Table of Contents

Program Version:EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:27

Tabular Output Report in Format: HTML

Building: OfficeSmall

Environment: RUNPERIOD 1 ** Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930

Simulation Timestamp: 2023-10-16 08:27:23


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [GJ] Energy Per Total Building Area [MJ/m2] Energy Per Conditioned Building Area [MJ/m2]
Total Site Energy 143.75 281.23 281.23
Net Site Energy 143.75 281.23 281.23
Total Source Energy 453.71 887.62 887.62
Net Source Energy 453.71 887.62 887.62


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 511.16
Net Conditioned Building Area 511.16
Unconditioned Building Area 0.00


End Uses

Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating 7.57 0.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 7.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 26.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 10.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 48.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 18.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 24.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 143.01 0.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Note: Electricity appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating General 7.57 0.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 7.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 26.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 10.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 48.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 18.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 24.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.16
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.16
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Space Type

Space Type Electricity [GJ] Natural Gas [GJ] Gasoline [GJ] Diesel [GJ] Coal [GJ] Fuel Oil No 1 [GJ] Fuel Oil No 2 [GJ] Propane [GJ] Other Fuel 1 [GJ] Other Fuel 2 [GJ] District Cooling [GJ] District Heating [GJ] Water [m3]
Heating Unassigned 7.57 0.74 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling Unassigned 7.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting GENERAL 26.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting Unassigned 10.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment GENERAL 48.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Unassigned 18.43 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems Unassigned 24.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 58.31
Refrigeration Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators Unassigned 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 71.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 113.42 1.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11
Other 94.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 279.77 1.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11


Utility Use Per Total Floor Area

Electricity Intensity [MJ/m2] Natural Gas Intensity [MJ/m2] Gasoline Intensity [MJ/m2] Diesel Intensity [MJ/m2] Coal Intensity [MJ/m2] Fuel Oil No 1 Intensity [MJ/m2] Fuel Oil No 2 Intensity [MJ/m2] Propane Intensity [MJ/m2] Other Fuel 1 Intensity [MJ/m2] Other Fuel 2 Intensity [MJ/m2] District Cooling Intensity [MJ/m2] District Heating Intensity [MJ/m2] Water Intensity [m3/m2]
Lighting 71.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 113.42 1.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11
Other 94.48 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 279.77 1.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.11


Electric Loads Satisfied

Electricity [GJ] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 143.009 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 143.009 100.00
     
Total On-Site and Utility Electric Sources 143.009 100.00
Total Electricity End Uses 143.009 100.00


On-Site Thermal Sources

Heat [GJ] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 58.31 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 58.31 100.00
Total Water End Uses 58.31 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.56
Tolerance for Zone Cooling Setpoint Not Met Time 0.56


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 21.00
Time Setpoint Not Met During Occupied Cooling 2.50
Time Not Comfortable Based on Simple ASHRAE 55-2004 1541.00


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Source Energy End Use Components Summary
Component Sizing Summary
Surface Shadowing Summary
Adaptive Comfort Summary
Initialization Summary
Annual Heat Emissions Summary
Climatic Data Summary
Envelope Summary
Shading Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
Coil Sizing Details
System Summary
Outdoor Air Summary
Outdoor Air Details
Object Count Summary
Energy Meters
Sensible Heat Gain Summary
Standard 62.1 Summary
LEED Summary
Annual Thermal Resilience Summary
Annual CO2 Resilience Summary
Annual Visual Resilience Summary

NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019

| Environment |

NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

| Environment |

NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICESMALL

| Environment |

NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

| Environment |

NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 4C

| Environment |

NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_SEATTLE

| Environment |

ZoneCoolingSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ZoneHeatingSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ZoneElectricSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

SpaceGainsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

PeakSpaceGainsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

SpaceGainComponentsAtCoolingPeakMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

EnergyConsumptionElectricityNaturalGasMonthly

| Meter |

EndUseEnergyConsumptionElectricityMonthly

| Meter |

EndUseEnergyConsumptionNaturalGasMonthly

| Meter |

PeakEnergyEndUseElectricityPart1Monthly

| Meter |

PeakEnergyEndUseElectricityPart2Monthly

| Meter |

ElectricComponentsOfPeakDemandMonthly

| Meter |

PeakEnergyEndUseNaturalGasMonthly

| Meter |

SetpointsNotMetWithTemperaturesMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

ComfortReportSimple55Monthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

OccupantComfortDataSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

DXReportMonthly

| PSZ-AC:1 HP COOLING COIL | PSZ-AC:2 HP COOLING COIL | PSZ-AC:3 HP COOLING COIL | PSZ-AC:4 HP COOLING COIL | PSZ-AC:5 HP COOLING COIL |

WindowReportMonthly

| PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR | PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |

WindowEnergyReportMonthly

| PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR | PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 | PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |

WindowZoneSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

WindowEnergyZoneSummaryMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

AverageOutdoorConditionsMonthly

| Environment |

OutdoorConditionsMaximumDryBulbMonthly

| Environment |

OutdoorConditionsMinimumDryBulbMonthly

| Environment |

OutdoorConditionsMaximumWetBulbMonthly

| Environment |

OutdoorConditionsMaximumDewPointMonthly

| Environment |

OutdoorGroundConditionsMonthly

| Environment |

WaterHeaterReportMonthly

| SWHSYS1 WATER HEATER |

DaylightingReportMonthly

| PERIMETER_ZN_1_DAYLCTRL | PERIMETER_ZN_2_DAYLCTRL | PERIMETER_ZN_3_DAYLCTRL | PERIMETER_ZN_4_DAYLCTRL |

CoilReportMonthly

| PSZ-AC:1 HEATING COIL | PSZ-AC:2 HEATING COIL | PSZ-AC:3 HEATING COIL | PSZ-AC:4 HEATING COIL | PSZ-AC:5 HEATING COIL | PSZ-AC:1_SUPPHEATCOIL | PSZ-AC:2_SUPPHEATCOIL | PSZ-AC:3_SUPPHEATCOIL | PSZ-AC:4_SUPPHEATCOIL | PSZ-AC:5_SUPPHEATCOIL | PSZ-AC:1 HP COOLING COIL | PSZ-AC:2 HP COOLING COIL | PSZ-AC:3 HP COOLING COIL | PSZ-AC:4 HP COOLING COIL | PSZ-AC:5 HP COOLING COIL |

PlantLoopDemandReportMonthly

| SWHSYS1 |

FanReportMonthly

| PSZ-AC:1 FAN | PSZ-AC:2 FAN | PSZ-AC:3 FAN | PSZ-AC:4 FAN | PSZ-AC:5 FAN |

PumpReportMonthly

| SWHSYS1 PUMP |

CondLoopDemandReportMonthly

| SWHSYS1 |

ZoneTemperatureOscillationReportMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 | ATTIC |

AirLoopSystemEnergyAndWaterUseMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

AirLoopSystemComponentLoadsMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

AirLoopSystemComponentEnergyUseMonthly

| PSZ-AC:1 | PSZ-AC:2 | PSZ-AC:3 | PSZ-AC:4 | PSZ-AC:5 |

MechanicalVentilationLoadsMonthly

| CORE_ZN | PERIMETER_ZN_1 | PERIMETER_ZN_2 | PERIMETER_ZN_3 | PERIMETER_ZN_4 |

HeatEmissionsReportMonthly

| Environment |

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

General

Value
Program Version and Build EnergyPlus, Version 22.1.0-ed759b17ee, YMD=2023.10.16 08:27
RunPeriod RUNPERIOD 1
Weather File Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930
Latitude [deg] 47.47
Longitude [deg] -122.3
Elevation [m] 122.00
Time Zone -8.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Above Ground Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Window Opening Area [m2] 59.65 16.72 11.15 20.63 11.15
Gross Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80
Above Ground Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Above Ground Wall Area [m2] 281.51 84.45 56.30 84.45 56.30
Window Opening Area [m2] 59.65 16.72 11.15 20.63 11.15
Gross Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80
Above Ground Window-Wall Ratio [%] 21.19 19.80 19.80 24.43 19.80


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 598.76
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
CORE_ZN 149.66 Yes Yes 456.46 1.00 0.00 0.00 0.00 0.00 6.9815 18.58 6.7800
PERIMETER_ZN_1 113.45 Yes Yes 346.02 1.00 84.45 0.00 20.63 20.63 6.9815 18.58 6.7800
PERIMETER_ZN_2 67.30 Yes Yes 205.26 1.00 56.30 0.00 11.15 11.15 6.9815 18.58 6.7800
PERIMETER_ZN_3 113.45 Yes Yes 346.02 1.00 84.45 0.00 16.72 16.72 6.9815 18.58 6.7800
PERIMETER_ZN_4 67.30 Yes Yes 205.26 1.00 56.30 0.00 11.15 11.15 6.9815 18.58 6.7800
ATTIC 567.98 No No 720.19 1.00 0.00 0.00 0.00 0.00 0.0000   0.0000
Total 511.16     1559.03   281.51 0.00 59.65 59.65 6.9815 18.58 6.7800
Conditioned Total 511.16     1559.03   281.51 0.00 59.65 59.65 6.9815 18.58 6.7800
Unconditioned Total 0.00     0.00   0.00 0.00 0.00 0.00      
Not Part of Total 567.98     720.19   0.00 0.00 0.00 0.00 0.0000   0.0000


Space Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Multipliers Zone Name Space Type Radiant/Solar Enclosure Name Lighting [W/m2] People [m2 per person] Plug and Process [W/m2] Tags
CORE_ZN 149.66 Yes Yes 1.00 CORE_ZN GENERAL CORE_ZN 6.9815 18.58 6.7800  
PERIMETER_ZN_1 113.45 Yes Yes 1.00 PERIMETER_ZN_1 GENERAL PERIMETER_ZN_1 6.9815 18.58 6.7800  
PERIMETER_ZN_2 67.30 Yes Yes 1.00 PERIMETER_ZN_2 GENERAL PERIMETER_ZN_2 6.9815 18.58 6.7800  
PERIMETER_ZN_3 113.45 Yes Yes 1.00 PERIMETER_ZN_3 GENERAL PERIMETER_ZN_3 6.9815 18.58 6.7800  
PERIMETER_ZN_4 67.30 Yes Yes 1.00 PERIMETER_ZN_4 GENERAL PERIMETER_ZN_4 6.9815 18.58 6.7800  
ATTIC 567.98 No No 1.00 ATTIC GENERAL ATTIC 0.0000 0.00 0.0000  
Total 511.16             6.9815 9.29 6.7800  
Conditioned Total 511.16             6.9815 9.29 6.7800  
Unconditioned Total 0.00             0.0000 0.00 0.0000  
Not Part of Total 567.98             0.0000 0.00 0.0000  


Space Type Summary

Total Area [m2] Conditioned Area [m2] Unconditioned Area [m2] Not Part of Total Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
GENERAL 511.16 511.16 0.00 567.98 6.9815 18.58 6.7800
Total 511.16 511.16 0.00 567.98      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Time of Peak 26-DEC-08:09 26-DEC-06:19 - - - - - - - - - - 02-JAN-12:09
Heating 7517.36 19354.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 2528.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 3325.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 1612.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 2738.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 17721.59 19354.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] Steam [W] Water [m3/s]
Heating General 7517.36 19354.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting LightsWired 2528.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment MiscPlug 3325.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans General 1612.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Water Heater 2738.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Source Energy End Use Components Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Values gathered over 8760.00 hours



Source Energy End Use Components Summary

Source Electricity [GJ] Source Natural Gas [GJ] Source Gasoline [GJ] Source Diesel [GJ] Source Coal [GJ] Source Fuel Oil No 1 [GJ] Source Fuel Oil No 2 [GJ] Source Propane [GJ] Source Other Fuel 1 [GJ] Source Other Fuel 2 [GJ] Source District Cooling [GJ] Source District Heating [GJ]
Heating 23.98 0.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 22.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 84.63 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 31.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 152.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 58.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 78.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 452.91 0.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Source Energy End Use Components Per Conditioned Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 46.91 1.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 44.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 62.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 299.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 114.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 153.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 886.04 1.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Source Energy End Use Components Per Total Floor Area

Source Electricity [MJ/m2] Source Natural Gas [MJ/m2] Source Gasoline [MJ/m2] Source Diesel [MJ/m2] Source Coal [MJ/m2] Source Fuel Oil No 1 [MJ/m2] Source Fuel Oil No 2 [MJ/m2] Source Propane [MJ/m2] Source Other Fuel 1 [MJ/m2] Source Other Fuel 2 [MJ/m2] Source District Cooling [MJ/m2] Source District Heating [MJ/m2]
Heating 46.91 1.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling 44.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting 165.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 62.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 299.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 114.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 153.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Total Source Energy End Use Components 886.04 1.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

AirTerminal:SingleDuct:ConstantVolume:NoReheat

Design Size Maximum Air Flow Rate [m3/s]
CORE_ZN DIRECT AIR 0.279779
PERIMETER_ZN_1 DIRECT AIR 0.404782
PERIMETER_ZN_2 DIRECT AIR 0.235322
PERIMETER_ZN_3 DIRECT AIR 0.237800
PERIMETER_ZN_4 DIRECT AIR 0.282072
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC

Sum of Air Terminal Maximum Heating Flow Rates [m3/s] Sum of Air Terminal Minimum Heating Flow Rates [m3/s] Sum of Air Terminal Maximum Flow Rates [m3/s] Adjusted Heating Design Air Flow Rate [m3/s] Adjusted Cooling Design Air Flow Rate [m3/s] Adjusted Main Design Air Flow Rate [m3/s] User Heating Air Flow Ratio [] Calculated Heating Air Flow Ratio [] Design Supply Air Flow Rate [m3/s]
PSZ-AC:1 0.279779 0.279779 0.279779 0.279779 0.279779 0.279779 1.00 1.00 0.279779
PSZ-AC:2 0.404782 0.404782 0.404782 0.404782 0.404782 0.404782 1.00 1.00 0.404782
PSZ-AC:3 0.235322 0.235322 0.235322 0.235322 0.235322 0.235322 1.00 1.00 0.235322
PSZ-AC:4 0.237800 0.237800 0.237800 0.237800 0.237800 0.237800 1.00 1.000000 0.237800
PSZ-AC:5 0.282072 0.282072 0.282072 0.282072 0.282072 0.282072 1.00 1.00 0.282072
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Controller:OutdoorAir

Maximum Outdoor Air Flow Rate [m3/s] Minimum Outdoor Air Flow Rate [m3/s]
PSZ-AC:1_OA_CONTROLLER 0.279779 0.064622
PSZ-AC:2_OA_CONTROLLER 0.404782 0.048988
PSZ-AC:3_OA_CONTROLLER 0.235322 0.029060
PSZ-AC:4_OA_CONTROLLER 0.237800 0.048988
PSZ-AC:5_OA_CONTROLLER 0.282072 0.029060
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Cooling:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Total Cooling Capacity [W] Design Size Gross Rated Sensible Heat Ratio
PSZ-AC:1 HP COOLING COIL 0.279779 4784.84 0.800861
PSZ-AC:2 HP COOLING COIL 0.404782 6700.57 0.800655
PSZ-AC:3 HP COOLING COIL 0.235322 3895.42 0.800655
PSZ-AC:4 HP COOLING COIL 0.237800 4014.40 0.800514
PSZ-AC:5 HP COOLING COIL 0.282072 4669.29 0.800655
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

AirLoopHVAC:UnitaryHeatPump:AirToAir

Supply Air Flow Rate [m3/s] Supply Air Flow Rate During Heating Operation [m3/s] Supply Air Flow Rate During Cooling Operation [m3/s] Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] Nominal Heating Capacity [W] Nominal Cooling Capacity [W] Maximum Supply Air Temperature from Supplemental Heater [C] Supplemental Heating Coil Nominal Capacity [W] Fraction of Supply Air Flow That Goes Through the Controlling Zone
PSZ-AC:1_UNITARY_PACKAGE_DX 0.279779 0.279779 0.279779 0.279779 4784.84 4784.84 40.00 3406.87 1.00
PSZ-AC:2_UNITARY_PACKAGE_DX 0.404782 0.404782 0.404782 0.404782 6700.57 6700.57 40.00 4463.50 1.00
PSZ-AC:3_UNITARY_PACKAGE_DX 0.235322 0.235322 0.235322 0.235322 3895.42 3895.42 40.00 2766.65 1.00
PSZ-AC:4_UNITARY_PACKAGE_DX 0.237800 0.237800 0.237800 0.237800 4014.40 4014.40 40.00 4446.43 1.00
PSZ-AC:5_UNITARY_PACKAGE_DX 0.282072 0.282072 0.282072 0.282072 4669.29 4669.29 40.00 2758.94 1.00
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Fan:OnOff

Design Size Maximum Flow Rate [m3/s]
PSZ-AC:1 FAN 0.279779
PSZ-AC:2 FAN 0.404782
PSZ-AC:3 FAN 0.235322
PSZ-AC:4 FAN 0.237800
PSZ-AC:5 FAN 0.282072
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:DX:SingleSpeed

Design Size Rated Air Flow Rate [m3/s] Design Size Gross Rated Heating Capacity [W]
PSZ-AC:1 HEATING COIL 0.279779 4784.84
PSZ-AC:2 HEATING COIL 0.404782 6700.57
PSZ-AC:3 HEATING COIL 0.235322 3895.42
PSZ-AC:4 HEATING COIL 0.237800 4014.40
PSZ-AC:5 HEATING COIL 0.282072 4669.29
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Coil:Heating:Fuel

Design Size Nominal Capacity [W]
PSZ-AC:1_SUPPHEATCOIL 3406.87
PSZ-AC:2_SUPPHEATCOIL 4463.50
PSZ-AC:3_SUPPHEATCOIL 2766.65
PSZ-AC:4_SUPPHEATCOIL 4446.43
PSZ-AC:5_SUPPHEATCOIL 2758.94
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

PlantLoop

Maximum Loop Flow Rate [m3/s] Plant Loop Volume [m3]
SWHSYS1 0.000004 0.000486
User-Specified values were used. Design Size values were used if no User-Specified values were provided.

Pump:ConstantSpeed

Design Flow Rate [m3/s] Design Power Consumption [W]
SWHSYS1 PUMP 0.000004 0.000000
User-Specified values were used. Design Size values were used if no User-Specified values were provided.


Table of Contents

Report: Surface Shadowing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces

Possible Shadow Receivers
PERIMETER_ZN_1_WALL_SOUTH ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_EAST |
PERIMETER_ZN_2_WALL_EAST ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_EAST | ATTIC_SOFFIT_NORTH |
PERIMETER_ZN_3_WALL_NORTH ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_EAST | ATTIC_SOFFIT_NORTH |
PERIMETER_ZN_4_WALL_WEST ATTIC_SOFFIT_WEST | ATTIC_SOFFIT_SOUTH | ATTIC_SOFFIT_NORTH |


Subsurfaces (Windows and Doors) that may be Shadowed by Surfaces

Possible Shadow Receivers
PERIMETER_ZN_1_WALL_SOUTH PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 | PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 | PERIMETER_ZN_1_WALL_SOUTH_DOOR |
PERIMETER_ZN_2_WALL_EAST PERIMETER_ZN_2_WALL_EAST_WINDOW_4 | PERIMETER_ZN_2_WALL_EAST_WINDOW_3 | PERIMETER_ZN_2_WALL_EAST_WINDOW_2 | PERIMETER_ZN_2_WALL_EAST_WINDOW_1 |
PERIMETER_ZN_3_WALL_NORTH PERIMETER_ZN_3_WALL_NORTH_DOOR1 | PERIMETER_ZN_3_WALL_NORTH_DOOR2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 | PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 |
PERIMETER_ZN_4_WALL_WEST PERIMETER_ZN_4_WALL_WEST_WINDOW_4 | PERIMETER_ZN_4_WALL_WEST_WINDOW_3 | PERIMETER_ZN_4_WALL_WEST_WINDOW_2 | PERIMETER_ZN_4_WALL_WEST_WINDOW_1 |



Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Initialization Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Version

Version ID
1 22.1


Timesteps per Hour

#TimeSteps Minutes per TimeStep {minutes}
1 6 10


System Convergence Limits

Minimum System TimeStep {minutes} Max HVAC Iterations Minimum Plant Iterations Maximum Plant Iterations
1 1 20 2 8


Simulation Control

Do Zone Sizing Do System Sizing Do Plant Sizing Do Design Days Do Weather Simulation Do HVAC Sizing Simulation
1 Yes Yes Yes No Yes No


Performance Precision Tradeoffs

Use Coil Direct Simulation Zone Radiant Exchange Algorithm Override Mode Number of Timestep In Hour Force Euler Method Minimum Number of Warmup Days Force Suppress All Begin Environment Resets Minimum System Timestep MaxZoneTempDiff MaxAllowedDelTemp
1 No ScriptF Normal 6 No 1 No 1.0 0.300 2.0000E-003


Output Reporting Tolerances

Tolerance for Time Heating Setpoint Not Met Tolerance for Zone Cooling Setpoint Not Met Time
1 0.556 0.556


Site:GroundTemperature:BuildingSurface

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00 18.00


Site:GroundTemperature:FCfactorMethod

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 11.40 8.10 5.40 4.50 5.80 8.30 10.90 13.00 15.60 17.70 18.80 15.10


Site:GroundTemperature:Shallow

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00


Site:GroundTemperature:Deep

Jan{C} Feb{C} Mar{C} Apr{C} May{C} Jun{C} Jul{C} Aug{C} Sep{C} Oct{C} Nov{C} Dec{C}
1 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00


Site:GroundReflectance

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:SnowModifier

Normal Daylighting {dimensionless}
1 1.000 1.000


Site:GroundReflectance:Snow

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Site:GroundReflectance:Snow:Daylighting

Jan{dimensionless} Feb{dimensionless} Mar{dimensionless} Apr{dimensionless} May{dimensionless} Jun{dimensionless} Jul{dimensionless} Aug{dimensionless} Sep{dimensionless} Oct{dimensionless} Nov{dimensionless} Dec{dimensionless}
1 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20


Environment:Weather Station

Wind Sensor Height Above Ground {m} Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Sensor Height Above Ground {m} Wind Speed Modifier Coefficient-Internal Temperature Modifier Coefficient-Internal
1 10.000 0.140 270.000 1.500 1.586 9.750E-003


Site:Location

Location Name Latitude {N+/S- Deg} Longitude {E+/W- Deg} Time Zone Number {GMT+/-} Elevation {m} Standard Pressure at Elevation {Pa} Standard RhoAir at Elevation
1 Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930 47.47 -122.32 -8.00 122.00 99868 1.1870


Site Water Mains Temperature Information

Calculation Method{} Water Mains Temperature Schedule Name{} Annual Average Outdoor Air Temperature{C} Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} Fixed Default Water Mains Temperature{C}
1 Correlation NA 11.22 14.30 NA


Building Information

Building Name North Axis {deg} Terrain Loads Convergence Tolerance Value Temperature Convergence Tolerance Value Solar Distribution Maximum Number of Warmup Days Minimum Number of Warmup Days
1 OfficeSmall 0.000 City 4.00000E-002 0.20000 FullInteriorAndExterior 25 6


Inside Convection Algorithm

Algorithm {Simple
TARP
CeilingDiffuser
AdaptiveConvectionAlgorithm}
1 TARP


Outside Convection Algorithm

Algorithm {SimpleCombined
TARP
MoWitt
DOE-2
AdaptiveConvectionAlgorithm}
1 TARP


Sky Radiance Distribution

Value {Anisotropic}
1 Anisotropic


Zone Air Solution Algorithm

Value {ThirdOrderBackwardDifference
AnalyticalSolution
EulerMethod}
1 ThirdOrderBackwardDifference


Zone Air Carbon Dioxide Balance Simulation

Simulation {Yes/No} Carbon Dioxide Concentration
1 No N/A


Zone Air Generic Contaminant Balance Simulation

Simulation {Yes/No} Generic Contaminant Concentration
1 No N/A


Zone Air Mass Flow Balance Simulation

Enforce Mass Balance



Adjust Zone Mixing and Return {AdjustMixingOnly
AdjustReturnOnly
AdjustMixingThenReturn
AdjustReturnThenMixing
None}
Adjust Zone Infiltration {AddInfiltration
AdjustInfiltration
None}

Infiltration Zones {MixingSourceZonesOnly
AllZones}


1 No N/A N/A N/A


HVACSystemRootFindingAlgorithm

Value {RegulaFalsi
Bisection
BisectionThenRegulaFalsi
RegulaFalsiThenBisection}
1 RegulaFalsi


Environment:Site Atmospheric Variation

Wind Speed Profile Exponent {} Wind Speed Profile Boundary Layer Thickness {m} Air Temperature Gradient Coefficient {K/m}
1 0.330 460.000 6.500000E-003


Surface Geometry

Starting Corner Vertex Input Direction Coordinate System Daylight Reference Point Coordinate System Rectangular (Simple) Surface Coordinate System
1 UpperLeftCorner Counterclockwise RelativeCoordinateSystem RelativeCoordinateSystem RelativeToZoneOrigin


Surface Heat Transfer Algorithm

Value {CTF - ConductionTransferFunction
EMPD - MoisturePenetrationDepthConductionTransferFunction
CondFD - ConductionFiniteDifference
HAMT - CombinedHeatAndMoistureFiniteElement} - Description
Inside Surface Max Temperature Limit{C}


Surface Convection Coefficient Lower Limit {W/m2-K}


Surface Convection Coefficient Upper Limit {W/m2-K}


1 CTF - ConductionTransferFunction 200 0.10 1000.0


Shading Summary

Number of Fixed Detached Shades Number of Building Detached Shades Number of Attached Shades
1 0 0 0


Zone Summary

Number of Zones Number of Zone Surfaces Number of SubSurfaces
1 6 71 23


Zone Information

Zone Name North Axis {deg} Origin X-Coordinate {m} Origin Y-Coordinate {m} Origin Z-Coordinate {m} Centroid X-Coordinate {m} Centroid Y-Coordinate {m} Centroid Z-Coordinate {m} Type Zone Multiplier Zone List Multiplier Minimum X {m} Maximum X {m} Minimum Y {m} Maximum Y {m} Minimum Z {m} Maximum Z {m} Ceiling Height {m} Volume {m3} Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} Floor Area {m2} Exterior Gross Wall Area {m2} Exterior Net Wall Area {m2} Exterior Window Area {m2} Number of Surfaces Number of SubSurfaces Number of Shading SubSurfaces Part of Total Building Area
1 CORE_ZN 0.0 0.00 0.00 0.00 13.85 9.23 1.53 1 1 1 5.00 22.69 5.00 13.46 0.00 3.05 3.05 456.46 TARP TARP 149.66 0.00 0.00 0.00 6 0 0 Yes
2 PERIMETER_ZN_1 0.0 0.00 0.00 0.00 13.85 2.21 1.53 1 1 1 0.00 27.69 0.00 5.00 0.00 3.05 3.05 346.02 TARP TARP 113.45 84.45 63.82 20.63 6 7 0 Yes
3 PERIMETER_ZN_2 0.0 0.00 0.00 0.00 25.64 9.23 1.53 1 1 1 22.69 27.69 0.00 18.46 0.00 3.05 3.05 205.27 TARP TARP 67.30 56.30 45.15 11.15 6 4 0 Yes
4 PERIMETER_ZN_3 0.0 0.00 0.00 0.00 13.85 16.25 1.53 1 1 1 0.00 27.69 13.46 18.46 0.00 3.05 3.05 346.02 TARP TARP 113.45 84.45 63.83 16.72 6 8 0 Yes
5 PERIMETER_ZN_4 0.0 0.00 0.00 0.00 2.05 9.23 1.53 1 1 1 0.00 5.00 0.00 18.46 0.00 3.05 3.05 205.27 TARP TARP 67.30 56.30 45.15 11.15 6 4 0 Yes
6 ATTIC 0.0 0.00 0.00 0.00 13.85 9.23 3.70 1 1 1 -0.60 28.29 -0.60 19.06 3.05 6.33 1.64 720.19 TARP TARP 567.98 0.00 0.00 0.00 13 0 0 No


Zone Internal Gains Nominal

Zone Name Floor Area {m2} # Occupants Area per Occupant {m2/person} Occupant per Area {person/m2} Interior Lighting {W/m2} Electric Load {W/m2} Gas Load {W/m2} Other Load {W/m2} Hot Water Eq {W/m2} Steam Equipment {W/m2} Sum Loads per Area {W/m2} Outdoor Controlled Baseboard Heat
1 CORE_ZN 149.66 8.1 18.581 5.382E-002 6.981 6.780 0.000 0.000 0.000 0.000 13.761 No
2 PERIMETER_ZN_1 113.45 6.1 18.581 5.382E-002 6.981 6.780 0.000 0.000 0.000 0.000 13.761 No
3 PERIMETER_ZN_2 67.30 3.6 18.581 5.382E-002 6.981 6.780 0.000 0.000 0.000 0.000 13.761 No
4 PERIMETER_ZN_3 113.45 6.1 18.581 5.382E-002 6.981 6.780 0.000 0.000 0.000 0.000 13.761 No
5 PERIMETER_ZN_4 67.30 3.6 18.581 5.382E-002 6.981 6.780 0.000 0.000 0.000 0.000 13.761 No
6 ATTIC 567.98 0.0 N/A 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 No


People Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Number of People {} People/Floor Area {person/m2} Floor Area per person {m2/person} Fraction Radiant Fraction Convected Sensible Fraction Calculation Activity level ASHRAE 55 Warnings Carbon Dioxide Generation Rate Nominal Minimum Number of People Nominal Maximum Number of People
1 CORE_ZN BLDG_OCC_SCH_WO_SB CORE_ZN 149.66 8.1 8.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 8
2 PERIMETER_ZN_1 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_1 113.45 6.1 6.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 6
3 PERIMETER_ZN_2 BLDG_OCC_SCH_W_SB PERIMETER_ZN_2 67.30 3.6 3.6 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 4
4 PERIMETER_ZN_3 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_3 113.45 6.1 6.1 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 6
5 PERIMETER_ZN_4 BLDG_OCC_SCH_WO_SB PERIMETER_ZN_4 67.30 3.6 3.6 5.382E-002 18.581 0.300 0.700 AutoCalculate ACTIVITY_SCH No 3.8200E-008 0 4


Lights Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Lighting Level {W} Lights/Floor Area {W/m2} Lights per person {W/person} Fraction Return Air Fraction Radiant Fraction Short Wave Fraction Convected Fraction Replaceable End-Use Category Nominal Minimum Lighting Level {W} Nominal Maximum Lighting Level {W}
1 CORE_ZN_LIGHTS LTG_SCH_OFFICE CORE_ZN 149.66 8.1 1044.832 6.981 129.720 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 1044.832
2 PERIMETER_ZN_1_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_1 113.45 6.1 792.050 6.981 129.720 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 792.050
3 PERIMETER_ZN_2_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_2 67.30 3.6 469.854 6.981 129.720 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 469.854
4 PERIMETER_ZN_3_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_3 113.45 6.1 792.050 6.981 129.720 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 792.050
5 PERIMETER_ZN_4_LIGHTS LTG_SCH_OFFICE PERIMETER_ZN_4 67.30 3.6 469.854 6.981 129.720 0.000 0.700 0.200 0.100 1.000 LightsWired 0.000 469.854


ElectricEquipment Internal Gains Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Equipment Level {W} Equipment/Floor Area {W/m2} Equipment per person {W/person} Fraction Latent Fraction Radiant Fraction Lost Fraction Convected End-Use SubCategory Nominal Minimum Equipment Level {W} Nominal Maximum Equipment Level {W}
1 CORE_ZN_MISCPLUG_EQUIP BLDG_EQUIP_SCH CORE_ZN 149.66 8.1 1014.677 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 1014.677
2 PERIMETER_ZN_1_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_1 113.45 6.1 769.191 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 769.191
3 PERIMETER_ZN_2_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_2 67.30 3.6 456.294 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 456.294
4 PERIMETER_ZN_3_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_3 113.45 6.1 769.191 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 769.191
5 PERIMETER_ZN_4_MISCPLUG_EQUIP BLDG_EQUIP_SCH PERIMETER_ZN_4 67.30 3.6 456.294 6.780 125.977 0.000 0.000 0.000 1.000 MiscPlug 0.000 456.294


Shadowing/Sun Position Calculations Annual Simulations

Shading Calculation Method Shading Calculation Update Frequency Method Shading Calculation Update Frequency {days} Maximum Figures in Shadow Overlap Calculations {} Polygon Clipping Algorithm Pixel Counting Resolution Sky Diffuse Modeling Algorithm Output External Shading Calculation Results Disable Self-Shading Within Shading Zone Groups Disable Self-Shading From Shading Zone Groups to Other Zones
1 PolygonClipping Periodic 30 15000 SutherlandHodgman 512 SimpleSkyDiffuseModeling No No No


Enclosure/Window Adjacency Daylighting Counts

Enclosure Name Number of Exterior Windows Number of Exterior Windows in Adjacent Enclosures
1 PERIMETER_ZN_1 7 0
2 PERIMETER_ZN_2 4 0
3 PERIMETER_ZN_3 6 0
4 PERIMETER_ZN_4 4 0


Enclosure/Window Adjacency Daylighting Matrix

Enclosure Name Number of Adjacent Enclosures with Windows Adjacent Enclosure Names - 1st 100 (max)
1 PERIMETER_ZN_1 0  
2 PERIMETER_ZN_2 0  
3 PERIMETER_ZN_3 0  
4 PERIMETER_ZN_4 0  


Water Heater Information

Type Name Volume {m3} Maximum Capacity {W} Standard Rated Recovery Efficiency Standard Rated Energy Factor
1 WaterHeater:Mixed SWHSYS1 WATER HEATER 0.1514 11722.8 0.981 0.4610


ZoneInfiltration Airflow Stats Nominal

Name Schedule Name Zone Name Zone Floor Area {m2} # Zone Occupants Design Volume Flow Rate {m3/s} Volume Flow Rate/Floor Area {m3/s-m2} Volume Flow Rate/Exterior Surface Area {m3/s-m2} ACH - Air Changes per Hour Equation A - Constant Term Coefficient {} Equation B - Temperature Term Coefficient {1/C} Equation C - Velocity Term Coefficient {s/m} Equation D - Velocity Squared Term Coefficient {s2/m2}
1 PERIMETER_ZN_1_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_1 113.45 6.1 4.810E-002 4.240E-004 5.696E-004 0.500 0.000 0.000 0.224 0.000
2 PERIMETER_ZN_1_DOOR_INFILTRATION INFIL_DOOR_OPENING_SCH PERIMETER_ZN_1 113.45 6.1 7.646E-002 6.739E-004 9.053E-004 0.795 1.000 0.000 0.000 0.000
3 PERIMETER_ZN_2_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_2 67.30 3.6 3.207E-002 4.765E-004 5.696E-004 0.562 0.000 0.000 0.224 0.000
4 PERIMETER_ZN_3_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_3 113.45 6.1 4.810E-002 4.240E-004 5.444E-004 0.500 0.000 0.000 0.224 0.000
5 PERIMETER_ZN_4_INFILTRATION INFIL_QUARTER_ON_SCH PERIMETER_ZN_4 67.30 3.6 3.207E-002 4.765E-004 5.696E-004 0.562 0.000 0.000 0.224 0.000
6 ATTIC_INFILTRATION ALWAYS_ON ATTIC 567.98 0.0 0.200 3.523E-004 3.052E-004 1.000 1.000 0.000 0.000 0.000


AirFlow Model

Simple
1 Simple


RoomAir Model

Zone Name Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
1 CORE_ZN Mixing/Well-Stirred
2 PERIMETER_ZN_1 Mixing/Well-Stirred
3 PERIMETER_ZN_2 Mixing/Well-Stirred
4 PERIMETER_ZN_3 Mixing/Well-Stirred
5 PERIMETER_ZN_4 Mixing/Well-Stirred
6 ATTIC Mixing/Well-Stirred


AirflowNetwork Model:Control

No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
1 NoMultizoneOrDistribution


Zone Volume Capacitance Multiplier

Sensible Heat Capacity Multiplier Moisture Capacity Multiplier Carbon Dioxide Capacity Multiplier Generic Contaminant Capacity Multiplier
1 1.000 1.000 1.000 1.000


Load Timesteps in Zone Design Calculation Averaging Window

Value
1 6


Heating Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone CORE_ZN 1.2000
3 Zone PERIMETER_ZN_1 1.2000
4 Zone PERIMETER_ZN_2 1.2000
5 Zone PERIMETER_ZN_3 1.2000
6 Zone PERIMETER_ZN_4 1.2000


Cooling Sizing Factor Information

Sizing Factor ID Value
1 Global 1.2000
2 Zone CORE_ZN 1.2000
3 Zone PERIMETER_ZN_1 1.2000
4 Zone PERIMETER_ZN_2 1.2000
5 Zone PERIMETER_ZN_3 1.2000
6 Zone PERIMETER_ZN_4 1.2000


Sky Daylight Factors

Sky Type MonthAndDay Daylighting Control Name Enclosure Name Window Name Reference Point Daylight Factor
1 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 2.1544E-003
2 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 2.3883E-003
3 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 2.4326E-003
4 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 2.6513E-003
5 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 1.2669E-003
6 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 1.4338E-003
7 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT1 6.1598E-004
8 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 PERIMETER_ZN_1_DAYLREFPT2 6.8813E-004
9 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 1.2043E-002
10 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 1.2498E-002
11 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 1.2375E-002
12 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 1.3819E-002
13 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 1.0630E-002
14 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 7.4397E-003
15 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT1 5.2539E-003
16 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 PERIMETER_ZN_1_DAYLREFPT2 2.8471E-003
17 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 1.0563E-002
18 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 1.2003E-002
19 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 1.0917E-002
20 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 1.3342E-002
21 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 9.0156E-003
22 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 6.9514E-003
23 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT1 4.3618E-003
24 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 PERIMETER_ZN_1_DAYLREFPT2 2.6304E-003
25 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 2.1469E-003
26 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 2.3733E-003
27 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 2.4269E-003
28 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 2.6409E-003
29 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 1.2603E-003
30 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 1.4175E-003
31 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT1 6.1098E-004
32 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 PERIMETER_ZN_1_DAYLREFPT2 6.7699E-004
33 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 2.0645E-003
34 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 2.0882E-003
35 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 2.3536E-003
36 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 2.3749E-003
37 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 1.1950E-003
38 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 1.2113E-003
39 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT1 5.7661E-004
40 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 PERIMETER_ZN_1_DAYLREFPT2 5.8416E-004
41 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 2.0584E-003
42 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 2.0630E-003
43 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 2.3484E-003
44 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 2.3524E-003
45 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 1.1908E-003
46 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 1.1938E-003
47 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT1 5.7438E-004
48 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 PERIMETER_ZN_1_DAYLREFPT2 5.7584E-004
49 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 3.2082E-003
50 Clear Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 3.8679E-003
51 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 3.5556E-003
52 Clear Turbid Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 4.2310E-003
53 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 1.9748E-003
54 Intermediate Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 2.3528E-003
55 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT1 9.7553E-004
56 Overcast Sky 12/21 PERIMETER_ZN_1_DAYLCTRL PERIMETER_ZN_1 PERIMETER_ZN_1_WALL_SOUTH_DOOR PERIMETER_ZN_1_DAYLREFPT2 1.0957E-003
57 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 1.4433E-003
58 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.6185E-003
59 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 1.3406E-003
60 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.4707E-003
61 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 1.2026E-003
62 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.2623E-003
63 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT1 9.6654E-004
64 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_4 PERIMETER_ZN_2_DAYLREFPT2 1.0329E-003
65 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 5.9739E-003
66 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 4.5871E-003
67 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 4.8109E-003
68 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 3.8150E-003
69 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 4.1654E-003
70 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 3.3173E-003
71 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT1 4.7223E-003
72 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_3 PERIMETER_ZN_2_DAYLREFPT2 3.0223E-003
73 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 1.5222E-002
74 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 7.2282E-003
75 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 1.6181E-002
76 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 6.9940E-003
77 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 1.1972E-002
78 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 6.1044E-003
79 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT1 5.6333E-003
80 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_2 PERIMETER_ZN_2_DAYLREFPT2 3.2458E-003
81 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 1.8294E-003
82 Clear Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 2.2905E-003
83 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 1.8470E-003
84 Clear Turbid Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 2.3424E-003
85 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 1.3263E-003
86 Intermediate Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.5548E-003
87 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT1 9.7137E-004
88 Overcast Sky 12/21 PERIMETER_ZN_2_DAYLCTRL PERIMETER_ZN_2 PERIMETER_ZN_2_WALL_EAST_WINDOW_1 PERIMETER_ZN_2_DAYLREFPT2 1.0440E-003
89 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 7.5241E-004
90 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 8.9481E-004
91 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 6.0402E-004
92 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 7.1578E-004
93 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 4.9314E-004
94 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 5.6768E-004
95 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT1 6.0971E-004
96 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 PERIMETER_ZN_3_DAYLREFPT2 6.7280E-004
97 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 4.6808E-003
98 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 4.0308E-003
99 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 3.6917E-003
100 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 3.0768E-003
101 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 3.5335E-003
102 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 2.0962E-003
103 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT1 3.9804E-003
104 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 PERIMETER_ZN_3_DAYLREFPT2 2.5282E-003
105 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 6.5361E-003
106 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 4.7713E-003
107 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 5.0883E-003
108 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 3.6064E-003
109 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 4.7090E-003
110 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 2.3283E-003
111 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT1 5.7698E-003
112 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 PERIMETER_ZN_3_DAYLREFPT2 2.9613E-003
113 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 7.7070E-004
114 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 9.4256E-004
115 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 6.1834E-004
116 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 7.5169E-004
117 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 5.0417E-004
118 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 5.8796E-004
119 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT1 6.1975E-004
120 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 PERIMETER_ZN_3_DAYLREFPT2 6.9511E-004
121 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 6.8861E-004
122 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 7.0970E-004
123 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 5.5163E-004
124 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 5.6851E-004
125 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 4.4848E-004
126 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 4.5999E-004
127 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT1 5.7786E-004
128 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 PERIMETER_ZN_3_DAYLREFPT2 5.8626E-004
129 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 6.8254E-004
130 Clear Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 6.8675E-004
131 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 5.4664E-004
132 Clear Turbid Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 5.5005E-004
133 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 4.4465E-004
134 Intermediate Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 4.4702E-004
135 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT1 5.7533E-004
136 Overcast Sky 12/21 PERIMETER_ZN_3_DAYLCTRL PERIMETER_ZN_3 PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 PERIMETER_ZN_3_DAYLREFPT2 5.7691E-004
137 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 1.7465E-003
138 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 2.1500E-003
139 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 1.7358E-003
140 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 2.1578E-003
141 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 1.2943E-003
142 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 1.5116E-003
143 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT1 9.7294E-004
144 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_4 PERIMETER_ZN_4_DAYLREFPT2 1.0451E-003
145 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 1.3769E-002
146 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 6.6740E-003
147 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 1.4330E-002
148 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 6.3445E-003
149 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 1.1461E-002
150 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 5.7982E-003
151 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT1 5.6109E-003
152 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_3 PERIMETER_ZN_4_DAYLREFPT2 3.2041E-003
153 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 6.0034E-003
154 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 4.5387E-003
155 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 4.7908E-003
156 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 3.7348E-003
157 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 4.0670E-003
158 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 3.1872E-003
159 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT1 4.7187E-003
160 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_2 PERIMETER_ZN_4_DAYLREFPT2 2.9874E-003
161 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 1.3984E-003
162 Clear Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.5755E-003
163 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 1.2798E-003
164 Clear Turbid Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.4108E-003
165 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 1.1704E-003
166 Intermediate Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.2282E-003
167 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT1 9.6795E-004
168 Overcast Sky 12/21 PERIMETER_ZN_4_DAYLCTRL PERIMETER_ZN_4 PERIMETER_ZN_4_WALL_WEST_WINDOW_1 PERIMETER_ZN_4_DAYLREFPT2 1.0340E-003


Zone Sizing Information

Zone Name Load Type Calc Des Load {W} User Des Load {W} Calc Des Air Flow Rate {m3/s} User Des Air Flow Rate {m3/s} Design Day Name Date/Time of Peak Temperature at Peak {C} Humidity Ratio at Peak {kgWater/kgDryAir} Floor Area {m2} # Occupants Calc Outdoor Air Flow Rate {m3/s} Calc DOAS Heat Addition Rate {W}
1 CORE_ZN Cooling 3132.27966 3758.73559 0.23315 0.27978 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 16:00:00 28.77600 8.82049E-003 149.65740 8.05449 6.46221E-002 0.00000
2 CORE_ZN Heating 777.65725 933.18870 3.40120E-002 6.46221E-002 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -4.20000 2.69032E-003 149.65740 8.05449 6.46221E-002 0.00000
3 PERIMETER_ZN_1 Cooling 4531.58252 5437.89902 0.33732 0.40478 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 29.40000 8.82150E-003 113.45000 6.10582 4.89877E-002 0.00000
4 PERIMETER_ZN_1 Heating 2524.00244 3028.80293 0.11038 0.13246 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -4.20000 2.69032E-003 113.45000 6.10582 4.89877E-002 0.00000
5 PERIMETER_ZN_2 Cooling 2634.62491 3161.54989 0.19610 0.23532 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 25.44800 8.81519E-003 67.30000 3.62205 2.90601E-002 0.00000
6 PERIMETER_ZN_2 Heating 1597.77493 1917.32991 6.98766E-002 8.38520E-002 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -4.20000 2.69032E-003 67.30000 3.62205 2.90601E-002 0.00000
7 PERIMETER_ZN_3 Cooling 2662.29202 3194.75043 0.19817 0.23780 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:50:00 28.88000 8.82066E-003 113.45000 6.10582 4.89877E-002 0.00000
8 PERIMETER_ZN_3 Heating 2509.56574 3011.47889 0.10975 0.13170 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -4.20000 2.69032E-003 113.45000 6.10582 4.89877E-002 0.00000
9 PERIMETER_ZN_4 Cooling 3158.02059 3789.62471 0.23506 0.28207 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 26.90400 8.81750E-003 67.30000 3.62205 2.90601E-002 0.00000
10 PERIMETER_ZN_4 Heating 1591.25791 1909.50949 6.95916E-002 8.35100E-002 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 -4.20000 2.69032E-003 67.30000 3.62205 2.90601E-002 0.00000


System Sizing Information

System Name Load Type Peak Load Kind User Design Capacity Calc Des Air Flow Rate [m3/s] User Des Air Flow Rate [m3/s] Design Day Name Date/Time of Peak
1 PSZ-AC:1 Cooling Sensible 4077.27 0.27978 0.27978 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 05:00:00
2 PSZ-AC:1 Heating Sensible 3406.87 6.46221E-002 6.46221E-002 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00
3 PSZ-AC:2 Cooling Sensible 5675.83 0.40478 0.40478 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 05:00:00
4 PSZ-AC:2 Heating Sensible 4463.50 0.13246 0.13246 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00
5 PSZ-AC:3 Cooling Sensible 3166.68 0.23532 0.23532 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 05:00:00
6 PSZ-AC:3 Heating Sensible 2766.65 8.38520E-002 8.38520E-002 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00
7 PSZ-AC:4 Cooling Sensible 3436.96 0.23780 0.23780 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 05:00:00
8 PSZ-AC:4 Heating Sensible 4446.43 0.13170 0.13170 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00
9 PSZ-AC:5 Cooling Sensible 3835.51 0.28207 0.28207 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 05:00:00
10 PSZ-AC:5 Heating Sensible 2758.94 8.35100E-002 8.35100E-002 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00


