | 0.00 | 0.00 |
Minimum of Months | 0.442736E+10 | -0.511520E+10 | 0.00 | 0.00 | 672.00 | 0.00 | -715937301.5 | 58.98 | 0.00 | 0.00 |
Maximum of Months | 0.582138E+10 | -0.376163E+10 | 0.00 | 0.00 | 744.00 | 0.00 | -642836009.2 | 58.99 | 0.00 | 0.00 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.50 | 0.48 | 01-JAN-07:49 | 10608.03 | 39.55 | 274.17 | 267.83 | 5719.64 | 35.01 | 235.50 | 259.67 |
February | 245.50 | 0.49 | 0.48 | 01-FEB-10:39 | 14167.50 | 39.31 | 241.00 | 264.33 | 2392.44 | 24.90 | 117.50 | 243.67 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-06:00 | 2839.00 | 19.18 | 18.33 | 327.33 | 1624.12 | 21.08 | 131.00 | 293.00 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 2130.57 | 18.95 | 8.33 | 340.67 | 1246.71 | 21.17 | 163.00 | 303.33 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-06:10 | 1901.51 | 19.05 | 0.83 | 393.00 | 1053.77 | 21.25 | 261.67 | 357.17 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-05:49 | 1543.19 | 18.56 | 0.00 | 392.33 | 927.84 | 20.84 | 187.17 | 352.50 |
July | 430.33 | 0.51 | 0.48 | 01-JUL-06:10 | 1732.54 | 18.69 | 2.83 | 396.00 | 985.19 | 20.91 | 236.67 | 357.50 |
August | 394.50 | 0.51 | 0.48 | 01-AUG-06:10 | 1864.30 | 18.43 | 4.67 | 371.33 | 1143.72 | 20.67 | 171.83 | 337.00 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:19 | 3030.28 | 20.24 | 39.50 | 333.00 | 1425.63 | 21.08 | 169.33 | 305.00 |
October | 262.67 | 0.49 | 0.48 | 01-OCT-06:40 | 13789.60 | 36.66 | 239.83 | 300.50 | 2004.95 | 21.67 | 123.83 | 277.33 |
November | 257.67 | 0.49 | 0.48 | 01-NOV-08:39 | 12101.16 | 39.11 | 250.50 | 264.67 | 3682.56 | 29.94 | 180.00 | 243.17 |
December | 251.17 | 0.49 | 0.48 | 01-DEC-07:40 | 9938.22 | 39.96 | 250.67 | 258.50 | 8039.11 | 40.64 | 248.33 | 248.00 |
Annual Sum or Average | 3902.00 | 0.50 | 5411.17 | 25.59 | 1330.67 | 3909.50 | 2235.50 | 24.13 | 2225.83 | 3577.33 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 1543.19 | 18.43 | 0.00 | 258.50 | 927.84 | 20.67 | 117.50 | 243.17 | |
Maximum of Months | 430.33 | 0.51 | 0.48 | 14167.50 | 39.96 | 274.17 | 396.00 | 8039.11 | 40.64 | 261.67 | 357.50 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.53 | 0.48 | 01-JAN-07:49 | 2470.79 | 21.00 | 82.67 | 235.00 | 1495.14 | 23.48 | 97.00 | 205.83 |
February | 245.50 | 0.50 | 0.48 | 01-FEB-10:39 | 3941.77 | 23.33 | 84.33 | 250.83 | 2348.44 | 23.86 | 73.00 | 206.17 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-06:49 | 3771.68 | 22.39 | 83.50 | 319.83 | 2112.10 | 23.24 | 77.33 | 281.17 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 4103.61 | 21.88 | 84.83 | 341.83 | 1828.33 | 22.74 | 58.67 | 303.33 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-05:40 | 3292.41 | 21.79 | 111.67 | 400.67 | 1795.85 | 23.03 | 88.00 | 367.50 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-04:00 | 3919.40 | 21.43 | 109.00 | 404.67 | 2258.66 | 23.52 | 92.17 | 376.17 |
July | 430.33 | 0.50 | 0.48 | 01-JUL-05:10 | 3526.81 | 21.64 | 116.33 | 406.67 | 1909.60 | 22.72 | 87.83 | 374.83 |
August | 394.50 | 0.51 | 0.48 | 01-AUG-05:40 | 4852.18 | 22.98 | 131.00 | 373.50 | 1938.65 | 22.15 | 70.00 | 340.00 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-05:49 | 3960.04 | 22.54 | 108.33 | 332.33 | 1557.02 | 21.78 | 67.17 | 308.83 |
October | 262.67 | 0.50 | 0.48 | 01-OCT-06:19 | 3651.12 | 22.94 | 79.83 | 290.33 | 2053.80 | 23.69 | 68.00 | 250.00 |
November | 257.67 | 0.52 | 0.48 | 01-NOV-08:39 | 2486.69 | 21.33 | 70.50 | 242.83 | 1298.53 | 21.79 | 81.00 | 201.67 |
December | 251.17 | 0.52 | 0.48 | 01-DEC-07:40 | 2621.82 | 23.62 | 91.83 | 233.00 | 1547.91 | 24.16 | 97.17 | 195.17 |
Annual Sum or Average | 3902.00 | 0.50 | 3612.72 | 22.18 | 1153.83 | 3831.50 | 1859.65 | 22.96 | 957.33 | 3410.67 | ||
Minimum of Months | 245.50 | 0.50 | 0.48 | 2470.79 | 21.00 | 70.50 | 233.00 | 1298.53 | 21.78 | 58.67 | 195.17 | |
Maximum of Months | 430.33 | 0.53 | 0.48 | 4852.18 | 23.62 | 131.00 | 406.67 | 2348.44 | 24.16 | 97.17 | 376.17 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.55 | 0.48 | 01-JAN-08:00 | 561.88 | 14.46 | 0.00 | 219.17 | 375.14 | 17.24 | 0.00 | 156.50 |
February | 245.50 | 0.51 | 0.48 | 01-FEB-10:39 | 669.75 | 16.01 | 0.00 | 241.33 | 462.42 | 18.71 | 1.50 | 176.17 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-07:19 | 869.31 | 17.35 | 0.00 | 315.67 | 564.64 | 19.73 | 10.83 | 261.33 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 1160.94 | 18.58 | 0.00 | 345.67 | 690.29 | 20.73 | 78.33 | 302.17 |
May | 415.33 | 0.49 | 0.48 | 01-MAY-05:00 | 1410.42 | 19.27 | 4.50 | 408.67 | 785.99 | 21.47 | 204.00 | 381.00 |
June | 421.50 | 0.49 | 0.48 | 01-JUN-04:00 | 1542.23 | 21.90 | 76.17 | 418.17 | 863.67 | 24.04 | 255.17 | 404.83 |
July | 430.33 | 0.49 | 0.48 | 01-JUL-05:30 | 1453.34 | 20.28 | 35.67 | 420.00 | 805.96 | 22.46 | 236.83 | 393.50 |
August | 394.50 | 0.50 | 0.48 | 01-AUG-05:00 | 1130.92 | 18.46 | 2.83 | 380.00 | 701.28 | 20.64 | 113.83 | 347.00 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:19 | 952.33 | 17.85 | 0.00 | 330.83 | 602.78 | 20.13 | 42.83 | 290.33 |
October | 262.67 | 0.51 | 0.48 | 01-OCT-06:00 | 812.11 | 17.11 | 0.00 | 281.33 | 547.99 | 19.64 | 1.33 | 218.67 |
November | 257.67 | 0.53 | 0.48 | 01-NOV-08:50 | 630.78 | 15.48 | 0.00 | 229.50 | 429.70 | 18.22 | 0.33 | 168.67 |
December | 251.17 | 0.53 | 0.48 | 01-DEC-08:30 | 580.44 | 15.08 | 0.00 | 217.83 | 385.47 | 17.88 | 0.00 | 151.17 |
Annual Sum or Average | 3902.00 | 0.51 | 1047.62 | 18.05 | 119.17 | 3808.17 | 632.52 | 20.42 | 945.00 | 3251.33 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 561.88 | 14.46 | 0.00 | 217.83 | 375.14 | 17.24 | 0.00 | 151.17 | |
Maximum of Months | 430.33 | 0.55 | 0.48 | 1542.23 | 21.90 | 76.17 | 420.00 | 863.67 | 24.04 | 255.17 | 404.83 |
Report: DaylightingReportMonthly
For: PERIMETER_BOT_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.51 | 0.48 | 01-JAN-08:00 | 2956.45 | 24.16 | 108.67 | 252.17 | 1770.26 | 24.45 | 104.33 | 219.00 |
February | 245.50 | 0.49 | 0.48 | 01-FEB-10:39 | 3024.31 | 21.70 | 68.50 | 255.83 | 1733.33 | 23.94 | 73.67 | 214.17 |
March | 296.17 | 0.49 | 0.48 | 01-MAR-07:30 | 3562.68 | 22.98 | 99.33 | 328.50 | 2025.92 | 23.79 | 91.17 | 294.50 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 3330.95 | 21.52 | 85.33 | 347.50 | 1513.87 | 21.47 | 39.33 | 312.50 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-06:30 | 2880.74 | 18.33 | 53.17 | 398.50 | 1519.72 | 19.14 | 6.50 | 367.50 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-05:49 | 3421.95 | 15.28 | 1.83 | 403.33 | 1934.97 | 18.78 | 1.00 | 378.33 |
July | 430.33 | 0.50 | 0.48 | 01-JUL-06:10 | 2885.83 | 17.92 | 54.83 | 405.33 | 1579.80 | 18.93 | 7.50 | 376.17 |
August | 394.50 | 0.50 | 0.48 | 01-AUG-06:19 | 2994.80 | 17.88 | 53.67 | 380.67 | 1706.67 | 18.89 | 8.33 | 357.50 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:40 | 3332.56 | 22.34 | 109.83 | 334.50 | 1810.81 | 23.37 | 98.67 | 310.00 |
October | 262.67 | 0.50 | 0.48 | 01-OCT-06:00 | 4290.26 | 23.95 | 93.83 | 295.83 | 1695.50 | 23.65 | 66.50 | 260.00 |
November | 257.67 | 0.50 | 0.48 | 01-NOV-08:50 | 2991.04 | 24.46 | 96.50 | 252.67 | 1714.95 | 25.00 | 99.83 | 214.50 |
December | 251.17 | 0.51 | 0.48 | 01-DEC-08:30 | 2355.03 | 22.36 | 80.67 | 240.67 | 1422.42 | 24.74 | 93.83 | 212.83 |
Annual Sum or Average | 3902.00 | 0.50 | 3161.00 | 20.54 | 906.17 | 3895.50 | 1704.14 | 21.70 | 690.67 | 3517.00 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 2355.03 | 15.28 | 1.83 | 240.67 | 1422.42 | 18.78 | 1.00 | 212.83 | |
Maximum of Months | 430.33 | 0.51 | 0.48 | 4290.26 | 24.46 | 109.83 | 405.33 | 2025.92 | 25.00 | 104.33 | 378.33 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.50 | 0.48 | 01-JAN-07:49 | 10373.60 | 39.34 | 274.17 | 267.83 | 5523.90 | 33.85 | 205.33 | 259.00 |
February | 245.50 | 0.49 | 0.48 | 01-FEB-10:39 | 13943.54 | 39.05 | 241.00 | 263.00 | 2197.93 | 22.23 | 69.67 | 240.83 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-06:00 | 2723.10 | 15.35 | 10.33 | 327.83 | 1497.05 | 18.54 | 19.00 | 289.67 |
April | 296.67 | 0.51 | 0.48 | 03-APR-09:39 | 2026.45 | 15.27 | 0.00 | 339.00 | 1171.96 | 18.80 | 16.83 | 298.67 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-06:10 | 1823.21 | 15.36 | 0.00 | 391.50 | 1003.21 | 18.85 | 3.50 | 354.17 |
June | 421.50 | 0.51 | 0.48 | 01-JUN-05:49 | 1481.48 | 15.08 | 0.00 | 390.00 | 889.14 | 18.67 | 0.00 | 348.83 |
July | 430.33 | 0.51 | 0.48 | 01-JUL-06:10 | 1662.14 | 15.06 | 0.00 | 394.17 | 940.20 | 18.57 | 4.33 | 354.67 |
August | 394.50 | 0.51 | 0.48 | 01-AUG-06:10 | 1773.32 | 14.85 | 0.00 | 369.00 | 1078.52 | 18.41 | 20.00 | 333.83 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:19 | 2900.87 | 16.73 | 29.50 | 331.50 | 1326.52 | 18.58 | 15.33 | 302.33 |
October | 262.67 | 0.49 | 0.48 | 01-OCT-06:40 | 13588.53 | 36.18 | 239.67 | 300.00 | 1839.24 | 18.86 | 21.67 | 273.67 |
November | 257.67 | 0.49 | 0.48 | 01-NOV-08:39 | 11850.67 | 38.57 | 248.50 | 262.83 | 3481.37 | 27.91 | 131.83 | 240.83 |
December | 251.17 | 0.49 | 0.48 | 01-DEC-07:40 | 9577.86 | 37.58 | 233.50 | 254.33 | 7837.92 | 40.39 | 247.17 | 246.33 |
Annual Sum or Average | 3902.00 | 0.50 | 5266.78 | 22.92 | 1276.67 | 3891.00 | 2126.57 | 21.96 | 754.67 | 3542.83 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 1481.48 | 14.85 | 0.00 | 254.33 | 889.14 | 18.41 | 0.00 | 240.83 | |
Maximum of Months | 430.33 | 0.51 | 0.48 | 13943.54 | 39.34 | 274.17 | 394.17 | 7837.92 | 40.39 | 247.17 | 354.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.53 | 0.48 | 01-JAN-07:49 | 2406.25 | 20.52 | 82.67 | 233.67 | 1442.05 | 23.27 | 94.00 | 203.33 |
February | 245.50 | 0.50 | 0.48 | 01-FEB-10:39 | 3857.75 | 22.86 | 84.33 | 249.50 | 2277.68 | 23.66 | 70.67 | 204.50 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-06:49 | 3506.00 | 20.27 | 68.83 | 315.67 | 2031.95 | 23.04 | 72.00 | 279.17 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 3997.26 | 21.42 | 84.83 | 340.83 | 1745.70 | 22.55 | 54.50 | 298.17 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-05:40 | 3194.45 | 21.34 | 111.67 | 399.33 | 1723.71 | 22.84 | 86.17 | 364.67 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-04:00 | 3811.40 | 20.96 | 109.00 | 402.50 | 2149.97 | 22.57 | 79.83 | 373.50 |
July | 430.33 | 0.50 | 0.48 | 01-JUL-05:10 | 3417.29 | 21.06 | 114.50 | 404.50 | 1832.86 | 22.56 | 86.67 | 372.17 |
August | 394.50 | 0.51 | 0.48 | 01-AUG-05:40 | 4657.50 | 21.37 | 116.50 | 368.83 | 1849.40 | 21.98 | 69.83 | 337.50 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-05:49 | 3866.36 | 22.08 | 108.33 | 330.33 | 1479.41 | 21.59 | 61.00 | 307.00 |
October | 262.67 | 0.50 | 0.48 | 01-OCT-06:19 | 3556.48 | 22.47 | 79.83 | 289.00 | 1974.79 | 23.48 | 63.50 | 244.50 |
November | 257.67 | 0.52 | 0.48 | 01-NOV-08:39 | 2392.56 | 20.69 | 69.50 | 239.67 | 1238.95 | 21.57 | 76.83 | 200.33 |
December | 251.17 | 0.52 | 0.48 | 01-DEC-07:49 | 2406.15 | 21.34 | 78.00 | 228.33 | 1495.91 | 23.95 | 93.50 | 192.17 |
Annual Sum or Average | 3902.00 | 0.51 | 3485.78 | 21.33 | 1108.00 | 3802.17 | 1782.53 | 22.69 | 908.50 | 3377.00 | ||
Minimum of Months | 245.50 | 0.50 | 0.48 | 2392.56 | 20.27 | 68.83 | 228.33 | 1238.95 | 21.57 | 54.50 | 192.17 | |
Maximum of Months | 430.33 | 0.53 | 0.48 | 4657.50 | 22.86 | 116.50 | 404.50 | 2277.68 | 23.95 | 94.00 | 373.50 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.55 | 0.48 | 01-JAN-08:00 | 541.66 | 10.86 | 0.00 | 214.67 | 365.10 | 14.80 | 0.00 | 150.67 |
February | 245.50 | 0.51 | 0.48 | 01-FEB-10:39 | 647.35 | 12.57 | 0.00 | 239.00 | 451.84 | 16.51 | 0.00 | 172.00 |
March | 296.17 | 0.51 | 0.48 | 01-MAR-07:30 | 840.34 | 14.11 | 0.00 | 313.67 | 550.13 | 17.76 | 0.00 | 253.00 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 1121.65 | 15.32 | 0.00 | 344.17 | 669.16 | 18.82 | 9.50 | 295.67 |
May | 415.33 | 0.49 | 0.48 | 01-MAY-05:00 | 1361.02 | 15.67 | 0.00 | 406.67 | 758.51 | 19.31 | 20.50 | 377.00 |
June | 421.50 | 0.49 | 0.48 | 01-JUN-04:00 | 1460.28 | 15.87 | 0.00 | 416.33 | 834.75 | 22.29 | 110.17 | 402.67 |
July | 430.33 | 0.49 | 0.48 | 01-JUL-05:30 | 1396.28 | 15.58 | 0.00 | 416.50 | 777.93 | 20.45 | 61.67 | 391.83 |
August | 394.50 | 0.50 | 0.48 | 01-AUG-05:00 | 1118.37 | 15.17 | 0.00 | 380.83 | 681.46 | 18.77 | 22.17 | 344.00 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:30 | 919.91 | 14.63 | 0.00 | 327.67 | 586.01 | 18.22 | 0.00 | 286.67 |
October | 262.67 | 0.51 | 0.48 | 01-OCT-06:00 | 783.29 | 13.87 | 0.00 | 278.50 | 533.83 | 17.63 | 0.00 | 212.67 |
November | 257.67 | 0.53 | 0.48 | 01-NOV-08:50 | 607.60 | 11.97 | 0.00 | 225.83 | 418.32 | 15.90 | 0.00 | 164.83 |
December | 251.17 | 0.54 | 0.48 | 01-DEC-08:30 | 557.96 | 11.47 | 0.00 | 215.00 | 374.08 | 15.43 | 0.00 | 144.67 |
Annual Sum or Average | 3902.00 | 0.51 | 1010.06 | 14.22 | 0.00 | 3778.83 | 613.33 | 18.37 | 224.00 | 3195.67 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 541.66 | 10.86 | 0.00 | 214.67 | 365.10 | 14.80 | 0.00 | 144.67 | |
Maximum of Months | 430.33 | 0.55 | 0.48 | 1460.28 | 15.87 | 0.00 | 416.50 | 834.75 | 22.29 | 110.17 | 402.67 |
Report: DaylightingReportMonthly
For: PERIMETER_MID_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.52 | 0.48 | 01-JAN-08:00 | 2891.23 | 23.80 | 108.67 | 250.00 | 1715.82 | 24.36 | 104.00 | 215.67 |
February | 245.50 | 0.49 | 0.48 | 01-FEB-10:39 | 2937.24 | 21.28 | 68.50 | 254.17 | 1661.33 | 23.84 | 72.83 | 210.50 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-07:30 | 3476.67 | 22.57 | 99.33 | 326.67 | 1955.01 | 23.67 | 88.33 | 289.50 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 3244.53 | 21.08 | 85.33 | 344.83 | 1447.07 | 21.31 | 38.83 | 308.33 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-06:30 | 2792.87 | 17.83 | 53.17 | 397.00 | 1454.50 | 18.96 | 4.67 | 364.33 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-05:00 | 3322.49 | 14.75 | 1.83 | 401.17 | 1841.17 | 18.60 | 1.00 | 374.83 |
July | 430.33 | 0.50 | 0.48 | 01-JUL-06:10 | 2800.80 | 17.42 | 54.83 | 403.83 | 1517.12 | 18.74 | 5.50 | 374.67 |
August | 394.50 | 0.50 | 0.48 | 01-AUG-06:19 | 2908.59 | 17.39 | 53.67 | 379.67 | 1637.99 | 18.72 | 7.83 | 354.33 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:40 | 3251.92 | 21.91 | 109.83 | 332.17 | 1739.44 | 23.04 | 94.50 | 306.00 |
October | 262.67 | 0.50 | 0.48 | 01-OCT-06:00 | 4193.72 | 23.45 | 92.83 | 294.00 | 1554.14 | 22.47 | 57.00 | 252.83 |
November | 257.67 | 0.50 | 0.48 | 01-NOV-08:50 | 2755.46 | 21.58 | 77.17 | 248.83 | 1654.72 | 24.91 | 99.17 | 212.50 |
December | 251.17 | 0.51 | 0.48 | 01-DEC-08:30 | 2289.34 | 21.97 | 80.67 | 239.67 | 1368.88 | 24.66 | 92.50 | 208.83 |
Annual Sum or Average | 3902.00 | 0.50 | 3066.01 | 19.92 | 885.83 | 3872.00 | 1630.95 | 21.47 | 666.17 | 3472.33 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 2289.34 | 14.75 | 1.83 | 239.67 | 1368.88 | 18.60 | 1.00 | 208.83 | |
Maximum of Months | 430.33 | 0.52 | 0.48 | 4193.72 | 23.80 | 109.83 | 403.83 | 1955.01 | 24.91 | 104.00 | 374.83 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_1_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.50 | 0.48 | 01-JAN-07:49 | 10373.60 | 39.34 | 274.17 | 267.83 | 5523.82 | 33.85 | 205.33 | 259.00 |
February | 245.50 | 0.49 | 0.48 | 01-FEB-10:39 | 13943.51 | 39.05 | 241.00 | 263.00 | 2197.85 | 22.23 | 69.67 | 240.83 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-06:00 | 2723.01 | 15.35 | 10.33 | 327.83 | 1496.97 | 18.54 | 19.00 | 289.67 |
April | 296.67 | 0.51 | 0.48 | 03-APR-09:39 | 2026.34 | 15.28 | 0.00 | 339.00 | 1171.87 | 18.80 | 16.83 | 298.67 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-06:10 | 1823.10 | 15.36 | 0.00 | 391.50 | 1003.13 | 18.85 | 3.50 | 354.17 |
June | 421.50 | 0.51 | 0.48 | 01-JUN-05:49 | 1481.42 | 15.08 | 0.00 | 390.00 | 889.08 | 18.67 | 0.17 | 348.67 |
July | 430.33 | 0.51 | 0.48 | 01-JUL-06:10 | 1662.05 | 15.06 | 0.00 | 394.17 | 940.13 | 18.57 | 4.33 | 354.67 |
August | 394.50 | 0.51 | 0.48 | 01-AUG-06:10 | 1773.24 | 14.85 | 0.00 | 369.00 | 1078.45 | 18.41 | 20.00 | 333.67 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:19 | 2900.76 | 16.73 | 29.50 | 331.50 | 1326.43 | 18.58 | 15.33 | 302.33 |
October | 262.67 | 0.49 | 0.48 | 01-OCT-06:40 | 13588.46 | 36.18 | 239.67 | 300.00 | 1839.15 | 18.86 | 21.67 | 273.67 |
November | 257.67 | 0.49 | 0.48 | 01-NOV-08:39 | 11850.67 | 38.57 | 248.50 | 262.83 | 3481.27 | 27.91 | 131.83 | 240.83 |
December | 251.17 | 0.49 | 0.48 | 01-DEC-07:40 | 9577.89 | 37.58 | 233.50 | 254.33 | 7837.83 | 40.39 | 247.17 | 246.33 |
Annual Sum or Average | 3902.00 | 0.50 | 5266.71 | 22.92 | 1276.67 | 3891.00 | 2126.49 | 21.96 | 754.83 | 3542.50 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 1481.42 | 14.85 | 0.00 | 254.33 | 889.08 | 18.41 | 0.17 | 240.83 | |
Maximum of Months | 430.33 | 0.51 | 0.48 | 13943.51 | 39.34 | 274.17 | 394.17 | 7837.83 | 40.39 | 247.17 | 354.67 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_2_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.53 | 0.48 | 01-JAN-07:49 | 2406.24 | 20.52 | 82.67 | 233.67 | 1442.02 | 23.27 | 94.00 | 203.33 |
February | 245.50 | 0.50 | 0.48 | 01-FEB-10:39 | 3857.75 | 22.86 | 84.33 | 249.50 | 2277.64 | 23.66 | 70.83 | 204.50 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-06:49 | 3505.98 | 20.27 | 68.83 | 315.67 | 2031.89 | 23.04 | 72.00 | 279.17 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 3997.21 | 21.42 | 84.83 | 340.83 | 1745.63 | 22.56 | 54.50 | 298.17 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-05:40 | 3194.38 | 21.34 | 111.67 | 399.33 | 1723.62 | 22.84 | 86.33 | 364.67 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-04:00 | 3811.36 | 20.96 | 109.00 | 402.50 | 2149.89 | 22.57 | 79.83 | 373.50 |
July | 430.33 | 0.50 | 0.48 | 01-JUL-05:10 | 3417.23 | 21.06 | 114.50 | 404.50 | 1832.78 | 22.56 | 86.67 | 372.17 |
August | 394.50 | 0.51 | 0.48 | 01-AUG-05:40 | 4657.46 | 21.37 | 116.50 | 368.83 | 1849.33 | 21.98 | 69.83 | 337.50 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-05:49 | 3866.32 | 22.08 | 108.33 | 330.33 | 1479.35 | 21.59 | 61.00 | 307.00 |
October | 262.67 | 0.50 | 0.48 | 01-OCT-06:19 | 3556.47 | 22.47 | 79.83 | 289.00 | 1974.74 | 23.48 | 63.50 | 244.50 |
November | 257.67 | 0.52 | 0.48 | 01-NOV-08:39 | 2392.56 | 20.70 | 69.50 | 239.67 | 1238.91 | 21.57 | 76.83 | 200.33 |
December | 251.17 | 0.52 | 0.48 | 01-DEC-07:49 | 2406.14 | 21.35 | 78.00 | 228.33 | 1495.88 | 23.95 | 93.50 | 192.17 |
Annual Sum or Average | 3902.00 | 0.51 | 3485.75 | 21.34 | 1108.00 | 3802.17 | 1782.47 | 22.69 | 908.83 | 3377.00 | ||
Minimum of Months | 245.50 | 0.50 | 0.48 | 2392.56 | 20.27 | 68.83 | 228.33 | 1238.91 | 21.57 | 54.50 | 192.17 | |
Maximum of Months | 430.33 | 0.53 | 0.48 | 4657.46 | 22.86 | 116.50 | 404.50 | 2277.64 | 23.95 | 94.00 | 373.50 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_3_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.55 | 0.48 | 01-JAN-08:00 | 541.66 | 10.86 | 0.00 | 214.67 | 365.08 | 14.80 | 0.00 | 150.67 |
February | 245.50 | 0.51 | 0.48 | 01-FEB-10:39 | 647.35 | 12.58 | 0.00 | 239.00 | 451.82 | 16.51 | 0.00 | 172.00 |
March | 296.17 | 0.51 | 0.48 | 01-MAR-07:30 | 840.33 | 14.11 | 0.00 | 313.67 | 550.10 | 17.76 | 0.00 | 253.00 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 1121.62 | 15.32 | 0.00 | 344.17 | 669.12 | 18.82 | 9.50 | 295.67 |
May | 415.33 | 0.49 | 0.48 | 01-MAY-05:00 | 1360.97 | 15.67 | 0.00 | 406.67 | 758.46 | 19.31 | 20.50 | 377.00 |
June | 421.50 | 0.49 | 0.48 | 01-JUN-04:00 | 1460.24 | 15.87 | 0.00 | 416.33 | 834.70 | 22.29 | 110.17 | 402.67 |
July | 430.33 | 0.49 | 0.48 | 01-JUL-05:30 | 1396.23 | 15.58 | 0.00 | 416.50 | 777.88 | 20.45 | 61.67 | 391.83 |
August | 394.50 | 0.50 | 0.48 | 01-AUG-05:00 | 1118.35 | 15.18 | 0.00 | 380.83 | 681.42 | 18.77 | 22.17 | 344.00 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:30 | 919.89 | 14.64 | 0.00 | 327.67 | 585.98 | 18.22 | 0.00 | 286.67 |
October | 262.67 | 0.51 | 0.48 | 01-OCT-06:00 | 783.29 | 13.87 | 0.00 | 278.50 | 533.80 | 17.63 | 0.00 | 212.67 |
November | 257.67 | 0.53 | 0.48 | 01-NOV-08:50 | 607.60 | 11.97 | 0.00 | 225.83 | 418.30 | 15.90 | 0.00 | 164.83 |
December | 251.17 | 0.54 | 0.48 | 01-DEC-08:30 | 557.96 | 11.47 | 0.00 | 215.00 | 374.06 | 15.43 | 0.00 | 144.67 |
Annual Sum or Average | 3902.00 | 0.51 | 1010.04 | 14.22 | 0.00 | 3778.83 | 613.30 | 18.37 | 224.00 | 3195.67 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 541.66 | 10.86 | 0.00 | 214.67 | 365.08 | 14.80 | 0.00 | 144.67 | |
Maximum of Months | 430.33 | 0.55 | 0.48 | 1460.24 | 15.87 | 0.00 | 416.50 | 834.70 | 22.29 | 110.17 | 402.67 |
Report: DaylightingReportMonthly
For: PERIMETER_TOP_ZN_4_DAYLCTRL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] | DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] | DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} | DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] | DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] | DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] | |
January | 276.50 | 0.52 | 0.48 | 01-JAN-08:00 | 2891.22 | 23.80 | 108.67 | 250.00 | 1715.78 | 24.36 | 104.00 | 215.67 |
February | 245.50 | 0.49 | 0.48 | 01-FEB-10:39 | 2937.24 | 21.28 | 68.50 | 254.17 | 1661.29 | 23.84 | 72.83 | 210.50 |
March | 296.17 | 0.50 | 0.48 | 01-MAR-07:30 | 3476.65 | 22.57 | 99.33 | 326.67 | 1954.95 | 23.67 | 88.50 | 289.50 |
April | 296.67 | 0.50 | 0.48 | 03-APR-09:39 | 3244.47 | 21.08 | 85.33 | 344.83 | 1447.00 | 21.31 | 38.83 | 308.33 |
May | 415.33 | 0.50 | 0.48 | 01-MAY-06:30 | 2792.78 | 17.84 | 53.17 | 397.00 | 1454.41 | 18.96 | 4.67 | 364.33 |
June | 421.50 | 0.50 | 0.48 | 01-JUN-05:00 | 3322.44 | 14.75 | 1.83 | 401.17 | 1841.10 | 18.60 | 1.00 | 374.83 |
July | 430.33 | 0.50 | 0.48 | 01-JUL-06:10 | 2800.73 | 17.43 | 54.83 | 403.83 | 1517.04 | 18.74 | 5.67 | 374.67 |
August | 394.50 | 0.50 | 0.48 | 01-AUG-06:19 | 2908.56 | 17.40 | 53.67 | 379.67 | 1637.93 | 18.72 | 7.83 | 354.33 |
September | 354.00 | 0.50 | 0.48 | 01-SEP-06:40 | 3251.88 | 21.92 | 109.83 | 332.17 | 1739.37 | 23.04 | 94.50 | 306.00 |
October | 262.67 | 0.50 | 0.48 | 01-OCT-06:00 | 4193.72 | 23.46 | 92.83 | 294.00 | 1554.09 | 22.47 | 57.00 | 252.83 |
November | 257.67 | 0.50 | 0.48 | 01-NOV-08:50 | 2755.46 | 21.58 | 77.17 | 248.83 | 1654.68 | 24.91 | 99.17 | 212.50 |
December | 251.17 | 0.51 | 0.48 | 01-DEC-08:30 | 2289.33 | 21.97 | 80.67 | 239.67 | 1368.84 | 24.66 | 92.50 | 208.83 |
Annual Sum or Average | 3902.00 | 0.50 | 3065.97 | 19.92 | 885.83 | 3872.00 | 1630.89 | 21.47 | 666.50 | 3472.33 | ||
Minimum of Months | 245.50 | 0.49 | 0.48 | 2289.33 | 14.75 | 1.83 | 239.67 | 1368.84 | 18.60 | 1.00 | 208.83 | |
Maximum of Months | 430.33 | 0.52 | 0.48 | 4193.72 | 23.80 | 109.83 | 403.83 | 1954.95 | 24.91 | 104.00 | 374.83 |
Report: CoilReportMonthly