Component Sizing Information

Component Type Component Name Input Field Description Value
1 AirTerminal:SingleDuct:ConstantVolume:NoReheat CORE_ZN DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.27978
2 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_1 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.40478
3 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_2 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.23532
4 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_3 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.23780
5 AirTerminal:SingleDuct:ConstantVolume:NoReheat PERIMETER_ZN_4 DIRECT AIR Design Size Maximum Air Flow Rate [m3/s] 0.28207
6 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.27978
7 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.27978
8 AirLoopHVAC PSZ-AC:1 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.27978
9 AirLoopHVAC PSZ-AC:1 Adjusted Heating Design Air Flow Rate [m3/s] 0.27978
10 AirLoopHVAC PSZ-AC:1 Adjusted Cooling Design Air Flow Rate [m3/s] 0.27978
11 AirLoopHVAC PSZ-AC:1 Adjusted Main Design Air Flow Rate [m3/s] 0.27978
12 AirLoopHVAC PSZ-AC:1 User Heating Air Flow Ratio [] 1.00000
13 AirLoopHVAC PSZ-AC:1 Calculated Heating Air Flow Ratio [] 1.00000
14 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.40478
15 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.40478
16 AirLoopHVAC PSZ-AC:2 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.40478
17 AirLoopHVAC PSZ-AC:2 Adjusted Heating Design Air Flow Rate [m3/s] 0.40478
18 AirLoopHVAC PSZ-AC:2 Adjusted Cooling Design Air Flow Rate [m3/s] 0.40478
19 AirLoopHVAC PSZ-AC:2 Adjusted Main Design Air Flow Rate [m3/s] 0.40478
20 AirLoopHVAC PSZ-AC:2 User Heating Air Flow Ratio [] 1.00000
21 AirLoopHVAC PSZ-AC:2 Calculated Heating Air Flow Ratio [] 1.00000
22 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.23532
23 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.23532
24 AirLoopHVAC PSZ-AC:3 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.23532
25 AirLoopHVAC PSZ-AC:3 Adjusted Heating Design Air Flow Rate [m3/s] 0.23532
26 AirLoopHVAC PSZ-AC:3 Adjusted Cooling Design Air Flow Rate [m3/s] 0.23532
27 AirLoopHVAC PSZ-AC:3 Adjusted Main Design Air Flow Rate [m3/s] 0.23532
28 AirLoopHVAC PSZ-AC:3 User Heating Air Flow Ratio [] 1.00000
29 AirLoopHVAC PSZ-AC:3 Calculated Heating Air Flow Ratio [] 1.00000
30 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.23780
31 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.23780
32 AirLoopHVAC PSZ-AC:4 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.23780
33 AirLoopHVAC PSZ-AC:4 Adjusted Heating Design Air Flow Rate [m3/s] 0.23780
34 AirLoopHVAC PSZ-AC:4 Adjusted Cooling Design Air Flow Rate [m3/s] 0.23780
35 AirLoopHVAC PSZ-AC:4 Adjusted Main Design Air Flow Rate [m3/s] 0.23780
36 AirLoopHVAC PSZ-AC:4 User Heating Air Flow Ratio [] 1.00000
37 AirLoopHVAC PSZ-AC:4 Calculated Heating Air Flow Ratio [] 1.00000
38 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Maximum Heating Flow Rates [m3/s] 0.28207
39 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Minimum Heating Flow Rates [m3/s] 0.28207
40 AirLoopHVAC PSZ-AC:5 Sum of Air Terminal Maximum Flow Rates [m3/s] 0.28207
41 AirLoopHVAC PSZ-AC:5 Adjusted Heating Design Air Flow Rate [m3/s] 0.28207
42 AirLoopHVAC PSZ-AC:5 Adjusted Cooling Design Air Flow Rate [m3/s] 0.28207
43 AirLoopHVAC PSZ-AC:5 Adjusted Main Design Air Flow Rate [m3/s] 0.28207
44 AirLoopHVAC PSZ-AC:5 User Heating Air Flow Ratio [] 1.00000
45 AirLoopHVAC PSZ-AC:5 Calculated Heating Air Flow Ratio [] 1.00000
46 AirLoopHVAC PSZ-AC:1 Design Supply Air Flow Rate [m3/s] 0.27978
47 AirLoopHVAC PSZ-AC:2 Design Supply Air Flow Rate [m3/s] 0.40478
48 AirLoopHVAC PSZ-AC:3 Design Supply Air Flow Rate [m3/s] 0.23532
49 AirLoopHVAC PSZ-AC:4 Design Supply Air Flow Rate [m3/s] 0.23780
50 AirLoopHVAC PSZ-AC:5 Design Supply Air Flow Rate [m3/s] 0.28207
51 Controller:OutdoorAir PSZ-AC:1_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.27978
52 Controller:OutdoorAir PSZ-AC:1_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 6.46221E-002
53 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.27978
54 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4784.84076
55 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80086
56 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.27978
57 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.27978
58 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.27978
59 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.27978
60 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 4784.84076
61 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 4784.84076
62 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
63 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 3406.86872
64 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:1_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
65 Fan:OnOff PSZ-AC:1 FAN Design Size Maximum Flow Rate [m3/s] 0.27978
66 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.27978
67 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4784.84076
68 Coil:Heating:Fuel PSZ-AC:1_SUPPHEATCOIL Design Size Nominal Capacity [W] 3406.86872
69 Controller:OutdoorAir PSZ-AC:2_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.40478
70 Controller:OutdoorAir PSZ-AC:2_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 4.89877E-002
71 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.40478
72 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 6700.57250
73 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
74 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.40478
75 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.40478
76 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.40478
77 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.40478
78 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 6700.57250
79 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 6700.57250
80 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
81 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4463.49855
82 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:2_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
83 Fan:OnOff PSZ-AC:2 FAN Design Size Maximum Flow Rate [m3/s] 0.40478
84 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.40478
85 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL Design Size Gross Rated Heating Capacity [W] 6700.57250
86 Coil:Heating:Fuel PSZ-AC:2_SUPPHEATCOIL Design Size Nominal Capacity [W] 4463.49855
87 Controller:OutdoorAir PSZ-AC:3_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.23532
88 Controller:OutdoorAir PSZ-AC:3_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.90601E-002
89 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.23532
90 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 3895.41576
91 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
92 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.23532
93 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.23532
94 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.23532
95 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.23532
96 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 3895.41576
97 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 3895.41576
98 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
99 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 2766.64970
100 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:3_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
101 Fan:OnOff PSZ-AC:3 FAN Design Size Maximum Flow Rate [m3/s] 0.23532
102 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.23532
103 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL Design Size Gross Rated Heating Capacity [W] 3895.41576
104 Coil:Heating:Fuel PSZ-AC:3_SUPPHEATCOIL Design Size Nominal Capacity [W] 2766.64970
105 Controller:OutdoorAir PSZ-AC:4_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.23780
106 Controller:OutdoorAir PSZ-AC:4_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 4.89877E-002
107 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.23780
108 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4014.39827
109 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80051
110 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.23780
111 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.23780
112 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.23780
113 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.23780
114 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 4014.39827
115 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 4014.39827
116 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
117 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 4446.42687
118 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:4_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
119 Fan:OnOff PSZ-AC:4 FAN Design Size Maximum Flow Rate [m3/s] 0.23780
120 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.23780
121 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4014.39827
122 Coil:Heating:Fuel PSZ-AC:4_SUPPHEATCOIL Design Size Nominal Capacity [W] 4446.42687
123 Controller:OutdoorAir PSZ-AC:5_OA_CONTROLLER Maximum Outdoor Air Flow Rate [m3/s] 0.28207
124 Controller:OutdoorAir PSZ-AC:5_OA_CONTROLLER Minimum Outdoor Air Flow Rate [m3/s] 2.90601E-002
125 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Rated Air Flow Rate [m3/s] 0.28207
126 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Gross Rated Total Cooling Capacity [W] 4669.29472
127 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL Design Size Gross Rated Sensible Heat Ratio 0.80066
128 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate [m3/s] 0.28207
129 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate During Heating Operation [m3/s] 0.28207
130 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate During Cooling Operation [m3/s] 0.28207
131 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supply Air Flow Rate When No Cooling or Heating is Needed [m3/s] 0.28207
132 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Nominal Heating Capacity [W] 4669.29472
133 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Nominal Cooling Capacity [W] 4669.29472
134 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Maximum Supply Air Temperature from Supplemental Heater [C] 40.00000
135 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Supplemental Heating Coil Nominal Capacity [W] 2758.94319
136 AirLoopHVAC:UnitaryHeatPump:AirToAir PSZ-AC:5_UNITARY_PACKAGE_DX Fraction of Supply Air Flow That Goes Through the Controlling Zone 1.00000
137 Fan:OnOff PSZ-AC:5 FAN Design Size Maximum Flow Rate [m3/s] 0.28207
138 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL Design Size Rated Air Flow Rate [m3/s] 0.28207
139 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL Design Size Gross Rated Heating Capacity [W] 4669.29472
140 Coil:Heating:Fuel PSZ-AC:5_SUPPHEATCOIL Design Size Nominal Capacity [W] 2758.94319
141 PlantLoop SWHSYS1 Maximum Loop Flow Rate [m3/s] 4.04800E-006
142 PlantLoop SWHSYS1 Plant Loop Volume [m3] 4.85760E-004
143 Pump:ConstantSpeed SWHSYS1 PUMP Design Flow Rate [m3/s] 4.04800E-006
144 Pump:ConstantSpeed SWHSYS1 PUMP Design Power Consumption [W] 1.72991E-008


DX Cooling Coil Standard Rating Information

Component Type Component Name Standard Rating (Net) Cooling Capacity {W} Standard Rated Net COP {W/W} EER {Btu/W-h} SEER User {Btu/W-h} SEER Standard {Btu/W-h} IEER {Btu/W-h}
1 Coil:Cooling:DX:SingleSpeed PSZ-AC:1 HP COOLING COIL 4565.5 3.31 11.30 11.82 11.18 11.07
2 Coil:Cooling:DX:SingleSpeed PSZ-AC:2 HP COOLING COIL 6383.3 3.29 11.22 11.74 11.10 10.96
3 Coil:Cooling:DX:SingleSpeed PSZ-AC:3 HP COOLING COIL 3711.0 3.29 11.22 11.74 11.10 10.96
4 Coil:Cooling:DX:SingleSpeed PSZ-AC:4 HP COOLING COIL 3828.0 3.30 11.27 11.79 11.15 11.03
5 Coil:Cooling:DX:SingleSpeed PSZ-AC:5 HP COOLING COIL 4448.2 3.29 11.22 11.74 11.10 10.96


DX Heating Coil Standard Rating Information

Component Type Component Name High Temperature Heating (net) Rating Capacity {W} Low Temperature Heating (net) Rating Capacity {W} HSPF {Btu/W-h} Region Number
1 Coil:Heating:DX:SingleSpeed PSZ-AC:1 HEATING COIL 5007.0 2785.4 7.36 4
2 Coil:Heating:DX:SingleSpeed PSZ-AC:2 HEATING COIL 7021.7 3910.7 7.32 4
3 Coil:Heating:DX:SingleSpeed PSZ-AC:3 HEATING COIL 4082.1 2273.5 7.32 4
4 Coil:Heating:DX:SingleSpeed PSZ-AC:4 HEATING COIL 4203.2 2339.3 7.33 4
5 Coil:Heating:DX:SingleSpeed PSZ-AC:5 HEATING COIL 4893.1 2725.2 7.35 4


Environment

Environment Name Environment Type Start Date End Date Start DayOfWeek Duration {#days} Source:Start DayOfWeek Use Daylight Saving Use Holidays Apply Weekend Holiday Rule Use Rain Values Use Snow Values Sky Temperature Model
1 RUNPERIOD 1 WeatherFileRunPeriod 01/01/2017 12/31/2017 Sunday 365 Use RunPeriod Specified Day No No No Yes Yes Clark and Allen


Environment:Special Days

Special Day Name Special Day Type Source Start Date Duration {#days}
1 NEW YEARS DAY Holiday InputFile 01/01 1Environment:Special Days


Environment:Daylight Saving

Daylight Saving Indicator Source Start Date End Date
1 Yes InputFile 03/12 11/05


Tabular Report

Style Unit Conversion
1 Commaandhtml commaandhtml


Warmup Convergence Information

Zone Name Environment Type/Name Average Warmup Temperature Difference {deltaC} Std Dev Warmup Temperature Difference {deltaC} Max Temperature Pass/Fail Convergence Min Temperature Pass/Fail Convergence Average Warmup Load Difference {W} Std Dev Warmup Load Difference {W} Heating Load Pass/Fail Convergence Cooling Load Pass/Fail Convergence
1 CORE_ZN RunPeriod: RUNPERIOD 1 1.8409289185E-003 1.5529914990E-003 Pass Pass 0.0000000000 0.0000000000 Pass Pass
2 PERIMETER_ZN_1 RunPeriod: RUNPERIOD 1 0.2180464155 0.1992372755 Pass Pass 0.8864316164 2.0151469080 Pass Pass
3 PERIMETER_ZN_2 RunPeriod: RUNPERIOD 1 0.2333612490 0.2150311109 Pass Pass 0.6059708960 1.5140535568 Pass Pass
4 PERIMETER_ZN_3 RunPeriod: RUNPERIOD 1 0.2237508386 0.2032488116 Pass Pass 0.8371550800 1.8832684731 Pass Pass
5 PERIMETER_ZN_4 RunPeriod: RUNPERIOD 1 0.2349338256 0.2163011699 Pass Pass 0.6063660329 1.5169377633 Pass Pass
6 ATTIC RunPeriod: RUNPERIOD 1 0.1127088653 0.1143171039 Pass Pass 0.0000000000 0.0000000000 Pass Pass



Table of Contents

Report: Annual Heat Emissions Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Heat Emission by Components

Envelope Convection Zone Exfiltration Zone Exhaust Air HVAC Relief Air HVAC Reject Heat Total
Heat Emissions [GJ] 776.17 33.93 0.00 37.78 29.47 877.35



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB -4.20 0.00 -4.20 Wetbulb [C] 4.30 20.00
SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 29.40 10.40 18.30 Wetbulb [C] 4.20 350.00


Monthly Precipitation Summary

Monthly Total Precipitation from .epw [mm] Monthly Total Hours of Rain from .epw Monthly Total Precipitation in Site:Precipitation [mm] Monthly Total Roof Irrigation Depth [mm] Monthly Total Rain Collection Volume [m3]
Jan 0.00 0      
Feb 0.00 0      
Mar 22.00 23      
Apr 0.00 0      
May 0.00 0      
Jun 16.00 20      
Jul 0.00 0      
Aug 24.00 18      
Sep 12.00 15      
Oct 61.00 41      
Nov 0.00 0      
Dec 45.00 41      


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_ZN_1_WALL_SOUTH NONRES_EXT_WALL_GRD 0.30 0.547 0.596 84.45 63.82 180.00 90.00 S
PERIMETER_ZN_1_FLOOR PERIMETER_ZN_1_FLOOR_FFACTOR 1.00 0.219 0.227 113.45 113.45 135.00 180.00  
PERIMETER_ZN_2_WALL_EAST NONRES_EXT_WALL_GRD 0.30 0.547 0.596 56.30 45.15 90.00 90.00 E
PERIMETER_ZN_2_FLOOR PERIMETER_ZN_2_FLOOR_FFACTOR 1.00 0.246 0.257 67.30 67.30 270.00 180.00  
PERIMETER_ZN_3_WALL_NORTH NONRES_EXT_WALL_GRD 0.30 0.547 0.596 84.45 63.83 0.00 90.00 N
PERIMETER_ZN_3_FLOOR PERIMETER_ZN_3_FLOOR_FFACTOR 1.00 0.219 0.227 113.45 113.45 180.00 180.00  
PERIMETER_ZN_4_WALL_WEST NONRES_EXT_WALL_GRD 0.30 0.547 0.596 56.30 45.15 270.00 90.00 W
PERIMETER_ZN_4_FLOOR PERIMETER_ZN_4_FLOOR_FFACTOR 1.00 0.246 0.257 67.30 67.30 90.00 180.00  
ATTIC_SOFFIT_WEST EXT_SOFFIT_FLOOR 0.30 3.082 7.547 11.44 11.44 270.00 180.00  
ATTIC_SOFFIT_SOUTH EXT_SOFFIT_FLOOR 0.30 3.082 7.547 16.97 16.97 225.00 180.00  
ATTIC_SOFFIT_EAST EXT_SOFFIT_FLOOR 0.30 3.082 7.547 11.44 11.44 45.00 180.00  
ATTIC_SOFFIT_NORTH EXT_SOFFIT_FLOOR 0.30 3.082 7.547 16.97 16.97 315.00 180.00  
ATTIC_ROOF_NORTH ATTICROOFDECK 0.30 2.858 4.706 197.51 197.51 0.00 18.45  
ATTIC_ROOF_WEST ATTICROOFDECK 0.30 2.858 4.706 101.87 101.87 270.00 18.45  
ATTIC_ROOF_EAST ATTICROOFDECK 0.30 2.858 4.706 101.87 101.87 90.00 18.45  
ATTIC_ROOF_SOUTH ATTICROOFDECK 0.30 2.858 4.706 197.51 197.51 180.00 18.45  


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
CORE_ZN_WALL_SOUTH INT_WALL 0.30 2.511 6.299 53.95 53.95 180.00 90.00 S
CORE_ZN_WALL_EAST INT_WALL 0.30 2.511 6.299 25.80 25.80 90.00 90.00 E
CORE_ZN_WALL_NORTH INT_WALL 0.30 2.511 6.299 53.95 53.95 0.00 90.00 N
CORE_ZN_WALL_WEST INT_WALL 0.30 2.511 6.299 25.80 25.80 270.00 90.00 W
CORE_ZN_FLOOR CORE_ZN_FLOOR_FFACTOR 1.00 0.006 0.006 149.66 149.66 270.00 180.00  
CORE_ZN_CEILING NONRES_ROOF 0.30 0.118 0.122 149.66 149.66 270.00 0.00  
PERIMETER_ZN_1_WALL_WEST INT_WALL 0.30 2.511 6.299 21.57 21.57 315.00 90.00 N
PERIMETER_ZN_1_WALL_EAST INT_WALL 0.30 2.511 6.299 21.57 21.57 45.00 90.00 E
PERIMETER_ZN_1_WALL_NORTH INT_WALL 0.30 2.511 6.299 53.95 53.95 0.00 90.00 N
PERIMETER_ZN_1_CEILING NONRES_ROOF 0.30 0.118 0.122 113.45 113.45 45.00 0.00  
PERIMETER_ZN_2_WALL_NORTH INT_WALL 0.30 2.511 6.299 21.57 21.57 315.00 90.00 N
PERIMETER_ZN_2_WALL_SOUTH INT_WALL 0.30 2.511 6.299 21.57 21.57 225.00 90.00 W
PERIMETER_ZN_2_WALL_WEST INT_WALL 0.30 2.511 6.299 25.80 25.80 270.00 90.00 W
PERIMETER_ZN_2_CEILING NONRES_ROOF 0.30 0.118 0.122 67.30 67.30 270.00 0.00  
PERIMETER_ZN_3_WALL_SOUTH INT_WALL 0.30 2.511 6.299 53.95 53.95 180.00 90.00 S
PERIMETER_ZN_3_WALL_WEST INT_WALL 0.30 2.511 6.299 21.57 21.57 225.00 90.00 W
PERIMETER_ZN_3_WALL_EAST INT_WALL 0.30 2.511 6.299 21.57 21.57 135.00 90.00 S
PERIMETER_ZN_3_CEILING NONRES_ROOF 0.30 0.118 0.122 113.45 113.45 180.00 0.00  
PERIMETER_ZN_4_WALL_SOUTH INT_WALL 0.30 2.511 6.299 21.57 21.57 135.00 90.00 S
PERIMETER_ZN_4_WALL_NORTH INT_WALL 0.30 2.511 6.299 21.57 21.57 45.00 90.00 E
PERIMETER_ZN_4_WALL_EAST INT_WALL 0.30 2.511 6.299 25.80 25.80 90.00 90.00 E
PERIMETER_ZN_4_CEILING NONRES_ROOF 0.30 0.118 0.122 67.30 67.30 90.00 0.00  
ATTIC_FLOOR_PERIMETER_SOUTH NONRES_ROOF_FLOOR 0.30 0.118 0.122 113.45 113.45 180.00 180.00  
ATTIC_FLOOR_PERIMETER_WEST NONRES_ROOF_FLOOR 0.30 0.118 0.122 67.30 67.30 315.00 180.00  
ATTIC_FLOOR_PERIMETER_EAST NONRES_ROOF_FLOOR 0.30 0.118 0.122 67.30 67.30 135.00 180.00  
ATTIC_FLOOR_CORE NONRES_ROOF_FLOOR 0.30 0.118 0.122 149.66 149.66 270.00 180.00  
ATTIC_FLOOR_PERIMETER_NORTH NONRES_ROOF_FLOOR 0.30 0.118 0.122 113.45 113.45 315.00 180.00  
CORE_ZN_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 299.31   0.00 90.00 N
PERIMETER_ZN_1_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 226.90   0.00 90.00 N
PERIMETER_ZN_2_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.60   0.00 90.00 N
PERIMETER_ZN_3_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 226.90   0.00 90.00 N
PERIMETER_ZN_4_INTERNALMASS_1 INTERIORFURNISHINGS 0.30   0.800 134.60   0.00 90.00 N


Exterior Fenestration

Construction Frame and Divider Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 WINDOW_U_0.363_SHGC_SOUTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 WINDOW_U_0.363_SHGC_SOUTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 WINDOW_U_0.363_SHGC_SOUTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 WINDOW_U_0.363_SHGC_SOUTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 WINDOW_U_0.363_SHGC_SOUTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 WINDOW_U_0.363_SHGC_SOUTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_1_WALL_SOUTH_DOOR WINDOW_U_0.363_SHGC_SOUTH_0.359   3.91 0.00 0.00 3.91 3.91 2.062 0.360 0.396             No PERIMETER_ZN_1_WALL_SOUTH 180.00 90.00 S
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 WINDOW_U_0.363_SHGC_EAST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 WINDOW_U_0.363_SHGC_EAST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 WINDOW_U_0.363_SHGC_EAST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 WINDOW_U_0.363_SHGC_EAST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_2_WALL_EAST 90.00 90.00 E
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 WINDOW_U_0.363_SHGC_NORTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 WINDOW_U_0.363_SHGC_NORTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 WINDOW_U_0.363_SHGC_NORTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 WINDOW_U_0.363_SHGC_NORTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 WINDOW_U_0.363_SHGC_NORTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 WINDOW_U_0.363_SHGC_NORTH_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_3_WALL_NORTH 0.00 90.00 N
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 WINDOW_U_0.363_SHGC_WEST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 WINDOW_U_0.363_SHGC_WEST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 WINDOW_U_0.363_SHGC_WEST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 WINDOW_U_0.363_SHGC_WEST_0.359   2.79 0.00 0.00 2.79 2.79 2.062 0.360 0.396             No PERIMETER_ZN_4_WALL_WEST 270.00 90.00 W
Total or Average             59.65 2.062 0.360 0.396                      
North Total or Average             16.72 2.062 0.360 0.396                      
Non-North Total or Average             42.93 2.062 0.360 0.396                      


Exterior Fenestration Shaded State

Frame and Divider Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance NFRC Product Type Assembly U-Factor [W/m2-K] Assembly SHGC Assembly Visible Transmittance
None                


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance
Total or Average     0.00 - - -


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
PERIMETER_ZN_3_WALL_NORTH_DOOR1 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_ZN_3_WALL_NORTH
PERIMETER_ZN_3_WALL_NORTH_DOOR2 SWINGING DOOR_CON 1.598 2.101 1.95 PERIMETER_ZN_3_WALL_NORTH


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Shading Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Sunlit Fraction

March 21 9am March 21 noon March 21 3pm June 21 9am June 21 noon June 21 3pm December 21 9am December 21 noon December 21 3pm
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1 1.00 1.00 1.00 0.00 0.54 0.28 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2 1.00 1.00 1.00 0.00 0.54 0.28 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3 1.00 1.00 1.00 0.00 0.54 0.28 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4 1.00 1.00 1.00 0.00 0.54 0.28 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5 1.00 1.00 1.00 0.00 0.54 0.28 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6 1.00 1.00 1.00 0.02 0.54 0.28 1.00 1.00 1.00
PERIMETER_ZN_1_WALL_SOUTH_DOOR 1.00 1.00 1.00 0.18 0.81 0.62 1.00 1.00 1.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_4 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_3 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_2 1.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 0.00
PERIMETER_ZN_2_WALL_EAST_WINDOW_1 1.00 0.04 0.00 1.00 0.00 0.00 1.00 0.73 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_3 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_4 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3_WALL_NORTH_WINDOW_6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_4 0.00 0.00 1.00 0.00 0.00 0.86 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_3 0.00 0.00 1.00 0.00 0.00 0.86 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_2 0.00 0.00 1.00 0.00 0.00 0.86 0.00 0.00 1.00
PERIMETER_ZN_4_WALL_WEST_WINDOW_1 0.00 0.00 1.00 0.00 0.00 0.86 0.00 0.00 1.00


Window Control

Name Type Shaded Construction Control Glare Control
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Interior Lighting

Zone Name Space Name Space Type Lighting Power Density [W/m2] Space Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [GJ]
CORE_ZN_LIGHTS CORE_ZN CORE_ZN GENERAL 6.9815 149.66 1044.83 LightsWired LTG_SCH_OFFICE 55.32 168.00 44.56 0.0000 Y 8.74
PERIMETER_ZN_1_LIGHTS PERIMETER_ZN_1 PERIMETER_ZN_1 GENERAL 6.9815 113.45 792.05 LightsWired LTG_SCH_OFFICE 55.32 168.00 36.84 0.0000 Y 5.48
PERIMETER_ZN_2_LIGHTS PERIMETER_ZN_2 PERIMETER_ZN_2 GENERAL 6.9815 67.30 469.85 LightsWired LTG_SCH_OFFICE 55.32 168.00 37.91 0.0000 Y 3.34
PERIMETER_ZN_3_LIGHTS PERIMETER_ZN_3 PERIMETER_ZN_3 GENERAL 6.9815 113.45 792.05 LightsWired LTG_SCH_OFFICE 55.32 168.00 39.10 0.0000 Y 5.81
PERIMETER_ZN_4_LIGHTS PERIMETER_ZN_4 PERIMETER_ZN_4 GENERAL 6.9815 67.30 469.85 LightsWired LTG_SCH_OFFICE 55.32 168.00 37.98 0.0000 Y 3.35
Interior Lighting Total       6.9815 511.16 3568.64               26.72


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
PERIMETER_ZN_1_DAYLREFPT1 PERIMETER_ZN_1 PERIMETER_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.24 792.05 190.01
PERIMETER_ZN_1_DAYLREFPT2 PERIMETER_ZN_1 PERIMETER_ZN_1_DAYLCTRL SplitFlux Continuous/Off 0.03 792.05 23.92
PERIMETER_ZN_2_DAYLREFPT1 PERIMETER_ZN_2 PERIMETER_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.24 469.85 112.72
PERIMETER_ZN_2_DAYLREFPT2 PERIMETER_ZN_2 PERIMETER_ZN_2_DAYLCTRL SplitFlux Continuous/Off 0.03 469.85 14.19
PERIMETER_ZN_3_DAYLREFPT1 PERIMETER_ZN_3 PERIMETER_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.24 792.05 190.01
PERIMETER_ZN_3_DAYLREFPT2 PERIMETER_ZN_3 PERIMETER_ZN_3_DAYLCTRL SplitFlux Continuous/Off 0.03 792.05 23.92
PERIMETER_ZN_4_DAYLREFPT1 PERIMETER_ZN_4 PERIMETER_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.24 469.85 112.72
PERIMETER_ZN_4_DAYLREFPT2 PERIMETER_ZN_4 PERIMETER_ZN_4_DAYLCTRL SplitFlux Continuous/Off 0.03 469.85 14.19


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [GJ]
EXTERIOR_LIGHTS_A 87.95 AstronomicalClock -   42.59 42.59 0.70
EXTERIOR_LIGHTS_B 200.47 AstronomicalClock -   83.55 63.07 2.37
EXTERIOR_LIGHTS_C 773.25 AstronomicalClock -   83.55 47.80 6.94
Exterior Lighting Total 1061.67           10.01



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Central Plant

Type Reference Capacity [W] Reference Efficiency [W/W] Rated Capacity [W] Rated Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None              


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4784.84 3831.99 952.85 0.80 4.12    
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   6700.57 5364.85 1335.72 0.80 4.12    
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   3895.42 3118.89 776.53 0.80 4.12    
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4014.40 3213.58 800.82 0.80 4.12    
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed   4669.29 3738.50 930.80 0.80 4.12    
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
PSZ-AC:1 HP COOLING COIL   4565.5 3.31 11.30 11.82 11.18 11.07
PSZ-AC:2 HP COOLING COIL   6383.3 3.29 11.22 11.74 11.10 10.96
PSZ-AC:3 HP COOLING COIL   3711.0 3.29 11.22 11.74 11.10 10.96
PSZ-AC:4 HP COOLING COIL   3828.0 3.30 11.27 11.79 11.15 11.03
PSZ-AC:5 HP COOLING COIL   4448.2 3.29 11.22 11.74 11.10 10.96
ANSI/AHRI ratings account for supply air fan heat and electric power. SEER User is calculated using user-input PLF curve and cooling coefficient of degradation whereas SEER Standard is calculated using AHRI Std 210/240-2008 default PLF curve and cooling coefficient of degradation.

DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed                


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed 5007.0 2785.4 7.36 4
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed 7021.7 3910.7 7.32 4
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed 4082.1 2273.5 7.32 4
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed 4203.2 2339.3 7.33 4
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed 4893.1 2725.2 7.35 4
ANSI/AHRI ratings account for supply air fan heat and electric power.

Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed   4784.84 3.36
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel   3406.87 0.80
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed   6700.57 3.36
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel   4463.50 0.80
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed   3895.42 3.36
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel   2766.65 0.80
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed   4014.40 3.36
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel   4446.43 0.80
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed   4669.29 3.36
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel   2758.94 0.80
Nominal values are gross at rated conditions, i.e., the supply air fan heat and electric power NOT accounted for.

Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
PSZ-AC:1 FAN Fan:OnOff 0.56 622.50 0.28 313.38 1120.11 1.00 1.95 General SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00
PSZ-AC:2 FAN Fan:OnOff 0.56 622.50 0.40 453.40 1120.11 1.00 1.71 General SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:3 FAN Fan:OnOff 0.56 622.50 0.24 263.59 1120.11 1.00 2.09 General SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00
PSZ-AC:4 FAN Fan:OnOff 0.56 622.50 0.24 266.36 1120.11 1.00 2.08 General SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:50:00
PSZ-AC:5 FAN Fan:OnOff 0.56 622.50 0.28 315.95 1120.11 1.00 1.94 General SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
SWHSYS1 PUMP Pump:ConstantSpeed Intermittent 0.00 0.000004 0.00 0.00 0.30 General


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
SWHSYS1 WATER HEATER WaterHeater:Mixed 0.15 11722.84 1.00 0.98 0.46



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
CORE_ZN 3132.28 3758.74 25.12 0.233 0.280 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 16:00:00 23.89 23.89 0.00907 28.78 0.00882 0.065 0.00
PERIMETER_ZN_1 4531.58 5437.90 47.93 0.337 0.405 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 23.89 23.89 0.00880 29.40 0.00882 0.049 0.00
PERIMETER_ZN_2 2634.62 3161.55 46.98 0.196 0.235 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 23.89 23.89 0.00881 25.45 0.00882 0.029 0.00
PERIMETER_ZN_3 2662.29 3194.75 28.16 0.198 0.238 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:50:00 23.89 23.89 0.00900 28.88 0.00882 0.049 0.00
PERIMETER_ZN_4 3158.02 3789.62 56.31 0.235 0.282 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 23.89 23.89 0.00876 26.90 0.00882 0.029 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
CORE_ZN 777.66 933.19 6.24 0.034 0.065 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00800 -4.20 0.00269 0.065 0.00
PERIMETER_ZN_1 2524.00 3028.80 26.70 0.110 0.132 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00747 -4.20 0.00269 0.049 0.00
PERIMETER_ZN_2 1597.77 1917.33 28.49 0.070 0.084 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00745 -4.20 0.00269 0.029 0.00
PERIMETER_ZN_3 2509.57 3011.48 26.54 0.110 0.132 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00747 -4.20 0.00269 0.049 0.00
PERIMETER_ZN_4 1591.26 1909.51 28.37 0.070 0.084 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 21.11 21.11 0.00745 -4.20 0.00269 0.029 0.00
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
PSZ-AC:1 0.28 0.28 0.06 0.06 0.2798 0.2798 0.2798 1.0000 1.0000
PSZ-AC:2 0.40 0.40 0.13 0.13 0.4048 0.4048 0.4048 1.0000 1.0000
PSZ-AC:3 0.24 0.24 0.08 0.08 0.2353 0.2353 0.2353 1.0000 1.0000
PSZ-AC:4 0.24 0.24 0.13 0.13 0.2378 0.2378 0.2378 1.0000 1.0000
PSZ-AC:5 0.28 0.28 0.08 0.08 0.2821 0.2821 0.2821 1.0000 1.0000


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:1 4784.841 3831.991 0.279779 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 16:00:00 4748.20 4363.57 0.279779 25.94 17.35 0.00901385 12.80 11.97 0.00850000 28.78 0.00882049 18.14 23.0975 23.89 0.00907544 48.4344 3119.01 0.00 4784.02 3799.66
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:1 4784.841 4784.841 0.279779 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 4784.84 4784.84 0.279779 15.26 11.25 0.00677360 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 23.0975 21.11 0.00800000 50.6363 776.87 0.00 4791.13 4791.13
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:1 3406.869 3406.869 -999.0 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 3406.87 3406.87 0.279779 15.26 11.25 0.00677360 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 23.0975 21.11 0.00800000 50.6363 776.87 0.00 -999.00 -999.00
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:2 6700.573 5364.849 0.404782 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 6573.73 6239.53 0.404782 25.48 17.01 0.00880245 12.80 11.97 0.00850000 29.40 0.00882150 18.34 12.1023 23.89 0.00879982 46.9848 4531.58 0.00 6699.42 5318.93
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:2 6700.573 6700.573 0.404782 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 6700.57 6700.57 0.404782 18.05 12.52 0.00689557 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 12.1023 21.11 0.00747458 47.3532 2524.00 0.00 6709.38 6709.38
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:2 4463.499 4463.499 -999.0 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4463.50 4463.50 0.404782 18.05 12.52 0.00689557 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 12.1023 21.11 0.00747458 47.3532 2524.00 0.00 -999.00 -999.00
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:3 3895.416 3118.885 0.235322 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 3888.59 3680.89 0.235322 25.01 16.85 0.00880803 12.80 11.97 0.00850000 25.45 0.00881519 17.01 12.3491 23.89 0.00880702 47.0207 2634.62 0.00 3894.75 3092.19
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:3 3895.416 3895.416 0.235322 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 3895.42 3895.42 0.235322 17.98 12.46 0.00686183 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 12.3491 21.11 0.00744955 47.1968 1597.77 0.00 3900.53 3900.53
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:3 2766.650 2766.650 -999.0 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 2766.65 2766.65 0.235322 17.98 12.46 0.00686183 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 12.3491 21.11 0.00744955 47.1968 1597.77 0.00 -999.00 -999.00
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:4 4014.398 3213.583 0.237800 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:20:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:50:00 3974.43 3679.56 0.237800 25.84 17.27 0.00896399 12.80 11.97 0.00850000 28.88 0.00882066 18.17 20.6004 23.89 0.00900319 48.0542 2653.50 0.00 4013.71 3186.51
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:4 4014.398 4014.398 0.237800 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4014.40 4014.40 0.237800 15.90 11.22 0.00648684 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 20.6004 21.11 0.00747185 47.3362 2509.57 0.00 4019.67 4019.67
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:4 4446.427 4446.427 -999.0 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4446.43 4446.43 0.237800 15.90 11.22 0.00648684 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 20.6004 21.11 0.00747185 47.3362 2509.57 0.00 -999.00 -999.00
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoopHVAC PSZ-AC:5 4669.295 3738.495 0.282072 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 4630.05 4419.28 0.282072 25.12 16.86 0.00876257 12.80 11.97 0.00850000 26.90 0.00881750 17.51 10.3024 23.89 0.00875626 46.7537 3158.02 0.00 4668.49 3706.50
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoopHVAC PSZ-AC:5 4669.295 4669.295 0.282072 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 4669.29 4669.29 0.282072 18.50 12.76 0.00695743 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 10.3024 21.11 0.00744753 47.1842 1591.26 0.00 4675.43 4675.43
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel AirLoopHVAC PSZ-AC:5 2758.943 2758.943 -999.0 -999.0 -999.000 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 2758.94 2758.94 0.282072 18.50 12.76 0.00695743 40.00 21.01 0.00800000 -4.20 0.00269032 -4.20 10.3024 21.11 0.00744753 47.1842 1591.26 0.00 -999.00 -999.00



Table of Contents

Report: Coil Sizing Details

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Coils

Coil Type Coil Location HVAC Type HVAC Name Zone Name(s) System Sizing Method Concurrence System Sizing Method Capacity System Sizing Method Air Flow Autosized Coil Capacity? Autosized Coil Airflow? Autosized Coil Water Flow? OA Pretreated prior to coil inlet? Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Terminal Unit Reheat Coil Multiplier DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio Moist Air Heat Capacity [J/kg-K] Dry Air Heat Capacity [J/kg-K] Standard Air Density Adjusted for Elevation [kg/m3] Supply Fan Name for Coil Supply Fan Type for Coil Supply Fan Maximum Air Volume Flow Rate [m3/s] Supply Fan Maximum Air Mass Flow Rate [kg/s] Plant Name for Coil Plant Fluid Specific Heat Capacity [J/kg-K] Plant Fluid Density [kg/m3] Plant Maximum Fluid Mass Flow Rate [kg/s] Plant Design Fluid Return Temperature [C] Plant Design Fluid Supply Temperature [C] Plant Design Fluid Temperature Difference [deltaC] Plant Design Capacity [W] Coil Capacity Percentage of Plant Design Capacity [%] Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Total Ideal Loads Peak Date/Time at Total Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Peak Load Type to Size On Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] Supply Fan Air Heat Gain at Ideal Loads Peak [W] Coil and Fan Net Total Capacity at Ideal Loads Peak [W] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] Outdoor Air Flow Percentage at Ideal Loads Peak [%] System Return Air Drybulb at Ideal Loads Peak [C] System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W] Coil Air Mass Flow Rate at Rating Conditions [kg/s] Coil Entering Air Drybulb at Rating Conditions [C] Coil Entering Air Wetbulb at Rating Conditions [C] Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] Coil Leaving Air Drybulb at Rating Conditions [C] Coil Leaving Air Wetbulb at Rating Conditions [C] Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K]
PSZ-AC:1 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4784.841 3831.991 0.279779 -999.0 -999.000 -999.0000 1.00000 1.00000 1021.5963 1004.8586 1.1870 PSZ-AC:1 FAN Fan:OnOff 0.279779 0.33209552   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 16:00:00 Sensible 4748.20 4363.57 0.9923 0.33209552 0.279779 25.94 17.35 0.00901385 49045.1 12.80 11.97 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 313.383 4434.81 28.78 0.00882049 18.14 0.06462207 23.0975 23.89 0.00907192 23.89 0.00907544 48.4344 3119.01 0.00 4784.02 3799.66 0.31898025 26.67 19.44 0.01118466 55322.4 15.03 14.40 0.00997473 40324.5
PSZ-AC:1 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4784.841 4784.841 0.279779 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:1 FAN Fan:OnOff 0.279779 0.33209552   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 4784.84 4784.84 1.0000 0.33209552 0.279779 15.26 11.25 0.00677360 32470.5 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4784.84 -4.20 0.00269032 -4.20 0.06462207 23.0975 21.11 0.00800000 21.11 0.00800000 50.6363 776.87 0.00 4791.13 4791.13 0.32622729 21.11 15.56 0.00875166 43444.1 35.49 20.38 0.00875166 58130.6
PSZ-AC:1_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:1 CORE_ZN Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 3406.869 3406.869 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:1 FAN Fan:OnOff 0.279779 0.33209552   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 00:10:00 Sensible 3406.87 3406.87 1.0000 0.33209552 0.279779 15.26 11.25 0.00677360 32470.5 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 3406.87 -4.20 0.00269032 -4.20 0.06462207 23.0975 21.11 0.00800000 21.11 0.00800000 50.6363 776.87 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:2 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 6700.573 5364.849 0.404782 -999.0 -999.000 -999.0000 1.02549 1.00000 1021.2033 1004.8586 1.1870 PSZ-AC:2 FAN Fan:OnOff 0.404782 0.48047201   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 14:20:00 Sensible 6573.73 6239.53 0.9811 0.48047201 0.404782 25.48 17.01 0.00880245 48034.6 12.80 11.97 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 453.399 6120.33 29.40 0.00882150 18.34 0.04898771 12.1023 23.89 0.00879982 23.89 0.00879982 46.9848 4531.58 0.00 6699.42 5318.93 0.46149700 26.67 19.44 0.01118466 55322.4 15.41 14.58 0.01001183 40805.7
PSZ-AC:2 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 6700.573 6700.573 0.404782 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:2 FAN Fan:OnOff 0.404782 0.48047201   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 6700.57 6700.57 1.0000 0.48047201 0.404782 18.05 12.52 0.00689557 35610.1 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 6700.57 -4.20 0.00269032 -4.20 0.04898771 12.1023 21.11 0.00747458 21.11 0.00747458 47.3532 2524.00 0.00 6709.38 6709.38 0.47198192 21.11 15.56 0.00875166 43444.1 35.03 20.23 0.00875166 57659.4
PSZ-AC:2_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:2 PERIMETER_ZN_1 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4463.499 4463.499 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:2 FAN Fan:OnOff 0.404782 0.48047201   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4463.50 4463.50 1.0000 0.48047201 0.404782 18.05 12.52 0.00689557 35610.1 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4463.50 -4.20 0.00269032 -4.20 0.04898771 12.1023 21.11 0.00747458 21.11 0.00747458 47.3532 2524.00 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:3 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 3895.416 3118.885 0.235322 -999.0 -999.000 -999.0000 1.07879 1.00000 1021.2137 1004.8586 1.1870 PSZ-AC:3 FAN Fan:OnOff 0.235322 0.27932512   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 10:00:00 Sensible 3888.59 3680.89 0.9982 0.27932512 0.235322 25.01 16.85 0.00880803 47564.9 12.80 11.97 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 263.586 3625.00 25.45 0.00881519 17.01 0.02906014 12.3491 23.89 0.00880702 23.89 0.00880702 47.0207 2634.62 0.00 3894.75 3092.19 0.26829389 26.67 19.44 0.01118466 55322.4 15.41 14.58 0.01001183 40805.7
PSZ-AC:3 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 3895.416 3895.416 0.235322 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:3 FAN Fan:OnOff 0.235322 0.27932512   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 3895.42 3895.42 1.0000 0.27932512 0.235322 17.98 12.46 0.00686183 35460.9 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 3895.42 -4.20 0.00269032 -4.20 0.02906014 12.3491 21.11 0.00744955 21.11 0.00744955 47.1968 1597.77 0.00 3900.53 3900.53 0.27438936 21.11 15.56 0.00875166 43444.1 35.03 20.23 0.00875166 57659.4
PSZ-AC:3_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:3 PERIMETER_ZN_2 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 2766.650 2766.650 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:3 FAN Fan:OnOff 0.235322 0.27932512   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 2766.65 2766.65 1.0000 0.27932512 0.235322 17.98 12.46 0.00686183 35460.9 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 2766.65 -4.20 0.00269032 -4.20 0.02906014 12.3491 21.11 0.00744955 21.11 0.00744955 47.1968 1597.77 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:4 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4014.398 3213.583 0.237800 -999.0 -999.000 -999.0000 1.00000 1.00000 1021.5036 1004.8586 1.1870 PSZ-AC:4 FAN Fan:OnOff 0.237800 0.28226583   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:20:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:20:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 15:50:00 Sensible 3974.43 3679.56 0.9900 0.28226583 0.237800 25.84 17.27 0.00896399 48815.3 12.80 11.97 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 266.361 3708.07 28.88 0.00882066 18.17 0.04898771 20.6004 23.89 0.00900118 23.89 0.00900319 48.0542 2653.50 0.00 4013.71 3186.51 0.27111846 26.67 19.44 0.01118466 55322.4 15.18 14.47 0.00998841 40518.1
PSZ-AC:4 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4014.398 4014.398 0.237800 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:4 FAN Fan:OnOff 0.237800 0.28226583   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4014.40 4014.40 1.0000 0.28226583 0.237800 15.90 11.22 0.00648684 32387.0 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4014.40 -4.20 0.00269032 -4.20 0.04898771 20.6004 21.11 0.00747185 21.11 0.00747185 47.3362 2509.57 0.00 4019.67 4019.67 0.27727810 21.11 15.56 0.00875166 43444.1 35.31 20.32 0.00875166 57941.0
PSZ-AC:4_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:4 PERIMETER_ZN_3 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 4446.427 4446.427 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:4 FAN Fan:OnOff 0.237800 0.28226583   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4446.43 4446.43 1.0000 0.28226583 0.237800 15.90 11.22 0.00648684 32387.0 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4446.43 -4.20 0.00269032 -4.20 0.04898771 20.6004 21.11 0.00747185 21.11 0.00747185 47.3362 2509.57 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0
PSZ-AC:5 HP COOLING COIL Coil:Cooling:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident CoolingDesignCapacity N/A Yes Yes unknown No 4669.295 3738.495 0.282072 -999.0 -999.000 -999.0000 1.07153 1.00000 1021.1292 1004.8586 1.1870 PSZ-AC:5 FAN Fan:OnOff 0.282072 0.33481698   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 SEATTLE SEATTLE TACOMA INTL A ANN CLG .4% CONDNS DB=>MWB 8/21 18:00:00 Sensible 4630.05 4419.28 0.9916 0.33481698 0.282072 25.12 16.86 0.00876257 47569.8 12.80 11.97 0.00850000 34322.2 -999.0 -999.00 -999.00 -999.00 315.951 4314.09 26.90 0.00881750 17.51 0.02906014 10.3024 23.89 0.00875626 23.89 0.00875626 46.7537 3158.02 0.00 4668.49 3706.50 0.32159424 26.67 19.44 0.01118466 55322.4 15.41 14.58 0.01001183 40805.7
PSZ-AC:5 HEATING COIL Coil:Heating:DX:SingleSpeed AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident HeatingDesignCapacity N/A Yes Yes unknown No 4669.295 4669.295 0.282072 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:5 FAN Fan:OnOff 0.282072 0.33481698   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 4669.29 4669.29 1.0000 0.33481698 0.282072 18.50 12.76 0.00695743 36230.4 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 4669.29 -4.20 0.00269032 -4.20 0.02906014 10.3024 21.11 0.00744753 21.11 0.00744753 47.1842 1591.26 0.00 4675.43 4675.43 0.32890066 21.11 15.56 0.00875166 43444.1 35.03 20.23 0.00875166 57659.4
PSZ-AC:5_SUPPHEATCOIL Coil:Heating:Fuel AirLoop AirLoopHVAC PSZ-AC:5 PERIMETER_ZN_4 Non-Coincident HeatingDesignCapacity N/A Yes No unknown No 2758.943 2758.943 -999.0 -999.0 -999.000 -999.0000 1.00000 1.00000 1019.7116 1004.8586 1.1870 PSZ-AC:5 FAN Fan:OnOff 0.282072 0.33481698   -999.0000 -999.0000 -999.0 -999.00 -999.00 -999.00 -999.00 -999.0000 -999.0 SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 unknown unknown SEATTLE SEATTLE TACOMA INTL A ANN HTG 99.6% CONDNS DB 12/21 24:00:00 Sensible 2758.94 2758.94 1.0000 0.33481698 0.282072 18.50 12.76 0.00695743 36230.4 40.00 21.01 0.00800000 60796.0 -999.0 -999.00 -999.00 -999.00 0.000 2758.94 -4.20 0.00269032 -4.20 0.02906014 10.3024 21.11 0.00744753 21.11 0.00744753 47.1842 1591.26 0.00 -999.00 -999.00 -999.0 -999.00 -999.00 -999.0 -999.0 -999.00 -999.00 -999.0 -999.0