For: CORE_BOTTOM VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 01-APR-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 3564915.67 | 17306.43 | 26-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 3564915.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 3564915.67 | 17306.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.232719E+10 | 11999.24 | 05-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.277817E+10 | 11149.38 | 08-FEB-18:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.244392E+10 | 11215.23 | 17-MAR-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.180574E+10 | 11205.17 | 25-APR-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.603633E+09 | 11394.76 | 11-MAY-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 11417023.65 | 7737.17 | 09-JUN-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 3281793.21 | 3275.09 | 03-JUL-06:07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 1228554.13 | 3426.11 | 23-AUG-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.106243E+09 | 11278.45 | 22-SEP-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.171295E+10 | 11299.88 | 13-OCT-06:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.183250E+10 | 11271.89 | 10-NOV-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.319330E+10 | 13469.65 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.168196E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 1228554.13 | 3275.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.319330E+10 | 13469.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.658925E+09 | 9332.44 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.892565E+09 | 9332.44 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.454466E+09 | 9332.44 | 02-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.209402E+09 | 9332.44 | 03-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 2823192.42 | 5124.87 | 01-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.206578E+09 | 9332.44 | 30-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.294912E+09 | 9332.44 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.104465E+10 | 9332.44 | 07-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.376432E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.104465E+10 | 9332.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.184660E+10 | 8598.07 | 05-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.214170E+10 | 7993.16 | 06-FEB-05:13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.112070E+10 | 7997.67 | 24-MAR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.535836E+09 | 8027.98 | 25-APR-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 22192784.62 | 7962.28 | 01-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.343912E+09 | 7941.34 | 25-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.696200E+09 | 8007.58 | 28-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.230674E+10 | 9649.92 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.901389E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.230674E+10 | 9649.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_BOT_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.716873E+09 | 9332.35 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.915076E+09 | 9332.35 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.505860E+09 | 9332.35 | 02-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.252652E+09 | 9332.35 | 03-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 9240729.19 | 7082.06 | 02-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.209264E+09 | 9332.35 | 30-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.286539E+09 | 9332.35 | 01-NOV-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.109486E+10 | 9332.35 | 07-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.399037E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.109486E+10 | 9332.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_MID VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.156328E+09 | 23552.52 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.485777E+09 | 23552.52 | 06-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.182462E+09 | 23552.52 | 06-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.101357E+09 | 23552.52 | 03-APR-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 60186514.04 | 23552.52 | 30-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 46184040.13 | 23552.52 | 01-NOV-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.686933E+09 | 23552.52 | 11-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.171923E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.686933E+09 | 23552.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.582800E+09 | 12810.93 | 02-JAN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.962449E+09 | 12781.73 | 07-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.560002E+09 | 12719.70 | 24-MAR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.355679E+09 | 12763.53 | 17-APR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 16376314.86 | 11429.59 | 02-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 1121604.36 | 2525.52 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.487539E+09 | 12712.35 | 31-OCT-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.470671E+09 | 12798.96 | 29-NOV-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132877E+10 | 13548.04 | 19-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.476540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.132877E+10 | 13548.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.618466E+09 | 9760.68 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.795208E+09 | 9760.68 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.374180E+09 | 9760.68 | 02-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.206812E+09 | 9760.68 | 03-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 3202600.28 | 6100.29 | 01-MAY-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 187612.04 | 1250.75 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.346062E+09 | 9760.68 | 23-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.452743E+09 | 9760.68 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.132580E+10 | 9760.68 | 06-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.412266E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.132580E+10 | 9760.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.137381E+10 | 9381.75 | 05-JAN-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161537E+10 | 9018.92 | 14-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.761566E+09 | 9053.06 | 20-MAR-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.417411E+09 | 9031.68 | 04-APR-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 14088487.01 | 9004.23 | 01-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 1543722.65 | 3026.56 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.533078E+09 | 9011.97 | 28-OCT-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.896511E+09 | 9032.58 | 02-NOV-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.255035E+10 | 10330.22 | 23-DEC-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.816373E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.255035E+10 | 10330.22 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_MID_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.691050E+09 | 9760.58 | 02-JAN-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.870703E+09 | 9760.58 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.431891E+09 | 9760.58 | 02-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.254146E+09 | 9760.58 | 03-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 10618077.97 | 7220.59 | 02-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 1581852.52 | 2854.54 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.347335E+09 | 9760.58 | 23-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.484383E+09 | 9760.58 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.141190E+10 | 9760.58 | 06-DEC-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.450361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.141190E+10 | 9760.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: CORE_TOP VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.180758E+10 | 32520.24 | 02-JAN-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.229204E+10 | 32492.12 | 14-FEB-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.112472E+10 | 32534.68 | 02-MAR-07:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.862811E+09 | 32497.69 | 17-APR-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 41300005.44 | 32312.41 | 01-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.814421E+09 | 32425.61 | 30-OCT-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.109196E+10 | 32462.48 | 01-NOV-05:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.337893E+10 | 33235.28 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.114138E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.337893E+10 | 33235.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_1 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.152195E+10 | 14250.45 | 30-JAN-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.208412E+10 | 14204.45 | 01-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.148773E+10 | 14247.72 | 25-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.985071E+09 | 14202.97 | 03-APR-04:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 78959494.83 | 14157.71 | 01-MAY-05:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 22025234.09 | 10886.36 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.116404E+10 | 14238.65 | 25-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.128910E+10 | 14222.55 | 24-NOV-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.304447E+10 | 15639.67 | 20-DEC-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.116775E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.304447E+10 | 15639.67 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_2 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.143659E+10 | 11686.20 | 19-JAN-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.166983E+10 | 11722.42 | 25-FEB-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.988814E+09 | 11680.78 | 20-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.583083E+09 | 11708.23 | 06-APR-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 25162360.48 | 11706.15 | 03-MAY-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 10863777.50 | 6760.98 | 22-SEP-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.822960E+09 | 11741.53 | 28-OCT-05:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.111812E+10 | 11727.34 | 24-NOV-05:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.275733E+10 | 12032.80 | 23-DEC-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.941276E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.275733E+10 | 12032.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_3 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.301918E+10 | 11082.83 | 05-JAN-07:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.333055E+10 | 10436.65 | 21-FEB-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.192267E+10 | 10454.33 | 25-MAR-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.112750E+10 | 10423.15 | 24-APR-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 75982424.42 | 10398.92 | 03-MAY-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 25606973.14 | 10393.01 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.132947E+10 | 10447.67 | 25-OCT-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.221590E+10 | 10456.68 | 16-NOV-06:12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.511621E+10 | 11829.73 | 22-DEC-08:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.181631E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.511621E+10 | 11829.73 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PERIMETER_TOP_ZN_4 VAV BOX REHEAT COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.162100E+10 | 12424.44 | 02-JAN-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.186173E+10 | 12424.44 | 01-FEB-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.113739E+10 | 12424.44 | 01-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.692762E+09 | 12424.44 | 03-APR-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 50762210.54 | 12424.44 | 01-MAY-05:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 17422691.04 | 7309.56 | 22-SEP-05:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.839432E+09 | 12424.44 | 23-OCT-05:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.124244E+10 | 12424.44 | 01-NOV-04:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.294960E+10 | 12424.44 | 01-DEC-06:11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.104125E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.294960E+10 | 12424.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT HEATING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.759826E+10 | 24025.31 | 05-JAN-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.746314E+10 | 22725.93 | 06-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.471466E+10 | 17572.43 | 02-MAR-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.273578E+10 | 19293.10 | 17-APR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.191426E+09 | 8547.69 | 02-MAY-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.124511E+09 | 9504.63 | 22-SEP-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.290989E+10 | 21008.23 | 30-OCT-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.549651E+10 | 22262.42 | 30-NOV-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.999452E+10 | 24025.31 | 19-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.412287E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.999452E+10 | 24025.31 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID HEATING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.804194E+10 | 25341.40 | 05-JAN-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.792558E+10 | 21860.05 | 02-FEB-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.539081E+10 | 18852.47 | 29-MAR-06:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.338463E+10 | 18772.88 | 03-APR-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.353218E+09 | 9039.22 | 02-MAY-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 50863.04 | 254.82 | 09-JUN-06:06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.239981E+09 | 9083.38 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.379941E+10 | 21338.79 | 30-OCT-06:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.636568E+10 | 22066.27 | 30-NOV-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.107788E+11 | 25341.40 | 19-DEC-07:01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.462802E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.107788E+11 | 25341.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP HEATING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [J] | HEATING COIL HEATING RATE {Maximum} [W] | HEATING COIL HEATING RATE {TIMESTAMP} | COOLING COIL TOTAL COOLING ENERGY [] | COOLING COIL SENSIBLE COOLING ENERGY [] | COOLING COIL TOTAL COOLING RATE [] | COOLING COIL SENSIBLE COOLING RATE [] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.877133E+10 | 24255.62 | 05-JAN-07:05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.864725E+10 | 23386.04 | 02-FEB-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.589882E+10 | 21984.30 | 04-MAR-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.368041E+10 | 16664.73 | 03-APR-07:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.457166E+09 | 9647.75 | 02-MAY-06:08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 1163005.08 | 1315.39 | 09-JUN-06:02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.302472E+09 | 13616.14 | 22-SEP-06:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.449068E+10 | 21244.03 | 30-OCT-07:03 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.699701E+10 | 23509.18 | 29-NOV-21:00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.118745E+11 | 24255.62 | 19-DEC-07:04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.511208E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
Maximum of Months | 0.118745E+11 | 24255.62 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_BOT COOLING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.319051E+10 | 0.317331E+10 | 28204.15 | 20-JAN-14:00 | 28204.15 | 0.00 |
February | 0.00 | 0.00 | 0.147274E+10 | 0.144797E+10 | 13725.43 | 24-FEB-13:06 | 13725.43 | 0.00 |
March | 0.00 | 0.00 | 0.375964E+10 | 0.375646E+10 | 39743.59 | 14-MAR-13:00 | 39743.59 | 0.00 |
April | 0.00 | 0.00 | 0.388969E+10 | 0.380335E+10 | 24644.08 | 20-APR-13:00 | 24644.08 | 0.00 |
May | 0.00 | 0.00 | 0.151114E+11 | 0.147506E+11 | 49370.51 | 17-MAY-13:00 | 49370.51 | 0.00 |
June | 0.00 | 0.00 | 0.538033E+11 | 0.512286E+11 | 78232.13 | 26-JUN-15:20 | 78232.13 | 0.00 |
July | 0.00 | 0.00 | 0.546444E+11 | 0.503393E+11 | 74143.50 | 17-JUL-12:20 | 74143.50 | 0.00 |
August | 0.00 | 0.00 | 0.541523E+11 | 0.513808E+11 | 72652.20 | 16-AUG-16:00 | 72652.20 | 0.00 |
September | 0.00 | 0.00 | 0.378275E+11 | 0.372261E+11 | 65704.03 | 12-SEP-16:00 | 65704.03 | 0.00 |
October | 0.00 | 0.00 | 0.110476E+11 | 0.109220E+11 | 55793.82 | 10-OCT-15:30 | 55793.82 | 0.00 |
November | 0.00 | 0.00 | 0.409568E+10 | 0.404137E+10 | 32318.63 | 07-NOV-15:00 | 32318.63 | 0.00 |
December | 0.00 | 0.00 | 0.188006E+10 | 0.187590E+10 | 23975.75 | 01-DEC-14:00 | 23975.75 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.244875E+12 | 0.233946E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.147274E+10 | 0.144797E+10 | 13725.43 | 13725.43 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.546444E+11 | 0.513808E+11 | 78232.13 | 78232.13 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_MID COOLING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.177146E+10 | 0.175852E+10 | 22763.19 | 24-JAN-15:05 | 22763.19 | 0.00 |
February | 0.00 | 0.00 | 0.118277E+10 | 0.116078E+10 | 18105.01 | 27-FEB-15:05 | 18105.01 | 0.00 |
March | 0.00 | 0.00 | 0.334064E+10 | 0.333969E+10 | 37904.88 | 13-MAR-16:00 | 37904.88 | 0.00 |
April | 0.00 | 0.00 | 0.261166E+10 | 0.257119E+10 | 24591.08 | 20-APR-13:00 | 24591.08 | 0.00 |
May | 0.00 | 0.00 | 0.131475E+11 | 0.127855E+11 | 48398.92 | 16-MAY-14:05 | 48398.92 | 0.00 |
June | 0.00 | 0.00 | 0.492687E+11 | 0.470208E+11 | 74663.43 | 26-JUN-15:20 | 74663.43 | 0.00 |
July | 0.00 | 0.00 | 0.499775E+11 | 0.462060E+11 | 71146.56 | 17-JUL-12:02 | 71146.56 | 0.00 |
August | 0.00 | 0.00 | 0.475703E+11 | 0.452045E+11 | 68947.42 | 16-AUG-15:00 | 68947.42 | 0.00 |
September | 0.00 | 0.00 | 0.314155E+11 | 0.309111E+11 | 61580.24 | 12-SEP-15:40 | 61580.24 | 0.00 |
October | 0.00 | 0.00 | 0.726465E+10 | 0.723746E+10 | 50755.73 | 11-OCT-14:05 | 50755.73 | 0.00 |
November | 0.00 | 0.00 | 0.245749E+10 | 0.243457E+10 | 30218.29 | 07-NOV-15:05 | 30218.29 | 0.00 |
December | 0.00 | 0.00 | 0.113793E+10 | 0.113429E+10 | 19405.92 | 01-DEC-14:00 | 19405.92 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.211146E+12 | 0.201764E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.113793E+10 | 0.113429E+10 | 18105.01 | 18105.01 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.499775E+11 | 0.470208E+11 | 74663.43 | 74663.43 | 0.00 |
Report: CoilReportMonthly
For: PACU_VAV_TOP COOLING COIL
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportHEATING COIL HEATING ENERGY [] | HEATING COIL HEATING RATE [] | COOLING COIL TOTAL COOLING ENERGY [J] | COOLING COIL SENSIBLE COOLING ENERGY [J] | COOLING COIL TOTAL COOLING RATE {Maximum} [W] | COOLING COIL TOTAL COOLING RATE {TIMESTAMP} | COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] | COOLING COIL WETTED AREA FRACTION [] | |
January | 0.00 | 0.00 | 0.964104E+09 | 0.947217E+09 | 20587.95 | 20-JAN-14:10 | 20587.95 | 0.00 |
February | 0.00 | 0.00 | 0.152123E+10 | 0.149390E+10 | 18648.27 | 17-FEB-15:10 | 18648.27 | 0.00 |
March | 0.00 | 0.00 | 0.350335E+10 | 0.349952E+10 | 39532.03 | 13-MAR-15:50 | 39532.03 | 0.00 |
April | 0.00 | 0.00 | 0.263576E+10 | 0.258250E+10 | 26740.65 | 20-APR-13:00 | 26740.65 | 0.00 |
May | 0.00 | 0.00 | 0.140827E+11 | 0.135851E+11 | 57213.70 | 31-MAY-15:20 | 57213.70 | 0.00 |
June | 0.00 | 0.00 | 0.540045E+11 | 0.515385E+11 | 86929.22 | 26-JUN-15:10 | 86929.22 | 0.00 |
July | 0.00 | 0.00 | 0.541330E+11 | 0.500894E+11 | 79355.62 | 17-JUL-14:00 | 79355.62 | 0.00 |
August | 0.00 | 0.00 | 0.516628E+11 | 0.491358E+11 | 81720.02 | 16-AUG-15:00 | 81720.02 | 0.00 |
September | 0.00 | 0.00 | 0.325314E+11 | 0.318575E+11 | 69370.39 | 12-SEP-15:40 | 69370.39 | 0.00 |
October | 0.00 | 0.00 | 0.621158E+10 | 0.616964E+10 | 55867.97 | 11-OCT-15:00 | 55867.97 | 0.00 |
November | 0.00 | 0.00 | 0.238830E+10 | 0.234885E+10 | 29314.05 | 07-NOV-14:40 | 29314.05 | 0.00 |
December | 0.00 | 0.00 | 0.100450E+10 | 0.996418E+09 | 18376.05 | 01-DEC-14:00 | 18376.05 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.224643E+12 | 0.214244E+12 | 0.00 | |||
Minimum of Months | 0.00 | 0.00 | 0.964104E+09 | 0.947217E+09 | 18376.05 | 18376.05 | 0.00 | |
Maximum of Months | 0.00 | 0.00 | 0.541330E+11 | 0.515385E+11 | 86929.22 | 86929.22 | 0.00 |
Report: PlantLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 1932.36 | 6772.53 | 31-JAN-12:06 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 1966.00 | 6808.02 | 14-FEB-12:10 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 2065.94 | 6782.91 | 01-MAR-12:09 |
April | 0.00 | 0.00 | 01-APR-00:10 | 1858.71 | 6566.17 | 03-APR-11:13 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 1828.15 | 6253.44 | 01-MAY-11:07 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 1772.44 | 5876.40 | 01-JUN-11:40 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 1557.74 | 5559.65 | 03-JUL-12:00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 1687.05 | 5420.64 | 31-AUG-11:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 1604.13 | 5581.19 | 29-SEP-11:40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 1675.14 | 5949.81 | 31-OCT-11:06 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 1796.76 | 6298.73 | 30-NOV-12:10 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 1815.35 | 6574.19 | 29-DEC-12:06 |
Annual Sum or Average | 0.00 | 1795.68 | ||||
Minimum of Months | 0.00 | 0.00 | 1557.74 | 5420.64 | ||
Maximum of Months | 0.00 | 0.00 | 2065.94 | 6808.02 |
Report: FanReportMonthly
For: PACU_VAV_BOT FAN
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.170505E+10 | 0.40 | 3756.50 | 24-JAN-16:20 | 1.04 |
February | 0.155918E+10 | 0.41 | 3270.08 | 27-FEB-15:30 | 0.96 |
March | 0.222426E+10 | 0.44 | 6429.06 | 15-MAR-16:00 | 1.43 |
April | 0.182898E+10 | 0.39 | 3679.07 | 21-APR-13:00 | 1.02 |
May | 0.313123E+10 | 0.45 | 6130.52 | 16-MAY-06:03 | 1.38 |
June | 0.674719E+10 | 0.69 | 12858.22 | 26-JUN-12:08 | 2.18 |
July | 0.640487E+10 | 0.65 | 12858.22 | 18-JUL-12:07 | 2.19 |
August | 0.671137E+10 | 0.67 | 11337.77 | 18-AUG-12:07 | 2.02 |
September | 0.534023E+10 | 0.60 | 12744.46 | 05-SEP-06:02 | 2.18 |
October | 0.289365E+10 | 0.45 | 6576.36 | 10-OCT-09:00 | 1.44 |
November | 0.202226E+10 | 0.41 | 4785.27 | 07-NOV-16:40 | 1.19 |
December | 0.162765E+10 | 0.40 | 2885.77 | 04-DEC-15:30 | 0.90 |
Annual Sum or Average | 0.421959E+11 | 0.50 | |||
Minimum of Months | 0.155918E+10 | 0.39 | 2885.77 | 0.90 | |
Maximum of Months | 0.674719E+10 | 0.69 | 12858.22 | 2.19 |
Report: FanReportMonthly
For: PACU_VAV_MID FAN
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.143213E+10 | 0.40 | 3048.85 | 02-JAN-06:01 | 0.98 |
February | 0.136837E+10 | 0.41 | 3048.85 | 07-FEB-06:02 | 0.98 |
March | 0.191795E+10 | 0.45 | 7070.20 | 15-MAR-16:00 | 1.62 |
April | 0.158527E+10 | 0.40 | 4401.88 | 21-APR-12:02 | 1.21 |