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
CORE_ZN 988.50 2563.67 170.17
PERIMETER_ZN_1 1530.83 3126.83 993.00
PERIMETER_ZN_2 1539.67 2674.00 1154.17
PERIMETER_ZN_3 1702.50 3511.00 1471.50
PERIMETER_ZN_4 1833.00 3215.83 1346.33
ATTIC 0.00 0.00 0.00
Facility 2419.50 3564.83 1541.00
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
CORE_ZN 3.00 2.50 3.00 2.50
PERIMETER_ZN_1 4.67 0.00 4.50 0.00
PERIMETER_ZN_2 9.33 0.00 6.83 0.00
PERIMETER_ZN_3 23.50 0.00 21.00 0.00
PERIMETER_ZN_4 7.33 0.00 4.83 0.00
ATTIC 0.00 0.00 0.00 0.00
Facility 26.33 2.50 21.00 2.50
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
CORE_ZN 4.75 8.05 456.46 0.367 0.000 0.000 0.000
PERIMETER_ZN_1 3.60 6.11 346.02 0.365 0.260 0.000 0.000
PERIMETER_ZN_2 1.93 3.62 205.26 0.333 0.063 0.000 0.000
PERIMETER_ZN_3 3.60 6.11 346.02 0.365 0.051 0.000 0.000
PERIMETER_ZN_4 2.13 3.62 205.26 0.365 0.057 0.000 0.000
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
CORE_ZN 4.75 8.05 456.46 0.000 0.000 0.000 0.000
PERIMETER_ZN_1 3.60 6.11 346.02 0.000 0.000 0.000 0.000
PERIMETER_ZN_2 1.93 3.62 205.26 0.000 0.000 0.000 0.000
PERIMETER_ZN_3 3.60 6.11 346.02 0.000 0.000 0.000 0.000
PERIMETER_ZN_4 2.13 3.62 205.26 0.000 0.000 0.000 0.000
Values shown for a single zone without multipliers


Table of Contents

Report: Outdoor Air Details

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Mechanical Ventilation Parameters by Zone

AirLoop Name Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Zone Area [m2] Design Zone Outdoor Airflow - Voz [m3/s] Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s]
CORE_ZN PSZ-AC:1 4.75 8.05 456.46 149.66 0.0646 0.065
PERIMETER_ZN_1 PSZ-AC:2 3.60 6.11 346.02 113.45 0.0490 0.049
PERIMETER_ZN_2 PSZ-AC:3 1.93 3.62 205.26 67.30 0.0291 0.029
PERIMETER_ZN_3 PSZ-AC:4 3.60 6.11 346.02 113.45 0.0490 0.049
PERIMETER_ZN_4 PSZ-AC:5 2.13 3.62 205.26 67.30 0.0291 0.029
Total Facility   16.00 27.51 1559.03 511.16 0.2207 0.221


Total Outdoor Air by Zone

Mechanical Ventilation [m3] Natural Ventilation [m3] Total Ventilation [m3] Infiltration [m3] Total Ventilation and Infiltration [m3] Dynamic Target Ventilation - Voz-dyn [m3] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr] Time Above Zero When Unoccupied [hr]
CORE_ZN 703501.65 0.00 703501.65 0.00 703501.65 2037921.45 5736.00 3024.00 0.00 0.00
PERIMETER_ZN_1 533299.81 0.00 533299.81 516414.74 1049714.55 1544876.42 5736.00 3024.00 0.00 0.00
PERIMETER_ZN_2 244679.86 0.00 244679.86 140974.35 385654.21 916440.58 6491.92 2268.08 0.00 382.41
PERIMETER_ZN_3 533299.81 0.00 533299.81 211461.52 744761.33 1544876.42 5736.00 3024.00 0.00 0.00
PERIMETER_ZN_4 316360.31 0.00 316360.31 140974.35 457334.66 916440.58 5736.00 3024.00 0.00 0.00
Total Facility 2331141.43 0.00 2331141.43 1009824.96 3340966.39 6960555.45 6491.92 3024.00 0.00 382.41


Average Outdoor Air During Occupancy by Zone - Flow Rates

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Infiltration [m3/s] Total Ventilation and Infiltration [m3/s] Dynamic Target Ventilation - Voz-dyn [m3/s] Time Below Voz-dyn [hr] Time At Voz-dyn [hr] Time Above Voz-dyn [hr]
CORE_ZN 0.0456 0.0000 0.0456 0.0000 0.0456 0.0646 1260.00 3024.00 0.00
PERIMETER_ZN_1 0.0346 0.0000 0.0346 0.0246 0.0592 0.0490 1260.00 3024.00 0.00
PERIMETER_ZN_2 0.0187 0.0000 0.0187 0.0035 0.0222 0.0291 1260.00 2268.00 0.00
PERIMETER_ZN_3 0.0346 0.0000 0.0346 0.0048 0.0394 0.0490 1260.00 3024.00 0.00
PERIMETER_ZN_4 0.0205 0.0000 0.0205 0.0032 0.0237 0.0291 1260.00 3024.00 0.00
Total Facility 0.1540 0.0000 0.1540 0.0361 0.1901 0.2207 2015.92 3024.00 0.00


Total Outdoor Air by AirLoop

Mechanical Ventilation [m3] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr] Time Above Zero When Unoccupied [hr]
PSZ-AC:1 991196.63 0.00 991196.63 2037921.45 5736.00 0.00 3024.00 0.00
PSZ-AC:2 751391.23 0.00 751391.23 1544876.42 5736.00 0.00 3024.00 0.00
PSZ-AC:3 344740.98 0.00 344740.98 916440.58 6490.26 0.06 2269.69 356.77
PSZ-AC:4 751391.23 0.00 751391.23 1544876.42 5736.00 0.00 3024.00 0.00
PSZ-AC:5 445734.94 0.00 445734.94 916440.58 5736.00 0.00 3024.00 0.00


Average Outdoor Air During Occupancy by AirLoop

Mechanical Ventilation [m3/s] Natural Ventilation [m3/s] Total Ventilation [m3/s] Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] Time Below Voz-sum-dyn [hr] Time At Voz-sum-dyn [hr] Time Above Voz-sum-dyn [hr]
PSZ-AC:1 0.0643 0.0000 0.0643 0.0646 1260.00 0.00 3024.00
PSZ-AC:2 0.0487 0.0000 0.0487 0.0490 1260.00 0.00 3024.00
PSZ-AC:3 0.0263 0.0000 0.0263 0.0291 1260.00 0.00 2268.00
PSZ-AC:4 0.0487 0.0000 0.0487 0.0490 1260.00 0.00 3024.00
PSZ-AC:5 0.0289 0.0000 0.0289 0.0291 1260.00 0.00 3024.00


Outdoor Air Controller Limiting Factors by AirLoop

No Limiting Factor [hr] Limits and Scheduled Limits [hr] Economizer [hr] Exhaust Flow [hr] Mixed Air Flow [hr] High Humidity [hr] Demand Controlled Ventilation [hr] Night Ventilation [hr] Demand Limiting [hr] Energy Management System [hr]
PSZ-AC:1 0.00 3024.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:2 0.00 3024.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:3 0.00 2624.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:4 0.00 3024.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
PSZ-AC:5 0.00 3024.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Average Outdoor Air for Limiting Factors During Occupancy

No Limiting Factor [m3/s] Limits and Scheduled Limits [m3/s] Economizer [m3/s] Exhaust Flow [m3/s] Mixed Air Flow [m3/s] High Humidity [m3/s] Demand Controlled Ventilation [m3/s] Night Ventilation [m3/s] Demand Limiting [m3/s] Energy Management System [m3/s]
PSZ-AC:1 0.0000 0.0910 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:2 0.0000 0.0690 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:3 0.0000 0.0409 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:4 0.0000 0.0690 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
PSZ-AC:5 0.0000 0.0409 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000



Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Surfaces by Class

Total Outdoors
Wall 20 4
Floor 14 8
Roof 9 4
Internal Mass 5 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 21 21
Door 2 2
Glass Door 1 1
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 5
Conditioned Zones 5
Unconditioned Zones 1
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 555
Defaulted Fields 365
Fields with Defaults 1333
Autosized Fields 115
Autosizable Fields 137
Autocalculated Fields 90
Autocalculatable Fields 156



Table of Contents

Report: Energy Meters

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Annual and Peak Values - Electricity

Electricity Annual Value [GJ] Electricity Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Electricity Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
Electricity:Facility 143.01 1248.68 01-JAN-08:20 17721.59 26-DEC-08:10
Electricity:Building 75.02 677.68 01-JAN-00:10 5866.25 02-JAN-16:30
Electricity:Zone:CORE_ZN 22.88 198.41 01-JAN-00:10 1717.53 02-JAN-08:10
Electricity:SpaceType:GENERAL 75.02 677.68 01-JAN-00:10 5866.25 02-JAN-16:30
InteriorLights:Electricity 26.72 110.04 01-JAN-00:10 2540.94 02-JAN-16:30
InteriorLights:Electricity:Zone:CORE_ZN 8.74 32.22 01-JAN-00:10 743.94 02-JAN-08:10
InteriorLights:Electricity:SpaceType:GENERAL 26.72 110.04 01-JAN-00:10 2540.94 02-JAN-16:30
LightsWired:InteriorLights:Electricity 26.72 110.04 01-JAN-00:10 2540.94 02-JAN-16:30
LightsWired:InteriorLights:Electricity:Zone:CORE_ZN 8.74 32.22 01-JAN-00:10 743.94 02-JAN-08:10
LightsWired:InteriorLights:Electricity:SpaceType:GENERAL 26.72 110.04 01-JAN-00:10 2540.94 02-JAN-16:30
Electricity:Zone:PERIMETER_ZN_1 16.20 150.41 01-JAN-00:10 1302.00 02-JAN-16:30
InteriorLights:Electricity:Zone:PERIMETER_ZN_1 5.48 24.42 01-JAN-00:10 563.96 02-JAN-16:30
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_1 5.48 24.42 01-JAN-00:10 563.96 02-JAN-16:30
Electricity:Zone:PERIMETER_ZN_2 9.70 89.23 01-JAN-00:10 772.36 02-JAN-16:30
InteriorLights:Electricity:Zone:PERIMETER_ZN_2 3.34 14.49 01-JAN-00:10 334.55 02-JAN-16:30
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_2 3.34 14.49 01-JAN-00:10 334.55 02-JAN-16:30
Electricity:Zone:PERIMETER_ZN_3 16.53 150.41 01-JAN-00:10 1302.00 02-JAN-16:30
InteriorLights:Electricity:Zone:PERIMETER_ZN_3 5.81 24.42 01-JAN-00:10 563.96 02-JAN-16:30
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_3 5.81 24.42 01-JAN-00:10 563.96 02-JAN-16:30
Electricity:Zone:PERIMETER_ZN_4 9.71 89.23 01-JAN-00:10 772.36 02-JAN-16:30
InteriorLights:Electricity:Zone:PERIMETER_ZN_4 3.35 14.49 01-JAN-00:10 334.55 02-JAN-16:30
LightsWired:InteriorLights:Electricity:Zone:PERIMETER_ZN_4 3.35 14.49 01-JAN-00:10 334.55 02-JAN-16:30
InteriorEquipment:Electricity 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
InteriorEquipment:Electricity:Zone:CORE_ZN 14.14 166.20 01-JAN-00:10 973.59 02-JAN-08:10
InteriorEquipment:Electricity:SpaceType:GENERAL 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:CORE_ZN 14.14 166.20 01-JAN-00:10 973.59 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:SpaceType:GENERAL 48.30 567.64 01-JAN-00:10 3325.31 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_1 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_1 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_2 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_2 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_3 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_3 10.72 125.99 01-JAN-00:10 738.04 02-JAN-08:10
InteriorEquipment:Electricity:Zone:PERIMETER_ZN_4 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
MiscPlug:InteriorEquipment:Electricity:Zone:PERIMETER_ZN_4 6.36 74.74 01-JAN-00:10 437.82 02-JAN-08:10
ElectricityPurchased:Facility 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
ElectricityPurchased:Plant 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
Cogeneration:ElectricityPurchased 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
General:Cogeneration:ElectricityPurchased 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
ElectricitySurplusSold:Facility 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricitySurplusSold:Plant 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cogeneration:ElectricitySurplusSold 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
ElectricityNet:Facility 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
ElectricityNet:Plant 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
Cogeneration:ElectricityNet 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
General:Cogeneration:ElectricityNet 143.01 1248.68 11-JUN-09:30 17721.59 26-DEC-08:10
ExteriorLights:Electricity 10.01 0.00 01-JAN-08:10 1061.67 01-JAN-06:10
General:ExteriorLights:Electricity 10.01 0.00 01-JAN-08:10 1061.67 01-JAN-06:10
Electricity:HVAC 33.17 0.00 01-JAN-00:10 9249.55 21-FEB-08:00
Fans:Electricity 18.43 0.00 01-JAN-00:10 1612.68 02-JAN-06:10
General:Fans:Electricity 18.43 0.00 01-JAN-00:10 1612.68 02-JAN-06:10
Cooling:Electricity 7.17 0.00 01-JAN-00:10 4488.12 10-AUG-16:00
General:Cooling:Electricity 7.17 0.00 01-JAN-00:10 4488.12 10-AUG-16:00
Heating:Electricity 7.57 0.00 01-JAN-00:10 7636.87 21-FEB-08:00
General:Heating:Electricity 7.57 0.00 01-JAN-00:10 7636.87 21-FEB-08:00
Electricity:Plant 24.80 571.00 01-JAN-00:10 2813.06 17-FEB-12:50
WaterSystems:Electricity 24.80 571.00 01-JAN-00:10 2813.06 17-FEB-12:50
Water Heater:WaterSystems:Electricity 24.80 571.00 01-JAN-00:10 2813.06 17-FEB-12:50
Pumps:Electricity 0.00 0.00 01-JAN-00:10 0.00 02-JAN-07:10
General:Pumps:Electricity 0.00 0.00 01-JAN-00:10 0.00 02-JAN-07:10


Annual and Peak Values - Natural Gas

Natural Gas Annual Value [GJ] Natural Gas Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Natural Gas Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
NaturalGas:Facility 0.74 0.00 01-JAN-00:10 19354.17 26-DEC-06:20
NaturalGas:HVAC 0.74 0.00 01-JAN-00:10 19354.17 26-DEC-06:20
Heating:NaturalGas 0.74 0.00 01-JAN-00:10 19354.17 26-DEC-06:20
General:Heating:NaturalGas 0.74 0.00 01-JAN-00:10 19354.17 26-DEC-06:20


Annual and Peak Values - Cooling

Cooling Annual Value [GJ] Cooling Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Cooling Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Water

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
Water:Facility 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water:Plant 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterSystems:Water 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:Water 29.16 0.00 01-JAN-00:10 0.00 10-MAR-12:40
MainsWater:Facility 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
MainsWater:Plant 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
WaterSystems:MainsWater 58.31 0.00 01-JAN-00:10 0.00 02-JAN-12:10
Water Heater:WaterSystems:MainsWater 29.16 0.00 01-JAN-00:10 0.00 10-MAR-12:40
WaterUse:WaterSystems:Water 29.16 0.00 01-JAN-00:10 0.00 13-FEB-12:10
WaterUse:WaterSystems:MainsWater 29.16 0.00 01-JAN-00:10 0.00 13-FEB-12:10


Annual and Peak Values - Other by Weight/Mass

Annual Value [kg] Minimum Value [kg/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [kg/s] Timestamp of Maximum {TIMESTAMP}
Carbon Equivalent:Facility 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10
CarbonEquivalentEmissions:Carbon Equivalent 0.00 0.000 01-JAN-00:10 0.000 01-JAN-00:10


Annual and Peak Values - Other Volumetric

Annual Value [m3] Minimum Value [m3/s] Timestamp of Minimum {TIMESTAMP} Maximum Value [m3/s] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other Liquid/Gas

Annual Value [L] Minimum Value [L] Timestamp of Minimum {TIMESTAMP} Maximum Value [L] Timestamp of Maximum {TIMESTAMP}
None          


Annual and Peak Values - Other

Annual Value [GJ] Minimum Value [W] Timestamp of Minimum {TIMESTAMP} Maximum Value [W] Timestamp of Maximum {TIMESTAMP}
EnergyTransfer:Facility 100.82 0.00 01-JAN-00:10 61630.53 17-JAN-06:20
EnergyTransfer:Building 49.29 0.00 01-JAN-00:10 31412.63 17-JAN-06:20
EnergyTransfer:Zone:CORE_ZN 14.20 0.00 01-JAN-00:10 6012.73 17-JAN-06:20
Heating:EnergyTransfer 14.56 0.00 01-JAN-00:10 31412.63 17-JAN-06:20
Heating:EnergyTransfer:Zone:CORE_ZN 0.76 0.00 01-JAN-00:10 6012.73 17-JAN-06:20
General:Heating:EnergyTransfer 14.56 0.00 01-JAN-00:10 31412.63 17-JAN-06:20
General:Heating:EnergyTransfer:Zone:CORE_ZN 0.76 0.00 01-JAN-00:10 6012.73 17-JAN-06:20
Cooling:EnergyTransfer 34.73 0.00 01-JAN-00:10 14612.86 14-AUG-15:20
Cooling:EnergyTransfer:Zone:CORE_ZN 13.44 0.00 01-JAN-00:10 3776.73 14-AUG-05:10
General:Cooling:EnergyTransfer 34.73 0.00 01-JAN-00:10 14612.86 14-AUG-15:20
General:Cooling:EnergyTransfer:Zone:CORE_ZN 13.44 0.00 01-JAN-00:10 3776.73 14-AUG-05:10
EnergyTransfer:Zone:PERIMETER_ZN_1 12.29 0.00 01-JAN-00:10 8618.31 17-JAN-06:20
Heating:EnergyTransfer:Zone:PERIMETER_ZN_1 4.30 0.00 01-JAN-00:10 8618.31 17-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_1 4.30 0.00 01-JAN-00:10 8618.31 17-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_1 7.98 0.00 01-JAN-00:10 5045.39 11-SEP-14:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_1 7.98 0.00 01-JAN-00:10 5045.39 11-SEP-14:00
EnergyTransfer:Zone:PERIMETER_ZN_2 6.56 0.00 01-JAN-00:10 5337.85 17-JAN-06:20
Heating:EnergyTransfer:Zone:PERIMETER_ZN_2 2.56 0.00 01-JAN-00:10 5337.85 17-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_2 2.56 0.00 01-JAN-00:10 5337.85 17-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_2 4.00 0.00 01-JAN-00:10 2878.18 14-AUG-10:10
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_2 4.00 0.00 01-JAN-00:10 2878.18 14-AUG-10:10
EnergyTransfer:Zone:PERIMETER_ZN_3 9.57 0.00 01-JAN-00:10 6152.67 21-FEB-06:10
Heating:EnergyTransfer:Zone:PERIMETER_ZN_3 4.35 0.00 01-JAN-00:10 6152.67 21-FEB-06:10
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_3 4.35 0.00 01-JAN-00:10 6152.67 21-FEB-06:10
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_3 5.22 0.00 01-JAN-00:10 2538.53 24-JUL-15:10
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_3 5.22 0.00 01-JAN-00:10 2538.53 24-JUL-15:10
EnergyTransfer:Zone:PERIMETER_ZN_4 6.68 0.00 01-JAN-00:10 5492.82 17-JAN-06:20
Heating:EnergyTransfer:Zone:PERIMETER_ZN_4 2.58 0.00 01-JAN-00:10 5492.82 17-JAN-06:20
General:Heating:EnergyTransfer:Zone:PERIMETER_ZN_4 2.58 0.00 01-JAN-00:10 5492.82 17-JAN-06:20
Cooling:EnergyTransfer:Zone:PERIMETER_ZN_4 4.09 0.00 01-JAN-00:10 2777.78 14-AUG-16:00
General:Cooling:EnergyTransfer:Zone:PERIMETER_ZN_4 4.09 0.00 01-JAN-00:10 2777.78 14-AUG-16:00
EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Heating:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Heating:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
Cooling:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
General:Cooling:EnergyTransfer:Zone:ATTIC 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
PlantLoopHeatingDemand:Facility 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10
PlantLoopHeatingDemand:Plant 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10
WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10
General:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10
EnergyTransfer:HVAC 51.52 0.00 01-JAN-00:10 30217.90 17-JAN-06:20
CoolingCoils:EnergyTransfer 32.75 0.00 01-JAN-00:10 18885.09 10-AUG-15:30
HeatingCoils:EnergyTransfer 18.77 0.00 01-JAN-00:10 30217.90 17-JAN-06:20
Water Heater:WaterSystems:PlantLoopHeatingDemand 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10
EnergyTransfer:Plant 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10
WaterSystems:EnergyTransfer 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10
WaterUse:WaterSystems:EnergyTransfer 0.00 0.00 01-JAN-00:10 100.06 02-JAN-07:10



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [GJ] HVAC Zone Eq & Other Sensible Air Cooling [GJ] HVAC Terminal Unit Sensible Air Heating [GJ] HVAC Terminal Unit Sensible Air Cooling [GJ] HVAC Input Heated Surface Heating [GJ] HVAC Input Cooled Surface Cooling [GJ] People Sensible Heat Addition [GJ] Lights Sensible Heat Addition [GJ] Equipment Sensible Heat Addition [GJ] Window Heat Addition [GJ] Interzone Air Transfer Heat Addition [GJ] Infiltration Heat Addition [GJ] Opaque Surface Conduction and Other Heat Addition [GJ] Equipment Sensible Heat Removal [GJ] Window Heat Removal [GJ] Interzone Air Transfer Heat Removal [GJ] Infiltration Heat Removal [GJ] Opaque Surface Conduction and Other Heat Removal [GJ]
CORE_ZN 0.000 0.000 0.763 -13.439 0.000 0.000 5.245 8.739 14.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -15.448
PERIMETER_ZN_1 0.000 0.000 4.304 -7.983 0.000 0.000 4.039 5.477 10.719 16.453 0.000 0.048 0.000 0.000 -8.606 0.000 -6.700 -17.752
PERIMETER_ZN_2 0.000 0.000 2.561 -3.996 0.000 0.000 1.770 3.344 6.359 6.422 0.000 0.003 0.000 0.000 -4.437 0.000 -1.796 -10.230
PERIMETER_ZN_3 0.000 0.000 4.352 -5.220 0.000 0.000 4.117 5.813 10.719 3.564 0.000 0.007 0.000 0.000 -6.784 0.000 -2.630 -13.939
PERIMETER_ZN_4 0.000 0.000 2.583 -4.092 0.000 0.000 2.413 3.350 6.359 6.962 0.000 0.003 0.000 0.000 -4.628 0.000 -1.830 -11.119
ATTIC 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9.275 21.888 0.000 0.000 0.000 -31.163 -0.001
Total Facility 0.000 0.000 14.563 -34.731 0.000 0.000 17.584 26.723 48.296 33.401 0.000 9.337 21.889 0.000 -24.456 0.000 -44.118 -68.488


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
CORE_ZN 12-JUN-05:03 0.00 0.00 0.00 -4207.36 0.00 0.00 56.50 32.22 486.79 0.00 0.00 0.00 3631.85 0.00 -0.00 0.00 0.00 0.00
PERIMETER_ZN_1 24-JUL-05:01 0.00 0.00 0.00 -6015.54 0.00 0.00 41.83 24.42 369.02 0.00 0.00 0.00 5975.12 0.00 -273.62 0.00 -121.23 0.00
PERIMETER_ZN_2 11-SEP-10:02 0.00 0.00 0.00 -3521.72 0.00 0.00 244.20 244.18 437.82 1526.82 0.00 0.00 1073.75 0.00 -0.00 0.00 -5.05 0.00
PERIMETER_ZN_3 24-JUL-05:01 0.00 0.00 0.00 -3677.16 0.00 0.00 43.23 24.42 369.02 328.51 0.00 0.00 2924.02 0.00 -0.00 0.00 -12.04 0.00
PERIMETER_ZN_4 24-JUL-05:01 0.00 0.00 0.00 -4195.19 0.00 0.00 23.11 14.49 218.91 0.00 0.00 0.00 4112.42 0.00 -164.90 0.00 -8.83 0.00
ATTIC - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 24-JUL-05:01 0.00 0.00 0.00 -21365.11 0.00 0.00 183.24 110.04 1662.65 1013.24 0.00 545.07 18440.05 0.00 -438.52 0.00 -150.66 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
CORE_ZN 21-FEB-06:01 0.00 0.00 7443.81 0.00 0.00 0.00 84.81 32.22 486.79 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 -8047.63
PERIMETER_ZN_1 23-JAN-06:01 0.00 0.00 10395.25 0.00 0.00 0.00 66.54 24.42 369.02 0.00 0.00 0.00 0.00 0.00 -449.86 0.00 -237.65 -10167.73
PERIMETER_ZN_2 23-JAN-06:01 0.00 0.00 6210.39 0.00 0.00 0.00 40.38 14.49 218.91 0.00 0.00 0.00 0.00 0.00 -228.79 0.00 -45.43 -6209.94
PERIMETER_ZN_3 13-FEB-06:01 0.00 0.00 6915.69 0.00 0.00 0.00 68.88 24.42 369.02 0.00 0.00 0.00 0.00 0.00 -412.91 0.00 -216.22 -6748.89
PERIMETER_ZN_4 27-MAR-05:01 0.00 0.00 6902.74 0.00 0.00 0.00 37.90 14.49 218.91 0.00 0.00 0.00 0.00 0.00 -265.26 0.00 -160.56 -6748.22
ATTIC - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Facility 23-JAN-06:01 0.00 0.00 37432.72 0.00 0.00 0.00 297.26 110.04 1662.65 0.00 0.00 442.51 0.00 0.00 -1242.15 0.00 -395.67 -38307.36



Table of Contents

Report: Standard 62.1 Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

System Ventilation Requirements for Cooling

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow - Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
PSZ-AC:1 0.2798 0.0000 8.0545 1.0000 Calculated from schedules 0.0646 0.2798 0.2310 1.0000 Not calculated 0.0646 0.2310    
PSZ-AC:2 0.4048 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.4048 0.1210 1.0000 Not calculated 0.0490 0.1210    
PSZ-AC:3 0.2353 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.2353 0.1235 1.0000 Not calculated 0.0291 0.1235    
PSZ-AC:4 0.2378 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.2378 0.2060 1.0000 Not calculated 0.0490 0.2060    
PSZ-AC:5 0.2821 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.2821 0.1030 1.0000 Not calculated 0.0291 0.1030    


System Ventilation Requirements for Heating

Sum of Zone Primary Air Flow - Vpz-sum [m3/s] System Population - Ps Sum of Zone Population - Pz-sum Occupant Diversity - D Origin of D Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] System Primary Airflow - Vps [m3/s] Average Outdoor Air Fraction - Xs System Ventilation Efficiency - Ev Calculation Method for Ev Outdoor Air Intake Flow Vot [m3/s] Percent Outdoor Air - %OA Environment Name of Peak System Population - Ps Date and Time of Last Peak System Population - Ps
PSZ-AC:1 0.2798 0.0000 8.0545 1.0000 Calculated from schedules 0.0646 0.2798 1.0000 1.0000 Not calculated 0.0646 0.2310    
PSZ-AC:2 0.4048 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.4048 1.0000 1.0000 Not calculated 0.0490 0.1210    
PSZ-AC:3 0.2353 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.2353 1.0000 1.0000 Not calculated 0.0291 0.1235    
PSZ-AC:4 0.2378 0.0000 6.1058 1.0000 Calculated from schedules 0.0490 0.2378 1.0000 1.0000 Not calculated 0.0490 0.2060    
PSZ-AC:5 0.2821 0.0000 3.6221 1.0000 Calculated from schedules 0.0291 0.2821 1.0000 1.0000 Not calculated 0.0291 0.1030    


Zone Ventilation Parameters

AirLoop Name People Outdoor Air Rate - Rp [m3/s-person] Zone Population - Pz Area Outdoor Air Rate - Ra [m3/s-m2] Zone Floor Area - Az [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Air Distribution Effectiveness - Ez-clg Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Air Distribution Effectiveness - Ez-htg Heating Zone Outdoor Airflow - Voz-htg [m3/s]
CORE_ZN PSZ-AC:1 0.000000 8.0545 0.000432 149.66 0.0646 1.0000 0.0646 1.000 0.0646
PERIMETER_ZN_1 PSZ-AC:2 0.000000 6.1058 0.000432 113.45 0.0490 1.0000 0.0490 1.000 0.0490
PERIMETER_ZN_2 PSZ-AC:3 0.000000 3.6221 0.000432 67.30 0.0291 1.0000 0.0291 1.000 0.0291
PERIMETER_ZN_3 PSZ-AC:4 0.000000 6.1058 0.000432 113.45 0.0490 1.0000 0.0490 1.000 0.0490
PERIMETER_ZN_4 PSZ-AC:5 0.000000 3.6221 0.000432 67.30 0.0291 1.0000 0.0291 1.000 0.0291


System Ventilation Parameters

People Outdoor Air Rate - Rp [m3/s-person] Sum of Zone Population - Pz-sum Area Outdoor Air Rate - Ra [m3/s-m2] Sum of Zone Floor Area - Az-sum [m2] Breathing Zone Outdoor Airflow - Vbz [m3/s] Cooling Zone Outdoor Airflow - Voz-clg [m3/s] Heating Zone Outdoor Airflow - Voz-htg [m3/s]
PSZ-AC:1 0.000000 8.05 0.000432 149.6574 0.0646 0.0646 0.0646
PSZ-AC:2 0.000000 6.11 0.000432 113.4500 0.0490 0.0490 0.0490
PSZ-AC:3 0.000000 3.62 0.000432 67.3000 0.0291 0.0291 0.0291
PSZ-AC:4 0.000000 6.11 0.000432 113.4500 0.0490 0.0490 0.0490
PSZ-AC:5 0.000000 3.62 0.000432 67.3000 0.0291 0.0291 0.0291


Zone Ventilation Calculations for Cooling Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
CORE_ZN PSZ-AC:1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2798 0.2798 0.2798 No 0.0646 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_1 PSZ-AC:2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4048 0.4048 0.4048 No 0.0490 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_2 PSZ-AC:3 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2353 0.2353 0.2353 No 0.0291 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_3 PSZ-AC:4 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2378 0.2378 0.2378 No 0.0490 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_4 PSZ-AC:5 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2821 0.2821 0.2821 No 0.0291 0.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Cooling Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Cooling - Voz-clg [m3/s] Zone Ventilation Efficiency - Evz-min
PSZ-AC:1 0.2798 0.2798 0.2798 0.2798 0.0646 1.0000
PSZ-AC:2 0.4048 0.4048 0.4048 0.4048 0.0490 1.0000
PSZ-AC:3 0.2353 0.2353 0.2353 0.2353 0.0291 1.0000
PSZ-AC:4 0.2378 0.2378 0.2378 0.2378 0.0490 1.0000
PSZ-AC:5 0.2821 0.2821 0.2821 0.2821 0.0291 1.0000


Zone Ventilation Calculations for Heating Design

AirLoop Name Box Type Zone Primary Airflow - Vpz [m3/s] Zone Discharge Airflow - Vdz [m3/s] Minimum Zone Primary Airflow - Vpz-min [m3/s] Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? Zone Outdoor Airflow Heating - Voz-htg [m3/s] Primary Outdoor Air Fraction - Zpz Primary Air Fraction - Ep Secondary Recirculation Fraction- Er Supply Air Fraction- Fa Mixed Air Fraction - Fb Outdoor Air Fraction - Fc Zone Ventilation Efficiency - Evz
CORE_ZN PSZ-AC:1 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2798 0.2798 0.2798 No 0.0646 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_1 PSZ-AC:2 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.4048 0.4048 0.4048 No 0.0490 0.3698 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_2 PSZ-AC:3 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2353 0.2353 0.2353 No 0.0291 0.3466 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_3 PSZ-AC:4 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2378 0.2378 0.2378 No 0.0490 0.3720 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000
PERIMETER_ZN_4 PSZ-AC:5 AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT 0.2821 0.2821 0.2821 No 0.0291 0.3480 1.0000 0.0000 0.0000 0.0000 0.0000 1.0000


System Ventilation Calculations for Heating Design

Sum of Zone Primary Airflow - Vpz-sum [m3/s] System Primary Airflow - Vps [m3/s] Sum of Zone Discharge Airflow - Vdz-sum [m3/s] Sum of Min Zone Primary Airflow - Vpz-min [m3/s] Zone Outdoor Airflow Heating - Voz-htg [m3/s] Zone Ventilation Efficiency - Evz-min
PSZ-AC:1 0.2798 0.2798 0.2798 0.2798 0.0646 1.0000
PSZ-AC:2 0.4048 0.4048 0.4048 0.4048 0.0490 1.0000
PSZ-AC:3 0.2353 0.2353 0.2353 0.2353 0.0291 1.0000
PSZ-AC:4 0.2378 0.2378 0.2378 0.2378 0.0490 1.0000
PSZ-AC:5 0.2821 0.2821 0.2821 0.2821 0.0291 1.0000



Table of Contents

Report: LEED Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Sec1.1A-General Information

Data
Weather File RUNPERIOD 1 ** Seattle Seattle Tacoma Intl A WA USA TMY3 WMO#=727930
Total gross floor area [m2] 511.16
Principal Heating Source Electricity


EAp2-1. Space Usage Type

Space Area [m2] Regularly Occupied Area [m2] Unconditioned Area [m2] Typical Hours/Week in Operation [hr/wk]
CORE_ZN 149.66 149.66 0.00 82.16
PERIMETER_ZN_1 113.45 113.45 0.00 82.16
PERIMETER_ZN_2 67.30 67.30 0.00 67.66
PERIMETER_ZN_3 113.45 113.45 0.00 82.16
PERIMETER_ZN_4 67.30 67.30 0.00 82.16
ATTIC 567.98 0.00 567.98 0.00
Totals 511.16 511.16 0.00  


EAp2-2. Advisory Messages

Data
Number of hours heating loads not met 21.00
Number of hours cooling loads not met 2.50
Number of hours not met 23.50


EAp2-3. Energy Type Summary

Utility Rate Virtual Rate [$/unit energy] Units of Energy Units of Demand
None        


EAp2-4/5. Performance Rating Method Compliance

Electricity Energy Use [GJ] Electricity Demand [W] Natural Gas Energy Use [GJ] Natural Gas Demand [W] Gasoline Use [GJ] Gasoline Demand [W] Diesel Use [GJ] Diesel Demand [W] Coal Use [GJ] Coal Demand [W] Fuel Oil No 1 Use [GJ] Fuel Oil No 1 Demand [W] Fuel Oil No 2 Use [GJ] Fuel Oil No 2 Demand [W] Propane Use [GJ] Propane Demand [W] Other Fuel 1 Use [GJ] Other Fuel 1 Demand [W] Other Fuel 2 Use [GJ] Other Fuel 2 Demand [W] District Cooling Use [GJ] District Cooling Demand [W] District Heating Use [GJ] District Heating Demand [W]
Heating -- General 7.57 7636.87 0.74 19354.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Cooling -- General 7.17 4488.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Lighting -- LightsWired 26.72 2540.94 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting -- General 10.01 1061.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment -- MiscPlug 48.30 3325.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans -- General 18.43 1612.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- Water Heater 24.80 2813.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems -- WaterUse 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Refrigeration -- Not Subdivided 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators -- General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


EAp2-6. Energy Use Summary

Process Subtotal [GJ] Total Energy Use [GJ]
Electricity 48.30 143.01
Natural Gas 0.00 0.74
Additional 0.00 0.00
Total 48.30 143.75


EAp2-7. Energy Cost Summary

Process Subtotal [$] Total Energy Cost [$]
Electricity 0.00  
Natural Gas 0.00  
Additional 0.00  
Total 0.00  
Process energy cost based on ratio of process to total energy.

L-1. Renewable Energy Source Summary

Rated Capacity [kW] Annual Energy Generated [GJ]
Photovoltaic 0.00 0.00
Wind 0.00 0.00


EAp2-17a. Energy Use Intensity - Electricity

Electricty [MJ/m2]
Interior Lighting (All) 52.28
Space Heating 14.81
Space Cooling 14.04
Fans (All) 36.05
Service Water Heating 48.52
Receptacle Equipment 94.48
Miscellaneous (All) 279.77
Subtotal 279.77


EAp2-17b. Energy Use Intensity - Natural Gas

Natural Gas [MJ/m2]
Space Heating 1.45
Service Water Heating 0.00
Miscellaneous (All) 1.45
Subtotal 1.45


EAp2-17c. Energy Use Intensity - Additional

Additional [MJ/m2]
Subtotal 0.00
Miscellaneous 0.00


EAp2-18. End Use Percentage

Percent [%]
Interior Lighting (All) 18.59
Space Heating 5.78
Space Cooling 4.99
Fans (All) 12.82
Service Water Heating 17.25
Receptacle Equipment 33.60
Miscellaneous 6.97


Schedules-Equivalent Full Load Hours (Schedule Type=Fraction)

Equivalent Full Load Hours of Operation Per Year [hr] Hours > 1% [hr]
LTG_SCH_OFFICE 2885. 8760.
BLDG_EQUIP_SCH 3948. 8760.
BLDG_OCC_SCH 2512. 4420.
BLDG_OCC_SCH_W_SB 1854. 3640.
BLDG_OCC_SCH_WO_SB 2533. 4420.
BINARY OCCUPANCY 4420. 4420.
INFIL_QUARTER_ON_SCH 5991. 8760.
INFIL_DOOR_OPENING_SCH 1121. 3380.
BLDG_SWH_SCH 2064. 3900.
ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_ALWAYS_ON 8760. 8760.
EXTERIOR_LGT_189_1 6200. 8760.
ALWAYS_OFF 0. 0.
HVACOPERATIONSCHD_W_SB 2600. 2600.
REHEATCOILAVAILSCHED 8760. 8760.
COOLINGCOILAVAILSCHED 8760. 8760.
MINOA_MOTORIZEDDAMPER_SCHED 3120. 3120.
MINOA_SCHED 8760. 8760.
WORK_EFF_SCH 0. 0.
CORE_ZN WATER EQUIPMENT LATENT FRACT SCHED 438. 8760.
CORE_ZN WATER EQUIPMENT SENSIBLE FRACT SCHED 1752. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A 6570. 6570.
EXTERIOR_LIGHTING_SCHEDULE_B 8103. 8760.
EXTERIOR_LIGHTING_SCHEDULE_A_IECC2015 3120. 3120.
EXTERIOR_LIGHTING_SCHEDULE_B_2016 7665. 8760.
EXTERIOR_LIGHTING_SCHEDULE_C_2016 6752. 8760.


Schedules-SetPoints (Schedule Type=Temperature)

First Object Used Month Assumed 11am First Wednesday [C] Days with Same 11am Value 11pm First Wednesday [C] Days with Same 11pm Value
HTGSETP_SCH_NO_OPTIMUM CORE_ZN DUAL SP CONTROL January 21.11 365 15.56 365
CLGSETP_SCH_NO_OPTIMUM CORE_ZN DUAL SP CONTROL July 23.89 365 29.44 365
HTGSETP_SCH_NO_OPTIMUM_W_SB PERIMETER_ZN_2 DUAL SP CONTROL January 20.55 365 15.56 365
CLGSETP_SCH_NO_OPTIMUM_W_SB PERIMETER_ZN_2 DUAL SP CONTROL July 23.89 365 29.44 365



Table of Contents

Report: Annual Thermal Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Heat Index Hours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
CORE_ZN 8745.00 15.00 0.00 0.00 0.00
PERIMETER_ZN_1 8680.50 79.50 0.00 0.00 0.00
PERIMETER_ZN_2 8713.17 46.83 0.00 0.00 0.00
PERIMETER_ZN_3 8760.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4 8603.17 156.83 0.00 0.00 0.00
ATTIC 7442.83 520.83 402.67 390.17 3.50
Min 7442.83 0.00 0.00 0.00 0.00
Max 8760.00 520.83 402.67 390.17 3.50
Average 8490.78 136.50 67.11 65.03 0.58
Sum 50944.67 819.00 402.67 390.17 3.50


Heat Index OccupantHours

Safe (≤ 26.7°C) [hr] Caution (> 26.7, ≤ 32.2°C) [hr] Extreme Caution (> 32.2, ≤ 39.4°C) [hr] Danger (> 39.4, ≤ 51.7°C) [hr] Extreme Danger (> 51.7°C) [hr]
CORE_ZN 17892.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_2 4788.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4 6804.00 0.00 0.00 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 17892.00 0.00 0.00 0.00 0.00
Average 9366.00 0.00 0.00 0.00 0.00
Sum 56196.00 0.00 0.00 0.00 0.00


Humidex Hours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
CORE_ZN 8042.33 717.67 0.00 0.00 0.00
PERIMETER_ZN_1 8664.33 95.67 0.00 0.00 0.00
PERIMETER_ZN_2 8711.00 49.00 0.00 0.00 0.00
PERIMETER_ZN_3 8758.83 1.17 0.00 0.00 0.00
PERIMETER_ZN_4 8601.00 159.00 0.00 0.00 0.00
ATTIC 7524.00 727.67 249.00 176.83 82.50
Min 7524.00 1.17 0.00 0.00 0.00
Max 8758.83 727.67 249.00 176.83 82.50
Average 8383.58 291.69 41.50 29.47 13.75
Sum 50301.50 1750.17 249.00 176.83 82.50


Humidex OccupantHours

Little to no Discomfort (≤ 29) [hr] Some Discomfort (> 29, ≤ 40) [hr] Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] Dangerous (> 45, ≤ 50) [hr] Heat Stroke Quite Possible (> 50) [hr]
CORE_ZN 17892.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_2 4788.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_3 13356.00 0.00 0.00 0.00 0.00
PERIMETER_ZN_4 6804.00 0.00 0.00 0.00 0.00
ATTIC 0.00 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00 0.00
Max 17892.00 0.00 0.00 0.00 0.00
Average 9366.00 0.00 0.00 0.00 0.00
Sum 56196.00 0.00 0.00 0.00 0.00


Heating SET Hours

SET ≤ 12.2°C Hours (°C) SET ≤ 12.2°C OccupantHours (°C) Longest SET ≤ 12.2°C Duration [hr] Start Time of the Longest SET ≤ 12.2°C Duration
None        


Cooling SET Hours

SET > 30°C Hours (°C) SET > 30°C OccupantHours (°C) Longest SET > 30°C Duration [hr] Start Time of the Longest SET > 30°C Duration
None        



Table of Contents

Report: Annual CO2 Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

CO2 Level Hours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      


CO2 Level OccupantHours

Safe (<= 1000 ppm) [hr] Caution (> 1000, <= 5000 ppm) [hr] Hazard (> 5000 ppm) [hr]
None      



Table of Contents

Report: Annual Visual Resilience Summary

For: Entire Facility

Timestamp: 2023-10-16 08:27:23

Illuminance Level Hours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
CORE_ZN 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 0.00 0.00 8760.00 0.00
PERIMETER_ZN_2 0.00 0.00 8760.00 0.00
PERIMETER_ZN_3 0.00 0.00 8760.00 0.00
PERIMETER_ZN_4 0.00 0.00 8760.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 8760.00 0.00
Average 0.00 0.00 5840.00 0.00
Sum 0.00 0.00 35040.00 0.00


Illuminance Level OccupantHours

A Bit Dark (<= 100 lux) [hr] Dim (> 100, <= 300 lux) [hr] Adequate (> 300, <= 500 lux) [hr] Bright (>500 lux) [hr]
CORE_ZN 0.00 0.00 0.00 0.00
PERIMETER_ZN_1 0.00 0.00 13356.00 0.00
PERIMETER_ZN_2 0.00 0.00 4788.00 0.00
PERIMETER_ZN_3 0.00 0.00 13356.00 0.00
PERIMETER_ZN_4 0.00 0.00 6804.00 0.00
ATTIC 0.00 0.00 0.00 0.00
Min 0.00 0.00 0.00 0.00
Max 0.00 0.00 13356.00 0.00
Average 0.00 0.00 6384.00 0.00
Sum 0.00 0.00 38304.00 0.00



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKPURPOSE PROGRESSINDICATOR

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODENAME ASHRAE901

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEYEAR 2019

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CODEAMENDMENT NONEAMEND

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY PROTOTYPENAME OFFICESMALL

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY TASKSCOPE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY STATE NATIONAL

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY CLIMATEZONE 4C

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: NAMEHOLDERMONTHLYSUMMARY REPRESENTCITY USA_WA_SEATTLE

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C]
January 4.496
February 5.822
March 8.326
April 10.851
May 12.973
June 15.587
July 17.665
August 18.800
September 15.086
October 11.426
November 8.070
December 5.416
   
Annual Sum or Average 11.241
Minimum of Months 4.496
Maximum of Months 18.800



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.455079E+09 1217.37 06-JAN-16:57 1.70 1.46 0.229022E+09 357.69 11-JAN-16:10 14.03 10.30
February 0.480576E+09 1272.68 10-FEB-08:70 0.78 -0.2 0.216219E+09 394.34 28-FEB-16:00 14.40 10.82
March 0.678353E+09 1303.25 01-MAR-07:05 -0.1 -1.7 0.288182E+09 402.33 10-MAR-16:40 13.73 11.38
April 0.716359E+09 3510.23 28-APR-05:03 11.10 9.92 0.267052E+09 402.35 28-APR-14:50 17.88 12.74
May 0.128444E+10 4062.88 16-MAY-05:03 11.70 10.43 0.310432E+09 402.36 16-MAY-14:39 17.20 12.90
June 0.168134E+10 4207.41 12-JUN-05:03 14.40 13.42 0.312024E+09 402.36 23-JUN-10:09 14.08 12.03
July 0.191621E+10 4049.99 19-JUL-05:02 11.57 9.58 0.284506E+09 402.36 11-JUL-13:39 11.57 9.58
August 0.233914E+10 4004.82 14-AUG-05:01 15.37 13.48 0.327323E+09 402.36 04-AUG-13:50 15.37 13.48
September 0.161600E+10 4046.27 11-SEP-05:02 12.12 10.60 0.283707E+09 402.36 01-SEP-09:50 12.12 10.60
October 0.100357E+10 4193.21 05-OCT-05:03 8.30 5.23 0.292097E+09 402.35 02-OCT-13:30 8.30 5.23
November 0.711514E+09 1274.58 08-NOV-16:05 9.90 8.67 0.260806E+09 402.35 06-NOV-16:30 9.90 8.67
December 0.556513E+09 1310.76 06-DEC-16:57 1.10 0.98 0.224300E+09 356.85 05-DEC-15:09 1.10 0.98
                     
Annual Sum or Average 0.134391E+11         0.329567E+10        
Minimum of Months 0.455079E+09 1217.37   -0.1 -1.7 0.216219E+09 356.85   1.10 0.98
Maximum of Months 0.233914E+10 4207.41   15.37 13.48 0.327323E+09 402.36   17.88 13.48



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 68161273.43 781.48 06-JAN-10:23 -0.9 -0.9 0.170542E+09 290.17 20-JAN-14:30 6.95 4.83
February 0.129511E+09 1187.42 27-FEB-15:20 19.80 12.26 0.163518E+09 304.99 27-FEB-16:00 18.90 12.17
March 0.278258E+09 1839.22 01-MAR-13:10 10.78 5.75 0.207694E+09 305.00 10-MAR-16:10 15.13 11.53
April 0.375284E+09 3118.21 27-APR-14:30 26.65 17.06 0.191814E+09 305.01 28-APR-14:09 18.22 12.85
May 0.560995E+09 2518.62 15-MAY-14:00 23.30 13.50 0.226586E+09 305.02 05-MAY-15:00 23.30 13.50
June 0.809862E+09 2549.15 28-JUN-14:00 25.00 15.65 0.232882E+09 305.01 29-JUN-15:39 17.60 13.26
July 0.128441E+10 6015.51 24-JUL-05:01 15.87 13.15 0.214766E+09 305.02 14-JUL-13:00 15.87 13.15
August 0.196770E+10 5859.42 09-AUG-05:02 14.97 12.17 0.247704E+09 305.02 04-AUG-14:09 14.97 12.17
September 0.141788E+10 5994.36 11-SEP-05:02 12.12 10.60 0.213437E+09 305.02 22-SEP-13:09 21.38 16.59
October 0.764031E+09 4527.86 04-OCT-13:50 21.02 11.37 0.213025E+09 305.00 06-OCT-15:09 17.30 12.22
November 0.195600E+09 1153.78 15-NOV-13:30 9.70 6.68 0.186416E+09 305.00 02-NOV-13:50 9.70 6.68
December 0.131451E+09 1055.86 05-DEC-14:30 10.30 6.71 0.166761E+09 304.99 05-DEC-15:00 6.10 4.53
                     