May | 0.282416E+10 | 0.47 | 6939.18 | 18-MAY-14:05 | 1.59 |
June | 0.620758E+10 | 0.69 | 11534.21 | 26-JUN-10:10 | 2.18 |
July | 0.587751E+10 | 0.65 | 11534.21 | 17-JUL-05:12 | 2.19 |
August | 0.593010E+10 | 0.66 | 11197.27 | 14-AUG-15:00 | 2.15 |
September | 0.428434E+10 | 0.56 | 11343.95 | 05-SEP-15:40 | 2.16 |
October | 0.210180E+10 | 0.43 | 7426.73 | 10-OCT-16:00 | 1.67 |
November | 0.153643E+10 | 0.41 | 4393.77 | 07-NOV-16:00 | 1.21 |
December | 0.142230E+10 | 0.42 | 3048.85 | 11-DEC-06:01 | 0.98 |
Annual Sum or Average | 0.364879E+11 | 0.50 | |||
Minimum of Months | 0.136837E+10 | 0.40 | 3048.85 | 0.98 | |
Maximum of Months | 0.620758E+10 | 0.69 | 11534.21 | 2.19 |
Report: FanReportMonthly
For: PACU_VAV_TOP FAN
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportFAN ELECTRICITY ENERGY [J] | FAN RISE IN AIR TEMPERATURE [deltaC] | FAN ELECTRICITY RATE {Maximum} [W] | FAN ELECTRICITY RATE {TIMESTAMP} | FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC] | |
January | 0.165777E+10 | 0.47 | 3002.95 | 02-JAN-05:11 | 0.89 |
February | 0.161357E+10 | 0.49 | 3002.95 | 01-FEB-06:01 | 0.89 |
March | 0.206979E+10 | 0.52 | 6618.10 | 15-MAR-15:50 | 1.42 |
April | 0.172822E+10 | 0.46 | 4555.36 | 21-APR-13:30 | 1.13 |
May | 0.266503E+10 | 0.47 | 6721.65 | 31-MAY-15:20 | 1.41 |
June | 0.596598E+10 | 0.64 | 12143.72 | 26-JUN-15:10 | 2.05 |
July | 0.555428E+10 | 0.60 | 11918.59 | 17-JUL-10:40 | 2.03 |
August | 0.559873E+10 | 0.61 | 11663.85 | 11-AUG-15:00 | 2.00 |
September | 0.382854E+10 | 0.53 | 9931.28 | 12-SEP-15:40 | 1.80 |
October | 0.203629E+10 | 0.46 | 7096.50 | 11-OCT-16:00 | 1.48 |
November | 0.160826E+10 | 0.45 | 3573.17 | 07-NOV-15:40 | 0.99 |
December | 0.178929E+10 | 0.52 | 3002.95 | 07-DEC-06:01 | 0.90 |
Annual Sum or Average | 0.361158E+11 | 0.52 | |||
Minimum of Months | 0.160826E+10 | 0.45 | 3002.95 | 0.89 | |
Maximum of Months | 0.596598E+10 | 0.64 | 12143.72 | 2.05 |
Report: PumpReportMonthly
For: SWHSYS1 PUMP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPUMP ELECTRICITY ENERGY [J] | PUMP FLUID HEAT GAIN ENERGY [J] | PUMP ELECTRICITY RATE {Maximum} [W] | PUMP ELECTRICITY RATE {TIMESTAMP} | PUMP SHAFT POWER {AT MAX/MIN} [W] | PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] | PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] | PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s] | |
January | 12379742.02 | 3713922.60 | 6.85 | 01-JAN-06:05 | 2.06 | 2.06 | 56.68 | 0.05 |
February | 11196021.66 | 3358806.50 | 6.85 | 01-FEB-06:01 | 2.06 | 2.06 | 56.68 | 0.05 |
March | 12675672.10 | 3802701.63 | 6.85 | 01-MAR-06:01 | 2.06 | 2.06 | 56.39 | 0.05 |
April | 11960507.72 | 3588152.32 | 6.85 | 01-APR-05:05 | 2.06 | 2.06 | 55.57 | 0.05 |
May | 12527707.06 | 3758312.12 | 6.85 | 01-MAY-05:05 | 2.06 | 2.06 | 55.85 | 0.05 |
June | 12231776.97 | 3669533.09 | 6.85 | 01-JUN-05:03 | 2.06 | 2.06 | 55.75 | 0.05 |
July | 12256437.81 | 3676931.34 | 6.85 | 01-JUL-05:05 | 2.06 | 2.06 | 55.67 | 0.05 |
August | 12675672.10 | 3802701.63 | 6.85 | 01-AUG-05:05 | 2.06 | 2.06 | 56.52 | 0.05 |
September | 11960507.72 | 3588152.32 | 6.85 | 01-SEP-05:03 | 2.06 | 2.06 | 56.27 | 0.05 |
October | 12379742.02 | 3713922.60 | 6.85 | 01-OCT-05:10 | 2.06 | 2.06 | 57.08 | 0.05 |
November | 12059151.09 | 3617745.33 | 6.85 | 01-NOV-05:01 | 2.06 | 2.06 | 56.60 | 0.05 |
December | 12256437.81 | 3676931.34 | 6.85 | 01-DEC-06:05 | 2.06 | 2.06 | 55.90 | 0.05 |
Annual Sum or Average | 0.146559E+09 | 43967812.83 | ||||||
Minimum of Months | 11196021.66 | 3358806.50 | 6.85 | 2.06 | 2.06 | 55.57 | 0.05 | |
Maximum of Months | 12675672.10 | 3802701.63 | 6.85 | 2.06 | 2.06 | 57.08 | 0.05 |
Report: CondLoopDemandReportMonthly
For: SWHSYS1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportPLANT SUPPLY SIDE COOLING DEMAND RATE [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} | PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] | PLANT SUPPLY SIDE HEATING DEMAND RATE [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] | PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP} | |
January | 0.00 | 0.00 | 01-JAN-00:10 | 57.64 | 57.64 | 1932.36 | 6772.53 | 31-JAN-12:06 |
February | 0.00 | 0.00 | 01-FEB-00:10 | 57.07 | 57.07 | 1966.00 | 6808.02 | 14-FEB-12:10 |
March | 0.00 | 0.00 | 01-MAR-00:10 | 57.04 | 57.04 | 2065.94 | 6782.91 | 01-MAR-12:09 |
April | 0.00 | 0.00 | 01-APR-00:10 | 57.14 | 57.14 | 1858.71 | 6566.17 | 03-APR-11:13 |
May | 0.00 | 0.00 | 01-MAY-00:10 | 56.63 | 56.63 | 1828.15 | 6253.44 | 01-MAY-11:07 |
June | 0.00 | 0.00 | 01-JUN-00:10 | 56.20 | 56.20 | 1772.44 | 5876.40 | 01-JUN-11:40 |
July | 0.00 | 0.00 | 01-JUL-00:10 | 56.11 | 56.11 | 1557.74 | 5559.65 | 03-JUL-12:00 |
August | 0.00 | 0.00 | 01-AUG-00:10 | 56.95 | 56.95 | 1687.05 | 5420.64 | 31-AUG-11:10 |
September | 0.00 | 0.00 | 01-SEP-00:10 | 56.65 | 56.65 | 1604.13 | 5581.19 | 29-SEP-11:40 |
October | 0.00 | 0.00 | 01-OCT-00:10 | 55.67 | 55.67 | 1675.14 | 5949.81 | 31-OCT-11:06 |
November | 0.00 | 0.00 | 01-NOV-00:10 | 56.97 | 56.97 | 1796.76 | 6298.73 | 30-NOV-12:10 |
December | 0.00 | 0.00 | 01-DEC-00:10 | 56.60 | 56.60 | 1815.35 | 6574.19 | 29-DEC-12:06 |
Annual Sum or Average | 0.00 | 1795.68 | ||||||
Minimum of Months | 0.00 | 0.00 | 55.67 | 55.67 | 1557.74 | 5420.64 | ||
Maximum of Months | 0.00 | 0.00 | 57.64 | 57.64 | 2065.94 | 6808.02 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: TOPFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: MIDFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: FIRSTFLOOR_PLENUM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: ZoneTemperatureOscillationReportMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] | ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} [] | |
January | 0.00 | 0.00 |
February | 0.00 | 0.00 |
March | 0.00 | 0.00 |
April | 0.00 | 0.00 |
May | 0.00 | 0.00 |
June | 0.00 | 0.00 |
July | 0.00 | 0.00 |
August | 0.00 | 0.00 |
September | 0.00 | 0.00 |
October | 0.00 | 0.00 |
November | 0.00 | 0.00 |
December | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | |
Minimum of Months | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.807218E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.869398E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.770599E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.566954E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.757553E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.210077E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.206595E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.207713E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.149578E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.812200E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.618899E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.977138E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.139196E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.566954E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.210077E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.531861E+10 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.641960E+10 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.506639E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.361070E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.616022E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.192633E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.189359E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.183275E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.122295E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.569063E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.452192E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.903388E+10 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.114578E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.361070E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.192633E+11 | 0.00 | 0.00 |
Report: AirLoopSystemEnergyAndWaterUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM HOT WATER ENERGY [J] | AIR SYSTEM STEAM ENERGY [J] | AIR SYSTEM CHILLED WATER ENERGY [J] | AIR SYSTEM ELECTRICITY ENERGY [J] | AIR SYSTEM NATURAL GAS ENERGY [] | AIR SYSTEM WATER VOLUME [m3] | |
January | 0.00 | 0.00 | 0.00 | 0.113255E+11 | 0.00 | 0.00 |
February | 0.00 | 0.00 | 0.00 | 0.132679E+11 | 0.00 | 0.00 |
March | 0.00 | 0.00 | 0.00 | 0.962341E+10 | 0.00 | 0.00 |
April | 0.00 | 0.00 | 0.00 | 0.667970E+10 | 0.00 | 0.00 |
May | 0.00 | 0.00 | 0.00 | 0.649305E+10 | 0.00 | 0.00 |
June | 0.00 | 0.00 | 0.00 | 0.203964E+11 | 0.00 | 0.00 |
July | 0.00 | 0.00 | 0.00 | 0.198349E+11 | 0.00 | 0.00 |
August | 0.00 | 0.00 | 0.00 | 0.191942E+11 | 0.00 | 0.00 |
September | 0.00 | 0.00 | 0.00 | 0.122187E+11 | 0.00 | 0.00 |
October | 0.00 | 0.00 | 0.00 | 0.858636E+10 | 0.00 | 0.00 |
November | 0.00 | 0.00 | 0.00 | 0.919689E+10 | 0.00 | 0.00 |
December | 0.00 | 0.00 | 0.00 | 0.193120E+11 | 0.00 | 0.00 |
Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.156129E+12 | 0.00 | 0.00 |
Minimum of Months | 0.00 | 0.00 | 0.00 | 0.649305E+10 | 0.00 | 0.00 |
Maximum of Months | 0.00 | 0.00 | 0.00 | 0.203964E+11 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.170505E+10 | 0.319051E+10 | 0.131479E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155918E+10 | 0.147274E+10 | 0.141906E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.222426E+10 | 0.375964E+10 | 0.923961E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.182898E+10 | 0.388969E+10 | 0.553941E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.313123E+10 | 0.151114E+11 | 0.829315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.674719E+10 | 0.538033E+11 | 11417023.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.640487E+10 | 0.546444E+11 | 3281793.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.671137E+10 | 0.541523E+11 | 1228554.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.534023E+10 | 0.378275E+11 | 0.230754E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.289365E+10 | 0.110476E+11 | 0.538259E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.202226E+10 | 0.409568E+10 | 0.860666E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.162765E+10 | 0.188006E+10 | 0.176376E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.421959E+11 | 0.244875E+12 | 0.748204E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.155918E+10 | 0.147274E+10 | 1228554.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.674719E+10 | 0.546444E+11 | 0.176376E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.143213E+10 | 0.177146E+10 | 0.114644E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136837E+10 | 0.118277E+10 | 0.126551E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.191795E+10 | 0.334064E+10 | 0.770091E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.158527E+10 | 0.261166E+10 | 0.472004E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.282416E+10 | 0.131475E+11 | 0.397504E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.620758E+10 | 0.492687E+11 | 50863.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.587751E+10 | 0.499775E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.593010E+10 | 0.475703E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.428434E+10 | 0.314155E+11 | 0.244416E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.210180E+10 | 0.726465E+10 | 0.557361E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.153643E+10 | 0.245749E+10 | 0.871618E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.142230E+10 | 0.113793E+10 | 0.180826E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.364879E+11 | 0.211146E+12 | 0.695548E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.136837E+10 | 0.113793E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.620758E+10 | 0.499775E+11 | 0.180826E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentLoadsMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM FAN AIR HEATING ENERGY [J] | AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] | AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] | AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] | AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] | AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J] | |