Annual Sum or Average 0.798315E+10         0.243514E+10        
Minimum of Months 68161273.43 781.48   -0.9 -0.9 0.163518E+09 290.17   6.10 4.53
Maximum of Months 0.196770E+10 6015.51   26.65 17.06 0.247704E+09 305.02   23.30 16.59



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 4338399.08 410.27 06-JAN-11:07 -0.4 -0.4 72573990.22 143.35 11-JAN-16:19 13.67 10.10
February 21375144.12 362.63 10-FEB-08:55 1.70 0.40 66734199.67 162.33 27-FEB-16:00 18.90 12.17
March 63138573.01 404.16 02-MAR-08:07 2.15 1.10 85165246.78 170.64 14-MAR-15:00 17.20 10.94
April 0.141676E+09 2929.47 28-APR-12:02 14.37 13.19 82799461.88 190.45 26-APR-14:09 14.37 13.19
May 0.319662E+09 3362.02 15-MAY-10:02 19.18 13.24 99191736.49 190.45 15-MAY-14:09 23.30 13.36
June 0.641799E+09 3320.67 28-JUN-10:02 21.20 14.55 0.102490E+09 190.45 02-JUN-14:09 21.20 14.55
July 0.838522E+09 3520.13 24-JUL-05:01 15.87 13.15 93996530.77 190.45 18-JUL-14:09 15.87 13.15
August 0.111695E+10 3495.28 14-AUG-09:04 19.35 15.19 0.108250E+09 190.45 28-AUG-14:09 23.25 16.35
September 0.574937E+09 3522.10 11-SEP-10:02 19.08 14.37 93012977.57 190.45 08-SEP-14:09 19.08 14.37
October 0.201040E+09 2636.45 04-OCT-10:02 17.48 10.97 90238646.44 190.45 04-OCT-14:09 21.20 11.42
November 57230921.26 392.55 13-NOV-11:07 3.07 2.87 77885650.66 176.84 02-NOV-14:00 3.07 2.87
December 15185003.67 344.03 12-DEC-11:05 5.10 4.65 69309267.57 142.81 05-DEC-13:00 5.10 4.65
                     
Annual Sum or Average 0.399585E+10         0.104165E+10        
Minimum of Months 4338399.08 344.03   -0.4 -0.4 66734199.67 142.81   3.07 2.87
Maximum of Months 0.111695E+10 3522.10   21.20 15.19 0.108250E+09 190.45   23.30 16.35



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 10646739.20 336.14 27-JAN-14:00 10.00 8.27 0.168192E+09 238.06 11-JAN-16:10 10.00 8.27
February 36241425.11 460.97 03-FEB-15:53 8.90 6.47 0.153586E+09 261.27 27-FEB-16:00 18.90 12.17
March 0.152017E+09 615.70 22-MAR-11:43 5.50 4.71 0.189620E+09 278.59 10-MAR-15:30 5.50 4.71
April 0.213956E+09 1057.36 27-APR-15:53 27.20 16.90 0.177699E+09 305.00 27-APR-14:39 27.20 16.90
May 0.452727E+09 1384.67 05-MAY-15:30 24.70 17.20 0.223645E+09 305.01 05-MAY-15:00 25.00 17.36
June 0.770892E+09 1870.71 28-JUN-15:53 26.10 16.29 0.233453E+09 305.01 29-JUN-15:09 17.30 13.30
July 0.104470E+10 3677.15 24-JUL-05:01 15.87 13.15 0.214836E+09 305.01 11-JUL-15:00 15.87 13.15
August 0.129957E+10 3488.98 09-AUG-05:02 14.97 12.17 0.247160E+09 305.01 16-AUG-15:30 19.15 15.97
September 0.682865E+09 1837.57 14-SEP-15:47 24.32 17.03 0.211714E+09 305.01 15-SEP-13:09 21.70 16.68
October 0.350307E+09 1082.37 04-OCT-15:57 21.10 11.40 0.199762E+09 305.00 06-OCT-15:09 17.30 12.22
November 0.180015E+09 661.96 30-NOV-13:55 4.40 3.92 0.177090E+09 285.26 03-NOV-15:00 4.40 3.92
December 26539502.75 703.40 21-DEC-16:53 3.90 2.27 0.160486E+09 232.89 29-DEC-16:10 10.40 8.63
                     
Annual Sum or Average 0.522047E+10         0.235724E+10        
Minimum of Months 10646739.20 336.14   3.90 2.27 0.153586E+09 232.89   4.40 3.92
Maximum of Months 0.129957E+10 3677.15   27.20 17.20 0.247160E+09 305.01   27.20 17.36



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 10807950.27 281.74 05-JAN-16:53 3.90 3.16 0.100091E+09 148.43 11-JAN-16:10 14.03 10.30
February 22285268.29 274.31 09-FEB-16:43 5.10 2.79 92856163.39 180.92 27-FEB-16:19 19.23 12.34
March 60886289.76 466.93 02-MAR-16:35 12.97 8.50 0.116923E+09 180.92 14-MAR-15:00 17.20 10.94
April 0.127008E+09 1640.48 27-APR-15:55 27.20 16.90 0.110937E+09 181.53 21-APR-13:20 27.20 16.90
May 0.363526E+09 2007.14 15-MAY-15:57 23.90 12.85 0.136358E+09 181.16 31-MAY-09:30 17.20 13.61
June 0.598461E+09 2564.69 23-JUN-05:02 13.80 11.92 0.139821E+09 180.94 23-JUN-10:09 14.08 12.03
July 0.894218E+09 4195.18 24-JUL-05:01 15.87 13.15 0.128551E+09 180.94 11-JUL-15:00 15.87 13.15
August 0.109163E+10 4086.99 15-AUG-05:02 13.05 11.44 0.147645E+09 180.94 30-AUG-14:39 24.00 16.72
September 0.625158E+09 4095.18 11-SEP-05:02 12.12 10.60 0.127175E+09 180.94 13-SEP-14:39 23.13 17.09
October 0.216259E+09 1854.56 04-OCT-15:57 21.10 11.40 0.123959E+09 180.93 06-OCT-13:50 17.12 11.98
November 57676710.73 259.85 09-NOV-08:15 6.87 6.13 0.107999E+09 180.90 02-NOV-14:50 6.87 6.13
December 24570769.22 377.38 06-DEC-17:00 1.10 0.98 95793982.37 154.47 01-DEC-15:00 1.10 0.98
                     
Annual Sum or Average 0.409249E+10         0.142811E+10        
Minimum of Months 10807950.27 259.85   1.10 0.98 92856163.39 148.43   1.10 0.98
Maximum of Months 0.109163E+10 4195.18   27.20 16.90 0.147645E+09 181.53   27.20 17.09



Table of Contents

Report: ZoneCoolingSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING ENERGY [J] ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] ZONE TOTAL INTERNAL LATENT GAIN ENERGY [J] ZONE TOTAL INTERNAL LATENT GAIN RATE {Maximum} [W] ZONE TOTAL INTERNAL LATENT GAIN RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 5.92 4.99 0.00 0.00 01-JAN-00:10 5.92 4.99
February 0.00 0.00 01-FEB-00:10 7.00 6.66 0.00 0.00 01-FEB-00:10 7.00 6.66
March 0.00 0.00 01-MAR-00:10 5.92 4.69 0.00 0.00 01-MAR-00:10 5.92 4.69
April 0.00 0.00 01-APR-00:10 7.93 7.13 0.00 0.00 01-APR-00:10 7.93 7.13
May 0.00 0.00 01-MAY-00:10 10.38 9.30 0.00 0.00 01-MAY-00:10 10.38 9.30
June 0.00 0.00 01-JUN-00:10 12.83 10.29 0.00 0.00 01-JUN-00:10 12.83 10.29
July 0.00 0.00 01-JUL-00:10 15.43 12.22 0.00 0.00 01-JUL-00:10 15.43 12.22
August 0.00 0.00 01-AUG-00:10 17.17 13.75 0.00 0.00 01-AUG-00:10 17.17 13.75
September 0.00 0.00 01-SEP-00:10 16.38 13.40 0.00 0.00 01-SEP-00:10 16.38 13.40
October 0.00 0.00 01-OCT-00:10 14.35 12.42 0.00 0.00 01-OCT-00:10 14.35 12.42
November 0.00 0.00 01-NOV-00:10 9.22 8.04 0.00 0.00 01-NOV-00:10 9.22 8.04
December 0.00 0.00 01-DEC-00:10 4.40 3.48 0.00 0.00 01-DEC-00:10 4.40 3.48
                     
Annual Sum or Average 0.00         0.00        
Minimum of Months 0.00 0.00   4.40 3.48 0.00 0.00   4.40 3.48
Maximum of Months 0.00 0.00   17.17 13.75 0.00 0.00   17.17 13.75



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.343744E+09 7165.29 23-JAN-06:01 3.98
February 0.131818E+09 7443.80 21-FEB-06:01 1.70
March 32438990.66 6188.26 27-MAR-05:01 4.32
April 21494085.88 434.51 27-APR-17:03 26.10
May 5940211.19 344.85 17-MAY-05:10 8.90
June 5416764.87 451.87 28-JUN-17:02 26.52
July 9574863.25 591.06 24-JUL-17:12 28.50
August 18723978.28 837.79 10-AUG-17:02 31.62
September 2457453.49 373.99 20-SEP-05:07 9.40
October 11579197.14 376.07 04-OCT-05:07 11.52
November 42145058.61 6582.65 28-NOV-06:01 4.32
December 0.137693E+09 7002.32 18-DEC-06:01 3.72
         
Annual Sum or Average 0.763025E+09      
Minimum of Months 2457453.49 344.85   1.70
Maximum of Months 0.343744E+09 7443.80   31.62



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.138723E+10 10395.23 23-JAN-06:01 3.98
February 0.744361E+09 10365.71 06-FEB-06:01 3.80
March 0.388011E+09 9866.92 14-MAR-05:01 4.40
April 0.202552E+09 9947.73 18-APR-05:01 3.30
May 61508338.65 2041.36 30-MAY-05:03 10.60
June 35700299.51 494.28 28-JUN-17:23 26.15
July 25959131.99 624.93 24-JUL-17:12 28.50
August 30684501.12 783.31 10-AUG-17:11 31.43
September 19120075.19 619.00 11-SEP-05:05 12.12
October 59840118.59 4547.06 23-OCT-05:03 10.60
November 0.419302E+09 10172.35 28-NOV-06:01 4.32
December 0.929919E+09 10351.38 18-DEC-06:01 3.72
         
Annual Sum or Average 0.430418E+10      
Minimum of Months 19120075.19 494.28   3.30
Maximum of Months 0.138723E+10 10395.23   31.43



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.857340E+09 6210.38 23-JAN-06:01 3.98
February 0.521618E+09 6191.90 06-FEB-06:01 3.80
March 0.227407E+09 6058.43 27-MAR-05:01 4.32
April 82645642.73 5886.98 18-APR-05:01 3.30
May 22283015.03 2327.06 30-MAY-05:03 10.60
June 15196443.72 284.95 28-JUN-17:23 26.15
July 14296015.96 366.17 24-JUL-17:12 28.50
August 17532551.63 467.74 10-AUG-17:11 31.43
September 15372119.55 344.76 11-SEP-05:03 12.12
October 30629497.06 4101.97 23-OCT-05:03 10.60
November 0.214088E+09 6002.67 28-NOV-06:01 4.32
December 0.542086E+09 6184.70 18-DEC-06:01 3.72
         
Annual Sum or Average 0.256049E+10      
Minimum of Months 14296015.96 284.95   3.30
Maximum of Months 0.857340E+09 6210.38   31.43



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.138286E+10 6834.67 09-JAN-06:01 -1.5
February 0.946852E+09 6915.69 13-FEB-06:01 2.30
March 0.449054E+09 6361.60 27-MAR-05:01 4.32
April 0.176172E+09 6021.15 18-APR-05:01 3.30
May 23598946.26 3015.91 30-MAY-05:03 10.60
June 19807526.46 368.98 28-JUN-17:02 26.52
July 14876147.61 470.55 24-JUL-17:12 28.50
August 21354200.09 651.63 10-AUG-17:02 31.62
September 16083443.27 287.33 14-SEP-05:04 12.62
October 47577243.68 4358.10 23-OCT-05:03 10.60
November 0.361202E+09 6323.11 13-NOV-06:01 1.70
December 0.893013E+09 6849.56 26-DEC-06:01 -0.8
         
Annual Sum or Average 0.435245E+10      
Minimum of Months 14876147.61 287.33   -1.5
Maximum of Months 0.138286E+10 6915.69   31.62



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.855856E+09 6859.03 23-JAN-06:01 3.98
February 0.530124E+09 6838.35 06-FEB-06:01 3.80
March 0.240607E+09 6902.73 27-MAR-05:01 4.32
April 91487866.87 6763.66 12-APR-05:01 3.80
May 23924872.48 460.10 18-MAY-05:05 5.60
June 19297108.28 385.37 23-JUN-05:04 13.80
July 11315191.97 436.55 28-JUL-05:04 14.50
August 17346236.70 475.35 29-AUG-17:12 30.73
September 13835114.92 435.26 12-SEP-05:04 12.12
October 31386987.43 4587.95 31-OCT-05:02 8.58
November 0.214172E+09 6872.96 28-NOV-06:01 4.32
December 0.533701E+09 6841.32 08-DEC-06:01 4.40
         
Annual Sum or Average 0.258305E+10      
Minimum of Months 11315191.97 385.37   3.80
Maximum of Months 0.855856E+09 6902.73   30.73



Table of Contents

Report: ZoneHeatingSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE HEATING ENERGY [J] ZONE AIR SYSTEM SENSIBLE HEATING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE HEATING RATE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C]
January 0.00 0.00 01-JAN-00:10 5.92
February 0.00 0.00 01-FEB-00:10 7.00
March 0.00 0.00 01-MAR-00:10 5.92
April 0.00 0.00 01-APR-00:10 7.93
May 0.00 0.00 01-MAY-00:10 10.38
June 0.00 0.00 01-JUN-00:10 12.83
July 0.00 0.00 01-JUL-00:10 15.43
August 0.00 0.00 01-AUG-00:10 17.17
September 0.00 0.00 01-SEP-00:10 16.38
October 0.00 0.00 01-OCT-00:10 14.35
November 0.00 0.00 01-NOV-00:10 9.22
December 0.00 0.00 01-DEC-00:10 4.40
         
Annual Sum or Average 0.00      
Minimum of Months 0.00 0.00   4.40
Maximum of Months 0.00 0.00   17.17



Table of Contents

Report: ZoneElectricSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.729889E+09 743.94 02-JAN-08:09 0.118664E+10 973.59 02-JAN-08:09
February 0.660244E+09 743.94 01-FEB-08:09 0.107295E+10 973.59 01-FEB-08:09
March 0.791184E+09 743.94 01-MAR-08:09 0.125726E+10 973.59 01-MAR-08:09
April 0.696458E+09 743.94 03-APR-07:10 0.113787E+10 973.59 03-APR-07:10
May 0.760537E+09 743.94 01-MAY-07:10 0.122195E+10 973.59 01-MAY-07:10
June 0.757753E+09 743.94 01-JUN-07:10 0.120670E+10 973.59 01-JUN-07:10
July 0.699242E+09 743.94 03-JUL-07:10 0.115223E+10 973.59 03-JUL-07:10
August 0.791184E+09 743.94 01-AUG-07:10 0.125726E+10 973.59 01-AUG-07:10
September 0.696458E+09 743.94 01-SEP-07:10 0.113608E+10 973.59 01-SEP-07:10
October 0.729889E+09 743.94 02-OCT-07:10 0.118754E+10 973.59 02-OCT-07:10
November 0.727106E+09 743.94 01-NOV-07:10 0.117228E+10 973.59 01-NOV-07:10
December 0.699242E+09 743.94 01-DEC-08:09 0.115133E+10 973.59 01-DEC-08:09
             
Annual Sum or Average 0.873919E+10     0.141401E+11    
Minimum of Months 0.660244E+09 743.94   0.107295E+10 973.59  
Maximum of Months 0.791184E+09 743.94   0.125726E+10 973.59  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.486783E+09 563.96 02-JAN-16:30 0.899552E+09 738.04 02-JAN-08:09
February 0.420794E+09 554.16 15-FEB-16:00 0.813362E+09 738.04 01-FEB-08:09
March 0.491202E+09 546.24 22-MAR-07:10 0.953087E+09 738.04 01-MAR-08:09
April 0.424087E+09 532.06 03-APR-07:10 0.862580E+09 738.04 03-APR-07:10
May 0.457631E+09 508.87 17-MAY-07:10 0.926320E+09 738.04 01-MAY-07:10
June 0.451955E+09 502.34 29-JUN-07:10 0.914754E+09 738.04 01-JUN-07:10
July 0.422475E+09 526.20 12-JUL-07:30 0.873466E+09 738.04 03-JUL-07:10
August 0.476958E+09 526.27 02-AUG-07:30 0.953087E+09 738.04 01-AUG-07:10
September 0.429209E+09 546.98 25-SEP-07:10 0.861220E+09 738.04 01-SEP-07:10
October 0.461622E+09 562.69 31-OCT-07:10 0.900233E+09 738.04 02-OCT-07:10
November 0.482084E+09 563.96 06-NOV-16:49 0.888667E+09 738.04 01-NOV-07:10
December 0.472675E+09 563.96 01-DEC-16:19 0.872785E+09 738.04 01-DEC-08:09
             
Annual Sum or Average 0.547748E+10     0.107191E+11    
Minimum of Months 0.420794E+09 502.34   0.813362E+09 738.04  
Maximum of Months 0.491202E+09 563.96   0.953087E+09 738.04  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.298939E+09 334.55 02-JAN-16:30 0.533626E+09 437.82 02-JAN-08:09
February 0.260451E+09 330.57 02-FEB-16:00 0.482497E+09 437.82 01-FEB-08:09
March 0.300717E+09 323.89 22-MAR-07:10 0.565383E+09 437.82 01-MAR-08:09
April 0.257238E+09 313.59 03-APR-07:10 0.511694E+09 437.82 03-APR-07:10
May 0.275472E+09 297.30 17-MAY-07:10 0.549505E+09 437.82 01-MAY-07:10
June 0.273733E+09 298.06 14-JUN-15:30 0.542644E+09 437.82 01-JUN-07:10
July 0.255027E+09 306.02 12-JUL-08:30 0.518151E+09 437.82 03-JUL-07:10
August 0.290950E+09 311.22 02-AUG-07:30 0.565383E+09 437.82 01-AUG-07:10
September 0.262060E+09 324.34 25-SEP-07:10 0.510887E+09 437.82 01-SEP-07:10
October 0.284941E+09 333.81 31-OCT-07:10 0.534030E+09 437.82 02-OCT-07:10
November 0.295427E+09 334.55 06-NOV-16:49 0.527169E+09 437.82 01-NOV-07:10
December 0.289008E+09 334.55 01-DEC-16:19 0.517747E+09 437.82 01-DEC-08:09
             
Annual Sum or Average 0.334396E+10     0.635872E+10    
Minimum of Months 0.255027E+09 297.30   0.482497E+09 437.82  
Maximum of Months 0.300717E+09 334.55   0.565383E+09 437.82  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.524969E+09 563.96 02-JAN-16:30 0.899552E+09 738.04 02-JAN-08:09
February 0.462737E+09 556.43 02-FEB-16:00 0.813362E+09 738.04 01-FEB-08:09
March 0.530727E+09 548.38 22-MAR-07:10 0.953087E+09 738.04 01-MAR-08:09
April 0.444120E+09 535.82 03-APR-07:10 0.862580E+09 738.04 03-APR-07:10
May 0.464085E+09 512.95 17-MAY-07:10 0.926320E+09 738.04 01-MAY-07:10
June 0.458826E+09 504.61 16-JUN-07:10 0.914754E+09 738.04 01-JUN-07:10
July 0.434171E+09 532.74 12-JUL-08:30 0.873466E+09 738.04 03-JUL-07:10
August 0.501625E+09 529.91 02-AUG-07:30 0.953087E+09 738.04 01-AUG-07:10
September 0.459011E+09 548.86 25-SEP-07:10 0.861220E+09 738.04 01-SEP-07:10
October 0.505425E+09 562.98 31-OCT-07:10 0.900233E+09 738.04 02-OCT-07:10
November 0.520037E+09 563.96 06-NOV-16:49 0.888667E+09 738.04 01-NOV-07:10
December 0.506895E+09 563.96 01-DEC-16:19 0.872785E+09 738.04 01-DEC-08:09
             
Annual Sum or Average 0.581263E+10     0.107191E+11    
Minimum of Months 0.434171E+09 504.61   0.813362E+09 738.04  
Maximum of Months 0.530727E+09 563.96   0.953087E+09 738.04  



Table of Contents

Report: ZoneElectricSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE LIGHTS ELECTRICITY ENERGY [J] ZONE LIGHTS ELECTRICITY ENERGY {Maximum} [W] ZONE LIGHTS ELECTRICITY ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY [J] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT ELECTRICITY ENERGY {TIMESTAMP}
January 0.298780E+09 334.55 02-JAN-16:30 0.533626E+09 437.82 02-JAN-08:09
February 0.259927E+09 329.15 02-FEB-08:09 0.482497E+09 437.82 01-FEB-08:09
March 0.302030E+09 325.78 22-MAR-07:10 0.565383E+09 437.82 01-MAR-08:09
April 0.258741E+09 319.97 03-APR-07:10 0.511694E+09 437.82 03-APR-07:10
May 0.275876E+09 309.20 17-MAY-07:10 0.549505E+09 437.82 01-MAY-07:10
June 0.273731E+09 306.33 29-JUN-07:10 0.542644E+09 437.82 01-JUN-07:10
July 0.255700E+09 320.49 12-JUL-07:30 0.518151E+09 437.82 03-JUL-07:10
August 0.291676E+09 319.47 28-AUG-07:30 0.565383E+09 437.82 01-AUG-07:10
September 0.262489E+09 326.04 25-SEP-07:10 0.510887E+09 437.82 01-SEP-07:10
October 0.285112E+09 333.97 31-OCT-07:10 0.534030E+09 437.82 02-OCT-07:10
November 0.296382E+09 334.55 06-NOV-16:49 0.527169E+09 437.82 01-NOV-07:10
December 0.289362E+09 334.55 01-DEC-16:19 0.517747E+09 437.82 01-DEC-08:09
             
Annual Sum or Average 0.334980E+10     0.635872E+10    
Minimum of Months 0.255700E+09 306.33   0.482497E+09 437.82  
Maximum of Months 0.302030E+09 334.55   0.565383E+09 437.82  



Table of Contents

Report: SpaceGainsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 0.711734E+09 0.729889E+09 0.118664E+10 0.00 0.00 0.00 0.00 0.00 0.00
February 0.643949E+09 0.660244E+09 0.107295E+10 0.00 0.00 0.00 0.00 0.00 0.00
March 0.779518E+09 0.791184E+09 0.125726E+10 0.00 0.00 0.00 0.00 0.00 0.00
April 0.677841E+09 0.696458E+09 0.113787E+10 0.00 0.00 0.00 0.00 0.00 0.00
May 0.745626E+09 0.760537E+09 0.122195E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.745626E+09 0.757753E+09 0.120670E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.677841E+09 0.699242E+09 0.115223E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.779518E+09 0.791184E+09 0.125726E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.677841E+09 0.696458E+09 0.113608E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.711734E+09 0.729889E+09 0.118754E+10 0.00 0.00 0.00 0.00 0.00 0.00
November 0.711734E+09 0.727106E+09 0.117228E+10 0.00 0.00 0.00 0.00 0.00 0.00
December 0.677841E+09 0.699242E+09 0.115133E+10 0.00 0.00 0.00 0.00 0.00 0.00
                   
Annual Sum or Average 0.854080E+10 0.873919E+10 0.141401E+11 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.643949E+09 0.660244E+09 0.107295E+10 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.779518E+09 0.791184E+09 0.125726E+10 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.539540E+09 0.486783E+09 0.899552E+09 0.00 0.00 0.00 0.00 0.00 0.808466E+09
February 0.488155E+09 0.420794E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 0.700498E+09
March 0.590925E+09 0.491202E+09 0.953087E+09 0.00 0.00 0.00 0.00 0.00 0.717912E+09
April 0.513848E+09 0.424087E+09 0.862580E+09 0.00 0.00 0.00 0.00 2183749.98 0.585992E+09
May 0.565233E+09 0.457631E+09 0.926320E+09 0.00 0.00 0.00 0.00 268508.08 0.517764E+09
June 0.565233E+09 0.451955E+09 0.914754E+09 0.00 0.00 0.00 0.00 2004734.69 0.414823E+09
July 0.513848E+09 0.422475E+09 0.873466E+09 0.00 0.00 0.00 0.00 11635415.24 0.304600E+09
August 0.590925E+09 0.476958E+09 0.953087E+09 0.00 0.00 0.00 0.00 31428473.19 0.288473E+09
September 0.513848E+09 0.429209E+09 0.861220E+09 0.00 0.00 0.00 0.00 497557.37 0.336998E+09
October 0.539540E+09 0.461622E+09 0.900233E+09 0.00 0.00 0.00 0.00 0.00 0.591486E+09
November 0.539540E+09 0.482084E+09 0.888667E+09 0.00 0.00 0.00 0.00 0.00 0.687615E+09
December 0.513848E+09 0.472675E+09 0.872785E+09 0.00 0.00 0.00 0.00 0.00 0.745365E+09
                   
Annual Sum or Average 0.647448E+10 0.547748E+10 0.107191E+11 0.00 0.00 0.00 0.00 48018438.54 0.669999E+10
Minimum of Months 0.488155E+09 0.420794E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 0.288473E+09
Maximum of Months 0.590925E+09 0.491202E+09 0.953087E+09 0.00 0.00 0.00 0.00 31428473.19 0.808466E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.234287E+09 0.298939E+09 0.533626E+09 0.00 0.00 0.00 0.00 0.00 0.204510E+09
February 0.211974E+09 0.260451E+09 0.482497E+09 0.00 0.00 0.00 0.00 0.00 0.180453E+09
March 0.256600E+09 0.300717E+09 0.565383E+09 0.00 0.00 0.00 0.00 0.00 0.177395E+09
April 0.223130E+09 0.257238E+09 0.511694E+09 0.00 0.00 0.00 0.00 636007.03 0.171093E+09
May 0.245443E+09 0.275472E+09 0.549505E+09 0.00 0.00 0.00 0.00 13836.23 0.150185E+09
June 0.245443E+09 0.273733E+09 0.542644E+09 0.00 0.00 0.00 0.00 95397.93 0.129301E+09
July 0.223130E+09 0.255027E+09 0.518151E+09 0.00 0.00 0.00 0.00 757042.37 0.106880E+09
August 0.256600E+09 0.290950E+09 0.565383E+09 0.00 0.00 0.00 0.00 1982922.71 95172220.49
September 0.223130E+09 0.262060E+09 0.510887E+09 0.00 0.00 0.00 0.00 13063.81 72824699.26
October 0.234287E+09 0.284941E+09 0.534030E+09 0.00 0.00 0.00 0.00 0.00 0.160971E+09
November 0.234287E+09 0.295427E+09 0.527169E+09 0.00 0.00 0.00 0.00 0.00 0.170806E+09
December 0.223130E+09 0.289008E+09 0.517747E+09 0.00 0.00 0.00 0.00 0.00 0.175951E+09
                   
Annual Sum or Average 0.281144E+10 0.334396E+10 0.635872E+10 0.00 0.00 0.00 0.00 3498270.08 0.179554E+10
Minimum of Months 0.211974E+09 0.255027E+09 0.482497E+09 0.00 0.00 0.00 0.00 0.00 72824699.26
Maximum of Months 0.256600E+09 0.300717E+09 0.565383E+09 0.00 0.00 0.00 0.00 1982922.71 0.204510E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.539540E+09 0.524969E+09 0.899552E+09 0.00 0.00 0.00 0.00 0.00 0.308030E+09
February 0.488155E+09 0.462737E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 0.269400E+09
March 0.590925E+09 0.530727E+09 0.953087E+09 0.00 0.00 0.00 0.00 373.05 0.260089E+09
April 0.513848E+09 0.444120E+09 0.862580E+09 0.00 0.00 0.00 0.00 1258535.40 0.245034E+09
May 0.565233E+09 0.464085E+09 0.926320E+09 0.00 0.00 0.00 0.00 22456.20 0.217042E+09
June 0.565233E+09 0.458826E+09 0.914754E+09 0.00 0.00 0.00 0.00 152330.38 0.184847E+09
July 0.513848E+09 0.434171E+09 0.873466E+09 0.00 0.00 0.00 0.00 2182367.46 0.154734E+09
August 0.590925E+09 0.501625E+09 0.953087E+09 0.00 0.00 0.00 0.00 3579935.27 0.134420E+09
September 0.513848E+09 0.459011E+09 0.861220E+09 0.00 0.00 0.00 0.00 20848.59 0.104039E+09
October 0.539540E+09 0.505425E+09 0.900233E+09 0.00 0.00 0.00 0.00 0.00 0.232751E+09
November 0.539540E+09 0.520037E+09 0.888667E+09 0.00 0.00 0.00 0.00 0.00 0.254774E+09
December 0.513848E+09 0.506895E+09 0.872785E+09 0.00 0.00 0.00 0.00 0.00 0.264474E+09
                   
Annual Sum or Average 0.647448E+10 0.581263E+10 0.107191E+11 0.00 0.00 0.00 0.00 7216846.35 0.262963E+10
Minimum of Months 0.488155E+09 0.434171E+09 0.813362E+09 0.00 0.00 0.00 0.00 0.00 0.104039E+09
Maximum of Months 0.590925E+09 0.530727E+09 0.953087E+09 0.00 0.00 0.00 0.00 3579935.27 0.308030E+09



Table of Contents

Report: SpaceGainsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [J] ZONE LIGHTS TOTAL HEATING ENERGY [J] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [J] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.320062E+09 0.298780E+09 0.533626E+09 0.00 0.00 0.00 0.00 0.00 0.205798E+09
February 0.289580E+09 0.259927E+09 0.482497E+09 0.00 0.00 0.00 0.00 0.00 0.181953E+09
March 0.350544E+09 0.302030E+09 0.565383E+09 0.00 0.00 0.00 0.00 0.00 0.179776E+09
April 0.304821E+09 0.258741E+09 0.511694E+09 0.00 0.00 0.00 0.00 459548.04 0.171872E+09
May 0.335303E+09 0.275876E+09 0.549505E+09 0.00 0.00 0.00 0.00 14973.53 0.155370E+09
June 0.335303E+09 0.273731E+09 0.542644E+09 0.00 0.00 0.00 0.00 97831.92 0.130835E+09
July 0.304821E+09 0.255700E+09 0.518151E+09 0.00 0.00 0.00 0.00 735854.46 0.116023E+09
August 0.350544E+09 0.291676E+09 0.565383E+09 0.00 0.00 0.00 0.00 1874384.57 99832029.43
September 0.304821E+09 0.262489E+09 0.510887E+09 0.00 0.00 0.00 0.00 13810.07 75771864.61
October 0.320062E+09 0.285112E+09 0.534030E+09 0.00 0.00 0.00 0.00 0.00 0.163137E+09
November 0.320062E+09 0.296382E+09 0.527169E+09 0.00 0.00 0.00 0.00 0.00 0.172361E+09
December 0.304821E+09 0.289362E+09 0.517747E+09 0.00 0.00 0.00 0.00 0.00 0.177142E+09
                   
Annual Sum or Average 0.384075E+10 0.334980E+10 0.635872E+10 0.00 0.00 0.00 0.00 3196402.58 0.182987E+10
Minimum of Months 0.289580E+09 0.255700E+09 0.482497E+09 0.00 0.00 0.00 0.00 0.00 75771864.61
Maximum of Months 0.350544E+09 0.302030E+09 0.565383E+09 0.00 0.00 0.00 0.00 1874384.57 0.205798E+09



Table of Contents

Report: SpaceGainsMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [J] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.933740E+09 0.704671E+09
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.825696E+09 0.126070E+10
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.792869E+09 0.218954E+10
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.632860E+09 0.337159E+10
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.588010E+09 0.449560E+10
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.534881E+09 0.454967E+10
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.582549E+09 0.483380E+10
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.679214E+09 0.375844E+10
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.891050E+09 0.291170E+10
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.868993E+09 0.165625E+10
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.834784E+09 0.858700E+09
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.111056E+10 0.572177E+09
                   
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.927520E+10 0.311629E+11
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.534881E+09 0.572177E+09
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.111056E+10 0.483380E+10



Table of Contents

Report: PeakSpaceGainsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 966.54 02-JAN-08:09 743.94 02-JAN-08:09 973.59 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 0.00
February 966.54 01-FEB-08:09 743.94 01-FEB-08:09 973.59 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 0.00
March 966.54 01-MAR-08:09 743.94 01-MAR-08:09 973.59 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 0.00
April 966.54 03-APR-07:10 743.94 03-APR-07:10 973.59 03-APR-07:10 0.00 0.00 0.00 0.00 0.00 0.00
May 966.54 01-MAY-07:10 743.94 01-MAY-07:10 973.59 01-MAY-07:10 0.00 0.00 0.00 0.00 0.00 0.00
June 966.54 01-JUN-07:10 743.94 01-JUN-07:10 973.59 01-JUN-07:10 0.00 0.00 0.00 0.00 0.00 0.00
July 966.54 03-JUL-07:10 743.94 03-JUL-07:10 973.59 03-JUL-07:10 0.00 0.00 0.00 0.00 0.00 0.00
August 966.54 01-AUG-07:10 743.94 01-AUG-07:10 973.59 01-AUG-07:10 0.00 0.00 0.00 0.00 0.00 0.00
September 966.54 01-SEP-07:10 743.94 01-SEP-07:10 973.59 01-SEP-07:10 0.00 0.00 0.00 0.00 0.00 0.00
October 966.54 02-OCT-07:10 743.94 02-OCT-07:10 973.59 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 0.00
November 966.54 01-NOV-07:10 743.94 01-NOV-07:10 973.59 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 0.00
December 966.54 01-DEC-08:09 743.94 01-DEC-08:09 973.59 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average             0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 966.54   743.94   973.59   0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 966.54   743.94   973.59   0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 732.70 02-JAN-08:09 563.96 02-JAN-16:30 738.04 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 2383.39 06-JAN-08:00
February 732.70 01-FEB-08:09 554.16 15-FEB-16:00 738.04 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 2234.98 09-FEB-08:00
March 732.70 01-MAR-08:09 546.24 22-MAR-07:10 738.04 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 2136.47 01-MAR-07:10
April 732.70 03-APR-07:10 532.06 03-APR-07:10 738.04 03-APR-07:10 0.00 0.00 0.00 0.00 287.56 27-APR-16:10 1881.00 19-APR-06:10
May 732.70 01-MAY-07:10 508.87 17-MAY-07:10 738.04 01-MAY-07:10 0.00 0.00 0.00 0.00 68.42 05-MAY-16:10 1540.22 11-MAY-06:03
June 732.70 01-JUN-07:10 502.34 29-JUN-07:10 738.04 01-JUN-07:10 0.00 0.00 0.00 0.00 258.44 28-JUN-17:00 1237.59 15-JUN-06:03
July 732.70 03-JUL-07:10 526.20 12-JUL-07:30 738.04 03-JUL-07:10 0.00 0.00 0.00 0.00 453.74 31-JUL-16:05 1099.53 03-JUL-06:05
August 732.70 01-AUG-07:10 526.27 02-AUG-07:30 738.04 01-AUG-07:10 0.00 0.00 0.00 0.00 706.09 10-AUG-17:00 1210.25 01-AUG-06:03
September 732.70 01-SEP-07:10 546.98 25-SEP-07:10 738.04 01-SEP-07:10 0.00 0.00 0.00 0.00 102.66 14-SEP-17:00 1360.68 27-SEP-06:03
October 732.70 02-OCT-07:10 562.69 31-OCT-07:10 738.04 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 1602.12 13-OCT-06:03
November 732.70 01-NOV-07:10 563.96 06-NOV-16:49 738.04 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 2027.56 13-NOV-08:00
December 732.70 01-DEC-08:09 563.96 01-DEC-16:19 738.04 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 2312.00 26-DEC-07:10
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 732.70   502.34   738.04   0.00 0.00 0.00 0.00 0.00   1099.53  
Maximum of Months 732.70   563.96   738.04   0.00 0.00 0.00 0.00 706.09   2383.39  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 434.65 02-JAN-08:09 334.55 02-JAN-16:30 437.82 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 295.39 12-JAN-24:00
February 434.65 01-FEB-08:09 330.57 02-FEB-16:00 437.82 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 283.28 16-FEB-07:00
March 434.65 01-MAR-08:09 323.89 22-MAR-07:10 437.82 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 281.57 29-MAR-05:03
April 434.65 03-APR-07:10 313.59 03-APR-07:10 437.82 03-APR-07:10 0.00 0.00 0.00 0.00 67.51 01-APR-17:03 285.14 07-APR-24:00
May 434.65 01-MAY-07:10 297.30 17-MAY-07:10 437.82 01-MAY-07:10 0.00 0.00 0.00 0.00 1.47 05-MAY-16:00 283.75 17-MAY-18:55
June 434.65 01-JUN-07:10 298.06 14-JUN-15:30 437.82 01-JUN-07:10 0.00 0.00 0.00 0.00 5.17 28-JUN-15:57 298.83 13-JUN-03:00
July 434.65 03-JUL-07:10 306.02 12-JUL-08:30 437.82 03-JUL-07:10 0.00 0.00 0.00 0.00 16.44 24-JUL-18:10 146.31 02-JUL-04:00
August 434.65 01-AUG-07:10 311.22 02-AUG-07:30 437.82 01-AUG-07:10 0.00 0.00 0.00 0.00 34.35 29-AUG-18:10 227.56 11-AUG-04:00
September 434.65 01-SEP-07:10 324.34 25-SEP-07:10 437.82 01-SEP-07:10 0.00 0.00 0.00 0.00 1.76 14-SEP-17:00 138.30 18-SEP-23:00
October 434.65 02-OCT-07:10 333.81 31-OCT-07:10 437.82 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 268.83 31-OCT-20:00
November 434.65 01-NOV-07:10 334.55 06-NOV-16:49 437.82 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 317.88 29-NOV-21:00
December 434.65 01-DEC-08:09 334.55 01-DEC-16:19 437.82 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 292.00 26-DEC-19:02
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 434.65   297.30   437.82   0.00 0.00 0.00 0.00 0.00   138.30  
Maximum of Months 434.65   334.55   437.82   0.00 0.00 0.00 0.00 67.51   317.88  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 732.70 02-JAN-08:09 563.96 02-JAN-16:30 738.04 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 448.27 12-JAN-24:00
February 732.70 01-FEB-08:09 556.43 02-FEB-16:00 738.04 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 424.93 16-FEB-07:00
March 732.70 01-MAR-08:09 548.38 22-MAR-07:10 738.04 01-MAR-08:09 0.00 0.00 0.00 0.00 0.54 18-MAR-15:53 421.92 29-MAR-05:06
April 732.70 03-APR-07:10 535.82 03-APR-07:10 738.04 03-APR-07:10 0.00 0.00 0.00 0.00 117.68 01-APR-17:03 406.47 07-APR-24:00
May 732.70 01-MAY-07:10 512.95 17-MAY-07:10 738.04 01-MAY-07:10 0.00 0.00 0.00 0.00 2.20 05-MAY-16:00 422.47 17-MAY-18:55
June 732.70 01-JUN-07:10 504.61 16-JUN-07:10 738.04 01-JUN-07:10 0.00 0.00 0.00 0.00 7.75 28-JUN-15:57 438.44 13-JUN-03:00
July 732.70 03-JUL-07:10 532.74 12-JUL-08:30 738.04 03-JUL-07:10 0.00 0.00 0.00 0.00 50.64 23-JUL-14:00 219.21 02-JUL-04:00
August 732.70 01-AUG-07:10 529.91 02-AUG-07:30 738.04 01-AUG-07:10 0.00 0.00 0.00 0.00 58.13 29-AUG-18:10 332.33 11-AUG-04:00
September 732.70 01-SEP-07:10 548.86 25-SEP-07:10 738.04 01-SEP-07:10 0.00 0.00 0.00 0.00 2.63 14-SEP-17:00 206.71 18-SEP-23:20
October 732.70 02-OCT-07:10 562.98 31-OCT-07:10 738.04 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 401.55 31-OCT-20:00
November 732.70 01-NOV-07:10 563.96 06-NOV-16:49 738.04 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 481.93 29-NOV-21:00
December 732.70 01-DEC-08:09 563.96 01-DEC-16:19 738.04 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 438.66 26-DEC-19:02
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 732.70   504.61   738.04   0.00 0.00 0.00 0.00 0.00   206.71  
Maximum of Months 732.70   563.96   738.04   0.00 0.00 0.00 0.00 117.68   481.93  



Table of Contents

Report: PeakSpaceGainsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY {Maximum} [W] ZONE PEOPLE TOTAL HEATING ENERGY {TIMESTAMP} ZONE LIGHTS TOTAL HEATING ENERGY {Maximum} [W] ZONE LIGHTS TOTAL HEATING ENERGY {TIMESTAMP} ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {Maximum} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {TIMESTAMP} ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 434.65 02-JAN-08:09 334.55 02-JAN-16:30 437.82 02-JAN-08:09 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 296.71 12-JAN-24:00
February 434.65 01-FEB-08:09 329.15 02-FEB-08:09 437.82 01-FEB-08:09 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 288.49 16-FEB-06:04
March 434.65 01-MAR-08:09 325.78 22-MAR-07:10 437.82 01-MAR-08:09 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 287.04 29-MAR-05:03
April 434.65 03-APR-07:10 319.97 03-APR-07:10 437.82 03-APR-07:10 0.00 0.00 0.00 0.00 46.39 01-APR-17:03 274.16 07-APR-24:00
May 434.65 01-MAY-07:10 309.20 17-MAY-07:10 437.82 01-MAY-07:10 0.00 0.00 0.00 0.00 1.47 05-MAY-16:00 287.51 17-MAY-18:55
June 434.65 01-JUN-07:10 306.33 29-JUN-07:10 437.82 01-JUN-07:10 0.00 0.00 0.00 0.00 5.17 28-JUN-15:57 289.72 13-JUN-03:00
July 434.65 03-JUL-07:10 320.49 12-JUL-07:30 437.82 03-JUL-07:10 0.00 0.00 0.00 0.00 17.31 23-JUL-14:00 151.45 02-JUL-04:00
August 434.65 01-AUG-07:10 319.47 28-AUG-07:30 437.82 01-AUG-07:10 0.00 0.00 0.00 0.00 27.93 29-AUG-18:10 238.75 11-AUG-04:00
September 434.65 01-SEP-07:10 326.04 25-SEP-07:10 437.82 01-SEP-07:10 0.00 0.00 0.00 0.00 1.76 14-SEP-17:00 142.08 30-SEP-06:00
October 434.65 02-OCT-07:10 333.97 31-OCT-07:10 437.82 02-OCT-07:10 0.00 0.00 0.00 0.00 0.00 01-OCT-00:10 271.66 31-OCT-20:00
November 434.65 01-NOV-07:10 334.55 06-NOV-16:49 437.82 01-NOV-07:10 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 319.07 29-NOV-21:00
December 434.65 01-DEC-08:09 334.55 01-DEC-16:19 437.82 01-DEC-08:09 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 292.12 26-DEC-19:02
                             
Annual Sum or Average             0.00 0.00 0.00 0.00        
Minimum of Months 434.65   306.33   437.82   0.00 0.00 0.00 0.00 0.00   142.08  
Maximum of Months 434.65   334.55   437.82   0.00 0.00 0.00 0.00 46.39   319.07  



Table of Contents

Report: PeakSpaceGainsMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {TIMESTAMP} ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {Maximum} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {TIMESTAMP}
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1271.68 09-JAN-03:00 2727.91 20-JAN-13:30
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1586.95 27-FEB-03:55 3627.05 08-FEB-13:20
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1450.83 01-MAR-07:53 5367.88 14-MAR-13:20
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1260.73 27-APR-05:45 6112.60 18-APR-12:50
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1251.40 15-MAY-03:00 7254.61 31-MAY-13:30
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1231.01 10-JUN-02:00 6460.12 22-JUN-13:00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1334.90 08-JUL-03:00 6567.50 13-JUL-13:30
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1315.67 09-AUG-05:35 6007.27 06-AUG-12:00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1513.27 10-SEP-05:00 5579.39 07-SEP-13:00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1314.74 04-OCT-22:00 4067.36 11-OCT-12:20
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1408.91 11-NOV-24:00 2939.98 04-NOV-13:20
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1740.02 06-DEC-04:00 2239.91 06-DEC-12:20
                       
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00        
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1231.01   2239.91  
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1740.02   7254.61  



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY [] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY []
January 1217.37 06-JAN-16:57 2899.62 2231.82 2920.76 0.00 0.00 0.00 0.00 0.00 0.00
February 1272.68 10-FEB-08:70 966.54 743.94 973.59 0.00 0.00 0.00 0.00 0.00 0.00
March 1303.25 01-MAR-07:05 405.95 694.33 973.59 0.00 0.00 0.00 0.00 0.00 0.00
April 3510.23 28-APR-05:03 318.96 96.65 1460.38 0.00 0.00 0.00 0.00 0.00 0.00
May 4062.88 16-MAY-05:03 318.96 96.65 1460.38 0.00 0.00 0.00 0.00 0.00 0.00
June 4207.41 12-JUN-05:03 425.28 128.87 1947.18 0.00 0.00 0.00 0.00 0.00 0.00
July 4049.99 19-JUL-05:02 531.60 161.09 2433.97 0.00 0.00 0.00 0.00 0.00 0.00
August 4004.82 14-AUG-05:01 744.23 225.53 3407.56 0.00 0.00 0.00 0.00 0.00 0.00
September 4046.27 11-SEP-05:02 637.92 193.31 2920.76 0.00 0.00 0.00 0.00 0.00 0.00
October 4193.21 05-OCT-05:03 318.96 96.65 1460.38 0.00 0.00 0.00 0.00 0.00 0.00
November 1274.58 08-NOV-16:05 1933.08 1487.88 1947.18 0.00 0.00 0.00 0.00 0.00 0.00
December 1310.76 06-DEC-16:57 2899.62 2231.82 2920.76 0.00 0.00 0.00 0.00 0.00 0.00
                       
Annual Sum or Average           0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 1217.37   318.96 96.65 973.59 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4207.41   2899.62 2231.82 3407.56 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 781.48 06-JAN-10:23 2198.10 1234.89 2214.13 0.00 0.00 0.00 0.00 0.00 302.22
February 1187.42 27-FEB-15:20 1465.40 823.26 1476.09 0.00 0.00 0.00 0.00 0.00 57.35
March 1839.22 01-MAR-13:10 1465.40 823.26 1476.09 0.00 0.00 0.00 0.00 0.00 190.60
April 3118.21 27-APR-14:30 732.70 411.63 738.04 0.00 0.00 0.00 0.00 39.27 0.00
May 2518.62 15-MAY-14:00 732.70 411.63 738.04 0.00 0.00 0.00 0.00 0.00 8.84
June 2549.15 28-JUN-14:00 732.70 411.63 738.04 0.00 0.00 0.00 0.00 16.17 0.00
July 6015.51 24-JUL-05:01 564.18 170.96 2583.15 0.00 0.00 0.00 0.00 0.00 121.23
August 5859.42 09-AUG-05:02 402.98 122.12 1845.11 0.00 0.00 0.00 0.00 0.00 169.45
September 5994.36 11-SEP-05:02 483.58 146.54 2214.13 0.00 0.00 0.00 0.00 0.00 250.66
October 4527.86 04-OCT-13:50 732.70 411.63 738.04 0.00 0.00 0.00 0.00 0.00 43.20
November 1153.78 15-NOV-13:30 732.70 411.63 738.04 0.00 0.00 0.00 0.00 0.00 208.88
December 1055.86 05-DEC-14:30 732.70 411.63 738.04 0.00 0.00 0.00 0.00 0.00 192.17
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 781.48   402.98 122.12 738.04 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 6015.51   2198.10 1234.89 2583.15 0.00 0.00 0.00 0.00 39.27 302.22



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 410.27 06-JAN-11:07 1303.94 732.55 1313.45 0.00 0.00 0.00 0.00 0.00 26.32
February 362.63 10-FEB-08:55 869.29 488.37 875.63 0.00 0.00 0.00 0.00 0.00 27.62
March 404.16 02-MAR-08:07 1738.59 976.74 1751.27 0.00 0.00 0.00 0.00 0.00 26.50
April 2929.47 28-APR-12:02 2607.88 1465.11 2626.90 0.00 0.00 0.00 0.00 0.00 12.28
May 3362.02 15-MAY-10:02 2173.23 1220.92 2189.08 0.00 0.00 0.00 0.00 0.00 7.64
June 3320.67 28-JUN-10:02 1738.59 976.74 1751.27 0.00 0.00 0.00 0.00 0.00 3.68
July 3520.13 24-JUL-05:01 334.68 101.42 1532.36 0.00 0.00 0.00 0.00 0.00 8.55
August 3495.28 14-AUG-09:04 0.00 1220.92 2189.08 0.00 0.00 0.00 0.00 0.00 10.66
September 3522.10 11-SEP-10:02 1738.59 976.74 1751.27 0.00 0.00 0.00 0.00 0.00 5.05
October 2636.45 04-OCT-10:02 1738.59 976.74 1751.27 0.00 0.00 0.00 0.00 0.00 11.56
November 392.55 13-NOV-11:07 1303.94 732.55 1313.45 0.00 0.00 0.00 0.00 0.00 16.89
December 344.03 12-DEC-11:05 1738.59 985.22 1751.27 0.00 0.00 0.00 0.00 0.00 2.23
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 344.03   0.00 101.42 875.63 0.00 0.00 0.00 0.00 0.00 2.23
Maximum of Months 3522.10   2607.88 1465.11 2626.90 0.00 0.00 0.00 0.00 0.00 27.62



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 336.14 27-JAN-14:00 732.70 508.23 738.04 0.00 0.00 0.00 0.00 0.00 35.97
February 460.97 03-FEB-15:53 2198.10 1589.42 2214.13 0.00 0.00 0.00 0.00 0.00 25.82
March 615.70 22-MAR-11:43 1341.71 1254.97 2081.28 0.00 0.00 0.00 0.00 0.00 66.39
April 1057.36 27-APR-15:53 2930.79 1676.65 2952.17 0.00 0.00 0.00 0.00 10.26 0.00
May 1384.67 05-MAY-15:30 1465.40 823.26 1476.09 0.00 0.00 0.00 0.00 1.76 0.00
June 1870.71 28-JUN-15:53 2198.10 1252.64 2214.13 0.00 0.00 0.00 0.00 7.75 0.00
July 3677.15 24-JUL-05:01 564.18 170.96 2583.15 0.00 0.00 0.00 0.00 0.00 12.04
August 3488.98 09-AUG-05:02 402.98 122.12 1845.11 0.00 0.00 0.00 0.00 0.00 51.34
September 1837.57 14-SEP-15:47 2198.10 1378.08 2214.13 0.00 0.00 0.00 0.00 0.85 0.00
October 1082.37 04-OCT-15:57 2198.10 1538.68 2214.13 0.00 0.00 0.00 0.00 0.00 11.16
November 661.96 30-NOV-13:55 1465.40 1057.77 1476.09 0.00 0.00 0.00 0.00 0.00 69.92
December 703.40 21-DEC-16:53 2198.10 1691.87 2214.13 0.00 0.00 0.00 0.00 0.00 36.87
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 336.14   402.98 122.12 738.04 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3677.15   2930.79 1691.87 2952.17 0.00 0.00 0.00 0.00 10.26 69.92



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE LIGHTS TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY {AT MAX/MIN} [W] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 281.74 05-JAN-16:53 1303.94 1003.64 1313.45 0.00 0.00 0.00 0.00 0.00 29.36
February 274.31 09-FEB-16:43 1303.94 840.23 1313.45 0.00 0.00 0.00 0.00 0.00 34.79
March 466.93 02-MAR-16:35 1738.59 976.74 1751.27 0.00 0.00 0.00 0.00 0.00 8.69
April 1640.48 27-APR-15:55 1738.59 976.74 1751.27 0.00 0.00 0.00 0.00 6.84 0.00
May 2007.14 15-MAY-15:57 1303.94 732.55 1313.45 0.00 0.00 0.00 0.00 0.01 0.00
June 2564.69 23-JUN-05:02 239.06 72.44 1094.54 0.00 0.00 0.00 0.00 0.00 107.95
July 4195.18 24-JUL-05:01 334.68 101.42 1532.36 0.00 0.00 0.00 0.00 0.00 8.83
August 4086.99 15-AUG-05:02 239.06 72.44 1094.54 0.00 0.00 0.00 0.00 0.00 41.71
September 4095.18 11-SEP-05:02 286.87 86.93 1313.45 0.00 0.00 0.00 0.00 0.00 53.22
October 1854.56 04-OCT-15:57 1303.94 732.55 1313.45 0.00 0.00 0.00 0.00 0.00 7.44
November 259.85 09-NOV-08:15 869.29 652.16 875.63 0.00 0.00 0.00 0.00 0.00 24.57
December 377.38 06-DEC-17:00 1303.94 1003.64 1313.45 0.00 0.00 0.00 0.00 0.00 28.46
                       
Annual Sum or Average           0.00 0.00 0.00 0.00    
Minimum of Months 259.85   239.06 72.44 875.63 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 4195.18   1738.59 1003.64 1751.27 0.00 0.00 0.00 0.00 6.84 107.95



Table of Contents

Report: SpaceGainComponentsAtCoolingPeakMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE AIR SYSTEM SENSIBLE COOLING RATE {Maximum} [W] ZONE AIR SYSTEM SENSIBLE COOLING RATE {TIMESTAMP} ZONE PEOPLE TOTAL HEATING ENERGY [] ZONE LIGHTS TOTAL HEATING ENERGY [] ZONE ELECTRIC EQUIPMENT TOTAL HEATING ENERGY [] ZONE GAS EQUIPMENT TOTAL HEATING ENERGY [] ZONE HOT WATER EQUIPMENT TOTAL HEATING ENERGY [] ZONE STEAM EQUIPMENT TOTAL HEATING ENERGY [] ZONE OTHER EQUIPMENT TOTAL HEATING ENERGY [] ZONE INFILTRATION SENSIBLE HEAT GAIN ENERGY {AT MAX/MIN} [W] ZONE INFILTRATION SENSIBLE HEAT LOSS ENERGY {AT MAX/MIN} [W]
January 0.00 01-JAN-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 404.94 0.00
February 0.00 01-FEB-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 459.41 0.00
March 0.00 01-MAR-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 819.77 0.00
April 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 244.73 0.00
May 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 582.72 0.00
June 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 870.10 0.00
July 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 425.37 0.00
August 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 733.12 0.00
September 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 659.26 0.00
October 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1110.69 0.00
November 0.00 01-NOV-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 417.10 0.00
December 0.00 01-DEC-00:10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 925.44 0.00
                       
Annual Sum or Average     0.00 0.00 0.00 0.00 0.00 0.00 0.00    
Minimum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 244.73 0.00
Maximum of Months 0.00   0.00 0.00 0.00 0.00 0.00 0.00 0.00 1110.69 0.00



Table of Contents

Report: EnergyConsumptionElectricityNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ELECTRICITY:FACILITY [J] ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} NATURALGAS:FACILITY [J] NATURALGAS:FACILITY {Maximum} [W] NATURALGAS:FACILITY {TIMESTAMP}
January 0.138037E+11 15806.62 17-JAN-08:09 0.256796E+09 18238.88 17-JAN-06:19
February 0.116652E+11 17172.11 21-FEB-08:20 0.197761E+09 12803.31 21-FEB-07:10
March 0.120906E+11 12089.50 06-MAR-08:30 26264798.73 4489.02 27-MAR-05:10
April 0.105558E+11 12555.96 27-APR-15:39 10191200.30 3936.82 18-APR-05:10
May 0.112684E+11 12252.65 05-MAY-14:20 0.00 0.00 01-MAY-00:10
June 0.115374E+11 12846.31 28-JUN-15:50 0.00 0.00 01-JUN-00:10
July 0.116413E+11 14102.54 31-JUL-15:39 0.00 0.00 01-JUL-00:10
August 0.132642E+11 14324.81 10-AUG-15:30 0.00 0.00 01-AUG-00:10
September 0.113713E+11 13350.45 14-SEP-15:30 0.00 0.00 01-SEP-00:10
October 0.112936E+11 12250.23 04-OCT-15:30 0.00 0.00 01-OCT-00:10
November 0.117494E+11 14527.71 13-NOV-07:10 26393960.21 5491.41 24-NOV-06:10
December 0.127680E+11 17721.59 26-DEC-08:09 0.225069E+09 19354.17 26-DEC-06:19
             
Annual Sum or Average 0.143009E+12     0.742476E+09    
Minimum of Months 0.105558E+11 12089.50   0.00 0.00  
Maximum of Months 0.138037E+11 17721.59   0.256796E+09 19354.17  



Table of Contents

Report: EndUseEnergyConsumptionElectricityMonthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY [J] EXTERIORLIGHTS:ELECTRICITY [J] INTERIOREQUIPMENT:ELECTRICITY [J] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY [J] PUMPS:ELECTRICITY [J] HEATING:ELECTRICITY [J] COOLING:ELECTRICITY [J] HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY [J] COGENERATION:ELECTRICITY []
January 0.233936E+10 0.120973E+10 0.405300E+10 0.00 0.156418E+10 0.02 0.249955E+10 0.00 0.00 0.00 0.00 0.213785E+10 0.00
February 0.206415E+10 0.949992E+09 0.366466E+10 0.00 0.139781E+10 0.01 0.165150E+10 4416435.41 0.00 0.00 0.00 0.193263E+10 0.00
March 0.241586E+10 0.861761E+09 0.429420E+10 0.00 0.167065E+10 0.00 0.650236E+09 21830675.46 0.00 0.00 0.00 0.217605E+10 0.00
April 0.208064E+10 0.665175E+09 0.388642E+10 0.00 0.145353E+10 0.00 0.247138E+09 0.184988E+09 0.00 0.00 0.00 0.203788E+10 0.00
May 0.223360E+10 0.568556E+09 0.417360E+10 0.00 0.160119E+10 0.00 13727314.25 0.562177E+09 0.00 0.00 0.00 0.211551E+10 0.00
June 0.221600E+10 0.497288E+09 0.412149E+10 0.00 0.160802E+10 0.00 243723.59 0.105365E+10 0.00 0.00 0.00 0.204069E+10 0.00
July 0.206661E+10 0.535596E+09 0.393546E+10 0.00 0.146709E+10 0.00 0.00 0.159569E+10 0.00 0.00 0.00 0.204084E+10 0.00
August 0.235239E+10 0.627856E+09 0.429420E+10 0.00 0.169072E+10 0.00 0.00 0.220322E+10 0.00 0.00 0.00 0.209576E+10 0.00
September 0.210923E+10 0.753744E+09 0.388029E+10 0.00 0.146181E+10 0.00 485003.11 0.117514E+10 0.00 0.00 0.00 0.199056E+10 0.00
October 0.226699E+10 0.970854E+09 0.405607E+10 0.00 0.152688E+10 0.00 43145765.22 0.349237E+09 0.00 0.00 0.00 0.208047E+10 0.00
November 0.232104E+10 0.111763E+10 0.400396E+10 0.00 0.152554E+10 0.00 0.707509E+09 23209669.29 0.00 0.00 0.00 0.205050E+10 0.00
December 0.225718E+10 0.125623E+10 0.393240E+10 0.00 0.146148E+10 0.00 0.175761E+10 1279713.69 0.00 0.00 0.00 0.210178E+10 0.00
                           
Annual Sum or Average 0.267231E+11 0.100144E+11 0.482958E+11 0.00 0.184289E+11 0.03 0.757115E+10 0.717484E+10 0.00 0.00 0.00 0.248005E+11 0.00
Minimum of Months 0.206415E+10 0.497288E+09 0.366466E+10 0.00 0.139781E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.193263E+10 0.00
Maximum of Months 0.241586E+10 0.125623E+10 0.429420E+10 0.00 0.169072E+10 0.02 0.249955E+10 0.220322E+10 0.00 0.00 0.00 0.217605E+10 0.00



Table of Contents

Report: EndUseEnergyConsumptionNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS [J] COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [] COGENERATION:NATURALGAS [] HUMIDIFIER:NATURALGAS []
January 0.00 0.00 0.256796E+09 0.00 0.00 0.00 0.00
February 0.00 0.00 0.197761E+09 0.00 0.00 0.00 0.00
March 0.00 0.00 26264798.73 0.00 0.00 0.00 0.00
April 0.00 0.00 10191200.30 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 26393960.21 0.00 0.00 0.00 0.00
December 0.00 0.00 0.225069E+09 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.742476E+09 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.256796E+09 0.00 0.00 0.00 0.00



Table of Contents

Report: PeakEnergyEndUseElectricityPart1Monthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

INTERIORLIGHTS:ELECTRICITY {Maximum} [W] INTERIORLIGHTS:ELECTRICITY {TIMESTAMP} EXTERIORLIGHTS:ELECTRICITY {Maximum} [W] EXTERIORLIGHTS:ELECTRICITY {TIMESTAMP} INTERIOREQUIPMENT:ELECTRICITY {Maximum} [W] INTERIOREQUIPMENT:ELECTRICITY {TIMESTAMP} EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {Maximum} [W] FANS:ELECTRICITY {TIMESTAMP} PUMPS:ELECTRICITY {Maximum} [W] PUMPS:ELECTRICITY {TIMESTAMP} HEATING:ELECTRICITY {Maximum} [W] HEATING:ELECTRICITY {TIMESTAMP}
January 2540.94 02-JAN-16:30 1061.67 01-JAN-06:10 3325.31 02-JAN-08:09 0.00 1612.68 02-JAN-06:10 0.00 02-JAN-07:10 7263.07 09-JAN-07:00
February 2513.41 02-FEB-16:00 1061.67 01-FEB-06:10 3325.31 01-FEB-08:09 0.00 1612.68 06-FEB-06:10 0.00 01-FEB-07:10 7636.87 21-FEB-07:00
March 2488.23 22-MAR-07:10 1061.67 01-MAR-06:10 3325.31 01-MAR-08:09 0.00 1612.68 01-MAR-09:30 0.00 01-MAR-00:10 5157.14 06-MAR-06:19
April 2445.38 03-APR-07:10 1061.67 01-APR-05:10 3325.31 03-APR-07:10 0.00 1612.68 03-APR-05:10 0.00 01-APR-00:10 3338.71 18-APR-06:19
May 2372.26 17-MAY-07:10 675.04 01-MAY-19:19 3325.31 01-MAY-07:10 0.00 1612.68 01-MAY-12:20 0.00 01-MAY-00:10 790.11 18-MAY-06:30
June 2348.77 16-JUN-07:10 675.04 01-JUN-19:00 3325.31 01-JUN-07:10 0.00 1612.68 01-JUN-06:40 0.00 01-JUN-00:10 51.01 15-JUN-06:40
July 2427.30 12-JUL-08:30 675.04 01-JUL-20:10 3325.31 03-JUL-07:10 0.00 1612.68 03-JUL-12:50 0.00 01-JUL-00:10 0.00 01-JUL-00:10
August 2427.18 02-AUG-07:30 1061.67 16-AUG-05:10 3325.31 01-AUG-07:10 0.00 1612.68 01-AUG-05:10 0.00 01-AUG-00:10 0.00 01-AUG-00:10
September 2490.17 25-SEP-07:10 1061.67 01-SEP-05:10 3325.31 01-SEP-07:10 0.00 1612.68 01-SEP-05:10 0.00 01-SEP-00:10 231.97 28-SEP-06:30
October 2537.40 31-OCT-07:10 1061.67 01-OCT-05:10 3325.31 02-OCT-07:10 0.00 1612.68 04-OCT-07:00 0.00 01-OCT-00:10 1482.73 30-OCT-06:19
November 2540.94 06-NOV-16:49 1061.67 01-NOV-05:10 3325.31 01-NOV-07:10 0.00 1612.68 13-NOV-06:10 0.00 01-NOV-00:10 6719.33 24-NOV-07:10
December 2540.94 01-DEC-16:19 1061.67 01-DEC-06:10 3325.31 01-DEC-08:09 0.00 1612.68 04-DEC-06:10 0.00 01-DEC-00:10 7581.69 26-DEC-06:19
                           
Annual Sum or Average             0.00            
Minimum of Months 2348.77   675.04   3325.31   0.00 1612.68   0.00   0.00  
Maximum of Months 2540.94   1061.67   3325.31   0.00 1612.68   0.00   7636.87  



Table of Contents

Report: PeakEnergyEndUseElectricityPart2Monthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

COOLING:ELECTRICITY {Maximum} [W] COOLING:ELECTRICITY {TIMESTAMP} HEATREJECTION:ELECTRICITY [] HUMIDIFIER:ELECTRICITY [] HEATRECOVERY:ELECTRICITY [] WATERSYSTEMS:ELECTRICITY {Maximum} [W] WATERSYSTEMS:ELECTRICITY {TIMESTAMP} COGENERATION:ELECTRICITY []
January 0.00 01-JAN-00:10 0.00 0.00 0.00 2812.90 31-JAN-12:20 0.00
February 312.46 27-FEB-14:00 0.00 0.00 0.00 2813.06 17-FEB-12:50 0.00
March 436.64 02-MAR-15:00 0.00 0.00 0.00 2812.01 06-MAR-12:09 0.00
April 2770.67 27-APR-15:09 0.00 0.00 0.00 2808.32 03-APR-11:30 0.00
May 2457.74 05-MAY-15:50 0.00 0.00 0.00 2802.94 01-MAY-11:30 0.00
June 3076.13 28-JUN-15:00 0.00 0.00 0.00 2796.57 01-JUN-11:50 0.00
July 4350.30 24-JUL-14:00 0.00 0.00 0.00 2790.99 05-JUL-11:20 0.00
August 4488.12 10-AUG-15:00 0.00 0.00 0.00 2789.16 31-AUG-11:50 0.00
September 3525.06 14-SEP-14:30 0.00 0.00 0.00 2792.18 28-SEP-11:00 0.00
October 2371.82 04-OCT-14:00 0.00 0.00 0.00 2798.10 30-OCT-11:39 0.00
November 430.94 02-NOV-13:39 0.00 0.00 0.00 2804.50 30-NOV-12:50 0.00
December 160.17 05-DEC-14:30 0.00 0.00 0.00 2809.56 29-DEC-12:20 0.00
                 
Annual Sum or Average     0.00 0.00 0.00     0.00
Minimum of Months 0.00   0.00 0.00 0.00 2789.16   0.00
Maximum of Months 4488.12   0.00 0.00 0.00 2813.06   0.00



Table of Contents

Report: ElectricComponentsOfPeakDemandMonthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ELECTRICITY:FACILITY {Maximum} [W] ELECTRICITY:FACILITY {TIMESTAMP} INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] EXTERIOREQUIPMENT:ELECTRICITY [] FANS:ELECTRICITY {AT MAX/MIN} [W] PUMPS:ELECTRICITY {AT MAX/MIN} [W] HEATING:ELECTRICITY {AT MAX/MIN} [W] COOLING:ELECTRICITY {AT MAX/MIN} [W] HEATREJECTION:ELECTRICITY []
January 15806.62 17-JAN-08:09 2503.18 3325.31 0.00 0.00 1612.68 0.00 5626.03 0.00 0.00
February 17172.11 21-FEB-08:20 2264.81 3325.31 0.00 0.00 1612.68 0.00 7229.19 0.00 0.00
March 12089.50 06-MAR-08:30 2199.11 3325.31 0.00 0.00 1612.68 0.00 2212.65 0.00 0.00
April 12555.96 27-APR-15:39 2097.67 3325.31 0.00 0.00 1612.68 0.00 0.00 2758.25 0.00
May 12252.65 05-MAY-14:20 2189.39 3325.31 0.00 0.00 1612.68 0.00 0.00 2391.42 0.00
June 12846.31 28-JUN-15:50 2094.00 3325.31 0.00 0.00 1612.68 0.00 0.00 3060.58 0.00
July 14102.54 31-JUL-15:39 2213.46 3325.31 0.00 0.00 1612.68 0.00 0.00 4199.56 0.00
August 14324.81 10-AUG-15:30 2181.05 3325.31 0.00 0.00 1612.68 0.00 0.00 4454.45 0.00
September 13350.45 14-SEP-15:30 2144.08 3325.31 0.00 0.00 1612.68 0.00 0.00 3515.75 0.00
October 12250.23 04-OCT-15:30 2209.36 3325.31 0.00 0.00 1612.68 0.00 0.00 2348.54 0.00
November 14527.71 13-NOV-07:10 1185.75 1662.65 1061.67 0.00 1612.68 0.00 6310.72 0.00 0.00
December 17721.59 26-DEC-08:09 2528.01 3325.31 0.00 0.00 1612.68 0.00 7517.36 0.00 0.00
                       
Annual Sum or Average           0.00         0.00
Minimum of Months 12089.50   1185.75 1662.65 0.00 0.00 1612.68 0.00 0.00 0.00 0.00
Maximum of Months 17721.59   2528.01 3325.31 1061.67 0.00 1612.68 0.00 7517.36 4454.45 0.00



Table of Contents

Report: PeakEnergyEndUseNaturalGasMonthly

For: Meter

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

INTERIOREQUIPMENT:NATURALGAS [] EXTERIOREQUIPMENT:NATURALGAS [] HEATING:NATURALGAS {Maximum} [W] HEATING:NATURALGAS {TIMESTAMP} COOLING:NATURALGAS [] WATERSYSTEMS:NATURALGAS [] COGENERATION:NATURALGAS []
January 0.00 0.00 18238.88 17-JAN-06:19 0.00 0.00 0.00
February 0.00 0.00 12803.31 21-FEB-07:10 0.00 0.00 0.00
March 0.00 0.00 4489.02 27-MAR-05:10 0.00 0.00 0.00
April 0.00 0.00 3936.82 18-APR-05:10 0.00 0.00 0.00
May 0.00 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00
June 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00
August 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00
September 0.00 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00
October 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00
November 0.00 0.00 5491.41 24-NOV-06:10 0.00 0.00 0.00
December 0.00 0.00 19354.17 26-DEC-06:19 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00     0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00   0.00 0.00 0.00
Maximum of Months 0.00 0.00 19354.17   0.00 0.00 0.00



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 2.67 19.68 2.67 19.68 0.00 19.68 0.00 19.68
February 0.17 20.12 0.17 20.12 0.00 20.12 0.00 20.12
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.67 24.67 0.67 24.67
August 0.00 0.00 0.00 0.00 1.83 24.65 1.83 24.65
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.17 19.96 0.17 19.96 0.00 19.96 0.00 19.96
                 
Annual Sum or Average 3.00 19.72 3.00 19.72 2.50 21.17 2.50 21.96
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 2.67 20.12 2.67 20.12 1.83 24.67 1.83 24.67



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 2.67 19.69 2.50 19.84 0.00 19.84 0.00 19.84
February 0.50 20.20 0.50 20.20 0.00 20.20 0.00 20.20
March 0.33 20.35 0.33 20.35 0.00 20.35 0.00 20.35
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.17 20.51 0.17 20.51 0.00 20.51 0.00 20.51
December 1.00 20.12 1.00 20.12 0.00 20.12 0.00 20.12
                 
Annual Sum or Average 4.67 19.91 4.50 20.00 0.00 20.00 0.00 20.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 2.67 20.51 2.50 20.51 0.00 20.51 0.00 20.51



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 5.17 18.55 3.67 19.16 0.00 19.16 0.00 19.16
February 1.83 18.76 1.33 19.36 0.00 19.36 0.00 19.36
March 0.33 20.07 0.33 20.07 0.00 20.07 0.00 20.07
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.17 20.32 0.17 20.32 0.00 20.32 0.00 20.32
December 1.83 18.71 1.33 19.30 0.00 19.30 0.00 19.30
                 
Annual Sum or Average 9.33 18.70 6.83 19.29 0.00 19.29 0.00 19.29
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 5.17 20.32 3.67 20.32 0.00 20.32 0.00 20.32



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 11.17 19.13 9.83 19.40 0.00 19.40 0.00 19.40
February 5.00 19.11 4.17 19.49 0.00 19.49 0.00 19.49
March 1.33 19.91 1.33 19.91 0.00 19.91 0.00 19.91
April 0.17 20.31 0.17 20.31 0.00 20.31 0.00 20.31
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 1.50 20.33 1.50 20.33 0.00 20.33 0.00 20.33
December 4.33 19.58 4.00 19.76 0.00 19.76 0.00 19.76
                 
Annual Sum or Average 23.50 19.34 21.00 19.58 0.00 19.58 0.00 19.58
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 11.17 20.33 9.83 20.33 0.00 20.33 0.00 20.33



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 3.83 18.31 2.50 19.01 0.00 19.01 0.00 19.01
February 1.67 18.13 1.00 18.92 0.00 18.92 0.00 18.92
March 0.33 20.23 0.33 20.23 0.00 20.23 0.00 20.23
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.17 20.50 0.17 20.50 0.00 20.50 0.00 20.50
December 1.33 18.16 0.83 18.90 0.00 18.90 0.00 18.90
                 
Annual Sum or Average 7.33 18.38 4.83 19.08 0.00 19.08 0.00 19.08
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 3.83 20.50 2.50 20.50 0.00 20.50 0.00 20.50



Table of Contents

Report: SetpointsNotMetWithTemperaturesMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE HEATING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE HEATING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE COOLING SETPOINT NOT MET WHILE OCCUPIED TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.00   0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: ComfortReportSimple55Monthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 21.13 94.00 21.04 94.00 20.98
February 323.00 21.53 38.50 21.45 38.50 21.39
March 391.00 22.46 0.00 22.46 0.00 22.46
April 307.00 23.08 8.67 23.13 0.00 23.13
May 159.33 23.80 37.50 24.00 0.00 24.00
June 39.67 23.85 108.33 24.63 0.00 24.63
July 2.17 23.89 208.67 24.69 0.00 24.69
August 0.00 0.00 302.00 24.56 0.00 24.56
September 16.00 23.83 142.17 24.56 0.00 24.56
October 271.50 23.57 11.00 23.62 0.00 23.62
November 357.00 22.36 3.50 22.36 3.50 22.36
December 340.00 21.39 34.17 21.33 34.17 21.28
             
Annual Sum or Average 2563.67 22.31 988.50 22.78 170.17 22.69
Minimum of Months 0.00 0.00 0.00 21.04 0.00 20.98
Maximum of Months 391.00 23.89 302.00 24.69 94.00 24.69



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 20.69 304.83 20.63 304.83 20.60
February 323.00 21.22 177.83 21.00 177.83 20.89
March 391.00 21.78 106.50 21.58 106.50 21.45
April 311.00 22.28 52.83 22.17 43.17 22.03
May 314.83 23.14 7.00 23.18 0.00 23.18
June 231.50 23.52 27.00 23.70 0.00 23.70
July 77.17 23.69 133.83 24.40 0.00 24.40
August 38.33 23.62 217.83 24.56 0.00 24.56
September 117.00 23.49 119.83 24.10 0.00 24.10
October 269.00 22.81 22.83 22.94 0.17 22.93
November 357.00 21.57 125.00 21.33 125.00 21.18
December 340.00 20.94 235.50 20.80 235.50 20.74
             
Annual Sum or Average 3126.83 22.02 1530.83 22.04 993.00 21.79
Minimum of Months 38.33 20.69 7.00 20.63 0.00 20.60
Maximum of Months 391.00 23.69 304.83 24.56 304.83 24.56



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 294.00 20.41 285.00 20.39 285.00 20.39
February 266.00 20.61 219.83 20.52 219.83 20.49
March 322.00 21.16 168.50 20.97 168.50 20.88
April 266.67 22.13 54.00 21.90 52.00 21.73
May 270.67 23.18 4.83 23.22 0.00 23.22
June 154.50 23.65 38.50 23.94 0.00 23.94
July 56.67 23.87 109.50 24.55 0.00 24.55
August 32.67 23.86 167.67 24.63 0.00 24.63
September 152.50 23.64 63.00 23.93 0.00 23.93
October 284.33 22.65 12.50 22.57 12.50 22.49
November 294.00 21.17 154.50 20.95 154.50 20.84
December 280.00 20.51 261.83 20.48 261.83 20.48
             
Annual Sum or Average 2674.00 21.79 1539.67 21.71 1154.17 21.44
Minimum of Months 32.67 20.41 4.83 20.39 0.00 20.39
Maximum of Months 322.00 23.87 285.00 24.63 285.00 24.63



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 20.52 340.33 20.50 340.33 20.50
February 323.00 20.66 263.00 20.60 263.00 20.57
March 391.00 20.97 247.17 20.86 247.17 20.81
April 339.00 21.70 97.33 21.49 97.33 21.35
May 363.83 23.08 0.50 23.08 0.00 23.08
June 266.50 23.62 21.00 23.73 0.00 23.73
July 105.83 23.84 78.83 24.35 0.00 24.35
August 72.17 23.82 109.50 24.46 0.00 24.46
September 238.67 23.58 21.17 23.68 0.00 23.68
October 357.00 22.37 16.50 22.29 16.50 22.22
November 357.00 21.14 191.17 20.96 191.17 20.88
December 340.00 20.61 316.00 20.59 316.00 20.59
             
Annual Sum or Average 3511.00 21.83 1702.50 21.62 1471.50 21.39
Minimum of Months 72.17 20.52 0.50 20.50 0.00 20.50
Maximum of Months 391.00 23.84 340.33 24.46 340.33 24.46



Table of Contents

Report: ComfortReportSimple55Monthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 357.00 20.57 333.33 20.54 333.33 20.53
February 323.00 20.84 233.33 20.71 233.33 20.66
March 391.00 21.38 181.83 21.18 181.83 21.08
April 316.17 22.17 70.67 22.04 61.33 21.87
May 296.50 23.36 31.17 23.55 0.00 23.55
June 202.67 23.80 69.17 24.27 4.83 24.33
July 80.83 25.02 153.50 25.35 23.00 25.58
August 70.00 25.34 188.33 25.28 24.17 25.52
September 148.33 23.72 84.50 24.24 0.00 24.24
October 333.33 22.81 11.83 22.78 9.17 22.72
November 357.00 21.36 175.17 21.12 175.17 21.00
December 340.00 20.67 300.17 20.63 300.17 20.61
             
Annual Sum or Average 3215.83 22.00 1833.00 22.00 1346.33 21.77
Minimum of Months 70.00 20.57 11.83 20.54 0.00 20.53
Maximum of Months 391.00 25.34 333.33 25.35 333.33 25.58



Table of Contents

Report: ComfortReportSimple55Monthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C] ZONE THERMAL COMFORT ASHRAE 55 SIMPLE MODEL SUMMER OR WINTER CLOTHES NOT COMFORTABLE TIME {HOURS NON-ZERO} [HOURS] ZONE MEAN AIR TEMPERATURE {FOR HOURS SHOWN} [C]
January 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00
             
Annual Sum or Average 0.00   0.00   0.00  
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 294.00000 0.00000 0.00000 0.00000 0.00000
February 266.00000 0.00000 0.00000 0.00000 0.00000
March 322.00000 0.00000 0.00000 0.00000 0.00000
April 280.00000 0.00000 0.00000 0.00000 0.00000
May 308.00000 0.00000 0.00000 0.00000 0.00000
June 308.00000 0.00000 0.00000 0.00000 0.00000
July 280.00000 0.00000 0.00000 0.00000 0.00000
August 322.00000 0.00000 0.00000 0.00000 0.00000
September 280.00000 0.00000 0.00000 0.00000 0.00000
October 294.00000 0.00000 0.00000 0.00000 0.00000
November 294.00000 0.00000 0.00000 0.00000 0.00000
December 280.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 3528.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 266.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 322.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: OccupantComfortDataSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PEOPLE OCCUPANT COUNT {HOURS NON-ZERO} [HOURS] PEOPLE AIR TEMPERATURE {FOR HOURS SHOWN} [C] PEOPLE AIR RELATIVE HUMIDITY {FOR HOURS SHOWN} [%] ZONE THERMAL COMFORT FANGER MODEL PMV [] ZONE THERMAL COMFORT FANGER MODEL PPD []
January 357.00000 0.00000 0.00000 0.00000 0.00000
February 323.00000 0.00000 0.00000 0.00000 0.00000
March 391.00000 0.00000 0.00000 0.00000 0.00000
April 340.00000 0.00000 0.00000 0.00000 0.00000
May 374.00000 0.00000 0.00000 0.00000 0.00000
June 374.00000 0.00000 0.00000 0.00000 0.00000
July 340.00000 0.00000 0.00000 0.00000 0.00000
August 391.00000 0.00000 0.00000 0.00000 0.00000
September 340.00000 0.00000 0.00000 0.00000 0.00000
October 357.00000 0.00000 0.00000 0.00000 0.00000
November 357.00000 0.00000 0.00000 0.00000 0.00000
December 340.00000 0.00000 0.00000 0.00000 0.00000
           
Annual Sum or Average 4284.00000 0.00000 0.00000 0.00000 0.00000
Minimum of Months 323.00000 0.00000 0.00000 0.00000 0.00000
Maximum of Months 391.00000 0.00000 0.00000 0.00000 0.00000



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:1 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00
March 9985309.73 2271247.49 8.42 7974685.19 2010624.55 0.00 0.13 10-MAR-15:23 0.00 01-MAR-00:10 553.08 10-MAR-15:23 421.43 10-MAR-16:00 138.09 10-MAR-14:25 125.05 10-MAR-15:23 0.00
April 0.282498E+09 62975755.89 82.29 0.240022E+09 42476160.00 0.00 1.00 28-APR-05:03 0.00 01-APR-00:10 5011.42 28-APR-05:03 4018.25 28-APR-05:03 993.17 28-APR-05:03 976.60 28-APR-05:03 0.00
May 0.108819E+10 0.238400E+09 235.97 0.903296E+09 0.184896E+09 0.00 1.00 05-MAY-05:03 0.00 01-MAY-00:10 5082.36 08-MAY-05:03 4608.74 16-MAY-05:03 1283.77 08-MAY-05:03 985.58 08-MAY-05:03 0.00
June 0.174692E+10 0.376022E+09 255.25 0.147428E+10 0.272641E+09 0.00 1.00 09-JUN-05:03 0.00 01-JUN-00:10 5103.43 13-JUN-05:03 4708.88 12-JUN-05:03 1364.91 13-JUN-05:03 988.01 13-JUN-05:03 0.00
July 0.230192E+10 0.488361E+09 239.72 0.190920E+10 0.392717E+09 0.00 1.00 03-JUL-05:03 0.00 01-JUL-00:10 5125.59 28-JUL-05:02 4507.72 19-JUL-05:02 1324.45 28-JUL-05:15 1034.42 24-JUL-15:00 0.00
August 0.298184E+10 0.634938E+09 275.87 0.242950E+10 0.552337E+09 0.00 1.00 01-AUG-05:02 0.00 01-AUG-00:10 5114.43 10-AUG-05:02 4420.50 14-AUG-05:01 1292.43 28-AUG-05:15 1019.68 10-AUG-16:00 0.00
September 0.175550E+10 0.373979E+09 233.62 0.140349E+10 0.352005E+09 0.00 1.00 01-SEP-05:02 0.00 01-SEP-00:10 5105.13 26-SEP-05:03 4480.74 11-SEP-05:02 1402.33 26-SEP-05:03 988.20 26-SEP-05:03 0.00
October 0.590062E+09 0.130088E+09 164.24 0.503409E+09 86652300.61 0.00 1.00 05-OCT-05:03 0.00 01-OCT-00:10 4969.16 06-OCT-05:03 4750.10 05-OCT-05:03 744.67 06-OCT-05:03 970.66 06-OCT-05:03 0.00
November 81960912.47 18498636.06 48.33 59854788.55 22106123.92 0.00 0.24 03-NOV-16:00 0.00 01-NOV-00:10 1033.25 03-NOV-16:00 689.63 03-NOV-16:00 343.62 03-NOV-16:00 229.31 03-NOV-16:00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00
                                       
Annual Sum or Average 0.108389E+11 0.232553E+10 1543.70 0.893104E+10 0.190784E+10 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.298184E+10 0.634938E+09 275.87 0.242950E+10 0.552337E+09 0.00 1.00   0.00   5125.59   4750.10   1402.33   1034.42   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:2 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00
February 19540433.83 4398812.08 9.33 19500559.35 39874.48 0.00 0.24 27-FEB-15:00 0.00 01-FEB-00:10 1402.50 27-FEB-15:00 1402.50 27-FEB-15:00 12.25 27-FEB-17:00 312.46 27-FEB-15:00 0.00
March 83127012.42 18659916.52 34.92 82873921.40 253091.02 0.00 0.27 02-MAR-14:25 0.00 01-MAR-00:10 1568.16 02-MAR-14:25 1568.16 02-MAR-14:25 38.88 10-MAR-13:40 347.09 02-MAR-14:30 0.00
April 0.286930E+09 64607448.07 68.28 0.275225E+09 11705705.61 0.00 0.63 27-APR-14:30 0.00 01-APR-00:10 3955.65 27-APR-14:30 3734.19 27-APR-14:30 408.83 28-APR-13:02 902.52 27-APR-14:40 0.00
May 0.530036E+09 0.118637E+09 130.85 0.492615E+09 37420777.83 0.00 0.49 04-MAY-14:00 0.00 01-MAY-00:10 3011.24 04-MAY-14:00 2936.32 15-MAY-14:00 360.90 05-MAY-13:15 671.21 04-MAY-14:00 0.00
June 0.921572E+09 0.205808E+09 193.55 0.854297E+09 67274701.04 0.00 0.53 28-JUN-14:05 0.00 01-JUN-00:10 3244.75 28-JUN-14:05 3085.60 28-JUN-14:30 354.43 12-JUN-14:50 736.83 28-JUN-14:30 0.00
July 0.163590E+10 0.362674E+09 214.51 0.146347E+10 0.172434E+09 0.00 1.00 24-JUL-05:01 0.00 01-JUL-00:10 6938.19 31-JUL-05:02 6789.85 24-JUL-05:01 751.75 25-JUL-05:02 1356.27 31-JUL-05:02 0.00
August 0.255238E+10 0.566084E+09 258.35 0.225030E+10 0.302074E+09 0.00 1.00 01-AUG-05:02 0.00 01-AUG-00:10 6997.24 25-AUG-05:02 6740.96 09-AUG-05:02 1016.07 31-AUG-05:02 1364.78 25-AUG-05:02 0.00
September 0.161686E+10 0.346118E+09 195.15 0.144702E+10 0.169833E+09 0.00 1.00 11-SEP-05:02 0.00 01-SEP-00:10 6936.84 14-SEP-05:02 6819.50 11-SEP-05:02 869.30 14-SEP-12:05 1356.07 14-SEP-05:02 0.00
October 0.623543E+09 0.135295E+09 112.58 0.610275E+09 13267891.54 0.00 0.77 04-OCT-14:00 0.00 01-OCT-00:10 4812.34 04-OCT-14:00 4812.34 04-OCT-14:00 225.40 06-OCT-10:43 985.12 04-OCT-14:05 0.00
November 20758440.00 4711033.23 11.79 19369690.34 1388749.66 0.00 0.18 02-NOV-13:30 0.00 01-NOV-00:10 1067.23 02-NOV-13:30 952.22 02-NOV-13:30 115.01 02-NOV-13:30 239.90 02-NOV-13:30 0.00
December 5637787.05 1279713.69 3.08 5637787.05 0.00 0.00 0.13 05-DEC-14:30 0.00 01-DEC-00:10 708.06 05-DEC-14:30 708.06 05-DEC-14:30 0.00 05-DEC-13:50 160.17 05-DEC-14:30 0.00
                                       
Annual Sum or Average 0.829628E+10 0.182827E+10 1232.40 0.752059E+10 0.775691E+09 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.255238E+10 0.566084E+09 258.35 0.225030E+10 0.302074E+09 0.00 1.00   0.00   6997.24   6819.50   1016.07   1364.78   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:3 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00
April 94592788.73 21571820.04 48.45 90766645.65 3826143.08 0.00 0.90 28-APR-12:02 0.00 01-APR-00:10 3487.63 28-APR-12:02 2983.79 28-APR-12:02 503.84 28-APR-12:02 696.55 28-APR-12:02 0.00
May 0.295108E+09 66071894.98 142.83 0.277069E+09 18038419.40 0.00 0.94 15-MAY-10:02 0.00 01-MAY-00:10 3595.27 15-MAY-10:02 3588.10 15-MAY-10:02 403.49 08-MAY-14:02 713.97 15-MAY-10:02 0.00
June 0.702407E+09 0.155520E+09 226.32 0.660215E+09 42192298.78 0.00 0.96 28-JUN-10:02 0.00 01-JUN-00:10 3724.79 28-JUN-10:02 3615.47 28-JUN-10:02 253.08 12-JUN-10:05 737.51 28-JUN-10:02 0.00
July 0.100644E+10 0.222083E+09 227.69 0.922858E+09 83585116.09 0.00 1.00 24-JUL-05:01 0.00 01-JUL-00:10 4027.71 31-JUL-05:02 3962.74 24-JUL-05:01 570.25 11-JUL-10:02 807.64 24-JUL-10:02 0.00
August 0.139230E+10 0.309315E+09 266.24 0.125323E+10 0.139069E+09 0.00 1.00 01-AUG-05:02 0.00 01-AUG-00:10 4062.49 25-AUG-05:02 3898.92 15-AUG-05:02 721.83 02-AUG-10:01 825.26 29-AUG-10:02 0.00
September 0.650702E+09 0.142556E+09 189.91 0.582851E+09 67851707.81 0.00 1.00 11-SEP-10:02 0.00 01-SEP-00:10 3942.46 14-SEP-10:02 3825.04 11-SEP-05:02 626.92 22-SEP-10:02 773.73 14-SEP-10:02 0.00
October 0.132414E+09 29566861.56 68.40 0.129116E+09 3298330.57 0.00 0.76 04-OCT-10:02 0.00 01-OCT-00:10 2800.93 04-OCT-10:02 2800.93 04-OCT-10:02 255.50 06-OCT-10:02 573.47 04-OCT-10:02 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00
                                       
Annual Sum or Average 0.427397E+10 0.946685E+09 1169.84 0.391611E+10 0.357861E+09 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.139230E+10 0.309315E+09 266.24 0.125323E+10 0.139069E+09 0.00 1.00   0.00   4062.49   3962.74   721.83   825.26   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:4 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00 01-FEB-00:10 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00 01-MAR-00:10 0.00
April 47345308.75 10983040.26 16.35 42801063.66 4544245.08 0.00 0.45 27-APR-15:58 0.00 01-APR-00:10 1656.62 27-APR-15:58 1519.01 27-APR-15:53 196.70 28-APR-13:23 390.72 27-APR-15:58 0.00
May 0.236290E+09 52961465.55 98.14 0.210552E+09 25737679.62 0.00 0.53 05-MAY-15:50 0.00 01-MAY-00:10 1981.92 05-MAY-15:50 1702.30 05-MAY-15:50 280.05 05-MAY-16:00 443.56 05-MAY-16:00 0.00
June 0.704087E+09 0.155635E+09 196.65 0.635946E+09 68141288.19 0.00 0.64 28-JUN-16:00 0.00 01-JUN-00:10 2397.40 28-JUN-16:00 2266.74 28-JUN-15:53 330.59 12-JUN-15:00 540.23 28-JUN-16:00 0.00
July 0.121246E+10 0.265321E+09 221.72 0.106046E+10 0.152000E+09 0.00 1.00 24-JUL-05:01 0.00 01-JUL-00:10 4135.26 25-JUL-05:02 4054.36 24-JUL-05:01 514.87 25-JUL-05:02 809.29 25-JUL-05:02 0.00
August 0.162863E+10 0.359374E+09 260.24 0.139376E+10 0.234868E+09 0.00 1.00 01-AUG-05:02 0.00 01-AUG-00:10 4180.18 25-AUG-05:02 3897.11 09-AUG-05:02 695.10 25-AUG-05:02 815.97 25-AUG-05:02 0.00
September 0.648633E+09 0.142336E+09 170.11 0.543892E+09 0.104741E+09 0.00 0.64 14-SEP-15:43 0.00 01-SEP-00:10 2479.07 14-SEP-15:43 2129.77 14-SEP-15:57 460.43 14-SEP-13:00 539.23 14-SEP-15:43 0.00
October 74170918.55 16602333.78 38.83 71270366.80 2900551.75 0.00 0.34 04-OCT-15:10 0.00 01-OCT-00:10 1195.66 04-OCT-15:10 1195.66 04-OCT-15:10 103.33 06-OCT-15:00 264.48 04-OCT-15:00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00
                                       
Annual Sum or Average 0.455162E+10 0.100321E+10 1002.04 0.395869E+10 0.592934E+09 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.162863E+10 0.359374E+09 260.24 0.139376E+10 0.234868E+09 0.00 1.00   0.00   4180.18   4054.36   695.10   815.97   0.00



Table of Contents

Report: DXReportMonthly

For: PSZ-AC:5 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL ELECTRICITY ENERGY [J] COOLING COIL TOTAL COOLING ENERGY {HOURS NON-ZERO} [HOURS] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL LATENT COOLING ENERGY [J] COOLING COIL CRANKCASE HEATER ELECTRICITY ENERGY [] COOLING COIL RUNTIME FRACTION {Maximum} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL RUNTIME FRACTION {MINIMUM} [] COOLING COIL RUNTIME FRACTION {TIMESTAMP} COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {Maximum} [W] COOLING COIL SENSIBLE COOLING RATE {TIMESTAMP} COOLING COIL LATENT COOLING RATE {Maximum} [W] COOLING COIL LATENT COOLING RATE {TIMESTAMP} COOLING COIL ELECTRICITY RATE {Maximum} [W] COOLING COIL ELECTRICITY RATE {TIMESTAMP} COOLING COIL CRANKCASE HEATER ELECTRICITY RATE []
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00 01-JAN-00:10 0.00
February 76367.91 17623.33 0.67 75616.33 751.58 0.00 0.02 27-FEB-15:57 0.00 01-FEB-00:10 71.76 27-FEB-15:57 71.09 27-FEB-15:57 0.67 27-FEB-15:57 16.54 27-FEB-15:57 0.00
March 3934244.10 899511.45 5.15 3928849.38 5394.72 0.00 0.10 02-MAR-16:35 0.00 01-MAR-00:10 400.55 02-MAR-16:35 400.55 02-MAR-16:35 2.71 14-MAR-16:00 91.11 02-MAR-16:40 0.00
April 0.108420E+09 24850403.31 45.31 0.101709E+09 6711030.21 0.00 0.52 27-APR-15:53 0.00 01-APR-00:10 2226.75 27-APR-15:53 2071.99 27-APR-15:55 174.86 28-APR-13:45 521.24 27-APR-15:53 0.00
May 0.383484E+09 86105918.03 162.54 0.353808E+09 29675996.73 0.00 0.55 15-MAY-16:00 0.00 01-MAY-00:10 2322.51 15-MAY-15:57 2322.51 15-MAY-15:57 252.71 08-MAY-15:55 514.75 15-MAY-15:57 0.00
June 0.718710E+09 0.160665E+09 226.02 0.664729E+09 53981280.65 0.00 0.72 23-JUN-05:02 0.00 01-JUN-00:10 3232.61 23-JUN-05:02 3091.25 23-JUN-05:02 218.44 29-JUN-05:02 665.98 23-JUN-05:02 0.00
July 0.115592E+10 0.257247E+09 235.58 0.104159E+10 0.114333E+09 0.00 1.00 24-JUL-05:01 0.00 01-JUL-00:10 4846.07 31-JUL-05:02 4770.77 24-JUL-05:01 587.59 27-JUL-05:02 946.77 31-JUL-05:02 0.00
August 0.147941E+10 0.333508E+09 269.20 0.130560E+10 0.173814E+09 0.00 1.00 01-AUG-05:02 0.00 01-AUG-00:10 4881.73 25-AUG-05:02 4747.04 15-AUG-05:02 641.81 25-AUG-05:02 951.83 25-AUG-05:02 0.00
September 0.769720E+09 0.170155E+09 207.40 0.677595E+09 92125486.65 0.00 1.00 11-SEP-05:02 0.00 01-SEP-00:10 4809.60 14-SEP-05:02 4700.54 11-SEP-05:02 494.64 14-SEP-05:02 941.27 14-SEP-05:02 0.00
October 0.168648E+09 37685481.52 79.20 0.163624E+09 5023996.29 0.00 0.49 04-OCT-16:00 0.00 01-OCT-00:10 2072.30 04-OCT-15:57 2072.30 04-OCT-15:57 90.65 06-OCT-15:15 443.55 04-OCT-15:57 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00 01-NOV-00:10 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00 01-DEC-00:10 0.00
                                       