January | 0.165777E+10 | 0.964104E+09 | 0.181776E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161357E+10 | 0.152123E+10 | 0.198855E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.206979E+10 | 0.350335E+10 | 0.125601E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.172822E+10 | 0.263576E+10 | 0.793163E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.266503E+10 | 0.140827E+11 | 0.729333E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.596598E+10 | 0.540045E+11 | 1163005.08 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.555428E+10 | 0.541330E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.559873E+10 | 0.516628E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.382854E+10 | 0.325314E+11 | 0.378391E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.203629E+10 | 0.621158E+10 | 0.946100E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.160826E+10 | 0.238830E+10 | 0.139545E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.178929E+10 | 0.100450E+10 | 0.291211E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.361158E+11 | 0.224643E+12 | 0.112200E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.160826E+10 | 0.964104E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.596598E+10 | 0.541330E+11 | 0.291211E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_BOT
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.170505E+10 | 0.00 | 0.00 | 0.00 | 0.817539E+09 | 0.554960E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.155918E+10 | 0.00 | 0.00 | 0.00 | 0.407289E+09 | 0.672751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.222426E+10 | 0.00 | 0.00 | 0.00 | 0.956791E+09 | 0.452495E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.182898E+10 | 0.00 | 0.00 | 0.00 | 0.103693E+10 | 0.280363E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.313123E+10 | 0.00 | 0.00 | 0.00 | 0.380641E+10 | 0.637889E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.674719E+10 | 0.00 | 0.00 | 0.00 | 0.142491E+11 | 11417023.65 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.640487E+10 | 0.00 | 0.00 | 0.00 | 0.142514E+11 | 3281793.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.671137E+10 | 0.00 | 0.00 | 0.00 | 0.140587E+11 | 1228554.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.534023E+10 | 0.00 | 0.00 | 0.00 | 0.951133E+10 | 0.106243E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.289365E+10 | 0.00 | 0.00 | 0.00 | 0.275565E+10 | 0.247270E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.202226E+10 | 0.00 | 0.00 | 0.00 | 0.105657E+10 | 0.311015E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.162765E+10 | 0.00 | 0.00 | 0.00 | 0.500614E+09 | 0.764312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.421959E+11 | 0.00 | 0.00 | 0.00 | 0.634083E+11 | 0.335917E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.155918E+10 | 0.00 | 0.00 | 0.00 | 0.407289E+09 | 1228554.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.674719E+10 | 0.00 | 0.00 | 0.00 | 0.142514E+11 | 0.764312E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.143213E+10 | 0.00 | 0.00 | 0.00 | 0.464031E+09 | 0.342245E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.136837E+10 | 0.00 | 0.00 | 0.00 | 0.321720E+09 | 0.472951E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.191795E+10 | 0.00 | 0.00 | 0.00 | 0.838334E+09 | 0.231010E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.158527E+10 | 0.00 | 0.00 | 0.00 | 0.690023E+09 | 0.133540E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.282416E+10 | 0.00 | 0.00 | 0.00 | 0.329177E+10 | 44285480.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.620758E+10 | 0.00 | 0.00 | 0.00 | 0.130557E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.587751E+10 | 0.00 | 0.00 | 0.00 | 0.130583E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.593010E+10 | 0.00 | 0.00 | 0.00 | 0.123974E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.428434E+10 | 0.00 | 0.00 | 0.00 | 0.794071E+10 | 4434791.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.210180E+10 | 0.00 | 0.00 | 0.00 | 0.181463E+10 | 0.177420E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.153643E+10 | 0.00 | 0.00 | 0.00 | 0.634999E+09 | 0.235049E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.142230E+10 | 0.00 | 0.00 | 0.00 | 0.307816E+09 | 0.730375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.364879E+11 | 0.00 | 0.00 | 0.00 | 0.548156E+11 | 0.232746E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.136837E+10 | 0.00 | 0.00 | 0.00 | 0.307816E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.620758E+10 | 0.00 | 0.00 | 0.00 | 0.130583E+11 | 0.730375E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: AirLoopSystemComponentEnergyUseMonthly
For: PACU_VAV_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportAIR SYSTEM FAN ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] | AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] | AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] | AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] | AIR SYSTEM HEATING COIL STEAM ENERGY [J] | AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] | AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] | AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] | AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J] | |
January | 0.165777E+10 | 0.00 | 0.00 | 0.00 | 0.261384E+09 | 0.940630E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
February | 0.161357E+10 | 0.00 | 0.00 | 0.00 | 0.416048E+09 | 0.112383E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
March | 0.206979E+10 | 0.00 | 0.00 | 0.00 | 0.892295E+09 | 0.666132E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
April | 0.172822E+10 | 0.00 | 0.00 | 0.00 | 0.700256E+09 | 0.425122E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
May | 0.266503E+10 | 0.00 | 0.00 | 0.00 | 0.355585E+10 | 0.272166E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
June | 0.596598E+10 | 0.00 | 0.00 | 0.00 | 0.144304E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
July | 0.555428E+10 | 0.00 | 0.00 | 0.00 | 0.142806E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
August | 0.559873E+10 | 0.00 | 0.00 | 0.00 | 0.135955E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
September | 0.382854E+10 | 0.00 | 0.00 | 0.00 | 0.831427E+10 | 75918675.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
October | 0.203629E+10 | 0.00 | 0.00 | 0.00 | 0.157975E+10 | 0.497032E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
November | 0.160826E+10 | 0.00 | 0.00 | 0.00 | 0.631121E+09 | 0.695751E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
December | 0.178929E+10 | 0.00 | 0.00 | 0.00 | 0.276178E+09 | 0.172465E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Annual Sum or Average | 0.361158E+11 | 0.00 | 0.00 | 0.00 | 0.589336E+11 | 0.610796E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Minimum of Months | 0.160826E+10 | 0.00 | 0.00 | 0.00 | 0.261384E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Maximum of Months | 0.596598E+10 | 0.00 | 0.00 | 0.00 | 0.144304E+11 | 0.172465E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_BOTTOM
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.360496E+10 | 0.00 | 0.00 | 26040072.77 | 0.00 | 0.00 | 0.127153E+11 | 0.00 | 0.39 |
February | 0.425805E+10 | 0.00 | 0.00 | 22425531.57 | 0.00 | 0.00 | 0.112474E+11 | 0.00 | 0.40 |
March | 0.234114E+10 | 0.00 | 0.00 | 31968797.93 | 0.00 | 0.00 | 0.166325E+11 | 0.00 | 0.65 |
April | 0.148713E+10 | 0.00 | 0.00 | 27870561.84 | 0.00 | 0.00 | 0.138783E+11 | 0.00 | 0.60 |
May | 0.446386E+09 | 2783097.02 | 0.00 | 42067659.04 | 2020121.83 | 0.00 | 0.162827E+11 | 0.00 | 0.96 |
June | 0.321653E+09 | 0.489339E+09 | 0.00 | 31605379.68 | 69083877.00 | 0.00 | 0.552668E+10 | 0.00 | 0.83 |
July | 0.284803E+09 | 0.638605E+09 | 0.00 | 27434246.25 | 0.120536E+09 | 0.00 | 0.396618E+10 | 0.00 | 0.77 |
August | 0.406582E+09 | 0.459410E+09 | 0.00 | 40317907.22 | 41229129.89 | 0.00 | 0.742159E+10 | 0.00 | 0.88 |
September | 0.506331E+09 | 64508544.51 | 0.00 | 44090482.63 | 20902673.91 | 0.00 | 0.107900E+11 | 0.00 | 0.97 |
October | 0.149181E+10 | 0.00 | 0.00 | 40562773.28 | 0.00 | 0.00 | 0.169614E+11 | 0.00 | 0.67 |
November | 0.213633E+10 | 0.00 | 0.00 | 32623728.36 | 0.00 | 0.00 | 0.159678E+11 | 0.00 | 0.53 |
December | 0.447159E+10 | 0.00 | 0.00 | 22268359.90 | 0.00 | 502178.89 | 0.125037E+11 | 0.00 | 0.38 |
Annual Sum or Average | 0.217568E+11 | 0.165464E+10 | 0.00 | 0.389276E+09 | 0.253772E+09 | 502178.89 | 0.143894E+12 | 0.00 | 0.67 |
Minimum of Months | 0.284803E+09 | 0.00 | 0.00 | 22268359.90 | 0.00 | 0.00 | 0.396618E+10 | 0.00 | 0.38 |
Maximum of Months | 0.447159E+10 | 0.638605E+09 | 0.00 | 44090482.63 | 0.120536E+09 | 502178.89 | 0.169614E+11 | 0.00 | 0.97 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_MID
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.100894E+11 | 0.00 | 0.00 | 3611542.97 | 0.00 | 0.129125E+09 | 0.199917E+10 | 0.00 | 0.29 |
February | 0.897106E+10 | 0.00 | 0.00 | 2901702.86 | 0.00 | 0.493274E+09 | 0.182093E+10 | 0.00 | 0.29 |
March | 0.739659E+10 | 0.00 | 0.00 | 9444025.49 | 0.00 | 67154992.53 | 0.549604E+10 | 0.00 | 0.43 |
April | 0.587983E+10 | 0.00 | 0.00 | 8222950.70 | 0.00 | 82737110.74 | 0.485031E+10 | 0.00 | 0.41 |
May | 0.162002E+10 | 1429483.92 | 0.00 | 22373764.31 | 1707853.17 | 0.00 | 0.952390E+10 | 0.00 | 0.63 |
June | 0.524340E+09 | 0.336255E+09 | 0.00 | 22056477.04 | 54493250.61 | 0.00 | 0.366069E+10 | 0.00 | 0.60 |
July | 0.394764E+09 | 0.432811E+09 | 0.00 | 19445866.11 | 0.116058E+09 | 0.00 | 0.273509E+10 | 0.00 | 0.56 |
August | 0.611339E+09 | 0.325527E+09 | 0.00 | 27522528.44 | 31208412.83 | 0.00 | 0.486683E+10 | 0.00 | 0.62 |
September | 0.824376E+09 | 49254934.18 | 0.00 | 26617539.42 | 18484494.79 | 0.00 | 0.665744E+10 | 0.00 | 0.65 |
October | 0.493982E+10 | 0.00 | 0.00 | 14449845.91 | 0.00 | 60545436.04 | 0.726998E+10 | 0.00 | 0.44 |
November | 0.816580E+10 | 0.00 | 0.00 | 6198833.44 | 0.00 | 34594343.54 | 0.387433E+10 | 0.00 | 0.35 |
December | 0.109909E+11 | 0.00 | 0.00 | 1594987.39 | 0.00 | 0.540426E+09 | 0.147497E+10 | 0.00 | 0.30 |
Annual Sum or Average | 0.604083E+11 | 0.114528E+10 | 0.00 | 0.164440E+09 | 0.221952E+09 | 0.140786E+10 | 0.542297E+11 | 0.00 | 0.47 |
Minimum of Months | 0.394764E+09 | 0.00 | 0.00 | 1594987.39 | 0.00 | 0.00 | 0.147497E+10 | 0.00 | 0.29 |
Maximum of Months | 0.109909E+11 | 0.432811E+09 | 0.00 | 27522528.44 | 0.116058E+09 | 0.540426E+09 | 0.952390E+10 | 0.00 | 0.65 |
Report: MechanicalVentilationLoadsMonthly
For: CORE_TOP
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.885190E+10 | 0.00 | 0.00 | 1389364.13 | 0.00 | 0.141250E+10 | 0.117103E+10 | 0.00 | 0.29 |
February | 0.766996E+10 | 0.00 | 0.00 | 1246173.27 | 0.00 | 0.175747E+10 | 0.936617E+09 | 0.00 | 0.27 |
March | 0.735502E+10 | 0.00 | 0.00 | 6570020.71 | 0.00 | 0.643806E+09 | 0.415033E+10 | 0.00 | 0.41 |
April | 0.570481E+10 | 0.00 | 0.00 | 6551437.62 | 0.00 | 0.545420E+09 | 0.421252E+10 | 0.00 | 0.40 |