Annual Sum or Average 0.478833E+10 0.107113E+10 1231.07 0.431266E+10 0.475671E+09 0.00                         0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00   0.00   0.00   0.00   0.00   0.00   0.00
Maximum of Months 0.147941E+10 0.333508E+09 269.20 0.130560E+10 0.173814E+09 0.00 1.00   0.00   4881.73   4770.77   641.81   951.83   0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 44.56 26.92 17.64 42.11 51.01 0.00 0.00 0.00
February 68.62 43.15 25.47 73.60 46.16 0.00 0.00 0.00
March 73.47 39.99 33.47 81.86 40.85 0.00 0.00 0.00
April 71.21 30.00 41.21 82.11 34.33 0.00 0.00 0.00
May 57.54 13.29 44.25 62.67 29.79 0.00 0.00 0.00
June 49.54 8.03 41.51 52.56 23.99 0.00 0.00 0.00
July 54.55 14.66 39.88 65.63 22.72 0.00 0.00 0.00
August 65.71 28.07 37.63 85.54 22.98 0.00 0.00 0.00
September 83.31 46.57 36.74 104.32 32.35 0.00 0.00 0.00
October 76.76 48.09 28.67 88.96 40.46 0.00 0.00 0.00
November 45.18 26.39 18.79 44.86 45.39 0.00 0.00 0.00
December 47.56 31.18 16.38 48.91 53.44 0.00 0.00 0.00
                 
Annual Sum or Average 61.43 29.61 31.83 69.38 36.91 0.00 0.00 0.00
Minimum of Months 44.56 8.03 16.38 42.11 22.72 0.00 0.00 0.00
Maximum of Months 83.31 48.09 44.25 104.32 53.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 44.55 26.92 17.64 42.11 51.01 0.00 0.00 0.00
February 68.62 43.15 25.47 73.60 46.16 0.00 0.00 0.00
March 73.47 39.99 33.47 81.86 40.85 0.00 0.00 0.00
April 71.12 29.97 41.15 81.96 34.36 0.00 0.00 0.00
May 57.46 13.26 44.20 62.52 29.79 0.00 0.00 0.00
June 49.51 8.02 41.49 52.52 23.99 0.00 0.00 0.00
July 54.49 14.63 39.86 65.52 22.72 0.00 0.00 0.00
August 65.59 28.01 37.58 85.30 22.98 0.00 0.00 0.00
September 83.26 46.55 36.71 104.23 32.37 0.00 0.00 0.00
October 76.75 48.09 28.66 88.96 40.46 0.00 0.00 0.00
November 45.18 26.39 18.79 44.86 45.39 0.00 0.00 0.00
December 47.56 31.18 16.38 48.91 53.44 0.00 0.00 0.00
                 
Annual Sum or Average 61.40 29.59 31.80 69.31 36.92 0.00 0.00 0.00
Minimum of Months 44.55 8.02 16.38 42.11 22.72 0.00 0.00 0.00
Maximum of Months 83.26 48.09 44.20 104.23 53.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 44.55 26.92 17.64 42.11 51.01 0.00 0.00 0.00
February 68.62 43.15 25.47 73.60 46.16 0.00 0.00 0.00
March 73.47 39.99 33.47 81.86 40.85 0.00 0.00 0.00
April 71.12 29.97 41.15 81.96 34.36 0.00 0.00 0.00
May 57.46 13.26 44.20 62.52 29.79 0.00 0.00 0.00
June 49.51 8.02 41.49 52.52 23.99 0.00 0.00 0.00
July 54.49 14.63 39.86 65.52 22.72 0.00 0.00 0.00
August 65.59 28.01 37.58 85.30 22.98 0.00 0.00 0.00
September 83.26 46.55 36.70 104.23 32.37 0.00 0.00 0.00
October 76.75 48.09 28.66 88.96 40.46 0.00 0.00 0.00
November 45.18 26.39 18.79 44.86 45.39 0.00 0.00 0.00
December 47.56 31.18 16.38 48.91 53.44 0.00 0.00 0.00
                 
Annual Sum or Average 61.40 29.59 31.80 69.31 36.92 0.00 0.00 0.00
Minimum of Months 44.55 8.02 16.38 42.11 22.72 0.00 0.00 0.00
Maximum of Months 83.26 48.09 44.20 104.23 53.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 44.55 26.92 17.64 42.11 51.01 0.00 0.00 0.00
February 68.62 43.15 25.47 73.60 46.16 0.00 0.00 0.00
March 73.47 39.99 33.47 81.86 40.85 0.00 0.00 0.00
April 71.12 29.97 41.15 81.96 34.36 0.00 0.00 0.00
May 57.46 13.26 44.20 62.52 29.79 0.00 0.00 0.00
June 49.51 8.02 41.49 52.52 23.99 0.00 0.00 0.00
July 54.49 14.63 39.86 65.52 22.72 0.00 0.00 0.00
August 65.59 28.01 37.58 85.30 22.98 0.00 0.00 0.00
September 83.26 46.55 36.70 104.23 32.37 0.00 0.00 0.00
October 76.75 48.09 28.66 88.96 40.46 0.00 0.00 0.00
November 45.18 26.39 18.79 44.86 45.39 0.00 0.00 0.00
December 47.56 31.18 16.38 48.91 53.44 0.00 0.00 0.00
                 
Annual Sum or Average 61.40 29.59 31.80 69.31 36.92 0.00 0.00 0.00
Minimum of Months 44.55 8.02 16.38 42.11 22.72 0.00 0.00 0.00
Maximum of Months 83.26 48.09 44.20 104.23 53.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 44.55 26.92 17.64 42.11 51.01 0.00 0.00 0.00
February 68.62 43.15 25.47 73.60 46.16 0.00 0.00 0.00
March 73.47 39.99 33.47 81.86 40.85 0.00 0.00 0.00
April 71.12 29.97 41.15 81.96 34.36 0.00 0.00 0.00
May 57.46 13.26 44.20 62.52 29.79 0.00 0.00 0.00
June 49.51 8.02 41.49 52.52 23.99 0.00 0.00 0.00
July 54.49 14.63 39.86 65.52 22.72 0.00 0.00 0.00
August 65.59 28.01 37.58 85.30 22.98 0.00 0.00 0.00
September 83.26 46.56 36.71 104.23 32.36 0.00 0.00 0.00
October 76.75 48.09 28.66 88.96 40.46 0.00 0.00 0.00
November 45.18 26.39 18.79 44.86 45.39 0.00 0.00 0.00
December 47.56 31.18 16.38 48.91 53.44 0.00 0.00 0.00
                 
Annual Sum or Average 61.40 29.59 31.80 69.31 36.92 0.00 0.00 0.00
Minimum of Months 44.55 8.02 16.38 42.11 22.72 0.00 0.00 0.00
Maximum of Months 83.26 48.09 44.20 104.23 53.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 44.56 26.92 17.64 42.11 51.01 0.00 0.00 0.00
February 68.62 43.15 25.47 73.60 46.16 0.00 0.00 0.00
March 73.47 39.99 33.47 81.86 40.85 0.00 0.00 0.00
April 71.22 30.01 41.21 82.07 34.27 0.00 0.00 0.00
May 57.52 13.28 44.24 62.63 29.79 0.00 0.00 0.00
June 49.54 8.03 41.51 52.57 23.99 0.00 0.00 0.00
July 54.53 14.65 39.88 65.60 22.72 0.00 0.00 0.00
August 65.71 28.07 37.64 85.53 22.98 0.00 0.00 0.00
September 83.30 46.57 36.73 104.27 32.31 0.00 0.00 0.00
October 76.76 48.09 28.67 88.96 40.46 0.00 0.00 0.00
November 45.18 26.39 18.79 44.86 45.39 0.00 0.00 0.00
December 47.56 31.18 16.38 48.91 53.44 0.00 0.00 0.00
                 
Annual Sum or Average 61.43 29.61 31.82 69.36 36.90 0.00 0.00 0.00
Minimum of Months 44.56 8.03 16.38 42.11 22.72 0.00 0.00 0.00
Maximum of Months 83.30 48.09 44.24 104.27 53.44 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_DOOR

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 62.96 37.71 25.25 59.59 70.97 0.00 0.00 0.00
February 96.90 60.46 36.44 103.99 64.31 0.00 0.00 0.00
March 103.98 56.03 47.95 115.86 56.83 0.00 0.00 0.00
April 109.04 47.90 61.15 128.80 47.72 0.00 0.00 0.00
May 93.07 25.94 67.13 107.24 41.47 0.00 0.00 0.00
June 81.21 18.36 62.84 92.72 33.44 0.00 0.00 0.00
July 90.20 30.14 60.06 114.20 31.76 0.00 0.00 0.00
August 104.66 48.60 56.05 139.29 32.20 0.00 0.00 0.00
September 119.39 66.52 52.87 149.77 45.22 0.00 0.00 0.00
October 108.32 67.38 40.94 125.48 56.44 0.00 0.00 0.00
November 63.90 36.97 26.93 63.50 63.16 0.00 0.00 0.00
December 67.06 43.68 23.38 68.88 74.38 0.00 0.00 0.00
                 
Annual Sum or Average 91.66 44.88 46.79 105.76 51.43 0.00 0.00 0.00
Minimum of Months 62.96 18.36 23.38 59.59 31.76 0.00 0.00 0.00
Maximum of Months 119.39 67.38 67.13 149.77 74.38 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 15.54 4.11 11.43 6.33 52.33 0.00 0.00 0.00
February 28.66 10.47 18.18 20.70 45.18 0.00 0.00 0.00
March 42.54 15.69 26.85 38.20 37.61 0.00 0.00 0.00
April 65.87 27.72 38.15 70.05 30.58 0.00 0.00 0.00
May 68.80 23.86 44.94 74.71 27.54 0.00 0.00 0.00
June 82.87 35.92 46.95 95.29 22.54 0.00 0.00 0.00
July 77.18 34.22 42.96 92.12 20.37 0.00 0.00 0.00
August 77.10 38.69 38.42 95.39 20.63 0.00 0.00 0.00
September 57.34 26.77 30.56 63.20 29.34 0.00 0.00 0.00
October 37.44 16.24 21.20 34.85 37.81 0.00 0.00 0.00
November 18.18 5.33 12.85 10.25 44.91 0.00 0.00 0.00
December 15.04 5.02 10.02 7.92 53.83 0.00 0.00 0.00
                 
Annual Sum or Average 48.97 20.38 28.59 50.90 35.18 0.00 0.00 0.00
Minimum of Months 15.04 4.11 10.02 6.33 20.37 0.00 0.00 0.00
Maximum of Months 82.87 38.69 46.95 95.39 53.83 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 15.54 4.11 11.43 6.33 52.33 0.00 0.00 0.00
February 28.65 10.47 18.18 20.70 45.18 0.00 0.00 0.00
March 42.54 15.69 26.85 38.20 37.61 0.00 0.00 0.00
April 65.87 27.72 38.15 70.04 30.58 0.00 0.00 0.00
May 68.80 23.86 44.93 74.71 27.54 0.00 0.00 0.00
June 82.87 35.92 46.95 95.29 22.54 0.00 0.00 0.00
July 77.18 34.22 42.95 92.12 20.37 0.00 0.00 0.00
August 77.10 38.69 38.42 95.39 20.63 0.00 0.00 0.00
September 57.34 26.77 30.56 63.20 29.34 0.00 0.00 0.00
October 37.44 16.24 21.20 34.85 37.81 0.00 0.00 0.00
November 18.18 5.33 12.85 10.25 44.91 0.00 0.00 0.00
December 15.04 5.02 10.02 7.92 53.83 0.00 0.00 0.00
                 
Annual Sum or Average 48.97 20.38 28.59 50.90 35.18 0.00 0.00 0.00
Minimum of Months 15.04 4.11 10.02 6.33 20.37 0.00 0.00 0.00
Maximum of Months 82.87 38.69 46.95 95.39 53.83 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 15.54 4.11 11.43 6.33 52.33 0.00 0.00 0.00
February 28.65 10.47 18.18 20.70 45.18 0.00 0.00 0.00
March 42.54 15.69 26.85 38.20 37.61 0.00 0.00 0.00
April 65.87 27.72 38.15 70.04 30.58 0.00 0.00 0.00
May 68.80 23.86 44.93 74.71 27.54 0.00 0.00 0.00
June 82.87 35.92 46.95 95.29 22.54 0.00 0.00 0.00
July 77.18 34.22 42.95 92.12 20.37 0.00 0.00 0.00
August 77.10 38.69 38.42 95.39 20.63 0.00 0.00 0.00
September 57.34 26.77 30.56 63.20 29.34 0.00 0.00 0.00
October 37.44 16.24 21.20 34.85 37.81 0.00 0.00 0.00
November 18.18 5.33 12.85 10.25 44.91 0.00 0.00 0.00
December 15.04 5.02 10.02 7.92 53.83 0.00 0.00 0.00
                 
Annual Sum or Average 48.97 20.38 28.59 50.90 35.18 0.00 0.00 0.00
Minimum of Months 15.04 4.11 10.02 6.33 20.37 0.00 0.00 0.00
Maximum of Months 82.87 38.69 46.95 95.39 53.83 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 15.60 4.13 11.47 6.39 52.28 0.00 0.00 0.00
February 28.72 10.50 18.22 20.80 45.16 0.00 0.00 0.00
March 42.56 15.70 26.86 38.23 37.61 0.00 0.00 0.00
April 65.87 27.72 38.15 70.05 30.58 0.00 0.00 0.00
May 68.80 23.86 44.94 74.71 27.54 0.00 0.00 0.00
June 82.87 35.92 46.95 95.29 22.54 0.00 0.00 0.00
July 77.18 34.22 42.96 92.12 20.37 0.00 0.00 0.00
August 77.10 38.69 38.42 95.39 20.63 0.00 0.00 0.00
September 57.34 26.77 30.57 63.20 29.34 0.00 0.00 0.00
October 37.48 16.26 21.22 34.93 37.81 0.00 0.00 0.00
November 18.23 5.35 12.89 10.34 44.89 0.00 0.00 0.00
December 15.11 5.05 10.06 8.02 53.79 0.00 0.00 0.00
                 
Annual Sum or Average 48.99 20.39 28.60 50.94 35.17 0.00 0.00 0.00
Minimum of Months 15.11 4.13 10.06 6.39 20.37 0.00 0.00 0.00
Maximum of Months 82.87 38.69 46.95 95.39 53.79 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 9.48 0.00 9.48 0.49 55.32 0.00 0.00 0.00
February 14.87 0.00 14.87 4.00 47.97 0.00 0.00 0.00
March 22.00 0.00 22.00 11.67 38.78 0.00 0.00 0.00
April 31.35 0.11 31.23 24.22 30.66 0.00 0.00 0.00
May 40.26 1.19 39.07 35.71 26.71 0.00 0.00 0.00
June 42.52 2.77 39.75 40.20 21.30 0.00 0.00 0.00
July 40.69 3.16 37.52 42.74 19.87 0.00 0.00 0.00
August 32.91 0.90 32.01 35.12 19.91 0.00 0.00 0.00
September 25.44 0.01 25.43 20.36 29.49 0.00 0.00 0.00
October 17.31 0.00 17.31 8.63 38.12 0.00 0.00 0.00
November 10.74 0.00 10.74 1.78 46.41 0.00 0.00 0.00
December 8.10 0.00 8.10 0.36 56.26 0.00 0.00 0.00
                 
Annual Sum or Average 24.69 0.68 24.00 18.86 35.84 0.00 0.00 0.00
Minimum of Months 8.10 0.00 8.10 0.36 19.87 0.00 0.00 0.00
Maximum of Months 42.52 3.16 39.75 42.74 56.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 9.48 0.00 9.48 0.49 55.32 0.00 0.00 0.00
February 14.87 0.00 14.87 4.00 47.97 0.00 0.00 0.00
March 21.99 0.00 21.99 11.67 38.78 0.00 0.00 0.00
April 31.33 0.11 31.22 24.22 30.69 0.00 0.00 0.00
May 40.20 1.18 39.03 35.61 26.73 0.00 0.00 0.00
June 42.42 2.73 39.69 40.00 21.30 0.00 0.00 0.00
July 40.60 3.12 37.48 42.58 19.88 0.00 0.00 0.00
August 32.84 0.88 31.96 35.03 19.95 0.00 0.00 0.00
September 25.44 0.01 25.43 20.36 29.49 0.00 0.00 0.00
October 17.31 0.00 17.31 8.63 38.12 0.00 0.00 0.00
November 10.74 0.00 10.74 1.78 46.41 0.00 0.00 0.00
December 8.10 0.00 8.10 0.36 56.26 0.00 0.00 0.00
                 
Annual Sum or Average 24.66 0.67 23.99 18.82 35.85 0.00 0.00 0.00
Minimum of Months 8.10 0.00 8.10 0.36 19.88 0.00 0.00 0.00
Maximum of Months 42.42 3.12 39.69 42.58 56.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 9.48 0.00 9.48 0.49 55.32 0.00 0.00 0.00
February 14.87 0.00 14.87 4.00 47.97 0.00 0.00 0.00
March 21.99 0.00 21.99 11.67 38.78 0.00 0.00 0.00
April 31.32 0.11 31.21 24.22 30.71 0.00 0.00 0.00
May 40.20 1.18 39.03 35.61 26.73 0.00 0.00 0.00
June 42.42 2.73 39.69 40.00 21.30 0.00 0.00 0.00
July 40.60 3.12 37.48 42.58 19.88 0.00 0.00 0.00
August 32.84 0.88 31.96 35.03 19.95 0.00 0.00 0.00
September 25.44 0.01 25.43 20.36 29.49 0.00 0.00 0.00
October 17.31 0.00 17.31 8.63 38.12 0.00 0.00 0.00
November 10.74 0.00 10.74 1.78 46.41 0.00 0.00 0.00
December 8.10 0.00 8.10 0.36 56.26 0.00 0.00 0.00
                 
Annual Sum or Average 24.66 0.67 23.98 18.82 35.85 0.00 0.00 0.00
Minimum of Months 8.10 0.00 8.10 0.36 19.88 0.00 0.00 0.00
Maximum of Months 42.42 3.12 39.69 42.58 56.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 9.48 0.00 9.48 0.49 55.32 0.00 0.00 0.00
February 14.87 0.00 14.87 4.00 47.97 0.00 0.00 0.00
March 21.99 0.00 21.99 11.67 38.78 0.00 0.00 0.00
April 31.32 0.11 31.21 24.22 30.71 0.00 0.00 0.00
May 40.20 1.18 39.03 35.61 26.73 0.00 0.00 0.00
June 42.42 2.73 39.69 40.00 21.30 0.00 0.00 0.00
July 40.60 3.12 37.48 42.58 19.88 0.00 0.00 0.00
August 32.84 0.88 31.96 35.03 19.95 0.00 0.00 0.00
September 25.44 0.01 25.43 20.36 29.49 0.00 0.00 0.00
October 17.31 0.00 17.31 8.63 38.12 0.00 0.00 0.00
November 10.74 0.00 10.74 1.78 46.41 0.00 0.00 0.00
December 8.10 0.00 8.10 0.36 56.26 0.00 0.00 0.00
                 
Annual Sum or Average 24.66 0.67 23.98 18.82 35.85 0.00 0.00 0.00
Minimum of Months 8.10 0.00 8.10 0.36 19.88 0.00 0.00 0.00
Maximum of Months 42.42 3.12 39.69 42.58 56.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 9.48 0.00 9.48 0.49 55.32 0.00 0.00 0.00
February 14.87 0.00 14.87 4.00 47.97 0.00 0.00 0.00
March 21.99 0.00 21.99 11.67 38.78 0.00 0.00 0.00
April 31.33 0.11 31.22 24.23 30.70 0.00 0.00 0.00
May 40.20 1.18 39.03 35.61 26.73 0.00 0.00 0.00
June 42.42 2.73 39.69 40.00 21.30 0.00 0.00 0.00
July 40.60 3.12 37.48 42.58 19.88 0.00 0.00 0.00
August 32.84 0.88 31.96 35.03 19.95 0.00 0.00 0.00
September 25.44 0.01 25.43 20.36 29.49 0.00 0.00 0.00
October 17.31 0.00 17.31 8.63 38.12 0.00 0.00 0.00
November 10.74 0.00 10.74 1.78 46.41 0.00 0.00 0.00
December 8.10 0.00 8.10 0.36 56.26 0.00 0.00 0.00
                 
Annual Sum or Average 24.66 0.67 23.99 18.82 35.85 0.00 0.00 0.00
Minimum of Months 8.10 0.00 8.10 0.36 19.88 0.00 0.00 0.00
Maximum of Months 42.42 3.12 39.69 42.58 56.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_6

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 9.48 0.00 9.48 0.49 55.32 0.00 0.00 0.00
February 14.87 0.00 14.87 4.00 47.97 0.00 0.00 0.00
March 22.00 0.00 22.00 11.67 38.78 0.00 0.00 0.00
April 31.35 0.11 31.24 24.25 30.69 0.00 0.00 0.00
May 40.30 1.21 39.09 35.79 26.72 0.00 0.00 0.00
June 42.52 2.76 39.75 40.19 21.30 0.00 0.00 0.00
July 40.72 3.18 37.54 42.82 19.88 0.00 0.00 0.00
August 32.90 0.90 32.00 35.15 19.95 0.00 0.00 0.00
September 25.44 0.01 25.43 20.36 29.49 0.00 0.00 0.00
October 17.31 0.00 17.31 8.63 38.12 0.00 0.00 0.00
November 10.74 0.00 10.74 1.78 46.41 0.00 0.00 0.00
December 8.10 0.00 8.10 0.36 56.26 0.00 0.00 0.00
                 
Annual Sum or Average 24.69 0.69 24.01 18.88 35.85 0.00 0.00 0.00
Minimum of Months 8.10 0.00 8.10 0.36 19.88 0.00 0.00 0.00
Maximum of Months 42.52 3.18 39.75 42.82 56.26 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 16.50 5.07 11.42 8.09 53.10 0.00 0.00 0.00
February 29.66 11.46 18.20 23.08 46.37 0.00 0.00 0.00
March 41.11 14.14 26.96 37.17 38.96 0.00 0.00 0.00
April 62.19 23.94 38.25 66.06 32.27 0.00 0.00 0.00
May 79.51 32.52 46.98 89.58 29.31 0.00 0.00 0.00
June 76.29 29.41 46.88 86.90 23.78 0.00 0.00 0.00
July 95.28 50.17 45.11 117.94 23.11 0.00 0.00 0.00
August 79.44 40.75 38.69 100.00 22.91 0.00 0.00 0.00
September 65.17 31.63 33.54 75.64 31.42 0.00 0.00 0.00
October 37.13 15.45 21.69 35.23 39.20 0.00 0.00 0.00
November 18.38 5.40 12.98 10.96 45.59 0.00 0.00 0.00
December 15.62 5.55 10.06 9.51 54.70 0.00 0.00 0.00
                 
Annual Sum or Average 51.49 22.21 29.28 55.22 36.69 0.00 0.00 0.00
Minimum of Months 15.62 5.07 10.06 8.09 22.91 0.00 0.00 0.00
Maximum of Months 95.28 50.17 46.98 117.94 54.70 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 16.43 5.05 11.38 8.02 53.15 0.00 0.00 0.00
February 29.61 11.44 18.17 22.98 46.38 0.00 0.00 0.00
March 41.09 14.13 26.95 37.13 38.96 0.00 0.00 0.00
April 62.19 23.94 38.25 66.06 32.27 0.00 0.00 0.00
May 79.51 32.52 46.98 89.57 29.31 0.00 0.00 0.00
June 76.28 29.41 46.87 86.90 23.78 0.00 0.00 0.00
July 95.28 50.17 45.11 117.94 23.11 0.00 0.00 0.00
August 79.44 40.75 38.68 99.99 22.91 0.00 0.00 0.00
September 65.16 31.63 33.53 75.63 31.42 0.00 0.00 0.00
October 37.09 15.43 21.66 35.15 39.20 0.00 0.00 0.00
November 18.33 5.38 12.95 10.88 45.60 0.00 0.00 0.00
December 15.55 5.53 10.02 9.43 54.74 0.00 0.00 0.00
                 
Annual Sum or Average 51.46 22.20 29.26 55.18 36.69 0.00 0.00 0.00
Minimum of Months 15.55 5.05 10.02 8.02 22.91 0.00 0.00 0.00
Maximum of Months 95.28 50.17 46.98 117.94 54.74 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 16.43 5.05 11.38 8.02 53.15 0.00 0.00 0.00
February 29.61 11.44 18.17 22.98 46.38 0.00 0.00 0.00
March 41.09 14.13 26.95 37.13 38.96 0.00 0.00 0.00
April 62.19 23.94 38.25 66.06 32.27 0.00 0.00 0.00
May 79.51 32.52 46.98 89.57 29.31 0.00 0.00 0.00
June 76.28 29.41 46.87 86.90 23.78 0.00 0.00 0.00
July 95.28 50.17 45.11 117.94 23.11 0.00 0.00 0.00
August 79.44 40.75 38.68 99.99 22.91 0.00 0.00 0.00
September 65.16 31.63 33.53 75.63 31.42 0.00 0.00 0.00
October 37.09 15.43 21.66 35.15 39.20 0.00 0.00 0.00
November 18.33 5.38 12.95 10.88 45.60 0.00 0.00 0.00
December 15.55 5.53 10.02 9.43 54.74 0.00 0.00 0.00
                 
Annual Sum or Average 51.46 22.20 29.26 55.18 36.69 0.00 0.00 0.00
Minimum of Months 15.55 5.05 10.02 8.02 22.91 0.00 0.00 0.00
Maximum of Months 95.28 50.17 46.98 117.94 54.74 0.00 0.00 0.00



Table of Contents

Report: WindowReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION RATE [W] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] SURFACE WINDOW HEAT GAIN RATE [W] SURFACE WINDOW HEAT LOSS RATE [W] SURFACE WINDOW INSIDE FACE GLAZING CONDENSATION STATUS {HOURS NON-ZERO} [HOURS] SURFACE SHADING DEVICE IS ON TIME FRACTION {HOURS NON-ZERO} [HOURS] SURFACE STORM WINDOW ON OFF STATUS {HOURS NON-ZERO} [HOURS]
January 16.43 5.05 11.38 8.02 53.15 0.00 0.00 0.00
February 29.61 11.44 18.17 22.99 46.38 0.00 0.00 0.00
March 41.09 14.13 26.96 37.13 38.96 0.00 0.00 0.00
April 62.19 23.94 38.25 66.06 32.27 0.00 0.00 0.00
May 79.51 32.52 46.98 89.58 29.31 0.00 0.00 0.00
June 76.29 29.41 46.88 86.90 23.78 0.00 0.00 0.00
July 95.28 50.17 45.11 117.94 23.11 0.00 0.00 0.00
August 79.44 40.75 38.69 100.00 22.91 0.00 0.00 0.00
September 65.16 31.63 33.54 75.63 31.42 0.00 0.00 0.00
October 37.09 15.43 21.66 35.15 39.20 0.00 0.00 0.00
November 18.33 5.38 12.95 10.88 45.60 0.00 0.00 0.00
December 15.55 5.53 10.02 9.43 54.74 0.00 0.00 0.00
                 
Annual Sum or Average 51.46 22.20 29.27 55.18 36.69 0.00 0.00 0.00
Minimum of Months 15.55 5.05 10.02 8.02 22.91 0.00 0.00 0.00
Maximum of Months 95.28 50.17 46.98 117.94 54.74 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.119338E+09 72099289.74 47238653.37 0.112792E+09 0.136631E+09
February 0.166017E+09 0.104399E+09 61617363.65 0.178050E+09 0.111666E+09
March 0.196774E+09 0.107117E+09 89656666.41 0.219259E+09 0.109418E+09
April 0.184580E+09 77760607.54 0.106820E+09 0.212821E+09 88978858.62
May 0.154119E+09 35593635.22 0.118526E+09 0.167865E+09 79787147.68
June 0.128396E+09 20802134.91 0.107593E+09 0.136247E+09 62185444.71
July 0.146094E+09 39272511.45 0.106822E+09 0.175796E+09 60856299.57
August 0.175989E+09 75189096.78 0.100800E+09 0.229113E+09 61553026.88
September 0.215944E+09 0.120719E+09 95225398.04 0.270385E+09 83864041.13
October 0.205582E+09 0.128805E+09 76776924.71 0.238271E+09 0.108380E+09
November 0.117102E+09 68404645.43 48697520.77 0.116272E+09 0.117639E+09
December 0.127384E+09 83513387.45 43870346.91 0.130996E+09 0.143133E+09
           
Annual Sum or Average 0.193732E+10 0.933676E+09 0.100364E+10 0.218787E+10 0.116409E+10
Minimum of Months 0.117102E+09 20802134.91 43870346.91 0.112792E+09 60856299.57
Maximum of Months 0.215944E+09 0.128805E+09 0.118526E+09 0.270385E+09 0.143133E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.119336E+09 72099289.74 47236357.60 0.112790E+09 0.136630E+09
February 0.166014E+09 0.104399E+09 61614454.32 0.178047E+09 0.111665E+09
March 0.196769E+09 0.107117E+09 89652157.77 0.219255E+09 0.109417E+09
April 0.184335E+09 77673867.15 0.106661E+09 0.212436E+09 89056122.86
May 0.153900E+09 35509688.94 0.118391E+09 0.167446E+09 79788073.48
June 0.128336E+09 20784612.80 0.107551E+09 0.136138E+09 62185109.00
July 0.145947E+09 39196690.94 0.106750E+09 0.175486E+09 60855736.49
August 0.175676E+09 75029627.72 0.100646E+09 0.228459E+09 61552184.12
September 0.215811E+09 0.120670E+09 95141767.48 0.270175E+09 83903088.81
October 0.205579E+09 0.128805E+09 76773577.76 0.238268E+09 0.108379E+09
November 0.117100E+09 68404645.43 48695027.75 0.116270E+09 0.117638E+09
December 0.127382E+09 83513387.45 43868508.89 0.130995E+09 0.143132E+09
           
Annual Sum or Average 0.193618E+10 0.933203E+09 0.100298E+10 0.218576E+10 0.116420E+10
Minimum of Months 0.117100E+09 20784612.80 43868508.89 0.112790E+09 60855736.49
Maximum of Months 0.215811E+09 0.128805E+09 0.118391E+09 0.270175E+09 0.143132E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.119336E+09 72099289.74 47236357.60 0.112790E+09 0.136630E+09
February 0.166014E+09 0.104399E+09 61614454.32 0.178047E+09 0.111665E+09
March 0.196769E+09 0.107117E+09 89652157.77 0.219255E+09 0.109417E+09
April 0.184330E+09 77673327.85 0.106657E+09 0.212431E+09 89059460.51
May 0.153900E+09 35509688.94 0.118391E+09 0.167446E+09 79788073.48
June 0.128336E+09 20784612.80 0.107551E+09 0.136138E+09 62185109.00
July 0.145947E+09 39196690.94 0.106750E+09 0.175486E+09 60855736.49
August 0.175675E+09 75029290.76 0.100646E+09 0.228457E+09 61552168.17
September 0.215800E+09 0.120668E+09 95132528.10 0.270163E+09 83910063.23
October 0.205579E+09 0.128805E+09 76773577.76 0.238268E+09 0.108379E+09
November 0.117100E+09 68404645.43 48695027.75 0.116270E+09 0.117638E+09
December 0.127382E+09 83513387.45 43868508.89 0.130995E+09 0.143132E+09
           
Annual Sum or Average 0.193617E+10 0.933200E+09 0.100297E+10 0.218575E+10 0.116421E+10
Minimum of Months 0.117100E+09 20784612.80 43868508.89 0.112790E+09 60855736.49
Maximum of Months 0.215800E+09 0.128805E+09 0.118391E+09 0.270163E+09 0.143132E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.119336E+09 72099289.74 47236357.60 0.112790E+09 0.136630E+09
February 0.166014E+09 0.104399E+09 61614454.32 0.178047E+09 0.111665E+09
March 0.196769E+09 0.107117E+09 89652157.77 0.219255E+09 0.109417E+09
April 0.184330E+09 77673327.85 0.106657E+09 0.212431E+09 89059460.51
May 0.153900E+09 35509688.94 0.118391E+09 0.167446E+09 79788073.48
June 0.128336E+09 20784612.80 0.107551E+09 0.136138E+09 62185109.00
July 0.145947E+09 39196690.94 0.106750E+09 0.175486E+09 60855736.49
August 0.175675E+09 75029260.89 0.100646E+09 0.228457E+09 61551905.90
September 0.215802E+09 0.120668E+09 95133514.17 0.270161E+09 83906187.50
October 0.205579E+09 0.128805E+09 76773577.76 0.238268E+09 0.108379E+09
November 0.117100E+09 68404645.43 48695027.75 0.116270E+09 0.117638E+09
December 0.127382E+09 83513387.45 43868508.89 0.130995E+09 0.143132E+09
           
Annual Sum or Average 0.193617E+10 0.933200E+09 0.100297E+10 0.218574E+10 0.116421E+10
Minimum of Months 0.117100E+09 20784612.80 43868508.89 0.112790E+09 60855736.49
Maximum of Months 0.215802E+09 0.128805E+09 0.118391E+09 0.270161E+09 0.143132E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.119336E+09 72099289.74 47236357.60 0.112790E+09 0.136630E+09
February 0.166014E+09 0.104399E+09 61614454.32 0.178047E+09 0.111665E+09
March 0.196769E+09 0.107117E+09 89652157.77 0.219255E+09 0.109417E+09
April 0.184335E+09 77673972.91 0.106661E+09 0.212431E+09 89051969.54
May 0.153900E+09 35509688.94 0.118391E+09 0.167446E+09 79788073.48
June 0.128336E+09 20784612.80 0.107551E+09 0.136138E+09 62185109.00
July 0.145947E+09 39196690.94 0.106750E+09 0.175486E+09 60855736.49
August 0.175675E+09 75029562.26 0.100646E+09 0.228457E+09 61551575.67
September 0.215815E+09 0.120671E+09 95144620.21 0.270161E+09 83880315.35
October 0.205579E+09 0.128805E+09 76773577.76 0.238268E+09 0.108379E+09
November 0.117100E+09 68404645.43 48695027.75 0.116270E+09 0.117638E+09
December 0.127382E+09 83513387.45 43868508.89 0.130995E+09 0.143132E+09
           
Annual Sum or Average 0.193619E+10 0.933204E+09 0.100298E+10 0.218574E+10 0.116418E+10
Minimum of Months 0.117100E+09 20784612.80 43868508.89 0.112790E+09 60855736.49
Maximum of Months 0.215815E+09 0.128805E+09 0.118391E+09 0.270161E+09 0.143132E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_WINDOW_6

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.119338E+09 72099289.74 47238653.25 0.112792E+09 0.136631E+09
February 0.166017E+09 0.104399E+09 61617363.50 0.178050E+09 0.111666E+09
March 0.196774E+09 0.107117E+09 89656666.18 0.219259E+09 0.109418E+09
April 0.184604E+09 77781156.68 0.106823E+09 0.212720E+09 88816131.23
May 0.154064E+09 35571110.93 0.118493E+09 0.167755E+09 79785857.03
June 0.128404E+09 20807446.17 0.107597E+09 0.136266E+09 62185435.09
July 0.146057E+09 39250140.65 0.106806E+09 0.175712E+09 60855633.34
August 0.175988E+09 75178869.61 0.100809E+09 0.229086E+09 61541112.80
September 0.215925E+09 0.120722E+09 95202890.38 0.270257E+09 83758113.32
October 0.205582E+09 0.128805E+09 76776924.54 0.238271E+09 0.108380E+09
November 0.117102E+09 68404645.43 48697520.64 0.116272E+09 0.117639E+09
December 0.127384E+09 83513387.45 43870346.81 0.130996E+09 0.143133E+09
           
Annual Sum or Average 0.193724E+10 0.933650E+09 0.100359E+10 0.218744E+10 0.116381E+10
Minimum of Months 0.117102E+09 20807446.17 43870346.81 0.112792E+09 60855633.34
Maximum of Months 0.215925E+09 0.128805E+09 0.118493E+09 0.270257E+09 0.143133E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_1_WALL_SOUTH_DOOR

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 0.168635E+09 0.101012E+09 67622529.32 0.159616E+09 0.190076E+09
February 0.234417E+09 0.146265E+09 88152288.30 0.251566E+09 0.155576E+09
March 0.278512E+09 0.150072E+09 0.128439E+09 0.310306E+09 0.152212E+09
April 0.282644E+09 0.124148E+09 0.158496E+09 0.333858E+09 0.123701E+09
May 0.249270E+09 69481539.59 0.179788E+09 0.287234E+09 0.111070E+09
June 0.210493E+09 47600009.07 0.162893E+09 0.240319E+09 86685554.90
July 0.241590E+09 80719464.87 0.160871E+09 0.305861E+09 85058705.46
August 0.280312E+09 0.130183E+09 0.150129E+09 0.373075E+09 86252553.38
September 0.309457E+09 0.172408E+09 0.137048E+09 0.388207E+09 0.117200E+09
October 0.290124E+09 0.180458E+09 0.109666E+09 0.336072E+09 0.151178E+09
November 0.165626E+09 95835796.38 69790194.72 0.164579E+09 0.163723E+09
December 0.179620E+09 0.117003E+09 62616253.37 0.184483E+09 0.199214E+09
           
Annual Sum or Average 0.289070E+10 0.141519E+10 0.147551E+10 0.333518E+10 0.162195E+10
Minimum of Months 0.165626E+09 47600009.07 62616253.37 0.159616E+09 85058705.46
Maximum of Months 0.309457E+09 0.180458E+09 0.179788E+09 0.388207E+09 0.199214E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 41619917.97 10996767.74 30623150.23 16951428.58 0.140168E+09
February 69323885.10 25334978.91 43988906.19 50071678.68 0.109292E+09
March 0.113952E+09 42028707.04 71923555.30 0.102325E+09 0.100737E+09
April 0.170737E+09 71854030.92 98883202.52 0.181563E+09 79274412.36
May 0.184274E+09 63917099.48 0.120357E+09 0.200104E+09 73774396.33
June 0.214810E+09 93111088.35 0.121699E+09 0.246996E+09 58427461.62
July 0.206717E+09 91663625.21 0.115053E+09 0.246746E+09 54563020.84
August 0.206516E+09 0.103619E+09 0.102897E+09 0.255489E+09 55257458.43
September 0.148619E+09 69396440.26 79222946.47 0.163807E+09 76038046.55
October 0.100285E+09 43504292.48 56780475.91 93334348.38 0.101267E+09
November 47112908.67 13804584.04 33308324.63 26574492.66 0.116398E+09
December 40284547.02 13455851.80 26828695.23 21220028.52 0.144184E+09
           
Annual Sum or Average 0.154425E+10 0.642686E+09 0.901565E+09 0.160518E+10 0.110938E+10
Minimum of Months 40284547.02 10996767.74 26828695.23 16951428.58 54563020.84
Maximum of Months 0.214810E+09 0.103619E+09 0.121699E+09 0.255489E+09 0.144184E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 41617622.32 10996767.74 30620854.58 16950391.04 0.140168E+09
February 69320975.92 25334978.91 43985997.01 50069140.58 0.109291E+09
March 0.113948E+09 42028707.04 71919046.89 0.102321E+09 0.100736E+09
April 0.170732E+09 71854030.92 98877743.88 0.181556E+09 79273861.12
May 0.184267E+09 63917099.48 0.120350E+09 0.200095E+09 73773888.30
June 0.214804E+09 93111088.35 0.121693E+09 0.246989E+09 58426940.30
July 0.206712E+09 91663625.21 0.115048E+09 0.246740E+09 54562135.97
August 0.206511E+09 0.103619E+09 0.102892E+09 0.255484E+09 55256427.73
September 0.148615E+09 69396440.26 79218743.09 0.163803E+09 76037079.09
October 0.100281E+09 43504292.48 56777129.13 93331131.36 0.101267E+09
November 47110415.78 13804584.04 33305831.74 26572795.30 0.116398E+09
December 40282709.10 13455851.80 26826857.31 21219377.17 0.144184E+09
           
Annual Sum or Average 0.154420E+10 0.642686E+09 0.901515E+09 0.160513E+10 0.110937E+10
Minimum of Months 40282709.10 10996767.74 26826857.31 16950391.04 54562135.97
Maximum of Months 0.214804E+09 0.103619E+09 0.121693E+09 0.255484E+09 0.144184E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 41617622.32 10996767.74 30620854.58 16950391.04 0.140168E+09
February 69320975.92 25334978.91 43985997.01 50069140.58 0.109291E+09
March 0.113948E+09 42028707.04 71919046.89 0.102321E+09 0.100736E+09
April 0.170732E+09 71854030.92 98877743.88 0.181556E+09 79273861.12
May 0.184267E+09 63917099.48 0.120350E+09 0.200095E+09 73773888.30
June 0.214804E+09 93111088.35 0.121693E+09 0.246989E+09 58426940.30
July 0.206712E+09 91663625.21 0.115048E+09 0.246740E+09 54562135.97
August 0.206511E+09 0.103619E+09 0.102892E+09 0.255484E+09 55256427.73
September 0.148615E+09 69396440.26 79218743.09 0.163803E+09 76037079.09
October 0.100281E+09 43504292.48 56777129.13 93331131.36 0.101267E+09
November 47110415.78 13804584.04 33305831.74 26572795.30 0.116398E+09
December 40282709.10 13455851.80 26826857.31 21219377.17 0.144184E+09
           
Annual Sum or Average 0.154420E+10 0.642686E+09 0.901515E+09 0.160513E+10 0.110937E+10
Minimum of Months 40282709.10 10996767.74 26826857.31 16950391.04 54562135.97
Maximum of Months 0.214804E+09 0.103619E+09 0.121693E+09 0.255484E+09 0.144184E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_2_WALL_EAST_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 41781746.75 11054836.77 30726909.98 17116046.60 0.140023E+09
February 69472275.25 25393374.36 44078900.89 50318384.73 0.109253E+09
March 0.113992E+09 42047713.21 71944703.11 0.102406E+09 0.100736E+09
April 0.170737E+09 71854030.92 98883202.80 0.181563E+09 79274412.39
May 0.184274E+09 63917099.48 0.120357E+09 0.200104E+09 73774396.36
June 0.214810E+09 93111088.35 0.121699E+09 0.246996E+09 58427461.65
July 0.206717E+09 91663625.21 0.115053E+09 0.246746E+09 54563020.88
August 0.206516E+09 0.103619E+09 0.102897E+09 0.255489E+09 55257458.48
September 0.148631E+09 69399637.66 79231052.54 0.163827E+09 76038046.55
October 0.100399E+09 43555300.85 56843839.83 93560265.71 0.101267E+09
November 47256484.47 13858535.34 33397949.12 26806310.14 0.116353E+09
December 40475707.17 13526285.10 26949422.07 21475319.57 0.144070E+09
           
Annual Sum or Average 0.154506E+10 0.643001E+09 0.902061E+09 0.160641E+10 0.110904E+10
Minimum of Months 40475707.17 11054836.77 26949422.07 17116046.60 54563020.88
Maximum of Months 0.214810E+09 0.103619E+09 0.121699E+09 0.255489E+09 0.144070E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 25399616.94 0.00 25399616.94 1322800.90 0.148177E+09
February 35985322.99 0.00 35985322.99 9686345.88 0.116048E+09
March 58914217.04 0.00 58914217.04 31260842.56 0.103866E+09
April 81257905.81 297143.89 80960761.92 62782230.35 79476433.86
May 0.107839E+09 3198672.35 0.104640E+09 95634703.90 71538691.16
June 0.110213E+09 7182272.47 0.103030E+09 0.104202E+09 55209979.14
July 0.108975E+09 8472072.99 0.100503E+09 0.114484E+09 53233111.71
August 88136376.44 2413594.72 85722781.71 94071000.11 53333724.10
September 65943323.55 20169.10 65923154.45 52768574.94 76441978.99
October 46358698.15 0.00 46358698.15 23120013.95 0.102097E+09
November 27848973.28 0.00 27848973.28 4619051.59 0.120300E+09
December 21685378.60 0.00 21685378.60 959276.72 0.150674E+09
           
Annual Sum or Average 0.778556E+09 21583925.52 0.756972E+09 0.594911E+09 0.113040E+10
Minimum of Months 21685378.60 0.00 21685378.60 959276.72 53233111.71
Maximum of Months 0.110213E+09 8472072.99 0.104640E+09 0.114484E+09 0.150674E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 25397321.17 0.00 25397321.17 1322163.99 0.148177E+09
February 35982413.67 0.00 35982413.67 9684188.90 0.116048E+09
March 58909708.40 0.00 58909708.40 31256615.37 0.103866E+09
April 81207907.12 290049.90 80917857.22 62775653.28 79553623.66
May 0.107678E+09 3149574.40 0.104528E+09 95382869.61 71586740.65
June 0.109948E+09 7072529.35 0.102876E+09 0.103691E+09 55219446.66
July 0.108754E+09 8369168.88 0.100385E+09 0.114054E+09 53254171.13
August 87954416.49 2346785.25 85607631.25 93814963.01 53438337.07
September 65938845.57 20167.64 65918677.92 52764100.65 76441487.59
October 46355351.20 0.00 46355351.20 23116972.46 0.102096E+09
November 27846480.26 0.00 27846480.26 4617660.13 0.120300E+09
December 21683540.59 0.00 21683540.59 958970.06 0.150674E+09
           
Annual Sum or Average 0.777656E+09 21248275.43 0.756408E+09 0.593439E+09 0.113066E+10
Minimum of Months 21683540.59 0.00 21683540.59 958970.06 53254171.13
Maximum of Months 0.109948E+09 8369168.88 0.104528E+09 0.114054E+09 0.150674E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 25397321.17 0.00 25397321.17 1322163.99 0.148177E+09
February 35982413.67 0.00 35982413.67 9684188.90 0.116048E+09
March 58909708.40 0.00 58909708.40 31256615.37 0.103866E+09
April 81186114.64 287306.35 80898808.29 62775649.71 79590807.11
May 0.107678E+09 3149574.40 0.104528E+09 95382869.61 71586740.65
June 0.109948E+09 7072529.35 0.102876E+09 0.103691E+09 55219446.66
July 0.108754E+09 8369131.97 0.100385E+09 0.114054E+09 53254171.13
August 87952953.33 2346555.87 85606397.45 93814575.76 53440408.59
September 65938134.02 20024.46 65918109.56 52764100.65 76442892.22
October 46355351.20 0.00 46355351.20 23116972.46 0.102096E+09
November 27846480.26 0.00 27846480.26 4617660.13 0.120300E+09
December 21683540.59 0.00 21683540.59 958970.06 0.150674E+09
           
Annual Sum or Average 0.777632E+09 21245122.41 0.756387E+09 0.593438E+09 0.113070E+10
Minimum of Months 21683540.59 0.00 21683540.59 958970.06 53254171.13
Maximum of Months 0.109948E+09 8369131.97 0.104528E+09 0.114054E+09 0.150674E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 25397321.17 0.00 25397321.17 1322163.99 0.148177E+09
February 35982413.67 0.00 35982413.67 9684188.90 0.116048E+09
March 58909708.40 0.00 58909708.40 31256615.37 0.103866E+09
April 81186268.79 287324.68 80898944.11 62775878.77 79590777.34
May 0.107678E+09 3149574.40 0.104528E+09 95382869.61 71586740.65
June 0.109948E+09 7072529.35 0.102876E+09 0.103691E+09 55219446.66
July 0.108754E+09 8369131.97 0.100385E+09 0.114054E+09 53254171.13
August 87952627.00 2346566.33 85606060.67 93815302.29 53441612.94
September 65938933.58 19858.85 65919074.74 52764100.65 76441958.74
October 46355351.20 0.00 46355351.20 23116972.46 0.102096E+09
November 27846480.26 0.00 27846480.26 4617660.13 0.120300E+09
December 21683540.59 0.00 21683540.59 958970.06 0.150674E+09
           
Annual Sum or Average 0.777633E+09 21244985.58 0.756388E+09 0.593439E+09 0.113070E+10
Minimum of Months 21683540.59 0.00 21683540.59 958970.06 53254171.13
Maximum of Months 0.109948E+09 8369131.97 0.104528E+09 0.114054E+09 0.150674E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 25397321.17 0.00 25397321.17 1322163.99 0.148177E+09
February 35982413.67 0.00 35982413.67 9684188.90 0.116048E+09
March 58909708.40 0.00 58909708.40 31256615.37 0.103866E+09
April 81210606.96 289973.10 80920633.86 62796440.23 79570733.73
May 0.107678E+09 3149574.40 0.104528E+09 95382869.61 71586740.65
June 0.109948E+09 7072529.35 0.102876E+09 0.103691E+09 55219446.66
July 0.108755E+09 8369219.85 0.100385E+09 0.114054E+09 53254171.13
August 87954114.55 2347119.37 85606995.17 93818726.85 53442027.43
September 65940706.44 19966.15 65920740.29 52764459.50 76439472.81
October 46355351.20 0.00 46355351.20 23116972.46 0.102096E+09
November 27846480.26 0.00 27846480.26 4617660.13 0.120300E+09
December 21683540.59 0.00 21683540.59 958970.06 0.150674E+09
           
Annual Sum or Average 0.777661E+09 21248382.23 0.756412E+09 0.593464E+09 0.113067E+10
Minimum of Months 21683540.59 0.00 21683540.59 958970.06 53254171.13
Maximum of Months 0.109948E+09 8369219.85 0.104528E+09 0.114054E+09 0.150674E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_3_WALL_NORTH_WINDOW_6

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 25399616.82 0.00 25399616.82 1322800.87 0.148177E+09
February 35985322.84 0.00 35985322.84 9686345.77 0.116048E+09
March 58914216.80 0.00 58914216.80 31260842.35 0.103866E+09
April 81260919.45 296097.53 80964821.92 62843871.02 79536409.22
May 0.107932E+09 3240478.98 0.104692E+09 95858147.91 71575262.95
June 0.110201E+09 7165587.60 0.103035E+09 0.104169E+09 55218658.07
July 0.109063E+09 8520491.02 0.100543E+09 0.114684E+09 53249410.52
August 88130031.42 2413356.19 85716675.23 94153007.43 53432449.66
September 65944701.63 19965.05 65924736.58 52768934.24 76440671.37
October 46358697.98 0.00 46358697.98 23120013.79 0.102097E+09
November 27848973.15 0.00 27848973.15 4619051.52 0.120300E+09
December 21685378.51 0.00 21685378.51 959276.71 0.150674E+09
           
Annual Sum or Average 0.778724E+09 21655976.37 0.757068E+09 0.595445E+09 0.113061E+10
Minimum of Months 21685378.51 0.00 21685378.51 959276.71 53249410.52
Maximum of Months 0.110201E+09 8520491.02 0.104692E+09 0.114684E+09 0.150674E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 44181639.80 13585059.67 30596580.13 21662324.97 0.142231E+09
February 71756646.23 27725042.81 44031603.42 55839550.24 0.112172E+09
March 0.110099E+09 37877453.65 72221755.45 99545154.97 0.104350E+09
April 0.161205E+09 62049829.43 99155549.72 0.171231E+09 83644125.84
May 0.212955E+09 87111936.26 0.125843E+09 0.239922E+09 78512156.46
June 0.197736E+09 76233303.18 0.121502E+09 0.225243E+09 61635036.62
July 0.255199E+09 0.134364E+09 0.120836E+09 0.315891E+09 61906662.77
August 0.212774E+09 0.109157E+09 0.103617E+09 0.267831E+09 61350777.65
September 0.168919E+09 81985833.93 86932904.01 0.196053E+09 81442854.78
October 99460403.76 41370835.24 58089568.52 94363886.61 0.105004E+09
November 47632726.89 13987830.61 33644896.28 28420483.52 0.118169E+09
December 41824023.76 14873416.36 26950607.40 25472538.83 0.146519E+09
           
Annual Sum or Average 0.162374E+10 0.700321E+09 0.923421E+09 0.174147E+10 0.115694E+10
Minimum of Months 41824023.76 13585059.67 26950607.40 21662324.97 61350777.65
Maximum of Months 0.255199E+09 0.134364E+09 0.125843E+09 0.315891E+09 0.146519E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 44008210.86 13526993.95 30481216.90 21470361.81 0.142363E+09
February 71625329.45 27668163.70 43957165.74 55603775.94 0.112193E+09
March 0.110050E+09 37857723.63 72192728.15 99454456.34 0.104349E+09
April 0.161200E+09 62049829.43 99150091.08 0.171224E+09 83643723.43
May 0.212948E+09 87111936.26 0.125836E+09 0.239914E+09 78511815.55
June 0.197730E+09 76233303.18 0.121496E+09 0.225236E+09 61634630.31
July 0.255194E+09 0.134364E+09 0.120831E+09 0.315885E+09 61906019.09
August 0.212769E+09 0.109157E+09 0.103612E+09 0.267825E+09 61349858.91
September 0.168901E+09 81979846.31 86921072.37 0.196022E+09 81441917.73
October 99346139.97 41324057.77 58022082.19 94146868.90 0.105005E+09
November 47500020.70 13945478.74 33554541.96 28204542.16 0.118199E+09
December 41660103.02 14815245.07 26844857.96 25245481.45 0.146605E+09
           
Annual Sum or Average 0.162293E+10 0.700033E+09 0.922899E+09 0.174023E+10 0.115720E+10
Minimum of Months 41660103.02 13526993.95 26844857.96 21470361.81 61349858.91
Maximum of Months 0.255194E+09 0.134364E+09 0.125836E+09 0.315885E+09 0.146605E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 44008210.86 13526993.95 30481216.90 21470361.81 0.142363E+09
February 71625329.45 27668163.70 43957165.74 55603775.94 0.112193E+09
March 0.110050E+09 37857723.63 72192728.15 99454456.34 0.104349E+09
April 0.161200E+09 62049829.43 99150091.08 0.171224E+09 83643723.43
May 0.212948E+09 87111936.26 0.125836E+09 0.239914E+09 78511815.55
June 0.197730E+09 76233303.18 0.121496E+09 0.225236E+09 61634630.31
July 0.255194E+09 0.134364E+09 0.120831E+09 0.315885E+09 61906019.09
August 0.212769E+09 0.109157E+09 0.103612E+09 0.267825E+09 61349858.91
September 0.168901E+09 81979846.31 86921072.37 0.196022E+09 81441917.73
October 99346139.97 41324057.77 58022082.19 94146868.90 0.105005E+09
November 47500020.70 13945478.74 33554541.96 28204542.16 0.118199E+09
December 41660103.02 14815245.07 26844857.96 25245481.45 0.146605E+09
           
Annual Sum or Average 0.162293E+10 0.700033E+09 0.922899E+09 0.174023E+10 0.115720E+10
Minimum of Months 41660103.02 13526993.95 26844857.96 21470361.81 61349858.91
Maximum of Months 0.255194E+09 0.134364E+09 0.125836E+09 0.315885E+09 0.146605E+09



Table of Contents

Report: WindowEnergyReportMonthly

For: PERIMETER_ZN_4_WALL_WEST_WINDOW_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SURFACE WINDOW TRANSMITTED SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] SURFACE WINDOW TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] SURFACE WINDOW HEAT GAIN ENERGY [J] SURFACE WINDOW HEAT LOSS ENERGY [J]
January 44010506.62 13526993.95 30483512.67 21471332.67 0.142363E+09
February 71628238.77 27668163.70 43960075.07 55606133.92 0.112193E+09
March 0.110055E+09 37857723.63 72197236.79 99458910.76 0.104350E+09
April 0.161205E+09 62049829.43 99155550.01 0.171231E+09 83644125.86
May 0.212955E+09 87111936.26 0.125843E+09 0.239922E+09 78512156.48
June 0.197736E+09 76233303.18 0.121502E+09 0.225243E+09 61635036.65
July 0.255199E+09 0.134364E+09 0.120836E+09 0.315891E+09 61906662.80
August 0.212774E+09 0.109157E+09 0.103617E+09 0.267831E+09 61350777.70
September 0.168905E+09 81979846.31 86925275.97 0.196027E+09 81442854.83
October 99349486.92 41324057.77 58025429.15 94149968.86 0.105005E+09
November 47502513.72 13945478.74 33557034.98 28206216.81 0.118199E+09
December 41661941.04 14815245.07 26846695.97 25245976.34 0.146605E+09
           
Annual Sum or Average 0.162298E+10 0.700033E+09 0.922949E+09 0.174028E+10 0.115721E+10
Minimum of Months 41661941.04 13526993.95 26846695.97 21471332.67 61350777.70
Maximum of Months 0.255199E+09 0.134364E+09 0.125843E+09 0.315891E+09 0.146605E+09



Table of Contents

Report: WindowZoneSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 312.25 377.03 330.29 199.23 131.07 0.00 0.00
February 545.57 341.25 508.64 319.39 189.25 0.00 0.00
March 607.01 301.93 544.78 295.99 248.79 0.00 0.00
April 620.77 253.72 535.94 227.77 308.17 0.00 0.00
May 482.61 220.20 437.97 105.54 332.43 0.00 0.00
June 407.94 177.39 378.33 66.49 311.84 0.00 0.00
July 507.51 168.08 417.24 117.99 299.25 0.00 0.00
August 651.54 170.08 498.43 216.80 281.63 0.00 0.00
September 775.25 239.34 619.04 345.88 273.16 0.00 0.00
October 659.22 299.22 568.85 355.92 212.93 0.00 0.00
November 332.63 335.47 334.96 195.32 139.65 0.00 0.00
December 362.32 395.01 352.42 230.77 121.65 0.00 0.00
               
Annual Sum or Average 521.73 272.91 460.11 222.45 237.65 0.00 0.00
Minimum of Months 312.25 168.08 330.29 66.49 121.65 0.00 0.00
Maximum of Months 775.25 395.01 619.04 355.92 332.43 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 25.37 209.27 62.22 16.44 45.77 0.00 0.00
February 82.88 180.68 114.68 41.91 72.77 0.00 0.00
March 152.84 150.44 170.19 62.77 107.42 0.00 0.00
April 280.18 122.34 263.48 110.89 152.59 0.00 0.00
May 298.83 110.18 275.20 95.46 179.74 0.00 0.00
June 381.16 90.17 331.49 143.69 187.80 0.00 0.00
July 368.49 81.49 308.71 136.89 171.82 0.00 0.00
August 381.55 82.52 308.41 154.75 153.67 0.00 0.00
September 252.79 117.34 229.35 107.09 122.26 0.00 0.00
October 139.47 151.23 149.81 64.99 84.82 0.00 0.00
November 41.09 179.60 72.76 21.32 51.43 0.00 0.00
December 31.78 215.28 60.23 20.12 40.11 0.00 0.00
               
Annual Sum or Average 203.63 140.70 195.89 81.53 114.37 0.00 0.00
Minimum of Months 25.37 81.49 60.23 16.44 40.11 0.00 0.00
Maximum of Months 381.55 215.28 331.49 154.75 187.80 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 2.96 331.94 56.90 0.00 56.90 0.00 0.00
February 24.02 287.82 89.24 0.00 89.24 0.00 0.00
March 70.02 232.68 131.97 0.00 131.97 0.00 0.00
April 145.35 184.15 188.01 0.67 187.33 0.00 0.00
May 213.93 160.33 241.37 7.11 234.26 0.00 0.00
June 240.41 127.82 254.71 16.45 238.26 0.00 0.00
July 255.89 119.29 243.82 18.84 224.98 0.00 0.00
August 210.37 119.66 197.16 5.31 191.86 0.00 0.00
September 122.14 176.95 152.64 0.05 152.59 0.00 0.00
October 51.79 228.71 103.85 0.00 103.85 0.00 0.00
November 10.69 278.47 64.46 0.00 64.46 0.00 0.00
December 2.15 337.53 48.58 0.00 48.58 0.00 0.00
               
Annual Sum or Average 113.02 215.11 148.02 4.07 143.95 0.00 0.00
Minimum of Months 2.15 119.29 48.58 0.00 48.58 0.00 0.00
Maximum of Months 255.89 337.53 254.71 18.84 238.26 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 32.13 212.55 65.79 20.22 45.57 0.00 0.00
February 92.03 185.49 118.48 45.77 72.71 0.00 0.00
March 148.56 155.84 164.37 56.55 107.83 0.00 0.00
April 264.24 129.08 248.77 95.76 153.01 0.00 0.00
May 358.30 117.25 318.03 130.10 187.93 0.00 0.00
June 347.59 95.12 305.14 117.64 187.50 0.00 0.00
July 471.76 92.45 381.12 200.66 180.46 0.00 0.00
August 399.98 91.62 317.76 163.02 154.74 0.00 0.00
September 302.52 125.68 260.66 126.51 134.14 0.00 0.00
October 140.68 156.82 148.41 61.73 86.68 0.00 0.00
November 43.60 182.39 73.35 21.54 51.82 0.00 0.00
December 37.78 218.90 62.28 22.15 40.13 0.00 0.00
               
Annual Sum or Average 220.77 146.77 205.88 88.80 117.08 0.00 0.00
Minimum of Months 32.13 91.62 62.28 20.22 40.13 0.00 0.00
Maximum of Months 471.76 218.90 381.12 200.66 187.93 0.00 0.00



Table of Contents

Report: WindowZoneSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN RATE [W] ZONE WINDOWS TOTAL HEAT LOSS RATE [W] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION RATE [W] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION RATE [W]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.836342E+09 0.100984E+10 0.884653E+09 0.533608E+09 0.351045E+09 0.00 0.00
February 0.131984E+10 0.825552E+09 0.123050E+10 0.772659E+09 0.457845E+09 0.00 0.00
March 0.162582E+10 0.808690E+09 0.145914E+10 0.792775E+09 0.666361E+09 0.00 0.00
April 0.160904E+10 0.657635E+09 0.138916E+10 0.590385E+09 0.798774E+09 0.00 0.00
May 0.129262E+10 0.589776E+09 0.117305E+10 0.282685E+09 0.890370E+09 0.00 0.00
June 0.105737E+10 0.459785E+09 0.980635E+09 0.172348E+09 0.808287E+09 0.00 0.00
July 0.135930E+10 0.450184E+09 0.111753E+10 0.316029E+09 0.801499E+09 0.00 0.00
August 0.174510E+10 0.455546E+09 0.133499E+10 0.580669E+09 0.754322E+09 0.00 0.00
September 0.200945E+10 0.620366E+09 0.160455E+10 0.896526E+09 0.708029E+09 0.00 0.00
October 0.176566E+10 0.801431E+09 0.152360E+10 0.953290E+09 0.570314E+09 0.00 0.00
November 0.862188E+09 0.869539E+09 0.868229E+09 0.506264E+09 0.361965E+09 0.00 0.00
December 0.970445E+09 0.105800E+10 0.943915E+09 0.618084E+09 0.325831E+09 0.00 0.00
               
Annual Sum or Average 0.164532E+11 0.860635E+10 0.145100E+11 0.701532E+10 0.749464E+10 0.00 0.00
Minimum of Months 0.836342E+09 0.450184E+09 0.868229E+09 0.172348E+09 0.325831E+09 0.00 0.00
Maximum of Months 0.200945E+10 0.105800E+10 0.160455E+10 0.953290E+09 0.890370E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 67945975.10 0.560505E+09 0.166637E+09 44045139.98 0.122592E+09 0.00 0.00
February 0.200505E+09 0.437104E+09 0.277438E+09 0.101398E+09 0.176040E+09 0.00 0.00
March 0.409372E+09 0.402945E+09 0.455840E+09 0.168134E+09 0.287706E+09 0.00 0.00
April 0.726238E+09 0.317097E+09 0.682938E+09 0.287416E+09 0.395522E+09 0.00 0.00
May 0.800398E+09 0.295097E+09 0.737082E+09 0.255668E+09 0.481414E+09 0.00 0.00
June 0.987970E+09 0.233709E+09 0.859227E+09 0.372444E+09 0.486783E+09 0.00 0.00
July 0.986974E+09 0.218250E+09 0.826856E+09 0.366655E+09 0.460202E+09 0.00 0.00
August 0.102195E+10 0.221028E+09 0.826053E+09 0.414476E+09 0.411577E+09 0.00 0.00
September 0.655239E+09 0.304150E+09 0.594480E+09 0.277589E+09 0.316891E+09 0.00 0.00
October 0.373557E+09 0.405067E+09 0.401247E+09 0.174068E+09 0.227179E+09 0.00 0.00
November 0.106512E+09 0.465534E+09 0.188590E+09 55272287.46 0.133318E+09 0.00 0.00
December 85112025.13 0.576599E+09 0.161326E+09 53893840.49 0.107432E+09 0.00 0.00
               
Annual Sum or Average 0.642177E+10 0.443708E+10 0.617772E+10 0.257106E+10 0.360666E+10 0.00 0.00
Minimum of Months 67945975.10 0.218250E+09 0.161326E+09 44045139.98 0.107432E+09 0.00 0.00
Maximum of Months 0.102195E+10 0.576599E+09 0.859227E+09 0.414476E+09 0.486783E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 7934257.74 0.889062E+09 0.152389E+09 0.00 0.152389E+09 0.00 0.00
February 58109447.27 0.696288E+09 0.215900E+09 0.00 0.215900E+09 0.00 0.00
March 0.187548E+09 0.623198E+09 0.353467E+09 0.00 0.353467E+09 0.00 0.00
April 0.376745E+09 0.477314E+09 0.487310E+09 1747895.45 0.485562E+09 0.00 0.00
May 0.572991E+09 0.429428E+09 0.646482E+09 19037448.94 0.627445E+09 0.00 0.00
June 0.623132E+09 0.331304E+09 0.660206E+09 42637977.48 0.617568E+09 0.00 0.00
July 0.685380E+09 0.319495E+09 0.653056E+09 50469216.68 0.602586E+09 0.00 0.00
August 0.563454E+09 0.320495E+09 0.528081E+09 14213977.74 0.513867E+09 0.00 0.00
September 0.316594E+09 0.458648E+09 0.395645E+09 120151.25 0.395524E+09 0.00 0.00
October 0.138708E+09 0.612577E+09 0.278139E+09 0.00 0.278139E+09 0.00 0.00
November 27708743.63 0.721800E+09 0.167084E+09 0.00 0.167084E+09 0.00 0.00
December 5754433.68 0.904046E+09 0.130105E+09 0.00 0.130105E+09 0.00 0.00
               
Annual Sum or Average 0.356406E+10 0.678366E+10 0.466786E+10 0.128227E+09 0.453964E+10 0.00 0.00
Minimum of Months 5754433.68 0.319495E+09 0.130105E+09 0.00 0.130105E+09 0.00 0.00
Maximum of Months 0.685380E+09 0.904046E+09 0.660206E+09 50469216.68 0.627445E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 86058493.38 0.569305E+09 0.176209E+09 54166041.53 0.122043E+09 0.00 0.00
February 0.222639E+09 0.448737E+09 0.286636E+09 0.110730E+09 0.175906E+09 0.00 0.00
March 0.397913E+09 0.417398E+09 0.440255E+09 0.151451E+09 0.288804E+09 0.00 0.00
April 0.684910E+09 0.334576E+09 0.644811E+09 0.248199E+09 0.396611E+09 0.00 0.00
May 0.959672E+09 0.314048E+09 0.851805E+09 0.348448E+09 0.503357E+09 0.00 0.00
June 0.900957E+09 0.246539E+09 0.790930E+09 0.304933E+09 0.485997E+09 0.00 0.00
July 0.126355E+10 0.247625E+09 0.102079E+10 0.537454E+09 0.483333E+09 0.00 0.00
August 0.107131E+10 0.245401E+09 0.851087E+09 0.436628E+09 0.414459E+09 0.00 0.00
September 0.784125E+09 0.325770E+09 0.675626E+09 0.327925E+09 0.347700E+09 0.00 0.00
October 0.376808E+09 0.420018E+09 0.397502E+09 0.165343E+09 0.232159E+09 0.00 0.00
November 0.113021E+09 0.472751E+09 0.190135E+09 55824266.83 0.134311E+09 0.00 0.00
December 0.101188E+09 0.586312E+09 0.166806E+09 59319151.56 0.107487E+09 0.00 0.00
               
Annual Sum or Average 0.696215E+10 0.462848E+10 0.649259E+10 0.280042E+10 0.369217E+10 0.00 0.00
Minimum of Months 86058493.38 0.245401E+09 0.166806E+09 54166041.53 0.107487E+09 0.00 0.00
Maximum of Months 0.126355E+10 0.586312E+09 0.102079E+10 0.537454E+09 0.503357E+09 0.00 0.00



Table of Contents

Report: WindowEnergyZoneSummaryMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE WINDOWS TOTAL HEAT GAIN ENERGY [J] ZONE WINDOWS TOTAL HEAT LOSS ENERGY [J] ZONE WINDOWS TOTAL TRANSMITTED SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J] ZONE EXTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED DIFFUSE SOLAR RADIATION ENERGY [J] ZONE INTERIOR WINDOWS TOTAL TRANSMITTED BEAM SOLAR RADIATION ENERGY [J]
January 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 0.00 0.00
               
Annual Sum or Average 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AverageOutdoorConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE [C] SITE OUTDOOR AIR WETBULB TEMPERATURE [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE [C] SITE WIND SPEED [m/s] SITE SKY TEMPERATURE [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA [W/m2] SITE RAIN STATUS []
January 4.50 3.10 1.22 3.91 -4.2 29.50 44.23 0.00
February 5.82 4.07 1.77 3.94 -3.8 43.80 82.64 0.00
March 8.33 5.86 2.94 3.85 -1.4 65.55 100.60 0.02
April 10.85 8.04 5.25 4.23 1.22 89.73 150.02 0.00
May 12.97 10.02 7.49 3.85 3.75 114.98 168.60 0.00
June 15.59 11.80 8.88 4.02 5.93 107.53 199.74 0.01
July 17.66 13.41 10.38 3.76 8.02 92.25 247.81 0.00
August 18.80 14.57 11.86 3.84 8.90 79.20 215.47 0.01
September 15.09 12.55 10.74 2.23 5.47 68.06 162.11 0.01
October 11.43 9.19 7.19 4.02 2.10 48.18 106.36 0.04
November 8.07 6.72 5.29 3.86 0.13 33.26 46.10 0.00
December 5.42 4.09 2.46 3.51 -3.8 24.03 50.49 0.04
                 
Annual Sum or Average 11.24 8.64 6.31 3.75 1.89 66.43 131.49 0.01
Minimum of Months 4.50 3.10 1.22 2.23 -4.2 24.03 44.23 0.00
Maximum of Months 18.80 14.57 11.86 4.23 8.90 114.98 247.81 0.04



Table of Contents

Report: OutdoorConditionsMaximumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 14.40 11-JAN-14:20 10.49 7.20 8.40 3.89 99.17 130.33
February 20.00 27-FEB-14:00 12.17 5.60 2.60 5.54 87.00 691.00
March 20.60 18-MAR-15:00 10.43 0.00 6.20 6.55 111.50 465.50
April 27.20 27-APR-15:09 17.22 11.02 4.10 12.63 151.33 598.33
May 25.00 05-MAY-15:00 17.36 12.80 2.60 18.99 208.50 29.50
June 26.70 28-JUN-16:00 16.74 10.60 3.10 11.84 131.50 527.00
July 30.60 24-JUL-14:00 18.78 12.20 3.10 20.75 267.00 383.50
August 31.80 10-AUG-16:00 18.70 11.10 2.60 16.85 50.50 750.50
September 25.00 14-SEP-16:00 16.69 11.70 3.10 13.54 100.50 235.00
October 21.70 04-OCT-14:00 11.49 1.70 5.20 4.92 56.50 783.50
November 21.10 04-NOV-13:00 15.94 12.80 0.00 6.95 52.50 729.00
December 13.30 14-DEC-11:00 8.44 3.60 13.90 5.33 127.50 85.00
                 
Annual Sum or Average                
Minimum of Months 13.30   8.44 0.00 0.00 3.89 50.50 29.50
Maximum of Months 31.80   18.78 12.80 13.90 20.75 267.00 783.50



Table of Contents

Report: OutdoorConditionsMinimumDryBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DRYBULB TEMPERATURE {MINIMUM} [C] SITE OUTDOOR AIR DRYBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January -3.9 07-JAN-07:00 -3.9 -3.9 2.10 -14.4 0.00 0.00
February -5.6 19-FEB-05:10 -6.1 -7.3 3.77 -22.8 0.00 0.00
March -0.6 01-MAR-06:00 -2.0 -3.9 1.50 -17.3 16.50 102.00
April 1.70 19-APR-04:00 1.21 0.60 3.10 -11.9 0.00 0.00
May 4.40 11-MAY-02:00 3.92 3.30 3.10 -10.9 0.00 0.00
June 8.30 15-JUN-02:00 7.50 6.70 3.10 -3.2 0.00 0.00
July 11.10 03-JUL-03:00 8.19 5.00 2.60 5.54 0.00 0.00
August 11.00 06-AUG-04:00 10.57 10.20 2.60 -3.2 11.00 135.50
September 7.20 27-SEP-04:49 6.72 6.20 0.25 -4.0 0.00 0.00
October 5.60 13-OCT-04:00 4.51 3.30 2.10 -8.5 0.00 0.00
November 0.00 11-NOV-06:00 -0.2 -0.6 2.10 -16.0 0.00 0.00
December -1.7 26-DEC-06:00 -1.7 -1.7 2.10 -15.7 0.00 0.00
                 
Annual Sum or Average                
Minimum of Months -5.6   -6.1 -7.3 0.25 -22.8 0.00 0.00
Maximum of Months 11.10   10.57 10.20 3.77 5.54 16.50 135.50



Table of Contents

Report: OutdoorConditionsMaximumWetBulbMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR WETBULB TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 10.49 11-JAN-13:00 14.40 7.20 8.20 2.85 105.50 249.00
February 12.42 27-FEB-15:00 19.40 6.70 2.60 6.35 88.00 342.50
March 12.45 09-MAR-11:00 17.20 8.90 2.10 12.41 178.00 40.00
April 17.29 27-APR-14:00 27.20 11.10 4.10 12.41 147.50 646.00
May 17.58 06-MAY-12:00 23.90 13.90 5.20 15.57 365.50 282.50
June 16.74 28-JUN-16:00 26.70 10.60 3.10 11.84 131.50 527.00
July 19.18 31-JUL-15:00 28.90 13.90 4.10 14.65 45.00 848.50
August 20.13 29-AUG-12:00 28.90 15.70 2.60 17.39 136.50 655.00
September 17.97 23-SEP-13:00 23.30 15.00 2.10 9.72 148.00 670.50
October 15.15 01-OCT-11:00 17.20 13.90 4.60 13.73 236.50 63.50
November 16.05 04-NOV-12:00 20.60 13.30 0.00 7.95 62.00 746.50
December 10.71 16-DEC-11:00 11.70 10.00 6.70 7.35 89.50 0.00
                 
Annual Sum or Average                
Minimum of Months 10.49   11.70 6.70 0.00 2.85 45.00 0.00
Maximum of Months 20.13   28.90 15.70 8.20 17.39 365.50 848.50



Table of Contents

Report: OutdoorConditionsMaximumDewPointMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE OUTDOOR AIR DEWPOINT TEMPERATURE {Maximum} [C] SITE OUTDOOR AIR DEWPOINT TEMPERATURE {TIMESTAMP} SITE OUTDOOR AIR DRYBULB TEMPERATURE {AT MAX/MIN} [C] SITE OUTDOOR AIR WETBULB TEMPERATURE {AT MAX/MIN} [C] SITE WIND SPEED {AT MAX/MIN} [m/s] SITE SKY TEMPERATURE {AT MAX/MIN} [C] SITE DIFFUSE SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2] SITE DIRECT SOLAR RADIATION RATE PER AREA {AT MAX/MIN} [W/m2]
January 10.00 11-JAN-21:00 11.10 10.49 4.60 6.75 0.00 0.00
February 11.70 24-FEB-00:00 12.80 12.15 4.10 8.74 0.00 0.00
March 11.70 09-MAR-16:00 12.80 12.15 2.10 8.74 37.50 0.00
April 12.80 28-APR-12:00 16.70 14.35 4.10 8.35 265.50 596.00
May 13.90 05-MAY-16:00 22.80 17.10 2.60 19.17 111.50 27.50
June 13.90 12-JUN-12:00 16.70 15.00 3.60 13.16 263.50 0.00
July 15.00 11-JUL-09:20 16.13 15.49 4.60 12.91 204.17 28.17
August 16.40 30-AUG-07:00 17.40 16.77 5.20 12.41 168.50 34.50
September 15.00 14-SEP-11:20 20.37 16.93 2.10 6.89 152.83 748.17
October 13.90 01-OCT-10:00 16.70 15.01 4.10 13.16 184.50 0.00
November 13.90 03-NOV-19:00 15.00 14.31 4.60 11.46 0.00 0.00
December 10.00 16-DEC-10:00 11.10 10.48 7.70 6.75 81.00 0.00
                 
Annual Sum or Average                
Minimum of Months 10.00   11.10 10.48 2.10 6.75 0.00 0.00
Maximum of Months 16.40   22.80 17.10 7.70 19.17 265.50 748.17



Table of Contents

Report: OutdoorGroundConditionsMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE GROUND TEMPERATURE [C] SITE SURFACE GROUND TEMPERATURE [C] SITE DEEP GROUND TEMPERATURE [C] SITE MAINS WATER TEMPERATURE [C] SITE GROUND REFLECTED SOLAR RADIATION RATE PER AREA [W/m2] SITE SNOW ON GROUND STATUS []
January 18.00 13.00 16.00 11.48 8.35 0.00
February 18.00 13.00 16.00 11.14 14.81 0.00
March 18.00 13.00 16.00 11.69 23.26 0.00
April 18.00 13.00 16.00 12.99 36.00 0.00
May 18.00 13.00 16.00 14.72 45.46 0.00
June 18.00 13.00 16.00 16.40 49.26 0.00
July 18.00 13.00 16.00 17.58 51.50 0.00
August 18.00 13.00 16.00 17.95 42.11 0.00
September 18.00 13.00 16.00 17.39 30.76 0.00
October 18.00 13.00 16.00 16.06 18.91 0.00
November 18.00 13.00 16.00 14.32 9.65 0.00
December 18.00 13.00 16.00 12.65 7.39 0.00
             
Annual Sum or Average 18.00 13.00 16.00 14.55 28.19 0.00
Minimum of Months 18.00 13.00 16.00 11.14 7.39 0.00
Maximum of Months 18.00 13.00 16.00 17.95 51.50 0.00



Table of Contents

Report: WaterHeaterReportMonthly

For: SWHSYS1 WATER HEATER

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY [J] WATER HEATER USE SIDE HEAT TRANSFER ENERGY [J] WATER HEATER BURNER HEATING ENERGY [] WATER HEATER GAS CONSUMPTION [] WATER HEATER TOTAL DEMAND HEAT TRANSFER ENERGY {HOURS NON-ZERO} [HOURS] WATER HEATER LOSS DEMAND ENERGY [] WATER HEATER HEAT LOSS ENERGY [J] WATER HEATER TANK TEMPERATURE [C] WATER HEATER HEAT RECOVERY SUPPLY ENERGY [] WATER HEATER SOURCE ENERGY []
January 0.608626E+09 -483078423.9 0.00 0.00 744.00 0.00 -125547790.8 59.00 0.00 0.00
February 0.551650E+09 -440156666.6 0.00 0.00 672.00 0.00 -111493458.3 58.99 0.00 0.00
March 0.645950E+09 -526621797.8 0.00 0.00 744.00 0.00 -119328326.0 58.99 0.00 0.00
April 0.558250E+09 -445433249.9 0.00 0.00 720.00 0.00 -112816319.8 58.99 0.00 0.00
May 0.585149E+09 -472144548.8 0.00 0.00 744.00 0.00 -113004793.3 58.99 0.00 0.00
June 0.561135E+09 -453353525.1 0.00 0.00 720.00 0.00 -107781093.2 58.99 0.00 0.00
July 0.510671E+09 -400674387.3 0.00 0.00 744.00 0.00 -109997048.2 58.99 0.00 0.00
August 0.567020E+09 -457064188.4 0.00 0.00 744.00 0.00 -109955355.2 58.99 0.00 0.00
September 0.510457E+09 -403103940.2 0.00 0.00 720.00 0.00 -107352760.7 58.99 0.00 0.00
October 0.550997E+09 -436666211.1 0.00 0.00 744.00 0.00 -114331134.3 58.99 0.00 0.00
November 0.569835E+09 -454034798.2 0.00 0.00 720.00 0.00 -115799766.6 59.00 0.00 0.00
December 0.572179E+09 -448402937.2 0.00 0.00 744.00 0.00 -123775857.8 58.99 0.00 0.00
                     
Annual Sum or Average 0.679192E+10 -0.542073E+10 0.00 0.00 8760.00 0.00 -0.137118E+10 58.99 0.00 0.00
Minimum of Months 0.510457E+09 -526621797.8 0.00 0.00 672.00 0.00 -125547790.8 58.99 0.00 0.00
Maximum of Months 0.645950E+09 -400674387.3 0.00 0.00 744.00 0.00 -107352760.7 59.00 0.00 0.00



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_1_DAYLCTRL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 237.83 0.79 0.73 02-JAN-11:30 448.42 21.16 68.00 111.67 784.90 28.03 180.17 99.67
February 259.50 0.77 0.73 01-FEB-08:39 1070.07 25.07 122.67 176.67 1205.93 30.42 234.33 160.33
March 247.00 0.77 0.73 01-MAR-07:40 1755.76 25.57 117.83 215.67 715.50 23.15 207.33 155.50
April 379.50 0.78 0.73 01-APR-08:09 585.93 17.71 0.00 248.50 450.80 22.03 253.00 201.67
May 427.83 0.78 0.73 01-MAY-08:00 514.91 17.54 0.83 259.83 385.54 21.81 271.83 197.17
June 375.17 0.78 0.73 01-JUN-08:00 457.57 17.15 0.00 261.83 343.21 21.42 279.00 171.00
July 471.00 0.80 0.73 01-JUL-11:39 406.74 15.90 0.00 234.00 309.53 20.14 207.50 183.17
August 366.67 0.78 0.73 01-AUG-07:40 509.62 17.02 0.17 254.67 397.18 21.33 242.50 194.67
September 301.17 0.76 0.73 01-SEP-11:39 821.70 19.05 11.83 228.83 567.00 22.87 238.50 190.33
October 245.33 0.76 0.73 01-OCT-11:39 1623.69 25.09 106.67 207.67 767.83 23.34 191.50 171.33
November 242.67 0.79 0.73 01-NOV-11:50 622.85 23.40 99.00 122.17 900.65 28.83 193.67 105.67
December 160.33 0.78 0.73 01-DEC-09:50 606.25 20.53 35.83 95.67 1178.74 32.70 143.83 105.17
                         
Annual Sum or Average 3714.00 0.78     728.30 19.68 562.83 2417.17 592.15 23.74 2643.17 1935.67
Minimum of Months 160.33 0.76 0.73   406.74 15.90 0.00 95.67 309.53 20.14 143.83 99.67
Maximum of Months 471.00 0.80 0.73   1755.76 25.57 122.67 261.83 1205.93 32.70 279.00 201.67



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_2_DAYLCTRL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 237.83 0.85 0.73 03-JAN-09:50 351.94 18.92 65.33 45.00 189.42 20.65 65.33 17.50
February 259.50 0.82 0.73 01-FEB-08:00 571.20 17.90 45.33 89.33 377.38 22.96 117.00 50.00
March 247.00 0.80 0.73 01-MAR-07:49 993.23 18.72 39.17 120.83 361.73 20.88 118.50 78.67
April 379.50 0.80 0.73 01-APR-06:00 433.23 16.00 0.00 177.83 341.52 20.59 166.67 123.50
May 427.83 0.79 0.73 01-MAY-08:50 427.76 16.15 0.00 205.00 337.90 20.83 206.00 143.17
June 375.17 0.79 0.73 01-JUN-05:40 446.22 15.80 0.00 191.00 395.97 22.03 212.33 141.17
July 471.00 0.82 0.73 01-JUL-05:30 365.54 14.55 0.00 174.50 311.30 20.98 183.83 125.17
August 366.67 0.81 0.73 01-AUG-05:00 413.72 15.16 0.00 173.00 349.63 20.23 142.83 121.33
September 301.17 0.80 0.73 01-SEP-08:20 470.18 16.54 7.00 130.67 352.93 21.20 130.83 82.00
October 245.33 0.81 0.73 01-OCT-08:09 1323.90 19.99 62.83 105.67 485.71 22.47 112.00 70.83
November 242.67 0.84 0.73 02-NOV-07:49 502.45 19.11 70.17 49.83 188.20 20.50 61.33 23.00
December 160.33 0.83 0.73 01-DEC-10:09 510.65 21.21 56.83 44.33 171.23 18.98 30.67 12.67
                         
Annual Sum or Average 3714.00 0.81     534.78 16.97 346.67 1507.00 330.76 21.06 1547.33 989.00
Minimum of Months 160.33 0.79 0.73   351.94 14.55 0.00 44.33 171.23 18.98 30.67 12.67
Maximum of Months 471.00 0.85 0.73   1323.90 21.21 70.17 205.00 485.71 22.96 212.33 143.17



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_3_DAYLCTRL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 237.83 0.92 0.84 22-JAN-12:30 121.89 12.22 0.00 0.00 84.76 15.98 0.00 0.00
February 259.50 0.89 0.74 26-FEB-11:30 155.34 13.46 0.00 0.00 109.65 17.35 0.00 0.00
March 247.00 0.85 0.74 26-MAR-11:30 212.99 15.03 0.00 5.50 152.06 18.99 9.67 0.00
April 379.50 0.82 0.74 29-APR-10:30 250.59 15.86 0.00 14.17 175.02 19.69 43.17 0.00
May 427.83 0.79 0.73 01-MAY-12:30 325.48 16.81 1.33 132.67 217.11 21.25 182.67 5.17
June 375.17 0.78 0.73 01-JUN-18:10 331.60 18.24 25.17 126.50 246.05 22.34 207.33 14.50
July 471.00 0.82 0.73 01-JUL-12:00 275.37 17.19 33.83 116.33 185.85 19.40 139.67 0.00
August 366.67 0.82 0.73 01-AUG-08:09 263.82 15.77 0.00 35.33 172.67 19.63 40.33 0.00
September 301.17 0.83 0.74 03-SEP-13:30 235.51 15.82 0.00 6.33 168.76 19.79 15.17 0.00
October 245.33 0.88 0.74 02-OCT-09:30 172.46 13.92 0.00 0.17 125.93 17.94 0.83 0.00
November 242.67 0.91 0.83 02-NOV-10:30 131.15 12.60 0.00 0.00 90.86 16.29 0.00 0.00
December 160.33 0.92 0.83 10-DEC-12:30 115.56 12.03 0.00 0.00 84.78 16.17 0.00 0.00
                         
Annual Sum or Average 3714.00 0.84     234.43 15.40 60.33 437.00 163.17 19.16 638.83 19.67
Minimum of Months 160.33 0.78 0.73   115.56 12.03 0.00 0.00 84.76 15.98 0.00 0.00
Maximum of Months 471.00 0.92 0.84   331.60 18.24 33.83 132.67 246.05 22.34 207.33 14.50



Table of Contents

Report: DaylightingReportMonthly

For: PERIMETER_ZN_4_DAYLCTRL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE EXTERIOR BEAM NORMAL ILLUMINANCE {HOURS NON-ZERO} [HOURS] DAYLIGHTING LIGHTING POWER MULTIPLIER {FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {MIN FOR HOURS SHOWN} [] DAYLIGHTING LIGHTING POWER MULTIPLIER {TIMESTAMP} DAYLIGHTING REFERENCE POINT 1 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 1 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 1 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 ILLUMINANCE {FOR HOURS SHOWN} [lux] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX {FOR HOURS SHOWN} [] DAYLIGHTING REFERENCE POINT 2 GLARE INDEX SETPOINT EXCEEDED TIME [hr] DAYLIGHTING REFERENCE POINT 2 DAYLIGHT ILLUMINANCE SETPOINT EXCEEDED TIME [hr]
January 237.83 0.85 0.73 05-JAN-13:39 338.62 19.11 58.50 43.00 174.32 20.64 56.67 16.00
February 259.50 0.82 0.73 01-FEB-13:09 582.15 18.26 45.17 82.00 349.97 22.90 112.17 50.50
March 247.00 0.80 0.73 01-MAR-13:09 896.28 18.94 39.33 114.17 571.86 23.09 120.83 84.00
April 379.50 0.80 0.73 01-APR-12:30 426.41 16.22 0.00 175.17 331.04 20.67 176.83 118.83
May 427.83 0.79 0.73 01-MAY-11:39 460.76 16.43 0.17 218.67 371.68 21.00 223.67 152.00
June 375.17 0.80 0.73 01-JUN-13:09 433.22 16.06 0.00 193.83 398.05 20.83 201.83 139.83
July 471.00 0.81 0.73 01-JUL-12:09 413.77 14.74 0.00 202.50 351.15 19.52 170.50 160.50
August 366.67 0.80 0.73 02-AUG-10:30 433.52 15.42 0.00 180.67 366.83 20.32 158.33 132.67
September 301.17 0.79 0.73 01-SEP-12:09 663.33 17.25 8.50 155.00 457.43 21.77 160.33 117.50
October 245.33 0.81 0.73 01-OCT-12:09 1239.85 20.55 66.83 112.67 461.18 23.17 128.50 75.17
November 242.67 0.84 0.73 02-NOV-12:50 479.51 19.16 67.50 51.83 180.74 19.99 56.17 19.17
December 160.33 0.84 0.73 01-DEC-13:09 537.86 20.13 47.33 41.00 168.53 18.82 34.50 13.00
                         
Annual Sum or Average 3714.00 0.81     547.89 17.20 333.33 1570.50 357.89 20.99 1600.33 1079.17
Minimum of Months 160.33 0.79 0.73   338.62 14.74 0.00 41.00 168.53 18.82 34.50 13.00
Maximum of Months 471.00 0.85 0.73   1239.85 20.55 67.50 218.67 571.86 23.17 223.67 160.50



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1 HEATING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.662980E+09 5039.57 11-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.290246E+09 4979.11 01-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 31748417.78 4566.21 06-MAR-06:01 0.00 0.00 0.00 0.00 0.00
April 2211181.29 595.96 18-APR-06:20 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 77649882.36 5316.54 27-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.320911E+09 4964.06 28-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.138575E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.662980E+09 5316.54   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2 HEATING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.164946E+10 7057.29 11-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.908633E+09 7935.33 24-FEB-06:02 0.00 0.00 0.00 0.00 0.00
March 0.438116E+09 7224.68 09-MAR-06:02 0.00 0.00 0.00 0.00 0.00
April 0.219032E+09 6825.74 10-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 31860362.83 2057.33 18-MAY-06:10 0.00 0.00 0.00 0.00 0.00
June 722226.09 289.66 15-JUN-06:20 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 1407440.85 676.73 28-SEP-06:30 0.00 0.00 0.00 0.00 0.00
October 42879871.73 4483.33 23-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.520026E+09 7445.15 27-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.112524E+10 7057.29 29-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.493738E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.164946E+10 7935.33   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3 HEATING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.100184E+10 4102.80 11-JAN-06:02 0.00 0.00 0.00 0.00 0.00
February 0.612946E+09 4613.25 24-FEB-06:02 0.00 0.00 0.00 0.00 0.00
March 0.262930E+09 4200.11 09-MAR-06:02 0.00 0.00 0.00 0.00 0.00
April 84736376.91 3968.18 10-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 2328121.81 2322.70 30-MAY-05:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 17379000.58 4189.70 23-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.277236E+09 4328.28 27-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.671872E+09 4102.80 29-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.293127E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.100184E+10 4613.25   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4 HEATING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.181639E+10 4228.11 11-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 0.125454E+10 4754.16 24-FEB-06:02 0.00 0.00 0.00 0.00 0.00
March 0.691613E+09 4395.25 10-MAR-06:03 0.00 0.00 0.00 0.00 0.00
April 0.259087E+09 4317.67 03-APR-05:02 0.00 0.00 0.00 0.00 0.00
May 5956588.96 2953.36 30-MAY-05:03 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 54829265.11 4317.67 23-OCT-05:03 0.00 0.00 0.00 0.00 0.00
November 0.612128E+09 4460.48 27-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.130303E+10 4228.11 29-DEC-06:03 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.599757E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.181639E+10 4754.16   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5 HEATING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.100304E+10 4917.87 11-JAN-06:02 0.00 0.00 0.00 0.00 0.00
February 0.622699E+09 5529.74 24-FEB-06:02 0.00 0.00 0.00 0.00 0.00
March 0.266131E+09 5034.52 09-MAR-06:02 0.00 0.00 0.00 0.00 0.00
April 89544942.80 4756.51 10-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 184172.33 237.45 18-MAY-05:05 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 12589003.19 4659.31 31-OCT-05:02 0.00 0.00 0.00 0.00 0.00
November 0.271814E+09 5188.15 27-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 0.659850E+09 4917.87 29-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.292585E+10     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.100304E+10 5529.74   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1_SUPPHEATCOIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 12748354.79 3406.87 05-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 9361034.55 3406.87 14-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 106205.63 1770.09 27-MAR-05:01 0.00 0.00 0.00 0.00 0.00
April 0.00 0.00 01-APR-00:10 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 434036.11 2454.58 24-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 13835366.06 3406.87 12-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 36484997.14     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 13835366.06 3406.87   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2_SUPPHEATCOIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 46662291.92 4463.50 05-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 26464495.49 4463.50 06-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 3195350.22 4463.50 01-MAR-06:01 0.00 0.00 0.00 0.00 0.00
April 1937204.20 4297.82 19-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 4410791.11 4463.50 24-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 43060151.34 4463.50 06-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.125730E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 46662291.92 4463.50   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3_SUPPHEATCOIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 24420622.72 2766.65 05-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 17647620.74 2766.65 06-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 3906303.14 2766.65 01-MAR-06:01 0.00 0.00 0.00 0.00 0.00
April 1476114.01 2694.56 19-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 2384189.37 2766.65 13-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 22100960.48 2766.65 05-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 71935810.46     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 24420622.72 2766.65   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4_SUPPHEATCOIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 0.106968E+09 4276.23 09-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 94102826.43 4025.36 14-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 10413326.03 3390.23 02-MAR-06:01 0.00 0.00 0.00 0.00 0.00
April 3258524.58 2639.42 19-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 12110917.95 2947.39 13-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 86975501.65 4400.74 26-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.313829E+09     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.106968E+09 4400.74   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5_SUPPHEATCOIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [J] HEATING COIL HEATING RATE {Maximum} [W] HEATING COIL HEATING RATE {TIMESTAMP} COOLING COIL TOTAL COOLING ENERGY [] COOLING COIL SENSIBLE COOLING ENERGY [] COOLING COIL TOTAL COOLING RATE [] COOLING COIL SENSIBLE COOLING RATE [] COOLING COIL WETTED AREA FRACTION []
January 14637338.20 2758.94 05-JAN-06:01 0.00 0.00 0.00 0.00 0.00
February 10633107.05 2758.94 06-FEB-06:01 0.00 0.00 0.00 0.00 0.00
March 3390653.96 2758.94 01-MAR-06:01 0.00 0.00 0.00 0.00 0.00
April 1481117.45 2758.94 18-APR-05:01 0.00 0.00 0.00 0.00 0.00
May 0.00 0.00 01-MAY-00:10 0.00 0.00 0.00 0.00 0.00
June 0.00 0.00 01-JUN-00:10 0.00 0.00 0.00 0.00 0.00
July 0.00 0.00 01-JUL-00:10 0.00 0.00 0.00 0.00 0.00
August 0.00 0.00 01-AUG-00:10 0.00 0.00 0.00 0.00 0.00
September 0.00 0.00 01-SEP-00:10 0.00 0.00 0.00 0.00 0.00
October 0.00 0.00 01-OCT-00:10 0.00 0.00 0.00 0.00 0.00
November 1775233.63 2758.94 13-NOV-06:01 0.00 0.00 0.00 0.00 0.00
December 14083106.29 2758.94 01-DEC-06:01 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 46000556.58     0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.00 0.00   0.00 0.00 0.00 0.00 0.00
Maximum of Months 14637338.20 2758.94   0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:1 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00
March 0.00 0.00 9985309.73 7974685.19 553.08 10-MAR-15:23 420.25 0.00
April 0.00 0.00 0.282498E+09 0.240022E+09 5011.42 28-APR-05:03 4018.25 0.00
May 0.00 0.00 0.108819E+10 0.903296E+09 5082.36 08-MAY-05:03 3798.58 0.00
June 0.00 0.00 0.174692E+10 0.147428E+10 5103.43 13-JUN-05:03 3738.52 0.00
July 0.00 0.00 0.230192E+10 0.190920E+10 5125.59 28-JUL-05:02 3942.30 0.00
August 0.00 0.00 0.298184E+10 0.242950E+10 5114.43 10-AUG-05:02 4082.03 0.00
September 0.00 0.00 0.175550E+10 0.140349E+10 5105.13 26-SEP-05:03 3702.80 0.00
October 0.00 0.00 0.590062E+09 0.503409E+09 4969.16 06-OCT-05:03 4224.49 0.00
November 0.00 0.00 81960912.47 59854788.55 1033.25 03-NOV-16:00 689.63 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.108389E+11 0.893104E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.298184E+10 0.242950E+10 5125.59   4224.49 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:2 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 19540433.83 19500559.35 1402.50 27-FEB-15:00 1402.50 0.00
March 0.00 0.00 83127012.42 82873921.40 1568.16 02-MAR-14:25 1568.16 0.00
April 0.00 0.00 0.286930E+09 0.275225E+09 3955.65 27-APR-14:30 3734.19 0.00
May 0.00 0.00 0.530036E+09 0.492615E+09 3011.24 04-MAY-14:00 2816.51 0.00
June 0.00 0.00 0.921572E+09 0.854297E+09 3244.75 28-JUN-14:05 3077.30 0.00
July 0.00 0.00 0.163590E+10 0.146347E+10 6938.19 31-JUL-05:02 6297.65 0.00
August 0.00 0.00 0.255238E+10 0.225030E+10 6997.24 25-AUG-05:02 6021.20 0.00
September 0.00 0.00 0.161686E+10 0.144702E+10 6936.84 14-SEP-05:02 6264.24 0.00
October 0.00 0.00 0.623543E+09 0.610275E+09 4812.34 04-OCT-14:00 4812.34 0.00
November 0.00 0.00 20758440.00 19369690.34 1067.23 02-NOV-13:30 952.22 0.00
December 0.00 0.00 5637787.05 5637787.05 708.06 05-DEC-14:30 708.06 0.00
                 