May | 0.229989E+10 | 231493.87 | 0.00 | 19434425.36 | 664147.80 | 24452759.18 | 0.841566E+10 | 0.00 | 0.62 |
June | 0.625181E+09 | 0.265165E+09 | 0.00 | 23384000.60 | 47749218.38 | 0.00 | 0.336374E+10 | 0.00 | 0.63 |
July | 0.464511E+09 | 0.347290E+09 | 0.00 | 20389162.30 | 0.108123E+09 | 0.00 | 0.237385E+10 | 0.00 | 0.58 |
August | 0.655436E+09 | 0.267245E+09 | 0.00 | 26789646.53 | 24438498.01 | 0.00 | 0.424415E+10 | 0.00 | 0.61 |
September | 0.127646E+10 | 35221897.62 | 0.00 | 22761831.96 | 13814422.32 | 0.00 | 0.521533E+10 | 0.00 | 0.61 |
October | 0.549610E+10 | 0.00 | 0.00 | 8255791.99 | 0.00 | 0.782335E+09 | 0.465870E+10 | 0.00 | 0.42 |
November | 0.805816E+10 | 0.00 | 0.00 | 3071012.10 | 0.00 | 0.780900E+09 | 0.201888E+10 | 0.00 | 0.32 |
December | 0.843391E+10 | 0.00 | 0.00 | 418539.45 | 0.00 | 0.281172E+10 | 0.517326E+09 | 0.00 | 0.28 |
Annual Sum or Average | 0.568913E+11 | 0.915153E+09 | 0.00 | 0.140261E+09 | 0.194790E+09 | 0.875861E+10 | 0.412781E+11 | 0.00 | 0.46 |
Minimum of Months | 0.464511E+09 | 0.00 | 0.00 | 418539.45 | 0.00 | 0.00 | 0.517326E+09 | 0.00 | 0.27 |
Maximum of Months | 0.885190E+10 | 0.347290E+09 | 0.00 | 26789646.53 | 0.108123E+09 | 0.281172E+10 | 0.841566E+10 | 0.00 | 0.63 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.931098E+09 | 0.00 | 0.00 | 12513.94 | 0.00 | 0.179327E+10 | 10461743.60 | 0.00 | 0.32 |
February | 0.813015E+09 | 0.00 | 0.00 | 4487.10 | 0.00 | 0.167401E+10 | 7004827.93 | 0.00 | 0.30 |
March | 0.115507E+10 | 0.00 | 0.00 | 733222.12 | 0.00 | 0.101878E+10 | 0.381333E+09 | 0.00 | 0.40 |
April | 0.105333E+10 | 0.00 | 0.00 | 1052732.54 | 0.00 | 0.615824E+09 | 0.590347E+09 | 0.00 | 0.41 |
May | 0.662854E+09 | 80389.26 | 0.00 | 4646234.19 | 140257.30 | 34326809.94 | 0.171624E+10 | 0.00 | 0.73 |
June | 0.135529E+09 | 0.102399E+09 | 0.00 | 7275403.78 | 7794854.10 | 0.00 | 0.891253E+09 | 0.00 | 0.87 |
July | 0.109428E+09 | 0.131925E+09 | 0.00 | 6054136.04 | 18494027.82 | 0.00 | 0.592521E+09 | 0.00 | 0.77 |
August | 0.191846E+09 | 91968900.77 | 0.00 | 7007681.07 | 4606903.43 | 0.00 | 0.926356E+09 | 0.00 | 0.73 |
September | 0.398202E+09 | 13679716.04 | 0.00 | 5182601.54 | 2816648.37 | 16503206.92 | 0.935432E+09 | 0.00 | 0.65 |
October | 0.112894E+10 | 0.00 | 0.00 | 902849.16 | 0.00 | 0.793756E+09 | 0.406003E+09 | 0.00 | 0.41 |
November | 0.919922E+09 | 0.00 | 0.00 | 225192.89 | 0.00 | 0.140981E+10 | 0.121918E+09 | 0.00 | 0.33 |
December | 0.648408E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.277498E+10 | 0.00 | 0.00 | 0.35 |
Annual Sum or Average | 0.814764E+10 | 0.340053E+09 | 0.00 | 33097054.38 | 33852691.01 | 0.101313E+11 | 0.657887E+10 | 0.00 | 0.52 |
Minimum of Months | 0.109428E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.30 |
Maximum of Months | 0.115507E+10 | 0.131925E+09 | 0.00 | 7275403.78 | 18494027.82 | 0.277498E+10 | 0.171624E+10 | 0.00 | 0.87 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.689692E+09 | 0.00 | 0.00 | 440465.08 | 0.00 | 0.822274E+09 | 0.239852E+09 | 0.00 | 0.33 |
February | 0.636668E+09 | 0.00 | 0.00 | 778110.41 | 0.00 | 0.710864E+09 | 0.388513E+09 | 0.00 | 0.35 |
March | 0.582919E+09 | 0.00 | 0.00 | 2874199.80 | 0.00 | 0.460828E+09 | 0.147260E+10 | 0.00 | 0.69 |
April | 0.482780E+09 | 0.00 | 0.00 | 3032887.03 | 0.00 | 0.300542E+09 | 0.163784E+10 | 0.00 | 0.75 |
May | 0.274138E+09 | 71255.34 | 0.00 | 6391993.39 | 88912.44 | 8999724.07 | 0.247211E+10 | 0.00 | 1.29 |
June | 40323541.63 | 84928302.91 | 0.00 | 9480283.89 | 3423308.71 | 0.00 | 0.145007E+10 | 0.00 | 1.66 |
July | 39847383.52 | 0.126225E+09 | 0.00 | 8077640.80 | 5231579.58 | 0.00 | 0.776569E+09 | 0.00 | 1.31 |
August | 69048976.42 | 79123608.17 | 0.00 | 10210203.09 | 2716859.00 | 0.00 | 0.171230E+10 | 0.00 | 1.54 |
September | 0.154782E+09 | 12600949.50 | 0.00 | 7823628.43 | 1788103.79 | 6529436.33 | 0.155965E+10 | 0.00 | 1.31 |
October | 0.501661E+09 | 0.00 | 0.00 | 2705448.64 | 0.00 | 0.479542E+09 | 0.120884E+10 | 0.00 | 0.67 |
November | 0.650973E+09 | 0.00 | 0.00 | 890188.39 | 0.00 | 0.657096E+09 | 0.422145E+09 | 0.00 | 0.40 |
December | 0.587798E+09 | 0.00 | 0.00 | 63931.33 | 0.00 | 0.140259E+10 | 54205011.58 | 0.00 | 0.34 |
Annual Sum or Average | 0.471063E+10 | 0.302949E+09 | 0.00 | 52768980.28 | 13248763.52 | 0.484926E+10 | 0.133947E+11 | 0.00 | 0.89 |
Minimum of Months | 39847383.52 | 0.00 | 0.00 | 63931.33 | 0.00 | 0.00 | 54205011.58 | 0.00 | 0.33 |
Maximum of Months | 0.689692E+09 | 0.126225E+09 | 0.00 | 10210203.09 | 5231579.58 | 0.140259E+10 | 0.247211E+10 | 0.00 | 1.66 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.792873E+09 | 0.00 | 0.00 | 8188659.74 | 0.00 | 0.860722E+09 | 0.417429E+10 | 0.00 | 0.84 |
February | 0.723431E+09 | 0.00 | 0.00 | 8180468.11 | 0.00 | 0.827500E+09 | 0.370069E+10 | 0.00 | 0.71 |
March | 0.769476E+09 | 0.00 | 0.00 | 8392221.31 | 0.00 | 0.701415E+09 | 0.415299E+10 | 0.00 | 1.04 |
April | 0.858092E+09 | 0.00 | 0.00 | 4680959.06 | 0.00 | 0.448450E+09 | 0.256747E+10 | 0.00 | 0.79 |
May | 0.560724E+09 | 95604.76 | 0.00 | 7219968.18 | 140014.33 | 31675516.01 | 0.273362E+10 | 0.00 | 1.00 |
June | 0.168109E+09 | 0.117008E+09 | 0.00 | 8375558.99 | 7091322.25 | 0.00 | 0.955369E+09 | 0.00 | 0.96 |
July | 0.118287E+09 | 0.187715E+09 | 0.00 | 7237507.69 | 10267767.37 | 0.00 | 0.656502E+09 | 0.00 | 0.89 |
August | 0.171933E+09 | 0.134642E+09 | 0.00 | 11814904.57 | 4222731.47 | 0.00 | 0.145927E+10 | 0.00 | 1.05 |
September | 0.274861E+09 | 26910662.63 | 0.00 | 13694098.63 | 2543964.76 | 14157178.56 | 0.232820E+10 | 0.00 | 1.32 |
October | 0.611469E+09 | 0.00 | 0.00 | 12932818.07 | 0.00 | 0.683409E+09 | 0.471869E+10 | 0.00 | 1.29 |
November | 0.723505E+09 | 0.00 | 0.00 | 9389161.60 | 0.00 | 0.737539E+09 | 0.405487E+10 | 0.00 | 0.92 |
December | 0.829712E+09 | 0.00 | 0.00 | 6147615.97 | 0.00 | 0.141217E+10 | 0.277460E+10 | 0.00 | 0.71 |
Annual Sum or Average | 0.660247E+10 | 0.466371E+09 | 0.00 | 0.106254E+09 | 24265800.18 | 0.571704E+10 | 0.342766E+11 | 0.00 | 0.96 |
Minimum of Months | 0.118287E+09 | 0.00 | 0.00 | 4680959.06 | 0.00 | 0.00 | 0.656502E+09 | 0.00 | 0.71 |
Maximum of Months | 0.858092E+09 | 0.187715E+09 | 0.00 | 13694098.63 | 10267767.37 | 0.141217E+10 | 0.471869E+10 | 0.00 | 1.32 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_TOP_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.554133E+09 | 0.00 | 0.00 | 818202.66 | 0.00 | 0.942825E+09 | 0.536127E+09 | 0.00 | 0.41 |
February | 0.523188E+09 | 0.00 | 0.00 | 1109094.02 | 0.00 | 0.847256E+09 | 0.594951E+09 | 0.00 | 0.39 |
March | 0.621048E+09 | 0.00 | 0.00 | 2884445.95 | 0.00 | 0.548654E+09 | 0.139337E+10 | 0.00 | 0.76 |
April | 0.577110E+09 | 0.00 | 0.00 | 2661994.71 | 0.00 | 0.321620E+09 | 0.140146E+10 | 0.00 | 0.74 |
May | 0.320236E+09 | 100717.49 | 0.00 | 5632859.92 | 88385.07 | 21362319.36 | 0.202986E+10 | 0.00 | 1.18 |
June | 94047406.99 | 0.120643E+09 | 0.00 | 7223065.81 | 2356516.18 | 0.00 | 0.696435E+09 | 0.00 | 1.18 |
July | 70813762.67 | 0.134123E+09 | 0.00 | 5249514.85 | 7492877.40 | 0.00 | 0.481011E+09 | 0.00 | 1.03 |
August | 0.105144E+09 | 0.102259E+09 | 0.00 | 7665506.08 | 1649899.31 | 0.00 | 0.797522E+09 | 0.00 | 1.03 |
September | 0.201379E+09 | 16785050.67 | 0.00 | 6537955.35 | 924504.01 | 11097796.46 | 0.109334E+10 | 0.00 | 1.06 |
October | 0.560021E+09 | 0.00 | 0.00 | 3515210.82 | 0.00 | 0.486658E+09 | 0.134626E+10 | 0.00 | 0.79 |
November | 0.560164E+09 | 0.00 | 0.00 | 1209027.70 | 0.00 | 0.736863E+09 | 0.619527E+09 | 0.00 | 0.46 |
December | 0.459528E+09 | 0.00 | 0.00 | 401280.85 | 0.00 | 0.151183E+10 | 0.244172E+09 | 0.00 | 0.39 |
Annual Sum or Average | 0.464681E+10 | 0.373910E+09 | 0.00 | 44908158.72 | 12512181.97 | 0.542817E+10 | 0.112340E+11 | 0.00 | 0.79 |
Minimum of Months | 70813762.67 | 0.00 | 0.00 | 401280.85 | 0.00 | 0.00 | 0.244172E+09 | 0.00 | 0.39 |
Maximum of Months | 0.621048E+09 | 0.134123E+09 | 0.00 | 7665506.08 | 7492877.40 | 0.151183E+10 | 0.202986E+10 | 0.00 | 1.18 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.918624E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.160635E+10 | 0.00 | 0.00 | 0.27 |
February | 0.742392E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.169728E+10 | 0.00 | 0.00 | 0.28 |
March | 0.121536E+10 | 0.00 | 0.00 | 152353.57 | 0.00 | 0.101908E+10 | 84875305.35 | 0.00 | 0.34 |
April | 0.134780E+10 | 0.00 | 0.00 | 171798.54 | 0.00 | 0.402033E+09 | 0.119259E+09 | 0.00 | 0.31 |
May | 0.766599E+09 | 420318.14 | 0.00 | 2600197.69 | 441627.04 | 15566914.40 | 0.887058E+09 | 0.00 | 0.48 |
June | 0.138793E+09 | 0.107739E+09 | 0.00 | 4478852.42 | 14567362.59 | 0.00 | 0.650416E+09 | 0.00 | 0.62 |
July | 0.115107E+09 | 0.137323E+09 | 0.00 | 3882530.12 | 25416806.98 | 0.00 | 0.465605E+09 | 0.00 | 0.58 |
August | 0.166771E+09 | 97669308.82 | 0.00 | 5444930.19 | 8693775.02 | 0.00 | 0.829612E+09 | 0.00 | 0.61 |
September | 0.363895E+09 | 15547189.95 | 0.00 | 5044999.85 | 4411536.98 | 0.00 | 0.988779E+09 | 0.00 | 0.63 |
October | 0.118785E+10 | 0.00 | 0.00 | 976972.72 | 0.00 | 0.389443E+09 | 0.378382E+09 | 0.00 | 0.33 |
November | 0.132409E+10 | 0.00 | 0.00 | 167162.90 | 0.00 | 0.765957E+09 | 93240219.95 | 0.00 | 0.28 |
December | 0.869315E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.203047E+10 | 0.00 | 0.00 | 0.29 |
Annual Sum or Average | 0.915660E+10 | 0.358699E+09 | 0.00 | 22919797.99 | 53531108.61 | 0.792618E+10 | 0.449723E+10 | 0.00 | 0.42 |
Minimum of Months | 0.115107E+09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.27 |
Maximum of Months | 0.134780E+10 | 0.137323E+09 | 0.00 | 5444930.19 | 25416806.98 | 0.203047E+10 | 0.988779E+09 | 0.00 | 0.63 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.830460E+09 | 0.00 | 0.00 | 345832.82 | 0.00 | 0.654741E+09 | 0.112260E+09 | 0.00 | 0.27 |
February | 0.678046E+09 | 0.00 | 0.00 | 658344.68 | 0.00 | 0.674072E+09 | 0.320176E+09 | 0.00 | 0.32 |
March | 0.672822E+09 | 0.00 | 0.00 | 2167553.19 | 0.00 | 0.376698E+09 | 0.104199E+10 | 0.00 | 0.56 |
April | 0.641053E+09 | 0.00 | 0.00 | 2242404.35 | 0.00 | 0.153566E+09 | 0.102410E+10 | 0.00 | 0.55 |
May | 0.268649E+09 | 477696.95 | 0.00 | 4923926.39 | 269653.91 | 728169.07 | 0.174182E+10 | 0.00 | 0.95 |
June | 33297032.15 | 0.101423E+09 | 0.00 | 6883770.39 | 7315323.51 | 0.00 | 0.118812E+10 | 0.00 | 1.31 |
July | 29475677.25 | 0.138784E+09 | 0.00 | 5819988.32 | 10827420.96 | 0.00 | 0.707058E+09 | 0.00 | 1.08 |
August | 64961601.34 | 0.103109E+09 | 0.00 | 8633025.22 | 4636096.69 | 0.00 | 0.154252E+10 | 0.00 | 1.37 |
September | 0.134573E+09 | 16140751.40 | 0.00 | 7861992.99 | 2666147.24 | 0.00 | 0.170383E+10 | 0.00 | 1.31 |
October | 0.506779E+09 | 0.00 | 0.00 | 3438563.05 | 0.00 | 0.222729E+09 | 0.123650E+10 | 0.00 | 0.60 |
November | 0.831762E+09 | 0.00 | 0.00 | 1220034.50 | 0.00 | 0.311496E+09 | 0.484079E+09 | 0.00 | 0.37 |
December | 0.731958E+09 | 0.00 | 0.00 | 116824.76 | 0.00 | 0.978911E+09 | 71084301.50 | 0.00 | 0.28 |
Annual Sum or Average | 0.542384E+10 | 0.359935E+09 | 0.00 | 44312260.66 | 25714642.30 | 0.337294E+10 | 0.111735E+11 | 0.00 | 0.75 |
Minimum of Months | 29475677.25 | 0.00 | 0.00 | 116824.76 | 0.00 | 0.00 | 71084301.50 | 0.00 | 0.27 |
Maximum of Months | 0.831762E+09 | 0.138784E+09 | 0.00 | 8633025.22 | 10827420.96 | 0.978911E+09 | 0.174182E+10 | 0.00 | 1.37 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.994571E+09 | 0.00 | 0.00 | 4201123.49 | 0.00 | 0.158539E+10 | 0.175004E+10 | 0.00 | 0.52 |
February | 0.896185E+09 | 0.00 | 0.00 | 3505794.75 | 0.00 | 0.174666E+10 | 0.160726E+10 | 0.00 | 0.57 |
March | 0.893058E+09 | 0.00 | 0.00 | 3914157.40 | 0.00 | 0.142034E+10 | 0.175902E+10 | 0.00 | 0.75 |
April | 0.104774E+10 | 0.00 | 0.00 | 1455853.38 | 0.00 | 0.954693E+09 | 0.657101E+09 | 0.00 | 0.49 |