Annual Sum or Average 0.00 0.00 0.829628E+10 0.752059E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.255238E+10 0.225030E+10 6997.24   6297.65 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:3 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 0.00 0.00
April 0.00 0.00 94592788.73 90766645.65 3487.63 28-APR-12:02 2983.79 0.00
May 0.00 0.00 0.295108E+09 0.277069E+09 3595.27 15-MAY-10:02 3588.10 0.00
June 0.00 0.00 0.702407E+09 0.660215E+09 3724.79 28-JUN-10:02 3615.47 0.00
July 0.00 0.00 0.100644E+10 0.922858E+09 4027.71 31-JUL-05:02 3608.11 0.00
August 0.00 0.00 0.139230E+10 0.125323E+10 4062.49 25-AUG-05:02 3452.67 0.00
September 0.00 0.00 0.650702E+09 0.582851E+09 3942.46 14-SEP-10:02 3566.54 0.00
October 0.00 0.00 0.132414E+09 0.129116E+09 2800.93 04-OCT-10:02 2800.93 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.427397E+10 0.391611E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.139230E+10 0.125323E+10 4062.49   3615.47 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:4 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 0.00 0.00 0.00 01-FEB-00:10 0.00 0.00
March 0.00 0.00 0.00 0.00 0.00 01-MAR-00:10 0.00 0.00
April 0.00 0.00 47345308.75 42801063.66 1656.62 27-APR-15:58 1519.00 0.00
May 0.00 0.00 0.236290E+09 0.210552E+09 1981.92 05-MAY-15:50 1702.30 0.00
June 0.00 0.00 0.704087E+09 0.635946E+09 2397.40 28-JUN-16:00 2266.63 0.00
July 0.00 0.00 0.121246E+10 0.106046E+10 4135.26 25-JUL-05:02 3620.39 0.00
August 0.00 0.00 0.162863E+10 0.139376E+10 4180.18 25-AUG-05:02 3485.07 0.00
September 0.00 0.00 0.648633E+09 0.543892E+09 2479.07 14-SEP-15:43 2127.35 0.00
October 0.00 0.00 74170918.55 71270366.80 1195.66 04-OCT-15:10 1195.66 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.455162E+10 0.395869E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.162863E+10 0.139376E+10 4180.18   3620.39 0.00



Table of Contents

Report: CoilReportMonthly

For: PSZ-AC:5 HP COOLING COIL

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

HEATING COIL HEATING ENERGY [] HEATING COIL HEATING RATE [] COOLING COIL TOTAL COOLING ENERGY [J] COOLING COIL SENSIBLE COOLING ENERGY [J] COOLING COIL TOTAL COOLING RATE {Maximum} [W] COOLING COIL TOTAL COOLING RATE {TIMESTAMP} COOLING COIL SENSIBLE COOLING RATE {AT MAX/MIN} [W] COOLING COIL WETTED AREA FRACTION []
January 0.00 0.00 0.00 0.00 0.00 01-JAN-00:10 0.00 0.00
February 0.00 0.00 76367.91 75616.33 71.76 27-FEB-15:57 71.09 0.00
March 0.00 0.00 3934244.10 3928849.38 400.55 02-MAR-16:35 400.55 0.00
April 0.00 0.00 0.108420E+09 0.101709E+09 2226.75 27-APR-15:53 2071.92 0.00
May 0.00 0.00 0.383484E+09 0.353808E+09 2322.51 15-MAY-15:57 2322.51 0.00
June 0.00 0.00 0.718710E+09 0.664729E+09 3232.61 23-JUN-05:02 3091.25 0.00
July 0.00 0.00 0.115592E+10 0.104159E+10 4846.07 31-JUL-05:02 4438.25 0.00
August 0.00 0.00 0.147941E+10 0.130560E+10 4881.73 25-AUG-05:02 4239.92 0.00
September 0.00 0.00 0.769720E+09 0.677595E+09 4809.60 14-SEP-05:02 4314.96 0.00
October 0.00 0.00 0.168648E+09 0.163624E+09 2072.30 04-OCT-15:57 2072.30 0.00
November 0.00 0.00 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00
December 0.00 0.00 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00
                 
Annual Sum or Average 0.00 0.00 0.478833E+10 0.431266E+10       0.00
Minimum of Months 0.00 0.00 0.00 0.00 0.00   0.00 0.00
Maximum of Months 0.00 0.00 0.147941E+10 0.130560E+10 4881.73   4438.25 0.00



Table of Contents

Report: PlantLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 268.46 639.75 31-JAN-12:20
February 0.00 0.00 01-FEB-00:10 114.37 640.76 10-FEB-12:15
March 0.00 0.00 01-MAR-00:10 0.00 0.00 01-MAR-00:10
April 0.00 0.00 01-APR-00:10 0.00 0.00 01-APR-00:10
May 0.00 0.00 01-MAY-00:10 0.00 0.00 01-MAY-00:10
June 0.00 0.00 01-JUN-00:10 0.00 0.00 01-JUN-00:10
July 0.00 0.00 01-JUL-00:10 0.00 0.00 01-JUL-00:10
August 0.00 0.00 01-AUG-00:10 0.00 0.00 01-AUG-00:10
September 0.00 0.00 01-SEP-00:10 0.00 0.00 01-SEP-00:10
October 0.00 0.00 01-OCT-00:10 0.00 0.00 01-OCT-00:10
November 0.00 0.00 01-NOV-00:10 0.00 0.00 01-NOV-00:10
December 0.00 0.00 01-DEC-00:10 0.00 0.00 01-DEC-00:10
             
Annual Sum or Average 0.00     31.57    
Minimum of Months 0.00 0.00   0.00 0.00  
Maximum of Months 0.00 0.00   268.46 640.76  



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:1 FAN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.307993E+09 0.34 313.38 02-JAN-06:01 0.93
February 0.278660E+09 0.34 313.38 01-FEB-06:01 0.92
March 0.337326E+09 0.37 313.38 01-MAR-06:01 0.92
April 0.293327E+09 0.33 313.38 03-APR-05:02 0.92
May 0.322659E+09 0.36 313.38 01-MAY-05:10 0.92
June 0.322659E+09 0.37 313.38 01-JUN-05:10 0.92
July 0.293327E+09 0.32 313.38 03-JUL-05:03 0.92
August 0.337326E+09 0.37 313.38 01-AUG-05:02 0.92
September 0.293327E+09 0.33 313.38 01-SEP-05:02 0.92
October 0.307993E+09 0.34 313.38 02-OCT-05:10 0.92
November 0.307993E+09 0.35 313.38 01-NOV-05:03 0.92
December 0.293327E+09 0.32 313.38 01-DEC-06:01 0.93
           
Annual Sum or Average 0.369591E+10 0.35      
Minimum of Months 0.278660E+09 0.32 313.38   0.92
Maximum of Months 0.337326E+09 0.37 313.38   0.93



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:2 FAN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.451635E+09 0.37 453.40 02-JAN-06:01 0.93
February 0.403162E+09 0.34 453.40 01-FEB-06:01 0.93
March 0.488039E+09 0.37 453.40 01-MAR-06:01 0.93
April 0.424382E+09 0.34 453.40 03-APR-05:02 0.93
May 0.466820E+09 0.36 453.40 01-MAY-05:10 0.93
June 0.466820E+09 0.37 453.40 01-JUN-05:10 0.93
July 0.424382E+09 0.32 453.40 03-JUL-05:03 0.93
August 0.488039E+09 0.37 453.40 01-AUG-05:02 0.92
September 0.424382E+09 0.33 453.40 01-SEP-05:02 0.92
October 0.445601E+09 0.34 453.40 02-OCT-05:10 0.93
November 0.445601E+09 0.35 453.40 01-NOV-05:03 0.93
December 0.424630E+09 0.33 453.40 01-DEC-06:01 0.93
           
Annual Sum or Average 0.535349E+10 0.35      
Minimum of Months 0.403162E+09 0.32 453.40   0.92
Maximum of Months 0.488039E+09 0.37 453.40   0.93



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:3 FAN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.213317E+09 0.38 263.59 02-JAN-06:01 0.93
February 0.187222E+09 0.33 263.59 01-FEB-06:01 0.93
March 0.218487E+09 0.29 263.59 01-MAR-06:01 0.93
April 0.190775E+09 0.27 263.59 03-APR-05:02 0.93
May 0.212163E+09 0.32 263.59 01-MAY-05:10 0.93
June 0.218992E+09 0.37 263.59 01-JUN-05:10 0.93
July 0.204342E+09 0.33 263.59 03-JUL-05:03 0.93
August 0.238557E+09 0.38 263.59 01-AUG-05:02 0.92
September 0.199061E+09 0.32 263.59 01-SEP-05:02 0.92
October 0.200992E+09 0.28 263.59 02-OCT-05:10 0.93
November 0.199647E+09 0.28 263.59 01-NOV-05:03 0.93
December 0.195069E+09 0.29 263.59 01-DEC-06:01 0.93
           
Annual Sum or Average 0.247862E+10 0.32      
Minimum of Months 0.187222E+09 0.27 263.59   0.92
Maximum of Months 0.238557E+09 0.38 263.59   0.93



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:4 FAN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.273371E+09 0.39 266.36 02-JAN-06:01 0.93
February 0.244064E+09 0.37 266.36 01-FEB-06:01 0.93
March 0.286711E+09 0.37 266.36 01-MAR-06:01 0.93
April 0.249314E+09 0.34 266.36 03-APR-05:02 0.93
May 0.274245E+09 0.36 266.36 01-MAY-05:10 0.93
June 0.274245E+09 0.37 266.36 01-JUN-05:10 0.93
July 0.249314E+09 0.32 266.36 03-JUL-05:03 0.93
August 0.286711E+09 0.37 266.36 01-AUG-05:02 0.92
September 0.249314E+09 0.33 266.36 01-SEP-05:02 0.92
October 0.261780E+09 0.34 266.36 02-OCT-05:10 0.93
November 0.261780E+09 0.35 266.36 01-NOV-05:03 0.93
December 0.251312E+09 0.33 266.36 01-DEC-06:01 0.93
           
Annual Sum or Average 0.316216E+10 0.35      
Minimum of Months 0.244064E+09 0.32 266.36   0.92
Maximum of Months 0.286711E+09 0.39 266.36   0.93



Table of Contents

Report: FanReportMonthly

For: PSZ-AC:5 FAN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

FAN ELECTRICITY ENERGY [J] FAN RISE IN AIR TEMPERATURE [deltaC] FAN ELECTRICITY RATE {Maximum} [W] FAN ELECTRICITY RATE {TIMESTAMP} FAN RISE IN AIR TEMPERATURE {AT MAX/MIN} [deltaC]
January 0.317863E+09 0.39 315.95 02-JAN-06:01 0.93
February 0.284705E+09 0.37 315.95 01-FEB-06:01 0.93
March 0.340090E+09 0.37 315.95 01-MAR-06:01 0.93
April 0.295730E+09 0.34 315.95 03-APR-05:02 0.93
May 0.325303E+09 0.36 315.95 01-MAY-05:10 0.93
June 0.325303E+09 0.37 315.95 01-JUN-05:10 0.93
July 0.295730E+09 0.32 315.95 03-JUL-05:03 0.93
August 0.340090E+09 0.37 315.95 01-AUG-05:02 0.92
September 0.295730E+09 0.33 315.95 01-SEP-05:02 0.92
October 0.310517E+09 0.34 315.95 02-OCT-05:10 0.93
November 0.310517E+09 0.35 315.95 01-NOV-05:03 0.93
December 0.297143E+09 0.33 315.95 01-DEC-06:01 0.93
           
Annual Sum or Average 0.373872E+10 0.35      
Minimum of Months 0.284705E+09 0.32 315.95   0.92
Maximum of Months 0.340090E+09 0.39 315.95   0.93



Table of Contents

Report: PumpReportMonthly

For: SWHSYS1 PUMP

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PUMP ELECTRICITY ENERGY [J] PUMP FLUID HEAT GAIN ENERGY [J] PUMP ELECTRICITY RATE {Maximum} [W] PUMP ELECTRICITY RATE {TIMESTAMP} PUMP SHAFT POWER {AT MAX/MIN} [W] PUMP FLUID HEAT GAIN RATE {AT MAX/MIN} [W] PUMP OUTLET TEMPERATURE {AT MAX/MIN} [C] PUMP MASS FLOW RATE {AT MAX/MIN} [kg/s]
January 0.02 0.01 0.00 02-JAN-07:05 0.00 0.00 35.37 0.00
February 0.01 0.00 0.00 01-FEB-07:10 0.00 0.00 11.16 0.00
March 0.00 0.00 0.00 01-MAR-00:10 0.00 0.00 11.10 0.00
April 0.00 0.00 0.00 01-APR-00:10 0.00 0.00 11.10 0.00
May 0.00 0.00 0.00 01-MAY-00:10 0.00 0.00 11.10 0.00
June 0.00 0.00 0.00 01-JUN-00:10 0.00 0.00 11.10 0.00
July 0.00 0.00 0.00 01-JUL-00:10 0.00 0.00 11.10 0.00
August 0.00 0.00 0.00 01-AUG-00:10 0.00 0.00 11.10 0.00
September 0.00 0.00 0.00 01-SEP-00:10 0.00 0.00 11.10 0.00
October 0.00 0.00 0.00 01-OCT-00:10 0.00 0.00 11.10 0.00
November 0.00 0.00 0.00 01-NOV-00:10 0.00 0.00 11.10 0.00
December 0.00 0.00 0.00 01-DEC-00:10 0.00 0.00 11.10 0.00
                 
Annual Sum or Average 0.03 0.01            
Minimum of Months 0.00 0.00 0.00   0.00 0.00 11.10 0.00
Maximum of Months 0.02 0.01 0.00   0.00 0.00 35.37 0.00



Table of Contents

Report: CondLoopDemandReportMonthly

For: SWHSYS1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

PLANT SUPPLY SIDE COOLING DEMAND RATE [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE COOLING DEMAND RATE {TIMESTAMP} PLANT SUPPLY SIDE INLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE OUTLET TEMPERATURE {AT MAX/MIN} [C] PLANT SUPPLY SIDE HEATING DEMAND RATE [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {Maximum} [W] PLANT SUPPLY SIDE HEATING DEMAND RATE {TIMESTAMP}
January 0.00 0.00 01-JAN-00:10 48.89 48.89 268.46 639.75 31-JAN-12:20
February 0.00 0.00 01-FEB-00:10 11.16 11.16 114.37 640.76 10-FEB-12:15
March 0.00 0.00 01-MAR-00:10 11.10 11.10 0.00 0.00 01-MAR-00:10
April 0.00 0.00 01-APR-00:10 11.10 11.10 0.00 0.00 01-APR-00:10
May 0.00 0.00 01-MAY-00:10 11.10 11.10 0.00 0.00 01-MAY-00:10
June 0.00 0.00 01-JUN-00:10 11.10 11.10 0.00 0.00 01-JUN-00:10
July 0.00 0.00 01-JUL-00:10 11.10 11.10 0.00 0.00 01-JUL-00:10
August 0.00 0.00 01-AUG-00:10 11.10 11.10 0.00 0.00 01-AUG-00:10
September 0.00 0.00 01-SEP-00:10 11.10 11.10 0.00 0.00 01-SEP-00:10
October 0.00 0.00 01-OCT-00:10 11.10 11.10 0.00 0.00 01-OCT-00:10
November 0.00 0.00 01-NOV-00:10 11.10 11.10 0.00 0.00 01-NOV-00:10
December 0.00 0.00 01-DEC-00:10 11.10 11.10 0.00 0.00 01-DEC-00:10
                 
Annual Sum or Average 0.00         31.57    
Minimum of Months 0.00 0.00   11.10 11.10 0.00 0.00  
Maximum of Months 0.00 0.00   48.89 48.89 268.46 640.76  



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT {FOR HOURS SHOWN} []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00  
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: ZoneTemperatureOscillationReportMonthly

For: ATTIC

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE OSCILLATING TEMPERATURES TIME {HOURS NON-ZERO} [HOURS] ZONE PEOPLE OCCUPANT COUNT []
January 0.00 0.00
February 0.00 0.00
March 0.00 0.00
April 0.00 0.00
May 0.00 0.00
June 0.00 0.00
July 0.00 0.00
August 0.00 0.00
September 0.00 0.00
October 0.00 0.00
November 0.00 0.00
December 0.00 0.00
     
Annual Sum or Average 0.00 0.00
Minimum of Months 0.00 0.00
Maximum of Months 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.563880E+09 0.00 0.00
February 0.00 0.00 0.00 0.408137E+09 0.00 0.00
March 0.00 0.00 0.00 0.354887E+09 0.00 0.00
April 0.00 0.00 0.00 0.358640E+09 0.00 0.00
May 0.00 0.00 0.00 0.561060E+09 0.00 0.00
June 0.00 0.00 0.00 0.698681E+09 0.00 0.00
July 0.00 0.00 0.00 0.781687E+09 0.00 0.00
August 0.00 0.00 0.00 0.972264E+09 0.00 0.00
September 0.00 0.00 0.00 0.667305E+09 0.00 0.00
October 0.00 0.00 0.00 0.438081E+09 0.00 0.00
November 0.00 0.00 0.00 0.359748E+09 0.00 0.00
December 0.00 0.00 0.00 0.434842E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.659921E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.354887E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.972264E+09 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.106655E+10 0.00 0.00
February 0.00 0.00 0.00 0.770448E+09 0.00 0.00
March 0.00 0.00 0.00 0.663156E+09 0.00 0.00
April 0.00 0.00 0.00 0.565806E+09 0.00 0.00
May 0.00 0.00 0.00 0.596314E+09 0.00 0.00
June 0.00 0.00 0.00 0.672871E+09 0.00 0.00
July 0.00 0.00 0.00 0.787056E+09 0.00 0.00
August 0.00 0.00 0.00 0.105412E+10 0.00 0.00
September 0.00 0.00 0.00 0.770984E+09 0.00 0.00
October 0.00 0.00 0.00 0.595458E+09 0.00 0.00
November 0.00 0.00 0.00 0.640334E+09 0.00 0.00
December 0.00 0.00 0.00 0.861838E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.904494E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.565806E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.106655E+10 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.596606E+09 0.00 0.00
February 0.00 0.00 0.00 0.438393E+09 0.00 0.00
March 0.00 0.00 0.00 0.313864E+09 0.00 0.00
April 0.00 0.00 0.00 0.243113E+09 0.00 0.00
May 0.00 0.00 0.00 0.279017E+09 0.00 0.00
June 0.00 0.00 0.00 0.374512E+09 0.00 0.00
July 0.00 0.00 0.00 0.426425E+09 0.00 0.00
August 0.00 0.00 0.00 0.547872E+09 0.00 0.00
September 0.00 0.00 0.00 0.341617E+09 0.00 0.00
October 0.00 0.00 0.00 0.236447E+09 0.00 0.00
November 0.00 0.00 0.00 0.303080E+09 0.00 0.00
December 0.00 0.00 0.00 0.462026E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.456297E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.236447E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.596606E+09 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.930085E+09 0.00 0.00
February 0.00 0.00 0.00 0.719242E+09 0.00 0.00
March 0.00 0.00 0.00 0.524686E+09 0.00 0.00
April 0.00 0.00 0.00 0.349310E+09 0.00 0.00
May 0.00 0.00 0.00 0.329228E+09 0.00 0.00
June 0.00 0.00 0.00 0.429880E+09 0.00 0.00
July 0.00 0.00 0.00 0.514635E+09 0.00 0.00
August 0.00 0.00 0.00 0.646085E+09 0.00 0.00
September 0.00 0.00 0.00 0.391650E+09 0.00 0.00
October 0.00 0.00 0.00 0.296797E+09 0.00 0.00
November 0.00 0.00 0.00 0.478203E+09 0.00 0.00
December 0.00 0.00 0.00 0.733342E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.634314E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.296797E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.930085E+09 0.00 0.00



Table of Contents

Report: AirLoopSystemEnergyAndWaterUseMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM HOT WATER ENERGY [J] AIR SYSTEM STEAM ENERGY [J] AIR SYSTEM CHILLED WATER ENERGY [J] AIR SYSTEM ELECTRICITY ENERGY [J] AIR SYSTEM NATURAL GAS ENERGY [] AIR SYSTEM WATER VOLUME [m3]
January 0.00 0.00 0.00 0.709296E+09 0.00 0.00
February 0.00 0.00 0.00 0.546261E+09 0.00 0.00
March 0.00 0.00 0.00 0.438846E+09 0.00 0.00
April 0.00 0.00 0.00 0.353484E+09 0.00 0.00
May 0.00 0.00 0.00 0.411477E+09 0.00 0.00
June 0.00 0.00 0.00 0.485968E+09 0.00 0.00
July 0.00 0.00 0.00 0.552977E+09 0.00 0.00
August 0.00 0.00 0.00 0.673597E+09 0.00 0.00
September 0.00 0.00 0.00 0.465885E+09 0.00 0.00
October 0.00 0.00 0.00 0.352482E+09 0.00 0.00
November 0.00 0.00 0.00 0.413609E+09 0.00 0.00
December 0.00 0.00 0.00 0.566020E+09 0.00 0.00
             
Annual Sum or Average 0.00 0.00 0.00 0.596990E+10 0.00 0.00
Minimum of Months 0.00 0.00 0.00 0.352482E+09 0.00 0.00
Maximum of Months 0.00 0.00 0.00 0.709296E+09 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.307993E+09 0.00 0.675729E+09 0.00 0.00 0.00 0.00 0.00
February 0.278660E+09 0.00 0.299607E+09 0.00 0.00 0.00 0.00 0.00
March 0.337326E+09 9985309.73 31854623.41 0.00 0.00 0.00 0.00 0.00
April 0.293327E+09 0.282498E+09 2211181.29 0.00 0.00 0.00 0.00 0.00
May 0.322659E+09 0.108819E+10 0.00 0.00 0.00 0.00 0.00 0.00
June 0.322659E+09 0.174692E+10 0.00 0.00 0.00 0.00 0.00 0.00
July 0.293327E+09 0.230192E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.337326E+09 0.298184E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.293327E+09 0.175550E+10 0.00 0.00 0.00 0.00 0.00 0.00
October 0.307993E+09 0.590062E+09 0.00 0.00 0.00 0.00 0.00 0.00
November 0.307993E+09 81960912.47 78083918.48 0.00 0.00 0.00 0.00 0.00
December 0.293327E+09 0.00 0.334746E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.369591E+10 0.108389E+11 0.142223E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.278660E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.337326E+09 0.298184E+10 0.675729E+09 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.451635E+09 0.00 0.169613E+10 0.00 0.00 0.00 0.00 0.00
February 0.403162E+09 19540433.83 0.935097E+09 0.00 0.00 0.00 0.00 0.00
March 0.488039E+09 83127012.42 0.441312E+09 0.00 0.00 0.00 0.00 0.00
April 0.424382E+09 0.286930E+09 0.220969E+09 0.00 0.00 0.00 0.00 0.00
May 0.466820E+09 0.530036E+09 31860362.83 0.00 0.00 0.00 0.00 0.00
June 0.466820E+09 0.921572E+09 722226.09 0.00 0.00 0.00 0.00 0.00
July 0.424382E+09 0.163590E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.488039E+09 0.255238E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.424382E+09 0.161686E+10 1407440.85 0.00 0.00 0.00 0.00 0.00
October 0.445601E+09 0.623543E+09 42879871.73 0.00 0.00 0.00 0.00 0.00
November 0.445601E+09 20758440.00 0.524436E+09 0.00 0.00 0.00 0.00 0.00
December 0.424630E+09 5637787.05 0.116830E+10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.535349E+10 0.829628E+10 0.506311E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.403162E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.488039E+09 0.255238E+10 0.169613E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.213317E+09 0.00 0.102626E+10 0.00 0.00 0.00 0.00 0.00
February 0.187222E+09 0.00 0.630593E+09 0.00 0.00 0.00 0.00 0.00
March 0.218487E+09 0.00 0.266836E+09 0.00 0.00 0.00 0.00 0.00
April 0.190775E+09 94592788.73 86212490.92 0.00 0.00 0.00 0.00 0.00
May 0.212163E+09 0.295108E+09 2328121.81 0.00 0.00 0.00 0.00 0.00
June 0.218992E+09 0.702407E+09 0.00 0.00 0.00 0.00 0.00 0.00
July 0.204342E+09 0.100644E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.238557E+09 0.139230E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.199061E+09 0.650702E+09 0.00 0.00 0.00 0.00 0.00 0.00
October 0.200992E+09 0.132414E+09 17379000.58 0.00 0.00 0.00 0.00 0.00
November 0.199647E+09 0.00 0.279621E+09 0.00 0.00 0.00 0.00 0.00
December 0.195069E+09 0.00 0.693973E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.247862E+10 0.427397E+10 0.300320E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.187222E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.238557E+09 0.139230E+10 0.102626E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.273371E+09 0.00 0.192335E+10 0.00 0.00 0.00 0.00 0.00
February 0.244064E+09 0.00 0.134864E+10 0.00 0.00 0.00 0.00 0.00
March 0.286711E+09 0.00 0.702026E+09 0.00 0.00 0.00 0.00 0.00
April 0.249314E+09 47345308.75 0.262346E+09 0.00 0.00 0.00 0.00 0.00
May 0.274245E+09 0.236290E+09 5956588.96 0.00 0.00 0.00 0.00 0.00
June 0.274245E+09 0.704087E+09 0.00 0.00 0.00 0.00 0.00 0.00
July 0.249314E+09 0.121246E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.286711E+09 0.162863E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.249314E+09 0.648633E+09 0.00 0.00 0.00 0.00 0.00 0.00
October 0.261780E+09 74170918.55 54829265.11 0.00 0.00 0.00 0.00 0.00
November 0.261780E+09 0.00 0.624239E+09 0.00 0.00 0.00 0.00 0.00
December 0.251312E+09 0.00 0.139001E+10 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.316216E+10 0.455162E+10 0.631140E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.244064E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.286711E+09 0.162863E+10 0.192335E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentLoadsMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN AIR HEATING ENERGY [J] AIR SYSTEM COOLING COIL TOTAL COOLING ENERGY [J] AIR SYSTEM HEATING COIL TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL HEATING ENERGY [J] AIR SYSTEM HEAT EXCHANGER TOTAL COOLING ENERGY [J] AIR SYSTEM HUMIDIFIER TOTAL HEATING ENERGY [J] AIR SYSTEM EVAPORATIVE COOLER TOTAL COOLING ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER TOTAL COOLING ENERGY [J]
January 0.317863E+09 0.00 0.101767E+10 0.00 0.00 0.00 0.00 0.00
February 0.284705E+09 76367.91 0.633332E+09 0.00 0.00 0.00 0.00 0.00
March 0.340090E+09 3934244.10 0.269522E+09 0.00 0.00 0.00 0.00 0.00
April 0.295730E+09 0.108420E+09 91026060.26 0.00 0.00 0.00 0.00 0.00
May 0.325303E+09 0.383484E+09 184172.33 0.00 0.00 0.00 0.00 0.00
June 0.325303E+09 0.718710E+09 0.00 0.00 0.00 0.00 0.00 0.00
July 0.295730E+09 0.115592E+10 0.00 0.00 0.00 0.00 0.00 0.00
August 0.340090E+09 0.147941E+10 0.00 0.00 0.00 0.00 0.00 0.00
September 0.295730E+09 0.769720E+09 0.00 0.00 0.00 0.00 0.00 0.00
October 0.310517E+09 0.168648E+09 12589003.19 0.00 0.00 0.00 0.00 0.00
November 0.310517E+09 0.00 0.273589E+09 0.00 0.00 0.00 0.00 0.00
December 0.297143E+09 0.00 0.673933E+09 0.00 0.00 0.00 0.00 0.00
                 
Annual Sum or Average 0.373872E+10 0.478833E+10 0.297185E+10 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.284705E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.340090E+09 0.147941E+10 0.101767E+10 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.307993E+09 0.00 0.00 0.255887E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.278660E+09 0.00 0.00 0.129477E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.337326E+09 0.00 0.00 15289954.64 2271247.49 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.293327E+09 0.00 0.00 2337735.43 62975755.89 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.322659E+09 0.00 0.00 0.00 0.238400E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.322659E+09 0.00 0.00 0.00 0.376022E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.293327E+09 0.00 0.00 0.00 0.488361E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.337326E+09 0.00 0.00 0.00 0.634938E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.293327E+09 0.00 0.00 0.00 0.373979E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.307993E+09 0.00 0.00 0.00 0.130088E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.307993E+09 0.00 0.00 33256422.17 18498636.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.293327E+09 0.00 0.00 0.141516E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.369591E+10 0.00 0.00 0.577764E+09 0.232553E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.278660E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.337326E+09 0.00 0.00 0.255887E+09 0.634938E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.451635E+09 0.00 0.00 0.614915E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.403162E+09 0.00 0.00 0.362887E+09 4398812.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.488039E+09 0.00 0.00 0.156457E+09 18659916.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.424382E+09 0.00 0.00 76817470.10 64607448.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.466820E+09 0.00 0.00 10857323.94 0.118637E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.466820E+09 0.00 0.00 243723.59 0.205808E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.424382E+09 0.00 0.00 0.00 0.362674E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.488039E+09 0.00 0.00 0.00 0.566084E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.424382E+09 0.00 0.00 485003.11 0.346118E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.445601E+09 0.00 0.00 14562961.53 0.135295E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.445601E+09 0.00 0.00 0.190022E+09 4711033.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.424630E+09 0.00 0.00 0.435929E+09 1279713.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.535349E+10 0.00 0.00 0.186318E+10 0.182827E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.403162E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.488039E+09 0.00 0.00 0.614915E+09 0.566084E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.213317E+09 0.00 0.00 0.383289E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.187222E+09 0.00 0.00 0.251171E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.218487E+09 0.00 0.00 95377096.83 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.190775E+09 0.00 0.00 30766366.97 21571820.04 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.212163E+09 0.00 0.00 781243.77 66071894.98 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.218992E+09 0.00 0.00 0.00 0.155520E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.204342E+09 0.00 0.00 0.00 0.222083E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.238557E+09 0.00 0.00 0.00 0.309315E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.199061E+09 0.00 0.00 0.00 0.142556E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.200992E+09 0.00 0.00 5888170.01 29566861.56 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.199647E+09 0.00 0.00 0.103433E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.195069E+09 0.00 0.00 0.266957E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.247862E+10 0.00 0.00 0.113766E+10 0.946685E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.187222E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.238557E+09 0.00 0.00 0.383289E+09 0.309315E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.273371E+09 0.00 0.00 0.656714E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.244064E+09 0.00 0.00 0.475178E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.286711E+09 0.00 0.00 0.237975E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.249314E+09 0.00 0.00 89013326.93 10983040.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.274245E+09 0.00 0.00 2021484.54 52961465.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.274245E+09 0.00 0.00 0.00 0.155635E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.249314E+09 0.00 0.00 0.00 0.265321E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.286711E+09 0.00 0.00 0.00 0.359374E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.249314E+09 0.00 0.00 0.00 0.142336E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.261780E+09 0.00 0.00 18415079.78 16602333.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.261780E+09 0.00 0.00 0.216423E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.251312E+09 0.00 0.00 0.482029E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.316216E+10 0.00 0.00 0.217777E+10 0.100321E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.244064E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.286711E+09 0.00 0.00 0.656714E+09 0.359374E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: AirLoopSystemComponentEnergyUseMonthly

For: PSZ-AC:5

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

AIR SYSTEM FAN ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL HOT WATER ENERGY [J] AIR SYSTEM COOLING COIL CHILLED WATER ENERGY [J] AIR SYSTEM DX HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM DX COOLING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL ELECTRICITY ENERGY [J] AIR SYSTEM HEATING COIL NATURAL GAS ENERGY [] AIR SYSTEM HEATING COIL STEAM ENERGY [J] AIR SYSTEM HUMIDIFIER ELECTRICITY ENERGY [J] AIR SYSTEM HUMIDIFIER NATURAL GAS ENERGY [] AIR SYSTEM EVAPORATIVE COOLER ELECTRICITY ENERGY [J] AIR SYSTEM DESICCANT DEHUMIDIFIER ELECTRICITY ENERGY [J]
January 0.317863E+09 0.00 0.00 0.391433E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
February 0.284705E+09 0.00 0.00 0.261539E+09 17623.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00
March 0.340090E+09 0.00 0.00 97856762.52 899511.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00
April 0.295730E+09 0.00 0.00 32903140.55 24850403.31 0.00 0.00 0.00 0.00 0.00 0.00 0.00
May 0.325303E+09 0.00 0.00 67262.00 86105918.03 0.00 0.00 0.00 0.00 0.00 0.00 0.00
June 0.325303E+09 0.00 0.00 0.00 0.160665E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
July 0.295730E+09 0.00 0.00 0.00 0.257247E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
August 0.340090E+09 0.00 0.00 0.00 0.333508E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
September 0.295730E+09 0.00 0.00 0.00 0.170155E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00
October 0.310517E+09 0.00 0.00 4279553.91 37685481.52 0.00 0.00 0.00 0.00 0.00 0.00 0.00
November 0.310517E+09 0.00 0.00 0.103092E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
December 0.297143E+09 0.00 0.00 0.268877E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                         
Annual Sum or Average 0.373872E+10 0.00 0.00 0.116005E+10 0.107113E+10 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Minimum of Months 0.284705E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Maximum of Months 0.340090E+09 0.00 0.00 0.391433E+09 0.333508E+09 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: CORE_ZN

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.119619E+10 0.00 0.00 0.00 0.00 0.425301E+09 0.00 0.00 0.17
February 0.123474E+10 0.00 0.00 0.00 0.00 0.184091E+09 0.00 0.00 0.18
March 0.153615E+10 0.00 0.00 102930.24 0.00 18546582.77 73144833.77 0.00 0.19
April 0.860503E+09 0.00 0.00 1433839.80 0.00 0.00 0.401930E+09 0.00 0.17
May 0.187233E+09 0.00 0.00 5520760.55 0.00 0.00 0.948066E+09 0.00 0.18
June 80866184.12 6192.52 0.00 6892680.24 1431.92 0.00 0.794457E+09 0.00 0.19
July 30606075.75 15166330.47 0.00 7965263.93 1171605.00 0.00 0.446268E+09 0.00 0.17
August 27238396.57 43558436.74 0.00 7690015.38 3766136.26 0.00 0.353760E+09 0.00 0.19
September 62651459.04 71501.62 0.00 6417799.19 0.00 0.00 0.654739E+09 0.00 0.17
October 0.428327E+09 0.00 0.00 2865187.64 0.00 0.00 0.877834E+09 0.00 0.18
November 0.117900E+10 0.00 0.00 482332.89 0.00 30494784.95 0.336992E+09 0.00 0.18
December 0.134376E+10 0.00 0.00 0.00 0.00 0.216116E+09 0.00 0.00 0.17
                   
Annual Sum or Average 0.816726E+10 58802461.36 0.00 39370809.87 4939173.18 0.874549E+09 0.488719E+10 0.00 0.18
Minimum of Months 27238396.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.17
Maximum of Months 0.153615E+10 43558436.74 0.00 7965263.93 3766136.26 0.425301E+09 0.948066E+09 0.00 0.19



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_1

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 0.199740E+09 0.00 0.00 0.00 0.00 0.715584E+09 0.00 0.00 0.17
February 0.303080E+09 0.00 0.00 99215.72 0.00 0.439370E+09 48301619.67 0.00 0.18
March 0.543319E+09 0.00 0.00 372159.74 0.00 0.195035E+09 0.111733E+09 0.00 0.19
April 0.390462E+09 2407223.26 0.00 883739.06 62294.45 0.107777E+09 0.145826E+09 0.00 0.17
May 0.296541E+09 933184.72 0.00 1953356.30 30463.45 28581462.91 0.282425E+09 0.00 0.18
June 0.161575E+09 755417.00 0.00 3026500.52 189889.43 388188.04 0.323708E+09 0.00 0.19
July 59643702.77 26156895.35 0.00 4368308.82 2290753.29 0.00 0.199227E+09 0.00 0.17
August 42954427.44 76829767.00 0.00 4213174.18 5652814.54 0.00 0.172009E+09 0.00 0.19
September 0.116474E+09 10666678.14 0.00 4429639.26 102473.66 1840945.51 0.287826E+09 0.00 0.17
October 0.375633E+09 0.00 0.00 2467439.89 0.00 29907353.24 0.286517E+09 0.00 0.18
November 0.490101E+09 0.00 0.00 108861.83 0.00 0.277844E+09 59268412.11 0.00 0.18
December 0.330592E+09 0.00 0.00 37360.11 0.00 0.527068E+09 18730309.05 0.00 0.17
                   
Annual Sum or Average 0.331012E+10 0.117749E+09 0.00 21959755.44 8328688.82 0.232340E+10 0.193557E+10 0.00 0.18
Minimum of Months 42954427.44 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.17
Maximum of Months 0.543319E+09 76829767.00 0.00 4429639.26 5652814.54 0.715584E+09 0.323708E+09 0.00 0.19



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_2

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 24819137.09 0.00 0.00 0.00 0.00 0.401899E+09 0.00 0.00 0.13
February 96695545.70 0.00 0.00 0.00 0.00 0.261134E+09 0.00 0.00 0.13
March 0.247504E+09 0.00 0.00 0.00 0.00 0.131861E+09 0.00 0.00 0.14
April 0.199636E+09 1114785.74 0.00 383738.07 30096.29 45345473.62 54881052.67 0.00 0.13
May 0.132582E+09 620540.14 0.00 1337009.76 71476.58 1301728.01 0.153455E+09 0.00 0.14
June 46029871.94 437378.54 0.00 2872803.84 92110.90 0.00 0.181644E+09 0.00 0.15
July 16720158.76 16646774.10 0.00 3030926.41 1671842.80 0.00 0.102229E+09 0.00 0.14
August 12163636.91 42594357.60 0.00 2798079.41 3692531.61 0.00 83752675.18 0.00 0.16
September 54926577.30 5021353.25 0.00 2164516.08 62362.15 0.00 0.139395E+09 0.00 0.14
October 0.217113E+09 0.00 0.00 606086.46 0.00 10195665.15 93011319.61 0.00 0.13
November 0.197526E+09 0.00 0.00 0.00 0.00 0.174346E+09 0.00 0.00 0.14
December 65261819.06 0.00 0.00 0.00 0.00 0.338694E+09 0.00 0.00 0.13
                   
Annual Sum or Average 0.131098E+10 66435189.38 0.00 13193160.04 5620420.33 0.136478E+10 0.808369E+09 0.00 0.14
Minimum of Months 12163636.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.13
Maximum of Months 0.247504E+09 42594357.60 0.00 3030926.41 3692531.61 0.401899E+09 0.181644E+09 0.00 0.16



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_3

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 42936587.98 0.00 0.00 0.00 0.00 0.904866E+09 0.00 0.00 0.17
February 0.149398E+09 0.00 0.00 0.00 0.00 0.648326E+09 0.00 0.00 0.18
March 0.466196E+09 0.00 0.00 0.00 0.00 0.375955E+09 0.00 0.00 0.19
April 0.499673E+09 962287.42 0.00 111993.37 17878.24 0.123715E+09 20080660.51 0.00 0.17
May 0.402675E+09 451344.31 0.00 1016352.35 37697.51 2437039.70 0.246368E+09 0.00 0.18
June 0.150139E+09 313494.05 0.00 2819202.05 119186.49 0.00 0.375895E+09 0.00 0.19
July 41970532.93 20870519.23 0.00 3952896.78 2476113.90 0.00 0.235954E+09 0.00 0.17
August 33191620.53 58310426.83 0.00 3506927.70 5527838.18 0.00 0.201278E+09 0.00 0.19
September 0.156899E+09 1631277.27 0.00 2222776.15 8593.91 0.00 0.304704E+09 0.00 0.17
October 0.577154E+09 0.00 0.00 333107.14 0.00 26877839.41 0.103124E+09 0.00 0.18
November 0.464059E+09 0.00 0.00 0.00 0.00 0.378365E+09 0.00 0.00 0.18
December 0.159742E+09 0.00 0.00 0.00 0.00 0.737423E+09 0.00 0.00 0.17
                   
Annual Sum or Average 0.314404E+10 82539349.11 0.00 13963255.54 8187308.23 0.319797E+10 0.148740E+10 0.00 0.18
Minimum of Months 33191620.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.17
Maximum of Months 0.577154E+09 58310426.83 0.00 3952896.78 5527838.18 0.904866E+09 0.375895E+09 0.00 0.19



Table of Contents

Report: MechanicalVentilationLoadsMonthly

For: PERIMETER_ZN_4

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

ZONE MECHANICAL VENTILATION NO LOAD HEAT REMOVAL ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD INCREASE DUE TO OVERHEATING ENERGY [J] ZONE MECHANICAL VENTILATION COOLING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION NO LOAD HEAT ADDITION ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD INCREASE DUE TO OVERCOOLING ENERGY [J] ZONE MECHANICAL VENTILATION HEATING LOAD DECREASE ENERGY [J] ZONE MECHANICAL VENTILATION AIR CHANGES PER HOUR [ach]
January 56443825.38 0.00 0.00 0.00 0.00 0.501682E+09 0.00 0.00 0.17
February 0.132597E+09 0.00 0.00 0.00 0.00 0.341911E+09 0.00 0.00 0.18
March 0.334636E+09 0.00 0.00 25136.26 0.00 0.167119E+09 9536629.37 0.00 0.19
April 0.284717E+09 1122898.13 0.00 298604.93 28825.98 59543039.24 51933600.00 0.00 0.17
May 0.168297E+09 586430.25 0.00 1350325.70 61235.12 0.00 0.217952E+09 0.00 0.18
June 61190037.50 502367.92 0.00 2303749.67 63945.69 0.00 0.244319E+09 0.00 0.19
July 14841164.75 17028384.29 0.00 2993690.55 1347829.53 0.00 0.139150E+09 0.00 0.17
August 14730776.66 43857932.79 0.00 2538287.49 3092408.01 0.00 0.111076E+09 0.00 0.19
September 57604235.48 3941462.41 0.00 2012873.47 109485.32 0.00 0.200302E+09 0.00 0.17
October 0.296806E+09 0.00 0.00 633246.69 0.00 8726981.26 0.127270E+09 0.00 0.18
November 0.297407E+09 0.00 0.00 300.14 0.00 0.205741E+09 1185054.57 0.00 0.18
December 0.125459E+09 0.00 0.00 0.00 0.00 0.403693E+09 0.00 0.00 0.17
                   
Annual Sum or Average 0.184473E+10 67039475.79 0.00 12156214.88 4703729.64 0.168842E+10 0.110272E+10 0.00 0.18
Minimum of Months 14730776.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.17
Maximum of Months 0.334636E+09 43857932.79 0.00 2993690.55 3092408.01 0.501682E+09 0.244319E+09 0.00 0.19



Table of Contents

Report: HeatEmissionsReportMonthly

For: Environment

Timestamp: 2023-10-16 08:27:23

Custom Monthly Report

SITE TOTAL SURFACE HEAT EMISSION TO AIR [J] SITE TOTAL ZONE EXFILTRATION HEAT LOSS [J] SITE TOTAL ZONE EXHAUST AIR HEAT LOSS [J] AIR SYSTEM RELIEF AIR TOTAL HEAT LOSS ENERGY [J] HVAC SYSTEM TOTAL HEAT REJECTION ENERGY [J]
January 0.583977E+10 0.124850E+10 0.00 0.450226E+10 -0.358279E+10
February 0.237274E+11 0.178291E+10 0.00 0.389848E+10 -0.197398E+10
March 0.511576E+11 0.276012E+10 0.00 0.432333E+10 -916173053.1
April 0.894414E+11 0.392050E+10 0.00 0.333580E+10 0.599340E+09
May 0.123296E+12 0.492853E+10 0.00 0.313531E+10 0.306868E+10
June 0.126659E+12 0.488981E+10 0.00 0.244870E+10 0.584687E+10
July 0.135282E+12 0.485111E+10 0.00 0.120732E+10 0.890834E+10
August 0.103300E+12 0.353742E+10 0.00 0.788244E+09 0.122378E+11
September 0.683280E+11 0.219871E+10 0.00 0.205567E+10 0.661563E+10
October 0.371243E+11 0.190941E+10 0.00 0.355234E+10 0.185354E+10
November 0.102145E+11 0.128136E+10 0.00 0.419708E+10 -920137075.1
December 0.180505E+10 0.620102E+09 0.00 0.433817E+10 -0.227137E+10
           
Annual Sum or Average 0.776174E+12 0.339285E+11 0.00 0.377827E+11 0.294657E+11
Minimum of Months 0.180505E+10 0.620102E+09 0.00 0.788244E+09 -0.358279E+10
Maximum of Months 0.135282E+12 0.492853E+10 0.00 0.450226E+10 0.122378E+11