May | 0.798308E+09 | 698662.88 | 0.00 | 3064656.51 | 426357.74 | 0.246697E+09 | 0.845129E+09 | 0.00 | 0.57 |
June | 0.225058E+09 | 0.147253E+09 | 0.00 | 4828035.08 | 14179630.37 | 7540273.12 | 0.509924E+09 | 0.00 | 0.67 |
July | 0.170907E+09 | 0.197211E+09 | 0.00 | 4204870.31 | 21666404.03 | 2885209.72 | 0.388070E+09 | 0.00 | 0.65 |
August | 0.244548E+09 | 0.176971E+09 | 0.00 | 9116710.05 | 6088275.34 | 715808.07 | 0.103180E+10 | 0.00 | 0.88 |
September | 0.327389E+09 | 34573098.95 | 0.00 | 11772220.05 | 3450961.84 | 51056216.27 | 0.195108E+10 | 0.00 | 1.22 |
October | 0.516729E+09 | 0.00 | 0.00 | 11483179.61 | 0.00 | 0.102918E+10 | 0.322446E+10 | 0.00 | 0.99 |
November | 0.867743E+09 | 0.00 | 0.00 | 6800750.60 | 0.00 | 0.118490E+10 | 0.258725E+10 | 0.00 | 0.76 |
December | 0.103975E+10 | 0.00 | 0.00 | 4047749.97 | 0.00 | 0.227930E+10 | 0.146664E+10 | 0.00 | 0.57 |
Annual Sum or Average | 0.802199E+10 | 0.556706E+09 | 0.00 | 68395101.21 | 45811629.32 | 0.105094E+11 | 0.177778E+11 | 0.00 | 0.72 |
Minimum of Months | 0.170907E+09 | 0.00 | 0.00 | 1455853.38 | 0.00 | 715808.07 | 0.388070E+09 | 0.00 | 0.49 |
Maximum of Months | 0.104774E+10 | 0.197211E+09 | 0.00 | 11772220.05 | 21666404.03 | 0.227930E+10 | 0.322446E+10 | 0.00 | 1.22 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_BOT_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.780917E+09 | 0.00 | 0.00 | 472214.07 | 0.00 | 0.677468E+09 | 0.194794E+09 | 0.00 | 0.29 |
February | 0.673186E+09 | 0.00 | 0.00 | 594101.54 | 0.00 | 0.716208E+09 | 0.312827E+09 | 0.00 | 0.33 |
March | 0.713779E+09 | 0.00 | 0.00 | 1717162.14 | 0.00 | 0.455802E+09 | 0.764712E+09 | 0.00 | 0.56 |
April | 0.719196E+09 | 0.00 | 0.00 | 1503781.53 | 0.00 | 0.188630E+09 | 0.618119E+09 | 0.00 | 0.47 |
May | 0.323086E+09 | 671251.89 | 0.00 | 3797751.45 | 267900.34 | 7097170.51 | 0.125074E+10 | 0.00 | 0.79 |
June | 73326582.30 | 0.137520E+09 | 0.00 | 4664271.93 | 3634503.67 | 0.00 | 0.591900E+09 | 0.00 | 0.92 |
July | 64441220.69 | 0.146491E+09 | 0.00 | 3414177.50 | 10728446.83 | 0.00 | 0.434752E+09 | 0.00 | 0.82 |
August | 79286702.31 | 0.118991E+09 | 0.00 | 5986236.20 | 3244132.91 | 0.00 | 0.793256E+09 | 0.00 | 0.94 |
September | 0.162749E+09 | 19484602.32 | 0.00 | 6172696.26 | 1254159.90 | 0.00 | 0.118324E+10 | 0.00 | 1.05 |
October | 0.507903E+09 | 0.00 | 0.00 | 3600641.80 | 0.00 | 0.219125E+09 | 0.119828E+10 | 0.00 | 0.64 |
November | 0.836969E+09 | 0.00 | 0.00 | 1145946.77 | 0.00 | 0.293908E+09 | 0.499795E+09 | 0.00 | 0.39 |
December | 0.726254E+09 | 0.00 | 0.00 | 309161.63 | 0.00 | 0.979862E+09 | 0.147413E+09 | 0.00 | 0.31 |
Annual Sum or Average | 0.566109E+10 | 0.423159E+09 | 0.00 | 33378142.82 | 19129143.65 | 0.353810E+10 | 0.798983E+10 | 0.00 | 0.63 |
Minimum of Months | 64441220.69 | 0.00 | 0.00 | 309161.63 | 0.00 | 0.00 | 0.147413E+09 | 0.00 | 0.29 |
Maximum of Months | 0.836969E+09 | 0.146491E+09 | 0.00 | 6172696.26 | 10728446.83 | 0.979862E+09 | 0.125074E+10 | 0.00 | 1.05 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_3
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.124819E+10 | 0.00 | 0.00 | 24059.58 | 0.00 | 0.135255E+10 | 23386178.05 | 0.00 | 0.29 |
February | 0.117499E+10 | 0.00 | 0.00 | 11843.71 | 0.00 | 0.127700E+10 | 8107669.64 | 0.00 | 0.29 |
March | 0.142404E+10 | 0.00 | 0.00 | 852446.36 | 0.00 | 0.713630E+09 | 0.429715E+09 | 0.00 | 0.40 |
April | 0.135558E+10 | 0.00 | 0.00 | 1102398.79 | 0.00 | 0.300605E+09 | 0.553339E+09 | 0.00 | 0.40 |
May | 0.615996E+09 | 627142.33 | 0.00 | 5002280.28 | 361030.57 | 11086664.96 | 0.179181E+10 | 0.00 | 0.72 |
June | 0.105723E+09 | 0.130626E+09 | 0.00 | 6387209.25 | 10981787.10 | 0.00 | 0.931621E+09 | 0.00 | 0.81 |
July | 98700249.50 | 0.168760E+09 | 0.00 | 5325182.82 | 22821332.92 | 0.00 | 0.645637E+09 | 0.00 | 0.74 |
August | 0.160312E+09 | 0.117881E+09 | 0.00 | 6893418.11 | 6557481.09 | 0.00 | 0.102561E+10 | 0.00 | 0.73 |
September | 0.368483E+09 | 19965633.79 | 0.00 | 5378188.85 | 3831354.63 | 358725.18 | 0.106841E+10 | 0.00 | 0.67 |
October | 0.129061E+10 | 0.00 | 0.00 | 1209147.80 | 0.00 | 0.489264E+09 | 0.506709E+09 | 0.00 | 0.39 |
November | 0.137222E+10 | 0.00 | 0.00 | 331527.75 | 0.00 | 0.909148E+09 | 0.171325E+09 | 0.00 | 0.32 |
December | 0.102842E+10 | 0.00 | 0.00 | 826.36 | 0.00 | 0.211399E+10 | 5376120.44 | 0.00 | 0.32 |
Annual Sum or Average | 0.102433E+11 | 0.437861E+09 | 0.00 | 32518529.67 | 44552986.32 | 0.716763E+10 | 0.716104E+10 | 0.00 | 0.51 |
Minimum of Months | 98700249.50 | 0.00 | 0.00 | 826.36 | 0.00 | 0.00 | 5376120.44 | 0.00 | 0.29 |
Maximum of Months | 0.142404E+10 | 0.168760E+09 | 0.00 | 6893418.11 | 22821332.92 | 0.211399E+10 | 0.179181E+10 | 0.00 | 0.81 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_2
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.716252E+09 | 0.00 | 0.00 | 692208.49 | 0.00 | 0.575855E+09 | 0.296960E+09 | 0.00 | 0.28 |
February | 0.582568E+09 | 0.00 | 0.00 | 1237585.37 | 0.00 | 0.557760E+09 | 0.581681E+09 | 0.00 | 0.34 |
March | 0.608394E+09 | 0.00 | 0.00 | 3342287.58 | 0.00 | 0.289625E+09 | 0.159164E+10 | 0.00 | 0.67 |
April | 0.533097E+09 | 0.00 | 0.00 | 3243259.13 | 0.00 | 0.136095E+09 | 0.156195E+10 | 0.00 | 0.70 |
May | 0.220925E+09 | 504864.86 | 0.00 | 6448083.57 | 228434.66 | 1468590.66 | 0.244652E+10 | 0.00 | 1.22 |
June | 30439922.38 | 0.101011E+09 | 0.00 | 8356825.29 | 5694215.72 | 0.00 | 0.144965E+10 | 0.00 | 1.50 |
July | 30688093.51 | 0.146286E+09 | 0.00 | 7111399.76 | 8256313.12 | 0.00 | 0.828789E+09 | 0.00 | 1.23 |
August | 67798047.40 | 99509407.90 | 0.00 | 9498608.02 | 3661169.35 | 0.00 | 0.173183E+10 | 0.00 | 1.47 |
September | 0.149643E+09 | 17631360.55 | 0.00 | 7589329.38 | 2310694.20 | 226975.97 | 0.165671E+10 | 0.00 | 1.28 |
October | 0.528909E+09 | 0.00 | 0.00 | 3315436.26 | 0.00 | 0.298547E+09 | 0.124936E+10 | 0.00 | 0.61 |
November | 0.706767E+09 | 0.00 | 0.00 | 1251159.34 | 0.00 | 0.411768E+09 | 0.508558E+09 | 0.00 | 0.37 |
December | 0.602934E+09 | 0.00 | 0.00 | 233689.57 | 0.00 | 0.106698E+10 | 0.124101E+09 | 0.00 | 0.28 |
Annual Sum or Average | 0.477842E+10 | 0.364943E+09 | 0.00 | 52319871.76 | 20150827.05 | 0.333833E+10 | 0.140278E+11 | 0.00 | 0.83 |
Minimum of Months | 30439922.38 | 0.00 | 0.00 | 233689.57 | 0.00 | 0.00 | 0.124101E+09 | 0.00 | 0.28 |
Maximum of Months | 0.716252E+09 | 0.146286E+09 | 0.00 | 9498608.02 | 8256313.12 | 0.106698E+10 | 0.244652E+10 | 0.00 | 1.50 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_1
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.107964E+10 | 0.00 | 0.00 | 9928886.63 | 0.00 | 0.538559E+09 | 0.421974E+10 | 0.00 | 0.81 |
February | 0.863238E+09 | 0.00 | 0.00 | 9455308.68 | 0.00 | 0.642216E+09 | 0.418515E+10 | 0.00 | 0.79 |
March | 0.965675E+09 | 0.00 | 0.00 | 9051747.93 | 0.00 | 0.493974E+09 | 0.414222E+10 | 0.00 | 1.06 |
April | 0.105008E+10 | 0.00 | 0.00 | 4877585.98 | 0.00 | 0.242350E+09 | 0.233187E+10 | 0.00 | 0.77 |
May | 0.524574E+09 | 900913.96 | 0.00 | 7477876.05 | 360429.44 | 13166370.21 | 0.267820E+10 | 0.00 | 0.98 |
June | 0.146135E+09 | 0.149192E+09 | 0.00 | 7050217.73 | 11139830.71 | 0.00 | 0.904318E+09 | 0.00 | 0.88 |
July | 0.113827E+09 | 0.231748E+09 | 0.00 | 5979909.95 | 14381627.19 | 0.00 | 0.657743E+09 | 0.00 | 0.82 |
August | 0.147561E+09 | 0.184849E+09 | 0.00 | 10940014.52 | 4841292.35 | 0.00 | 0.146236E+10 | 0.00 | 1.03 |
September | 0.277215E+09 | 41166750.01 | 0.00 | 12526048.89 | 3376856.74 | 358127.89 | 0.228246E+10 | 0.00 | 1.30 |
October | 0.708582E+09 | 0.00 | 0.00 | 13809828.98 | 0.00 | 0.462447E+09 | 0.441698E+10 | 0.00 | 1.20 |
November | 0.965255E+09 | 0.00 | 0.00 | 11195008.31 | 0.00 | 0.437653E+09 | 0.449876E+10 | 0.00 | 0.98 |
December | 0.103983E+10 | 0.00 | 0.00 | 7593693.67 | 0.00 | 0.104379E+10 | 0.321792E+10 | 0.00 | 0.75 |
Annual Sum or Average | 0.788160E+10 | 0.607856E+09 | 0.00 | 0.109886E+09 | 34100036.43 | 0.387451E+10 | 0.349977E+11 | 0.00 | 0.95 |
Minimum of Months | 0.113827E+09 | 0.00 | 0.00 | 4877585.98 | 0.00 | 0.00 | 0.657743E+09 | 0.00 | 0.75 |
Maximum of Months | 0.107964E+10 | 0.231748E+09 | 0.00 | 13809828.98 | 14381627.19 | 0.104379E+10 | 0.449876E+10 | 0.00 | 1.30 |
Report: MechanicalVentilationLoadsMonthly
For: PERIMETER_MID_ZN_4
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] | ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] | ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] | ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach] | |
January | 0.822595E+09 | 0.00 | 0.00 | 982765.77 | 0.00 | 0.624362E+09 | 0.516666E+09 | 0.00 | 0.39 |
February | 0.705098E+09 | 0.00 | 0.00 | 1266868.50 | 0.00 | 0.638003E+09 | 0.676447E+09 | 0.00 | 0.41 |
March | 0.772893E+09 | 0.00 | 0.00 | 2981734.53 | 0.00 | 0.377189E+09 | 0.134952E+10 | 0.00 | 0.76 |
April | 0.724818E+09 | 0.00 | 0.00 | 2680311.28 | 0.00 | 0.170433E+09 | 0.125173E+10 | 0.00 | 0.73 |
May | 0.302434E+09 | 854091.17 | 0.00 | 5748881.27 | 227971.21 | 9115319.60 | 0.196736E+10 | 0.00 | 1.14 |
June | 84226844.30 | 0.160868E+09 | 0.00 | 5777148.96 | 2864079.55 | 0.00 | 0.656325E+09 | 0.00 | 1.07 |
July | 67841498.19 | 0.180478E+09 | 0.00 | 4122536.31 | 8486847.74 | 0.00 | 0.479743E+09 | 0.00 | 0.95 |
August | 92721493.62 | 0.137254E+09 | 0.00 | 6914132.51 | 2262483.49 | 0.00 | 0.816898E+09 | 0.00 | 1.01 |
September | 0.199958E+09 | 25139097.04 | 0.00 | 5999957.45 | 946326.94 | 1886453.52 | 0.110454E+10 | 0.00 | 1.05 |
October | 0.619216E+09 | 0.00 | 0.00 | 3798019.40 | 0.00 | 0.312187E+09 | 0.138185E+10 | 0.00 | 0.76 |
November | 0.803662E+09 | 0.00 | 0.00 | 1437155.56 | 0.00 | 0.464413E+09 | 0.694096E+09 | 0.00 | 0.47 |
December | 0.709713E+09 | 0.00 | 0.00 | 494106.08 | 0.00 | 0.114083E+10 | 0.270107E+09 | 0.00 | 0.38 |
Annual Sum or Average | 0.590518E+10 | 0.504593E+09 | 0.00 | 42203617.61 | 14787708.93 | 0.373841E+10 | 0.111653E+11 | 0.00 | 0.76 |
Minimum of Months | 67841498.19 | 0.00 | 0.00 | 494106.08 | 0.00 | 0.00 | 0.270107E+09 | 0.00 | 0.38 |
Maximum of Months | 0.822595E+09 | 0.180478E+09 | 0.00 | 6914132.51 | 8486847.74 | 0.114083E+10 | 0.196736E+10 | 0.00 | 1.14 |
Report: HeatEmissionsReportMonthly
For: Environment
Timestamp: 2023-10-16 08:32:02
Custom Monthly ReportSITE TOTAL SURFACE HEAT EMISSION TO AIR [J] | SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] | SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] | AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] | HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J] | |
January | 0.245909E+12 | 0.119456E+11 | 0.00 | 0.170485E+12 | 0.135719E+11 |
February | 0.303029E+12 | 0.159700E+11 | 0.00 | 0.155426E+12 | 0.113308E+11 |
March | 0.367051E+12 | 0.163351E+11 | 0.00 | 0.182450E+12 | 0.172921E+11 |
April | 0.379867E+12 | 0.161062E+11 | 0.00 | 0.179838E+12 | 0.140145E+11 |
May | 0.443342E+12 | 0.867238E+10 | 0.00 | 0.207956E+12 | 0.532461E+11 |
June | 0.461274E+12 | 0.263282E+10 | 0.00 | 0.127154E+12 | 0.198812E+12 |
July | 0.431032E+12 | 0.195098E+10 | 0.00 | 0.101187E+12 | 0.200345E+12 |
August | 0.429086E+12 | 0.247250E+10 | 0.00 | 0.109158E+12 | 0.193437E+12 |
September | 0.326452E+12 | 0.517523E+10 | 0.00 | 0.162615E+12 | 0.127707E+12 |
October | 0.290114E+12 | 0.129991E+11 | 0.00 | 0.207380E+12 | 0.334739E+11 |
November | 0.258500E+12 | 0.127439E+11 | 0.00 | 0.186639E+12 | 0.159790E+11 |
December | 0.206200E+12 | 0.201873E+11 | 0.00 | 0.159365E+12 | 0.132691E+11 |
Annual Sum or Average | 0.414185E+13 | 0.127191E+12 | 0.00 | 0.194965E+13 | 0.892479E+12 |
Minimum of Months | 0.206200E+12 | 0.195098E+10 | 0.00 | 0.101187E+12 | 0.113308E+11 |
Maximum of Months | 0.461274E+12 | 0.201873E+11 | 0.00 | 0.207956E+12 | 0.200345E+12 |